HomeMy WebLinkAboutB16-1080 042-770-016ANTI -ENTRAPMENT CERTIFICATION FORM FOR SWIMMING POOLS & SPAS 816 -)o,�>6 FORM NO The following form is required whenever a building permit is issued to construct or repair (re plastering) a swimming pool, toddler pool, or spa. STATEMENT TO BE SIGNED PRIOR TO FINAL APPROVAL Verification of Compliance with the "Swimming Pool Safety Act of 2006" (Health & Safety Code 115920 —115929) Site Address: Property Owner: Phone: Owner's Mailing Address: hereby certify that the swimming pool, toddler pool, or spa located a the above- mentioned address complies with the provisions or the "Swimming Pool Safety Act of 2006" and has been equipped with an anti -entrapment cover meeting the current ASME/ANSI Standard A 112.19.8 as required under the provisions of the law and have received additional information on pool barrier requirements. Signed: Date: Owner Signed: Contractor Date: CONTRACTOR'S INFORMATION Company Name: California Contractor's License Number: I Mailing Address: Phone: Email: Attachments: Swimming Pool Enclosure Requirements and Pool Barrier handout 7 -fin )nl Pagel of3 li10TIV Swimming Pool Enclosure Requirements Definitions Approved Safety Pool Cover: A manual or power -operated safety pool cover that meets all of the performance standards of the American Society for Testing and Materials (ASTM), in compliance with standard F 1346-91. Enclosure: A fence, wall or combination thereof that isolates a swimming pool from unauthorized access. Exit Alarm: A device that makes an audible, continuous alarm sound on the doors leading from the dwelling/garage or other structure to the pool enclosure, which, when opened or left ajar, permits entry to the pool without any intervening enclosure device. Exit alarms may be battery operated or connected to the electrical wiring of the building. Public Swimming Pool: A swimming pool operated for the use of the general public with or without charge, or for the use of the members and guests of a private club. Public swimming pool does not include a swimming pool located on the grounds of a private single family dwelling. Swimming Pool or Pool: Any structure intended for swimming, recreational bathing or other recreational use that will contain water over 18 inches in depth. Swimming pools include in -ground and above -ground structures and include, but are not limited to, hot tubs, spas, portable spas and non-portable wading pools. Other terms, words, or phrases not defined shall have their ordinarily accepted meanings within the context with which they are used. Webster's Third New International Dictionary of the English Language, Unabridged, copyright 1986, shall be considered as providing ordinarily accepted meanings. pvii zp ')n ')n i N Page 2 of Swimming Pool Requirements Drowning Prevention Safety Features Based upon California Health and Safety Code Section 115920-115929, known as the Swimming Pool Safety Act The County of Butte requires either a listed, approved safety pool cover* meeting ASTM Standard F1346-91, OR a complying enclosure* which isolates the pool from the dwelling and remaining yard, OR a complying enclosure* which surrounds the perimeter of the pool and dwelling, with door alarms and self-closing, self latching devices on all doors leading into the enclosure. *Enclosures • Minimum height of 60 inches • Access gates shall open away from pool and have self-closing, self -latching device no lower than 60 inches above the ground. • Maximum vertical clearance of 2 inches from the ground to the bottom of enclosure • No openings greater than 1/2 inch within 18 inches of the release mechanism when closed. Gaps or voids shall not allow the passage of a 4 inch sphere. • Outside surface shall be free of cavities or protrusions that would serve as a foothold or handhold that could enable a child of less than 5 years of age to climb over. • Maximum mesh size for chain link shall be a 2.25 inch square unless the fence is provided with slats fastened at the top or bottom which reduce the openings to no more than 1.75 inches *Pool Cover • Shall be correctly installed per the manufacturer's instructions to prevent the access of children under five years of age to the water. • Shall be properly constructed to meet ASTM specifications and be labeled accordingly. • All ties, anchors or attachment points and controls for automatic covers must be installed in a way to prevent operating or uncovering the poll by children less than five years of age. • The pool cover shall possess a listing that insures the original design or performance of the cover meets. or exceeds testing as prescribed by ASTM Standard F1345-91, Section 9 Test Methods for Safety Covers. Door alarms or self cloOng, self -latching doors Windows and doors�r routinely closed and s latches LEI"Safety pool j cover ✓r Perimeter fenc At a w4pirtim, one d tlm-se shop be prov40d Rp.vi�Pri 7.20,2015 Page 3 of serf -doting, self -latching (REMed 4108). WATER SUPPLY AND DISTRIBUTION TABLE 603.2 i BACKFLOW PREVENTION DEVICES, ASSEMBLIES, AND METHODS DEGREE OF HAZARD POLLUTION DEVICE, ASSEMBLY APPLICABLE (LOW HAZARD) ? CONTAMINATION (HIGH HAZARD) DEVICE, ASSEMBLY, , OR METHOD' STANDARDS BACK• I BACK• I BACK- BACK- I INSTALLATION2,3 , SIPHONAGE PRESSURE SIPHONAGE PRESSURE ASME Air gap -. A 112 12 X — ( X — See Table 603.3.1 in this chapter. — ,age machines or dispensers. These 'Air a fitting is a device with an Inter- { gap Air gap fittings for use ASME 'with plumbing fixtures, ' ! A 112 1 3 X i X S 'nal air gap and typical installation i ances and appurte- I — — includes plumbing fixtures, appliances nan' Idownstream. Minimum of 12 inches ff and appurtenances. The critical level shall' X — X above all downstream piping and i loaded check valve X be installed below the flood level rim. !Atmo.appspheric vacuum (Vacuum Breaker (single charge water. Resting) .... _ ___ -- Upright position. No valve down - breaker (consists of a body, ASSE 1001 or X !check valve with air inlet field I X stream. Minimum of 6 orches or listed :checking member and , CSA B64.1.1 I _ vent and means of — (two independently distance above all downstream piping ,atmospheric port) { piping and flood -level rim of receptors Resting) _ _. ... I i and flood -level rim of receptor.