Loading...
HomeMy WebLinkAboutB16-1920 000-000-000Builder/Contractor Responsibilities Drawing Validity - These drawings, supporting structural calculations and design certificdion are based on the order documents as of the date of these drawings. These documents dscribe the material supplied by the manufacturer as of the date of these drawings. Any changesto the order documents after the date on these drawings may void these drawings, supporting strucural calculations and design certification. The Builder/Contractor is responsible for notifyingthe building authority of all changes to the order documents which result in changes to the drawings, supporting structural calculations and design certification. Builder Acceptance of Drawings - Approval of the manufacturers drawings and design lata affirms that the manufacturer has correctly interpreted and applied the requirements of the oder documents and constitutes Builder/Contractor acceptance of the manufacturers interpntations of the order documents and standard product specifications,. Including Its design, fabricatim and quality criteria standards and tolerances. (AISC code of standard practice Sept 86 Section 4.21)(Mor 05 Section 4.4.1) Code Official Approval - It is the responsibility of the Builder/Contractor to ensure the all project plans and specifications comply with the applicable requirements of any governing building authority. The Builder/Contractor is responsible for securing all required approvals and permits firm the appropriate agency as required. Building Erection - The Builder/Contractor is responsible for all erection of the steel aid associated work In compliance with the Metal Building Manufacturers drawings. Temporary support; such as temporary guys, braces, false work or other elements required for erection will be detemined, furnished and Installed by the erector (AISC Code of Standard Practice Sept 86 Sectior 7.9.1) (Mar 05 Section 7.10.3) (CSA/Sl6-09 Section 29). Discrepancies - Where discrepancies exist between the Metal Building plans and plans fir other trades, the Metal Building plans will govern. (AISC Code of Standard Practice Sept 86 sction 3.3) (Mar 05 Section 3.3) Materials by Others - All Interface and compatibility of any materials not furnished by:he manufacturer are the responsibility of and to be coordinated by the Builder/Contractoror A/E firm. Unless specific design criteria concerning any Interface between materials if furnished a. a part of the order documents, the manufacturers assumptions will govern. Modification of the Metal Building from Plans - The Metal Building supplied by the manufacturer has been designed according to the Building Code and specifications and the loads shown n this 9 9 9 P drawing. .Modification of the building configuration, such as removing wall: panels or braes, from that shown on these plans could affect the structural integrity of the building. The Mdal Building Manufacturer or a Licensed Structural Engineer should be consulted prior to making on, changes to the building configuration shown on these drawings. The Metal Building Manufacturer wl assume no responsibility for any loads applied to the building not indicated on these drawings. Foundation Design. The Metal Building Manufacturer is not responsible for the design, materials and workmanship of the foundation. Anchor rod plans prepared by the manufacturer are intended to show onlylocation, diameter and projection of the anchor rods required to attach the Metal Building Systen to the foundation. It is the responsibility of the end customer to ensure that adequate proviions are made for specifying rod embedment, bearing values, tie rods and or other associated Isms embedded in the concrete foundation, as well as foundation design for the loads impoed by the Metal Building System, other Imposed loads, and the bearing capacity of the soil and cher conditions of the building site. (MBMA 06 Sections 3.2.2 and A3) BUILDING DESCRIPTIONS Building ID Width Length Height Slope Building A 60'-0 82'-0 18'-7 1 1:12 J"P A325 BOLT GRIP TABLE GRIP LENGTH BOLT LENGTH NOTE. - FULL THREAD EIGAGEMENT IS DEEMED TO HAI7 BEEN MET WHEN THE END 7F THE BOLT IS FLUSH WITH NE FACE OF THE NUT. WASHER REQUIRED ONLY KHOV SPECIFIED. GRIP WASHER MAY BE LOCATED UNDER HEAD OF BOLT, UNDER NUT, OR A', BOTH AT LOCAPONS NOTED ON EREC79N DRAWNGS ADD 5/32" FOR EACH WASHR TO MATERIAL THICKNESS TO DETERMINE GAP. 0 TO 9/16" 1 1/4" F. I. Over 9/16" TO 1 1/16" 1 3/4" F. I. Over 1 1/16" TO 1 5/16" 2" Over 1 5/16' TO 1 9/16" 2 1/4" Over 1 9/16" TO 1 13/16" 2 1/2" Over 1 13/16' TO 2 1/16" 2 3/4" LOCATIONS OF BOLTS LONGER THAN 2 34" / NO!!ON ERECTION DRAIMNGS F.T. DENOTES FULLY THREADED y Ctallic building company mm 7301 FAIRVIEW HOUSTON, TEXAS • P.O. BOX 40338 ZIP 77041 (713) 466-7788 ZIP 77240 ENGINEERING DESIGN CRITERIA Building Code .............. 2013 CALIFORNIA Cover Sheet Building Risk Category ... Normal (Risk.. Category II) actual deflection Roof Dead Load may be less depending on actual Superimposed ................. 2.54 psf member length. ; Collateral .... .. , . 3. 50 psf BUILDING DEFLECTION LIMITS...- (3,00 psf Acoustical Celling 0.50 psf Other) Sidewall BLDGA WALLSWC Roof Live Load .................... 20.00 psf no reduction Ceiling Type 1 Acoustical or Wind Endwall BLDGA WALLEWD Ultimate Wind Speed (Vult) ... 110.00 mph Roof Limits Nominal. Wind Speed (Vasd) .... 85 mph (IBC section 1609.3.1) Purlins Panels Serviceability Wind Speed .... 72 mph Live L/ Wind Exposure Categpry C 150 Internal Pressure Coef (GCpt) 0.18/-0.16 Snow L/ Loads for components not provided by building manufacturer 180 Corner Areas 25.25 psf pressure -33.67 psf suction Serviceability Wind L/ Other Areas 25.25 psf pressure -27.35 psf suction P P 180 e maxi required based on IDs These values are the um values re m q 9 ft area. Components with larger areas may have lower wind loads.. P 9 Y 120 Seismic Total Uplift L/ Setsmlc Importance Factor (Is) 1.00 N/A SeismicDesign Category ...... D Frame Limits Soli Site Class .............. D Stiff SolI Portal Frame Sidesway Ss . . ..... 0,597 g Sds ... , , 0, 526 g S1 ... . .... ... ......... 01260 g Sol ..... 0, 326 g Analysis Procedure ........... Equivn lent Lateral Force Snow H/ Column Line 1 & 4 2-3 SWA & SWC Basic Force Resisting System B3 C4 B3 Response Modification Coefficient (R) 3.25 3.50 3.25 Se i sm I c Response Coefficient (Cs) 0.162 0.150 0.162 Design Base Shear in k l ps (V) 2.37 4.40 6.98 Basic Structural System (from ASCE 7-10 Table 12.2-1) Crane H/ B3 - Ordinary Steel Concentrically Braced Frame C4 - Ordinary Steel Moment Frame Portal Service Wind H/ DEFLECTION CRITERIA The material supplied by the manufacturer has been designed with Cover Sheet the following minimum deflection criteria. The actual deflection E3 may be less depending on actual load and actual member length. E5 BUILDING DEFLECTION LIMITS...- BLDG -A Sidewall BLDGA WALLSWC E7 Ceiling Type 1 Acoustical or Other Endwall BLDGA WALLEWD E9 -E10 Roof Limits Rafters Purlins Panels Live L/ 180 150 60 Snow L/ 180 180 60 Serviceability Wind L/ 180 180 60 Total Gravity L/ 12D 120 60 Total Uplift L/ N/A N/A 60 Frame Limits Stdesway Portal Frame Sidesway Live H/ 60 Snow H/ 60 ServIceabl U ty Wind H/ 60 Seismic Drift H/ 40 40 Crane H/ 100 Portal Service Wind H/ N/A 60 Total Gravity H/ 60 Service Seismic H/ 40 40 Wall Limits Limit Total Wind Panels L/ 60 Total Wind Glrts L/ 90 Total Wind EW Columns L/ 120 The Service Seismic limit as shown here Is at service level loads. PROJECT NOTES Material properties of steel bar, plate, and sheet used In the fabrication of built-up structural framing members conform to ASTM A529, ASTM A572, ASTM A1011 SS, or ASTM A1011 HSLAS with a minimum yield point of 50 ksl. Material properties of hot rolled structural shapes conform to ASTM A992, ASTM A529, or ASTM A572 with a minimum specified yield point of 50 ksl, Hot rolled angles, other than flange braces, conform to ASTM 36 minimum, Hollow structural shapes conform to ASTM A500 grade B, min 'Mum yield ppolnt Is 42 ksl for round HSS and 46 ksl for rectangular HSS. Materlal properties of cold -formed light gage steel members conform to the requirements of ASTM AI011 SS Grade 55, ASTM AIOII HSLAS Grade 55 Class 1, ASTM A653 SS Grade 55, or ASTM A653 HSLAS Grade 55 Class 1 with a minimum yleld point of 55 ksl. For Canada, material properties conform to CAN/CSA G40.20/G40.21 or equivalent. Bolted Jolnts with A325 Type 1 bolts greater than 1/2' diameter are specified as pre-tensloned joints in accordance with the Specification for Structural Joints UsingASTM A325 or A490 Bolts December 31, 2009. Pre -Tensioning can be accmplished by using the turn -of -nut method of ti htenln calibrated wrench twist -off -t e 9 g, to tension -control bolts or direct -tension -Indicator ns acceptable to P the Inspectin? Agency and Building Official, Installation Ins ecti on requireents anpretensioned joints (Specification for Structural Jlnits Section 9.2) using turn -of -nut method Is suggested. The connections on this project are not stip critical. Design criteria as noted Is as given within order documents and Is applied In general accordance with the appplicable provislons of the model code and/or specification Indicated. Ne ether the metal building manufacturer nor the cert Ifying engineer declares or attests that the loads as desI@noted are proper for local provisions that may appp Ly or for site specific parameters. The design criteria Is supplied by the builder, project owner, or an Architect and/or Engineer of Record for the overall construction project. This metal but ldlng system Is designed as enclosed. All exterior components (I. e, doors, windows, vents, etc.) must be designed to withstand the speclf led wind loading for the deslggn of components and cladding In accordance with the specified bullding code. Doors are to be closed when a maximum of 50% of design wind velocity Is reached, The materials by the manufacturer will be fabricated in a facility that has received certification of accreditation for the Manufacturers of Metal Bullding Systems (AC472) from International Accreditation Service (IAS). This certification Is recognized under Section 1704 of the IHC for approved fabricators. Framed openings, walk doors, and open areas shall be located In the bay and elevation as shown in the erection drawings. The cutting or removal of glrts shown on the erection drawings due to the add Itlon of framed openings, walk doors, or open areas not shown may vold the design certifications supplied by the metal building manufacturer. X -Bracing Is to be Installed to a taut condition with all slack removed. Do not tighten beyond this state. Using standard 5x5 eave gutter with 4 x 5 downspouts, the roof drainage system has been designed using the method outlined In the MBMA Metal Building Systems Manual. Downspout locations have not been located on these drawings. The downspouts are to be placed on the building sidewalk at a spacing not to exceed 54 feet with the first downspout from both ends of the gutter run within 1 feet of the end. Downspout spacing that does not exceed the maximum spacing will be In compliance with the building code. The gutter and downspout system as provided by the manufacturer Is designed to accommodate 4 In/hr rainfall Intensity. The wall construction by others at building(s) A and sides) A has a self weight of 5 psf. This wnht has been utilized in the design considerations for the building's seismic design. The wall support beam and connection to frame is not by MBM, Building Separation In frame direction, The calculated Maximum Inelastic Response Disp lncement for this bullding In the taternL cilrectlon Is 2.0 Inches. Section 12.12,3 of ASCE7-10 requires a minimum separation of the SGuare Root of the sum of the squares' between this building and the adjacent building to avoid damage. The required separation may be forger depending upon the calculated drift for the existing building. Metallic has no responsibility for the behavior of the existing building, I6 E �CHrIf Drawing Index F1 AnchorRod E2 Anchor Rod Details F3 Reaction Drawings E1 Cover Sheet E2 Primary Steel BLDGA E3 Roof Framing BLDGA E4 Roof Sheeting E5 Sidewall BLDGA WALLSWA E6 Sidewall BLDGA WALLSWC E7 Endwall BLDGA WALLEWB E8 Endwall BLDGA WALLEWD E9 -E10 Main Frame Cross Sections Ell Connection Detail R1 -R4 Erection Guides R5 -R13 Construction Drawings R14 Trim Profiles r O S• - c./7 PERMIT # 3-( BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR CODE COMPLIANCE DATE '*" BY NOV 02 201uq REVIEWED FOR CODE COMPLIANCE NOV 10 201' INTERWEST CONSULTING GROUP 13TJTTF- ( 0T.1NT OCT 2 6 2.616 DEVELOPMENT SERVICES a U 031 w 0 0M ❑ ❑ Fw _ man q m � zamzo 0>az in �UODU �OVOz Oz 0< J 1:5 O UU' NUn] O Sco/e: NOT TO SCALE Drown by JOE 7/14/16 Checked by. JAM 7/15/16 Project Engineer. SG Job Number: 15-B-39475-1 Sheet Number El of 11 )ears hereon is an employee the manufacturer for the terials described herein. Sold it or certification is limited the products designed and nufactured by manufacturer y.The undersigned engineer Is the overall engineer of ord for this project. cold W. Bennett. RE No. 0050732 �_ I l f I I i III I III II I rel IIS _r _I- i I 24 e7- c,ryGu7 .F sr:� 3r: rP n m 3- 21 D 20'-G 20'-0 C� O m (w I f I .._.___�. E.. x wasp i 1 I �m (, p- rn_C - <= X -ami a n �m o m om -� O O d y A r 0. yap Z ^^ l/ m a X 1 SO I -.gs 3 faros 01 -,;. �, ii 1 _ _ agcz OZN C) ;o X m A D y m Z pli,m m o-d.b 59'-6 Q y0_b )D. - {! LO z Cr C zm mzm !r^0o mOfwJ ¢. T a i E D 7 i! X BRACE 20'--0 20'-0 20'-0 60'-0 OUT/OUT OF STEEL 3r: rP n m 3- 21 D 'f1 C� O m (w 77 mil �Z c: z < Om �m (, p- rn_C - <= X -ami a n �m o m om -� O O d y A r 0. yap Z ^^ l/ m W y 0 X 1 SO I -.gs 3 faros 01 -,;. �, 3r: rP n m 3- 21 -78 _-s g D 2 O] 3 01 D Z m (w i C (, p- f T lb tb O h 'i Vl a n Ayoo m R om w O d n,o aa�u A A yap W y 0 X X 3 L U) OZN C) ;o 5_ ZZO Z Z W y Z pli,m m o-d.b w Q y0_b )D. - {! LO z Cr C zm mzm !r^0o mOfwJ ¢. T a i E D 7 -78 _-s g D 2 O] 3 01 D Z m (w a a n Ayoo m R m m O d AZA wow A A A W y 0 X X X U) OZN C) ;o 5_ ZZO Z Z W Z A m N to ti C z - {! LO z C zm mzm !r^0o D r 6 c. 73 i ENOWAU f0 T 17 -'EEIT. -f 4 it i�n70 nI G w Z _ Z n Q M m C c� o 0 � M d ryy � b 6fa"r'�a Z M r 6 c. 73 i ENOWAU f0 T 17 -'EEIT. -f 4 it i�n70 nI G w O BOOR ViIO71 I p F.O. 'lIDTN 3A0 Iz ijFun F Mir IV rEND S!CEWALL IMT Of CONI.11 �E3 N {J Ln N 'tl D m hal i v �w mnrD ni, 1 ILS H., u+� O r. m II G'� -101 7 0 ,.o a I'lLNEDriO VICONC� M r i A n l' 1 r`` �w i A ° 3 3 SL ro m G z U- w t1p 2� t5 � (fir w� 3 n 1+ 3 �a� a O BOOR ViIO71 I p F.O. 'lIDTN 3A0 Iz ijFun F Mir IV rEND S!CEWALL IMT Of CONI.11 �E3 OF N 'tl D m hal i v �w mnrD ni, 1 ILS H., u+� O r. m II G'� -101 7 0 ,.o a I'lLNEDriO VICONC� M r i A n l' 1 r`` �w i A ° '�' F� io ro G z U- w t1p 2� t5 � (fir w� 3 On 2"rn 7 A O aaP O'o Z m k` ,a O BOOR ViIO71 �1I ijFun F 3 rEND S!CEWALL OF N 'tl 2§ 8.. `Ln 1' CUT OFA D ul 17 / r.. STE,. L w D -aa M :Y r (2 1-' I_fi I I i N of Si7 Date O 6" SIOEWALL OUT OF 7 CONC. 6" m OUT OAU - u OUT CONC. O S!CEWALL OF STER I'lLNEDriO VICONC� On 2"rn 7 A O aaP On On Z k` c /<¢ 10 0. 7 'mrt°3�m3n$s a o i a o n any metallic building company o m 3 m a 7301 FARM • HOUSTON, TEXAS • PA. BOX 4= ZIP 77041 (713) 463-77BB 7P 77240 < NO o n Customer. Project Name &Location: W51- ° N Pc o n Q f i v,n,_a l m �-% > o v min �c 0 ,..0 . D -- '' m .y GINNO CONSTRUCnON INC MAISIE JANE'S 3 w a n n m I O 297 CONVAIR AVE 5/E 2 3764 HEGAN LN CHIC.O CA 95973 - CHICO CA 9.5928 o BRIAN GINNO o n 3 y Growing 5totus: Prelinrincry ®For Construction Pemrit 1„ � � � (Naf Far C.onsfnictinn) � u N For A royal py For rgctor lnstalloti�{r N (Not For Constnretion) 2§ 8.. `Ln 1' CUT OFA D ul 17 / r.. STE,. L w D -aa M :Y r (2 1-' I_fi I I i N of Si7 Date O 6" SIOEWALL OUT OF 7 CONC. 6" m OUT OAU - u OUT CONC. O S!CEWALL OF STER I'lLNEDriO VICONC� On 2"rn 7 A O 0 O On On Z Description 8y I Ck'd 3 r cP ,R Irl 1 Th -ll M Y Lh T(5y'iE31M C F'1.4CC4r` LMd �:a rCC<e1�^e. J'" HL -1 f OR YL vP, 1C CE UMk D A .w -AD C:9tA^ b ALJ qL, IA d 5b D t C 1 F 1 2.A 1 O J _ Ifi¢ fit 1R tF L.0 ......###..._0.0 03 00 OO dy_ iE tt�bl OA M 124r 64 0^ I%1 W2 iS�SO t , 1.1 Oi 19b ET 1¢ f0 lY'J 7 "ib� 00 3LL� A r3 ?N.` 02 -A3_-00 i 4 5 14 JJ 1213 rt i,I 34 t L2 Wt.2 {� LrtA 'F i3 1 - Jam_ ! RUPIq M Vii- J.i 1aC t Jt 4?i - 5 .,"a P2 13 OO D P�GJ LM ,J P rh,, Mid LOe,d S15 ter• Firm tt�i �_ DL Roof Card L4N LL R,,? Liw Loath (:Dii Renf a,,,!=:s'nrci lava EG Lv?OUR Se!drM LnM [paal:a! to run. 01 home) PCOPEO UFeard Ac:"ng Rid Onx:s Load rnm Lcn;!i=. Su1,:mfr. V2 L2 Wt.2 Lelard Prnnnry fA:d Lexi WL3 L,0e& i'r!ncr: V d Lead i%. LM ,J P rh,, Mid LOe,d S15 Lot«d P6T.ry Wind Loa! Wrg _uiwa'F,!M,y W"d Low 0 L&,oI F'r^mv}' ft., Lnad 55.9 Lvter.J prMory +!.ad LOM !.'F;il Luntll}cdlndl M.,y 'Xmd LCd n cT:l!'L': LlpWttC k9M14 R:'d RY.gIN t.OP} (1i#YI LGTGSUG. �4,ind L'se2 Lma%`vaTno! P I'Tar, Mid L�j i,'A43I LmnORvdI.i,i Primvy R1ed t vad LK4 Lm+3fw` dnc F',^Imwp smd Lo RrLW,-W Oct d AvraO Rcd 8mc¢ Lead franr 1,01t Wnd 0 ;3D EQ v.n'n.d Ac1'g9 Rod S,rans ..cnd fi+. L-,,,, NbTs]S 1', THE REACCG! a PRCY;L'-„ D A31 BA57D LNG =HE (.?DER DoUwEN'.'S AT 14';5 ME ^_i'!.lP.UNG. A.P21 CHJKN M5 TT i;Vi'ZINC LGAL'S 01 0!t'ENS0,15 L4.tY • N'a FF. C. -A, "C;a.S. THE Rr FTONE e !" 11J.)P..R .:DrC AND 4['OED• BY ANY "EliNE MA01NG. 'a) Tli£'. REA+'_T!GNS f'!{pbiCG+3 HAVE SEEN CR!i ATED VOT4 THE FLU! O'VING L'OYOUT (UHl.E%S ,'i "D ,,,)A :ic,v;TI;jN YABLE iS PROiADCQ kA T! 11!- RFAC :TONS FOR EACH La`.0 GROUL" n} RSgiD FRAM' Iol (as !EFT ANRIGHT COLUMNS ARE Df:'K'F:!°'PiJ AS R' VE&1NG THE LEFT S@GE OF IME SL!!DDING, AS S 0AN C;•! THE ANCHOR R00 'sRA?'il.".'GFD . O,Y, THE OUTSIDE OF 1:i- RUB -VNO. (b7 !NT_RRA COLLIIANS ARE SPACED F'04 :.EfT SIDE TO Richl EIDE. ( iEINCLE SL:7=51 3usLE!!-e;S {al LEFT CGLL'ifN IS TNc_ L.O'ri SIO:. '✓IXU''. fbi Dl,,H7 COO IS r, H?CA1 SM D03iFl. (c? 3 TER.ifr C^LU:.I:dS ARE S ACT.'✓ FROU L W SME TO NIGH SIDE. o) U.DWIL {t), LEFT AND R.10,T COLL:MNS ARE IM"MiN':D AST AEMNG THE WALL FROM Tl F OUi'^h., (7.) NTERIOR COL UM ARE SP;,;E F!7 Y]M LE -r 1 R!GK',. %i OXHCIR 5`.'E• !S r IS B. SHE dR A.,, Tc0.:,ils AT THE R:ATTCNi OF 1'Y1:;: 6A.TF. PIAk-, I<USNa" H CS, ';MET rHCR ROD ANO ME'UIOD � L' ' T;AN: 'i0' E FOiP'1GAtTOiI DARE TO BE Dr"tEtt3,NTE V TNFEC'UND1TOf'' ENS IHFEn. el AN':HOR POPS ARE r!,. 38 M V[ RAL UNLESS NOTED OT `R%MF:'. ON 7'FIC AYCNCR POD LAYC".!T DP.Aty, iC *) v_SRAJINt, (1)INBR.MEMC. REACTIONS ti.a?d� WEEN ":C UDEG IN VALUES L:NOWN IN ^nE r=Ar,;�.N ?.aeLEG. (2)FU21BC AP UDC BASED i3U'i"C1NG C(X:tG, 'b'r:?! K -BRACING IS 111"E,;!N's, E 81)Et'i4LL. MSVAIUM. SESkAIO Lr DS (rt9V?e9 ✓PID PcDvo)) 3O NT, IoCLULE I$ AMPSJF!CATG31 rACTOP, 4. (3)FOR CANADA EUiLDING CODS (NUC) 1ud_'N M-URACnN.G IS PRESENT IN THE SIDEWAL_ Oi ENOWA.LL, R2CMDUAt OPIG.II.D:±cLI S:ISMH: LOADS C- HUK & RBtWcG7 ARE G 1 IPUEF By FORCE PEPUCTION FGE• Rd, b4 J SP- FUD SH P' FEKOD ' EC h t AC' -A! RATS iE! o dO.2} !S ':PEA -EU Tr4AF: 0,45. 31 RVAGOONS ARE PR9 frD AS U Fa TORUD FOR EADO LOAD GROUP APPUE0 TO THE 7t MN THE FOUNDATION T Oro 14u- APPLY THE: APPROPRIATE'LOAD FACTORS AND 'cV NF'!.E RET TLb� ,N Ar-rR AKIM WMH THE B I I'NG .COH DES ON SPETLATIONS TO Lt'f5nh,.-ec SEARi1NC FRE ZURES hid... C.,.......+. D£:, OUP.. T!i.. F,ACTCi<S AF rL?ED I'll LDAD CROL4'S rOQ TI -:i STEL C+✓.UI^N EfSISZb MAY BE OIFF-M-NT VAN E FACTORS USED IN THE FOUN 'AT`F.v DF31rN. of FOR PROo':CTSr USiPG ULTIMATE DE`3iG;3 lA1NO y °DS SUCH AS 2012 IDS GR 2014 PLOEH),A SUILtNA,G CODE, IiE 1".NO LOAD REACIOidS ARE AT A E:`_ Z¢1 VALUE VAI! A LOAD FACTOP OF 1.0. T.e MANAO q!1 Ef. GOES NOT PROP t AAk' 'iA?" l +„k tLf-v Na.T:GN CE:A ! r V ivt T l IND/'DUAL LCA -1 RCt4T 0�4� 1B MAY Rc l -D BY ME FUJR;yAllat,-S t i ;ER TO n YE MRNE INE APV ABLE u.A,D c WCIAd l ,3 FOR r1 R ^Fd N P _C LAR S A'+o P:Low FOR AN EOO dtI4t AlF(JONDATON DESIGN, .au§51`Eb2S»b4.z"' 4'r`>F�R'=...:6`XSlA1±LiWK M�Sa"/.s!A.':GfiA XB»�'igz:.+'FmET[6?Y•D PtJS.. it -3 104F_15:^MV W-ACRFAF KBEA",'S EI a 0, HL H2 IY1. 1V1 PV2 1-D 1-C 1-B HR C -:LIMN 1 C t 1-C 1-B 1-A LOAD CROUP tP N LL Ht A L1 H2 V2 L2 HR VR LR 0 00 0e U 0 1.2 0. 0 1.2 0 0.0 07 0. r OO a; C 0 '.1 0. 0 1.1 0 0.0 04 0. i a0 -o U 0 GO 0, 6.0 A6 0.0 2:3 0 Wi Oi 3,3 0. tl. 8 &2 0. -&2-3-8 0.1 -3.3 1.8 Si 0. 33 0 _ 0 82 4. -0.2 -R.2 0.1 3.3 -2.2 W2 1 1 '.3 0. U l-.3 00 2.9 .9 -112 .0 0.0 0.1 3.3 0 A" 31 3 3 a. _ - -11.2 0 0 -5.3 0.0 -3.3 0 It. U. ).0 0. G. 1.0 LO c 0 0 0, 0. . to -1.0 0. -a.- LO 0. 0. 0. 0. G. G U -07-0. 0. 0. 0. 0. 0. 0.1 F -iJ C 0. 0. 0 a 0. 0. -0 -0.1 Lsr x n D i DAD C ERA AL LOAD LIVE LOAD UWELO Ve LOAD W+ VIM LOAD AS AN ACTINO PRESSURE W'- ND LI A0 AS AN OUTVD O AG'V.» SUC^ON WR WIND RIGHT WIND FORCE FROM, 'RIC R WIND FORCE MOM THE: LEFT TIE Ve',ND rRCE FROM TIE LFT EW.R ER EAFTPOUAKE FORCE FROM RIGHT EARTHQUAKE FORCE ACING OUTWARD EAF:THQUAY,E FOR'ZEM LEFT C, E- ASOM EARTHOU.AKE FORCE ACTING INWARD E- EARTHOUAHE FOR.OE ACING OUTWARD IPPORT REACROHB FOR I M: All Y tone are h RFAMKI 1MTINNR HL FRAME DESCRIPT 1XIER R.Ufi:aagguutlsr DATE: T/CS%10 PAC£EW-2 EWN. AJD NPNLJ0475A RX.REMIAMG1 4-A 4-R 4-C 4-D LOAD CROUP LOAD GROIIIP D OE4[�PTPN DEAD LOAD C COLLATERAL LOAD L LIVE LOAD W+ WND LOAD AS AN INWARD ACING PRESSURE W- WIND LOAD AS AN OUTWARD ACING SUCIM W.R WAND FORCE FROM THE RIGHT ft WIND FORCE MOM THE: LEFT E+ EARTHQUAKE FORCE ACING INWARD E- EARTHQUAKE FORCE ACING OUTWARD ER EARTHQUAKE FORCE FROM RIGHT EL EARTHQUAKE FORCE FROM LEFT IMIii I&O2:2> ...-.-_.- ... N n REVIEWED FOR CODE COMPLIAN NOV 10 2016 INTERWEST CONSULTING GROUP rm 4'd8X18 Mel0 rc 1,8X10 l,SXt 9 W8X7 0 1,8X10 6 V C7 m O _. p it s i .- C Z CO Z o 0 m r� m C`Y m C Si a n� m 0 ^^U� V) C gW. 7 i '' Cf C O n m `✓{8x10 NI X10 nIn in m, W G L I(�aOCF(s(� �xC C) i j I CA 6 6C U M i � n Reeislon Date Description By Ir 9 4a i I �f5 Iw f, f� �m Z m p M _ I i 1 G) cn r' ro co `✓{8x10 NI X10 nIn in m, W G L I(�aOCF(s(� �xC w5XI0 W8X10 20' --J C) O CA 6 6C U M i � n Reeislon Date Description By cn C: z o m CD-� < i I I �m Z m p M _ I i 1 G) cn r' ro co �.n aa3c m'o � �'a � 2 M � 1a a .10 g �t�P�6l�4��p�6 ri - S0 FAIR 730RE. • HRISTW7. 7EW • P.O. BOX 40M N\\ ,/x ➢P 77041VI(713) 466-778 21P 77240 3'g 2,2. 9., 0 W Q Customer., Project Name & Location: aim \\ -` l n o y GINNO CONSTRUCTION INC MAISIE JANE'S N„w p9= d"m Cm m m 3 ro a n� a I I < I m 297 CONVAIR AVE STE 2 3764 HEGAN LN «« x N N N « « a x x x x N CnN N (P (P (T N N N N N w « x N [T m " m cNi N N N N N N CHICO CA 95928 = d I N 1 I� O w5XI0 W8X10 20' --J --'7i C) O CA 6 6C U Z n Reeislon Date Description By cn C: z o m CD-� < �m Z m p M _ _gi�g 'A- gli� G) cn r' ro co �.n aa3c m'o � �'a � 2 M x a `•° g �t�P�6l�4��p�6 ri - S0 --'7i r' -o aoa W o o? a m o Ho m Vy o. o c Reeislon Date Description By Ck'd ` _gi�g 'A- gli� �.n aa3c m'o � �'a � 2 M x a `•° g �t�P�6l�4��p�6 ri - S0 FAIR 730RE. • HRISTW7. 7EW • P.O. BOX 40M of Ma mm ➢P 77041VI(713) 466-778 21P 77240 3'g 2,2. 9., 0 W Q Customer., Project Name & Location: p[° -am,o� w ° ��' -.o -` l n o y GINNO CONSTRUCTION INC MAISIE JANE'S N„w p9= d"m Cm m m 3 ro a n� a N i m 297 CONVAIR AVE STE 2 3764 HEGAN LN — w n 'm n w ' ' m m " m cNi CHICO CA 95973 CHICO CA 95928 = d w a BRIAN GINNO m g 3 p v 0 NI °1 Drawing Status: Preliminary Pem it o N � FrCanstruction m m ❑LNotAFar ❑For Frector Installation n ConsWet7on) ro b' r i I I f ?i z »Z Zit -1j 1 1 29'-4i 29'-1§ I TI LTP to -8 I 10'_4 i 10-47 I LTP 10'-8 I ` i 29'-41 � ) —._.__._--__. i I 1 7.9'-1 } I ! I I I LTP 1o' -s 1 10'-4110'-4 I LTP to'—s I 9'-31 I I I I 29-1} 29 •�} 29'-11 29'-41 29'-1} 29'-41 29'-1i 29'-41 29'-1} 29'-44 29'-1 § 29'-44 LTP 10'-6 I 10'-4 10'-41 I LTP 10'-8 9'-31 I I I I 29'-1} 29'-41 29'-1} 29'-41 29'-1} 29'-44 29'-1} 29'-41 �. 29'-t} _ 29'-4} I I I I I 9'-0}LTP to' -8 10'-41 10'-41 LTP 10'-3 I 3'-3 I I I I 29'-1l I 29'-41 I i 29'-1} 29'-4§ 29°-tj 29°-41 I 29'-1} 29'-41 29'-14 29'-41 O -n rj �Z o rn'= M 2 o <sl � C 0 G) ai M < s a r�f II AF v n C u r C Zit -1j 1 1 29'-4i 29'-1§ I TI LTP to -8 I 10'_4 i 10-47 I LTP 10'-8 I ` i 29'-41 � ) —._.__._--__. i I 1 7.9'-1 } I ! I I I LTP 1o' -s 1 10'-4110'-4 I LTP to'—s I 9'-31 I I I I 29-1} 29 •�} 29'-11 29'-41 29'-1} 29'-41 29'-1i 29'-41 29'-1} 29'-44 29'-1 § 29'-44 LTP 10'-6 I 10'-4 10'-41 I LTP 10'-8 9'-31 I I I I 29'-1} 29'-41 29'-1} 29'-41 29'-1} 29'-44 29'-1} 29'-41 �. 29'-t} _ 29'-4} I I I I I 9'-0}LTP to' -8 10'-41 10'-41 LTP 10'-3 I 3'-3 I I I I 29'-1l I 29'-41 I i 29'-1} 29'-4§ 29°-tj 29°-41 I 29'-1} 29'-41 29'-14 29'-41 O -n �Z o rn'= M 2 o <sl � C 0 G) ai M < s a v n _ m m r A vm� mrn0 zr.os pO0 A OM— AZ<M_ i� Z< Ong a czm WmN IVgy_n11� � � a° -Q � ! m m ❑ Aw A revs! ctlon) Fos Erector /nsfa/lafion !i KEY PLAN II ..... _L J- - _... _... _ _ —i_- ___ __- �_y -1 __ I i -1--i __. _ _L_ I __. _ c c SCHEDULE OF ACCIESSORIES NO. REDD DESCRIPTION 1 12'--0 X 12'-0 FACTORY LOCATED FRAMED OPENING 1 3070 STANDARD NON -INSULATED SWING DOOR W/ N0, OPENING LHO CYLINDRICAL LEVERLOCK HARDWARE KEYED DIFFERENT W/ WEATHERSTRIP, THRESHOLD ANDS SWEEP. REFER TO DETAILS ON INSTALLATION OF WALK DOOR. REFER TO DETAILS ON INSTALLATION OF FRAMED OPENING. USE STANDARD WALL PROCEDURES TO ERECT THE S!DEWALL AND ENDWNALL PANELS. I� N3X18 dD dD SIDEWALL ELEVATION "SWA" AT GRID LINE "A" JUT 1 E C"+HAUN i kA REVIEWED FOR CODE COMPLIANCE NOV 10 2016 INTERWEST CONSULTING GROUP —�8X3.5E19-^------�- 8X3.5E14 SX3.5E14 \ r \\\\OP�cN, TO ROOF/LINE OF EXISTLNG/151UILDING (NOT BY MANUFACTURER) e\ I� N3X18 dD dD SIDEWALL ELEVATION "SWA" AT GRID LINE "A" JUT 1 E C"+HAUN i kA REVIEWED FOR CODE COMPLIANCE NOV 10 2016 INTERWEST CONSULTING GROUP E'At. Svec SWk P8R WALL PANELS PAN0. COVE@AG– = S-0 COLOR = T00 P! TL F f- R Grs = PBS -2 r IJ u° f=are and Trim as reowieed cer Ccns'ructon Detaii-a 1 c 4 4 4 63 N8X10 WSX10 SIDEWALL ELEVATION "SWC" AT GRID LINE "D" 8X3.5: -i4 8X3.5E14 SX3.5E14 � r I I I w i c� I cn w I u� io 1 1 8X2.5Z12 \\ 8X2.5Z12 8X2.5Z12 co I m i ro I /—� ca I u+ I ra I ro I m I m I ca 1 rc 1 m 1 m I �o I v�� co 1 rc I ro I J cPa r [a I i is [,a_ t0 iA V] 8X2.57i2 8X2.5Z12 \ / 8X2.5Z12 ca is [O \ / [O yJ W W x W of is I Off) [a I I I M I --^ ` I 2,X2.5Z12 SX2.5Z12 \\ 8Y2.57.12 I // / e\ SX2.5Z12. / 8X2.5Z12 'QL'F\\ SX2.5Z12 I / \ 63 N8X10 WSX10 SIDEWALL ELEVATION "SWC" AT GRID LINE "D" ___-_I iq), WALL SHEETING ELEVATION "SVlC BLDG "A" cy BUILDING DTJSI t� ^rn n;Y USACY.LAP REVIEWED FOR CODE COMPLIANCE NOV 10 201'1 INTERWEST CONSULTING GROUP N 0 c ,o C C c SC a Cn mra o t N% V C kk Z N e® Z Wyl l Em LZ IN ❑ �o IN V G CI L1 o L ZN4xlLV zN El 110 F- 0 Z 0 3 0Z03 O OVOZ •c _. Z r, `3 U <�NVm O Scale., NOT TO SCALE Drown by JOE 7/14/16 Checked bg JAM 7/15/16 Project Fngtnear. SG. Jab Number: 15-8-39475-1 Sheaf Number: E6 of 11 the engineer Whose seal appears hereon is an employee for the manufacturer for the materials described herein. Said sea; or certification is limited to the products designed and manufactured by manufacturer only.The undersigned engineer Is not the overall engineer of record for this project. I I � r I I I w i c� I cn w I u� io 1 1 ra I m 1 ro I co I m i ro I ro I ca I u+ I ra I ro I m I m I ca 1 rc 1 m 1 m I �o I v�� co 1 rc I ro I J cPa r [a I i is [,a_ t0 iA V] in W la ca is [O W [O yJ W W x W of is I Off) [a I I I M I ` I I ___-_I iq), WALL SHEETING ELEVATION "SVlC BLDG "A" cy BUILDING DTJSI t� ^rn n;Y USACY.LAP REVIEWED FOR CODE COMPLIANCE NOV 10 201'1 INTERWEST CONSULTING GROUP N 0 c ,o C C c SC a Cn mra o t N% V C kk Z N e® Z Wyl l Em LZ IN ❑ �o IN V G CI L1 o L ZN4xlLV zN El 110 F- 0 Z 0 3 0Z03 O OVOZ •c _. Z r, `3 U <�NVm O Scale., NOT TO SCALE Drown by JOE 7/14/16 Checked bg JAM 7/15/16 Project Fngtnear. SG. Jab Number: 15-8-39475-1 Sheaf Number: E6 of 11 the engineer Whose seal appears hereon is an employee for the manufacturer for the materials described herein. Said sea; or certification is limited to the products designed and manufactured by manufacturer only.The undersigned engineer Is not the overall engineer of record for this project. swc KEY PL3.N SYVA E`lAly) �— --- 12 lb i 1" r---- W8X10 W8X10 w8X18 ENDWALL ELEVATION "EWB" AT GRID LINE "1" A. �— --- 6c lb i P✓8X10 W8X10 W8X10 w8X18 ENDWALL ELEVATION "EWB" AT GRID LINE "1" A. 812.5212 \8X2.5Z14 , 8X2.5272 I SX2.5Z76 8X2.5Z16 , 8X2.5Z16 y � / I s i 8X2.5Z12 8X2.5Z1.4" 8X2.5Z12 q i 20'-0 20'-0 20'-0 I PBR WALT PANELS PANEL COVERAGE = 8'-0 60LCR TBD PANE PKG. REG'D. -PHS-1 F d Cut Fane) incTrim as required as, CUnstructic Details i dD 6c lb cb P✓8X10 W8X10 W8X10 w8X18 ENDWALL ELEVATION "EWB" AT GRID LINE "1" WALL SHEETING ELEVATION "EWB" BLDG "A" BUTTE rr)UN ,ry 11-TRUVED REVIEWED FOR CODE COMPLIANCE NOV 10 2016 INTERWEST CONSULTING GROUP T V FNS. 9EP OPENING CMP , A3LE IH8X78 W8X10 W8X10 _ F TOP GIRT TO GIFT TO BOTOM L JAMP P JAMS � L JAMB R JAMB L LMB { POTTOM I R JAMB SI. L� VERT LIFT i II JAMBS CLIS? CL 51 I CL73 CL7!v3 vN/A ! N/A SPLICE BOLT IA, E_^ 33 CONI"-. t1TY SIZE TYPEHALIENID v A 4 ,",2/ n 1; I A325 c a.N 3 (4) a X 1 3�FAJ t���r5 c E.%Mhf I C EWB PEY PLAN SWR PSR WALL PANELS PANEL COVET?AGE = 3'-0 COL06'. _ TDR PANEL PKG. RECD. = PSS- :, rield Cut Pam,O and Trim as aquired Fcr Construction 0st(Os. r 12 V, I A B B \\\\ ,�t \ / 8R2.5Z74 8X3.5Z12 \\SX.2.5Z74 ^Y 8X2.5C16 8X2.5216 8X2.5216 SX2.5Z76\, 8X2.SZ12 'a EM 20'-0 CAD V lei l�J IH8X78 W8X10 W8X10 W8X70 ENDWALL ELEVATION "EWD" AT GRID LINE "4" WALL SHEETING ELEVATION "EWD" BLDG "A„---------__ BUTT,P COUIdfY f3l�feLfid;a Df1+i15;ON REVIEWS® FOR CODE COMPLIANCE N9V 10 2016 INTERWEST CONSULTING; G; Di p SSg ff((f Q 00 a s o z czo 0M g M cCr _.p �a C'. P � xIx x xf r r•i� � O C. M � I� I> 73D1 TOMEW • HOUSTM TEAS • P.O. 801( 40538 x S NJ C, x Toil � a I ' ca*—, 0-5,0— 'o, a m Q Customer. Project Name u° Location. 10 w v a mro •c " ° v n—o a' o p•p 1 ix �I I _i m 'Zi297 CONVAIR AVE STE 2 f CHICO CA 95973 CHICO CA 95928 iu v w. I I i Is�4+ e BRIAN GINNO 1 1 a a"3 CE, 3 — \ A DrawingPrellmino V�-� Status: ❑�Na$,�'of COn3trant%On) For Construction rmi -to a+. s9 n y ck 0 y,y `� ILS ' m a a a m � a m I m m I i , rn jarCS in mia LIZ q D AT bl. i M, o -- a J U V! Q 00 a s o z czo 0M g M o< _.p z o o Mr, P � E2 _U � Q metallic building company a J U V! Dote Descrip Hon t J �� zfr rD' 47CJ ii`n n �q tt Wvk to m'.. Ji S i^ Ul Aca s � I i 00 �O Vry�j 4. O 0 0 `q 1,7 ✓Ih I Q{J Ork I r7 E n nm I By ! Ck'd Q 00 0 3oo m o -a oa=r s s ti4 n _.p oO tl P a m metallic building company 73D1 TOMEW • HOUSTM TEAS • P.O. 801( 40538 ZIP 77041 (il. 166-7838 ZIP 77240 ' ca*—, 0-5,0— 'o, a m Q Customer. Project Name u° Location. 10 w v a mro •c " ° v n—o a' o GINNO CONSTRUCTION INC MAISIE JANE'S cr^ o.omm o•a m 3 m � a-, � I i m 'Zi297 CONVAIR AVE STE 2 3764 HEGAN !IJ CHICO CA 95973 CHICO CA 95928 BRIAN GINNO a a"3 CE, 3 — \ A DrawingPrellmino V�-� Status: ❑�Na$,�'of COn3trant%On) For Construction rmi -to a+. s9 n y ck 0 y,y `� ILS ' m a a a m � a m I m m Far A royal ❑ r n•trrectiovnl ❑For Erector Installation Dote Descrip Hon t J �� zfr rD' 47CJ ii`n n �q tt Wvk to m'.. Ji S i^ Ul Aca s � I i 00 �O Vry�j 4. O 0 0 `q 1,7 ✓Ih I Q{J Ork I r7 E n nm I By ! Ck'd O'f;'WROJtCTS\xDS-`rSG7-00 FW41E .n;(15 r -3n4` /ve 01-sg t ,r, e,:/61o'o-A/Grfc/x11L Eng/75-D 947/:er0l-scuiterrez/Eh1g-A,iCrftg/x11R 7/ 6/16 15:22:57 7/ 6/16 15:22:57 CY.'RRO,?"CTS`;XDS-Vn C=-00 Fu' SE,- GDIEERAt NOTES MAIL CL_Ai ANOFS 'h^Mrd ARE A FPDXIF7,A' AND MAY VARY *LE TO CONN i1ONS (G CCTiON) V:',Mil-AL CLEARANCE DWEN5IONS ARE F,R.0 FIMSHED FLOOR Rf_FERENCE EL_vt.,Ti A w ci _ -- 5' 12 5 -Oj 4, CROSS SECTION SECTION AT FRAME LINE "3" - G" d L2�iJ TE to ii'7 ry#V 1 e'� C. U $ REVIEWED FOR CODE COMPLIANCE NOV 10 2013 INTERWEST CONSULTING GROUP a c -I,;. ,ial caL1 (FOR TOP AND BOTTOM BOLT. PAT r— CL;_N' ' ,KW' 10 _ uR 1P- ; `ONNECIs OilQ,. 1_ \� `� i✓�rl CONNECTION 36, 31 OR 3P C"1NNECTION 4B, Al OR 40 C',INECTiON 3 CONNECT...N 4X CCNIdECiCd 1E CONNEC1l0! 2E CONNECTiCS Cl NNE ION ar ] C'04 'rCTI N 4E 4 P //2 F [d TT _C CONNECTION DESIGIATION BLANK. = STANDARD (ONNECTION I j H =7 HEAVY CONFECTION 3 BOTTOM CONNECTION ',ODE BOTTOM QUANTITY OF BC -T ROWS 9 III r t NECTON DESIGNATION 9 BLANK >TANDARD CONNECTION i H HEAVY CONNECTION L OP CONNECTIONd CODE OP DUAN I I , OF BOLT ROWS CONNECTION CODE FOP,M/T I CON: rC iOIN CODE DESCRIPTION 6= "�ilS DESCRI?TIO! C CODE 1S USED D ACU t' SH -AR CONNECTIONS. SOLI ' ARE. LOCAED INSIDE THE 70P FLAIZE AT40 CONNECTION' PLATE IS RECESSED 1/8" BELOW THE TOP FLANGE. ONNECTiON PLATE LENGTH MUST8E A MINIMUPA & HALF '.HE RAFTER WEB DEP-1F! AND SHALL NOT ElCEED T9-rE RAFTE? TOTAL DEPT:`!. !C = "H;a DESCRIPTION CODE IS USED TO D; -FINE MOMENT CONNECTIONS. BOLTS ARE LOC,TED L'lIT11 I `H IEI OuISIJE 1p, OD OR FOili0 f ri_ANAND THF REMAIN)MG3 SETS ARE LOCATED NSiDE THE .OP OR 601-10111 FLANGE. F HIS OLSCi-rON COLE i4 USID I10 DrEltaE MOMENT COMNIECTIONS. DOLTS ARE LOC,TED INSIDE THE TOP OR BOTTOM FLANGE AND CONNFC120il °LAE PROJECTS 1/2" B=YOND. THE TOPDR ED' ,40N-1 I F ANv:r. I f TWIT DESCRIPTION CODE i3 USED TO U F v MOMENT CONNECTIONS. BOLTS ARE LOCITED INSIDE OP f BCT`JM FLANGE AND )INEC !-! P A,E IS RECESSED 1/E" BELOW THE ;0' CR COT',C.A FiLk4Gc. P = T',11,1 DESCRIPTIO+ C -ODE IS USED TO OFTN" SPEAR CONMTCT!ONS. BCLTS ARE LCCATD INSIDE i 'PIE 10P FLANG" ANC, CONN -C -50N PAT': S CF D 1/5 BELO"' THE TOP FLANGE CINNECON r PLATE i N 1 J l- R7 i. MIN. A ., ..flF L A.LF "HE r = FTFR VER DEPTtd AND SHALL NOT r<CEED THE g EAFTIi;? TO P_ Dk'PYN. ° 4X t7 THIS ^ OE IS DyEc TF, DLF;Nt'MOMENT CONNECTIONS. BOLTS ARE LOCATED WITH i LE'L wEIS EACH 'E Or TEE. tit )k S7 v h.AhCE M i A OU';SET PLATE OUTSIDE 'HE TOP AND FLANGE- OR COLUHN CC' PLA". L NAME -� -- CONNECTION BOLT DIMENSIONS F85_ •� i D D!AMEfER OF THE BOLT 1/2" 3/4" 7/8" CONNECTION 2B, Z OR 2P - Cr z Rb_'TION 2'F \� `� i✓�rl CONNECTION 36, 31 OR 3P C"1NNECTION 4B, Al OR 40 C',INECTiON 3 CONNECT...N 4X CCNIdECiCd 1E CONNEC1l0! 2E CONNECTiCS Cl NNE ION ar ] C'04 'rCTI N 4E 4 P //2 F [d TT _C CONNECTION DESIGIATION BLANK. = STANDARD (ONNECTION I j H =7 HEAVY CONFECTION 3 BOTTOM CONNECTION ',ODE BOTTOM QUANTITY OF BC -T ROWS 9 III r t NECTON DESIGNATION 9 BLANK >TANDARD CONNECTION i H HEAVY CONNECTION L OP CONNECTIONd CODE OP DUAN I I , OF BOLT ROWS CONNECTION CODE FOP,M/T I CON: rC iOIN CODE DESCRIPTION 6= "�ilS DESCRI?TIO! C CODE 1S USED D ACU t' SH -AR CONNECTIONS. SOLI ' ARE. LOCAED INSIDE THE 70P FLAIZE AT40 CONNECTION' PLATE IS RECESSED 1/8" BELOW THE TOP FLANGE. ONNECTiON PLATE LENGTH MUST8E A MINIMUPA & HALF '.HE RAFTER WEB DEP-1F! AND SHALL NOT ElCEED T9-rE RAFTE? TOTAL DEPT:`!. !C = "H;a DESCRIPTION CODE IS USED TO D; -FINE MOMENT CONNECTIONS. BOLTS ARE LOC,TED L'lIT11 I `H IEI OuISIJE 1p, OD OR FOili0 f ri_ANAND THF REMAIN)MG3 SETS ARE LOCATED NSiDE THE .OP OR 601-10111 FLANGE. F HIS OLSCi-rON COLE i4 USID I10 DrEltaE MOMENT COMNIECTIONS. DOLTS ARE LOC,TED INSIDE THE TOP OR BOTTOM FLANGE AND CONNFC120il °LAE PROJECTS 1/2" B=YOND. THE TOPDR ED' ,40N-1 I F ANv:r. I f TWIT DESCRIPTION CODE i3 USED TO U F v MOMENT CONNECTIONS. BOLTS ARE LOCITED INSIDE OP f BCT`JM FLANGE AND )INEC !-! P A,E IS RECESSED 1/E" BELOW THE ;0' CR COT',C.A FiLk4Gc. P = T',11,1 DESCRIPTIO+ C -ODE IS USED TO OFTN" SPEAR CONMTCT!ONS. BCLTS ARE LCCATD INSIDE i 'PIE 10P FLANG" ANC, CONN -C -50N PAT': S CF D 1/5 BELO"' THE TOP FLANGE CINNECON r PLATE i N 1 J l- R7 i. MIN. A ., ..flF L A.LF "HE r = FTFR VER DEPTtd AND SHALL NOT r<CEED THE g EAFTIi;? TO P_ Dk'PYN. ° 4X t7 THIS ^ OE IS DyEc TF, DLF;Nt'MOMENT CONNECTIONS. BOLTS ARE LOCATED WITH i LE'L wEIS EACH 'E Or TEE. tit )k S7 v h.AhCE M i A OU';SET PLATE OUTSIDE 'HE TOP AND FLANGE- OR COLUHN CC' PLA". L D (BCT DIAMETER) - D (BOLT DIAMETER HD (HOLE DIAMETER) HD (HOLE DIAMETER T�_,Cannecticn ,Coda phFBa s -` _- (See ESPdAX .n table) BottomConnectionCode_ EED(S) PF TT YT PF - — Top Connection Code t - _ S S Splice Bolt Spacing See BSMAX BSMIN and Splice Bolts BSMAX See BSMAX in Table PF TB YB Bottom Connection Code - PF 1 EED(S) or EEDK STANDARD CONNECTION DESIGNATION (CODE 4E/2E SHOWN) RAFTER COLUMN PF CONNECTION PLATE (REO'0 SPACES) 5 LENGTH IS EQUAL TO OR GREATER THAN HALF THE RAFTER WEB DEPTH E+�ODi l BOILS IFA' BE P" LD INSTALLED IN FITHER DiRECl10N CONNECTION B & P (Low Side Shown, High Side Similar) NAME DESCRIPTION FOR A325 BOLT DIMENSIONS A325 CONNECTION BOLT DIMENSIONS F85_ •� i D D!AMEfER OF THE BOLT 1/2" 3/4" 7/8" 1" 1 1/4" 1 1/2" _ HD - BOLT HOLE DIAMETER 9/16" 13/16" 15/16" 1 1/16" 1 5/16" 1 9/16" BOLT GAUGE 2 1/2" 3" 4" 3 1/2" 4" 5 1/2" G MAX. WEB THICKNESS (Max. Pg" Fillet Weld) WITHOUT WASHER i" 1 1/8" 1 7/8" 1 1/4" 1 3/8"L 1 8" MAX. WEB THICKNESS (Max. {" Fillet Weld) WITH WASHER 3/4" 7/8" 1 5/8" 7/8" 7/8" 1 7/8" HGY� HEAVY CONN, BOLT GAUGE N/A 2 1/4" 2 5/8" 3" 3 3/4" 4" NiCIRMAL BOLT SPACING 2 1/2" 3° 3 1/4" 3 1/2" 4" 4 1/2" _S_ B°MIN MINIMUM SPACING BETWEEN TOP & BOTTOM SETS OF. BOLTS 1 1/2" 2 1/4" 2 5/8" 3" 3 3/4" 1 4" MAXIMUM BOLT SPACING BETWEEN BSMAX (tIj") WHEN BSMAX = 2'-0{}" TO 4'-0 BSiA AX TOP AND BOTTOM SETS OF BOLTS .Q LOI PLATES LESS ON CCNU EC " SPLICE BOLT SPACING �1/2 1/3 BSMAX (t�") WHEN BSMAX = 4'-O�g" TO 6'-0 J THAN OR EQUAL TO 3/4" THICK (NOT TO EXCEED 2'-0) 6/4 BSMAX (±k) WHEN BSMAX = 6' -Oils TO 8'--0 l -- MINIMUM BOLT -TO -FLANGE CLEARANCE AT OUT OF NUT 1 1/2" 1 3/4" 1 7/8" 2 1/4" 2 1/2" 2 3/4" J BFCD SEE BOLT AT FLANGE DETAIL MIN!MIUM BOLT -TO -FLANGE CLEARANCE Al CONNECTION PLATE (BFCD + RNWT) PF INSIDE OF FLANGE IS INCREASED BASED ON THE YT & YB VALUE. Tr SE BOLT AT FLANGE DETAIL PF FOR CONNECTION B, F, I AND P ARE THE SAME AS USED ON CONNECTION E a NY7 NUT AND 'WASHER THICKNESS SEE BOLT AT AND .15625' FLANGE DETAIL. NUT THICKNESS IS EQUAL TO THE BOLT DIAMETER WASHER THICKNESS IS USED EVEN IF A WASHER IS NOT REQUIRED. - __ Fz RNWT RISE ON NUT AND WASHER THICKNESS U 'THICKNESS TOP FLANGE REFER TO FRAME CROSS SECTION DRAWING FOR LARGEST FLANGE THICKNESS EITHER SIDE OF THE CONNECTION. Lil TB TICKu ESS BOTTOM FLANGE YT BOLT SPACING TOP (ROUND UP TO NEXT 1/2", MIN = S) 3" + TT 3 1/2" + TT 3 3/4" + IT 4 1/2" + TT 5" + IT 5 1/2" + TT n YN BOLT SPACING BOTTOM (ROUND UP TO NEXT 1/2", MIN = S) or TB Sloped or TB Sloped or TB Sloped or TB Sloped or TB Sloped or TB Sloped U EED!S) MINIMUM SHEARED END EDGE DIMENSION 1 1/4" 1 1/4" 1 1/2" 1 3/4" 2 1/4" 2 5/3" D(RL M'NIMUM ROLLED END EDGE DIMENSION 3/4" 1 1/8" 1 1/4" 1 5/8" 2 1/4" EEDK END EDGE DIMENSION AT KNEE CONNECTION 1 3/8" 1 3/8" 1 5/8" 1 7/8" 2 3/8" 2 3/4" M-lIP1UM BOLT CLEARANCE FROM WITHOUT WASHER 7/16" 5/8- 3/4" 13'16" 1° 1 3/8" E C'?"i A FLANGE OR WEB WELD. WITH HARDENED WASHER 9/16' 3/4" 7/8" 1" 1 1/4" i 1/2" WCSP.