Loading...
HomeMy WebLinkAboutB16-1567 040-170-127Substantial Improvement Worksheet for Projects within FEMA Floodplain APN: 1-7L)— l 7i% Date: J.JI �-` ?moi , 2c� U0 EXISTING BUILDING: USE AREA SF -VALUE X X = X X = X X' _ X X = X X = X X = Existing Structure Value (ESV): 10 ci, -7q7 /601000 -- PROPOSED ADDITION -REMODEL: USE AREA SF -VALUE TOTAL fZ �ajX_ f a Xaa X X = X X = X X _ X X = X X = X X = REMODEL CONTRACT: Improvement Value (IV):0 Improvement Percentage = IV ESV lam. `E.\� �4'[?[�51T(; Ii;iil�lin�,[3uildin`� Ford}> �k Do�+!ents•?O1�`t'�ord Docs �+itl; �inc�ated I�� :w '!1 l 2''T [v:}d Pain C>cclar ztio Form DPC-, Re ised - - - Page 2 of 2 *U" Butte County Department of Development Services PLAN CHECK 7 County Center Drive, Oroville, CA 95965 Main Phone (530) 538-7601 Fax (530) 538-7785 FLOOD PLAIN DECLARATION I declare the market value of the pr'opposeedcoo/nstruction work under building permit application number: Y' • 1% / at the location of q5?�Mmmi S W. Assessor's Parcel Number: 0 q 0 • 1-70 - 1 /i / for the construction of an addition and/o didel nsisting of Xifaw ' will not equal or exceed the definition of "Substantial Improvement" as defined below. I am aware the building site is located within special flood hazard area zone Ac— Community Number, Map Panel, and Suffix ora 01 CC 05 Ulr&ted I - (0. 11, and may be at risk of flooding although I am not required to comply with flood plain management criteria. Property Owner: ye)4L &eo Phone Number: 5-5D —'F)9 — 7701 Print Name: sj FORM NO DPC-04 BUTTE COUNTY AUG 0 8 2016 DEVELOPMENT SERVICES *Substantial Impj�trvement is defined as follows: any reconstruction, rehabilitation, addition, or other proposed new development of a structure, the cost of which equals or exceeds fifty (50) percent of the market value of the structure before the "start of construction" of the improvement. The Substantial Improvement cost is cumulative and includes all improvements that are not listed below as being excepted and that have occurred within the proceeding five years. This term includes structures which have incurred "substantial damage", regardless of the actual repair work performed. The term does not, however, include either: a. Any project for improvement of a structure to correct existing violations or state or local health, sanitary, or safety code specifications which have been identified by the local code enforcement official and which are the minimum necessary to assure safe living conditions; or b. Any alteration of a "historic structure" provided that the alteration will not preclude the structure's continued designation as a "historic structure." Note: If the improvement percentage, cumulative over the last 5 years, equals or exceeds 40% of the market value of the structure before the "start of construction" of the improvement, a certified appraisal shall be required to verify the proposed work will not constitute a substantial improvement. Substantially improved structures shall meet the minimum building standards of the National Flood Insurance Program & Butte County's Flood Plain Ordinance (BW,-21)_�DEVE��T r � ; TE COUNSERVICES REVIEWED l= BUILDING ENERGY ANALYSIS REPORT North Star 111 Mission Ranch Blvd Ste 100 Chico, CA 95926 5308931600 Report Prepared by: Rick Rocklewitz NRG Compliance, LLC PO Box 3777 Santa Rosa, California 95402 707-237-6957 . C .-� COMPLIANCE, LLC Job Number: /�� /567 PERMIT #_ 071916 BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR CODE COMPLIANCE Date: DATE_ 8/4/2016 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC —www.energysoft.com. EnergyPro 6.7 by EnergySoft User Number. • 5581 w: ut I bolo PROJECT: BUT'T'E COUNTY Keith George 0 $ 2016 9533 Cummings Lane AUG Durham, CA 95938 pEVELOPMENT SERVICES 9)(,-1S67 Project Designer: North Star 111 Mission Ranch Blvd Ste 100 Chico, CA 95926 5308931600 Report Prepared by: Rick Rocklewitz NRG Compliance, LLC PO Box 3777 Santa Rosa, California 95402 707-237-6957 . C .-� COMPLIANCE, LLC Job Number: /�� /567 PERMIT #_ 071916 BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR CODE COMPLIANCE Date: DATE_ 8/4/2016 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC —www.energysoft.com. EnergyPro 6.7 by EnergySoft User Number. • 5581 w: ut I bolo TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R -PRF -01 -E Certificate of Compliance Form RMS -1 Residential Measures Summary Form MF -1 R Mandatory Measures Summary J 1 2 3 9 10 EnergyPro 6.7 by EnergySoft Job Number. ID: 071916 User Number. 5581 1 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Building Calculation Date/Time: 14:53, Thu, Aug 04, 2016 Calculation Description: Title 24 Analysis Input File Name: george, keith remodel, REV B.xml CF1 R -PRF -01 Page 1 of 6 GENERAL INFORMATION 01 Project Name Residential Building J, 02 Calculation Description Title 24 Analysis 06 07 03 Project Location 9533 Cummings Lane t.' f—, Energy Use (kTDV/ft2-yr) Standard Design 04 City Durham 05 Standards Version Compliance 2015 06 Zip Code 95938 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ11 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 90 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 1478 15 Number of Zones 1 16 Slab Area (ft2) 0 17 Number of Stories 1 18 Addition Cond. Floor Area 0 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) 0 21 Glazing Percentage (%) 9.8% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building DOES NOT require HERS Verification 11' cv� rrr�.'aa Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-08-0414:54:31 ENERGY USE SUMMARY J, 04 05 06 07 08 t.' f—, Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 66.78 65.53 1.25 1.9% 0 (jr, Space Cooling 121.21 120.17 1.04 0.9% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 16.53 14.33 2.20 13.3% Photovoltaic Offset ---- 0.00 0.00 --- Compliance Energy Total 204.52 200.03 4.49 2.2% Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-08-0414:54:31 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Building Calculation Date/Time: 14:53, Thu, Aug 04, 2016 Calculation Description: Title 24 Analysis Input File Name: george, keith remodel, REV B.xml REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. NO SPECIAL FEATURES REQUIRED CFI R -PRF -01 Page 2of6 HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • — None — Cooling System Verifications: • — None — HVAC Distribution System Verifications: • -- None -- Domestic Hot Water System Verifications: • ..None — ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)* 260.83 256.34 4.49 1.7% * includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 r-- t_- a $`Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Residential Building 1478 1 3 1 0 1 ZONE