°• ;Antisiphon fill valve (ball- ;cocks) for water ASSE 1002 I j I means of field testing) Installation on gravity water closet flush tank and urinal tanks with the fill gravity :closet or X _ X — Access and clearance shall be in actor- valve installed with the critical level not flush tanks and uri- :nal tanks I CSA B 125.3 Not to be subjected to operating pressure for more than 12 hours in a 24 hour period. s For deck -mounted and equipment -mounted vacuum breaker, we Section 603.5.14. dance with the manufacturer's inatruc- i ;CSA 864.5 or less than I inch above the opening of '..__. .__...- — I tions, end not less than a 12 inch clear - ' and means of field (testing) CSA 864.5.1 the overflowpipe.4•s breaker wall ante at bottom for maintenance. May ' Installation Includes wall hydrants and ,Vacuum .hydrants, hose bibbs, frost ASSE 1019 or hose bibbs. Such devices are not for use resistant, automatic drain- ;CSA 864.2.1.1 X — X — ----- ,under continuous pressure conditions ing type ._ _e Check Detector - '(means ofshutoff downstream of device is prohibited).'-' 'Backflow for i I BACKFLOW PREVENTION DEVICES, ASSEMBLIES, AND METHODS (continued) d Beverage Beverage DEGREE OF HAZARD DEVICE, ASSEMBLY, , APPLICABLE POLLUTION CONTAMINATION LOW HAZARD ( ) (HIGH HAZARD) Installation includes carbonated bever- i ICarbonated eatDis pensers (two independent ASSE 1022 X — — — ,age machines or dispensers. These ;check valves with a vent to Breaker Backflow I differential pressure devices operate under intermittent or ;the atmosphere) i Upright position. May have valves (loaded air inlet I Idownstream. Minimum of 12 inches continuous pressure conditions [Spill Resistant Pressure X — X above all downstream piping and i loaded check valve X flood -level rim of receptor. May dis- I I ! and means of field (Vacuum Breaker (single charge water. Resting) .... _ ___ -- ---- --- I (Upright position. Minimum of 12 inches !check valve with air inlet field ASSE 1056 I X — X— r Horizontal unless otherwise fisted. or listed distance above all downstream vent and means of ( Access and clearance shall be in actor. (two independently AWWA C51 I; dance with the manufacturers instmc- piping and flood -level rim of receptors Resting) _ _. ... I __. pressure relief valve I —.... ._..._._. _.._.. _.._.. — `i I I i I ( repair. May discharge water. means of field testing) Horizontal unless otherwise fisted. :Double Check Valve Back_ ASSE 101 S, i I For SI units I inch - 25.4 mm `-- -- Access and clearance shall be in actor- ,(ow Prevention Assembly AW WA CS 10; 3 Refer to general and specific requirement for installation. Not to be subjected to operating pressure for more than 12 hours in a 24 hour period. s For deck -mounted and equipment -mounted vacuum breaker, we Section 603.5.14. dance with the manufacturer's inatruc- two Inde ndent check valves ;CSA 864.5 or X X T — I tions, end not less than a 12 inch clear - ' and means of field (testing) CSA 864.5.1 ante at bottom for maintenance. May need platform ladder for test and repair. Does not discharge water. ---- ----- —rHorizontal Check Detector unless otherwise listed. (Double Fire Protection Backflow I Access and clearance shall be in actor - !Prevention Assembly (two ( dance with the manufacturer's instmc- 'independent check valves I I tions, and not less than a 12 inch clear - with a parallel detector ASSE 1048 X X — — ance at bottom for maintenance. May Y consisting of a I need platfann/ladder for test and repair. (assembly water meter and a double I Does not discharge water. Installation :check valve backflow pre- I I includes a fire protection system and is vention assembly and designed to operate under continuous _means of field testing) ! pressure conditions. 130 2013 CALIFORNIA PLUMBING CODE WATER SUPPLY AND DISTRIBUTION .a,s•n TABLE 603.2 BACKFLOW PREVENTION DEVICES, ASSEMBLIES, AND METHODS (continued) Horizontal unless otherwise listed. DEGREE OF HAZARD DEVICE, ASSEMBLY, , APPLICABLE POLLUTION CONTAMINATION LOW HAZARD ( ) (HIGH HAZARD) OR METHOD' I STANDARDS BACK -_BACK-- BACK- 'BACK. INSTALLATION2,3 Ioadedcheek valves, a I. SIPHONAGE PRESSURE SIPHONAGE PRESSURE _ _.. _ I Pressure Vacuum Breaker Backflow I differential pressure Prevention Assembly i Upright position. May have valves (loaded air inlet ASSE 1020 or Idownstream. Minimum of 12 inches valve, internally CSA 664, t.2 X — X above all downstream piping and i loaded check valve X flood -level rim of receptor. May dis- I I ! and means of field charge water. Resting) .... _ ___ -- ---- --- I .. - _._.... ..._. lReducedPressure assembly consisting of _._..... .—� i I Principle Backflow r Horizontal unless otherwise fisted. . Prevention Assembly ASSE 1013; ( Access and clearance shall be in actor. (two independently AWWA C51 I; dance with the manufacturers instmc- acting loaded check valves, a differential CSA B64.4 or X X I X X tions, and not less than a 12 inch clear.:! I pressure relief valve CSA 1364.4.1 ( ante at bottom for maintenance. May I Y need platforrilgadder for test and and means of field I I i I ( repair. May discharge water. Reduced Pressure Detector Fire Protec- tion Backflow Preven- tion Assembly (two Horizontal unless otherwise listed. independently acting Access and clearance shall be in actor Ioadedcheek valves, a dance with the manufacturer's instruc- I differential pressure : ' tions, and not less than a 12 inch clear- relfe v I relief v, with a ASSE 1047 X X X X ante at bottom for maintenance. May y parallel detector I need platformlladder for test and assembly consisting of repair. May discharge water. Instal Is - a water meter and a reduced -pressure prin- i ciple backflow pre- I tion includes a fire protection system and is designed to operate under con- sinuous pressure conditions. ;;vention assembly and means of field testing) —�-- ----'--- For SI units I inch - 25.4 mm `-- -- Notes; i See description of devices and assemblies in this chapter. = Installation in pit or vault requires previous approval by the Authority Having Jurisdiction. 