^ MINIMUM WIDTH OF CONNECTION PLATE (Standard Connection) 5" 6" 8" 8" i0" 12" WCHM MiN!hAUM WIDTH OF CONNECTION PLATE (Heavy Connection) N/A 10" 12" 12" 16" 18" TCPAIN MINIfdUPt, THICKNESS OF CONNECTION PLATE 1/4" 3/8" 7/16" 1/2" 5/8" 1. FED(R) G FED R1 D (BCT DIAMETER) - D (BOLT DIAMETER HD (HOLE DIAMETER) HD (HOLE DIAMETER T�_,Cannecticn ,Coda phFBa s -` _- (See ESPdAX .n table) BottomConnectionCode_ EED(S) PF TT YT PF - — Top Connection Code t - _ S S Splice Bolt Spacing See BSMAX BSMIN and Splice Bolts BSMAX See BSMAX in Table PF TB YB Bottom Connection Code - PF 1 EED(S) or EEDK STANDARD CONNECTION DESIGNATION (CODE 4E/2E SHOWN) RAFTER COLUMN PF CONNECTION PLATE (REO'0 SPACES) 5 LENGTH IS EQUAL TO OR GREATER THAN HALF THE RAFTER WEB DEPTH E+�ODi l BOILS IFA' BE P" LD INSTALLED IN FITHER DiRECl10N CONNECTION B & P (Low Side Shown, High Side Similar) HEAVY CONNECTION DESIGNATION (CODE 4EH/2EH SHOWN) BOLT SS MIRED)COLUMNOR NWT RAFTER FLANGE RNWT PF BFCD, BOLT EDGE DISTANCE Fo v ruse Documentation A325 Comnection Balt Details B 4E/2EH Connection Code (See "Connection Code Format" on this drawing) Connection Location CROSS SECTION CONNECTION CODE KEY (AS SHOWN AT CONNECTIONS ON FRAME CROSS SECTION DRAWINGS EED(S) Top Connection Code_ YT S --splice Bolts _ g See 85MAX in Tcblo) T Splice Bolt Spacing See BSMAX BSM!N and BSMAX Bottom Connection Code- YB EED(S) or EEDK PLATE 2 (IF REQUIRED) BFCD BOLTS MAY BE FIELD INSTALLED IN EITHER DIRECTION BOLT AT FLANGE DETAIL (Top Flange Shown, Bottom Flange Similar) 'Flange Brace Material Schedule Pairt Mark n wn 3. L 2" x 2" x 14 Ga, F85_ •� i L2"x2"xS" F87_ ill I .at undersigned the overall eng engineer Is of engineer r record for this project. HEAVY CONNECTION DESIGNATION (CODE 4EH/2EH SHOWN) BOLT SS MIRED)COLUMNOR NWT RAFTER FLANGE RNWT PF BFCD, BOLT EDGE DISTANCE Fo v ruse Documentation A325 Comnection Balt Details B 4E/2EH Connection Code (See "Connection Code Format" on this drawing) Connection Location CROSS SECTION CONNECTION CODE KEY (AS SHOWN AT CONNECTIONS ON FRAME CROSS SECTION DRAWINGS EED(S) Top Connection Code_ YT S --splice Bolts _ g See 85MAX in Tcblo) T Splice Bolt Spacing See BSMAX BSM!N and BSMAX Bottom Connection Code- YB EED(S) or EEDK PLATE 2 (IF REQUIRED) BFCD BOLTS MAY BE FIELD INSTALLED IN EITHER DIRECTION BOLT AT FLANGE DETAIL (Top Flange Shown, Bottom Flange Similar) 'Flange Brace Material Schedule Pairt Mark Material FB4- L 2" x 2" x 14 Ga, F85_ L2"x2"x14 Ga. FB6_ L2"x2"xS" F87_ L 21' x 24" x 4° Gusset Plate 0 (At Rafter Outer Flange shown)S a ° w D (BOLT DIAMETER) 0 Moi G ED R HD (HOLE DIAMETER) all J ' �.. Z N U J EED(S) o Z< O1 Z < 0 ® ❑ U S �wS PF LL 0.7re0 o TT YT F `� PF e S Splice Bolt Spacing iN See BSMAX Z �" ❑ ❑ oN BSMIN and m BSMAX warn o U =U—V' y 0 0 ° O V O Z y ZnUQ ;O $ UzUNVa] Q Scale: NOT TO SCALE PF Drawn by. JOE 7/14/16 TB YB Checked by. JAM 7/15/16 PF Project Engineer SG S Job Number 15-B-34475-1 Sheet Number. Ell of 11 EED(S) or EEDK The engineer whose seal appears hereon is an employee th t f th Gusset Plate .or a mann ac urer or e meterlcis described herein. Said (At Rafter Inner Flange shown) seal or certification Is limited 4X CONNE(CTION DESIGNATION to the products designed and manufactured by manufacturer _ ( COEDE 4X/4X SHOWN } .at undersigned the overall eng engineer Is of engineer record for this project. BUTTE COUNTY k lllLC ' t a DIS,/IE310N ELL FOR CO DEC OM�PLIIAANCE NOV i o 2015 INTERWEST CONSULTING GROUP I FIELD SEk ICE PR C^ DUE" FS �- AUTHORI<J10N FOR CORRECTIVE INOF ?4 UNLOADING. HANDLING AND STORING MATERIALS ROOF AND WALL PANELS DAMAGE DURUNG CONSTRUCTION N MR ER TO Gs,,. YOU PROMPT SEF !CLS AND KEEP N I .Y,I.EMS TJ A 1,5„I1411M. PLEASE NORMAL ER. -CEN OPERATIONS INCLUDE HE CORRECTION OF MINOR MISFITS BY MODERATE L. - A GREAT OF TIME AND TROUBLE CAN BE SAVED AMOUNTI THE BUILDING SARIS MANUFACTURER'S WALL AND ROOF PARRS INCLUDING COLOR COATED, GALVALUME & THE c r OF WCORKMAIIDURI IN STEL ERECTION, CONSTRUCTIONFTHEMET PRACTICES, AND YAP:__c ANY °,a r c CAREFULLY CHECK 3 S:LISTWHIL M;' LCC;: CHARGES ;`J THE FM.LVNIM MAF r - r ? SING OR CUTYM AND a CrCF ELEMENTS INTO AMOUNTS OF RAVING, CHIPPING, DRIF — ARE G OARED AT THE BUILDING SNE ACCORDING TOA PRE -ARRANGED PLAN. PARTS ARE HE BUILDING GALVANIZED PROVIDE EXCELLENT SERVICE WIDELY VARIED CONOITESE ALL LING MI DURING THE CONSTRUCTION THF. METAL BUILDING CAN HANDLING METHODVC a m PACKING EAR: 3 YOUR PA•.CX NaG T. ST Milli UN! CAOiPJ='. 6T.4R,( AV' 7=�,,?5 g'.HL, r, FFJ:FE TO BE MISSING AAP? NO RE CO THE LINE THROUGH h_ USE OF' DRIFT PINS ERRORS i4H'CH CAIJPJCT BE CORRECTED BY T!E PI ATI PROPER LOCATION AND HANDLING OF COMPONENTS WILL ELIMINATE UNNECESSARY HANDLING. FULL L.I r DING & ERECTION PERSONNEL SHOULD FULLY UNDERSTAND THAT THESE PANELS ARE S � T HE PPF r ! A T THE A T APPEARANCE AND PERFORMANCE OF THE BUILDING PRIERS. t SOBNA THP Fr: 0 SERVICE eS .i 4 THE -D EDE S; .H !N THE TITLEESP BLOCK AS MENS OR WHICH REQUIRE IFI TIE CCA.4iERECTR, QUALITY QUALITY MERCHANDISE, WHICH A?ER!TS CAUTIOUS CARE IN IIAHDLING, PANEL DAMAGE UURdlNG CONSTRUCTION CAN 3E THE RESULT OF FAULTY INSTALLATION PANEL MAG DURRI ( SCO*: AS FOSSIr3':F., CAL!J-!G .: Cm,EOhE ELS_ ..0"D GLLRA P?L RROPER RESPONSE, SOMEONE IE THENERACHANCES ATOR'EF 91OULDIi`B SII^vt7?D BE 4TJRTEU IN AED;A7ELy TO THF OWNER Ay0 FABRICATOR d'f TIE EF;'eCi GR, TO NOTE: PIECE MARKS ARE STENCILED ON PRIMARY STRUCTURAL MEMBERS AT LOWER METHODS AND/OR CCARELESSNESS. ENABLE WHD?VR IS RESPONSIBLE IS 'HER TO CCRRLCT THE ERROR OR TO APPROVE THE MOST END, 1'4" FROM END. INSPECT ALL SHIPMENTS PRIOR TO RELEASING THE TIE -DOWNS UNDER NO CIRCUMSTANCES SHOULD PANELS BE HANDLED ROUGHLY. PACKAGES OF SHORI'MAWftF S- 116,5DIA;a' Y UPON D=- 42Y OF MAT6LAL, QUANT'IES ARE TO BE EFFICIENT AND iCONOM CA!_ METHOD OF COR?IECTION TO BE USED BY OTHERS. (AISC 303-10, FOR LOADSTHAT MAY HAVE SHIFTED DURING TRANSIT! SHEETS SHOULD BE LIFTED OFF THE TRUCK MITI EXTREME CARE TAKEN TO ENSURE THAT NO OVERDRIVEN FASTENHERS CAUSE INDENTATIONS OR SHALLOW POCKETS IN THE PANEL AROUND bE'- zE6 BY It t iTOxi:�i A -' 4i- QIJANP IEE F{1>7 ARE BILI - C ON TIE MMILIO SECTION 7.14) NAR G5 SECTION 7,14) IF THE Ed4J: IS TIE FAULT OF THE MANUFACTURER, DAMAGE OCCURS TO ENDS OF THE SHEETS OR TO SIDE RIBS. THE PACKAGES SHOULD BE THE FASTENER HEARD, RAIN WATER OR CONDENSES MOISTURE COMBINED WITH ATMOSPHERIC DOCILVEWT, NUISER THE V NHIALIMER NOR THE CA96:!FR i5 RESPONSTP. F FOR THE AN "AUT!OIATION FOR CORRECTIVE WORK" MUST 9E ISSUED IN WRIT114G BY THE RE^!'•FMBER, SAFETYFIRST! STORED OFF THE GROUND SUFFICIENTLY HIGH TO ALLOW AIR CIRCULATION UNDERNEATH THE POLLUTANTS (PRINCIPALLY SULFUR DIOXIDES) AND DIRT PARTICLES OM LECT IN THESE ?qT JAL ',HOP -,At .'S AOA+- i THE QUAtDTI'S 6 .AEG vrJ SHIPPING DOC'AA FT IF SUCH MANUFACNRERTO AUTINORZE THE COTCC? x!' WORK, AT A COST NOT TO EXCEED ME BLOCKING UNDER THE COLUMNS AND RAFTERS PROTECTS THE SPLICE PLATES AND THE SLAB PACKAGES. THIS AVOIDS GROUND MOISTURE & DETERS PEOPLE FROM WALKING ON THE POCKETS. THE COMBBI,NATION OF PCLLUTANTS AND WATER CREATES ACID SOLUTIONS THAT SHOR A ES ARE NOT NOTED ON SIPPING DGt JWN!S Mi.N T ' MATER -AL I ? EI :RED, MAXIMUM TATA! COST SET FOP. IN. Al TERNATIVE CORRECTIVE WORK OTHER THAN THAT FROM DAMAGE DURING THE UNLDADING PROCESS. IT ALSO FACILITATES THE PLACING OF PACKAGES. ONE END OF THE PACKAGE SHOULD ALWAYS BE ELEVATED TO ENCOURAGE WLL CAUSE CCRROSSION DAMAGE TO THE PANEL AND FASTENER. RAIN MAY WASH SOME N. THEN" u° r . q . v q GE. P. c .:E NTLF r A_O A.,KP..rN�CI)GE. P THE CARET:'•'. A.,.NT, E. THF CALMER L, Ih. laA.J... A.I"JRER. - PROPOSED n• 71' "iNiTM CLAIM" MAY BE DINECIFO BY THE MANUFAONRER IN SHE OSED LI E SLINGS OR CABLES AROUND THE MEMBERS FOR LATER LIFTING AND ALLOWS MEMBERS TO BE DRAINAGE IN CASE OF RAIN. THE MF'H EXERCISES EXTREME CAUTION DURING FABRICATING AND POLLUTANTS AWAY, BUT MOISTURE IN THE FORM OF NIGH HUMIDITY CAN KEEP THESE AREAS CLAIMS' FOR S=i?:RTaGES RRF TO BE MADE BY 'RIE CUSTOMER TO THE COMMON CARRIER. IF L.AY " ONLY � DEPARTMENT , ' AIJTHORiE CORRECTIVE WORK. O,L.: THE FIDS SERN__ OE. BOLTED TOGETHER INTO SUB—ASSEMBLIES WHILE ON THE GROUND. EXTRA CARE SHOULD SHIPPING OPERATIONS TO ENSURE THAT ALL PANEL STOCK IS KEPT DRY. HOWEVER, DUE TO WET AND CONTINUE: THE PROBLEM. OVERDRIVING THE FASTENER ALSO FORCES THE SEALING QiJANPNG RECEIVED ACCORDING TO TN THE MATERIALOTHE I D, O .4..TMEtIT ? - a AI,7HORIZE CGf [CTIVE k`rJRK. COO EC ALWAYS BE EXERCISED THE UNLOADING OPERATION PREVENT INJURIES FROM CRIMPED CONDITIONS, WATER FORMED BY OF HUMID AIR CAN BECOME WASHER FROM UNDENIT THE LEAK AT SETS POINT. PROPER SCREW HEAD CREATING c p ,AERE FGM, FEED OR T}il. GILDED "r' T: .H RP!NG. PONTIS, B:T E TIES ORDERED, THE ES" THAN THE QUANTITIES D E HANDLING THE STEEL AND TO PREVENT DAMAGE TO MATERIALS AND THE CONCRETE SLAB. TRAPPED BETWEEN STACKED SHEETS. WA'rR CAN ALSO BE TRAPPED BETWEEN THE STACKED R CAN ALSO B B , TORQUE AOJISiMENUT OF THE SCREW GUN OR FmEFERAB_Y THE USE OF A DEPTH GAUGE E u PL ARE F'. -=TOO TO COMPLETE -NE ME`FAL BU i. ACCORDING TO THE ACC RDI 1 GM O 1 - 1 ° ; r F FtrlAL CLAY,. THE "FINAL CLAM WRITING MUST B.- FORWARDED BY THE CUSTOMER TO IF WATER IS ALLOWED TO REMAIN FOR EXTENDED PERIODS IN BUNDLES OF PRIMED PARTS SHEETS WHEN EXPOSED TO RAIN. THIS MAY CAUSE DISCOLORATION CAUSED BY TRAPPED WILL ELIMINATE THEE PROBLEM OF OVERDRIVEN FASTENERS. 'a o : hANUFACNRER. LAEN E O'R;hR G^•:s1J75, CLAIM iS TCO BE MAO` ' 'tc ,N SMT -0'.n' WEN (10) DAYS OF COM?i_'ePRN OF THE CORRECTIVE WORK THE MRIZED SUCH AS GIR1S, PURLINS, ETC., 711E PIGMENT WILL FADE AND THE PAINT WILL GRADUALLY MOISTURE. THE STAIN IS USUALLY SUPERFICIAL &HAS EFFECT CN THE APPEARANCE w SOFTEN REDUCING ITS BOND TO THE STEEL. T'NEREFORE, UPON RECEIPT OF A JOB, ALL OTR..E OR SERVICE LIFE OF THE PANELS AS LONG AS II IS NOT PERMIT ED TO REMAIN ON THE IT IS EXTREMELY IMRPORTANT THAT ALL DRILL SHAVINGS FROM THE INSTALLATION OF PANEL rvr WA .ED O^nEFECT!vE?ATeR AL. — DAMAGED OR GEFECTIM MATERIA,. REGARDLESS OF DIRER AUTHORIZED B17r,'E M;'{NLrACTU?ER. BUNDLES OF PRIMED PARTS SHOULD BE STORED AT AN ANGLE TO ALLOW ANY TRAPPED PANELS. HOWEVER, MOISTURE IN CONTACT WTTN THE SURFACE OF THE PANELS OVER AN FASTENERS AND F!LLUNGS FROM THE SAW CUTTING OF PANELS BE REMOVED FROM THE IiiE DLGRkE ue I-QAMACE, MUST BE NOTED ON THE T.;HIPPINC UOCIWE473 BY T.E. CUSTOMER WAVER TO DRAIN AWAY AND PERMIT AIR CIRCULATION FOR DRYING. PUDDLES OF WATER EXTENDED PERIOD CAN SEVERELY ATTACK THE FINISH & REDUCE THE EFFECTIVE SERVICE LIFE. PANEL SURFACE. CCORROSION CAN OCCUR IN A MATTER OF HOURS WHEN THESE SHAVINGS r C rG t ^ 1 NOT AND A E - FD !P! 5<i. aN0 BY THE CARR;,R'S S-... T TIC MANUFt:; TUBER IS _ THE CUM^ MUST INCLUDE: SHOULD NOT BE ALLOWED TO COLLECT AFJU REMAIN ON COLUMNS OR RAFTERS FOR THE SEE R1-07 'DAMAGE FROM CONDENSATION OR TRAPPED WATER." OR FILUNGS ARE NCOT REMOVED AND ARE ALLOWED TO COME IPI CONTACT WITH WATER OR .kNs4 .NQ. FOR MA'ERaL OAW IVEO Xt LN,.QANPIG F P;+ f A ., Orc c - NES E A b1ERii 1. ACTUAL NUhAFft OF MAN-HOURS BY DATE OF L11RLC, tA60k USE ON CORRECTIVE WORK c SAME REASON. CONDENSED MOISNNRE. WHEN PANELS ARE PRE -DRILLED OR CUT IN THE STACK PRIOR TO r, � rI .' J„ _ 1 <r It c I INCLUDING, MIT NOT L'=LETT., v (A,,:L.v_R.., - ,>_tT MITA , U" d "-!." CcCT.ctl., &.:uJEFi°JG A r MHN, ACTUftI HW:.LY RATES HF FAY AND I t .! B ,R 2. AND CE )N TOT-._ DIRECT LAIC.. THE COAT OF SHOP PRIMER IS INTENDED TO PROTECT THE STEEL FRAMING FOR ONLY A CAUTION: � 5 S S CARE ALWAYS BE TAKEN WHEN WALKING ON PANEL.. U E SAFETY HNE, F EP,ECP.O>i ALL SHAVINGS OR FILLINGS MUST BE CLEANED FROM BOTH 510E5 OF THE PANEL _ _ T r ..7 _ CS" SEWME ANC/OR ^A' -RAGED 8-f Y'ATER W,i:;k: I5- THE POSSESSION OF OTHER T COST DRECTL 3, OTHER CASTS 04 ACNn:. D, ...LT ,:AF,u:'. SHORT PERIOD OF EXPOSURE TO ORDINARY ATMOSPHERIC CONDITIONS. THE COAT OF SHOP N r I NECESSARY! AND RILL WHEN NECESSARY. PANELS ARE SLIPPERY. WIPE DRY ANY MOISTURE OP, SURFACE c,r TO PREVENT CCRP.07_:.,h OF THE PANEL BY THESE PARTICLES IT {S IMPERATIVE THAT THE ROOF BES F T r AT LEAS. DAILY AND TO AT COMPLETER. THE FINAL 014ERTNR: V g1HERS. P„t,t.:ir{D 0:: NL., T,,, 4+4'LFJAR IHAt TC„ia•+E`' '.:., ;?( TTI.:..SVT MUST BE -,:r. ., E lIV 4. COST Cr MST..RIAL. (NO' MINtrR SUP?LIFO AU i'Y?!ZED BY 1” MANUFACNRHR TO P.L PRIMER DOES NOT PROVIDE THE UNIFORMITY OF APPEARANCE, OR THE DURABIUN AND C.. nRRO510N RESISTAF:GL OF A FIELD APPLIED FINISH COAT OF PAINT OVER A SHOP PRIMER.GREATLYF MATERIAL THAT HAS PUDDLED FROM BUNDLES STARED ON A SLOPE. DEW, FROST, 02 OTHER I 'F F THE SHOULD BE DONE PRIOR INSTALLING THE GUTTER SO THAT THE CLEANING OF THE PROOF OR INS ,_ ,p ry P .r. A,:E'� UNSQ%-KFO AT.. ORE? BY THE R 4 :PFO.:I Irl (, Ru4 Y:?'EHE PURCHASED TiCM O' IIF' THAN THE 1'AN- ACT?':E2, INf,U,CING COPIES (IE (TRIO INVOICES.SHAVINGS FORMS OF MOISTURE INCREASE THE SLI�PJR.!JESS C= ih_ PANELS. ALWAYS DEP AN LEFT O ARE NOT � DEPOSITED INTO TIE GIJ ITER AND LEFT TO CORRODE. ANY OTHER MANUFACTURER, R CT ua-c k'A. Tea FOR A tT. 4ur...T RF.. THE CU. , LAWST MAKE LI1 , f a EAC?. CIRECT.Y TO T!F. MA . F I - ::OU ate, - RILR r c e T 1 H, Ai; o'uDA it R�:_R !O A l i.?R,LL.I HE J.TOIS T.... I :LI S C c t ; .r.,,, 8• NEEP- AC 11L D"ECT „OH7 0( CO. R_CTI ft N.,n..: (SUM O' i, 2, 3 & 4}. TfE °FINAL TOUCH-UP OF THESE MINOR ABRASIONS IS THE RESPONSIBILITY OF THE END CUSTOMER. ALL ASSUME PANEL SURFACE N SLIPPERY &ACT ACCORDINGLY. NEVER WALK OR STEP ON SKYLIGHTS OR TRANSLUCENT PANELS! ION OBJECTS OOP. DEBRIS LEFT BY OF SHOUTS ALSO BE .PUT .EAE ... . CLAIM N LIABLE ORMVLI T' I! C014MOtJ CABLES IH M?IH!! ACTT. -,;H 15 NOT I.IABL rGk ANY CLAIM" MITRE EIGNEU AND CERTIFIED TRUE AND CORRECT BY THE CUSTOMER. "FIN.A °r t P R ! - - 6 - PRIMER SHOULD E_ TOUCHED UP AS REQUIRED BEFORE ERECTION SEE Rt 0 IIT -EU ERECTION THE R CF REM D ERECTION OF THE ROOF AND THE INSTALLATION OF REMOVED FROM THEE ROOF. DURING VY CIAM Y;yAT°^cvLiY Lh„JI N( B:JT NOT HATED r., LiL+' Gr,::: £S OF CCkSEC.IE�NTAI CLAIMS” ARf CREDITED TC Ti1E CUSTJMCR EY 7r£ hAl FA P'F'R IN AN AMOUNT NOT TO "SHOP PRIMED STEEL" USE WOOD BLOCKING TO ELEVATE & SLOPE THE PANELS !N A MANNER THAT WILL ALLOW TONING EQUIPMENT SUCH A S At CCNDITONING UfdI1S. ETC... e INS!,:, +:.: FLI"M TN. CU9:',RAPP'S US,: OF OAMA ED :T" DEFEC IVR MATERIALS THAT EXCEED IHELESSFR OF THE M.AXIMJM TOTAL COS' SET FiR !r !! WRITING IN THE MOISTURE TO DRAIN. WOOD BLOCKING PLACED BETWEEN BUNDLES WLL PROVIDE ADDITIONAL A c PEP.SCJNEL WALr.INOG ON THE PANELS CAN CAUSE DAMAGE. WORKMEN SHOULD STEP OR o n. r .-, Tnq p BE "_ CCT_° , 1 ... IIW< T "A.UTHC#R ZA O'! FCR CORRECTIVE W'RR!C' OR TU A!. PCNA. DIRECT COS? ()F CORRECTIVE 2 TEMPORARY SUPPORTS AIR CIRCULATION. WHEN HANDLING OR UNCRATING THE PANELS, LIFT RATHER THAN SLIDE WALK lid THE EROALD FLAT AREAS OF T1E PANEL AND AVOD STEPPING ON THE PANEL ENDS ❑ WORK. — THEM APAR"T. BURRED EDGES MAY SCRATCH THE COATED SURFACES WHEN SHEETS ARE SUD AND EDGES WHICH (CAN BE BENT BY CARELESS HANDLING. IF THIS DAMAGE IS SEVERE, THE c a i O L THING I NOT CA4 gni RF R:` tiCN r - - "-" e r TEMPORARY SUPPORTS, SUCH AS TEMPORARY GUYS, BRACES, FALSE WORK, CR!BB!N., OR OVER ONE ANOTHER. NEVER ALLOW PANELS TO BE 'WALKED ON WHILE ON.. THE GRD!;!'.). n e c EDGES MUST BE STARAIGHTENED PRIOR TO ERECTION SINCE THE APPEARANCE AHD/OR _ r I >. n PP_ c, INIPO TAF ^te _ COST OF N Cp IPMISIT (RENTAL O.. DEPRECIATION), SMALL TOOLS, OTHER EIEMENTS REQUIRED FOR THE ERECTION OPERATION WILL BE DETERMINED AND WEATHER TGHTHESSS OF THE PANEL COULD BE AFFECTED. DRAGGING ONE PANEL. ACROSS Fvr RMT MFT -%AL - ? My -FAP,T c p : 'vtS 'H. Rr}1T O RECOVER ANY `.I;KER,A,>I.. d, .tnrLA" AND : ROnT ATR NOT ,:.. .mE'-,IE?, TO CLA!rnS FURNISHED AND INSTALLED BY THE ERECTOR. THESE TEMPORARY SUPPORTS WILL SECURE ANOTHER CAN CUT OR ABRADE THE COATING CAUSING UNSIGHTLY MARKS ON THE PANEL ,v`, >' BY a, T::RTAL DC IIrvp.G IN ! XC OR iF I)k. Ra. JI.'tE.E? ' H '' DER Dfi JI.:'i373. THE STEEL FRAMING, OR ANY PARTLY ASSEMBLED STEEL FRAMING, AGAINST LOADS SURFACE 4 Sr! PM NTAROVAL T!.,. EVERY EFFORT WILL BE MADF TO SEE THAT THE. CARRIER COMPARABLE IN INTENSITY TO THOSE FOR WHICH THE STRUCTURE WAS DESIGNED, RESULTING INSOALCa AIM - IN INE EVEEVEM7 OF ER"Ory - MIS-WALR MUST PR(N•i,"'tLY MAKE A WRITTEN ARRIVES AT TH JC SIT+ NJ IN, REO sSTED DAY AND AT THE REOJESTED HOUR. FROM WIND, SE19AIC FORCES AND ERECTION OPERATIONS, BUT NOT THE LOADS RESULTING ATTEMPTS TO ERECST PANELS DURING W;NDY CONDITDNS SHOULD BE AVOIDED TO PREVENT I;- =I; - CI -AN' T CIANSA r THE KAIUFA r r :R "P.- Or DESIGN, MANLF4 TUR RMAXES NO WARRANTY AND ACCEPT,,, NO RE r ONS: !JTY FOR COSTS FROM T'HE PERFORMANCE OF WORK BY OR THE ACTS OF OTHERS, NOR SUCH UNPREDICTABLE DAMAGE AND FOR SSAFETY CONSIDERATIONS CP r ` xrT* xLL OF MATE.RcAS FABRCA VN E ;COTE.- +SSOUATED IM A SHIPMENT NOT ARRIVING AT A Rr QI rSTED TIME UNLFSS A SEPARATE LOADS AS THOSE DUE TO TORNADO, EXPLOSION OR COLLISION. (SECT. 7.9.9 AISC CODE OF DRAINAGE' CP THE ,A Cum".4, INCLUDES: P;„REEMENY H; BEEN MADE'. IN WRICING FCR k ;VARA!: -. LEO ARRIVAL TIIVt, STANDARD PRACTICE, 9TH EU.). p/% I_€AV1NG DIRT PILED) AGAINST THE EXTERIOR WALL PANELS AT THE FOUNDATION WILL CAUSE i DL '. TKN OFT NATO."',AN E T"yT Cr EK RI A! s GLUDIHG CL- 4T TES r ' '`!F. PANEL DAMAGE THIS DIRT MAY 0': WET OR AT !.EAST tWLL CONTAIN SOME MOISTURE. MUD MAY HAVE BEEN SPPLASHEO ONTO THE 'HALL DURING CONSTRUCTION. WRR951UN DAtdAGE g a IO' O T! ` N'? , A D EAI, NT O PR:+'Osv CORREC WORK N-MUDING ! ELEVATE � FSIEVAT u h tJ POOR„ MAY OCCUR WHERE THIS DIRT OR MUD CONTACTS THE PANELS. IN AREAS WHERE LIME 0 o 7 MATERIAL TO BE PURCHAS`D FROM OTHER THAN YALE w NUFAC,TURER, INCLUDING STADILIZATON OF TUNE SOIL IS REQUIRED, CORROSION DAMAGE FROM THE SOIL'S CONTENT ° ESTL`rA'RO CJATN R7RE_ AND COST, WILL BE ACCELERATTED AND MOST LIKELY BE SEVERE. ALL DIRT MUST BE REMOVED FROM 4 MMMUM TL' l- LOS7 OF PROPOSES CORM ,,:IVC" W,' -A d.<J MASiERIA 70 BE °Un;uHASED THE PANEL WALLS HAT THE COMPLETION OF THE WORK. PRE -PAINTED PANELS MAY REQUIRE "ROA'. OTHER THAN THE M h4FACTITFr?. TOUCH-UP IF 1TRE (COATING HAS SEEN DAMAGED WRING HANDLING OR ERECTION. C U° 3 THE APPEARANCE OOF THE BLDG. MAY BE AFFECTED IF DAMAGED SPOTS OR SCRATCHES ARE -0 o m to LOCATED IN HIGHLY' VISIBLE PLACES SUCH AS AROUND DOORS, WINDOWS, ETC... IF THE n z z m DAMAGE IS E%7E'NSNVE THEN REPLACEMENT OF THE ENTRE PANEL SHOULD BE CONSIDERED. 2 w_ v ® ❑ n O R1-01 R1-02 R1-03 R1-04 R1-05 TYPES OF F 3I ,7H _r DAMAGE IPOM CONDEEC" ATIC)"! OR "'RAPPED VVATER SAFETY COMMITMENT ROOF MAINTENANCE GUIDELINES rEa,v H; sR 1 u i EI IT !:> EX'1'''R?ry IMPORTANT THAT THE PANELS CE MONITORED FOR EVIDENCE OF TRAPPED T THE BUILDER/CGNTRAC70R IS RESPONSIBLE FOR APPLYING AND OBSERVING ALL PERTINENT + INSPECT ROOF FOR DAMAGE AFTER HEAVY STORMS - E QilL ALVR'o5 O SC 1 SYSTEM rr SRU h . F THE !._IAL Y Not FABRICATED O! WA't£R OR MCSTURE CO'+;D"cNSATCA, V TLE Af F.I'7VG E6? CTOtr. ,i{GH NuMIUITY CONCITONS SAFETY RULES AND OSHA STANDARDS AS APPLICABLE. m INSPECT AND RESEAL AS NECESSARY ALL ROOF CURBS AND OTHER PENETRATIONS WTH o a °_' 3� RrSI MATERIAL O: CONR cC E; BY A CO-ERFOR4 RESISTANT, COATING ARE CIF." CORROSION ,!SINE VM TEMPERAU'RE CYCLING WILL CA COVUFNSATGN BEPAIEEN THE PANELS WITHIN THE? O„ .,T TIE BUILDING HAS A COMMITMENT MANUFACTURE COMMIT' BUILDING URETHANEWYS a= 4= RA!N3TD Tl COAT OF SHOP PRIMER M ER19, THE PER-'Tr'.:r:PNCE RE;811P•EL?Fir"S OF C SH IME BUNDLE CAN OCCUR FRLQ.,tN..-Y MF.,% THE SEA COAST OR OTHER LARGE THAT CAN BE S V CQ!SPO THAT CAN BE SAFELY ERECTED, HOWEVER, THE SAFETY COMMITMENT AND JOB GET MAN •ALWAYS GET MANIJFACTIiRER APPROVAL BEFORE MAKING ANY MODIFICATIONS TO THE z 0 ❑ ❑ SS PAINT S Eu_'IvAT'?1,d HC, 13. Til COA Or SF PRIM R !S INTER ED TD PROTECT N E F WFESAT.-_:, BODIES OF W.?ER, ACTIC SITE PRACTICES OF THE ERECTOR ARE BEYOND THE CONTROL OF THE BUILDING ROOF o T3_ SEE FRAMING FC, OM A SHORT PERM, OF EXPOSURE TO ORD:MARY ATMOS'FERIC _ MANUFACTURER, m REPAINT ANY AREAS THAT ARE SUSCEPTIBLE TO RUST AS REQUIRED. 0 �i n CONDITIONS, SSD' PRIMED t Y,r,OH !S 3`OitEi? iH Ti' FIELD PEN^u:-C ERECTIONS SHOULD IF JOSS! C COERS ARF U"EO, THEY SHOULD BE TED AWAY FROM THE BUtALE" AT THE IT IS STRONGLY RECOMMENDED THAT SAFE WORKING CONDITIONS AND ACCIDENT PREVENTION m WHEN PERFORMING ROOF MAINTENANCE, ALWAYS TAKE THE F9LL04ING PRECAUTIONS ¢ n a 6E KEPT FREE OF THE GROUND AND SO POS IC NEIJ AS TO R. "INI!ZE WATER-HOOD+NG CORNERS TO LLON A'R CRCULAT.ON AROUND THE BUNDLE E. THIS WILL HELP PREVENT PRACTICES BE THE TOP PRIORITY OF ANY JOB SITE. • USE FALL PROTECTION AND OTHER SAFETY EQUIPMENT AS REQUIRED. � ¢ m 0 •o• POCKETS, DJBT. MUD AND C,NFR CONTAMNA11ON OF RE PRIMER FILM, REPAIRS OF MOISTURE EWRORATIMG FROM THE GROUND OR PCrEDiNr FLOP' FROV CONDENSING ON THE LOCAL, STATE AND FEDERAL SAFETY AND HEALTH STANDARDS, WHETHER STANDARD + DO NOT WALK ON ROOF FLASHINGS SUCH AS CUTTER, RAKE, HIP OR RIDGE z ¢ m z $ DA.!AGE 0 �'' )IEE SURFF e AND/Q' REMOVAL OF FOREIGN GN MA Lrv!::L CUE TO !MN'P.9PER PANELS. PLASIA OR OTHER IMPERMEABLE CG\%'R.5 ARE +nT R COn{3aEtlDED IMMEDIATE STATUTORY OR CUSTOMARY, SHOULD ALWAYS BE FOLLOWED TO HELP ENSURE WORKER FLASH. l 0> ¢ z In c EL ONJT..0 = -Sr - s a F O 57CzACc (. SITE C I (` ARE N L R,,,, +S-FI.ITY OF THE M ACTION IS REUIRED IF THE PANELS ARF. ROUND TO rE' ! FROM ANY CAUSE. Mt SAFETY. • DO NOT WALK ON LIGHT TRANSMITTING PANELS (I.TP'S). THEY WILL NOT E m0 a a. n .WL;FACNRER. MAN ACTCRI R ISN RFEPOF�S4M.F FOR DATE. MIR TI(? OF THE SHOP COAT OF BUNDLES MUS BE OPENED AND EACH PANEL UNSTACKED A4i! 1NOPOJCr+..Y C41ED ON BOT! SIDES. RE TETE PANELS AT A S! luhT FM;L.. W. EACH OTTER ?0 PREVENT NESTING MAKE CERTAIN ALL EMPLOYEES KNOW THE SAFEST AND MOST PRODUCTIVE WAY OF ERECTING SUPPORT A PERSON'S WEIGHT.. o o U p z c - z v+ : PRIMER G2 s.URRGS!GN THAT MAY CESuLS F••- u YPOi rr TO ATMOSF>iERIC AND -STICKING WILL ALLO.IN A? CIRCULATION AND ASSIST IN KEEPING THE PANELS DRY. IDI SEVERE T A BUILDING. EMERGENCY PROCEDURES SHOULD BE KNOWN TO ALL EMPLOYEES. DAILY , GUARD ALL LTP S AND ROOF OPENINGS. z - m S W MIR ,. a; _ EN.ThOIW Lt f. L GENOTE%ONS, PJOR THE C0':APATBIL!TY 0'?" lHE PR'?AER TO ANY F1ELT7 APPLIED CONDITIONS LRGE FANS CAN BE USED TO ClIRSULATE AIR BETVrEN THE UNSTACKED PANELS ;,., c MEETINGS HIGHLIGHTING SAFETY PROCEDURES ARE ALSO RECOMMENDED. THE U_E OF HARD HATS, RUBBER SOLE SHOES FOR ROOF WORK, PROPER EQUIPMENT FOR HANDLING MATERIAL _ STEP ONLY IN THE PANEL FLAT DIRECTLY ON OR IN CLOaE PROXIMITY TO A SUPPORTING U U N v m O COATNG. MENCFR AMASIC" TO THE SHOP COAT (INCLUDING GALVANIZING) CAUSED of AND ACCELLLR:TE DRYING. DAMAGE TO rrE PANEL C.'. ,NG G. r URS CON=E! PANELS BECOME NETS WHERE APPLICABLE, ARE RECOMMENDED. ROOF STRUCTURAL. Seale: NOT 70 SCALE NMOL"+;G, LOADING, SHIPPINGUNLOAUING AN MY',PCf AFTER PAINTING OA GALVANIZING NESTED PANELS W!TIIN TO STAY WET. DA'r'?R G`.II OCCIJR TO NE bYET AND AN', FOR PURPOSES DETERMINING UFT BUNDLE SUPPLIED BY THE FOR MFOR m INSPECT AFTER OTHER TRADES HAVE BEEN NE RCHE FCR ANY SOLVENT ROOF Drove, by JOE 7/15/16 ARE UNAYC .} :AF. (L+B;SA QE !V d.2.A) THI DA 24-43 NOUN', T+!c DFA-0CE °iCivf" AS �tG (.'?3 AND 'rOLOSAT �;d OF r'r!E PANELREFERENCE FACTURWI RT MANUFACTURER WILL EXCEED POUNDS. FOR FURTHER INFORMATION ALSO OUNDS. PILLS,THL FOR DAMAGE CAUSED BY WORKERS INCLUDING CHEMICAL CP. SOLVENT SPILLS, SCRATCHES C SURFACE. ANDS COMMONLY CALLED WET STORAGE STAIN, ZINC OXIDATION, OR "lYi{TE LMMBERS THE BILL OF MATERIALS FOR ! INDIVIDUAL MEMBER WEIGHTS OF OTHER STRUCTURAL MEMBERS. IN THE PAINT OR GALVALUME R COATING, EXCESSIVE FOOT TRAFFIC AND Checked by JAM 7/15/16 RUST'. REQUI E 4' ADDITIONAL INFORMATION IS REWIRED CONTACT THE FIELD SERVICE DEPARTMENT. S REMOVES. REMOVED MAKE SUER THAT ANY DEBRIS OR SCRAP LEFT BEHIND By THE WELDING dZWLU,t..r°st I GAL.AL.J� E i5 THE : TRAEi, NAVE FOR A. F'q TEN"R 5*CEI SI'_'T & CCdL ?v^DIJCT 1:AN^>, A CI FROM THE ROOF IMMEDIATELY. AVOID USING CUTOFF SAWS AND WvLC!FiC EWIPMEIdT OVER Protect fnglneer. SG CDA11! . OV= ^ ItPUqQti REESTANI ALUMENIHM-7I { A:LO/ RIF ALLOY M' T .E IS ICE AND SNOW REMOVAL THE ROOF. IN CASES WHERE THIS IS NOT POSSIBLE, THE ROOF MUST ADEQUATELY BALANCED TO OBTAIN TICDArFC THAT R AINS TIME CORPOrICN RESISTANCE & HEAT PROTECTED. Job Number. 15-B-39475-1 REF' FC 1V"IY L ALUMA0.& THE GALVANIC P (OIECT'DN OF ZINE THE BEST PROPERTIES EXCESSIVE ICE AND SNOW SHOULD BE REMOVED FROM ROOF IMMEDIATELY TO PREVENT OF BOH ALUMINUM & 2,,C ARE COFI N.D IN �11S C01",: "G & 01 HER A.,:,FO SERVICE LIFE FBF. BUILPN PANELS. TAMP DAMAGE 1'0 ROOF AND POSSIBLE COLLAPSE. DO NOT USE METAL TOOLS TO REMOVE THE ICE OR SNOW AS THIS CAN DAMAGE THE PAINT AND/OR GALVALUME COATINGS. ALSO, BE FOOT TRAFFIC KEEP FOOT TRAFFIC TO A MINIMUM. HEAVY FOOT TRAFFIC CAN CAUSE PONDING ON LOW Sheet Number. RT of 21 CAREM AROUND PLUMBING PIPES AND FLASHINGS PITCHED ROOFS. THIS IS PARTICULARLY TRUE JUST UPSLOPE FROM THE EAVE AND AT The PREPSUNTES) USING CAu 4A dM. S -.=i AS A SL3SC,, r Prr P1!,J,I5 ``T..:L. IS QMN A ATI IONAL. r- �,+, (' » / Imo,-T� \ BE EXTREMELY CAREFUL IF YOUR ROOF HAS UGHT TRANSMITTING PANELS. THESE PANELS WILL NOT SUPPORT A PERSON'S WEIGHT AND WILL BE DIFFICULT OR IMPOSSIBLE TO SEE IF ENDLAPS ALWAYS WALK III TINE FLAT OF THE PANEL NEAR A SUPPORTING ROOF !_ OFF STRUCTURAL DO NOT WALK ON TRIM OR IN CUTTERS. ON BARE GALVC,I LIME HD" engineer whose seal a appears hereon is an employee PFee . L u OR a r 1 STHEo- NIST INHIBITOR PRIMER THIS ,RM !' COAT Fn:,7HCH IF :'LEASES Unc,7.39Ai ` / �-'1 I THEY ARE COVERED WITH CE AND SNOW. SEE 2002 MBMA LOW-RISE BUILDING SYSTEMS EXCESSIVE FOOT TRAFFIC MAY CAUSE. BLACK RI ENISH MARKS. IF REGULAR FOOT TRAFFIC for the manufacturer for the materials described herein. Sold RE. -S IANGE THP E 04-.T, A ARE APPULD 0 INE LXIE'IOR - "'FACE OF THE PANELS f� - MANUAL APPENDIX A9 FOR DETAILS ON SNOW REMOVAL PROCEDURES. THESE PROCEDURES IS PLANNED FOR A ROOF, PROVISIONS SHOULD BE MADE FOP, A PROPERLY DESIGNED AND seal or certification is limited AND WE A A.- COATI '±F T -E' ^'? Y FuR ?^ T �' U'T i rPL4ED -- ',HE OPPOSITE I SHOULD COMMENCE WHEN HALF OF THE DESIGN ROOF SNOW LOAD SHOWN ON THIS SHEET IS INSTALLED ROOF WALKWAY SYSTEM. IN ORDER TO LIMB ACCESS TO THE ROOF, ROOF to the products designed and P' 9 S,DF. GA'VALUME 'tD PRt PFI TED STEEL r SI t!LENT S€4VIu?- FOR MANY YEAS CONCERNING THEIR AIR CI CU.A110N REALIZED. HATCHES OR ACCESS LADDERS SHOULD BE LOCKED AT ALL TIMES A SIGN SHOULD BE undered by F 11-W PULES CAF AND M N Nt ICE APF O,SERV 6 AL OF THESE POSTED AT THE POINT OF ACCESS, STATING THAT ONLY AUTHORIZED PERSONNEL ARE only J e anly.lhe undersigned engineer Is ed engineer RNtS-"ES ARE EQUALLY SLa,P.T TO',MMAGE AND CORHS KV WN tH CASE IS NOT PREIMDED, DEBRIS REMOVAL ALLOWED ONTO THE ROOF. IN ADDITION, A LOG BOOK SHOULD BE KEPT OF ALL V'.SITS TO not the overall engineer of +- - .(. r. € aaT ar SOFTENING rI s r -, ;.,; r A „OFTENS IF THE PAIN:- OCCUR WICH PTE r 4 "PJ UNDER WD. STORAGE ANY FOREIGN DEBRIS SUCH AS SAWDUST, DIRT, LEAVES, ANIMAL DROPPINGS, ETC. WILL CAUSE THE ROOF AND THE REASON FOR SUCH VISITS. record for this project. P J r TtIN IT RN a U4:€AI. P A. :TE sP?C- PAINT - T , cr OF AIL BARE S ND THE DURABILITY OF11-1,1ECA"TELEFINISHLY SURFY DECREASED. CORROSION OF THE ROOF, GUTTERS, TRIM, ETC. IF LEFT ON BUILDING SURFACE FOR A LONG GALVANIZED ,. TO SURFACE 0%1 GALVANIZED FED GALVALUME PANELS REI(? MORE ON SENSE ENOUGH TME, THE ROOF SHOULD PERIODICALLY INSPECTED FOR SUCH CONDITIONS AND IF DISSIMILAR METALS HAS :0 SE REMOVE i C MARC,' r a xar. :;e .ro; r¢•nT ,R FROWNr A,.. s Ma.".T.,.. FR"A BARE L.s. JET,;_. r., .:UV=, TACK TE AXP`..RE PRM (EGTON OF PAINT, ZINC CO TE ALUMS COATED OR GAI.VAWA!L PANELS D I FOUND, THEY SHOULD BE RECTFTED IN A MANNER CONSISTENT WITH THESE ROOF NEVER ALLOW YOUR ROOF TO ACME IN CONTACT WITH, OR WRIER RUNOFF FROM, ANY Ronald W. Bennett, P.E. 504'A I IT A S(?-L'eVT•fRl Ft LC7?VE. RIGHTY RUB Y,Tn A CLE;4 iJ1 ASG R?NSE 'F' -H WATER. DO NOT PA NWA l/NDER hORMI. EXPO'.LJRE PERM A ZINC OR ALUF".IkIM EXU;:' FILM ON ?HEIR SURPAEE U!bE NM MAINTENANCE GUIDELINES NEVER ALLOW TREATED LUMBER OR CONCRETE/MORTAR/GROUT TO DISSIMILAR METAL INCLUDING BUT NOT LIMITED TO: COPPER, LEAD OR GRAPHITE. T'.!S Califomia P.E. C050732 FU.. WORE THAN PzGIARFu -0 !Lh OIr S i D F. NO FIR'' I I W`_L REMOVE ALL SMUDGE Ns , u,• -AT,, , ALf.OWiSL A ngJrvOX OATEN P 0 ESS ..PLEBES, F �NC'I" TO OCCUR THAT 'P!.Gg!TS COME IN CONTACT WITH ROOF PANELS, ESPECIALLY GALVALUME®, FOR EXTENDED PERIODS INCLUDES COPPER AND ARSENIC SALTS USED IN TREATED COMBER, CALCIUM USED IN -' I }R';S R:!ACI RUST S' N:: SOFT SISUD t- i ,I,i BLth4H t! PROVEN TO 6E OM`;r!A7 CRVT. L!LH7 Y PUS WIT+ A MTh ND 4 N- WITY IVATER DO NOT I RTHE' CCROSON, F NESTED BUN LES COPS:ANT CIN7ACT OF TT PANELS WTH' OF TIME. CON CRETE, MORTAR AND GROUT. � {g SSV l� l T S1 , � TE Gi�� rr - 2' T r c a r T P II RUS MORS ! REQUIR_ 10 REN £ TAF JO :' d T ARL CMA. FTEIY RPh. VE RUST CONDENSED D 0 IR.APPED WATER PREVENTS IS WEADI[RiNG PROCF`S. 1 e"a PERIODIC INSPECTION p'� �11A PI P,,�,��i� Ti'.'rS, TI !,LION P SCRATCH"S 'F' P ?hr (MIT N CARE dE A ), CLEAN AREA TO BE HIGH-STRENGTH BOLTS SHALL BE PERIODICALLY INSPECTED FOR TIGHTNESS, pLI•5 ��IL^./��'N'l� 4-Nd'1W By PAINTED AIT MILD DE^-� f 1? WN `L THOROUGHLY AND ?Y "ING A MALL ARTS 'S BR -.?H. H6HT : ,NI -III(-' MIN161AL AM O � r?;.OR ;ATCHED HOU; H UP PAFN RAPID VIIDATI PN OF THE ZINC OR ZRIC ALJL'.!IUM COATRS CAN NOW OCCUR AND MAY LEAD TO 'RED RUS" IN A SHORT TIME, IF DiSCOIGRATON 0, STAINS ARE MINOR, A HNSEHOLD PORCELAIN CLEANER 'iE. TYPE USED GN PORE=Lf IN S..I ,S AID BA7HT135 ASAP BE U9,.4D TC REMOVE TUGS 4 NER O LAIN St ;'. ALL PARTICULARLY IN CRANE BUILDINGS AND AFTER ANY SEISMIC ACTIVITY OR WIND ACTIVITY. THE CRANE MANUFACTURER WLL SPECIFY A MINIMUM PERIOD BUT IT SHOULD NOT EXCEED 2 �� 'bONJ 4�:•'►° ! RE JItFS TO F..L/GO$4 a3 4CRATCt1 CONT C'I 3JILi C M ! A ACTLP,ER FOR THE BRE BRUSHING CRU (AAI :ILLS BE AVOIDED SINCE YEARS. G AS_S:ANCF h 9 ORRER! /PUR,.4a:G t.:.:..'} Lr PANT AS„LDFD- SCRATCHING R REMOVAL OF THE COATING COULD OCCUR, PAIELS WTH SIGNIFICANT DAMAGE S'HOLD BE REPLACED BY THE BUYER BEFORE ERECT!%!, DRAINAGE m KEEP ROOF FREE OF DEBRIS AND KEEP DEBRIS OUT OF GUTTER TO ALLOW WATER TO 0F.ESS[ '�+� QUICKLY DRAIN FROM ROOF. m NOT USE WOOD BLOCKING TO HOLD EQUIPMENT OFF OF PANEL SEAMS. THIS BLOCKS Cf € THE RDW OF WATER AND P AC MOISTURE. E + DO NOT ALLOW ROOFTOP AC UNITSDSM OR EVAPORATIVE COOLERS TO DRAIN ONTO THE ROOF. m ANYTHING THAT TRAPS OR HOLDS MOISTURE ON A ROOF WILL CAUSE PREMATURE P-�It / /� REVIEWED •` E I E V V E D CORROS1DN, FOR 1 CODE COMPUANC No.0050732rn C,,P” R1-06 R1-07 R1-08 R1-09 NOV 10 201. - ! `Nw s3AXj R [ y{Il"II.F�pp��^ �af`r'r A INT ERWES_TCl 27dI b6Y3 Coni -_. - —_ Cf 11 TINt� ,-. _—.,,Iry VY\'L. utl BUIlLDINC3 ANCHN q LG \ a v TRANSIT �i. 1. To >',m!,e trot t.e. founCr+toll ie square, rrieasure diagonal dimens'ons to be sue they are of asu,i lenge` ANCHOR POO SETTING T01_11RANSEi" 2. To un rn.nn that the faiind,ltin Is's-v e up a transit or level and use a I level .:d to abtan the aeGctlai ,.a .!77 columns. g 3. Carefullv chec!< the ioccilcn of all anchor rods against the Anchor Red Sett;ng Flan eurnl Fed by the +roll' urar. All dimensliOns must be iaerti .1; to ae u e a pre.% Y start-up. AISC CODE OF s T AN )A' lira PRACTICE. TOLERANCES FOR SETTINR:l; ANCHOR RODS t---------'- 7 51 Anchor rods, foun�otn.n bolts ODA o,r. r errlbeddPd items shall be sat by the I ut Is -s do :,nates epi antutieret for corstrtiction u1 nccOrc'•ance with embedment ! ! ,.,A hove bp"n approved by the co-iner c designated representatives for =nand CnnstrUC ran T^re va in i rn In 'ce at+ n of tne.,e Items ficn the dimenslols k hclvn in the embedment drowine oes fcllOws: S (a) Iha 1"•.`•FIatIL?P in dIr'tenIJrY t}a:y:(?n the Ceni5YS 4f any two snore;" 1'ed"> within on arl:;hor--reit grouP lincil be t quo' to or leas titan i /8 in. [3 moil]. "-i lho variation in dimension b=cw n the center. o{ odiaCarl onchor--red y3 tfrc,p shat! be rauo{ to or less than 1/4 in. 1`6 rnpi). y (ci The v.rrlaiion In elevation .t -i,le tops of an^hOr rods shall be equal to a ! cthcn rt., or rr , 112 in.I 1,r MITI. {a;our filar the '[he acwurn Icted va n. in d� ns on between center rF the nnrhor--rid, �rran 1 throuyt mu pie urc,hor rod gra p i all be I l r .q hal `a or l _ s than 1/4 In Per 'Gr ft [< mm ptx 1n+,00 mral C_!t not to Rx r a laid c rr5 a �l I a'v r et cn d mcn� x am _i `ur of any onchor-rod group to the co.u-r 1 hire throtjgh their gm p sh,111 be equci to or less than 1/4 in. (6 Drum.. The tc!erarec„ s tfwt or, ea iled n (L), (r) and ca) shall apply to offset dimension; shown in the s r ue's c eegr dirnwings, me surer uarAel and perp. nd cular to the r c t column lir for incliVinuairn un<;s 'that ere shown in the structural design •+row. V is cis offs -t from Column L ,e.. i.5.2. t!n°ess Otherwise specified i the convoct documi1 > anciv)r rods shall be sit i w th zher lor. ituair l c' 1 perpen Iiia tc the theorc .co! bearing surface. I ; j t 5 Emb died i.: m and carts 'r rateral that ore part of the, work of other I ! trades; but 'hat v4'3l receive true urr leen sh ii be located and ser by the ovmer': to;gnoted rept sentrrnn f i ce tru fio,,, m accordance with m•, cr,OVEd enibedsnent driciuing. fie 1 rict,on in iocotor of these tem shall he Brit to a magnitude. that is consistent with t`ie tolerances that are specified in Section 7.13 for the erection of the structural steel I 675.4. ,All work per-arme3 by the oar-rs dsignoted representative for construction I snall be cor^rleted so as hat to decy c, Inlerforn,with the work of the fabricator and the erector. The 0.Cers designated .reC es htntive for Construction Sha!! CODOU, E a survey of the as bolt lorallons of anchor ,ads, foundation boats and other k embedded items, and shall verify that n; items covered 'i' Section 7.5 meet. the !! car es +onding tolerances. When cc ,,r oction is necessary, the owner's designate! I representative for < nsiruc°ion s"al os4.air the g.idan_e and approval of the owner dcaigroted represe+toUve for alesC it is extremely imp 'ant that anchor bclfol be placed accurately in accordance with ! the Anchor Rod Setting elan. All anchor rods should be held in place with a terllplote or similar rrieans, so that they will .remain plumb and in correct location during plac:nq, of the concrete. A fn r, check hw. a be made after the completiol j of the concrete wa& and I ro to '; + strel Installation, Iris wilt allow any necessary corrections to be mare befc e fti Costly installation labor and equipmen orf v.,_ STEL LINE STFEEIL. LINE TEar"I ATE — STAKE Stiff €INC -' NNUL H� H f f FCk I BOA D D TC.4PL.Alr PKARD ANCHOR PoD9 �._ A A (.alp„-�' !r j�. ! ` ��._• I PRC R, E`n, OF ANCHOR R01"r, G” l Kms, B L VEft OR ANICHaR RL PLAN.fl'ii�Chl,,IG NO= -CH SHOWN ti `1,,..--.�.•--^1 MAY NOT' ° F_-QUI7 D DNEN`'!gidS A, B ANDC AS GIVEN u ArcHO Fim PLAN; ON ANCHOI BOLT PLAN l Ern cin Specified Column Centerline Bottom of Base Plate tt/2." t13mm) IILJ *Variation in Elevation to the Teos of Anchor Rods BASE QLAT;ANO ANCHOR ROOTOLERANCES FIELD TOLERANCES COLUMN ALIGNMENT TOLERANCES %1FZZANINE REAM HEIGHT TOLERANCE SIDEWALL 1r + 1 1 I O 500 500 i I I I I r In z 500 500 � \� 5W � 1 -� s1=FWALL 1 -- FLAN VILV. Ai ICNPd'.EN TTOLERANCE FOR MEML3ERS WITH FIELD SPLICES p ROOF CURBS ROOF JACK INSTALLATION (When not Supplied by Building Manufacturer) a Curb Base Length Panel PrnD!a s„ -""Vv ie Down UP vars % 4 I �Mln12" Mln. Hill 6" �.i w I I l c a �' Max Roof Pane. • eaye�' to r /D073Sf. ILirorrect .MO ;oaf Panel � b ' m Install Pipe in cantor to allow base of rubber roof } q to lay flat on panel. Cannot encompass more than 755 755% y- Purlin Line of pend. Indicates Roof Panel Support location ® Indicates Curb Base Support location Profile Penal Rib Floating Panel Support ❑ Da not use galvanized roof jacks, lemd hats or other residential grade roof jacks. These roof jacks do not have 20 -year serv✓lce life and, in the case of lead hats, will cause a galvanic corrosion of the roof panels.. < a.v ❑Use EPDM rubber roof jacks with or integral aluminum band bonded Into the perimeter of 0, Up Lift plate t (If Required) curb Base the base. For high empercture applidcations (200-400 degrees Fahrenheit) use silicone w N n:hber roof jacks. Retrofit rubber rooef jacks are available for applications in which the to o ! of the pipe is inaccessible, eliminatinog the possibility of sliding the roof jack over the top cix of the pipe. ,ro ¢ Section : "A" ❑ Do not use tube caulk/silicone to asset roof jack to the roof panels. Use only tape sealon (Insulation when specifled) as supplied by Metal Bldg Monufactcrrer. Fasten the roof jack to the roof panels with 1/4"-14 x 7/8" Lap 'Tek Stitch Screews at 1" on center around base of roof jack. The curb details shown illustrate the building manufacturers recommended curb I Q Roll down the top of the roof jack rand apply tape sealant continuously around the C •EI. style and installation method. It is the erector / installers responsibility to exposed portion of the pipe. Roll the: top of the roof jack back over the tape sealant. G a provide the proper curb style and install them in accordance with the Apply the stainless steel clamp over top of roof jack and firmly tighten to form a secure 3 4 0 procedures established by these details. Failure by the erector / installer to compression seal follow these recommendations may result in the curbs damaging the roofs stem El Do riot install a pipe through the stranding seam of the roof panel. Keep pipe penetration mPi $ G� y q g y' in center of panel to allow the base of the rubber roof jack to seal to the pan of the es y or excluded from warranties. All roof curbs to be: panel oI If a pipe must be installed through ca panel seam, or if the pipe diameter is so large to eiI j �l w 1. .080 Aluminum or 18ga. Stainless (No Golvalume/No Galvanized) black the flow of water down the roaOf panel, yo must install a "pipe curb" into the roof d an m 1 2. Panel rib to rib installation (No flat skirt or lay -over Curbs) and then sea! the pipe curb with rubber roof jack. For pipes in which tap cannot be hza° 3. Installed over low end / under high end application. for water flow at accessed, a two-piece pipe curb is covaileble. � E�^ z � i v panel splice ❑ In Northern climates, protect a':I pipe! penetrations from moving ice or snow with a snow w o 4. Up lift prevention for clip applied roof systems are required if: P PP P g '�ma2 retention system immediately up slope from the pipe. r ° a n z -v a. Wind load exceeds 110 mph or ?k a- �" y b. Curb base crosses a purlin CA 5. Supported on (4) four side by primary or secondary framing 6. Max ROOF JACK INSTALLATION �� v Single Curb weight Recommend = 1500# (Not bye Metal Bldg Manufacturer) ** gad Panel profile varies - SUGGESTED METHOD OF PURLIN ATTACHMENT Roof Jack «« zo N FOR BLDG ACCESSORIES) -- _ Roll Top Down p n .