Loading...
HomeMy WebLinkAboutB16-1046 000-000-000SCOPE OF WORK GENERAiAgOTES LEGEND AqjABBREVIATIONS TABLE OF CONTENTS PAGE # DESCRIPTION • SYSTEM SIZE: 9275W DC, 760OW AC- . ALL WORK SHALL COMPLY WITH 2013 NEC; 2013 IBC, MUNICIPAL CODE, AND� SOLAR MODULES `-� — VICSE SERE ENTRANCE S � -PV-:0 1 COVER SHEET • MODULES: (35) HANWHA Q -CELLS: Q.PRO BFR - G4.1 265 , ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. RAIL PV -2.0 SITE PLAN • INVERTER(S): PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2013 NEC. PV -3.0 LAYOUT (1) ABB: UNO-7.6-TL-OUTD-S-US-A.(240V) ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2013 NEC. Mp MAIN PANEL . • RACKING: SNAPNRACK SERIES 100 UL: FLASHED L FOOT. . PHOTOVOLTAIC SYSTEM IS UNGROUNDED: NO CONDUCTORS ARE SOLIDLY PV -4.0 ELECTRICAL. SEE PEN D01. GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. -,- PV -5.0 SIGNAGE • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703,1 SP SUB -PANEL • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. STANDOFFS & RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. FOOTINGS. • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(E) AND 2012 LC PV LOAD CENTER ` I CHIMNEY -IFC 605.11.2. - k _ , - �, _ • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. • 9.15 AMPS MODULE SHORT CIRCUIT CURRENT.SM SUNRUN METER ATTIC VENT • 14.29 AMPS DERATED SHORT CIRCUIT CURRENT (690.8 (a)} 690.8 (b)). ; - M- FLUSH ATTIC VENT • , s DEDICATED PV METER 0 C PIPE VENT - - INVERTER(S) WITH � - � , - � RMETAL PIPE VENT NV _ E :... TED D _- DISCONNECT AND AFCL- 04-" =T -VENT: `' =-.;• �-,�_ T _._ :. _ . _ _. _� ;.� T _ ..- _ - ACD .- - NEC r ISCON T(S) SATELLITE DISH � _ C -DC FONNT—'� f /;FIRE SETBACKS.- SCEC(S) D .. .- _ - . , • _ _ _ _ �: - _ - -- � - - - : ._ - _- - . _ _ .. -- . - , Q-COMBINER BOX - --- - - -T --�- -. - -- - -- -_.. � YHARDSCAP-E _- FLINERIORQUIPMENTPROPERTY- _ .- ]f SHOWN AS DASHED Y _ sunrun LE :SCALE: NTS • _ f x - A AMPERE =--AC-- �-----�--�` ALTERNATING -CURRENT - CA CL #7501.84 r AFCI - ARC -FAULT CIRCUIT INTERRUPTER . VICINITYMAP AZIM AZIMUTH `-- _ _ - _ COMP COMPOSITION - DC DIRECTCURRENT _ _ 1zz7STRIKER AVENUE, SUITE z6o.snccrrZNro.ca 95834 PHONE 916.949.7�5 •_ - . „ - _ S _(E) EXISTING_ T - EXTERIOR IOR FRAMING FAX 916.285.9154 ( EFRM CUSTOMER RESIDENC INTERIOR BILLBASTING LBW LOAD BEARING WALL - -"MAGNETIC 11079 LONEPINE AVE C: HIC , MAG - MSP -MAIN SERVICE PANEL - CA, 95928 TEL. (530)345-912 APN -` 039-120-029=000 Nom,, .��� N NTS NO SCALE PROJECT NUMBER: •yam""" �`" ' 4 ttii>o' ' %� _ OC - ON CENTER - 105R-079BAST PRE -FAB- -PRE-FABRICATED ' PSF POUNDS PER SQUARE FOOT DESIGNER: • - PV- PHOTOVOLTAIC KYLE JENSEN `""" 3 TL TRANSFORMERLESS DRAFTER: TYP TYPICAL V SUNSOURCE VOLTS SHEET- HEET-REV W WATTS REV NAME' DATE COMMENTS COVER SHEET A Y! F REV: A 5!612016 PAGE. PV -1.0 SITE PLAN -SCALE = = PITCH TRUE MAG PV AREA SITE PLAN DETAIL - SCALE = 313�'I'-0" 3/128" 1'0" AZIM AZIM (SQFT) - AR -01 210 1870 1730 629.2 ®- - -- - ----- (E) BARN PL ----- - PL PL PL "Fns -ml CA CL # 184 750 1227 STRIKER AVENUE, SUITE 260. SAC MILENTO. CA - 95834 MAIN PANEL IS ON -A POWER_ � -- - — PHONE 9,6.949.7365 Faxs,6.zasssa ----- --- ----. . _ — _ POLE CUSTOMER RESIDENCE: - - BILL BASTING 11079 LONE PINE AVE, CHICO, _ - - CA, 95928 FIRE TEL: (530) 34-5-9124 AMI: 039-720-029-000 SETBACKS pFESs/p PROJECT NUMBER: (6-TYP) �pQ ESA X. A O Nye 10513-079BAST DESIGNER: - ._m KYLE JENSEN w o. S1672 m 9.9.7,'31951 0Y exp.06/17 ;v DRAFTER: SUNSOURCE `r�gTTigUC'Tr UFzPp���P FOFCA SHEET �F SITE PLAN Digitally Signed by James A. Adams, S.E. REV: A 5/6/2016 STAMPED FOR _ STRUCTURAL INFO ONLY PAGE PV -2.0 _ ROOF TYPE AR -01 COMP SHINGLE D1 - AR -01 - SCALE: 3/16" =1'-0" PITCH: 21' AZIM:187° ATTACHMENT L FOOT. SEE PEN D01 HEIGHT ROOF FRAME EXPOSURE MATERIAL :STORY EXPOSED WOOD _ L OC ROOF EDGE MAX RAIL MAX LAILDESIGN CRITERIA SIZE SPAN ACING ZONE SPAN 49'-7" _ T i 2'-8" TYP T j 32" T- 0" 2' - 8" 0' - 10" HANWHA Q -CELLS: Q.PRO BFR - - — - G4.1 265 FRAME TYPE FRAME MAX FRAME L OC ROOF EDGE MAX RAIL MAX LAILDESIGN CRITERIA SIZE SPAN ACING ZONE SPAN OVE G MODULES: METAL PURLIN 6 X 8 20'- 0" 32" T- 0" 2' - 8" 0' - 10" HANWHA Q -CELLS: Q.PRO BFR - - — - G4.1 265 MODULE DIMS: PROCEEDING. MAX POINT LOAD: 33.8 LBS 65.7" x 39.4" x 1.26" MODULE CLAMPS: .T _ —®- Portrait: 9.84" - 13.78" NOTE: INSTALLERS Landscape: 0" - 3.94" TO USE SCREWS MAX DISTRIBUTED LOAD: 2.82 INSTALLED IN PSF ACCORDANCE WITH SNOW LOAD: 0 PSF r—I ICC -ESR 1976. WIND SPEED: 110 MPH 3 -SEC GUST. . LAG SCREWS: 5/16"x3.5": 2.5" MIN EMBEDMENT SCREWS Fl1LLY PENETRATING _ ...__....-_ 13,__3., NOTE: - -� INSTALLERS TO VERIFY RAFTER SIZE, SPACING AND SLOPED —G}— —(D- — =r SPANS, AND NOTIFY E.O.R. OF . ._ ' CACL #750184- 1227 STRIKER AVENUE, SUITE 260. SACRA?MITO, CA PHONE 916:949.7265 FAX 916.285.9154 CUSTOMER RESIDENCE: $1LL BASTING 11079 LONE PINE AVE, CHICO, CA, 95928 TEL. (530) 345-9124 APN -: 039-120-029-000 PROJECT NUMBER: 105R-079BAST DESIGNER: KYLEJENSEN 9;9 ;es M; DRAFTER: SUNSOURCE SHEET LAYOUT REV: A 5/6/2016 PAGE PV -3.0 Digitally Signed by James A. Adams, S.E. STAMPED FOR STRUCTURAL INFO ONLY I ANY DISCREPANCIES -BEFORE ® - — - NOTE. (2) 1/4"-14 OR 1/4"-28 TEK PROCEEDING. MAX POINT LOAD: 33.8 LBS 0.©! .T . ._ ' CACL #750184- 1227 STRIKER AVENUE, SUITE 260. SACRA?MITO, CA PHONE 916:949.7265 FAX 916.285.9154 CUSTOMER RESIDENCE: $1LL BASTING 11079 LONE PINE AVE, CHICO, CA, 95928 TEL. (530) 345-9124 APN -: 039-120-029-000 PROJECT NUMBER: 105R-079BAST DESIGNER: KYLEJENSEN 9;9 ;es M; DRAFTER: SUNSOURCE SHEET LAYOUT REV: A 5/6/2016 PAGE PV -3.0 Digitally Signed by James A. Adams, S.E. STAMPED FOR STRUCTURAL INFO ONLY NOTE. (2) 1/4"-14 OR 1/4"-28 TEK 0.©! .T _ —®- T r—I . SCREWS Fl1LLY PENETRATING _ ...__....