Loading...
HomeMy WebLinkAboutB16-1237 042-020-104Codes and Loads WHEN MULTIPLE BUILDINGS ARE INVOLVED, SPECIFIC LOAD FACTORS FOR DIFFERING OCCUPANCIES, BUILDING DIMENSIONS, HEIGHTS, FRAMING SYSTEMS, ROOF SLOPES, ETC., MAY RESULT IN DIFFERENT LOAD APPLICATION FACTORS THAN INDICATED BELOW. SEE CALCULATIONS FOR FURTHER DETAILS. WIND LOADS ARE APPLIED TO OVERALL BUILDING ENVELOPE. COMMON WALLS BETWEEN CONNECTED SHAPES ARE NOT SUBJECT TO EXTERNAL WIND LOADS. City: Chico County: Butte State: California Country: United States Building Code Building Code: CA13 Structural: 10AISC - ASD Rainfall: I: 0.10 inches per hour Based on Building Code: 2012 International Building Code Cold Form: 12AISI - ASD f'c: 3000.00 psi Concrete Building Risk/Occupancy Category: II (Standard Occupancy Structure) Dead and Collateral Loads Material Dead Weight Roof Live Load Collateral Gravity:5.00 psf Roof Covering + Second. Dead Load: Varies Roof Live Load: 20.00 psf Reducible Collateral Uplift: 0.00 psf Frame Weight (assumed for seismic):2.50 psf Wind Load Wind Speed: Vult: 110.00 (Vasd: 85.21) mph The 'Envelope Procedure' is Used Wind Exposure: C - Kz: 0.932 Parts Wind Exposure Factor: 0.932 Wind Enclosure: Enclosed Topographic Factor: Kzt: 1.0000 NOT Windborne Debris Region Base Elevation: 0/0/0 Primary Zone Strip Width: 2a: 13/0/0 Parts / Pcrtions Zone Strip Width: a: 6/6/0 Basic Wind Pressure: q: 24.55 psf Snow Load Ground Snow Load: pg: 0.00 psf Flat Roof Snow: pf: 0.00 psf Design Snow (Sloped): ps: 0.00 psf Rain Surcharge: 0.00 Exposure Factor: 2 Partially Exposed - Ce: 1.00 Snow Importance: Is: 1.000 Thermal Factor: Unheated - Ct: 1.20 Ground / Roof Conversion: 0.70 Unobstructed, Slippery Seismic Load Lateral Force Resisting Systems using Equivalent Force Procedure Mapped MCE Acceleration: Ss: 61.80 %g Mapped MCE Acceleration: S1: 27.60 %g Site Class: Stiff soil (D) Seismic Importance: Ie: 1.000 Design Acceleration Parameter: Sds: 0.5379 Design Acceleration Parameter: Shc: 0.3400 Seismic Design Category: D Seismic Snow Load: 0.00 psf % Snow Used in Seismic: 0.00 Diaphragm Condition: Flexible Fundamental Period Height Used: 18/0/0 Transverse Direction Parameters Ordinary Steel Moment Frames Redundancy Factor: Rho: 1.30 Fundamental Period: Ta: 0.2827 R -Factor: 3.50 Overstrength Factor: Omega: 2.50 Deflection Amplification Factor: Cd: 3.00 Base Shear: V: 0.1537 x W Longitudinal Direction Parameters Ordinary Steel Concentric Braced Frames Redundancy Factor: Rho: 1.30 Fundamental Period: Ta: 0.1748 R -Factor: 3.25 Overstrength Factor: Omega: 2.00 Deflection Amplification Factor: Cd: 3.25 Base Shear: V: 0.1655 x W /i I� {J C 6 7 794 -7 ,- l < sj'9T CIVIC e���P �F CAO ( VPC FILENAME: 16008721-oi 47 Y THE BUTLER MFG. ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF BUTLER MFG. AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY BUTLER. THE BUTLER MFG. ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY BUTLER EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY BUTLER. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF BUTLER MFG. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF BUTLER MFG.JOB BUTLER MANUFACTURING 1540 GENESSEE ST. KANSAS CITY, MO 64102 CODES AND LOADS REV: DATE BY: DESCRIPTION:BUILDER: North Valley Building Systems, Inc. CUSTOMER: LOCATION:Chico, Chi co, California PROJECT: Gig 7 Crop Insurance BUILDER'SPOA a dvielnn BUTLER Butler Manufacturing VPCVERslort 2016.1 d BlueS000e Build nos North Arrerlca. Inc. B 16-008721-01 THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE BUTLER MFG. ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. DATE: 5/11/2016 DRECK / JILD RFG PAGE: 1 2 DRAVNNGSCALE: NTS VPC FILENAME: 16008721-oi 47 Y BUILDER/CONTRACTOR RESPONSIBILITIES Butler Nifg. follows the guidelines as outlined in the AISC and MBMA Codes of Standard Practice. Butler Mfg. staixdard product specifications, design, fabrication, quality criteria shall govern all work unless stipulated otherwise in the contract documeres. In case of discrepancies between Butler Mfg. structural plans and plans for other trades, Butler Mfg. structural plans shall govern. it is the responsibility of the Builder to obtain approvals and permits froin all governing agencies and jurisdictions as required. Approval of Butler Mfg drawings constitutes the builders acceptance of Bugler interpretation of the contract purchase order. Unless specific design criteria concerning interface design and details are furnished as part of the contract, Butler Mfg. design assumptions shalt govern. Butier engineers are not Project Engineers or Engineer of Record for the overall project. Butler engineering supply sealed engineering design data and drawings for Butler supplied material as part of tl ie overall project for use by others to obtain permits, approvals, and coordinate with other trades. The Builder or A/E firm are responsible for the overall project coordination, including coordination with appropriate inspection and testing agencies. All interface and/or compatibility of any materials not furnished by Butler are to be considered and coordinated by the builder or A/E firm. CONSTRUCTION & ERECTION RESPONSIBILITY The Builder is responsible for construction in strict accordance with Butler Mfg. "FOR CONSTRUCTION" drawings and all applicable product installation guides. Bober is not responsible for work done from arty other Butler drawings that are not marked "FOR CONSTRUCTION", nor any drawings prepared by others. As erected field assemblies of members shall be as specified in MBMA Code of Standard Practice (in Canada - CSA S16), which require U5W tolerance of installed members. Occasional field work including shimming, cutting, coping, and drilling for final fit -up are considered part of erection. Specified field work and field welding conditions indicated on these drawings shall also be included in the erectors scope of work. See Erection Guide for shimming procedure. For b.iilding with top riding bridge cranes see Crane Data drawing for column plumb tolerance. The builciing erector shall be properly licensed and experienced in erecting metal building systems. The Builder is responsible for having knowledge of, and shall comply with, all OSHA requirements and all other governing site safety criteria. The builder is responsible for designing, supplying, locating and installing temporary supports and bracing during erection of the building. Butler bracing is designed for code required loads after building completion ai id shall not be considered as adi�quate erection bracing. See Erection Guide. EXIST ING STRUCTURES Butler must be advised of any existing structure that is within 20 ft. of i3utler's building. Loadinc,s of both buildings may be affected wlien adjacent buildings ore within this distance. Butler cannot be responsible for the design or loading of existing buildings. BRACING Te[rjion brace rods work in pairs to balance forces caused by initial tensioning. Care must be taken wl pile tigl itening brace rods so as not to cause accidental or misalignment of components. All rods must be installed loose and then tightened. Rods should not exhibit excessive sag. For long or heavy rods, or angles it may be necessary to support the rods at mid -bay by suspending there from secondary members. Bracing for seismic or wind loading of objects or equipment that are not a part of the Butler structure must be designed by a qualified professional to deliver lateral loads to primary frames and rod bracing struts. Equipment bracing and suspension connections must not impose torsion or mi,)or axis loads, or cause local distortion in any Butler components. Butler accepts no responsibility for design or installation of bracing systems not furnished by Butler. FIELD WELDING All field welding shall be done at the direction of a design professional, and done in accordance with governing requirements (AWS in USA, CWB in Canada) by welders qualified to perform the welding as directed by the applicable welding procedure specification (YIPS). A WPS shall be prep[.: red by the contractor for each welding variation specified. Tlie co[ itractor is responsible for any special welding inspection as required by local jurisdiction. Filler metal shall be 70 ksi (480 MPa) tensile strength. For welds in high seismic force resisting system (Seisinic Cat D, E or F), minimum Charpy V -Notch toughness shall meet AISC-341 criteria (20 ft -lbs min @ ODeg F). Interpass temperatures shall not exceed 55ODeg F (30ODeg C). SIGNAGE Thr; Gunder is responsible for furnishing signs as required by Codi ai id the Building Department, including but not limited to, exits, occupancy limits, floor loading limits, and bulk storage limits. Floor loading signs shall clearly indicate maximum floor live load permitted. Bulk storage facilities shall have signs clearly posted on all loaded walls indicating the type of cu.ninod;ty stored and the maximum storage height. Signs shall be clearly visible when building is fully loaded to design level. Overloading of floors or walls may result in failure. DELIVERIES It is the responsibility of the builder to have adequate equipment available at the job site to unload trucks in a safe and timely manner. The Builder will be responsible for all retention charges from carriers as a result of job site unloading delays. Claims for damage or shorts MUST be noted on the Bill -of -Lading or delivery receipt and filed against the carrier by the consignee as per Butler's Terms of Sales (F.O.B. Plant) under the Uniform Commercial Code. It is critical that damages or shorts be noted on the Bill -of -Lading or you have little recourse with the carrier. Immediately upon delivery of material, material quantities are verified by the Builder against quantities billed on the shipping document. Neither the Manufacturer nor the carrier is responsible for material shortages against quantities billed on the shipping document if such shortages are not noted on the shipping documents upon delivery of material and acknowledged by the carriers agent. For materials concealed in bundles, boxes, or crates, shortages must be reported immediately upon unpacking. Should products get wet, bundled and crated materials must be unpacked and unbundled immediately to provide drainage of trapped moisture. See Erection Guide for proper job site storage procedure. SEALANTS Sealants shall be applied in strict accordance with Butler details or weather tightness will be compromised. Sealant must be applied in temperatures and weather conditions consistent with labeling. INDEPENDENT MEZZANINES Independent mezzanines must be designed by a professional engineer. The engineer must ensure that proper isolation from the Butler building has been provided to avoid structural damage due to differential movements, or inadvertently apply loads to the Butler structure. Butler accepts no responsibility for the design of the independent mezzanine. FIRE CODE COMPLIANCE ft is the responsibility of the project design professional and builder to comply with local fire code regulations including consideration of, but not limited to, building use and occupancy, all building construction materials, separation requirements, egress requirements, fire protection systems, etc. Builder shall advise Butler of any special requirements to be furnished by Butler. FIELD MODIFICATIONS Modifications to this building from details and instructions contained on these drawings must be approved in writing by Butler Mfg. engineers, or other licensed structural engineer. This includes, but is not limited to, removal of roof or wall cladding, removing or moving any flange braces or rod braces, cutting of openings for doors, windows or RTU's, correction of fabrication errors, etc. TIv owner shall not impose loads to this structure beyond what is specified for this building in the contract documents. Butler Mfg. accepts no responsibility for the consequences of any unauthorized additions, alterations, or added loads to this structure. If tine builder intends to invoice Butler Mfg. for modifications in excess of $1000, The builder inust notify Butler Mfg. immediately, and obtain a Work Authorization from Butler Mfg prior to proceeding. All final claims must be submitted to Butler Mfg with all supporting documentation rtiitlun 30 days of the building completion. Claims submitted without work authorizations, or after 30 days will not be accepted. Correction of minor misfits, shimming and plumbing, moderate amount of reaming, drilling, chipping / cutting and minor welding are considered by Code of Standard Practice to be part of erection are not subject to claim reimbursement. CONCRETE/MASONRY/CONVENTIONAL STUD WALLS The engineer responsible for the design of the wall system is responsible for coordinating with, or specifying to Butler Mfg, any wall to steel compatibility issues such as drift and deflection compatibility, special base details, and wall to Butler steel connections. All fasteners, sealant and counter flashing of wall systems are to be provided by contractor. The engineer responsible for tine wall shall design the anchorage to Butler supporting elements consistent with Code required forces. PANELS Oil canning is an inherent characteristic of cold formed steel panels. It Is the result of several factors that include induced stresses in the raw material delivered to Butler, fabrication methods, installation procedures, and post installation thermal forces. Thru fastened panels will exhibit some dimpling when installed, especially when insulation is Installed between panels and secondary supports. Dimpling can be minimized