Loading...
HomeMy WebLinkAboutB16-0831 047-150-006d LC r Ll CN BENNETT ROAD ORCHARD ORCHARD C ORCHARD AREA OF INTEREST ORCHARD zz)')y.vz OVERALL SITE PLAN NO SCALE D APN: 047-150-006 123.25± ACRES RECEIVED APR 2 2 2010 ORCHARD z ORCHARD BUTTE COUNTY DDS PROJECT DIRECTORY BU=LDINGPLANNING OWNE: CLINT MOFFITT 0 TT FARMS BENNETT ROAD CHICp CA o PERMIT EXISTING AG WELL IJUTTE COUNTY DEVELOPMENT SERVICES PROJECT ENGINEER: m + RIE DEWED SUMMIT STRUCTURAL DESIGN Cory N r fl 383 RIO UNDO AVE 0-7CODE OMPLIANCE CHICO, CA 95926 (530)592-1407 �LPROPOSED 32x90 SOLAR ARRAY t?A*cce'-D *A.+"v'g+b OI ORCHARD ORCHARD NOTE: ENGINEER OF RECORD HAS NOT VISITED THE PROPOSED N CONSTRUCTION SITE. DIMENSIONS AND LAYOUT OF EXISTING ENLARGED SITE PLAN BUILDINGS AND SITE HAS BEEN DEDUCED FROM INFORMATION PROVIDED BY THE CONTRACTOR. CONTRACTOR MUST FIELD NO SCALE " - c VERIFY PLANS AND ALL DIMENSIONS PRIOR TO CONSTRUCTION . NOTE: BUILDING,ACTUAL DIMEONS SIGNSOWN AS APPROXIMATE. ACTUAL DIMENSIONS SHALL BE AND IMMEDIATELY REPORT ANY DISCREPANCIES TO SUMMIT VERIFIED IN THE FIELD. s STRUCTURAL DESIGN. DATE BY PROPOSEDCONSTRUCTION: 32'x 90' SOLAR ARRAY CODE ANALYSIS 04/15/16 GOVERNING CODES: 2013 CBC NTS 2013(EC AU 2013 CPC 16-188 2013 CMC 2013 CFC 2013 CALIF. HEALTH & SAFETY CODE AND AMENDMENTS 2013 CAU" BUILDING ENERGY EFFICIENCY STANDARDS 2013 CALIF. BUILDING CODE CHAPTER 11 OCCUPANCY GROUP: U -AGRICULTURAL BUILDING (ELEVATED RACK MOUNTED SOLAR ARRAY) OCCUPANCY SEPARATION: NONE ALLOWABLE HEIGHT AND BUILDING AREAS (TABLE 0102.1 CBC APPENDIX C) ALLOWABLE AREA: 181000 S.F. ACTUAL FLOOR AREA: 2,880 S.F. TOTAL ALLOWABLE STORY/HEIGHT: 2/55' ACTUAL STORY/HEIGHT: 1/17' CONSTRUCTION TYPE: TYPE 11B FIRE -RESISTANCE RATINGS: NONE EXTERIOR WALL SEPARATION: NONE RATED CONSTRUCNON: CHAPTER 7 PROJECTIONS: NON -RATED (SECNON 704.2) OPENINGS: UNLIMITED UNPROTECTED (TABLE 704.8) AUTOMATIC SPRINKLER: NONE NUMBER OF EXIT REO'D:1 LAE 6:>P �N cr Z LLU r O LLU w LL Ou Ocf Q O0 Z aZ QZ �w Om CA W V REVISIONS: I DATE: 04/15/16 SCALE: NTS DRAWN BY: AU JOB NUMBER: 16-188 SHEET: Al GENERAL STRUCTURAL NOTES 1. GENERAL 4. METAL FRAMING A) ALL WORK SHALL CONFORM TO THE 2013 CBC AND ALL APPLICABLE LOCAL CODES. B) THE ENGINEER (SUMMIT STRUCTURAL DESIGN) HAS PROVIDED AND IS RESPONSIBLE FOR SPECIFIC STRUCTURAL ITEMS ONLY. ALL OTHER REQUIREMENTS OF THE BUILDING CODE INCLUDING WATERPROOFING, FIREPROOFING, DRAINAGE, HANDICAP ACCESSIBILITY, EGRESS REQUIREMENTS, PARKING, AND ALL OTHER DESIGN REQUIREMENTS NOT SPECIFICALLY SHOWN IN THE STRUCTURAL DESIGN CALCULATIONS, ARE THE RESPONSIBILITY OF THE CONTRACTOR OR OWNER. SHOULD ANY CHANGES BE MADE FROM THE DESIGN AS SPECIFIED IN THESE DOCUMENTS WITHOUT THE WRITTEN APPROVAL FROM THE ENGINEER, THEN THE ENGINEER WILL ASSUME NO RESPONSIBILITY FOR ANY ELEMENT OR SYSTEM OF THE STRUCTURE. C) THE DRAWINGS AND CALCULATIONS REPRESENT THE FINISHED STRUCTURE, AND, UNLESS SPECIFICALLY NOTED OTHERWISE, DO NOT SHOW THE METHOD OF CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR THE METHOD OF CONSTRUCTION, AND SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE PUBLIC, CONSTRUCTION WORKERS, AND THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE FORMING, SHORING, BRACING, SCAFFOLDING, ETCETERA. D) IF A PARTICULAR FEATURE OF CONSTRUCTION IS NOT FULLY SHOWN ON THE DRAWINGS OR IN THE CALCULATIONS, THEN IT SHALL BE CONSTRUCTED IN THE SAME CHARACTER AS SIMILAR CONDITIONS THAT ARE SHOWN ON THE DESIGN DOCUMENTS. E) ANY CONDITIONS NOTED AS EXISTING MUST BE FIELD VERIFIED BY THE CONTRACTOR, AND ANY DISCREPANCIES MUST BE BROUGHT TO THE ATTENTION OF THE ENGINEER WITHOUT PROCEEDING WITH CONSTRUCTION PRIOR TO THE REVIEW OF THE ENGINEER. F) ALL WATERPROOFING AND FLASHING (ROOFS, FOUNDATIONS, GARAGE FLOORS, ETC...) IS THE RESPONSIBILITY OF THE CONTRACTOR OR OWNER. G) SHOP DRAWINGS: SHOP DRAWINGS ARE SUPERCEDED BY THE STRUCTURAL DRAWINGS UNDER ALL CIRCUMSTANCES. THE GENERAL CONTRACTOR SHALL VERIFY THAT ALL CONSTRUCTION IS IN FULL AGREEMENT WITH THE LATEST STRUCTURAL DRAWINGS. REVIEW OF SHOP DRAWINGS BY THE ENGINEER OF RECORD DOES NOT GUARANTEE IN ANY WAY THE THE SHOP DRAWINGS ARE CORRECT, NOR DOES IT INFER THAT THEY SUPERCEDE THE STRUCTURAL DRAWINGS. H) SPECIAL INSPECTION: SPECIAL INSPECTION PER SECTION 1701 OF THE CBC SHALL BE PROVIDED FOR THE FOLLOWING TYPES OF CONSTRUCTION: WELDING OF STRUCTURAL OR REINFORCING STEEL THE SPECIAL INSPECTOR SHALL BE ACCEPTABLE TO THE STRUCTURAL ENGINEER AND BUILDING DEPARTMENT, SHALL BE ICBO QUALIFIED, AND THEIR EXPERIENCE SHALL BE COMMENSURATE WITH THIS TYPE OF PROJECT. 2. SITE WORK / FOUNDATIONS A) ASSUMED MAXIMUM SOIL BEARING = 1500 PSF PER CBC TABLE 1806.2 (NO SOILS REPORT PROVIDED). B) BUILDING SITE IS ASSUMED TO BE DRAINED AND FREE OF CLAY OR EXPANSIVE SOIL. ENGINEER HAS NOT MADE A GEOTECHNICAL REVIEW OF SITE, ANY OTHER CONDITIONS ENCOUNTERED MUST BE BROUGHT TO THE ATTENTION OF THE ENGINEER. C) THESE CALCULATIONS ASSUME STABLE, UNDISTURBED SOILS AND LEVEL OR STEPPED FOOTINGS. ANY OTHER CONDITIONS SHOULD BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO THE CONSTRUCTION OF THE FOUNDATIONS. D) BOTTOM OF ALL FOUNDATION TRENCHES SHALL BE CLEAN AND LEVEL. E) ALL FINISHED GRADE SHALL SLOPE AT A MINIMUM SLOPE OF 5% AWAY FROM ALL FOUNDATIONS A MINIMUM OF 10 FEET HORIZONTAL. F) FOUNDATIONS SHALL NOT BE SCALED FROM PLAN OR DETAIL DRAWINGS. G) FILL MATERIAL SHALL BE FREE FROM DEBRIS, VEGETATION, AND OTHER FOREIGN SUBSTANCES. 3. CONCRETE / REINFORCING A) CONCRETE SHALL HAVE A MINIMUM 28 DAY STRENGTH OF 3,000 PSI U.N.O. (DESIGN BASED ON 2500 PSI) B) ALL CEMENT USED SHALL CONFORM TO ASTM C-150 AND SHALL BE TYPE II OR TYPE III LOW ALKALI. C) AGGREGATE SHALL CONFORM TO ASTM C-33 AND SHALL NOT CONTAIN MATERIALS WHICH ARE ALKALI REACTIVE AS DETERMINED BY ASTM C-227, 289, AND 295. IF TEST DATA IS UNAVAILABLE IN REGARDS TO ALKALI REACTIVE MATERIALS, PROVIDE CEMENT WITH A MAXIMUM ALKALI CONTENT LESS THAN 0.45% BY WEIGHT. D) CONCRETE EXPOSED TO FREEZING OR THAWING SHALL BE PROTECTED IN ACCORDANCE TO THE LATEST EDITION OF THE ACI 318. E) REINFORCEMENT COVER