� "" Stainless Steei Clamp l • U uy n ¢ m j. 1/4-14 x 7/8" Lap Tek 'Ku- m z o Ste 1 I 1 S.D. w/washer at i° D.C. L• o> ¢? y ,« Td -bead Tape Sealant _000Z •3 h:'W504 U EMIR O PURLIN ANGLE (W/ 2 Scale: NOT TO SCALE SELF-DP•ILLERS" ANGLE** Drawn by JOE 7/15/16 HANGER ROD" SPRINKLER HANGER Checked by. JAM 7/15/16 PIPE ROD «b Project £ngouser. SG pd� Apply Tri -Bead Tape Sealant Continuously Job Number. 15-B-39475-1 / «« StolNess Steel Clamp %/ A around Pipe SUGGESTED METHODS Sheet Number: R2 of 21 + t +* f�/ Roof Jack ;f ** (Not by Metal Bldg Manufacturer) 7� � \ The engineer whose seal 7 hereon is an employee ek as ears h 1 4-14 x 7 8" La T Ste 2 P P r / / P hanger rod. Thisr the e purlin to catch htln )or the manufacturer An angle is self -tapped to the web of th p g S.D.sDwfWasner at 1° O.C.oc. method does not preclude other forms of attachment to the purlin web.lj(' t materials described herein. Sold The total hanger load shall not exceed the design collateral load for the building. l m' seal or certification is limited A sample calculation is shown below:///f ® ® \ Td -Bead Tape Sealant to the products designed and 5' (purlin spacing) x 5' (hanger spacing) x 6 psf (collateral load) = 150 lbs. \ \ r1w5D4 manufactured by manufacturer nnly.Tha undersigned engineer is See cover sheet for design collateral load for this building. not the overall engineer of Note: If this building is designed for 0 psf collateral load, then adding any record for this project. suspended system (i.e. duct work, piping, lights, ceilings, etc.) will correspondingly reduce the design live load. -6' CaliforniaYF. Bennett, P.E. ,,. CaliforP.E. C050732 DO NOT INSTALL HANGER ROD IN FLANGE OF PURLIN fHE INCORRECT WAYS ROD. ANGLE OR CHAIN CIDP DO NOT INSTALL PURLIN CLIPS OF ANY KIND ON FLANGE OF THE PURLIN AS SHOWN xa Stainless Steel Clor Step 3 Tri-B.lcd Tape HW504 BUITEE COUNTY BUILDING 'E"''J,S;U I fit' ' yfp \- .Tri -Bead Tape Sealant HW504 \ Roof Jack •s AA 1/4-14 x 7/8° Lap Tek D. w/Washer at 1" O.C. ��' NOTE: Roll roof jack up over Tr' -Bead Tape Sealmt and secure the clamp. FOR REVIEW OUE COMPLIANCE NOV 10 2016 INTEREST CONSCONSULTINGLTG GROUP H/500 'D'HT (}) TOLERANCE 10' 1/4' 17 6,/15' 15' 3/8" 201 1/2° 25' 5/8" 'O. 45• 1 1/16" 60• 1 7/16° COLUMN ALIGNMENT TOLERANCES %1FZZANINE REAM HEIGHT TOLERANCE SIDEWALL 1r + 1 1 I O 500 500 i I I I I r In z 500 500 � \� 5W � 1 -� s1=FWALL 1 -- FLAN VILV. Ai ICNPd'.EN TTOLERANCE FOR MEML3ERS WITH FIELD SPLICES p ROOF CURBS ROOF JACK INSTALLATION (When not Supplied by Building Manufacturer) a Curb Base Length Panel PrnD!a s„ -""Vv ie Down UP vars % 4 I �Mln12" Mln. Hill 6" �.i w I I l c a �' Max Roof Pane. • eaye�' to r /D073Sf. ILirorrect .MO ;oaf Panel � b ' m Install Pipe in cantor to allow base of rubber roof } q to lay flat on panel. Cannot encompass more than 755 755% y- Purlin Line of pend. Indicates Roof Panel Support location ® Indicates Curb Base Support location Profile Penal Rib Floating Panel Support ❑ Da not use galvanized roof jacks, lemd hats or other residential grade roof jacks. These roof jacks do not have 20 -year serv✓lce life and, in the case of lead hats, will cause a galvanic corrosion of the roof panels.. < a.v ❑Use EPDM rubber roof jacks with or integral aluminum band bonded Into the perimeter of 0, Up Lift plate t (If Required) curb Base the base. For high empercture applidcations (200-400 degrees Fahrenheit) use silicone w N n:hber roof jacks. Retrofit rubber rooef jacks are available for applications in which the to o ! of the pipe is inaccessible, eliminatinog the possibility of sliding the roof jack over the top cix of the pipe. ,ro ¢ Section : "A" ❑ Do not use tube caulk/silicone to asset roof jack to the roof panels. Use only tape sealon (Insulation when specifled) as supplied by Metal Bldg Monufactcrrer. Fasten the roof jack to the roof panels with 1/4"-14 x 7/8" Lap 'Tek Stitch Screews at 1" on center around base of roof jack. The curb details shown illustrate the building manufacturers recommended curb I Q Roll down the top of the roof jack rand apply tape sealant continuously around the C •EI. style and installation method. It is the erector / installers responsibility to exposed portion of the pipe. Roll the: top of the roof jack back over the tape sealant. G a provide the proper curb style and install them in accordance with the Apply the stainless steel clamp over top of roof jack and firmly tighten to form a secure 3 4 0 procedures established by these details. Failure by the erector / installer to compression seal follow these recommendations may result in the curbs damaging the roofs stem El Do riot install a pipe through the stranding seam of the roof panel. Keep pipe penetration mPi $ G� y q g y' in center of panel to allow the base of the rubber roof jack to seal to the pan of the es y or excluded from warranties. All roof curbs to be: panel oI If a pipe must be installed through ca panel seam, or if the pipe diameter is so large to eiI j �l w 1. .080 Aluminum or 18ga. Stainless (No Golvalume/No Galvanized) black the flow of water down the roaOf panel, yo must install a "pipe curb" into the roof d an m 1 2. Panel rib to rib installation (No flat skirt or lay -over Curbs) and then sea! the pipe curb with rubber roof jack. For pipes in which tap cannot be hza° 3. Installed over low end / under high end application. for water flow at accessed, a two-piece pipe curb is covaileble. � E�^ z � i v panel splice ❑ In Northern climates, protect a':I pipe! penetrations from moving ice or snow with a snow w o 4. Up lift prevention for clip applied roof systems are required if: P PP P g '�ma2 retention system immediately up slope from the pipe. r ° a n z -v a. Wind load exceeds 110 mph or ?k a- �" y b. Curb base crosses a purlin CA 5. Supported on (4) four side by primary or secondary framing 6. Max ROOF JACK INSTALLATION �� v Single Curb weight Recommend = 1500# (Not bye Metal Bldg Manufacturer) ** gad Panel profile varies - SUGGESTED METHOD OF PURLIN ATTACHMENT Roof Jack «« zo N FOR BLDG ACCESSORIES) -- _ Roll Top Down p n .� "" Stainless Steei Clamp l • U uy n ¢ m j. 1/4-14 x 7/8" Lap Tek 'Ku- m z o Ste 1 I 1 S.D. w/washer at i° D.C. L• o> ¢? y ,« Td -bead Tape Sealant _000Z •3 h:'W504 U EMIR O PURLIN ANGLE (W/ 2 Scale: NOT TO SCALE SELF-DP•ILLERS" ANGLE** Drawn by JOE 7/15/16 HANGER ROD" SPRINKLER HANGER Checked by. JAM 7/15/16 PIPE ROD «b Project £ngouser. SG pd� Apply Tri -Bead Tape Sealant Continuously Job Number. 15-B-39475-1 / «« StolNess Steel Clamp %/ A around Pipe SUGGESTED METHODS Sheet Number: R2 of 21 + t +* f�/ Roof Jack ;f ** (Not by Metal Bldg Manufacturer) 7� � \ The engineer whose seal 7 hereon is an employee ek as ears h 1 4-14 x 7 8" La T Ste 2 P P r / / P hanger rod. Thisr the e purlin to catch htln )or the manufacturer An angle is self -tapped to the web of th p g S.D.sDwfWasner at 1° O.C.oc. method does not preclude other forms of attachment to the purlin web.lj(' t materials described herein. Sold The total hanger load shall not exceed the design collateral load for the building. l m' seal or certification is limited A sample calculation is shown below:///f ® ® \ Td -Bead Tape Sealant to the products designed and 5' (purlin spacing) x 5' (hanger spacing) x 6 psf (collateral load) = 150 lbs. \ \ r1w5D4 manufactured by manufacturer nnly.Tha undersigned engineer is See cover sheet for design collateral load for this building. not the overall engineer of Note: If this building is designed for 0 psf collateral load, then adding any record for this project. suspended system (i.e. duct work, piping, lights, ceilings, etc.) will correspondingly reduce the design live load. -6' CaliforniaYF. Bennett, P.E. ,,. CaliforP.E. C050732 DO NOT INSTALL HANGER ROD IN FLANGE OF PURLIN fHE INCORRECT WAYS ROD. ANGLE OR CHAIN CIDP DO NOT INSTALL PURLIN CLIPS OF ANY KIND ON FLANGE OF THE PURLIN AS SHOWN xa Stainless Steel Clor Step 3 Tri-B.lcd Tape HW504 BUITEE COUNTY BUILDING 'E"''J,S;U I fit' ' yfp \- .Tri -Bead Tape Sealant HW504 \ Roof Jack •s AA 1/4-14 x 7/8° Lap Tek D. w/Washer at 1" O.C. ��' NOTE: Roll roof jack up over Tr' -Bead Tape Sealmt and secure the clamp. FOR REVIEW OUE COMPLIANCE NOV 10 2016 INTEREST CONSCONSULTINGLTG GROUP PRF: -ERECTION iNOTES: Pie following retes, arocedures and suggozted recortrnendatlons ore important pa of the prs--erect'=.on process. 1.) Prior to the time the erectirn cre.y arrives, a responsible person should check the job site for foundation readiness, square, and accuracy and And?or Rod sire and locatie;. i1he dfawing Shawn below Ont trte! G me.L:ad which may be used i0 Check I faundoio and bar- squc.e. LS BE Measure c'c nq ad cent aides of four idcdk n using a pair of dimensions shown. If ,he ciagonc' -tvioe-i is as riot:,d, the corner is square. Dicgoncl r, _auure^ ;.- botwl"n oiray.cI:e An, - "ads w !l indicots if these bolts are suet square:. ? u:"tier unloo,11ins the huddinc tc,efinly hack off each it m from the packing .t. Bundl es and ,)7xes will have a : st a .ac'.ad I7 .Icofing the Contents. 3.) Unlood and lo- iu the hi-11cfl,ic _clump,- or tie foundation. 4.1 Unload the rafters onto fh jq,roiHari "kat they con ba erected from e1=ache e" end ,of t4< bu icing r:,u wish to start. Your crane will move from one end of the butchrig t-) .'-,e other 0:1, ,;DrAlng ccrur is ord hangirr.g rafters 5.) Layout the gats and purlins on du mciio or wood blocking around the fourilatlan as near as possible to whore they will be instaiecL &.) Unload and place trim crates out of the war, since these y -0L be the last required. 7.) Unload and place panels and irsulation out of the way. 1-10'2: In extrasr,ely cold conditions, the viny facing on insulation will become britt!-, requiring very. careful hanr§iing. 8. Avoid lifting ,are stocks with cables, chains or Other devices which could doonage the panel. Upon unloading, am• ovary nnorning thereafter, inspect he pane. bmndres for moisture bete -en Ire p -^cos, ,his is esp dally'important with aa!valume o, galvanized panels. The pans' finish must be protected at rA times Leto.,- ons' during erection to preserve the appearance and function.. or the panels. 9.) Aq hardware boxes should be pratectec from theft and moisture, especially items such as tube caulking and iorli is. Store, mostic oway from heat. LAYOUT OF, 21 CGlOPONE'.N T r!-.FUn L.1I ¢r:7EwS ie z� Cf ^�® ftiMP� �� i --�.tr . 1. '?it's, E.ove. {ruts and PUr!ins 2. End Lrorm's and Lndpost 3. +lain Frames 4. Cline, Polls. Scraws, ETC. 5. End -vii -di Si, ts i.] Layou'.: primary and secondary framing around the s'sab as shown. '<4 Place components and crates on the slat, or on wood blocking to prevent contact with the ground. 3.) Block ere end of cr mpennemts b ,her than other end to ailove drainage of rair 4.) Leave one end of the build;r.g open for erection equipment access. S.) Construct tem( ra=y ramp or timbers free grade to slob to prevent damage to concrste edge from equipment. trar"Ic. £.) Instou CEPS r. d flange braces onto co1urrinn and rafters before these mel=ibes are in thee. air. Clip and r`lang brace roca:lonn are shown on erection drawings. GENERAL ERECTION NOTES 1.) All clips, flange braces, baits, bracing systems. ETC, must be installed as shown on erection drawings. 2.) It is extremely it portant, especially during construction, that panels at the eaves, rakes and ridges be kept secure. 3.) Column bases Use, must not be lag screwed or "RED HEADED" to concrete unless specified on erection. drawing,, for the building. 4.) Tighten column wind brace rods/cables (exterior and interior) before tightening roof rods/ccbles. Roof rods/cables are tightened from save to peak. 5.) High strength bolts (A325) must be used where specified. TEMPORAF<Y CONSTRUCTION BRACING 1.) It is the responsibility of the erector to maintain stability of the structure during all stages of erection, parilauloriy when left overnight. 2.) Temporary s�.epport's, such cis temporary guys, braces or other elements shall be the total and complete responsibi!ty of the erector. TI1e temporary supports required shall be determined and furnished by {Ute erector. .) Temporary constructon supports shall be provided wherever necessary to accommodate a!! construction loads to which the structure may be subjected, left in place as long as may be required for safety. PANEL CAUTIONS AND NOTES To minimize poterliial of ccd'rosive action at the bottom edge of wall panels, the contractor must assure that tnc i 4 w,r•g procedures are folluled: 1.) The concrete f undatihn should be cured for a minimum of seven (7) days before wall panels are installed. (uncured concrete is highly ol.`y-c!ine and metal panels can undergo varying degrees of corrosive attack when re direct contact with the concrete.) After the first week of the curing eyt;lc, the reaction betses(l metallic coatings on steel and the concrete is essentially halted. CLEAN DIRT FROMj/-WALL PANEL .AROUND PP.NEL BASE \ PANEL NOTCH (FROWN) OR._.,WNDATON BASE TR!L' n a SOPE FINISH GRADE AWAY c N. x FROM BUILDING �`-✓ 2.) Top of finish grade at building to be a minimum of four (4) inches below bottom of panel. 3.) Finish grade is to slope away from bai'.ding to ensure proper drainage. 4.) Upon completion of finish grading, all dirt is to be cleaned from around base of wail panel where it may have collected in panel notch or on base trim. FAS"! ENTER INSTALLATION Correct fastener nstallotion is one of the most critical steps when installing roof/wall panels. Drive the fastener in until it is tight and the washer is firmly seated. Do not overdrive fasteners. A slight extrusion of rk;n+xene around the wisher is a good visual tightness check Always use the proper tool to install fasteners. A, fastener driver (screw gun) with a RPM of 1700-2000 should be used for self -drilling screws. A 500-000 RRMI fastener driver should be used for self -tapping screws. Discard worn srckets, these can cause the fastener to wobble during installation. .TIS ' �5112/J-1L1 CORRECT DEGREE Or TOC TI ii SEALANT SQUEEZED TOO LOOSE SEALANT IS TIGHTNESS NOTE SUCH' TOO THN EXTRUDES FAR BEYOND NOT COMPRESSED To CIRCLE OF S.A!A+T FASTENER HEAD FORM SEAL NOTE: Always rcmove meto! filings from scrface of panels at the end of each work period Fa +Ing f1iings can destroy the paint finish and void arty warranty. 3A STIC SEALANT Proper mastic application is critical to the weather tightness of a building. Mastic should not be stretched when installed. Apply only to dean, dry surfaces. Keep only enough mastic on the roof thot can be installed in a day. During warm weather, store mastic In a cool dry place. During cold weather (below BO°) mastic must be kept warm (80°-90°), until application. After mastic has been applied, keep protective paper in place until panel is ready tc be installed. IMIPORTANT NOTE: All details, recommencirtians and suggestions contained in the ERECTION GUIDE portion of this drawings set are for general guidelines only, and not meant to be all-inclusive. Industry accepted installation pica I S with regard to all areas not specifically discussed In this section shoed be followed. Only experienced, knowledgeable installers familiar with accepted practices should be used to assure a quality project. It is emphasized that the Manufacturer is only a manufacturer of metal building components and is not engaged in tie installation of its products. Opinions expressed by the Manufacturer abc,0 installation practices noted in the ERECTION GUIDE are intended to represent only c guide as to the sequencing and holy the components could be a sen trod to crea._ a buildina. Both the quality and safety of installation and the ultimate customer satisfaction with the completed building are determined by the experience erpeitisr and Wile of the.installation crews, as well as the equipment avolaale for handling 4he materlols. Actual installation operations, techniques and site conditions ore beyond i"e Manufacturers control. STEP 1: ERECT FIRST BAY WALL FRAMING NOTE the It is the responsibility of rovide tem or RIMARY FRAME erector to P temporary erection bracing 9 unfit the structure is completed. STRUT END FRAME �\ RAFTER / END POST J CORNER COLUMN 1A: Determine from erection drawings furnished with the building the location of the first braced bay. Framing for this bay will be erected first. 16: Stand adjacent primary frame column and corner column over the anchor rods. Shim or chip out under the base plate if required to ensure that the base is level, at the correct elevation, and is in full contact with the foundation. Plumb and align the columns and install washers and nuts onto the Anchor Rods. NOTE: The end frame may be a bearing frame with the rafter supported by end posts, or a rigid frame with the rafter self-supporting, and clot attached to the end posts. The procedure shown is for a bearing frame. If the building has a rigid end frame, it is erected the some as interior frames as described in steps 1 and 2. 1C: Attach wall girts to the primary frame column and corner column. Bolt girts to the corner column with two bolts. Bolt in to primary frame column 9 9 P Y with one bolt through the column flange and secure bolt with sub -nut (see detail on erection drawings). 1D: Install the eave strut by bolting to the top of the columns. Refer to the erection drawings and attach column flange brace where shown. Flange braces may be required on one or both sides of the columns. If a flange brace connects to a girt in the adjacent bay, that brace will be bolted to the girt after the adjacent bay girts are installed. NOTE: As wall girts are installed around the building, framing for factory located framed openings and accessory framing to which the girts attach should be installed. Field located accessory framing may be installed at the some time as girts or at a later time. 1E: Install wall bracing systems (rods, cables, knee bracing, portal bracing) at this time but do not tighten completely until the bay is plumbed. 1F: Repeat steps 1B thru 1E for wall framing on the opposite side of the building. 1G: Attach clips to the end posts and stand these posts over the Anchor Rods. Follow therocedure as described for corner columns in step 18. P P IH: Bolt required clips and flange braces to the end frame rafter sections and lift into place atop the end posts. Bolt rafter sections to corner column and end post cap plates. Bolt rafter sections together at peak. STEP 2: ERECT FIRST BAY ROOF FRAMING PURLINS NOTE It is the responsibility of the erector to provide temporary erection bracing until the _�. r-`RIMARY FRAME structure Is completed. END J FRAME END POST ERECTION BRACING CAUTION Until rafters are bolted in place with l:purhns and flange braces installed, they are easily damaged by incorrect or careless hanadling procedures. Use extreme caution when lifting rafters. Two booms should be used to) lift any pinched rafter section 80 feet or more in length. 2A: Bolt primary frame rafter togetheer at peak connection (unless rafter length requires lifting in sections). Attach the requireed clips and flange bracesto the rafter before lifting since these items are more easily insttalled on the ground. Lift rafter into place between sidewall columns and install bolts in rafter to column knee connections. 2B: Install end bay purlins from end ffrome rafter to the first interior frame rafter. The end bay purlins will overlap the intariopr bay purlins at the frame as described in step 1C. Complete flange brace connection to (purlins. 2C: Install roof bracing systems but ddo not tighten completely until the bay is plumbed. 2D: Plumb and square the first bay. ;.After alignment, tighten wall bracing first and the roof bracing working from eave to peak. Tighten any remaining bolts. Plumbing and aligning a total structurral system begins with the first braced bay and continues through completion. Accurgtte alignment of the first bay is essential for correct alignment of succeeding bays. The insitaller is responsible for choosing the best method suited for plumbing and aligning the sstructural system. STEP 3: ERECT ENDWALLL GeRTS AND FIRST INTERIOR BAY NOTE �,,� It is the respensibillty of the END BAY of erector to provide temporary PURLIN erection bracing until the structure is completed. TEMPORARY ERECTION BRACING END FRAM's RAFTER '-END BAY GIRT END POST / ENDWAL I ORNER GIRT COLUMN 3A: After end frame is plumb and saquare, install endwall girts and flange braces for end post if required. 313: Attach wall girts to the primary frame columns (see step 1C). 3C: Install Dave struts (see step 1D)J. 3D: Attach roof purlins for this bay to the two rafters. Purlins will bolt to the rafter flange in the same manner as girts Ito column Ranges (see step 1C). Connect flange braces to purlins. 3E: Check alignment, plumb and squaare the two boys just erected. Tighten all bolts and bracing. EAVE STRUT FRAME END POST STEP 4: ERECT REVALNNING STRUCTURAL FRAMING NOTE It is the responsibility of the erector to rovide tem orar F I- P P Y PURLINS -t..r erection bracing until the .� structure Is completed. 4)RBAARY FRAME ERECTION BRACING Starting at the opposite end of the first bay erected, install the remaining interior frames, girts, purliiins, eave struts, bracing, end frames and end posts using the proocedures describes in the BUTTE COUNit� preceding steps. Be sure all wall girtts, roof purlins and flange i IJ C braces as shown on the erection drlowings are installed. tk ,.>IIL6 � V�,L- 0o1�,� Constant checks should be made to ensure the building is �p� square, plumb and aligned. i'YWr�,�k( All X -Bracing should be checked thmt H is installed to a taut �{ condition with all slack removed. Do not tighten beyond this state. REVIEWED LU . FOR CODE COMPLIANC NOV 10 2016 WNVSIJL.I (N(3 G1 UILItJ 'I'f 1 11i iI' j I' STEP 5: INSTALL SIDEWALL PAkkiELS PANES NOTE It is the re.^,.ponslbility of the erector to provide temporary em ctlon bracing until t!;e structure is completed. This bracing is to remclri in place until ell roof and wall panels are installed. LOCKING FOR GIRT ALIGNMEN 5A: Beforenstalling wall panels, the g!rts must be aligned to a level position ;,o that there !s no visible sag. This should be done directly ahead of panel insto lotion. Girt leveling may be accomplished by standing a section of gable angle , .,,rIIk;c0y agalnst the out.vidv gI4 flanges at approximate mid -b, -,y location. Tanen cirts are level, attach the q!rt flanges to the angle with vise grip pliem or tetr+porary screws. Wood t,;aciclog cut to fit the spaces may also be used far a!gnrnerit. NOTE: Temavrary air` biockir; !s Prot recom€nodded on concealed fastener panels. Tire removal of the hocks after panel Instaflotori can cause oil a r 5 _OCKiNB We'! panel. 'Iype and lrct on dett,iis will vary. Refer to the eracton 9 ca _';es cn ; e -tails for th pecific panel used for your b� Idinq. .s .., s r``-CONl"ACT TAPE MUST nh T"LID✓All- a✓tiy -GA E ANCLE/1PNI IN U!P ION T0 SEAL T'r!E CORNER CONTACT TAPE 58: If wails are to be insulated, place a continuous run of contact tape Gong the eave ,nrut and base r^ernber, ha�G At the base, cut aff the ins-u1a`;^n a minimum of 1/2" above the bottom of the wall panel. It mea prey-nt the irriulation from, hcngir..g below the tsall panel and wicking m, iSWr€. Roof Panel Double Faced Tape � " ' � (Nut by manufocturer) (Not by monufat+u er) n to be used to secure `' Time` insu!aticn. ;?�� 'lYim insu�atlon ar:d turn vinyl DOCK insulation must not be exposed to !I s3 Iweather. 1:'lh II "� (Feat by manufacturer) Fiberr'rs., lraul rn � �'f � t`anar Perrier to to OUTSIDE o` Ru:ldirc I II 1 Iv 1DE of nnMng sN Fn ✓el alai (See Era. kion Drowings) Not v- .� ! t tsc„e Trim insulation ar.d VVCII Pon 1--\ I� I j �r) turn h ny. bac'; Insulation trust not he exposed to li k"� tn,cfio I weather. tE � �/�� NesrTVpetail f _ (Ss -e Election Drawings) Sior'lrg s i c b ' ng carrier, 'k rh the first piece of blanket i ulation. tc the Contest tePc on the cave I P'. ­,fl VO4, and adhere to ta- e at the base. it is rece.ma.hded that nvilcllor. riot be ins.alied more than 6 feet ahead of I)Cne e. I R4 Ernlion Guide I_=. 5C: Sidewail panels s.hou!d be !nstal!ed so that the panel sidelap is in a direction away from the prevailing viir:d. (refer to appropriate lap detail included with erection di awings.) 5D: Install remaining sidewefi insulation and panels, being careful to maintain correct panel coverage. If is suggested thatthe foundation be marked in increments of panel width to alio-.v visual: checking of panel coverage as installation progresses. NO -EE: Check pariodically to ensure that all panels are aligned and plumb. 5E: At the finishing comer of a sidewoll, the last panel may required additional lap or trimming for insto!latien of corner trim refer to the details in the erection drawings. TEMPLATE S4EET STACKED SHEE TO BE DRILLED Screw Alianmerit Panel (Through Fastened Panel Only) NOTC_ ALIGNED After drilling pane's, it is important to clean metal filings off all panel surfaces, including between panels that are not installed that day, to avoid rust stains. STEP 6 INSTAL__ENDWALL PANELS MEW 6A: Install gable angles/supports onto the ends of purlins and eave struts. This angle is to butt -up to each other or is spliced as required except at expansion joints where a one inch gap is maintained between ends of adjacent sections to allow for expansion. :Cable angle splices may occur on or between purlins and the angle must be attached to each purlin and the, eave strut. NOTE:._ Wall panel type and installation details will vary. Refer to the erection drawings and details for the specific panel used for your building. NOTE END FRA' j UPIIV Detail shown for ribbed roof RAFTER a w f GABLE panel only. For standing seam `, vGLE AT rake and gable angle installation, /,' see erection details. e . •"y e` EXPANSION �1 JOINT T !CA iii {AVE STRUT BUTT LAP COAIDITION 63: See erection d,arfn,g net.ing layouts for panel starting dimensions, panel trim loeciicns, and lop locatiors. TR!M DIMENSION IS ` MEASURED FROM TRIM-- 1 CENTER OF FIRST MAJOR RIB. GABLE ANGLE /� PURI -IN CONTACT TAPE —�� EAVE STRUT ENDWALL GIRT WOOD BLOCKING ---- BASE ANGLE/TRIM —\ CONTACT INSULATION 6C: Align and level girts on endwall 60: If the walls are to be insulated, place a continuous run of contact tape along the gable angle and base member. Starting at the corner of the endwall, attach the first piece of insulation to the contact tape on the gable angle, pull tight and adhere to tape at the base. Cut off excess insulation. It is recommended that insulation not be installed more than 6 feet ahead of panels. NOTE: At the base cut off the insulation a minimum of 1/2 inch above the bottom of the wall panel. This will prevent the insulation from hanging below the wall panel and wicking moisture. 6E: Start at the corner, trim panel (if required) and set in place. Refer to corner details in the erection drawings for the panel starting distance from the corner, When the panel is located and plumb, install fasteners. 6F: Install remaining endwall insulation and panels, being careful to maintain the correct panel coverage as suggested in step 5D. 6G: Install corner trim, STEP 7: INSTALL ROOF PANELSNOTE It ' th bill} f Is e responsy o the erector to provide temporary erection bracing until the tructure is completed. is bracing is to remain in place until all roof and wall panels are installed. PANELS HANLLS LOCKING FOR ICNMENT 7A: Install eave trim over top of sidewall panels and eave struts with fasteners per erection drawings eave detail. 7B: If the roof is insulated, place a continuous run of contact tape along top of eave struts at both sidewalls. Lay a starter roll of blanket insulation from eave to eave across roof and secure to contact tape. (refer to packing list for width of insulation starter roll). It is recommended that insulation be installed no more than 6 feet ahead of panels. STEP 7: INSTALL ROOF PANELS (Can't) 7C: Install the first run of roof paneels across the building from eave to eave, or eave to ridge. To allow proper insstailation of rake trim, the starting location for the first panel must be as shown in rake details included with the erection drawings. When the firstt run is properly located and aligned with the correct endlaps and eave overhanng, fasten to purlins. Roof panels should be installed so that the sidelap !ss in a direction away from the prevailing wind. Refer to appropriate lap detail.. 7D: Install remaining roof insulation (and panels. To avoid accumulative error due to panel coverage gain or loss, Ipropedy align each panel before it is fastened. Occasional checks should bee made to ensure that correct panel coverage is maintained. Special attention should be given to fastener, mastic and closure requirements. Refer to ddetails with erection drawings. 7E: At finishing end of roof, the lostt panels may require field modification for installation of rake trim. Refer to rokke details. DO NOT BACK LAP THROUGH FASTENED ROOF SHEETS. NOTE: Roof panel types and insto9oltion requirements will vary. Refer to the appropriate details for the specific poanei used. IMPORTANT: Loose fasteners, blind rhvets, drill shaving, ETC. must be removed from roof to guard against corrosions. _NEVER STEP ON LIGHTr TRANStAITTING PANELS, TRANSLUCENT PANELS OR UNATTENDED ROOF PANELS. Panels May Collapse If Not Properly Secured! Roof panels must be completely attochaed to the purlins and to panels on either side before they can be o safe walking surfeoce. Light transmitting panels or translucent panels can never be considered as a wracking surface. Partially attached or unattached (panels should never be walked on! Do Not: 1. Step on rib at edge of panel. 2. Step near crease in rib at edgge of panel 3. Step within 5 feet of edge on unsecured panel. A single roof panel must never be usecd as a work platform. An OSHA approved runway should be used for work platforms! (Coonsuit OSHA Safety and Health Regulations for the Construction Industry). Safety First! NOTE: For PSR roofs with a ridge panel, it is recommended that both sides of the ridge of a building be sheeted simultaneously. This will keep the insulation RAKE covered for the maximum amount of time and the panel ribs can be kept in TRIM proper alignment for the ridge panel. This is critical on the "PBR" panels so that the ridge caps con be properly installed. Check for proper coverage as the sheeting progresses. Note panel -sheeting sequence below! STEP R: INSTALL TRIIIb1 AND ACCESSORIES "„� GUTTER SA: Install rake trim and gable closure. 8B: If included with the building, install the eave gutter, corner closures and downspouts NOTE_ Remove all loose fcsteners, blind rivets, drill shavings, etc... from gutter to guard against corrosion. N Li u man m zamZ d �00U0 o a N r`-- �0"Um O Saole� NCT7C SCALE firown by JOE 7/15/16 Checked by: JAM 7/15/16 Job Number. 15–B-39475-1 Sheet Number: R4 of 21 The engineer whose seal appears hereon Is an employee for the manufacturer for the materials described herein. Sold seal or certification is limited to the products designed and manufactured by manufacturer oney.The undersigned engineer Is not the overall engineer of record for this project. Ronald W. Bennett. P.E BC: Install accessories (doors, windows, louvers, etc...) not previously installed. Refer to TION the appropriate details for installation instructions. IMPORTANT: Remove debris from roof mind wall surfaces during installation and after. , Clean surface of sheeting as required too remove smudges and touch-up any minor/mild I scratches with color match touch-up paint. REVIEWED PJUT1 * ClDuro +` FOR CODE COMPLIANCE INTERWEST CONSULTING GROUP t T 1 EXTENCIECC('J1'IECT,ON F'LAiE f ' AN• r`ur r AND BR,ACKE7 TO FLANGE Tr s� _ L!MiT S� —DETAIL I--' O" 70 1/16" 4 F'LLEi:S NOT ALLOW D c, ON CRANE BRAC: iS i, I EXCEPT AS NOTED ON — ' Ys5'6. USE OE,AILS 82 AND B, i ON CRAIVE" BRACKETS IfIERE FILLET I-,Lt_DS ARE NOT .'Lt_OMM S Ir T= 3 J5" OR LESS FLUSH OR P,ECESSL7 CONNECTION PLA. TE AND 3RAC'KIT TO FLANGE C-11) . 1) IJ L/ To 7/16' --T1 \BACK GOUGE i( X/1," GENERAL NOTES AND DETAILS WS -1A Date Issued: October 30, 2015 EXTENDED, FLUSH OR RECESSED CONNECTION PLATE AND -BRACKET / TO FLANGE l BACK GOUGE 45'— T = 3/8" OR LESS ROOT FACE PER KP5 1112" TO 2" ------ - DETAIL 3 GENERAL ,(. i= GUIDELINES_ C,6F5 T,O-a� ---- j— - _ L!MiT S� —DETAIL TO USE PIA 7F V sli.NGE THICKNESS LLS, THAN Ok EQUAL TO 3,/13„ Bl ' 114' 1 r4 J;r 11/2"1 CONNECTION PLATE IS EXTENDED EAST FLANGE ENOUGHTO ALLOW REOFILLET LET SIZE PLA 7E I! I TO CO''-0NECTION PLATE --'-- _ "— FLANGE THICKNESS LESS THAN 0 EQUAL TO 3/8" B2 ! VIC C 'NECTON PLATE IS FLUSH TO ZECESSED TO FLANGE SIUPFACEFi LFLANGF ,NGE Hi. KNESS Gr CATER /NAI 3/8" B3 2 ACKEI FLANGE THICKNESS LES`. THAN OR EQUAL TO 31'3_.x_----- 32 CRA—NI-E--BRACKET TO FLANGE BRACKET FLANGE. Tirlik,XNESS GREJER T IAN 3/8i" 33 NON—CRANE, 8''ACKET TO ELAINGE '- NON—CRANE BRACKET FLANGE THCKNESS i_ESS THAN OR Bl 114-1 r147i.- _. NON—CRANE BRACKET FLANGE THICKNESS CREAT R THAN 3/8" �— B3 I/4" W �I E PLATE THICKNESS LESS �'-AN OR EQUAL TO "/8"-- ' 31 I1'U!I;'1'` R. -ANG, T� !r9neryc;�i* .�F.�;-_ HL^TF 1 rRf[RIDEU PAST WELDED PLATE ENOUGH TO ALL.041? REQUIRED FILLET SIZE PLATE, STiFFENER I- CONVECT, LLg 4 �nt1 PLATE OR ANY CONDITION Ca' I. ;> WELDED PLATE THICKNESS LESS -IAN OR EQUAL To 3/8" 32 FOR DRIAIL B PUT NOT MIENTIGINFO PL DO7 , NOT EXTEND PAST WELDED PLATE ENOUGH TO ALLOW REQUIRED FILLET SIZE E -ATE WELDED PLATE THICKNESS CREAITR THAN 3/8" 33 Y I RI's SDE 0 PLA Ile I D\ 'ti: 'J DETAIL P— 1 A SEE NOTE C2 kV DETAIL C—TA 1 L, I"'? T D ��DI"!.i a'EG T_lON �Lfi T AND ET�ACKF—i TD FLANGE HECK COUGE IFLAT OR HORIZ. 3A.CK G::^UGC' GMAY, O, '� BACK GOUGE SAS' 1 u l i6' I "��""'Yi' � � � �' 0 - 1/16°° 4 O WF3 Cha 41'r t 0.'' PLATE / I I`- i I Foe rAn;E SPLICE I ' u> \ IN IWe WIGS SIDE GF PLACE in Me i I OF OF PLAIT Rol? FLANGE S�UGE Far FLA 1g SPLI^E GOUGE C4 —(BACK GOUGE +12 St\BACK GOUGE GMAW45 \ — i �.,9A& , 'CK 60 SAW 45 `L I O" — 7/8 VfiFi rrf5 �D. t%F PLA`,E 1x OF& PI.- &a a"' PLATE Fa'. F Ah'GE SP1It- C WW .A'„L' 91I)cr O tI NFE 115 SIDE OF PLATE i x -CSR FANCE SPUCs O ! 2 W3 Trr SIDE OP, MATE F- "a4 rVI? FLVG2 SPLICE 4DETAIL C— 1A NOTES SPLICE KIELDS C2 ANY PREOUAUFIED OR 'PROCEDURC OIIAN-rED' CJP WELD MAY ALSO BE USED FOR D -TAILS B AND C, WTH A WRITTEN NCI APPROVED WSoDS p:` 112 PICK+DESS 7RANSI770,11 PEOWR03 FOR CANADA PROJECTS TABLE 2 II GENERAL r1LLET KELDS I of )%1 �Dt � c,e SI, N( .WINNER FLA7E FLLtT FILLET 7HICKNE S SIZE SIZE UNOER 714 3116" 7 o" I _ '14 114" �Vlti .l I Ob�R 511E 5111" 5/1F" TABLE S;NGLE PLATE WELDS i MLN. FILL E r WEri SILL S s;^Es PIA 7F T' ---ET 7;'il ' P(Lai ' 114' 1 r4 J;r 11/2"1 S1T_E PLA 7E 4/18, r ..314" UNm? 1/4 ! VIC 114 � o a b h= P 4t 7/. j /sc a Iq� 31 � 31 I <rt6 �3Ato- 114-1 r147i.- 114"! 114 I/4" rVErr 314 ,1115 7r`•4 h I "i 4; a r:.5116?. LLg 4 �nt1 TABLE 2 II GENERAL r1LLET KELDS I of )%1 �Dt � c,e SI, N( .WINNER FLA7E FLLtT FILLET 7HICKNE S SIZE SIZE UNOER 714 3116" 7 o" I _ '14 114" �Vlti .l I Ob�R 511E 5111" 5/1F" TABLE S;NGLE PLATE WELDS BOTH .S7i �I s;^Es PIA 7F T' ---ET 7;'il ' P(Lai S1T_E — {/4 ..3/16 _._ .. /6 7/4 3,.B 114 BACK GOUGE 20 R=1/4" C5 GENERAL NOTES 1. ALL SAW WEB TO FLANGE WELDS TO BE CONTINUOUS ONE SIDE (ONLY UNLESS NOTED ON FABRICATION DOCUMENTS. 2. INCREASE FILLET SIZE BY 1/16 FOR EACH 1/16 OF GAP IF GAP AT ROOT 1S GREATER THAN 1/16. MAXIMUM FILLET ROOT PERMITTED IS 3/76. SEE DETA;L O -7A ON THIS SHEET. J. FILLET VELD SIZE IS NO GREATER THAN THE SHORTEST LEG SIZE-. 4. FOLLOW APPROPRIATE WELDING PROCEDURE SPECIFICARONS FOR' ALL WELDS, 5. ALL CLIPS SHOULD BE YIELDED AT 90 -DEG TO 771EiR SUPPORPNG; SURFACE UNLESS OTHERWISE N07ED IN 774ESE DRAWINGS OR THE PROJECT SHOP D,PRAYfINGS. 6. SC2 AND SC280 FLANGE BRACE CLIPS SHOULD BE ALIGNED W+TH THE PURLIN/GIRT CLIP ABOVE. REFER TO DETAIL ON SHEET W5-5. FILLET INCREASE AT SKEW INSURE THAT FILLET LEG SIZES ARE ACHIEVED GAP DUE TO SLOPE BEVEL OR SLOPE 2:12 = 9 DEGREES 4:12 = 18 DEGREES FOR SLOPE BETWEEN 2.-12 AND 4:12 INCREASE FILLET 1/16". FOR 4:12 SLOPE AND GREATER USE CJP. GENERAL NOTE NO 2 IS IN ADDIRON TO SKEW 19NCREASE MAX. OPENING ALLOW 0 IS 3/16. THEN USE CJFP. IF REOUIRED FILLET EXCEEDS 5/16 THEN USE CJJP. DETAIL A— 9A a U m� v G INCP.EASE FILLET IDEAL FIT—UP FIT—UP CAP BYY AMOUNT OF GAP z a Oa4 Z � 4 E c FILET rRE N « 00(>z srzE DESIGN FILLET SIZE J T cnpa 3 �" 3116" 1 1/4" 5/16'" i ci c� N U m C FScale: NOT TO SCALE g -i —_ USE CJP SEE NOTE 2 DETAIL D -1A FILLET /INCREASE BUTTE G07if, ,y CIVISION REVIEWED FOR CODE COMPLIANC NOV 10 2016 INTERWEST CONSULTING GROUP Checked by JAM 7/15/16 Project Engineer. SG Job Number: 15—B-39475-1 Sheet Number R5 of 21 appears hereon is an employee for the manufacturer for the materials described herein. Said seal or certification is limited to the products designed and manufactured by manufacturer only.The undersigned engineer Is not the overall engineer of record for this project. Ronald W. Bennett. P.E. Q mp!i � o a C f� bZ<� f~'. z LLg 4 �nt1 E INCP.EASE FILLET IDEAL FIT—UP FIT—UP CAP BYY AMOUNT OF GAP z a Oa4 Z � 4 E c FILET rRE N « 00(>z srzE DESIGN FILLET SIZE J T cnpa 3 �" 3116" 1 1/4" 5/16'" i ci c� N U m C FScale: NOT TO SCALE g -i —_ USE CJP SEE NOTE 2 DETAIL D -1A FILLET /INCREASE BUTTE G07if, ,y CIVISION REVIEWED FOR CODE COMPLIANC NOV 10 2016 INTERWEST CONSULTING GROUP Checked by JAM 7/15/16 Project Engineer. SG Job Number: 15—B-39475-1 Sheet Number R5 of 21 appears hereon is an employee for the manufacturer for the materials described herein. Said seal or certification is limited to the products designed and manufactured by manufacturer only.The undersigned engineer Is not the overall engineer of record for this project. Ronald W. Bennett. P.E. 1 A`EAR Sk: F"Af 3, lD BYPASS L -!R-, Q9 AL-,ERIJATE_EAVE- 5TPN (1, -_SUPPORT ANC:; E. I c7AtL B— rRlA.LI F"L TAfa] E 2 DETAIL B -- FCETAIL E --IA �l iI I (4 -. CA,N'OP}' AT FLUSH CCr UA, R 5017 AND S/Dw LA ;J EAW CAAICPY OR FACAIE BRACKET NEAR SIDc AND \}--- FAR SIDE 3f16 NEAR SOF AN:`<\,.._.,.—._.—� NEAR SIDE !ND. \ @1 LCAN TO BRACKET L -- /H%L_ COLUMit't EA: VE. TABLE 2 FULL LENGT ; IF D = 10' OR LE:S DETAIL F-2 VARIES TABLE 1 FN'O,V. CAP PLA TO STIFFENER TABLE 1 SA. W. F RL ' F_NG7H OF FL..ANGES PAY INCLUDE CON.NEC7TON PLPL. VFTAX C -1A. .T -H" V TABLE 2 2 DETAIL C—"A T`PICAL B'ACE. REINFORCLk1ENT 3/1Fi X TYPIsAL COLUMN WELDS DETAIL B -1f TYP. STRAIG1dT OR TAPF_RLD r DETAIL B -1A O O O O MAY BE SAW AND LARGER IN THE FLANGE WELD PER OR WHEN HOLES ARE 13/16" TABLE 2 TABLE 1 AND LARGER IN THE WEB 7YP. -f- ATABLE z AND WITHIN 12" OF .A FLANGE 11 I DETAIL B -1A O O COLUMN AT MEZZANINE BEAM _ OR ATTACHED TO WEB VJTHIN 12' - DETAIL E-2 SECTION H VIEW 3" --t TABLE 2 Lu U RIGID FRAME COLUMNS WS -2 Date Issued: October 30, 2015 w / k '42 -{ DETAIL B -IA r DETAIL C -1A 3/8" OR LESS rz `r I WELD TRANSITION FOR CANADA SEE W5-16 DETAIL C—IA 0 45• WELD 7RANS177ON FOR CANADA SEE WS -1B i"moi y L WELD TRANSITION FOR CANADA SEE W5-123 / DETAIL E-2 ABLE 2 NOTICE — WHEN FLANGE IS SLOPED LOCATE .