Re: Swimming pool at the Krawec Residence, 4127 Tiberon Way, Chico, CA
Dear Mr. Hunt
Please allow Agua Fina Pools to utilize Pool Engineering Standard Pool Plan for
permitting and construction of the pool at the above referenced address.
If you require any additional information or if I can be of any further assistance,
please don't hesitate to contact me at (714) 630-6100.
Best rt7--
Greg
Pool Ron Lacher
Pool Engineering Inc.
1201 N. Tustin Avenue, Anaheim, California 92807 Fax: (714) 630-6114 Phone: (714) 630-6100
ANTI -ENTRAPMENT CERTIFICATION FORM
FOR SWIMMING POOLS & SPAS
FO_
The following form is required whenever a building permit is issued to construct
or repair (re -plastering) a swimming pool, toddler pool, or spa.
STATEMENT TO BE SIGNED PRIOR TO
FINAL APPROVAL
Verification of Compliance with the "Swimming Pool Safety Act of 2006"
(Health & Safety Code 115920 —115929)
Site Address:
Property Owner:
Owner's Mailing Address:
Phone:
I hereby certify that the swimming pool, toddler pool, or spa located a the above-
mentioned address complies with the provisions or the "Swimming Pool Safety
Act of 2006" and has been equipped with an anti -entrapment cover meeting
the current ASME/ANSI Standard A 112.19.8 as required under the
provisions of the law and have received additional information on pool
barrier requirements.
Signed:
Signed:
Owner
Contractor
Company Name:
Date:
Date:
CONTRACTOR'S INFORMATION
California Contractor's License Number:
Mailing Address:
Phone:
Email:
Attachments: Swimming Pool Enclosure Requirements and Pool Barrier handout
Page 1 of 3
Swimming Pool Enclosure Requirements
Definitions
Approved Safety Pool Cover: A manual or power -operated safety pool cover that meets
all of the performance standards of the American Society for Testing and Materials
(ASTM), in compliance with standard F 1346-91.
Enclosure: A fence, wall or combination thereof that isolates a swimming pool
from unauthorized access.
Exit Alarm: A device that makes an audible, continuous alarm sound on the doors
leading from the dwelling/garage or other structure to the pool enclosure, which, when
opened or left ajar, permits entry to the pool without any intervening enclosure device.
Exit alarms may be battery operated or connected to the electrical wiring of the
building.
Public Swimming Pool: A swimming pool operated for the use of the general public
with or without charge, or for the use of the members and guests of a private club.
Public swimming pool does not include a swimming pool located on the grounds of a
private single family dwelling.
Swimming Pool or Pool: Any structure intended for swimming, recreational bathing or
other recreational use that will contain water over 18 inches in depth. Swimming pools
include in -ground and above -ground structures and include, but are not limited to, hot
tubs, spas, portable spas and non-portable wading pools.
Other terms, words, or phrases not defined shall have their ordinarily accepted meanings
within the context with which they are used. Webster's Third New International
Dictionary of the English Language, Unabridged, copyright 1986, shall be considered as
providing ordinarily accepted meanings.
PPwi-,4P€g 7 ')n1 Page 2of3
Swimming Pool Requirements
Drowning Prevention Safety Features
Based upon California Health and Safety Code Section 115920-115929, known as the Swimming
Pool Safety Act
The County of Butte requires either a listed, approved safety pool cover* meeting
ASTnf Standard F1346-91, OR a complying enclosure* which isolates the pool from
the dwelling and remaining yard,
OR a complying enclosure* which surrounds the perimeter of the pool and dwelling, with door
alarms and self-closing, self latching devices on all doors leading into the enclosure.
*Enclosures
• Minimum height of 60 inches
• Access gates shall open away from pool and have self-closing, self -latching device no lower
than 60 inches above the ground.
• Maximum vertical clearance of 2 inches from the ground to the bottom of enclosure
• No openings greater than 1/2 inch within 18 inches of the release mechanism when closed.
Gaps or voids shall not allow the passage of a 4 inch sphere.
• Outside surface shall be free of cavities or protrusions that would serve as a foothold or handhold
that could enable a child of less than 5 years of age to climb over.
• Maximum mesh size for chain link shall be a 2.25 inch square unless the fence is provided with
slats fastened at the top or bottom which reduce the openings to no more than 1.75 inches
*Pool Cover
• Shall be correctly installed per the manufacturer's instructions to prevent the access of children
under five years of age to the water.
• Shall be properly constructed to meet ASTM specifications and be labeled accordingly.
• All ties, anchors or attachment points and controls for automatic covers must be installed in a
way to prevent operating or uncovering the poll by children less than five years of age.
• The pool cover shall possess a listing that insures the original design or performance of the cover
meets. or exceeds testing as prescribed by ASTM Standard F1345-91, Section 9 Test Methods for
Safety Covers.
Door alarms or self -Closing,
self -latching doors
VVIndcwvs and doors
routinely closed and rvw
latched _
*Safety pool
caner,n,, � V
10 lij �J'
self-closing,
sett latching
ht a minimum, one ofttme shatiibe provided
(Reosed 4/03)
vi -,pr 7_20,2M.5 1.2M.5 Page 3 of 3
WATER SUPPLY AND DISTRIBUTION
130 2013 CALIFORNIA PLUMBING CODE
WATER SUPPLY AND DISTRIBUTION
TABLE 603.2
BACKFLOW PREVENTION DEVICES, ASSEMBLIES, AND METHODS (continued)
DEGREE OF
TABLE 603.2
BACKFLOW PREVENTION DEVICES, ASSEMBLIES, AND METHODS
CONTAMINATION
DEGREE OF HAZARD
�
I (HIGH HAZARD)
POLLUTION 7 CONTAMINATION
-
DEVICE, ASSEMBLY, APPLICABLE
(LOW HAZARD) (HIGH HAZARD)
--
I INSTALLATION 47
OR METHOD' ' STANDARDSBACK"
_ - BACK- BACK -
- -
SACK
Pressure Vacuum
SIPHONAGE PRESSURE
SIPHONAGE { PRESSURE
( {
ASME
,Air a
X — X —
I See Table 603 3.1 in this chapter.
i
AASME2
I
air inlet ASSE or —
X
I
I
Air gap fitting is a device with an inter
Air a fittings for use !
I
nal air gap and typical installation
plumbing
with lumbin fixtures, ' A]12.1.3 .
X ! — X —
Iincludesplumbing fixtures,appliances
appliances and appune•
PPS nances. The critical llevell
nances
f
nudl be installed below the flood rim.
(Atmospheric vacuum
1
i Upright position. No valve down -
I
'breaker (consists of a body,'( ASSE 1001 or
X — X I _
stream. Minimum ot6 inches or listed
,checkingmember and CSA 864.1.1
!I
!distance above all downstream piping
atmospheric port)
,
i
,and flood level rim of receptor.4•s
X X
— _
4 or
valves, a differential CSA B64.4
(
once at bottom for maintenance. May
j Y
Installation on gravity water closet
lAntisiphon fill valve (ball-
I
I
and means of field !
testing)
I
flush tank and urinal tanks with the fill
icocks) for gravity water
ASSE 1002 or I
X
— X I —
valve installed with the critical level notll
closet flush tanks and url- I
CSA B 125.3
less than 1 inch above the opening of
!nal tanks
I
!the overflow pipe." I
I
_ _ I
• Installation includes will hydrants and
Vacuum breaker wall
'hydrants, hose bibbs, frost ASSE 1019 o r
I
hose bibba. Such devices are not for use
:
X
—
X —
under continuous pressure conditions
.resistant, automatic dram CSA 864.2.1.1 I
(means of shutoff downstream of
ling type
I
(device is prohibited) 4.1
IBackFlow preventer for !