-_ 13,__3., _. _ _ _._ _ THE PURLI.N.FLANGES AT -EACH - T T T -1 -,I T —I --_ — - - Q Q� - y- — STANDOFF__ . ._ ' CACL #750184- 1227 STRIKER AVENUE, SUITE 260. SACRA?MITO, CA PHONE 916:949.7265 FAX 916.285.9154 CUSTOMER RESIDENCE: $1LL BASTING 11079 LONE PINE AVE, CHICO, CA, 95928 TEL. (530) 345-9124 APN -: 039-120-029-000 PROJECT NUMBER: 105R-079BAST DESIGNER: KYLEJENSEN 9;9 ;es M; DRAFTER: SUNSOURCE SHEET LAYOUT REV: A 5/6/2016 PAGE PV -3.0 Digitally Signed by James A. Adams, S.E. STAMPED FOR STRUCTURAL INFO ONLY • 120/240 VAC SINGLE PHASE SERVICE OMETER#: M PG&E 1007334412 UTILITY GRID EXISTING 200A/ NEW 200A ^ SPLIT BREAKERS ^ r��tTFa! sys fl GROW. • I 'r • 0 CONDUIT SCHEDULE ' HANWHA Q -CELLS Q,.PRO CONDUIT .. _ _ :CONDUCTOR- - EXISTING EXISITING .-- - - - .GROUND__ 1 ^� ABB: ^� 200A 200A MAIN UNO-7:6-TL-OUTD-S-US-A JUNCTION BOX PV MODULES (2) 10.AWG PV WIRE NONE ^� MAIN PANEL (240V) OR EQUIVALENT 1A PANEL (N) SUN RUNATT // HANWHA Q -CELLS: Q.PRO BFR - G4.1 265 2 3/4" EMT OR EQUIV. FACILITY 7600 INVERTER + 4 3 METER 3 76 _.._..W .. __._ _ .- . ! (.11) MODULES LOADS NONE (1) 10 AWG THHN/THWN-2- :Harm (1) STRING OF (11) MODULES -,3/4"- EMT-OR'EQUIV-- --(2)-8;-AWG-THHN/THWN-2--- -(1)49 AWG�THHN/TFIWN 2- -(1 ).•8 AWGwTHHN/THWN-2- _ oc PV MODULES ~ GFPD k GN HANWHA Q CELLS' Q PRO BFR G4 1 265 - _ ._ _ _ -250V - ... �// 40A PV METER_ - _ + - - - - - - -DUAL-MPPTSTRING. _..� 2B (2-STRDUCES - --- --SOCKET.. - - 4 __ _ - -- BREAKER AT --- -. - - - - COMBINER & LOAD 1. (2) OF (12) MODULES_ OPPOSITE END 125A CONTINUOUS _T RA ED DC DISCONNECT " 240V METER" r - 200A, FORM 2S r CONDUIT SCHEDULE ' HANWHA Q -CELLS Q,.PRO CONDUIT .. _ _ :CONDUCTOR- - ___ _.:. - _NEUTRAL. - - .-- - - - .GROUND__ 1 NONE (2) 10.AWG PV WIRE NONE (1) 10 AWG BARE COPPER . 2 3/4" EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 - NONE (1) 10 AWG THHN/THWN-2- -3-- -,3/4"- EMT-OR'EQUIV-- --(2)-8;-AWG-THHN/THWN-2--- -(1)49 AWG�THHN/TFIWN 2- -(1 ).•8 AWGwTHHN/THWN-2- _ EXISTING: -WIRING_ - ELECTRICAL PANEL 1S MOUNTED ON POWER POLE MODULE CHARACTERISTICS HANWHA Q -CELLS Q,.PRO 9275W BFR - G4.1 265 265 W OPEN CIRCUIT VOLTAGE 37.93 V MAX POWER'VOLTAGE 31.03 V' SHORT CIRCUIT CURRENT 9.15 A SYSTEM CHARACTERISTICS - INVERTER 1 SYSTEM SIZE ' - 9275W SYSTEM OPEN CIRCUIT VOLTAGE 493 V SYSTEM OPERATING VOLTAGE 372 V MAX ALLOWABLE DC VOLTAGE 600 V SYSTEM OPERATING CURRENT 25.62 A SYSTEM SHORT CIRCUIT CURRENT 34.31 A PER CODE: 690.52 NOTES TO INSTALLER: - - - 1. 455VDC EXPECTED OPEN CIRCUIT STRING VOLTAG_E -2ADD4QAMPPV,BREAKER:TO_EXISTINGUPAN. 3. PANEL MANUFACTURER: SIEMENS; REQUIRED BREAKER: Q-260. - sunrun CA. CL #750184 - - - 1277 STRIKER AVENUE, SURE 260, SAORM04TO. CA 95334 _ PHONE 916.949.7365 FAX 916.285.9154 CUSTOMER RESIDENCE: _ BILL- BASTING - 11079 LONE PINE -AVE, CHICO, CA, 95928 - - TEL (530) 345-9124 APN E.