INFORMATION ;'�01 02 03 04 05 06 07 Zone Floor Area Avg. Ceiling tom,; fi =Zone Name Zone Type HVAC System Name (ftZ) Height Water Heating System 1 Water Heating System 2 '-Tirst Floor Conditioned HVAC Systeml 1478 9 DHW Sys 1 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-08-04 14:54:31 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01 Project Name: Residential Building Calculation Date/Time: 14:53, Thu, Aug 04, 2016 Page 3 of 6 Calculation Description: Title 24 Analysis Input File Name: george, keith remodel, REV B.xml OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft) Window & Door Area (ft) Tilt (deg) Status Verified Existing Condition East Wall First Floor Default Wall Prior to 197 90 Front 465.8 99.5 90 Existing No South Wall First Floor Default Wall Prior to 197 180 Left 269.2 8.5 90 Existing No West Wall First Floor Default Wall Prior to 197 270 Back 465.8 53.5 90 Existing No North Wall First Floor Default Wail Prior to 197 0 Right 269.2 43 90 Existing No Roof First Floor Default Roof Prior to 197 Insect Screen (default) New 1478 1 North Wall (Right -0) Existing No Raised Floor First Floor Default Floor Crawlspace I 11478 Existing 1 1 1 Existing No ATTIC 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) Height (ft) Multiplie r Radiant U -factor Statu Verified Existing Name Construction Type Roof Rise Roof Reflectance Roof Emittance Barrier Cool Roof s Condition Attic First Floor Attic RoofFirst Floor Ventilated 4 0.1 0.85 No No Existi No 0.65 Insect Screen (default) Existing No (; Nhdow 3 West Wall (Back -270) ---- ---- ng 26.0 WINDOWS 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) Height (ft) Multiplie r Area (ft2) U -factor SHGC Exterior Shading Status Verified Existing Condition Window East Wall (Front -90) ---- ---- 1 79.5 0.58 0.65 Insect Screen (default) Existing No rTWindow 2 South Wall (Left -180) ---- ---- 1 8.5 0.58 0.65 Insect Screen (default) Existing No (; Nhdow 3 West Wall (Back -270) ---- ---- 1 26.0 0.58 0.65 Insect Screen (default) Existing No v. endow (New) West Wall (Back -270) ---- 1 7.5 0.34 0.34 Insect Screen (default) New N/A "' ` --Window 4 North Wall (Right -0) ---- ---- 1 23.0 0.58 0.65 Insect Screen (default) Existing No Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-08-0414:54:31 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Building Calculation Date/Time: 14:53, Thu, Aug 04, 2016 Calculation Description: Title 24 Analysis Input File Name: george, keith remodel, REV B.xml CFI R -PRF -01 Page 4 of 6 DOORS 01 02 03 04 05 01 02 03 04 05 06 Name Side of Building Area (ft) U -factor Status Verified Existing Condition Door East Wall 20.0 0.50 Existing No Door (New) West Wall 20.0 0.50 New No Door 2 North Wall 20.0 1 0.50 Existing No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 07 08 Heater Element Type Tank Type Total Cavity Winter Design Input Rating Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers Number of Fraction 0 Verified Existing Name System Type • Cavity/ Frame: no insul. / 2x4 Top Chrd Water Heater Heaters (%) 2x4 Top Chord of Roof Truss @ 24 Condition r 17DF)W Sys 1 Roof Deck: Wood Siding/sheathing/decking Attic RoofFirst Floor Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Floor Surface: Carpeted Floors Over Floor Deck: Wood Siding/sheathing/decking Default Floor Crawlspace Crawlspace Wood Framed Floor 2x12 @ 16 in. O.C. none 0.216 Cavity/Frame: no insul. / 2x12 • Inside Finish: Gypsum Board • Cavity/ Frame: no insul. / 2x4 • Exterior Finish: Wood Default Wall Prior to 197 Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.302 Siding/sheathing/decking • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 Default Roof Prior to 197 attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R11 0.083 Over Floor Joists: R-1.9 insul. WATER HEATERS WATER'HEATING SYSTEMS r.. • 101 02 03 04 05 06 07 08 Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Solar Standby Loss (Fraction) DHW Heater 1 's -- Small Storage 50 0.67 EF Number of Fraction 0 Verified Existing Name System Type Distribution Type Water Heater Heaters (%) Status Condition r 17DF)W Sys 1 DHW Standard DHW Heater 1 1 Annual New No WATER HEATERS •01 02 03 04 05 06 07 08 _ Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.67 EF 40000-Btu/hr 0 0 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-08-0414:54:31 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Building Calculation Date/Time: 14:53, Thu, Aug 04, 2016 Calculation Description: Title 24 Analysis Input File Name: george, keith remodel, REV B.xml CF1 R -PRF -01 Page 5 of 6 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1 n/a n/a n/a n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Zonally Controlled Multi -speed Compressor Heating System Cooling System NoCooling - No cooling equipment N/A N/A No No N/A Distribution Fan Floor Area Verified Existing Name System Type Name Ducted Name Ducted System System Served Status Condition HVAC System Other Heating and Heating No Cooling No - none - HVAC Fan 1 1478 Existing No Cooling System Component 1 Component 1 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 Wall FurnaceGravity - Ductless gravity flowed wall furnace 63 AFUE HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 Name System Type Efficiency EER SEER Zonally Controlled Multi -speed Compressor HERS Verification r.Cooling Component 1 NoCooling - No cooling equipment N/A N/A No No N/A IAQ (Indoor Air Quality) FANS r.-" 01 02 03 04 05 r -J I"; Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification �—SFam IAQVentRpt 0 Default 0 Not Required Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFSR-04072016-744 Report Generated at: 2016-08-04 14:54:31 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Building Calculation Date/Time: 14:53, Thu, Aug 04, 2016 Calculation Description: Title 24 Analysis Input File Name: george, keith remodel, REV B.xml CFI R -PRF -01 Page 6 of 6 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Rick Rocklewitz Ric nckiewltx PE -D9-1867 Company: Signature Date: NRG Compliance, LLC 8/4/2016 Address: PO Box 3777 CEA/HERS Certification Identification (If applicable): City/State ip: S anta Rosa, California 95402 Phone: 707-237-6957 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Larry Coffman `1XIL Company: Date Signed: North Star & ((� �' c�J �Uo� 0 < <o Address: 111 Mission Ranch Blvd Ste 100 License: C — 0 �� City/State/Zip: Phone: Gfiico, CA 95926 5308931600 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-08-0414:54:31 RESIDENTIAL MEASURES SUMMARY Krn5-'I Project Name Keith George Project Address 9533 Cummings Lane Durham Building Type m Single Family ❑ Addition Alone 1:1Multi Family m Existing+ Addition/Alteration California Energy Climate Zone Total Cond. Floor Area Addition CA Climate Zone 11 1,478 0 Date 8/4/2016 # of Units 1 INSULATION Construction Type Cavity Area (ft) Special Features Status Floor Wood Framed w/Crawl Space - no insulation 1,478 Existing Wall Wood Framed - no insulation 1,266 Existing Door Opaque Door - no insulation 40 Existing Door Opaque Door - no insulation 20 New Roof Wood Framed Attic R11 1,478 Existing FENESTRATION Total Area: 145 Glazing Percentage: 9.8 % New/Altered Average U -Factor: Orientation Area f 2 U -Fac SHGC Overhang Sidefins Exterior Shades 0.34 Status Front (E) 79.5 0.580 0.65 none none Bug Screen Existing Left (S) 8.5 0.580 0.65 none none Bug Screen Existing Rear 26.0 0.580 0.65 none none Bug Screen Existing Rear (IM 7.5 0.340 0.34 none none Bug Screen New Right (N) 23.0 0.580 0.65 none none Bug Screen Existing HVAC SYSTEMS Qty. HeatingMin. Eff CoolingMin. Eff Thermostat Status 1 Gravity Wall Furnace 63% AFUE No Cooling 13.