by careful installation, taking care not to over drive fasteners. Roof rumble is a phenomenon that is caused by wind gusts lifting up on the roof panels and then springing back into place. All panels experience this action to some degree, especially with concealed clip Standing Seam panels. Roof rumble noise may be minimized by providing a layer of blanket insulation between the panels and any hard support surface such as steel secondary members, substrates such as plywood, steel decking, or rigid board insulation. A minimum of 3 inch thick blanket is recommended over steel secondary members, or 2 inch over substrates. Oil canning, dimpling, and roof rumble do not affect the structural integrity or weather tightness of the panels and is not grounds for rejection of panels. The Standing Seam joint detail is designed with an interlocking feature for ease of installation. However, it is imperative that installed Standing Seam panels be secured to the secondary structural members and properly seamed prior to departure from the job site each day. SKYLIGHTS Local building departments may require added fall restraint due to conditions that may affect the skylight structural integrity. It is the responsibility of the builder to determine and provide any added fall restraint under the skylight as may be required by your building department. RAIN WATER RUNOFF Drainage systems must be designed by the project professional to comply with code requirements. Butler is not responsible for drainage designs, overflow scuppers, down piping, etc. The project professional and contractor are responsible to ensure that primary drains and overflow devices such as scuppers and auxiliary drains are provided as required for the required rain intensity at the building perimeter and at valley conditions to prevent ponding. STEEL SHOP COAT The purpose of Butler's shop coat is to provide protection for the steel members during transportation, during temporary job site storage and during erection. Standard shop formulation Is not designed to perform as a finish coat when exposed to environmental conditions. Members shall be kept free of the ground and properly drained during job site storage. It is the Builder's responsibility to ensure that if a finish coat is being applied over Butler shop coat that the painting contractor verifies compatibility between his finish coat and Butler's shop coat. BUTLER MFG. ACCREDI TATiONS AND APPROVALS Fabricator Approvals IAS AC472 Approvals: (www.iasonfine.org/Metal_Building_Systems/M&html) Listed under BlueScope Buildings North America, Inc. City of Los Angeles, CA #FB00031; City of Houston, TX 767; City of Phoenix, AZ C19-02008; Clark County 43 & 833 Design Approvals IAS AC472 Approvals: (www.lasonline.org/Metal_Building_Systems/MalAml) Listed under Butler Manufacturing, a Division of BlueScope Buildings North America, Inc. Canadian CSA A660 Certifications (http:leng.cwbgroup.org/CertificatiorVPages/Certif iedCompanySearch.aspx) Listed under BlueScope Buildings North America, Inc. Engineering Certifications of Authorization USA--AR#576; FL#30427; ID#C-2470; IL#184-002649; KS#E-29; MS#E-0592; MO#E-2010007736; NC#F-0998; OK#CA417OPE; SD#C-1787; TX#F4828; WV#C03059-00; CAN--AB#P08900; NS#30123; ON#100148796; and YT#PP134 Cn U u 3 f C 677.4 C-) 6 s -A�- S D/ sTq , CIV O- c�P �F CALXF ' THE BUTLER MFG. ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF BUTLER MFG. AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY BUTLER. THE BUTLER MFG. ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY BUTLER EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY BUTLER. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF BUTLER MFG. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF BUTLER MFG.JOB* BUTLER MANUFACTURING 1540 GENESSEE ST. KANSAS CITY, MO 64102 ERECTION NOTES REv. DATE' BY: DESCRIPTION BuuDER: North Valley Building Systems, Inc. CUSTOMER: LOCATION: Chico, California QCT Gig 7 Crop Insurance BUILDER'SMt. a dvision BUTLER 16-008721-01 THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE BUTLER MFG. ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. DATE: 5/11/2016 /CHECK JLD RFG Butler Manufacturing g 1PCVERSION: 2016.1 of BlueSoope Buildngs North Amedea. Inc. PAGE:DRAM PAGE: 3 DRAWNGSCALE: NTS VPC FILENAME 16_:,87,21-c1 A Butler Manufacturing a divisioti of BlueSeope Buildings North America. Inc. R DRAWING INDEX DRAWING TITLE COVE=R SHEET NOTES ANCHOR ROD PLAN PRIMARY STRUCTURAL SECONDARY STRUCTURAL COVERING SPECIAL DRAWINGS STANDARD ERECTION DETAILS PLANOGRAPH DETAILS PAGES II 1 2.3 4 5-14 15-21 PERMIT DRAWINGS DRAWING RELEASE HISTORY TYPE DATE I DESCRIPTION 5/11/2016 1 PERMIT SET- For Building Dept. Approval GENERAL NOTES MATERIALS ASTM DESIGNATION 3 PLATE WELDED SECTIONS A529, A572, A1011, A1018 GRADE 55 COLD FORMED LIGHT GAGE SHAPES A653, A1011 GRADE 60 BRACE RODS A572, A510 GRADE 50 HOT ROLLED MILL SHAPES A36, A529, A572, A588, A992 GRADE 36 OR 50 HOT ROLLED ANGLES A529, A572, A588, A992 GRADE 50 HOLLOW STRUCTURAL SECTION (HSS) A500 GRADE B CLADDING A653, A792 GRADE 50 OR GRADE 80 HIGH STRENGTH BOLT TIGHTENING REQUIREMENTS IT IS THE RESPONSIBILITY OF THE ERECTOR TO ENSURE PROPER BOLT TIGHTNESS IN ACCORDANCE WITH APPLICABLE REGULATIONS. SEE RCSC SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH STRENGTH BOLTS FOR MORE INFORMATION. SEE ERECTION GUIDE FOR BOLT TIGHTENING INSTRUCTIONS. THE FOLLOWING CRITERIA MAY BE USED TO DETERMINE THE BOLT TIGHTNESS (I.E.-SNUG TIGHT OR PRE -TENSION) UNLESS REQUIRED OTHERWISE BY LOCAL JURISDICTION OR CONTRACT. ALL A490 BOLTS SHALL BE "PRE -TENSIONED". A325 BOLTS IN PRIMARY FRAMING AND BRACING CONNECTIONS MAY BE "SNUG -TIGHT" EXCEPT AS FOLLOWS; PRE -TENSION A325 BOLTS IF BUILDING SUPPORTS A CRANE GREATER THAN 5 TON CAPACITY. PRE -TENSION A325 BOLTS IF BUILDING SUPPORTS MACHINERY THAT CREATES VIBRATION, IMPACT, OR STRESS REVERSALS ON CONNECTIONS. PRE -TENSION A325 BOLTS IF LOCATED IN HIGH SEISMIC AREAS. FOR IBC BASED CODES; HIGH SEISMIC IS DESIGN CATEGORY D, E OR F. SEE CODES AND LOADS SECTION BELOW FOR DETAILS. PRE -TENSION ANY CONNECTION WITH DESIGNATION A325 -SC. SLIP CRITICAL (SC) CONNECTIONS MUST BE FREE OF PAINT, OIL OR OTHER MATERIALS THAT REDUCE FRICTION AT CONTACT SURFACES. GALVANIZED OR LIGHTLY RUSTED SURFACES ARE ACCEPTABLE. IN CANADA, ALL A325 AND A490 BOLTS SHALL BE "PRE -TENSIONED', EXCEPT FOR SECONDARY MEMBERS AND FLANGE BRACES. SECONDARY MEMBERS AND FLANGE BRACE CONNECTIONS ARE ALWAYS "SNUG TIGHT-, UNLESS INDICATED OTHERWISE IN ERECTION DRAWING DETAILS. B U TTE COUNTY JUN @ 9' 2016 DEVELOPMENT SERVICE 0) & - I -�,9A r— �jvs, t�`...J `-J L cn ! � = C67794 asl C/V 11- ��\P FBF CAL1F0 THE BUTLER MFG. ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF BUTLER MFG. AND DESIGN AND PERFORIv1ANCE REQUIREMENTS SPECIFIED BY BUTLER. THE BUTLER MFG. ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY BUTLER EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY BUTLER. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF BUTLER MFG. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF BUTLER MFG.JOBt BUTLER MANUFACTURING 1540 GENESSEE ST. KANSAS CITY, MO 64102 COVER SHEET _... __._ r BUTLER Butler Manufacturin 9 VPCVERSION 2016.1 of BlueSeope Buildngs North Amerlea, Inc. -- THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING. DETAILS REFERENCED IN THIS DRAWING. ALL APPLICABLE BUTLER MFG. ERECTION GUIDES. AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. CUSTOKIER. DATE: 5/11/2016 R DRAWING INDEX DRAWING TITLE COVE=R SHEET NOTES ANCHOR ROD PLAN PRIMARY STRUCTURAL SECONDARY STRUCTURAL COVERING SPECIAL DRAWINGS STANDARD ERECTION DETAILS PLANOGRAPH DETAILS PAGES II 1 2.3 4 5-14 15-21 PERMIT DRAWINGS DRAWING RELEASE HISTORY TYPE DATE I DESCRIPTION 5/11/2016 1 PERMIT SET- For Building Dept. Approval GENERAL NOTES MATERIALS ASTM DESIGNATION 3 PLATE WELDED SECTIONS A529, A572, A1011, A1018 GRADE 55 COLD FORMED LIGHT GAGE SHAPES A653, A1011 GRADE 60 BRACE RODS A572, A510 GRADE 50 HOT ROLLED MILL SHAPES A36, A529, A572, A588, A992 GRADE 36 OR 50 HOT ROLLED ANGLES A529, A572, A588, A992 GRADE 50 HOLLOW STRUCTURAL SECTION (HSS) A500 GRADE B CLADDING A653, A792 GRADE 50 OR GRADE 80 HIGH STRENGTH BOLT TIGHTENING REQUIREMENTS IT IS THE RESPONSIBILITY OF THE ERECTOR TO ENSURE PROPER BOLT TIGHTNESS IN ACCORDANCE WITH APPLICABLE REGULATIONS. SEE RCSC SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH STRENGTH BOLTS FOR MORE INFORMATION. SEE ERECTION GUIDE FOR BOLT TIGHTENING INSTRUCTIONS. THE FOLLOWING CRITERIA MAY BE USED TO DETERMINE THE BOLT TIGHTNESS (I.E.-SNUG TIGHT OR PRE -TENSION) UNLESS REQUIRED OTHERWISE BY LOCAL JURISDICTION OR CONTRACT. ALL A490 BOLTS SHALL BE "PRE -TENSIONED". A325 BOLTS IN PRIMARY FRAMING AND BRACING CONNECTIONS MAY BE "SNUG -TIGHT" EXCEPT AS FOLLOWS; PRE -TENSION A325 BOLTS IF BUILDING SUPPORTS A CRANE GREATER THAN 5 TON CAPACITY. PRE -TENSION A325 BOLTS IF BUILDING SUPPORTS MACHINERY THAT CREATES VIBRATION, IMPACT, OR STRESS REVERSALS ON CONNECTIONS. PRE -TENSION A325 BOLTS IF LOCATED IN HIGH SEISMIC AREAS. FOR IBC BASED CODES; HIGH SEISMIC IS DESIGN CATEGORY D, E OR F. SEE CODES AND LOADS SECTION BELOW FOR DETAILS. PRE -TENSION ANY CONNECTION WITH DESIGNATION A325 -SC. SLIP CRITICAL (SC) CONNECTIONS MUST BE FREE OF PAINT, OIL OR OTHER MATERIALS THAT REDUCE FRICTION AT CONTACT SURFACES. GALVANIZED OR LIGHTLY RUSTED SURFACES ARE ACCEPTABLE. IN CANADA, ALL A325 AND A490 BOLTS SHALL BE "PRE -TENSIONED', EXCEPT FOR SECONDARY MEMBERS AND FLANGE BRACES. SECONDARY MEMBERS AND FLANGE BRACE CONNECTIONS ARE ALWAYS "SNUG TIGHT-, UNLESS INDICATED OTHERWISE IN ERECTION DRAWING DETAILS. B U TTE COUNTY JUN @ 9' 2016 DEVELOPMENT SERVICE 0) & - I -�,9A r— �jvs, t�`...J `-J L cn ! � = C67794 asl C/V 11- ��\P FBF CAL1F0 VPC PLEN-WE Wf ,,,1721-01 B �� _ �= BUILDING 4 1 "a p( [ .� t33y{{ E '•�a. A THE BUTLER MFG. ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF BUTLER MFG. AND DESIGN AND PERFORIv1ANCE REQUIREMENTS SPECIFIED BY BUTLER. THE BUTLER MFG. ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY BUTLER EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY BUTLER. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF BUTLER MFG. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF BUTLER MFG.JOBt BUTLER MANUFACTURING 1540 GENESSEE ST. KANSAS CITY, MO 64102 COVER SHEET _... __._ BULOER North Valley Building Systems, Inc. BUTLER Butler Manufacturin 9 VPCVERSION 2016.1 of BlueSeope Buildngs North Amerlea, Inc. 16-008721-01 THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING. DETAILS REFERENCED IN THIS DRAWING. ALL APPLICABLE BUTLER MFG. ERECTION GUIDES. AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. CUSTOKIER. DATE: 5/11/2016 LOCATON Chico, California oRAwr,cIIECK RFG PROSECT. Gig 7 Crop Insurance PAGE: GE: 1 BtERSPor t division VPC PLEN-WE Wf ,,,1721-01 B �� _ �= BUILDING 4 1 "a p( [ .� t33y{{ E '•�a. A t � i - _ _- -.._ ._ _... .w..__...._... m rn rn 71 71 p . Frame Member Schedule Part Mem Width Thick CX003 1 5.0000 .2500 RBX004 2 5.0000 .3125 1/2" 3 5.0000 .1875 RBX005 4 5.0000 .1875 5 5.0000 .3125 CX004 6 5.0000 .2500 8 28'-10" Ridge Ht. 7 1'-0" 6 4'-6" 5 2 @ 4'-1" 4 l'-1 1/8" 3 3'-6" 2 4'-0" 1 8 1/2" Dimension Key WebThk. Depthl .1345 1'-0" .1345 1'-8" .1345 1'-6" .1345 9" .1345 1'-6" .1345 1'-0" (2)GFB3000 Depth2 2'-2" 11-611 '-6" 911 11-61, '-6" 1'-8" 2'-2" co 0 N ITi W C7 � i W GFB20811 I I I I i I Approx.Lgth 18'-0 5/16" 31'-9 1/16" Approx.Weight 375# 476# 31'-9 1/16" 476# 18'-0 5/16" 375# 12 ok11,5% 0 LO 0 N � � CD i W i i i � O Frame Clearances Horiz. Clearance between members l(CX003) and 6(CX004): 59'-2 11/16" Vert. Clearance at member 1(CX003): 16'-5" Vert. Clearance at member 6(CX004): 16'-5" Finished Floor Elevation = 100'-0" (Unless Noted Otherwise) Bolt Connection & Plate Schedule Id Qty Grade Bolt Bolt Plate Rows Rows Washer PartNo Dia. Length Thick. Out In A 5 A325 3/4" 2 1/2" 1/2" 2 3 Yes 0097284 B 4 A325 3/4" 2 1/2" 3/8" 1 1 Yes 0097284 N N M MS @ S'. Q 13 M rn p., Q, �0 W w 0 B C) � � W � W a � � R 65'-0" FRAME CROSS SECTION AT FRAME LINES) 2 Shape Name = Unit 1 - Building Wali 4, Frame 2 00 0 N W isr 0 11 I I I I I I I 1(2)GFB3000 JGFB2081 I I I I I 3 �1� G I c7 C 6779)4'+''�� r2, CAL 1. USE 1/2 X 1 1/2 A325 -N BOLT (49080) AND NUT (47120) THE BUTLER MFG. ENGINEER'S SEAL APPLIES THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY BUTLER MANUFACTURING W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS, ONLY TO THE WORK PRODUCT OF BUTLER OF BUTLER MFG. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED 1540 GENESSEE ST. KANSAS CITY, MO 64102 FRAME CROSS SECTION AT FRAME LINE(S) 2 SECONDARY CLIP CONNECTIONS, AND FLANGE BRACE CONNECTIONS, MFG, AND DESIGN AND PERFORMANCE IN THE APPLICABLE PURCHASE ORDER AND SHALL NOT BE MODIFIED, REPRODUCED OR UNLESS NOTED OTHERWISE. REQUIREMENTS SPECIFIED BY BUTLER. USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF BUTLER MFG. J013 t. 2. SLOT REINFORCEMENT PLATES NEED NOT BE LOCATED ON THE SAME THE BUTLER MFG. ENGINEER'S SEAL DOES REV. OATS BY: DESCRIPTION: BUILDER: North Valle/ Building Systems, Inc. 16-008721-01 THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR SIDE OF THE WEB AS THE HILLSIDE WASHER. NOT APPLY TO THE PERFORMANCE OR CUSTOMER: DATE: DESIGN OF ANY OTHER PRODUCT OR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN BUTLER 5/11/2016 COMPONENT FURNISHED BY BUTLER EXCEPT ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL LOCATION: Chico, lif Caorna i oRAwwcr+ECK TO ANY DESIGN OR PERFORMANCE APPLICABLE BUTLER MFG. ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING PROJECT: Gig7 Crop Insurance P Butler Manufacturing JLD / RFG DRAVNNGSCALE: NTS PAGE: 7 REQUIREMENTS SPECIFIED BY BUTLER. TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. BUILDER'S PON VPCVERSION: 2016.1 VPC F LENAME- 16-008721.01 5112018 15.40:56 a dviaion of BlueSoope Widir pe North Artnrlca. Inc. f--, .••. � . . x , . - .. � ray 12 VPC FILENAME: 16,r,08721-01 oil lUvio Frame Member Schedule Part Mem Width Thick CX007 1 5.0000 .2500 RBX006 2 5.0000 .3125 De th2 3 5.0000 .1875 RBX007 4 5.0000 .1875 2'-2" 5 5.0000 .3125 CX008 6 5.0000 .2500 6 28'-10” Ridge Ht. 5 11-0" 4 4'-6" 3 2 @ 4'-1" 2 1'-1 1/8" 1 8 1/2" Dimension Key T (2)GFB3000 GFB2083 1. USE 1/2 X 1 1/2 A325 -N BOLT (49080) AND NUT (47120) W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS, SECONDARY CLIP CONNECTIONS, AND FLANGE BRACE CONNECTIONS, UNLESS NOTED OTHERWISE. 2. SLOT REINFORCEMENT PLATES NEED NOT BE LOCATED ON THE SAME SIDE OF THE WEB AS THE HILLSIDE WASHER. VPC FILENAME: moce721-01 oW-1 a 11-6„ —5 0 in C. N � i i i i N N0 5 1 I /8 ,I PO w 9. 000 B o o � � N � ` W � W \ � M � � o co �� �` o w � THE BUTLER MFG. ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF BUTLER MFG. AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY BUTLER. THE BUTLER MFG. ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY BUTLER EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY BUTLER. 65'-0" FRAME CROSS SECTION AT FRAME LINES) 4 Shape Name = Unit 1 - Building Wail 4, Frame 4 THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF BUTLER MFG. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF BUTLER MFG. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE BUTLER MFG. ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. BUTLER MANUFACTURING 1540 GENESSEE ST. KANSAS CITY, MO 64102 [2)GFB3000 GFB2081 It ko I C 6J14 C ``�IFCF CNL�F�� FRAME CROSS SECTION AT FRAME LINE(S) 4 REV. DATE BY: DESCRIPTION: ICER: North Valley Building Systems, Inc. CUSTOMER: LOCATION: Chico, California PROJECT: Gig 7 Crop Insurance DRAWNG SCALE: NTS BULDER'S POK 16-008721-01 DATE: BUTLER 5/1112016 ORAIM�YCHECIC Butler PAl.3E: Manufacturing JLD / RFG VPC VERSION: 216.1 9 a dvislon of BlueScope SLACInps North America, Inc. Frame Clearances WebThk. De thl De th2 APprox.L th APProx.Wei ht Horiz. Clearance between members l(CX007) and 6(CX008): 59'-2 11/16" .1345 1'-0" 2'-2" 18'-0 5/16" 374# Vert. Clearance at member 1(CX007): 16'-5" .1345 1'-8" 1'-6" 31'-9 1/16" 476# Vert. Clearance at member 6(CX008): 16'-5" .1345 1'-6" 9" Finished Floor Elevation = 100'-0" (Unless Noted Otherwise) .1345 9" 1'-6" 31'-9 1/16" 476# .1345 1'-6" 1'-8" .1345 1'-0" 2'-2" 18'-0 5/16" 375# OBolt Connection & Plate Schedule Id Qty Grade Bolt Bolt Plate Rows Rows Washer PartNo Dia. Length Thick. Out In A 5 A325 3/4" 2 1/2" 1/2" 3 2 Yes 0097284 B 4 A325 3/4" 2 1/2" 3/8" 1 1 Yes 0097284 C 4 A325 3/4" 2 1/2" 1/2" 2 2 Yes 0097284 T (2)GFB3000 GFB2083 1. USE 1/2 X 1 1/2 A325 -N BOLT (49080) AND NUT (47120) W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS, SECONDARY CLIP CONNECTIONS, AND FLANGE BRACE CONNECTIONS, UNLESS NOTED OTHERWISE. 2. SLOT REINFORCEMENT PLATES NEED NOT BE LOCATED ON THE SAME SIDE OF THE WEB AS THE HILLSIDE WASHER. VPC FILENAME: moce721-01 oW-1 a 11-6„ —5 0 in C. N � i i i i N N0 5 1 I /8 ,I PO w 9. 000 B o o � � N � ` W � W \ � M � � o co �� �` o w � THE BUTLER MFG. ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF BUTLER MFG. AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY BUTLER. THE BUTLER MFG. ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY BUTLER EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY BUTLER. 65'-0" FRAME CROSS SECTION AT FRAME LINES) 4 Shape Name = Unit 1 - Building Wail 4, Frame 4 THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF BUTLER MFG. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF BUTLER MFG. THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE BUTLER MFG. ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. BUTLER MANUFACTURING 1540 GENESSEE ST. KANSAS CITY, MO 64102 [2)GFB3000 GFB2081 It ko I C 6J14 C ``�IFCF CNL�F�� FRAME CROSS SECTION AT FRAME LINE(S) 4 REV. DATE BY: DESCRIPTION: ICER: North Valley Building Systems, Inc. CUSTOMER: LOCATION: Chico, California PROJECT: Gig 7 Crop Insurance DRAWNG SCALE: NTS BULDER'S POK 16-008721-01 DATE: BUTLER 5/1112016 ORAIM�YCHECIC Butler PAl.3E: Manufacturing JLD / RFG VPC VERSION: 216.1 9 a dvislon of BlueScope SLACInps North America, Inc. Frame Member Schedule BUTLER MANUFACTURING 1, USE 1/2 X 1 1/2 A325 -N BOLT (49080) AND NUT (47120) ONLY TO THE WORK PRODUCT OF BUTLER OF BUTLER MFG. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED 1540 GENESSEE ST. KANSAS CITY, MO 64102 FRAME CROSS SECTION AT FRAME LINE(S) 5 W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS, MFG. AND DESIGN AND PERFORMANCE IN THE APPLICABLE PURCHASE ORDER AND SHALL NOT BE MODIFIED, REPRODUCED OR Part Mem Width Thick WebThk. Depthl Depth2 Approx.Lgth BULDER: North Valley Building Systems, Inc. nc. Approx.Weight Frame Clearances UNLESS NOTED OTHERWISE. THE BUTLER MFG. ENGINEER'S SEAL DOES CX009 1 5.0000 .2500 .1345 1'-0" 2'-2" 18'-0 5/16" 374# Horiz. Clearance between members l(CX009) and 6(CX008): 59'-2 11/16" RBX007 2 5.0000 .3125 .1345 1'-8" 1'-6" 31'-9 5/11/2016 1/16" 476# Vert. Clearance at member l(CX009): 16'-5" COMPONENT FURNISHED BY BUTLER EXCEPT ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL DRAVMYCHECK JLD RFG Vert. Clearance at member 6(CX008): 16'-5" TO ANY DESIGN OR PERFORMANCE APPLICABLE BUTLER MFG. ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING 3 5.0000 .1875 .1345 1'-6" 9" DRAWING SCALE: NTS SPECIFIED BY BUTLER. TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. BUPO* BUILDER'S VPCVERSION: 2016.1 N Ci, ..C....... 0.04- Al- A -d - Irv. r:REQUIREMENTS 10 Finished Floor Elevation = 100'-0" (Unless Noted Otherwise) RBX007 4 5.0000 .1875 1345 .' 9" 1-6" 31'-9 1/16" 476# 5 5.0000 .3125 .1345 1'-6" 1'-8" CX008 6 5.0000 .2500 .1345 1'-0" 2'-2" 18'-0 5/16" 375# L OBolt Connection & Plate Schedule Id Qty Grade Bolt Bolt Plate Rows Rows Washer PartNo Dia. Length Thick. Out In A 4 A325 3/4" 2 1/2" 1/2" 2 2 Yes 0097284 B 4 A325 3/4" 2 1/2" 3/8" 1 1 Yes 0097284 T (2)GFB3000 6 28'-10" Ridge Ht. 5 1'-0" 4 4'-6" 3 2 @ 4'-1" 2 1'-1 1/8" 1 8 1/2" Dimension Key OCJQ .I 5' _\j O 0 O W � W L9 i i i i i i i r 11- M M M O o N N M m W W O L0 O � N � � W 34''3 L° 5, Z/8►, 00, 4 w i C7 OD 00 O O W 65'-0" FRAME CROSS SECTION AT FRAME LINES) 5 Shape Name = Unit 1 - Building Wall 4, Frame 6 1(2)GFB3000 VPC FILENAME'. j&c,G8721-ct r7. THE BUTLER MFG. ENGINEER'S SEAL APPLIES THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY BUTLER MANUFACTURING 1, USE 1/2 X 1 1/2 A325 -N BOLT (49080) AND NUT (47120) ONLY TO THE WORK PRODUCT OF BUTLER OF BUTLER MFG. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED 1540 GENESSEE ST. KANSAS CITY, MO 64102 FRAME CROSS SECTION AT FRAME LINE(S) 5 W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS, MFG. AND DESIGN AND PERFORMANCE IN THE APPLICABLE PURCHASE ORDER AND SHALL NOT BE MODIFIED, REPRODUCED OR SECONDARY CLIP CONNECTIONS, AND FLANGE BRACE CONNECTIONS, REQUIREMENTS SPECIFIED BY BUTLER. USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF BUTLER MFG. REv. C Te Bv: DESCRIPTION: BULDER: North Valley Building Systems, Inc. nc. -008721-01 UNLESS NOTED OTHERWISE. THE BUTLER MFG. ENGINEER'S SEAL DOES 166- THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR sore 2. SLOT REINFORCEMENT PLATES NEED NOT BE LOCATED ON THE SAME NOT APPLY TO THE PERFORMANCE OR CUSTOMER: SIDE OF THE WEB AS THE HILLSIDE WASHER. DESIGN OF ANY OTHER PRODUCT OR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN LOCATION: Chico, California BUTLER 5/11/2016 COMPONENT FURNISHED BY BUTLER EXCEPT ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL DRAVMYCHECK JLD RFG TO ANY DESIGN OR PERFORMANCE APPLICABLE BUTLER MFG. ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING PROJECT: Gig 7 Crop Insurance Manufacturing Butler Manufacturin DRAWING SCALE: NTS SPECIFIED BY BUTLER. TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. BUPO* BUILDER'S VPCVERSION: 2016.1 N Ci, ..C....... 0.04- Al- A -d - Irv. r:REQUIREMENTS 10 VPC FILENAME'. j&c,G8721-ct r7. • VPC FLEt"L 1&�8721-o1 511 ir201e 15 41:02 ROD SLOT BACKING PLATE MAY EXIST HARDWARE INSTALL IN THIS ORDER: H,LLSiDE WASHER FLAT WASHER "B" FLAT WASHER "A" HCX NUT WALL BRACE ROD REV. DAT -05/10/10 REV. NO 01 ROD BRACING THRU ROD SLOT BR02H1 COLUMN SHOWN / RAFTER SIMILAR —10*0 0 0— CLIP REQ'D W1 THICK FLANGES 0 ALTERNATE CONNECTIONS BRACE ¢ FRMS BRACE LOCATION I LOCATION - ROOF NOTE: ALL BOLTS TO BE SECONDARY 1/2" X 1 1/2" A325 MEMBER BOLTS (49080) (U.N.O.) FLANGE BRACE (CFS-) OR (HFB-) FLANGE BRACE WILL TYPICALLY CONNECT TO THE WEB OF THE FRAME MEMBER. 1/2" X 1 1/2" A325 BOLTS (49080) WITH HARDENED WASHER (095872) EACH SIDE (TYP AT PURLIN END OF BRACE) 1-11� FLANGE BRACE REQUIREM--NTS: RULE#1- ALL FLANGE BRACES ON CROSS SECTIONS MUST BE INSTALLED. RULE#2- SINGLE FLANGE BRACES ARE REQUIRED WHEN PART MARK ON CROSS SECTION IS NOT ACCOMPANIED BY (2). ENDPOST RULE#3- FLANGE BRACES ARE REQUIRED BOTH SIDES OF THE FRAME WEB WHEN PART MARK IS ACCOMPANIED BY (2). RULE#4- WHENEVER POSSIBLE, PLACE SINGLE BRACES TOWARD THE CENTER OF THE BUILDING. RULE#5- WHENEVER POSSIBLE, PLACE ALL SINGLE BRACES ON THE SAME SIDE OF THE FRAME WEB. '1* 10" & 11 1/2" PURLINS REQUIRE 3 BOLTS AT EACH END OF PURLIN LAP. REV. OATE.07/01/DgRE'. NO.001 TYPICAL FLANGE BRACE CONNECTIONS REV. DATE:06/14/11 IRLY NO. 01 BR06AE CONT. PURLIN LAP SHOWN, CONT. GIRT & SIMPLE PURLIN I BR25A3 PURLIN FLANGE BRACE (GFB— OR HFB—) F FEET G = GAGE CX*** = COLUMN (PLATE) WASHERS CGX*** — ROLA DIA. NUT A B HILLSIDE 3/8. 095321 09640B 46040 043657 1/2" 095230 095872 095946 043657 5/8" 095233 095945 095946 043657 3/4' 095235 095946 095948 043658 7/13" 095237 095947 095948 043658 1" 095238 095948 095949 043659 1 1/8" 095239 095949 095949 043659 REV. DAT -05/10/10 REV. NO 01 ROD BRACING THRU ROD SLOT BR02H1 COLUMN SHOWN / RAFTER SIMILAR —10*0 0 0— CLIP REQ'D W1 THICK FLANGES 0 ALTERNATE CONNECTIONS BRACE ¢ FRMS BRACE LOCATION I LOCATION - ROOF NOTE: ALL BOLTS TO BE SECONDARY 1/2" X 1 1/2" A325 MEMBER BOLTS (49080) (U.N.O.) FLANGE BRACE (CFS-) OR (HFB-) FLANGE BRACE WILL TYPICALLY CONNECT TO THE WEB OF THE FRAME MEMBER. 1/2" X 1 1/2" A325 BOLTS (49080) WITH HARDENED WASHER (095872) EACH SIDE (TYP AT PURLIN END OF BRACE) 1-11� FLANGE BRACE REQUIREM--NTS: RULE#1- ALL FLANGE BRACES ON CROSS SECTIONS MUST BE INSTALLED. RULE#2- SINGLE FLANGE BRACES ARE REQUIRED WHEN PART MARK ON CROSS SECTION IS NOT ACCOMPANIED BY (2). ENDPOST RULE#3- FLANGE BRACES ARE REQUIRED BOTH SIDES OF THE FRAME WEB WHEN PART MARK IS ACCOMPANIED BY (2). RULE#4- WHENEVER POSSIBLE, PLACE SINGLE BRACES TOWARD THE CENTER OF THE BUILDING. RULE#5- WHENEVER POSSIBLE, PLACE ALL SINGLE BRACES ON THE SAME SIDE OF THE FRAME WEB. '1* 10" & 11 1/2" PURLINS REQUIRE 3 BOLTS AT EACH END OF PURLIN LAP. REV. OATE.07/01/DgRE'. NO.001 TYPICAL FLANGE BRACE CONNECTIONS REV. DATE:06/14/11 IRLY NO. 01 BR06AE CONT. PURLIN LAP SHOWN, CONT. GIRT & SIMPLE PURLIN I BR25A3 PURLIN FLANGE BRACE (GFB— OR HFB—) F FEET G = GAGE CX*** = COLUMN (PLATE) I = INCHES 0 = OPERATION CGX*** — COLUMN (GAGE) E = EIGHTHS C = FIN/COLOR WCX*** = COLUMN (HOTROLL) PANEL/COVERING BUTLER Butler Manufacturing g VPCVERSION: 2016,1 of BlusScooa Buildnos North America, Ine. 16-008721-01 116- W 1 31 1 7 2 6 1 K T D RBX*** =RAFTER {PLATE) * F F I I E G G 0 C C C BGX*** s RAFTER (GAGE) LENGTH CODE WRX*** RAFTER (HOTROLL) TRX;** = TRUSS RAFTER INSULATION 1 B 1 3 0 1 0 3 6 0 3 0 W V ICX*** INTERIOR COLUMN •* F F F I I I I I I E C C PCX*** a PIPE COLUMN, LENGTH WIDTH THK CODE TCX44* = TUBE COLUMN SECONDARY (STANDARD) 0 B Z 1 9 1 1 4 1 7————— EPX*** = ENDPOST (PLATE) k k* F F I I E G G* * *** EGX*** a ENDPOST (GAGE) DEPTHLENGTH GAGE ADJUST.CODES SHAPE CBX*** = CANOPY (PLATE) SECONDARY (SPECIAL) CBX*** = PIGGYBACK CANOPY 00108Z1911417--- DCC*** = 8 1/2" GAGE POST • * •' ' • F F I I E GG' • COUNTER DEPTH& LENGTH GAGE ADJUST.CODES DCE*** = 10" GAGE POST SHAPE ROD BRACING RAKE J 0 3 R S 2 5 1 0 RS = THREADS BOTH ENDS BEAM I E * * F F I I RT = THREADS ONE END - CLEVIS ONE END DIA LENGTH RU = CLEVIS BOTH ENDS RP = THREAD BOTH ENDS — NO HILLSIDES BASIC ERECTION GUIDE REQUIRED FOR THIS PROJECT: REFER TO: WIDESPAN STRUCTURAL SYSTEM 2013 INSTALLATION GUIDE BUTLER m �RDATE!08/22/11TREV. N0. 01 REV. DA11:01/30/14 REV. NQ 00ENDPOST TOP BRACINGMARK NUMBER KEY BASIC ERECTION GUIDE - STRUCTURAL ENDPOST WITHIN 6" (152mrn) OF PURLIN EN50B1 COMMON GENERATED MARK NUMBERS ENB002 S 1. USE 1/2 X 1 1/2 A325 -N BOLT (49080) AND NUT (47120) W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS, SECONDARY CLIP CONNECTIONS, AND FLANGE BRACE CONNECTIONS, UNLESS NOTED OTHERWISE. 2. SLOT REINFORCEMENT PLATES NEED NOT BE LOCATED ON THE SAME SIDE OF THE WEB AS THE HILLSIDE WASHER. THE BUTLER MFG. ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF BUTLER MFG. AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY BUTLER. 7HE BUTLER MFG. ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY BUTLER EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY BUTLER. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF BUTLER MFG. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF BUTLER MFG. BUTLER MANUFACTURING 1540 GENESSEE ST. KANSAS CITY, MO 64102 PRIMARY BRACING SED'S REV: °Are BY: °EscR'Pr'°": BUILDER: North Valley Building Systems, Inc. CUSTOMER: LOCATION: Chico, California PROJECT: Gig 7 Crop Insurance BUILDER'S PO# a dvlaion BUTLER Butler Manufacturing g VPCVERSION: 2016,1 of BlusScooa Buildnos North America, Ine. 16-008721-01 116- THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE BUTLER MFG. ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. DATE: 5/11/2016 DRAvvrHECK RFG GE: PAGE: 1 13 r0ZIL NG SCALE: NTS VPC FILENAME 16-GG8721-01 "'*"GUSSETS WHEN REQUIRED BY DESIGN STITCH OR "*"GUSSETS WHEN REQUIRED BY DESI •• VV✓JLLJ YY lIIJ IV LN" VU 11\LJ✓ LL Ll L1 L-) 1171V N _ �-�- VLY •• VV VJLIV YY 11LL ♦,LJ �[V 11\LV ✓1 VL✓1TY P 1 1/2" — 3 (10 GA. WEB) CJP _ OR _� �_�� T Y P 2 — 5 (3/16 & 1/4 WEB) -------------------------------- ----------------- - =Y---, , j-� CJP ALTERNATE 4 — 8 (5/16 — 1/2 WEB) * �k BOLTING f PLATE f ROWS rROWS ' - `ROWS ROWS OUT I Al i OUT OUT OUT ,�--- f�---- TYP - ALTERNATE * -'""-- BOLTING V TYP PLATE OR ALTERNATE ROWS CJ BOLTING OR ROWS ROWS IN ALTERNATE PLATE ROWS ALTERNA E ALTERNATE CJP-! f_ f---- -"%% ,, IN f.- ' ' �� IN __ OR BOLTING i '' .-IN ---------- BOLTIN _ _- BOLTING - PLATE CJP •, / _ __ PLATE PLAT -----'"-- RID Rows; 'i- , oR ti F / RA TER �'�----- ' CJP CJP ; ,t OR Ci VSTITCH "-ROWS OUT CJP `•� ,1 1/2" — 3 (10 GA. WEB) STITCH % 2 — 5 (3/16 & 1/4 WEB) * �k OR 1 1/2" — 3 (10 GA. WEB) CJP `� * ALTERNATE CJP '�.. * Ci 2 — 5 (3/16 & 1/4 WEB) '� ;� BOLTING 4 — 8 (5/16 — 1/2 WEB) PLATE REV. DATE: 01113/14 REV. NO. 02 HAUNCH / COLUMN CONNECTION REV. DATE: 01113/14 REV. NO. OZ LOW SIDE HAUNCH CONNECTION REV. DATE: 01/13/14 REV. NO. OT HIGH SIDE CONNECTION REV. DATE: 01/13/14 REV. NO. O2 BOLTED RAFTER SPLICE CONNECTIONS TOP BOLTED WELD STD. FACE BOLTED WELD STD. BOLTED WELD STD. WELD STD. STITCH 1 1/2" — 3 (10 GA. WEB COLUMN (CX—) OR (IC COLUMN (TCX—) OR (PCX—) 2 — 5 (3/16 & 1/4 WE CJP 4 — 8 (5/16 — 1/2 WEB) ; i CJP j E FLANGE CHANGE i CONNECTION i SPLICE TU$E OR PIPE COLUMN t CJP STIFF. (S.W.) -----------� r------------------ —. i CJP BASE PLATE I I i j RANDOM SHOP SPLICE \rnn i BASE PLATE CJP TYP. CJP I_ DESIGN MEMBER DEPTH 1— REV. DATE: 2/23112 REV. NO. O1 FRAME CONNECTION AT INTERIOR COLUMN REV. DATE: 2/23/12 REV. NO. 01 TYPICAL BASE PLATE CONNECTION REV. DATE: 283112 REV. NO. 01 TYPICAL BASE PLATE CONNECTION REV. DATE: TR3/12 REV. NO. 01 VARIOUS RANDOM SHOP SPLICE WELD STD. BASE PLATE TO COLUMN WELD STD. BASE PLATE TO COLUMN WELD STD. SHOP SPLICE WELD STD. _ MINIMUM FILLET WELD FLUSH - UNSTIFFENED • The Table below Shows Code minimum welds for AISC & CSA/W59. If weld shown on Engineering Weld Standard or on fabrication LANGE PLAT GENERAL NOTES GENERAL NOTES: o o a o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o a 0 0 0 0 docurnellts are less than these, then the weld size shown below THE FILLET WELD SHALL BE CONTINUOUSLY 0 0 0 0 0 0 0 0 0 0 0 0 is to be used, based on the material thickness bei,lg joined. SUBMERGED ARC WELDED ONE SIDE OF THE 1. SEE FRAME CROSS SECTION FOR BOLTING PLATE o 0 0 0 0 0 0 0 AISC TABLE J2.4 & AWSD1.15.8 MINIMUMGMAWFILLET WELD SIZE WEB TO BOTH FLANGES AS ILLUSTRATED. WEB PLATE THE MINIMUM FILLET WELD SIZE SHALL BE THICKNESS AND NUMBER OF ROWS OUT AND IN. 0 0 0 0 f TAKEN FROM TABLE BELOW. 11 12 13 14 51 52 53 54 Minimum Size Base Metal Thickness (T)' of Fillet Weld 2. MIN. BOLTING PLATE WIDTH =FLANGE SIZE (6 " EXTENDED - UNSTIFFENED in. mm in. mm T<1/4 T<6 1/8 3 MIN.) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1/4<T<1/2 T<_12 3/16 5 _ MIN. Li 0 0 0 0 0 0 0 0 • 1/2<T<3/4_ 12<T<20 1/4 6 3- SIZE OF WELDS UNLESS NOTED ARE BASED ON O O O O MINIMUM FILLET WELD SIZES (USA, CANADA B, MEXICO) (AWSD1.1-TABLE5.8) ala <T 20 <T 5/16 8 MATERIAL THICKNESS FLANGETHICKNESS - ' T = Thickl;ess of the thinner part joined (USA, CANADA & MEXICO) WEB 3/16" THICKNECS OR OVER 114" 5/16" 318" 112" 5181 314" 1" 1 Ip" 1 114" 1 114" 31 32 33 71 72 73 - Assumes low hydrogen welding process using GMAW filler metal LESS EXTENDED -STIFFENED (GUSSET) 1oGA 1/a1 1/8" 118" 118" 118" 1/a" 118" 1111" 1/8" 118" 1/8" class ER70-3 (B-G49A 2C G3) or SAW filler metal class F7A0- SGA 118" 118- 1/8" 1/8" 1111" 118" 118" 1/8" 118" 118" 1/8" EF013K (F49A2-FM13K). 0 0 0 0 010 0 0 0 0 0 0 0 0 0 0 0 0 3116" 1/8" 1/8- Ile" 1/8" 1/8" 1181 118" v8" 3116" 3116" 3116" FILLET WELD ASSEMBLY (AWS D1.1-06 Sec 5.22.1) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 114" 1181 1/8" 1/6" 118" 118" 1/a" 118" 3116" 3/16" 3116" 3/161 o 0 0 0 0 0 0 0 Gaps In parts to be joined by fillet welds may have a s11s" Ire" 1/11" 3116"3/16" 3116" 3116" 3116" 3/16" 3/16" alts" 6116" gap of < 1/16" with no adjustment In weld size. O O O O 318" 118" 118" 3/16" 3116" 3116" 3116" 3116" 3/16" 3116" 3116" 3116" Gaps > 1/16" but < 3/16";fillet weld leg must be Increased 112" 118" 118' 3/16" 3116" 3/16" 3/16" 31161 3116" 3116" 3/16" 3/16" by the amount of the root opening. 41 42 43 81 82 83 u6- 1/111 1/8" 3116" 3116" 3/16" 114" v4"1/a- v4" 114" 1/4" Gaps > 3/16", corrective work is required to bring parts Minimum bolt spacing Is 3" U.N.O. > 3la" 1/a" 118" 3116" 3116" 3/16" 1/4- 114" 5/16" F4 S16" 5/16" 5116- into acceptable contact SEE "BOLTED END-PLATE CONNECTION" SECTION OF DESIGN CALCULATION FOR PLATE ID FJ REV. DATE: 2/23/12 REV. NO. 01 GENERAL WELD REQUIREMENTS REV. DATE: 2/23/12 REV. NO. Ot TYPICAL NOTES REV. DATE: 2123/12 REV. NO. 01 GENERAL NOTES REV. DATE: 01/13/14 REV. NO. 03 BOLTED END-PLATE CONNECTION LAYOUT WELD STD. TYPICAL SECTION THRU BUILT-UP MEMBERS r— /o iz; ' ' l C '7794 Lr_ l 111 0 clvl�_ THE BUTLER MFG. ENGINEER'S SEAL APPLIES THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY BUTLER MANUFACTURING MRD50 DRAWING ONLY TO THE WORK PRODUCT OF BUTLER OF BUTLER MFG. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED 1540 GENESSEE ST. KANSAS CIN, MO 64102 MFG. AND DESIGN AND PERFORMANCE IN THE APPLICABLE PURCHASE ORDER AND SHALL NOT BE MODIFIED, REPRODUCED OR REV: DATE: BY: DESCRIPTION: BUILDER: North Valley Building Systems, Inc. OB 0 16-008721-01 116 - REQUIREMENTS SPECIFIED BY BUTLER. USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF BUTLER MFG. THE BUTLER MFG. ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR OF ANY OTHER PRODUCT OR CUSTOMER: Chico, California BUTLER THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN DATE 5/11 /2016 DRAWNICHECCHECK DESIGN LOCATION: • COMPONENT FURNISHED BY BUTLER EXCEPT ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL JLD / RFG TO ANY DESIGN OR PERFORMANCE APPLICABLE BUTLER MFG. ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING PROJECT: Gig 7 Crop Insurance Butler Manufacturing g PAGE: DRAWING SCALE: NTS REQUIREMENTS SPECIFIED BY BUTLER. TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY'BRACING. BUILDER'SPoa VPC VERSION: 2016.1 14= VPC FILENAME: 16-008721 01 i VPC FILENAME 16XJJ8721-01 ERECTION NOTE: BRACE i FRAXC BRACE OOF LOC.4iII LOCATION SEC,UNCARY WHEN A CHANNEL BRACE DOES NOT LINE UP W.TH ANOTHER MEMBER CHANNEL BRACE OR THE SLOTS IN THE PURLIN WEB FOR A DROP PIN CONNECTION BEND THE CHANNEL TABS TOWARD CHANNEL - NOTE: USE (1) 11/32" X 1 1/4" 1. SEE CHART FOR RIDGE BRACE NEST AND T-45 GRAY SCRUBOLT097352) SCRUBOLT NUT (097267 ASSEMBLY SELECTION. ROTATE HEAD OF SCRUBOLT TO 0•, --uI THE PURLIN WEB AND USE A SELF -DRILLER (55307) TO ATTACH. PURLIN BRACE \ 2. NEST CHANNELS TO ACHIEVE Iia (� 0 ALIGNS BE ON OUTSIDE OF 0 Z, 0 (CPB-)(TYP.) I USE DROP PISECURE. HOLES AND 1 HOLES EAVE STRUT 0 0 -�- 01 USED TO --------------- --- - (2) 1/4-14 x 1 1/4" SECTION SECURE FLANGE BR (2) 1/4-14 x 1 1/4" STRUCT. SCREWS WITH DROP (GFB-) ORI-FBE-) STRUCT. SCREWS (55307) (2) 1/4" x 6 1/4" PINS CLP REQ -0 W/ (55307) DROP PINS (097556) J THCK -I W/ FLANGE BRACE WILL TYPICALLY CONNECT TO TI -E WEB Of il£ I - FRAME MEMBER. CHANNEL CHANNEL BRACE BRACE (CPB-) IF (CPB-) USE (2) 1/2" GALV. HEX NUTS (47120) LOCATE 1) NUT ON EACH SIDE OF PURLIN USE TOP HOLE OF ANTI -ROLL CLIP IF PRESENT. _ AT EAVE STRUT BEND PBA TABS AND USE (2)11/32" X 1 1/4" T-45 GRAY SCRUBOLT (097352) AND SCRUBOLT NUT (097267) (HEAD OF SCRUBOLT TO BE ON OUTSIDE OF EAVE STRUT)- EAVE PURLIN SEE FACE OF BRACE ASSY. EAVE STRUT VIEW \ (PBA-) FOR TAB ATTACHMENT FACE OF EAVE STRUT BR06AE CONT. PURLIN LAP SHOWN, CONT. GIRT &E SIMPLE PURLIN NOTE: END FRAME INT. FRAME INT. FRAME INT. FRAME 1. SEE. CHART FOR RIDGE BRACE NEST AND END BAY INTERIOR BAY ASSEMBLY SELECTION. ROOTATE CHANELS 2. NEST CHANNELS TO ACHIEVE �� �:n TO ALIGN 1 PURLIN BRACE 0 ] O O 1 PURLIN BRACE 0 ] O O - 5" BETWEEN HOLES AND �HOLES CHANNEL CHA,:N'-L USE DROP PINS TO SECURE. CHANNEL PUR_IN BRACE USED TO (CPE.-)(TYP) vim+ SECTION SECURE (2) PURLIN BRACE ] ] 0 0 (2) 1/4" x 6 1/4" WITH DROP CHANNELS (2) PURLIN BRACE PINS (3) PURLIN BRACE CHANNELS o ] ] O j DROP PINS (097556) I CHANNELS ] ] ] O 4 PURLIN BRACE ] ] ] ] (4) PURLIN BRACE ] ] ] ] CHANNELS CHANNELS i1 TYPICAL I -,-I TYPICAL CLUSTER CLUSTER CHANNEL STANDARD NOTES: . STANDARD NOTES:' DEPTH RIDGE BRACE - PURLINS HAVE CLUSTERS OF 4 HOLES FOR ATTACHING PURLIN BRACES. - PURLINS HAVE CLUSTERS OF 4 HOLES FOR ATTACHING PURLIN BRACES. Q ASSEMBLY 07 = 7" (CPBR- THESE CLUSTERS ARE REPRESENTED BY ONE OF THE SYMBOLS BELOW: THESE CLUSTERS ARE REPRESENTED BY ONE OF THE SYMBOLS BELOW: 08 = 8 1/2" PURLIN E 0 - DO NOT INSTALL PURLIN BRACES AT THIS CLUSTER LOCATION. 0 - DO NOT INSTALL PURLIN BRACES AT THIS CLUSTER LOCATION, 10 = 10" RIpG " ] - INSTALL PURLIN BRACES AT THIS CLUSTER LOCATION, ] - INSTALL PURLIN BRACES AT THIS CLUSTER LOCATION. 1, _ ,1 1/2 / (i) 1/4" X 6 1/4" PURLIN SEE SECONDARY ROOF DRAWING FOR BRACE REQUIREMENTS. SEE SECONDARY ROOF DRAWING FOR BRACE REQUIREMENTS. DROP PIN (097556) - INSTALL PURLIN BRACES AT THE RIDGE AND WORK TOWARD THE EAVE. - INSTALL PURLIN BRACES AT THE RIDGE AND WORK TOWARD THE EAVE. (TYP. PER EACH END) - CHANNEL BRACE MAY BE LOCATED IN EITHER SET OF SLOTS IN CLUSTER - CHANNEL BRACE MAY BE LOCATED IN EITHER SET OF SLOTS IN CLUSTER PROVIDED THEY ARE ALIGNED FROM EAVE TO EAVE IN A GIVEN BAY, PROVIDED THEY ARE ALIGNED FROM EAVE TO EAVE IN A GNEN BAY. , . . REV. Wif:07 01 W REV, NO. 00 - "rVT[;07/Oj/O9IRFV. N0. 00 .Ev. D.,CD7/cl,, NLV No 0o SINGLE CHANNEL PURLIN BRACE KV WL -07/01/1>9"`" "O 0G CHANNEL RIDGE BRACE ASSEMBLY REVpATL:07/Ot9 IFVN000 PURLIN BRACE CLUSTER LOCATION PURLIN BRACE CLUSTER LOCATION BROSIPH INTERMEDIATE LOCATION BR09PK SINGLE BRACE AT SYI,IMETRICAL RIDGE BR09RY END BAY CHANNEL LOCATION BR09RZ INTERIOR BAY CHANNEL LOCATION EN5191 PG1 CLIP P01 CLIP PURLINPURLIN PURLIN WELDED CLIP CONNECTION EPC2 } EPC3 PU1RLN PC27 )a ARC1 ALT. CONNECTION d �, X15 ENDBAY e �' PUORLIN OF SECTION "A" SECTION "A" vPRlr5/ 1 1 * pi WELDED CLIP BOLTED CLIP L TT LE ADJUST. CODES GAGE EIGHTHS INCHESI LENGTH millimeters SHAPE TT ADJUST. CODES GAGE EIGHIH5 INCHE LENGTH EFFTI millimeters e,WADF SHAPE GAGE DEPTH SHAPE `-PURLIN pTSTRUT Z = ZEE 11 = 0.113 ALT[RNA?E CONNCCTgNS ZS=ZEE 11 =0.113 � 12=0.098 08 = 8 1/2' CS = CEE 12 = 0.098 E = LOW EAVE STRUT13 = OOBB . HANNELFLAN31 ES - LOW EAVE STRUT 13 - 0.0138 H - HIGH EAVE STRUT BRACE REQUIREMENTS: 11 = tt 1/2" �RIDGE BRACEPURLIN ASSEMBLY EAVE PURLIN BRACE EAVE PAGE: 16 RULEyt- ALL FLANGE BRACES ON CROSS SECTIDNS MUST BE INSTALLED. - BR09JG (CPBR-) � USE (2) 1/2" GALV. HEXDETAIL STRUT 15 = 0.073 RULEg2- SINGLE FLANGE BRACES ARE REQUIRED WHEN PART MARK ON FF = FACE TO FACE CEE EAVE STRUT (PBA-) AT 8 1/2 , 10", NUTS (47120) LOCATE (1CROSS 17 - 0.060 SECTION IS NOT ACCOMPANIED BY (2). I EBRACE STRAP11 1/2" PURLINS. NUT EACH SIDE OF PURLRULEh3- FLANGE BRACES ARE REQUIRED BOTH SIDES OF THE FRAME WEB (1) 1/4" X 6 1/4" RIp (ESBS1) AT 8 1/2%(NOT REQ. AT 7" PURLIN EAVE PURLINWHEN PART MARK IS ACCOMPANIED BY (2). DROP PIN 097556 () TO 7" EAVE STRUT) 10" 11 1/2" EAVE SRULEh4- BRACE ASSY.USE WHENEVER POSSIBLE, PLACE SINGLE BRACES TOWARD THE OF THE BUILDING. WHEN CHANNEL BRACE USE WHEN CHANNEL BRACE I DOES LINE UP WITH THE DpES NGT LINE UP WITH (TYP. PER EACH END) DETAIL BR09JG PURLIN (JCP051050) AT 7" PBA- TYP.CENTER PURLIN ( )( )RULEk5- WHENEVER POSSIBLE, PLACE ALL SINGLE BRACES ON THE SAME SLOTS IN THE PURLIN WEB. THE SLO S THE PURLIN WEB. T NOTE: SEE ERECTION DRAWINGS SIDE OF THE FRAME WEB. FOR LOCATION FOR LOW OR HIGH EAVE LOCATIONS. •• 10" &: 11 1/2' PURLINS REOUIRE 3 BOLTS AT EACH END OF PURLIN LAP. REV DATE 11/26/12 FEV. NO, 04 LAVE STRUT BRACE REV DAT[oI/o7/IS Rtv No 0. LAVE BRACE STRAP AND LAVE PURLIN BRACE LOCATED AT EAVE - CENTERLINE OF FRAME RC v. OAIE: G./ol/11 HLV. NO.D CHANNEL BRACE E-NDIN , AT PURLIN WEB SELF-DRILLE-R WITH BENT TABS REv D. rt: m/o1/w Atv No 0o TYPICAL FLANGE BRACE CONNECTIONS REr DAIL07/01/DG REv No 00 SINGLE CHANNEL PURLIN BRACE ENDING AT PURLIN µ'EB LOCATION NEV QAI[O7/01/� REV No OD CHANNEL RIDGE BRACE ASSEMBLY RIDGE BRACE ONLY AT SYMMETRICAL RIDGE BR09K2 BR09K5 BR09JG BR09JK BR09JH BR06AE CONT. PURLIN LAP SHOWN, CONT. GIRT &E SIMPLE PURLIN NOTE: END FRAME INT. FRAME INT. FRAME INT. FRAME 1. SEE. CHART FOR RIDGE BRACE NEST AND END BAY INTERIOR BAY ASSEMBLY SELECTION. ROOTATE CHANELS 2. NEST CHANNELS TO ACHIEVE �� �:n TO ALIGN 1 PURLIN BRACE 0 ] O O 1 PURLIN BRACE 0 ] O O - 5" BETWEEN HOLES AND �HOLES CHANNEL CHA,:N'-L USE DROP PINS TO SECURE. CHANNEL PUR_IN BRACE USED TO (CPE.-)(TYP) vim+ SECTION SECURE (2) PURLIN BRACE ] ] 0 0 (2) 1/4" x 6 1/4" WITH DROP CHANNELS (2) PURLIN BRACE PINS (3) PURLIN BRACE CHANNELS o ] ] O j DROP PINS (097556) I CHANNELS ] ] ] O 4 PURLIN BRACE ] ] ] ] (4) PURLIN BRACE ] ] ] ] CHANNELS CHANNELS i1 TYPICAL I -,-I TYPICAL CLUSTER CLUSTER CHANNEL STANDARD NOTES: . STANDARD NOTES:' DEPTH RIDGE BRACE - PURLINS HAVE CLUSTERS OF 4 HOLES FOR ATTACHING PURLIN BRACES. - PURLINS HAVE CLUSTERS OF 4 HOLES FOR ATTACHING PURLIN BRACES. Q ASSEMBLY 07 = 7" (CPBR- THESE CLUSTERS ARE REPRESENTED BY ONE OF THE SYMBOLS BELOW: THESE CLUSTERS ARE REPRESENTED BY ONE OF THE SYMBOLS BELOW: 08 = 8 1/2" PURLIN E 0 - DO NOT INSTALL PURLIN BRACES AT THIS CLUSTER LOCATION. 