HomeMy WebLinkAboutB16-1094 056-270-023,NO - CON5TRUCTION TYPE V -B JOB DE50RIPTION: 1. REMOVE EXI5TING REAR PATIO. 2. FAMILY ROOM ADITION OF 16' X 32' TO THE REAR 51DE OF EX15TINC-7 DEYNELLING. 3. COVERED PORCH 4' X 16' AREA CALCULATIONS 1. EX15TING CONDITION TO 5QUARE FOOTAGE= 881 5Q. FT. 2. PROP05ED 5QUARE FOOTAGE = 512 3. TOTAL CONDITIONED 5QUARE FOOTAGE EQUAL5 13113 5Q. FT.2 4. TOTAL COVERED DECK 5QUARE FT = 64 FT.2 PLANS CONFORM TO THE 2013 CALIF. BUILDING CODE ( CBC) ,2013 CALIFORNIA RESIDENTIAL CODE (CRC), 2013 CALIFORNIA MECHANICLE CODE ( CMC ),2013 CALIFORNIA PLUMBING CODE ( CPC ), 2013 CALIFORNIA ELECTRICAL CODE ( CEC ), AND 2013 CALIFORNIA ENERGY CODE ( CM SYMBOLS KEY: � = WALL LINE A= SHEAR WALL SCH. # = CROSS SEC. / PG NUM. PG ® = FOUNDATION WALL/ DETAILS PG A = CONST. DETAIL / PG # Q � PERMIT BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR CODE COMPLIANCE DATE ��BY f- SCALE: 1 " = 20 FT. TITLE SITE PLAN N­Id'N0SN3oun tp unAAi= nJ=cfr-AIC ' CAD GENERATED HOUSE PLANS *3-D VEIWS `PULL PERM T SET'S DESIGNED HOW "YOU" LIKE JIM PEPPLER (530) 872-3339 HM,10FF (530) 514-3991 CELL PO BOX 1646 PARADISE CA 95967 SIGNED BY: DATE: v J uj c� W Z) >' o OC v cr n Z® U6 o� wa& 1 -- DATE: 4-14-16 CHK. 1 6-29-16 CHK 2 1-18-16 I ISI D EX SITE PLAN 9 FLOOR PLAN Z ELEVATIONS 3 FOUNDATION 4 ROOF PLM 4 SECTION 4 ELECTRICAL 3 STRUCTUAL S1 STRUCTUAL S2 STRUCTUAL S3 JUI 1 4040 1 -EX15TIN6 RE5IDENCE I PROP05ED ADDITION ROP R . LIVINO AREA r PLANS CONFORM TO THE 2013 CALIF. BUILDING CODE CBC 2013 CALIFORNIA RESIDENTIAL CODE CRC 2013 CALIFORNIA MECHANICLE CODE CMC 2013 CALIFORNIA PLUMBING CODE CPC 2013 CALIFORNIA ELECTRICAL CODE CEC AND 2013 CALIFORNIA ENERGY CODE CEC SYMBOLS KEY: � = WALL LINE A= SHEAR WALL SCH. # = PG CROSS SEC. / PG NUM. ® = FOUNDATION WALL/ DETAILS 0A = CONST, DETAILI PG # PG —1°9 PERMIT # y3 f BurrE COUNTY SERVICE REVIEWED FOR CODE C MPLIANCE DATE SOLE: 1/4 " - 1 FT. N-id'N0SN3pun(' /D Ljf-)AAC riccl II^A/fl 'CAD GENERATED HOUSE PLANS ' 3-0 VE1WS FULL PERMIT SETS DESIGNED HOW "YOU" LIKE JIM PEPPLER (530) 872-3339 HMIOFF (530) 514-3991 CELL PO BOX 1646 PARADISE CA 95967 SIGNED BY: Qu w 0 c. i IN Q Q cc uj Z) Q c 0 0 S REVISIONS DATE' 4-14-16 CHK. 1 6-29-16 CHK 2 7-18-16 INDEX SITE PLAN 1 FLOOR PLAN 2 ELEVATIONS 3 ! I f 4 -----! ----------- 4 ----------------- ----------------- -------------_.. -------------- -... 3 t o I I I II f STRUCTUAL II PATH I S2 ! II BEDROOM i II II m m I ! i ;i------------------ is 12'-0" a 0 - m il I 1 .--------------------------------------------------- --_ _................................. ------ . ----------------1---------------` --------------------------------, . i KITCHEN PATIO ! ! N LIVING ! I I ! I I ! ! I ......................1..----..... -- -------................... ............... -......................-------......------...... ..---------------- II I...--- ------------ —1 - I I a I I I I 4040 I !-_ -------------I------------- —1 24'-6" 711 12'-0" EX15TIN6 FOOTPRINT LIVING AREA JUI 1 4040 1 -EX15TIN6 RE5IDENCE I PROP05ED ADDITION ROP R . LIVINO AREA r PLANS CONFORM TO THE 2013 CALIF. BUILDING CODE CBC 2013 CALIFORNIA RESIDENTIAL CODE CRC 2013 CALIFORNIA MECHANICLE CODE CMC 2013 CALIFORNIA PLUMBING CODE CPC 2013 CALIFORNIA ELECTRICAL CODE CEC AND 2013 CALIFORNIA ENERGY CODE CEC SYMBOLS KEY: � = WALL LINE A= SHEAR WALL SCH. # = PG CROSS SEC. / PG NUM. ® = FOUNDATION WALL/ DETAILS 0A = CONST, DETAILI PG # PG —1°9 PERMIT # y3 f BurrE COUNTY SERVICE REVIEWED FOR CODE C MPLIANCE DATE SOLE: 1/4 " - 1 FT. N-id'N0SN3pun(' /D Ljf-)AAC riccl II^A/fl 'CAD GENERATED HOUSE PLANS ' 3-0 VE1WS FULL PERMIT SETS DESIGNED HOW "YOU" LIKE JIM PEPPLER (530) 872-3339 HMIOFF (530) 514-3991 CELL PO BOX 1646 PARADISE CA 95967 SIGNED BY: Qu w 0 c. i IN Q Q cc uj Z) Q c 0 0 S REVISIONS DATE' 4-14-16 CHK. 1 6-29-16 CHK 2 7-18-16 INDEX SITE PLAN 1 FLOOR PLAN 2 ELEVATIONS 3 FOUNDATION 4 ROOF PLN 4 SECTION 4 ELECTRICAL 3 STRUCTUAL S7 STRUCTUAL S2 STRUCTUAL S3 PG ki TITLE mmu"OR LIFA'N L -- - -- - ------------------ — J ELECTRICAL LEGEND SYMBOL DESCRIPTION a� METER SOCKET 3 PANEL. BOX 4 ROOF PLN 4 CEILING FAN WI LIGHT R RECESSED FLUORESCENT 3 LIGHT FIXTURE - }- 11 OV CEILING LIGHT FIXTURE 3 11 OV RECESSED LIGHT FIXTURE S4 11 OV SAVE LIGHT FIXTURE S2 STRUCTUAL NO 11 OV CHANDELIER LIGHT FIXTURE - \T Y 110V WALL. LIGHT FIXTURE - SINGLE POLE SWITCH THREE WAY SWITCH +R- FOUR WAY SWITCH V DIMMER SWITCH - OUTDOOR SWITCH 11 OV DUPLEX RECEPTACLE :016- ARC FAULT INTERRUPTED - 11 OV DUPLEX RECEPTACLE GROUND FAULT INTERRUPTED :0 :F 11 OV DUPLEX RECEPTACLE W,' WEATHERPROOF COVER ,I 11 OVFLOOR MOUNTED DUPLEX RECEPTACLE 240V RECEPTACLE < TELEPHONE JACKS TELEVISION JACKS DOOR BELL PUSH BUTTON _a THERMOSTAT s� SMOKE DETECTOR FEEEXHAUST FAN °' DOOR CHIME 0 FIRE ALARM PANEL. (D - COMPUTER POINT N 11 11 FEXI5TING RIGHT 51DE; ------------------------------------------ mm ELECTRICAL PLAN I 50ALE.................................114" = 1 FT. PERMIT #�-- sERVICEs BUTTEcRE�jEWED FOR CODE COMPLIANCE _ 1� --BY-- DATE�------ - -- SC,A.LE. 1 1 FLOOR PLAN 2 ELEVATIONS 3 FOUNDATION 4 ROOF PLN 4 SECTION 4 ELECTRICAL 3 STRUCTUAL S4 11� S2 STRUCTUAL S3 � GENERAL ELECT IGAL NOTES PER GEC 2010 1, ALL FIRE ALARMS SHOWING ARE TO INCLUDE CARBON MONOXIDE DETECTION, AND SHALL BE INTER- CONNECTED. 