!
Installation includes carbonated bever-
'',Carbonated Beverage Dis•
1pensers (two independent J
ASSE 1022 I
X
— —
—
age machines or dispensers. These
devices intermittent or
;check valves with a vent to
I
I
I
operate under
!continuous pressure conditions. '.
the atmosphere) _
----�'
----- � �-_ I-
---
�-� -- .---` i-_
'Spill-Resistant
!S Ill Resistant Pressure
P
i..._
ii
Vacuum Breaker (single
n—
check valve with au inlet
ASSE 1056
X I
—
X
Upright position. Minimum of 12 inches
or listed distance above all downstream
ventand of field
piping and Flood -level rim of receptor.'
:testing)
i__..._ .._..._.
_. ._.._.— _
__..__.
_ ......_._. _ ..._. __._ ------ ----
! i
1 Horizontal unless otherwise listed.
Double Check Valve Back-!
I
Access and clearance shall be in accor-
flow Prevention Assembly
:
dance with the manufacturer's instruc-
((two independent check
i AWWA C510;
X
X — —
tions, and not less than a 12 inch clear-
'vaives and means of field
CSA B64.5 or I
I I
'once at bottom for maintenance. May
hating)
i CSA 864.5.1 1
I
need platfomJladder for test and repair.
I
Does not discharge water.
!Double Check Detector
Horizontal unless otherwise listed
(Fire Protection Backflow
I
Access and clearance shall be In accor-
! dance with the manufacturer's instruc.
!Prevention Assembly (two
Iindepcndent check valves!
'tions, and not less than a 12 inch clear -
with a parallel detector
i ASSE 1048 I
X
X
j —
—
once at bottom for maintenance. May
nod platfomVladder for test and repair.
assembly consisting oCa
meter and a double
i
Does not discharge water, Installation
(water
(check valve backflow pre-
I I
includes a fire protection system and is
assembly and
I
I
designed to operate under continuous
ivention
.means of field testing)
l l
--
pressure conditions.
130 2013 CALIFORNIA PLUMBING CODE
WATER SUPPLY AND DISTRIBUTION
TABLE 603.2
BACKFLOW PREVENTION DEVICES, ASSEMBLIES, AND METHODS (continued)
DEGREE OF
HAZARD
POLLUTION
I
CONTAMINATION
DEVICE, ASSEMBLY, ' APPLICABLE (LOW HAZARD)
I (HIGH HAZARD)
INSTALLATION 2 a
! __
OR METHOD STANDARDS BACK BACK-
.._ _. _..)
� BACK- -BACK.
;
I. SIPHONAGE I PRESSURE
-
1 SIPHONAGE , PRESSURE
_
j
Pressure Vacuum
!.
Breaker
j
1(loaded
Upright position. May have valves
-
Prevention Assembly
ntio
1020
(
downstream. Minimum of 12 inches
i
air inlet ASSE or —
X
X —
above all downstream piping and I
valve, internallyCSA B64.1.2
loaded
(Flood -level rim of receptor. May dis- i
check valve I
I
charge water.
Iand means of field
'testing) ..
Reduced Pressure
Principle BackflowI
1
I
Horizontal unless otherwise listed
Prevention Assembly ASSE 1013; !
Access and clearance shall be m actor•.
(two independently AW WA C51 I; I
1
I
1 dance with the manufacturer's mstmc-
acting loaded check X X
X X
1; tions, and not less than a 12 inch clear.
4 or
valves, a differential CSA B64.4
(
once at bottom for maintenance. May
j Y
pressure relief valve CSA
need platform/ladder for test and '.
and means of field !
testing)
!
repair. May discharge water.
For SI units: I inch - 25.4 mm
Notes:
I See description of devices and assemblies in this chapter.
= Installation in pit or vault requires previous approval by the Authority Having Jurisdiction.
Refer to general and specific requirement for installation.
4 Not to be subjected to operating pressure for more than 12 hours in a 24 hour period.
s For deck -mounted and equipment -mounted vacuum breaker, see Section 603.5.14.
Horizontal unless otherwise listed.
Access and clearance shall be in accor-
dance with the manufa rtuer's instruc.
tions, and not less than a 12 inch clear -
X ante at bottom for maintenance. May
need platformlladder for test and
repair. May discharge water. Installa-
tion includes a fire protection system
i and is designed to operate under con-
tinuous pressure conditions.
,
I �
C—A—
V
�E 1JC E L .
\3 �G GCrt
flo
G IV c,... t
t / L—
x �
NOTE: swimming pool shall comply with -
S►rimmingPoci Se6C,Act of2006 & CA
Health and Safety CO Sections t7-
' IS >1592
Complete Anti-E►rtrapment Certification Font.
Provide to building inspector prior to final inspection
t'
NOTE:
a See the attached
t�
Swimming Pool Requirements
brimi-L tic moIALltu Aa veouwncV In into ►vt n
CEC 680.26
EQU:POTENTiAL BOND BONDED PARTS
680.26(13)(1) THROUGH (7) SHALL BE BONDED
TOGETHER BONDING
BUILDING MASTER PLAN
PERMIT#L -13)j # q-(017
ASSESSOR'S PARCEL#L A O-�x
JUAN 16 2016"
SERVICES
CONSTRUCTION SPECIFICATIONS
1. EXCAVATION AND RELATED SPECIFICATIONS
Comply with current California Energy
CASH
CEC 680.260 EQUIFOTENTIAL BONDING GRID
Commission requirementsforimming
equipment, Plumbing
)
L�
SHAD. BE INSTALLED AS DESCRIBED BY THIS CODE—THE
GRID SHALL p(TEND UNDER PAVED
pOOIS, pool
heating equipment
Depth to
EQUIPOTENTIAL BONDING
WALKING SURFACES 3–FT HORIZONTALLY BEYOND THE INSIDE
and
_
WALLS OF THE POOL.
Perimeter Ft.
Qj
Dk1 on Job Site s ' Left
An mAdoor swimming pool shall G,Y prur6i o, tri`It
:; Shrubs :" Trees
SquareFt
ding prevention €afety features tF ' edit ply with
1s,
Deep end ramp .:
Califon, la Health and Safety Ca."; Vc;, yen 115320-
Equipment slab
x
11.'t'A. These features shall be n.-ispected
Footings Ft. at $ per Ft.
Elevation ���_
and z:% -roved prior to plastering or fi`.IV-3 with water.
Removed by: Buyer ;'
Contractor .;
Pool Capacityc�Gals.
Pool cover
_
Separate Mechanical Permit
r
Filter rate 7 G.P.M.
required for the installation of
i
Aim flow(s) #�
a swimming pool heater
Tum over Hrs.
Ft. of rope wt boats �::
Skimmer(s) If_�-
rt
BUILDING MASTER PLAN
PERMIT#L -13)j # q-(017
ASSESSOR'S PARCEL#L A O-�x
JUAN 16 2016"
SERVICES
CONSTRUCTION SPECIFICATIONS
1. EXCAVATION AND RELATED SPECIFICATIONS
BANK `'
CASH
Pool Size x
0 f
-
Access width
Maintenance kit (To include the following) :.
Remove from site, day of excavation only:
Depth to
Excavation (Type}
_
:::: Concrete :;? Asphalt. Stumps
Perimeter Ft.
_
Dk1 on Job Site s ' Left
Removed
:; Shrubs :" Trees
SquareFt
�
Shallow end ramp
Deep end ramp .:
Retaining Walls (Type)
Equipment slab
x
Site aocess '; Wall :. ; Fence to be:
Footings Ft. at $ per Ft.
Elevation ���_
indoor ; . Outdoor: ,
Removed by: Buyer ;'
Contractor .;
Pool Capacityc�Gals.
