HomeMy WebLinkAboutB16-1767 039-380-010STORM WATER MITIGATION PLAN 15E5T MANAGEMENT PRAGTIGES THE FOLLOWIN6 ARE BEST MANAEEMENT PRACTICES AND MINIMUM STANDARDS FOR SEDIMENT AND EROSION CONTROL FOR PROJE01-5 DISTUR5IN6 LE55 THAN ONE ACRE. THESE PRACTICES SHALL BE IN PLACE THROUGHOUT THE PERIOD OF NOVEMBER 15 THROU6H APRIL I. BUILDING OFFICIAL SHALL GIVE NOTICE WHEN PRACTICES MAY BE REQUIRED THROU6HOUT THE YEAR BASED ON WEATHER CONDITIONS. 1. SCHEDULE WORK DURING THE DRY SEASON. 2. DIVERT STORM WATER FLOW AROUND ANY DISTURBED SOIL AREAS. 5. PRESERVE ALL EXISTING VEGETATION. 4. COVER ALL DISTURBED AREAS w/ TEMPORARY MULCH SUCH AS STRAW. 5. NO DRAIN INLETS OCCUR WITHIN i MILE OF PROJECT SITE. 6. NO ADJACENT PAVED PUBLIC, WAYS EXISTS WITHIN i MILE OF PROJECT SITE. SITE ENTRANCE AND EXIT STABILIZATION NOT APPLICABLE. i. GUTTING OR 6RADIN6 OF STEEP SLOPES 015%) SHALL BE AVOIDED WHENEVER POSSIBLE. WHERE OCCURS REDIRECT RUNOFF OR USE JUTE BLANKETS TO STABILIZE SOIL. 6. PROVIDE AN APPROVED AND LABELED AREA FOR CONCRETE WASHOUT. PLASTIC, SHEET LINED HAY BAILS MAY BE USED. WASHOUT SYSTEMS SHALL NOT BE PLACED IN PUBLIC, WAYS OR NEAR WATERWAYS OR DRAIN INLETS. Q. DO NOT GLEAN OR REFUEL VEHICLE AND EQUIPMENT ON SITE. VEHICLE MAINTENANCE SHALT. NOT BE PERFORMED ON CONSTRUCTION SITE. 10. STORE ALL CONSTRUCTION CHEMICALS, PAINT, FUEL, AND THE LIKE IN A COVERED AREA AWAY FROM STORM DRAIN SYSTEMS AND HARDSCAPE AREAS. 11. PORTABLE TOILETS WHERE PROVIDED SHALL BE KEPT ON CONSTRUCTION SITE PROPERTY AND AWAY MINIMUM 50' FROM ALL PUBLIC, WAYS AND STORM DRAIN SYSTEMS. DO NOT PLACE TOILETS OVER HARD HARDSCAPE AREAS. 12. ALL CONSTRUCTION TRASH SHALL BE REMOVED AND STORED IN COVERED TRASH RECEPTACLES. TRASH MUST NOT COME IN CONTACT WITH RAINFALL OR RUNOFF. 15. ADJACENT PAVED PUBLIC, WAYS SHALL REMAIN FREE OF DEBRIS AND SOILS REMOVED FROM CONSTRUCTION 51TE AT ALL TIMES. USE WATTLES TO MAINTAIN 51TE RUNOFF OVER CURB5, 6UTTER5 AND SIDEWALKS. USE DRAIN INLET PROTECTION DEVICES AND CATCH BASIN FILTERS AT ALL STORM WATER DRAIN INLETS WITHIN 50 YARDS OF SITE. 14. GENERAL CONTRACTOR SHALL MAINTAIN THE ABOVE SYSTEMS AND PRACTICES THROUGHOUT THE CONSTRUCTION PERIOD. 6C, SHALL EMPLOY A MAINTENANCE PROGRAM THOUGH OUT THE CONSTRUCTION PHASE OF THE PROJECT. 66. SHALL INFORM ALL EMPLOYED ON THE 51TE OF SUCH PRACTICES TO INSURE EFFECTIVENESS OF BEST MANAGEMENT PRACTICES. EXISTING WATER METER EX15TING GONG. - DRIVE SHALL SERVE AS A CONSTR. VEHICLE ENTRY/AGGESS EXIST. C.O.NO.* DRIVE 5ENERAL NOTE5 GOVERNING CODES AS FOLLOWS: 2013 CALIFORNIA BUILDING CODE(CBC), 2013 CRC, 2013 GEC, 2013 GPO, 2013 GMC, 2013 CFC, 2013 CALIFORNIA ENERGY CODE EFFICIENCY STANDARDS (ZONE 11). 2013 CALIFORNIA GREEN BUILDING STANDARDS CODE PLUMB 1 NG NOTES: I. THE AGGREGATE AREA OF PLUMBING VENTS SHALL BE 12.5-7 SQ. INCHES, MIN. 2. EXTERIOR H05E 5155 SHALL BE EQUIPPED WITH A NON -REMOVABLE BACKFLOW PREVENTION DEVICE. GPO SEG. 603.5.1 3. SHOWER AND TUB COMBINATIONS SHALL BE PROVIDED WITH INDIVIDUAL CONTROL VALVES OF THE PRESSURE BALANCE, THERMOSTATIC, OR COMBINATION PRESSURE 5ALANCE/THEM05TATIC MIXING VALVE TYPE. GPC, SEG. 406.q 4. GAS FIRED WATER HEATER TANK SHALL BE FASTENED TO THE ADJACENT FRAMING WITH 16 GA. METAL STRAP 4 2" LONG #12 WOODSREWS 8a� 4" ABOVE CONTROLS AND WITHIN 12" OF THE TOP OF THE TANK. • a-- 5. THE MAX. FLOW RATES SHALL APPLY TO THE PLUMBING FIXTURES AS FOLLOWS: o. WATER CLOSETS: 1.28 GALLONS PER FLUSH b. SHOWER HEADS: 2.0 GALLONS PER MINUTE. o. LAVATORY FAUCETS: 1.5 GALLONS PER MINUTE. d. KITCHEN FAUCETS: 1.5 GAL./MINUTE W/ 2.2 GAL./MINUTE TEMPORARY FLOW 6. THE NATURE OF WORK TO BE COMPLETED ON TH15 PROJECT WILL REQUIRE COMPLIANCE WITH CALIFORNIA SENATE BILL 401 FOR THE INSTALLATION OF WATER -CONSERVING PLUMBING FIXTURES. NOTE: ON AND AFTER JANUARY I, 2014, RESIDENTIAL BUILDINGS UNDERGOING PERMITTED ALTERATIONS, ADDITIONS OR IMPROVEMENTS SHALL REPLACE NON COMPLIANT PLUMBING FIXTURES WITH WATER-CONSERV i NG PLUMBING F I ZTURES. PLUMBING FIXTURE REPLACEMENT 15 REQUIRED PRIOR TO ISSUANCE OF A CERTIFICATE OF FINAL COMPLETION, CERTIFICATE OF OCCUPANCY OR FINAL PERMIT APPROVAL BY THE LOCAL BUILDING DEPARTMENT. SEE CIVIL CODE SECTION 1101.1 FOR THE DEFINITION OF NON COMPLIANT PLUMBING FIXTURE, TYPES OF RESIDENTIAL BUILDINGS AFFECTED AND OTHER IMPORTANT ENACTMENT DATES. MECHANICAL NOTES: I. DRYER DUCT SHALL BE A METAL MATERIAL A MIN. OF 4" DIAMETER AND SHALL HAVE A SMOOTH INTERIOR SURFACE. DUCT SHALL NOT BE FASTENED WITH SCREW TYPE FASTENERS WHICH MAY IMPEDE THE AIR FLOW OR CATCH LINT YET MUST BE FASTENED AND SEALED "SUBSTANTIALLY AIRTIGHT" AT EACH JOINT. (AN APPROVED FASTENING SYSTEM IS ALUMINUM DUCT TAPE) DRYER DUCT SHALL BE EQUIPPED WITH A BACK DRAFT DAMPER AND THE EXHAUST DUCT LENGTH SHALL BE 14 FEET MAXIMUM WITH WITH MAXIMUM TWO 010 DEGREE ELBOWS. INSTALLATION INSTRUCTIONS