2. ALL RECEPTAC.LE5 FOR 120V, 51NGLF PHASE, 15 AND 20 AMP CIRCUITS MUST BE ARG- FAULT CIRCUIT - INTERRUPTER (AFCI) TYPE. 3, ALL RECEPTACLES FOR 120\1, 5IN6LE PHASE, 15 AND 20 AMP CIRCUIT5 MUST BE TAMPER- RE515TANT TYPE, 4. PROVIDE TWO OR MORE 20 AMP SMALL APPLIANCE BRANCH CIRCUITS EVENLY PROPORTIONED IN THE KITCHEN, PANTRY, BREAKFAST ROOM, OR 5;MILA.R AREA TO SERVE ALL WALL AND FLOOR AREAS. 5UCH CIRCUIT5 WP SHALL HAVE NO OTHER OUTLETS. 5. BATHROOMS RECEPTACLES SHALL BE SUPPLIED BY ONE 20 AMP CIRCUIT WITH NO OTHER OUTLETS. b. LAUNDRY ROOM RECEPTACLES SHALL BE SUPPLIED WITH ONE DEDICATED 20 AMP CIRCUIT WITH NO OTHER OUTLE'i 5. 1. FIXTURES, LAMPHOLDER5, AND RECEPTACLE OUTLETS MUST BE SECURELY SUPPORTED. A FIXTURE THAT WEI6H5 MORE THAN 6 LB5. OR EXCEEDS 16 INCHES IN ANY DIMEN51ON SHALL NOT BE SUPPORTED BY THE 5CREN SHELL OF A LAMP HOLDER PER 2010 GEC art. 410.30 (a) OUTLET BOXES SHALL NOT BE USED A5 THE 5OLE SUPPORT FOR CEILING (PADDLE) FANS PER 2010 CEG art. 314.2'7 (A) AND (O ). CALIFORNIA TITLE 24 COMPLIANCE -500/6 OF KITCHEN LIGHTING MIN. TO BE HISH EFFICACY. FLUORESCENT AND COMPACT FLUORESCENT FIXTURES I LITH ELECTRIC BALLAST SATISFY. -AT LEAST ONE LUMINAIRE INSTALLED IN EACH BATHROOM MUST BE OF THE HIGH -EFFICIENCY TYFE. ALL OTHER LI6HT5 INSTALLED IN THE BATHROOM MUST BE HIGH -EFFICIENCY OR CONTROLLED BY VACANCY SENSORS. CA. ENERGY CODE 150.0(K)5. - LIGHTING IN ATTACHED AND DETACHED GARAOE5, LAUNDRY ROOMS AND UTILITY ROOMS, SHALL HAVE HIGH EFFICIENCY LIGHTING AND BE CONTROLLED BY VACANCY SENSORS. -LIGHTING IN ALL OTHER ROOMS BESIDES KITCHEN, BATHROOMS ,GARAGES, LAUNDRY ROOMS, UTILITY ROOMS, AND CLOSETS SHALL BE EITHER HIGH EFFICACY OR CONTROLLED BY DIMMERS OR VACANCY 5E N5OR5. CA ENERGY CODE 150.0(k)? -ALL OUTDOOR LIGi-ITINS ( MOUNTED 1'O BUILDI'NS ) SHALL BE EITHER HIGH EFFICACY OR CONTROLILED BY MOTION SENSOR IN CONJUNCTION WITH 30-ARIAL VIEW FIRE PROTECT UNDER5IDE OF EAVE5 W/ NDN-GOMBU5TIBLE 51DING OR 5TUCCO 11 REAR ELEVATION � � � � I � I I DUAL GLAZED WNL 1^4IDOW5 /ONE SIDE TEMPERED, U.N.D. V 1/2" VERTIGLE SHEET PLY SIDING PER DETAIL PLN. E 30 YR. COMP 5HINGLE51^11(2 ) LAYERS OF 15 LB. FELT OVER LAPPING AT 19" O.G. 11 I I I I I I I I 1-3/5" SOLID GORE EXT. DOORS W/ 20 MIN. FIRE RATING FRONT ELEVATION PLANS CONFORM TO THE 2013 CALIF. BUILDING CODE ( CSC) ,2013 CALIFORNIA RESIDENTIAL CODE (CRC), 2013 CALIFORNIA MECHANICLE CODE ( CMC ),2013 CALIFORNIA PLUMBING CODE ( CPC ), 2013 CALIFORNIA ELECTRICAL CODE ( CEC ), AND 2013 CALIFORNIA ENERGY CODE ( CEC ) SYMBOLS Y : =WALL LINE = SHEAR WALL SCH. = CROSS SEC. / PG NUM. ® = FOUNDATION WALL/ DETAILS PG = CONST. DETAIL I PG # 2 12 PITCH 14 % FT. IRIOHT 510 Mld'NOSN3ounf ILi unn:rc ncc•r/-nro 'CAD GENERATED HOUSE PLAIDS "3-D VEIWS ' FULL PERMIT SETS " DESIGNED HOW "YOU" LIKE JIM PEPPLER (530) 872-3339 HM/OFF (530) 514-3991 CELL PO BOX 1646 PARADISE CA 95967 SIGNED BY: �Evr�l� s DATE: 4-14-16 CHK. 1 6-29-16 CHK.2 T -18-1b SITE PLAN 1 FLOOR PLAN 2 ELEVATIONS 3 FOUNDATION 4 ROOF PLN 4 SECTION 4 ELECTRICAL 3 STRUCTUAL S4 STRUCTUAL S2 STRUCTUAL S3 (x) ATTIC VENTILATION CALCULATIONS WIDTH IN ( UNDERFLOOR NFVA AREA IN SQ, HOW AREA IN SQ. FLOOR AREA IN SQ, FT. OF NET VENTILATION GROSS AREA OF VENTS SQ. FT. AREA REQUIRED REQUIRED IN SQ. FT. 688 - 150 - 4.58 41 = 144 - 285 x. TYPE OF WIDTH IN HEIGHT IN AREA IN SO, AREA IN SQ. HOW AREA IN SQ. VENT INCHES INCHES IN, OR NFVA FEET EACH MANY FT. PROVIDED RIDGE LIN x FT. - 12 - = 0 x 0 = 0 SAVE 22. x F41 = 144 = 285 x 16 EYEBRUV. x - 72 - 144 = .50 x TOTAL VENT" AREA PROVIDED -MUST EQUAL OR EXCEED GROSS AREA REQUIRED 5.50 VULCAN VENT OR EQUIV. AREA) O'HAGIN ROOF VENT ( ) ATTIC VENTILATION CALCULATIONS (x) UNDERFLOOR FLOOR AREA IN SQ, FT. OF NET VENTILATION GROSS AREA QE VENTS SCS. FT. AREA REQUIRED REQUIRED IN SQ. FT. 512 = 150 = 3.41 = 1 3.41 TYPE OF WIDTH IN HEIGHT IN NFVA AREA IN SQ, HOW AREA IN SQ. VENT INCHES INCHES (SQ. IN.) FEET EACH MANY FT. PROVIDED FOUND. 14 x ®= 41 = 144 - 285 x. 00x0=0-144=0x0=� S9 CTUAL S2 CTUAL E S3 0 0 x 0= 0- 144 - OXO= TOTAL_ VENT AREA PROVIDED-( MUST EQUAL OR EXCEED GROSS AREA REQUIRED) k VULCAN FOUNDATION VENT OR EQUIV. (NFVA:::: NET FREE VENTILATION AREA) x [TO EA. X 22„ '.NT OR TOTAL) - ON 6/53 7lL" LVL (E) ROOF FRAMING 2X BLWO EX15TINO HOU5E RA15ED MOOD FLOOR FRAMING PER. FOUND. PLN. MAL M ,�" 1% 56. 