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Cooling Duct Duct Location R -Value Status HVAC System Ductless/ No Fan Ducted Attic 6.0 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 1 Small Storage Gas 50 0.67 Standard New ..+•+ v � rsan w�: 2n19-nR-nar1I.-55:12 •+ > -ID: 071916 "' k t, Page 9 of 13 o""rev v.. .. ",�, .,..,. .._...__.. 2013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the Building Envelope Measures: § 110.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain § 110.6(a)5: Coefficient SHGC , and infiltration that meets the requirements of § 10-111 (a). § 110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed. § 110.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the § 110.8(i): installation of a cool roof is specified on the CFIR. § 110.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFIR. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a §150.0(a): rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. §150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -value. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U - § 150.0(c): factor). §150.0(d): Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor. In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior § 150.0(g)l: walls, vented attics and unvented attics with air -permeable insulation. In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class II §150.0(g)2: vapor retarder. In a building having a controlled ventilation crawl space, a Class I or Class II vapor retarder shall be placed over the earth floor of §150.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; §150.0(1): have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor meets the requirements of § 110.8 Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U- 150.0 § (q)' factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: §150.0(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is §150.0(e)1B: equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device. § 150.0(e)iC: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside §150.0(e)2: of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation § 110.3(c)5: valve, and recirculation loop connection requirements of § 110.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- § 110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool ands a heaters. Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified § 150.0(h)1: in § 150.0(h)2. Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any § 150.0(h)3A: dryer vent. §150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c). Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped §150.00)lA: with insulation having an installed thermal resistance of R-12 or greater. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external §150.0(j)1B: insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. For domestic hot water system piping, whether buried or unburied: the first � feet of hot and cold water pipes from the storage tank, all piping with a nominal diameter of 3/4 inch or larger, all piping Adciated with a domestic hot water recirculation system §150.00)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and all hot water pipes from the heating source to kitchen fixtures must bHnsu4atea-8ccoiding to i$e'requiremenis of TABLE 120.3- All domestic hot water pipes that are buried below grade must be installed ,jn a water.prpof and non -crushable casing or sleeve §150.06)2B: that allows for installation, removal, and replacement of the enclosed pipe and insulation. 7n12 T n.x,_u>CA Rneirinntial Manrlatnlry M-nrui p..0 .l)Ofil mare Pipe for cooling system lines shall be insulated as specified in § 150.00)2A. Piping insulation for steam and hydronic heating §150.00)2C: systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A. § 150.06)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For § 150.06)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I §150.06)3B: or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class II vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the §150.0(n)l: space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. §150.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5. Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC) § 150.0(n)3: or by a testing agency approved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed §150.0(m)l: with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than'/. inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints §150.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other §150.0(m)3-6: requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic § 150.0(m)7: dampers. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers §150.0(m)8: except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, § 150.0(m)9: sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. §150.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be §150.0(m)11: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal §150.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of §150.0(m)12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The §150.0(m)13: space conditioning system must also demonstrate airflow > 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy <_ 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode, an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of>_ 350 CFM per ton of nominal cooling §150.0(m)15: capacity, and operating at an air -handling unit fan efficacy of:5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of §150.0(o): central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the Whole Building Ventilation. Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with �� §150.0(o)IA: Reference Residential Appendix RA3. • - r> Pool and Spa Heating Systems and Equipment Measures: '"' " m M: , .i e " a ` ` a ! 