HomeMy WebLinkAboutB16-1113 000-000-000GENERAL NOTES 1. GENERAL ALL WORK SHALL CONFORM TO THE 2013 CBC AND ALL APPLICABLE LOCAL CODES. THE ENGINEER HAS PROVIDED AND IS RESPONSIBLE FOR SPECIFIC STRUCTURAL ITEMS ONLY, ALL OTHER REQUIREMENTS OF THE BUILDING CODE INCLUDING WATERPROOFING, FIREPROOFING, DRAINAGE, HANDICAP ACCESSIBILITY, EGRESS REQUIREMENTS, PARKING, AND ALL OTHER DESIGN REQUIREMENTS NOT SPECIFICALLY SHOWN IN THE STRUCTURAL DESIGN CALCULATIONS ARE THE RESPONSIBILITY OF THE CONTRACTOR OR OWNER. SHOULD ANY CHANGES BE MADE FROM THE DESIGN AS SPECIFIED IN THESE DOCUMENTS WITHOUT THE WRITTEN APPROVAL FROM THE ENGINEER, THEN THE ENGINEER WILL ASSUME NO RESPONSIBILITY FOR ANY ELEMENT OR SYSTEM OF THE STRUCTURE. THE DRAWINGS AND CALCULATIONS REPRESENT THE FINISHED STRUCTURE, AND, UNLESS SPECIFICALLY NOTED OTHERWISE, DO NOT SHOW THE METHOD OF CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR THE METHOD OF CONSTRUCTION, AND SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE PUBLIC, CONSTRUCTION WORKERS, AND THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE FORMING, SHORING, BRACING, SCAFFOLDING, ETC. IF A PARTICULAR FEATURE OF CONSTRUCTION IS NOT FULLY SHOWN ON THE DRAWINGS OR IN THE CALCULATIONS, CENTI THEN IT SHALL BE CONSTRUCTED IN THE SAME CHARACTER AS SIMILAR CONDITIONS THAT ARE SHOWN ON THE DESIGN ANCH DOCUMENTS. TYPIC MFR ANY CONDITIONS NOTED AS EXISTING MUST BE FIELD VERIFIED BY THE CONTRACTOR, AND ANY DISCREPANCIES MUST EXAC BE BROUGHT TO THE ATTENTION OF THE ENGINEER WITHOUT PROCEEDING WITH CONSTRUCTION PRIOR TO THE DIMEP REVIEW OF THE ENGINEER. ALL WATERPROOFING AND FLASHING (ROOFS, FOUNDATIONS, GARAGE FLOORS, ETC...) IS THE RESPONSIBILITY OF THE CONTRACTOR OR OWNER. SPECIAL INSPECTION: SPECIAL INSPECTION PER SECTION 1705 OF THE CBC SHALL BE PROVIDED FOR THE FOLLOWING TYPES OF CONSTRUCTION: 1 HIGH STRENGTH BOLTING OF METAL BUILDING ABOVE THE SPECIAL INSPECTOR SHALL BE ACCEPTABLE TO THE ENGINEER OF RECORD AND BUILDING DEPARTMENT, SHALL BE 160 QUALIFIED, AND THEIR EXPERIENCE SHALT- BE COMMENSURATE WITH THIS TYPE OF PROJECT. SPECIAL INSPECTOR: BRAD FORSYTHE - APPLIED TESTING CONSULTANTS 1 2. SITE WORK / FOUNDATIONS TYP. EA ANCHOR ASSUMED MAXIMUM SOIL BEARING =1500 PSF (NO SOILS REPORT PROVIDED) FOUNDATIONS SHALL NOT BE SCALED FROM PLAN OR DETAIL DRAWINGS. FILL MATERIAL SHALL BE FREE FROM DEBRIS, VEGETATION, AND OTHER FOREIGN SUBSTANCES. USE 4" DIAMETER PERFORATED PIPE SUB -DRAIN BEHIND ALL RETAINING WALLS. SLOPE PIPE TO DRAIN TO DAYLIGHT. 