SHALL BE AS FOLLOWS: CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO SOIL: 3" CONCRETE WITH SOIL OR WEATHER EXPOSURE: #5 BARS AND SMALLER 1 %" #6 BARS AND LARGER 2" CONCRETE WITHOUT SOIL OR WEATHER EXPOSURE: 3/4" F) REINFORCEMENT SHALL BE GRADE 60 PER ASTM A615 U.N.O. LAP BOTTOM REINFORCING (60) BAR DIAMETERS U.N.O. AND LAP TOP REINFORCING, PLACED ABOVE 12" OF CONCRETE OR MORE, (80) BAR DIAMETERS U.N.O. G) #5 AND LARGER REBAR SHALL NOT BE RE-BENT. H) ALL REINFORCING STEEL AND ANCHOR BOLTS SHALL BE ACCURATELY LOCATED AND ADEQUATELY SECURED IN POSITION BEFORE AND DURING CONCRETE PLACEMENT. A) ALL METAL FRAMING SHALL BE DETAILED, FABRICATED AND ERECTED IN ACCORDANCE WITH THE LATEST EDITION OF THE AMERICAN IRON AND STEEL INSTITUTES "SPECIFICATION FOR THE DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS." 4-1 MATERIALS: A) GALVANIZED STEEL SHALL MEET THE MINIMUM REQUIREMENTS OF ASTM A446 GRADE D (FY=50 KSI) FOR 12,14 AND 16 GAGE, AND ASTM A446 GRADE A (FY=33KS1) FOR 18 GAGE AND LIGHTER. B) METAL FRAMING SHALL BE OF THE TYPE, SIZE AND GAGE AS SHOWN ON THE PLANS AND SHALL NOT BE PUNCHED UNLESS SPECIFICALLY NOTED ON PLAN. C) ACCESSORIES: PROVIDE ALL ACCESSORIES INCLUDING, BUT NOT LIMITED TO TRACKS, CLIPS, BRIDGING, BLOCKING, STIFFENERS, FASTENERS, ANCHORS, RESILIENT CHANNELS AND OTHER ITEMS REQUIRED FOR A COMPLETE AND PROPER INSTALLATION. D) CONNECTIONS: ALL FASTENING OF COMPONENTS SHALL BE WITH SELF -DRILLING SCREWS OR WELDING AS SHOWN ON THE STRUCTURAL DRAWINGS. ALL WELDS OF GALVANIZED STEEL SHALL BE TOUCHED UP WITH ZINC -RICH PAINT. E) WELDING ELECTRODES: SHALL BE E60XX FOR 18 GAGE AND LIGHTER AND E70XX FOR 16 GAGE AND HEAVIER. 4-2 FABRICATION: A) TYPICAL DETAILS: FOR METAL FRAMING DETAILS, SEE SHEET S2. B) WELDING: ALL WELDING TO BE PERFORMED BY CERTIFIED LIGHT GAGE WELDERS, CERTIFIED FOR ALL APPROPRIATE DIRECTION, PER THE LATEST EDITION OF AWS D1.2. 4-3 INSTALLATION: A) DELIVERY: ALL METAL FRAMING ELEMENTS SHALL BE DELIVERED TO THE JOB SITE FREE OF DISTORTIONS OR DAMAGE OF ANY KIND. B) BRACING: TEMPORARY BRACING SHALL BE DESIGNED AND PROVIDED BY THE CONTRACTOR AS REQUIRED UNTIL ERECTION IS COMPLETED. 5. STRUCTURAL STEEL A) STRUCTURAL STEEL: ROLLED STEEL SHAPES, PLATES, AND BARS SHALL CONFORM TO ASTM A-36. WIDE FLANGE SHAPES SHALL CONFORM TO ASTM A-992. B) STRUCTURAL TUBES: STRUCTURAL TUBES SHALL CONFORM TO ASTM A-500 GRADE B. C) ALL WELDING SHALL BE ELECTRIC ARC WELDING, AND SHALL BE PERFORMED ONLY BY EXPERIENCED, QUALIFIED WELDERS. ELECTRODES SHALL BE E60 XX FOR METAL DECK AND E70 XX OTHERWISE, UNLESS SPECIFICALLY NOTED OTHERWISE. WELDING SHALL CONFORM TO AWS D1.1. D) UNSPECIFIED WELDS: WELDS NOT SPECIFIED SHALL BE CONTINUOUS FILLET WELDS. WELD SIZE SHALL BE PER AISC SPECIFICATIONS FOR THE THICKER PART OF THE JOINT. E) ALL STEEL SHALL BE SHOP PAINTED, UNLESS ENCASED IN CONCRETE, GROUTED MASONRY, OR SPRAYED FIREPROOFING, UNLESS SPECIFICALLY NOTED ON THE DRAWINGS. F) BOLTS AND LAG SCREWS: BOLTS AND LAG SCREWS SHALL BE ASTM A-307 U.N.O. AND a. PROVIDED NEW AND