1 "? Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency § 110.4(a): Regulations; an on-off switch mounted outside of the heater that allows' shutting off the heater N %ithout adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating. ')nl I I.nw_Ri-w RPcidpntial Mandatary Measures Summary Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction § 110.4(b)1: and return lines, or built-up connections for future solar heating. § 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro- § I I0.4(b)3: grammed to run only during off-peak electric demand periods. § 110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. §150.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: § 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9. Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with § 150.0(k) in accordance with TABLE § 150.0(k)IA: 150.0-A or TABLE 150.0-B, as applicable. When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply §150.0(k)IB: with the applicable provisions of § 150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with § 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has §150.0(k)IC: been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting er electrical box. §150.0(k)ID: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no §150.0(k)IE: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §130.0(c). Night lights do not need to be controlled by vacancy sensors. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable §150.0(k)1F: requirements of § 150.0(k). § 150.0(k)2A: High efficacy luminaires must be switched separately from low efficacy luminaires. § 150.0(k)2B: Exhaust fans shall be switched separately from lighting systems. § 150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. § 150.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § I50.0(k). § 150.0(k)2F: Lighting controls comply with applicable requirements of § 110.9. An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if it functions as a dimmer § 150.0(k)2G: according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in §150.0(k)2. An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if. it § I50.0(k)2H: functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0(k)2. A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the § I50.0(k)2I: functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2. § 150.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only § 150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting. Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated § 150.0(k)4: cabinet. A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom §150.0(k)5: shall be high efficacy or controlled by vacancy sensors. Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and § 150.0(k)6: controlled by vacancy sensors. Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high §150.0(k)7: efficacy, or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing § 150.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § 150.0(k), the ballasts shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9. For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and § 150.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses ih6 motion'genging function and automatically reactivates the motion sensor within 6 hours; and b"J l L a t m ; ,1 ', '�• , iii. Controlled by one of the following methods: 2013 Low -Rise Residential Mandato a. Photocontrol not having an override or bypass switch that disables the photocontro►; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically tum the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the following requirements: i. Shall comply with § 150.0(k)9A; or ii. Shall comply with the applicable requirements in § 110 .9, § 130 .0, § 130.21 § 130.4 § 140.7 and § 141.0. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by §150 0(k)9B or 150 0(k)9D shall comply with the applicable requirements in §110.9, §130.0, § 130.2 $130.4 §140.7 and §141.0. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in § 110.9, §130.0, § 130.2, § 130.4, § 140.7 and § 141.0. Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined according to § 130.0(c). Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in § 110.9, § 130.0, §130.1, § 130.4, §140.6, and § 141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: i. Comply with the applicable requirements in §110.9, §130.0, §130.1, §140.6 and §141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. Measures Summa § 150.0(k)9B: § 150.0(k)9C: § 150.0(k)9D: §150.0(k)10: §150.0(k)11: § 150.0(k)12A: § 150.0(k)12B Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a § 110.10(a)1: tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with the re uirements of 110.10 throu h 110.10(e). § 110.10(a)2: Low-rise multi -family buildings shall comply with the requirements of § 110.10(b) through § 110.10(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for § 110.10(b)1: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building ro'ect and have a total area no less than 15 percent of the total roof area of the buildin excludin an skylight area. § 110.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. eys, architectural features, and roof mounted equipment, shall be § 110.10(b)3A: No obstructions, including but not limited to, vents, chimn located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice §1 10.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane. § 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of § 110.10(c): interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10 c shall be provided to the occupant. § 110.10(e)1: The main electrical service panel shall have a minimum busbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a § 110.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location, and permanently marked as "For Future Solar Electric". W �`m'0O moo° 3 CLz CU ro m m o c ro Y EL°'°`Q=0'cnm�ayi 'O C E CLy 0a) O y H U ZL C LO E r- 0 p U r Z "� 00 '� C .y .` O O 0 CU 0 0 a) 0a), a7° 0 a) C y y M ro d C to j Cm W D) an d a U U O o O a0 E 015tL- E° rn ms°. �L' E �v cY o gas rna) ti a>� T`0 rn C A O �c'c`a0�^vi aiccm 0 °- U YO O 0 X' c m 'p d Z$Ec9.6a)LuEG M G O r r O N ) C r T M Y O z a o. W O � opo 0 s -i Cf)M N O (Ll O Z O L) W ��tl.- a) 'o x o a �" �D �- W Ux O CO Lr) Q 0) o e Sheet Title TITLE SHEET Status: SUBMITTAL SET Drawn By: TLH Checked By: Date: 07/12/2016 Job No. 16-164 6-16`t Sheet No. A0 0 0 Plotted: Fri, Aug 05 '}' c6 U U y A G, NQi W 4 a o. W O � opo 0 s -i Cf)M N O (Ll O Z O L) W ��tl.