3. CONCRETE / REINFORCING CONCRETE SHALL HAVE A MINIMUM 28 DAY STRENGTH OF 3,000 PSI U.N.O. (DESIGNED BASED ON 2500 PSI MIN.) ALL CEMENT USED SHALL CONFORM TO ASTM C-150 AND SHALL BE TYPE II OR TYPE III LOW ALKALI. AGGREGATE SHALL CONFORM TO ASTM C-33 AND SHALL NOT CONTAIN MATERIALS WHICH ARE ALKALI REACTIVE AS DETERMINED BY ASTM C-227,289, AND 295. IF TEST DATA IS UNAVAILABLE IN REGARDS TO ALKALI REACTIVE MATERIALS, PROVIDE CEMENT WITH A MAXIMUM ALKALI CONTENT LESS THAN 0.45% BY WEIGHT. CONCRETE EXPOSED TO FREEZING OR THAWING SHALL BE PROTECTED IN ACCORDANCE TO THE LATEST EDITION OF THE ACI CODE AND CBC APPENDIX, CHAPTER 19. REINFORCEMENT COVER SHALL BE AS FOLLOWS: CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO SOIL: 3" CONCRETE WITH SOIL OR WEATHER EXPOSURE: #5 BARS AND SMALLER 1 Y2" #6 BARS AND LARGER 2" CONCRETE WITHOUT SOIL OR WEATHER EXPOSURE: 3/4" REINFORCEMENT SHALL BE GRADE 60 PER ASTM A615 U.N.O. LAP REINFORCING 40 BAR DIAMETERS U.N.O. #5 AND LARGER REBAR SHALL NOT BE RE-BENT. ALL REINFORCING STEEL AND ANCHOR BOLTS SHALL BE ACCURATELY LOCATED AND ADEQUATELY SECURED IN POSITION BEFORE AND DURING CONCRETE PLACEMENT. ANCHOR BOLTS SHALL BE ASTM A 307 AND SHALL BE PROVIDED NEW, W/O EXCESSIVE RUST. CORROSION PROTECTION BY OTHERS GRAIN BIN WALL - ANCHOR BRACKET BY OTHERS 1" DIA. X 17" EMBED ASTM F1554 -GR. 36 THREADED ROD WITH (2) 2 3/4" SQ. X 1/2" SQUARE WASHER AND DOUBLE NUTS, TYP. o Z I � <r o 04 3" CLR ell _^ II I I I E 4'-0" DETAIL AT PERIMETER FOOTING NO SCALE 6" SLAB -ON -GRADE WITH #4 AT 18" 0 E.W. AT MID -DEPTH OF SLAB, TYPICAL. ° ••0�.0.° 00.E 01----0. -0 -1, 11 #4 AT 6" O.C. E.W. BOTTOM OR #5 AT 9 1/Z" O.C. E.W. BOTTOM OR #6 AT 13" O.C. E.W. BOTTOM I i I' REVIEWED IzOR CODE COMPLIANCE SEP 0 8 2016 INTERWEST CONSULTINr- r-r?ni m !JL 2 n 2016 I �;'ldES7/� �y Cel -11`{.}!'..I tN- i jl(ln!!p :slj BIN DESIGNED FOR WALNUT STORAGE ONLY! (20PCF MAXIMUM QRpVESS1049 C. 6 82z �C C/1 J� C/V1\- 9TFOF CA0 o7/2-1�14 THESE PLANS HAVE B EN REVIEWED FOR COMPLIANCE ONLY WITH THE ATTACHED STRUCTURAL CALCULATIONS 383 Rio Lindo Ave. Suite 200 Chico, CA 95926 P. 530.592.4407 SummitChico.com 0 hl t -i X U .s, a �.• UwCl DO O a J LL1= • u Z W' Lu CQ zz(D �~ r ^0' O! t� C) U fV .0 L!j m vi O Ln Z L J ICL. a ILLI LLJ z LLJ REVISIONS: Q1 RTPC #1 07/21/16 DATE: 04/18/16 SCALE: 1/8" =1'-0" DRAWN BY: ACJ JOB NUMBER: 16-191 SHEET: S1 �! '.i I I r I _