MUST BE APPROVED BY THE BUILDING OFFICIAL. (E) WATER By EXISTING _%I,. I EXISTING SHED I SHOP � rp `16 OF LEACH COVER ANY BARE - I I I I LINE SOIL AROUND SOIL 84' OF LEACH --,,\ 3:E II EXISTING GONG. REPLACEMENT MASTER BDRM. 1 WALK TO CONSTR. AREA SITE N1 BARLEY f :; SITE SHALL SERVE . NOTE: AREA OF p AS A CON5TR. TILE I I 1 ACCESS ti O I SOUSE 8 SQUARE FEET) TO • Poo* � EXISTING RESTROOM PRECAUTIONARY III r AT EXISTING SHOP COMPOST 50GK DURING RAIN 1 TO SERVE AS (STORMWATER • EVENT ALSO: COVER I SANITARY WA5TE RUN OFF BARRIER I I FACILITY IN LIEU TYPICAL. i -_ ` _ _> > OF PORT-A-POTTIE AROUND CONSTRUCTION .': _ l SITE w/ BARLEY STRAW. EXISTING 50' U j j l i LEACH FIELD. (E) WATER By DR. OLA ry L=4' Jry SHALL BE ,z, q.* ,20 TEMPERED _%I,. I TO A �J yn- L=4' �, 'Tim � �QJ I � rp `16 OF LEACH COVER ANY BARE - CENTERLINE OF VAULT I I I LINE SOIL AROUND SOIL rr'. 3:E II REPLACEMENT _� CONSTRUCTION O MASTER BDRM. Al I AREA SITE N1 BARLEY ' - NOTE: AREA OF STRAW, TYPICAL. 4 TILE I I DISTURBANCE MOO ti O I SOUSE 8 SQUARE FEET) TO • Poo* � BE COVERED III r CARPET 'c DURING RAIN 0 EVENT ALSO: COVER ALL BARE SOIL N O AROUND CONSTRUCTION l SITE w/ BARLEY STRAW. r U EX15TlNG EXISTING GONG.--_ TIGHT LINE DRIVE SHALL_--' Z SERVE ASA 1 LO LO =____-_====1Ii EXISTING CONSTR. VEHICLE 1 - (Y1 SEPTIC TANK ENTRY/AGGESS ALL EXISTING MD w 7 TR 5 WILL BE ABANDONED � SERVED LEACH FIELD W Z L 1-I r� O 43 O.H. PGCE �zo00 O� a�� Uco o POWER r C C) co .� �Ud Q z NOTE: NO DRAIN INLETS EX15TS ON MARIAN AVE. a r 0 n A Y �. PROPERTY INFORMATION OWNER5 NAME: w THOMAS FLEMINO PROPERTY ADDRE55: 1184 MARIAN AVE. APN. APN. 0541-580-010 FLOOD INFO. FLEMING X (UNSHADED) III _ 5 ITE PLA N ___ FLOOR PLAN STRUCTURAL _NOTE 1) SEE TYPICAL NOTE SHEET SN AND TYPICAL DETAIL SHEETS 501-SD3 FOR ADDITIONAL INFORMATION. 2) TYPICAL MINIMUM BEARING WALL FRAMING U.N.O.: EXTERIOR WALL: 2X4 DF STUD AT 16" O.G. INTERIOR WALLS: 2X4 DF STUD AT 16" O.G. 3) SEE DETAIL 5/SDI FOR TYPICAL STUD WALL ELEVATION AND TYPICAL WALL OPENING SCHEDULE. 4.) DO NOT REMOVE OR MODIFY SUPPORT MEMBERS OR HARDWARE FOR EXISTING FRAMING WITHOUT THE EXPRE55 WRITTEN CONSENT OF THE ENGINEER OF RECORD. 5) ANY DISCREPANCIES BETWEEN FRAMING SHOWN AND FIELD CONDITIONS SHALL BE IMMEDIATELY 5ROU6HT TO THE ENGINEER OF RECORD. 6) ALL EXPOSED FRAMING SHALL BE PRESSURE TREATED WITH TREATMENT PROCESS AND APPLICATION APPROPRIATE FOR EXPOSURE ACCORDING TO MFR'S WRITTEN GUIDELINES. 1) ALL STRUCTURAL MEMBERS SHALL BE FASTENED IN COMPLIANCE WITH 2013 GBG FASTENING SCHEDULE, TABLE 2304.9.1, UNLESS NOTED OTHERWISE. FLOOR PLAN 5TRUGTURAL NOTES: 1) SEE TYPICAL NOTE SHEET SN AND TYPICAL DETAIL SHEETS SDI-SD3 FOR ADDITIONAL INFORMATION. 2) TYPICAL MINIMUM 5EARIN6 WALL FRAMING U.N.O.: EXTERIOR WALL: 2X4 DF STUD AT 16" O.G. INTERIOR WALLS= 2X4 DF STUD AT 16" O.G. 3) SEE DETAIL 5/SDI FOR TYPICAL STUD WALL ELEVATION AND TYPICAL WALL OPENIN6 SCHEDULE. 4) DO NOT REMOVE OR MODIFY SUPPORT MEMBERS OR HARDWARE FOR EXISTING FRAMING WITHOUT THE EXPRE55 WRITTEN CONSENT OF THE ENGINEER OF RECORD. 5.) ANY DISCREPANCIES BETWEEN FRAMING SHOWN AND FIELD CONDITIONS SHALL BE IMMEDIATELY BROUGHT TO THE ENGINEER OF RECORD. 6) ALL EXPOSED FRAMING SHALL BE PRESSURE TREATED WITH TREATMENT PROCESS AND APPLICATION APPROPRIATE FOR EXPOSURE ACCORDING TO MFR'S WRITTEN GUIDELINES. 1) ALL STRUCTURAL MEMBERS SHALL BE FASTENED IN COMPLIANCE WITH 2013 GBG FASTENING SCHEDULE, TABLE 2304.9.1, UNLESS NOTED OTHERWISE. SPECIAL I N5PEGTI ON REGU I RED SPECIAL INSPECTION 15 REQUIRED IN ACCORDANCE WITH GBG CHAPTER 11 FOR THE EPDXY HOLDOWN ANCHOR BOLTS INSTALLED IN HARDENED CONCRETE. THE SPECIAL INSPECTOR MUST BE EMPLOYED BY THE OWNER AND APPROVED BY THE BUTTE COUNTY BUILDING DIVISION. PLEASE PROVIDE THE NAME OF THE SPECIAL INSPECTOR THAT WILL BE EMPLOYED TO PROVIDE THE SERVICE. SPECIAL INSPECTORS NOT ALREADY APPROVED BY THE BUTTE COUNTY BUILDING DIVISION MUST SUBMIT A STATEMENT OF QUALIFICATIONS AND VERIFICATION OF CURRENT ICG (OR EQUIVALENT) CERTIFICATION FOR THE PARTICULAR ITEM THEY WILL BE INSPECTING. ,TE SPECIAL INSPECTOR FOR TH15 PROJECT WILL BE BRAD FORSYTHE OF /APPLIED TESTING. CONTACT MR. FORSYTHE AT 3060 THORNTREE DRIVE #10, CHICO, GA 959'73 PHONE: (530) 691-6625 GODC AN^LT515 BUILDING TYPE: V -B OCCUPANCY: R-5 USE: RESIDENTIAL HOUSE 5QUARE FOOTAGE: 161Q 50. FT. SCOPE OP WORK TH15 PROJECT 15 A REBUILD/REMODEL OF AN EXISTING HOME. FA MINIMUM TITLE 24 REQUIREMENTS ' HEATING EFFICIENCY-. 