-039-120-029-000 PROJECT NUMBER: 105R-0.79BAST DESIGNER: KYLE JENSEN DRAFTER: SUNSOURCE SHEET ELECTRICAL REV: A 5/6/2016 PAGE PV -4.0 ®WARNING ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED LABEL LOCATION: DC DISCONNECT, INVERTER (PER CODE: CEC 690:35(F)) [To be used when inverter is ungrounded] A WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN -THE OPEN POSITION DC VOLTAGE IS ALWAYS PRESENT -- --WHEN SOLAR MODULES ARE_-- - EXPOSED TO SUNLIGHT LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC690.54) LABEL -LOCATION: _ - POINT OF INTERCONNECTION (PER CODE. CEC 705.12(D)(7)) [Not required if panelboard is rated not less than sum of ampere ratings of all overcurrent devices supplying it] i r L LABEL LOCATION: -.. _.. _ I`iARKI 1VGS PLACED ONLABEL LocanoN: ALL INTERIOR AND EXTERIOR DC £O'J T W '.T-~--- - -. AC`DISCONNECT, POINT OF INTERCONNECTION. -AND CABLE.ASSEMBLIES:ALLEASTE!ERY:10_FT,AT;TURNSANDABOVEIBELOW.PENETRA710tS,. (PER CODE: CE690.53) ADHESIVE FASTENED SIGNS: • THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. • WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS. AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [NEC 110.21(B) FIELD MARKING[. • ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED- VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.31 J i - -- • -(P.ER CODE_ CEC 690:17 E - •__..... _____ _ _ ( )) _ _ AND ALL COMBINER/J1. UCTION BOXES PER CODE: IFC6051.11.1.4)- . _.. ( - - - - - - - - - - - - - - _ 1tlARNIN-= -- - ELECTRIC SHOCK HAZARD - LABEL LOCATION: _ LL - DO NOTTOUCH TERMINALS DISCONNECT, POINT OF INTERCONNECTION�'- �' _ '. — - _ TERMINALS ON BOTH LINE AND._. (PER CODE: CEC690.13(8))-- - LOAD SIDES MAY BE ENERGIZED -WARNING 1N THE OPEN POSITION. -' DUAL POWER SOURCE- OURCE - - - LABEL LOCATION: LABEL SECOND SOURCE IS PHOTOVOLTAIC SYSTEM -•1- - _ - -AC DISCONNECT, POINT OFINTERCONNECTION'- N ­ PER PER CODE: CEC 690.17(E); CB LOCATION: sunrun. POINT OF INTERCONNECTION� - - (PER CODE_ CEC 705.12(D)(4)) _ CAUTION: SOLAR ELECTRIC - CA CL #750184 — - ' -:LABEL LOCATION: _ . _ — . _ . , _ _ LABEL -LOCATION: - INVERTER, JUNCTION BOXES (ROOF), AC DISCONNECT WEATHER RESISTANT. MATERIAL, DURABLE ADHESIVE,^ (PER CODE: CE0690.13.0:3 8 CEC 690.13.0.4) UL969 AS STANDARD TO WEATHER RATING (UL LISTING - '- " _ ' ' - - _ - _�-" - = 1227 STRIKER AVENUE, SUITE 260. SACRAMENTO. CA OF MARKINGS NOT. REQUIRED), MIN %- LETTER -HEIGHT T ARIAL OR SIMILAR.FONT NON -BOLD PLACED WITHIN - - PHME 916:949.76ss FAX 916.285.9154 - -. - ..- • • ® - THE WWN SERVICE DISCONNECT, PLACED ON THE_ --�- — — i -- - E LABEL LOCATION'.. OUTSIDE OF THE COVER WHEN DISCONNECT IS I' -OPERABLE WITH SERVICE PANEL CLOSED. - - • - - - - -- - _ -- -' ' "•- _ CUSTOMER RESIDENCE - CONDUIT, COMBINER BOX = _ ,... _.._, _ _.. ,. _ .- _ � ..M. - (PER CODE: CEC690.15; sson3(ep . .y�,,,�,' _ _ BILL BASTING } (PER CODE: CEC690.31(G)(3)(4) & CEC 690.13(G)(4) 11079 LONE PINE AVE, CHICO, . INVERTER 1 - r _ .CA 95926 (PER CODE: CE690.53) ADHESIVE FASTENED SIGNS: • THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. • WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS. AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [NEC 110.21(B) FIELD MARKING[. • ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED- VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.31 J i i . I,