- a) 'o x o a �" �D �- W Ux O CO Lr) Q 0) o e Sheet Title TITLE SHEET Status: SUBMITTAL SET Drawn By: TLH Checked By: Date: 07/12/2016 Job No. 16-164 6-16`t Sheet No. A0 0 0 Plotted: Fri, Aug 05 '}' m �v o > `o m mIz ca W f°— c E CL f3tl IC O� = y N y O r m 0 m N E e cc co��c�Y E y� CL o �st� E EDO U L C U O` C y m m m 3 Z m C O m C ZO�a�M��ami GOLL-O m Ca ,m° N v 3 c m y W m N ' U U) m o �v' ECn M.O d O o H E Z a, aXi m� a��i idz 0)m o tm c o L L O •00 N _C C N m r Tam a0)Ch O Om U O m X C Cv Z v5 c mw E cY m c r M N O � E N RO C r M O g z 0 0 0 C7 a� a� M N �p to r' O N N .. 0 C-4 A �a U b O Q ARc�r Bene al Dace 0-0,, 1.3047 n 1 'LARRY y EDWIN OFFMAN 9LIFOR��' Sheet Title OVERALL SITE PLAN Status: SUBMITTAL SET Drawn By: TLH Checked By: Date: 07/12/2016 Job No. 16-164 Sheet No. A100 Plotted: Fri, Aug 05 2016 00 x U U A a � 4 0 0 0 C7 a� a� M N �p to r' O N N .. 0 C-4 A �a U b O Q ARc�r Bene al Dace 0-0,, 1.3047 n 1 'LARRY y EDWIN OFFMAN 9LIFOR��' Sheet Title OVERALL SITE PLAN Status: SUBMITTAL SET Drawn By: TLH Checked By: Date: 07/12/2016 Job No. 16-164 Sheet No. A100 Plotted: Fri, Aug 05 2016 c �:9 CO wa) OE co O N.F" O L L Cn a) Q I O U C UV- O` C � 00 C N p 0 0 mC N cnp C N dO.CLp O . U 3 0 a� N W y N cc C C T UCc C, U fn CU W r C 7 E N 0 r• d O d O E O H E Z tm 0 �0 QL E E �� �io o41 y L D1 0 O U) C N y a) a) V O L �, = O C m c C` N O pp'U p O m n'c'ro'0 a) Z a)WES� M C Q M on V J C c c 0 M Y O I� z 0 0 W O �� O W a�� s- Cf)M N W �U� 'o x o p �D �r a w UxC CO a Lr) 0 0 Sheet Title DEMO PLAN Status: SUBMITTAL SET Drawn By: TLH Checked By: Date: 07/12/2016 Job No. 16-164 Sheet No. JA200D Plotted: Fri, Aug 05 2016 c6 x U i U A a � 4 0 0 W O �� O W a�� s- Cf)M N W �U� 'o x o p �D �r a w UxC CO a Lr) 0 0 Sheet Title DEMO PLAN Status: SUBMITTAL SET Drawn By: TLH Checked By: Date: 07/12/2016 Job No. 16-164 Sheet No. JA200D Plotted: Fri, Aug 05 2016 m C O CC 41 r T C E N m C yE co CO 0CD m 8 V O O a) C O C Z� ro d C N C a)aoc=�a)�. Team CO m N O D U C C �' 8 t In a° co E o =FL- Ezo M aaa)) m 0.0mmin o 3 ICL O) a) ..`O ZTtC (A c -0in v, m m Tv a� O C mWarnc O O V O a) X C IC 'p a) Za)wES= M C O r M 7 r+ O N r ^ Y C T C a to t M O i� z Sheet Title OVERALL 1ST FLOOR PLAN Status: SUBMITTAL SET Drawn By: TLH Checked By: Date: 07/12/2016 Job No. 16-164 Sheet No. A201 L- I Plotted: Fri, Aug 05 2016 06 1 x U U A a � x 4 Sheet Title OVERALL 1ST FLOOR PLAN Status: SUBMITTAL SET Drawn By: TLH Checked By: Date: 07/12/2016 Job No. 16-164 Sheet No. A201 L- I Plotted: Fri, Aug 05 2016 2 3 ELECTRICAL NOTES: ALL ELECTRICAL OUTLET SHOWN ARE NEW. EXISTING ELECTRICAL OUTLETS & LUMINARIES IN UNALTERED ROOMS ARE TO REMAIN. LLJLlV[ 11 I.:JL V V l Y. -. l FOR GARBAGE DISPOSAL 5 DEDICATED OUTLET FOR DISHWASHER ELECTRICAL, LIGHTING & SWITCHING PLAN 1 1 2 1 3 14 5 0 6 7 I (E) 7 18 1/4"=l' -O" I 10 1 11 1 12 1 13 1 14 f 15 1 16 ELECTRICAL NOTES W.H. EXISTING 53 GAL, NATURAL GAS, WATER HEATER, 40,000 BTU WATER HEATER NOTES: SEISMIC STRAPS: TWO SEISMIC STRAPS ARE REQUIRED PER C.P.C. 507.2; ONE LOCATED WITHIN THE TOP 1/3 OF THE WATER HEATER AND ONE AT THE BOTTOM 1/3. THE BOTTOM STRAP MUST BE LOCATED AT LEAST 4" AWAY FROM THE WATER HEATER CONTROLS. VENTING (CPC 510.6.1.1, 510.7.4.1, 510.10): ALL VENT PIPING THAT RUNS THROUGH THE CEILINGS, FLOORS, OR WALLS SHALL BE DOUBLE WALL METAL PIPE. THE VENT AND THE WATER HEATER MUST MAINTAIN CLEARANCE FROM COMBUSTIBLE MATERIALS (SUCH AS WALL FRAMING OR ROOFING) AS REQUIRED BY THE MANUFACTURER, WHICH IS TYPICALLY 1" MINIMUM. THE VENT SHALL TERMINATE A MINIMUM V ABOVE ROOF, BE INSTALLED WITH FLASHING THROUGH THE ROOF, < AND TERMINATE IN A LISTED AND APPROVED VENT CAP. VENTS SHALL ALSO TERMINATE A MINIMUM OF 3' ABOVE ANY BUILDING OPENING (DOOR, OPERABLE WINDOW, ETC.) WITHIN 3' OF THE TERMINATION. VENTING SHALL EXTEND IN A GENERAL VERTICAL DIRECTION WITH OFFSETS NOT EXCEEDING 45 DEGREES, EXCEPT ON 60 DEGREE OFFSET IS PERMITTED. VENTS MAY REQUIRE ADDITIONAL SUPPORTS DEPENDING ON THE MATERIAL AND DESIGN. PRESSURE -TEMPERATURE RELIEF VALVE (CPC 608.5) : ALL WATER HEATERS HAVE A PRESSURE/TEMPERATURE (P/T) RELIEF VALVE THAT IS GALVANIZED STEEL, HARD -DRAWN COPPER, OR CPVC. THE VALVE SHALL BE DRAINED TO THE EXTERIOR, TERMINATE TOWARD THE GROUND MAINTAINING BETWEEN 6" AND 24" OF CLEARANCE FROM THE GROUND, AND POINT DOWNWARD. THE DIAMETER OF THE VALVE OPENING (GENERALLY 3/4") MUST BE MAINTAINED TO THE TERMINATION OF THE DRAIN. RELIEF VALVE DRAINS SHALL NOT TERMINATE IN A CRAWL SPACE OR AN OVER -FLOW PAN. NO PART OF SUCH DRAIN PIPE SHALL BE TRAPPED OR SUBJECT TO FREEZING, AND THE TERMINAL END OF THE DRAIN SHALL NOT BE THREADED. WHEN APPROVED BY THE CHIEF BUILDING OFFICIAL, SUCH DRAIN MAY TERMINATE AT OTHER LOCATIONS (I.E. LAUNDRY TUB, FLOOR SINK, OR FLOOR DRAIN). LOCATED IN A BEDROOM, BATHROOM, OR BEDROOM CLOSET (CPC 504.1): IF LOCATED IN A BEDROOM, BATHROOM, OR BEDROOM CLOSET, THE WATER HEATER SHALL BE LOCATED IN A CLOSET PROVIDED WITH A LISTED SELF-CLOSING, GASKETED DOOR AND ALL COMBUSTION AIR SHALL BE OBTAINED FROM OUTDOORS. THE WATER HEATER CLOSET SHALL NOT BE USED FOR ANY OTHER PURPOSE. COMBUSTION AIR (CPC 506) : COMBUSTION AIR MUST BE MAINTAINED PER THE CALIFORNIA PLUMBING CODE. WHEN THE APPLIANCE IS LOCATED IN AN UNCONFINED SPACE (E.G. GARAGE) THE COMBUSTION AIR CAN BE USED FROM THAT AREA. WHEN LOCATED IN A CLOSET, COMBUSTION AIR MUST BE PROVIDED AT A MINIMUM OF TWO OPENINGS (ONE WITHIN 12" OF THE TOP OF THE WATER HEATER AND ONE WITHIN 12" OF THE BOTTOM) SIZED AT 100 SQUARE INCHES EACH. �j SEDIMENT TRAP (CPC 1211.8) : A SEDIMENT TRAP SHALL BE INSTALLED ON THE GAS LINE t DOWNSTREAM OF THE APPLIANCE SHUT-OFF VALVE AND AS CLOSE TO INLET OF THE \-FOUIPMENT AS PRACTICAL. RESIDENTIAL INDOOR -MR QUALITY -AND MECHANICAL VENTILATION A OUORC 04n.,.4.,.4 A)') 7�1,1e 7 4 Table 7.1 Prescriptive Duct Sizing Requirements KITCHEN AREAS PER 210-12 OF THE 2013 CEC. A Duct Type Flex Duct ELECTRICAL CODE. Smooth Duct ALL WIRE SHALL BE INSTALLED IN WALL STUD BAYS OR ATTIC WHEN POSSIBLE. Fan Rating cfm @ 0.25 50 in. w.g. 80 100 125 50 FROM ANY OUTLET. THIS APPLIES TO ANY WALL OVER 2'-0" IN LENGTH. ALL OUTLET TO BE 80 100 125 Maximum Allowable Duct Length (ft) B ALL OUTDOOR OUTLETS SHALL BE GFCI AND PROVIDE WEATHER PROTECTION (I.E. Diameter, (in) Flex Dud BUBBLE COVERS) PER 2013CEC ART. 210.8(A)(3) AND 406.9(A) & (B) 1 Smooth Duct ALL WIRE L BE 12 GA. OPPER. TA L ON AMP CIRCUIT WITH 3 X X X X 5 X. X X 4 70 3 X X 105 35 5 X 5 NL 70 35 20 NL 135 85 55 6 NL NL 125 95 NL NL NL 145 7andabove NL NL NL NL NL NL NL NL This table assumes no elbows. Deduct 15 ft of allowable duct length for each tum, elbow, or fitting. ZLUMINARIES - MANDATORY MEASURES NL = no limit on duct length of this size ALL LIGHTING SHALL CONFORM TO THE MANDATORY MEASURES FOR RESIDENTIAL FORM MF LIGHTING: CALIFORNIA ENERGY COMMISSION, MANDATORY MEASURES, -1R. X = not allowed, any length of duct of this size with assumed