�.�A,ABLr 2 _ FILLET KEL'D ON OUTER SIDE OF FLANGE I/' \ IF' EASE PLATE 1S EXTENDED ENOUGH TO ALLOW. REFER TO DETAIL D -1A FOR f,ELD GUIDANCE D.'TAIL. C-2 BASE PLATE ON FILLETS AT SKEWED JOINTS. -P0X,'L. L? -1A 110MENT BASE PLATES E2 B --1A WELD COPED GUSSET P£R� TABLE 2 WHEN PRESENT , TABLE 2 FULL LENGTH IF D = 70" OR LESS 3" DETAIL F-2 VARIES TABLE 7 FROM CAP PLA7E DETAIL TO S77FFENER TABLE 2 —re—q�\—(TABLE 2 `DETAIL C— STRAIGHT OR TAPERED EA VE STRUT BRACKET TO BE NWELDED IN PLACE AFTER THECOMPLETION OF THE HAUNCH LD TABLE: 2 I_ TABLE 2 DETA. V NCI KNEE CONNECTIONS MAY VARY AIS SHOWN SINGLE—PLATE (if present) TABLE 2 WELD CONTINUOUS 1 1/2" BEYOND BOLT GROUP or SINGLE PLATE, ON SIDE OPPOSITE FROM SAW WELD. DETAIL E TOP AND B0 DOTH SIDE! COLUMN FU TABLE 2 TO [BEL 0 W EA VE BRA CKET BUTTE COUNTY BUILDING D'MMN PR0 F 2 AND TOM TENER REVIEWED FOR CODE COMPLIANCE NOV 10 2016 INTERWEST CONSULTING r;Rni m D 0 9% o v, 67 a `o w= Z El al vws 30 6 UN F Z 4 4 00 ❑ ❑ 0¢n jm z<�z CO>az rn E OOOO o, .a, OU OZ .0 Z U4 3 .l. Aria: O U U'NUm O Sco/e: NOT TO SCALE Drawn by JOE 7/15/16 Checked by. JAM 7/15/16 Project Engineer. SG Job Number. 15-B-39475-1 Sheet Plumber. R7 of 21 The engineer whose seal appears hereon is an employee for the manufacturer for the materials described herein. Said seal or certification is limited to the products designed and manufactured by manufacturer only.Theundersigned engineer Is not 'he overall engineer of record for this project. Ronald W. Bennett. RE HOLES ARE 13/16" L� AND LARGER IN THE FLANGE rWHEN OR WHEN HOLES ARE 13/16" TABLE 2 AND LARGER IN THE WEB 7YP. AND WITHIN 12" OF .A FLANGE OR SINGLE PLATE WITH 13/16" AND LARGER IS ATTACHED TO FLANGE COLUMN AT MEZZANINE BEAM _ OR ATTACHED TO WEB VJTHIN 12' _ (WHEN REQUIRED) OF FLANGE ,'AL?LE 2 n;IR. TABLE 2 TO [BEL 0 W EA VE BRA CKET BUTTE COUNTY BUILDING D'MMN PR0 F 2 AND TOM TENER REVIEWED FOR CODE COMPLIANCE NOV 10 2016 INTERWEST CONSULTING r;Rni m D 0 9% o v, 67 a `o w= Z El al vws 30 6 UN F Z 4 4 00 ❑ ❑ 0¢n jm z<�z CO>az rn E OOOO o, .a, OU OZ .0 Z U4 3 .l. Aria: O U U'NUm O Sco/e: NOT TO SCALE Drawn by JOE 7/15/16 Checked by. JAM 7/15/16 Project Engineer. SG Job Number. 15-B-39475-1 Sheet Plumber. R7 of 21 The engineer whose seal appears hereon is an employee for the manufacturer for the materials described herein. Said seal or certification is limited to the products designed and manufactured by manufacturer only.Theundersigned engineer Is not 'he overall engineer of record for this project. Ronald W. Bennett. RE ftl-'L OR PARTIAL DEPTH STiFR-&,ERf AS bET4111-D TA8:1.E 2 /'-- T:ABLF 1 COJT 1 1/2- pi%YOND CONN. MOLLS DETAIL C --IA AT FLANGE TABLE 7 FOR FULL DEP7:N STIFFENERS TABLE 2 RIGID FRAME RAFTERS WS -3 Date Issued: October 30, 2015 �f V TABLE 2 — GM AW WELD 1 1/2" PAST BOLT J DETAIL B -7A PATTERN FOR 13/16" HOLES AND CETFlK C -IA r _ _ LARGER IF BOLT PATTERN IN WEB THICKNESS TRANSITION FOR CANADA SEE K5 -1B IS WITHIN 12" OF FLANGE. 3/76 DETAIL B -1A � ..--- AVE G? TUSE COLUh4iJ DETAIL. C -IA "K " FULL ORPAR77AL DEPTHo O LESS /I S77FFE)N&S AS DEMILE.D _ J,� 0 o 12� OR TABLE 1 J. 1------ _-.----��� ✓-''�� �jV TABLE 7 I 11� TABLE 2 3" \ TABLE 2 TABLE 2Y� >T, IL C- IA �A THICKNESS 7RANS177ON FOR CANADA SEE WS -IB , / TABLE 1, S.A.W. i i ✓')FTAB-IA FULL LEND -H DEALL C -1A I "K"a ..II WELDER ID STAMPS - ON FAR SIDE DETAILB-tA SECTION K VIEW (NEAR INNER FLANGE WITHIN 6" OF END) FL`LL OR PARP,AL DEPTH STIFFENERS AS DETAILED ---- DETAIL C -IA PIPE OF TUBE COLUMN DETAIL. ?-TA �i TABLE 2 / TABLE 7 CONT. 1 i/2" B=YCND COMM. HOL ES .,� �-- DF, TAILB-A, FLUSH C'OA95i TICPi GRINO W1 DS FLUSH 1,9HEN FL,NGE HAS HOLES 17AFTER, INTERIOR SUPP(RTS TABLE 2 TABLE 2 TABLE 1 FORFULL -- DEPTH STIFFNERS SAW / 7:ASLE i C9T, BE'WEEAI STIFFENER: 74;+LF 7 \_ - I .. �' �- DETAIL E-2 / I i.I -- TABLE 2--��.-1 '`�/.�' `�`� VIF OR BU?LT-UP ` COLUMN COLUMA' AVN LL) COt:WECTION %ALL HOLES ll-tr`DE Cir" RANCES OR 4T(f`'"E-AIERS) TABLE 2 DETALL B-lA - SAW PULL-THRU WELDER OPERATOR - HAND FITTER RAFTER TAPER MAY VARY AS SHOWN - HAND WELDERS (CENTER ON FLANGE) TYPICAL RAFTER WIELDS DETAIL B -IA DETAIL TABLE 1 FOR FULL DEPTH S77FFENERS ^_ 3AWjABLE 1 CON7 -(BET4IEEN STIFFENERFFENER S \ AND 1-1/2" BEYOND OUTER CONNEC77ON HOLES A4 'L DETAIL E-2 DFTAII_ B--tA TABLE 1 3" FOR BUP TABLE 2 WF OR BUILT-UP COLUMN COLUMN MOMENT CONNECTION (HAS BOLTS OUTSIDE OF FLANGES OR STIFFENER) WELD COPED GUSSET PER TABLE 2 WHEN PRESENT TABLE 1 8"am e�-- /--� TAIL B -1A( TABLE 2 u 3/16 TABLE 2 F /TABLE 2 ' jjJ TABLE I TABLE 2 COPED GUSSET PER DETAIL B -1A 2 WHEN PRESENT (TM) RAFTER MAY VARY AS SHOWN THIS 57TFFENEH WILL HAVE HOLES AAND MAY OCCUR ON ONLY ONE SIDE OF WEB HIP RAFTER STIFFENER FOR SKEWED RAFTER SUPPORT TE COUNTY PlOr REVIEVVED FOR CODE COMPLIANCE NOV 10 201 INTERVWEST CONSULTING GROUP __ ' _-_.... L._ _.._ n __ _ _. _L-1_ _ TABLE s CONT. TU TAB! < ENGINEER TO SPECIF' WE'..D SIZE J fJP YFL D OP, IONA L CANT/L EVER BASE PZ A ,F -- a;nAIGHT COLUMN SWTh DEPTH RESTRICRONS L A N TIZ E v_f, I Or i�IV%N C 'f:,,%,E •'r T„s;LE 2 T,4311 2 E2 3116" VLPG7H PER 0_'"S1011 i 3116 TARLE 2 -IA (7YP.) TABLE 2 TABLE 2 �(OETAIL B -1A B --B CA"•,'TlLl.'✓E;R BASE PLATE ENDWA.LL COLUMN TABLE 2 TA I: L:Il'lallW WS -4 Date Issued: October 30, 2015 3/16 3/16 DET L C -IA 3/16 FULL LENGTH FULL LENGTH OF FLANGES 3/16 TABLE 1 S.A. W. TABLE 1 S.A. W. FULL LENGTH \ \ BASE PLATE END OF FLANGE FULL LENGTH OF FLANGES. UP 12" OF FLANGES. TABLE 2 FROM N -----aTABLE 2 N / J/ TABLE 2 FROM CAP PLATE ` CAP PLATE DOWN 12" DOWN 12" WELD PER STIFFENER DETAILS ON WS -5 p -N- DETAIL C -1A SEE WS -5 FOR WELD DETAIL C -1A TABLE 1 S.A. L2 FULL LENGTH OF FLANGES. DET L C -IA TABLE 1 S.A. VL TABLE 1 S.A. VL FULL LENGTH FULL LENGTH OF FLANGES OF FLANGES. N TABLE 2 FROM TABLE 2 FROM N BASE PLATE END OF FLANGE L 12" UP 12" -----aTABLE 2 C C TABLE_ 2 TABLE 2 ® • SECTION C -C FIXED BASE CANTILEVER COLUMN F_NDWALL COLUMN ABLE 2 I I I I I I TABLE 2 LE 2 TABLE KIPS ,f7 OR J,r6 T �� T = 3/4 MAX PVI 1 1 5 / OR 20.4 I ..(\ T = 0.432" M.4 I ROOT = PER W BEVEL 7q� PER WPS OI I � 1 I COMMERCIAL STEEL BACKING RING DETAIL H-4 HSS ROUND SPLICE DETAIL H-4 4 2PS2 (B -Lia -GF) T = 318 MAX. OR WP46a T = UAL/M. S. ROOT = PER LOPS GROOVE PER KPS CARBON STEEL BACKING DETAIL I-4 RECTANGULAR TUBING SPLICE OR PIPE RECT. TUBE WELDS LARGER THAN THESE STANDARD SIZES MAY BE REQUIRED REFER TO FFABRICAT70N DOCUMENTS INTERIOR PIPE OR TUBIE COLUMNS ANY PREQUALIRED OR "PROCEDURE OUALIRED" FULL PEN 6YaLD MMY ALSO BE USED K17H COMPANY APPROVED KPS. ENDWALL COLUMN (BYPASS GIRT) ABLE 2 TABLE 2 LE 2 3/1 TAB, 7 WELD REQUIRED ON !HIS SIDE SP,EFENERS 3116 `-r,-( TABLE 2 END ✓ 1ALL (COLUMN (FLUSH OR INJSET GIRT) BUITE' C qTy V m� OR m n 0 of 1 •.� c q 0, J C m in '� 4 W �_ lr wzm ®❑ Y3� a z OR " i3b z - 0, ox v �0 ., l h x LL� Qmno t S9 I Ek ¢4 z N v M -W a` tit 00 ❑ ❑ F Ujp �4r if Hoz -P Z >aOn m 000UC U g 000z 3 �zm=i2 F U UNUm Q Scale., NOT TO SCALE Drawn by. JOE 7/15/16 Checked by. JAM 7/15/16 Project Engineer SG Job Number 15-B-39475-1 Sheet Number; R9 of 21 The engineer whose seal appears hereon is an employee for the manufacturer for the mat®rials described herein. Said seal or certification is limited to the products designed and manufactured by manufacturer only.The undersigned engineer is not the overall engineer of record for this project. Ronald W. Bennett. P.E. REVIEWED FOR CODE COMPLIANCE NOV 10 2015 INTERWEST CONSULTING GROUP kr � 13/"is I/ —__.=x567 =__co == TABLE 3 TABLE 1 BEAM WELDING WS -5 Date Issued: October 30, 2015 FLUSH NO VIELD REQUIRED SC1, 57C,9, SC74 t ,�._ ( I J\' • TABLE 2 27TI On sfPSi65� `) • TABLE 2 SEE NOTE TABLE 2 } :N'0MELn REQUIRED / 3f76 � ' '�,.-�..� � - ,9 a � i. 11 � f • SCJ, S^56, SC57, SC27 NCI Fi1:4L11'v G1,R7 CLIP STABILI[ER PLATT IF REOD TABLE 2 SINGLEPLATE CONNECRON K%r_'LD OUT FLUSH W7171 ROD TANCENT AS SHOWN E =0,/4 HIN 2� 1' 4 F—��iE p.!liJ BRACE ROD CONNECTION ji 4 AT Pi o-u,C 14-,�.:..5 BEARING STIFFENER IT I I T7=LPi 2 I ~� AT FLANGE WTn0 T HALES I I it i T !I A:S"ei 2 FULL DEPTH STIFFS -MER PINCH STIFFENER T!,"! E 2 "Pic"i_ SINGL )IIJS OF COPE BE 1/2" MIN. DETAIL L-5 TABLE 3 PARTIAL DEPTH END PLATE RECESSED AT FLANGE LEAN—TO OR END PLATE CONNECTION TABLE 2 TABLE 2 STANDAr'?D HEAR CONNECTION AND COPES FOR WEB 3/8" OR THI:^.KER IP; "Q" FOR WES 51V" ::HICK OR LESS STIFFELILS 'VELDIP G DETAIL FOR &Eii/,1BERS TO BE PRIMCD of PAINTED FOR FLANGE 318" OR THICKER NOTE' IF CONNECTION PLATE IS 3/8 THICK DETAIL M-5 CR MORE THEN WELD PER DETAIL B. PARTIAL OR FULL DEPTH END DETAIL N-5 PLATE FLUSH AT TOP FLANGE END RAFTER END RAFTER AT CORNER COLUMN STRAIGHT OR TAPERED BEAM HOT ROLLED BEAM OR CHANNEL OR SECTION 0 F0,4 FLANGE 5116" THICK OR LESS HOT ROLLED BEAM OR CHANNEL SPLICE /SC1, SCh9 SC74 f_� TABLE 2 SC63, .SC91, SC93 ./ V 3%16 Jh SEE DETAIL K-5 B SEE DETAIL K-5 SEE DETAIL K-5 GIRT CAP WELDING (SC3, SC56, FTFFENERS STi'FFENE'i VvELDING DETAIL FUR IV i✓,'BERS TO BE I-!Ci—Lifr'PED GAL VAN',1 ED ?EQIJIRED A?' ALLOW HOF—DIP TO FLOW P WELDING FFENERS TABLE 2 \ 3116 TACK } / 3/16 DETAIL B—IA —/ '—=� GENERIC BEAM DETAIL 0-5 EXCEPT PURLINIGIR7PURUN/GIRT CLIP CLIP /_(SCI, SC19, SC74) SC272) EXCEPT GIRT CLIP TABLE 2� GIRT CLIP (SC325, SC326, SC327, SC328) FLANGE CLIPS & WEB CLIPS TABLE 2 Ld � DETAIL K-5 TABLE 2 —I—}--( 3116 TABLE 2 V � TABLE EACH ANG COLUMN TO RAFTER CLIP HOLES VARY TABLE 2PF1 OR WPST*9 TABLE 2 S=2m "X" WING PPLAn WHEN UJSED SC2 AND SC280 DETAIL TABLE 2 VHEN USED 5115 FILLET FOP, 112 OR THICKER, PLATE PIPE STRUT WING PLA TE FOR ROD BRACING I TASLE 2 R0D BRACING WING PLATE TABLE 2 X" �/--j�EACH ANGLE �I TABLE 2 EACH ANGLE 4" WIND STRUT BLA T`I"E COUNTY BUILDING DIVI SIOiN AC)VE REVIEWED FOR CODE COMPLIANCE NOV 10 2016 INTERWEST CONSULTING GROUP r II I Ill � "1 < 9/4„ r�r-tc�AL DOON L ANGLE —� T Y,Cr%CAL COPING ! P ' )_'ENING SIZE COLD -FORMED MEMBERS WS -8 Date Issued: October 30, 2015 ��rF�nm rt 1P r�`� or GREATER NOTE: REFER TO NCI WELD MANUAL FOR WPS's „ �s1 a thickness of thinner member _�----�_-- —_— DOUBLE CE" COLUMN S99tE CEE TYPI,vAL COD FORIV PA SE ' StCCitih� A--,4 n`D FORM _P_AF ER ME-;.__S.T'�TENrR do C 'LUMIU CLIP F)P. BOTH P RESENT OR BOTH P ?RESENT _I Y^'Ir_r,L ,.COL UM.N vR R,rDGE— TIE bUi( JUIN! ^OU&C CEE RAFTER 'N;Ct£ CEE RAFTER SC2 70 RAFTER thickness of thirwer member OR CLIP ANGLE SUPPORT PLATE ANTI—ROLL CLIP ON COLD FORM CEE CLIPS AT END OF COLD FORM MEMBER -------------- TYPICAL SLOT REINFORCEMENT TYPICAL STITCH WELDS L .I. LU'' -_.._- OMEP SDE I'JI16V �. 13 ill ElTHEP, n'COF / "r '- lz HALTER CONNECTION O O O i ! O O O LO O O O _DOUBLE DOOR JAMBS / HEADER )TYPICAL GIRT/PURLIN CLIPS REVIEWED BUTTE COUNTY a Y FOR CODE COMPLIANCE BUILDING DIVISION � `"� g �.�'® E NOV 10 2016 At (z P, "^`� I � , i INTERWEST CONSULTING GROUP i#, .circ, r�r,r=ndr 23 Inc C' n. r -+n 6, :7 EEO._ .,,:,h Il a �/- P'dsi SGP (When Re ) note- ul Roar Pia: 5yrn%d ]h d Pt div (¢) Column I Slem Line (2) goes Unless Sled M e—wise On Erection Dmwinge I Roliar p{ (4) Dolts I With Wash rs , Caiumn I Ali Ea*s To Be 3'' UMes hc.e.d. t E q eIred U , res. T hip 4" d Ta ua On Errtboc „r..gs. hen»A Bolts Bearing lcragmR Eldw all Inside "c a a, in> Ex e tsion to Bridge Channel �'eg° eV EF07117 SeC,en Lou Side Eave S. ... and P, dir (Roof Slopes 43:12 Or Less) nn Data Flush Polar 15 �0 /-- Pudin Pudin Stmt (When Required) Denoted On Roof Plan By Symboi -' is s^ Bridgo Channels /' Eaw Strut /{ (4) Bolts (4, Column Steel Lina (2) Bolts Unless Noted OGrerwiaa On Eradkin Oraw!ngc Rafter (4) lsBaps Wt% Waers Column cKnwvicn A Butts To a fit Unless Noted Scotian ^A" Ft Required Length Refer To Gdp —_ Tele On Erection Drawing& Purlin to Rafter __ r Standard Connection - Flange Brace FB4_ rection Nate Lap and attachment o! Purlln varies refer to Roof Plan and Lap Detail for requiremeMa. Purlin Lap Symbol denoted on Roof Framing Plan on 0 (2} k"o Bolts each end of Purlin lap 3 0 D J"0 A325 Bolt Flange Brace each end. FS4_(when Girt Connection At Bypass Column nnel specified) Pa9CF01120 Data RB, Attach Flange Brace to Rafter sops CF01121 and "Field Bend" to attach to lower Purlln web hole located Affe hm t Jan'14 132 2'-4" from center of Rafter. Erection Note Its Flange Braces may be required one or both sides of Rafter. For requirements, and locations at ••_•~- _�-.� W, r I v. Rod B i A. s,'oAy -\ Se: era on D, ve;r'as for I' Main Frame and Rigid Frame In Eadwa!I refer to Cross Section For requirements, and locations at niqu red cart Mork and lc,. -a n. Bearing Frame Endwall refer to "Roof Plane. ------ .__.._Rod Brace nom. Attachrsoent at Web Ja Rod Brace (See Erection Drawings for Part Mark and required location) 9nor threads after final tightening Slope Washer l Not meso Items snipped Flat Was"her � Sea tableblebelow for Hez Nut EREc-nON NOTE OFTAIL AT COLUMN SIMIIILAR AT RAFTER. Far Rod Breaking that falls within the Girt Viet„ the Erector is to Align slot with add c minimuum site slat for Rod area!a� the passage of the Rod. PART MARKS FOR ODD BRACE ROD ROD SLOPE FLAT HEX DIAMETER BRACE WASHER WASHER NUT J"0 WROS__ WSllO WFH500 HSN5GO J'0 WR10w511O WF -1625 HSN625 't ;'o WR12__ W'S120 WFH750 HSN750 J"0 win 4__ WSI20 WFH875 HSN875 1"o WRi6__ WS130 a 13001 HS"a COO r' si ale t, evf ed Rod Btace PF04113� GirtPogCF61115 Cee to Column Girt Connection At Bypass Column Pa9CF01120 Data RB, By -Pass Zee installation sops CF01121 Affe hm t Jan'14 132 Standard Con �eakion Jun'15 00 Jun 16 02 ••_•~- _�-.� W, r I v. Rod B i A. s,'oAy -\ Se: era on D, ve;r'as for I' c niqu red cart Mork and lc,. -a n. g rppp. Column 6 note 1 fly r,.� Tumb kin included cr ,.e i �� k , � f �/"� / (2) "0 Bolts at Each end Unless Noted on Erection Drawings (2) rO Bolts Typical at Connecticn. Bolls when f (4) not B G rt Lap , Denoted With Symbol }rs,( on the Erection Drawing&--�q�— i/4"- —` -- y Aa»w^m l) rly even tR i endo a' R d are GlevkadJFi��rl�. 'A r%�, t % (2) }"0 Bolts at each end of lap { — — — - v'' / Ed w. h t'ax Nut r' A'25 z 18" at ro 8e ro `:ed f �'0 A >. % 2' o, q"4 Rad i � { Ld `y¢p JI ! Section A TdonglC PDowc Points In Dir»ctin Of Large Flange .a e A52. z :' at #"0 & 1"0 Rod 1 J A..c5 ,. 3" at 1z"0 Rod �, --.---_. (� � a f I C Zea Lop F _ T IfM11 +. Outer ZeeGirt Flonge A { Channe; Girt 1 ,. 1 ^oWn V s P otc ` J Inner Zee Girt `\��., S Pairer or plpaj7ube SWt 1p �--.� L Column Flangge Flangd n. Chsr,rr# (, r< �� Factory Welded Clip w CE-yFrnme-CLFrnmee r Far Rod R.ocing that fdh we in the Girt Web.t E. ct r, to A17gn s:ot with end I r r -. C� add a mfn»n..trn t ze alae for �`` }� / t: a a nage of ha Rod. ,:jr - A'Romoto Correction -- i \ Column (Shape may Vary) Refer to Erection Drawings for"----- Girt Lap Symbols and C101122 The large leg of the Zee must be alternoteed from top for Lap Symbols and Lengths to bottom in to the member ccorrectly. A order nest triangle has been added to the end of thef Zee near { , the connection holes, that will point to thee large leg of the member. IERECilcN MJTF Ci AP A'COU H4 AND q SiellLAR AT YiA.A�Fst O4 PIPFj'1 Pr S7F . ii \ % Sactia[I_�_ All Bette to be Unless Noted -- ---- --- --- y '-' Ford Length Refer to Grin Length Tablee on on Erection Omwincs. _ a � � I�' REVIEVVEU I DIVISION FOR CODE COMPLIAN B WNG ' 0 ' Nov 0 2015 INTERWEST CONSULTING GROUT 'I I 'II fl � I' � _ II �, e O C E o u o in o a ®rt o u in b aH ' aI ti O " gz;rw,U Li wS -O ° yy is V G P E e T zN 4 4 O m 0 F w 0wico H zaa`Z i o><2_ 0 C UOUO a oOUOZ•E� z 0< q �Om2>r s U UrNUm O Scale: NOT TO SCALE Onswo by JOE 7/15/16 Checked by. JAM 7/15/16 Project Engineer. SG Job Number 15—B-39475-1 Sheet Number. R12 of 21 fie engineer whose seal appears hereon Is an employee for the manufacturer for the materials described herein. Said seal or certification Is limited to the products designed and manu`actured by manufacturer only.The undersigned engineer Is not the overall engineer of record for this project. Ronald W. Bennett, P.E Girt Pnd fur, Coirmerfion At Byposs (Cpl .'2m;ind I Wier It— g ce of p I Girl a fe?In ➢ac Yte c� c!Ip -� i{ t- (tl �? its P"t"y 8s ed Clip ,:r or RdeA ;. �j itr in Ro'e:" e t c 8 Lap x-IbaE �, G 1 i .-51' az 5417 k 1'-51 at t7 2-5y c6 <?1 a 2'-c')' ori � \ p a- <3> 22 6 Guns it Column 1e, 11-1 Flush Siidevall or End'.:rali Mtp V li L (4) 3"p Salts ii (2) }"e falls a' oath erd of lap f Girt N °unix "�/ / i-rj a -4 Buts Tlipical at Connection. Fx;an• tYaided Clip -/ y 0 Sit when CIll or pidSn Los is ` II reretd anti S+l,ai ,* the ( t lump w Rafter I ¢r...7orD.cerg-. Lap SY"!ba3 <T'._.-_ 1 R ^VN Rafe- to Erection D.ortng s for Lop ',;Thal ct Girt and Punta Coorestmr. 2U SECTION LAP TABLE 'MBOL LAP LENGTH SIM' LAP LENGTH Bolts to b. n 4 Unless elated. O Q1. Y-5 rt Ai! ? E Far Required n h Rema to Gip Table an Flectiotion Drawings. CL292 oI .....,_ Shooting Clip (1) Pester, #12.A 12-14 x 1' F.H. DP3 at each and Eave Strut Connection at Main FrameCF02030 Eave Strut Connection at End Bay CF! Interior Bay Feb'11 p®1 j Bypass And Flush Girts "feb' /-Roof Line `r Roof Line /-Roof Line�Roo, Line 9 V T b 4n rn y �2 v1 on v m c i m o z 2" �- s W 2" 2" 5 x LLi 2" 2" z w 27 2" t � �lca i5)Girt Depth + N 1 Gir# Dept th + i/4"� N i -By-Pass Flush �y-Pdss Gt Flush Girls Ct Rafter 1/4" 1 1/4";1 1/4"' Roof Line / (4) 1/2" X 1 1/4" A325 ' Bolts without Washers 0 Eave Strut a,I Eave Strut Bottom Flange J N N'Or..Ti_ Steel Lire vl ; — (4) r6 A325 Bolts BayI Bay Varies Column or Rrafter End Bay r t C d' t- ' So,.wd Clips , ra"tT^.d 0 en.ii Connections AC01320 Bolted Clips s •Framed Opening I a pQ.ln w,.. F,ntl .ot Sac - $J clip cFczo3e p y p Op g Connecd ons AC01323 Balked Clips •Framed Opening Connections AG01324 Fit Patter � ���;AG,14 a�4 Gold Form and Hot Rolled Gee • i6lree anal Four Sided Openings 5 -a '14 ®2 Cold Form and Hot Rolled -Base, Girt, Header, and Sill to Jamb IM °14 02 Cold Form and Hot Rolled "Jamb/Sub Jamb to Z±oe Girt Ju!'1i ®0 --- — g ?: Boil Back-up C� +ate; All Haizontci Members within S p 9-' ;lea- Opening are. Capp and attachez Sa Roof t'emn'9 A ',a Jamba with JI Fin read P c SC425 Clip See AC00Qt5 thru ACOOg23 SC425 Clip (2) 1"6 Bolts l Pim jr Loco .n Typ. at Hsadw and AC01324 thru AC01332 g0 f B pu s Puri!n Horde•' (2) n"O Fin Jamb/Sub Jamb t° Girt within opening Is " Hole Location, from face of Cee S"92 of 1Q our'-„ \ f F.._ if.et Rolletl% Head Baits (Cold Form Shown, provided when Framed Opening *i}" Cold Form GJ-, use 111" EE pf Q:i=('aid Form)I ) is to be paneled over. "-'I Hot Ro!!ed JL &z .Y2_ use 111" +Web Thickness g ci i Fi.s a 6 Hot Rolled Similar (2) 1'4 . ,S" --` ; ' ( %e ACOIJ23 —Jamb/Sub Jowitt A325 e a` )ir Header (Cad Form Showwn, s ;c Opening Width Hot Rolled Simllilar Eraouon Draori tro 2 e/Ca_G t "" a¢ Cee G''t Zes Coe Grt (Cold Form Shown, Opening Height lamb/Sub Jamb ) F ___ _ e ! Hot Rolled Similar @E nip '\ �. r 2 / - — > (Cold Farm Shown. CL751 CItP 1 y \ :rt CL751 Clip Hot Rolled Similar) 1 Y See ACo1323 �(2) 4"0 Belts CL751 Clip - a, "" Girt within opening 4 i�)'A' 4 `' t �\ Tyy. at Girt 1 _ Girt - Zaire Girt *'t$ Rafter rn� I I g Opening Width I (2)"m Bolls (z) 3^a Baaa t4Tt - ^..,` //� a Jamb---, fr Jamb Header to Jamb 1t5tit \. p' _ t `R_. (t'.ax P ',td JR_ (Hat P.oilod) ��- ,-...-"a..'° ' j GJ-, am) 1Cald F DJ- (Cold Farre) Girt -:i`ll 0. 07323 - - t a I s Haigh lei nt See ' ---� Fin _h flax Ii_. Opening Width Girt t (2) 'p'0 Bolls ` — �— — Field Drill 16 a Hoes m Girt all (2) rO Bats _�,Y I He B FIs Field I acted Framed Openings Opening Yf:Cth _ I SC425 Clip Head Bolts N .11 r. 6 -•J �Lr fff------- ------iii ( r Sr floc., oming lraa3L.!;Li..�d-Alm11 Sill -Jamb/Sub JShno / (Ct!d Form Stovaa, / "" C,;r* w i., e,renl^ is Jomb Sub Jamb Girt to Jamb 04757 Clia Plan for a^atar g (Cold Form Shown, / , Hai Rolled .nm,ilar) L 1 c Rafi. / crn0 a, g n,ir _,s Provided when Flamed Opening B Fs;i Sa to Cs naiad over. SyA2' C•p-' Hot Rolled Similar) Hot Rolled Smiler (cold Form Shown. G 'f2 g s0" '1ilY:E Pa' r1D at Faaderf5111 \0- _ 'ea RCd0975 ihru AC00923 ) SC94 at '12, porton `/ ,"rand A101324 thru AC01332 Jamb,/-;t!;h Jnnb tQZze Girg x (tool Raid) Sill Height 9 25 Bc t GN 'Cold cc m) �� S`.5%'i Erects Al triol on I Hand"0 Fin Bolts CL753 at 0" j E I 1 -Set AC01323 I Erection simian, L 1 ly I er_/r C I Z Csc G1r4,L Zee/Coe Cee Glrt .:' / !� (2) }"a Bolts I Jamb/Sub Jamb / " %' 1---- - (2) }"6 Bats CL757 L p iz" c l 1"6" O ' (Cold Form Shawn, .>, Flsid Drill 9 Holes M Girt at Cad Foran Jambs Fid Locatod Framed Qpenings Hot Rolled Similar) Cl Tat Gip See AC,01323 i Zoe Girt l� U tl ( a F- et Cvi $ At Cold Form Jamb Jamb/Sub Jamb y ,,, i CL751 Clip (2) }"0 Fid Bolts at (Cold Form Shown, I, p TI J k- ._2 a vi' CL751 CII SL Three Sided Framed Opening. Hot Rolled Similar) li Girt , /� Girt r Zee Girt 1. (Hot Rc!lad) w (2)"0 Bats at Haight / Heigh, ( ) Jamb Opening / c� 2 tl Bolts r Oald Fcrm Four Sided Framed 0 enin JL -(Hot Pr'ie6, JR- (Hot Rolled) z �m Anchor Rods J 'J Field Drill R"3 Holes In Girt at Rolled) _ O O Jamb Sub Jamb OJ�Cob Fam) DJ_ (Cad Farm) n) L •_\` __-_ (Cold Form Shown. 1 p I �i IField Located Framed openings 6 Fafinr -_ ramieFinish Fne �� Ian. I Ha{ Relied Similar) in ( �a �g�tenOsr 3" � ! t See AC01323 21c" kmIn410Jr! nL i � 211. Ij }" Base Plate on JL & JR do G;.an ng Y,rdI thru AC01332 Hot Rolled Jambs I e is leo G'rf d�mn.� iJam4 Ea;:�S!J�zLFicaacd..4i�filog. JRa12.1a�11sh Floor I P -UI D1t,!G DIVISION sf. E a m'' REVIEWED FOR CODE COMPLIANCE NOV 10 2010 114 r w-• CONSULTING GROUP 0 O C G E R$ a- c ,O o- so 06 `o O 0 i � mm�aat, oZ4m 4 4 •p; c Awa ElrjK CSI ' ZU W O a5r �nb Y .. C oV �� oa �. ON ❑ ❑ U :aBr, m no y, 0 to>az Oo V O Z ann 2 Checked bac JAM 7/15/16 Proadt Engineer SG Job Number. 15-8-39475-1 Sheet Number., R13 of 21 The engineer whose seal eppeom hereon is an employee for One manufacturer for the materials described herein. Sold sell or certification is limited to the products designed and manufactured by manufacturer only.The undersigned engineer is not the ovemcl engineer of record for this project. COI,d'` or1Yl gird Hot rolkd Clad= - Fink.iing BCbtiOPi.i."afribs eL•/Sun ,iamb <` Fane 5hc•-rq • eailod simtar; F;,ISt,ee!tna Atic 'ride vit ora Attr";h ricin 12) Ferhx:cr 412A 12-".4 x 1" P.H. 03 at Cci<: form Jamb and (2) Fasteaer 415 12-24 x 1}" P.N. DP5 at Hot "%..lied Jamb ^' Cifn with 'W Fill Head Date Jamb/Sub Jamb (Clod Form Shown, Hot Noted Similar) RAI Sh.zting Angle Field Cut and Attach eld, (4Y Fastener 4113 4�14 x 14" i OL751 Clip with (2) ja Fla Read B:dts i- Jamb/Sub Jamb E tIcbl Fom Shcw% iy Hot refund Similar) %.-Girt Attached with §"u bon Knock Down Wa! Boor Anchor Pl7cement 2 i/2" Smiting -' Nl ch U required _ne _ — __.__-- --------------_—.__— AC05130 Knock Down Walk Door With Jamb Extensions AC05131 T Date R. Single Skin Wall Panel Outside Closure Requirements; at Eave �Danr, Proles />- 1/2" uta. ease AnchorsE (prcvided by door o Q o manufacturer) u- _ ' `o N is t�5 t3 —///•—Yiiri"'YYY r titeal Lena The adequacy of the 1/2" die: base anchors provided by the door man,, ue.r r ,.a rotf t e rrs crs!bchr of the BuiIB ig Manufaatuer. Tie ad..1r rcy of these hwi anch is should be determined by a qualified fcvan3:Pio" epL3ne i. With Low Girls Attached to Door Frame Mar -16 02 Foam Closure PER GM Ba AVP/ PBA Jamb Extension SL s„ (See AC05138) Eon, Stmt HW460 VistaShadow -- See Note J- FIVA24 P3C HW462 PBD HW'463 Eava Trim HW412 Jamb Door Frame Jamb (Profile Varies) Extension RBI) (Reverse Rolled PBU) Jamb 90 Extension Fastener r2A I 7.2 HW461 12-14 x 1" Cm I. Z10 ®❑ Pancake SD w Door Frame Jamb W/0 Washer (10 Req'd) Outside Foom Closure Low Girt A Walk Door Clip U (Sae Chart) (NDCB,K^JCiO,WOC1?.) c4 F Jamb Extension so_ etre Z ON Walk Door Anala (WDA) HM582 for 8(" Door Frames See Detail B. aced to Woil Panel (See Chart) Field wt Brace Strike Side of Door HW9876 for lOr Door Frames Jamb When low Girt at HW9877 for 12)' Door Frames A Girt 0ewtion 2'-6° thru 4'-6" 0�4Zh is not Present U 000 U Attachment to c ZnOQ Concrete not by Nate: y Metal Bldg. Mfr. If Girt has a 3r Flange Field Detail at Foen C'osu-a Notch Jamb Extension Channel (Low Eave Shown High law, SimAoO W Clear Girt lip. Do net Framing Elevation Notch Girt lip. L r Girt taw Girt Fastener p12A Field cut at 12-14 x 1' Panrake Door Frame Jamb SD W/0 Washer (two an Each Gkt Door Frame Door Frame J �� Jamb Header section B Sect A �H�- Fastener /12A Walk Dow Clip 12-14 x 1" Pancake (WDC8,WDCIO,WDCt2) SD W/O Washer (two per Each Side of (2) Fastener �y113 Strike Side of Door Frame ;-14 x ij" SD W/0 Washer Janb leg} WDA Strike Side of Walk Door Angle Door From. Jamb Detail B 1 -all Panel Foam Closure PER HW'456 AVP/ PBA HW465 GSC HW460 VistaShadow HW465 Nu%all FIVA24 P3C HW462 PBD HW'463 Stiadow.Rile HW412 Designer Series (Fluted Only) HW4D37 RBR (Reverse Rolled PBR HW455 RBI) (Reverse Rolled PBU) HW459 7.2 HW461 Eawe Strut Eave Trim (Profile Varies) Outside PDR Metal Closure HW429 P13P Wall Panel Detail cot Da R Pa Metal Closure Fee FOR Panel Only Farm (Law Eavwe Shown High Este Sknilar) r t,008003 Forrined Base Tfim FWU2010 PBR Wall Panel PW02107 PBR Wall Panel 'PW03001 S'tgi ; SMn VVan Pine! Otat;;lds U Isu:e Rr quinaments at :cake cr- Rev , F73 Formed Base Trim Without Panel Recess °ate iRsa Outside Corner Trim °ate ReO e "era I IvoV'15I 00 C13i8i1S �eQ r10 QO Ocet'14 00 Mav'18 08 Rake Aran -� PAI �4 F- Fnrined Rage Tris;x 28'D" (=rri,�a1 Rahe Trim, f=%'3, sq,ure cu-L2 at Loth ends I G O m Outside room.annu-/ Ese Curt and Mo?A W_7 Pcoel -� r", Chrh' t_ . PLILII_e�. Rake-A.nye A9 R,!v Tran (Proele Vw'. 0 FOR 'Nall Aside Meta! Closure uf429 or 4W429A lode Mote $a) D.ta3 nt 0 L-- a? Me4Rl C_m For PER Pmol Only E t.,; 0ats7Pz rand ,!es - yea n r•_ sulrN at ti ,ted .. .ai 2 . LR Well riorel lase a f'c ' . F c t d fici P,10 zirle 4A2 r rose and HW --22 far R R r Slope Gr s.ren 4:12,x,ai r '! n s4 o Pm.t Po--. 3�IR41 e Cur,ce! h%tchi fv R t yi&01,Thr dp+2and 9'l40A for co, b v ^tor'" n Zj 2 n° a 41 AP Ftkc 4dn ,M R,j,d,4d fr ni . -rid p 4 cu `v m; e, Sate Evan Reef Pard „al.." let 1^^u' -Oe :''.3ke A1Yyl4 fiAt Eike ( rad. /sae Vo. C, rds room (I., S a:n -% . Metal cunt.. t Cctrioncd �" Pare; -1 (PRS Civ jt Tletall at Rake Sik!e Rine out to cut of concrete 9 i73.._ _ F73 I °h' F73_ —Svild•ng Slob-� M � �4 d Fnrined Rage Tris;x 28'D" (=rri,�a1 q o f=%'3, sq,ure cu-L2 at Loth ends G O m Edge of slab M is' IPrT� `o! >lde Fle. o w� C ning ^'I cope ?: hoz 9 UseA n) rkh mI ' Aenosmideleg Concrete is 7al caaOmmMded. MG I ' Corners 2 Attac mel: of ',[in to aaee! by tl a 3. F m,3ll Lasa ,rhn Io p,airdad in -- 20'-O" lengths (sial.), field s , i73 �ig2, dui as rsy''i. .2.v' Out to out of 0:tt to at ci mncraia Concrete famed ase Trm .metI L'd OUt s/ 1" /-I/A" Cu. Anchar (alin) 11` / at me O.0 (,Ih) NW1112 7- t no+ Biala M i \ji i . /~) -Fastener 14A a�l��ra ., � Vtz1/g" \ Ca^err„e :.�—. �� ,; .� (2) Required 1 7i3° � 5_rtion"A"-Ilmmed lies, ?yp_cryl Cvt>ide Corner P.nolicanon PBR Well Pane! Fastener #17A 12-14 x $" SD W/Washer 5"-7"-5* O.C. Concrete Fastener }"d Minimum Optional Foam Closure S -O O.C. Maximum H,8455 (Not by Metal Bulking Mfr.) Formed Bose Trim F73 a PBR Panel Field Remove Bearing leg as Required Corner Trim F830 or F652 Fastener 04A J-14 ex I" SD W/Washer at V-6 O.C. Fastener #17A 12-941 x 1j" SO W/Washer a: Eacct Girt Steel Line PBR Panel Steel Line and q Panel R BUTTE r�IlI��' 13JILDI j,);Vi n0N REVIEWED FOR CODE COMPLIA NOV 10 2016 INTERWEST CONSULTING GR a v an, Q U G The engineer whose seal appears hereon Is an employee for the manufacturer for the materlals described herein. Sold seal or certification is limited to the products designed and manufactured by manufacturer only.The undersigned engineer Is not the overall engineer of record for this project. Ronald IN. Sennett, RE q o btu � k$•', G® G O m 0 m� & N o _ Wz Cm I. Z10 ®❑ S w c4 F Z ON U yy��> Zan ¢ as A ¢m N a mZ O 0�4Zh U 000 U a 0002 c ZnOQ 3 U 5NOM O Sca/e: NOT TO SCALE Drawn by JOE 7/15/16 Checked by. JAM 7/15/16 Project Engineers SO Job lrumoer 15-B-39475-1 Sheet Number. R14 of 21 The engineer whose seal appears hereon Is an employee for the manufacturer for the materlals described herein. Sold seal or certification is limited to the products designed and manufactured by manufacturer only.The undersigned engineer Is not the overall engineer of record for this project. Ronald IN. Sennett, RE _I J I . _ _.... _. _ _.. ___. _.._ _.._ _._. _._.__ _ _..._ _. .a _I_i_._ Pie„ a Fw1ie6 ___ DPen tIfa,l Wine, WTI Fr e o 'i'A t c rt 1 0± { �.- orn was Wm I. Op-, 4'iai? Coraar F1:3 , Menber !'2950 8 1,'2 Atambar F411O Member F4111 i2 tAsmCar Foetenar. p17A 12-14 x '1J• SO W/Waeher m oath Ort Fc:-Auner #^.A 4'-14 x J" SO W/N'a=.her at 1'-,0 C.C. HR SIMM panel Panel @ills Lap 1-14 x J" SD W/Washer shaoting DKstiv, at "a O.C. C ehD.�FL( J-14 x J" SO W/Washer S�.mt:�!rir�y D,,k dxdc��' ^n mat 1'-8 o.c. :YI 0NC Paye. PBR Wall Panel PIN05009 Fastener Location Det° '�e0 Aug'15 0 a See Note Ji 7" 5" 7" - 5" Note /1 See Note #2 1'-0" 1'-0' 1'-0" Fastener #17A 12-14 x 1J" SD W/Washer See Note N3 Sleeting Direction Note 12 Fastener R17A See PWO5011 far Panel End Lap 12-14 x 1J" SO W/Washer See Plate pt i'-0` O.C. Note 13 ' Fastener a4A x J-14 x r SO W/W..her 1'-8' O.C. e Eaux Simi Wall Girt Wall Girt Well Des s Note $2 a Note g2 Note J7 PER Roof Panel Fastener a9 and Tape Sealant Location ip ; _ 12" 12°_ _12" 9 1f2' 9 1/2° S 1/121- 2 /2 1/2" I 2 1/2' Shaving Direction See "`GOR04016" All Roof Members Except As Noted Reidow iT 17" i7" „'"""°y "••"'•• Sea "VIWAIU16- Atf Strut. Panama 'f'nA_W and alk Purlin Nate: Screw Patterns Shown Satisfy U.L. 90 Requirements For Roof PEP Panel , TPR0401u PBR Patie! GPR05001 PER Panel �PR060031 PER Panel 6PRO6004 `�ssss: Lag and End Lai'H letai s tdov 141�0s Peak. Box Feb -16x04 Fixed Ridge Detail Nov'14 e02 Fixed Ridge Detail Nov'14 02 4he t ,a alreatb� I rc Fastener N4 a�J 4 x {' LL SJ W/Washer it A.1W1Y•7 tie^' \� s _T a'at a' O.C. ' i N O.C, d V"—..._ -;.as .ealer }" z" gpe c uer F'N5O7 i 56, �j� t «._"o _...✓ O--"[ i/d-ta x j9� (D) Fastener /4 0e,_ -%✓ (Rose to Pee. D^x) x J° lL SECTION THRID oA L SDEI AP -Y ./,. y. � SD W/ E41 1 � Two Contlr.urus Layers , t f'al¢jria• III xosk oz Rahe Trdn Faciae� 13 F52 12-74 x LL D e i Me F'tmed Rirt;'e Cep Tape Sentra x gg i r Platens pH Hv.�so7 f r—i 'a la. o sD W/%aenr a'+/ -I ere sym. !f n'1RaA'sherl.l. -- I I ij rmatenc U WJS e JPS y\�' 3 1 _ OR Roof Panel at r Jr 14tx L % /��F�,� ya Feet. JA Tape seds, I R"uS -- i�1/ -11 O.r,/8" LL M W/Wosh r i SD flfYn Par / { 44 .�,/ �`r _ �'`� Rouf Pond ! Ta,,e Sens e at M1'-8' O,C.I /.." �1 v= �r"� /-PurHn v r- r'_"� .%�a„ slrem; L b' piece of Tope Ssder T_or S Ax;ran .yasurs by ;" MN!memY PANEL SMA* DE'Al1_ n, WY,' Ers_ PANEL ENDLA.P DETAIL ��__�qq Ea. Slut J - ins!de GWears 1sW455 cel h Tape Ss,, ,s i` x AV HWE tot, and batton ra Tdr. ' eren ngoy rec - a t -bvent Wo". . !n to. n, Roof Pana s; nT Pork Sex --� (Sze Rection its" is Pk. Narxe) Faetenm .MA -"""'`_l 7(h14 x 7/8' 8D of ankh F'nsni If, vin,rn Ja rn.. PIa e, S+.D„j, �.9 hzml a I .y F1 10 _etc 6�� sl vl r Doff qd F, Ira t`. _ 3� r0 f_ nooera FJ FMing pra lie may "y dg7endopt span prod a. Ruc0r.1x3 as pbeteetad one rplA`.w..ie f, off ern \\ N -Roe Anole `Fcebos` A17A i2_1 4 x 1 1/4" 5D %/Washer 44ift P. -t Cl,,..ure up W 412 R:3 •PBR• J����" \� Peds Perin, Roof Pend //�//�\ Surfer HW508 Peck Pullin 13U��Lo�ry A11i o 1l R DIVISt N, 1;fED REVIEWED FOR CODE COMPLIANCE NOV 10 2015 INTERWEST CONSULTINr- r_rIn11^ The engineer whose seal appears hereon is an employee for the manufacturer for the materials described herein. Sold seal or certification is limited to the products designed and manufactured by manufacturer only.The undersigned engineer is for this project.. t g o o m 0 9� o V u a 0 0 z y N LOtt?i o a O1 F+ �v z z<0< L7! ❑ S@ U ow S es• 4 .a �b0 • 4Mwno d 11! ss� F P3 I > IS V O ON zu _E}En { e c RVQ 00 O ofan K a W z4LoZ O C' h U0000 ta o O7Uan O¢ 3 n-_ � 0"000 V CJNUO] :1 4 Score. NOT 70 SCALE Orator br JOE 7/15/16 Checked by: JAM 7/15/16 Project Engineer. SG Job Number. 15—B-39475-1 Sheet Number: R15 of 21 The engineer whose seal appears hereon is an employee for the manufacturer for the materials described herein. Sold seal or certification is limited to the products designed and manufactured by manufacturer only.The undersigned engineer is for this project.. PLE Ught irans,r...as.-I Parol Assef:lhly tion U. n=„ A1„oli .atlon So rwl, Ina tr onl n•! ttwa,lrnw witn by .rd__:s-'o. Fastener :4 --. \'- / 3D T/W7aher (S) 1/4-14 x 4" L / at �h End Lap vi1 Natrh top f!ang� F Fastener #14 er Fast Fastener p4 4 11�^ Al ,�-^ ..- I / i r x Tope Sealer saner Y4 2" O.C. max. 54 x 4" Ll (7) at Standard Miter l Rake Trim S7) W//washer Swell � (8) at Largn Rake Trim Te �.e —S, -r I h ._ � ErdaF- mei; Layou, Fastener i3 l4" 30I F _ ij - tent x 4" SD W/Washer 3" O.C. max. (Trim Color, For Placement Sea Details Below) 12 14 x U. - Fastener #4 4"-14 x 6" LL SD W/Y/osh»r SD W/waaher (3) [ a+ Mid Ryan (Show'.) F f 5,ft haver. ,2T` # 3" O.C. max. 'C F \� \� Fastener #17A at 1'-0 O.C. . -T:: \ p.- f \ 5' sOL (Opposite) \ ..r Niid Spin^ Sc'��v-at/cul F2R Light Transmitting Panel (CP) Layout Ncn U.L. gn Application ' p 2570? �! i2k..h'• m o a S al( ( x o Refer to GOR250031 a I n �" / f - �))E Ifor nsu!�tion lap %l% r� �. S,R J r 1 End!i pl si` 4 � � (ftrl � �"- 15 -Member Screw 3'-Q- .3' -,Jt' S'-0" 3_0" 14 -Stitch Screw 30Lf-1" Tape Saa'ont Shf>c`,ng Limcli- 1. Place roof panel #1 in position and attach to roof framing with member screws. Before panel #2 N positioned, ! stall tape sealant along the outer edge of the panel rib on ponlel41 The tape sealant should always be po,i"ione,l to the outs dGe of the pm el rib so that water cannot seep into the pane lap and the sti dY seas do not penetrate the sealant, which will create a Void in the seat. 2. Place panel #2 in position. Secure the panel to the roof framing with member screws. DO NOT place any member screws on the end lap where the M (` t :t(I Y .^ 1 .. e". ). c a''. !' ° �nr 1 5 mP.mbP.( Light Transmitting c,e w. b, i�.,l,rsr-d Do no" I tel the lost screw at the Bove. This screw will be installed later. Apply tape sealant along the end of panel #2 where the Light Transmitting Panel will be attached. DO NOT .APPLY TAPE SEAI.AKI TO THE R!GH1 SID!' (IF THE PANEL. Do not fasten the panels together. 3. Place the Light Transmitting Panel #3 in. position. Attach the Light Transmitting Panel to the roof framing with member screws, Leave out the lost member screw at the ponel end lap. DO NOT attach the end of the Light Transmitting panel to the roof, member whsre panel #4 will be attached. Apply tape sealant to the and of the Light Transmitting Panel where panel #4 will he positioned. DO NOT" APPLY TAPE SEALANT TO THE RIGHT SIDE OF THE LIGHT TRANSMrfnNG PANEL. PBR Light Transmitting Panel - Lap Details Non U.L. 90 Application Fastener #3 12-14 x 14" LL SO W/Washer 6 at End Lap Fastener #4 1/4"-14 x 6" LL SO W/Washer at i'-8 O.0 Tape Sealer HW50 LTP Flashing F75 or F76 Vinyl 4" Light Tran: Panel Note: Strip 4" of insulation from vapor barrier and fold back over purlin.(Typ.) Fastener #3 12-14 x 14" LL SD W/Washer at 1'-0 On Center Panel = Standard LTP = 10'-8. A minimum of 4" is required for a panel lap. The LIP may be field out or lap under the up -hill roof panel, 12" maximum. Note. Fi 14 Cutting Licht Transmitting Panele Light transmitting panels may need to be cul in the field. H required, follow these steps: • Up to five (5) LTP's may be cut at one time. • A circular saw with a 24 tooth per Inch blade, will work best. • Cut slow and allow the blade to work without excess pressure. • Allow the blade to cool between cuts. WARNING: There light transmitting panels are not designed or Intended to bear the weight of any parson walking, stepping, standing, or resting an them. JHE MANVFACWER_DMJAYZ Au•> WARRANT' OR REPRESENTATION EXPRESS OR W-LLF(t, that any person can safely walk, step, stand, or rest on or near these light transmitting panels, or that they comply with any OSHA regulation. PBR Roof Panel - Signature Southern Standard andi Southern Large Gutter - Sheeted Wall Fastener 4 Note "at"-�— # Screw mustt be installed through the Tape 4-14 x �' Sealer to eansure a water tight ccnneat!on. LL SIDW/Washer Tape Sealer HW:506 S" Long Gutter Support PER Panel �d L - Section A Gutter Support Standard F893 (shown) Large F3357 attached with (3) Fastener #4 4-14 x 6" LL SO W/Washer (See Erection Drawings for Sparing) Eave Gutter Standard F46 (Shawn) Large `3830 Eave Fastener #14 4"e x 4' 3'-0 O.C. With Closure Fastener #I4A 4"0 x 4" V-0 O.C. Fdostener #4 ,--14 x 6" LL SO W/Washer cut 1'-0 O.C. Feaster., #3 M-14 x 14" LL SO W/Washer tat 5 7"-5" O.C. Imside Panel Closure HW455 ewith continuous Tape Sealer HHW506 top and bottom Note "A" #14A FFeatener #17A. 112-14 x 14" SO W/Washsr Outside PER R 1of _ � p � ri i 5 1 Eave Gutter En Lap .nstalla.lotT v PR04002 _ PER Root Panel . Southern Standard and Southern Large NtPR04004 IM :t pro IIW. dta,r'95 LOet Eave Rako Corner uilth Eave Gutter -1d" Wall Panel 51a y'16106 PBR Panel •Southern Standard and Southern Large Signature Rake Trim •Sheeted Wall MPR05002 Mc PM Ma '161 O6 PBR Roof Rake End Lap Installation -14" 1 VVtfa"1 Pznell FJRPRp5010 Oa;n Prr. ,Nov '14 03 Natrh top f!ang� F Fastener #14 er Fast Fastener p4 4 11�^ Al ,�-^ ..- I / i r x Tope Sealer saner Y4 2" O.C. max. 54 x 4" Ll (7) at Standard Miter l Rake Trim S7) W//washer Swell � (8) at Largn Rake Trim Te Fastener #4 4-14x6" L1. x 4" SD W/Washer 3" O.C. max. (Trim Color, For Placement Sea Details Below) 1 „ry ] �! J/ s""" \ 1 "^w.. j l"^�•. F O1 ( Town) Roc Pcn¢i Prater— #4 REM (Opposite) \� f 0 0 C. max. 4-14 x 4" LL Lerpp SD W/Washer Fastener #4 4"-14 x 6" LL SD W/Y/osh»r SD W/Washer at Lap ! C--'�'"� /^..-•Jf 4 „kk , -� -o (Show'.) F f 5,ft haver. ,2T` # 3" O.C. max. 'C F \� \� Fastener #17A at 1'-0 O.C. . -T:: \ p.- f \ 5' sOL (Opposite) \ ..r Tae Sealer HW506 12-14 x 14" SD W/Washer P ,."'-• i i "• �'^",-- '\" at each pudin Roof Panel !! r (�� '^ Rake Trim I Standard F50 (shown) Large F3850 OovE oplt� I Pal Fomenter #14 "'•�� \ „� Angle 1 4" bead of Tube i :f abs Seain:zt ti ° x 2" ,' pF �- RAie Fastener #17A w iii Sealant to overlap I it S Fastener#14 [q I o. c. coca_ F (Far plaaS•PNni see &boils belle&) ` r: yy i� �� '12-14 x 14" SO W/Washer a 6 I Tape Scaler i�. 