92 AFUE v,- COOLING EFFICIENCY: 14 SEER 4 12 EER DUCT INSULATION: R-6 ✓ RADIANT BARRIER ROOF SHEATHING: NOT REQUIRED HERS VERIFICATION: DUCT LEAKAGE REQUIRED WATER HEATER EFFICIENCY: 0.996 PERMIT BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR CODE COMPLIANCE DATE IOJZCO COMBUSTION and VENTILATION AIR NOTE IF THE GAS WATER HEATER IS INSTALLED IN A CONFINED SPACE SUCH A5 A CABINET OR CLOSET (CONFINED SPACE 15 ONE HAYING A VOLUME OF LESS THAN 50 CUBIC FEET PER 1000 Btuh OF THE A66REOATE INPUT OF THE WATER HEATER WITHIN THAT SPACE), AIR MUST BE SUPPLIED THROUGH TWO PERMANENT OPENINGS OF EQUAL AREA. ONE 15 TO BE LOCATED WITHIN 12" ABOVE THE FLOOR AND THE OTHER IS TO BE LOCATED WITHIN 12" FROM THE GEILIN6. THE MINIMUM NET FREE AREA OF EACH OPENING MUST NOT BE LESS THAN ONE 5QUARE INCH PER 1000 Btuh OF THE TOTAL INPUT RATING OF THE GAS WATER HEATER IN THE ENCLOSURE (BUT NOT LESS THAN 100 SQUARE INCHES), IF EACH OPENING COMMUNICATES WITH OTHER UNCONFINED AREAS INSIDE THE BUILDING. TOTAL Btu's / 1000 X 50 = MIN. CU. FT. OF ROOM SIZE iUA41 . W.H. DOOR: VENT TOP d BOT. w/ VENTS HAVING MIN. 100 50. w��� FvN c. JOy9�t�y IN. EA. OF NET FREE AREA FOR COMBUSTION AIR INTAKE. VL SEE "COMBUSTION AND VENTILATION AIR NOTE" ABOVE. w 8.3 3 OZ ?m 41'-O" 5:_0:1 Q %J * "..012 tp 9'-6" �'-6" 14'-4" sp�T CIVi1. 4PROVIDE FOR OFC MIN. TYP. SHEARWALL 46" 5Q. LANDING 5Di ELEVATION I GAS WATER HEATER SEE PLUMBING NOTE #4 IN THE GENERAL NOTES THIS PAGE. By DR. OLA ry L=4' Jry SHALL BE ,z, q.* ,20 TEMPERED a ALL DOORS O.S. ,TYPIC TO A �J yn- L=4' �, 'Tim � �QJ l u p 0 1 THESE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE ONLY WITH THE ATTACHED SUCTURAL CALCULATIONS � rp ULTIL SHOWER tt 14* L=4' 505OPH 50505H CENTERLINE OF VAULT 3068 6' CEILING rr'. 3:E L=JR4�>0O0 KITCHEN - d O E 6' GEILIN6 n to ° I DW L - +42" EATING BAR FLAT GLC. - - - - - - - -- GEILIN6 BREAK By A"- H. --------------- It SHWR. - Hv. HD. ULTIL SHOWER tt 14* L=4' CENTERLINE OF VAULT IL,114CRVIOE 6' CEILING rr'. 3:E W. MASTER BDRM. Al I _ u') ' - m n i CEILING O 2866 Q TILE V1 266 V CEILING ti O ��ryn� `=LCL • Poo* � TILE 0) r CARPET 'c u� X 0 N O U ^, W L=JR4�>0O0 KITCHEN - d O E 6' GEILIN6 n to ° I DW L - +42" EATING BAR FLAT GLC. - - - - - - - -- GEILIN6 BREAK m REF. 2468 WALK-IN p CLOSET O r- T6-LOn ATTIC 1 w ACCESS GREAT ROOM VAULTED GEILIN6 -_-- GEILINOBREAK - - - - - -- � FLAT GLC. 1 501 TYP. HD ® CORNER L=4' 4* J �OJ'Z Q - y 305OSH 50505H 4 �� POCKET BM. L=4' INTO WALL BUTTE COUNTY OCT 19 2016 I6'-6" DEVELOPMENT SERVWES 1/7 DIcP � o�m 30505H WINDOW MEETS p EMERGENCY AGGESS, o LIGHT AND VENTI- LATION REQUIREMENTS. HALLr BEDROOM Ll o p 6' GEILIN6 = 6' CEILING CARPET 4'-0"4'-0" V-4" II' -8" . ......... I --------------------- 4 54-61 L: LINEN � tY 26 HALL BATH 2 Wwp 6 8' CEILING m 2466 TLE CEILIN& TUB/ W x F.F. O HWR. - OM LINEN O 66 SHWR. Op HD. 0. LL wu0i BEDROOM J! N b' 01 CARPET CARPET 50505H ' PORCH GONG. FLR. p"' L -NEW GONG. Q PORCH SEE p,-I1x , FOUND. PLAN Av L=4' AREAS N LIVING AREA: 16161 50. FT. (400 ADDITION) COVERED PORCH: 66 SO. FT. 1,p.=,, -o. FLOOR PLA N Revisions By A"- It CENTERLINE OF VAULT rr'. -'r-REMOVE EXISTING MASONRY FIREPLACE 0) i u') O V1 m REF. 2468 WALK-IN p CLOSET O r- T6-LOn ATTIC 1 w ACCESS GREAT ROOM VAULTED GEILIN6 -_-- GEILINOBREAK - - - - - -- � FLAT GLC. 1 501 TYP. HD ® CORNER L=4' 4* J �OJ'Z Q - y 305OSH 50505H 4 �� POCKET BM. L=4' INTO WALL BUTTE COUNTY OCT 19 2016 I6'-6" DEVELOPMENT SERVWES 1/7 DIcP � o�m 30505H WINDOW MEETS p EMERGENCY AGGESS, o LIGHT AND VENTI- LATION REQUIREMENTS. HALLr BEDROOM Ll o p 6' GEILIN6 = 6' CEILING CARPET 4'-0"4'-0" V-4" II' -8" . ......... I --------------------- 4 54-61 L: LINEN � tY 26 HALL BATH 2 Wwp 6 8' CEILING m 2466 TLE CEILIN& TUB/ W x F.F. O HWR. - OM LINEN O 66 SHWR. Op HD. 0. LL wu0i BEDROOM J! N b' 01 CARPET CARPET 50505H ' PORCH GONG. FLR. p"' L -NEW GONG. Q PORCH SEE p,-I1x , FOUND. PLAN Av L=4' AREAS N LIVING AREA: 16161 50. FT. (400 ADDITION) COVERED PORCH: 66 SO. FT. 1,p.=,, -o. FLOOR PLA N Revisions By r 0) 0) u') O V1 � O ��ryn� `=LCL • Poo* � 0) 'c 0 N O U ^, W Z LO LO Q H MD w W W Z 1-I r� O I �zo00 O� a�� Uco 0- C C) co .� �Ud Q O �, Mw W W w W FLEMING REMODEL Date 10-10-16 Scale SHOWN Drawn M.A. Sheet Of � Sheets ROOF PLAN 5TRUCTURAL NOTES: NON-COMPLIANT PLUMBING 1) SEE TYPICAL NOTE SHEET 5N AND TYPICAL DETAIL 12) ROOF TRUSS LAYOUT SHALL BE REVIEWED BY ENGINEER SHEETS 501-503 FOR ADDITIONAL INFORMATION. A5 TRUSS DE51&N5 BECOME AVAILABLE FROM TRUSS (N) 24" X IS" MANUFACTURER. CONTRACTOR SHALL OBTAIN 516NE0 2) TYPICAL ROOF SHEATHING (UNO): 1/2" THICK, APA, TRUSS REVIEW LETTER FROM THE ENGINEER OF RECORD TECO, OR PITTSBURGH RATED 5HEATHIN(5, SPAN AND BUILDING DEPARTMENT APPROVAL PRIOR TO RATING 32/16, EXPOSURE I STRUCTURAL PANELS, CONSTRUCTION. APPLIED WITH LONG DIMENSION ACROSS SUPPORTS AND ADJACENT PANELS STAGGERED WITH WENDS 15) CONTRACTOR TO VERIFY THE LOCATION AND LOADING OFFSET 4'. EDGE NAIL WITH ad COMMON OR OF ALL TRUSS TO TRUSS MECHANICAL CONNECTIONS. EQUIVALENT (0.131" DIA X 2 1/2") AT 6" O.G. AT IMMEDIATELY NOTIFY TRU55 COMPANY OF ANY ALL PANEL EDGES, BOUNDARIES, GABLE ENDS, DISCREPANCIES. BLOCKING AND WHERE INDICATED ON PLAN. FIELD NAiL AT 12" O.G. PROVIDE 1/8" GAP AT ALL PANEL 14.) PROVIDE METAL HANGERS PER 5/5D1 A5 REQUIRED, ED6E5 U.N.O. BY PANEL MANUFACTURER. AT ALL LOW UNLESS NOTED OTHERWISE. SLOPE ROOFS PROVIDE (1) PANEL CLIP MIN. BETWEEN SUPPORTS AT ABUTTING PANEL EDGES. 