WITHOUT EXCESSIVE RUST. RECEIVED 6. DESIGN LOADS APR 2 2 2016 A) THE STRUCTURE HAS BEEN DESIGNED FOR THE FOLLOWING CRITERIA PER CBC CHAPTER 16, DIVISIONS I, II, III, AND IV U.N.O.: BUTTE COUNTY Dos 130L"UINC * PLANNIR':G B) SEISMIC: t%Ilk' � �I SEISMIC IMPORTANCE FACTOR: 1 1, I l�' V MAPPED SPECTAL RESPONSE ACCELERATIONS: Ss = 0.628, S1= 0.286 PERMIT# SEISMIC SITE CLASS: D '3U 1 I E COUNTY DEVELOPMENT SERVICES SPECTRAL RESPONSE COEFFICIENTS: SDS = 0.543, SDI = 0.348, Cs = 0.27 REVIEWED FOR !SDE�OMPLIANCE SEISMIC DESIGN CATEGORY: D BASIC SEISMIC -FORCE -RESISTING SYSTEM: INVERTED PENDULUM TYPE STRUCTURE DATE S (I BY SEISMIC BASE SHEAR: 6.0 KIPS RESPONSE MODIFICATION FACTOR: R = 2 ANALYSIS PROCEDURE USED: EQUIVALENT STATIC FORCE PROCEDURE C) WIND: WIND SPEED: 110 MPH WIND EXPOSURE: C F__L_c_)a'p ZoN G� ANY Irzmtr rZ-eC-,?U l aJ25_ A 9Q l(_0( N6 pOn- 11- tb ABBREVIATIONS AB ANCHOR BOLT K KIPS ADD'L ADDITIONAL L ANGLE ADJ ADJACENT LLH LONG LEG HORIZ. ALT ALTERNATE LLV LONG LEG VERT. ARCH ARCHITECTURAL LONG LONGITUDINAL BLDG BUILDING LSL LONG SLOTTED HOLE BLKG BLOCKING LVL LAMINATED VENEER LUMBER BM BEAM MAX MAXIMUM BOTT (B) BOTTOM MB MACHINE BOLTS BTF BEAT TO FIT MECH MECHANICAL BTWN BETWEEN MFR MANUFACTURER CB CARRIAGE BOLTS MIN MINIMUM CCJ CONTROL JOINT MISC. MISCELLANEOUS CIP CAST -IN-PLACE CONCRETE MTL METAL CJ CONSTRUCTION JOINT (N) NEW CLR CLEAR NS NEAR SIDE CMU CONCRETE MASONRY UNITS NSA NELSON STUD ANCHOR COL COLUMN NTS NOT TO SCALE CONC CONCRETE OC ON CENTER CONN CONNECTION OD OUTSIDE DIAMETER CONSTR CONSTRUCTION OH OPPOSITE HAND CONT CONTINUOUS OPNG OPENING CONTR CONTRACTOR OVS OVERSIZE ROUND HOLE CP COMPLETE PENETRATION PDF POWDER DRIVEN FASTENER CTR CENTER PERP PERPENDICULAR CTSK COUNTERSINK PL PLATE DBL DOUBLE PLWD PLYWOOD DF DOUGLAS FIR PLCS PLACES DF -L DOUGLAS FIR - LARCH PP PARTIAL PENETRATION DIA DIAMETER PT PRESSURE TREATED DJ DOUBLE JOIST P/C PRECAST CONCRETE EA EACH P/T POST -TENSIONED EF EACH FACE REINF REINFORCEMENT EL ELEVATION (DATUM) REQ'D REQUIRED ELEV ELEVATION (VIEW) OR ELEVATOR SC SLIP CRITICAL EN EDGE NAILING SEOR STRUCTURAL ENGINEER OF EQ EQUAL RECORD ES EACH SIDE SHTG SHEATHING (E) EXISTING SIM SIMILAR EXP EXPANSION SOG SLAB -ON -GRADE EXT EXTERIOR STD STANDARD EW EACH WAY STIFF STIFFENER FF FINISH FLOOR STL STEEL FIN FINISH SQ SQUARE FJ FLOOR JOIST SS STAINLESS STEEL FLR FLOOR SWS SHEAR WALL SCHEDULE FNDN FOUNDATION SYM SYMMETRICAL FOHC FREE OF HEART CENTER T&B TOP & BOTTOM FOS FACE OF STUD TO(P) TOP OF (PLYWOOD) FS FAR SIDE TOC TOP -OF -CONCRETE FTG FOOTING TOF TOP -OF -FOOTING GA GAUGE TOS TOP -OF -STEEL GALV GALVANIZED TOW TOP -OF -WALL GLB GLUE -LAM BEAM TN TOE NAIL HDG HOT DIPPED GALVANIZED TYP TYPICAL HDR HEADER LINO UNLESS NOTED OTHERWISE HGR HANGER (SIMPSON) VERT VERTICAL HORIZ HORIZONTAL WP WORKPOINT ID INSIDE DIAMETER WWF WELDED WIRE FABRIC INT INTERIOR W/ WITH JST JOIST W/O WITHOUT JT JOINT NOTE: PRIOR TO CONSTRUCTION AND ORDERING MATERIALS CONTRACTOR SHALL VERIFY ALL DIMENSIONS SHOWN AND COORDINATE ALL DIMENSIONS WITH SITE CONDITIONS. CONTACT SUMMIT STRUCTURAL DESIGN WITH ANY DISCREPANCIES. 