4"e %'e• se En, Cutter egg (Profl:a vis les. Northern F.,;1 ,,hewn) e Ij'-• ��-•'' .^i Field out ( 3 / PuNin 1 - - 2" ole. maz (For Placement g t lAl ,�_�-^^ �..�e\ Notch to allow , ^V ^'" a •�, �'' 'Mitered Eave Gutter Rake Trim to r see clot:Yc below) overlap lip of F45. (Shown) Gutter 4bend 1• Tube Sealant " $ y F46 (pnoeata) Field Cut Flush 11 tnd.G� u1 TOR (Showa) with: Face of Penal Ff 7R Sh.,n F3830L (Opposite) ar Trim (P ) Rake SI!ds Rake Trial F215 Roll Trim Rake Trim p ,.Y F471 (Opp°Hite) -Fastener #14 FIoIr Dn"e m`ne 4"d „ Panel Closure (seeOutside 600 Closure Out(See See GD06003 ` ( ) (Sao GD08003) Backside Vis'w of La _1 (profile varies, Standard F50 shown) S9¢ q y. ry fi i 9 i' m x l 2 e F383, fl hz8.i;lt {Shnxn) 2^ ac. mux. F.A31L to .1 (92) at Standard End CEP (14') at Large r (7) Fastener $14 (7) Fastener #i4 required at la r required at lap 9 P q p (7) Fastener #164 coq• .Tired at lap r 6 Fastener 14 {) � required at lap 1 mart. § I1%H LI Snec: t$ 3- G.rtter `I Fastener #4A Fastener OA caterer #4 Fastener l 1-14 x 6" U. SO W/Washer D W/Washer (4) Req'd At Loa Fastener#4 4-14 x 6" LLL SD W,M'oshnnr Faatener #4 14 s " LL S4 /Washer La O q p _ _ / 3= F szersr -4 d atener Xi W 4 T) F a. - ' @ t' i [ (f cp tae at la . i i (e g' G t f ra is?rs. a, lap 1 r»a�i•ad at < i • r ued at la_ ` re• uE sd ct In A p 7 P _ ") Apply lube Secicot to End Cap bottom and side la e, Install r Ca at a field d t rminrd distance In from the end of the p 14 x SD W/Washer 4-14 x 6" SD W Washer 4- 6" / !' at 1 -0 O.C. '" at 1'-0 O.C. Alternate SIIOin ( 9) ; (4) R tl A. Lop Q w, 1 i-4 (4) Reg tl Att Lop 4 I } i i t -+•=} `-...,f-� - iii Cottee Inspect after installing and steal any gaps with Tuba t i -aslant. Standard(Flxed) For roof runs greater than 100' For roof runs 100' or less 't- '( 1' a. % ✓ -f �.j ```^^^��-�tt r 1 . t wY ' "-' -+•-{ g@ 74" Standard ) Attcch Eave GLttor to Roof Panel locating end past face of i I t4"_ La:<r P %psi or Tim. (Sea Ca' -ter Placement) ... \\\lJJ r _ -.-d- Trim an !� S) Ala. r'gc of Eme Cult, and Rake d attach Rake § f 7J ( f" -Y-P '� s $ t t t 5:¢e jj Fee of rand Trim a shown. Apply Te Sealant along edeas to seal. ub l Lne: I p9 or 'rim 4 41 Sae Lave and Rake Construction Details Included with Erection ! Standard S once. ' Lunle Iva It -'. I Nc 4 m Large Curt r P -a n eni L 7c w- at`aehmant of Eave Cutter and Rake Trim to Raaf Standard Standard Large Northern Northern Large FAL P 8. ; ____.��.__' Anil.:. F30 1`38:A F234 F996 RLEVIEMED FOR CODE COMPLIANCE NOV 10 2016 INTERWEST CONSULTING GROUP U U m'' 0 O zk El 0 a O W Dan w w zaO1z m ti0>QZ Vl OOU _000Z •C y z�25 = 3c2a U Z3Nu m O Scale: NOT TO SCALE Draw, by JOE 7/15/16 Checked by. JAM 7/15/16 Project Engineer.• SG Jab Number. 15-B-39475-1 IShest Number. R16 of 21 I rears hereon is an employee the manufacturer for the terials described herein. Said I' or certification Is limited the products designed and nufactured by manufacturer y.The undersigned engineer Is the overall engineer of and for this project. . 7150732 ryyt R;rm 0wnspo-d Layout Gaeterip. ' n're-r ' c+° •,y Vary) Floe Loreto :xsenievp In tatID, k a Reiar to the v. a Ia :evn s 4 tto '.ecn a the '[orvsreouts. y p J r 2 Lo - no ai d e p uti o o pa el r a r e f F•aheOle i t 3 i Yield s iga S9 required; for and. he (e greater h0 ' C :. too a gra end of res cut P : g g e IMng :: Oatl at the aw. a!a Aft. c tang to length, ir..,a-k the swaged end c4 the cut than .cut into tin o of re ow r ,owns he b 4 Gof deo sprats i D, a e Lca ted at the oatpon h u rownsvafo below a atstr and at erld I.. .r. C4: dOWnpt'Sp. IaRgYI' ti. q!.. 10-6". iCa Gi�r:GD11 thN Q..rJ01 S" for d6b11 to.14 StPrp eCtitH'I.^.!d. age 's r5cc,< c. aD Attachment DP00011 PBR, RBR, AVID, PBA, died ashadow, & IMP Fully Sheeted Wall Date Rav Jun'15 G2 4J Facture VA--"`�--v rc Yoner 414 .t Oowr, J 14 x e"7()J:D }-14 x P SD :YJWesFer (1) et r7qr Guttnrccgn:wtn Downspcut Strop F797 - 31"x4' and 4'x5' Dawnspou±s (2) at r31, F903 caa FT829 (2) at FBI. =003 and F7 - I 1 U,,., D.nrI auc ( F - 6"x6" Oat posters, �:4 t } F7816 Downspout 23 - 8"x5 Downspc:;t F313 (14 -0' � i (1) Per S3ie at 1'757 MMS -)y t- Oownspa it Strop F737 (TYP) (2) Per Side it FBI, F'03 Sae OPOOt 7 thru D?04014 For (4"x5" Shown) aid F1829 F!Ty4, in:��4RgL.�tt4^,Jtm..�6i Downepo trap Fasteners Lnver Dr h#'olf -�"'e'-1._..__ �i Downspout Stoop ip'" F797 3}x4 and 4X5 Downspouts (1) at F791 q 7 FBI - 6"x6" Dawnspcut (2) at FBI, F903 and FS29 I o°� F1829 - B°x3' Downspout Feste,isr 474 Bead of HW54_ Tube Caulking ti 0 o F903 - grx9)" Downspout �a c F_ 4 Downspout `mss" Rp'l j (Y.-`. At S,Mka) (2) Per Side at 1`81 [0C3 IS♦P Wil Wane Attochmsni o end rl8'; �= Doerr onut Kick d Fant k a Reiar to the v. a Ia :evn s 4 tto '.ecn a the '[orvsreouts. y p J r 2 Lo - no ai d e p uti o o pa el r a r e f F•aheOle i t 3 i Yield s iga S9 required; for and. he (e greater h0 ' C :. too a gra end of res cut P : g g e IMng :: Oatl at the aw. a!a Aft. c tang to length, ir..,a-k the swaged end c4 the cut than .cut into tin o of re ow r ,owns he b 4 Gof deo sprats i D, a e Lca ted at the oatpon h u rownsvafo below a atstr and at erld I.. .r. C4: dOWnpt'Sp. IaRgYI' ti. q!.. 10-6". iCa Gi�r:GD11 thN Q..rJ01 S" for d6b11 to.14 StPrp eCtitH'I.^.!d. age 's r5cc,< c. aD Attachment DP00011 PBR, RBR, AVID, PBA, died ashadow, & IMP Fully Sheeted Wall Date Rav Jun'15 G2 4J Facture VA--"`�--v M�1' I{ v 14 x e"7()J:D }-14 x P SD :YJWesFer (1) et r7qr Downspcut Strop F797 - 31"x4' and 4'x5' Dawnspou±s (2) at r31, F903 caa FT829 (2) at FBI. =003 and F7 - Tf PlI29 8 xB' Downspout Frslane f"i4 -7 01 ( F - 6"x6" Oat posters, �:4 t } F7816 Downspout 23 - 8"x5 Downspc:;t 'u a i °h" Pre Iii SS � F903 - 9rx9E' Downspout (1) Per S3ie at 1'757 MMS -)y - Downspeut (2) Per Side it FBI, F'03 (4"x5" Shown) aid F1829 F!Ty4, in:��4RgL.�tt4^,Jtm..�6i Pop Rivet at 20° O.C. Fc t Wer lieA--Al 4 tt °D W Wether — Downspout Strap (i" y(1) of F'(�7 Y Down - 3§°x4" antl 4°x5" Downspouts (2) at 31, F903 :d Ft8 9 FBI - 6"x6" Downspout F1829 - B"xs' Downspout Footener p14 -J \ F9D3 - firxg:)" Downspout d N x;" Poo Rhea. SS . Dmvn out (1) Pa Skis a- F797 (2) Per Side at FBI, F903 Sk'i. h YSL+^-3 AtU:lnd (4"x5" Shown) end FS29 Faetenor #4A -.--I- I� ?I-."-_- - ---- Na{e: All trim 1.- to be Downspout Strap }-14 x P SD :YJWesFer (1) et r7qr 1+ ji+ / 1 Insilmlon Is a iced to vole. I F197 3d•x4" and 4"x5' Downspouts F8+ 6x8 Downspout (2) at FBI. =003 and F7 - tit PlI29 8 xB' Downspout Frslane f"i4 -7 01 am n. ®ec'11i 00 F903 9x7 xgr Downspout J"9 x J, ran Rivet °S b dare k or H N!cs P-!d'h Shaw en 4.'09021 ..enc tabs a :. Trim o vowr an f'h09024 Downspout (1) Per Side at 1`70 1v 12'1'2Rf'!y'3;S}law (4'x5" Shown) (7.) Per Side at FM, '903 Weli f'_gve; Ai!SshnS•si end I'Meg o c r x z Pop Rivet at 20° O.C. Fastener 01A -�"'e'-1._..__ �i Downspout Stoop II %e• ;D dusk ,hsr ip'" F797 3}x4 and 4X5 Downspouts (1) at F791 q 7 FBI - 6"x6" Dawnspcut (2) at FBI, F903 and FS29 I o°� F1829 - B°x3' Downspout Feste,isr 474 Bead of HW54_ Tube Caulking ti 0 o F903 - grx9)" Downspout b'4 x J* Pop Must SS c F_ lll���... Downspout (1) FC' Slie ci P17 (4'x5 Shown) (2) Per Side at 1`81 [0C3 IS♦P Wil Wane Attochmsni o end rl8'; of each member Jamb Trim F482 Jamb Than F482 PBR Wall Panel - Walk Door & Glass -Front Walk Door ,PWO! Trim Installation with Field Notch Panel at Head Trimyy yc Mg±c; Trim Installation can be done by Field Notch Panel as shown on PWO9022 & PW 23 Q& with Field Notch and Bend Tabs at Head Trim as shown on PW09024 & PWO9025. o is Door width + 6k" (+ 1'-6 for each SldeLite) o x — c 3 1i" Door Width + 3Q" (+ V-6 for each Sidel_RD) Ir o S See PWD! LL & PWJ3 x I o w 3 x w Door Width (+ l'-6 far each NoteAll trim is to be Field efore measure Door Width and Note. Installed BEFORE blanket Height bmaking field cuts and insulation Is applied to walls, ad)ust cut dimensions accordingly. PBR Wall Panel -Walk Door & Glass" Front Walk WD; Door P Field Notch Panel at Head Trim ___ec'1' B,gie; Trim Installotiun can be done by Field Notch Panel as ahowwn on PW09022 & PWO9023 Q,q with Field Notch and Bend Tabs at Head Trim Ds ehown inn PWO9024 & PW09O25. Door Wldth + 31" :+ l'-6 for each Sldelito) Door width 1,_6 far each SldeLlte) I r 1 a Head Trim F401 See P'WOSC2- i for Jamb Trim i Odd cut detail i I Jamb Trim F482 i or Optional F484 i i Fas Pop Rivet )1 at 0" x C. Pop Rivet at 20" O.C. 4f Fend Rib Door width + +_t'-6 for each Door W.dth V-6 for each Sid Field notch Panel at Head Trim Instclotion. • Panel os;tionn Is shown with � P - ---- Na{e: All trim 1.- to be I Head Trim F451 installed BEFORE blanket Door Wdth andd location. Field Insilmlon Is a iced to vole. I an sure before euttt!n P dpP 9 See x 3" F 9 ,'E Field Notch and Berl. Tabs =" Hl -ad Trirn mer" 4 e".. Dec'1.. 00 Jamb Trim Field Gut Details am n. ®ec'11i 00 PW090:50 i d O T rete potion a n L QEc with Vidal NOCI, and b dare k or H N!cs P-!d'h Shaw en 4.'09021 ..enc tabs a :. Trim o vowr an f'h09024 ;P & PWC9025' 1d 90231 J or FW0962 I ^� 113 O O W 4 '� 1�" Fastener #14A J" x r f o c r x z Pop Rivet at 20° O.C. DOE' Wfoth 3) (+ 1 - 6 fur won Sd Lhel - n 9 I „1 ao' W + e " (- i 6 to scab 5 tle I ::, ow Dao V.a_h + 6) l+ 1'-s each [- t "I D r Width - F (+ Iv -6 for each Sid.1-ter) 1}° -. _" ip'" g 03 Y m 3 c n fr x —_r...0 I o°� See PW09025 & PW0302y R ,F, F-��--�� ` n Hu .d tdrn F4 Bead of HW54_ Tube Caulking ti 0 o x s" c F_ from Header to Floor (see section) L E z o o of each member Jamb Trim F482 Jamb Than F482 I i r.., RON Notch and nand t} Tab tl or Optional F484 or Optlonal F484 i; e o 0 0 4 o h Walk Door Jamb Fastener #14A'0 x �' Pep g Pronle may ver ) Rivet SS at 1' 8" ro F ( Y Y. Double Fide Ripe 1 I pp I v-0000 fE ^�- \ PVC, e. 030 I \ or P W:4O32 Pastan,* 14A x ! C Poo Rivet at 2 O.C. i behind Jamb T Im. Attach w fh Fes ever a qqq I ¢i4 z`" p--- Pop Fvet. Son P 025 fur 1' Opening With Do not it or t' rtmav tor, k le Nate' All nm la to be I g Inatol'od Bic FORE blanket insulation is nPPIieA to walls C Bend 9 Tab 3 ,a N 3 i5 in tr �3" Walk GFro I 2" Glass -Front Door -- -\ (Not by B!d'g Mfg) Bianka4 Insulation / Sea ° \ tf: details. e 1a" down 90 eng ens t gtg� Panel position Is shown with Pone] Rb and Door oa V-0 modulo. Location of Rib may wry depending on Cut and remove remalndsr of front fold - oW PWO9031 1 �`- Chia of Hy -:4_ R.be Ca;r7kiny-///I I I I r Finish Floor Line _�� Rsid Ont the Door wAdth and location. Field and Remove �, - measure before cutting Panel and Trim. Door Width (+ l'-6 far each NoteAll trim is to be Field efore measure Door Width and Note. Installed BEFORE blanket Height bmaking field cuts and insulation Is applied to walls, ad)ust cut dimensions accordingly. PBR Wall Panel -Walk Door & Glass" Front Walk WD; Door P Field Notch Panel at Head Trim ___ec'1' B,gie; Trim Installotiun can be done by Field Notch Panel as ahowwn on PW09022 & PWO9023 Q,q with Field Notch and Bend Tabs at Head Trim Ds ehown inn PWO9024 & PW09O25. Door Wldth + 31" :+ l'-6 for each Sldelito) Door width 1,_6 far each SldeLlte) I r 1 a Head Trim F401 See P'WOSC2- i for Jamb Trim i Odd cut detail i I Jamb Trim F482 i or Optional F484 i i Fas Pop Rivet )1 at 0" x C. Pop Rivet at 20" O.C. 4f Fend Rib Door width + +_t'-6 for each Door W.dth V-6 for each Sid Field notch Panel at Head Trim Instclotion. "OM Wall mI Walka r t: (?ass 4 resat Walk Door • Panel os;tionn Is shown with � P - ---- Na{e: All trim 1.- to be ) RPo and Doerr, on /'-1 module. tion of Rib many vary depending on [th. installed BEFORE blanket Door Wdth andd location. Field Insilmlon Is a iced to vole. I an sure before euttt!n P dpP 9 "OM Wall mI Walka r t: (?ass 4 resat Walk Door r4'd03024 ; P ?R a",°'a!I Pane? - Walk Docr & G'ass-Front 4Va41c Door PWOS025 PBR Wal! Panel -Walk Door & Glass -Front Walk Door PWOG027 PBR Wall Panel -Knock Down Walk Door `PY109031 Tf1m Instealxxtion wqh Field PFT h and Band Tats at Head Trim a aa. ���'1A 01t x 3" F 9 ,'E Field Notch and Berl. Tabs =" Hl -ad Trirn mer" 4 e".. Dec'1.. 00 Jamb Trim Field Gut Details am n. ®ec'11i 00 x, Jamb Trim Installation Mar'15 02 d O T rete potion a n L QEc with Vidal NOCI, and b dare k or H N!cs P-!d'h Shaw en 4.'09021 ..enc tabs a :. Trim o vowr an f'h09024 ;P & PWC9025' 1d 90231 J ,� rrr--- Int+. witT "ih Installation Nott cao be down by ofplaid Notch Panel as shown on PW09022 & PY1090?3 L P win Fleid Notch a d F'antl Tcbs a Head Tr rn as shown on PW09024 & PW09025. far SldeLite) I ^� 113 O O W 4 '� 1�" 15 `o c r x z 1 DOE' Wfoth 3) (+ 1 - 6 fur won Sd Lhel - n 9 I „1 ao' W + e " (- i 6 to scab 5 tle I ::, 1 " i Dao V.a_h + 6) l+ 1'-s each [- t "I D r Width - F (+ Iv -6 for each Sid.1-ter) 1}° -. _" ip'" g 11§" HW54_ Urethane Lbs .,_slant 9 Bead Header to Floor 3 c n fr x —_r...0 I _""�' __... See PW09025 & PW0302y R ,F, F-��--�� ` n Hu .d tdrn F4 Qptienel Jpmb Trim F484 Tia View b 0 o ti 0 o Jamb Tr' F482 Inn Mew 4�' RAI Sheeting Angie From base to 7'-6* girt att ch withch at girt and (2)Fastener 12A 12 144 x 1se " ( ) ! Pancake SO W/O Washer c F_ L E z 3e" k" of each member ,+.:-�� -�x F,ar Tim F481 Sa i r.., RON Notch and nand t} Tab tl Front \iE1 EGO err End Cut Detail i; e o 0 0 4 o Field Cut and Remove Walk Door Jamb Fastener #14A'0 x �' Pep g Pronle may ver ) Rivet SS at 1' 8" ro F ( Y Y. Double Fide Ripe 1 I pp I v-0000 fE ^�- \ PVC, e. 030 I \ or P W:4O32 Pastan,* 14A x ! C Poo Rivet at 2 O.C. i behind Jamb T Im. Attach w fh Fes ever a qqq I ¢i4 z`" p--- Pop Fvet. Son P 025 fur 1' Opening With Do not it or t' rtmav tor, k le Nate' All nm la to be I g Inatol'od Bic FORE blanket insulation is nPPIieA to walls C Bend 9 Tab 3 ,a N 3 i5 in tr �3" Walk GFro I 2" Glass -Front Door -- -\ (Not by B!d'g Mfg) Bianka4 Insulation / c ° \ tf: details. e 1a" down 90 eng ens t gtg� Panel position Is shown with Pone] Rb and Door oa V-0 modulo. Location of Rib may wry depending on Cut and remove remalndsr of front fold - rnl 1Q - 11 1 �`- Chia of Hy -:4_ R.be Ca;r7kiny-///I I I I _�� Rsid Ont the Door wAdth and location. Field and Remove �, - measure before cutting Panel and Trim. )))��r---...///,,, Field Cut Wall Panel ,Y_ - I ( from H;:adar to floor era section) I ( } 1 I i _^---,�_--_ jN1 C,Vi GaiyiE ¢Panel Rib ('Pawed f-om top f t d Trus) r $Ido View at Head_Idm, o o PBR Wall Panel [ i o E m .., I Jamb Frim F482 amts Trim F482 , ori`,td: no: F454 c CIAron F484 I Door Width + �Ita`" ( + i' fi fo each dN to t �n Door Wath + 3 N n _x o 3 Ns3s; Tarrninate Blanket lis Tr ion ' at capillary lip of Jamb Trim / 1 I l I { ay I .:._.)._ Door Vad h (+ i'-6 for each gdeLite) (. 7 6 for el'in SHaLl o) 1> !� I r! r } o0 3 Door Width Field Flattsn Trim leg when re(luired -r Doar Width 33"—_ JJ f ! 1 f t ng .e cr i rru.,..3i Field Notch and Bend 11 rob -+ S y�' v behin f Jamb Trim. Attoa+. with II -_' �--""'t`�'- y 5 rlY t r� .i Fastener y rsg" Pap R!w_} o }t' !1 { I I o I ° 'h ! _ + Jamb Trlm F482 (shown) or Optional Jamb Trim F484 i I I E (E14 x IGY_ L's,_._.� ' 4 't _ Head Trim F48i1 / 7 h Fintrh Floor Line IT < d N + to s S. t 1 _ �,� ea PKJo027 fortar:;±-7 8 flaw cut d alt i li II I t i l n 4 ti 011t F oc.: ae.3 I �/ i : I ! 6LdelrLew at 5111 Trim Trlrc. F4'-4 Prn tle a Ir ash Trs, F482 tjt k, or Op*1_nm F484 ! A , I I� I I III tt lamb Trim F482 and ySetC;_ Pnnel Post4bnn Is shrwn with t- S USCG. JI t : and � sin 2r ...; t �- i•- I z No•e. 9 Fetd measure poor Height before mining Reld cuts and adjxst cut dimensions Optional Jamb Trim F484 Front view _ Patel RID and Doerr on 1'--0 module. Nate- All trim is to be Location of Rib mapy vary depending on I t l' a: old x'. -. a i to h in an J ,ovula. .'qt t L rr .: r: f s d ru m Fc. emer ;14A v x g -� I _,. ! _ Field cut Pare', Pop fco-ai e' 20" C:'. {` 1 accordingly so that Jamb Trim fps to Head Right Jamb Trim as shown installed BEFORE blanket the Door width andd location. Field In.ulat!on is opened to walls. measure before cettt!n Perot and Trim 9 ins s n: 6 o"01", o +t_+, t .1., a+s, ar.4 c. a n ;q , f - Trim & at I'" below Finish Floor Line. Left Jamb Trlm opposite hand UT°'m CCOU Q!TY 1► L'tNO �1`JBSI�JR! AP Po REVIEWED EOR CODE COMPLIA NOV 10 2010 INTERWEST m O r 's OZm CD' � UNU� O Scale: NOT TO SCALE Drown by. JOE 7/15/16 Checked br. JAM 7/15/16 n Job Number: 15-8-39475-1 I Sheet Number. R1_ 7 of 21 The engineer whose seal appears herson is an employee for the manufacturer for the materials described herein. Said seal or certification is limited to the products designed and manufactured by manufacturer enly.The undersigned engineer is not the overall engineer of record for this project. 4 1 , C G E � u O O W a -is ZN oZ<m grrtin oc Z -x WU RpRtt g fans i3.iMU JuP 0 E c F_ E z ON [ =D6r m v-0000 " 9000z C 90002 " Z U< r 's OZm CD' � UNU� O Scale: NOT TO SCALE Drown by. JOE 7/15/16 Checked br. JAM 7/15/16 n Job Number: 15-8-39475-1 I Sheet Number. R1_ 7 of 21 The engineer whose seal appears herson is an employee for the manufacturer for the materials described herein. Said seal or certification is limited to the products designed and manufactured by manufacturer enly.The undersigned engineer is not the overall engineer of record for this project. 4 1 , Per%irtf !l Panel k'nocok Soy . Mlk Door PStd Rcof Panel GPR00008 PBR Roof h1PR00001I PBR Panel MPR00008 ae(td Urnj`, ,:; T me e15�` D?I Per aster Trim. Faseefl�r and Sealant Reference Oct '141x00 Perimeter Trim Reference - Standard Trim Mar'14 n04 Perimeter Tr'ss nReference - Tr hi Fastener and vsealant Jen'10 x07 v Wkhe Law PBR /- GiFt h _SSdS11-da- RAN -j 14`x11 AJT.P"I -� ! { GY£R X'AN_ YALL Y I t YG ) � CCNONUCtis EAVE HIP PUSHING GUTTER GUTTER NAP GUTTER CAP EXPANSION CCVR GJTTER f 1 _� �-. )I ° f F390 FM f293 F264 F]i F46 2' LAP F47 FW/F653 F&93 _ C Saw Trlm Eave Trim V" C!oaare Vxtgd Ridge Mabta! Clawre Le lHutlNaIP4 dge FC }°W:C 1 h' � Sr" ltib wlenl Fantnnet Fmlerver N Goes 1/4-14 e I 92' Tub" eedanl tY TWe Smlmt —(12) FMenw /I4 2) Fasi /41/MN x 5p (2) /-h � iK LL so wndsoner (13) Poetmx /H (12) Faelanar p4 Ttlm CJw LL So W/VAWa FGB 2° 4iP NY4aAD tHWWA1 Hw"Li96 Y 1,^._ } t. Li I L") Fut f! 1 a 1 H.:. • -14 x j sD W/ Washer .{-t4 x j° LL sD P o- 0.a mm Gbr mm CJw R+or edea ((S k 9 y / xF.. Y { 1. :J3 _ i. N t 12` DO W/ Fkoe" Rggf war i) Fastenerµ 1/4-19 x ;'�1 Answer }4A 1/e -IA x b° 6 T=A+ Sas ant (3) Ftel-er f3 (3) 1 F-xarw /3 re0'-0' Ie, p at q`, -'x s Wj e,,h P Lee 24 T Sa .. P+r F,,t Tflm Ctlar 1 el e" O.0 & (6) LL yyTW an WM'atlw 1'-0• of (12) F.0 -ow j14 12-14 x t Ile LL So 12-1,1 1 I"r LL SB F[$' T,^m P-LWMdSeWcnl' hon lsAw w i iywohe t 5: o OCA Tian Ccfv (2j Faherxonsets, f{4 -td x b' (2) Fm! wW yV 1/Ar.14 x j` _ - RealytGYw RR. Cdc Fa 9 9i 'ui to '-� 1-_,..'.-1,—_�. f T'ed CMw than W re, u. sas Wgw/'dandow' r'k mer I -----..-_.._.._.. V Toes 1.11 W F/ Fuca 'r #14A �'3 x �' Pop ,,��jj�� ��� Zeoetft ea " RAKE PANE LAP COP.NER BOX RAKE CAP Peak Sox L F50 Y LAP F430 F51 F916 _-1- - _ ale Fartan<r $9 14-14x&' 21' TUM Could. i]' Nbe CauW4p 91- Tubn Cealml (t2) F+elwr /4 Expanalon RItl9e-_ RI2gB Claeury RM E. TrIT Ind'Ide Clow.. Outside aoauro F u ED W me (7) Footwear 914 (e) Fnmalnr /14 ('Ley restore 014 1/4-14 x S { ---- y - 1'— D.C. (4) Fastener y4 (3) Fartemr N Mm Wo,r LL Se s/wz°, F675 F6]4 F2953 - HN455 N4YASG 999 1 II c Fastsner 91A 9/419x]• 1/9-14 x j' Y/4-14 x j' (3) Noweener fM — -- ao Is Nw LL m W/WaM LL 90 W/W+Mw 1/4-19x(' Fue4nv 941 4-14x)' 3D° TUM GVWn^° I 0' Tnhe awlmt and TrKn FAM Volk Cuor Header _ �.-.-v- I_ 1'-D- oc Ten Coker ram caw. Tnm cmw sD w/W:renor how Cdar 1 2 vre at/s' ac 1{9-14x; 914 5 W O.C./cul E � � ._J LL Cl W/wai[w (12) Tow= {T (2) Ile W 2" Lap 'ProfU« may vc,y, I rte) Fastener st ri/mta✓✓ti 4 x C u rmm roll an L, 1°-woe wec , •- ---•� pea on Trite Cdw Trion CGw B o "I ea" ruse sea am x - ! - Mp Hlgh c R°rf ape Skb Rake k1 uLa 8r ' s°tm m Leet f tt . ^:h emw 10' Car, Lea Los 10' C seam w E swear a eC'y°i n L Ft f L & C law IO�Cga Low 10" C. Low Eove '-,m HiGH51DE HIGHSIDE LAP OU1510E CORNER INSIDE CORNER �1 P.S i2 r^ SC 29.6 2500 r2JIN _ 1`2G62.F2D63,F29R4 F2955 754 r LAP Right as Shown Fold Weak 12 TJr. Il r e alwl 12 1 s S dent I 12' Nbe SBuieel ruM Sea4nl Raka Side Trim Ind,. Co, Parapet High SICe Par t Rake hkn J F'o. 4 =) F se' IN4 Y F saner $14 ]) xaetwls ji4 I2) Faetenm 4 tiv Fex:en N 1/4-14 x j• 10' Tb Sealant 19' Tuba aeOlmt 1B' Tube sestet 9q P 9 apes /, () i ( fl LL RD W/WeNn (6) Faatwxa /14 (e) Famw 04 (6) Renter, /14 F215 i5? F}9S F952 Fop RFnt Far Ley ,1, K li Per Rl nt px Lep j' x ta• eN, Rvot er I,p_I l{' x f Pap Red pm Lap d° x a' Pap RMid Per Lep 1'-0. O.C. (2) Fastener N (3) Faetenw 1'4 (3) feeler 99 dmw /1]5 15-19 x ij" Pnelmvr /IPA t2-44 a it'IFap!gntr 911,412-14 s 1) Fae'.+nee /!]A 1G -t4 x ti Fmb,er j14 38' 0.0 WIa FoRAm, /4A t/Ile x %' 1/9-14 x r 1/4-H x it 1/4-14 x r' 554agv/ Wrehx 24- C.C. Tea, e^ :'/ we", itrO.C. `L Wi Wa'ehw 24. so Taal .W W/ Washer 24°o.C. aware Fastener 4A Faebna IDA 1/4-14 x j' 121' TQw wv+tk H' Tub" Se+lmt 2Y 1T,G.o evatoni 91 W x W C. TH.,n LL W/Y!p h> LL 9 W/Wmha LL 50 W/N'vue W W/ kedwe (12) Fastener 93 (2) Fastener /14 4 (3) Fastmner 1 3 6 12° O.C. 9rAtan F . t Na 11° ^ c 3 & 11 4 C. Ua;ter xt+n^r 9fA too• 0 a i' van Rivet iz• e.c. w/ f -o o.c. IHm cav Iwo calor o n Cdar u1m cater _ 94 /" 4 x 555( Tram Cow' Tim Cnl T1n C ear Tnm Co.w Claw TT,Itn Ce., Tn0 12-14 " CarrW/IYv 1 re LL (ALL WWe pt Lx WCa N THnn C (e) FaABnw 0adwww�LJ Floor Lino W -x 1' -COC TM1n CNw .Lvs _-! Fen,Y eller 1 C, Ruse Gutter Gutter Gutter Gutter mnePy-nq east crexl-i-J-Ar sera cen,ft seen aasrorta°aC -an 1.1, Ce, i ` Bigh E;" Csa H:9h GLI" Cna b l,h 10` Ce, High 10" Cas Flodsg Eovs Tdm OUTSIDE coRNER INSIDE CORNER OOTSDE CORNER INSIDE CORNER F296 F h R F^9 ] F2 fk9 F2969 1`297O.F2971,1`2972 F2962 Right as Shown all Work Reid Weak Red" 5 A{t Trim !9 La ha te. TW Sealant 1 T M1 eased 12- TUbo aaolan: 1Y Tube iw.kal4 9' Tufa Sealant 21- Tubs Sexism 2T Two. Sedane 26- Tube Second 2R• TWro awlont N (1j Fou< m 914 7) feesenor p114 (7i raster /14 (n Fastener i14 Frowns, {NA ;-14 x a' (10J Fastener /14 (13) iaetanw p4 (14) Fmtry F14 I14) Fcxlenw 9r6 �4=a1SOd Tj'FCI:RE blas k0t rc.x- pop lard Ter Lee 9" x ij P River pe' Loopp }" x it PoP fo t P Lap 9 x �j° Pan RIM pea Lqp W W/ Wavha 1Y C.C. (S) Know [e N (3) Fastener M Trion Cdx hien Cow vlsr'atlon i3 P9 pi ed t J w ale, haiev 07A 12-14 x It Fast ®1JA 1 11 X Ij- 6aetEoar p7A i2 14 x i F tear WA 12 14 x it (2) FBBtanr /14 i' I}° Y/4-14 A r 1/4-14 x s bpbpbp :DX{ Wowha ae C.C. Tw 5 W/ W+-41 24 e..0 0 W/ Aa:her 24 CC Tor, s0 W/ Owner 24'0G Pop RI re, 2 LW LL a9 W/washer LL aD W/Weehv & Ir Ga Settee I FeAwwr 9l. 11 Go & 12. Go. Sour, razima 04 12' OC Trlm C:Ae, N. Color bbn -or *J E Refer to bill a mater Tats r Less'' oa rv:ln,e'^1e'?ts Fas.wners (00 4�--vv "; r'u, ,'6 Topa Sealant and iiab�Seelant P'y0000005 assts rev PBR, PBU AVP, PBA VistaShadow ' ' G0000061, G000009 �+ Aug'15 061 3a& Nov I5 10 a_ '-p^�----- u L4 Oct '75 03 Panel Fasteners Various Fasteners tg?4 I FASTFNTrc+?2° ---------- Wall Fasteners Roof Fasteners OP±Treat Roof or Wall Fasteners Fosterer #17 Fastener #38 SWInless Steel Cap Tri -BEAD TAPE SEALER n AT TAPE SEALER TAPE SEALER - SWAGED Long Life (Optional at Wali) li ^B@ j HW504 Fl 507 HW515 M.iPTberScrew 12-14 z 1" 5/16" Hex Washer Head 1/4"-14 x 7/e" Lap TEK 5/1.6"Hex Washer Head Msber Screw m Mg•nhecrew- S N! € ,1 9!`.. 1 i5" X I" X 25'-0" X E" X J' X 2.}" X 6" Fastener #17A 12-14 z 1}" Fastener #3 92-14 x 14" Fastener #3SSBX 12-14 x lf" l w/ Washer F- i -T Terser .t4ub..h DY8-r ^rn*r.ot Washer TRIPLE BEAG TAPE SFnLERI HN -02. 1 F,A.'T TAPE SEALER HWSDB 6 qb Hex Washer Head w/washer " Hex Washer Head w/washer 1 Hex Washer Heed w/washer {° 33�:.' T9rJ"diTTfl4 BattenLok HIS - '1. it Fastener #12R l r�_ 11S X. 2*" X 20'-0" X i" X 45'-0" SuperLo Mg.'rylSr��L. l 12-14 x i" DP3 Pancake Head M mbar Frew M9l➢b@f_$FCC.W. AC Ir 14 ' '•�- - A "+1 A =1-+- '- T FR 7 'may- .2_8 Optlold Optional Optional Fastener #17B Fastener #3A Fastener #3ASSBX l A HRETH. rtE nJiBE SEA.A!_ANT TAPE SElLM MINOR RIB HON -SKINNING BUTYL TUBE (VAPOR BFALA R) 12-14 x 1}' 12-14 x 1Q" 12 14 x 1j" .� •d' -_fit t� Hex Washer Head w/Washer. A" Hex Washer Head ./washer Flex Washer Head w/wosher r oil .pl o„�L• r Fastener #55 Fastener #70 Fastener kkg 7/E 3/16” � t/6 x /A I 3/96' x 9JtA' � 1 � ~` I 12-24 x 1 9/4' DP5 Hex Head 12-24 x 1 1/2" OPS Washer Head 1#142 1/4"-14 z 1 1/2' 1/ S/16" Hex Washer Head F -. heat ; sap R / f Glared End Rivet HIWIgAp (t;`h'ts) 5/18" Washer 5/16' Hex Member Screw Memo,, Screw i it S,afness Sired Siapza a .. H" 541 (Gray) try" " X Y 4" IMP7100 (WHITE) Member Screw f # W ( HSY542 FBronze) tn+{e: 25'-0' per Tubs a1 1/4° Baod I 1 " X GA. Nets: 92'-6" per Tube at 3/5° Bead — _ FLEXIBLE MEMBRANE (EPDM) Optional FCst•TCr #28 - 92-74 z 2" Optional r Fastens #55 72 x 2" Opt'Onai Fastener #272SSBX r" 12-24x.. DP5 _ r jpe s g � WIDE 24 STRAPPING &' Hex Washer Head w/washer (�" Hex Washer Head w/washer {�" Flax Washer Head wJwasher i� Fastener #76 Fastener #61 :0 ..an3.,'....,r....._.." ini.T•. rr..:�Yl e.. y. _ 1 .I 12-14 tt 2" 12-14 tt 1 9/4' Fastener #iB 1/4-14 x 1 1/4" e#`i'��,, *: ��`..' i�� �. b 3 5�_ o" Hex 'Masher Head /1„.. 5/16" Hex Washer Head 5/16” Hex Washer Head Smah SCreW Stitch Screw LT. P Member Strow 5/e _T,P rsmbar rev an' ` {. y Lire) #i`+ x i" Rub:»r Crammet s✓ ` S=`1 1` siacll $Creta [i' 1 516'Pea -er He'd Ile -14 A 1 Jn I '^%1 1 -JCsn Head ! 1(4" Hex Hftad w/ ia(aa :E'r � z'� /I ! w/ 1 1/8 ,20 W.s.".a wj 1 1/8 0.0. Ma t.Fr GEi<Sln!F 7 V/.CE = HW5227 d...`_�e,'l ^v. Fastener #4A Fosterer #4 Fastener #45SBX +V CEKSTRIP 4' WIDE HW5223 .v Tp•l <4_.... S enc f,NE F. ,g 4.,_ e <,-+,- ( r? gc DEKSTRIP 12" WIDE IM6229 ('g" Heir Wash r Hard HxWasher" Head {k" Hss Washerr Head Fastens #78 of N01E: Refer to Fastener #46 5 t j a Ta c R ! _ Gray O " O. c PRYS 2 0... MAX.44XPF. IMF?.:R TOE SES aNr BOTH S DFS F' 470 -' 25'-0" Roll Galvah:m6 Plus Only FII - 100,-C" a HW520 - 96" x 50'-0" Roll a )gWB21 - 24" z 50'-0" Roll w/washer i' w/washer z w/washer 1 x 11' Pancake 9D OPS Pancake I W/0 Washer materidle for spedfc Jcb specific requirements 1/4-14 K 5/8" Type B ion 9 ' Ir211'A� `' � � #•'i 7, .. .�„�� UBr -LATA\ EACH EN n 1 Yell Iva Lame Plies Ont '. Ha J 5/16* Har Washer Head W Washs / T-RIAINATION STRIP HW5305 EACHFL5nq - 5G''-0' Roll a tl ESD (1' Wide X 4'-0" tong Alum.I 1 r � Iv na Pius m hWh C' Woa asos NOTE: NOTE: Refer 4o bill of - ( LT.P. oto H c eR I Ta '-,Rch e,, (.ono Llfe) i #}4 x 1 1/5" QD. Refer to bill of materials materals for specific job requirements j- -t4 e 1/d I }/n 1r r /,, Bonded Washer for specific job requirements pEV,1£" He. . , ice F. •sd I 5jt , h�:..., z- Heed ( � ..�._.....�.—._._ w, i ', Lea c1u. e{;•:;nr W%11/ f)O. `Y -her _ PF BUTTE CO— LINTY BIJI�-LMNG DIVIa10- PIP` �l a. s' a Id 4J -11 EVVEU FOR CODE COMPLIANCE NOV 10 2016 INTERWEST CONSULTING GPO I ID a U m to O .e C W D C Il o tl SF o `Ibg c o S o0U � J O 0 3N w now N O O R ozaO3 ® ❑ �� 2QiWU /p T P • U W_ O 'm NSU ® $ OQb G FR ti oc Is ¢ Fh z" L.1 Ri��a1 Z+ ITV z fn ❑ ❑ Fan ZQmZ E MQZ to OUO to o OVOZ •� NZ^UQ 3 u 5"Ono 0 Scale: NOT TO SCALE Drawn by, JOE 7/15/16 Checked bug JAM 7/15/16 Project Engineer. SG Job Number: 15-B-39475-1 Sheet Number: RIB of 21 The engineer whose seal appears hereon is an employee for the manufacturer for the materials described herein. Said seal or certification is limited to the products designed and manufactured by manufacturer. only.The undersigned engineer is 333 .not the overall engineer of record for this project. Ronald W. Bennett, P.E. California P.E. C050732 € Fhlsh U:. tS at Mated CC: i:er ur3lUnlrf Side-wall Cyist By Pa_=es i'cha,nn - -- — gr"G Baits'" rS054 j Sheeting Citp Endwall C1.22 or PC30 -t Shoe`.l.^.g CRs (1) r siio rr #12A. 12--14 x Y' P.H. DP3 aft each and I I �j� ntwa!!f cit ill I i C 292 e & PC76- Clip s: siting chip F —� r iz-14 of each end Shealing Clip Il ,EWALL PC7d_ Clip Ci -4 (v — - _ Endwall Column attart mer: — — located Fotween Purlins at Slope Notes;. f.l ;Tee A -00091b ( ACEOB2gfor Jemb/Supl:od Coh}nst alladmw-nt when crated ai s _ ePor n span (w ad!acentPurhn space) as Endwall Column 2)F +g Chmnel ma, sea,) rdNee Puffin npioeswfier. required. 3.) VNand Edge Strip Punns, v.,en requ r'll, do not at+ach to Bridge Channel. 4.) PUMAS and Pudin Scut a#erds past Bridge Channel flange when "Ootiminl' Ova lhlra or Facade 5 requires! at endwali. dl_ C'airn7`1 Pullin Stot (When required.) (Typical of Purlins -^i and Punn Stmt) "'YJ ---Bridge Charnsl Cold Formerl (Shown) HotRoied -BG (Simi nae II (.c'unn or Ca ul n -xlsn_Inr fBr to p+..hi!I Lof Cr rection 7latu.) 102 PBR Wall Panel - Three Sided Framed Opening PWO' 01° Trim Installation with Field Notch Panel at Head Trim Sep'1+ Ft- Trim Installation con be done by Field Notch Panel as shown on PWO7022 & PW07023 OR with Field Notch and Bend Tabs at Head Trim as shown on PW07024 & PW07025. Opening Width + 6" (+2" Lap when req'd) 3" Opening Width — " See PW07023 & PW'07027 PER Well Panel - Threc Sided Famed Opening Trim Installation Fiend No` i1 Bend Tabs Head Tram ux en PW07024€ PBR Alai! Panel - Three Sided Framed Opening PWO701 '14 1 a 03 wain and at jS1 l 1 Field Notch and Pond Taps at Head Trim Se or `o — 9 n — --- jN.at.., Trim Installation can be done h Mid Notch Pane! as arrive) an PW07022 & PY'0i023 gp -1 L t Field Notch Hand Tab He.:d slim e,, at " H Cie. at For,, , R --- r Tim Inntailaion can to dace b .Fleid Noich Panel as shown on PWO7022 & PW117023 with oral a4 as sho wn on PW070"4 & d PNC70 5. Opening Width 3" wt H Fizid Notch and Bend Tabs at Head Trim as shown on PW07024 __—_ & PW0707.5. O J bbl Open'z Width + 6l' (a ! „ d) the Opening Width cnnd location. Field Opening Y'!d n + 8" (+2" Lap when retid) at r t Pa ad sg P Field out red -. " d _� •- aq P R .Y,ryv3 `Iti rI .n Wiri}h a :5• .vs{ 9nc. Cut '-Head Trim F48f Rem*Field ondsr and & PW070<7 �yyyGGGppp I P..(7 -,Y0 pqp l Fi 1 or `o Faataner x 4A B F 'c P n'i.et 9 n — e,, at " H Cie. at For,, , R s j Fa txrm I Opening Width 3" 7 12-24 x 11 k Pn c .e bG DP5 Location of Rib ni vary depending on O J , ' -0 S~ f i ot f B O.G. the Opening Width cnnd location. Field Jry at r t Pa ad sg measure before cuttting Panel and Trim. R "Bead of F 4 ,:e Coulkkig r i 4 *am Hip U t. tile, (f*K 8 l:ll^.) ... PWO7028 '.Tai lij i t iamb Tri, F4"n J,,nML Tim F482 OR al -<nz Aiturnate F484 ar F?tamsle F464 )I Jes F, a l I i :{?7029 FRtiY Gloss Urs, s. Cut FW1,37025 Rem*Field ondsr and & PW070<7 Remove Head Trim F481�� See s. rl °Opening Width 13" r I Head Tim F481 I I l :ti f +l(Qfn- Field measure Opening Width and cut Head Trim to required ,jleenngtth. t -Field Notch and Bend Eant lx_w End mew 1+" 'ab behind Jamb "' --2" Lap with (2) Fasteners #14 See End Cut Dollop z Pop " P,ivet and HW54- FletAttach w74h Fletcher #14 n' r 4° Caulk',rvg Foo R et Sao i) rpe .:a lidbh _ P W07025 for dstaAs. �� D na °o fir' NnSa_ All trim isbo can fir back ley nsaBEFORE blanket Insulation is applied to walls 8J ice' Berd 1d tab SSS vd i down cogreee N2:flt Panel position is shown withnta k ! J I 'el Rib and Opening on l'-0 module. Location of Rib may vary depending on Field Cut -----i t`e Opening Width and location. Field Y. and Remove �. _ -� mac"ur" before cutting Panel and Trim. I .._ rnA Cu GAyi! " 2 Lar wi ` 2 (Viewed Prom tap of Head Trim) Fart.nan #144 p x iT Pop Rivet Jn2 otTNm wn n DParinq Width Opening Width _ _ req I ed Fluid note?) " ( ss required. In Field Notch and Bond i Tab behind Jamb Trim. At Yash th Fastener /f14 ," x Fop Z +ot Far "Optinlict, Nota ,.jam i y t _ft P Er7c70FS +2B / e Hear.' Trlm r 3 ol See PW070 7 i r J r a -/ Trimfield "t detclt 1 x3 )+I in .iamb Trim F4$2 at AlCemais x484 ( It Fostere. p11A A" x a" Pap RN., of r g V-8 O.C. at. Cold F.hno i It it o OR k - -- Fastener - i z41 - v it i € nl t t i e b. p iz F'wc measure Oner rg rfd:h 92-24 x 1 Pancake S0 D�5 W/0 W;;aher 1111 ("` i Pf r (F n_ rket s i t sigh. before 'mFk4 1 1 a alta �" le m 1 t r! wt! ! a t dMe. cut dimer ane v ,xdtagty. a4 1'-8 O.C. __ Field cut Panel _ __ ___ ...._._ _ at liot Relied PBR Wal`: Panel Three Sided Framed Openiing - TWO; Field Notch Panel at Head Trim Se,e Ng't Trim Installation can be done by Field Notch Panel as showsn on MY07022 & PW07023 rd4 with Field Notch and Bend Tab. at Head Trim as shown orn PW07024 & PW07025. Ooenk.0 Width + 6" (+2" Lao when reddl Notes All than is to be N tee F!cld measure Opening Kidth installed BEFORE blanket and Height before making Fleid cuts Insulation is applied to walls. and adjlast cul dimensions accordingly. PBR Wall Panel - Three Sided Framed Opening Jamb Trim Field Cut Details ��E 1§" -E I L 14 3, 1" Altemate Jamb Trim F484 Jnmb TdmmFF482482Top Vivo Top 'Ae. Field Cut and Remove $ids Vew at Hegd Trim � I + rl o I o Head Trim F481�� See 12-24 x 11x" ED Pancake DP5 N `o PWO7030 at Ho. Rolled — LOGT Panel Positionn is shown with ti Nota Opening Width 3" NQfn�.A!I trim is to be Location of Rib ni vary depending on O J For *Optional" the Opening Width cnnd location. Field Jry Fastener #14A b' x Ir Pop Rivet at measure before cuttting Panel and Trim. Channel Closure Trim ®❑ V-8 O.C. at Cold Form ... PWO7028 0 OR al -<nz Mono Fastener #16 M 12-24 x 1j" SD Pancake DP5 W/O Washer E o at V-8 O.C. at Hot Rolled Z V E Qui 4 gU w re 00 J r Bead of HW54- Tube Caulking L 2" Lap with (2) F¢n w Z§01 from Header to Floor (see section) o Fasteners #14 � 00 m Z0�p n Cp0 be Ir x 47 Pop Rivet Head Trim F481 a(PNUm � Jamb Trim F482 Jamb Trim F482 Drown by JOE 7/15/16 Typ at Head & Project Engineer So Job Number: 15-B-39475-1 Sheet Number.' R19 of 21 or Altemate F484 or Alternate F484 Jamb Trim when Sae PWO7027 required. Field notch far Jamb Trim as required. field out de-tvii see' PW07029 Jamb Trim F482 or Alternate F484 Finish Floor Line " it Notes All than is to be N tee F!cld measure Opening Kidth installed BEFORE blanket and Height before making Fleid cuts Insulation is applied to walls. and adjlast cul dimensions accordingly. PBR Wall Panel - Three Sided Framed Opening Jamb Trim Field Cut Details ��E 1§" -E I L 14 3, 1" Altemate Jamb Trim F484 Jnmb TdmmFF482482Top Vivo Top 'Ae. Field Cut and Remove $ids Vew at Hegd Trim � I + rl o I o Fastener #16 12-24 x 11x" ED Pancake DP5 N `o at Ho. Rolled Sids_Ylfl�gt_ iS 11 Trlm NaSe� Field measure Opening Height before making field cuts and adjust cut dimensions accordingly. I II Cut and remove remainder of front fold (2) Fasteners #14 x 4" Pop Rivet at lap 2" Lap when required. Field cut and notch es required. Jamb Trim E482 and Alternate Jamb Trim F484 Front Yew Right Jamb Trim as shown Left Jamb Trim opposite hand Finish Floor Line Lop with (2) Fasstoners #Y4 FJ'-d-Y"12Y x 4' Pop Rivet send 1iW54- raking Ana Wtl,� 3"' Field notch Panel I� ) at Head Trim Fastener f 4 d" x "g" Pop 'a Field cubt Panel Rivet at 20 O.C. at Cold Form OR Fastener #16 12-24 x 11x" ED Pancake DP5 N W/0 Washer at V-8 O.C. at Ho. Rolled — LOGT Panel Positionn is shown with ti Panel Rib cad Cleaning on 1'-0 module. NQfn�.A!I trim is to be Location of Rib ni vary depending on O J frsialled BEFORE blanke4 the Opening Width cnnd location. Field Jry Insulation is a Ilei to walla PP measure before cuttting Panel and Trim. PBR Wali Panel - Three Sided Framed Openi ing Jamb Trim installation Fastener f4A a' x 'p" Pop Rivet at 20 O.C. at Cold Farm OR Fastener Et6 12-24x 1J' Pancake SD DP5 W/0 Washer at 1'-8 O.C. at Hot Rolled Double Sided Tape (Not ey Bldg Mfg) Blanket Insulation , PER Wall Panel -r N4b;Terminate Blanket insulation - at capi !cry lip of Jamb T.im Field flatten Trim leg when required Jamb Man F482 (shown) or Al mn.te Jamb Trim F4B4 Joamb ood Fan shown HtdoRolled similar) POptionai" G:hannel Closure Trim Slee PW07028 for details. J" EBead of HW54- Tube Caulking (Hdeoder to Floor) �\- Field Cut Wnll Panel Operrhg Width Alterna Trim F454 Profile Ngt?L Panel pckt'nni is shown with Panel Rib and Opening an V-0 module. Note:. All trim H to be Lacatlon of Rib mayy vary depend.ng an 1 Installed BEFORE blanket n the Opening Width sand Iodation. Field ie.wution Isapifore cu• tIr4 Penal and Tri m. 63 RT TTI -LE COUP AP, ROVED FOR CODE COMPLIANCE NOY 10 2016 INTERWEST m 4 The engineer whose seal appears hereon is an employee for the manufacturer for the materials described herein. Said seal or certification is limited to the products designed and manufactured by manufacturer anly.The undersigned engineer is not the overall engineer of record for this project, I G N SF ti O to O J U o +v W Jry E za<� ®❑ gp 0 al -<nz Mono M E o Z V E Qui 4 gU 00 J e F¢n w Z§01 o � 00 m Z0�p n Cp0 be v q ZN2:5 c 3 a(PNUm � Sca/e: NOT TO SCALE Drown by JOE 7/15/16 Checked by. JAM 7/15/16 Project Engineer So Job Number: 15-B-39475-1 Sheet Number.' R19 of 21 The engineer whose seal appears hereon is an employee for the manufacturer for the materials described herein. Said seal or certification is limited to the products designed and manufactured by manufacturer anly.The undersigned engineer is not the overall engineer of record for this project, I Zp y V N \FFF w j r> , m p N .. cJ o� 5j" m ( § Imo_ -i o - o w 0 J O N a c 1\ E� 0� O w E N N a O til 5 y ZE O pppA✓ �. z Arte-) d "., ff � � m co i tl [� f�✓Nl Nm..a C Q —w rte. C7 0 z n� cn o m m < mm C 0 rr. o 7m c �: -g--- ui rr D � C Z n m Z p m i p N .. cJ o� 5j" m ( § Imo_ -i o - o w 0 J O N a c 1\ E� 0� O w E N N a O til 5 y ZE O pppA✓ �. z Arte-) d "., ff � � m co i tl [� f�✓Nl Nm..a C Q —w rte. C7 0 z n� cn o m m < mm C 0 rr. o 7m c �: -g--- ui rr D � C Z n m 0 L=104.31' I' I EXISTING ORCHARD 1� N; (r O J i 1 I \ 1 (E) WELL 1; o - x x x Xx x X x— �• LIMIT OF LEACH FIELD NL o i FREE AREA AT WELL PROVIDE PERIMETER NEW CONCRETE APRON — SEDIMENT CONTROL AROUND PROJECT C)WORK AREA DURING EXIST ELECT CCCCOCU CCOO AND XFRMRS MSB CONSTRUCTION. (N) D.S. 1 � � NEW STORM DRAIN LEACH TRENCH, REFER TO DRAWINGS =' a K BY CIVIL ENGINEER P ±19'-0" �' NE tU GUAR Ht SIS '"`' EEI' ' ; SITE IMPROVMENT KEYNOTES Tc12" WIDE GUTTER BETWEEN NEW I EXISTING STORM STALL +/- 80 LF STORM DRAIN LEACH P AND EXIST. BLDGS ; DRAIN LEACH OI D IL. CONTRACTOR SHALL INSTALL 12" C' 1; TRENCH TEE TINGS AT POINTS OF CONNEC N TO GUTTER ING. 3 rE (E) WAREHOUSEI • � ,I `4 * * "� � , , , � INSTALL 12" x EDUCER A EACH TRENCH, I S -I02 6" DIAM, SOLID W HDP IPE WITH FITTINGS (E) REFRIG ' I AND COUPLINGS AS ED AND BUTTE COUNTY WAREHOUSE STANDARD ,1 S S- FLUSHING HOLE WITH CONCRETE COL AT FIN GRADE. TEMPORARY f E �I � t I, t N s� S -I E �� r E CONCRETE i F i I O INSTALL x 6" REDUCER AT LE TRENCH, WASHOUT, SEE H EXISTING CONC. I I O3 6" DIA OLID WALL HDPE PIPE WIT TINGS SHEET A-1 k iI PAD TO BE AN OUPLINGS AS NEEDED AND BUTT OUNTY REMOVED NDARD 5-22 AND 5-23 FLUSHING HOLE H RELOCATE / ; CONCRETE COLLAR AT FINISH GRADE. (E) REFUGE f 7 �, REFER TO STORM DRAIN LEACH TRENCH AREA aI ;v y s {3 s +,: EXIST. COLD ; PLAN ON 5HEET I BY CIVIL ENGINEER ---- $OX TO BE y NEW GAS METER^ " REMOVED I NEW +6' C.L. FENCED TRASH ENCLOSURE WITH PAIR LOCATION, FENC 5' GATES ON I6'-0" x 12'-O" CONCRETE SLAB ! \AROUND WIOVER GRAVEL BASE. REFER TO DETAIL OI/A-I BOLLARDS AT - lN) D.S. ; FOR PERIMETER FOOTING DETAIL. SLOPE SLAB J 1 y �t..:, _. ,1 OPENING PERP "" ° 2.0% MAX. FOR POSITIVE DRAINAGE. STANDARDS _ - - -- a' PROVIDE 8'-0" x 6" THK. CONC. APRON. ° PROVIDE BOLLARDS OR CONCRETE CURB TO -°-- (E) GAS METER PREVENT DAMAGE TO FENCING BY DUMPSTERS. 