HomeMy WebLinkAboutB16-1251 000-000-000GENERAL ELECTRICAL NOTES
SMOKE DETECTOR NOTES:
I. AN EXHAUST HOOD 15 REQUIRED OVER TI -E GOOK STOVE AND MUST BE VENTED TO THE
1.
ALL SMOKE DETECTORS TO BE HARD WIRED W./
BACKUP.
EXTERIOR. THE HOOD 15 TO BE INSTALLED PER MANUFACTURER'S REQUIREMENTS WITHBATTERIES
2.
SMOKE DETECTORS ARE REQUIRED IN ALL EXISTING
CLEARANCES PER THE RAN6E/COOKTOP MANUFACTURER'S INSTALLATION. FOR DOWN
AIR TIGHT FLOUREGENT RECESSED FIXTURE
SLEEPING ROOMS AND THE HALLWAYS OR AREAS LEADING
DRAFT EXHAUST TYPE UNITS, INDICATE THE ROUTING OF THE UNDERFLOOR DUCT TO
O
TO EXISTING SLEEPING ROOMS.
POINT OF TERMINATION ('36" CLEAR LATERALLY FROM ANY OPENABLE WIND04
3.
IF NOT PRESENT ALL ROOMS TO BE BROUGHT TO CURRENT
AND A MIN. 100 CFM
C-0
CODE.
2. 200 AMP MAIN ELECTRICAL PANEL W/ METER, GAS SERVICE METER, MAIN GABLE TV
4.
ALL SMOKE DETECTORS TO COMPILE W/ ORO 8314 4 C315.
JUNCTION BOX AND MAIN TELEPHONE JUNCTION BOX SHALL TYPICALLY BE LOCATED
5.
ALL BEDROOM OUTLETS TO BE AFGI PROTECTED, INLUDIN6
ALONG THE SAME EXTERIOR WALL. FIELD VERIFY LOCATION OF SERVICES, PRIOR TO
120V DUPLEX RECEPTACLE W/ WEATHER PROOF
LIGHTS, PLUGS, SWITCHES LIGHTS AND SMOKE DETECTOR
START OF CONSTRUCTION AND SERVICES LOCATED IN SHEAR WALL5 SHALL BE APPROVEDOUTLETS.
6.
SMOKE ALARMS AND SMOKE DETECTORS SHALL NOT BE
BY ENGINEER OF RECORD, IF REQUIRED BY LOCAL JURISDICTION
GROUND FAULT CIRCUIT INTERRUPTER
LOCATED WHERE AMBIENT CONDITIONS, INCLUDING
3. PROVIDE TWO SMALL APPLIANCE CIRCUITS FOR THE KITCHEN, DINING ROOM, AND BREAKFAST
HUMIDITY AND TEMPERATURE, ARE OUTSIDE THE LIMITS
NOOK PER 2013 CEG. THE REQUIRED SMALL APPLIANCE CIRCUITS SHALL NOT
TAMPER-RE515TANT
SPECIFIED BY THE MANUFACTURER'S PUBLISHED
SUPPLY DISPOSAL, 0151-IWASHER, OR OTHER LARGE APPLIANCESINSTRUCTIONS.
1.
SMOKE ALARMS AND SMOKE DETECTORS SHALL NOT BE
4. BATHROOM RECEPTACLES SHALL BE SUPPLIED BY A SEPARATE 20 AMP CIRCUIT AND SHALL
LOCATED WITHIN UNFINISHED ATTICS OR GARAGES OR IN
OTHER SPACES WHERE TEMPERATURES CAN FALL BELOW
NOT HAVE EXHAUST FAN, LIGHTING OR OTHER OUTLETS ON IT PER ARTICLE 210-52 (c), NEC,
40°F (4°C) OR EXCEED (00°F (3b°C).
5. PROVIDE 4 -WIRE REGEPTAGLE5 FOR ALL RANGE, OVENS, AND CLOTHES DRYERS PER
b.