3 Refer to general and specific requirement for installation. Not to be subjected to operating pressure for more than 12 hours in a 24 hour period. s For deck -mounted and equipment -mounted vacuum breaker, we Section 603.5.14. f--1r_r�-_-- I 11 CT' 60.4, port - o� SG Z1 j 7Z'g Cts.\\a i,,,..ve- PERMIT BUTTE GtOUN TY DEVELOPMENT SERVICES /-36 REVI WED FOR COMPLIANCE DATE—� . �Y------- i f c? I t I E,c�sf� ci � M r TSC�'IG /'7i1Na ( JO//'�r �PQG�I I N In CALCULA TIONS y = EQUIVALENT FLUID PRESSURE RESISTING MOMENT ABOUT POINT A RM = Wt d, + W2d2+ ... W"d" CASE I OTM = 1/6 y H3 WHERE y = 60 pcf W di W 1 d NET MOM = OTM - RESISTING MOMENT W2 2 I's pI's W P.S.I. 3'-6" OCHE II 1/6 y H3 WHERE y = 62.4 pcf W3 d3 -53 2 W, � d d3 W" = wt. NET MOM = OTM +RESISTING MOMENT W. I d4 10.6 W I.it 640 of segment„ fs = M(12 in/ft) = Mt (12) W5 d a 3" 4 WS #3 0 6" As j d As (0.887) d 12 in/ft d6 w6 1 A W6 ItA d6 M(2) 230 -57 3�/Z" fc = jkbd2 6'-0" 17454 Mt (2)(12) CASE CASE II - < 1125 psi - (0.887)(0.339)(12) d2 LOADING DIAGRAM: 497 (1/2) y H2 vc THIS DETAIL IS DESIGNED FOR = (12 in/ft) j d EACH OF THE LOAD CASES DEFINED BELOW. _ y H2 (2)(12)(0.887) d < 55 psi 580 22.5 f'c = 2,500 psi 3430 3567 Fs = 20,000 psi 315 3882 fc = 0.45 f'c = 1125 psi 5'/Z" 508 Vc=1.1I'fc =55 psi 832 30.6 8'-0" y = 60 P.C.F. y = 62.4 P.C.F. 2259 CASE I CASE II CALCULATION RESULTS: FREESTANDING WALL EXPANSIVE SOIL EQUIVALENT FLUID PRESSURE = 60 P.C.F. RESULTS FOR NO RAISED BOND BEAM DEPTH SOIL OTM ft-# WATER OTM ft-# SOIL RM ft-# WATER RM ft -1 NET Mom CASE I d1 SOIL CASE II d2 WATER VERTICAL STEEL I's pI's fc pfc P.S.I. 3'-6" 429 446 106 -53 393 3" 3" #3 ®12" 15354 427 10.6 4'-0" 640 666 124 -55 611 3" 3" #3 0 6" 12275 508 13.9 5'-0" 1250 1300 230 -57 1020 3�/Z" 4%" 6'-0" 17454 660 17.9 6'-0" 2160 2246 497 -2 1663 4" 5%* add 3 #4 8283 580 22.5 7'-0" 3430 3567 1046 315 3882 4" 5'/Z" 508 13807 832 30.6 8'-0" 5120 5325 2259 971 6296 4" 61h -T188671 195 781 998 40.0 8'-6" 6141 6387 4820 888 7275 4" 7%Z" 7918 8" 889 45.2 RESULTS FOR 2"-6- MAX. KAIJtU UUNU Or -MM HEIGHT 'H' SOIL WATER OTM OTM ft-# ft-# SOIL RM ft-# WATER RM ft -1 Mom CASE I d1 SOIL CASE II d2 WATER VERTICAL STEEL I's p.s.i. fc p.s.i. tic P.S.I. 3'-6" .429 10 106 _[�NET -53 323 3" 3" #3 ®12" 12607 351 10.2 4'-0" 640 35 116 -63 524 3" 3" #3 0 6" 10537 436 13.3 5'-0" 1250 163 135 -99 1115 3�/Z" 3" 5%" 19071 722 17.9 6'-0" 2160 446 163 -165 1997 4�%t" 3" #3 3" 13563 666 20.0 T-0" 3430 948 251 -163 3179 5" 3" i-jo- 19325 891 24.5 8'-0" 5120 1730 508 -82 4612 6" 3" add 3 #4 14965 938 26.7 9'-0" 7290 2856 1031 195 6259 61%" 4" 3'-2" 18669 1064 31.2 10'-0" 10000 4388 2082 611 7918 8" 5%" 18993 1021 31.3 1 l'-O"l 13310 1 6387 6678 291 1 6678 1 8'{h" W 19921 1034 35.6 a HORIZONTAL STEEL 13 BARS 0 12" O.C. TYP. THROUGHOUT. VERTICAL STEEL n SEE TABLE 551. OPTIONAL d2 FILL 7 BEGINNING 0 D = 5'-0" USE 13 BARS 0 12" O.C. BEGINNING 0 D = 6'-0" OR MORE USE #4 BARS 0 12" O.C. COPING. BOND BEAM PER STANDARD /-POOL STRUCTURAL PLAN, DETAIL #1 do #12 W/ (4) 14 BARS. TOP OF BOND BEAM (STANDARD WALL) J —WATER UNE. a 3 io C=7 RADIUS M °1 POINT. CL o 1-10 0 SLOPING CONDITION a REQUIRES APPROVAL / I _.�3:3 �I OF SOILS ENGINEER. / (UNDISTURBED SOIL) / SQUARE -OFF WHEN NATURAL GRADE OR ENGINEERED COMPACT FILL IS BELOW RADIUS POINT. VERTICAL STEEL- SEE TEELSEE TABLE 551. i i i i TABLE 551 'D' OR 'H' IS DISTANCE FROM TOP OF POOL WALL DOWNWARD. BEGIN SPECIFIED STEEL & GUNITE THICKNESS AT INDICATED 'D' OR 'H' DEPTH. (SEE STANDARD STRUCTURAL PLAN, DETAIL 12) POOL DEPTH NO RAISED BOND BEAM REQ'D D d1 d2 VE STEEL TRANS. 0 to 3'6" 3" 3" #3 0 12" 2'-0" 4'-0" 3" 3" #3 0 6" 2'-0" 4'-6" 3" 3%" 3'/Z" 2'-0" 5'-0" 3%" 4%" » 2'-0" 5'-6" 4" 5i%» » 2--0- ,-0»6'-0" 6 . -0" 4" 5%" add 3 #4 2'-0" 6'-6" 4" 5%" 5" 2'-0" 7'-0" 4" 5%" " 2'-0" 7'-6" 4" 5%" 6" 2'-0" add 3 #4 2'-10" 8'-6" 6" 3%" E8'-6" 4" 7�%' 6% i-jo- TOTAL HEIGHT 2'-6" MAX. RAISED BOND BEAM REQ'D TRANS' H d 1 d 2 VERTICAL STEEL 0 to 3'6" 3" 3" #3 0 12" 2'-0- 14'-0' 3" 3" #3 0 6" 2'-0- ,4'-6- 3" 3" mZ15 2'-0" 5'-0" . 3'/Z" 3" " 2,-0» 15'-6" 41h" 3" 2'-0" 6'-0• 4+%" 3" #3 0 3" 2'-0- 6'-6- 4W 3" 2'-0» 7'-0" 5" 3" " 2'-8» 7'-6" 6" 3" 2'-8" 8'-0" 6" 3" add 3 #4 2'-10" 8'-6" 6" 3%" 2'-11" 9'-0" 6% 4" " 3,-0» 9'-6" 7" 5" 3'-2" 10'-0" 8" 5%" " 3'-2" 10'-6" 836" 6%» » 3'-2- 11--o' 1 8%Z" 6�ii" 3'-2" Qom' HORIZONTAL STEEL 13 BARS 0 12" O.C. TYP. THROUGHOUT. TOP OF BOND BEAM (WALL W/ R.B.B.) cv SES TABLE 551 TRANSITION WALL TO FLOOR STEEL do THICKNESS Idl do d2 TO BE CHANGED UNIFORMLY. SEE TABLE 551. TYPICAL REBAR REINFORCING DIAGRAM TOP OF POOL WALL BASIC GRID #3 BARS 0 12" O.C. EACH WAY. VERTICAL REINFORC_MENT AS SPECIFIED IN TABLE STARTS A DISTANCE V OR 'H' DOWN FROM TOP OF POOL WALL. REINFORCEMENT OTHER THAN BASIC GRID NEED NOT EXTEND TO TOP OF POOL WALL ADD BARS TO BE EQUALLY SPACED BETWEEN BASIC GRID. 13 r r o NO rn 0 1 _ uj �j Q o co M o co i N c UF- Ev T mZ15 ci b L C c 0 co co 0- �°CNQu- 613012017 CIVIC Ej Of CAS\�0 zz 0 V)LLJ U Z J Z a- 0 Z 0 V U w z� �Z oN 3 Lj N W = 0 J LJ z 0 z m o M Ld o J Q Q zZ �iN DATE: 12/20/10 v—, CALCS BY: A.C. CHECKED BY: R.L.L. FREESTANDING WALL EXPANSIVE SOIL EQUIVALENT FLUID PRESSURE = 60 P.C.F. DETAIL #551 SII BENCH AND STEP OPTIONS: SLOPE EARTH SURFACE 1/4' PER NOTE: TABLE NO. 1 GENERAL NOTES GLAZING IN HAZARDOUS LOCATIONS BOND BEAM HORIZONTAL BARS MAY BE 1. UNDISTURBED EARTH MAY BE LEFT IN PLACE TO FORM THE STEPS OR BENCHES. REINFORCING STEEL FOOT OR SLOPE DECKING 1/8" TO OVER OR UNDER VERTICAL BARS. SHOULD BE PLACED AROUND THE STEP OR BENCH SHAPED EARTH (3" CLEAR FROM EARTH). 