15) ALL STRUCTURAL MEMBERS SHALL BE FASTENED IN Fn1 COMPLIANCE WITH 2013 GBG FA5TENIN6 SCHEDULE, 3.) SEE NOTE SECTION 8-5N FOR ROOF TRUSSES BY TABLE 2304.9.1, UNLE55 NOTED OTHERWI5E. OTHERS. Exceed 1.6 4) TYPICAL HEADER BELOW SHALL BE: ARCHITECTURAL ROOF PLAN NOTES: 4X8 DF -L #2 UNO. I. ROOF PITCH SHALL BE: A5 SHOWN 5) PROVIDE 4X POST MIN. AT ALL BEAM AND 61RDER 2. ROOF O.H. SHALL BE A5 SHOWN. 3. ROOF COVERING SHALL BE: COMPOSITION SHINGLE ROOF iRU55 BEARING POINTS AND CONTINUE IN WALL TO o/ 5HEATHIN6 PER ROOF PLAN STRUCTURAL NOTES THI5 PACE. FOUNDATION. 4. PROVIDE NET FREE VENTILATION TO THE ENTIRE ATTIC, 6.) USE 2X4 DF #2 MIN. RAFTERS AT 24" O.G. AT LOW AREA OF 1/300 (1 50. FT. VENTILATION PER 500 50. FT. OF ATTIC AREA) PROVIDED THE FOLLOWING CONDITION 15 MET: ROOF PORTIONS, MAXIMUM SPAN = 4'-5". AT LEAST 40% AND NOT MORE THAT 50% OF THE REQUIRED -IJ PROVIDE P05. ATTACHMENT OF ALL POST TO BEAM, VENTILATING AREA 15 PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE ATTIC, SPACE. UPPER BEAM TO BEAM, BEAM TO POST, AND P05T TO P05T CONN'S WITH (2) 5T22 STRAPS MIN. AND A35 CLIPS, VENTILATORS SHALL BE LOCATED NO MORE THAN 3 FT. BELOW U.N.D. PER PLAN AND DETAILS. THE RIDGE OR HIGHEST POINT OF THE SPACE, MEASURED VERTICALLY, WITH THE BALANCE OF THE REQUIRED VENTILATION 8J DO NOT REMOVE OR MODIFY SUPPORT MEMBERS OR PROVIDED BY EAVE OR CORNICE VENTS. WHERE THE LOCATION HARDWARE FOR EXISTING FRAMING WITHOUT THE OF WALL OR ROOF FRAMING MEMBERS CONFLICTS WITH THE EXPRESS WRITTEN CONSENT OF THE ENGINEER OF INSTALLATION OF UPPER VENTILATORS, INSTALLATION MORE THE R06E OR HICHE5T POINT OF THE SPACE RECORD, THAT 3 FT. BELOW SHALL BE PERMITTED. 9.} ANY DISCREPANCIES BETWEEN FRAMING 5HOWN AND FIELD CONDITIONS SHALL BE IMMEDIATELY BROUGHT ATTIC, OVER LIVING SPACE VENTILATION TO THE ENGINEER OF RECORD. ATTIC AREA ABOVE LiVIN& SPACE: 16111 50. FT. Within units: 16111/300=5.311 50. FT. OF NFVA REQUIRED 10.) VERIFY ALL ELEVATIONS, STEPS, DIMENSIONS, RAKE HIPS AND VALLEYS WITH ARCHITECT. 5.3x/2=2.611 50. FT. REQUIRED BOTH 1­115HAND LOW (2169X144=388 SO. IN. REQUIRED BOTH HIGH AND LOW) BREAKS, SLOPES, Maximum 1.5 gallons per 11.) ALL EXPOSED FRAMING SHALL BE PRE55URE INSTALL (18) 22"x3.5" SAVE VENTS w/ A NFVA OF 22 SQ. IN. EA. TREATED WITH TREATMENT PROGES5 AND APPLICATION 18x22=3116 50. IN. PROVIDED. APPROPRIATE FOR EXPOSURE ACCORDING TO MFR'S INSTALL (4) 14"x24" GABLE END VENTS w/ A NFVA OF 9'7.6 IN. EA WRITTEN GUIDELINES. 4x9'7.6=390 SQ. IN. PROVIDED W' O.H. ® TYPICAL HEADERS: /EAVES, TYP. 4x16 D.F. #2 _ 4x10 D.F. #1 BM. r 18" O.H. TYPICAL 0 CABLE ENI <� I I I 3 I I SD3 I I TYP. GABLE (� END �(4)A55 CLIPS DRAG TRUSS -to -DOUBLE TOP PLATE 1 1 I I I I 6:12 I I DRAG 61RDER (4)A55 CLIPS DRAG TRUSS -to -DOUBLE TOP PLATE DRAC- (4)A35 CLIPS DRAG TRUSS -to -DOUBLE TOP PLATE 1/411=11-011 /411=11-O11 x•12 1500# TRUSS 1500# 1. If the existing plumbing fixture water usage/flow rate is equal to or lowe than the figure shown, it is not required to be upgraded. 1 (4)A35 CLIPS DRAG I I TRUSS -to -DOUBLE I I TOP PLATE I I I I 1 I I\ i N OI OI --rr nI 1 l� I 1-T-1 �1 22 x 50"\ 1 ° ATTIC G L__�E55 A, t tj SEE DET. 1/3 FOR F.A.U. MOUNTING.- trT111 SD3 s � NOTE: PROVIDE SERVICE LI&94T w/ SWITCH a9 ACCESS HOLE 8 IIOV I SERVICE OUTLET ® FAU. PROVIDE 24" WIDE CATWALK FROM AGCE55 N HOLE TO 50" SO. x 30" H16H CLEAR MAINTENANCE PLATFORM �0 n PER 4/SD3 M5TA36 STRAP DT PLATE -to - DRAG TRUSS N SD3 ff � 4xi0 D.F.-#1 B_M__ L__ K I TYP. SV!l �� cc � I I I { I NON-COMPLIANT PLUMBING WATER-GON5ERVIN6 PLUMBING FIXTURE (Fixture Complying with current Code Applicable to New Construction) 11a TYPICAL FLOOR 5HEATHINC (UNO): 3/4" THICK, APA FIXTURE 1 RATED 5HEATHIN6 OR RATED STURD-I-FLOOR, SPAN (N) 24" X IS" MAXIMUM WATER USACE/FLOW RATE 2013 GPO Ch. 4 2013 GALGreen 2013 GPO Ch. 4 2013 GALCreen 2013 GPO Ch. 4 2013 CALGreen FIXTURE TYPE WATER U5A6E/ �' SD FLOW RATE Div. 4.3 Div. 4.3 Div. 5.3 51N6LE-FAMILY MULTI -FAMILY COMMERCIAL 5LABS)-SEE SOILS REPORT IF APPLICABLE. G- 4" FREE DRAINING MATERIAL -SEE SOILS REPORT FL___jL-J L -J ALL FLOOR RESIDENTIAL RE5IDENTIAL Fn1 SUBCONTRACTOR. E- CONTRACTOR TO PROVIDE CONTROL JOINTS AT 10'-O" O.G. EA. WAY MAX. Single flush toilets: 128 gal lons/f lush Water Closets Exceed 1.6 Dual flush toilets: 1.25 gallons/flush effective flush volume (the composite,overoge flush volume (the composite, average flush volume of two reduced (Toilets) gallons/flush flushes and one full flush) INTERIOR WALLS: 2X4 DF STUD AT 16" O.G. Exceed 1.0 gal. 0.5 gallons/flush Urinals per flush W RECORD. 