1\� I TO BE RELOCATED Q \ 5� \ I(E) OFFICE SEPTIC z I YSTEM 'B' F_ -1 q - - - - - - - - - �L - J i Ll (E) LANDSCAPING a "--(E) ACCESSIBLE PARKING STALL K � O PROVIDE SAFE DISPERSAL (E) TRUCK SCALE pF------------I AREA 50'-0" (E GRAVEL DRIVEWAY FOM BILINGPOIGN _ 1 STATING "SAFE DISPERSAL ? AREA' AT EACH LOCATION. 4 I ( TOTAL DISPERSAL AREA PROVIDED SHALL BE 350 SF O NEJ[f, E (10 OCC x 5 SF/DCC) EXISTING VERIFY SIZE OF EXISTING SCc BUILDINGS DISPERSAL AREAS. gHM 71, X l2Ei I :°vV I? FO R CODS COMIFLIANCE, X/X / USING THE FOLLOWING CODES: �`��� ❑ 2013 CAI It'ORPJIA.RESIDENTIALCODE 2013 CALIFORNIA. BUILDING CODE '� 2013 CALIFORNIA FLECRTICAL CODE R>ZO' 2013 CALIFORNIA PLUMBING CODE 2013 CALIFORNIA MECHANICAL CODE y 2013 CALII`ORNIA ENERGY CODE 2013 CALI I,ORNIAY.REEN BUILDING STAND ,.RDS CODE ❑ 2013CALIFORN1A13U1LDINGCODE - STRIIC I uUAL PROVISIONS ONLY / ❑ 2013 CALIFORNIA FIRE CODE OTHER: / COMPLETION OF THIS REVIEW DOES NOT AUTHORIZE CONSTRUCTION TO PROCEED IN VIOLATION OF ANY FEDERAL„ ' N STATE OR LOCAL REGULATIONS. _BY: PLAN - DATE: SCALE: INTERN ?ST CONSULTING �GROUP OUoP - , SITE P L4 N SCALE: "=20'-O" O' 50' 100' 10' 200' 250' 500'( O' 10' 20' 50' 40' 50' 60' 6,mod m SCOPE OF WORK CODE ANALYSIS SHEET INDEX (E) GRAVEL DRIVEWAY NOTE: PROJECT SHALL COMPLY WITH BUTTE COUNTY STORMWATER MANAGEMENT AND EROSION CONTROL ORDINANCES, REFER TO SHEET A-1 FOR SITE BMP'S MINIMUM EROSION AND SEDIMENT CONTROLS NOTES. I I �I � _I VIII II I I SHEET a SHEET CONTENTS A -I SHEET INDEX, CODE ANALYSIS, VICINITY MAP, SCOPE OF WORK OVERALL SITE PLAN ENLARGED SITE PLAN o OVERALL FLOOR PLAN - AS BUILT 1/8" SCALE A-3 I OVERALL FLOOR PLAN - ADDITION 1/8" SCALE A-4 FLOOR PLAN - ADDITION 1/4" SCALE A-5 EXTERIOR ELEVATIONS -6SECT N CU S, RO FPL ry O" MINIMUM EROSION AND SEDIMENT CONTROLS NEW METAL BUILDING ADDITION TO EXISTING FACILITY. CODE: 2013 CALIFORNIA BUILDING CODE ALLOWABLE AREA: BASIC: S-1 STRUCTURAL NOTES S-2.0 ---------- - - - - -- FOUNDATION DETAILS 5-2.2 FOUNDATION DETAILS 2013 CALIFORNIA FIRE CODE B = 9,000 SF F I = 8,500 SF 1 E-24 T24 ENERGY COMPLIANCE FORMS y ENERGY COMPLIANCE FORMS 1 STORM DRAIN LEACH TRENCH PLAN CONSTRUCTION: V -B, NON-SPRINKLERED S-1 = 9,000 SF CHAIN LINK FENCING BUILDING NOT HEATED OR COOLED W/ INCREASE: o SPECIAL INSPECTIONS Ir = (5l0/Sl0 - :25) 60/30 = 1.5 OCCUPANCY/USE: B OFFICE A5 = AT !+ I AT x lr 1 + f AT x I5 1 F -I PROCESSING B 9,000 + (q,p00 X L5 ) ° REFER TO STRUCTURAL NOTES ON SHEET S -I FOR S -I STORAGE = 22,500 SF SPECIAL INSPECTION INFORMATION. EXIT DISTANCE: B 200 LF MAX F-1 8,500 + ( 8,500 X 1.5 ) 6" THICK CONIC SLAB F -I 200 LF MAX = 21,250 SF 44 BARS AT 24" O.0 8-1 200 LF MAX 8-1 9,000 + ( 9,000 X I.5 ) C) EACH WAY } = 22.500 SF REFER TO SHEET A-3 FOR ACTUAL I GRAVEL BASE TRAVEL DISTANCE TO NEAREST EXIT. ACTUAL AREA: MIXED OCCUPANCY Fp OCCUPANT LOAD: B 1526 SF / 100 = 14 OCCUPANTS (E) B 1,526 SF FINISH e C,B,C, 11B-202 COMPLIANCE F -I 3.360 SF / 100 = 34 OCCUPANTS (E) F -I 3,360 SF w GRADE S-1 9,982 SF / 500 = 20 OCCUPANTS (N) S-1 5,002 SF Q °... 1 TOTAL OCCUPANT LOAD = 10 (E) S -I 4,980 SF NATURAL GRADE= a o 0 yoy8 IT IS THE INTENTION OF THE PROPOSED SCOPE OF WORK TO ENSURE THAT THE SUBJECT EXISTING MEET THE ACCESSIBILITY REQUIREMENTS OF TH 2013 ALIFORNIA 2 EXITS REQUIRED, 4 EXITS PROVIDED REFER TO SHEET A-3 FOR LOCATIONS TOTAL: 14,866 SF EXIST B EXIST F -I EXIST 5-I NEW S -I v. BUILDING CODE. SECTION IIB -202 "ACCESS OR OF EXIT S i _ PROPOSED 1,526 - 3.360 4,980 5,002 w III—III VARIOUS AREAS OF THE EXISTING ACCESSIBLE PARKING PROVIDED: 'B" OFFICE: ....................1,526 / 300 = 5 STALLS 22,500 + 21,250 + 22,500 + 22,500 ACCORDING TO THE "PRIORITY LIST" DESCRIBED IN THE T-1" PROCESSING:.......3,360 / 1,250 = 3 STALLS I � I' SAID CODE, AND IS DESCRIBED IN THE FOLLOWING _ 0.068 + 0.158 +0.221 +0.222 = 0.669G 1 OK SUMMARY OF WORK. �..�82. /.1.812. tt4 BAR TOP ACCESSIBLITY IMPROVEMENTS TO EXISTING FACILITY MADE TOTALPARKINGREQ D.. 13STALLS AND BOTTOM UNDER PRIOR PERMIT. PARKING PROVIDED: A.C. PARKING LOT WITH I VAN ACCESSIBLE ALL NEW WORK SHALL BE ACCESSIBLE. PARKING STALL AND 3 STANDARD STALLS r AND GRAVEL PARKING AREA. OI TRASH E ENCLOSURE PERIMETR o A-1 SCALE: 1" - 11-01, I 77� 7777 I I �I � _I VIII II I I SHEET a SHEET CONTENTS A -I SHEET INDEX, CODE ANALYSIS, VICINITY MAP, SCOPE OF WORK OVERALL SITE PLAN ENLARGED SITE PLAN A-2 OVERALL FLOOR PLAN - AS BUILT 1/8" SCALE A-3 I OVERALL FLOOR PLAN - ADDITION 1/8" SCALE A-4 FLOOR PLAN - ADDITION 1/4" SCALE A-5 EXTERIOR ELEVATIONS -6SECT N CU S, RO FPL 1 A-1 CALGREEN MANDATORY MEASURES MINIMUM EROSION AND SEDIMENT CONTROLS AC -I ACCESSIBILITY DETAILS S-1 STRUCTURAL NOTES S-2.0 FOUNDATION PLAN S-2.1 FOUNDATION DETAILS 5-2.2 FOUNDATION DETAILS E - I ELECTRICAL PLAN, PANELS, ONE LINE DIAGRAM 1 E-24 T24 ENERGY COMPLIANCE FORMS E -29-'T24 ENERGY COMPLIANCE FORMS 1 STORM DRAIN LEACH TRENCH PLAN r f� 10 PERMIT# fel '' BUTTE ��- BUTTECOU ELOPMENTSERVICES COUNTY j -c VIEWED FOR Ij{ CODE COMPLIANCE OCT 2 5 2016 DATE- lLj�?(�_BYZ DEVELOPMENT SERVICES VICINITY MAP PROJECT 51TE DURHAM DAYTON HWY O 16 N a, DURHAM ,3F Revisions: 10/24/2016 PLAN CHECK 1 'lot Date: 10/24/20161 Date: 10-2014 Drawn: GC Job No: 15-051 y Q Sheet: j of: L(l N Q 0 w r - C, 0 i iw z Q ILL] Q 0 I w J LL 0 Q - U Q H a 0 0 a U ri _ � y ____ _ I I1 . ,_ I 911 T �- T w BUILDING AREA ____ _ I I1 . ,_ I 911 T �- T w I 1 NEW BUILDING C .........................................5,002 Square Feet DATE,tl -�.- =1� BY_ DRY STORAGE Date: 10-2016 Drawn: GC Job No: 15-051 REVIEWED FOR CODE COMPLIANCE NOV io 2016 FLOOR PLAN INTERWEST ASBUILT/1 EMO CONSULTING GROUP N SCALE: 0' 2' 4 6' l,jr _ _ TI 11:111�� �� BUILDING AREA 00 c E (E) BUILDING 'A' ......................................... 4,886 Square Feet a0) N U U Square Feet 0 z PACKING/PROCESSING: ................................ 3,360 Square Feet Q (E) BUILDING 'B' .......................................... 4,980 Square Feet V Q '' l PERMIT V' REFRIG. WAREHOUSE: .................................... 3,280 Square Feet BUTTE COUNTY DEVELOPMENT SERVICES ENCLOSED CANOPY: ..................................... 1,100 Lo REVIEWED FOR 7 F ) � V ¢ It) La in 4U 0 V M U I 1 NEW BUILDING C .........................................5,002 Square Feet DATE,tl -�.- =1� BY_ DRY STORAGE Date: 10-2016 Drawn: GC Job No: 15-051 REVIEWED FOR CODE COMPLIANCE NOV io 2016 FLOOR PLAN INTERWEST ASBUILT/1 EMO CONSULTING GROUP N SCALE: 0' 2' 4 6' l,jr _ _ TI 11:111�� �� BUILDING AREA (E) BUILDING 'A' ......................................... 4,886 Square Feet ry OFFICE: ......................................................... 1,526 Square Feet z PACKING/PROCESSING: ................................ 3,360 Square Feet Q (E) BUILDING 'B' .......................................... 4,980 Square Feet '' l PERMIT REFRIG. WAREHOUSE: .................................... 3,280 Square Feet BUTTE COUNTY DEVELOPMENT SERVICES ENCLOSED CANOPY: ..................................... 1,100 Square Feet REVIEWED FOR CODE COMPLIANCE I 1 NEW BUILDING C .........................................5,002 Square Feet DATE,tl -�.- =1� BY_ DRY STORAGE Date: 10-2016 Drawn: GC Job No: 15-051 REVIEWED FOR CODE COMPLIANCE NOV io 2016 FLOOR PLAN INTERWEST ASBUILT/1 EMO CONSULTING GROUP N SCALE: 0' 2' 4 6' l,jr _ _ TI 11:111�� �� O ry LIJ Ltj z LL J 7- i O x m I 1 NEW BUILDING C .........................................5,002 Square Feet DATE,tl -�.- =1� BY_ DRY STORAGE Date: 10-2016 Drawn: GC Job No: 15-051 REVIEWED FOR CODE COMPLIANCE NOV io 2016 FLOOR PLAN INTERWEST ASBUILT/1 EMO CONSULTING GROUP N SCALE: 0' 2' 4 6' l,jr _ _ TI 11:111�� �� O 3 O A I 1 A-6 i 82'-0" (N) S -I �6, A tNt3lO/ ! . • ' ' • • (N�I MAN DOOR MAINTAIN 44" CLEAR • , . • ' ' I PATH OF EGRESS / TRAVEL TO BUILDING . • ' I NEW CONCRETE EXITS... • ' I SLAB FLUSH W/ o . • ' (N) 12x12 I BUILDING SLAB j I . • . •' ROLL UP - j MAX B' i / t (E) LOUVER A "10' VENTP B (E) AIR N COMP. AUTOMATED ( 0( (E) SUB PANEL ROLL -UP DR / ' • , (E) OFFICE 2 (E) OFFICE 3 (E) OFFICE 4 • • • . B Es B / 49' TO ' . 1 m o EXIT I I1 -01 (E) PACKING '•, I 1 W a ED r---- WAREHOUSE° ❑ • (E) / ' • :' (E) PROCESSINGI AREA m ----u OF.E. / F -I III F -I -----" (E) ELECT • .. 0j PANEL ..... (E) HALL 3 w (E)EELECT ° U III B ��� PANEL ° 0 (E) RECEPTION (E) MEN'S ❑ I 1 =i j FkT� 01ST Z a (E) BREAK O ' • , (E) O $ A ia fl (E) WMN'S 50To • 1 ' • , (E) PORCH (E)r EXIT ®. 1 • • ' 3068Frrq '. -----------____------ -_-__.—L -- 1 1 (E) 8'x10' FL IBLE AUTOMATED ; 1 ROLL -UP D R (E) 30101 NEW CONCRETE SLAB W1A � I BUILDINGUSLAB A-6 (E (E) WAREHOUSE No (E) s -I ! A xft- MAX MAX (E) 1 1 .. 3010 1 (E) 12' SLIDER ' 0 0 0 N P I lE)'. • • I 1 3010 • , o LU it • , I I I NO PARKING . • • I u�. •, 1 ' • . , (E) REFRIG WAREHOUSE I . � w V • TO FkF� OAST w 1 • . 9�%�NCF I 1 1 o I LH ,• 1 � I • I o ' Q 0 0 a U N — 4" WALL BUTTE COUN DEVELOPMENT SERVICES RE IEWED FOR CODE OMPLIANCE DAYE—U-- 15_1. BY a__ EQUIPMENT OR ACCESSORIES, NAILING OR BACKING. 3. REGARDLESS OF THE OCCUPANT LOAD SERVED, EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF FOR CODE COMALI Revisions: Nov 10 2016 4. REFER TO DETAILS FOR ACCESSIBILITY REQUIREMENTS 10/24/2016 HARDWARE/KICK PLATES: 2 / AC -1 CLEAR OPENING: 3 / AC -1 PLAN CHECK THRESHOLDS: 5 / AC -1 LEVEL LANDING (EXTERIOR): 6 / AC -1 ACCESSIBILITY SIGNAGE ITEMIt DESCRIPTION DETAIL LV�r U U `TA T4LE:EXITmSIGN 12 / ACTI•' V ® TACTILE EXIT ROUTE SIGN 12 / AC -1 Plot Date: 10/24/2016 — FRAMING LEGEND. 4" WALL BUTTE COUN DEVELOPMENT SERVICES RE IEWED FOR CODE OMPLIANCE DAYE—U-- 15_1. BY a__ EQUIPMENT OR ACCESSORIES, NAILING OR BACKING. 3. REGARDLESS OF THE OCCUPANT LOAD SERVED, EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF FOR CODE COMALI UNLATCHING OF ANY DOOR OR LEAF SHALL NOT REQUIRE Nov 10 2016 4. REFER TO DETAILS FOR ACCESSIBILITY REQUIREMENTS INTEST CONSULTING EGRO HARDWARE/KICK PLATES: 2 / AC -1 CLEAR OPENING: 3 / AC -1 LEVEL MANEUVERING CLEAR SPACE: 4 / AC -1 FRAMING LEGEND. 4" WALL ��� 6" WALL 8" GIRT WALL NEW WALLS SHOWN SHADED, TYPICAL. GENERAL NOTES I. NEW WALL FRAMING SHALL BE METAL Z-GIRTS WITH METAL WALL PANELS, BY OTHERS. REFER TO DRAWINGS BY METAL BUILDING MANUFACTURER. 2. PROVIDE BLOCKING AS REQUIRED FOR WALL MOUNTED EQUIPMENT OR ACCESSORIES, NAILING OR BACKING. 3. REGARDLESS OF THE OCCUPANT LOAD SERVED, EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT AND THE UNLATCHING OF ANY DOOR OR LEAF SHALL NOT REQUIRE MORE THAN ONE OPERATION. 4. REFER TO DETAILS FOR ACCESSIBILITY REQUIREMENTS AT DOORS: HARDWARE/KICK PLATES: 2 / AC -1 CLEAR OPENING: 3 / AC -1 LEVEL MANEUVERING CLEAR SPACE: 4 / AC -1 THRESHOLDS: 5 / AC -1 LEVEL LANDING (EXTERIOR): 6 / AC -1 ACCESSIBILITY SIGNAGE ITEMIt DESCRIPTION DETAIL LV�r U U `TA T4LE:EXITmSIGN 12 / ACTI•' V ® TACTILE EXIT ROUTE SIGN 12 / AC -1 �r Ir BUILDING AREA (E) BUILDING 'A' ......................................... 4,886 Square Feet OFFICE: ......................................................... 1,526 Square Feet PACKING/PROCESSING: ................................ 3,360 Square Feet (E BUILDING 'B' .......................................... 4,980 Square Feet REFRIG. WAREHOUSE: .................................... 3,280 Square Feet ENCLOSED CANOPY: ..................................... 1,100 Square Feet NEW BUILDING 'C' .........................................5,002 Square Feet DRY STORAGE NCE OVERALL FLOOR PLAN ADDITION SCALE: 1/8"=1'-0" )P 0' 2' 9' 6' 8' I6' " V I I I I c�NSED Rc&l * i�fi,93 RE l P LH IL z z Lu T9TF � CAUF��\ V ,O,\\ V L-1 < m Date: 10-2016 Drawn: N 1 O N U ro u a cn � Qa In m m cn O1in N. CD LV�r U U V Q Rv� `n o V M U c�NSED Rc&l * i�fi,93 RE l P LH IL z z Lu T9TF � CAUF��\ V ,O,\\ V L-1 < m Date: 10-2016 Drawn: GC Job No: 15-051 A J A-6 21'-4" .4dt , u , v a ". Z-GIRTS, REFER TO DRAWINGS BY METAL BUILDING MANUFACTURER NEW 2AIOBC FIRE EXT. i I 0 j j (N) 3010 MAN DR, EXISTING Z-GIRTS EXISTING FULL HEIGHT 2x FRAMED WALL (E) SUBPANEL I _ _ _ _ (E) 3' X 2' LOUVER, NG METAL I TOP AT +18'-0" VG FRAME A 0 DOUBLE STACK OVEN 0 DOUBLE STACK OVEN FRAMING LEGEND 4" WALL I\7C7\l 6" WALL 8" GIRT WALL NEW WALLS SHOWN SHADED, TYPICAL. GENERAL NOTES I. NEW WALL FRAMING SHALL BE METAL Z-GIRTS WITH METAL WALL PANELS, BY OTHERS. REFER TO DRAWINGS BY METAL BUILDING MANUFACTURER. 2. PROVIDE BLOCKING AS REQUIRED FOR WALL MOUNTED EQUIPMENT ;OR ACCESSORIES, NAILING OR BACKING. 3. REGARDLESS OF THE OCCUPANT LOAD SERVED, EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT AND THE UNLATCHING OF ANY DOOR OR LEAF SHALL NOT REQUIRE MORE THAN ONE OPERATION. 4. REFER TO DETAILS FOR ACCESSIBILITY REQUIREMENTS AT DOORS: HARDWARE/KICKPLATE S: 2 / AC -1 CLEAR OPENING: 3 / AC -1 LEVEL MANEUVERING CLEAR SPACE: 4 / AC -1 THRESHOLDS: 5 / AC -1 LEVEL LANDING (EXTERIOR): 6 / AC -1 ACCESSIBILITY SIGNAGE ITEM# DESCRIPTION DETAIL A '. TAG f(Lg, EkI,7, SIGN „ (Bi TACTILE EXIT ROUTE SIGN 12 / AC -1 I PERMITi#66t rk / lD BUTTE COUNTY DEVELOPMENT SERVICES r' REVIEWED FOR � CODE COMPLIANCE PATE 4(t.....�.�—__..- 12" FRAME SEPARATION BUILDING AREA FOR GUTTER m (E) BUILDING 'A' ......................................... 4,886 Square Feet A OFFICE: ......................................................... 1,526 Square Feet PACKING/PROCESSING: ................................ 3,360 Square Feet �_ (E) BUILDING 'B' ..... 4,980 Square Feet (E) AIR ........................... COMPRESSOR REFRIG. WAREHOUSE ........................... 3,280 Square Feet ENCLOSED CANOPY: ..................................... 1,100 Square Feet NEW BUILDING 'C' .........................................5,002 Square Feet DRY STORAGE ;EVIEWED rE) O FOR ODE COMPLIANCE XMFR NOV 16 2616 0 INTERWEST FLOOR PLAN uLTI ^ '� ADDITION (E) 800A 480V N 3PH 4W MSB SCALE: NEMRA 3R O I' 2' 3 4 8 C) I 0 Revisions: 10/24/2016 PLAN CHECK V O o U LU U N U CDU I I FLUSH 0 LL 1F -1---N CONCRETE O w T APRON Q < a m v�J 0 oo MOX o 0 M DO I cin i SNI m i r ox I CONFIRM SIZE OF Ww I a' n EXISTING DOOR �,,N rn W TO BE RELOCATED X'01 1 v U wl V M U EXISTING Z-GIRTS EXISTING FULL HEIGHT 2x FRAMED WALL (E) SUBPANEL I _ _ _ _ (E) 3' X 2' LOUVER, NG METAL I TOP AT +18'-0" VG FRAME A 0 DOUBLE STACK OVEN 0 DOUBLE STACK OVEN FRAMING LEGEND 4" WALL I\7C7\l 6" WALL 8" GIRT WALL NEW WALLS SHOWN SHADED, TYPICAL. GENERAL NOTES I. NEW WALL FRAMING SHALL BE METAL Z-GIRTS WITH METAL WALL PANELS, BY OTHERS. REFER TO DRAWINGS BY METAL BUILDING MANUFACTURER. 2. PROVIDE BLOCKING AS REQUIRED FOR WALL MOUNTED EQUIPMENT ;OR ACCESSORIES, NAILING OR BACKING. 3. REGARDLESS OF THE OCCUPANT LOAD SERVED, EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT AND THE UNLATCHING OF ANY DOOR OR LEAF SHALL NOT REQUIRE MORE THAN ONE OPERATION. 4. REFER TO DETAILS FOR ACCESSIBILITY REQUIREMENTS AT DOORS: HARDWARE/KICKPLATE S: 2 / AC -1 CLEAR OPENING: 3 / AC -1 LEVEL MANEUVERING CLEAR SPACE: 4 / AC -1 THRESHOLDS: 5 / AC -1 LEVEL LANDING (EXTERIOR): 6 / AC -1 ACCESSIBILITY SIGNAGE ITEM# DESCRIPTION DETAIL A '. TAG f(Lg, EkI,7, SIGN „ (Bi TACTILE EXIT ROUTE SIGN 12 / AC -1 I PERMITi#66t rk / lD BUTTE COUNTY DEVELOPMENT SERVICES r' REVIEWED FOR � CODE COMPLIANCE PATE 4(t.....�.�—__..- 12" FRAME SEPARATION BUILDING AREA FOR GUTTER m (E) BUILDING 'A' ......................................... 4,886 Square Feet A OFFICE: ......................................................... 1,526 Square Feet PACKING/PROCESSING: ................................ 3,360 Square Feet �_ (E) BUILDING 'B' ..... 4,980 Square Feet (E) AIR ........................... COMPRESSOR REFRIG. WAREHOUSE ........................... 3,280 Square Feet ENCLOSED CANOPY: ..................................... 1,100 Square Feet NEW BUILDING 'C' .........................................5,002 Square Feet DRY STORAGE ;EVIEWED rE) O FOR ODE COMPLIANCE XMFR NOV 16 2616 0 INTERWEST FLOOR PLAN uLTI ^ '� ADDITION (E) 800A 480V N 3PH 4W MSB SCALE: NEMRA 3R O I' 2' 3 4 8 C) I 0 Revisions: 10/24/2016 PLAN CHECK Date: 10-2016 Drawn: GC Job No: 15-051 Sheet: QA of: V O o U LU U N U CDU a 0 LL 1F -1---N O w T Ir Q < a m v�J M cin m I -- U) W N a' n to rn W (�( UU v U V M U Date: 10-2016 Drawn: GC Job No: 15-051 Sheet: QA of: V O v LU LL 1F -1---N O T < I m Date: 10-2016 Drawn: GC Job No: 15-051 Sheet: QA of: t5t I WttN BUILDINGS I i 1 , I i I I I I I I I I . .. . . NEW CONC. APRON (E) BUILDING °g" (E)CANOPYED (E) BUIL ING "A" REAR ELEVATION SCALE: 2 3 1 NEW SCREW—DOWN METAL ROOFING PANELS LIGHT TRANSMITTING PANELS i I +19'-1" EAVE I NEW METAL SIDING +6" CURB I +0'-0" FINISH FLOOR ---- ---------------------------------------------- ---------------- NEW BUILDING „IC„ LEFT ELEVATION - DAYTON ROAD SCALE:.I/8"=I'-O.. I I B A NEW METAL RO FING PANELS (E) METAL ROOFING u; 12 (E) METAL SIDING Ili I 1 IT 7 il 1'I I i (' En T—(N) BUILDING SLAB +/- 5" ABOVE (E) ADJACENT SLAB B C D i +0 CURB I I +0'-0" FINISH FLOOR AT NEW BUILDING 'C' FLUSH LEVEL LANDING AT MAN DOORS —0'-5" FINISH FLOOR AT TE) BLDG 'A' NEW BUILDING "C', (E) ENCLOSED CANOPY (E) COMP. ROOFING NEW METAL SIDING AT REMOVED MAN DOOR (E) BUILDING "A" (E) BUILDING "B" PERMIT #_6 BUTTE COUNTY DEVELOPMENT SERVICES N U O NU cn 03 U O = m r, vel m � � m Q w r, L (n cn U U Qq U0 V M U �NSF,D ARCy/T o +19'-1" EAVE AR 3 RE �TgTF OF CAIFF��\P O,\ V 1 0 LLI I'— 11 IV— LL z III II 0 tt LLI _ �m ' 1 o I NEW METAL SIDING I I � i I P- W ❑J j iY Lu m F- N 1 o +6CURB _ " i +0'-0" FINISH FLOOR — W---------------'----------------------- - z Lu NEW BUILDING "C" (E) BUILDING "A" 0 CIO FRONT ELEVATION - HEGAN LANE o SCALE: Q Q 0 / 0 a v / N Ili I 1 IT 7 il 1'I I i (' En T—(N) BUILDING SLAB +/- 5" ABOVE (E) ADJACENT SLAB B C D i +0 CURB I I +0'-0" FINISH FLOOR AT NEW BUILDING 'C' FLUSH LEVEL LANDING AT MAN DOORS —0'-5" FINISH FLOOR AT TE) BLDG 'A' NEW BUILDING "C', (E) ENCLOSED CANOPY (E) COMP. ROOFING NEW METAL SIDING AT REMOVED MAN DOOR (E) BUILDING "A" (E) BUILDING "B" PERMIT #_6 BUTTE COUNTY DEVELOPMENT SERVICES N U O NU cn 03 U O = m r, vel m � � m Q w r, L (n cn U U Qq U0 V M U REVIEWED FOR Date: 10-2 CODE COMPLIANCE DATE 4,J ffIt BY__ Drawn: GC Job No: I9-051 REVIEWED FOR CODE COMPLIANCE NOV 10 2016 INTERWEST CONSULTING GROUP Sheet: Ams of; �NSF,D ARCy/T * AR 3 RE �TgTF OF CAIFF��\P O,\ V 1 0 LLI I'— 11 IV— LL z III II 0 tt LLI �m REVIEWED FOR Date: 10-2 CODE COMPLIANCE DATE 4,J ffIt BY__ Drawn: GC Job No: I9-051 REVIEWED FOR CODE COMPLIANCE NOV 10 2016 INTERWEST CONSULTING GROUP Sheet: Ams of; tr.i____L- I A 6 Q I i t f c k I s � Cx, NEW METAL ROOFING PANELS x :, '� r 2 a z REFER TO DRAWINGS BY r METAL BUILDING MANUFACTURER t! 7 a ! l t n tf �, r 2 a SCREW DOWN TYPE A D 'f[ k ti 5" f y§ W� Z Ito k i t 2 Zt k � 1l It uJ !,� "!' IIt!Fs 1{({ �.4. �s a 4,1 ai� ,, kfs ,. i X; a t� f a, r, tytf � � #kvttitk° k hriii,021y- s 7 i. Mh } 3 >3 LIGHT TRANSMITTING PANELS SEE METAL BUILDING PLAN$, I ,! f ai .- ,YXX� �'. �1�•'Y. afi s -5t +EI S,!i� rs r ¢ � ''� `af :y'z 1 � � r€}i ut Rt lii �It' a ,s ,n Q t xx ; (E) GUTTER 3 — �+D J' O x (E) ARCHITECTURAL ^ 5u� Q COMPOSITION ROOFING r, I E (E) METAL ROOFING (E) Z-GIRTS ;v K (E) PACKING 0, 1 NEW METAL BUILDING (E) GUTTER EXISTING GUTTER I A I NEW ROLL -UP DOOR AT I i A-6 REMOVED COLD BOX OPEN'G I (E) METAL ROOFING 1 I I I +6 CURB BEYOND EXISTING WAREHOUSE F (E) METAL ROOFING j CONCRETE SLAB ---1 -_5% SLOPE ROOF PLAN - (N) WAREHOUSE SLABIlk f k lv SCALE: 5'-6" 8`-6" +5" ABOVE XISTING n (N) LEVEL LANDING � #r 3 "t� Iv"I FLUSH W/ (E) O' 8' I6' 24' 32' 64' WAREHOUSE SLAB I I I I I I I SECTION I1g)l SCALE: 1/4"=1'-0" QA)B C U (E) METAL ROOFING CLEAR BETWEEN NEW GUTTER 1,-0" I NEW METAL ROOFING (E) INSULATED 12" WIDE x 8" DP STEEL LINES SCREW DOWN CEILING W/ 6" DIA. ( 12 r PVC DOWNSPOUTS � >, �X',.rXkti nx F r , <,�, 12 x, ll �Xr,'�'1 .. -:, y,�'a rcr Y.v ts:s�ik�'Y,,;t').k✓}F X'a'Xkfy:�t v ..X1 .:t ;y, - .,. ,... � h.. '1 .�,, ... .,. -.v {... 'YY�zX�A.����x�/./.7J'k. s'�. .r.inYYv'it`\;.;r...<Y:.> ;.Z „r,X,7nFr•k•x'v - f ti;.;{_Y n-_,....._XuY ln:. xrji`✓k.1,x'i?:fYty X nXX'S,:tl} - .XYa' g ti 5 --, NSULAYTION TYP. , (E) FRAMED WALL— E) ALL E) Z-GIRTS NEW STEEL FRAME (E) METAL SIDING I r. I (E) Z-GIRTS EXISTING METAL SIDING TO REMAIN II w (E) 2x FRAMED WALL FROM SLAB (PROVIDE ALT BID TO REPLACE TO BOTTOM OF CEILING. , I i OF METAL FRAME X BRACING. (E) PROCESSING WITH PLYWOOD) NEW METAL BUILDING r , `,- a (E) WAREHOUSE � REFER TO DRAWINGS BY � '` - METAL BUILDING MANUFACTURER FOR ADDITIONAL INFORMATION. uj ri Z-GIRTS (E) 3/8" PLYWOOD FLOOR TO CEILING I (E) F.R.P. TO +8' A.F.F. i u NEW CONCRETE SLAB N h; (E) 6" HIGH CONC. CURB, EXISTING +6" I METAL FRAME ON +6" SET I" BELOW TOP OF 8" WIDE x 6" HIGH CONCRETE CURB >> (E) CONC SLAB PEDESTAL/CURB ! EXISTING CONCRETE CURB CONC CURB TYPICAL AT ADJACENT BUILDING �11 V PERMIT# I BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR REVIEWED COMPLIANCE DATE FOR CODE COMPLIANCE SECTION "Alli �-(S,CG � _BY , u � SCALE: NOV INTERWEST CONSULTING GROUP ReV151on5: 10/24/2016 PLAN CHECK I Plot Date: 10/24/2016 Date: 10-2016 Drawn: GC Job No: 15-051 Sheet: Acmis of: O i V O U Nu cV O N U O U oIL � z Z V C1 Ln LLI vW M w ) Q m w Ln N O) ULf) � 0 Qp^ 4Y V M U Date: 10-2016 Drawn: GC Job No: 15-051 Sheet: Acmis of: V 101 V Nu 1-1--1 oIL � z Z V rr � LLI Date: 10-2016 Drawn: GC Job No: 15-051 Sheet: Acmis of: TEMPORARY CONCRETE WASHOUT STAKE (TYPICAL) SIT MUS AND SIDEWALKS AND AT LEAST 50' FROM THE NEAREST STORM DRAIN NET FF VF STREETS ACCORDANCE WITH SECTION SA08.1.1, 5.408.2 OR 5.408.3; "— WIRENC r ❑ 10 MIL PLASTIC LINING * G.C. TO DETERMINE SIZE OF CONCRETE WASHOUT. MINIMUM EROSION AND SEDIMENT CONTROLS ❑ ❑ ❑ ° ° REFER TO SHEET A-1 FOR LOCATION OF NEW TRASH THE BMP'S (BEST MANAGEMENT PRACTICES) LISTED BELOW MUST BE IN PLACE DURING THE NON-RESIDENTIAL MANDATORY MEASURES - DIVISIONS ENCLOSURE. OR EQUIVALENT SIT MUS AND SIDEWALKS AND AT LEAST 50' FROM THE NEAREST STORM DRAIN NET FF VF STREETS ACCORDANCE WITH SECTION SA08.1.1, 5.408.2 OR 5.408.3; "— WIRENC r OR MEET A LOCAL CONSTRUCTION AND DEMOLITION B MINIMUM EROSION AND SEDIMENT CONTROLS WASTE ORDINANCE, WHICHEVER IS MORE STRINGENT. 2013 GREEN CODE COMPLIANCE DRYWALL MUD BOXES, PAINT BUCKETS, CLEANING MATERIAL CONTAINERS ETC. COME IN REFER TO SHEET A-1 FOR LOCATION OF NEW TRASH THE BMP'S (BEST MANAGEMENT PRACTICES) LISTED BELOW MUST BE IN PLACE DURING THE NON-RESIDENTIAL MANDATORY MEASURES - DIVISIONS ENCLOSURE. OR EQUIVALENT RAINY SEASON (OCTOBER 15 THROUGH APRIL IS) AND MAY BE REQUIRED AT OTHER TIMES 5.410.1 RECYCLING BY OCCUPANTS Bond breakers VISQUEEN MAY BE USED FOR THIS APPLICATION. ROLL -AWAY BINS MAY ALSO BE USED. REFER TO SITE PLAN FOR LOCATION OF NEW TRASH BASED ON WEATHER AND SITE CONDITIONS THROUGHOUT THE YEAR. THE BMP'S LISTED ARE 5.106.1 REFER TO 'MINIMUM EROSION AND SEDIMENT CONTROLS' Driveway sealers 50 MINIMUM REQUIREMENTS AND ADDITIONAL BMP'S COULD BE REQUIRED BASED ON SITE CONDITIONS. 150 NOTES FOR STORM WATER POLLUTION PREVENTION MEASURES. O.S" LAG SCREWS Fire resistive coatings. 1. ALL SOILS TRACKED ONTO PAVED ROADWAYS MUST BE CLEANED UP ON A DAILY BASIS. 5.106.4 BICYCLE PARKING: N/A - NOT ADDING ANY NEW PARKING Form -release compounds OPENINGS MUST BE COVERED UNTIL FINAL STARTUP OF WHEN STREETS ARE WET OR DURING A RAIN EVENT THERE SHALL BE NO TRACKING OF 10. COORDINATE WITH LOCAL BUILDING OFFICIAL FOR ANY ADDITIONAL REQUIREMENTS HEATING AND COOLING SYSTEM. N/A - NEW BUILDING NOT 420 SPECIFIC TO JURISDICTION AND SITE. SOILS ONTO THE STREET. 5.106.5.2 CLEAN AIR VEHICLE PARKING: N/A - NOT ADDING ANY PLYWOOD 48"x24"NEW STEEL r Mastic texture coatingis 5 504 4- FINISH PARKING. PAINTED WHITEPRedEeT_ Multicolor coatings Pretreatment wash primers 420 Primers, sealers, and undercoaters 100 SITE. 5.303.2 WATER REDUCTION. N/A - NO PLUMBING FIXTURES BLACK LETTERS Roof coatings 50 Rust preventative coatings 250 6" HEIGHT -150 550 Specialty rimers, sealers, and undercoaters 5.303.3 WATER CONSERVING PLUMBING FIXTURES AND FITTINGS. 250 Stone consolidates 1. TRA5FI 15ARt #CROlt THE BACK OF #171! !)RAIN llqtf!T5. Swimming pool coatin s N/A - NO PLUMBING FIXTURES WOOD POST 100 NO DRAIN INLETS WITHIN ISO' OF PROJECT SITE. 5.303.6 PLUMBING FIXTURES AND FITTINGS - N/A - NO NEW 3" x 3" x 8'-0" Wood coatings 215 Wood preservatives PLUMBING FIXTURES PROPOSED UNDER THIS PROJECT. Zinc -rich primers 540 S. ALL PAINT, FUEL, CONSTRUCTION PRODUCTS ETC. SHALL BE STORED IN A COVERED 5.408.1 CONSTRUCTION WASTE MANAGEMENT LOCATION AWAY FROM SIDEWALKS AND STORM DRAIN INLETS RECYCLE AND/OR SALVAGE FOR REUSE A MINIMUM OF M U 6 PORTABLE CHEMICAL TOILETS IF PROVIDED ON 50% OF THE NON -HAZARDOUS CONSTRUCTION WASTE IN MATERIALS I L AND SIDEWALKS AND AT LEAST 50' FROM THE NEAREST STORM DRAIN NET FF VF STREETS ACCORDANCE WITH SECTION SA08.1.1, 5.408.2 OR 5.408.3; "— WIRENC r OR MEET A LOCAL CONSTRUCTION AND DEMOLITION B 1. ALL TRASH MUST BE COLLECTED AND STORED PROPERLY. DO NOT LET ITEMS SUCH AS WASTE ORDINANCE, WHICHEVER IS MORE STRINGENT. CONCRETE WASHOUT SIGN DRYWALL MUD BOXES, PAINT BUCKETS, CLEANING MATERIAL CONTAINERS ETC. COME IN REFER TO SHEET A-1 FOR LOCATION OF NEW TRASH Basementspecialty coatings CONTACT WITH ANY RAINFALL OR STORM WATER RUNOFF. ENCLOSURE. OR EQUIVALENT 8. PROVIDE A DESIGNATED AREA FOR CONCRETE WASHOUT. HAY BALES LINED WITH 5.410.1 RECYCLING BY OCCUPANTS Bond breakers VISQUEEN MAY BE USED FOR THIS APPLICATION. ROLL -AWAY BINS MAY ALSO BE USED. REFER TO SITE PLAN FOR LOCATION OF NEW TRASH 550 ALL CONCRETE WASHOUT SYSTEMS SHALL BE PLACED OFF OF PAVED STREETS. ENCLOSURE. OCCUPANT TO COMPLY WITH LOCAL Driveway sealers 50 RECYCLING ORDINANCES AS REQ'D BY BUTTE COUNTY. 150 9. AFTER INSTALLATION OF THE ABOVE ITEMS IS COMPLETE A MAINTENANCE PROGRAM 550 Fire resistive coatings. NEEDS TO BE DEVELOPED TO INSURE THE CONTINUED EFFECTIVENESS OF YOUR BMP'S. 5.504.3 ALL DUCT OPENINGS AND OTHER RELATED DISTRIBUTION 100 Form -release compounds OPENINGS MUST BE COVERED UNTIL FINAL STARTUP OF -2 10. COORDINATE WITH LOCAL BUILDING OFFICIAL FOR ANY ADDITIONAL REQUIREMENTS HEATING AND COOLING SYSTEM. N/A - NEW BUILDING NOT 420 SPECIFIC TO JURISDICTION AND SITE. HEATED OR COOLED (PROTECT EXISTING DUCT OPENINGS 1/8" DIA 120 ETC. AT ADJACENTS AREAS DURING CONSTRUCTION. STEEL r Mastic texture coatingis 5 504 4- FINISH WITH STRAW BALES STAPLES 2 PER BALE 10 MIL PLASTIC BINDING WIRE LINING NATIVE MATERIAL (OPTIONAU STRAW BALE WOOD OR METAL SECTION B-13 NOTES: (2 PER BALE) NOTES: NOT TO SCALE I: ACTUAL LAYOUT TO BE DETERMINED IN FIELD. 2. THE CONCRETE WASHOUT SIGN SHALL BE INSTALLED WITHIN 30 FT. OF THE TEMPORARY CONCRETE WASHOUT FACILITY. m i( \ PERMIT# --- BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR CTE COMPLIANCE PATE 5.504.5.3 MECHANICAL VENTILATION MUST HAVE MERV 8 FILTERS. N/A - BUILDING NOT HEATED OR COOLED 5.504.1 IF OUTDOOR SMOKING AREAS ARE PROVIDED THEY MUST MUST BE GREATER THAN 25' AWAY FROM ALL BUILDING OPENINGS. 5.506.1 OUTSIDE AIR DELIVERY FOR MECHANICALLY OR NATURALLY VENTILATED SPACES IN BUILDINGS, MEET THE MINIMUM REQUIREMENTS OF SECTION 120.1 OF THE CALIFORNIA ENERGY CODE AND CHAPTER 4 OF CCR, TITLE 8 OR THE APPLICABLE LOCAL CODE, WHICHEVER IS MORE STRINGENT. 5.508.1 HVAC AND FIRE SUPPRESSION SYSTEMS SHALL NOT CONTAIN CHLOROFLUOROCARBONS OR HALONS. N/A - NOT HVAC SYSTEM OR FIRE SUPPRESSION SYSTEM. TABLE 5.504.4.5 TABLE 5.504.4.1 VOC, CONTENT LIMITS FOR ARCHITECTURAL GOATIN652 5 ADHESIVE VO0 LIMIT I, 2 Grams of VOC per Liter of coating, Less Water and Less Exempt Compounds In Grams per Liter Less Water and Less Exempt Compounds In Grams per Liter COATING CATEGORY EFFECTIVE PLAN STRAW BALE (TYPICAL) WIRENC r 100 Nonflat-hi h gloss coatings 150 UDING ADHESIVES, SEALANTS 504.4.6.1 CAULKS, PAINTS, COATINGS, CARPETS, CARPET PADS, AND COMPOSITION WOOD PRODUCTS MUST MEET APPROPRIATE LOW VOC REQUIREMENTS AND 0.11 Aluminum roof coatings NOT TO SCALE TYPE "ABOVE GRADE" Basementspecialty coatings STAPLE DETAIL Bituminous roof coatings 50 CERTIFICATIONS. DOCUMENTATION MUST BE PROVIDED TO SHOW COMPLIANCE. REFER TO SHEET A-1 FOR VOC AND FORMALDEHYDE LIMIT TABLES. WITH STRAW BALES STAPLES 2 PER BALE 10 MIL PLASTIC BINDING WIRE LINING NATIVE MATERIAL (OPTIONAU STRAW BALE WOOD OR METAL SECTION B-13 NOTES: (2 PER BALE) NOTES: NOT TO SCALE I: ACTUAL LAYOUT TO BE DETERMINED IN FIELD. 2. THE CONCRETE WASHOUT SIGN SHALL BE INSTALLED WITHIN 30 FT. OF THE TEMPORARY CONCRETE WASHOUT FACILITY. m i( \ PERMIT# --- BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR CTE COMPLIANCE PATE 5.504.5.3 MECHANICAL VENTILATION MUST HAVE MERV 8 FILTERS. N/A - BUILDING NOT HEATED OR COOLED 5.504.1 IF OUTDOOR SMOKING AREAS ARE PROVIDED THEY MUST MUST BE GREATER THAN 25' AWAY FROM ALL BUILDING OPENINGS. 5.506.1 OUTSIDE AIR DELIVERY FOR MECHANICALLY OR NATURALLY VENTILATED SPACES IN BUILDINGS, MEET THE MINIMUM REQUIREMENTS OF SECTION 120.1 OF THE CALIFORNIA ENERGY CODE AND CHAPTER 4 OF CCR, TITLE 8 OR THE APPLICABLE LOCAL CODE, WHICHEVER IS MORE STRINGENT. 5.508.1 HVAC AND FIRE SUPPRESSION SYSTEMS SHALL NOT CONTAIN CHLOROFLUOROCARBONS OR HALONS. N/A - NOT HVAC SYSTEM OR FIRE SUPPRESSION SYSTEM. TABLE 5.504.4.5 TABLE 5.504.4.1 VOC, CONTENT LIMITS FOR ARCHITECTURAL GOATIN652 5 ADHESIVE VO0 LIMIT I, 2 Grams of VOC per Liter of coating, Less Water and Less Exempt Compounds In Grams per Liter Less Water and Less Exempt Compounds In Grams per Liter COATING CATEGORY EFFECTIVE Flat coatings 50 Nonflat Coatings 100 Nonflat-hi h gloss coatings 150 5perlall;9 coatings 0.11 Aluminum roof coatings 400 Basementspecialty coatings 400 Bituminous roof coatings 50 Bituminous roof primers 550 Bond breakers 350 Concrete curing compounds 550 corcrete/mosonrq sealers 100 Driveway sealers 50 Vrq fog coatings 150 Faux finishing coatings 550 Fire resistive coatings. 550 Floor coatings 100 Form -release compounds 250 Graphic arts coatings (signpoints) 500 High temperature coatings 420 Industrial maintenance coatings 250 Low solids coatin s l 120 Ma nesite cement coatin s 450 Mastic texture coatingis 100 Metallic pigmented coatings 500 Multicolor coatings 250 Pretreatment wash primers 420 Primers, sealers, and undercoaters 100 Reactive penetrating sealers 550 Req cled coatings 250 Roof coatings 50 Rust preventative coatings 250 Shellacs - Clear - Opaque -150 550 Specialty rimers, sealers, and undercoaters 100 Stains 250 Stone consolidates 450 Swimming pool coatin s 540 Traffic marking coatings 100 Tub and tile. refinish coatings 420 Waterproof Ing membranes 250 Wood coatings 215 Wood preservatives 550 Zinc -rich primers 540 I. Grams of VOC per -liter of coating, Including water and Including exempt compounds. 2. The specified limits remain In effect unless revised limits are listed In subsequent columns In the table 3. Values In this table are derived from those specified by the California Air Resources Board, Architectural Coatings Suggested Control Measure, February I, 2008. More Information Is .available from the Air Resources Board TABLE 5.504.4.5 FORMALDEHYDE LIMIT51 Maximum Formaldehyde Emissions In Parts per Million PRODUCT CURRENT LIMIT Hardwood plywood veneer core 0.05 Hardwood plywood composite core 0.05 Particleboard 0.09 Medium clensltv fiberboard 0.11 Thin medium density fiberboard 2 0.15 I. Values In this table are derived from those specified by the California Air Resources Board, Air Toxics Control Measure for Composite Wood as tested In accordance with A5TM E 1535. For additional Information, see California Code of Regulotons, Title 11, Sections 95120 through 95120.12. 2. This medium density fiberboard has a maximum thickness of 5/16" 68 mm). ARCHITECTURAL APPLICATIONS CURRENT VOC LIMIT Indoor carpet adhesives 50 Carpet pad adhesives 50 Outdoor car et adhesives 150 Wood Flooring adhesives 100 Rubber floor adhesives 60 5ubfloor adhesives 50 Ceramic tile adhesives 65 VCT and asphalt tile adhesives 50 Drywall and ponel adhesives 50 Cove base adhesives 50 Multi ur ose construction adhesives '10 Structural glazing adhesives 100 Single-l51ngle-plg roof membrane adhesives 250 Other adhesives not ecificall listed 50 SPECIALTY APPLICATIONS PVC weldin 510 cPVC weldin 490 A55 "aiding525 Plastic cement Holding 250 Adhesive primer for plastic 550 Contact adhesive 80 Special purpose contact adhesive 250 Structural wood member adhesive 140 Top and trim adhesive 250 SUBSTRATE SPECIFIC APPLICATIONS Metal to metal 50 Plastic foams 50 Porous material (except wood) 50 Wood Flooring adhesive 50 Fiberglass 60 I. If an adhesive Is used to bond dissimllor substrates together, the adhesive with the highest VOC, content shall be allowed. 2. For additional information regarding methods to measure the VOC content specifled In this table, see TABLE 5.504.4.2 SEALANT V00 LIMIT Less Water and Less Exempt Compounds in Grams per Liter SEALANTS CURRENT VOO LIMIT Architectural 250 Marine deck "160 Nonmembrone roof 500 Roadway 250 51n le- roof membrane 450 Other 420 SEALANT PRIMERS Architectural - Nonpourous - Pourous 250 '1'15 Plastic cement welding 500 Adhesive primer for pla5tic, 160 Contact adhesive T50 REVIEWED FOR CODE COMPLIANCE NOV 10 2015 INTERWEST CONSULTING GROUP Revisions: 10/24/2016 PLAN CHECK I 'lot Date: 10/24/20161 1� Date: 10-2016 Drawn: GC Job No: 15-051 Sheet: A07 of: f 1 - _ I J1 111,1111 V � O U � ,O N O 1V1 U a NN U a M � pp�L L V 11 J -L-1 � _u pQ �2J m `n I w v Q) � m in N f�r W U V U QR� 4 o �l M U 1� Date: 10-2016 Drawn: GC Job No: 15-051 Sheet: A07 of: f 1 - _ I J1 111,1111 V ,O V u 1V1 m� 1-I--1 �X- � pp�L L V 11 J -L-1 _u m 1� Date: 10-2016 Drawn: GC Job No: 15-051 Sheet: A07 of: f 1 - _ I J1 111,1111 13 REFER TO ACCESSIBLE SIGNAGE AC -1 NOTES DETAIL FOR MOUNTING _ _ TACTILE EXIT SIGNAGE NOTES: HEIGHT, LOCATION, CHARACTER 45°_Q SIZING, ETC.,. TACTILE EXIT SIGNS ARE REQUIRED PER 2013 C.B.C. 1011.9 - AT THE FOLLOWING LOCATIONS: CHARACTERS --}- 1. EACH GRADE -LEVEL EXTERIOR EXIT DOOR SHALL BE IDENTIFIED BY A ROOM TACTILE TACTILE EXIT WITH THE WORD "EXIT" TITLE 51GN 18" 2. EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE -LEVEL EXTERIOR EXIT BY MEANS OF A STAIRWAY OR RAMP SHALL BE IDENTIFIED BY A LL CLEAR FLOOR TACTILE EXIT SIGN WITH THE FOLLOWING WORDS AS APPROPRIATE: q SPACE AT 2.1 "EXIT STAIR DOWN" /NOTE 3 x TACTILE SIGN 2,2 "EXIT RAMP DOWN" CORRESPONDING 703.9.2 2,3 'EXIT STAIR UP" BRAILLE, LEFT 2,4 "EXIT RAMP UP OR CENTER p JUSTIFIED 3. ' EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE -LEVEL EXTERIOR EXIT BY MEANS OF AN EXIT ENCLOSURE OR AN EXIT EXIT PASSAGEWAY SHALL BE IDENTIFIED BY A EXIT SIGN WITH THE WORDS ".EXIT ROUTE". 4. EACH EXIT ACCESS DOOR FROM AN INTERIOR ROOM OR AREA TO A SINGLE DOOR + " G MOUNT SIGN AT 98 MIN. TO BASELINE OF CORRIDOR OR HALLWAY THAT IS REQUIRED TO HAVE VISUAL EXIT SIGN LOWEST BRAILLE OR +60" MAX. FROM SHALL BE INDENTIFIED BY THE TACTILE EXIT SIGN WITH THE WORDS BASELINE OF HIGHEST LINE OF RAISED TEXT. "EXIT ROUTE". NOTES: S. EACH EXIT DOOR THROUGH A HORIZONTAL EXIT SHALL BE IDENTIFIED 1. SIGN SHALL BE LOCATED ALONGSIDE BY A SIGN WITH THE WORDS "TO EXIT DOOR AT LATCH SIDE. WHERE TACTILE WITH 2 ACTIVEN 15 DED AT LEEAFS, SIGN I DOUBLE LOBE ` No WITH LOCATED TO THE RIGHTOFTHE RIGHT HAND DOOR. AT DOUBLE DOORS WITH 180/DOOR ONE ACTIVE LEAF THE SIGN SHALL BE SWING LOCATED ON THE INACTIVE LEAF. \ I 2. WHERE THERE IS NO WALL SPACE AT THE LATCH SIDE OF A SINGLE DOOR OR AT RIGHT \ I SIDE OF DOUBLE DOORS, SIGNS SHALL BE \ LOCATED ON THE NEAREST ADJACENT WALL. \ I 3. SIGNS CONTAINING TACTILE CHARACTERS \ SHALL BE LOCATED 50 THAT A CLEAR FLOOR SPACE OF 18" MIN x 18" MIN, 15 CENTERED ON THE TACTILE CHARACTERS, NOTE: SEE DETAIL AC -I FOR SIGNAGE LOCATION. 15 PROVIDED DOUBLET DOOR DOOR SWUNG BETWEEDN THE CLOSED THE ARC OF ANY POSITION AND 450 OPEN POSITION. 15 PERMANENT DOOR SIGNAGE 12 TACTILE EXIT SIGNAGE NOTES AC -1 REV: 02-18-2014 CBC 2013 IIB -103.4 SCALE: N/A AC-) 2013 CBC 1011A SCALE: N/A FINISH AND CONTRAST: CHARACTERS, SYMBOLS AND THEIR BACKGROUND SHALL HAVE A NON- GLARE FINISH. CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND, EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND. CASE: CHARACTERS SHALL BE UPPERCASE OR LOWERCASE OR A COMBINATION OF BOTH. STYLE: CHARACTERS SHALL BE CONVENTIONAL IN FORM. CHARACTERS SHALL NOT BE ITALIC, OBLIQUE, SCRIPT, HIGHLY DECORATIVE, OR OF OTHER UNUSUAL FORMS, MINI HORIZONTAL 1132" CLR. MIN. FOLDING DOOR THRESHOLD ACCESSIBLE THRESHOLD _� M w 3. OPERABLE PARTS SHALL BE OPERABLE =o CHARACTERS SHALL BE SELECTED FROM FONTS WHERE THE WIDTH OF THE LANDING TO BE FLUSH WITH FINISH BUMPER IN POCKET OOR TO PREVENT DOOR CHARACTER FLOOR AT DOOR IFCONCRETE PROVIDE ROM FULLY RECEDING UPPERCASE LETTER "0" 1560 PERCENT MINIMUM AND 110 PERCENT MAXIMUM "I". V, r_ 1111111111", 112 N GUIDE RAIL o x>� �Lu� COMPRESSED CARPET 12" AND GREATER TIGHT GRASPING, PINCHING, OR TWISTING OF THE HEIGHT OF THE UPPERCASE LETTER z ., ; 114" MAX. BELOW LESS THAN 180" CLR. MIN. CHARACTER HEIGHT: ui o32" o Zo 24" MIN. '. SLIDING DOOR THRESHOLD Z WHEN DOOR E L ACTIVATE OPERABLE PARTS SHALL BE L VER PUSH/PUL PANIC BARS 5 LBS MAXIMUM. MINIMUM CHARACTER HEIGHT SHALL COMPLY WITH TABLE IIB -103.5.5. z- 'ySWINGS ONTO = r- - - - - - - - - - - - - THAN 120" w� X LANDING. I 60" x 60" MIN. CLEAR VIEWING DISTANCE SHALL BE MEASURED AS THE HORIZONTAL DISTANCE > 4" F I DOOR MUST OPEN I BETWEEN THE CHARACTER AND AN OBSTRUCTION PREVENTING FURTHER 900 MINIMUM. FINISH FLOOR LEVEL � ILu L CROSS HARDWARE MOUNTING HEIGHTS OPENABLE FROM THE EGRESS SIDE APPROACH TOWARDS THE SIGN. CHARACTER HEIGHT SHALL BE BASED cr)0 6„ m N< SLOPE ^ DOOR HEIGHT: ------------------ o zo p 6'-8" MIN. CLEAR I ON THE UPPERCASE LETTER "1" NP N - DOOR CLOSERS AND I PROVIDE 18" MINIMUM STOPS SHALL BE 1 AT INTERIOR DOORS, PERMITTED TO BE AND 24" MINIMUM AT 18" MIN. A.F.F. i EXTERIOR DOORS IF X IS GREATER THAN 8" 32" MINIMUM NOTE: REQUIRED LANDING DIMENSIONS SHOWN ARE TYPICALI CLEAR WIDTH AND MAY CHANGE BASED ON DIRECTION OF APPROACH AND 1 DOOR HARDWARE. REFER TO LEVEL "MANEUVERING CLEARANCES 11 90°-0' AT DOORS" DETAIL FOR MORE INFORMATION, AND TO FLOOR/SITE is PLAN FOR SITE SPECIFIC DESIGN. - - - - - - - - X � a �p 36" MIN. CLEAR OPENING IF MORE THAN 24" DEEP HINGED DOOR 06 TYPICAL ACCESSIBLE DOOR LANDING 03 DOOR CLEAR OPENING REQUIREMENTS AC -I SCALE: NONE AC -I SCALE: NONE DOOR HARDWARE NOTES: I. DOOR CLOSERS AND GATE CLOSERS SHALL BE ADJUSTED SO THAT FROM AN CENTERLINE DOOR OPEN POSITION OF 90 DEGREES, THE HARDWARE TIME REQUIRED TO MOVE THE DOOR TO A POSITION OF 12 DEGREES FROM THE LATCH 15 5 SECONDS MINIMUM. 