0 - DO NOT INSTALL PURLIN BRACES AT THIS CLUSTER LOCATION, 10 = 10" RIpG " ] - INSTALL PURLIN BRACES AT THIS CLUSTER LOCATION, ] - INSTALL PURLIN BRACES AT THIS CLUSTER LOCATION. 1, _ ,1 1/2 / (i) 1/4" X 6 1/4" PURLIN SEE SECONDARY ROOF DRAWING FOR BRACE REQUIREMENTS. SEE SECONDARY ROOF DRAWING FOR BRACE REQUIREMENTS. DROP PIN (097556) - INSTALL PURLIN BRACES AT THE RIDGE AND WORK TOWARD THE EAVE. - INSTALL PURLIN BRACES AT THE RIDGE AND WORK TOWARD THE EAVE. (TYP. PER EACH END) - CHANNEL BRACE MAY BE LOCATED IN EITHER SET OF SLOTS IN CLUSTER - CHANNEL BRACE MAY BE LOCATED IN EITHER SET OF SLOTS IN CLUSTER PROVIDED THEY ARE ALIGNED FROM EAVE TO EAVE IN A GIVEN BAY, PROVIDED THEY ARE ALIGNED FROM EAVE TO EAVE IN A GNEN BAY. , . . REV. Wif:07 01 W REV, NO. 00 - "rVT[;07/Oj/O9IRFV. N0. 00 .Ev. D.,CD7/cl,, NLV No 0o SINGLE CHANNEL PURLIN BRACE KV WL -07/01/1>9"`" "O 0G CHANNEL RIDGE BRACE ASSEMBLY REVpATL:07/Ot9 IFVN000 PURLIN BRACE CLUSTER LOCATION PURLIN BRACE CLUSTER LOCATION BROSIPH INTERMEDIATE LOCATION BR09PK SINGLE BRACE AT SYI,IMETRICAL RIDGE BR09RY END BAY CHANNEL LOCATION BR09RZ INTERIOR BAY CHANNEL LOCATION EN5191 PG1 CLIP P01 CLIP PURLINPURLIN PURLIN WELDED CLIP CONNECTION EPC2 } EPC3 PU1RLN PC27 )a ARC1 ALT. CONNECTION d �, X15 ENDBAY e �' PUORLIN OF SECTION "A" SECTION "A" vPRlr5/ 1 1 * pi WELDED CLIP BOLTED CLIP L TT LE ADJUST. CODES GAGE EIGHTHS INCHESI LENGTH millimeters SHAPE TT ADJUST. CODES GAGE EIGHIH5 INCHE LENGTH EFFTI millimeters e,WADF SHAPE GAGE DEPTH SHAPE GAGE Z = ZEE 11 = 0.113 07=7' ZS=ZEE 11 =0.113 C=CEE 12=0.098 08 = 8 1/2' CS = CEE 12 = 0.098 E = LOW EAVE STRUT13 = OOBB . 10 - 10' ES - LOW EAVE STRUT 13 - 0.0138 H - HIGH EAVE STRUT 14 = 0.079HS 11 = tt 1/2" - HIGH EAVE STRUT 14 = 0.079 15 0.073 PAGE: 16 BB = BACK TO BACK CEE 16 = 0.068 FB = FACE TO BACK CEE 15 = 0.073 FF = FACE TO FACE CEE 16 - 0.068 17 - 0.060 17 - 0.060 SECONDARY PART MARK NUMBER COMMON GENERATED MARK NUMBERS /(4) 1/2" A307 THIN HEAD BOLT (096636) & NUT (095032) /-EAVE STRUT WELDED CLIP CONNECTIONRP�(E BOLTED CLIP CONNECTION ��E PCE EAVE STRUT) ALT. COtar,ECT10N F ALT. CONNECTION BOLTED CLIP CONNECTION REFER TO ERECTION DRAWINGS fRPBPY LAVE STRUT BRACE STRAP- :A TRAP - i� ALT. C014NECT10N FOR ALL CLIP MARK NUMBERS (,E VARIES / ° AND LOCATIONS. SPP e (ESBS1) AT 8 1/2", 10", 43' f0 ;� CLIPS MAY BE REQUIRED FOR 8PY 11 1/2- PURLINS. USE LP 8O� PURLIN TO FRAME CONNECTIONS. (JCPO51050) AT 7' PURLINS. REFER TO INDIVIDUAL FRAME M PLATE _ CROSS SECTIONS FOR BOLTED °� SSEIE CHART b \ CLIP PART NUM3ERS AND THEIR A ( ) EN53F1 NOTE: EAP2 PLATE ONLY REO'D. WHEN CALLED OUT ON FRAME CROSS SECTION SHIM PLATE (SEE CHART)- PLATE HART)-PLATE (EAP2) SIDEWALL OR SOLDIER COLUMN -� PURLIN AND GIRT SIZES 8 112' 216mm SHIM PLATE ROOF PITCH RANGE PART NUMBER .25 TO 1.99 N/A 2.0 TO 2.49 N/A 2.5 TO 3,49 ESH1 3.5 TO 4,00 ESH2 ROOF BEAM 1 1% I /a/ REV DAR 06,117/IS IN RSO1 T1 EAVE STRU P'y0 RAKE BEAM -' 7' & 8 1/2" PURI -INS PURLIN CONNECTION AT INTERIOR FRAME REV °ATE 06/17/15 RE CONTINUOUS PURLINS RS02T1V. NO.m CC '1'-0' AT 7" h 8 1/2' OUTSET 1'-3" AT 10' & 11 1/2' OUTSET LOW EAVE STRUT SHOAN - HIGH EAVE STRUT SIMILAR ATE:w/26/15 R(V. No. 07 EAVE STRUT CONNECTION R512PH AT END FRAME -ATE PART NUMBER N/A ESDI ESH2 ESH3 ROOF BEAM 097280) Cb PURLIN CONNECTION TO END FRAME CONTINUOUS PURLINS 7" OR 8 1/2' PURLINS 0 ° 'N -RAFTER E:w/„/1A REV. NO a ANTI -ROLL PURLIN CLIPS RS03J1 WHEN REOUIRED BY DESIGN (2)1/2"X2" A325 BOLT (097280) - SHIM PLATE ROOF PITCH RANCE BOLT EAVE STRUT AND .25 TO 1.99 EAP2 PLATE TO FRAME W/ 2.0 TO 2.49 (v) 1/2" X 2" 2.5 TO 3.49 A325 BOLT (097280) 3.5 TO 4.00 / 4if off,f '1'-0" AT 7' & 8 1/2" OUTSET 1'-3" AT 10' & 11 1/2' OUTSET LORI EAVE STRUT SHOWN - HIGH EAVE STRUT USES SIMILAR PARIS. TL'o3/26/,5 IKLv. No.U2 EAVE STRUT W/ ATTACHMENT PLATE END FRAME RS12PF 1 1% I /a/ REV DAR 06,117/IS IN RSO1 T1 EAVE STRU P'y0 RAKE BEAM -' 7' & 8 1/2" PURI -INS PURLIN CONNECTION AT INTERIOR FRAME REV °ATE 06/17/15 RE CONTINUOUS PURLINS RS02T1V. NO.m CC '1'-0' AT 7" h 8 1/2' OUTSET 1'-3" AT 10' & 11 1/2' OUTSET LOW EAVE STRUT SHOAN - HIGH EAVE STRUT SIMILAR ATE:w/26/15 R(V. No. 07 EAVE STRUT CONNECTION R512PH AT END FRAME -ATE PART NUMBER N/A ESDI ESH2 ESH3 ROOF BEAM 097280) Cb PURLIN CONNECTION TO END FRAME CONTINUOUS PURLINS 7" OR 8 1/2' PURLINS 0 ° 'N -RAFTER E:w/„/1A REV. NO a ANTI -ROLL PURLIN CLIPS RS03J1 WHEN REOUIRED BY DESIGN (2)1/2"X2" A325 BOLT (097280) - SHIM PLATE ROOF PITCH RANCE PART NUMBER .25 TO 1.99 N/A 2.0 TO 2.49 ESHI 2.5 TO 3.49 ESH2 3.5 TO 4.00 ESH3 RS12PA FRAME OR SOLDIER COLUMN DATE. 07 of D I REV. No. oo SPECIAL SECONDARY PART MARK KEY EN 51 B2 COMMON GENERATED MARK NUMBERS EAVE STRUT (4) 1/2" A307 THIN LAVE STRUT HEAD BOLT (096636) BRACE STRAP At NUT (095032) (ESBS1) I A 0 1 SHIM PLATE , (SEE CHART) 1 I PLATE <1 ROOF BEAM SIDEWALL OR SOLDIER COLUMN SHIM PLATE EAVE STRUT AND EAPI PLATE TO FRAME W/ (8) 1 /2" X 2" I A325 BOLT (097280) ROOF PITCH PART RANGE NUMBERBOLT .25 TO 1.99 N/A 2.0 TO 2.49 NIA 2.5 TO 3.49 ESH1 3.5 TO 4.00ESH2 11 LOW EAVE STRUT SHOWN - HIGH EAVE STRUT USES SIMILAR PARTS. EAVE STRUT CONNECTION I AI DA7`03/'6/t8 REV. NO 0' EAVE STRUT W/ ATTACHMENT PLATE AT INTERIOR FRAME 11 RS12PE il INTERIOR FRAME 1. UNLESS NOTED, USE 1/2 X 1 1/2 A325 -N BOLT (49080) AND NUT (47120) W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS. 2. FLANGE BRACES ARE AN INTEGRAL PART OF THE STABILITY OF THE STRUCTURAL SYSTEM AND MUST BE PROPERLY INSTALLED PRIOR TO ERECTION OF WALL AND ROOF SHEETS. 3. REMOVAL OR ALTERATION OF ANY COMPONENT IS PROHIBITED. THE BUTLER MFG. ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF BUTLER MFG. AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY BUTLER. THE BUTLER MFG. ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY BUTLER EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY BUTLER. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF BUTLER MFG. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF BUTLER MFG. BUTLER MANUFACTURING 1540 GENESSEE ST. KANSAS CITY, MO 64102 ROOF SECONDARY SED'S REV: GATE BY: oescRIPTKNJ: BUILDER: North Valley Building Systems, Inc. CUSTOMER: LocATION California Chico, PROJECT: Gig 7 Crop Insurance BUILDER'S PC* ■ dvlsion BUTLER Butler Manufacturin 9 VPCVERSION: 2016.1 of BlueScope Builcings North Amedes, Ino. 16- 116OB - 008721-01 THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE BUTLER MFG. ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. OWTE: 5AVOIXH 16 DRAwwcHECK JLD / RFG PAGE: 16 DRAWNGSCALE: NTS VPC FILENAME 16-Gv8721.ol VPC FILE4WE 16-0 8721-01 5/112016 1541:11 I P. R Seccndary Part Schedule Mark Part Thick. Depth Detail G14 00908ZS191061310 0.0880 8 1/211 WSR001,WS01H2,WSR004 G15 01008ZS190921410 0.0790 8 1/211 WSR001,WS01H2,WSR004 G16 01108ZS160811510 0.0730 8 1/2" WSR001,WSO4E2,WS01H2 G17 08Z2009413EE10 0.0880 8 1/2" WS01H2 G5 00508ZS020911710 0.0600 8 1/211 WSR001,WSOlH2,WSO4E2 G7 08Z2009415EE10 0.0730 8 1/211 WS01H2 1 GFA300 Part Mark Key C C F� 2'-0" 21'-0" 22'-0" CL CL 65'-0" SECONDARY ELEVATION AT 6 Shape Name = Unit 1 - Building, Wali = 3 1 BL 1. UNLESS NOTED, USE 1/2 X 1 1/2 A325 -N BOLT (49080) AND NUT (47120) W/O WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS. 2. FLANGE BRACES ARE AN INTEGRAL PART OF THE STABILITY OF THE STRUCTURAL SYSTEM AND MUST BE PROPERLY INSTALLED PRIOR TO ERECTION OF WALL AND ROOF SHEETS. 3. REMOVAL OR ALTERATION OF ANY COMPONENT IS PROHIBITED. THE BUTLER MFG. ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF BUTLER MFG. AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY BUTLER. THE BUTLER MFG. ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY BUTLER EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY BUTLER. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF BUTLER MFG. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF BUTLER MFG. BUTLER MANUFACTURING 1540 GENESSEE ST. KANSAS CITY, MO 64102 SECONDARY ELEVATION AT 6 REV. DATE: BY: DESCRIPTION: ��: North Valley Building Systems, Inc. CUSTOMER: LOCATION: Chico, California PROJECT: Gig 7 Crop Insurance BULDER'sPar a dvieion BUTLER r. Butler Manufacturing Vf'CVERSION: 2016.1 of BlusSoope Buildnpe North Amedca, Inc. 1 16-008721-01 16- THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE BUTLER MFG. ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. DATE 5/11/2016 DRAvuNrcHECK JLD / RFG PACE: 19 DRAVVNcscr�: NTS VPC FILENAME: 16-wa721-ot ,' F Secondary Part Schedule Mark Part G18 08Z1911417BD00 G19 08Z2011417B100 G20 OBZ21114171100 3 3'-6" 2 4'-0" 1 6 11 Dimension Key Thick. Depth Lap Detail 0.0600 8 1/2" WSR001rWS01G2,WS01AV 0.0600 8 1/2" 10 1/2" WSR001,WS01G3 0.0600 8 1/2" 10 1/2" WSO1G3 I I I Bracing Part Schedule Part Qty Length 06RS2603 2 26'-3" Detail BROM ------------------------------ I _ I I I I I 065'2 I 60� ------------------------------- ------------------------------- -------------------------------- --------------- I I I j I I I i I I G19(Typ.) I I G20(Typ.) G20(Typ.) G20(Typ.) G19(Typ•) I I I i I I I I I I DAM 5/11/2016 5/1 I I G18 DRAIMHECK YC / RFG GE: PACE: 20 DRAWNCSCAI: NTS I OrO4 I I I . _ .... s dvielon of BlueSmoe BuBdnoe North Amerloa. Inc. I I I I BL i L 19'-61, - 20'-011 �. 20'-0" 20'-0" � 19'-6" CL CL CL CL 100'-0" SECONDARY ELEVATION AT D Shape Name = Unit 1 - Building, Wall = 4 A I BL 1. UNLESS NOTED, USE 1/2 X 1 1/2 A325 -N BOLT (49080) AND NUT (47120) W/0 WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS. 2. FLANGE GRACES ARE AN INTEGRAL PART OF THE STABILITY OF THE STRUCTURAL SYSTEM AND MUST BE PROPERLY INSTALLED PRIOR TO ERECTION OF OV AND ROOF SHEETS.AL OR ALTERATION OF ANY COMPONENT IS PROHIBITED. 3. REMOVAL THE BUTLER MFG. ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF BUTLER MFG. AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY BUTLER. THE BUTLER MFG. ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPONENT FURNISHED BY BUTLER EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY BUTLER. THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY OF BUTLER MFG. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED IN THE APPLICABLE PURCHASE ORDER AND SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF BUTLER MFG. BUTLER MANUFACTURING 1540 GENESSEE ST. KANSAS CITY, MO 64102 SECONDARY ELEVATION AT D REV. DATE BY: DESCRIPTION BLALDER: North Valley Building Systems, Inc �TO""� LOCATION: Chico, California PROJECT: Gig 7 Crop Insurance BUILDER'S PO* BUTLER Butler Manufacturin g \PCVERs'ON 2016,1 JOB. 16--008721-01 THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE BUTLER MFG. ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. DAM 5/11/2016 5/1 DRAIMHECK YC / RFG GE: PACE: 20 DRAWNCSCAI: NTS . _ .... s dvielon of BlueSmoe BuBdnoe North Amerloa. Inc. VPC FILENAME16008721-01 4 ^� 0 r ROD SLOT BACKING PLATE MAY EXIST HARDWARE INSTALL IN THIS ORDER: HILLSIDE WASHER FLAT WASHER "B" FLAT WASHER "A" HEX NJT BRACE E FRAME BRACE ROOF LOCATION LOCATION SECONDARY WALL BRACE MEMBER ROD BR02N1 WSO -, G2 ROD BRACING THRU ROD SLOT COLUMN SHOWN / RAFTER SIMILAR r 0 1-7' & 8 1/2" GIRT CLIP (PG1) 10` & 1 1 112" GIRT CLIP (CCD-) MAY BE SHOP ZEE GIRT SHOWN WELDED (GCI OR GCA-) CEE GIRT SIMILAR GIRT CONN. AT COLUMN OUTSET SIMPLE GIRTS CRT TO JAMS DEPTH 01 WASFIERS 7' 8 1/2" RCD DIA. NUT A B HILLSIDE -5/6, 095321 096408 46040 043657 ES - LOW EAVE STRUT 2" 095230 095872 095946 043657 V8. 095233 095945 095946 043657 3/4* = 16 = 0.068 095235 095946 095948 043658 FLANGE BRACE WILL TYPICALLY 095237 095947 095948 043658 —7Z6" 1' 095238 095948 095949 043659 1 1 ;" 095239 095949 095949 1 043659 BR02N1 WSO -, G2 ROD BRACING THRU ROD SLOT COLUMN SHOWN / RAFTER SIMILAR r 0 1-7' & 8 1/2" GIRT CLIP (PG1) 10` & 1 1 112" GIRT CLIP (CCD-) MAY BE SHOP ZEE GIRT SHOWN WELDED (GCI OR GCA-) CEE GIRT SIMILAR GIRT CONN. AT COLUMN OUTSET SIMPLE GIRTS CRT TO JAMS DEPTH 01 JAMB CLIP 7' 8 1/2" 1D" 11 1/2- = 7" JTG3 JTG6 12=0.098 08 = 8 1/2" 0 0 8 1/2' JTGI JTG5 JTG7 ES - LOW EAVE STRUT 10" ( j JTG4 JTG2 u 11 1/2" 15 = 0.073 JTG2 (2) 1/2" X I A325 BOLT (4! DIM. A O to A SINGLE JAMB 3 1/4" AT 7", 8 1/2-. 10" JAMB 6 1/4" AT 11 1/2' JAMB I WS20F2 (2) 1/2" A307 THIN HEAD BOLT (096636) & NUT (095032) GIRT CLIP (SEE CHART) .JWN CEE GIRT SIMILAR JAMB CAN BE 1 1/2' DEEPER THAN THE JAMB SUPPORT GIRT. (ONLY EXCEPTION' 11 1/2- JAMB CAN BE USED W/ 8 1/2' GIRT) ALICN JAMB AND GIRT AT BL GIRT TO JAMB SINGLE JAMB ALT.RNA1. C,�NNECTIUNS DEPTH FLAN,E BRACE REQUIREMENTS: 07 = 7 RILEb1- ALL FLANGE BRACES ON CROSS SECT104S MUST BE INSTALLED. 08 = 8 1/2" RULE#2- SINGLE FLANGE BRACES ARE REQUIRED &HEN PART MARK ON 10 = 10" CROSS SECTION IS NOT ACCOMPANIED BY (2). 11 = 11 1/2" RULEIJ3- FLANGE BRACES ARE REQU;RED EOOTH SIDES OF THE FRAME WEB WHEN PART MARK IS ACCO:.IPANII=D BY (2). R1LLE#-1- WHENEVER POSSIBLE, PLACE SINGLE BRACES TOWARD THE CENTER OF THE BUILDING, RULE,#5- WHENEVER POSSIBLE, PLACE ALL SINGLE BRACES ON THE SAME SIDE OF THE FRAME WEB. •• 10' a 11 1/2" PURLINS REQUIRE 3 LiOLTS AT EACH END OF PURLIN LAP. "E °""-°''°''°' ",, "° °" TYPICAL FLF�NGE BRACE CONNECTIONS REV. wiC:07/D1/09 R[V. N0. 00 BROCAE 11CONT. PURLIN LAP SHOWN, CONT. GIRT do SIMPLE PURLIN EN51 B 1 ZEE GIRT WS01 G3 HD,DER TO CLIP' (PCI) GDOR HEADER `A I I EQUAL 3" EQUAL rT_T i F70 I I I I I OPENING I I HEIGHT SECTION A -A WS20F9 yQ GIRT CLIP (PGI) MAY BE S )OP WELDED (CC1 OR GCA-) 7" & 8 1/2" GIRT GIRT CONN. AT COLUMN OUTSET CONTINUOUS GIRT 1. UNLESS NOTED, USE 1/2 X 1 1/2 A325 -N BOLT (49080) AND NUT (47120) W/0 WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS. 2. FLANGE BRACES ARE AN INTEGRAL PART OF THE STABILITY OF THE STRUCTURAL SYSTEM AND MUST BE PROPERLY INSTALLED PRIOR TO ERECTION OF Wi.LL AND ROOF SHEETS. 