Pool cover
_
Replaced by: Buyer :_;
Contractor:.,:
Filter rate 7 G.P.M.
Miscellaneous
Rope Anchors #
Aim flow(s) #�
Vacuum :.: _ _
Tum over Hrs.
Ft. of rope wt boats �::
Skimmer(s) If_�-
2. EQUIPMENT
Filter
Sq, Ft. ':
Maintenance kit (To include the following) :.
Grab rail panels
Backwash valve _
Brush Leaf skimmer Test Kit ::
Lfght(s)# with Ft.cord"
Pump horse power
`:
16 Ft pole ::' Thermometer ::_
300W ::: Trans.:-: 40OW :: 5WW M
Separation tank
Chlorinator
Color Pak
Heater _ BTU
VvingiJump Board Ft "
_
Time Clock(s) Model #
Nat ... LPG ... Elea.... Oil ...
Solar <_ .
Diving Board Panels
G. F.1.
indoor ; . Outdoor: ,
Slide (type)
Booster pump to H.P.
Pool cover
_
--Color
Sir..Cur. ....Left .. Right :.
.-
Prevent -a -Freeze__
Automatic Pool Cleaner
Rope Anchors #
Aim flow(s) #�
Vacuum :.: _ _
R. hose
Ft. of rope wt boats �::
Skimmer(s) If_�-
Grab rails
Main drain(s) #
Miscellaneous
3. PLUMBING PVC COPPER .
Fill lineFt. of Backwash Ft. of Solar Ft of
Slide _ A. of Drain line Ft. of Overflow Ft. of
Return Ft. of Pool Cleaner _ Ft. of Fountain _ Ft. of
Suction_ Ft of
Miscellaneous
4. STRUCTURAL
Steel Schedule _ Deep End Ramp :.: Shallow end ramp .:
Miscellaneous
5. CONCRETE
Equipment slab___________ x Swimout Ft. Inside .: Outside
Custom steps Recessed Steps _
Miscellaneous
6. TILE AND/OR COPING CANTILEVER 7. GAS LINE
Tile # _ Color Builder Utility Owner :"
Size_ Line size _
Coping # _ Color - Line (meter to heater) _ _ Ft.
Rock : ; Type y Ft. Ft. included additional at $_--per
Miscellaneous Miscellaneous
8. ELECTRICAL
Builder • Utility Owner Elee. run (Panel to equip.) _ G. F.I. Time Clocks)
Miscellaneous _ Ft included additional at $. per Ft. light switch loc.
9. DECKING
Builder Utility : Owner Type_
Sq. Ft. Color _ Cantilever
Miscellaneous
10. INTERIOR FINISH
Std.Color
'i
_ w _
Main drain vortex Anti vortex
Miscellaneous
Office_._�1
Phone -5 --
Office
Office use only
11, START UP
Service
Initial treatment only_
W
Exp. joints: Fell Brick Wood
W/Cap laterals
Mastic—
Dividers
phone-—.----' -.-
PLAN APPROVAL
Signihlre indicates owners approval of pool andtor spa and equipment locations plus all accessories listed herein.
OWNER: SALESMAN:
OWNER: _ DATE:
OTE: DIVING N
BON BOA
POOLRD GTO BE INSTALLED ACCORDING TO MANUFACTURERS INSTRUCTIONS AND
OWNER WATER ACCESSTO ATER DOWN POOL SiTE AREA — DAYS PRIOR TO EXCAVATION.
NOTE: 0 NOT
140TE: AN ELECTRICAL BONDING INSPECTION MUST BE APPROVED PRIOR TO POURING DECKS.
NOTE; NO DIRT WILL BE REMOVED, RETURNED OR GRADED AFTER DAY OF EXCAVATION.
DUDIPM N T AD ATi0 OWVED NER OR THIS LOCATION ONLY — RELOCATION WILL RESULT IN
NOTE: A
1' 0TE: EXTRA COND°UIT ATTTiMMOVED IF INSTALLATION. O PAY ELECTRICIAN FOR
OTE: ONCR ETE DECK
SPECIFICATIONSMUST BE ARATED FROM POOL STRUCTURE IN ACCORDANCE WiTH
OWNER
TO FENCE POOLAREA AND INSTALL SELF CLOSING AND SELF
LATCHING GATES PER COUNTY OR CITY ORDINANCE.
OWNER
TO REMOVE OR HAVE RELOCATED ANY OVERHEAD
ELECTRICAL WIRES PER COUNTY OR CITY ORDINANCE.
OWNER
TO T DOWN CONCRETE SHELL AT LEASL3—TIMES DAiLY
FOR DAYS.
DO NOT TURN ON POOL LIGHT WHEN POOL IS EMPTY.
DO NOT USE RUBBER HOSE WHEN FILLING POOL AS IT WILL
MARK INTERIOR FINISH.
"AWARD WINNING
POOLS,
Agua fina Pools
:1
Contractor's License No. 942647
V � O
b ¢.r
4il �i ,te o.�
of 613 73
1fJ,
.- t
k -
P REVIE ED
/fowon rma ce t raI details
Jeffffery. Collins R.C.E. 80733
P of Engineering, Inc.
Stnoural detells shall take precedence over conflicts with site pian.
PERMIT #
BUTTE COUNTY DEVELOPMENT SERVICES
REVIEWED FOR
DATE % 6 BYE_ ECE
�! D-.__--
BUTTE
COUNTY
JUN 16 2016
DEVELOPMENT
SERVICES
); ) J�Y3p-
BENCH AND STEP OPTIONS: SLOPE EARTH SURFACE 1/4" PER NOTE: TABLE NO. 1 GENERAL NOTES GLAZING IN HAZARDOUS LOCATIONS
BOND BEAM HORIZONTAL BARS MAY BE
J L UNDISTURBED EARTH MAY BE LEFT IN PLACE TO FORM THE STEPS OR BENCHES. REINFORCING STEEL FOOT OR SLOPE DECKING 1/8" TO OVER OR UNDER VERTICAL BARS.
SHOULD BE PLACED AROUND THE STEP OR BENCH SHAPED EARTH (3' CLEAR FROM EARTH). 1/4' PER FOOT AWAY FROM POOL TYPICAL INCLUDING ALL SPECIAL DETAIL
2. THE EARTH MAY BE REMOVED AND BENCHES AND STEPS MAY BE FORMED OF SHOTCRETE (GUNITE) WITHIN
THE STRUCTURAL POOL SHELL REINFORCING AT THE SURFACE OF THE BENCHES AND STEPS IS OPTIONAL. 2 STORY WOOD APPROVED SEALANT RECOMMENDED (PER
FRAME BUILDING DETAIL 18). REQUIRED W/ EXPANSIVE SOIL.
TABLE 1 TABLE 5 _ BASIC GRID #3 1500 #/FOOT MAX. COPING
BARS O 12" O.C.
DRAIN BOND BEAM
DECKING. MINIMUM A TABLE TABLE TABLE WATER SURFACE. +- -• SEE TABLE #1 & DETAIL #12.
WIDTH PER LOCAL B Q APPROX. 3" BELOW
`Y BOND BEAM. vn nwv
BUILDING CODE. '" f 'Wi a •• N
C 3'-0" MIN. ¢
r7
H
M COPING
NO R.B.B. I c- M 0 3` LO
a o
'n ¢ n s m un ,rvrurt r v s Z CLR. X o
M _� o BENCH/STEPS - - - -
rte___. ._._. _.._. __. I - - ^ a SEE OPTIONS 1 a a
ABOVE 1 �� UNDISTURBED SOIL tO o N
r �' I N F 1500 PSF MIN.
¢ ' r J BEARING VALUE.