WHERE THE MOUNTING SURFACE COULD BECOME
ARTICLE 250-60, NEC,
CONSIDERABLY WARMER OR COOLER THAN THE ROOM,
SUCH AS A POORLY INSULATED CEILING BELOW AN
6. HVAC EQUIPMENT INSTALLED IN THE ATTIC SHALL COMPLY WITH THE FOLLOWING:
UNFINISHED ATTIC OR AN EXTERIOR WALL, SMOKE ALARMS
A. TRUSS ENC INEERIN6 SHALL SHOW LOADING FOR EQUIPMENT AND PLATFORM
AND SMOKE DETECTORS SHALL BE MOUNTED ON AN INSIDE
WALL.
LOCATION
g.
SMOKE ALARMS OR SMOKE DETECTORS SHALL
B. PLATFORM SHALL BE A MINIMUM OF 5/b' 0513 AND SHALL COMPLY WITH THE ACCESS
INSTALLED A MINIMUM OF 20FEET HORIZONTAL DISTANCE
REQUIREMENTS OF 2013 GMC,
FROM A PERMANENTLY INSTALLED COOKING APPLIANCE.
G. PROVIDE A MINIMUM OF 22"X30" ATTIC, ACCESS PER SECTION 2013 CMG
EXCEPTION: IONIZATION SMOKE ALARMS WITH AN ALARM
D. PROVIDE 120V SERVICE RECEPTACLE WITHIN 25' EQUIPMENT PER SECTION 2013 CMG
SILENCING SWITCH OR PHOTOELECTRIC SMOKE ALARMS
E. PROVIDE LIGHT AND SWITCH AT ATTIC ACCESS PER SECTION 2013 GMC,
SHALL BE PERMITTED TO BE INSTALLED 10 FEET 0 M) OR
GREATER FROM A PERMANENTLY INSTALLED COOKING
1. SMOKE DETECTORS SHALL BE WIRED IN TANDEM AND INSTALLED IN ACCORDANCE WITH
APPLIANCE. PHOTOELECTRIC, SMOKE ALARMS SHALL BE
SECTION 2013 CRO
PERMITTED TO BE INSTALLED GREATER THAN 6 FEET (I.b
M) FROM A PERMANENTLY INSTALLED COOKING
8. INCANDESCENT LIGHT FIXTURES IN WALK-IN CLOSETS SHALL BE 18" MINIMUM FROM FACIE OF:
APPLIANCE WHERE THE KITCHEN OR COOKING AREA AND
SHELVES. FLUORESCENT FIXTURES SHALL BE 6' MINIMUM FROM FACE OF SHELVES
ADJACENT SPACES HAVE NO CLEAR INTERIOR PARTITIONS
AND THE IOFT DISTANCES WOULD PROHIBIT THE
q. FLUORESCENT FIXTURES LOCATED IN THE KITCHEN AND BATHROOM SHALL BE CAPABLE OF
PLACEMENT OF A SMOKE ALARM OR SMOKE DETECTOR
PRODUCING 40 LUMENS PER WATT MAXIMUM
REQUIRED BY OTHER SECTIONS OF THE CODE. SMOKE
ALARMS L15TED FOR USE IN CLOSE PROXIMITY TO A
10. EXHAUST/LIGHT FANS INSTALLED OVER TUB AND OR TUB/SHOhER UNITS SHALL BE APPROVED
PERMANENTLY INSTALLED COOKING APPLIANCE.
FOR NET LOCATIONS
10.
INSTALLATION NEAR BATHROOMS. SMOKE ALARMS SHALL
II. EXHAUST FAN5 SHALL BE EQUIPED WITH BACKDRAFT CONTROL DAMPERS
BE INSTALLED NOT LESS THAN A 3FOOT (O.ql M)
HORIZONTAL DISTANCE FROM THE DOOR OR OPENING OF A
12. CARBON MONOXIDE DETECTOR TO BE INSTALLED PER. SECTION 8315 2013 ORO
BATHROOM THAT CONTAINS A BATHTUB OR SHOWER
13. BATHROOM EXAHU5T FAN TO BE ENERGY STAR LABELED PER ASHRAE 62.2
UNLESS THIS WOULD PREVENT PLACEMENT OF A SMOKE
ALARM REQUIRED BY OTHER SECTIONS OF THE CODE.
14. TAMPER-RE515TANT RECEPTACLES IN DI^ELLING UNITS. IN ALL AREA5 SPECIFIED IN THE 2013 CALIFORNIA
II.