3. REMOVAL OR ALTERATION OF ANY COMPONENT IS PROHIBITED. SINGLE JAMB A307 THIN HEAD BOLT (096636) At NUT (095032) HEADE=R TC JAMB ANY HEADER, ANY SINGLE JAMB WS01H2 TT ADJUST. CODES GAGE EIGHTHS INCHINCHES1 LENGTH rrrI-millimeters ADJUST. CODES GAGE I HTH INCHES LENGTH rrrT millimeters SHAPE GAGE DEPTH 01 GAGE Z = ZEE 11 = 0.113 07=7' ZS=ZEE �— OI 12=0.098 08 = 8 1/2" CS =CEE 12 = 0.098 H - HIGH EAVE STRUT 0 0 10 - 10" ES - LOW EAVE STRUT 13 - 0.088 ( j 14 = 0.079HS 11 = 11 1/2" FLANC BRACE 14 = 0.079 15 = 0.073 (CFB- OR HFB-) BB =BACK TO BACK CEE CLIP RE�'J W/ = 16 = 0.068 FB - FACE TO BACK CEE THICK' FLAt4CLS FLANGE BRACE WILL TYPICALLY FF = FACE TO FACE CEE 16 - 0.068 CONNECT TO THE WEB OF THE v% FRAME MEMBER. ALT.RNA1. C,�NNECTIUNS DEPTH FLAN,E BRACE REQUIREMENTS: 07 = 7 RILEb1- ALL FLANGE BRACES ON CROSS SECT104S MUST BE INSTALLED. 08 = 8 1/2" RULE#2- SINGLE FLANGE BRACES ARE REQUIRED &HEN PART MARK ON 10 = 10" CROSS SECTION IS NOT ACCOMPANIED BY (2). 11 = 11 1/2" RULEIJ3- FLANGE BRACES ARE REQU;RED EOOTH SIDES OF THE FRAME WEB WHEN PART MARK IS ACCO:.IPANII=D BY (2). R1LLE#-1- WHENEVER POSSIBLE, PLACE SINGLE BRACES TOWARD THE CENTER OF THE BUILDING, RULE,#5- WHENEVER POSSIBLE, PLACE ALL SINGLE BRACES ON THE SAME SIDE OF THE FRAME WEB. •• 10' a 11 1/2" PURLINS REQUIRE 3 LiOLTS AT EACH END OF PURLIN LAP. "E °""-°''°''°' ",, "° °" TYPICAL FLF�NGE BRACE CONNECTIONS REV. wiC:07/D1/09 R[V. N0. 00 BROCAE 11CONT. PURLIN LAP SHOWN, CONT. GIRT do SIMPLE PURLIN EN51 B 1 ZEE GIRT WS01 G3 HD,DER TO CLIP' (PCI) GDOR HEADER `A I I EQUAL 3" EQUAL rT_T i F70 I I I I I OPENING I I HEIGHT SECTION A -A WS20F9 yQ GIRT CLIP (PGI) MAY BE S )OP WELDED (CC1 OR GCA-) 7" & 8 1/2" GIRT GIRT CONN. AT COLUMN OUTSET CONTINUOUS GIRT 1. UNLESS NOTED, USE 1/2 X 1 1/2 A325 -N BOLT (49080) AND NUT (47120) W/0 WASHERS. SNUG TIGHTEN BOLTS FOR ALL SECONDARY CONNECTIONS. 2. FLANGE BRACES ARE AN INTEGRAL PART OF THE STABILITY OF THE STRUCTURAL SYSTEM AND MUST BE PROPERLY INSTALLED PRIOR TO ERECTION OF Wi.LL AND ROOF SHEETS. 3. REMOVAL OR ALTERATION OF ANY COMPONENT IS PROHIBITED. SINGLE JAMB A307 THIN HEAD BOLT (096636) At NUT (095032) HEADE=R TC JAMB ANY HEADER, ANY SINGLE JAMB WS01H2 TT ADJUST. CODES GAGE EIGHTHS INCHINCHES1 LENGTH rrrI-millimeters ADJUST. CODES GAGE I HTH INCHES LENGTH rrrT millimeters SHAPE GAGE DEPTH SHAPE GAGE Z = ZEE 11 = 0.113 07=7' ZS=ZEE 11 =0.113 C=CEE E = LOW EAVE STRUT 12=0.098 08 = 8 1/2" CS =CEE 12 = 0.098 H - HIGH EAVE STRUT 13 = 0.088 10 - 10" ES - LOW EAVE STRUT 13 - 0.088 ( j 14 = 0.079HS 11 = 11 1/2" - HIGH EAVE STRUT 14 = 0.079 15 = 0.073 BB =BACK TO BACK CEE = 16 = 0.068 FB - FACE TO BACK CEE 15 = 0.073 FF = FACE TO FACE CEE 16 - 0.068 17 0.060 17 - 0.060 SECONDARY PART MARK COMMON GENERATED MARK NUMBER NUMBERS REv. w;Lo7/DI/0+a R1- No. Do EN5182 SPECIAL SECONDARY PAR COMMON GENERATED MARK MARK KEY NUMBERS L JAMB CAN BE 1 1/2' DEEPER RODS WTH 0 GIRT) (2) 1/2" A307 THIN THAN HE AMB SGRr ORATT a RT SECTION 8 1/2- GIRT CLIP (GC5) 10" GIRT CLIP (GCE-) MAY BE SHOP WELDED (GC2 OR GCB-) 1 It ¢ COLUMN L -ZEE GIRT SHOWN CEE GIRT SIMILAR CORNER COLUMN ENOWAL L CART GIRT � y s 8 1/2" & 10" INSET GIRT UALILC k.AM I E.LIr T AT 7" & 10" GIRT (RIGHT SHOWN) (GC18-) AT 8 1/2" GIRT (GC20-) AT 11 1/2" GIRT GIRT CONN. AT COLUMN REV. DATE. 07,23/13 1RE v. ea.w INSET GIRTS WSO4E2 GIRT CLIP (BOLTED) (WELDED) (PG1) (GCI) AT 7" GIRT CORNER COLUMN (PCI) (GC1) AT 8 1/2` GIRT (GCD_) (GCA_) AT 10" CIRT ENDWALL (GCD_) (GCA_) AT 11 1/2" GIRT GIRT, SIDEWALL GIRT �' 'j A FRAME GIRT CLIP (BOLTED)(WELDED) ( •'" ) (GC64_) AT 7" GIRT GIRT FILLER ANGLE (GC34_)(GC65_) AT 8 1/2" CART (GFA-) W/ (4) 55307 (GC62_)(CC66_) AT 10" GIRT (CC63_)(GC67-) AT 11 1/2" GIRT "•• - 5EE DETAIL WSR002 FOR BOLTED CLIP TO 7" GIRT °ATE°°/'°/13 "E'7 No,00 GIRT CONN. AT CORNER COLUMN WSR001 INSET GIRT AT EW, ANY OUTSET GIRT AT SW THE BUTLER MFG. ENGINEER'S SEAL APPLIES ONLY TO THE WORK PRODUCT OF BUTLER MFG AND DESIGN AND PERFORMANCE REQUIREMENTS SPECIFIED BY BUTLER. THE BUTLER MFG. ENGINEER'S SEAL DOES NOT APPLY TO THE PERFORMANCE OR DESIGN OF ANY OTHER PRODUCT OR COMPOAENT FURNISHED BY BUTLER EXCEPT TO ANY DESIGN OR PERFORMANCE REQUIREMENTS SPECIFIED BY BUTLER. 'AKE TEAM GABLE GIRT CONN. TO RAKE BEAM INSET GIRTS GIRT CLIP (BCI TED)(WELDED) (GC5) (GC2) AT 8 1/2" CART (GCE_) (GCB_) AT 10' GIRT 8 1/2" & 10" INSET 1 SIDEWALL GIRT �i .9 i s �J 6 ¢ FRAME GIRT CLIP (BOLTED)(WELDED) ( ►'• )(GC64-) AT 7" GIRT GIRT FILLER ANGLE (GC34_)(GC65_) AT 8 1/2" GIRT (GFA_) W/ (3) 55307 (GC62-)(GC66-) AT 10' GIRT (GC63-)(GC67_) AT 11 1/2' GIRT SEE DETAIL WSR007 FOR BOLTED CLIP TO 7" GIRT 8 1/2" & 10- INSET SW CARTS °A"°°/'°/" REY 140,001GIRT CONN. AT CORNER COLUMN WSR004 ANY INSET GIRT AT EW, INSET GIRT AT SW 4f LI NOTE: BEFORE FASTENING THE CEE MEMBER TO THE ZEE MEMBER. BE SURE TO CLAMP THE CEE AND ZEE AT THE COMMON INSIDE CORNER TO ASSURE A TIGHT FIT. (GIRT CA0521P 14-14 060) (WELDED) STRUCT FSNR/(55307) (GCDO52060) (BOLTED) AT THIRD POINTS A A I I I o t ¢ COLUMN 1 1/2- CEE 2'CEE GIRT DEPTH FSNR AT THIRD IS 1 1/2' LESS POINTS (55307) THAN ZEE GIRT. 14 SECTION A - A 07/01/0e REV. No CO PURLIN AND GIRT SIZES REV. DA7E:OG/18/IR s EV. N0 a GIRT CONN. AT COLUMN EN53F1 8 1/2` 216mm WS01AV OUTSET SIMPLE ZEE W/ NESTED CEE OPTION SECOND CEE ON A DOUBLE FOR FUS UP TO 9' X 9' USE (3) 1/4•-14 X 1 1/4" JAMB E HELD BACK 6' FROM SDS (55307) LOCATED APPROX AS SHOWN. EACH END OF MAIN JAMB. NO CLOSER THAN 3/8' FROM EDGE A OF CLIP OR HOLES, SCREW SPACING NOT LESS THAN 3/4" APART. FIELD LOCATE AND DRILL (2) 9/16' C O DIAMETER HOLES IN ZEE GIRT \ p TO ATTACH JAMB (2) 1/2" X 1 1/2` A325 BOLT (49080) A 0 JAMB, SINGLE 0 OR DOUBLE DOUBLE JAMB lIR1 JAMB BASE CONNECTION Bff STATION CLIP (PG1) ' ADW C110N 1/2- A307 THIN a HEAD BOLT (096636) ZEE GIRT \ �" AT 24 O.C.o ( BY BUILDER) BASE MEMBER I 1/2" ANCHOR do NUT (095032) (JAMB SUPPORT \ ' A L JAMB CAN BE 1 1/2' DEEPER RODS WTH 0 GIRT) (2) 1/2" A307 THIN THAN HE AMB SGRr ORATT a RT SECTION DOUBLE JAMB CONNECTION HARDENED WASHER RPME�6 (PERI 1 1/4* HEAD BOLT (096636) JAMB, 6" & NUT (095032) JAMB BASE ATTACHMENT SINGLE OR DOUBLE MAX I a ( j SINGLE OR DOUBLE JAMB JAMB CAN BE 1 1/2` DEEPER CONCRETE FSNR I I I II II SECTION A -A V. DAT[:11/30/15 REV. W WS2082 THAN THE JAMB SUPPORT GIRT. (ONLY EXCEPTION: 11 1/2' JAMB AT 24 O.C.o ( BY BUILDER) BASE MEMBER I CAN BE USED W/ 8 1/2" GIRT) ALIGN JAMB AND GIRT AT BL. LOCATION: L JAMB CAN BE 1 1/2' DEEPER _M CrE.w P01 CLIP = 3 3/4' AT 7', 8 1/2% 10' GIRTS BUILDERS PO* THAN HE AMB SGRr ORATT a RT SECTION A -A PCV1067 CLIP - 4 3/4" AT 11 1/2' GIRTS JAMB TO GIRT Rte. MT-- 07/01/09 1 REV. NO 00 JAMB BASE ATTACHMENT WS20B8 SINGLE OR DOUBLE JAMB, ANY ZEE GIRT SINGLE OR DOUBLE JAMB THIS DRAWING, INCLUDING THE INFORMATION HEREON, REMAINS THE PROPERTY BUTLER MANUFACTURING OF BUTLER MFG. IT IS PROVIDED SOLELY FOR ERECTING THE BUILDING DESCRIBED 1640 GENESSEE ST. KANSAS CITY, MO 64102 IN THE APPLICABLE PURCHASE ORDER AND SHALL NOT BE MODIFIED, REPRODUCED OR USED FOR ANY OTHER PURPOSE WITHOUT PRIOR WRITTEN APPROVAL OF BUTLER MFG. REV. DATE BY: DESCRIPTION: THE GENERAL CONTRACTOR AND/OR ERECTOR IS SOLELY RESPONSIBLE FOR ACCURATE GOOD QUALITY WORKMANSHIP IN ERECTING THIS BUILDING IN ACCORDANCE WITH THIS DRAWING, DETAILS REFERENCED IN THIS DRAWING, ALL APPLICABLE BUTLER MFG. ERECTION GUIDES, AND INDUSTRY STANDARDS PERTAINING TO PROPER ERECTION, INCLUDING THE CORRECT USE OF TEMPORARY BRACING. DRAWNGSCALE: NTS WALL SECONDARY SED'S BOLDER: North Valley Building Systems, Inc. CUSTOMER: LOCATION: Chico, California QCT: Gig 7 Crop Insurance BUILDERS PO* 10 3. C 677J .I.f� t,. ChM - (0)F CALIF 0�\ JOB A 16-008721-01 DATE: BUTLER 5/11/2016 r. DRAWWCFECK Butler Manufacturing P JJLLD RFG VPC VERSION: 2016.1 21 a dvleion of BIueScope Buildnpe North America, Inc. Y 660' SITE PLAN NO SCALE 660' GUYNN AVENUE NOTE: ENGINEER OF RECORD HAS NOT VISITED THE PROPOSED CONSTRUCTION SITE. DIMENSIONS AND LAYOUT OF EXISTING BUILDINGS AND SITE HAS BEEN DEDUCED FROM INFORMATION PROVIDED BY THE CONTRACTOR. CONTRACTOR MUST FIELD VERIFY PLANS AND ALL DIMENSIONS PRIOR TO CONSTRUCTION AND IMMEDIATELY REPORT ANY DISCREPANCIES TO SUMMIT STRUCTURAL DESIGN. Complete construction Post Debris Recovery final report documentation and V.O.C. Compliance Certification submit to Building Division prior to final building inspection See attached— Minimum erosion control and sediment controls for projects disturbing less than one acre �rovide special inspection reports to the Building Inspector for review and approval prior to final building field inspection .v s a MINIMUM EROSION AND SEDIMENT ,} CONTROLS FOR PROJECTS DISTURBING I F�� THAN (SNF ArRF G-10 THE BMP'S (BEST MANAGEMENT PRACTICES) LISTED 2013 CPC BELOW MUST BE IN PLACE DURING THE RAINY SEASON I L m- u (OCTOBER 15 THROUGH APRIL 15) AND MAY BE CHAPTER 16, DIVISIONS I, II, III, AND IV U.N.O.: REQUIRED AT OTHER TIMES BASED ON WEATHER AND 2013 CFC SITE CONDITIONS THROUGHOUT THE YEAR. THE BMP'S SEISMIC IMPORTANCE FACTOR: 1 LISTED ARE MINIMUM REQUIREMENTS AND ADDITIONAL CODE AND AMENDMENTS BMP'S COULD BE REQUIRED BASED ON SITE O CONDITIONS. Q0 1. STABILIZED ENTRY. PROVIDE MINIMUM 3" TO 6" CO FRACTURED ROCK 50' LONG x 15' WIDE BY 6" DEEP BUTTE COUNITY OVER CONSTRUCTION GRADE FABRIC. 2. ALL SOILS TRACKED ONTO PAVED ROADWAYS MUST OCCUPANT OCCUPANCYOSEPARATION: NONE 2 ._ BE CLEANED ON A DAILY BASIS. WHEN STREETS ARE R(ORDINARY STEEL CONC. BRACED FRAMES)= 3.25 WET OR DURING A RAIN EVENT THERE SHALL BE NO I TRACKING OF SOILS ONTO THE STREET. 3. WATTLES SHALL BE INSTALLED PROPERLY. BEHIND ALLOWABLE AREA: 18,000 S.F. (BASIC) CURB OR SIDEWALKS. 4. ROCK BAGS (MINIMUM 2 PER SIDE) AT ALL DRAIN INLET LOCATIONS WITHIN 150' OF THE PROJECT SITE. 5. INTERNAL FILTERS SHALL BE PLACED INSIDE EACH ALLOWABLE STORY/HEIGHT: 2/55' DRAIN INLET. S. TRASH BARS SHALL BE PLACED ACROSS THE BACK STRUCTURAL DESIGN. OF ALL DRAIN INLETS. 7. STABIUZE ALL DISTURBED SOILS IN THE FRONT YARD AREAS WITHIN 15' OF THE BACK CURB OR SIDEWALK. (STRAW OR EROSION BLANKETS MAY BE USED FOR iq 2013 CALIFORNIA BUILDING CODE THIS APPUCATION) S. STABILIZE ALL SLOPES WHERE EROSION COULD OCCUR AND CAUSE SILT RUN OFF. (STRAW, VISQUEEN OR q 2013 CALIFORNIA PLUMBING CODE EROSION BLANKETS MAY BE USED FOR THIS EXTERIOR WALL SEPARATION: NONE APPLICATION) 9. ALL PAINT, FUEL. CONSTRUCTION PRODUCTS ETC. 2013 CALIFORNIA ENERGY CODE SHALL BE STORED IN A COVERED LOCATION AWAY FROM SIDEWALKS AND STORM DRAIN INLETS. 10. PORTABLE CHEMICAL TOILET'S IF PROVIDED ON THE ❑ 2013 CALIFORNIA BUILDING CODE— SITE MUST BE KEPT OFF OF STREETS AND SIDEWALKS AND A LEAST 50' FROM THE NEAREST STORM DRAIN. 11. ALL TRASH MUST BE COLLECTED AND STORED ❑ 2013 CALIFORNIA FIRE CODE PROPERLY. DO NOT LET ITEMS SUCH AS DRYWALL MUD BOXES, PAINT BUCKETS, CLEANING MATERIAL CONTAINERS, ETC. COME IN CONTACT WITH ANY COMPLETION OF TIIIS REVIEW DOES NOT AUTHORIZE RAINFALL OR STORM WATER RUNOFF. 12. PROVIDE A DESIGNATED AREA FOR CONCRETE WASHOUT. HAY BAILS LINED WITH VISQUEEN MAY BE STATE OR LOCAL. REGULATIONS. USED FOR THIS APPLICATION. ROLLAWAY BINS MAY AUTOMATIC SPRINKLER: NONE ALSO BE USED. ALL CONCRETE WASHOUT SYSTEMS SHALL BE PLACED OFF OF THE PAVED STREETS. 13. AFTER INSTALLATION OF THE ABOVE ITEMS ARE NUMBER OF EXIT REQ'D: 1 COMPLETE, A MAINTENANCE PROGRAM NEEDS TO BE DEVELOPED TO INSURE THE CONTINUED EFFECTIVENESS OF YOUR BMP'S. SPECIAL INSPECTION REQUIREMENTS: HIGH STRENGTH BOLTING OF METAL BUILDING ABOVE BY OTHERS PROJECT DIRECTORY OWNER: GIG 7 CROP INSURANCE GUYNN AVE CHICO, CA PROJECT ENGINEER: SUMMIT STRUCTURAL DESIGN 383 RIO UNDO AVE CHICO, CA 95926 (530) 592-4407 GENERAL CONTRACTOR: NORTH VALLEY BUILDING SYSTEMS, INC. 30 SEVILLE COURT CHICO, CA 95928 (530) 345-7296 65'X 130' X 18'-0" METAL BUILDING NOTE: BUILDING LOCATIONS SHOWN AS APPROXIMATE. ACTUAL DIMENSIONS SHALL BE VERIFIED IN THE FIELD. DRAWING INDEX Al ............... SITE PLAN /CODE ANALYSIS A2 ............... ELEVATION S/SECTI ON /FLOOR PLAN 1...............BUILDING FOUNDATION rndR' VICINITY MAP: NOT TO SCALE CHICO, APN: ;I ARCHITECT OF RECORD GOVERNING CODES: 2013 CBC S� ARofty �y GREGORY PEITZ, AIA v k 383 RIO UNDO AVE * 0��. C 11 CHICO, CA 95926 (530) 894-5719 j —7? 