--------_ ______� _.._......
I E.�
N INFLUENCE LINE 1
�1 '
UNDER- -- - FOR FOOTING 'C SHOTCRETE COVER
WATER i SURCHARGE TO BE CHANGED t •d p� Q0
LIGHT PERa, ,,,,, UNIFORMLY.
DETAIL 10. _, __ -- ----" SEE TABLE 1 t
# I _ I �j-tADD #3 O12" O.C.
5 -
STEEL
.TRANSITION ACTUAL DIG LINE MAYS
FOR EXP. S01
- • ' VARY, LOCATE STEEL
TYP. FLOOR 3" CLR FROM EARTH ` 0
STEEL BASKET IS NOT REQUIRED �l l" SURCHARGE CONDITION: - - -
� - 6" THICK MIN. SHOTCRETE (GUNITE) VERTICAL STEEL
DRAIN PIPE SHALL NOT W/ #3 BARS ® 12" O.C. s-• �S� TABLE 1 SCHEDULE 'D', SEE TABLE 1 S 24" MIN.
_(BUILDING SURCHARGE MEN
ENCROACH INTO GUNITE SHELL EACH DIRECTION SETBACK TO BUILDING) FOUNDATION HORIZONTAL STEEL ~' REINF INTO FLOOR.
CIRCULATION DRAINS: IN HIGH WATER TABLE, INSTALL . 'W IS LESS THAN POOL DEPTH. #3 BARS O 12' O.C. (30' MIN. FOR TABLE 5G)
PROVIDE (2) ANTI -VORTEX SUCTION OUTLETS PER PUMP, HYDROSTATIC VALVE AND ROCK' e
COVERED WITH APPROVED A.S.M.E. STANDARD A112.19.8 PACK AT LOW Pnl T.- ' ' (6' HIGH MAX. FREESTANbING, ADDITIONAL BARS BEGIN AT 5'-0" FROM THE TOP OF THE POOL
ANTI -ENTRAPMENT GRATES, THAT ARE HYDRAULICALLY`'- MA ONRY SCREEN 0 GARDEN' .f..
WALL (RAISE) OR NOT RAISED)
S.
NON -EXPANSIVE
EXPANSIVE
NO DECK/HIGH EXP.
BUILD'G SURCHARGE
A
B
C
D
io
(3) j3 BARS.
io
(4) 13 BARS.
io
v
io
E.F.P.
30 P.C.F.
45 P.C.F.
65 P.C.F.
45 P.C.F.'
D R
C
VERTICAL
STEEL
C
VERTICAL
STEEL
C
VERTICAL
STEEL
C
VERTICAL
STEEL
3'0' 1'-0"
3"
#3 ® 12"
3"
#3 O 12"
3"
#3 O 12"
- - - -
3"
#3 O 12-
3-6- 1'-0"
3"
EXPANSION. WEATHERPROOF OPERATING INSTRUCTIONS ON ENERGY EFFICIENT OPERATIONS, NO
3"
6. ALL CONSTRUCTION SHALL COMPLY WITH THE 2013 EDITIONS OF THE CALIFORNIA ELECTRIC RESISTANCE HEATING AND NO PILOT LIGHT.
3"
3"
4'0' V-0"
3"
ALL SWIMMING POOL AND SPA FILLERS PER CPC 603.4.22
3"
- -
4"
- - -
4-
4-6- V-0"
3•
----
3'/z'
----
5'----
6"
10.CONTRACTOR HIGH FENCING &GATES WITH NO OPENINGS GREATER THAN 4". GATES TO BE
OWNER SHALL VERIFY ALL FIELD CONDITIONS SI DIMENSIONS AT JOB
5'0" V-6'
3"
#3 06-
- -
4"
#3
-
® 6"
- -
5"
#3 O 6"
- - - -
5"
#3 O 6-
-
-
-
T
5-6- 2'-0"
3•
4"
5"
5�%'
6'0" 2'-6"
3"
4"
6"
5�%'
6'6" 3'-0"
3"
4%'
7'
6%'
7'0" S-6"
3"
- -
1 O
5"
8"
7�%'
--
---
9"--
--
9.
11'0" 9"
8'0" 4'-6"
3"
6"
13'
-
10"
----
8'fi"
8.6" 5'-0"
3"
6"
-
10"
- -
- -
8�/Z"
INDICATES TYPICAL RADIUS (ACTUAL RADIUS NO DECK OR HIGH
MAY VARY, SEE STRUCTURAL NOTE #11) EXPANSIVE SOIL
1. THIS STANDARD POOL STRUCTURAL PLAN MUST BE ACCOMPANIED BY A CLEAR PLOT WHEN REQUIRED BY THE BUILDING OFFICIAL, GLAZING SHALL COMPLY WITH THE CBC SECTION
PLAN SHOWING POOL & OR SPA SHAPE, DEPTH AND DISTANCE TO PROPERTY UNE, 2406.4, INCLUDING LOCALLY ADOPTED AMENDMENTS.
EXPANSIVE
SLOPES AND STRUCTURES. 1. GLAZING IN WALLS AND FENCES USED AS A BARRIER SHALL BE SAFETY GLAZING WHEN
* IF POOL 'WALL HEIGHT DOES NOT EXCEED 5'-0" THEN NO ADDITIONAL
2. REPRESENTATIVES OF POOL ENGINEERING INC. HAVE NOT INSPECTED THE SITE & ARE ALL OF THE FOLLOWING CONDITIONS ARE PRESENT:
4. ALL EQUIPMENT SHALL BE LISTED AND INSTALLED PER MANUFACTURERS
RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL REGULATIONS.
RELYING ON INFORMATION PROVIDED BY THE CONTRACTOR OR OWNER TO DETERMINE A. THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60" ABOVE ANY STANDING OR
65 P.C.F.
THE ADEQUACY OF THIS STANDARD POOL STRUCTURAL PLAN FOR THE ACTUAL SITE WALKING SURFACE
VERTICAL
STEEL
CONDITIONS. SHOULD SITE CONDITIONS VARY FROM THAT COVERED BY THIS STANDARD B. THE GLAZING IS WITHIN 5 FEET OF A SWIMMING POOL OR SPA DECK AREA.
BARS ARE REQUIRED. (DOES NOT APPLY TO SUPPLEMENT DETAILS)
POOL STRUCTURAL PLAN, IT IS THE RESPONSIBILITY OF THE CONTRACTOR OR THE
5. POOLS SHALL BE EQUIPPED WITH A FILTERING SYSTEM & A DRAIN.
6. BACKWASH SHALL BE DISPOSED OF IN AN APPROVED MANNER.
OWNER TO NOTIFY POOL ENGINEERING INC. AND OBTAIN APPLICABLE SPECIAL CONTINUOUS SHOTCRETE INSPECTION
#3 012"
ENGINEERING DETAILS PRIOR TO CONSTRUCTION. EXPANSIVE SOIL DETAILS ARE VALID
#3 O 12"
ONLY FOR STATED EQUIVALENT FLUID PRESSURES AND POOL ENGINEERING INC. WHERE REQUIRED ALL PNEUMATIC CONCRETE PLACEMENT SHALL BE INSPECTED BY A SPECIAL
#3 O 12-
RECOMMENDS THAT THE OWNER OR CONTRACTOR OBTAIN A SOILS REPORT. INSPECTOR IN CONFORMANCE WITH CBC SECTION 1704, WHO SHALL SUBMIT A STATEMENT
7• POOL/SPA WATER HEATER AND GAS PIPING INSTALLATION TO BE IN CONFORMANCE
WITH THE CPC.