SMOKE ALARMS AND SMOKE DETECTORS SHALL NOT BE
ELECTRICAL GORE ARTICLE 21052, ALL 125 -VOLT, 15- AND 20 -AMPERE RECEPTAGLE5 SHALL BE LISTED
INSTALLED WITHIN A 36 IN. (4110 MM) HORIZONTAL PATH
TAMPER-RE515TANT RECEPTACLES AS PER THE 2013 CALIFORNIA ELECTRICAL CODE ARTICLE 406.11.
FROM THE SUPPLY REGISTERS OF A FORGED AIR HEATING
OR COOLING SYSTEM AND SHALL BE INSTALLED OUTSIDE
15. FURNACE TO HAVE DEDICATED CIRCUIT PER GEC, 422.12
OF THE DIRECT AIRFLOW FROM THOSE RE615TER5.
16. GARAGE RECEPTICALS ARE TO BE MIN 18" A.F.F.
12.
SMOKE ALARMS AND SMOKE DETECTORS SHALL NOT BE
11. GEEILING RECEPTAGALS ARE TO BE GFI/GGFI CEC21052(0)
INSTALLED WITHIN A 36 IN. (4110 MM) HORIZONTAL PATH
18. PROVIDE CAULK OR GASKET 0 BATHROOM CEILING EXHAUST FANS PER GA ENERSY STD.
FROM THE BLADE OF A CEILING -SUSPENDED (PADDLE)
Iq. DRYER DUCT MAX. DEVELPOMENT OF 14'-0" W/ MAX. 2- q0° ELBOWS PER 2010 CHH 504.3.2.2
FAN.
20. DRYER DUCT TO TERMINATE NO CLOSER THAT 36" TO DOOR OR WINDOW PER CM40 5045
21. SEE CMG 802.2.2.4 4 101.2 - 101.3 FOR DRYER VENT AND COMBUSTION AIR REQUIREMENTS.
Residential Lighting Measures: INTERIOR & EXTERIOR
I. HIGH EFFICACY LUMINARIES OTHER THAN OUTDOOR HID: CONTAIN ONLY HIGH EFFIGAGY LAMPS A5
OUTLINED IN TABLE 150-6, AND DO NOT CONTAIN A MEDIUM SCREW BASE SOCKET OE24/E26). BALLAST
FOR LAMPS 13 WATTS OR GREATER ARE ELECTRONIC AND HAVE AN OUTPUT FREQUIENGY NO LESS THAN
20 KHZ
2. HIGH EFFICACY LUMINARIES - OUTDOOR HID: CONTAIN ONLY HIGH EFFIGAGY LAMPS AS OUTLINED IN
TABLE 150-0, LUMINARIES HAS FACTORY INSTALLED HID BALLAST
3. PERMANENTLY INSTALLED LUMINARIES IN KITGHEN5 SHALL BE HIGH EFFICACY LUMIMARIE5. UP TO 50
PERCENT OF THE WATTAGE, A5 DETERMINED IN 130 (G), OF PERMANENTLY INSTALLED LUMINARIES IN
KITCHENS MAY BE IN LUMINARIES THAT ARE NOT HIGH EFFIGAGY LUMINARIES, PROVfIDED THAT THESE
LUMINARIES ARE CONTROLLED BY SWITCHES SEPARATE FROM THOSE CONTROLLINI � THE HIGH EFFICACY
LUMINARIES.
4. PERMANENTLY INSTALLED LUMINARIES IN BATHROOMS, GARAGES, LAUNDRY ROOMS, UTILITY ROOMS SHALL
BE HIGH EFFIGAGY LUMINARIES. OR ARE CONTROLLED BY AN OCCUPANT SENSOR(5)) CERTIFIED TO
COMPLY WITH SECTION Ilq(D) THAT DOES NOT TURN ON AUTOMATICALLY OR HAVE ANN ALWAYS ON OPTION.