4 r A CODE ANALYSIS 2013 CEC DESIGN LOADS FOR NEW BUILDINGS PER BUTLER BUILDING SYSTEMS 2013 CPC I L m- u 2013 CMC CHAPTER 16, DIVISIONS I, II, III, AND IV U.N.O.: 2013 CFC JAN 17.2017 SEISMIC IMPORTANCE FACTOR: 1 2013 CALIF. HEALTH & SAFETY CODE AND AMENDMENTS INTERWEST 2013 CALIF. BUILDING ENERGY EFFICIENCY STANDARDS SPECTRAL RESPONSE COEFFICIENTS: SDS = 0.5379, SDI = 0.3400 2013 CALIF. BUILDING CODE CHAPTER 11 SEISMIC DESIGN CATEGORY: D 2013 CAL GREEN BUTTE COUNITY OCCUPANCYGROUP:U- AGRICULTURALEQUIPMENTSTORAGE BUILDIING DIVISION SEISMIC BASE SHEAR: SEE ATTACHED CALCULATIONS BY BUTLER BUILDING SYSTEMS OCCUPANT OCCUPANCYOSEPARATION: NONE 2 ._ AP[ APP" v =u R(ORDINARY STEEL CONC. BRACED FRAMES)= 3.25 1 I C) WIND: ALLOWABLE HEIGHT AND BUILDING AREAS (TABLE C102.1) WIND SPEED: 110 MPHR ALLOWABLE AREA: 18,000 S.F. (BASIC) EXPOSURE:WIND JA 11 10 2011 ACTUAL FLOOR AREA: 8450 S.F. OVERALL (6500 S.F. ENC D) GRAVITY LOADS: -OSED)— LIVE LOADS: ALLOWABLE STORY/HEIGHT: 2/55' ROOF..............................................20 PSF REDUCIBLE REVIEWED FOR CODE COIF/IPLIANC FOUNDATION STRUCTURAL DESIGN PER SHEET S1 AND ATTACHED STRUCTURAL CALCULATIONS BY SUMMIT STRUCTURAL DESIGN. ACTUAL STORY/HEIGHT: 1/18'-0" USING THE FOLLOWING CODES: ❑ 2013 CALIFORNIA RESIDENTIAL CODE CONSTRUCTION TYPE: TYPE IIB iq 2013 CALIFORNIA BUILDING CODE 2013 CALIFORNIA FLECRTICAL CODE FIRE -RESISTANCE RATINGS: NONE q 2013 CALIFORNIA PLUMBING CODE EXTERIOR WALL SEPARATION: NONE 2013 CALIFORNIA MECHANICAL CODE 2013 CALIFORNIA ENERGY CODE 2013 CALIFORNIA GREEN BUILDING STANDARDS CODE RATED CONSTRUCTION: CHAPTER 7 ❑ 2013 CALIFORNIA BUILDING CODE— STI:UCfURAL PROVISIONS ONLY PROJECTIONS: NON -RATED (SECTION 704.2) ❑ 2013 CALIFORNIA FIRE CODE I! ❑ OTHER: OPENINGS: UNLIMITED UNPROTECTED (TABLE 705.8) COMPLETION OF TIIIS REVIEW DOES NOT AUTHORIZE CONSTRUCTION TO PROCEED IN VIOLATION OF ANY FEDERAL, STATE OR LOCAL. REGULATIONS. AUTOMATIC SPRINKLER: NONE BY: DATE: I I r7/fl NUMBER OF EXIT REQ'D: 1 l %:PzN`vTS'I' CONS U LTING GROUP STRUCTURAL DESIGN DESIGN LOADS FOR NEW BUILDINGS PER BUTLER BUILDING SYSTEMS I L m- u A) THE STRUCTURE HAS BEEN DESIGNED FOR THE FOLLOWING CRITERIA PER CBCTRR.EV O CODE COMPLIANCE CHAPTER 16, DIVISIONS I, II, III, AND IV U.N.O.: B) SEISMIC: JAN 17.2017 SEISMIC IMPORTANCE FACTOR: 1 MAPPED SPECTAL RESPONSE ACCELERATIONS: Ss = 0.618, S1= 0.276 INTERWEST SEISMIC SITE CLASS: D CONSULTING GROUP SPECTRAL RESPONSE COEFFICIENTS: SDS = 0.5379, SDI = 0.3400 SEISMIC DESIGN CATEGORY: D BASIC SEISMIC -FORCE -RESISTING SYSTEMS: ORDINARY STEEL MOMENT FRAMES AND ORDINARY STEEL CONCENTRICALLY BRACED FRAMES SEISMIC BASE SHEAR: SEE ATTACHED CALCULATIONS BY BUTLER BUILDING SYSTEMS RESPONSE MODIFICATION FACTOR: R(ORDINARY STEEL MOMENT FRAMES)= 3.5 R(ORDINARY STEEL CONC. BRACED FRAMES)= 3.25 ANALYSIS PROCEDURE USED: SEE ATTACHED CALCULATIONS BY BUTLER BUILDING SYSTEMS C) WIND: (M WIND SPEED: 110 MPHR EXPOSURE:WIND JA 11 10 2011 BASIC WIND PR PRESSURE: 24.55 PSF D) GRAVITY LOADS: 107-P- UI 111 O _ ^�/VEST LIVE LOADS: I G�QVp ROOF..............................................20 PSF REDUCIBLE FOUNDATION STRUCTURAL DESIGN PER SHEET S1 AND ATTACHED STRUCTURAL CALCULATIONS BY SUMMIT STRUCTURAL DESIGN. oQ�pFESS/O/y C. spy F� c�0 / LLJ 0 188-, m * p. 6/30 18 CIV( gTFOF aoU THESE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE ONLY WITH THE ATTACHED STRUCTURAL CALCULATIONS 383 Rio Lindo Ave. Suite 200 Chico, CA 95926 P. 530.592.4407 SummitChico.com NORTH VALLEY BUILDING SYSTEMS UJ V)U (— z V / -J z Z 1170 Q VU V O W _U Q =U LU00- LL > UzQ Z hoz z < pp CD � Q L1J G W p X 10 REVISIONS: 01 12/29/16 RTPC#1 DATE: 05/09/16 SCALE: NTS DRAWN BY: ACJ JOB NUMBER: 16-210 SHEET: LJV 1L_L_I x L! 11 TI, LI... . VW__ -- I♦. -- ENDWALL ELEVATION (OTHER SIDE SIMILAR) NO SCALE BUILDING SECTION NO SCALE HARVEST _o I 00 CV NOTE: HAND -ACTIVATED DOOR -OPENING HARDWARE SHALL BE CENTERED BETWEEN 34 INCHES AND 48 INCHES ABOVE THE FLOOR. LATCHING AND LOCKING DOORS THAT ARE HAND -ACTIVATED AND WHICH ARE IN A PATH OF TRAVEL SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER -TYPE HARDWARE, PANIC BARS, PUSH-PULL ACTIVATION BARS, OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. FURTHERMORE, THE MAXIMUM EFFORT FOR BOTH INTERIOR AND EXTERIOR DOORS IS 5 POUNDS. I, ►AET A I DnnC' (I _ ■rA. 17 0 0 cV N BUTLERIB II ROOF: COOL HARVEST ALL GUTTERS: COOL HARVEST BUTLERIB II WALLS: COOL DESERT BEIGE • DOWNSPOUTS AT DOWNSPOUTS AT ROOF ONLY AREA: ENCLOSED AREA: COOL HARVEST SIDEWALL ELEVATION (OTHER SIDE SIMILAR) COOL DESERT BEIGE NO SCALE 130'-0" 130'-4" OUT -TO -OUT OF CONCRETE 1 14 20'-0" T 20'-0" T 20'-0" 20'-0" 5 20'-0" N. 30'-0" ROOF ONLY w . ........... . . ........ ........... 1 DOOR SCHEDULE: (4) 14x16 ROLL DOOR BY BUTLER MFG FLOOR P LAN (2) 3070 STEEL PEDESTRIAN DOOR BY BUTLER MFG NO SCALE �,UNSULTING GRni,p NOTE: ALL FUTURE ELECTRICAL SHALL CONFORM TO 2013 CEC (CALIFORNIA ELECTRICAL CODE). NO ELECTRICAL WILL BE PROVIDED UNDER THIS PERMIT. 1 C. ✓CD D��F�c� C 0 6 8 0 J� CIVIL OF CA THESE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE ONLY WITH THE ATTACHED STRUCTURAL CALCULATIONS 383 Rio Lindo Ave. Suite 200 Chico, CA 95926 P. 530.592.4407 SummitChico.com NORTH VALLEY BUILDING SYSTEMS Z 0 LU Uz LU Q V J 00 \ z r i2 �O OC U U 0 ,-., OU U -i = QOG U CL O Li LU LU (D < _J z z W �_zi Uj Z m V J Uj LUQ r L O y 0 0 J LL REVISIONS: 1 12/29/16 RTPC#1 DATE: 06/01/16 SCALE: NTS DRAWN BY: ACJ JOB NUMBER: 16-210 SHEET: q 2 GENERAL NOTES 1. GENERAL ALL WORK SHALL CONFORM TO THE 2013 CBC AND ALL APPLICABLE LOCAL CODES. THE ENGINEER HAS PROVIDED AND IS RESPONSIBLE FOR SPECIFIC STRUCTURAL ITEMS ONLY, ALL OTHER REQUIREMENTS OF THE BUILDING CODE INCLUDING WATERPROOFING, FIREPROOFING, DRAINAGE, HANDICAP ACCESSIBILITY, EGRESS REQUIREMENTS, PARKING, AND ALL OTHER DESIGN REQUIREMENTS NOT SPECIFICALLY SHOWN IN THE STRUCTURAL DESIGN CALCULATIONS ARE THE RESPONSIBILITY OF THE CONTRACTOR OR OWNER. SHOULD ANY CHANGES BE MADE FROM THE DESIGN AS SPECIFIED IN THESE DOCUMENTS WITHOUT THE WRITTEN APPROVAL FROM THE ENGINEER, THEN THE ENGINEER WILL ASSUME NO RESPONSIBILITY FOR ANY ELEMENT OR SYSTEM OF THE STRUCTURE. THE DRAWINGS AND CALCULATIONS REPRESENT THE FINISHED STRUCTURE, AND, UNLESS SPECIFICALLY NOTED OTHERWISE, DO NOT SHOW THE METHOD OF CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR THE METHOD OF CONSTRUCTION, AND SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE PUBLIC, CONSTRUCTION WORKERS, AND THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE FORMING, SHORING, BRACING, SCAFFOLDING, ETC. IF A PARTICULAR FEATURE OF CONSTRUCTION IS NOT FULLY SHOWN ON THE DRAWINGS OR IN THE CALCULATIONS, THEN IT SHALL BE CONSTRUCTED IN THE SAME CHARACTER AS SIMILAR CONDITIONS THAT ARE SHOWN ON THE DESIGN DOCUMENTS. ANY CONDITIONS NOTED AS EXISTING MUST BE FIELD VERIFIED BY THE CONTRACTOR, AND ANY DISCREPANCIES MUST BE BROUGHT TO THE ATTENTION OF THE ENGINEER WITHOUT PROCEEDING WITH CONSTRUCTION PRIOR TO THE REVIEW OF THE ENGINEER. ALL WATERPROOFING AND FLASHING (ROOFS, FOUNDATIONS, GARAGE FLOORS, ETC...) IS THE RESPONSIBILITY OF THE CONTRACTOR OR OWNER. SPECIAL INSPECTION: SPECIAL INSPECTION PER SECTION 1704 OF THE CBC SHALL BE PROVIDED FOR THE FOLLOWING TYPES OF CONSTRUCTION: HIGH STRENGTH BOLTING OF METAL BUILDING ABOVE THE SPECIAL INSPECTOR SHALL BE ACCEPTABLE TO THE ENGINEER OF RECORD AND BUILDING DEPARTMENT, SHALL BE ICBO QUALIFIED, AND THEIR EXPERIENCE SHALL BE COMMENSURATE WITH THIS TYPE OF PROJECT. T1+E SFECl Al- rg Spe:cToR SHALL. SE BRI�� FaRSYTRE-AP�LTED TEStIN4 coplSvt-TA[�ITS 2. SITE WORK /FOUNDATIONS �(1530)3ql - (,(,Zr, ASSUMED MAXIMUM SOIL BEARING = 1500 PSF (NO SOILS REPORT PROVIDED) FOUNDATIONS SHALL NOT BE SCALED FROM PLAN OR DETAIL DRAWINGS. FILL MATERIAL SHALL BE FREE FROM DEBRIS, VEGETATION, AND OTHER FOREIGN SUBSTANCES. USE 4" DIAMETER PERFORATED PIPE SUB -DRAIN BEHIND ALL RETAINING WALLS. SLOPE PIPE TO DRAIN TO DAYLIGHT. 3. CONCRETE / REINFORCING CONCRETE SHALL HAVE A MINIMUM 28 DAY STRENGTH OF 3,000 PSI U.N.O. ALL CEMENT USED SHALL CONFORM TO ASTM C-150 AND SHALL BE TYPE II OR TYPE III LOW ALKALI. AGGREGATE SHALL CONFORM TO ASTM C-33 AND SHALL NOT CONTAIN MATERIALS WHICH ARE ALKALI REACTIVE AS DETERMINED BY ASTM C-227,289, AND 295. IF TEST DATA IS UNAVAILABLE IN REGARDS TO ALKALI REACTIVE MATERIALS, PROVIDE CEMENT WITH A MAXIMUM ALKALI CONTENT LESS THAN 0.45% BY WEIGHT. CONCRETE EXPOSED TO FREEZING OR THAWING SHALL BE PROTECTED IN ACCORDANCE TO THE LATEST EDITION OF THE ACI CODE AND CBC APPENDIX, CHAPTER 19. REINFORCEMENT COVER SHALL BE AS FOLLOWS: CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO SOIL: 3" CONCRETE WITH SOIL OR WEATHER EXPOSURE: #5 BARS AND SMALLER 1 %" #6 BARS AND LARGER 2" CONCRETE WITHOUT SOIL OR WEATHER EXPOSURE: 3/4" REINFORCEMENT SHALL BE GRADE 60 PER ASTM A615 U.N.O. LAP REINFORCING 40 BAR DIAMETERS U.N.O. #5 AND LARGER REBAR SHALL NOT BE RE-BENT. ALL REINFORCING STEEL AND ANCHOR BOLTS SHALL BE ACCURATELY LOCATED AND ADEQUATELY SECURED IN POSITION BEFORE AND DURING CONCRETE PLACEMENT. ANCHOR BOLTS SHALL BE ASTM A 307 AND SHALL BE PROVIDED NEW, W/O EXCESSIVE RUST. ANCHOR BOLTS PER METAL BUILDING MFR. FRAME/POST BASE POURED WITH FOOTING 47 , CONSTRUCTION JOINT, TYP. ,• /. TYPICAL HAIRPIN PER PLAN SLAB POURED OVER FOOTING WITH CONSTRUCTION JOINT BLOCK OUT DETAIL 6 NO SCALE S _ A w w z 0 0 L_ 0 0 1.- 1Ln 0 (D I OO 0 d- C A 0 I N N 130'-0" 130'-4" OUT—TO—OUT OF CONCRETE 1 \`/ \"/ \ '/ n5 \6/ 7 i i r I I F3A/) ---1 r---------� J�o.--------1 r---------� r--- -------1 I 18" SQ. CONCRETE PEDESTAL X HEIGHT p, — — TYP. AS REQ'D (2 PLCS) sl 30' (1) #4 HAIRPIN I TYPICAL, (16) PLCS LSLAB—ON—GRADE PER NOTE 3 I I I / I r F3A//L I I /F4.5 PROVIDE SAWCUT FOR I Fa - CRACK CONTROL AT L 10'-0" MAX SPACING IN -,\\F3.5 BOTH DIRECTIONS. I I SLOPE PER CONT'R I SLAB—ON—GRADE PER NOTE 3 r -1 L I F3.5 I PARTITION LINE FACE OF GIRT 0 N ( / TYP. / 3 TYP / II S1 \ S1 r Ll II--- _ --I -----------I I -----------I I -----------I I----------� I I l l F3A F4 F4 F4 F4 F3B L F4.5 ALL DIMENSIONS INCLUDING ANCHOR BOLT LOCATIONS AND SPACING SHALL BE TAKEN FROM THE FINAL "FOR CONSTRUCTION" SET OF METAL BUILDING MFR DRAWINGS. FOUNDATION DRAWINGS ARE GENERAL IN NATURE AND ONLY REPRESENT FOUNDATION SIZES, REINFORCING, AND ANCHOR ROD EMBEDMENT. FOUNDATION PLAN RAMP EDGE OF SLAB AT 18" ROLL UP DOOR OPENINGS DRAINAGE BY OTHERS_ 3 4" PER PLAN SLAB ON GRADE 11=II - fi00 b° SLAB ON GRADE AT SIM CONDITION 0 #4 VERT. AT 24" O.C. -I (AT TWO—POUR FNDN) r (2) #4 CONT. 1'-0" TOP AND BOTT FOOTING AT ROLL UP DOOR SCALE: 1/8" = 1'-0" 6 S1 NOTE: CORROSION PROTECTION CE OF COLUMN WHERE REQUIRED FOR EXTERIOR T EXPOSURE BY OTHERS EDGE OF STEEL STEEL COLUMN, BY OTHERS A.B. PER PLAN 2" HOOK REINFORCING AROUND BOLTS AT HAIRPIN TIE 3 4" i———/—/- .. ......... ._..... L L...._._ ,__...__L ._._......_............. ..... .... .... ... ........ . I =uiI 20"-0" 20"-0" 20•-0•• 20•-0"" 20"—U" II (4) 3/4" DIA NO SCALE D2 MARK (DIM X) X ROOF ONLY X (THICKNESS) III II 6" 3'-0" 6" 19'-6" 3'-0" 3'-0" 31-0» 3'-0" 3'-0" 3>-0» 19'-6" 29'-6" 6" TOP N BOTT. F3B 3'-0" II /f 140-01' ) ff 3'— 0" 14'-0" EDGE jF4 I I IF4 BOTT. IF4 3'-6" X 3'-6" /F3A F4 1 ,F36 PER PLAN WHERE OCCURS i i r I I F3A/) ---1 r---------� J�o.--------1 r---------� r--- -------1 I 18" SQ. CONCRETE PEDESTAL X HEIGHT p, — — TYP. AS REQ'D (2 PLCS) sl 30' (1) #4 HAIRPIN I TYPICAL, (16) PLCS LSLAB—ON—GRADE PER NOTE 3 I I I / I r F3A//L I I /F4.5 PROVIDE SAWCUT FOR I Fa - CRACK CONTROL AT L 10'-0" MAX SPACING IN -,\\F3.5 BOTH DIRECTIONS. I I SLOPE PER CONT'R I SLAB—ON—GRADE PER NOTE 3 r -1 L I F3.5 I PARTITION LINE FACE OF GIRT 0 N ( / TYP. / 3 TYP / II S1 \ S1 r Ll II--- _ --I -----------I I -----------I I -----------I I----------� I I l l F3A F4 F4 F4 F4 F3B L F4.5 ALL DIMENSIONS INCLUDING ANCHOR BOLT LOCATIONS AND SPACING SHALL BE TAKEN FROM THE FINAL "FOR CONSTRUCTION" SET OF METAL BUILDING MFR DRAWINGS. FOUNDATION DRAWINGS ARE GENERAL IN NATURE AND ONLY REPRESENT FOUNDATION SIZES, REINFORCING, AND ANCHOR ROD EMBEDMENT. FOUNDATION PLAN RAMP EDGE OF SLAB AT 18" ROLL UP DOOR OPENINGS DRAINAGE BY OTHERS_ 3 4" PER PLAN SLAB ON GRADE 11=II - fi00 b° SLAB ON GRADE AT SIM CONDITION 0 #4 VERT. AT 24" O.C. -I (AT TWO—POUR FNDN) r (2) #4 CONT. 1'-0" TOP AND BOTT FOOTING AT ROLL UP DOOR SCALE: 1/8" = 1'-0" 6 S1 NOTE: CORROSION PROTECTION CE OF COLUMN WHERE REQUIRED FOR EXTERIOR T EXPOSURE BY OTHERS EDGE OF STEEL STEEL COLUMN, BY OTHERS A.B. PER PLAN 2" HOOK REINFORCING AROUND BOLTS AT HAIRPIN TIE 3 4" i———/—/- .. ......... ._..... L L...._._ ,__...__L ._._......_............. ..... .... .... ... ........ . I =uiI NO SCALE SLAB ON GRADE PER PLAN J 0 Z W J M Uj 0 o0w�w U m W U zwoU Q REINFORCING PER SCHEDULE 3" CLR REVIEWED I~0P, CODE COMPLIANCE ,SAN 17 2017 INTERWEST CONtcI 11 TINI(-- r-,Rnl)P ANCHOR BOLT SCHEDULE A.B. TYPE FOOTING SCHEDULE EMBEDMENT II (4) 3/4" DIA NO SCALE D2 MARK (DIM X) X S1 X (THICKNESS) III II F3A 3'-0" X 0 X 2'-6" 5 4 E. W., TOP N BOTT. F3B 3'-0" II 3'-0" II 3'-0" (6) EDGE OF STEEL TOP & BOTT. F3.5 3'-6" X 3'-6" X A.B. PER PLAN WHERE OCCURS 4 E. W., TOP & BOTT. F4 4'-0" SLAB ON GRADE PER aL`' X 3'—O" DRAINAGE BY OTHERS—_ 3 4'9 E. W., PLAN WHERE OCCURS L BOTT. F4.5 4'-6" X 4'-6" X 3'-0" (9) V) II TOP II BOTT. Z U I I I I ;f' p (n 1=III- I! II goo _ SLAB ON GRADE AT SIM CONDITION 0 #4 VERT. AT 24" O.C. (AT TWO -POUR FNDN) (1) #4 CONT. EQUAL EQUAL TOP AND BOTT DIM PER SCHEDULE CONTINUOUS FOOTING DETAIL AT SPREAD FOOTING NO SCALE SLAB ON GRADE PER PLAN J 0 Z W J M Uj 0 o0w�w U m W U zwoU Q REINFORCING PER SCHEDULE 3" CLR REVIEWED I~0P, CODE COMPLIANCE ,SAN 17 2017 INTERWEST CONtcI 11 TINI(-- r-,Rnl)P FOOTING SCHEDULE NO SCALE ANCHOR BOLT SCHEDULE A.B. TYPE FOOTING SCHEDULE EMBEDMENT D1 (4) 3/4" DIA 20" D2 MARK (DIM X) X (DIM Y) X (THICKNESS) REINFORCING F3A 3'-0" X 3'—O" X 2'-6" 5 4 E. W., TOP & BOTT. F3B 3'-0" X 3'-0" X 3'-0" (6) #4 E. W., TOP & BOTT. F3.5 3'-6" X 3'-6" X 3'—O" 7 4 E. W., TOP & BOTT. F4 4'-0" X 4'-0" X 3'—O" 8 4 E. W., TOP & BOTT. F4.5 4'-6" X 4'-6" X 3'-0" (9) #4 E. W., TOP & BOTT. FOOTING SCHEDULE NO SCALE ANCHOR ROD SHALL CONFORM TO ASTM F1554 GR. 36 WITH PLATE WASHER 1/2" X 2 1/4" X 2 1/4" SECURED WITH DOUBLE NUTS, TYP. NOTE: SEE ANCHOR BOLT SETTING PLAN PROVIDED BY BUTLER METAL BUILDING CORP. FOR ANCHOR BOLT SPACING. VERIFY ALL NON-STRUCTURAL BOLTS FOR OPENINGS AND DOORS AS THEY MAY OR MAY NOT HAVE BEEN SHOWN ON THIS PLAN. ANCHOR BOLT SCHEDULE NO SCALE S1 NO SCALE Q�OFESS/pN9 C. /0yl F'L L3 :o N 69 80 JI C/ V I L gTFOF CALF I 2 2°1 /Ito THESE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE ONLY WITH THE ATTACHED STRUCTURAL CALCULATIONS 1 383 Rio Lindo Ave. Suite 200 Chico, CA 95926 P. 530.592.4407 SummitChico.com NORTH VALLEY BUILDING SYSTEMS mom ImLU U z ' Q 00 V) z Q J O .. a- U U 1 o w 0 Cr U O w w Q z Qz Ezuj z ::) :D EDo, J �.. Q O w z LL G I O m c --I X L1i l0 01 U_ REVISIONS: DATE: 06/01/16 SCALE: 1/8" = 1'-0" DRAWN BY: ACJ JOB NUMBER: 16-210 SHEET: sl ANCHOR BOLT SCHEDULE A.B. TYPE A.B. SIZE EMBEDMENT D1 (4) 3/4" DIA 20" D2 (4) 3/4" DIA 20" D3 (4) 3/4" DIA 20" ANCHOR ROD SHALL CONFORM TO ASTM F1554 GR. 36 WITH PLATE WASHER 1/2" X 2 1/4" X 2 1/4" SECURED WITH DOUBLE NUTS, TYP. NOTE: SEE ANCHOR BOLT SETTING PLAN PROVIDED BY BUTLER METAL BUILDING CORP. FOR ANCHOR BOLT SPACING. VERIFY ALL NON-STRUCTURAL BOLTS FOR OPENINGS AND DOORS AS THEY MAY OR MAY NOT HAVE BEEN SHOWN ON THIS PLAN. ANCHOR BOLT SCHEDULE NO SCALE S1 NO SCALE Q�OFESS/pN9 C. /0yl F'L L3 :o N 69 80 JI C/ V I L gTFOF CALF I 2 2°1 /Ito THESE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE ONLY WITH THE ATTACHED STRUCTURAL CALCULATIONS 1 383 Rio Lindo Ave. Suite 200 Chico, CA 95926 P. 530.592.4407 SummitChico.com NORTH VALLEY BUILDING SYSTEMS mom ImLU U z ' Q 00 V) z Q J O .. a- U U 1 o w 0 Cr U O w w Q z Qz Ezuj z ::) :D EDo, J �.. Q O w z LL G I O m c --I X L1i l0 01 U_ REVISIONS: DATE: 06/01/16 SCALE: 1/8" = 1'-0" DRAWN BY: ACJ JOB NUMBER: 16-210 SHEET: sl f 2013 CALGreen Residential Mandatory Measures Planning and Design 4.106.2 - Storm Water Drainage and Retention - Projects which disturb less than one acre of soil and are not part of a larger common plan of development shall manage storm water drainage during construction. 