2.0 gallons per minute 0 80 psi. Also certified to the performance criterla of U.S. 13J ANY DISCREPANCIES BETWEEN FRAMING SHOWN AND 2X6 DF2 AT ib��O.G. (MAX SPAN = 7 -11) FIELD CONDITIONS SHALL BE IMMEDIATELY BROUGHT EPA WaterSense Spealf icotlon for Shower heads TO THE ENGINEER OF RECORD. WALLS RUN PARALLEL TO JOIST. (A hand-held shower is considered a showerheod) Shower heads Exceed 2.5 gallons minute For multiple shower heads serving one shower, the combined flow rate of ail ail shower heads and/or other shower outlets controlled by a single valve shall not ARCHITECT. per exceed 2.0 gallons per minute as 80 psi, or the shower shall be designed to allow IF FLOOR BUILD-UP WILL EXCEED 15 PSF. TREATED WITH TREATMENT PROCESS AND APPLICATION only one shower outlet to be in operation at a time. APPROPRIATE FOR EXPOSURE ACCORDING TO MFR'S Maximum 1.5 gallons Within units: 0.5 gallons per minute 1. &RADE IMMEDIATELY ADJACENT TO THE UNLESS NOTED OTHERWISE. per minute a 60 psi; Maximum 1.5 gallons per a 60 psi Faucets- Exceed 2.2 minimum O.8 gallons per minute a 20 psi minute ® 60 psi; min. 0.8 gallons per TABLE 2304.9.1, UNLESS NOTED OTHERWI5E. Lavatory ollons per minute minute 0 20 psi Four,ets PROVIDE FOR MIN. In common and publtc use PERMIT # BUTTE COUNTY DEVELOPMENT SERVICES 45" So. LANDING 1 .rYP SS ® THIS DOOR 502 �� areas: 0.5 gallons per REVIEWED FOR CODE COMPLIANCE 6 minute a® 60 psi lb gallons per minute lb gallons per minute I.8 gallons per minute a 60 P.S.I. May a 60 P.S.I. May a 60 psi temporally increase temporally increase up to 2.2 gallons per up to 2.2 gallons per minute a 60 psi, and minute a 60 psi, and Faucets- Exceed 2.2 must default to Kitchen gallons maximum 1.& gallon per must default to maximum 1.8 gallon per Faucets per minute minute a 60 p.s.i. Where faucets minute ® 60 p.s.i. Where faucets meeting the above meeting the above are unavailable, are unavailable, aerators or other aerators or other means may be used means may be used to achieve reduction. to achieve reduction. 1. If the existing plumbing fixture water usage/flow rate is equal to or lowe than the figure shown, it is not required to be upgraded. 1 (4)A35 CLIPS DRAG I I TRUSS -to -DOUBLE I I TOP PLATE I I I I 1 I I\ i N OI OI --rr nI 1 l� I 1-T-1 �1 22 x 50"\ 1 ° ATTIC G L__�E55 A, t tj SEE DET. 1/3 FOR F.A.U. MOUNTING.- trT111 SD3 s � NOTE: PROVIDE SERVICE LI&94T w/ SWITCH a9 ACCESS HOLE 8 IIOV I SERVICE OUTLET ® FAU. PROVIDE 24" WIDE CATWALK FROM AGCE55 N HOLE TO 50" SO. x 30" H16H CLEAR MAINTENANCE PLATFORM �0 n PER 4/SD3 M5TA36 STRAP DT PLATE -to - DRAG TRUSS N SD3 ff � 4xi0 D.F.-#1 B_M__ L__ K I TYP. SV!l �� cc � I I I { I \l i i I I I la SEE TYPICAL NOTE SHEET 5N AND TYPICAL DETAIL 11a TYPICAL FLOOR 5HEATHINC (UNO): 3/4" THICK, APA SHEETS SDI-SD3 FOR ADDITIONAL INFORMATION. (4)A35 CLIPS DRAG TRU5S-to- DOUBLE TOP PLATE ROOF PLAN FOUNDATION PLAN 5TRUCTURAL NOTE5: la SEE TYPICAL NOTE SHEET 5N AND TYPICAL DETAIL 11a TYPICAL FLOOR 5HEATHINC (UNO): 3/4" THICK, APA SHEETS SDI-SD3 FOR ADDITIONAL INFORMATION. RATED 5HEATHIN6 OR RATED STURD-I-FLOOR, SPAN (N) 24" X IS" RATING 48/24 (24 FOR STURO-I-FLOOR), EXPOSURE ACCESS TO NEW 2) PROVIDE ANCHOR BOLT 51ZE AND 5PAGIN6 PER 3 U.F. AREA. VERIFY 5TA66ERED WITH 4' EN05 OFFSET 4'. GLUE PANELS TO ALL FRAMING, EDGE NAiL WITH IOd COMMON RING �' SD LOCATION A- 4" CONCRETE SLAB WITH #3 AT 15" O.G. SECURELY LOCATED AT MID -DEPTH OF SLAB. (0 I PROVIDE I/8" GAPS AT ALL PANEL EDGES U.N.O. BY A5TM E 1643 (DELETE AT EXTERIOR PANEL MANUFACTURER. 5LABS)-SEE SOILS REPORT IF APPLICABLE. G- 4" FREE DRAINING MATERIAL -SEE SOILS REPORT FL___jL-J L -J ALL FLOOR IF APPLICABLE. D- PROPERLY PREPARED 5U156RADE-5EE 501LS I Fn1 FOUNDATION PLAN 5TRUCTURAL NOTE5: la SEE TYPICAL NOTE SHEET 5N AND TYPICAL DETAIL 11a TYPICAL FLOOR 5HEATHINC (UNO): 3/4" THICK, APA SHEETS SDI-SD3 FOR ADDITIONAL INFORMATION. RATED 5HEATHIN6 OR RATED STURD-I-FLOOR, SPAN H RATING 48/24 (24 FOR STURO-I-FLOOR), EXPOSURE I STRUCTURAL PANELS, APPLIED WITH LONG 2) PROVIDE ANCHOR BOLT 51ZE AND 5PAGIN6 PER DIMENSION ACROSS SUPPORTS AND ADJACENT PANELS SHEAR WALL SCHEDULE AND TYPICAL DETAILS. 5TA66ERED WITH 4' EN05 OFFSET 4'. GLUE PANELS TO ALL FRAMING, EDGE NAiL WITH IOd COMMON RING 3.) RECOMMENDED SLAB SECTION: SHANK NAILS OR EQUIV. (0.148" DIA X 3") AT 6" O.G. AT ALL PANEL ED6E5, BOUNDARIES, BLOCKING AND A- 4" CONCRETE SLAB WITH #3 AT 15" O.G. SECURELY LOCATED AT MID -DEPTH OF SLAB. WHERE INDICATED ON PLAN. FIELD NAIL AT 10" O.G. B- WATERPROOF MEMBRANE IN COMPLIANCE WITH PROVIDE I/8" GAPS AT ALL PANEL EDGES U.N.O. BY A5TM E 1643 (DELETE AT EXTERIOR PANEL MANUFACTURER. 