Loading...
HomeMy WebLinkAboutB16-1766 039-370-097BUTTE COUNTY AREA DEPARTMENT OF DEVELOPMENT SERVICES 5 INSPECTION CARD MUST BE ON JOB SITE 24 Hour Inspection Line (IVR) : 530.538.4365 (Cut off time for inspections is 2pm) Development Services cannot guarantee inspections on the date requested Office: 530.538.7601 Fax:530.538.7785 www.ButteCountv.net/dds Permit No: B16-1766 Issued: 8/15/2016 APN: 039-370-097 Address: 1329 STANLEY AVE, CHICO Owner: SWANSON THURSTON PAUL & CONNIE Permit Type: RE -ROOF RESIDENTIAL Description: REROOF Flood Zone: None SRA Area: No Front: Centerline of Road: Rear: SRA: Side: AG: Other: Total Setback from Centerline of Road: ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING Inspection Type IVR INSP DATE Setbacks 131 Foundations / Footings 111 Pier/Column Footings 122 Eufer Ground 216 Masonry Grout 120 Setbacks 1 EA Do Not Pour Concrete Until Above are Signed Pre -Slab 124 Gas Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing 149 Underfloor Ducts 319 Shear Transfer 136 Under Floor Plumbing 412 Under Slab Plumbing 411 Blockin /Unde inin 612 Tiedown/Soft Set System 611 Do Not Install Floor Sheathing or Slab Until Above Signed ShearwallB.W.P.-Interior 134 ShearwallB.W.P.-Exterior 135 Roof Nail/Drag Trusses 129 417 Manometer Test Do Not Install Siding/Stucco or Roofing Until Above Signed Rough Framing 153 Rough Plumbing 406 Rough Mechanical 316 Rough Electrical 208 4 -Way Rough Framing 128 Gas Piping House 403 Gas Test House 404 Shower Pan/Tub Test 408 Do Not Insulate Until Above Signed Permit Final 802 Electrical Final 803 Mechanical Final 809 Plumbing Final 813 Fire Sprinkler Test or Final 702 Swimming Pools Inspection Type IVR INSP DATE T -Bar Ceiling 145 Stucco Lath 142 Swimming Pools Setbacks 131 Pool Plumbing Test 504 Gas Test 404 . Pre-Gunite 506 Pre -Deck 505 Pool Fencing/Alarms/Barriers 1 503 Pre -Plaster 1 507 Manufactured Homes Setbacks 131 Blockin /Unde inin 612 Tiedown/Soft Set System 611 Permanent Foundation System 613 Underground Electric 218 Sewer 407 Underground Water 417 Manometer Test 605 Continuity Test 602 Skirting/Steps/Landings 610 Coach Info Manufactures Name: Date of Manufacture: Model Name/Number: Serial Numbers: Length x Width: Insignia: Finals: Public Works Final 538.7681 Fire De artment/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final 'PROJECT FINAL .� =rroject Final is a Certificate of Occupancy foi'(Residential Only) PERMITS BECOME NULL AND \'OII) I YEAR FROiNI THE DATE OF ISSLJ,\NCF. IF NYORK HAS COiMINIENCED. YOU MAY PAY FOR A 1 YEAR RENEWAL 30 DAYS PRIOR TO EXPIRATION s Butte County Department of Development Services-� TIM SNELLINGS, DIRECTOR I PETE CALARCO, ASSISTANT DIRECTOR�,sr 7 County Center Drive ,. Oroville, CA 95965 (530) 5384601 Telephone I `tel ( ji(n ry (530) 538-7785 Facsimile 1 (( (� �(/ • • ADMINISTRATION " BUILDING ` PLANNING OEY4;LOF4IENT SERVICES 3� COOL REROOF INFORMATION SHEET Project Address - Slope of Roof q # of Existing Layers �_ Existing Roofing Material ;he all that apblies to NEW roof: Composition ❑ Tile r103 Shake o Wood Shingle a Built up ❑ Bitumen Metal ❑ Other Tear off existing ❑ Overlay New Sheathing ❑ The California. Energy Commission (CEC) has adopted new requirements for re -roofing. projects. Beginning January 1, 2010 when more than 50% of the exterior surface of the roof or more than 1,000 -sq. ft. of roof is replaced, whichever is Jess, the new roofing area must meet the roofing product 'CoolRoof requirements of§152(b)1Hi, 152(b)1Hii, or 152(b)1 HiiL For roof slopes of greater than 2:12: -------------------:----- INSTRUCTIONSFOR COMMERCIAL PROJECTS ------------------- -_ • Commercial roofs on decks with a slope of 2:12 or less must meet the 2008 Building Energy Effiidency Standards by being a certified Cod Roof. A coov of the standards signed by the aoaficant must accompianvthis -adalication • Overlays that exceed 100 pounds per square must be accompanied by calculations performed by a California licensed Civil or StriUctural Engineer. All overlays must be approved by the Building Offiicial and other requirements listed within Appendix Chapter 15, Cafifomia Building Code. • A specification from the roofing manufacturer must accompany this aaolication The specification should list the fire class of the material, a description of the materials layers that mu a installed, the Cool Roof certification (if required because of the slope of the roof), and installation requirements. ■ Packaging mat rials w RRC la Is mus left on the job site to demonstrate compliance with the specification for the cool roof rating if applicable. 