1/4" PER FOOT AWAY FROM POOL TYPICAL INCLUDING ALL SPECIAL DETAIL 2. THE EARTH MAY BE REMOVED AND BENCHES AND STEPS MAY BE FORMED OF SHOTCRETE (GUNITE) WITHIN 2 STORY WOOD THE STRUCTURAL POOL SHELL REINFORCING AT THE SURFACE OF THE BENCHES AND STEPS IS OPTIONAL. APPROVED SEALANT RECOMMENDED (PER FRAME BUILDING DETAIL #8). REQUIRED W/ EXPANSIVE SOIL TABLE 1 TABLE 5 BASIC GRID #3 1500 #/FOOT MAX. r•� BARS 0 12" O.C. COPING BRAIN BOND BEAM A TABLE TABLE TABLE WATER SURFACE. �- - SEE TABLE #1 & DETAIL #12. DECKING. MINIMUM11 ol WIDTH PER LOCAL BOND B. 3" BELOW B E F G BOND BEAM. BUILDING CODE. W % 4 " M (✓ 3'-0" MIN. z "ii' z 3 m o m rn COPING M g CL w Z 3. ¢ F NO R.B.B. € o- o o rn ori I .. _ .. ¢ 1s m �; r _. s Z CLR. rn x o I --. _._ �. _ ..-..__ - - - ¢ ¢m - N o o BENCH/STEPS - I.� Of i- ¢ EE OPTION 1 a ¢ 0 0 o S S �� 1 1/ UNDISTURBED SOIL fO o r n € c� ABOVE F 1500 PSF MIN. � 1 ¢ J BEARING VALUE. .. - --- ---- N j .. I r INFLUENCE LINE i � 1 UNDER- -- �. FOR FOOTING 'C' SHOTCRETE COVER .�... ......._. TO BE CHANGED WATER I I SURCHARGE € LIGHT PER I I I SEE UNIFORMLY. 1 DETAIL #10. ......_......;_. _......I.....€..._...:.. ......„.. " ADD 3 0 12" O.C. I 5 �0 # l LONGITUDINAL 0 TRANSITION ACTUAL DIG LINE MAY�jI ,I • FOR EXP. SOILS. VARY, (LOCATE STEEL . . • • -.--i.l . •-r-i.i... r' 3" CLR FROM EARTH ; STEEL BASKET IS NOT REQUIRED �I1 3 TYI'• FLOOR SURCHARGE CONDITION: - - - -11 16 '` 6" THICK MIN. SHOTCRETE (GUNITE) USE TABLE 1 SCHEDULE 'D', VERTICAL EE T BLE STEEL. 24' MIN. H DRAIN PIPE SHALL NOT W/ #3 BARS 0 12" O.C. (BUILDING SURCHARGE) WHEN EXTEND WALL ENCROACH INTO GUNITE SHELL EACH DIRECTION SETBACK TO BUILDING FOUNDATION HORIZONTAL STEEL ro REINF. INTO FLOOR. CIRCULATION DRAINS: IN HIGH WATER TABLE, INSTALL 'W IS LESS THAN POOL DEPTH. #3 BARS 0 12" O.C. (30' MIN. FOR TABLE 5G) PROVIDE (2) ANTI -VORTEX SUCTION OUTLETS PER PUMP, HYDROSTATIC VALVE AND ROCK COVERED WITH APPROVED A.S.M.E. STANDARD A112.19.8 PACK AT LOW POINT. (6' HIGH MAX. FREESTANDING ADDITIONAL BARS BEGIN AT 5'-0" FROM THE TOP OF THE POOL ANTI -ENTRAPMENT GRATES THAT ARE HYDRAULICALLY MASONRY SCREEN OR GARDEN WALL RAISED OR OT RATS S. DI NON -EXPANSIVE EXPANSIVE NO DECK/HIGH EXP. BUILD'G SURCHARGE A B C D (3) #3 BARS (4) #3 BARS (4) #3 BARS. OWNER TO NOTIFY POOL ENGINEERING INC. AND OBTAIN APPLICABLE SPECIAL CONTINUOUS SHOTCRETE INSPECTION E.F.P. 30 P.C.F. 45 P.C.F. 65 P.C.F. 45 P.C.F.' D R C VERTICALC STEEL 7, POOL/SPA WATER HEATER AND GAS PIPING INSTALLATION TO BE IN CONFORMANCE PATH THE CPC. VERTICAL STEEL C VERTICAL STEEL C VERTICAL STEEL 3'0" 1'-0" 3" #3 0 12" 3" #3 0 12" 3" #3 0 12" 3" #3 0 12" 3'6" 1'-0" 3" 6. ALL CONSTRUCTION MALL COMPLY WITH THE 2013 EDITIONS OF THE CALIFORNIA ELECTRIC RESISTANCE HEATING AND NO PILOT LIGHT. 6'0" 3%" 3'3" - - CODE (CMC), CALIFORNIA PLUMBING CODE (CPC), CAUFORNIA ENERGY CODE, 2013 A) AT LEAST 36" PIPE BETWEEN FILTER & HEATER FOR FUTURE SOLAR HEATING. .... BUILDING ENERGY EFFICIENCY STANDARDS, 2013 CALIFORNIA GREEN BUILDING B) COVER FOR OUTDOOR POOLS OR OUTDOOR SPA. 3' 4'0" V-0" 3' 7. POOLS WITH DIVING BOARDS SHALL MEET DIVING BOARD MANUFACTURER'S POOL PERMIT OFF PEAK OPERATION. 6" 3' 7'0" 5" SIGNS & SAFETY EQUIPMENT SHALLLCAL BE INSTALLED IN ACCORDANCE WITH LOCAL CODES. BARRIERS 4- 9. PUBLIC POOLS REQUIRE COUNTY HEALTH DEPARTMENT APPROVAL AND PROVISIONS FOR 1. PRIOR TO FILUNG, THE POOL AND OR SPA SHALL BE COMPLETELY ENCLOSED BY 5' MIN. ASSISTIVE DEVICES FOR THE DISABLED. 4- 4'6- 1'-0" 3" SITE. POOLLENGTH, GRADE BREAK LOCATIONS &DEPTH DIMENSIONS AS NOTED ON THE SELF-CLOSING & SELF -LATCHING WITH LATCH A MIN. 5' HIGH. ACCESS GATES TOE OF SLOPE OR OTHER SURCHARGE CONDITIONS (SEE GENERAL NOTES #3) PLOT PLANT! SHALL COMPLY WITH APSP SUGGESTED MINIMUM STANDARDS FOR THROUGH FENCING SHALL OPEN AWAY FROM THE POOL. MAXIMUM VERTICAL CLEARANCE PROVIDE ADEQUATE DRAINAGE BOND BEAM PER BEHIND POOL WALL. RESIDENTIAL POOLS APPLICABLE STATE AND LOCAL HEALTH DEPARTMENTS FROM GROUND TO POOL FENCING SHALL NOT EXCEED 2 INCHES. WHERE THIS VARIES FROM STRUCTURAL NOTES i. SOIL SHALL HAVE A MINIMUM BEARING VALUE OF 1500 PSF CONCRETE SHALL BE A LOCAL CODES, THE LOCAL CODES SHALL PREVAIL REGULATIO@IS AND MANUFACTURERS RECOMMENDATIONS. 8%- 5'0" V-6" 3" #3 0 6" 4" #3 0 6" 5" #3 0 6" ....... - 5" #3 0 6- ..... ......... __ ................ 5'6' 2'-0' 3" 101 3. OBTAIN ELECTRICAL AND PLUMBING PERMITS ALONG WITH POOL BUILDING PERMIT. LESS THAN THE DEPTH OF THE POOL ADJACENT TO THE BUILDING. REFER TO STANDARD 4' 5' 5%- 6-0- 2'-6" 3" .... 10'0" 9" 4" T 11 6" 5%' 6'6" 3'-0' 3' .... .......... 4%' 7" 6%" 7'0" S-6" 3" 5" ... 8" 7%" 7'6" 4'-0' 3' - 536- 9" 8Z" - 8'6' 5'-0" 3" 6" INDICATES TYPICAL RADIUS (ACTUAL RADIUS NO DECK OR HIGH MAY VARY, SEE STRUCTURAL NOTE #11) EXPANSIVE SOIL b' i I. THIS STANDARD POOL STRUCTURAL PLAN MUST BE ACCOMPANIED BY A CLEAR PLOT MENREQUIRED E UIRED BY THE BUILDING CIA Q OFFICIAL, GLAZING SHALL COMPLY WITH THE CBC SECTION PLAN SHOWING POOL & OR SPA SHAPE, DEPTH AND DISTANCE TO PROPERTY LINE, 2406.4, INCLUDING LOCALLY ADOPTED AMENDMENTS. EXPANSIVE SLOPES AND STRUCTURES. 1. GLAZING IN WALLS AND FENCES USED AS A BARRIER SHALL BE SAFETY GLAZING WHEN (C N ED). * IF POOL WALL HEIGHT DOES NOT EXCEED 5'-0" THEN NO ADDITIONAL 2. REPRESENTATIVES OF POOL ENGINEERING INC. HAVE NOT INSPECTED THE SITE & ARE ALL OF THE FOLLOWING CONDITIONS ARE PRESENT: 4. ALL EQUIPMENT SHALL BE LISTED AND INSTALLED PER MANUFACTURERS RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL REGULATIONS. RELYING ON INFORMATION PROVIDED BY THE CONTRACTOR OR OWNER TO DETERMINE A. THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60' ABOVE ANY STANDING OR THE ADEQUACY OF THIS STANDARD POOL STRUCTURAL PLAN FOR THE ACTUAL SITE 65 P.C.F. WALKING SURFACE. CONDITIONS. SHOULD SITE CONDITIONS VARY FROM THAT COVERED BY THIS STANDARD B. THE GLAZING IS WITHIN 5 FEET OF A SWIMMING POOL OR SPA DECK AREA. VERTICALC STEEL POOL STRUCTURAL PLAN, IT IS THE RESPONSIBILITY OF THE CONTRACTOR OR THE BARS ARE REQUIRED. (DOES NOT APPLY TO SUPPLEMENT DETAILS) OWNER TO NOTIFY POOL ENGINEERING INC. AND OBTAIN APPLICABLE SPECIAL CONTINUOUS SHOTCRETE INSPECTION 5. POOLS SHALL BE EQUIPPED WITH A FILTERING SYSTEM & A DRAIN. 