5LABS)-SEE SOILS REPORT IF APPLICABLE. G- 4" FREE DRAINING MATERIAL -SEE SOILS REPORT 10)�� NO,SPRINKLER, NDC AL NAGOCHxA C�) ALL FLOOR IF APPLICABLE. D- PROPERLY PREPARED 5U156RADE-5EE 501LS AND WALL PENETRATIONS WITH FRAMING REPORT IF APPLICABLE. SUBCONTRACTOR. E- CONTRACTOR TO PROVIDE CONTROL JOINTS AT 10'-O" O.G. EA. WAY MAX. 11J PROVIDE P05. ATTACHMENT FOR ALL BEAM TO P05T, z0� O � 4CO BEAM TO BEAM, POST TO BEAM, AND P05T TO P05T 4.) TYPICAL MINIMUM BEARING WALL FRAMING U.N.O.: CONN'S WITH (2) 5T22 STRAPS MIN. AND A35 CLIPS EXTERIOR WALL: 2X4 OF STUD AT 16" O.G. U.N.O. PER PLAN AND DETAILS. INTERIOR WALLS: 2X4 DF STUD AT 16" O.G. 12) DO NOT REMOVE OR MODIFY SUPPORT MEMBERS OR 5) SEE DETAIL 5/501 FOR TYPICAL STUD WALL HARDWARE FOR EXI5TIN& FRAMING WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ENGINEER OF ELEVATION AND TYPICAL WALL OPENING SCHEDULE. W RECORD. 6) TYPICAL FLOOR JOIST AT GROUND LEVEL SHALL BE: 13J ANY DISCREPANCIES BETWEEN FRAMING SHOWN AND 2X6 DF2 AT ib��O.G. (MAX SPAN = 7 -11) FIELD CONDITIONS SHALL BE IMMEDIATELY BROUGHT 7a PROVIDE DOUBLE JOIST UNDER ALL WALLS WHERE TO THE ENGINEER OF RECORD. WALLS RUN PARALLEL TO JOIST. 14) VERIFY ALL ELEVATIONS, 5TEP5, DIMENSIONS, WALL eQ FLOOR FRAMING HAS BEEN DESIGNED FOR A MAXIMUM SIZES AND LOCATIONS, AND FLOOR ELEVATIONS WITH DEAD LOAD OF 15 P5F (INCLUDING FRAMING). CONTACT ARCHITECT. SUMMIT STRUCTURAL DESIGN, PRIOR TO CONSTRUCTION, 15) ALL EXPOSED FRAMING SHALL BE PRESSURE IF FLOOR BUILD-UP WILL EXCEED 15 PSF. TREATED WITH TREATMENT PROCESS AND APPLICATION APPROPRIATE FOR EXPOSURE ACCORDING TO MFR'S WRITTEN GUIDELINES. NOTE: I(o) PROVIDE METAL HANGERS PER 8/90I A5 REQUIRED, 1. &RADE IMMEDIATELY ADJACENT TO THE UNLESS NOTED OTHERWISE. FOUNDATION SHALL SLOPE AWAY FROM BUILDING AT A SLOPE A MINIMUM OF 2% Ila ALL 5TRCTURAL MEMBERS SHALL BE FASTENED IN PER SECTION R401.3. COMPLIANCE WITH 2013 GBG FASTENING SCHEDULE, TABLE 2304.9.1, UNLESS NOTED OTHERWI5E. 41'-D° 5111 PROVIDE FOR MIN. PERMIT # BUTTE COUNTY DEVELOPMENT SERVICES 45" So. LANDING 1 .rYP SS ® THIS DOOR 502 �� ,�4 REVIEWED FOR CODE COMPLIANCE 6 ��(/ O DATE _�O "��' �� BY' Sr r 1 NFVA EA. LOCATE VENTS PER FOUNDATION PLAN. 22 X'71= 1556 50. IN. r-, L -J L -J L L L -J L -J I---Ji y, I2 -2 m sY VERIFY 12"xi2" CONTINUOS FOOTING w/ #4 TOP b BOTTOM CONTACT E.O.R. w/ 0150REPANGIE5 W� L_J L_J L__Jj IL - t N° LU �0 EXI5TIN6 GONG. ° 5'-4" MAX. FIREPLACE FOUNDATION jg TYP. TOREMAI r-, Nr-, r-, r-, r-� r_, r L -J L -J L -J IL -J L -J L -J L -J L J IL --_j I- JI (N)4x6 D.F. #2 GIRDER, TYP. 2 7 TYP. 51�, j �Cb INEW 4" THICK GONG. (N) 15" 511• x 12" THICK PORCH SLAB w/ #4 24" O.G. E.W., BROOM PRECAST GONG. PIER, TYP. (F3) TYP- HD � FIN. SLOPE TO DRAIN ® EXIST. SD2 oH.5 16" 50. x �J m 6 TYP. SD2 THICK w/ 24" 50. x 12" THICK T # I SD2 (3) #4 E.W. �� C w/ (3) 4 EA.WAY l d- tq � Q 4J m 4 �` Date 10-10-I160 Q�OrESv'UnA Scale 5HOY `�N c� c ,�4�Vy C. JChA, t 62 Drewn _7 C, sQ ESQ �cJ so �R` THESE PLANS HAVE BEEN M A. 4 OH. RSz �A $ 2 REVIEWED FOR COMPLIANCE sheet 'nO �j�� 04 SD2 ONLY WiTH THE ATTACHED 101-0" 5'-g" i3'-8" * E * STRUCTURAL CALCULATIONS w i 1 i►11 sT CiVIL gTFGFCA',.0� �bltD It b Of 3 Sheets Revisions I By H UNDER FLOOR VENTILATION H PROVIDE 1 50. FT. OF UNDER- FLOOR (U -F) VENTILATION PER SS 150 50. FT. OF U.F. AREA. ONE VENTILATION OPNC. SHALL BE WITHIN 3 FT. OF EA. CORNER OF r-, rTHElBUILDING. r- r --I r--1 8 TYP. D2 L -J L -J L -J L -J L VENTILATION CALCULATION L -J 16111 50. FTY150=10.7711 50. FT. REQ'D. (10.19X144=1554 50. IN. REQ'D) zV F-1 INSTALL (22) 14" X 6" FOUNDATION C�) VENTS PROVIDING 71 SQ. IN. OF r 1 NFVA EA. LOCATE VENTS PER FOUNDATION PLAN. 22 X'71= 1556 50. IN. r-, L -J L -J L L L -J L -J I---Ji y, I2 -2 m sY VERIFY 12"xi2" CONTINUOS FOOTING w/ #4 TOP b BOTTOM CONTACT E.O.R. w/ 0150REPANGIE5 W� L_J L_J L__Jj IL - t N° LU �0 EXI5TIN6 GONG. ° 5'-4" MAX. FIREPLACE FOUNDATION jg TYP. TOREMAI r-, Nr-, r-, r-, r-� r_, r L -J L -J L -J IL -J L -J L -J L -J L J IL --_j I- JI (N)4x6 D.F. #2 GIRDER, TYP. 2 7 TYP. 51�, j �Cb INEW 4" THICK GONG. (N) 15" 511• x 12" THICK PORCH SLAB w/ #4 24" O.G. E.W., BROOM PRECAST GONG. PIER, TYP. (F3) TYP- HD � FIN. SLOPE TO DRAIN ® EXIST. SD2 oH.5 16" 50. x �J m 6 TYP. SD2 THICK w/ 24" 50. x 12" THICK T # I SD2 (3) #4 E.W. �� C w/ (3) 4 EA.WAY l d- tq � Q 4J m 4 �` Date 10-10-I160 Q�OrESv'UnA Scale 5HOY `�N c� c ,�4�Vy C. JChA, t 62 Drewn _7 C, sQ ESQ �cJ so �R` THESE PLANS HAVE BEEN M A. 4 OH. RSz �A $ 2 REVIEWED FOR COMPLIANCE sheet 'nO �j�� 04 SD2 ONLY WiTH THE ATTACHED 101-0" 5'-g" i3'-8" * E * STRUCTURAL CALCULATIONS w i 1 i►11 sT CiVIL gTFGFCA',.0� �bltD It b Of 3 Sheets Revisions I By H H NW W r� 1D zV F-1 C�) 4 t~ 1 o� z0� O � 4CO O o co w W � w W 1/4"=1'-O" FOUNPAT I ON PLAN 3/8" DI THREAt ROD (6 PER Fr A. SINGLE POLE SWITCH 14"x24" CABLE END GLC. MTD. FIXT. D )ED 14"x24" &ABLE END VENTS, TYPICAL. THREE WAY SWITCH VENTS, TYPICAL. 