turns, elbows, fittings will exceed the rated pressure drop > PERMANENTLY INSTALLED LUMINARIES INSTALLED IN THE LAUDRY/UTILITY ROOM SHALL SOUND RATING AND CONTINUOUS OPERATION THE WHOLE -BUILDING VENTILATION EXHAUST FAN WILL OPERATE CONTINUOUSLY, AND IS REQUIRED TO BE RATED FOR SOUND AT A MAXIMUM OF 1 SONE. THIS EXHAUST FAN CAN BE CONTROLLED BY A STANDARD ON/OFF SWITCH, BUT THE SWITCH MUST BE LABELED TO INFORM THE OCCUPANT THAT THE EXHAUST FAN IS THE WHOLE -BUILDING VENTILATION EXHAUST FAN AND IS INTENDED TO OPERATE CONTINUOUSLY. NO SPECIFIC WORDING IS MANDATED, BUT THE WORDING NEEDS TO MAKE CLEAR WHAT THE CONTROL IS FOR AND THE IMPORTANCE OF OPERATING THE SYSTEM. THIS MAY BE AS SIMPLE AS "VENTILATION CONTROL" OR MIGHT INCLUDE WORDING SUCH AS: "OPERATE WHEN THE HOUSE IS IN USE" OR "KEEP ON EXCEPT WHEN GONE OVER 7 DAYS" OR "FAN IS TO BE LEFT ON TO ENSURE INDOOR AIR QUALITY." NEW WHOLEHOUSE FAN WHOLE HOUSE FAN ATTIC VENTILATION WHEN INSTALLING A WHOLE HOUSE FAN THE ATTIC VENTILATION OPENING MUST BE PROVIDED OR VERIFIED TO MEET THE MANUFACTURE'S RECOMMENDATION SPECIFICATIONS OR COMPLY WITH THE ENERGY CODE SECTION 150.1(C)12B. (I.E. HAVE AT LEAST 1 -SF OF ATTIC FREE VENTILATION PER 375 -CFM OF THE RATED WHOLE HOUSE FAN AIR FLOW M ARC FAULT CIRCUIT -INTERRUPTER TO BE INSTALLED IN BEDROOMS, LAUNDRY AND KITCHEN AREAS PER 210-12 OF THE 2013 CEC. ALL PORTIONS OF THIS DRAWING ARE SUBJECT TO THE 2013 EDITION OF THE CALIFORNIA ELECTRICAL CODE. ALL WIRE SHALL BE INSTALLED IN WALL STUD BAYS OR ATTIC WHEN POSSIBLE. ONLY SPECIAL OUTLETS HAVE BEEN DEPICTED ON THIS PLAN. GENERAL CONVENIENCE OUTLETS SHALL BE INSTALL SO THAT NO POINT ON ANY WALL IS MORE THAN 6-0" AWAY FROM ANY OUTLET. THIS APPLIES TO ANY WALL OVER 2'-0" IN LENGTH. ALL OUTLET TO BE PLACED MIN. 12" A.F.F. FOR ADDITIONAL INFORMATION SEE ARTICLE 210-52 OF THE 2013 CEC. ALL OUTDOOR OUTLETS SHALL BE GFCI AND PROVIDE WEATHER PROTECTION (I.E. BUBBLE COVERS) PER 2013CEC ART. 210.8(A)(3) AND 406.9(A) & (B) ALL WI SHALL 12 GA. COPPER. INSTALL ALL 0 P CIRCUIT WITH MAXIMUM NUMBER OF OUTLETS ON ANY GIVEN CIRCUIT NOT TO EXCEED 12. SPECIAL APPLIANCES ARE SHOWN WITH A SINGLE OUTLET SYMBOL AND SHALL BE SERVED BY A DEDICATED CIRCUIT ALL ELECTRICAL BOXES SHALL BE PLASTIC NAIL ON TYPE. IF THE CONTRACTOR CHOOSES TO USE METAL BOXES FOR A SPECIFIC LOCATION, THE BOX SHALL BE GROUNDED IN COMPLIANCE WITH THE C.E.C. PROVIDE 1 1/4 P.V.C. CONDUIT STUBBED THROUGH THE PLATE LINE & ATTACHED TO A ROOF RAFTER FOR ALL LOW VOLTAGE OUTLETS. (PHONE AND TV) PROVIDE FOR 6 PHONE JACKS AND 6 T.V. OUTLETS.. LOCATION TO BE DETERMINED BY OWNER. ARC FAULT CIRCUIT -INTERRUPTER TO BE INSTALLED IN BEDROOMS, LAUNDRY AND KITCHEN AREAS PER 210-12 OF THE 2013 CEC. A ALL PORTIONS OF THIS DRAWING ARE SUBJECT TO THE 2013 EDITION OF THE CALIFORNIA ELECTRICAL CODE. ALL WIRE SHALL BE INSTALLED IN WALL STUD BAYS OR ATTIC WHEN POSSIBLE. ONLY SPECIAL OUTLETS HAVE BEEN DEPICTED ON THIS PLAN. GENERAL CONVENIENCE U a� x U OUTLETS SHALL BE INSTALL SO THAT NO POINT ON ANY WALL IS MORE THAN 6-0" AWAY FROM ANY OUTLET. THIS APPLIES TO ANY WALL OVER 2'-0" IN LENGTH. ALL OUTLET TO BE A PLACED MIN. 12" A.F.F. FOR ADDITIONAL INFORMATION SEE ARTICLE 210-52 OF THE 2013 CEC. B ALL OUTDOOR OUTLETS SHALL BE GFCI AND PROVIDE WEATHER PROTECTION (I.E. BUBBLE COVERS) PER 2013CEC ART. 210.8(A)(3) AND 406.9(A) & (B) 1 ALL WIRE L BE 12 GA. OPPER. TA L ON AMP CIRCUIT WITH MAXIMUM NUMBER OF OUTLETS ON ANY GIVEN CIRCUIT NOT TO EXCEED 12. SPECIAL APPLIANCES ARE SHOWN WITH A SINGLE OUTLET SYMBOL AND SHALL BE SERVED BY A DEDICATED CIRCUIT ALL ELECTRICAL BOXES SHALL BE PLASTIC NAIL ON TYPE. IF THE CONTRACTOR CHOOSES TO USE METAL BOXES FOR A SPECIFIC LOCATION, THE BOX SHALL BE GROUNDED IN COMPLIANCE WITH THE C.E.C. C PROVIDE 1 1/4" P.V.C. CONDUIT STUBBED THROUGH THE PLATE LINE & ATTACHED TO A ROOF RAFTER FOR ALL LOW VOLTAGE OUTLETS. (PHONE AND TV) PROVIDE FOR 6 PHONE JACKS AND 6 T.V. OUTLETS.. LOCATION TO BE DETERMINED BY OWN R. ZLUMINARIES - MANDATORY MEASURES ALL LIGHTING SHALL CONFORM TO THE MANDATORY MEASURES FOR RESIDENTIAL FORM MF LIGHTING: CALIFORNIA ENERGY COMMISSION, MANDATORY MEASURES, -1R. > PERMANENTLY INSTALLED LUMINARIES INSTALLED IN THE LAUDRY/UTILITY ROOM SHALL D BE HIGH EFFICACY AND CONTROLLED BY A VACANCY SENSOR. PERMANENTLY INSTALLED LUMINARIES IN THE NEW BATHROOM SHALL MEET THE FOLLOWING REQUIREMENTS: a. A MINIMUM OF ONE HIGH EFFICACY LUMINAIRE SHALL BE INSTALLED IN EACH BATHROOM; AND b. ALL OTHER LIGHTING INSTALLED IN EACH BATHROOM SHALL BE HIGH EFFICACY OR CONTROLLED BY VACANCY SENSORS. 2013 CEC SECTION 150(1,)5 PERMANENTLY INSTALLED LUMINARIES IN KITCHENS SHALL BE HIGH EFFICACY LUMINARIES. UP TO 50% OF THE WATTAGE, AS DETERMINED IN SECTION 130(c), OF PERMANENTLY INSTALLED LUMINARIES IN KITCHENS MAY BE IN LUMINARIES THAT ARE E NOT HIGH EFFICACY LUMINARIES, PROVIDED THAT THESE LUMINARIES ARE CONTROLLED BY SWITCHES SEPARATE FROM THOSE CONTROLLING THE HIGH EFFICACY LUMINARIES. LUMINARIES PROVIDING OUTDOOR LIGHTING AND PERMANENTLY MOUNTED TO A RESIDENTIAL BUILDING OR TO OTHER BUILDINGS ON THE SAME LOT SHALL BE HIGH EFFICACY LUMINARIES (NOT INCLUDING LIGHTING AROUND SWIMMING POOLS/WATER FEATURES OR OTHER ARTICLE 680 LOCATIONS) OR ARE CONTROLLED BY OCCUPANT SENSORS WITH INTEGRAL PHOTO CONTROL CERTIFIED TO COMPLY WITH SECTION 119(d). WALL EQUIPMEN ING` S SINGLE POLE LIGHT SWITCH. QUIET STYLE AS MFR. BY LEVITON OR EQUAL. COLOR BY OWNER. F S3 3 WAY LIGHT SWITCH. COLOR BY OWNER STANDA D T ERE S ANT DUPLEX RECEPTACLE (MAX 8 RECEPTACLES PER CIRCUIT). ALL 125 -VOLT, SINGLE PHASE, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED AS TAMPER-RESTISTANT RECEPTACLES (NEW OUTLETS ONLY) 22z N. 30 AMP 220 volt REC ACLE --e SINGLE OUTLET RECEPTACLE (DEDICATED CIRCUIT) GFCI� G.F.C.I. OUTLET JUNCTION BOX SME DETECTOR WITH BATTERY BACK UP C �P HARD WIRED CARBON MONOXIDE DETECTOR WITH BATTERY BACK UP 0 DOOR BELL SWITCH © DOORBELL CHIME CEILING MOUNTED EXHAUST FAN. EACH EXHAUST FAN SHALL PROVIDE A MINIMUM VENTILATION RATE OF 50CFM, WITH A DUCT DIAMETER AND MAXIMUM DUCT LENGTH ACCORDING TO ASHRAE STANDARD 62.2 TABLE 7.1. BATHROOM FANS MUST BE CONTROLLED BY A HUMIDSTATE CONTROL CAPABLE OF ADJUSTMENT BETWEEN A RELA U F80°/201 BSC SECTION 4.506 H Local Exhaust Bathroom Ventilation Rate Summary Enter the required fan flow rate (cfm). oBathroom Fan Flow(cfm)= 50 (#of Bathrooms 2 Use the fan flow rate from this summary for selection of the local ventilation fan and for the duct design for the local ventilation system from Table 7.1. o Duct Size(in)= 51t o Maximum Allowable Duct Length (ft) = 35 1� KITCHEN EXHAUST FAN. EACH EXHAUST FAN SHALL PROVIDE A MINIMUM VENTILATION RATE OF 100CFM, WITH A DUCT DIAMETER AND MAXIMUM DUCT LENGTH ACCORDING TO ASHRAE STANDARD 62.2 TABLE 7.1. THE EXHAUST HOOD IS TO BE VENTED THROUGH THE ROOF. A METAL, SMOOTH INTERIOR DUCT IS REQUIRED. PROVIDE A BACK DRAFT DAMPER PER CMC 504.2. Local Exhaust Kitchen Ventilation Rate Summary Enterthe required fan flow rate (cfm). oKitchen Fan Flow (cfm)=__j_00(# of Kitchens 1 Use the fan flow rate from this summary for selection of the local ventilation fan and for the duct design for the local ventilation system from Table 7.1. 