8 CONTRACTORIS ADVISED TOINSTALLATION REERTSECTIONOFTHECALIFORNIA HEALTH &
3. THIS PLAN IS NOT VALID WITHOUT ADDITIONAL SURCHARGE DETAILS WREN THE INDICATING COMPLIANCE WITH THE PLANS AND SPECIFICATIONS.
3"
3�%'
CONDITIONS AS SHOWN IN DETAIL J3 APPLY (PER CBC SECTION 1808.7.3). ALL POOLS TLE 24
2
SHALL COMPLY WITH SLOPE SETBACKS PER CBC SECTION 1808.7.3.
1
4. THE STANDARD POOL STRUCTURAL PLAN IS NOT INTENDED TO BE APPLICABLE TO 1. PUMPS SHALL BE SIZED PER SECTION 150(p) OF THE 2013 BUILDING ENERGY EFFICIENCY
3'%*
NON- STRUCTURAL ITEMS INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, STANDARDS.
5%*
FENCING, CONCRETE DECKING AND POOL GEOMETRICS. 2. MANDATORY REQUIREMENTS FOR POOL & SPA HEATING SYSTEMS & EQUIPMENT -
5'6" 3"
5. DECKING CONSTRUCTION IS SHOWN AS RECOMMENDED MINIMUM CONSTRUCTION AND 1.1. SYSTEM IS CERTIFIED WITH: THERMAL EFFICIENCY THAT COMPLIES WITH THE
SAFETY THE15928 POOL DRAIN
9. A REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER RP DEVICE IS REQUIRED ON
( )
DOES NOT DEMONSTRATE A SYSTEM THAT WILL RESIST HEAVING DUE TO SOIL APPLIANCE EFFICIENCY REGULATIONS, READILY ACCESSIBLE ON-OFF SWITCH,
5"
EXPANSION. WEATHERPROOF OPERATING INSTRUCTIONS ON ENERGY EFFICIENT OPERATIONS, NO
6-6- 4"
6. ALL CONSTRUCTION SHALL COMPLY WITH THE 2013 EDITIONS OF THE CALIFORNIA ELECTRIC RESISTANCE HEATING AND NO PILOT LIGHT.
TOE OF SLOPE OR OTHER
BUILDING CODE (CBC), CALIFORNIA ELECTRICAL CODE (CEC), CALIFORNIA MECHANICAL 1.2. SYSTEM IS INSTALLED WITH:
- - - -
CODE (CMC), CALIFORNIA PLUMBING CODE (CPC), CALIFORNIA ENERGY CODE, 2013 A) AT LEAST 36' PIPE BETWEEN FILTER & HEATER FOR FUTURE SOLAR HEATING.
ALL SWIMMING POOL AND SPA FILLERS PER CPC 603.4.22
BUILDING ENERGY EFFICIENCY STANDARDS, 2013 CALIFORNIA GREEN BUILDING B) COVER FOR OUTDOOR POOLS OR OUTDOOR SPA.
7'0" 5"
STANDARDS CODE, AND LOCAL ORDINANCES. 1.3. POOL SYSTEM HAS DIRECTIONAL INLETS & A CIRCULATION PUMP TIME SWITCH TO
SURCHARGE CONDITIONS
(SEE GENERAL NOTES #3)
7. POOLS WITH DIVING BOARDS SHALL MEET DIVING BOARD MANUFACTURER'S POOL PERMIT OFF PEAK OPERATION.
PROVIDE ADEQUATE DRAINAGE
BOND BEAM PER BEHIND POOL WALL
GEOMETRIC STANDARDS AND/OR LOCAL CODES.
FENCING
STRUCTURAL NOTES
1. SOIL SHALL HAVE A MINIMUM BEARING VALUE OF 1500 PSF CONCRETE SHALL BE
8. SIGNS & SAFETY EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH LOCAL CODES. AND BARRIERS
-
9. PUBLIC POOLS REQUIRE COUNTY HEALTH DEPARTMENT APPROVAL AND PROVISIONS FOR 1• PRIOR TO FILLING, THE POOL AND OR SPA SHALL BE COMPLETELY ENCLOSED BY 5' MIN.
ASSISTIVE DEVICES FOR THE DISABLED.
6"
10.CONTRACTOR HIGH FENCING &GATES WITH NO OPENINGS GREATER THAN 4". GATES TO BE
OWNER SHALL VERIFY ALL FIELD CONDITIONS SI DIMENSIONS AT JOB
-
N SELF-CLOSING & SELF -LATCHING WITH LATCH A MIN. OF 5' HIGH. ACCESS GATES
SITE. POOL LENGTH, GRADE BREAK LOCATIONS &DEPTH DIMENSIONS AS NOTED ON THE
----
PLOT PLAN SHALL COMPLY WITH IPSP SUGGESTED MINIMUM STANDARDS FOR THROUGH FENCING SHALL OPEN AWAY FROM THE POOL MAXIMUM VERTICAL CLEARANCE
8'0" 6%"
RESIDENTIAL POOLS OR APPLICABLE STATE AND LOCAL HEALTH DEPARTMENTS FROM GROUND TO POOL FENCING SHALL NOT EXCEED 2 INCHES. WHERE THIS VARIES FROM
-
REGULATIONS AND MANUFACTURERS RECOMMENDATIONS. LOCAL CODES, THE LOCAL CODES SHALL PREVAIL
- -
ELECTRICAL AND PLUMBING CITY OF FREMONT SPECIAL NOTES
83/Z"
1. ALL ELECTRICAL SHALL BE IN CONFORMANCE WITH THE 2013 CEC. THESE NOTES ARE ONLY APPLICABLE IN THE CITY OF FREMONT.
2. POOL SHELL AND PERIMETER PAVED AND UNPAVED SURFACES SHALL BE BONDED IN
- -
1• SEPARATE GRADING PERMIT IS REQUIRED FOR SWIMMING POOL INSTALLATION AT SLOPED
ACCORDANCE' WITH CEC 680.26(B). BONDING TO PERIMETER SURFACES SHALL BE SITE. GRADING PLAN SHALL BE PREPARED, STAMPED AND SIGNED BY A LICENSED CIVIL
PROVIDED AS SPECIFIED IN CEC 680.26(B)(2)(A) OR (2)(B) AND SHALL BE ATTACHED ENGINEER IN THE STATE OF CAUFORNIA.
8"--
TO THE POOL REINFORCING STEEL OR COPPER CONDUCTOR GRID AT A MINIMUM OF 2. MINIMUM DISTANCE BETWEEN EXTERIOR WALL OF ADJACENT BUILDING & SWIMMING POOL
FOUR (4) POINTS UNIFORMLY SPACED AROUND THE PERIMETER OF THE POOL SHALL BE S-0' WIDE WALKWAY PLUS THE WIDTH OF SWIMMING POOL BOND BEAM AND NO
3. OBTAIN ELECTRICAL AND PLUMBING PERMITS ALONG WITH POOL BUILDING PERMIT. LESS THAN THE DEPTH OF THE POOL ADJACENT TO THE BUILDING. REFER TO STANDARD
90, 8"
BALANCED AND SYMMETRICALLY PLUMBED THROUGH 'T'
FITTINGS. DRAINS SHALL BE SEPARATED BY THREE FEET IN
EXPANSIVE
..� WA DOES NOT REQUIRE $ i«.
{>
* IF POOL 'WALL HEIGHT DOES NOT EXCEED 5'-0" THEN NO ADDITIONAL
D INDICATES DISTANCE DOWN FROM TOP OF BUILDING FOOTING
WALL TO INCREASE SHOTCRETE COVER AND SURCHARGE
4. ALL EQUIPMENT SHALL BE LISTED AND INSTALLED PER MANUFACTURERS
RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL REGULATIONS.