6. BACKWASH SHALL BE DISPOSED OF IN AN APPROVED MANNER. ENGINEERING DETAILS PRIOR TO CONSTRUCTION. EXPANSIVE SOIL DETAILS ARE VALID #3 0 12" ONLY FOR STATED EQUIVALENT FLUID PRESSURES AND POOL ENGINEERING INC. WHERE REQUIRED ALL PNEUMATIC CONCRETE PLACEMENT SHALL BE INSPECTED BY A SPECIAL #3 0 12" - RECOMMENDS THAT THE OWNER OR CONTRACTOR OBTAIN A SOILS REPORT. INSPECTOR IN CONFORMANCE WITH CBC SECTION 1704, WHO SHALL SUBMIT A STATEMENT #3 0 12- PLIS 3. THIS PLAN INDICATING COMPLIANCE PATH THE PLANS AND SPECIFICATIONS. ANS NOT VALID WITHOUT ADDITIONAL SURCHARGE DETAILS WHEN THE 7, POOL/SPA WATER HEATER AND GAS PIPING INSTALLATION TO BE IN CONFORMANCE PATH THE CPC. CONDITIONS AS SHOWN IN DETAIL #3 APPLY (PER CBC SECTION 1808.7.3). ALL POOLS 'TITLE 24 4" SHALL COMPLY WITH SLOPE SETBACKS PER CBC SECTION 1808.7.3. _ 4. THE STANDARD POOL STRUCTURAL PLAN IS NOT INTENDED TO BE APPLICABLE TO 1. PUMPS SHALL BE SIZED PER SECTION 150(p) OF THE 2013 BUILDING ENERGY EFFICIENCY - NON- STRUCTURAL ITEMS INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, STANDARDS. SECTION FENCING, CONCRETE DECKING AND POOL GEOMETRICS. 2. MANDATORY REQUIREMENTS FOR POOL & SPA HEATING SYSTEMS & EQUIPMENT: 2 5. DECKING CONSTRUCTION IS SHOWN AS RECOMMENDED MINIMUM CONSTRUCTION AND 1.1. SYSTEM IS CERTIFIED WITH: THERMAL EFFICIENCY THAT COMPLIES WITH THE N.T.S. DOES NOT DEMONSTRATE A SYSTEM THAT WILL RESIST HEAVING DUE TO SOIL APPLIANCE EFFICIENCY REGULATIONS, READILY ACCESSIBLE ON-OFF SWITCH, 8. CONTRACTORADMSED REFER TO OF THE CALIFORNIA HEALTH & EXPANSION'. WEATHERPROOF OPERATING INSTRUCTIONS ON ENERGY EFFICIENT OPERATIONS, NO 4" 6. ALL CONSTRUCTION MALL COMPLY WITH THE 2013 EDITIONS OF THE CALIFORNIA ELECTRIC RESISTANCE HEATING AND NO PILOT LIGHT. 6'0" 3%" BUILDING CODE (CBC), CALIFORNIA ELECTRICAL CODE (CEC), CALIFORNIA MECHANICAL 1.2. SYSTEM IS INSTALLED WITH: - - CODE (CMC), CALIFORNIA PLUMBING CODE (CPC), CAUFORNIA ENERGY CODE, 2013 A) AT LEAST 36" PIPE BETWEEN FILTER & HEATER FOR FUTURE SOLAR HEATING. .... BUILDING ENERGY EFFICIENCY STANDARDS, 2013 CALIFORNIA GREEN BUILDING B) COVER FOR OUTDOOR POOLS OR OUTDOOR SPA. SAFETY CODEIS FOR PROPEROINSTALLA INSTALLATIONION THEPOOL15928 DRAIN SYSTE 9. A REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER (RP DEVICE) IS REQUIRED ON STANDARDS CODE, AND LOCAL ORDINANCES. 1.3. POOL SYSTEM HAS DIRECTIONAL INLETS & A CIRCULATION PUMP TIME SWITCH TO ....... 7. POOLS WITH DIVING BOARDS SHALL MEET DIVING BOARD MANUFACTURER'S POOL PERMIT OFF PEAK OPERATION. 6" GEOMETRIC STANDARDS ANOR8. FENCING AND 7'0" 5" SIGNS & SAFETY EQUIPMENT SHALLLCAL BE INSTALLED IN ACCORDANCE WITH LOCAL CODES. BARRIERS #3 0 4" ......... 9. PUBLIC POOLS REQUIRE COUNTY HEALTH DEPARTMENT APPROVAL AND PROVISIONS FOR 1. PRIOR TO FILUNG, THE POOL AND OR SPA SHALL BE COMPLETELY ENCLOSED BY 5' MIN. ASSISTIVE DEVICES FOR THE DISABLED. ALL SWIMMING POOL AND SPA FILLERS PER CPC 603.4.22 THAN HIGH FENCING &GATES WITH NO OPENINGS GREATER THAN 4`. GATES TO BE 10.CONTRACTOR OR OWNER SHALL VERIFY ALL FIELD CONDITIONS & DIMENSIONS AT JOB 6" SITE. POOLLENGTH, GRADE BREAK LOCATIONS &DEPTH DIMENSIONS AS NOTED ON THE SELF-CLOSING & SELF -LATCHING WITH LATCH A MIN. 5' HIGH. ACCESS GATES TOE OF SLOPE OR OTHER SURCHARGE CONDITIONS (SEE GENERAL NOTES #3) PLOT PLANT! SHALL COMPLY WITH APSP SUGGESTED MINIMUM STANDARDS FOR THROUGH FENCING SHALL OPEN AWAY FROM THE POOL. MAXIMUM VERTICAL CLEARANCE PROVIDE ADEQUATE DRAINAGE BOND BEAM PER BEHIND POOL WALL. RESIDENTIAL POOLS APPLICABLE STATE AND LOCAL HEALTH DEPARTMENTS FROM GROUND TO POOL FENCING SHALL NOT EXCEED 2 INCHES. WHERE THIS VARIES FROM STRUCTURAL NOTES i. SOIL SHALL HAVE A MINIMUM BEARING VALUE OF 1500 PSF CONCRETE SHALL BE A LOCAL CODES, THE LOCAL CODES SHALL PREVAIL REGULATIO@IS AND MANUFACTURERS RECOMMENDATIONS. 8%- ELECTRICAL AND PLUMBING CITY OF FREMONT SPECIAL NOTES 10. ALL INTERIOR SURFACES OF POOL/SPA SHALL BE COATED WITH A WATER -TIGHT 1. ALL ELECTRICAL SHALL BE IN CONFORMANCE WITH THE 2013 CEC. THESE NOTES ARE ONLY APPLICABLE IN THE CITY OF FREMONT. 2. POOL SHELL AND PERIMETER PAVED AND UNPAVED SURFACES SHALL BE BONDED IN 8" 1. SEPARATE GRADING PERMIT IS REQUIRED FOR SWIMMING POOL INSTALLATION AT SLOPED ACCORDANCE WITH CEC B 680.26 . () BONDING TO PERIMETER SURFACES SHALL BE SITE. GRADING PLAN SHALL BE PREPARED, STAMPED AND SIGNED BY A LICENSED CIVIL 9'0" 8' PROVIDED AS SPECIFIED IN CEC 680.26(8)(2)(A) OR (2)(B) AND SHALL BE ATTACHED ENGINEER IN THE STATE OF CALIFORNIA. - - TO THE POOL REINFORCING STEEL OR COPPER CONDUCTOR GRID AT A MINIMUM OF 2. MINIMUM DISTANCE BETWEEN EXTERIOR WALL OF ADJACENT BUILDING & SWIMMING POOL - - FOUR (4) POINTS UNIFORMLY SPACED AROUND THE PERIMETER OF THE POOL SHALL BE 3'-0' WIDE WALKWAY PLUS THE WIDTH OF SWIMMING POOL BOND BEAM AND NO 101 3. OBTAIN ELECTRICAL AND PLUMBING PERMITS ALONG WITH POOL BUILDING PERMIT. LESS THAN THE DEPTH OF THE POOL ADJACENT TO THE BUILDING. REFER TO STANDARD 5 -FEET. BALANCED AND SYMMETRICALLY PLUMBED THROUGH "T' IC EXPANSIVE WALL DOES NOT REQUIRE (C N ED). * IF POOL WALL HEIGHT DOES NOT EXCEED 5'-0" THEN NO ADDITIONAL IN COTES DISTANCE DOWN FROM TOP OF BUILDING FOOTING WALL TO INCREASE SHOTCRETE COVER AND SURCHARGE 4. ALL EQUIPMENT SHALL BE LISTED AND INSTALLED PER MANUFACTURERS RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL REGULATIONS. POOL STRUCTURAL PLAN, DETAIL #2 3. FOR COMMERCIAL POOLS, HEALTH DEPARTMENT SUBMITTAL PLANS SHALL ACCOMPANY THIS 65 P.C.F. FITTINGS. DRAINS SHALL SEPARATED BY THREE FEET IN ANY DIMENSION. SEE ELECTRICAL AND PLUMBING NOTE 8. VERTICALC STEEL SURCHARGE DETAIL) BARS ARE REQUIRED. (DOES NOT APPLY TO SUPPLEMENT DETAILS) ADD ADDITIONAL REINF. BARS. 5. POOLS SHALL BE EQUIPPED WITH A FILTERING SYSTEM & A DRAIN. 6. BACKWASH SHALL BE DISPOSED OF IN AN APPROVED MANNER. STRUCTURAL PLAN INDICATING ALL REQUIREMENTS OF THE CBC AND COUNTY HEALTH DEPARTMENT FOR PUBLIC SWIMMING POOLS. #3 0 12" 3" #3 0 12" - 3" #3 0 12- 1. FOR E.F.P. = 65 P.C.F., CONC. COVER = C + 2' 7, POOL/SPA WATER HEATER AND GAS PIPING INSTALLATION TO BE IN CONFORMANCE PATH THE CPC. CITY OF ROCKLIN SPECIAL NOTES 4" 4'6"3" _ 3' " - TYPICAL LONGITUDINAL SECTION N.T.S. 2 STANDARD WALL SECTION N.T.S. 1 8. CONTRACTORADMSED REFER TO OF THE CALIFORNIA HEALTH & TH1. ESE ETNO IN RO KN, 4" 6%" 6'0" 3%" - - - 5' .... _....... SAFETY CODEIS FOR PROPEROINSTALLA INSTALLATIONION THEPOOL15928 DRAIN SYSTE 9. A REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER (RP DEVICE) IS REQUIRED ON ABSENCE OF A SITE SOILS INVESTIGATION, SWIMMING POOL AND SPA CONSTRUCTION SHALL CONFORM TO STANDARD POOL STRUCTURAL PLAN STEEL AND ....... 