2. DOOR AND GATE SPRING HINGES SHALL USO POSIIADJUSTED 0 F10 DEGREES,OTHE THE - - ION OR GATE SHALL MOVE TO THE CLOSED r Z POSITION IN 15 SECONDS UM PROPORTIONS: HORIZONTAL _ 5., °° � Lu v " DESIGN THRESHOLD VIEWING _� M w 3. OPERABLE PARTS SHALL BE OPERABLE =o CHARACTERS SHALL BE SELECTED FROM FONTS WHERE THE WIDTH OF THE DISTANCE WHEEL wwLL TO SUIT CHARACTER 1,AC-1 (REV: 05-21-2015) (CBC 2013 CHAPTER IIB) SCALE: NONE o� WITH ONE HAND AND SHALL NOT REQUIRE UPPERCASE LETTER "0" 1560 PERCENT MINIMUM AND 110 PERCENT MAXIMUM "I". LESS THAN 12" GUIDE RAIL o x>� �Lu� COMPRESSED CARPET 12" AND GREATER TIGHT GRASPING, PINCHING, OR TWISTING OF THE HEIGHT OF THE UPPERCASE LETTER z ., ; 114" MAX. BELOW LESS THAN 180" OF THE WRIST. THE FORCE REQUIRED TO CHARACTER HEIGHT: AND GREATER 2" MIN �z 4 MAX THRESHOLD FINISH FLOOR E L ACTIVATE OPERABLE PARTS SHALL BE L VER PUSH/PUL PANIC BARS 5 LBS MAXIMUM. MINIMUM CHARACTER HEIGHT SHALL COMPLY WITH TABLE IIB -103.5.5. LESS THAN 21" � CURB THAN 120" LEVELS EVEN 3" + 1/8" PER FOOT OF VIEWING DISTANCE SHALL BE MEASURED AS THE HORIZONTAL DISTANCE > 4" F I 4. EGRESS DOORS SHALL BE READILY BETWEEN THE CHARACTER AND AN OBSTRUCTION PREVENTING FURTHER 48"MINIMUM CLEAR FINISH FLOOR LEVEL HARDWARE MOUNTING HEIGHTS OPENABLE FROM THE EGRESS SIDE APPROACH TOWARDS THE SIGN. CHARACTER HEIGHT SHALL BE BASED PATH OF TRAVEL ------------------ WITHOUT THE USE OF A KEY OR SPECIAL ON THE UPPERCASE LETTER "1" (2013 CBC IIB -409.2.1) KNOWLEDGE OR EFFORT, HEIGHT TO FINISH HORIZONTAL MINIMUM CHARACTER HEIGHT FLOOR OR GROUND VIEWING 10 AC -1 FROM BASELINE OF DISTANCE AC -I (REV: 11-20-2015) (CBC 2013 CHAPTER JIB) SCALE: NONE CHARACTER 1,AC-1 (REV: 05-21-2015) (CBC 2013 CHAPTER IIB) SCALE: NONE `O\ V 40" TO LESS LESS THAN 12" 5/81, THAN EQUAL TO l0"" 12" AND GREATER 5/8" + 1/8" PER FOOT OF z VIEWING DISTANCE ABOVE 12" GREATER THAN 10" LESS THAN 180" 2" TO LESS THAN OR180" OR EQUAL TO 1200"" AND GREATER 2" + 1/8" PER FOOT OF VIEWING DISTANCE ABOVE 180" GREATER LESS THAN 21" 3" THAN 120" 21' AND GREATER 3" + 1/8" PER FOOT OF VIEWING DISTANCE ABOVE 21' S. THE UNLATCHING OF ANY DOOR OR LEAF WHEEL GUIDE RAIL GUIDE/WARNING CURB SHALL NOT REQUIRE MORE THAN ONE A WHEEL GUIDE RAIL SHALL - OR - PROVIDE 2" MINIMUM HIGH OPERATION. BE PROVIDED, CENTERED 2" GUIDE CURB. MINIMUM AND 4" MAXIMUM ABOVE XI 6. THE FORCE FOR PUSHING OR PULLING THE WALKING SURFACE. NOTES 1. ABRUPT CHANGES IN LEVEL EXCEEDING 4" IN A VERTICAL DIMENSION BETWEEN WALKS, SIDEWALKS, OR OTHER PEDESTRIAN WAYS AND ADJACENT SURFACES OR FEATURES SHALL BE IDENTIFIED BY WARNING CURBS AT LEAST 0 IN HEIGHT ABOVE THE WALK OR SIDEWALK SURFACE, OR BY A GUARD OR HANDRAIL EQUIPPED WITH A WHEEL GUIDE RAIL. 2. A CURB, 2" HIGH MINIMUM, OR BARRIER SHALL BE PROVIDED THAT RAISED CHARACTERS AND PICTORIAL SYMOBL SIGNS: PREVENTS THE PASSAGE OF A 4" DIAMETER SPHERE, WHERE ANY PORTION OF THE SPHERE 15 WITHIN 9" OF THE FINISH FLOOR OR GROUND SURFACE. WHEN RAISED CHARACTERS ARE REQUIRED OR WHEN PICTORIAL SYMBOLS (PICTOGRAMS) ARE USED ON SUCH SIGNS, THEY SHALL CONFORM TO THE 3. TO PREVENT WHEEL ENTRAPMENT, THE CURB OR BARRIER SHALL PROVIDE. FOLLOWING REQUIREMENTS A CONTINUOUS AN UNINTERRUPTED BARRIER ALONG THE FULL LENGTH Of CHARACTER TYPE: THE WALKING SURFACE. L CHARACTERS ON SIGNS SHALL BE RAISED 1/32 INCH MINIMUM AND SHALL BE SANS SERIF UPPERCASE CHARACTERS ACCOMPANIED BY CONTRACTED (GRADE D BRAILLE COMPLYING WITH SECTIONS II13-103.3 AND II13-103.4 II CHARACTER SIZE: O8 EDGE PROTECTION ,AT WALKWAY 05 DOOR THRESHOLD 2. RAISED CHARACTERS SHALL BE A MINIMUM OF 5/8 INCH AND A MINIMUM OF 2 INCHES HIGH. AC -1 AC -1 2013 CBC IIB -303 SCALE: N/A AC -1 PICTORIAL SYMBOL SIGNS (PICTOGRAMS): 3. PICTORIAL SYMBOLS SIGNS (PICTOGRAMS) SHALL BE ACCOMPANIED BY 013.2 GUARDS SHALL BE LOCATED ALONG OPENSIDED WALKING SURFACES, INCLUDING THE VERBAL DESCRIPTION PLACED DIRECTLY BELOW THE PICTOGRAM. MEZZANINES EQUIPMENT PLATFORMS, STAIRS, RAMPS AND LANDINGS THAT ARE THE OUTSIDE DIMENSION OF THE PICTOGRAM FIELD SHALL BE A MINIMUM LOCATED MORE THAN 30 INCHES MEASURED VERTICALLY TO THE FLOOR OR INDCATS AREA OF 6 INCHES IN HEIGHT. GRADE BELOW AT ANY POINT WITHIN 36 INCHES HORIZONTALLY TO THE EDGE OF CHARACTER PLACEMENT: THE OPEN SIDE. GUARDS SHALL BE ADEQUATE IN STRENGTH AND ATTACHMENT 4 CHARACTERS AND BRAILLE SHALL BE IN A HORIZONTAL FORMAT IN ACCORDANCE WITH SECTION 1601.8. r- ---- -- ------ OPEN A DOOR OR GATE OTHER THAN GLASS OR A FIRE DOOR SHALL NOT EXCEED 5 PANEL �� POUNDS (22.2N). 10" MIN. BOTTOM RAIL DOOR KICK PLATE (2013 CBC II13-404.2.10) I. THE BOTTOM 10" OF ALL DOORS, EXCEPT SLIDING DOORS, SHALL HAVE A SMOOTH SURFACE ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE DOOR OR GATE. KICKPLATES SHALL BE FREE OF SHARP OR ABRASIVE EDGES. CAVITIES CREATED BY ADDED KICK PLATES SHALL BE CAPPED. 02 DOOR HARDWARE / KICKPLATE SCALE: NONE �AC-jj 2013 CBC CHAPTER IIB SCALE: NONE BRAILLE SHALL BE PLACED A MINIMUM OF 3/8 INCH AND A MAXIMUM OF EXCEPTION: GUARDS ARE NOT REQUIRED FOR THE FOLLOW LOCATIONS: PULL 51DE I 2 DIRECTLY BELOW THE ARA ERS FLUSH LEFT OR r C INCH C Y ECHARACTERS; 1. ON THE LOADING SIDE OF DOCKS OR PIERS. APPROACH CENTERED. WHEN TACTILE TEXT 15 MULTILINED; ALL BRAILLE SHALL BE PLACED TOGEHER BELOW ALL LINES OF TACTILE TEXT. 2. ON THE AUDIENCE SIDE OF STAGES AND RAISED PLATFORMS, INCLUDING' -i STEPS LEADING UP TO THE STAGE AND RAISED PLATFORMS. PROPORTIONS: � ::29" .MIN. CLEAR AT . O E i 5. RAISED CHARACTERS ON SIGNS SHALL BE SELECTED FROM FONTS 3 N RAISED STAGE AND PLATFORM AREAS, SUCH AS RUNWAYS, RAMPS AND EXTERIOR SIDE OF WHERE THE WIDTH OF THE UPPERCASE LETTER "0" 15 60 PERCENT SIDE STAGES USED FOR ENTERTAINMENT OR PRESENTATIONS. EXTERIOR DOOR MINIMUM AND 110 PERCENT MAXIMUM OF THE HEIGHT OF THE UPPERCASE 4. AT VERTICAL OPENINGS IN THE PERFORMANCE AREA OF STAGES AND PULL SIDE � LETTER "I". STROKE THICKNESS OF THE UPPERCASE LETTER T' SHALL PLATFORMS. ' i i APPROACH BE IS PERCENT MAXIMUM OF THE HEIGHT OF THE CHARACTER. S. AT ELEVATED WALKING SURFACES APPURTENANT TO STAGES AND BRAILLE: PLATFORMS FOR ACCESS TO AND UTILIZATION OF SPECIAL LIGHTING OR o 18" CLR MIN. AT i p 36" CLR. MIN. i o EQUIPMENT. �° -' INTERIOR DOORSr PULL SIDE �^' 24" MIN. CONTRACTED (GRADE 2) BRAILLE SHALL BE USED WHEREVER BRAILLE 15 APPROACH REQUIRED IN OTHER PORTIONS OF THESE STANDARDS. DOTS SHALL BE 1/10 6. ALONG VEHICLE SERVICE PITS NOT ACCESSIBLE TO THE PUBLIC. INCH ON CENTER IN EACH CELL WITH 2/10 INCH SPACE BETWEEN CELLS 1. IN ASSEMBLY SEATING WHERE GUARDS IN ACCORDANCE WITH SECTION MEASURED FROM THE SECOND COLUMN OF DOTS IN THE FIRST CELL TO THE 1028A ARE PERMITTED AND PROVIDED. FIRST COLUMN OF DOTS IN THE SECOND CELL. DOTS SHALL BE RAISED A MINIMUM OF 1/40 INCH ABOVE THE BACKGROUND. BRAILLE DOTSSHALL BE 1013.2.1 WHERE GLASS I$ USED TO PROVIDE A GUARD OR AS A PORTION OF THE GUARD ' DOMED OR ROUNDED. SYSTEM, THE GUARD SHALL ALSO COMPLY WITH SECTION 2401. WHERE THE GLAZING PROVIDED DOES NOT MEET THE STRENGTH AND ATTACHMENT MOUNTING LOCATION AND HEIGHT: REQUIREMENTS OF SECTION 1601.8, COMPLYING GUARDS SHALL ALSO BE LOCATED ALONG GLAZED SIDES OF OPEN -SIDED WALKING SURFACES. PROVIDE THIS ADDITIONAL WHERE A TACTILE SIGN IS PROVIDED AT A DOOR THE SIGN SHALL BE SPACE IF DOOR 15 LOCATED ALONGSIDE THE DOOR AT THE LATCH SIDE. WHERE A TACTILE SIGN 1013.3 REQUIRED GUARDS SHALL NOT BE LESS THAN 42 INCHES HIGH, MEASURED RUIPPED WITH BOTH A = IS PROVIDED AT DOUBLE DOORS WITH ONE ACTIVE LEAF, THE SIGN SHALL BE VERTICALLY AS FOLLOW: LATCH AND A CLOSER ��� 24" MIN. z i z oaW i 22" MIN LOCATED ON THE INACTIVE LEAF. WHERE A TACTILE SIGN 15 PROVIDED AT L FROM THE ADJACENT WALKING SURFACES; DOUBLE DOORS WITH TWO ACTIVE LEAFS, THE SIGN SHALL BE LOCATED TO 12" MIN opo i oo THE RIGHT OF THE RIGHT HAND DOOR. WHERE THERE IS NO WALL SPACE AT 2. ON STAIRS, FROM THE LINE CONNECTING THE LEADING EDGES OF THE TREAD d d NOSINGS: AND =o i i LLu THE LATCH SIDE OF A SINGLE DOOR OR AT THE RIGHT SIDE OF DOUBLE u U zea z DOORS, SIGNS SHALL BE LOCATED ON THE NEAREST ADJACENT WALL. 3. ON RAMPS, FROM THE RAMP SURFACE AT THE GUARD. zo '} I P =oom I PUSH SIDE =a PUSH SIDE �. i I PQa I APPROACH -'APPROACH SIGNS CONTAINING TACTILE CHARACTERS SHALL BE LOCATED 50 THAT A 1013.4 REQUIRED GUARDS SHALL NOT HAVE OPENINGS WHICH ALLOW PASSAGE OF A CLEAR FLOOR SPACE OF 18 INCHES MNIMUM BY I8 INCHES MINIMUM: CENTERED SPHERE 4 INCHES IN DIAMETER FROM THE WALKING SURFACE TO THE REQUIRED PUSH SIDE = r ������iVED ON THE TACTILE CHARACTERS, 15 PROVIDED BEYOND THE ARC OF ANY GUARD HEIGHT. APPROACH DOOR SWING BETWEEN THE CLOSED POSITION AND 45 DEGREE OPEN POSITION. EXCEPTIONS: L_- _____._____'_L____J FORCODECOMPLI NCE j"itMo WHERE PERMANENT IDENTIFICATION SIGNAGE 15 PROVIDED FOR ROOMS AND }C 4 - - SPACES THEY SHALL BE LOCATED ON THE APPROACH SIDE OF THE DOOR I. FROM A HEIGHT OF 36 INCHES TO 42 INCHES, GUARDS SHALL NOT HAVE 5 A1rTT=COUNTY DEVFlor)NA NITSCRVtcE4 AS ONE ENTERS THE ROOM OR SPACE. SIGNS THAT IDENTIFY EXITS SHALL BE OPENINGS WHICH ALLOW PASSAGE OF A SPHERE 4 3/8 INCHES IN DIAMETER REVIEWED FOR LOCATED ON THE APPROACH SIDE OF THE DOOR AS ONE EXITS THE ROOM 2. THE TRIANGULAR OPENINGS AT THE OPEN SIDES OF A STAIR, FORMED BY CODE COMPLIANCE OR SPACE. THE RISER, TREAD AND BOTTOM RAIL SHALL NOT ALLOW PASSAGE OFA rr ( ' n SIGNS WITH RAISED CHARACTERS AND BRAILLE SHALL BE LOCATED 48" MIN. SPHERE 6 INCHES IN DIAMETER. INTERWEST DATE. b` - -- BY `ti/U� _ ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE BASE 3. AT ELEVATED WALKING SURFACES FOR ACCESS TO AND USE OF ELECTRICAL, CONSIJI-TINr- C-pn'!o LINE OF THE LOWEST LINE OF BRAILLE AND 60" MAXIMUM ABOVE THE FINISH MECHANICAL, OR PLUMBING SYSTEMS OR EQUIPMENT, GUARDS SHALL NOT FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE HIGHEST HAVE OPENINGS WHICH ALLOW PASSAGE OF A SPHERE 21 INCHES IN DIAMETER. FRONT APPROACH HINGE APPROACH LATCH APPROACH LINE OF RAISED CHARACTERS. 13 ACCESSIBLE SIGNAGE NOTES 10 AC -1 Ol GUARDS 04 LEVEL MANEUVERING CLEARANCE AT DOORS AC -I (REV: 11-20-2015) (CBC 2013 CHAPTER JIB) SCALE: NONE AC -1 2013 CBC 1013 SCALE: N/A 1,AC-1 (REV: 05-21-2015) (CBC 2013 CHAPTER IIB) SCALE: NONE _ III1 IF' r I Revisions: Plot Date: 10/24/2016 o in o p N O 6 NP7U.. 0) m W W U oo= RE mm� a Q rn W r - v cn w in N W U Q 0 U Date: 8-2016 Drawn: GC Job No: 15-051 Sheet: Qct ot: I III VIII '. III �NI�� v `O\ V t1 >/ �mm z 4J --I z 7- 7 Z � m Date: 8-2016 Drawn: GC Job No: 15-051 Sheet: Qct ot: I III VIII '. III �NI�� s IL LL 014100 DESIGN DATA Code used: 2013 California Building Code Floor loading: N/A - Slab on grade Roof loading: See metal building package Wind loading: See metal building package Seismic: See metal building package 014100 FOUNDATION DESIGN DATA 1. Soil design information: Allowable soil design pressures: Continuous footings 1500 PSF Grade beams 1500 PSF Isolated footings 1500 PSF Retaining walls: Active pressure (restrained) 60 PCF Active pressure (cantilevered) 35 PCF Passive pressure 150 PCF Frictional resistance 0.25 x dead load 2. Minimum footing depth: Bottom of footings shall be located at 12" below top of adjacent natural grade - see Drawings. 01 41 13 GENERAL CONDITIONS 1. All work on this project shall conform to the adopted editions of the UBC, UMC, NEC and any other applicable County and/or City codes and ordinances. 2013 CBC (Based on 2012 IBC), 2013 CRC (Based on 2012 IRC), 2013 CMC (Based on 2012 UMC), 2013 CPC (Based on 2012 UPC), 2013 CEC (Based on 2011 NEC), 2013 CFC (Based on 2012 IFC), 2013 California Green Building Standards Code, and the 2013 Building Energy Efficiency Standards. 2. Architect shall approve all adjustments to these plans related to the Drawings. 3. Written dimensions are to be used; do not scale these drawings. 4. Specific information on the Drawings differing from these notes shall apply. 5. The Contractor shall verify site conditions, and their correlation with the Drawings, and shall notify the Architect in writing of any errors, inconsistencies, omissions or discrepancies prior to beginning of construction. The Contractor shall be held liable for the results of any known errors, inconsistencies, discrepancies or omissions that are not brought to the Architect's attention prior to commencement of work. 6. In the event certain features of the construction are not fully shown on the Drawings or called for the Specifications then their construction shall be of the same character as for similar conditions that are shown or called for and shall be approved by the Architect. 7. The Drawings represent the finished structure. Unless otherwise indicated, they do not indicate the method of construction. The Contractor shall provide all measures necessary to protect the structure, workmen and other persons during construction. Such measures shall include, but not be limited to; bracing, shoring for construction equipment, shoring for the building, forms, and scaffolding. 8. All site -work and grading shall be done in compliance with the Drawings. Where shown on Drawings, elevations, and locations of steps in foundation, and heights of foundation walls shall be verified to suit actual proposed and existing conditions. 9. Finish grade and finish floor elevations to be per site plan. 10. Dimensions noted "clear" or "cir" are minimum required dimensions and must be accurately maintained. 11. All dimensions are to face of stud; face of concrete, or face of masonry, unless otherwise noted. 12. Construction shown on these drawings shall in no case deviate from the design shown without express written permission of the Architect and/or the local Building official 0145 33 SPECIAL INSPECTIONS 1. In addition to inspections required by CBC 1.8.4.4, the project owner or the Architect of record acting as the owner's agent shall employ one or more special inspectors who shall provide inspections during construction for the following items: a. Concrete - During the taking and testing of test specimens and placing of reinforced concrete. Exceptions: 1. Foundation concrete where the structural design is based on an Fc no greater than 2500 psi, regardless of the compressive strength specified in the construction documents or used in the footing construction CBC1704.4 (2.3). 2. Duties and responsibilities of the special inspector: a. The special inspector shall observe the work assigned for conformance with the approved design drawings and specifications. b. The special inspector shall furnish weekly inspection reports to the building official, the engineer or architect of record, and other designated persons. All discrepancies shall be brought to the immediate attention of the contractor for correction, then, if uncorrected, to the proper design authority and the Building Official c. The special inspector shall submit a final signed report stating whether the work requiring special inspection was, to the best of his knowledge, in conformance with the approved plans and specifications and the applicable workmanship provision of the CBC. d. Inspector shall maintain, on site, daily logs for review by the Jurisdiction inspectors. 3. A qualified person under contract with the project owner who is acceptable to the architect and Building Official shall provide the special inspections. Special inspections for this project are to be performed by: Applied Testing Consultants 3060 Thorntree Drive, Suite 10 Chico, California 95973 (530) 891-6625 4. A summary of tests, inspections and submittals performed by an approved special testing Jab, special inspector, architect, and/or engineer shall be as noted above, and specified in the matrix below. The special inspections listed are not intended to be all inclusive and only represent special inspection requirements for the structural portions of the work. Additional special inspections of architectural, mechanical, electrical, plumbing, fire sprinklers or other systems may be required. Refer to the appropriate design disciplines for additional information. Description Testing Special Structural Certificate Shop Inspection observation (Letter) drawings Concrete strength Yes 15-051 Concrete mix design Yes V J Epoxied anchors, Yes Expansion anchors, Post installed anchors 03 20 00 REINFORCING STEEL 1. Reinforcing steel to conform to ASTM A615, including supplement Sl. All bars shall be new stock deformed bars, grade 40 for #4 bars and smaller, grade 60 for #5 bars and larger, typical unless otherwise noted. Bars to be welded shall conform to ASTM 706. 2. Details for reinforcing shall conform to Chapter 7 of ACI 318-11. 3. Bar splices - Concrete - Unless noted otherwise, reinforcement bars to be lapped minimum 40 bar diameters, but in no case less than 24". Horizontal lops in adjacent bars shall be staggered 60" minimum. 4. Bends in reinforcement shall be in accordance with ACI 318-11. 5. Walls, pilasters and columns shall be doweled to their supporting footings with vertical dowels of the same size and spacing as the vertical reinforcing, unless otherwise noted on the plans. Where possible, vertical bars shall be one-piece, full height. 6. For concrete or masonry construction, vertical reinforcing bars shall be accurately located in walls as noted on plan details. 7. All reinforcing to be securely wired and properly supported above ground and away from the form. 8. Where required, bar supports shall be provided as specified in the "Manual of Standard Practice" published by the Concrete Reinforcing Steel Institute (CRSI). 9. All dimensions shown for locations of reinforcing steel are to center of bar unless noted as "cir". "Clr" dimensions are to face of bar and denote clear coverage. Unless specifically noted otherwise, concrete coverage shall be 3" where concrete is placed directly against earth, and 2" where concrete is exposed to earth but is against forms. Slabs on grade shall have reinforcing at mid -depth unless otherwise noted - refer to Drawing details. 10. Welding of crossing bars and tack welding of reinforcing shall not be permitted. 03 30 00 CAST -IN PLACE CONCRETE 1. Exposure class for concrete: Negligible exposure. 2. Construction joints shall be prepared to expose clean, solidly embedded aggregate over the entire joint interface. Construction joints shall be adequately keyed. Their locations and details, when not shown on the Drawings, shall be subject to the approval of the Architect. 3. Concrete placement shall be continuous between construction joints. 4. Unless otherwise shown on the drawings, concrete slabs shall be cast in square or rectangular patterns not exceeding 400 SF in area. Provide construction, contraction or weakened plane joints at intervals not exceeding 20 feet in any direction. Install contraction joints in both directions at re-entrant comers. 5. Sleeves, pipes and conduits shall not be placed through continuous or spread footings, grade beams or tie beams unless specified and detailed on plans. 6. Conduit shall not be placed in any slab less than 3-1/2 in. thick. If conduit is placed in a concrete slab, its outside diameter shall not be greater than 1/3 the slab thickness. The minimum clear distance between conduits shall be 6 inches. 7. All exposed corners shall be chamfered '/<in. unless noted otherwise. 8. Structural steel shapes, tubes and pipes embedded in concrete shall have a minimum concrete cover of 3 inches clear to earth. 9. Bottoms of all footings shall rest on firm, undisturbed soil. Minimum depth is noted on Drawings. 10. Concrete slabs on ground shall have a minimum thickness of 6". Refer to Drawings for more specific information. 11. Concrete slabs on ground required to have a vapor retarder by the California Building Code shall be underlain with the following assembly: A capillary break, consisting of a 4 -inch thick base of 1/2 inch or larger clean aggregate placed atop the sub grade, 10 mil vapor retarder, minimum 2" granular fill placed atop the vapor retarder. The granular fill atop the vapor retarder shall not be wet prior to placing concrete. 03 3100 STRUCTURAL CONCRETE 1. Foundation element or condition per CBC Table 1808.8.1: Foundations for Group R or U occupancy of light -frame construction, two stories or less in height, assigned to Seismic Design Category D, E, or F (2500psi). Foundations or other structures assigned to Seismic Design Category D, E or F (3000psi). Structural design is based on a compressive strength of 2500 psi. 2. The minimum 28 day compressive strength of concrete shall be: Foundations/pad footings 3000 PSI Slabs on grade 3000 PSI Walls and columns 3000 PSI 2. Concrete proportions shall be determined in accordance with the provisions of ACI 318, Section 5.2. 3. Concrete contractor shall submit a concrete mix design for concrete slabs on ground (prepared by the concrete supplier) to the Architect for review and approval prior to placing concrete. The mix design shall employ the use of optimal aggregate size to reduce the water/cement ratio. 4. Portland cement shall conform to ASTM C150. 5. Concrete aggregates shall conform to ASTM C33 for normal weight concrete. 6. Nominal maximum size of coarse aggregate shall not be larger than: a. 1/5 the narrowest dimension between sides of forms, nor; b. 1/3 the depth of slabs, nor; C. 3/4 the minimum clear spacing between individual reinforcing bars or wires. 7. Water used in mixing concrete shall conform to ASTM C1602. 8. Admixtures used to increase the workability of the concrete shall not be considered to reduce the specified minimum cement content. 9. Ready mix concrete shall be mixed and delivered in accordance with ASTM C-94. 05 00 00 STRUCTURAL STEEL NOTES 1. Materials and workmanship shall conform to the latest edition of the "Specification for the Design, Fabrication and Erection of Structural Steel for Buildings" published by the American Institute of Steel Construction (AISC). 2. Unless otherwise noted, machine bolts and anchor bolts shall conform to ASTM F1554, Grade 36. Hex nuts shall conform to ASTM A563A, Grade A. All threaded rods shall conform to ASTM A36, typical unless otherwise noted. 3. Miscellaneous metal components not noted shall conform to ASTM A36. /9 ! PERMIT# BUTTE COUNTY DEVELOPMENT SERVICES v �1 11 C REVIEWED FOR WED CODE COMPLIANCE FOR CODE COMPLIANCE DAM! t- k r A -t BY � 10 2016 INTECON ULTnWEGROUP REVISION DATE: 08-01-16 Revisions: .Nine 0 0_ IN ODS pp^r So IL W Ru�l V fr1 N M Q mU -.�cED.ARCN.. Date: 6-2016 Drawn: F.G. Job no.: 15-051 V J � � tfl z Q Z 11 Z L1 Q � m Date: 6-2016 Drawn: F.G. Job no.: 15-051 Sheet: S-1 L.1 Revisions: 10/24/2016 PLAN CHECK I Plot Date: 10/24/2016 REVIEWED i Date: 10-2016 FOR CODE COMPLIANCE Drawn: GC Nnv in mig Job No: 15-n51 u� w 0 N ❑ Q U Q Q ❑ / Q U USED Rc&l �G P�� Wkiy�Cr c� N I O ,r 0 N °° U V 0 ` P CAUF��\ Q � 1�1\\ V O in v UA LU a in rn U v 0 u �1 m U REVIEWED i Date: 10-2016 FOR CODE COMPLIANCE Drawn: GC Nnv in mig Job No: 15-n51 u� w 0 N ❑ Q U Q Q ❑ / Q U USED Rc&l �G P�� Wkiy�Cr c� ,r R ` P CAUF��\ 1�1\\ V O v UA LU z LL z F- UA ® N ' I ' 4N V <m REVIEWED i Date: 10-2016 FOR CODE COMPLIANCE Drawn: GC Nnv in mig Job No: 15-n51 u� w 0 N ❑ Q U Q Q ❑ / Q U MINIMUM BAR LAPS FOR REINFORCED STEEL CONCRETE STRENGTH: 3000 PSI OR LESS (STAGGER SPLICES) SIZE LAP LENGTH SIZE LAP LENGTH SIZE 'LAP LENGTH #3 14" #6 36" #9 80" #4 241, #'1 481, #10 101" #5 28" #8 63" #11 - 124" Revis 900 HOOK NOTE: / 1 1800 HOOK R=8 DIA.2 DIA. BOLTS SHALL BE INSTALLED TIGHT \ / OR TO REBAR HAIRPIN. 6" MIN, HAIRPINS MAY NOT BE FIELD BENT R cq t� O CONC. SLAB- SEE FOUNDATION PLAN CONC. SLAB - SEE FOUNDATION PLAN OD ®m L V 0 10 N 86 3 i7 k tp O OF to tt4 l2f� DOWELS M � aa 0 R=3 DIA.. FOR 43 TO ttTREINF. TYPICAL SLAB AT 32" 0, b DIA. OR 4" MIN.. R=4 DIA. FOR 98 TO ttll -SEE FOUND. PLAN U METAL BUILDING FRAME LINE LLI METAL BUILDING FRAME LINE I- STANDARD HOOKS AND BENDS ANCHOR BOLTS - HAIRPIN - SEE FOUNDATION PLAN AND ' 8" ul SEE FOUNDATION PLAN HAIRPIN REINF. SCHEDULE tt4 12 DOWELS 2 MIN. FOR STEPAT 32" O/C FOOTINGS f 1 t Yr tt4 DOWELS AT 48" O/C t EPDXY MIN. b" INTO (E) L 3 r'1i ' it "€ v'3 s PERIMETER FOOTING MINIMUM BAR SPACING (INCLUDING LAPS): 2" CLR OR 1-1/2 x BAR DIA: �I MAX.L il L5 x LAP EQUALS 150% LAP LENGTH REQUIRED 45° MAX. e/4"CLR + �' F tEi, i v t r div ! uv t :i r ! 1 , ,4rs,i3�'aa I"n vd, .., v13 3 .E r: ti. I Ir ".,I CONCRETE COVER FOR REINFORCING STEEL CLR L(� 3p " ' 3:.. ' ::E3::0 '.FNtriie ' ... _ .. :3 .iy b t.. is :i, h �.. FOR BEAMS AND nh VERT. tt5 BARS M k . �T . t d T.E :# !u 3 v... t 3Cn Y 1 C i. $ t { . t N AT 18" O/C 31 i 3v h: w�4irtlWflw+M�nW".... 4 s IE SLABS U.O.N. ( t .CAST AGAINST EARTH OR GRADE 3" +tp�E a 1 � +,ht ! iS ";1' a LI � .. � i'k it;� §i> €}ilk.:.riFt =y ��E 3. ed �:7ii -�t13 a$1 ims Lsa .y t : ,i d c r: ar�i i is• iii i„I : m€•,� 1 . ,:j. :.:; ( :.. �� �. :- .3:..:.. �,.: dii - 3E 3 i 3I r h S E .�,-vu I iiY. '< 4 COLUMN BAR OFFSET BENT BARS !' .IE � i 3>3 ri rEta. _ tLpi h`F! E,.. i, s'v r'. 3 EXPOSED TO EARTH. (FORMED) OR WEATHER - ,3nnn nn :dE`v 't „n: F.G. n _ • ._.",: i ., ._3.n nv§ nimv"LmnutE4:#:rLu my n. 1:.. rpy '!�, . E+ _ ,nnn:,l3 ..: ... ....,.t,... _... m � .. ..... �. �,o i.. a: �r. . u .+� � ,,,»+ >4':, . 1t r !•s,'i ;�a ._ 3Ev,' >`.,# b m OR 2 I/2 MIN.,.._":,_:m...3.....,.,:_.n.,..,nn:,n,..x..., ..:.E? .. di I , 3a ,Er3 :n ,k, n,. ,..H. �s3.:.�i tt5 AND SMALLER I I/2 - ...E . ,.....a... ..... m k .,..,„,..§ES ., n, F a .,....t i ..EF .$ i..,, i,• a4.... t< 3r.h :, 3,n8 ,:,:. , n.n9 t . IIII .3,Y4 n {, .l,..Ci..?n• . i rt 33 :,p n_a�y ,:Vv...z ...,:if, . .. !: `i :I' h $ f3r!� eP f. � L �i�4k .h d. � .: t� P C F: L' . �., �e IIII' 'i+n''� i" hI v.E+ �,r9�:: �E I. ��.. �€.. fi.trt i N.G. _ ,.. �`.:. :n•�t iy`ti 3:z ( .. v! 4 ?t � i :: �' W . l � °1 4: iE :,zu,.,n+i t h ,:3G4g,nu 1 ,. ' aS.i, i✓1 ::: _... . t .n..a'i'.{ ,a :. .. .....: :.. ...LL . .... ., ..... .. ....u. t ,.y:::;i: --t - cr ... - �. 4�....:.........I,...... u:. - #b AND LARGER G I I m:.,:...... LL , L. mu.e....v!h.a...a.3...Cu ..,E.n... tn....�a... ,Bv....x.. Y:{, - _ vn•I, ...:. .5 ... . ...IR, ...�.... .....Lr. l......t .., tE'. i. .., }...: ,. ... �:. _.... ........ ... .. _. o:i' ..... a...T ::�,nu ,.. nnn. 1 I I E..„,•i ... I i i. .. vt.... n. u,..0 .... .... ... ... ............ �l�E-.n.e.YE,.:.at.n,.,*E:...xi......... .... .........'i...r 3 Inns: ..,,.,=E' ,., n.S:.,.inn, �.i: :... .,:: n. t. ...Sd ..E t.. .. .. d... ..... .n, ... ..n .......,.E , . ...,.G_na .. n _ . ,nn..... n,....: t - v.. u n....i. en.n._: I::... .. L.... .,...a... ,. .L .. ..... ...... .. ..n . _w`{, u � .. ma. '. `�!' � ., ..nn ,n.". .,. vua: v LAP 4 x a... � .c. . , f<, E. '.FOP; ,.3 E , s. - ..na.: r..in .a. ��� ,.t�,..s .. �r3 ......,.: � IIII _ ,��� S f 1 _i LR..B . I , IIII I „ IIII :: NOT EXPOSED TO EARTH OR WEATHER I :....,. e ...... PPn k .... _ __� t....r � [� 3# 4( t P p ! U t. t. ES I d 't l(if I, : 3ft( 3}N 3 t! i k 3 , 3. 3 t3 3 E :" i, � G 45° _ I' 'v5y (. i E E � e"" ::.d t ..t !..i ,:.. a:,3E,a �..: %tlpEkn 5:.:l 7, ...:,, I•...,x .: :E+,�;i. t:'s.�v',.�n?.:`ri ,h _ f § ..a:.,�p S I..n,I � : ,q,,:.+3 I �;i'k � :t,v4.. :itl',..:i..: �5,. 5.:.h:...1Mat§€... 4`i kp.:..' IIII-_-_- - - _ ,:- -_--_- -I I I- ry IIII h:! k ALL REINFORCING BARS SHALL EXTEND AS FAR AS POSSIBLE AND 45° MAX. III -III Lh END IN A STANDARD 900 OR 1800 HOOK UNLESS DETAILED OTHERWISE I- =I I= I= -IIII_ IIII _I -IIII= I = - =111 L' ,3 p' 3" CLR.'E k "a I' E EII" I� 3" CLR. n 11-IIII-IIII-111. I = - - I -WIRE TOGETHER NOTE: (1) tt5 BAR TOP -1 -)III, (D tt5 BAR TOP AT EACH END SOME DETAIL HAS BEEN OMITTED AND BOTTOM AND BOTTOM BEND AROUND PIN FOR CLARITY (2 0 MIN.) UP TO tt4 BAR 12" TYP. 12" TYP. STIRRUPS AND TIES SPLICE Is 003 TYPICAL REINFORCING DETAILS oq HAIRPIN REINF. CLEARANCES 04 ADJACENT TO (E) OO4 o04 03 TYPICAL PERIMETER REV: 05 -30 -II CONCRETE_006-A SCALE: NONE 5-2.1 REV: 08-01-14 MS -FOUNDATION -205-A SCALE: NONES-2.1 REV: 08 -0I -I6 MB -FOUNDATION -100-C SCALE: I" = F-0" 5-2,1) -21 REV: 0-1-29-16 MB -FOUNDATION -100-B SCALE: 1" = 1'-0" VERTICAL REINFORCING: % VERTICAL REINFORCING: (4) 45 BARSIE (4) tt5 BARS 3'3av _ I i('4I s aY ", Ls fih3qifi t1Eli{tt tt,"n s�iJ=E€r.t':t PROVIDE. (3)-tt3 TIEStfl''j74 �E.yrk CONTAINING JUST BOLTS RMlIF ., i li{?• NOTE: iv NOTE: - - v iy E +t+ I-I/Y CLR. - i I I�yi- 4 E ... fi : 1-1/7 CLR. - REFER TO ANCHOR BOLT SETTING PLAN BY �..G1i °! . REFER TO ANCHOR BOLT SETTING PLAN BY METAL BUILDING MANUFACTURER FOR T g; METAL BUILDING MANUFACTURER FOR F i, E ADDITIONAL INFORMATION K I°3e 3i! :i24v ADDITIONAL INFORMATION i t ;, (:I; r �; r, HHH °i� t , SOME DETAIL OMITTED FOR CLARITY 4li IS,r SOME DETAIL OMITTED FOR CLARITY g',Infl d: METAL BUILDING GRID LINE �� METAL BUILDING GRID LINE CONCRETE PEDESTAL ATOP 12" L CONCRETE PEDESTAL ATOP IC, FOOTING. EXTEND TO BOTTOM FOOTING. EXTEND TO BOTTOM OF FLOOR SLAB. REFER TO BOLT PROJ. - SEE OF FLOOR SLAB. REFER TO BOLT PROJ. -- SEE FOOTING SCHEDULE FOR SIZE METAL BUILDING - FOOTING SCHEDULE FOR SIZE METAL BUILDING DRAWINGS DRAWINGS HAIRPIN - SEE 02/S-2.2 HAIRPIN - SEE 02/S-2.2 ANCHOR BOLTS SEE OR 03/8-2.2 FOR ANCHOR BOLTS - SEE OR 03/S-2.2 FOR FOUNDATION PLAN CONDITION AT BUILDING CORNER FOUNDATION PLAN CONDITION AT BUILDING CORNER CONCRETE SLAB - (3)-tt3 TIES IN UPPER a SEE FOUNDATION PLAN CONCRETE SLAB - l3)-tt3 TIES IN UPPER Fl SEE FOUNDATION PLAN 5" OF PEDESTAL 5" OF PEDESTAL; c Flu kocm 11 E4 a U tt tt TIES AT C O/C ,':1ilm'3 t; 4:5" tt3 TIES AT 8" O/CI„°rd k3 3 Z ..3..4,Y ,., _.. ...,..;.,5 ,. .ua. {, .1.,;,:�.,:.,.. ,'.t 3, t. ,..vn':H.d :-.3..Tn. MRm i iS+: Ii :I 111 +4+ iv3 E. .,. _. :4 ,,9 A:.�.. .:.:, I ,,µ, :,,;i , L ♦....,?krk .. .. .3Pb { t , is '!n..: i}Ein ,,,'. !§ IRc .... .. a..,. fi ,Pn v 39, .. ...: k r /� 04 r . n. .... _... .... ._ ... f kd ... ....: it :h { .c liu.{, .. ,4.. 'J_ ,! 3 .3': I I' 4 3 . ! E 5::_. :d....., r s..n .n..n n,6....n. ,v......... .. im...:..,fi ....z � 4 ri fi.. ..1 E Iro . d .........., ! h (. 3 . 4 .rf 6 , I ". .. v .:_ - &: i'4 n:,fi, n i v t E. (a. 4. S ... s .a .tX n s sa +�EE i .n.n: r. n. E; • ..m. unn..n.n. .4 nk,n.i;. F .... s.:, ,.. ..t 4 ., s T# i lJ ... ,.,.r • .n..nk.... ..:......:I:. .a.,n �..:,:�......,.,.,t..... .: 4 � ' �:m,....., . "{v.::......::., TOP OF FOOTING (TOE) - r a TOP OF FOOTING (TOF) + ''4fl �; i >`51tr ytl0l� �, BUTTE COUNTY DEVELOPMENT SERVICES :. ' Nl;'; itEty'al3t,. REVIEWED FOR �ya i 4 3�, �'I3 � 3333 p i. 3 yt4 -. -- DAT s w Date:CODE COMPLIANCE s s ...... ...tt...a ,? ... .. sE.. ... �,., •: t ah a :,{ .,:F n„v'�,m '� n, �:dn:aif:::m nn�:n 3:,il:iffi::3: �fiFi L, - .. .....E......nn,., ,. - n.... .5.aE ...3 t,7 :........_3 �:.... ..9 ..3 ,.I ..3 .. .I' ( - I : 1 - ... ... .5._n, ds ..... ... :. ::. .u.. n._ x.. k. .......... .. L... c. _ ,,.,. g I I p L., ,_.. .... .E"S .i v.,.., p}gj,4 P ,3 {I.I .,, .. Ea.d v: n..n.hu......a.ava_. vns, ...m...r..l..n ss .. , IN ,.t.t_n.33..... :,p[...._... . I PERIM. FOOTIN ,..... .� fi.. ..�..: �.: i.:. ...:.... {� ,. d..i. - PERIM. FOOT G t. .. _. ."-,, ,. ,.. fi,i.. w, .. I .n ...... .: .. .. ..... .','°.: 3,.Ei.`f!. .,3Ph .., n, :l,.,.: .,nd.,.,:,m,. n.6,.., ,, ,"'m .. a., : v.. ,_... 1.'{S .L: ... ., u i , , " ...... .....: �_, , - ... .. _ ., a -n z3 . , ..,, a ., .,, h. , .ne ,.," nm,, , . I _.:., :... ., .,.. F' .iv , ..... ... .....5.... " . I t ..... ..k .. III - o -F' t E. I .. ... }1iE . ... ..., 4.. .., .. S(- ... a,& .:.::... I :,.._E 3.lynE:..nL.rn..n:::;. II 3 I _ " !t. ! d . t !.. 3.. S fi h. .. .. ... ... ._ a ,.. i3,.v .. , ... ........ _, : i :-•i . I ,... .. ., BEYOND BEYOND a:,n .,.,t 1v„ ,., r„ : t, .nn in., : �..,y Y ,. _.. .,. ... ..e. .. ..: .n, ., a i. ..,. ,. ai a,n ,. .. ...tid3L Y. u..i. .............. .... F ':§ _ - ,... ,s _,"L:: t: n... 1 . .. E pp1 . _.., 4; i•: ..... _.,... a.._,.. :. :, E �' n... n.t ._nt6..... i .3......3........_,...,.n.n :: P __ n_, ...,. .. s ._ , ...... :......:.n ,i,4 ...,.A Iran ?I"::.::3.. h a pp t a.. ip...... n.tt,.,, _: ,., ., , .., . _ a 3 FRAME BOLT EMBEDMENT - Job nc h".... .tt 3e. ..... h'.i. .,.. .YS:.. ,.I x, H,, a!, ,. .. .. .. .. .. in. ..... ,.L EE§: a.. S a {:u..,"_1"'"3 . a... .. ..,. ..... i.. .. ,.... 3, n,... ..,.... .t..3.,ink....a ,,ti ._.., L.fii,3,knl (. IE. ....:. _....i pp nn Ha.'fi.nu.u,:Nvanz ..m i +..nii S.S. a ., vE t.L Y...i. u3d.aw Lu, i' ., t ,....:, h !_3a. ...n tEl �.Ia.,.uln.., ,.3i[u...eldd„ „ e..,vn ....., a .u,,,t ..... _.(.: :. _ , , :.. .,n :.... ., i'Lv. p .. ...:,: ! SI :n,zEi..... L.a._ , i I• t a , , t .. ..,.3 3.. :�• ..a- ....u::nr ., , , : .p, .,.. ,.., ., 3n, rx r. + i i .. :, G,;i,fitsL , gg a . ,., ..._ , ..nn .:,,n_t ._ r..., is v.. ,n, , n,,,v ,". :, i, ,: , 4n.,,v_. III (. ,i tin, sniff !,. v' .:. . . ... ... ....n, fisc._„_ : 6 .I Tim .... ... .. .... 31.1 A ::..,.5 ,. i p,. ,g. , .._ I .... ... ... L...... r.. .� ,..: ,. t .,EZ b� . n...r _E ,..... .....,, t..Z, .� .. E. .dL,..,.._F. ,. E 2 . ,.4th ....~fi... . , P. .t... ! ,.... _ ..::..t...6".. E.[iE.3 ..,.n SEE FOUNDATION PLANAND a_. ,., Ft ., ..n n.n?..._1_n...._ nt.�_n€kn._a..n�.n..,v.na.,-:,.... �p.:i .. .. a..,...... „ ,: _t , t ,E.... i"i '.i t. 0." 414#... .�E4 ,.: , ,:. S nn.... a.. :.4 , .a.a ,.t ...... ... .f r�. ,: m. �i ni .:. - E :. �i:...v .vS,i r,:, .. .nE, ,... F:. .E... .. u..CE E. .. .._,.... ',Tivv, a:.xmLv ,..., uv., ni,_ (( k� {w .... ...x.n., il., ._iv u.. ... -a.u. .a. ,_ v....., a 1 ,.,m. n.,, :u,::::1h+to- nsa,i `I , mmandn5n .i:e3n.:.L. ......r'`... {,. .:�•. 3,.,R.....,n av3ad unI 37 , .. ,.ehkz! ,. P ,.E4t. va. ..3.. .t C ., ;9DON ,... .... ...., i. ..n, i .._e ... 34 v., >..L.. a. ......�E... .,._u....aU.E:.o-. ,. ,n �:. a ,: ,,,. , , �: .,,, .iL,.,n t....t ..,... , 4 . n .,}�3 3". .....nh,.. L,.� o, ..,,...,,.,s,2n:�.E{a�nn�s. nen Lr...1 ._n.4 n3 :I,...S, : _ .. L ..... !. ...,...... ANCHOR BOLT SCHEDULE .3 a ., n,_t.1 ...... IL..... s., _n,n ., Ei :F ..t. .a.u,:.a n , :E .., , , ., E.. .•_ .. n,:ntp..,t..5446...#U �- w,4 ...,., ,.. .,, . + 5....n, .v d. ,R� ., n 'ik u t , ., .. i ..0 .... ..... .(, uEk.... .._. .......... .. ,4in:( �' " t3Mill. 4:. - ..u....., ip n , .. _._...£_I ......un @__._ ... _.. ,!. �,.. ... P {+ ,..E .. ., .:a. .... ! ....� C. 1, ,:. ..vN ....t.... :. .. ..... . r n ::. „'�.,.. ..,..4.4nd,6 G:,'4�.. 5..:,..[135,, ,.,.. ., �.. . w. _ , 3 :,;,: ISI � nt N ! n, t , t ,33,a ,4on _+�� _ , � � III 1I� PE, � �Fi � a: t ,, 3 5 Ii � l...EiR"s.ndb.: ,., 4:: uE.. a..ti u,rt�; " .4.:.. i i... - ,�, f31 ": I :IIE ,6. 43(3" v. :`. �}I .i .., .. .F T � e t+u, n ...es _ ,3y �3,. b .........:.,I ,{,. _ NO E THAT EMBEDMENT IS a. ..rtj -+a�sa,E - I + ,...+.I: - 4 ,....... YI _ She _ Si n 3 rbd:;" ,- : , .st t ', _ -. ,n+:� ...,t ...,.� h, ..SF. ... 3 .4:f.;m t.. ;;;_'m. !. :..,,L' 44:�kr.,hE's:I'¢i!""ut. MEASURED FROM TOP OF FOOTING (TOF) .., 6m,..,. ,,..: .. .1�r. v... t4. " +t p E ,. p .. , .. _ ,I c.. t .......3.....13:..... _ , , t : ,E_ i n, .1...: t " �n: ! n nn Y, . �. n n " k IIII , m §3 E< 3 t i I IIII 3 E I _, : n: I IIII �m iLm i :, I ,3 fr � �r 3 � �,� E III _ iM ,,_ , ,�. .vr R, b .3 3 .i �. 9E E. .. t::. ,. ...zi``v C.. :. I3 .... :fit ... :a .. .......... .. '.t:� !�„��� .....,., .F .._E........, . 4 , t IuNtS 3.: 4 P .: - ..... s.. �. .. "....:., 4:t}L.. „n ,I+,.: ,t,,.,:.,, , ..nn,.n.,. n3.,n .,:4 :::., 4.. v.. , . ....:...n.. .. ( [ ..:.. ...n;u.,. ITE, I[ ,3 ...h. -Ip 5'1E _..... .................:. r.. :. .. ..... .. .....:....:.:d:.0 . rL L, .. v $�'{� ,... .v.,,n., 'A S yy --..5a..k ..na5kd3nn5'r. n,ma n.i4mi u . ,yryL....., ..,i. i , iE�", t 1 \ - �/( .. .... ev:•:,..aun e.._ .... ,., n..tE, ..... W � � . . ?....._ .... §n..�:',.u+. PI;:. .. .. R m. .. :{'d_E,_.. a1... Eu'L. d .: . T 3vtt, , ., huu,f.. nn,_: matin....j E V I E�j���jjj,)j {'r'^ IE, .,, E. :F�iux.,,_:....... ._,... ...e... ._,3 .. ....... .... .. i, ... i :,, .m, lid„-t3,:n M V iw gT�,� ..,.. ..u, ... ,n.. a�+. u.. r. n. ...6.. ,.. ..,,,..:, Fnw § 3 „.. p t ,E, W r ..� . , iJ _ . E. 3 . .... ASYhn v ,:... m..... pp .,...,3L.: t na.,n, _:v.a..,:,n..na.,, ::u - -...n._,. ... ".:. � ... n�.. ._ _. a..4 ,. :,?,n1! ta7s d.n18,�SI h, 13fi,.Pk:.:,m„ nppl3 4 er ,. v:: .. E xpi, t4.. {.: ai$ , vt.n, t}n,, n...,,. ..,, :: g1,:.5ller. 4...E lL".3�.LL! � '..:... .1i.,4.3 l9r .., .:ii ,a.„i a „t,...: ,.,... r .., _,?. ,L: 3, ?...,- ., � i .ib: i!..., E� 3. §... ,?_3 df{i T _� ir, ., . ,ss.+, l a,.::a ..,, 7r.., t + .:. ...: t..,fi . 7 - 'S I' . 4>r n>x l :t:- v 4{,d...... ! ( - FOOTING -SEE PLAN IIII= _ Fbl� CODE COMPLIANCE _ I IIII= I I I I I III I- IIII-III _- FOOTING -SEE PLAN � i I I - FOR SIZE /REINFORCING IIII-IIII-IIII FOR SIZE/REINFORCING -I�-IIII- III NOV 10 2016. 001 I , 001 L. io TYPICAL FRAME FOOTING PEDESTAL 04 TYPICAL FRAME FOOTING - PEDESTAL CONSULTING GROI IP 5-2.1 REV: 08-01-16 MB -FOUNDATION -001_D SCALE: 1" 1'-0" S-2.1 REV: 0-1-29-16 MB-FOUNDATION_001-C SCALE: I" = 1'-0" I i cII i I LL. - 4 -2014 F.G. .. 15-051 et: >-2.1 of:. 111 I TTI cq t� O IN O) OD M OD OD ®m L V 0 10 N 86 3 i7 k tp v� OF to a M � aa 0 U O °v � 3333 p i. 3 yt4 -. -- DAT s w Date:CODE COMPLIANCE s s ...... ...tt...a ,? ... .. sE.. ... �,., •: t ah a :,{ .,:F n„v'�,m '� n, �:dn:aif:::m nn�:n 3:,il:iffi::3: �fiFi L, - .. .....E......nn,., ,. - n.... .5.aE ...3 t,7 :........_3 �:.... ..9 ..3 ,.I ..3 .. .I' ( - I : 1 - ... ... .5._n, ds ..... ... :. ::. .u.. n._ x.. k. .......... .. L... c. _ ,,.,. g I I p L., ,_.. .... .E"S .i v.,.., p}gj,4 P ,3 {I.I .,, .. Ea.d v: n..n.hu......a.ava_. vns, ...m...r..l..n ss .. , IN ,.t.t_n.33..... :,p[...._... . I PERIM. FOOTIN ,..... .� fi.. ..�..: �.: i.:. ...:.... {� ,. d..i. - PERIM. FOOT G t. .. _. ."-,, ,. ,.. fi,i.. w, .. I .n ...... .: .. .. ..... .','°.: 3,.Ei.`f!. .,3Ph .., n, :l,.,.: .,nd.,.,:,m,. n.6,.., ,, ,"'m .. a., : v.. ,_... 1.'{S .L: ... ., u i , , " ...... .....: �_, , - ... .. _ ., a -n z3 . , ..,, a ., .,, h. , .ne ,.," nm,, , . I _.:., :... ., .,.. F' .iv , ..... ... .....5.... " . I t ..... ..k .. III - o -F' t E. I .. ... }1iE . ... ..., 4.. .., .. S(- ... a,& .:.::... I :,.._E 3.lynE:..nL.rn..n:::;. II 3 I _ " !t. ! d . t !.. 3.. S fi h. .. .. ... ... ._ a ,.. i3,.v .. , ... ........ _, : i :-•i . I ,... .. ., BEYOND BEYOND a:,n .,.,t 1v„ ,., r„ : t, .nn in., : �..,y Y ,. _.. .,. ... ..e. .. ..: .n, ., a i. ..,. ,. ai a,n ,. .. ...tid3L Y. u..i. .............. .... F ':§ _ - ,... ,s _,"L:: t: n... 1 . .. E pp1 . _.., 4; i•: ..... _.,... a.._,.. :. :, E �' n... n.t ._nt6..... i .3......3........