POOL STRUCTURAL PLAN, DETAIL 2
3. FOR COMMERCIAL POOLS, HEALTH DEPARTMENT SUBMITTAL PLANS SHALL ACCOMPANY THIS
65 P.C.F.
ANY DIMENSION. SEE ELECTRICAL AND PLUMBING NOTE 8.
VERTICAL
STEEL
'E SURCHARGE DETAIL) R'*' '
;,•
BARS ARE REQUIRED. (DOES NOT APPLY TO SUPPLEMENT DETAILS)
ADD ADDITIONAL REINF. BARS.
5. POOLS SHALL BE EQUIPPED WITH A FILTERING SYSTEM & A DRAIN.
6. BACKWASH SHALL BE DISPOSED OF IN AN APPROVED MANNER.
STRUCTURAL PLAN INDICATING ALL REQUIREMENTS OF THE CBC AND COUNTY HEALTH
DEPARTMENT FOR PUBLIC SWIMMING POOLS.
#3 012"
3"
#3 O 12"
3"
#3 O 12-
1. FOR E.F.P. = 65 P.C.F., CONC. COVER = C + 2'
7• POOL/SPA WATER HEATER AND GAS PIPING INSTALLATION TO BE IN CONFORMANCE
WITH THE CPC.
8 CONTRACTORIS ADVISED TOINSTALLATION REERTSECTIONOFTHECALIFORNIA HEALTH &
CITY OF ROCKLIN SPECIAL NOTES
THESE NOTES ARE ONLY APPUCABLE IN THE CITY OF ROCKLIN.
3"
3�%'
.r
TYPICAL LONGITUDINAL SECTION N•T•s•
2
STANDARD WALL SECTION N•T•S•
1
#3 ® 6"
..... -
3'%*
#3 O 6"
-
- -
5%*
#3 O 6"
-
-
5'6" 3"
4"
SAFETY THE15928 POOL DRAIN
9. A REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER RP DEVICE IS REQUIRED ON
( )
1. IN THE ABSENCE OFA SITE SPECIFIC SOILS INVESTIGATION, TRU SWIMMING POOL AND SPA
CONSTRUCTION SHALL CONFORM TO STANDARD POOL STRUCTURAL PLAN STEEL
5"
7%'
6-6- 4"
SPECIAL DETAIL REQUIRED TOP OF
TOE OF SLOPE OR OTHER
NOTE:
- - - -
8%"
ALL SWIMMING POOL AND SPA FILLERS PER CPC 603.4.22
AND
GUNITE SCHEDULES FOR HIGH EXPANSIVE SOL WITH A MINIMUM SOIL EQUIVALENT FLUID
7'0" 5"
WHEN LESS THAN 10' SLOPE
SURCHARGE CONDITIONS
(SEE GENERAL NOTES #3)
WHEN ACTUAL SITE CONDITIONS EXCEED
THE UMITA11ONS BELOW OR ADDITIONAL
PROVIDE ADEQUATE DRAINAGE
BOND BEAM PER BEHIND POOL WALL
TABLE NO. 5 RAISED BOND BEAM
STRUCTURAL NOTES
1. SOIL SHALL HAVE A MINIMUM BEARING VALUE OF 1500 PSF CONCRETE SHALL BE
PRESSURE OF 65 P.C.F. (SCHEDULES C AND G
2. CONCRETE SHALL BE PLACED AGAINST UNDISTURBED SOIL OR CERTIFIED FILL COMPACTED
TO A MINIMUM OF 90% OF THE MAXIMUM DRY DENSITY IN ACCORDANCE WITH ASTM D1557
-
SURCHARGES NOT COVERED BY THIS
PLAN ARE PRESENT, ADDITIONAL TABLE #1 & DETAIL 112 ? 1/4' PER
SURCHARGE DETAILS ARE REQUIRED. FO
SPECIAL DETAIL REQUIRED
WHEN LESS THAN POOL DEPTH OR H/4 ao w (1) #4 0 TOP
_ (7.5' MAX. H/4) o o <-WATERPROOFING RECOMMENDED.
SPECIAL DETAIL REQUIRED '"I z
WHEN ESS THAN H/6 HORIZ. STEEL m 0 6" C.M.U. W/
BARS 91 12 O.C. iv #3 VERT. BAR ® 24" O.C.
(10' MIN., 20' MAX.) I N a m
SOLID GROUT.
ALTERNATIVE BOND�F' o 0
PER C.B.C. SECTION 1808.7.3 BEAM LOCATION l"^ ' ~ ^^"`""^"'" ' 3
\ / TWATER BOND BEAM
a ADDITIONAL SPECIAL DETAILS VEIL STm LINE. VERTICAL STEEL W/
0. SURCHARGE CONDITIONS - N.T.S. SEE TAKE 5, 24 MIN. EMBED.
REQUIRED FOR CONDITIONS ABOVE 3 SCHEDULES E, F OR G
3" ,C, TYP. HORIZ. STEEL
REFER TO AMERICAN NATIONAL STANDARD FOR RESIDENTIAL IN -GROUND SWIMMING POOLS PUBLISHED BY CLR • 'C' U 0 U 3"
AMERICAN NATIONAL STANDARD INSTITUTE (ANSI) AND THE NATIONAL SPA & POOL INSTITUTE (APSP) CLR.
C BEACH ENTRY STEEL AND SHOTCRETE SHALLOW SHELF (REEF)
a (GUNITE) THICKNESS PER MASONRY NOTES:
o APPROPRIATE WALL 1. CONCRETE BLOCK SHALL BE GRADE N (EXPOSED TO WEATHER), TYPE II (NON -MOISTURE
n!�.,w�wt*yMMLnlhM\.^JS.ML+f�Nq. "*aV`V.hnfthu
Q -;
CONTROLLED), NORMAL WEIGHT UNITS (135 PCF), CONFORMING TO CBC/IBC SEC. 2103, AND
¢ SCHEDULE. ASTM C 0 ALL CONCRETE BLOCK SHALL HAVE A DESIGN STRENGTH OF f 1500
z
¢ a POOL FLOOR THICKNESS 2. GROUTS ALL CONFORM TO CBC BC SEC. 2103 & ASTM C 476 WITH fc=2,000 PSI.. psi.
H /I
4 a a G SEE CBC/IBC TABLE 2103.12 FOR PROPORTIONS OF INGREDIENTS.
a MAY VARY TO ACHIEVE d �% Go 3. MORTAR SHALL BE TYPE M WITH fc = 1800 psi AND SHALL CONFORM TO CBC BC SEC.
�. DESIRED WATER DEPTH. -�------- 2103 & ASTM C 270. SEE CBC/IBC TABLES 2103.8(1),(2) FOR PROPORTION AND PROPERTY
�y SPECIFICATIONS.
NON -EXPANSIVE
E
EXPANSIVE
NO DECK/HIGH EXP.
F
G
E.F.P. 30 P.C.F.
45 P.C.F.
65 P.C.F.
D C
VERTICAL
STEEL
C
VERTICAL
STEEL
C
VERTICAL
STEEL
3'6" 3"
#3 012"
3"
#3 O 12"
3"
#3 O 12-
4'0' 3"
4 6, 3"
-
-
-
3"
3�%'
----
- -
4"
5%'-
---
� -
5'0" 3"
#3 ® 6"
..... -
3'%*
#3 O 6"
-
- -
5%*
#3 O 6"
-
-
5'6" 3"
4"
6%-
6'0" 3'M"
5"
7%'
6-6- 4"
-
6"
- - - -
8%"
- -
7'0" 5"
6"
#3 O 4"
8%*
#3 O 3-
7'6*5%'
-
-
6"
-
-
8%,
----
8'0" 6%"
--
--
-
7"
- -
- -
83/Z"
- -
- -
6'6" 7%'
8"--
90, 8"
--
-Ploil
9"
----
-
- -
1 O
-
--
9'6"
9 6" 9"
--
9"--
--
12'x"
11'0" 9"
-
13'
-
PLACED AGAINST UNDISTURBED SOIL OR BUILDING DEPARTMENT APPROVED 90%
COMPACT FILL. THIS PLAN IS NOT SUITABLE WHERE POTENTIAL EXISTS FOR
DIFFERENTIAL MOVEMENT FROM DISSIMILAR SOIL CONDITIONS UNDER POOL, SUCH AS
CUT -FILL TRANSITIONS.