6�w�,,�-� �novp : tic SHEET INDEX SO STRUCTURAL NOTES AND ABBREVIATIONS S1 FOUNDATION PLAN AND ROOF PLAN S2 TYPICAL DETAILS AND SECTION Q�pFESS/pN9 "-�No. 75688' cc * E 6/ 0/16 J� CIVo- gTFOF cwU 4/28/16 THESE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE ONLY WITH THE ATTACHED STRUCTURAL CALCULATIONS 383 Rio Lindo Ave. Suite 200 Chico, CA 95926 P. 530.592.4407 SummitChico.com W V 1 � W f— Q U U 1 O~ ~ Vi z W D 00 U =W Q Nr or -m re Q m D 0 N Q c 0 UG cr- w�_ QL LL- W �z LL W (� LL CO V10 REVISIONS: DATE: 4/28/16 SCALE: NTS DRAWN BY: RKB JOB NUMBER: 16-151 SHEET: so 2'-3„ 281-61) 12x3.5 C12 U-) N N xr 12x3.5 Z12 U-) LO C� q- Nx x 04 U CJ 12x3.5 Z12 L0 L0 NN '-d- x x C,4 C14 12x3.5 Z12 3 go,—O,, _A 61, --A 28'-619 28P -69p 20-3, �No. 75688' E 6 0/16 ROOF LOW SIDE 12x3.5 Cl 21 V 12x3.5 C12 OF CAO U-) C� TYP C'� I- Ci -q- xl- �ps - 4/28/16 2 Ty I - — - N THESE PLANS HAVE BEEN REVIEWED 12x3.5 Z12 TYP S2 FOR COMPLIANCE ONLY WITH THE 12x3.5 Zl 2 ATTACHED STRUCTURAL CALCULATIONS U') LO U-) Ln fIll C� q- NIq- N1,4- III x C-4 12x3.5 Z12 x 04x 1 0 X* 0, CV q- x C14 - — NU 00 12x3.5 Z12 Lj m U-) ww00- Lr) NU N x C14 0 x Clq4 12x3.5 x Cq bi VU 12x3.5 Z12 C%4 D LO Z Ln x C,j I Lr) C� I- x 04 L0 C� U.J::) 00 12x3.5 Zl 2 12x3.5 C12 Lr) Nft' LO NN U U) < x SIDE x x C,4 C*lq4 x 04 9'- 6 ", TYP < i 12x3.5 Zl 2 AND < LLI U-) MAXIMUM LO r) 0,i PSF. x 04 PER 12/S2, x 04 ULINE ROOF PLAN 12x3.5 C12 TYP \BLOCKING, TYP 3 go,—O,, _A 61, --A 28'-619 28P -69p 20-3, �No. 75688' E 6 0/16 ROOF LOW SIDE 12x3.5 Cl 21 V 12x3.5 C12 OF CAO U-) C� TYP C'� I- Ci -q- xl- �ps - 4/28/16 2 Ty I - — - N THESE PLANS HAVE BEEN REVIEWED 12x3.5 Z12 TYP S2 FOR COMPLIANCE ONLY WITH THE 12x3.5 Zl 2 ATTACHED STRUCTURAL CALCULATIONS U') LO U-) Ln fIll C� q- NIq- N1,4- III NOTE: OBTAIN WRITTEN SOLAR PANEL LAYOUT REVIEW LETTER FROM ENGINEER OF RECORD PRIOR TO INSTALLATION OF SOLAR RACKING. PBR PANEL, 26 GA. ROOFING OR EQUIVALENT WITH #12 SCREW TO EACH PURLIN AT 12" O.C. AND #14 SCREW AT ALL PANEL EDGES AT SPACING PER MFR. INSTALL ALL FASTENERS PER MFR INSTRUCTIONS. ..)(-ALL: 1/4 It =11-0" PANELS SHALL SPAN (/-) BAYSMIN. 2 3 4 go$ -001 1 29-30*. 28'-61f 289-611 280-619 21-3 pw r - - - - - - - ..ROOF ..LOW I SI D E . . . . . ... ..... . ... .. ... ... .. ... .......... .......... ...... ..... .......... .... . . .......... . . .. . ..... . ...... . ....... ...... ........ . ....... ......... ........ ..... .. .......... .......... ..... . .. .......... .... . . ..... 7 : 5-6" SQ. X 3'- 9 " THICK 7 I-------- - - - -- FOOTING ------'J ---�6'-6" SQ. X 4'-,3" THICK PER 1/S2I I ---�\5-6" SO. X S-9" THICK J\6'-6" SQ. X 4'-3" THICK i FOOTING PER 1/S2 FOOTING PER 1/S2 I I I FOOTING PER 1/S2 I NOTE: PRIOR TO CONSTRUCTION AND ORDERING MATERIALS CONTRACTOR SHALL VERIFY ALL DIMENSIONS SHOWN AND COORDINATE ALL DIMENSIONS WITH SITE CONDITIONS. CONTACT SUMMIT STRUCTURAL DESIGN WITH ANY DISCREPANCIES. 