6'6" 4" 6" TOP OF 7'0" 5" 6" #3 0 4" ......... 81h" ALL SWIMMING POOL AND SPA FILLERS PER CPC 603.4.22 GUNITE SCHEDULES FOR HIGH EXPANSIVE SOIL WITH A MINIMUM SOIL EQUIVALENT FLUID 6" SPECIAL DETAIL REQUIRED WHEN LESS THAN 10' SLOPE TOE OF SLOPE OR OTHER SURCHARGE CONDITIONS (SEE GENERAL NOTES #3) NOTE: WHEN ACTUAL SITE CONDITIONS EXCEED THE LIMITATIONS BELOW OR ADDITIONAL PROVIDE ADEQUATE DRAINAGE BOND BEAM PER BEHIND POOL WALL. p TABLE NO. 5 RAISED BOND BEAM STRUCTURAL NOTES i. SOIL SHALL HAVE A MINIMUM BEARING VALUE OF 1500 PSF CONCRETE SHALL BE PRESSURE OF 65 P.C.F. (SCHEDULES C AND G). 2. CONCRETE SHALL BE PLACED AGAINST UNDISTURBED SOIL OR CERTIFIED FILL COMPACTED TO A MINIMUM OF 90% OF THE MAXIMUM DRY DENSITY IN ACCORDANCE WITH ASTM D1557 8%- SURCHARGES NOT COVERED BY THIS PLAN ARE PRESENT, ADDITIONAL TABLE #1 & DETAIL #12 1/4" PER SURCHARGE DETAILS ARE REQUIRED.01 M FO�T. SPECIAL DETAIL REQUIRED 1. WHEN LESS THAN POOL DEPTH OR H/4 T o a (1) #4 0 TOP x� a m w m SPECIAL DETAIL REQUIRED (7.5' MAX. H/4) o 0 o ''<- WATERPROOFING RECOMMENDED. HORIZ. STEEL m WHEN LESS THAN H/6 BARS 0 12" O.C. 1 W N M 3 6" C.M.U. W/ (10' MIN., 20' MAX.) N "'-¢� 0 1 SOLID GROUT. 3 VERT. BAR ®24" O.C. ALTERNATIVE BOND -Y- a o .._..._. I PER C.B.C. SECTION 1808.7.3 BEAM LOCATION WAR ~ BOND BEAM Z VERT. Slln LINE. VERTICAL STEEL W/ SURCHARGE CONDITIONS - ADDITIONAL SPECIAL DETAILS N.T.S. 3SEEmu� s �; F OR G 24" MIN. EMBED. REQUIRED FOR CONDITIONS ABOVE 3" ,C, TYP. HORIZ. STEEL U REFER TO AMERICAN NATIONAL STANDARD FOR RESIDENTIAL IN -GROUND SWIMMING POOLS PUBLISHED BY CLR. 'C' LL L 3" AMERICAN NATIONAL STANDARD INSTITUTE (ANSI) AND THE NATIONAL SPA & POOL INSTITUTE (APSP) �r77.. 7-CLR. o BEACH ENTRY STEEL AND SHOTCRETE SHALLOW SHELF (REEF) MASONRY NOTES: a (GUNITE) THICKNESS PER 1. CONCRETE BLOCK SHALL BE GRADE N (EXPOSED TO WEATHER), TYPE II (NON -MOISTURE o APPROPRIATE WALL CONTROLLED), NORMAL WEIGHT UNITS (135 PCF), CONFORMING TO CBCABC SEC. 2103, AND Ic! SCHEDULE. I ASTM C 90. ALL CONCRETE BLOCK SHALL HAVE A DESIGN STRENGTH OF fm = 1500 si. Z 2. GROUT SHALL CONFORM TO CBC/IBC SEC. 2103 & ASTM C 476 WITH fc=2,000 PSI. POOL FLOOR THICKNESSm ! SEE CBC/IBC TABLE 2103.12 FOR PROPORTIONS OF INGREDIENTS. MAY VARY TO ACHIEVE ? �. ao DESIRED WATER DEPTH. __ __ 3. MORTAR SHALL BE TYPE M WITH fc = 1800 psi AND SHALL CONFORM TO CBC/IBC SEC. 2103 & ASTM C 270. SEE CBCABC TABLES 2103.8(1),(2) FOR PROPORTION AND PROPERTY co - a I SPECIFICATIONS. NON -EXPANSIVE E EXPANSIVE NO DECK/HIGH EXP. F G E.F.P. 30 P.C.F. 45 P.C.F. 65 P.C.F. D C VERTICALC STEEL 2. ALL REINFORCING STEEL SHALL BE DEFORMED BARS &CONFORM TO ASTM A615 GRADE 1. ENGINEER TO SPECIFY TABLES AND DETAILS THAT APPLY TO A SPECIFIC JOB BY ONE OF VERTICAL STEEL C VERTICAL STEEL 3'6" 3" #3 0 12" 3" #3 0 12" - 3" #3 0 12- 4'0" 3" - - 3" 4" 4'6"3" _ 3' " - 536- '"5'0" 5'0-3" #3 0 6" 3%" #3 0 6" 534" #3 0 6- - 5-6- 3' 4" 6%" 6'0" 3%" - - - 5' .... _....... 7% ..... ....... 6'6" 4" 6" B+„ � 7'0" 5" 6" #3 0 4" ......... 81h" #3 0 3" 7'6" 5%" 6" 8W 8'0' 6%' BUILDING OIFFICIAL. 7" 9. KEEP CONCRETE DAMP CONTINUOUSLY FOR 14 DAYS. 8%- 10. ALL INTERIOR SURFACES OF POOL/SPA SHALL BE COATED WITH A WATER -TIGHT 8'6" 7366" 8" 916" 9'0" 8' - - 9" - - - - - - 101 - - 5 -FEET. 9'6" 9' 110 " 10'0" 9" 1 T 11 12%" 11'0" 9" 3. DO NOT USE BLACK RUBBER HOSE WHEN FILLING POOL (IT MARKS THE PLASTER). - 11" 13" SEE STRUCTURAL NOTE #1 SHALLOW FEATURES MAINTAIN 18" MIN. EMBEDMENT INTO N.T.S. 4 RAISED BOND BEAM N.T.S. BY THE USE OF THIS PLAN, THE USER ACKNOWLEDGES THAT HE UNDISTURBED OR 90% COMPACTED SOIL rJ NOTES HAS READ & UNDERSTANDS ALL OF THE NOTES INCLUDED HEREIN. r67 NOTE: BOND BEAM PER TABLE9" & LARGER BRICK OR PRECAST PROPERTY RIGHTS TO ALL DRAWINGS, REPRESENTATIONS, V-8" SPA AIR -LINE NO. 1 & DETAIL 12. -�`- -- 2" 2 CONCRETE COPING. 9 2 �- 3RD AND/OR 4TH IDEAS DETAILS, NOTES &SPECIFICATIONS EITHER COPIES MAY BE LOOPED ���'''�'''''� # / " / OR ORIGINALS THEREOF THAT MAY BE INCORPORATED INTO INTO SPA BOND c�� EXPANSION JOINT & SEALANT to 12' BAR LOCATION THIS DESIGN ARE THE PROPERTY sOIEY of POOL ��sn ' r-� "�'-- -� MAY VARY TO ENGINEERING, INC. PERMISSION FOR ANY COPIES OF SAID z �- -�== $ � � � LEVEL TOP OF GUNITE 4'-0" MIN. REQ'D. FOR EXPANSIVE SOILS. � BEAM. MAINTAIN X o (2) #3 X 4 3 BARS COPYRIGHTED MATERIALS, DRAWINGS, REPRESENTATIONS, ¢ z # l , ¢ �_ , O # W/ GROUT &PLACE PER DETAIL #8 1 PROVIDE 2 1/2' 1" CLR. TO REINF. ¢ 3 BARS. M IDEAS, DETAILS, AND SPECIFICATIONS EITHER ORIGINAL OR 6" ai - #15 FELT OR 4 MIL. DECKING F- ELECTRICAL 'J' BOX. CLR. BETWEEN COPIES THEREOF TO BE MADE, COPIED OR ALTERED BY w I THICK x 3 BARS 1" MIN. CLR. s PARALLEL BARS. ANY PERSON, BUSINESS OR CORPORATION MAY ONLY BE 13. SPA LIGHT ¢ # € AROUND ALL VISQUEEN ON TOP. COPING 8" MIN. ABOVE DECK, WATER / O # 12" O.C. N , , a " FINISH BOND BEAM W 4 3 BARS DECKING. AUTHORIZED WITH THE EXPRESSED WRITTEN PERMISSION EA. WAY. PIPES. #3 BARS 12" � rA E -LINE OR FLOOD LINE WHICH GRADE. PER TABLE #1 &DETAIL #12. j TILE OF POOL ENGINEERING, INC. BY THE USE OF THIS PLAN, _vru � .1. ` SKIMMER BOND BEAM PER TABLE NO. 1. UNDERSTANDS ALL OF THE NOTES INCLUDED HEREIN. -� WATER O.C. EA. WAY. zCEVER IS GREATER }( PLUMBING MAY BE LOCATED THE USER ACKNOWLEDGES THAT HE HAS READ & EQ. EQ. WATER n r 1 LINE. 24" COVER. �� - 1� I L. IN BOND BEAM LOWER CORNER BOND BEAM HORIZONTAL REINFORCING PER DETAIL 10. 6" LINE. p # LAP (2) #3 BARS Z 2 1/2" MAINTAIN 1" CLR. TO REINF. 