31S It = 1 FT. 1/21, Cox OR 0.5.5. PLY ROOF 5HEATHINCG PONY VgALL 1Nl 2 X 6 AT 16" O.G. 30 YR. COMP SHINOLE5 N1(2 ) LAYERS OF 15 LB FELT OVER. LAPPING AT 1 q" O.G. Imo: -30 IN5. ATTIC, 2 X 6 DF. 5TU05 AT 16„ O.G. ERCT. WALL5 7 dJ R -1q IN5,VgALL5—i- 3/4" T & G PLY FLOOR SHEATHING RAFTER PER PLAN NON-COMBUSTIBLE PLY UNDER EAVES '1116„ NON- COMBUBTIBLE 4` X V VERTIGLE SHEET SIDING VAPOR BARRIER HOUSE kNRAP PROVIDE 20" X 30 " MIN. 15" CLEAR MIN. �_._�-1�i INS. UNDER FLOOELAkWE55 UNDER FLOOR BUTTE COUNTY DEVELOPN ENT SERVICES REVIEWED F DR =1 I I=111=1 I I=1 11=1 11=1 I I=1 III-III-III=1 I I -III -III -I I I -I I I= coDE COMPLIANCE =III=III=) I I=III=III=III=I I = ROUND ADJACENT TO ITHE FOUNDATION MUST -I I I=I I = _ �3Y III=III=III=III= 5LOPE AYgAY FROM BUILDINO AT NOT LE5�=-111I- I=III=III=III= THAN 6" MTH IN THE FIR5T 10 FT. (5% 5LOPE ):III=III=III=III=I N-ld'NOSN39Hnr ' 1r) unanl✓ nJ=efl-_Alc CAD GENERATED HOUSE PLANS ' 3-D VEIWS FULL PERMIT SETS ' DESIGNED NOW "YOU" LIKE JIM PEPPLER (530) 872-3339 HMIOFF (530) 514-3991 CELL PO BOX 1646 PARADISE CA 95967 SIGNED BY: DATE: ft Alm. 00 1� vJ 'U wc� c� 0 cc v iz V) ix z0 3: LL. o I 5 J 'Q Q) 0 U W w Z3 0 U ri c� m 0 A.P. NUM. 0556-270-023 DATE: 4-14-16 CHK. 1 6-29-16 CHK 2 7-18-1b SITE PLAN 9 FLOOR PLAN 2 ELEVATIONS 3 FOUNDATION 4 ROOF PLN 4 SECTION 4 ELECTRICAL 3 STRUCTUAL S9 CTUAL S2 CTUAL E S3 PLANS CONFORM TO THE 2013 CALIF. BUILDING CODE ( CBC) ,2013 CALIFORNIA RESIDENTIAL CODE (CRC), 2013 CALIFORNIA MECHANICLE CODE ( CMC ),2013 CALIFORNIA PLUMBING CODE ( CPC ), 2013 CALIFORNIA ELECTRICAL CODE ( CLQ,_AND AND 2013 CALIFORNIA ENERGY CODE ( CEL) 1 PG. PG DETAIL PLANS SYMBOLS KEY: = WALL LINE A=SHEAR WALL SCH. PG _ CROSS SEC. I PG NUM. ®TITLE = FOUNDATION WALL/ DETAILS PG = CONST. DETAIL! PG # STRUCTURAL NOTES I. GENERAL A. ALL WORK SHALL CONFORM TO THE 2013 GBG AND ALL APPLICABLE LOCAL CODES. B. THE ENGINEER OF RECORD (CHAD RATZLAFF) HAS PROVIDED AND 15 RESPONSIBLE FOR SPECIFIC ITEMS DEPICTED IN THE ATTACHED CALCULATIONS. REQUIREMENT5 NOT 5PEGIFIGALLY SHOWN IN THE ATTACHED CALCULATIONS AND DETAILS ARE THE RESPONSIBILITY OF THE OWNER OR CONTRACTOR. OTHER BUILDING CODE REQUIREMENTS NOT INCLUDED IN THIS DESIGN INCLUDING WATERPROOFING, FIREPROOFING, DRAINAGE, HANDICAP AGCE551BILITY, EGRESS REQUIREMENTS, PARKING, BUILT-UP BUILDING PAD, AND ALL OTHER DESIGN REGtUIREMENT5 NOT 5PEGIFIGALLY 5HOWN IN THE STRUCTURAL DESIGN CALCULATIONS. G. ALL WATERPROOFING AND FLASHING FOR, BUT NOT LIMITED TO, ROOFS, FOUNDATIONS FLOORS, ETC, 15 THE RESPONSIBILITY OF THE CONTRACTOR OR OWNER. D. SHOULD ANY CHANGES BE MADE FROM THE DESIGN AS SPECIFIED IN THESE DOCUMENTS WITHOUT THE WRITTEN APPROVAL FROM THE ENGINEER, THEN THE ENGINEER WILL ASSUME NO RESPONSIBILITY FOR ANY ELEMENT OR SYSTEM OF THE STRUCTURE. E. THE CONTRACTOR 15 RESPONSIBLE FOR THE METHOD OF CONSTRUCTION AND SHALL PROVIDE ALL SAFETY MEASURES NECESSARY TO PROTECT THE PUBLIC, CON5TRUGTION WORKERS AND THE STRUCTURE DURING CONSTRUCTION. TH15 SHALL BE ACCOMPLISHED BY SHORING, FORMING, BRACING, SCAFFOLDING. F. 51MILAR CONDITIONS SHOWN IN THE DRAWINGS SHALL BE USED IF ANY PART OF THE CONSTRUCTION 15 NOT FULL DEPICTED IN THESE DRAWIN65 OR CALCULATIONS. G. CONTRACTOR SHALL FIELD VERIFY ANY CONDITION NOTED AS EXISTING ON THE PLANS. ANY DI5GREPANCIE5 SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER of RECORD AND 5HALL BE FULLY REVIEWED BEFORE PROCEEDING WITH CONSTRUCTION. H. STRUCTURAL DRAWING5 AND DETAILS SUPERCEDE ANY SHOP DRAWINGS IN ALL CIRCUMSTANCES. THE CONTRACTOR SHALL VERIFY THAT ALL CONSTRUCTION 15 IN FULL AGREEMENT WITH THE LATEST STRUCTURAL DRAWIN65 AND DETAILS. THE REVIEW OF THE SHOP DRAWINGS BY THE ENGINEER OF RECORD 15 FOR GENERAL CONFORMANCE WITH THE STRUCTURAL DESIGN INCLUDING LOADING AND DIMENSIONS. THE REVIEW DOES NOT GUARANTEE THAT THE SHOP DRAWINGS CORRECT. I. WALL FINI5HE5 SUCH A5 5TUCCO OR PLASTER SHALL BE APPLIED OVER A SYSTEM TO ADEQUATELY ALLOW THE FIN 1 SH TO EXPAND AND OR CONTRACT WITHOUT CRACKING. I T SHALL BE THE RE5PON51 B I L I TY OF THE OWNER OR CONTRACTOR TO INSURE THAT DEFECTS IN THE FINISHES DO NOT HAPPEN. J. STRUCTURAL DRAWIN65 OR DETAILS SHALL NOT BE SCALED. K. FULL-TIME OR PARTIAL SPECIAL INSPECTION OF THE PROJECT SHALL BE CONDUCTED IN ACCORDANCE WITH GBG 2013 SECTION 108. THE FOLLOWING TYPES OF CONSTRUCTION SHALL BE INSPECTED: - NO SPECIAL INSPECTION REQUIRED FOR THIS PROJECT. THE SPECIAL INSPECTOR SHALL BE ACCEPTABLE TO THE ENGINEER OF RECORD AND BUILDING DEPARTMENT AND SHALL BE IGBO QUALIFIED, AND THEIR EXPERIENCE SHALL BE COMMENSURATE WITH THIS TYPE OF INSPECTION REQUIRED. 2. DESIGN REQUIREMENTS: A. THE 5TRUGTURE HAS BEEN DESIGNED FOR THE FOLLOWING CRITERIA PER GBG 2015 CHAPTER 16, DIVISIONS 1, 11, 111, AND IV U.N.D.: B. SEISMIC: SEISMIC IMPORTANCE FACTOR: I SEISMIC SITE GLASS: D SEISMIC DESIGN CATEGORY: D RESPONSE MODIFICATION FACTOR: R = 6.5 MAPPED SPECTRAL RESPONSE ACCELERATIONS: Ss = 0.156, 51 = 0.321 SPECTRAL RESPONSE COEFFICIENTS: 5D5 = 0.603, SDI = 0.381, Gs = 0.0943 BASIC SEISMIC -FORGE -RESISTING SYSTEM: LIGHT FRAMED SHEAR WALLS SEISMIC, BASE SHEAR: 5.15 KIPS (ULTIMATE) ANALY515 PROCEDURE USED: EQUIVALENT STATIC FORGE PROCEDURE G. WIND: WIND SPEED: 110 MPH WIND EXPOSURE: G D. GRAVITY LOADS: LIVE LOADS: ROOF.............................................. 20 PSF FLOOR............................................. 40 PSF SLEEPING ..................................... 30 PSF ROOF SNOW .................................. 