5-6" SO. X 3'-9" THICK -VU IL -1114L kil I \ %-.1 \./ I \);ll ABOVE, TYP FOUNDATION PLAN SCALE: 1/4" = V-0" --0 PERMIT # BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR CODE COMPLIANCE DATE. - WN pp - 383 Rio Lindo Ave. Suite 200 Chico, CA 95926 P. 530.592.4407 SummitChico.com z x C-4 12x3.5 Z12 x 04x 1 x - — 7— Ll. U U-) U') x 0 Lij 1 2x3.5 Z12 NU x C14 C\J C',I 12x3.5 Z12 VU C%4 D Z L0 C� Lr) C� I- 12x3.5 L0 C� U.J::) 00 12x3.5 C12 Lr) Nft' < U U) < x 04 SIDE x C,4 W:D x 04 9'- 6 ", TYP < i x 04 AND < LLI ATTACHMENT BY OTHERS. V MAXIMUM < r) TOTAL ADDED LOAD = 3 PSF. SI LAP ZEE PURLINS 6'-3 1/2" PER 12/S2, TYP THIS ULINE ROOF PLAN Cr- < TYP L -L 12x3.5 Z12 0 12x3.5 Z12 CO 0 0 z D 0 Lr) C� LL L0 C-� 00 Z!! pr) - S2 0 L0 Ln < 0 x x N x TYP 't -J x x 04 U) — Ld 3]m 12x,3.5 Z12 00 -3: 0 < LL. 12x3.5 Zl 2 IL Ld w w En Of C-4 00 ni x 0 LO C� I- LO C� X S SHALL NOTE: ALL PURLINS Ln C'� "t - 0 V) LO C'� x Cn 0 C'4 U 04 U BE ASTM 572, GRADE 55,0 x 12 GAGE U.N.O. 12x3.5 Zl 2 Li 0 12x3.5 Zl 2 < LnLn C� C'� SIM S2 C� Ln Nx TYP CN 12x3.5 Zl 2 12x3.5 Z12 1 Inii iE NOTE: OBTAIN WRITTEN SOLAR PANEL LAYOUT REVIEW LETTER FROM ENGINEER OF RECORD PRIOR TO INSTALLATION OF SOLAR RACKING. PBR PANEL, 26 GA. ROOFING OR EQUIVALENT WITH #12 SCREW TO EACH PURLIN AT 12" O.C. AND #14 SCREW AT ALL PANEL EDGES AT SPACING PER MFR. INSTALL ALL FASTENERS PER MFR INSTRUCTIONS. ..)(-ALL: 1/4 It =11-0" PANELS SHALL SPAN (/-) BAYSMIN. 2 3 4 go$ -001 1 29-30*. 28'-61f 289-611 280-619 21-3 pw r - - - - - - - ..ROOF ..LOW I SI D E . . . . . ... ..... . ... .. ... ... .. ... .......... .......... ...... ..... .......... .... . . .......... . . .. . ..... . ...... . ....... ...... ........ . ....... ......... ........ ..... .. .......... .......... ..... . .. .......... .... . . ..... 7 : 5-6" SQ. X 3'- 9 " THICK 7 I-------- - - - -- FOOTING ------'J ---�6'-6" SQ. X 4'-,3" THICK PER 1/S2I I ---�\5-6" SO. X S-9" THICK J\6'-6" SQ. X 4'-3" THICK i FOOTING PER 1/S2 FOOTING PER 1/S2 I I I FOOTING PER 1/S2 I NOTE: PRIOR TO CONSTRUCTION AND ORDERING MATERIALS CONTRACTOR SHALL VERIFY ALL DIMENSIONS SHOWN AND COORDINATE ALL DIMENSIONS WITH SITE CONDITIONS. CONTACT SUMMIT STRUCTURAL DESIGN WITH ANY DISCREPANCIES. 5-6" SO. X 3'-9" THICK -VU IL -1114L kil I \ %-.1 \./ I \);ll ABOVE, TYP FOUNDATION PLAN SCALE: 1/4" = V-0" --0 PERMIT # BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR CODE COMPLIANCE DATE. - WN pp - 383 Rio Lindo Ave. Suite 200 Chico, CA 95926 P. 530.592.4407 SummitChico.com z 12x3.5 Z12 12x3.5 Z12 1 - — 7— Ll. U U-) U') x 0 Lij NU x C14 C\J C',I VU C%4 D Z 12x3.5 C12 U.J::) 00 12x3.5 C12 w 4111 < U < ROOF HIGH SIDE L W:D 9'-6", TYP 9'- 6 ", TYP < i Sim 9'- 6 TYP TYP NOTE: FLUSH MOUNT PV PANELS AND < 0 ATTACHMENT BY OTHERS. V MAXIMUM < r) TOTAL ADDED LOAD = 3 PSF. SI LAP ZEE PURLINS 6'-3 1/2" PER 12/S2, TYP THIS ULINE ROOF PLAN Cr- < TYP L -L NOTE: OBTAIN WRITTEN SOLAR PANEL LAYOUT REVIEW LETTER FROM ENGINEER OF RECORD PRIOR TO INSTALLATION OF SOLAR RACKING. PBR PANEL, 26 GA. ROOFING OR EQUIVALENT WITH #12 SCREW TO EACH PURLIN AT 12" O.C. AND #14 SCREW AT ALL PANEL EDGES AT SPACING PER MFR. INSTALL ALL FASTENERS PER MFR INSTRUCTIONS. ..)