3" BARS MAY BE OVER OR CALLS BY: A.J.C. NOT REQUIRED IF 6" MIN. MIN. V�V \ COMPACTED ci CLR. UNDER VERTICAL BARS. CLEAR PROVIDED. BEND �� I FILL CLR. X c W DRAWN BY: T.L.L. z 5" MIN. �� BOND `�� I L sy , 1 o NN PRECAST COPING OR BRICK 24" MIN. LAP c m ,,, 9� z # i 1 AROUND ALL. UNNDER •`��� - - �o�� 0 3 ®� 8"* CHECKED BY: R.L.L. CIRCULATION DRAINS: r INTO SPA FLOOR 3 BARS " PROVIDE (2) ANTI -VORTEX SUCTION OUTLETS PER PUMP, I: OR POOL WALL 0 12 "O.C. (2) #3 'Z' BARS ) SKIMMER. �� ¢ Fti 1 �N• a o a � ._ . • -�i� �=- #8 COPPER \ D M COVERED WITH APPROVED A.S.M.E. STANDARD A112.19.8 EA. WAY. ���` � 6 m „� (2) #3 BARS ANTI -ENTRAPMENT GRATES, THAT ARE HYDRAULICALLY GROUND WIRE r o \ ffk c=i, : CL VENEER. BALANCED AND SYMMETRICALLY PLUMBED THROUGH "T' DAM WALL 6' DAM_ - LAP INTO SPA REINF. SECTION AT SKIMMER L 'Ld C.E.C. APPROVED `D O \ _ - 4O o BEND FITTINGS. DRAINS SHALL BE SEPARATED BY THREE FEET IN HORIZ. BAR 12• DAM -LAP INSIDE BARS INTO SPA REINF. J FIXTURE FFA _ _ - Ino VERT. STEEL PROF S$/0 ANY DIMENSION. SEE ELECTRICAL AND PLUMBING NOTE 8. LAP SPLICE:: - LAP OUTSIDE BARS INTO POOL REINF. 24" CONDUIT. LENS �F - - - - yo 45' OR 90'. �0 N MI". LIGHT. SED �A J ? BOND BEAM PERS STILE SPA DETAILS MAY BE USED Pool MIN. (2) #3 BARS �9 a� °' LAP EACH WAY l ," 'o P TABLE NO. 1. (-PLASTER r� SPA DETAILS - N.T.s. 7 IP FOR SPAS WITHOUT POOLS. AROUND NICHE. 18" MIN.p`� r`i'r C' 6 6 m - C LAP, TYP•IROCK OR BRICK NOTCH P 6/3012 7 4'-0" MIN. IMPERVIOUS DECK a APPROVED SEALANT SLOPE 1/8"-1/4' INSTALL PER MANUFACTURER I L `` VERT. STEEL WOOD POST FROM `r CMI. S 3 1/2' PER DRAIN 0 (2) #3 BARS. #3 0 6" O.C. ATTACHED PATIO COVER OR CAl1F0�� NOTES: 5'-0" DEEP & BELOW. MAX. DEAD + LIVE LOAD = 2000 Ib. X N 1. INSTALL NO. 8 COPPER GROUND HARE FROM LIGHT NICHE TO OR 60 I I LEVEL TOP OF BOND BEAM LU >< NOTE: BRASS CONDUIT TO POOL REBAR, OR NON-METALUC HORIZONTAL STEEL ROCK ON ND BEAM. N `''' SATURATION ''" PROVIDE CONTROL JOINTS 3" CLR. �"M _ 5" MIN. #3 BARS 0 12" O.C. TYP. M ► I WITH GROUT &PLACE 15# C) a ). CONDUIT CAN BE USED HATH INSULATED NO. 8 COPPER WIRE L FELT OR 4 MIL. VISQUEEN ON v o I RECOMMENDED WHERE APPROPRIATE. TYPICAL TYPICAL GALV. SIMPSON POST BASE. I INTERIOR W/ APPROVED POTTING COMPOUND PER THE C.E.C.OP OF BOND BEAM. PLAN VALID ONLY WITH WET it `` I PRIOR TO - Y NOTE BOND PER ELECTRICAL & } :y n L i POURING DECK. = � 1' 2 SWIMMING POOL LIGHTING FIXTURES STALL COMPLY WITHEXTRA REINFORCING TO EXTEND PLUMBING NOTE 2. STAMP & ENGINEER'S SIGNATURE R 6' REMAINDER OF JOINT IN STYROFOAM OR PLAN AT SKIMMER APPLICABLE UNDERWRITERS' LABORATORIES REQUIREMENTS 24" MIN. EACH SIDE OF RAMP. IN RED INK ON PLAN. SEE ELECTRICAL AND MASTIC $ ' OTHER EXP. MATERIAL. CONCRETE SHALL FOR LIGHTING FIXTURES U.L STANDARD 676. 3 1 2 MIN. CONC. DECKING. T •) s AUTHORIZED SIGNATURES: PLUMBING NOTE #2 REGARDING FOOTING RECOMMENDED NOT TOUCH COPING, BOND BEAM OR / . EQUIPOTEN11AL BONDING GRID FOR EXPANSIVE SOILS. TILL RONALD L LACHER, P.E. ADJACENT STRUCTURES.. CANTILEVER CONCRETE TODD L LACHER, P.E. IN EXPANSIVE SOILS WHERE MIN DECK REQMTS KRISTOF NADASDI, P.E. EXPANSIVE SOIL DETAILS ARE NOT MET USE TABLE 1, SCHEDULE 'C' N.T.S. 8 SKIMMER DETAIL N.T.S. 9 l SECTION AT LIGHT N.T.S. 10 SHALLOW/DEEP END RAMP ja BOND BEAM DETAILS N.T.S. 12 JEFFERY COLLINS, P.E. CHRIS BIEDENBACH, P.E. SHEET: STANDARD PLAN APPROVALS: pool Ron Lacher, R.C.E. s STANDARD POO PREPARED IN ACCORDANCE WITH engineering 1201 N. Tustin Ave. THE 2013 CALIFORNIA BUILDING CODE g 9 Anaheim, California 92807 STRUCTURAL PLAN (2012 INTERNATIONAL BUILDING CODE) Inc. Fax: (714) 630-6114 Phone: (714) 630-6100 'IONIC Cis^tl ' 7 PLACED AGAINST UNDISTURBED SOIL OR BUILDING DEPARTMENT APPROVED 90% COMPACT FILL THIS PLAN IS NOT SUITABLE WHERE POTENTIAL EXISTS FOR CITY OF SAN JOSE SPECIAL NOTES DIFFERENTIAL MOVEMENT FROM DISSIMILAR SOIL CONDITIONS UNDER POOL, SUCH AS THESE NOTES ARE ONLY APPLICABLE IN THE CITY OF SAN JOSE. CUT -FILL TRANSITIONS. 2. ALL REINFORCING STEEL SHALL BE DEFORMED BARS &CONFORM TO ASTM A615 GRADE 1. ENGINEER TO SPECIFY TABLES AND DETAILS THAT APPLY TO A SPECIFIC JOB BY ONE OF THE FOLLOWING METHODS: 40 FOR #3 BARS AND #4 BARS. SPLICES TO BE LAPPED A MINIMUM OF 24". MINIMUM THE SITE PLAN STAMPED AND SIGNED BY THE ENGINEER REFERRING TO THE CLEARANCE BETWEEN PARALLEL BARS IS 2 1/2'. APPROPRIATE DETAILS AND SCHEDULES. 3. (1) #4 BAR IS EQUIVALENT TO AND MAY BE USED IN PLACE OF (2) #3 BARS, WITH B. A LETTER STAMPED AND SIGNED PROVIDED THE SAME INFORMATION. THE EXCEPTION THAT IF #4 BARS ARE USED FOR THE BASIC GRID, THE MAXIMUM C. A STANDARD POOL PLAN NTH THE ADDRESS WRITTEN IN BY THE ENGINEER ALSO SPACING IS #4 BARS AT 18' O.C.. IDENTIFYING SCHEDULES AND DETAILS. 4. THE PLAN 'TABLES SPECIFY THE MINIMUM REQUIRED REINFORCEMENT. FOR CONVENIENCE 2. SWIMMING POOL AND SPA CONSTRUCTION SHALL CONFORM TO STANDARD POOL OF THE INSTALLER THERE MAY BE MORE REINFORCEMENT THAN SPECIFIED AT ANY STRUCTURAL PLAN STEEL AND GUNITE SCHEDULES WITH A MINIMUM SOIL EQUIVALENT GIVEN POINT IN THE POOL STRUCTURE. FLUID PRESSURE OF 45 P.C.F. FOR EXPANSIVE SOIL (UNITED SOIL CLASSIFICATIONS GW, 5. BONDING/GROUNDING (PER THE CEC) OF THE STRUCTURAL REINFORCING MUST BE GP, GM, GC, SW, SP, SM, SM -SC, ML). AN EQUIVALENT FLUID PRESSURE OF 30 PCF, INSTALLED PRIOR TO PLACEMENT OF CONCRETE. NON -EXPANSIVE SOIL, MAY ONLY BE USED IF RECOMMENDED BY A SOILS ENGINEER. 6. SHOTCRETE'. (GUNITE) TO BE IN CONFORMANCE NTH CBC SECTION 1910 & SHALL HAVE 3. OVER THE COUNTER PERMITS ARE NOT POSSIBLE IN AREAS DESIGNATED AS 'SPECIAL A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS. WHERE APPLICABLE, GEOLOGICAL HAZARD.' THE MASTER PLAN MIGHT BE USEABLE BASED ON THE FINDINGS OF SHOTCRETE, (GUNITE) TO BE IN CONFORMANCE WITH CBC SECTION 1904 DURABILITY THE GEOLOGIC AND GEOTECHNICAL REPORTS. REQUIREMENTS. 4. IN ACCORDANCE WITH CBC SECTION 1802.2.7, A SITE SPECIFIC SOILS INVESTIGATION MAY 7. CEMENT SHIALL CONFORM TO CBC SECTION 1903.1, ACI 318 SECTION 3.2, ASTM C 150. BE REQUIRED FOR PROJECTS LOCATED IN SEISMIC DESIGN CATEGORIES D, E, OR F. ` 8. SHOTCRETEjGUNITE IN CONTACT WITH SOIL SHALL BE IN ACCORDANCE WITH ACI 318 SECTION 4.:3 FOR CONCRETE EXPOSURE TO SULFATE AND AS DIRECTED BY LOCAL BUILDING OIFFICIAL. 9. KEEP CONCRETE DAMP CONTINUOUSLY FOR 14 DAYS. 10. ALL INTERIOR SURFACES OF POOL/SPA SHALL BE COATED WITH A WATER -TIGHT i SURFACE. 