9'7 PSF 3. SITE WORK AND FOUNDATIONS: A. ASSUMED MAXIMUM SOIL BEARING = 1500 P5F PER GBG TABLE 1806.2. UNLE55 OTHERWISE NOTED BY GEOTECHNICAL REPORT. B. BUILDING SITE 15 ASSUMED TO BE DRAINED AND FREE OF CLAY OR EXPANSIVE SOIL. ENGINEER HAS NOT MADE A GEOTECHNICAL REVIEW OF SITE, ANY OTHER CONDITIONS ENCOUNTERED MUST BE BROUGHT TO THE ATTENTION OF THE ENGINEER. G. ALL FOOTINGS (RETAINING WALL, SPREAD AND WALL FOOTINGS) SHALL BE CONSTRUCTED WITH A DEPTH BELOW THE FROST LINE, 12" MIN AND PER LOCAL REQUIREMENTS. D. ALL FOUNDATION TRENCHES SHALL BE GLEAN, FREE OF DEBRIS AND LEVEL. E. NATIVE OR FINISHED GRADE SHALL SLOPE AWAY FROM THE STRUCTURE A MINIIMUM SLOPE OF 5% FOR A MINIMUM 10 FEET HORIZONTAL. FIN15HED SURFACES SUCH AS CONCRETE OR ASPHALT SHALL SLOPE A MINIMUM 2% OR PER ADA REQUIREMENTS. F. IF BUILDING PAD 15 REQUIRED, FILL MATERIAL SHALL BE FREE FROM DEBRIS, VEGETATION AND OTHER FOREIGN MATERIALS. ENGINEERED FILL SHALL BE DESIGNED, INSPECTED AND CERTIFIED BY A THIRD PARTY OTHER THAN THE ENGINEER OF RECORD. G. RETAINING WALL5 SHALL BE GON5TRUGTED WITH A MINIMUM 4" DIAMETER DRAIN PLACED AT THE BASE OF THE RETAINED SIDE OF THE WALL. PIPE SHALL BE SLOPED AND DRAINED TO DAYLIGHT. H. A GEOTHECHNICAL ENGINEER MUST APPROVE THE PLACEMENT OF FOUNDATIONS ON OR ADJACENT TO SLOPES. ENGINEER OF RECORD SHALL NOT BE LIABLE FOR ANY FOUNDATIONS NOT DESIGNED IN ACCORDANCE WITH CHAPTER 15 SECTION 1805 OF GBG 2013. I. THIS DESIGN AND CALCULATIONS A55UME UNDISTURBED SOILS AND STABLE, LEVEL, OR STEPPED FOOTINGS. IT SHOULD BE BROUGHT TO THE ATTENTION OF THE ENGINEER OF RECORD PRIOR TO CONSTRUCTION IF OTHER CONDITIONS ARE PRESENT. J. NO RECOMMENDATIONS HAVE BEEN MADE FOR CONDITIONS WHERE THE LOADS TO THE EXISTING FOUNDATIONS HAVE NOT BEEN SIGNIFICANTLY INCREASED. ONLY LOCATIONS WHERE LOADS HAVE BEEN INCREASED SIGNIFICANTLY HAVE BEEN ADDRE55ED IN TH15 DE516N. THE OWNER SHALL BE ADVISED THAT THE EXISTING FOUNDATIONS MAY OR MAY NOT BE 5TRUGTURALLY ADEQUATE. sETTLEMENT, CRACKING AND OTHER PROBLEMS ASSOCIATED WITH EXISTING FOUNDATIONS ARE BEYOND THE SCOPE OF THIS DESIGN. 4. CONCRETE: A. CONCRETE SHALL HAVE A MINIMUM 28 DAY STRENGTH OF 2,500 1=51 U.N.O. B. ALL GEMENT USED SHALL CONFORM TO ASTM 0-150 AND SHALL BE TYPE 11 OR TYPE III LOW ALKALI. G. AGGREGATE SHALL CONFORM TO ASTM G-33 AND SHALL NOT CONTAIN MATERIALS WHICH ARE ALKALI REACTIVE AS DETERMINED BY ASTM G-22'7, 2894, AND 215. IF TEST DATA 15 UNAVAILABLE IN REGARDS TO ALKALI REACTIVE MATERIALS, PROVIDE GEMENT WITH A MAXIMUM ALKALI CONTENT LESS THAN 0.45% BY WEIGHT. D. CONCRETE EXF05ED TD FREEZING OR THAWING SHALL BE PROTECTED IN ACCORDANCE TO THE LATEST EDITION OF THF AGI 518. E. SLABS ON GRADE SHALL BE PER THE CONTRACTOR. THE FOLLOWING SHALL BE USED A5 A MINIMUM: -AT GARAGE SLABS; USE 4" THICK S.O.G. WITH #5 BARS AT 15" O.G. EACH WAY ABOVE MID -DEPTH OF SLAB OVER M015TURE BARRIER OVER 4" AGGREGATE BASE. -AT ALL OTHER CONDITIONS; USE 3-1/2" SLAB WITH #3 AT 15" E.W. ABOVE MID -DEPTH OF SLAB, OR 6X6 WWF ABOVE MID -DEPTH OF SLAB WITH SAME SUB -SLAB BUILDUP AT ALL OTHER AREAS. F. 5AW-GUT SLAB WITH 3/4" DEEP GROOVE FOR CRACK CONTROL AT INTERVALS NOT TO EXCEED 15'-0" 3 IS REINFORCED, INTERVALS SHALL NOT TO EXCEED 8'-0" WHERE SLAB 15 UN -REINFORCED. 5. REINFORCING STEEL A. ALL REINFORCING STEEL SHALL BE ASTM A615, GRADE 40 FOR #4 BARS AND SMALLER. ALL REINFORCING STEEL SHALL BE ASTM A615, GRADE 60 FOR #5 BARS AND LARGER. WELDED WIRE FABRIC, 15 TO BE ASTM AI85 WITH LAPPING OF 1 1/2 SPACES. B. ALL BARS SHALL BE DEFORMED PER A5TM A505. G. ALL BARS SHALL BE GLEAN AND FREE OF LOO5E FLAKY RU5T, GREASE OR OTHER BOND IMPAIRING MATERIALS. D. ALL BENDS SHALL BE MADE GOLD. E. LAP REINFORCING 40 BAR DIAMETERS, U.N.D. F. REINFORCEMENT COVER SHALL BE A5 FOLLOWS: -CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO SOIL: 5" -CONCRETE WITH SOIL OR WEATHER EXPOSURE: #5 BARS AND SMALLER - 1 1/2" #6 BARS AND LARGER 2" -CONCRETE WITHOUT 501L OR WEATHER EXPOSURE: 3/4" G. ALL REINFORCING STEEL AND ANCHOR BOLTS SHALL BE ACCURATELY LOCATED AND ADEQUATELY SECURED IN POSITION BEFORE AND DURING CONCRETE PLACEMENT. 6. FRAMING LUMBER: A. MINIMUM NAILING SHALL BE PER GBG 2015 TABLE 2304.94.1, U.N.O. B. ALL FRAMING MEMBERS SPECIFIED IN THESE CALCULATIONS ARE MINIMUMS, LARGER MEMBERS OF SAME SPECIES MAY BE SUBSTITUTED AT CONTRACTORS OPTION. G. CARE SHALL BE TAKEN TO ALLOW FOR EFFECTS OF 5HRINKAGE WHICH COULD CAU5E SETTLEMENT OF ROOF AND OR FLOORS AND COULD LEAD TO FAILURE OF A550CIATED FRAMING MEMBERS OR COMPROMISED WATERPROOFING SYSTEM. THE CONTRACTOR SHALL TAKE ALL MEASURES NECESSARY TO PROTECT FRAMING FROM THE EFFECTS OF SHRINKAGE. D. ALL STRUCTURAL FRAMING MEMBER WITH EXTERIOR EXPOSURE SHALL BE PRESSURE 7REATED OR BE OF MATERIAL THAT 15 NATURALLY RESISTANCE TO DECAY. 6.1 MATERIALS: A. SHEATHING: -ROOF SHEATHING: SEE ROOF FRAMING PLAN5 -FLOOR SHEATHING: SEE FLUOR FRAMING PLANS -WALL SHEATHING: SEE SHEAR WALL SCHEDULE B. GLUE -LAM BEAMS SHALL BE 24F -V4 U.N.O. WITH A CAMBER OF R=1600' U.N.O. GLUE -LAMS EXPOSED TO WEATHER MUST BE RATED FOR EXTERIOR USE BY THE MANUFACTURER. G. GLUED LAMINATED FABRICATION SHALL BE PERFORMED IN AN APPROVED FABRICATORS SHOP IN ACCORDANCE WITH GBG 2303.1.3, AITG A110.1, AND ASTM D 3"13'7. BEAM INSPECTION CERTIFICATES SHALL BE SUBMITTED TO THE FIELD INSPECTOR PRIOR TO COMPLETION OF FRAME INSPECTION IN ACCORDANCE WITH GBG 1'704.2. D. MICRO -LAM BEAMS, LVL (LAMINATED VENEER LUMBER) SHALL HAVE FB = 2800 PSI 4 FV= 285 PSI MIN., AND SHALL BE MANUFACTURED, APPROVED AND IDENTIFIED AS PER NER-481 E. SILL PLATES