2. ALL REINFORCING STEEL SHALL BE DEFORMED BARS & CONFORM TO ASTM A615 GRADE
40 FOR #3 BARS AND 14 BARS. SPUCES TO BE LAPPED A MINIMUM OF 24'. MINIMUM
CLEARANCE BETWEEN PARALLEL BARS IS 2 1/2'.
3. (1) 114 BAR IS EQUIVALENT TO AND MAY BE USED IN PLACE OF (2) #3 BARS, WITH
THE EXCEPTION THAT IF #4 BARS ARE USED FOR THE BASIC GRID, THE MAXIMUM
SPACING IS #4 BARS AT 18' O.C..
4. THE PLAN TABLES SPECIFY THE MINIMUM REQUIRED REINFORCEMENT. FOR CONVENIENCE
OF THE INSTALLER, THERE MAY BE MORE REINFORCEMENT THAN SPECIFIED AT ANY
GIVEN PONT IN THE POOL STRUCTURE.
5. BONDING/GROUNDING (PER THE CEC) OF THE STRUCTURAL REINFORCING MUST BE
INSTALLED PRIOR TO PLACEMENT OF CONCRETE.
6. SHOTCRETE (IGUNITE) TO BE IN CONFORMANCE WITH CBC SECTION 1910 & SHALL HAVE
A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS. WHERE APPLICABLE,
SHOTCRETE (GUNITE) TO BE IN CONFORMANCE WITH CBC SECTION 1904 DURABILITY
REQUIREMENTS.
7. CEMENT SHALL CONFORM TO CBC SECTION 1903.1, ACI 318 SECTION 3.2, ASTM C 150.
B. SHOTCRETE/GIUNITE IN CONTACT WITH SOIL SHALL BE IN ACCORDANCE WITH ACI 318
SECTION 4.3 IFOR CONCRETE EXPOSURE TO SULFATE AND AS DIRECTED BY LOCAL
BUILDING OFFICIAL
9. KEEP CONCRETE DAMP CONTINUOUSLY FOR 14 DAYS.
IO.ALL INTERIOR SURFACES OF POOL/SPA SHALL BE COATED WITH A WATER -TIGHT
SURFACE.
11. FLOOR TO W&LL TRANSITION RADIUS MAY VARY DEPENDING ON CONTRACTOR OR OWNER
DESIGN INTENT. RADIUS SHALL NOT BE LESS THAN 1 -FOOT AND SHALL NOT EXCEED
5 -FEET.
OWNER
1. KEEP SHOTCRETE (GUNITE) DAMP CONTINUOUSLY FOR 14 DAYS AFTER INSTALLATION.
2. DO NOT TURN ON LIGHT WHEN POOL IS EMPTY.
3. DO NOT USE BLACK RUBBER HOSE WHEN FILLING POOL (IT MARKS THE PLASTER).
CITY OF SAN JOSE SPECIAL NOTES
THESE NOTES ARE ONLY APPLICABLE IN THE CITY OF SAN JOSE.
1. ENGINEER TO SPECIFY TABLES AND DETAILS THAT APPLY TO A SPECIFIC JOB BY ONE OF
THE FOLLOWING METHODS:
A A SITE PLAN STAMPED AND SIGNED BY THE ENGINEER REFERRING TO THE
APPROPRIATE DETAILS AND SCHEDULES.
B. A LETTER STAMPED AND SIGNED PROVIDED THE SAME INFORMATION.
C. A STANDARD POOL PLAN WITH THE ADDRESS WRITTEN IN BY THE ENGINEER ALSO
IDENTIFYING SCHEDULES AND DETAILS.
2. SWIMMING POOL AND SPA CONSTRUCTION SHALL CONFORM TO STANDARD POOL
STRUCTURAL PLAN STEEL AND GUNITE SCHEDULES WITH A MINIMUM SOIL EQUIVALENT
FLUID PRESSURE OF 45 P.C.F. FOR EXPANSIVE SOL (UNITED SOIL CLASSIFICATIONS GW,
GP, GM, GC, SW, SP, SM, SM -SC, ML). AN EQUIVALENT FLUID PRESSURE OF 30 PCF,
NON -EXPANSIVE SOIL, MAY ONLY BE USED IF RECOMMENDED BY A SOILS ENGINEER.
3. OVER THE COUNTER PERMITS ARE NOT POSSIBLE IN AREAS DESIGNATED AS 'SPECIAL
GEOLOGICAL HAZARD.' THE MASTER PLAN MIGHT BE USEABLE BASED ON THE FINDINGS OF
THE GEOLOGIC AND GEOTECHNICAL REPORTS.
4. IN ACCORDANCE WITH CBC SECTION 1802.2.7, A SITE SPECIFIC SOLS INVESTIGATION MAY
BE REQUIRED FOR PROJECTS LOCATED IN SEISMIC DESIGN CATEGORIES D, E, OR F.
PERMIT#Ae
BUTTE COUNTYDEVELOPMENTSERVICES,
REVIEWED FOR
DATE ODE COMPLIANCE
SEE STRUCTURAL NOTE #1 '
SHALLOW FEATURES - MAINTAIN 18- UNDISTURBED MIN. 9EM BEDMENT COMPACTED SOIL INTO N.T.S. 4 RAISED BOND BEAM N.T.S.LUNOTES BY THE USE OF THIS PLAN, THE USER ACKNOWLEDGES THAT HE
HAS READ & UNDERSTANDS ALL OF THE NOTES INCLUDED HEREIN. 6
NOTE: BOND BEAM PER TABLE 9' & LARGER BRICK OR PRECAST PROPERTY RIGHTS TO ALL DRAWINGS, REPRESENTATIONS,
SPA AIR -LINE 6"-8°
N0. 1 &DETAIL #12. -�`-�`- 2" 2' CONCRETE COPING. 91/2- 3RD AND/OR 4TH IDEAS, DETAILS, NOTES & SPECIFICATIONS EITHER COPIES
MAY BE LOOPED 1 / OR ORIGINALS THEREOF THAT MAY BE INCORPORATED INTO
INTO SPA BOND cv a ,n, __ _ EXPANSION JOINT &SEALANT to 12" BAR LOCATION THIS DESIGN ARE THE PROPERTY SOLEY OF POOL
? " I ' i-' O # F LEVEL TOP OF GUNITE 4'-0" MIN. REQ'D. FOR EXPANSIVE SOILS. I MAY VARY TO ENGINEERING, INC. PERMISSION FOR ANY COPIES OF SAID
BEAM, MAINTAIN X o - I'. I 2 3 ,� , , (4) #3 BARS COPYRIGHTED MATERIALS, DRAWINGS, REPRESENTATIONS,
¢ z ¢ �_ , W GROUT & PLACE PER DETAIL 8 y PROVIDE 2 1/2"
1" CLR. TO REINF. ¢ I r}- 6' BARS. - / DECKING # r� IDEAS, DETAILS, AND SPECIFICATIONS EITHER ORIGINAL OR
ICD N O - #15 FELT OR 4 MIL F- ELECTRICAL 'J' BOX. CLI. BETWEEN COPIES THEREOF TO BE MADE, COPIED OR ALTERED BY
w I THICK X #3 BARS is 1" MIN. CLI. VISQUEEN ON TOP. PARALLEL BARS. ANY PERSON, BUSINESS, OR CORPORATION MAY ONLY BE
�' 3" ¢ I AROUND ALL COPING 8" MIN. ABOVE DECK, WATER / O # �� a - H
EA. WAY. PIPES. " #3 BARS WAY. <-LINE
FLOOD LINE WHICH GRADE. PER TABLE 1 & DETAIL ARS DECKING. AUTHORIZED WITH THE EXPRESSED WRITTEN PERMISSION
�. SPA LIGHT 12" O.C. �, FINISH BOND BEAM W 4 3 B
OF POOL ENGINEERING, INC. BY THE USE OF THIS PLAN,
_ �w # #12. m : TIE THE USER ACKNOWLEDGES THAT HE HAS READ &
- SKIMMER BOND BEAM PER TABLE NO. 1. UNDERSTANDS ALL OF THE NOTES INCLUDED HEREIN.