2x6 BARGE, LIGHTING TRANSFORMER D w) TYPICAL �•� COMPOSITION SHINGLE ROOF PANEL BOARD F.A.U. Ira L�r MINI RECESSED GL6. FIXT. FASCIA CUTTER TYP. ELEC. DISCONNECT T TIMER SWITCH I AT ALL EAVES IrHl GEMENT BD. SIDING w/ GEMENT BD. IX4 BATTENS OVER ® 16" O.G. INSTALL UNDERLAYMENT( 120v DUPLEX REGEPT. --2X4 ® TRIM ® CORNERS, 4" ®DRS. AND WDWS. PROVIDE OPTION FOR B BELL MEETING SIDING MFR. SPECS. 220 VOLT OUTLET 00 6" TRIM, VERIFY w/ FEE* cion 110 V. SMOKE DETECTOR AND SEG. R705.2 0) DESIGNER GM IIOv CARBON MONOXIDE EAST ELEVATION NEST ELEVATION NORTH ELEVATION 3/8" DI THREAt ROD (6 PER Fr A. SINGLE POLE SWITCH T GLC. MTD. FIXT. D )ED �3 THREE WAY SWITCH -�- RODS LIGHTING TRANSFORMER D w) HIGH EFFICACY RECESSED 01-6. FIXT. �•� PANEL BOARD F.A.U. DIMMER/5-WAY SWITCH I I/8" x I I/8" ANGLE w/ (2) 1/4" x 2" LONG LA6 BOLTS INTO TOP CHORD OF TRUSS, TYPICAL. SEISMIC RESTRAINTS (4) DIRECTIONS 1-5/8" x 1-5/8" 12 &A. UNISTRUT Fi F.A.U. MOUNTING 5/411 i t -Oil ELECTRICAL PLAN NOTES: I. PROVIDE AN ADDITIONAL 20 AMP BRANCH CIRCUIT WHICH WILL SERVE THE LAUNDRY ROOM, PANTRY, DINING ROOM, BATH ROOMS AND SIMILAR AREAS. PROVIDE AT LEAST TWO 20 -AMP SMALL APPLIANCE BRANCH CIRCUITS TO BE SUPPLIED TO THE KITCHEN COUNTER TOP RECEPTACLES. THESE CIRCUITS SHALL SERVE NO OTHER OUTLETS. 2. PROVIDE 4 -WIRE RECEPTACLES FOR ALL DRYER AS PER GEC, 250-60. 5. SMOKE ALARMS AND CARBON MONOXIDE DETECTION DEVICES SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING AND SHALL BE EQUIPPED WITH A BATTERY BACKUP. 4. ALL 15 d 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN BEDROOMS, FAMILY ROOMS, DINING ROOMS LIVING ROOMS, LIBRARIES, DENS, RECREATION ROOMS, HALLWAYS, CLOSETS OR SIMILAR ROOMS, SHALL BE INSTALLED WITH A COMBINATION ARG -FAULT CIRCUIT INTERRUPTER. 5. FIXTURES, LAMP HOLDERS AND RECEPTACLE OUTLETS SHALL BE SECURELY SUPPORTED. A FIXTURE THAT WEIOH5 MORE THAN 6 LBS. OR EXCEEDS 16" IN ANY DIMENSION SHALL NOT BE SUPPORTED BY THE SCREW SHELL OF A LAMP HOLDER PER 5EC.410.15 (o). OUTLET BOXES SHALL NOT BE USED AS THE SOLE SUPPORT FOR GEILIN6 FANS PER 2010 SEG. 514.21 (add) 6 ALL 125 VOLT, SINGLE PHASE 15 AND 20 AMP RECEPTACLES SHALL BE LISTED TAMPER RESISTANT. 7. PROVIDE STUB FOR LANDSCAPE 1_16HTIN6 AND SWITCH ® FRONT DOOR. PROVIDE d INSTALL IRRIGATION TIMER LOCATE PER OWNER DIRECTION. 8. BATHROOMS AND LAUNDRY ROOM AND ALL CLOSET L16HT5 SHALL MANUAL MOTION SENSOR. (MMS) q. VERIFY LOCATION OF MAIN PANEL AND SUB PANEL. 10 . RECESSED FIXTURES INSTALLED IN INSULATED CEILINGS ARE IGAT AND CERTIFIED ASTM E2b5 OR EQUIVALENT. INSTALLATION 15 AIRTIGHT (CAULKING, 6A5KET5) 11. ALL INTERIOR RECEPT. AND SWITCHES SHALL BE INSTALLED w/ CASKETS. CALIFORNIA BUILDING EFFICIENCY STANDARDS REQUIRES MECHANICAL VENTILATION FOR RESIDENTIAL UNITS AS FOLLOW5: 1. KITCHEN VENTILATION - PER A5HRAE 51 TABLE 5.5 THE KITCHEN SHALL HAVE AN EXHAUST FAN w/ A MINIMUM VENTILATION RATE OF 100 CFM AND A NOISE RATING OF LE55 THAN SONE 5. THE FAN SHALL BE DUCTED TO THE OUTSIDE w/ A MINIMUM 6" ROUND FLEX DUCT OF LESS THAN 155' AND TWO ELBOWS OR FITTIN65 OR A MINIMUM 6" ROUND SMOOTH DUCT OF UNLIMITED LENGTH AND (2) ELBOWS OR FITTINGS. OR FITTINGS. 2. BATHROOM VENTILATION - EACH BATHROOM, EXCEPT AS NOTED BELOW IN NOTE 5 SHALL HAVE AN EXHAUST FAN w/ A MINIMUM VENTILATION RATE OF 50 CFM AND A NOISE RATIN& OF LESS THAN SONE 5. THE FAN SHALL BE DUCTED TO THE OUTSIDE w/ A MINIMUM 5" ROUND SMOOTH DUCT OF LESS THAN 75' IN LENGTH AND (2) ELBOWS OR FITTINGS. BATHROOM EXHAUST FANS MUST BE CONTROLLED BY A HUMIDSTAT CONTROL CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGE OF 50 TO 50%. 5. WHOLE BUILDING VENTILATION - AT LEAST ONE OF THE REQUIRED BATHROOM EXHAUST FANS NOTED ABOVE SHALL MEET THE FOLLOWING SPECIFICATIONS AS DETERMINED IN THE CALCULATION PROVIDED: + MINIMUM 60 CFM. + SONE RATING OF I + SWITCH CONTROL LABELED: "VENTILATION CONTROL" CFM = CONDITIONED FLOOR AREA/100 + 7.5(NUMBER OF BEDROOMS + 1) CFM = 161q/100 +7.5(5+1) GFM = Ib.1q + 50 GFM = 46.1q NOTE: AT LEAST 50% OF THE TOTAL WATTAGE 5HALL BE FfIGH EFFICACY. FIXTURE TYPE HIGH LAMP QTY. EFFICACY WATTAGE COMPACT FLUOR. YES 26 x 8 _ INCANDESCENT PENDANTS NO 60 x 2 X - X = - X - (COMPLIES If A _> B) TOTAL: Al H16H EFFICACY OR LOW EFFICACY WATTAGE WATTAGE )nA OR OR OR OR OR B: 120 RESIDENTIAL INDOOR LIQ+MN6 REQUIREMENTS ELECTRONIC BALLAST FOR FLUORESCENT LAMPS RATED >15W MUST BE ELECTRONIC, AND HAVE AN OUTPUT FREQUENCY > 2OkHz HIGH EFFICACY CRITERIA: TO QUALIFY AS HIGH -EFFICACY, LUMINARIES MIDST BE CERTIFIED TO THE CALIFORNIA ENERGY COMMISSION. LUMINARIES THAT CAN ACCEPT LOW -EFFICACY LAMPS AND LED LUMINARIES THAT HAVE NOT BEEN CERTIFIED DO NOT QUALIFY AS HIGH EFFICACY. WITH THE EXCEPTION OF DECORATIVE, MONOCHROMATIC ZEDS, JOINT APPENDIX JAb REOUIRES THAT LED LUMINARIES DESIGNED FOR INDOOR RESIDENTIAL USE HAVE A MINIMUM GRI OF 90 AND A GGT OF 2700K -4000K IN ORDER TO QUALIFY AS HIGH EFFICACY. FULL CRITERIA ARE IN TABLE 150.0-A AND JOINT APPENDIX