5. PERMANENTLY INSTALLED LUMINARIES LOCATED OTHER THAN IN KITCHENS, BATHRO>OM5, GARAGES,
LAUNDRY ROOMS, AND UTILITY ROOMS SHALL BE HIGH EFFICACY LUMINARIES (EXCEPT CLOSETS LESS
THAN 10FT2): OR ARE CONTROLLED BY A DIMMER SWITCH OR ARE CONTROLLED BY AN OCCUPANT
SENSOR THAT COMPLIES WITH SECTION INN THAT DOES NOT TURN ON AUTOMATICANLLY OR HAVE AN
ALWAYS ON OPTION.
6. LUMINARIES THAT ARE RECESSED INTO INSULATED CEILINGS ARE APPROVED FOR 2ZERO CLEARANCE
INSULATION COVER (IG) AND ARE CERTIFIED AIRTIGHT TO ASTM E283 AND LABELED AS AIR TIGHT (AT)
TO LE -55 THAN 2.0 CFM AT 15 PASCALS.
1. LUMINARIES PROVIDING OUTDOOR LIGHTING AND PERMANENTLY MOUNTED TO A RESIDENTIAL BUILDING OR
TO OTHER BUILDINGS ON THE SAME LOT SHALL BE HIGH EFFICACY LUMINARIES (NOTE INGLUDINe LIGHTING
AROUND SWIMMING POOLS/WATER FEATURES OR OTHER ARTICLE 680 LOCATIONS) I OR ARE CONTROLLED
BY OCCUPANT SENSORS WITH INTEGRAL PHOTO CONTROL CERTIFIED TO COMPLY WIITH SECTION IWO).
8. LIGHTING FOR PARKING LOTS FOR 8 OR MORE VEHICLES SHALL HAVE LIGHTING THAT COMPLIES WITH
5EC. 130, 132, AND 141. L16HTING FOR PARKING GARAGE5 FOR 8 OR MORE VEHICUES SHALL HAVE
LIGHTING THAT COMPLIES WITH SEG. 130, 131, AND 146.
q. PERMANENTLY INSTALLED LIGHTING IN THE ENCLOSED, NON -DWELLING 5PACE5 OF LLOW-RISE RE51DENTIAL
BUILDINGS WITH FOUR OR MORE DWELLING UNITS SHALL BE HIGH EFFICACY LUMINARIES OR ARE
CONTROLLED BY OCCUPANT SENSOR(5) CERTIFIED TO COMPLY WITH SECTION Ilq(D).
ASHRAE STANDARD 62.2
Q LOCAL EXHAUST FAN
O WHOLE HOUSE EXHAUST FAN
MIN. GFM MIN. DUCT EXHAUST FAN LOCATION
50 4" ® 10' BATHROOM
100 50055, KITCHEN
56 4" 0 10' WHOLE HOUSE
THE WHOLE BUILDING VENTILATION EXHAUST FAN WILL OPERATE CONTINUOUSLY (GENERoAL EXHAUST FAN)
AND 15 REQUIRED TO BE RATED FOR SOUND AT A MAXIMUM OF I SONE. TH15 EXHAU5T F=AN CAN BE
CONTROLLED BY A STANDARD ON/OFF 5WITGH BUT THE 5WITGH MUST BE LABELED TO INFORM THE
OGGUPANT THAT THE EXHAUST FAN 15 THE WHOLE BUILDING VENTILATION EXHAUST FAN SAND 15 INTENDED
TO OPERATE CONTINUOUSLY. THE WORDING NEEDS TO MAKE CLEAR WHAT THE GONTROLL 15 FOR AND THE
IMPORTANCE OF OPERATING THE 5Y5TEM. TH15 MAY BE AS 51MPLE AS "VENTILATION GCONTROL" OR MIGHT
INCLUDE WORDING SUCH AS; "OPERATE WHEN THE HOUSE 15 IN USE" OR "FAN 15 ON FOR IINDOOR AIR
QUALITY" MAJORITY OF LOCAL EXHAUST FANS (BATHROOMS � KITCHEN) WILL OPERATE_ INTERMITTENTLY
AND ARE REQUIRED TO BE RATED AT MAX. 3 50NE5.