SHALL BE PRESSURE TREATED DOUGLAS FIR WITH ANCHOR BOLTS PER SHEAR WALL SCHEDULE AND 3" X 5" X.229" PLATE WASHERS LOCATED AT 6'-0" O.G. MAX. WITH ONE BOLT LOCATED 1'-0" MAXIMUM FROM EACH END OF EACH PIECE. F. ALL FRAMING LUMBER SHALL BE DOUGLAS FIR LARCH AS GRADED BY THE W.W.P.A. OR W.G.L.I.B. AND SHALL HAVE A MOISTURE CONTENT LESS THAN 1955, U.N.O. -STUDS SHALL BE STUD GRADE OR BETTER. -ALL POSTS SHALL BE DF -L #1 U.N.O. -2X AND 5X RAFTERS SHALL BE DF -L #2 U.N.O. -2X JOISTS SHALL BE DF -L #2 U.N.O. -CONGEALED BEAMS SHALL BE DF -L #2 -EXPOSED BEAMS SHALL BE DF -L #1 APPEARANCE GRADE FOHG (4X6 AND LARGER) -ALL BEAMS 6X AND LARGER SHALL BE FREE OF HEART CENTER. G. ALL NAILS SHALL BE COMMON U.N.O. WHERE EXPOSED TO WEATHER OR WITHIN IS" OF FOUNDATION, NAILS SHALL BE GALVANIZED. WHERE DRIVEN INTO PRESSURE TREATED MATERIAL, NAILS SHALL BE HOT DIPPED GALVANIZED. H. BOLTS AND LAG 5CREW5 SHALL BE A5TM A-301 U.N.O. AND PROVIDED NEW AND WITHOUT EXGE551VE RUST. 1. ALL HARDWARE GALLED SHALL BE SIMP50N STRONG TIE CO., OR ENGINEER APPROVED EQUIVALENT, INSTALLED PER MANUFACTURER'S RECOMMENDATIONS WITH ALL HOLES FILLED WITH RECOMMENDED FASTENERS. ALL CONNECTORS IN CONTACT WITH PRESSURE TREATED MATERIAL SHALL BE, HOT DIPPED GALVANIZED, ZMAX, STAINLESS STEEL OR AS OTHERWI5E DIRECTED BY MANUFACTURER FOR CORROSION RE515TANGE AGAIN5T SPECIFIC PRESSURE TREATMENT CHEMICAL. J. MANUFACTURED I JOISTS (SUCH A5 TRU55 JOISTS, OR BCI) SHALL BE INSTALLED PER THE MANUFACTURES RECOMMENDATIONS U51NG A DEFLECTION LIMIT OF L/480 U.N.O. USE A MANUFACTURED 1-1/4" RIM BOARD (SUCH AS TIMBER STRAND) WITH ALL "I" JOISTS. USE A DOUBLE RIM OR 1-3/4" LVL RIM AT ALL LOCATIONS WHERE LEDGERS ARE USED, SUCH AS DECK LEDGERS. 6.2 BEAMS AND POST51 A. ALL BUILT UP MULTIPLE 2X J015T5 AND BEAMS SHALL BE NAILED TOGETHER WITH 16d NAILS AT 6" O.G., T4 B U.N.O. B. BUILT UP MULTIPLY LVL BEAMS SHALL BE FASTENED TOGETHER PER MANUFACTURES REGOMMENDATIONS. G. PROVIDE DOUBLE FLOOR JOISTS UNDER PARTITION WALLS RUNNING PARALLEL TO JOIST SPAN AND UNDER ALL LOCATIONS WHERE TUBS MAY BE LOCATED. ADEQUATE SUPPORT SHALL BE PROVIDED FOR ALL OTHER EQUIPMENT OR FURNISHINGS WHICH MAY NOT BE SHOWN ON THE STRUCTURAL DRAWINGS INCLUDING BUT NOT LIMITED TO: HOT WATER HEATER, STOVE, REFRIGERATOR, OVEN, FIRE PLACE ENC1_05URE5, WOOD BURNING STOVE, ETC.. . D. PROVIDE SOLID BLOCKING IN JOIST FRAMING ABOVE ALL SUPPORTS E. SUPPORT ALL UPPER LEVEL POSTS AND TRIMMERS IN LONER LEVELS WITH EQUIVALENT FRAMING AND BLOCK OR OTHERWISE FRAME P05T5 THROUGH FLOOR SYSTEMS. F. VERTICAL GRAIN BLOCKING OR FRAMING SHALL BE USED WHERE POSTS WITH COLUMN GAPS OR BEARING PLATES ARE 5PEG I F I ED 6.3 WALL FRAMING: A. TOP PLATE SPLICES OF STUD WALLS SHALL BE 48" LONG WITH (12) 16d SINKERS EACH SIDE OF EACH SPLICE U.N.O. WHERE SPLICE 15 INTERRUPTED OR PLATE IS DISCONTINUOUS, USE ST2122 STRAP U.N.O. B. DOUBLE TOP PLATE SPLICES AND JOINTS IN DOUBLE TDP PLATE OF LOAD BEARING WALLS SHALL OCCUR AT THE CENTER LINE OF SUPPORTING STUD. G. FIRE BLOCK STUD WALLS AT MID -HEIGHT WHERE STUD LENGTH EXCEEDS ID' -D" D. WHERE SHEAR ANCHOR BOLTS HAVE BEEN INCORRECTLY PLACED, USE 51MP50N TITEN HD ANCHORS WITH 6" MINIMUM EMBEDMENT INTO CONCRETE AND INSTALLATION PER MANUFACTURERS RECOMMENDATIONS AND CURRENT 10150 REPORT. E. CRIPPLE WALLS SHALL BE A MINIMUM OF 14" IN HEIGHT. FOR LESSER HEIGHTS, STACK 2X PLATES. F. NOTCHED AND/OR GUT STUDS TO FIT AROUND ANCHOR BOLTS ARE NOT ALLOWED. STUDS SHALL HAVE FULL BEARING TO THE FOUNDATION PLATE. G. LET IN BRACES SHALL NOT BE USED FOR TEMPORARY BRACING ON ANY WALL FRAME. STEEL STRAPS WHICH DO NOT REQUIRE THE GUTTING OF 5TUD5 ARE AN ACCEPTABLE ALTERNATIVE. H. SEE NOTE 6.1-E FOR SILL AND ANCHOR BOLT SPECIFICATIONS. I. WALL FRAN,ING RECEIVING NAILING AT 5" ON CENTER OR LESS SHALL BE 3X NOMINAL U.N.O. PER PLANS AND SHEAR WALL SCHEDULE. 6.4 CONNECTIONS: A. HOLES FOR THROUGH BOLTS SHALL BE DRILLED 1/16" OVERSIZE. B. ALL BOLTS, NUTS, AND LAG 50REW5 SHALL BE PROVIDED WITH FLAT OR MALLEABLE WA5HERS WHERE BEARING AGAINST WOOD. G. ALL BOLTS AND LAG SCREWS SHALL BE TIGHTENED UPON INSTALLATION AND RE -TIGHTENED BEFORE CLOSING IN OR AT COMPLETION .OF JOB. D. LAG SCREWS SHALL BE SCREWED, NOT DRIVEN, INTO PLACE. 8.2 OUT AND 5TAGKED ROOF FRAMING: A. OUT AND 5TAGKED ROOF SYSTEMS SHALL BE BUILT TO THE CONVENTIONAL FRAMING REQUIREMENTS OF THE LATEST CALIFORNIA BUILDING CODE (CHAPTER 23). PURL I N5, BRACES, I NTERMED I ATE SUPPORTS, AND CONNECTiON5 SHALL BE PROVIDED BY THE CONTRACTOR THAT ARE CAPABLE OF TRANSMITTING ALL GRAVITY AND WIND LOADS TO THE FOUNDATION. THE FOLLOWING ADDITIONAL LIMITATIONS SHALL APPLY: I. RAFTER MAXIMUM 5PAN5 A. 2X6 DF -L #2: -1'-0" B. 2X8 DF -L #2: q' -O" G. 2X10 DF -L #2: 11'-0" 2. MINIMUM BRACE SIZE = 2X6 3. MAXIMUM BRACE SPACING = 4'-0" O.G. 4. PURLIN 51ZE SHALL MATCH THE SUPPORTED RAFTER SIZE U.N.O. B. IT 15 THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE THE CONVENTIONALLY FRAMED ROOF SYSTEM WITH TIES AND SUPPORTS BRACING ALL ELEMENTS TO THE FOUNDATION. THE ENGINEER HAS MADE A CURSORY REVIEW OF THE FRAMING SIZES AND SUPPORT LOGATION5, AND HAS PROVIDED GENERAL CONNECTION DETAILS TO COVER THE MAJORITY OF CONDITIONS, BUT