(-ALL: 1/4 It =11-0" PANELS SHALL SPAN (/-) BAYSMIN. 2 3 4 go$ -001 1 29-30*. 28'-61f 289-611 280-619 21-3 pw r - - - - - - - ..ROOF ..LOW I SI D E . . . . . ... ..... . ... .. ... ... .. ... .......... .......... ...... ..... .......... .... . . .......... . . .. . ..... . ...... . ....... ...... ........ . ....... ......... ........ ..... .. .......... .......... ..... . .. .......... .... . . ..... 7 : 5-6" SQ. X 3'- 9 " THICK 7 I-------- - - - -- FOOTING ------'J ---�6'-6" SQ. X 4'-,3" THICK PER 1/S2I I ---�\5-6" SO. X S-9" THICK J\6'-6" SQ. X 4'-3" THICK i FOOTING PER 1/S2 FOOTING PER 1/S2 I I I FOOTING PER 1/S2 I NOTE: PRIOR TO CONSTRUCTION AND ORDERING MATERIALS CONTRACTOR SHALL VERIFY ALL DIMENSIONS SHOWN AND COORDINATE ALL DIMENSIONS WITH SITE CONDITIONS. CONTACT SUMMIT STRUCTURAL DESIGN WITH ANY DISCREPANCIES. 5-6" SO. X 3'-9" THICK -VU IL -1114L kil I \ %-.1 \./ I \);ll ABOVE, TYP FOUNDATION PLAN SCALE: 1/4" = V-0" --0 PERMIT # BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR CODE COMPLIANCE DATE. - WN pp - 383 Rio Lindo Ave. Suite 200 Chico, CA 95926 P. 530.592.4407 SummitChico.com z r) Ll. 0 Lij 0 VU D Z U.J::) 00 < U < V) r 71, W:D < i co < 0 < r) 0 Z Cr- < r L -L 0 �zz Li- CO 0 0 z D 0 LL REVISIONS: DATE: 4/28/16 SCALE: AS SHOWN DRAWN BY: RKB JOB NUMBER: 16-151 SHEET: I l CENTERLINE OF BEAM SUPPORT IZEE PURLIN PER FLAN (4) 1/2- DIA. THRU BOLTS \ z(2) 1/2- DIA. .... ...... ..... ..... .... ..... ... ..... ...... ..... ._...... ..... ..... .__ ._............_............................................._ ..................... _........_.........._..._ _....._. _ .... _" " (2) 1/2- DIA. i THRU BOLTS THRU BOLTS ---,-o 9/16" DIA. HOLE*_%0 O��OBLONG HOLE, 0 TYP U.N.O. 4", TYP 0 0 ! 0 _�' 0 3/4" 35" , 35" 2"7 2" NOTES: 1.) FOR CLARITY ONLY ONE END OF ONE ZEE PURLIN IS SHOWN. 2.) SEE DETAIL 3/S2 FOR ADDITIONAL INFORMATION. NOTES: NOTES: 1.) CORROSION PROTECTION AND DRAINAGE BY OTHERS. 1.) CORROSION PROTECTION AND DRAINAGE BY OTHERS. 2.) PV PANELS AND ATTACHMENT BY OTHERS, NOT SHOWN FOR CLARITY. 2.) PV PANELS AND ATTACHMENT BY OTHERS, NOT SHOWN FOR CLARITY. NOTES: MAXIMUM TOTAL ADDED LOAD = 3 PSF MAXIMUM TOTAL ADDED LOAD = 3 PSF 1.) CORROSION PROTECTION AND DRAINAGE BY OTHERS. 1 3/4", TYP. 1 3/4" TYP. 2.) PV PANELS AND ATTACHMENT BY OTHERS, NOT SHOWN FOR CLARITY. 3/8" PLATE X 5 3/4" X 10" WITH LLV. CENTERED MAXIMUM TOTAL ADDED LOAD = 3 PSF ROOFING AND ATTACHMENT PER PLAN-, \ PURLIN PER F CONN. PER 3 TYPICAL PURLIN END SPLICE DETAIL 12 1 TYPICAL FRAME DETAIL NO SCALE FLUSH MOUNTED SOLAR PANELS AND ATTACHMENT BY OTHERS NOT SHOWN FOR CLARITY\ �<z OZQ �0 U N F- -i Z =Qt�N X UJ Li 0 <:z Q 0 Z w m J d O Z U a� a� I Q Z p U �QwU(n w 0 m 0 U U N Z Of �0� waw TYPICAL SECTION L12J NO SCALE 'BEAM PER PLAN METAL ROOFING PER P SLOPE = 1:12 RLIN PER PLAN, TYP NOTE: VERIFY STRUCTURE HEIGHTS TO FINISHED GRADE WITH OWNER PRIOR TO CONSTRUCTION POST PER PLAN, TOP OF FINISHED GRADE BY OTHERS 27'-6" NOTE: CORROSION PROTECTION, FLASHING, WATERPROOFING, WEATHER PROTECTION, AND DRAINAGE BY OTHERS. Co R PLAN SCALE: 1/4" = 1'-0" NOTES: 1.) CORROSION PROTECTION AND DRAINAGE BY OTHERS. 