4.106.3 - Grading and Paving - Construction plans shall indicate how the site grading and drainage system will manage all surface water flows to keep water from entering building. Exception: Additions or alterations not altering the drainage path. 4.106.4.1- Electric Vehicle (EV) charging - For new constructed dwelling units, install a listed raceway to accommodate a dedicated 208/240 -volt branch circuit. The raceway shall not be less than trade size 1(nominal 1 -inch inside diameter). The raceway shall originate at the main service or subpanel and shall terminate into a listed cabinet, box or other enclosure in close proximity to the proposed location of an EV charger. Raceways are required to be continuous at enclosed, inaccessible or concealed areas and spaces. The service panel and/or subpanel shall provide capacity to install a 40 -ampere minimum dedicated branch circuit and space(s) reserved to permit installation of a branch circuit overcurrent protective device. The service panel or subpanel circuit directory shall identify the overcurrent protective device spaces(s) reserved for future EV charging as "EV CAPABLE". The raceway termination location shall be permanently and visibly marked as "EV CAPABLE". Energy Efficiency 4.201.1-5.201.1 - Low-rise residential (Section 4.201.1) and high-rise residential/hotel/motel (Section 5.201.1) building shall meet or exceed the minimum standards design required by the California Energy Standards. Standards for residential buildings do not require compliance with levels of minimum energy efficiency beyond those required by the 2013 California Energy Code. Water Efficiency and Conservation Indoor Use - 4.303.1- Water Conserving Plumbing Fixtures and Fittings. - Plumbing fixtures and fittings shall comply with the following: 4.303.1.1 - Water closets flush volume shall not exceed 1.28 gals per flush. 4.303.1.2 - Urinals flush volume shall not exceed 0.5 gals per flush. 4.303.1.3.1- Single showerheads shall have a maximum flow rate of not more than 2.0 gpm. 4.303.1.3.2 - Multiple showerheads shall have a combined flow rate of all showerheads and/or shower outlets controlled by a single valve shall not exceed 2.0 gpm or only one shower outlet to be in operation at a time. 4.303.1.4.1- Residential lavatory faucets maximum flow rate shall not exceed 1.2 gpm. The minimum flow rate shall not be less than 0.8 gpm. 4.303.1.4.2 - Lavatory faucets in common and public areas of residential buildings shall not exceed 0.5 gpm. 4.303.1.4.3 - Metering faucets shall not deliver more than 0.25 gals per cycle. 4.303.1.4.4 - Kitchen faucets maximum flow rate shall not exceed 1.8 gpm. Kitchen faucets may temporarily increase the flow above the maximum rate, but not to exceed 2.2 gpm. Note: When complying faucets are unavailable, aerators or other means may be used to achieve reduction. 4.303.2 - Plumbing fixtures and fittings shall be installed in accordance with the Plumbing Code. Outdoor Use - 4.304.1- Irrigation Controllers - Automatic irrigation system controllers for landscaping by the builder and installed at the time of final inspection shall comply with the following: 1. Controllers shall be weather- or soil moisture -based controllers that automatically adjust irrigation in response to changes in plant watering needs as weather or soil conditions change. 2. Weather -based controllers without integral rain sensors or communication systems that account for rainfall shall have a separate wired or wireless rain sensor which connects or communicates with the controller(s). Material Conservation and Resource Efficiency 4.406.1- Rodent Proofing - Annular spaces around pipes, electric cables, or other openings in sole/bottom plates at exterior walls shall be closed with cement mortar, concrete masonry or a similar method acceptable to the enforcing agency to prevent passage of rodents. 4.408.1- Construction Waste Reduction of at least 50% - A minimum of 500% of the construction waste generated at site is diverted to recycle or salvage. 4.408.2 Construction Waste Management Plan - Submit a construction waste management plan meeting items 1-5 in Section 4.408.2. Plans shall be undated as necessary and shall be available for examination during construction. 4.408.3 - Waste Management Company - Utilize a waste management company, approved by the enforcing agency, which can provide verifiable documentation that diverted construction and demolition waste materials meet the requirements in Section 4.408.1. 4.408.4 - Waste Stream Reduction Alternative - Generate a total combined weight of construction and demolition waste disposed in landfills that is equal to or less than 4 lbs per sq. ft. of the building area. 4.408.4.1- Waste Stream Reduction Alternative (High -Rise Residential) - Generate a total combined weight of construction and demolition waste disposed in landfills that is equal to or less than 2 lbs per sq. ft. of the building area. 4.410.1- Operation & Maintenance Manual - An operation and maintenance manual shall be provided to the building owner or occupant. Environmental Quality 4.503.1 General - Any installed gas fireplace shall be a direct -vent sealed -combustion type. Any installed woodstove or pellet stove shall comply with US EPA Phase II emission limits where applicable. Woodstoves, pellet stoves, and fireplaces shall also comply with applicable local ordinances. 4.504.1 Coverings of Duct Openings and Protection of Mechanical Equipment during Construction - Duct openings and other related air distribution component openings shall be covered during construction. 4.504.2.1- Adhesives, Sealants and Caulks - Shall be compliant with VOC and other toxic compounds limits. 4.504.2.2 - Paints and Coatings - Shall be compliant with VOC limits. 4.504.2.3 - Aerosol Paints and Coatings - Shall be compliant with product weighted MIR limits for ROC and other toxic compounds. 4.504.3 - Carpet Systems - Shall be compliant with VOC limits. 4.504.4 - Resilient Flooring Systems - 80% of floor areas receiving resilient flooring shall comply with the VOC - emission limits defined in the Collaborative for High Performance Schools (CHPS) Low -emitting Materials List or to be certified under the Resilient Floor Covering Institute (RFCI) FloorScore Program. 4.504.5 - Composite Wood Products - Particleboard, medium density fiberboard (MDF) and hardwood plywood used in interior finish systems shall comply with low formaldehyde emission standards. 4.505.2 - Concrete Slab Foundations - A vapor retarder and capillary break is installed at slab on grade foundations. 4.505.3 - Moisture Content of Building Materials - Wall and floor framing materials shall be checked before enclosure. 4.506.1- Bathroom Exhaust Fans - Exhaust fans which terminate outside the building are provided in every bathroom. 4.507.2 - Heating and Air Conditioning System Design - Duct systems are sized , designed, and equipment selected using the following methods: 1. Establish heat loss and heat gain values according to ACCA Manual J or equivalent. 2. Size duct systems according to ACCA 29-D (Manual D) or equivalent. 3. Select heating and cooling equipment according to ACCA 36-S (Manual S) or equivalent. Installed & Special Inspection Qualifications 702.1- HVAC system installers are trained and certified in the proper installation of HVAC systems and equipment. 702.2 Special inspectors must be qualified and able to demonstrate competence to the enforcing agency in the discipline in which they are inspecting. 703.1- Documentation - Verification of compliance with the code may include construction documents, plans, specifications, builder or installer certification, inspection reports, or other methods of acceptable to the enforcing agency which show substantial conformance. TABLE 4264 i ADHESIVE VOC LIMIT1�2 bws Watm and Loi ; Ewvnt GoviDoundg in Grams IterLitar ARCHITECTURAL APPUCATIONS CUPP ENT VOC LIMIT rni_vrcatr . ryt adhesives 15 Ca 't fad adhlAws 5711 Outdoor came[ adhesio 150 XVt1od flcv-rinp adhc,hv 1170 Rubber fly-fk1r adht s'ke s 45) Suhfloor a11vi;ia : Ceramic lit`> a+dhc--lives 6S VC7 and as Philt tilt as.] h,? si,.vs 250 775 Dywall arty pand aUh i cs � Ca hwr�i adhkt--ir.,%s 701) Afulti P u wky,, ccon str u c t i o ni ad h t -s i SCO Stnictiursl plarinT adhesi,ays Ico Si rLffIc- l r" -)C meinbrar#2! i li L, iiyw s 250 tact' i1kwive- no S -cifl ll" li:;tr_tfi 50 SPECIALTY APPLICATIONS R. PVIC Webdilw+-` 1-510 CP'VC7 dLJli , 4`tR ABS wc,,Iding 325 Plasties. cemsmt weldi n2 1250 Adllcsiv, .rimcrFor ,1.istic :550 4®«r7t tii adhoiyv Eire resistive conticips 350 Strua iral wood rnewheradh-csive ldtl 7op and Lfirm adhesive 250 SUBSTRATE SPECIFIC APPLICATIONS 2 Nft u o Metal T1 Plastic fr arns f" Porous matcrial (except w o. -Kid) _i! 1nda-,T,riai maintenana,cm, tin -s RK,mlt t Fo3 1- If an adht :sis-e is u w d to "_ id di ssi milar substrates on -g- ber. the udtk siv with the highest. NniCcontent shall'tc- ails+%vd. . 2. Fi`-�radditional information rcgnlding miethods ton>rza°suretheVOC content specified in this ta.blL, see Scxuth Ccaa t .fir Quality l4inriaagenx intlOistrict Ruler I11,6R. TAD LE 45 04,2 SEALANT VOCs LIFAI Less V`hter rand Loss: Exempt Compounds ht Grams Per Liter SEALANTS CURB ENT VOC LIM IT EFFECTIVE FLnt ivati-nLs Marini- deck 7(+ Non niembrane: mf 950 it I Rnadt,�► ' `r�� Sin -ale -ply ro.-I m embra riL 45) Other 42�r SEALANT PPIIAERS 0 Architectuad Non rxxous Pnrous 250 775 N16dif d hitlu9tUiiov 570 Nia ri ni d+ & 701) Cather 1 7%) TA OLE, 4504.3 VOCE CONT LIFAITS FOR ARCRTEC 1 UR',AL G T GSA3 Gmm-,s of for L[tetr ctf Go�lting, Liess Water and Lns Exempt Com, noutids COATING CATECOPY EFFEC17VE EFFECTIVE FLnt ivati-nLs Hardwogd .lywwvl %x lm ib; cofv 0.Q6 1q ,mflat i'. artn'"s 950 it I i~•iMiarn meta, itv ribe rlrxard N,Nnti:1t-hi ,h gtAs-c 6n p s ISO 0.1; SPECI ALTY CCAT1NGli r' Alu mi nu m roof co atines 0 Ba wrneat s : ci alt -jf Coal s 4111113 Brtunxtnouq.rooTconfrna15 so IBitunyiflous roogf rimers 3-5, Q Pend bx ak rs 350 Coflw l4 alrinfi M; fl pou it& 393 R. Cdoncir te.tmnscnry 1 Drib-etwra - s&alers 50 Dry fc , onatinm 1 150 Faux fiaishi Cnalings + Eire resistive conticips 350 Fi{a+ r'sarat Ica R-Ym-felea COM . au flds 2 GrD liis arr tirips (Si n ints'i 5(07) [ft prh tent It era tu re cmtirlos 429 1nda-,T,riai maintenana,cm, tin -s 250 Lnw:a)tids crotiriosi iY Ma n•-citoc-ernent coatinE£ 49.) Niviz texoxe coatin s 1�, Ment)I1i,t i,? .ft trtM mati ngs Sri) 14 ultictll--t 07".1602 s 250 Pretreatirientwash pjrimers 421 Mirk :rs, :allaJe�fx, aLTJktnillerC it t 1ft,J Re active 'irk* ali n: sealk'rs 3 R,: cw1od c; minv? 2 FL-*1fcce fin . 1 Rust All) 2511 Sh•Atw!S Clear Op u ue T3* 550 S \-In1r-' +rime ti. sea lets aixt n 39) 1 rin St,tills 250 _Strim c. molidrinl 45-0 swimirr ucip, rooI coati HP,5 HP, 340 Traffic. mad6fi ,c*atin ;s 100 Tuff and rile ref Oish cbari u s 42)1 Walerpirorfim lmerribrwier, ? Wood contir-Ges 27i 'WQ?d y1III 4y girl;,'' -Lich prifnesN, 1 t. Grams of'VOC I r liter of coatini . including i&-ater and irtcludiq� exempt . 7bespc:ifitedIin itsremain ineffect unl .i re,#i!o,_,dAmiis3reIisittx-lins.ih-;e quent colrum ns in tb--, table. 3. '54alues in this table arra derived from those SPkX1ifvd by th- C3:li16niia Air ?c rrce 13aarci, Architectural Coatings Su osti onto 1 Nfoastf r-ebruxn, 1, 2008. Mire inf4matioin is avail able rrorn the Air re���urces la'oard. TAB £ cf>o4z i-ORMALUEE DE LIMITS1 Maximum EoI maldehvcle Emissions In Fouls Der Llillion PPQDLIU CLI''RRE"T WAIT Hard -Nood plN-A,ond-wneercctre. 0.{+� Hardwogd .lywwvl %x lm ib; cofv 0.Q6 Ptittic: hboard 0.0) i~•iMiarn meta, itv ribe rlrxard 0.11 'titin Lino iuim don sitv Iiil7r d' 0.1; 1. Valuc5 in 'thi- tAN-2 ary d°riw-J fft,In thtl c %.pc:i:fi-A by the Cali Rim ii. Air Reurrcv% Board. ,fir Toxics C'•-ntrol h4easum for Composite Nonacid as teste7dt.n'accordanee -with r'sSTh1 E 1333. For add itionc-1 inf6troatie-In,sce« Ccr ,for#iftCcrdeqrRegralt de -tor Titre 1',Vic,Lians9.31_20through9.,120.12. 2 TI-dnm,2dium & mity11K,arrt•:_td h sa ma-xiniurnthic1mesxof 5�.imb (8rnm'). REVitwtu FOP. CODE COWLIANCE .IAN 17 2017 [NTERWEST CONSULTING GROUP NOTE: THE PROJECT MANA6ER OR GENERAL GONTRAGTOR WILL BE THE RESPONSIBLE PERSON TO COLLECT AND PROVIDE VERIFICATION OF GALGREEN GOMPLIANGE TO THE BUILDING INSPECTOR PRIOR TO BUILDING SINAL. Revision: Date: By: Sip AR�y �00 aY ic Na. C 21M;A Np -7 1(� RESIDd�TIAL GALGREEN MANDATORY MEASURES Date 2016 Scale Drawn Job 6 U) Cid 0 0 N 011N N .a r' - R. vK Sip AR�y �00 aY ic Na. C 21M;A Np -7 1(� RESIDd�TIAL GALGREEN MANDATORY MEASURES Date 2016 Scale Drawn Job 6 U) Cid 0 0 N 011N N .a r' �r i