HAS NOT PROVIDED ENGINEERING DETAIL REQUIREMENTS FOR ALL CONNECTIONS NECESSARY FOR THE ROOF TO PERFORM IN ACCORDANCE WITH THE LOADING CRITERIA. IF ANY SPECIFIC ELEMENT OF THE ROOF FRAMING SYSTEM 15 NOT 5HOWN AND DETAILED CONNECTION CRITERIA 15 REQUIRED, PLEASE CONTACT THE ENGINEER FOR ADDITIONAL INFORMATION. ABBREVIA77ONS AB ANCHOR BOLT L AN&LE ADD'L ADDITIONAL LLH LONG LEG HORIZ. ADJ ADJACENT LLV LONG LEG VERT. ALT ALTERNATE LONG LONGITUDINAL ANG ANCHOR LSL LONG SLOTTED HOLE ARCH ARCHITECTURAL LVL LAMINATED VENEER LUMBER BLDG BUILDING MAX MAXIMUM BLKG BLOCKING MB MACHINE BOLTS BM BEAM MEGH MECHANICAL BOT (B) BOTTOM MFR MANUFACTURER BTWN BETWEEN MIN MINIMUM 0 MISC. MISCELLANEOUS GB CARRIAGE BOLTS MTL METAL CCJ CONTROL JOINT a GIP CAST -IN-PLACE CONCRETE (N) NEW GJ CONSTRUCTION JOINT NOM NOMINAL CLR CLEAR NS NEAR SIDE GMU CONCRETE MASONRY UNITS NSA NELSON STUD ANCHOR COL COLUMN NTS NOT TO SCALE GONG CONCRETE CONN CONNECTION OG ON CENTER GONSTR CONSTRUCTION OD OUTSIDE DIAMETER CONT CONTINUOUS OH OPPOSITE HAND CONTR CONTRACTOR OPNG OPENING GP COMPLETE PENETRATION OVS OVERSIZE ROUND HOLE GTR CENTER �o CT5K COUNTERSINK PDF POWDER DRIVEN FASTENER In o PERP PERPENDICULAR DBA DEFORMED BAR ANCHOR PL PLATE DBL DOUBLE PLYWD PLYWOOD DF -L DOUGLA5 FIR - LARCH PL05 PLACES DIA DIAMETER PP PARTIAL PENETRATION DJ DOUBLE JOIST PT PRESSURE TREATED DO DITTO P/C' PRECAST CONCRETE DWL DOWEL P/T POST -TENSIONED EA EACH REINF REINFORCEMENT EF EACH FACE REOV REQUIRED El. ELEVATION (DATUM) ELEV ELEVATION 5C SLIP CRITICAL EN EDGE NAILING SHG SHEATHING EQ EQUAL SIM SIMILAR ES EACH SIDE SOC, SLAB -ON -GRADE EXIST (E) EXISTING SSL SHORT SLOTTED HOLES EXP EXPANSION 5TO STANDARD EXT EXTERIOR STIFF STIFFENER EW EACH WAY 5TL STEEL so SQUARE FF FIN15H FLOOR 51rM SYMMETRICAL FIN FINISH C FJ FLOOR JOIST T 4 B TOP 4 BOTTOM FLR FLOOR T O (P) TOP OF (PLYWOOD) FNDN FOUNDATION TOG TOP -OF -CONCRETE FOS FACE OF STUD TOF TOP -OF -FOOTING F5 FAR SIDE TOS TOP -OF -STEEL FTG FOOTING TOW TOP -OF -WALL TN TOE NAIL GA GAGE TYP TYPICAL GALV GALVANIZED. GLB GLUE -LAM BEAM UNO UNLE55 NOTED OTHERWISE HDR HEADER VERT (V) VERTICAL HGR HANGER (SIMPSON) HORIZ (H HORIZONTAL WP WORKPOINT 145B HIGH STRENGTH 130LT5 WWF WELDED WIRE FABRIC, ID INSIDE DIAMETER W/ WITH INT INTERIOR W/O WITHOUT J5T JOIST JT JOINT PER `,IT # BUTTE COUNTY DEVELOPMENT SERVICES K KIPS REVIEWED FOR DATE REV DATE BY 1 06.29.16 CMR 2 07.18.16 CMR J a H W LAi 0 z J a V c 0 L.L. z 0 CZ �o a In o Z a 0 Lu 0 Lu LAI �>. OZ Lu O u.l L.L. � N Q Ln .Q W ~ ® ctn INA e' u 00 - Ln W Ln Lu ' Ln yFESSI M• 0643 �t .6 sr Cl q �OF C JULY 18, 2016 Phase: PERMIT Ckd. Bye CMR Date: 04.12.16 Project #: 16-010 DRAWING NUMBER 0 16" O.G. MAX 5PAGIN6 ROUGH 1"'I I OPENING my � G G IN D1 DBL TOP PLATE T45, TYP % PER 4/52 ROU6H OPENING G 0 4" -1/8" 6" 15/51, 8" 115/161, 10" 25/161, 12" 2 13/16" NOTES: I. NOTCHING SHALL NOT OCCUR WITHOUT WRITTEN CONSENT FROM ENGINEER OF RECORD. 2. MAX BORED HOLE DIAMETER UNLESS SPEC I FICA �_LY NOTED OTHERWISE = D/4. �-- P.T. SILL AND 3. HOLES SHALL NOT BE SPACED LE55 THAN "D" INCHES, CENTER TO CENTER. A.B. PCR 8/52 A. HEADER PER PLAN +7/ ('7_� 7WIQ L, JOIST PENET RATION B. TRIMMER PER SCHEDULENOSCALB G. KING STUD PER SCHEDULE SZ D. (2) A35 AT MULTILE KING STUDS E. BLOCK AT PLYWOOD SPLICE, AND MAX 10' UNBRACED STUD LENGTH F. BLOCK SOLID AT MULTIPLE STUDS AND CONTINUE MULTIPLE STUD GROUP TO ( CORNER WHERE OCCURS FOUNDATION. G. NAIL MULTIPLE TRIMMERS/KING STUDS TOGETHER WITH Ibd AT 12" O.G. STAGGERED, U.N.O. H. WALL STUD PER PLAN, DF#2 AT I6" O.G. U.N.O. I. POST PER PLAN 2X4 WALL OPENING SCHEDULE 9PLA7 OPENING SIZE (A) HEADER SIZE T1R;MMERS KING STUDS UP TO 4'-0" SEE PLAN (1) 2X4 (1) 2X4 4'-0" TO 6'-0" SEE PLAN (1) 2X4 (2) 2X4 6'-0" TO 8'-O" SEE PLAN (2) 2X4 (2) 2X4 8'-0" TO 10'-0" SEE PLAN (2) 2X4 (3) 2X4 UP TO 16'-O" SEE PLAN (3) 2x4 (3) 2x4 2X6 WALL OPENING SCHEDULE !OPIATE OPENING SIZE (A) HEADER SIZE TRIMMERS KING STUDS UP TO 6'-0" SEE PLAN (1) 2X6 (1) 2X6 6'-O" TO 8'-O" SEE PLAN (2) 2X6 (1) 2X6 8'-0" TO 10'-0" SEE PLAN (2) 2X6 (2) 2X6 UP TO I6'-0" SEE PLAN (2) 2X6 (2) 2X6 11 TICAL WOOD STUD WALL ELEVAT ION S2 NO SCALE COMPRES51ON POST PER HO SGHED HOLOOWN PER PLAN THREADED ROD EXTENSION SIMP50N o P.T.D.F. SILL PER 5/52 CNA (1) #4 WITHIN SHEAR GONE OF HD A.B. Q z N z ILI Q — DIMENSION "B" -- FOOTING PIAN KEW ryN.:_ " �..° CONT. FND d:, WHERE e OCCURS d � d 55T13 A.B. PER PLAN OR HD 4 a SGHED. 2/5D2 (5) Ibd NAILS AT CORNER OR INT. WALL - Ibd SINKERS AT 4'-0" MIN. LAP LENGTH, TYP I6" O.G. (12) MIN. Ibd SINKERS AT 16" O.G. BETWEEN SPLICES (12) MIN. BETWEEN SPLICES Ibd SINKERS AT 16" O.G. (12) MIN. BETWEEN 5PLICE5 '----STUD AT EA SPLICE \---DBL TOP PLATE CORNER OR INT. WALL WHERE OCCURS TYPICAL TOP PLATE SPLICE DBL TOP PLATE PER ST2122 STRAP, U.N.O. DETAIL ABOVE2 CENTERED ON CONT. WALL DISGONTINUITY � ViHERE OCCURS STUD AT EA SPLICE-' TYPICAL TOP PLATE DISCON'M Un Y SHEAT? NALL 5GHEDULE SHEAR WALL TYPE EDGE NAILIN6 SHEA- THING ALLOW. LOAD #/FT SOLE PLATE FASTENING "SIMPSON" CLIP SPAGIN6 1/2" DIA. AB. -7" EMBED 2X PT SILL SX PT SILL A.B. SPAGIN6 A.B. SPAGIN6 ADD'L NOTES 6 bA" 3/8" 164 12d AT II" O.G. A55 AT 4'-O" O.G, 61-00 0.0. b' -O" O.G. F2 164 Ab b" 3/8" BOT 12d AT '1" O.G. ASS AT 2'-8" O.G. 5'-q" O.G. 4'-3" O.G. (4) #4 EA WAY 260 4* A 4" 3/8" 3'-0" AT 5" O.G. ASS AT 2'-0" O.G. 2'-q" O.G. 51-5110.0. 