1 agree that the info tm vid �n t is d nt is accurate and true. Applicants Signatur Date: f Butte County Department of Development Services TIM SNELLINGS, DIRECTOR I PETE CALARCO, ASSISTANT DIRECTOR 7 County Center Drive," Oroville, CA 96965 (530) 538-7601 Telephone (530) 538-2140 Facsimile { ADMINISTRATION * BUILDING * PLANNING CF -6R -ENV -01- ROOFING INSTALLATION CERTIFICATE (ROWSe(l k;r; :,r"i;tg 0!7;y) CF -6R -ENV -01 Envelope — Roofing Stile Address: Enforcement Agency: Permit Number: If more than one person has responsibility for Installation of the Items on this certificate, each person shall prepare and sign a certificate applicable to the portion of construction for which they are responsible; alternatively, the person with chief responsibility for construction shag prepare and sign this certificate for the entire construction. All applicable Mandatory Measures with check boxes require to be checked to ensure the mandatory measures have been met. ATTIC ROOF INSULATION AND/OR ATTIC RADIANT BARRIER Material: Brand Name: Material: Brand Name: Thickness Cinches): Thermal Resistance (R -Value): O §118(a): Insulation installed meets Standards for Insulating Material. ❑ §150(g): Mandatory Vapor banter installed in Climate Zone 16 Description of Roofing Products CRRC Product Manufacturer Brand/Model Product Roof Roof Product Initial Solar Aged Solar Thermal ID Number Information Type Area Slope Weight 2 Reflectance Reflectance4 Emittanoe 1. The CRRC Product ID Number can be obtained from the Cool Roof Rating Councils Rated Product Directory a ww. coolroofs. org/products✓searrl t. php 2. The weight In lbs per square feet of the morrng product being installed. 3. Check box if the Aged Reflectance is a calculated value using the equation below, footnote 4. 4. if the aged reflectance Is not available In the Cool Roof Rating Council's Rated Product Directory then use the Initial reflectance value from the directory and use the equation (0.2+0.7(pinitial — 0.2) to obtain a calculated aged value. QCHECK APPLICABLE BOX BELOW IF EXEMPT FROM THE ROOFING PRODUCT "COOL ROOF` REQUIREMENT.• ❑ The roof area covered by building integrated photovoltaic panels and building Integrated solar thermal panels are exempt from the above Cool Roof criteria. O Roof constructions that have thermal mass over the roof membrane with'a weight of at least 25 Ib/ft2 Is exempted from the above Cool Roof criteria. To apply Liquid Fleld Applied Coatings, the coating must be applied with a minimum dry mill thickness of 20 mils across the entire roof surface and meet minimum performance requirements listed in §11803 and Table '118-C. Select the applicable coating O Aluminum -Pigmented Asphalt Roof Coating O Cement -Based Roof Coating ❑Other QCRRC-1 Label Attached to CF -6R Note N no CRRC-1 label Is available, this compliance method cannot be 'used and another method is required to meet compliance). DECLARATION STATEMENT • I certify under penalty of perjury, under the laws of the State of California, the information provided on this form is true and correct. ■ I am eligible under Division 3 of the Business and Professions Code to accept responsibility for construction, or an authorized representative of the person responsible for construction (responsible person). • I certify that the installed features, materials, components, or manufactured devices identified on this certificate (the installation) conforms to all applicable codes and regulations, and the installation is consistent with the plans and specifications approved by the enforcement agency. ■ I reviewed a copy of the Certificate of Compliance (CF -1R) form approved by the enforcement agency that identifies the specific requirements for the installation. I certify that the requirements detailed on the CF -1 R that apply to the installation have been met. ■ 1 will ensure that a completed, signed copy of this Installation Certificate shall be posted, or made available with the building pennit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a signed copy of this Installation Certificate Is required to be included with the documentation the builder provides to the building owner at occupancy. Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Responsible Person's Name: Responsible Person's Signature: CSLB License: Date Signed: Position With Company (Title):