11. FLOOR TO (WALL TRANSITION RADIUS MAY VARY DEPENDING ON CONTRACTOR OR OWNER DESIGN INTENT. RADIUS SHALL NOT BE LESS THAN 1 -FOOT AND SHALL NOT EXCEED 5 -FEET. OWNER 1. KEEP SHOT(CRETE (GUNITE) DAMP CONTINUOUSLY FOR 14 DAYS AFTER INSTALLATION. 2. DO NOT TURN ON LIGHT WHEN POOL IS EMPTY. 3. DO NOT USE BLACK RUBBER HOSE WHEN FILLING POOL (IT MARKS THE PLASTER). SEE STRUCTURAL NOTE #1 SHALLOW FEATURES MAINTAIN 18" MIN. EMBEDMENT INTO N.T.S. 4 RAISED BOND BEAM N.T.S. BY THE USE OF THIS PLAN, THE USER ACKNOWLEDGES THAT HE UNDISTURBED OR 90% COMPACTED SOIL rJ NOTES HAS READ & UNDERSTANDS ALL OF THE NOTES INCLUDED HEREIN. r67 NOTE: BOND BEAM PER TABLE9" & LARGER BRICK OR PRECAST PROPERTY RIGHTS TO ALL DRAWINGS, REPRESENTATIONS, V-8" SPA AIR -LINE NO. 1 & DETAIL 12. -�`- -- 2" 2 CONCRETE COPING. 9 2 �- 3RD AND/OR 4TH IDEAS DETAILS, NOTES &SPECIFICATIONS EITHER COPIES MAY BE LOOPED ���'''�'''''� # / " / OR ORIGINALS THEREOF THAT MAY BE INCORPORATED INTO INTO SPA BOND c�� EXPANSION JOINT & SEALANT to 12' BAR LOCATION THIS DESIGN ARE THE PROPERTY sOIEY of POOL ��sn ' r-� "�'-- -� MAY VARY TO ENGINEERING, INC. PERMISSION FOR ANY COPIES OF SAID z �- -�== $ � � � LEVEL TOP OF GUNITE 4'-0" MIN. REQ'D. FOR EXPANSIVE SOILS. � BEAM. MAINTAIN X o (2) #3 X 4 3 BARS COPYRIGHTED MATERIALS, DRAWINGS, REPRESENTATIONS, ¢ z # l , ¢ �_ , O # W/ GROUT &PLACE PER DETAIL #8 1 PROVIDE 2 1/2' 1" CLR. TO REINF. ¢ 3 BARS. M IDEAS, DETAILS, AND SPECIFICATIONS EITHER ORIGINAL OR 6" ai - #15 FELT OR 4 MIL. DECKING F- ELECTRICAL 'J' BOX. CLR. BETWEEN COPIES THEREOF TO BE MADE, COPIED OR ALTERED BY w I THICK x 3 BARS 1" MIN. CLR. s PARALLEL BARS. ANY PERSON, BUSINESS OR CORPORATION MAY ONLY BE 13. SPA LIGHT ¢ # € AROUND ALL VISQUEEN ON TOP. COPING 8" MIN. ABOVE DECK, WATER / O # 12" O.C. N , , a " FINISH BOND BEAM W 4 3 BARS DECKING. AUTHORIZED WITH THE EXPRESSED WRITTEN PERMISSION EA. WAY. PIPES. #3 BARS 12" � rA E -LINE OR FLOOD LINE WHICH GRADE. PER TABLE #1 &DETAIL #12. j TILE OF POOL ENGINEERING, INC. BY THE USE OF THIS PLAN, _vru � .1. ` SKIMMER BOND BEAM PER TABLE NO. 1. UNDERSTANDS ALL OF THE NOTES INCLUDED HEREIN. -� WATER O.C. EA. WAY. zCEVER IS GREATER }( PLUMBING MAY BE LOCATED THE USER ACKNOWLEDGES THAT HE HAS READ & EQ. EQ. WATER n r 1 LINE. 24" COVER. �� - 1� I L. IN BOND BEAM LOWER CORNER BOND BEAM HORIZONTAL REINFORCING PER DETAIL 10. 6" LINE. p # LAP (2) #3 BARS Z 2 1/2" MAINTAIN 1" CLR. TO REINF. 3" BARS MAY BE OVER OR CALLS BY: A.J.C. NOT REQUIRED IF 6" MIN. MIN. V�V \ COMPACTED ci CLR. UNDER VERTICAL BARS. CLEAR PROVIDED. BEND �� I FILL CLR. X c W DRAWN BY: T.L.L. z 5" MIN. �� BOND `�� I L sy , 1 o NN PRECAST COPING OR BRICK 24" MIN. LAP c m ,,, 9� z # i 1 AROUND ALL. UNNDER •`��� - - �o�� 0 3 ®� 8"* CHECKED BY: R.L.L. CIRCULATION DRAINS: r INTO SPA FLOOR 3 BARS " PROVIDE (2) ANTI -VORTEX SUCTION OUTLETS PER PUMP, I: OR POOL WALL 0 12 "O.C. (2) #3 'Z' BARS ) SKIMMER. �� ¢ Fti 1 �N• a o a � ._ . • -�i� �=- #8 COPPER \ D M COVERED WITH APPROVED A.S.M.E. STANDARD A112.19.8 EA. WAY. ���` � 6 m „� (2) #3 BARS ANTI -ENTRAPMENT GRATES, THAT ARE HYDRAULICALLY GROUND WIRE r o \ ffk c=i, : CL VENEER. BALANCED AND SYMMETRICALLY PLUMBED THROUGH "T' DAM WALL 6' DAM_ - LAP INTO SPA REINF. SECTION AT SKIMMER L 'Ld C.E.C. APPROVED `D O \ _ - 4O o BEND FITTINGS. DRAINS SHALL BE SEPARATED BY THREE FEET IN HORIZ. BAR 12• DAM -LAP INSIDE BARS INTO SPA REINF. J FIXTURE FFA _ _ - Ino VERT. STEEL PROF S$/0 ANY DIMENSION. SEE ELECTRICAL AND PLUMBING NOTE 8. LAP SPLICE:: - LAP OUTSIDE BARS INTO POOL REINF. 24" CONDUIT. LENS �F - - - - yo 45' OR 90'. �0 N MI". LIGHT. SED �A J ? BOND BEAM PERS STILE SPA DETAILS MAY BE USED Pool MIN. (2) #3 BARS �9 a� °' LAP EACH WAY l ," 'o P TABLE NO. 1. (-PLASTER r� SPA DETAILS - N.T.s. 7 IP FOR SPAS WITHOUT POOLS. AROUND NICHE. 18" MIN.p`� r`i'r C' 6 6 m - C LAP, TYP•IROCK OR BRICK NOTCH P 6/3012 7 4'-0" MIN. IMPERVIOUS DECK a APPROVED SEALANT SLOPE 1/8"-1/4' INSTALL PER MANUFACTURER I L `` VERT. STEEL WOOD POST FROM `r CMI. S 3 1/2' PER DRAIN 0 (2) #3 BARS. #3 0 6" O.C. ATTACHED PATIO COVER OR CAl1F0�� NOTES: 5'-0" DEEP & BELOW. MAX. DEAD + LIVE LOAD = 2000 Ib. X N 1. INSTALL NO. 8 COPPER GROUND HARE FROM LIGHT NICHE TO OR 60 I I LEVEL TOP OF BOND BEAM LU >< NOTE: BRASS CONDUIT TO POOL REBAR, OR NON-METALUC HORIZONTAL STEEL ROCK ON ND BEAM. N `''' SATURATION ''" PROVIDE CONTROL JOINTS 3" CLR. �"M _ 5" MIN. #3 BARS 0 12" O.C. TYP. M ► I WITH GROUT &PLACE 15# C) a ). CONDUIT CAN BE USED HATH INSULATED NO. 8 COPPER WIRE L FELT OR 4 MIL. VISQUEEN ON v o I RECOMMENDED WHERE APPROPRIATE. TYPICAL TYPICAL GALV. SIMPSON POST BASE. I INTERIOR W/ APPROVED POTTING COMPOUND PER THE C.E.C.OP OF BOND BEAM. PLAN VALID ONLY WITH WET it `` I PRIOR TO - Y NOTE BOND PER ELECTRICAL & } :y n L i POURING DECK. = � 1' 2 SWIMMING POOL LIGHTING FIXTURES STALL COMPLY WITHEXTRA REINFORCING TO EXTEND PLUMBING NOTE 2. STAMP & ENGINEER'S SIGNATURE R 6' REMAINDER OF JOINT IN STYROFOAM OR PLAN AT SKIMMER APPLICABLE UNDERWRITERS' LABORATORIES REQUIREMENTS 24" MIN. EACH SIDE OF RAMP. IN RED INK ON PLAN. SEE ELECTRICAL AND MASTIC $ ' OTHER EXP. MATERIAL. CONCRETE SHALL FOR LIGHTING FIXTURES U.L STANDARD 676. 3 1 2 MIN. CONC. DECKING. T •) s AUTHORIZED SIGNATURES: PLUMBING NOTE #2 REGARDING FOOTING RECOMMENDED NOT TOUCH COPING, BOND BEAM OR / . EQUIPOTEN11AL BONDING GRID FOR EXPANSIVE SOILS. TILL RONALD L LACHER, P.E. ADJACENT STRUCTURES.. CANTILEVER CONCRETE TODD L LACHER, P.E. IN EXPANSIVE SOILS WHERE MIN DECK REQMTS KRISTOF NADASDI, P.E. EXPANSIVE SOIL DETAILS ARE NOT MET USE TABLE 1, SCHEDULE 'C' N.T.S. 8 SKIMMER DETAIL N.T.S. 9 l SECTION AT LIGHT N.T.S. 10 SHALLOW/DEEP END RAMP ja BOND BEAM DETAILS N.T.S. 12 JEFFERY COLLINS, P.E. CHRIS BIEDENBACH, P.E. SHEET: STANDARD PLAN APPROVALS: pool Ron Lacher, R.C.E. s STANDARD POO PREPARED IN ACCORDANCE WITH engineering 1201 N. Tustin Ave. THE 2013 CALIFORNIA BUILDING CODE g 9 Anaheim, California 92807 STRUCTURAL PLAN (2012 INTERNATIONAL BUILDING CODE) Inc. Fax: (714) 630-6114 Phone: (714) 630-6100 'IONIC Cis^tl ' 7