4 350 !2d (5) #4 EA WAY 4" 3/8" 1511 12d AT 5 O.G. A35 AT 1-10" O.G. 1'-3" O.G. 51-000.0. 4 532 4'-6" 3" 3/8" TOP AND BOT 12d AT 4 O.G. A55 AT I'-5" O.G. 1'-O" O.G. 2'-4" O.G. 4 685 A2" IS" 5/8" 5'-6" Ibd AT 4" O.G. A55 AT I' -I" O.G. N/6 I' -q" O.G. 4 6'-0" 02) #4 EA WAY 4"3/8"Ibd 2 SIDES IE AT 3" O.G. A55 AT II" O.G. N/6 1'-b"O.G. 4 33 AS 3" 2 SIDES 2 SIDES 3/611 1460 16d AT 2" O.G. ASS AT q" O.G. N/6 1'-2" D.G. 4 3 O 22 2"1280 2 5117E5 3/8" PER PLAN 12d AT 2" O.G. A35 AT 'i" O.G. N/6 O'-10" O.G. 4 1760 (5) 16d NAILS NOTES: I. FRAMING: USE 2" NOMINAL OR WIDER DOUGLAS FIR LARCH, PT OF FNDN SILL, STUDS AT Ib" O.G. MAX, + BLOGK ALL PANEL EDGES. + 2. SHEATHING: USE APA RATED (32/16 SPAN RATING) SHEATHING U.N.O, APPLY SHEATHING AND NAILING TO BOTH SIDES OF WALL WHERE SPECIFIED 112 SIDES". + S. NAILS: USE 6d COMMON OR 8d GUN NAILS (DIA. = 0.131") EDGE NAIL AT ALL PANEL EDGES, TOP PLATE, SOLE PLATE, MUD SILL, POSTS, AND HOLD-DOWN COMP. STUDS, FIELD NAIL AT 12" O.G. 12d SINKER _PARTIAL NdWAT TOP SHANK DIA.=0.135", 20d COMMON SHANK DIA.=0.171", DO NOT OVERDRIVE NAILS. STA66ER SOLE FA5TENIN6 AND PRE -DRILL PILOT HOLES (MAX '75% NAIL DIA) TO AVOID SPLITTING WALL ELEMENTS. PLAN CORNER AND TEE SEE DETAIL 3/52 FOR MORE INFORMATION. 4. USE 3X NOMINAL FRAMING AT ABUTTING PANEL ED6ES AND STAGGER NAILING. 4 TYPICAL TOP PLATE SPICE DETAIL1 TYPICAL SHEAR WALL SCHEDULE S2 NO SCAZ.E NOTES: I. SILL PLATE SHALL BE 2X PTDF UNLE55 OTHERWI5E NOTED BY SHEAR WALL SCHEDULE. 2. PROVIDE (2) BOLTS MIN PER SILL PLATE. 3. DIAGONALLY 5LOTTE0 PLATE WASHERS WITH A MAXIMUM SLOT LENGTH OF 1 3/4" MAY BE USED WHEN A STANDARD OUT WASHER 15 ADDED BETWEEN THE PLATE WASHER AND NUT. 4. AT EXISTING FOUNDATIONS OR M155ED A.1525 PROVIDE 1/2" DIAM. TITEN HO AT REQUIRED A.B. SPACING WITH 4" EMBED IN FOUNDATION, 1 3/4" MIN. EDGE DIST., 8" MIN. END DIST., 8" MIN. SPACING. LOCATE AND AVOID ALL REINFORCING PRIOR TO DRILLING. INSTALL PER MFR'S RECOMMENDATIONS 5. ANCHOR BOLT EMBEDMENT SHALL BE DETERMINED BY P.T. SLAB ON GRADE DESIGNER A.B. PER SHEAR WALL SGHED. IN/ 2" HOOK AND 3" X 3" X 0.229" PLATE WASHER, TYP. 5" MIN U.N.O. BY SHEAR WALL 50HED. 6'-O" MAX AT (1) AND (2) STORY FTVr 12 MAX 4'-O" MAX AT (3) STORY AND ABOVE SILL II II II II g TYPICAL HOLDOW N DETAIL 5 S2 1,00 SCALE QS2 z :LR INFORGING PER SCHED. THIGKNE55 3" GLR A FOOTING SECTION 9 SPS FOOTING SCHEDULE S2 NOSCALE AT RETROFIT OR FOUNDATION MISPLACED A.B. B.O. PER PLAN SEE NOTE 4 VCHOR BOLT SPACING DETAIL WALL FRAMING WALL FRAMING PER PLAN PER PLAN NO SCALE NO SCALE HOLDONN 50HEDULE SIMPSON MODEL NUMBER FOOTING SCHEDULE DIST. FROM CENTER OF GONG. ANCH. TO FACE OF P05T ANCHOR TYPE, U.N.O. PER PLAN, SEE NOTE 2, 3 I OR 2 1 2 POUR POUR POUR FOOTING TYPE THICKNESS, U.N.O. DIMEN51ON A DIMENSION B REINFORCING LOCATION F1.5 12" 1'-6" 1'-6" (2) #4 EA WAY BOT F2 12" 2'-0" 2'-0" (3) #4 EA WAY BOT F2.5 12" 2'-6" 2'-6" (4) #4 EA WAY E30T F3 12" 3'-0" 3'-0" (4) #4 EA WAY BOT F3.5 12" 31-6" 3'-6" (5) #4 EA WAY BBOT F4 1511 4'-0" 4'-0" (6) #4 EA WAY TOP AND BOT F4.5 18" 4'-6" 4'-6" (6) #4 EA WAY TOP AND BOT F5 18" 5'-0" 5'-0" (10) #4 EA WAY TOP AIND BOT F5.5 IS" 5'-6" 5'-6" (II) #4 EA WAY TOP AND BOT F(b IS" 6'-D" 6'-0" 02) #4 EA WAY TOP AIND BOT 9 SPS FOOTING SCHEDULE S2 NOSCALE AT RETROFIT OR FOUNDATION MISPLACED A.B. B.O. PER PLAN SEE NOTE 4 VCHOR BOLT SPACING DETAIL WALL FRAMING WALL FRAMING PER PLAN PER PLAN NO SCALE NO SCALE HOLDONN 50HEDULE SIMPSON MODEL NUMBER MIN. COMP. POST DIST. FROM CENTER OF GONG. ANCH. TO FACE OF P05T ANCHOR TYPE, U.N.O. PER PLAN, SEE NOTE 2, 3 I OR 2 1 2 POUR POUR POUR NAILS/ MIN. 5D5 STEM 5CREW5/ WALL POST BOLTS WIDTH HDU2 DBL 2X 15/161, 5B 5/8x24 SSTBI6 SST520 6 SCREW5 6" HDU4 DBL 2X 15/1611 SB 5/8x24 55TB20 55TB24 10 SCREWS 6" HDU5 DBL 2X 1 5/16" 55 5/5x241 55TB24 55 5/8x24 14 SCREW5 6" HDUS 6X6 15/51, 515 Wax241 '/8x24155TB28 55TB34 20 SCREW5 8" HDUII 6X6 15/51, 1"36, NOTE 3 30 SCREWS 8" HDUI4 6X6 1 9/16" 1%, NOTE 3 56 SCREWS 8" SPAG I NG E.N. W STHDS/RJ DBL 2X 11/21, (24) Ibd 6" 5THD10/PJ DBL 2X 11/21, FTF STRAPOCCURS (28) Ibd 6" 5THDI4/PJ DBL 2X 11/21, o (38) Ibd 6" NOTES: I. HOLDOWN5 SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. 2. MIN EMBED FOR 51MP50N 55 5/8 AND 551/5 SHALL BE 18". SEE PLAN FOR EMBED IN ALL OTHER GASES. WHERE 3X SILL PLATE 15 REO'D AND 55TB BOLTS ARE USED, ORDER SSTB##L FOR LONGER THREAD LENGTH. 3. PROVIDE F1554 GR36 THREADED ROD WITH 28" MINIMUM EMBED IN MONOPOURED CONCRETE AND NUT WITH 1/2" THICK BY 3" 50. PLATE WASHER AT BOTTOM OF EMBEDDED END. 4. DOUBLE STUDS SHALL BE NAILED TOGETHER WITH 16d OR 12d (DIA.=0.131") AT b" O.G. STAGGERED. 