EQ. EQ. �C yyA�R WATER _ �..,. PLUMBING MAY BE LOCATED
LINE. 24" .:I " COVER. VA : �� �- co ,m,rw w, •w vrti IN BOND BEAM LOWER CORNER BOND BEAM HORIZONTAL
REINFORCING PER DETAIL 10. 6" LINE. \ "
NOT REQUIRED IF 6" MIN. # MIN. LAP (2) #3 BARS V\\ ' _ - 2 1 2' a MAINTAIN 1' CLR. TO REINF. 3" BARS MAY BE OVER OR CALCS BY: A.J.C.
I = 1 '� /
�\ z COMPACTED M UNDER VERTICAL BARS.
CLEAR PROVIDED. - BEND �\ ' CLI. ¢ o
\\ FILL X � DRAWN BY' T.L.L.
z 5' MIN.- �� BOND �� sy Z o ��`' PRECAST COPING OR BRICK
24" MIN. LAP t - w 9 z
a AROUND ALL - BEAM \!�
CIRCULATION DRAINS: `O INTO SPA FLOOR #3 BARS LI ¢ O a o ® J
PROVIDE 2 ANTI -VORTEX SUCTION OUTLETS PER PUMP, OR POOL WALL. O 12'O.C. T!=`1 J UNDER ��\\ - X \��� 1 `i' a 8" CHECKED BY: R.L.L.
O I t (2) #3 'Z' BARS SKIMMER. #8 COPPER ¢ \'1O \t�• v o Q
COVERED WITH APPROVED A.S.M.E. STANDARD A112.19.8 EA. WAY. ��.�_ -I \�Py 6 a m X (2) #3 BARS FOR USE ONLY AT:
ANTI -ENTRAPMENT GRATES, THAT ARE HYDRAULICALLY GROUND WIRE r \ o �A = , ¢ -I
I I \ N ' Krawec Residence
BALANCED AND SYMMETRICALLY PLUMBED THROUGH "T" DAM WALL 6' DAM - LAP INTO SPA REINF. SECTION AT SKIMMER �` LJ w E -VENEER.
FITTINGS. DRAINS SHALL BE SEPARATED BY THREE FEET IN HORIZ. BAR C.E.C. APPROVED OF _ \\ _ - I o BEND 4127 Tiberon Way
12' DAM - LAP INSIDE BARS INTO SPA REINF. <s FIXTURE Fo - - _ 1,o VERT. STEEL
Chico, CA 95973
ANY DIMENSION. SEE ELECTRICAL AND PLUMBING NOTE 8. LAP SPLICE: CONDUIT.
- LAP OUTSIDE BARS INTO POOL REINF. LENS Ey - - - - 45. OR 90'. �\
zl 24" 6" RECESSED - O,P o� I_ E -TILE C
SPA DETAILS MAY BE USED POOL MIN. (2) #3 BARS MI . LIGHT. M.l : , q�A J`' ? BOND BEAM PER -� / l
SPA DETAILS - N.T.S. 7 LAP EACH WAY S TABLE NO. (--PLASTER A. q�
FOR SPAS WITHOUT POOLS. AROUND NICHE. 3, 18" MIN �o��P � co
LAP, TYP. ROCK OR BRICK NOTCH z
4'-0" MIN. IMPERVIOUS DECK 11 •' �R 1 `�'I LL' R rn
M
APPROVED SEALANT - VERT. STEEL - , WOOD POST FROM r'. 3!31/201
SLOPE 1/8"-1/4" INSTALL PER MANUFACTURER (]
3 1/2---j PER FOOT DRAIN O #3 0 6" O.C. ATTACHED PATIO COVER
/ �- (2) #3 BARS. NOTES 5'-0' DEEP &BELOW. MAX. DEAD +LIVE LOAD = 2000 Ib. CIVIL �Q
M a 1 1. INSTALL NO. 8 COPPER GROUND WIRE FROM LIGHT NICHE TO •`te r OR 9� OQ�
w x - ! NOTE: ? HORIZONTAL STEEL. Cb v I I LEVEL TOP OF BOND BEAM OF CN-*
w J ZILt I _L 5" MIN. BRASS CONDUIT TO POOL REBAR, OR NON-METALUC ROCK ON BOND BEAM. I I WITH GROUT &PLACE 15
C" � o SATURATION PROVIDE CONTROL JOINTS 3' CLR. -�"r7 #3 BARS 0 12" O.C. TYP. i�n
N I RECOMMENDED WHERE APPROPRIATE. = ` CONDUIT CAN BE USED WITH INSULATED N0. 8 COPPER WIRE I
TYPICAL TYPICAL GALV. SIMPSON POST BASE I FELT OR 4 MIL VISQUEEN ON
it I PRIOR TO INTERIOR W/ APPROVED POTTING COMPOUND PER THE C.E C NOTE BOND PER ELECTRICAL & TOP OF BOND BEAM. PLAN VALID ONLY WITH WET
POURING DECK. I . ' 2 SWIMMING POOL LIGHTING FIXTURES SHALL COMPLY WITH EXTRA REINFORCING TO EXTEND PLUMBING NOTE 2. STAMP dt ENGINEER'S SIGNATURE
PLAN AT SKIMMER APPLICABLE UNDERWRITERS' LABORATORIES REQUIREMENTS " IN RED INK ON PLAN.
SEE ELECTRICAL AND REMAINDER OF JOINT IN STYROFOAM OR 24 MIN. EACH SIDE OF RAMP. MASTIC
FOR LIGHTING FIXTURES U.L STANDARD 676.
€ PLUMBING NOTE #2 REGARDING FOOLING RECOMMENDED OTHER EXP. MATERIAL CONCRETE SHALL 3 1/2" MIN. CONC. DECKING. • AUTHORIZED SIGNATURES:
EQUIPOTENIIAL BONDING GRID FOR EXPANSIVE SOILS. NOT TOUCH COPING, BOND BEAM OR-��---[Tt= TIE
ADJACENT STRUCTURES.. CANTILEVER CONCRETE RONALD L. TO D L. ACHER, P.E.
EXPANSIVE SOIL DETAILS I
IN EXPANSIVE USE T B E 1,WERE MSCHIN DEDULE C'ECK M� N.T.S. 8 SKIMMER DETAIL N.T.S. g SECTION AT LIGHT N.T.s. 10 SHALLOW/DEEP END RAMP 11 BOND BEAM DETAILS N•T•s• 12 JEFFERY COLLINS, KRISTOF P.E.
CHRIS BIEDENBACH, P.E.
STANDARD PLAN APPROVALS: STANDARD pOOI Ron Lacher, R.C.E. SHEET.