5.. o Duct Size(in)= j5 o Maximum Allowable Duct Length (ft) INTERIOR WALL MOUNTED LIGHTING FIXTURE 1 �J EXTERIOR WALL MOUNTED FLUORESCENT LIGHTING FIXTURE (SWITCHED) SURFACE MOUNTED CEILING LIGHT ( LIGHT SYMBOL MAY BE DEPICTED OFF CENTER IN DRAWING FOR CLARITY) cz::)OO � CEILING FAN WITH LIGHT FIXTURE &12 K !✓��� ��� PLUMBING EQUIPMENT PERMIT BUTTF COUNTY C)EVELOFMENT SERVICES REVIEWED FOR CODE COMPLIANCE OEXISTING 53 GAL, NATURAL GAS, WATER HEATER, 40,000 BTU/ �-�-F3y NOTES & LEGEND NO SCALE 9 10 11 12 13 NOTES & LEGEND 14 15 1 16 NO SCALE CO 3 n.c cam m 0' 7Z °? EaNio w m cam c';c . :5 a m c E.°� inmE U.N- . 8 CL C� E �O o c >'3Z �•�c :co..ONLmL0m3 •Oan oCic mCm�NZt'Ecca a.m ca CL p �cucc-m, �Ndtp>, U n N LUm L cn L, -2E2 �Eoo, „ z axi cuLE 12 E a) cd 0 w ->. ca���ocrn ca U) m c c tai m r a— cd ca a'p, c ti 0 o V 0 m x C rd 'D m Z 6 c S.6 mLu E SJ N O Y N r N 0 0 W o Z�O CN 0 ��� �1, O z o 4-1 rw►� � � i� C-) '0 x o �_4 a W Ux o CO a Lo 0 0 Sheet Title ELECTRICAL LIGHTING AND SWITCHING PLAN Status: SUBMITTAL SET Drawn By: TLH Checked By: Date: 07/12/2016 Job No. 16-164 Sheet No. A2 6 0 Plotted: Fri, Aug 05 2016 00 U a� x U A a C� 0 0 W o Z�O CN 0 ��� �1, O z o 4-1 rw►� � � i� C-) '0 x o �_4 a W Ux o CO a Lo 0 0 Sheet Title ELECTRICAL LIGHTING AND SWITCHING PLAN Status: SUBMITTAL SET Drawn By: TLH Checked By: Date: 07/12/2016 Job No. 16-164 Sheet No. A2 6 0 Plotted: Fri, Aug 05 2016 CI DI EI HI KI 1 2 3 4 5 6 7 g g 10 11 12 1 13 1 14 1 i� Compliance Margin Percent Improvement 04 City Durham 05 Standards Version Compliance 2015 06 Zip Code 95938 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 06 Climate Zone CZ111 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 90 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Gond. Floor Area (ft2) 1478 15 Number of Zones 1 16 Stab Area (ft2) 0 17 A CFIR-PRF-01 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD GF1R-PRF-01 OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-0i CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Page 3 of 6 CERTIFICATE Calculation Date/Time: 14:53, Thu, Aug 04, 2016 g Calculation DateITime: 14:53, Thu, Aug 04, 2016 Page 1 of 6 Project Name: Residential Building Calculation DateiTime: 14:53, Thu, Aug 04, 2016 Page 2 of 6 Project Name: Residential Building Project Name: Residential Building Input File Name: george, keith remodel, REV B.xml f t' D t`on• Title 24 Anal sir Input File Name: george, keith remodel, REV B.xml Calculation Description: Title 24 Analysis p g g Calculation Description: Title 24 Analysis Input File Name: george, keith remodel, REV B.xml Calcu a on es_ 1, i y GENERAL INFORMATION 01 ENERGY USE SUMMARY 01 Project Name Residential Building 04 05 02 Calculation Description Title 24 Analysis 08 Energy Use (kTDVlft2-yr) 03 Project Location 9533 Cummings Lane Compliance Margin Percent Improvement 04 City Durham 05 Standards Version Compliance 2015 06 Zip Code 95938 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 06 Climate Zone CZ111 09 Software Version EnergyPro 6.6 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 90 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Gond. Floor Area (ft2) 1478 15 Number of Zones 1 16 Stab Area (ft2) 0 17 Number of Stories 1 18 Addition Cond. Floor Area 0 19 Natural Gas Available Yes 1 20 Addition Slab Area (ft2) 0 21 Glazing Percentage (%) 9.8% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building DOES NOT require HERS Verification REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. NO SPECIAL FEATURES REQUIRED HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications- - - None -- Cooling System Verifications- -None-- WAC one-- HVAC Distribution System Verifications: -None -- Domestic Hot Water System Verifications: -None -- ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDVlf2-yr)* 260.83 256.34 4.49 1.7% * includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 ENERGY USE SUMMARY 03 04 04 05 06 07 08 Energy Use (kTDVlft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 66.78 65.53 1.25 1:9% Space Cooling 121.21 120.17 1.04 0.9% IAQ Ventilation 0.00 0.00 0.00 0.0°1° Water Heating 16.53 14.33 2.20 13.3% Photovoltaic Offset -- 0.00 0.00 - Compllance Energy Total 204.52 200.03 4.49 22% REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. NO SPECIAL FEATURES REQUIRED HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications- - - None -- Cooling System Verifications- -None-- WAC one-- HVAC Distribution System Verifications: -None -- Domestic Hot Water System Verifications: -None -- ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDVlf2-yr)* 260.83 256.34 4.49 1.7% * includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Residential Building 1478 1 3 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 First Floor Conditioned HVAC Systeml 1478 9 DHW Sys 1 East Wall OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft2) Titt (deg) Status Verified Existing Condition East Wall First Floor Default Wall Prior to 197 90 Front 465.8 99.5 90 Existing No South Wal First Floor Default Wall Prior to 197 180 Left 269.2 8.5 90 Existing No West Wall First Floor Default Wall Prior to 197 270 Back 465.6 53.5 90 Existing No North Wall First Floor Default Wall Prior to 197 0 Right 269.2 43 90 Existing No Roof First Floor Default Roof Prior to 197 Insect Screen (default) Insect Screen (default) New Existing 1478 2x4 @ 16 in. O.C. Existing No - Inside Finish: Gypsum Board - Cavity /Frame: no insul. / 2x4 - Exterior Finish: Wood Siding/sheathing/decking Floor Default FloorCrawispace Wood Framed Ceiling 1478 R 11 0.083 Existing No Raised FloorFirst ATTiC 01 02 03 04 05 06 07 08 09 10 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Statu s Verified Existing Condition First Floor Attic RoofFirst Floor Ventilated d 0.1 0.85 No No ExistAttic ng No WINDOWS 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) Height (ft) Multiplie r Area (ft2) U- factor SHGC Exterior Shading Status Verified Existing Condition Window East Wall (Front -90) -- - 1 79.5 0.58 0.65 Insect Screen (default) Existing No Window 2 South Wall (Left -180) - - 1 8.5 0.58 0.65 Insect Screen (default) Existing No Window 3 West Wall (Back -270) - -- 1 26-0 ✓ 0.58 0.65 Insect Screen (default) Existing No Window (New) Window 4 West Wall (Back -270) North Wal (Right -0) - - -- -- 1 1 7.5 ✓ 23.0 0.34 0.58 0.34 0.65 Insect Screen (default) Insect Screen (default) New Existing N/A No Re Istration Date/Time: HERS Provider: Registration Number: Registration Date/Time: HERS Provider: Registration Number, Registration Date/Time: HERS Provider: Registration Number. g Report Generated at:2016-08-0414:54:31 R 4072016-744 Report Generated at: 2016-08-0414:34:31 CA Building Energy Efficiency Standards -2013 Residential Compliance Report Version - CFSR-04072016.744 Report Generated at: 2016-08-0414:54:31 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFIR-04072016-744 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFl -0 � CFIR-PRF-01 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFiR-PRF-01 CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CFIR-PRF-01 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Page 6 of 6 Calculation Date/Time: 14:53, Thu, Aug 04, 2016 Page 5 of 6 Protect Name: Residential Building Calculation Date/Time: 14:53, Thu, Aug 04, 2016 ff Project Name: Residential Building Calculation Date/Time: 14:53, Thu, Aug 04, 2016 Page 4 of 6 Project Name: Residential Building • Titl 24 An I Input File Name: george, keith remodel, REV B.xml Calculation Description: Title 24 Analysis Input File Name: george, keith remodel,. REV B.xml 24 I ' Input File Name: george, keith remodel, REV B.xml Calculation Description. e a ysns Calculation Description. Titi e Ana ysls DOORS 01 02 03 04 01 06 02 03 04 05 06 Name Compact Distribution Side of Building Area (ft2) U -factor Status Verified Existing Condition Door DHW Sys 1 East Wall 20.0 0.50 Existing No Door (New) Door 2 n/a West Wall North Wall 20.0 0.50 New No 20.0 0.50 Existing No Heating Component 1 No Cooling Component 1 No - none - OPAQUE SURFACE CONSTRUCTIONS 1478 Existing No Zonally Controlled 02 03 HERS Verification 04 05 O6 07 Q1 Construction Name Surface Type Construction Type N/A Framing Total Cavity R -value Winter Design U -value Assembly Layers Attic Roofs Wood Framed Ceiling 2x4 Top Chord of Roof Truss @ 24 in. O.C. none 0.644 - Cavity/ Frame., no insul. / 2x4 Top Chrd - Roof Deck Wood Siding/sheathing/decking - Roofing: Light Roof (Asphalt Shingle) Attic RoofFirst Floor Default Floor Crawlspece Floors Over Crawlspace Wood Framed Floor Default 0 2x12 @ 16 in. O.C. none 0216 - Floor Surface: Carpeted - Floor Deck: Wood Sidinglsheathingldecking - Cavity/Frame: no insul. / 2x12 Default Wall Prior to 197 Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.302 - Inside Finish: Gypsum Board - Cavity /Frame: no insul. / 2x4 - Exterior Finish: Wood Siding/sheathing/decking Default Roof Prior to 197 Ceilings (below attic) Wood Framed Ceiling 2x4 @ 16 in. O.C. R 11 0.083 - inside Finish: Gypsum Board - Cavity/Frame: R-9.9 /2x4 Over Floor Joists: R -f.9 insul. WATER HEATING SYSTEMS 01 02 03 04 05 06 07 OS System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) Status Verified Existing Condition Name DHW Sys 1 WATER HEATERS 01 DHW 02 Standard 03 DHW Heater 1 04 05 1 Annual New No O6 07 OS Heater Element Type Natural Gas Tank Type Small Storage Tank Volume (gal) 50 Energy Factor or Efficiency 0.67 EF Input Rating 40000-Btuthr Tank Exterior Insulation R -value 0 Standby Loss (Fraction) 0 Name DHW Heater 1 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1 n/a n/a n/a n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 WeliFurnaceGrovity - Ductless gravity flowed wall furnace System Type Heating System Name Ducted Cooling System Name Ducted Distribution System Fan System Floor Area Served Status Verified Existing Condition Name HVAC Sysieml other Heating and Cooling System Heating Component 1 No Cooling Component 1 No - none - HVAC Fan 1 1478 Existing No HVAC - HEATING SYSTEMS 1.1 certify that this Certificate of Compliance documentation is accurate and complete. i r' Documentation Author Name: Documentation Author Signature: �- 01 02 03 Name Type Efficiency Heating Component 1 WeliFurnaceGrovity - Ductless gravity flowed wall furnace 63 AFUE aty/srate3anta Rosa, California 95402 Phone: t• 707-237-6957 RESPONSIBLE PERSON'S DECLARATION STATEMENT HVAC • COOLING SYSTEMS am 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, 02 Responsible Designer Name: 03 04 05 06 07 01 System Type license: Efficiency EER SEER Zonally Controlled City/State/Zip: Multi -speed Compressor HERS Verification Name NoCooling - No cooling equipment N/A N/A No No N/A Cooling Component 1 IAQ (Indoor Air Quality) FANS 01 02 03 04 OS Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVenffW 0 Default 0 Not Required DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1.1 certify that this Certificate of Compliance documentation is accurate and complete. i r' Documentation Author Name: Documentation Author Signature: �- Rick Rocklewitz w Company:. Signature Date: NRG Compliance, LLC 8/4/2016 CEA/HERS Certification Identification (If applicable): Address: PO Box 3777 aty/srate3anta Rosa, California 95402 Phone: t• 707-237-6957 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. am 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Larry Coffman Company: Date Signed: North Star Address: license: 111 Mission Ranch Blvd Ste 100 City/State/Zip: Phone: Chico, CA 95926 5308931600 HERS Provider: Registration Number: Registration Date/Time: : HERS Provider: Registration Number: Registration Date/Time: titKS rroviaer: Registration Number: Registration Date/Time: Report Generated at: 2016-08-0414:54:31 Report Generated at: 2016-D8-0414:54:31 CA Building Energy Efficiency Standards- 2013 Residential Compliance Report Version -CFIR-04072016-744 Report Generated at: 2016-08-0414:54:31 CA Building Energy Efficiency Standards -2013 Residential Compliance Report Version -CFIR-04072016-744 p CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFSR-04072016-744 4 E 12 �IV�1�1.7fY l,aiL�.UL1",1lUlV� 9 t0 11 12 13 14 L 5 6 7 8 4 IB IC ID IE F 4 IG IH 1J IK PERMIT # BUTTE COUNTY DEVELOPMENT SE VICES REVIEWED FOR CODE COMPLIANCE DATE= - - L NO SCALE 15 16 N C >^ l0 T V E mtG p L„ C a, C `y C Na Y N 'd o y E-.' p2c0 t0�0o= E =� aC oL-0 E¢ o � rnrn- > 3Z o-0 a.��ro'�CL c�=5)0 ani sort o a�roYW rn N m o a v T `) c8 in CU N - C 7 (O N N $Cn oo 6.0E o 9F- EZ rn a�ai o 0 3 o E v. Y m.0 O LA in a) CD U 'O -p O r rn E C_ C d N 0 a� m m aII'm'v CO Z 0 °c r_.6 ow E S' o 0 o � E N r q c St c r I� T O � z Sheet Title ENERGY CALCULATIONS Status: SUBMITTAL SET Drawn By: TLH Checked By: Date: 07/12/2016 Job No. 16-164 Sheet No. EC -1 Plotted: Fri, Aug 05 2016 00 .-i U a> U a� A � 4 Sheet Title ENERGY CALCULATIONS Status: SUBMITTAL SET Drawn By: TLH Checked By: Date: 07/12/2016 Job No. 16-164 Sheet No. EC -1 Plotted: Fri, Aug 05 2016 4