2.) PV PANELS AND ATTACHMENT BY OTHERS, NOT SHOWN FOR CLARITY. MAXIMUM TOTAL ADDED LOAD = 3 PSF 1 3/4", TYP. 1 3/4", TYP. PURLIN PER PLAN NOTE: PRIOR TO CONSTRUCTION AND ORDERING MATERIALS CONTRACTOR SHALL VERIFY ALL DIMENSIONS SHOWN AND COORDINATE ALL DIMENSIONS WITH SITE CONDITIONS. CONTACT SUMMIT STRUCTURAL DESIGN WITH ANY DISCREPANCIES. BLOCKING PER PLAN A PURLIN PER N PLAN BLOCKING PER 1 3/4% TYP. ROOFING AND PLAN, TYP ATTACHMENT PER PLAN o (2) 1/2" DIA. o� \ THRU BOLTS L7 1/40 1/20 GAGE X 1 Ow LENGTH, TYP. N (2) 1/2- DIA. 1/4- GAP, TYP THRU BOLTS TYPICAL PURLIN DETAIL NO SCALE ""PURLIN PER PLAN, TYP A ROOFING AND 1/4" GAP, TYP,,: ATTACHMENT PER PLAN 1, I o -\- A2" • L7 1/40 1/20 GAGE N X 10" LENGTH, TYP. (2) 1/2- DIA. THRU BOLTS TYPICAL PURLIN DETAIL NO SCALE NOTES: 1.) CORROSION PROTECTION AND DRAINAGE BY OTHERS. 2.) PV PANELS AND ATTACHMENT BY OTHERS, NOT SHOWN FOR CLARITY. MAXIMUM TOTAL ADDED LOAD = 3 PSF ROOFING AN ATTACHMEN' TYPICAL FRAME DETAIL RLIN PER PLAN WITH 1NN. PER 3/S2 SIM. ROOFING ) ATTACHME PER PLAN AND .ATE ►N NOTE: SEE 12/S2 FOR ADDITIONAL SPLICE REQUIREMENTS AT ZEE PURLINS. TYPICAL PURLIN-FRAME CONN. DETAIL NO SCALE K PER AISC, TYP PLATE 1/2" EACH SIDE A N TYP" PLATE 1" WITH (4) 7/8" DIA. BOLTS - 55 16 .— -BEAM PER PLAN /2" TP HSS POST PER PLAN CENTERED BELOW BEAM NOTE: CORROSION PROTECTION BY OTHERS. TYPICAL BEAM -COLUMN CONN. DETAIL NO SCALE S2 NO SCALE -_ LS2j NOTE: CORROSION PROTECTION AND DRAINAGE BY OTHERS. HSS PER PLAN CENTERED ON FOOTING 2 1/2 TYP BELOW AND CENTERED ON BASE PLATE BASE PLATE 1" 'X 14" SQ. (GRADE 50) WITH (4) SIMPSON PA89 ANCHORS (OR A CP EQUAL) WITH DBL NUT AND 24" MINIMUM EMBED IN FTG BELOW PEDESTAL I ( I I 2" NON -SHRINK GROUT (3000 PSI AT 1 DAY, 5000 PSI AT 28 DAYS) N �3/4" CHAMFER, TYP FINISHED UNDISTURBED 8" MAX GRADEBY NATURAL GRADE, TYP OTHERS #4 HOOPS AT 6" O.C. AND MIN WITHIN 5 I I I IOF TOP) OF PED ES " 1 1 — — I —III 1 1/2' CLR..,, TYP CLR. M s}- FOOTING I I I ( z PER PLAN II II m a a #4 TIES AT o N 1- 6 O.C., TYP II II I w w CV Z Z • • • • • • • • • • • • J 00 wi 44 AT 6" or 00 11 0 EACH WAY TOP, MID, AND BOTTOM_ • 0 0 O O Q 3/4" CHAMFER, TYP�� 11 0 EACH WAY TOP, MID, AND BOTTOM_ Q Q 3/4" CHAMFER, TYP�� (8) #5 VERTS M Q, -8 3" CLR., TYP A N EQUAL EQUAL PERMIT # i BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR OF HSS ABOVE CO E COMPLIANCE DATE,e ,ABY 1 TYPICAL SPREAD FOOTING DETAIL NO SCALE l FS ES 0 e 0 Nq ":-N o. 75688'T' * 6/ 0/16 "p CIVIL q�FOF CALF 4/28/16 THESE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE ONLY WITH THE ATTACHED STRUCTURAL CALCULATIONS IBM 383 Rio Lindo Ave. Suite 200 Chico, CA 95926 P. 530.592.4407 SummitChico.com W W �Q Q V U .� z Z W Z)O _ p0 = W U r w QCn Cn U C!1 O o Q S O N G �- z LaL. ~ V) < W z LL W Q LL 0° O U REVISIONS: DATE: 4/28/16 SCALE: AS SHOWN DRAWN BY: RKB r NUMBER: 16-151 ET: F 3 Sl�.o831