ELEECTRICAL PLAN
50AI Ft 1/4" = 1'-0"
ELECTRICAL LEGEND
IFLUORSESGENT FIXTURE
CONDENSING UNIT
SEER: SEE T-24
HP/
DIGONNEGT
HVAC EQUIPMENT IN THE ATTIC:
(1) ACCESS OPENING LARGE ENOUGH TO
REMOVE THE LARGEST PIECE OF EQUIPMENT
BUT NO SMALLER THAN 30-INCHE5 X 22 -INCHES.
(2) AN UNOBSTRUCTED PASSAGEWAY LARGE
ENOUGH TO REMOVE THE LARGEST PIECE OF
EQUIPMENT BUT NO SMALLER THAN
30 -INCH X 30 -INCH MINIMUM, RUNNING FROM
THE ACCESS OPENING TO THE PIECE OF EQUIPMENT
IN ATTIC.
0) A SOLID, 24 -INCH WIDE PLATFORM
PATH FROM AC -CE -55 OPENING TO EQUIPMENT BUT
NO MORE THAN 20 -FEET LONG.
(4) A LEVEL SERVICE
SPACE AT LEAST 30 -INCHES DEEP AND 30 -INCHES
WIDE LOCATED AT THE FRONT OR SERVICE SIDE OF
THE EQUIPMENT.
(5) A SERVICE RECEPTACLE WITHIN 25 -FEET OF
EQUIPMENT ON THE LINE SIDE OF THE REQUIRED
EQUIPMENT DISCONNECT.
(6) A LIGHT ILLUMINATING THE EQUIPMENT AND
APPROACH CONTROLLED BY A SWITCH AT THE
ACCESS OPENING.
GMC, 305, CMG 30q, GMC, g03.0, CMG gOb.O d CEG 210-10(M-3)
BUTTE COUNTY SPECIAL NOTES:
EACH BATHROOM SHALL BE MECHANICALLY VENTILATED AND SHALL COMPLY WITH THE FOLLOWING:
I. FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE OUTSIDE THE BUILDING.
2. UNLE55 FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, FANS MUST BE CONTROLLED BY A HUMIDITY
CONTROL.
a. HUMIDITY CONTROLS SHALL BE CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGE OF:j 50 PERCENT TO A
MAXIMUM OF 80 PERCENT. A HUMIDITY CONTROL MAY UTILIZE MANUAL OR AUTOMATIC, MEANS OF ADJUSTMENT.
b. A HUMIDITY CONTROL MAY BE A SEPARATE COMPONENT TO THE EXHAUST FAN AND 15 NOT REQUIRED TO BE INTEGRAL (LE.,
BUILT-IN).
"�- - -•I I * 1 (@ so
z
(\*PJAV MOTION
HOTO CELL
0
INso
CIO
•'J
PERMIT # � 125 l
BUTTE COUNTY DEVELOPMENT SERVICES
REVIEWED
CODEC MPLIAONCE
DATE �� -�� BY
TER HEATER.
2.PROVIDE PRESSURE RELIEF VALVE WITH
DRAIN TO OUTSIDE FOR WATER HEATER.
3.PROVIDE SEISMIC STRAPPING IN THE UPPER 3
WH KJ47 LOWER THIRD OF THE WATER HEATER A MINIMUM
OF 4" ABOVE CONTROLS.
4. INSULATE THE FIRST V OF HOT/GOLD WATER
IR LINES FROM THE WATER HEATER. (150(-1)(2))
. MOTION
PHO TO
ANN
Q qo
CD��
REVISIONS BY
lee
i
UL
z
U
In
lu
lu
v
v
- Q
..nn
V`
O
I•N
V
N'E
w'E.