JAb. LUMINAIRES NOT DESCRIBED IN TABLE 150.0-A MUST MEET HIGH -EFFICACY REQUIREMENTS LISTED IN TABLE 150.0-8: - <5W 501mm >5W - 15W 451mM >15W - 40W 601mm >40W golmm MANDATORY REQUIREMENTS FOR SWITCHING DEVICES AND CONTROLS: -HIGH EFFICACY LUMINARIES MUST BE SWITCHED SEPARATELY FROM LOW -EFFICACY LUMINARIES. -EXHAUST FANS MUST BE SWITCHED SEPARATELY FROM LIGHTING SYSTEMS. -LUMINARIES MUST BE SWITCHED WITH READILY ACCESSIBLE CONTROLS THAT PERMIT MANUAL OWOFF SWITCHING. -NO CONTROLS MAY BYPASS A DIMMER OR VACANCY SENSOR FUNCTION WHERE THAT DIMMER OR VACANCY SENSOR HAS BEEN INSTALLED TO COMPLY WITH SECTIONI50.0(k) BATHROOMS SECTION 150.0(IV REQUIRES AT LEAST ONE 1416H -EFFICACY LUMINAIRE IN EACH BATHROOM. ALL OTHER LIGHTING MUST BE HIGH EFFICACY OR CONTROLLED BY VACANCY SENSORS. KITCHENS MUST HAVE A MINIMUM OF 50% OF THE TOTAL RATED WATTAGE OF PERMANENTLY INSTALLED LIGHTING IN KITCHEN5 MUST BE HIGH -EFFICACY LIGHTING. KITCHEN L.I6HTIN6 PERMANENTLY INSTALLED INSIDE CABINETS MAY USE A MAX. OF 20K PER LINEAR FOOT OF ILLUMINATED CABINET. REGARDLESS OF THE NUMBER OF SHELVES OR DOORS PER CABINET SECTION, THE LENGTH OF AN ILLUMINATED CABINET MUST BE DETERMINED U51N6 ON OF THE FOLLOWIN6 MEASUREMENTS: -ONE HORIZONTAL LENGTH OF ILLUMINATED CABINET -ONE VERTICAL LENGTH PER ILLUMINATED CABINET SECTION -NO MORE THAN ONE VERTICAL LENGTH PER EVERY 40 HORIZONTAL INCHES OF ILLUMINATED CABINET. RESIDENTIAL OUTDOOR LIE444TIN6 REQUIREMENTS CONTROLS FOR SINGLE-FAMILY RESIDENTIAL BUILDINGS, OUTDOOR L16HTING PERMANENTLY ATTACHED TO A RESIDENTIAL BUILDING OR OTHER SUILDIN65 ON THE SAME LOT MUST GENERALLY BE HIGH EFFICACY. LOW -EFFICACY OUTDOOR LI6HTIN6 MUST BE CONTROLLED BY ALL OF THE FOLLOWING: -A MANUAL ON/OFF SWITCH THAT DOES NOT OVERRIDE TO ON. -A MOTION SEN5OR NOT HAVING AN OVERRIDE OR BYPASS SWITCH THAT DISABLES THE MOTION SENSOR, OR A MOTION SENSOR WITH AN OVERRIDE SWITCH THAT TEMPORARILY BYPASSES THE MOTION SENSING FUNCTION AND AUTOMATICALLY REA4TIVATE5 THE MOTION SENSOR WITHIN 6 HOURS. -A PHOTO CONTROL, ASTRONOMICAL TIME CLOCK OR ENERGY MANAGEMENT CONTROL SYSTEM THAT DOES NOT HAVE AN OVERRIDE OR BYPASS SWITCH DISABLING THE CONTROL AND 15 PRO6RAMMED TO AUTOMATICALLY TURN THE OUTDOOR LI6HTIN6 OFF DURING DAYLI&HT HOURS. LED QUALITY REQUIREMENTS: OUTDOOR LED LUMINARIES DO NOT HAVE TO MEET THE GRI REG UIREMENT IN JOINT APPENDIX JAb, BUT TH05E PERMANENTLY ATTACHED TO RESIDENTIAL BUILDING5 MUST HAVE A CGT OF 2'IOOK - 5000K IN ORDER TO QUALIFY AS HIGH EFFICACY. DECORATIVE, MONOCHROMATIC LED's ARE THE EXCEPTION TO THIS RULE. LED LANP50APE LUMINARIES ARE ALSO NOT REQUIRED TO BE CERTIFIED TO THE COMMISSION FOR COMPLIANCE WITH JOINT APPENDIX JAB. ELECTRICAL SYMBOLS COMPOSITION 5HINCL.E ROOF - FASCIA GUTTER TYP. AT ALL EAVES ------------- SOUTH ELF\/ATION NOTE: PROVIDE ELEC. POWER TO M.W. d VENT HOOD. VERIFY LOCATIONS w/ EQUIP. MFR. �--T -- - - - - - -r- - _ i SEDT I Obi A/5 NOTE: LAUNDRY ROOM LIGHTING SHALL BE HIGH -EFFICACY LUMINAIRES AND SHALL A C PERMIT# 4((- l` 62 BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR CODECOMPLIANCE L0.726-11,21 DATE (� -Z 6 - 1 l� NOTE: LIGHT d EXHAUST FANS AT BATH GLC. SHALL BE SUITABLE FOR DAMP LOCATIONS. NOTE: BATH 2 EXHAUST FAN SHALL SERVE AS THE WHOLE BUILDIN6 VENTILATION UNIT PER THE VENTILATION EXHAUST It WHOLE BLDG. VENTILATION REQUIREMENTS L EOTR I GAL. FL AN Revisions SINGLE POLE SWITCH T GLC. MTD. FIXT. D 516NAL PUSH BUTTON �3 THREE WAY SWITCH -�- RECESSED GLC. FIXT. LIGHTING TRANSFORMER D RHEOSTAT SWITCH HIGH EFFICACY RECESSED 01-6. FIXT. T_ PANEL BOARD �W DIMMER/5-WAY SWITCH L�r MINI RECESSED GL6. FIXT. D ELEC. DISCONNECT T TIMER SWITCH HN&H LEFMTD FIX rURE O HEAT LAMP L0 120v DUPLEX REGEPT. FLUORESCENT FIXT. B BELL 220 VOLT OUTLET 00 TRACK FIXTURE FEE* cion 110 V. SMOKE DETECTOR 0) GM IIOv CARBON MONOXIDE .N PENDANT LIGHTS ALARM w/ BATTERY �y U BACKUP N QUAD. REGEPT. SCONCE FIXTURE 4 EXHAUST FAN FLOOR OUTLET SPOT LIGHT FIXTURE F'F'�}-- FUEL 6A5 OUTLET O JUNCTION BOX �/ FLUORESCENT FIXTURE HB-}-µ- HOSE BIBS ® WHOLE HOUSE VACUUM CONNECTION GEILIN6 FAN w/ Ll6HT }---{ UNDER CABINET Z M - L16HTIN6 �--T -- - - - - - -r- - _ i SEDT I Obi A/5 NOTE: LAUNDRY ROOM LIGHTING SHALL BE HIGH -EFFICACY LUMINAIRES AND SHALL A C PERMIT# 4((- l` 62 BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR CODECOMPLIANCE L0.726-11,21 DATE (� -Z 6 - 1 l� NOTE: LIGHT d EXHAUST FANS AT BATH GLC. SHALL BE SUITABLE FOR DAMP LOCATIONS. NOTE: BATH 2 EXHAUST FAN SHALL SERVE AS THE WHOLE BUILDIN6 VENTILATION UNIT PER THE VENTILATION EXHAUST It WHOLE BLDG. VENTILATION REQUIREMENTS L EOTR I GAL. FL AN Revisions By T_ I N 1) L!7 0 L0 45o 00 FEE* cion cy) 0) .N L �y U N O .X �/ Z7 L Z M - dLO Q 1.4 H MD W NW W � W h' --i O r 1 �.cd O O z O 000 4-4 CO O 1-4 a co O Q W w Nw W Date 10-10-16 Spate 5HONN Drawn M.A. Sheet 3 Of 5 Sheets