5. STRAPS: MINIMUM FOUNDATION END DISTANCE FOR STRAP HOLDOWNS 15 11/2". NAIL 51ZE FOR STRAP HOLD01,61N5 IS Ibd SINKER (0.148" DIA. X 3 1/4" LENGTH) (__2__HOLDOW,N SCHEDULE SZ NO SCALE TOP PLATE AND SPLICE 3X STUDS WHERE 6 8 (5) 16d AT LAP WALL CORNER PER 4/52 EQ'D PER 5W5 53 53 SPLICE, TYP WHERE OCCURS :� I I`I I°I E.N. PER 5W5 L -L -L I I SHEAR PLY PER PLAN DATE DBL SIDED W SHEAR ALL SHEAR PLY PER PLAN 1 06.29.16 DBL SIDED SHEAR WALL 1/8" GAP PER MANUF., TYP 2 07.18.16 WHERE OCCURS WHERE OCCURS 1 .v W STUD H.D. PER SPAG I NG E.N. W E.N. WHERE OCCURS PLAN E.N. WHERE PER 5W5 FTF STRAPOCCURS FTF STRAP o PER PLAN PER PLAN INN— V BLKG A5 REQ'D c tA AT PANEL EDGES Cd E.N. - SHEAR PLY E N SHEAR PLY LL. z PER PLAN 0 PER PLAN I°I 0 Z �o SILL PLATE CONT. WALL :::..:: COMP. P05T CONT. WALL a COMP. POST PER SWS �Z WHERE OCCURS PER PLAN WHERE CURS ///`' PER PLAN 0 Wce I'I_ OG STRAP HOLDOWN 6 TYPICAL sT Z P/HD PIAN SECTION S2 NO SCALE IJ J I I I I F.N. SHERA FLYI PER PLAN J I . I° I� II II I RIM AT RAISED A.B. PER SWS FLOOR FND PER PLAN -` 12" MIN— L:LnTICALSHEAR WALL ELEVATION COMP. POST A REO'D PER HD SGHED. - HD PER PLAN A.B. PER HD SGHED. S2 1 S7n1ZYC0NDn70N NO SCALE /h -/D - PERMIT # BUTTE cREViEWED FOR sERvlcE CODE COMPLIANCE01 DATE ,v BY�.Y---- REV DATE BY 1 06.29.16 CMR 2 07.18.16 CMR 1 .v W W 0 Z INN— V M c tA Cd 0 LL. z 0 0 Z �o QV) a �Z 0 0 Wce 0WV J00 z :E Cie 0 W L.L.. � 0 c~n Z o I U WC) Z) �.. t� W z L 00 z N Imo, Wrz� i� Ln W trn FESS/ 39 -n .6-3 7 CIV�� Cr CAI- F JULY 18, 2016 Phase: PERMIT Ckd. By: CMR Date: � 04.12.16 Project #: 16-010 DRAWING NUMBER 2X6 CONT. WITH (5) Ibd NAILS EA EXISTING RAFTER E.N. 2X6 CONT. WITH (5) Ibd NAILS EA EXISTING RAFTER EXISTING RAFTER ROOF PLY 10 ',RAFTER TO EXISTING ROOF V LVL BL NEW RAFTER PLAN NO SCALE I (E) ROOF PLY SHEAR PLY PER PLAN TO MATCH WALL BELOW 2X PLATE WITH (5) I bd EA RAFTER Ibd 501-E NAILING TO 2X BLK PER 5W5 10 E.N. 14 2X BLOCK (E) ROOF FRAMING A35 WHERE OCCURS E.N. DBL TOP PLATE PER 4/S2 SHEAR PLY PER PLAN SHEAR PLY WHERE OCCURS AT "2-5IDE" GOND WALL FRAMING PER PLAN rl_J'N PONY WALL AT EXISTING ROOF S3 No scAr.E A 'OF RAFTER PER PLAN DBL TOP PLATE V LVL BL :AFTER TAIL 'OF RAFTER PER PLAN DBL TOP PLATE ZOOF RAFTER 'ER PLAN Z 4/52 'LAN VALL NO SCALE A IOd SINKERS ROOF PLY AT 8" O.G. PER PLAN A 2�fl fl E.N. + 2X RAFTER TAIL ONE SIDE OF RAFTER 5/8 SOFFIT CONT. SOFFIT VENT E.N. VERT. 2X4 UNDER TAIL LVL BLOCK WITH _GROVE VENT DIM SHAPED BLOCK PER PLAN DBL TOP PLATE PER 4/52 SHEAR PLY PER PLAN WALL FRAMING PER PLAN g� TYPICAL LOW EAVE DETAIL S3 NO SCALE ROOF PLY PER PLAN RAFTERS PER PLAN STRUCTURAL FASCIA E.N. E.N. -J LVL PER PLAN A55 AT 48" O.G. E.N. 2X WALL FRAMING PER PLAN ( r-- RAFTER PER PLAN RAKED DBL TOP PLATE PER 4/52 SHEAR PLY PER PLAN SHEAR AT IN51DE FACE WHERE OCCURS PER PLAN (E) CON I A55 AT 48" O.G. (E) FLOOR (E) FLOOR J015T (E) GIRDER WHERE OCCURS -- WALL FRAMING PER PLAN - SHEAR PLY PER PLAN SOLE NAILING E.N. (N) FLOOR PLY OR UNDERLAYMENT PER PLAN FLOOR J015T PER PLAN 12 " MIN (N) LU5 HANGER - LEDGER PER PLAN w/ (2) 1/4" DIA X 5" 5D5 SCREWS AT 1611 O.G. -. (E) FOUNDATOIN T_�LEDGER CONN. AT EXISTING FND DETAIL S3 NOTE: SEE 1/5 FOR MORE INFORMATION (E CON A35 AT 48" O.G. (E) FLOOR (E) FLOOR JOIST (E) GIRDER WHERE OCCURS WALL FRAMING PER PLAN - SHEAR PLY PER PLAN 2 FLASHING AND WATERPROOFING, B.0 =B -OT -NAILING E.N. () FLOOR PLY OR UNDERLAYMENT PER PLAN ir DECK .101ST PER PLAN z ` - LU HANGER EA 12" MIN JOIS =p11 LEDGER PER PLAN w/ (2) 1/4" DIA 6" MIN, X 511!505 SCREWS AT Ib" O.G U.N.O. #4 AT 24" O.G. HORIZ 4`- #4 AT 18" O.G. VERT WHERE STEM > 24"F. - 5" CLEAR 12" MIN —,� (1) #4 CONT. TOP AND BOTT 5 DECK LEDGER S3 / 'L'MIN— A35 AT PER PLAN ROOF PLY 48" O.G. E.N. NOTCH AROUND TOP FLANGE OF RAFTER (2) IOd NAILS RAFTERS PER PLAN 2X WALL FRAMING PER PLAN 'L' = 24" MAX 2X BLOCK FASCIA E.N. ��--- 2X OUTRIGGERS AT 24" O.G. RAKED DBL TOP PLATE PER 4/52 SHEAR PLY PER PLAN rq__ GABLE CONNECT ION AT LINE B 6 GABLE END DETAIL—WALL LINE A S3 NO SCALE S3 NO SCALE SHEAR AT INSIDE FACE WHERE OCCURS PER PLAN WALL FRAMING PER PLAN BLOCK SOLID AT POST AND H.D. SHEAR PLY PER PLAN 2X DECKING AND NAILING PER PLAN SOLE NAILING ' '.J :r E.N. y* r,¢ FLOOR JOIST PER PLAN RIM P.T. SILL AND Aff' ;; R' 5/52 E.N.-, SLAB ON GRADE s PER PLAN ,,,.� WHERE ; , OCCURS .,� , . cgs ' 0=,611 MIN, 6I!bPE FINISHED � &'RADE WAY FND. #4 AT 24" O.G. HORIZ #4 AT 18" O.G. VERT WHERE STEM > 24 5" CLEAR 4 12" MIN _4- (1) #4 CONT. TOP AND BOTT TYPICAL FO UNDAT ION DETAIL FLOOR PLY AND NAILING PER PLAN SOLID BLOCKING--\ GIRDER PER PLAN WITH BG POST GAP AT POSTS — 4Xb POST WITH (4) Ibd TOENAILS TO PIER — "WETSET" PRECAST f GONG. PIER NO SCALE FLOOR JOIST PER PLAN LAP b" ON CENTERLINE OF BIRDER (5) 8d TOENAILS PER F.J. z T T � W � I DIM PER PLAN FOUNDATION PER PLAN 2 INTERIOR FOUNDATION S3 1 POST PER PLAN POST BASE PER PLAN 5.0.6. PER PLAN 2" GLR MIN FINISHED DEPTH PER A4 '� GRADE PLAN J •4 REINFORCING 3" GLR WIDTH PER PER 50HED. PLAN W 1 TH 5L,A33 POST PER PLAN POST BASE PER PLAN 2" GLR MIN b" MAX - FINISHED DEPTH PER GRADE PLAN REINFORCING 5" GLR WIDTH PER PER SGHED. PLAN WITHOUT SLAB 3 FOUNDATIONAT EXTERIOR POST NO SCALE NO SCALE 6UTTE COUNTY DEVELOPMENT ���VIt✓E, REVIEWED FOR CODE COMPLIANCE REV DATE BY 1 06.29.16 CMR 2 07.18.16 CMR J W W V 0 W z 0 Z O c%i O Z 0 O W w 0� Wu 0./_Lu�` Lu J� u �..� VZ ce O W LLJ mac~ E �;- v,' ( u `Cu 64 •� W C).� L u ... Li zui � W _. z w rn yrE98l 4 >� EX 0-1 sT Civ OF CN - JULY 18, 2016 Phase: PERMIT Ckd. By: CMR Date: 04.12.16 Project #: 16-010 DRAWING NUMBER