0QWU
06 Z U 8
ZNa
a
z uQ-
JIMLL
�paa
V
DATE:
6/05/16
scrtiE:
AS SHOWN
EMANN,
DG
JOB:
N)I
M�351-66P� 244
sf-Eu -
EI
INCANDESCENT FIXTURE
FLUOR
FLUORESCENT FIXTURE
®
AIR TIGHT FLOUREGENT RECESSED FIXTURE
❑®
EXHAUST FAN 50OFM 5EE BG SPECIAL NOTES
O
SMOKE DETECTOR
5D
❑°
CARBON MONOXIDE DETECTOR
C-0
SWITCH
3- WAY SWITCH
B& 2WV
220V APPLIANCE RECEPTACLE
►� 6Fi
120V DUPLEX RECEPTACLE W/ WEATHER PROOF
GROUND FAULT CIRCUIT INTERRUPTER
::c 6Fl
120V DUPLEX RECEPTACLE W/
GROUND FAULT CIRCUIT INTERRUPTER
120V DUPLEX RECEPTAOI F W/
ARG FAULT GIRGUIT INTERRUPTER
TAMPER-RE515TANT
CONDENSING UNIT
SEER: SEE T-24
HP/
DIGONNEGT
HVAC EQUIPMENT IN THE ATTIC:
(1) ACCESS OPENING LARGE ENOUGH TO
REMOVE THE LARGEST PIECE OF EQUIPMENT
BUT NO SMALLER THAN 30-INCHE5 X 22 -INCHES.
(2) AN UNOBSTRUCTED PASSAGEWAY LARGE
ENOUGH TO REMOVE THE LARGEST PIECE OF
EQUIPMENT BUT NO SMALLER THAN
30 -INCH X 30 -INCH MINIMUM, RUNNING FROM
THE ACCESS OPENING TO THE PIECE OF EQUIPMENT
IN ATTIC.
0) A SOLID, 24 -INCH WIDE PLATFORM
PATH FROM AC -CE -55 OPENING TO EQUIPMENT BUT
NO MORE THAN 20 -FEET LONG.
(4) A LEVEL SERVICE
SPACE AT LEAST 30 -INCHES DEEP AND 30 -INCHES
WIDE LOCATED AT THE FRONT OR SERVICE SIDE OF
THE EQUIPMENT.
(5) A SERVICE RECEPTACLE WITHIN 25 -FEET OF
EQUIPMENT ON THE LINE SIDE OF THE REQUIRED
EQUIPMENT DISCONNECT.
(6) A LIGHT ILLUMINATING THE EQUIPMENT AND
APPROACH CONTROLLED BY A SWITCH AT THE
ACCESS OPENING.
GMC, 305, CMG 30q, GMC, g03.0, CMG gOb.O d CEG 210-10(M-3)
BUTTE COUNTY SPECIAL NOTES:
EACH BATHROOM SHALL BE MECHANICALLY VENTILATED AND SHALL COMPLY WITH THE FOLLOWING:
I. FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE OUTSIDE THE BUILDING.
2. UNLE55 FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, FANS MUST BE CONTROLLED BY A HUMIDITY
CONTROL.
a. HUMIDITY CONTROLS SHALL BE CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGE OF:j 50 PERCENT TO A
MAXIMUM OF 80 PERCENT. A HUMIDITY CONTROL MAY UTILIZE MANUAL OR AUTOMATIC, MEANS OF ADJUSTMENT.
b. A HUMIDITY CONTROL MAY BE A SEPARATE COMPONENT TO THE EXHAUST FAN AND 15 NOT REQUIRED TO BE INTEGRAL (LE.,
BUILT-IN).
"�- - -•I I * 1 (@ so
z
(\*PJAV MOTION
HOTO CELL
0
INso
CIO
•'J
PERMIT # � 125 l
BUTTE COUNTY DEVELOPMENT SERVICES
REVIEWED
CODEC MPLIAONCE
DATE �� -�� BY
TER HEATER.
2.PROVIDE PRESSURE RELIEF VALVE WITH
DRAIN TO OUTSIDE FOR WATER HEATER.
3.PROVIDE SEISMIC STRAPPING IN THE UPPER 3
WH KJ47 LOWER THIRD OF THE WATER HEATER A MINIMUM
OF 4" ABOVE CONTROLS.
4. INSULATE THE FIRST V OF HOT/GOLD WATER
IR LINES FROM THE WATER HEATER. (150(-1)(2))
. MOTION
PHO TO
ANN
Q qo
CD��
REVISIONS BY
lee
i
UL
z
U
In
lu
lu
v
v
- Q
..nn
V`
O
I•N
V
N'E
w'E.
0QWU
06 Z U 8
ZNa
a
z uQ-
JIMLL
�paa
V
DATE:
6/05/16
scrtiE:
AS SHOWN
EMANN,
DG
JOB:
N)I
M�351-66P� 244
sf-Eu -
EI