_,...,.n.n :: P __ n_, ...,. .. s ._ , ...... :......:.n ,i,4 ...,.A Iran ?I"::.::3.. h a pp t a.. ip...... n.tt,.,, _: ,., ., , .., . _ a 3 FRAME BOLT EMBEDMENT - Job nc h".... .tt 3e. ..... h'.i. .,.. .YS:.. ,.I x, H,, a!, ,. .. .. .. .. .. in. ..... ,.L EE§: a.. S a {:u..,"_1"'"3 . a... .. ..,. ..... i.. .. ,.... 3, n,... ..,.... .t..3.,ink....a ,,ti ._.., L.fii,3,knl (. IE. ....:. _....i pp nn Ha.'fi.nu.u,:Nvanz ..m i +..nii S.S. a ., vE t.L Y...i. u3d.aw Lu, i' ., t ,....:, h !_3a. ...n tEl �.Ia.,.uln.., ,.3i[u...eldd„ „ e..,vn ....., a .u,,,t ..... _.(.: :. _ , , :.. .,n :.... ., i'Lv. p .. ...:,: ! SI :n,zEi..... L.a._ , i I• t a , , t .. ..,.3 3.. :�• ..a- ....u::nr ., , , : .p, .,.. ,.., ., 3n, rx r. + i i .. :, G,;i,fitsL , gg a . ,., ..._ , ..nn .:,,n_t ._ r..., is v.. ,n, , n,,,v ,". :, i, ,: , 4n.,,v_. III (. ,i tin, sniff !,. v' .:. . . ... ... ....n, fisc._„_ : 6 .I Tim .... ... .. .... 31.1 A ::..,.5 ,. i p,. ,g. , .._ I .... ... ... L...... r.. .� ,..: ,. t .,EZ b� . n...r _E ,..... .....,, t..Z, .� .. E. .dL,..,.._F. ,. E 2 . ,.4th ....~fi... . , P. .t... ! ,.... _ ..::..t...6".. E.[iE.3 ..,.n SEE FOUNDATION PLANAND a_. ,., Ft ., ..n n.n?..._1_n...._ nt.�_n€kn._a..n�.n..,v.na.,-:,.... �p.:i .. .. a..,...... „ ,: _t , t ,E.... i"i '.i t. 0." 414#... .�E4 ,.: , ,:. S nn.... a.. :.4 , .a.a ,.t ...... ... .f r�. ,: m. �i ni .:. - E :. �i:...v .vS,i r,:, .. .nE, ,... F:. .E... .. u..CE E. .. .._,.... ',Tivv, a:.xmLv ,..., uv., ni,_ (( k� {w .... ...x.n., il., ._iv u.. ... -a.u. .a. ,_ v....., a 1 ,.,m. n.,, :u,::::1h+to- nsa,i `I , mmandn5n .i:e3n.:.L. ......r'`... {,. .:�•. 3,.,R.....,n av3ad unI 37 , .. ,.ehkz! ,. P ,.E4t. va. ..3.. .t C ., ;9DON ,... .... ...., i. ..n, i .._e ... 34 v., >..L.. a. ......�E... .,._u....aU.E:.o-. ,. ,n �:. a ,: ,,,. , , �: .,,, .iL,.,n t....t ..,... , 4 . n .,}�3 3". .....nh,.. L,.� o, ..,,...,,.,s,2n:�.E{a�nn�s. nen Lr...1 ._n.4 n3 :I,...S, : _ .. L ..... !. ...,...... ANCHOR BOLT SCHEDULE .3 a ., n,_t.1 ...... IL..... s., _n,n ., Ei :F ..t. .a.u,:.a n , :E .., , , ., E.. .•_ .. n,:ntp..,t..5446...#U �- w,4 ...,., ,.. .,, . + 5....n, .v d. ,R� ., n 'ik u t , ., .. i ..0 .... ..... .(, uEk.... .._. .......... .. ,4in:( �' " t3Mill. 4:. - ..u....., ip n , .. _._...£_I ......un @__._ ... _.. ,!. �,.. ... P {+ ,..E .. ., .:a. .... ! ....� C. 1, ,:. ..vN ....t.... :. .. ..... . r n ::. „'�.,.. ..,..4.4nd,6 G:,'4�.. 5..:,..[135,, ,.,.. ., �.. . w. _ , 3 :,;,: ISI � nt N ! n, t , t ,33,a ,4on _+�� _ , � � III 1I� PE, � �Fi � a: t ,, 3 5 Ii � l...EiR"s.ndb.: ,., 4:: uE.. a..ti u,rt�; " .4.:.. i i... - ,�, f31 ": I :IIE ,6. 43(3" v. :`. �}I .i .., .. .F T � e t+u, n ...es _ ,3y �3,. b .........:.,I ,{,. _ NO E THAT EMBEDMENT IS a. ..rtj -+a�sa,E - I + ,...+.I: - 4 ,....... YI _ She _ Si n 3 rbd:;" ,- : , .st t ', _ -. ,n+:� ...,t ...,.� h, ..SF. ... 3 .4:f.;m t.. ;;;_'m. !. :..,,L' 44:�kr.,hE's:I'¢i!""ut. MEASURED FROM TOP OF FOOTING (TOF) .., 6m,..,. ,,..: .. .1�r. v... t4. " +t p E ,. p .. , .. _ ,I c.. t .......3.....13:..... _ , , t : ,E_ i n, .1...: t " �n: ! n nn Y, . �. n n " k IIII , m §3 E< 3 t i I IIII 3 E I _, : n: I IIII �m iLm i :, I ,3 fr � �r 3 � �,� E III _ iM ,,_ , ,�. .vr R, b .3 3 .i �. 9E E. .. t::. ,. ...zi``v C.. :. I3 .... :fit ... :a .. .......... .. '.t:� !�„��� .....,., .F .._E........, . 4 , t IuNtS 3.: 4 P .: - ..... s.. �. .. "....:., 4:t}L.. „n ,I+,.: ,t,,.,:.,, , ..nn,.n.,. n3.,n .,:4 :::., 4.. v.. , . ....:...n.. .. ( [ ..:.. ...n;u.,. ITE, I[ ,3 ...h. -Ip 5'1E _..... .................:. r.. :. .. ..... .. .....:....:.:d:.0 . rL L, .. v $�'{� ,... .v.,,n., 'A S yy --..5a..k ..na5kd3nn5'r. n,ma n.i4mi u . ,yryL....., ..,i. i , iE�", t 1 \ - �/( .. .... ev:•:,..aun e.._ .... ,., n..tE, ..... W � � . . ?....._ .... §n..�:',.u+. PI;:. .. .. R m. .. :{'d_E,_.. a1... Eu'L. d .: . T 3vtt, , ., huu,f.. nn,_: matin....j E V I E�j���jjj,)j {'r'^ IE, .,, E. :F�iux.,,_:....... ._,... ...e... ._,3 .. ....... .... .. i, ... i :,, .m, lid„-t3,:n M V iw gT�,� ..,.. ..u, ... ,n.. a�+. u.. r. n. ...6.. ,.. ..,,,..:, Fnw § 3 „.. p t ,E, W r ..� . , iJ _ . E. 3 . .... ASYhn v ,:... m..... pp .,...,3L.: t na.,n, _:v.a..,:,n..na.,, ::u - -...n._,. ... ".:. � ... n�.. ._ _. a..4 ,. :,?,n1! ta7s d.n18,�SI h, 13fi,.Pk:.:,m„ nppl3 4 er ,. v:: .. E xpi, t4.. {.: ai$ , vt.n, t}n,, n...,,. ..,, :: g1,:.5ller. 4...E lL".3�.LL! � '..:... .1i.,4.3 l9r .., .:ii ,a.„i a „t,...: ,.,... r .., _,?. ,L: 3, ?...,- ., � i .ib: i!..., E� 3. §... ,?_3 df{i T _� ir, ., . ,ss.+, l a,.::a ..,, 7r.., t + .:. ...: t..,fi . 7 - 'S I' . 4>r n>x l :t:- v 4{,d...... ! ( - FOOTING -SEE PLAN IIII= _ Fbl� CODE COMPLIANCE _ I IIII= I I I I I III I- IIII-III _- FOOTING -SEE PLAN � i I I - FOR SIZE /REINFORCING IIII-IIII-IIII FOR SIZE/REINFORCING -I�-IIII- III NOV 10 2016. 001 I , 001 L. io TYPICAL FRAME FOOTING PEDESTAL 04 TYPICAL FRAME FOOTING - PEDESTAL CONSULTING GROI IP 5-2.1 REV: 08-01-16 MB -FOUNDATION -001_D SCALE: 1" 1'-0" S-2.1 REV: 0-1-29-16 MB-FOUNDATION_001-C SCALE: I" = 1'-0" I i cII i I LL. - 4 -2014 F.G. .. 15-051 et: >-2.1 of:. 111 I TTI �T N 86 3 i7 REN �IF, 9TF OF U U LLI I- ul 7 )� O � z U- < Lu E) 'IQ � 3333 p i. 3 yt4 -. -- DAT s w Date:CODE COMPLIANCE s s ...... ...tt...a ,? ... .. sE.. ... �,., •: t ah a :,{ .,:F n„v'�,m '� n, �:dn:aif:::m nn�:n 3:,il:iffi::3: �fiFi L, - .. .....E......nn,., ,. - n.... .5.aE ...3 t,7 :........_3 �:.... ..9 ..3 ,.I ..3 .. .I' ( - I : 1 - ... ... .5._n, ds ..... ... :. ::. .u.. n._ x.. k. .......... .. L... c. _ ,,.,. g I I p L., ,_.. .... .E"S .i v.,.., p}gj,4 P ,3 {I.I .,, .. Ea.d v: n..n.hu......a.ava_. vns, ...m...r..l..n ss .. , IN ,.t.t_n.33..... :,p[...._... . I PERIM. FOOTIN ,..... .� fi.. ..�..: �.: i.:. ...:.... {� ,. d..i. - PERIM. FOOT G t. .. _. ."-,, ,. ,.. fi,i.. w, .. I .n ...... .: .. .. ..... .','°.: 3,.Ei.`f!. .,3Ph .., n, :l,.,.: .,nd.,.,:,m,. n.6,.., ,, ,"'m .. a., : v.. ,_... 1.'{S .L: ... ., u i , , " ...... .....: �_, , - ... .. _ ., a -n z3 . , ..,, a ., .,, h. , .ne ,.," nm,, , . I _.:., :... ., .,.. F' .iv , ..... ... .....5.... " . I t ..... ..k .. III - o -F' t E. I .. ... }1iE . ... ..., 4.. .., .. S(- ... a,& .:.::... I :,.._E 3.lynE:..nL.rn..n:::;. II 3 I _ " !t. ! d . t !.. 3.. S fi h. .. .. ... ... ._ a ,.. i3,.v .. , ... ........ _, : i :-•i . I ,... .. ., BEYOND BEYOND a:,n .,.,t 1v„ ,., r„ : t, .nn in., : �..,y Y ,. _.. .,. ... ..e. .. ..: .n, ., a i. ..,. ,. ai a,n ,. .. ...tid3L Y. u..i. .............. .... F ':§ _ - ,... ,s _,"L:: t: n... 1 . .. E pp1 . _.., 4; i•: ..... _.,... a.._,.. :. :, E �' n... n.t ._nt6..... i .3......3........_,...,.n.n :: P __ n_, ...,. .. s ._ , ...... :......:.n ,i,4 ...,.A Iran ?I"::.::3.. h a pp t a.. ip...... n.tt,.,, _: ,., ., , .., . _ a 3 FRAME BOLT EMBEDMENT - Job nc h".... .tt 3e. ..... h'.i. .,.. .YS:.. ,.I x, H,, a!, ,. .. .. .. .. .. in. ..... ,.L EE§: a.. S a {:u..,"_1"'"3 . a... .. ..,. ..... i.. .. ,.... 3, n,... ..,.... .t..3.,ink....a ,,ti ._.., L.fii,3,knl (. IE. ....:. _....i pp nn Ha.'fi.nu.u,:Nvanz ..m i +..nii S.S. a ., vE t.L Y...i. u3d.aw Lu, i' ., t ,....:, h !_3a. ...n tEl �.Ia.,.uln.., ,.3i[u...eldd„ „ e..,vn ....., a .u,,,t ..... _.(.: :. _ , , :.. .,n :.... ., i'Lv. p .. ...:,: ! SI :n,zEi..... L.a._ , i I• t a , , t .. ..,.3 3.. :�• ..a- ....u::nr ., , , : .p, .,.. ,.., ., 3n, rx r. + i i .. :, G,;i,fitsL , gg a . ,., ..._ , ..nn .:,,n_t ._ r..., is v.. ,n, , n,,,v ,". :, i, ,: , 4n.,,v_. III (. ,i tin, sniff !,. v' .:. . . ... ... ....n, fisc._„_ : 6 .I Tim .... ... .. .... 31.1 A ::..,.5 ,. i p,. ,g. , .._ I .... ... ... L...... r.. .� ,..: ,. t .,EZ b� . n...r _E ,..... .....,, t..Z, .� .. E. .dL,..,.._F. ,. E 2 . ,.4th ....~fi... . , P. .t... ! ,.... _ ..::..t...6".. E.[iE.3 ..,.n SEE FOUNDATION PLANAND a_. ,., Ft ., ..n n.n?..._1_n...._ nt.�_n€kn._a..n�.n..,v.na.,-:,.... �p.:i .. .. a..,...... „ ,: _t , t ,E.... i"i '.i t. 0." 414#... .�E4 ,.: , ,:. S nn.... a.. :.4 , .a.a ,.t ...... ... .f r�. ,: m. �i ni .:. - E :. �i:...v .vS,i r,:, .. .nE, ,... F:. .E... .. u..CE E. .. .._,.... ',Tivv, a:.xmLv ,..., uv., ni,_ (( k� {w .... ...x.n., il., ._iv u.. ... -a.u. .a. ,_ v....., a 1 ,.,m. n.,, :u,::::1h+to- nsa,i `I , mmandn5n .i:e3n.:.L. ......r'`... {,. .:�•. 3,.,R.....,n av3ad unI 37 , .. ,.ehkz! ,. P ,.E4t. va. ..3.. .t C ., ;9DON ,... .... ...., i. ..n, i .._e ... 34 v., >..L.. a. ......�E... .,._u....aU.E:.o-. ,. ,n �:. a ,: ,,,. , , �: .,,, .iL,.,n t....t ..,... , 4 . n .,}�3 3". .....nh,.. L,.� o, ..,,...,,.,s,2n:�.E{a�nn�s. nen Lr...1 ._n.4 n3 :I,...S, : _ .. L ..... !. ...,...... ANCHOR BOLT SCHEDULE .3 a ., n,_t.1 ...... IL..... s., _n,n ., Ei :F ..t. .a.u,:.a n , :E .., , , ., E.. .•_ .. n,:ntp..,t..5446...#U �- w,4 ...,., ,.. .,, . + 5....n, .v d. ,R� ., n 'ik u t , ., .. i ..0 .... ..... .(, uEk.... .._. .......... .. ,4in:( �' " t3Mill. 4:. - ..u....., ip n , .. _._...£_I ......un @__._ ... _.. ,!. �,.. ... P {+ ,..E .. ., .:a. .... ! ....� C. 1, ,:. ..vN ....t.... :. .. ..... . r n ::. „'�.,.. ..,..4.4nd,6 G:,'4�.. 5..:,..[135,, ,.,.. ., �.. . w. _ , 3 :,;,: ISI � nt N ! n, t , t ,33,a ,4on _+�� _ , � � III 1I� PE, � �Fi � a: t ,, 3 5 Ii � l...EiR"s.ndb.: ,., 4:: uE.. a..ti u,rt�; " .4.:.. i i... - ,�, f31 ": I :IIE ,6. 43(3" v. :`. �}I .i .., .. .F T � e t+u, n ...es _ ,3y �3,. b .........:.,I ,{,. _ NO E THAT EMBEDMENT IS a. ..rtj -+a�sa,E - I + ,...+.I: - 4 ,....... YI _ She _ Si n 3 rbd:;" ,- : , .st t ', _ -. ,n+:� ...,t ...,.� h, ..SF. ... 3 .4:f.;m t.. ;;;_'m. !. :..,,L' 44:�kr.,hE's:I'¢i!""ut. MEASURED FROM TOP OF FOOTING (TOF) .., 6m,..,. ,,..: .. .1�r. v... t4. " +t p E ,. p .. , .. _ ,I c.. t .......3.....13:..... _ , , t : ,E_ i n, .1...: t " �n: ! n nn Y, . �. n n " k IIII , m §3 E< 3 t i I IIII 3 E I _, : n: I IIII �m iLm i :, I ,3 fr � �r 3 � �,� E III _ iM ,,_ , ,�. .vr R, b .3 3 .i �. 9E E. .. t::. ,. ...zi``v C.. :. I3 .... :fit ... :a .. .......... .. '.t:� !�„��� .....,., .F .._E........, . 4 , t IuNtS 3.: 4 P .: - ..... s.. �. .. "....:., 4:t}L.. „n ,I+,.: ,t,,.,:.,, , ..nn,.n.,. n3.,n .,:4 :::., 4.. v.. , . ....:...n.. .. ( [ ..:.. ...n;u.,. ITE, I[ ,3 ...h. -Ip 5'1E _..... .................:. r.. :. .. ..... .. .....:....:.:d:.0 . rL L, .. v $�'{� ,... .v.,,n., 'A S yy --..5a..k ..na5kd3nn5'r. n,ma n.i4mi u . ,yryL....., ..,i. i , iE�", t 1 \ - �/( .. .... ev:•:,..aun e.._ .... ,., n..tE, ..... W � � . . ?....._ .... §n..�:',.u+. PI;:. .. .. R m. .. :{'d_E,_.. a1... Eu'L. d .: . T 3vtt, , ., huu,f.. nn,_: matin....j E V I E�j���jjj,)j {'r'^ IE, .,, E. :F�iux.,,_:....... ._,... ...e... ._,3 .. ....... .... .. i, ... i :,, .m, lid„-t3,:n M V iw gT�,� ..,.. ..u, ... ,n.. a�+. u.. r. n. ...6.. ,.. ..,,,..:, Fnw § 3 „.. p t ,E, W r ..� . , iJ _ . E. 3 . .... ASYhn v ,:... m..... pp .,...,3L.: t na.,n, _:v.a..,:,n..na.,, ::u - -...n._,. ... ".:. � ... n�.. ._ _. a..4 ,. :,?,n1! ta7s d.n18,�SI h, 13fi,.Pk:.:,m„ nppl3 4 er ,. v:: .. E xpi, t4.. {.: ai$ , vt.n, t}n,, n...,,. ..,, :: g1,:.5ller. 4...E lL".3�.LL! � '..:... .1i.,4.3 l9r .., .:ii ,a.„i a „t,...: ,.,... r .., _,?. ,L: 3, ?...,- ., � i .ib: i!..., E� 3. §... ,?_3 df{i T _� ir, ., . ,ss.+, l a,.::a ..,, 7r.., t + .:. ...: t..,fi . 7 - 'S I' . 4>r n>x l :t:- v 4{,d...... ! ( - FOOTING -SEE PLAN IIII= _ Fbl� CODE COMPLIANCE _ I IIII= I I I I I III I- IIII-III _- FOOTING -SEE PLAN � i I I - FOR SIZE /REINFORCING IIII-IIII-IIII FOR SIZE/REINFORCING -I�-IIII- III NOV 10 2016. 001 I , 001 L. io TYPICAL FRAME FOOTING PEDESTAL 04 TYPICAL FRAME FOOTING - PEDESTAL CONSULTING GROI IP 5-2.1 REV: 08-01-16 MB -FOUNDATION -001_D SCALE: 1" 1'-0" S-2.1 REV: 0-1-29-16 MB-FOUNDATION_001-C SCALE: I" = 1'-0" I i cII i I LL. - 4 -2014 F.G. .. 15-051 et: >-2.1 of:. 111 I TTI ' u �' f i f TILT III Revisions: � 'nn v! � 20' HAIRPIN - �Q LLJ SEE FOUNDATION Z z PLAN FOR SIZE fV FRAME Q O v l q il Q Q q � °° i _�� s i i' 6� ''.. �I�`r° : �� h3F � y�: r 3!••i: tPI�7r�s }s vk r� k c §h st ° �` r 3• t E E,F �l Lv STANDARD HOOK NOTE:::£to; AT END — 12 t 1E= SEE IS/S-2.1 44 REFER TO DETAIL 09/S-2.1 FOR ADDITIONAL INFORMATION REGARDING CLEARANCES AT HAIRPINS OS SINGLE HAIRPIN - CORNER S-2.2 REV: 04-06-14 MB -FOUNDATION -201-C SCALE: NONE 20' HAIRPIN — SEE FOUNDATION I n I 21 Vin. - PLAN FOR SIZE £ ° �:$���Y fi, '2� i E t3I I ,�y+; � .. !: }F;•.h kr � fi F S "L, SI r+TNEt k gE! tE 3 yh'k S'nrk is E. Ego !' 3IsP�si:ti`xs t$`.y''r FRAME ;`r•ask int I �.:ttll! °(E .�`Ea.r L9 I! r�F Eye iC ! 7143 t� !(iV't Cril t:fEt `jR P � t :rL t'�E flv"`sii� S, 4 Y EL Y Xi aPt�t, tit jy' i ATAEND RD HOOK NOTE: xF9:lBF� E.Y vf.;a SEE 15/5-2.1 REFER TO DETAIL 09/5-2.1 FOR ADDITIONAL INFORMATION REGARDING CLEARANCES AT HAIRPINS 001 02 SINGLE HAIRPIN 5-2.2 REV: 04-06-14 MB -FOUNDATION -201-A SCALE: NONE NOTE: REINFORCING STEEL SHALL BE LOCATED IN UPPER HALF OF SLAB AS SHOWN. REINFORCING STEEL TO BE HELD IN POSITION WITH CONCRETE "DOBIES", OR OTHER APPROVED METHOD. REINFORCING STEEL — SEE DRAWINGS 4". CONCRETE SLAB - VISQUEEN K J V T, IN= ���� , IIII ILII VIII -1111 — I I j- 2" GRANULAR BASE LAYER - OVER VISQUEEN MIN. 4" GRAVEL FILL PERMIT# ., � - REVIEWED E3U,fTkbbUNtvDEVELOPMENT SERVICES FOR CODE COMPLIANCE FOR ,hEVIEWED 610COMPLIANCE / `/ NOV 10 2016 JbrE INTERWEST oI CONCRETE SLAB ASSEMBLY - S-2.2 REV: 04-26-11 CONCRETE -001_B SCALE: 1-1/2" = I' -O" ' u �' f i f TILT III Revisions: Date: 6-2016 Drawn: F.G. Job no.: IS -051 REVISION DATE: 08-01-16 I i � ulfl i lUi�'11 � 'nn v! � �Q LLJ Z z fV LL Q O v l Z Q Q � i Date: 6-2016 Drawn: F.G. Job no.: IS -051 REVISION DATE: 08-01-16 I i � ulfl i lUi�'11 ELEGTRIGAL SYMBOLS 15 OR 20 AMP 125V DUPLEX RECEPTACLE ® +18" UNO 15 OR 20 AMP 125\1 5FIC DUPLEX RECEPTACLE ® +18" UNO SPECIAL OUTLET - SEE PLANS FOR SPEGIFICTION S 51NSLE POLE TO66LE SWITCH, ® +46" UNO 52 DOUBLE POLE TO66LE 5WITGH, ® +46" UNO O JUNCTION BOX, 517E t TYPE A5 INDICATED OR REQUIRED 0/ DISCONNECT 5WITGH ® PANEL.BOARD, MOUNTED AS NOTED ON PANEL SCHEDULE O FIXTURE TYPE 0 FLUORESCENT OR LED LIGHT FIXTURE - SURFACE OR PENDANT MOUNTED LI6HT FIXTURE - WALL MOUNTED ® EXIT LIGHT - GEILIN6 OR WALL MOUNTED EMER5SENGY/EXIT LIGHT WITH BATTERY BACK UP SIDE -MOUNT LAMP HEADS GU MECHANICAL EQUIPMENT DESIGNATION / MOTOR 'rVC" CONDUIT RUN CONGEALED BELOW FLOOR OR FIN15HW GRADE "EMT" CONDUIT RUN ON KAL.L OR CEILING HOMERUN TO RESPECTIVE PANEL OR TERMINAL CABINET - "PVC" UNDERGROUND HOMERUN TO RESPECTIVE PANEL OR TERMINAL CABINET - "EMT" OVERHEAD ,\� DENOTES # OF WIRES. NO MARKS = 2 #12, I/2"G; CURVED HATCH DENOTES A'1\1 GROUND WIRE. WIRE 517E INDICATED WHEN OTHER THAN #12. eDETAIL DE516NATION: TOP NUMBER INDICATES DETAIL, BOTTOM LETTERUI MEER INDICATES SHEET IG 150LATED GROUND NL NIGHT LIGHT - UNSWITCHED FIXTURE WP WEATHERPROOF NIT EMPTY CONDUIT WITH PULLSTRING (Fa EXISTING NIE5 NOT IN ELECTRICAL SECTION OF THESE PLANS t SPECS UNO UNLESS NOTED OTHERWISE (E) Panel - H MOUNTING: Surface Mount Nema 3R TYPE Cutler Hammer Panel Board 200 amp 277/480 volt 3 phase 4 w ire Main Breaker Cir.# Description BRKR. POLE A B C A B C BRKR. POLE Description Cir.# 1 Warehouse Lighting 20 1 3324 70W LED 15+1 -Surface 3324 Lithonia AFNDBEXT 20 1 Warehouse Lighting 2 3 Warehouse Lighting 20 1 I m.voItI 3324 1 9'+/ -Surface 3324 z Q 20 1 Warehouse Lighting 4 5 Exterior wall pack lighting 20 1 COMPLIANCE AITH SEG. 110.26 TO BE PROVIDED Of Sheets 1662 I 1939 30 3 (N) High Speed Door 6 7 (N) Warehouse Lighting 20 1 997 1 1939 18001 9001 20 1 8 9 9 (N)Battery Charger 30 2 1260 I 1939 1 I 1 I 10 11 10 11 SERVICE EQUIPMENT. 125/3 1260 12 13 12 13 14 15 14 15 PANELBOARD5 SUPPLIED BY A FEEDER INGROUND 16 17 16 17 OTHER THAN ONE OR TWO FAMILY DWELLINGS BUSS 18 19 18 19 SHALL BE MARKED TO INDICATE THE DEVICE _ I 1/2"0 20 21 20 21 OR EQUIPMENT WHERE THE POWER SUPPLY 3-#2 1 1 1 22 23 22 23 NSTALILED FOR ORIGINATES. I -#b GRD 24 25 24 25 1-#4 GRD FUTURE DEVELOPMENT 900 60 3 Transformer T 26 27 26 27 PANEL 780 28 28 29 LFUTURE J AG 360 30 1980 1980 30 1260 4321 3324 1662 6163 6043 2299 10484 9367 3961 Panel Load: 23812 = 28 Amps 28 x125% _ (E) Panel - L 35 Am MOUNTING: Surface Name 3R TYPE Cutler Hammer Panel Board 200 amp 120/208 volt 3 phase 4 w ire 125 amp main breaker Cir.# Description BRKR. POLE A B C A B C BRKR. POLE Description Cir.# 1 Bug/Fumigation Receptacle 20 1 180 70W LED 15+1 -Surface 360 Lithonia AFNDBEXT 20 1 Convenience receptacles 2 3 (N) Parts service receptacles 20 1 I m.voItI 720 1 9'+/ -Surface 180 z Q 20 1 Convenience receptacles 4 5 (N) Weider receptacle 50 2 COMPLIANCE AITH SEG. 110.26 TO BE PROVIDED Of Sheets 1800 I 180 20 1 Panel receptacle 6 7 1 1 1 1 18001 9001 20 1 (N) Warehouse receptacles 8 9 (N)Battery Charger 30 2 1260 I 1 I 1 I 10 11 SPACE SPACE SPACE SERVICE EQUIPMENT. 125/3 1260 12 13 14 15 PANELBOARD5 SUPPLIED BY A FEEDER INGROUND 16 17 OTHER THAN ONE OR TWO FAMILY DWELLINGS BUSS 18 19 SHALL BE MARKED TO INDICATE THE DEVICE _ I 1/2"0 20 21 OR EQUIPMENT WHERE THE POWER SUPPLY 3-#2 1 1 1 1 2"G 22 23 NSTALILED FOR ORIGINATES. I -#b GRD -#b GRD 24 25 1-#4 GRD FUTURE DEVELOPMENT 3/0 COPPER GROUND TR5NF. Il-Ell112!SKVA 26 27 PANEL 28 29 LFUTURE J AG 30 1980 1980 3060 1260 180 180 32401 21601 3240 Panel Load: 8640 = 24 Amps 24 x125% = 30 Amps Lighting Fixture Schedule Type Manuf. Catalog Number Description Volt. I Lamps Mounting A Lighting System PMOL-LED-VHO-CW-UE-OCS-PMX-,6sensor LED High bay w/ embedded motion m.volt 111WLED Air Craft Cable Suspended B Econolight E-WP13LO7UCZ LED full cutoff wall pack m.volt 70W LED 15+1 -Surface C Lithonia AFNDBEXT Exterior emergency egress light m.volt included 9'+/ -Surface D Lithonia LHQMLED3GM6 I Illuminated emergency exit light I m.voItI included 1 9'+/ -Surface rkJm Uuut UUMPLIANCE PERMITt�i�I�-�"TE NOV ' OOti BUTCOUNTY DEVELOPMENT SERVICES REVIEWED FOR CODE COMPLIANCE F-LEGTRI GAL PLAN - NEW BUILDING INTERWEST DATE Ct7NS111 71Ntr_ ronr in SCALE = 1/5" = PO" --' r-- - - it i F I q Ir REVISIONS A PLAN CHECK I q/2 f/I6 MT (E) ETER 5Y41TCHBOARD "MSB" NEMA 3R UNDERGROUND PULL 5EGTION _ EY NOTES V z _ _ _ P lu 500A 480\/ 3PH 4W BU55 nice w" 7J-1 0 Mug V O v x u I. LABEL FOR ARG-FLA514 HAZARD Y4ARNING INI I M M z z Q .1n z r m Date 05/201/I6 Scale SHOWN Drawn ABMT Job Sheet COMPLIANCE AITH SEG. 110.26 TO BE PROVIDED Of Sheets I BY PANEL MANUFACTURER. PROVIDE PROVISION 150/3 115/3 200/3 200/3 400/3 100/3 FOR POSTING MAXIMUM ARG -FAULT CURRENT AT I I I I SPACE SPACE SPACE SERVICE EQUIPMENT. 125/3 2. SOURCE OF SUPPLY. ALL SWITCHBOARDS AND PANELBOARD5 SUPPLIED BY A FEEDER INGROUND OTHER THAN ONE OR TWO FAMILY DWELLINGS BUSS SHALL BE MARKED TO INDICATE THE DEVICE _ I 1/2"0 2"0 OR EQUIPMENT WHERE THE POWER SUPPLY 3-#2 3-I/0 2"G 4-3/0 NSTALILED FOR ORIGINATES. I -#b GRD -#b GRD 4-2/O 1-#4 GRD FUTURE DEVELOPMENT 3/0 COPPER GROUND TR5NF. Il-Ell112!SKVA -#6 GRD PANEL LFUTURE J AG WELL UPPER, METAL, 120/240V 3PH 4A REFRIG- W GAS, ATER ERA BOND AS E PANEL L 5 3-#6 REQUIRED — GRD PER NECJ4-#2 250-414 TR5NF. T" SERVICE CONDUITS6 CONDUCTORS45KVR PER UTILITY COMPANY 120/205REQUIREMENTS 3PH 4A = 1 1/4"C 4-#2 I -#b GRD 1!t NOTE: ALL SUB PANELS RATED 10,000 AIG (E) ONE LINE D I A6RAM NO 5GALE rkJm Uuut UUMPLIANCE PERMITt�i�I�-�"TE NOV ' OOti BUTCOUNTY DEVELOPMENT SERVICES REVIEWED FOR CODE COMPLIANCE F-LEGTRI GAL PLAN - NEW BUILDING INTERWEST DATE Ct7NS111 71Ntr_ ronr in SCALE = 1/5" = PO" --' r-- - - it i F I q Ir REVISIONS BY PLAN CHECK I q/2 f/I6 MT V z P lu 7J-1 0 Mug V O v x u UA O ('� O Q �J UU z z Q .1n z r m Date 05/201/I6 Scale SHOWN Drawn ABMT Job Sheet EI Of Sheets STATE OF CALIFORNIA Conditioned Floor Area:4,990SU FT STATE OF CALIFORNIA INDOOR LIGHTING X NRCC-LIT-Ol-E INDOOR LIGHTING CEO NRCC{T t£RaAer10613 -_,-_ CALIFORNIAENERGYGOMMISSION rv. GEC�RCCITI-OS-E(R 'sad Ofi l3) _____ CERTIFICATE OF COMPLIANCE- USER INSTRUCTIONS - NRCC-LTIJ05)) Tailored Method Worksheets General information CERTIFICATE OF COMPLIANCE- USER INSTRUCTIONS Indoor-Ughting (Pagel 1. Indoor Lighting PmjeetName: ADDITION FOR MAI SIEJANE Dale Pre ared:612912016 Residential High -Rise❑ Conditioned Spaces X Protect Name ADDITION FOR MAGIE JANE I Phase of Construction: ❑ New Construction --- _P Addition Climate Zone: 11 Conditioned Floor Area:4,990SU FT YES NO FORM TITLE X NRCC-LIT-Ol-E Certificate of Compliance: All Pages required on pians for all submittals. X NRCC-LIT-02-E Unconditioned Floor Area.: X NRCC-LIT-03-E Indoor Lighting Power Allowance X NRCC-LIT-04-E Tailored Method Worksheets General information Line Voltage Lighting Worksheets g g g X NRCI-LTI-03-E- Must be submitted fare line -voltage track lighting integral current limiter, Orford supplementary overeurrent protection panel used to energize only line -voltage track lighting, to be recognized for compliance. 1. NRCC-LTI-01.-F. age4 Building Type: EJ Schools Nonresidential b e P lie cools Relocata Public Schools h NRCC-LTI-01._E, page Residential High -Rise❑ Conditioned Spaces X Hotel Motel / Unconditioned 5 aces P Phase of Construction: ❑ New Construction ® Addition ❑ Alteration Method of Compliance: ❑ Complete Building ® Area Category ❑ Tailored LIGHTING COMPLIANCE DOCUMENTS (select Yes for each document included) - 1 r r theN nresid pial Manuel published the CaliforniaEner Commission. Fardemiled instruct'ons on the use n'this and ofl Ener E idem Stnnrlords compliance roc truants refer o e 9Y I Y ry I P Y I 1 y f! P YES NO FORM TITLE X NRCC-LIT-Ol-E Certificate of Compliance: All Pages required on pians for all submittals. X NRCC-LIT-02-E Lighting Controls, Certificate of Com liance and PAF Calculation, All Pages required un plains for all submittals. Ll�h 6C P B 9 P X NRCC-LIT-03-E Indoor Lighting Power Allowance X NRCC-LIT-04-E Tailored Method Worksheets NRCC-LT-05-E X i Line Voltage Lighting Worksheets g g g Summa of Allowed Lighting Power N $ $ Conditioned and Unconditioned space Lighting must not be combined for compliance. Indoor Lighting Power for Conditioned Spaces Indoor lighting Power for Unconditioned Spaces 6. Allowed Lighting Power Conditioned NP,CC-LTF03-E, page 1 Watts NRCI-LTI-01-E-Mustleesubmitted forth buildings Watts X Installed Lighting Installed Lighting ❑ Field Ins ector 999 X NRCI-LTI-03-E- Must be submitted fare line -voltage track lighting integral current limiter, Orford supplementary overeurrent protection panel used to energize only line -voltage track lighting, to be recognized for compliance. 1. NRCC-LTI-01.-F. age4 + NRCI-LTI-04-E- Must he submitted for two interlocked systems serving an auditorium, a convention center, a conference room, a multipurpose room, or a theater to be recognized for compliance. NRCC-LTI-01._E, page + X 2' PORTABLE ONLY FOR OFFICES + 0. NRCI-LTI-06-E - Must be submitted for additional wattage installed in a video conferencing studio to be recognized for compliance. Field Inspector NRCC-I.TL01-E,page 3 ❑ All lighting controls and equipment pshall comply with the applicable requirements in 4110.9 and shall be installed in accordance with the manufacturer's @ @ c v r; � 2 O _ Minus Lighting Control Credits ® 0 Minus Lighting Control Credits Job z 3 NRCC-LFI-OI-E, page 2 ® and special effects lighting shall each be separately controlled on circuits that are 20 amps or less. When track lighting is used, general, display, NRCC-LTI-01-E, page 2 Identify office area In whkh ornamental, and special effects lighting shall each be separately controlled; in accordance with Section 130.0(a)4. ❑ Adjusted Installed Lighting Power The general lighting of any enclosed area 100 square feet or larger, with a connected lighting load that exceeds 0.5 watts per square foot shall meet the 999 Adjusted Installed Lighting Power multi-level lighting control requirements in accordance with Section 130.1(b). ® 4. (raw S plus raw 2 minus row 3) _ 0 (row 1 minus row 3 _ ® CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance STA OOF CALIFORNIA INDOOR LIGHTING CEC-NRCCiTI-m E EiMaPtd g6n3]_ _ _ __ _ CERTIFICATE OF COMPLIANCE USER INSTRUCTIONS Indoor Lighting PratnR Name: Anne ION FOR MAISIE JANE June 2013 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT - 1 I certify that this Certificate Df Compliance documentation is accurate and complete. }� prumenravil Auld,. Na ne: D: ,taCr,Au!ItorFynet,[e is to JOSH SCOTT ✓.` _W_ rsmnaoy st"im, Dace: PACE E N GIN E E RI N G 8/29/2016 Address: CIA/ HERS ceritkoClon EnrPor&offin is applicabld.. 1730 SOUTH ST NA crylbas ip: Phone: REDDING,CA96001 _ 530-244-0202 RESPONSIBLE PERSON'S DECLARATION STATEMENT I rietify dm following under penalty of perjury, under the laws of the State, of California: T information provided on this Certificate of Com liance is true and correct. 1. he p p 2. 1 am eligible under Division 3 of the Business and Professions Code to accent responsibility for the building design or system design Identitl ed on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of r� ' n o Title 24 Part 1 n Raft f the California Code of Regulations Compliance conform to the _quveme is of l e and o g 4. The building design features or system design features Identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, wovsheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.. 5. 1 will ensure that a comploted signed copy of this Certificate of Compliance shall be made available with the building permitls) issued for the building, and made available to the enforcement agency for all applicable inspections. l understand that a completed signed copy of this Certificate of Compliance is required to be induced with the documentation the builder provides to the building owner at occupancy. Reapontb'i, Drogner drama: R opurI DiAiA rSianatkil / CHRIS ABRAHAMSEN !,+r^'"'7"- Company' Dare sse:ec' PACE ENGINEERING ____ 8/29/2016 Adders hermse. 1730 SOUTH ST E012726 --_ OglaYate1,1, Niece: REDOING CA 96001 -_ 530-244-0202 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance NRCC-LTC01-E B/29/2016 5. Compiles ONLY if Installed s Allowed Complies ONLY if Installed s Allowed E 6. Allowed Lighting Power Conditioned NP,CC-LTF03-E, page 1 4,990 Allowed lighting Power Unconditioned NRCC-LTI-03-E, page 1 NRCI-LTI-01-E-Mustleesubmitted forth buildings Declaration of Required Installation Certificates -Declare by selecting yes for all Installation Certificates that wilt be submitted. (Retain copies and verify forms are completed and signed.) YES NO Form/Title ❑ Field Inspector X ❑ Field Inspector NRCI-LTI-01-E-Mustleesubmitted forth buildings ❑ Fieldinspector X Efficiency Regulations in accordance with Section 110.9. NRCI-LTI-02-E-Must ben bre tzed fora lighting controls stem or for an Energy Management Control System EMCS), to be compliance. recognized for g ❑ Field Ins ector Lighting shall be controlled by a lighting control a system or energy management control system in accordance with §110.9. An Installation Certificate X NRCI-LTI-03-E- Must be submitted fare line -voltage track lighting integral current limiter, Orford supplementary overeurrent protection panel used to energize only line -voltage track lighting, to be recognized for compliance. ❑ Field Inspector ❑ X NRCI-LTI-04-E- Must he submitted for two interlocked systems serving an auditorium, a convention center, a conference room, a multipurpose room, or a theater to be recognized for compliance. ❑ Field Inspector F X NRCI-LTI-o5-E - Must be submitted for a Power Adjustment Factor (PAF) to be recognized for compliance. ❑ Field Inspector Track Lighting SupplementaryOvercurrent Protection Panel shall beinstalled ma accordance with Section 110.9 and Section 130.3. Additionally, an X NRCI-LTI-06-E - Must be submitted for additional wattage installed in a video conferencing studio to be recognized for compliance. Field Inspector Declaration of Required Certificates of Acceptance- Declare by checking all of the Certificates of Acceptance that will be. submitted. (Retain copies and verify forms are completed and signed.) YES NO Form/Title CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2013 STATE OF CAI IFORNIA - INDOOR LIGHTING - LIGHTING CONTROLS GIA ENERGY COMMISSION ISO,1 CENRCC L'1109E Ravised 06.13 ALIFORN X NRCA-LTI-02-E-Must besubmitted for occupancy sensors and alttomatic time switch controls. ❑ Field Inspector X NRCI I -03-E - Must be submitted for automatic daylight controls.. ❑ Field Inspector X NRCA-LTI-04-E- Must be submitted for demand responsive lighting controls. ❑ Field Inspector A. Mandomry Lighting Control Declaration Statements Indicate if the measure applies: CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2013 STATE OF CAI IFORNIA - INDOOR LIGHTING - LIGHTING CONTROLS GIA ENERGY COMMISSION ISO,1 CENRCC L'1109E Ravised 06.13 ALIFORN CERTIFICATE OF COMPLIANCE NRCC-LTI-02-E� Indoor Lighting - Lighting Controls (Page 1 of 5) Project Name: ADDITION FOR MAISIE JANE 77FMe Prepared: 8/29/2016 Accountable The NRCC-LTI-02-E shall be used to document all mandatory and prescriptive lighting controls that are applicable to the project. Efficiency Regulations in accordance with Section 110.9. A. Mandomry Lighting Control Declaration Statements Indicate if the measure applies: YES NO Control Requirements ® ❑ Lighting shall be controlled by self-contained lighting control devices which are certified to the Energy Commission according to the Title 20 Appliance Accountable Office Location Efficiency Regulations in accordance with Section 110.9. ❑ ® Lighting shall be controlled by a lighting control a system or energy management control system in accordance with §110.9. An Installation Certificate AREA(fe) Field inspector shall be submitted in accordance with Section 130.4(6). ❑ ® One or more Track Lighting Integral Current Limiters shall be installed which have been certified to the Energy Commission in accordance with §110.9 and E F 1 0.0. An Installation Additionally, an Installation Certificate shall be submitted in accordance with Section 130.4 b . 43 y, ( ) ❑ ®A Track Lighting SupplementaryOvercurrent Protection Panel shall beinstalled ma accordance with Section 110.9 and Section 130.3. Additionally, an - � OMe Signed: Installation Certificate shall be installed In accordance with Section 130,4(b), ® ❑ All lighting controls and equipment pshall comply with the applicable requirements in 4110.9 and shall be installed in accordance with the manufacturer's @ @ c v r; � 2 O instructions in accordance with Section 130.1.. ® ❑ All luminaires shall be functionally controlled with manually switched ON and OFF lighting controls in accordance with Section 130.1(a). Job z General lighting shall be separately controlled from all other lighting systems in an area. Floor and wall display, window display, case display, ornamental, ❑ ® and special effects lighting shall each be separately controlled on circuits that are 20 amps or less. When track lighting is used, general, display, D Identify office area In whkh ornamental, and special effects lighting shall each be separately controlled; in accordance with Section 130.0(a)4. ❑ ® The general lighting of any enclosed area 100 square feet or larger, with a connected lighting load that exceeds 0.5 watts per square foot shall meet the 3, 3 luminaire multi-level lighting control requirements in accordance with Section 130.1(b). ® ❑ All installed indoor lighting shall be equipped with controls that meet the applicable Shut -OFF control requirements In Section 130.1fc). ❑ 0 Lighting in all Daylit Zones shall be controlled in accordance with the requirements in Section 130. L(d) and daylit zones are shown on the plans. E] ® Lighting power in buildings larger than 10,000 square feet shall be capable of being automatically reduced in response to a Demand Responsive Signal in watts in this _ accordance with Section 130.1(). June 2013 Registration Number. Registration Ders" ime: HERS Provider: CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance S fATE OF CALIFORNIA INDOOR LIGHTING POWER ALLOWANCE CEC NILCQ LI 10I private Cara CALIFORNIA EI CERTIFICATE OF COMPLIANCE Cernflcate of Compliance- Indoor Lighting Power Allowance Project Draw. ADMON FOR MI JANE Date Prepared: 8/29/2016 STATE OF CALIFORNIA INDOOR LIGHTING Lz CEG4RCCirIa1F Ralned rlbn Ef_ CALIFORNIAENER?CY(OMMI SIGN .. CERTIFICATE OF COMPLIANCE - USER INSTRUCTIONS NRCC-LTI-01-E Indoor Lighting (Page 3 of 5) Pur Name: ADDITION FOR MAISIE JANE Dale Prepared; 8/29/2016 1 u Aseparate Lighting Schedule Must Be Filled Out for Conditioned and Unconditioned Spaces. Installed Lighting Power Listed on this Lighting Schedule is Only Fon CONDITIONED SPACE Q UNCONDITIONED SPACE A. INDOOR LIGHTING SCHEDULE and FIELD INSPECTION ENERGY CHECKLIST ❑The decoaIindoor ightingpower listeon this pageand on the next page includes all installed permanent and planned portable lighting systems. ❑ When complete Building Method is used for compliance, list each different type of luminaire on separate lines. ®When Area CategoryMeth d or Tailored Method is for compliance, list each different tYPa of luminaire by each different function area on separate lines. Also include track lighting in schedule and submit the track lighting compliance form LTG -SC when line -voltage track lighting is installed. B.I nstalled Portable Luminaires in Offices- Exception to Section 140.6 a p IJ u portable luminaires in offices As defined in 100.1. All other planned portable luminaires shall be documented on next age of This section shall be fiiledo out for ab min es 4 ❑ P ( ) P P page this compliance form. This section is used to determine if greater than 0.3 watts of portable lighting is planned for an office. ❑ K P B B P Y ❑ Fill out a separate line for each different office. Small offices that are typical (having the same general and portable fighting) may be grouped together. This allowance shall not be traded between offices having different lighting systems. Office Portable Luminaire Office Installed Portable luminaire Watts Per Square Accountable Office Location F Schedule Foot Watts AREA(fe) Field inspector A 8 C D E F G H I 1 - � OMe Signed: Standards Complying With' Installed Address: - n o c v r; � 2 O Lighting Control Schedule (✓all that aPPIY, or enter'E' if Exempted) w' °- 530-244-0202 Job z portable o watts If Fs;0.3, D Identify office area In whkh Complete Luminaire Descri tion P p -v u Complete Luminaire Description fie, 3 z 3, 3 luminaire L per enter zero; ExG these portable Inminalres P Type/ Description of Lighting g n - - LED under cabinet furniture mounted Watts er P Re = watts in this _ s uare 9 . RR r -'n II• a c 1 std cd Pass Fail - direct indirect / ) Wminairc ❑ ❑ office n foot ifF>0.3 ❑ ,'_ , w an n �, (Bx Q. {D/Q (F-0.3) Location in Building automatic time switch, ❑ El-❑ o a ca re '❑'.. o ca in n a ❑ ❑ El dimmer, automatic daylight, Units 0 Er W r- ❑ 5 at m fi ❑ ❑ LJ = eta ❑ ❑ ❑° ❑: ❑' ❑ N El o ❑. NEW WAREHOUSE INTEGRAL MOTION SENSOR 9 X E X E E E ❑I 999 Enter sum total of all pages into Enter sum total of all pages into Total installed portable luminaire watts that are greater than 0.3 watts per square foot per office: N RCC-LTI-01-E; Page 2 NRCC- LTI-01-E; Page 2 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance STATE OF CALIFORNIA INDOOR LIGHTING - LIGHTING CONTROLS CS, Pop in.eae IRa�rpaa oars CERTIFICATE OF COMPLIANCE STATE OF CALIFORNIA INDOOR LIGHTING CECaHRCC.1.1'-0'-E(Rev'sed0 CALIFORNIA kNERGY CO"d'JISSIO A tn•. c' CERTIFICATE OF COMPLIANCE- USER INSTRUCTIONS NRCC-LTI-01-E Indoor Lighting (Page 4 of 5) Pro Date Prearech 8 ect Name: ADDITION FOR MAISIE JANE P /29 / 2016 1 A separate Lighting Schedule Must Be Filled Out for Conditioned and Unconditioned Spaces. Installed Lighting Power Listed on this Lighting Schedule is Only For ® CONDITIONED SPACE ❑ UNCONDITIONED SPACE C. INDOOR LIGHTING SCHEDULE and FIELD INSPECTION ENERGY CHECKLIST - Luminaire Schedule Installed Watts s Location Fieldmserror r P A B C D E F G H (Page 3 of 5) AREA(fe) ALLOWED WATTS .4,990 How wattage was Date Prepared: 9/29/2016 Ncl p - 1.0 4,990 n 0 g Rzsponslblc Or,uper Sigra re: determined z ° m - � OMe Signed: Standards Complying With' 8/29/2016 Address: - n o c v r; � 2 O Lighting Control Schedule (✓all that aPPIY, or enter'E' if Exempted) w' °- 530-244-0202 Job m n A � C D o m Complete Luminaire Descri tion P p -v u a 8 i o 3 3 z _ `^ K L r Re E Le 31am fluorescent troffer, v m z or _ _ Type/ Description of Lighting g n - Primary, Function area in which ry Re = F32T8, one dimrrlable electronic ballast) m � . RR these luminaires are installed Pass Fail A LED HIGH BAY W/ MOTION SENSOR 111 ❑ ❑ 9Y999 #Aa NEW WAREHOUSE '!.❑ ❑ ,'_ , w an n �, Location in Building automatic time switch, ❑ El-❑ o a ca re '❑'.. o ca in n a ❑ ❑ El dimmer, automatic daylight, Units 0 Er W r- ❑ 5 at m fi ❑ ❑ LJ = eta ❑ ❑ ❑' ❑ N El o ❑. NEW WAREHOUSE INTEGRAL MOTION SENSOR 9 X E X E E E INSTALLED WATTS PAGE TOTAL: 999 Enter sum total of all pages into n 17171 N RCC-LTI-01-E; Page 2 A separate document must be filled out for Conditioned and Unconditioned Spaces. This page is used only for the following: ® CONDITIONEDSPACES ❑ UNCONDITIONED SPACES MANDATORY AND PRESCRIPTIVE INDOOR LIGHTING CONTROL SCHEDULE, PAF CALCULATION, and FIELD INSPECTION CHECKLIST CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Before an occupancy permit is granted for a newly constructed building or area, or anew lighting system serving a building, area, or site is operated for. June 2013 9 OMMISSION ' CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance S'rA'I'E OF CALIFORNIA INDOOR LIGHTING - LIGHTING CONTROLS CECNRGC.LTI-a2-E encedried 9N13 June 2013 S CALIFORNIA ENERGY COMMISSION yd NRCC-1-TI-021 CEO FIRCC-Lu 03-E PRIAER,106113 CERTIFICATE OF COMPLIANCE NRCC-LTI-02-E (Page 2 of 5) controls, and demand responsive controls. Indoor Lighting- Lighting Controls (Page 3 of 5) AREA(fe) ALLOWED WATTS .4,990 Protect Name: ADDITION FOR MAISIE JANE Date Prepared: 9/29/2016 Ncl p - 1.0 A separate document must be filled out for Conditioned and Unconditioned Spaces. This page is used only for the following: ® CONDITIONEDSPACES ❑ UNCONDITIONED SPACES MANDATORY AND PRESCRIPTIVE INDOOR LIGHTING CONTROL SCHEDULE, PAF CALCULATION, and FIELD INSPECTION CHECKLIST CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance Before an occupancy permit is granted for a newly constructed building or area, or anew lighting system serving a building, area, or site is operated for. ❑ ® normal use, indoor lighting controls serving the building,area, or site shall be certified as meeting the Acceptance Requirements for Code Compliance in IS310N CEO FIRCC-Lu 03-E PRIAER,106113 accordance with Section 13OAfa). The controls required to meet the Acceptance Requirements include automatic daylight controls, automatic shut -OFF r (Page 2 of 4) controls, and demand responsive controls. A separate document must be filled out for Conditioned and Unconditioned Spaces. This page is used only for the following: ® CONDITIONEDSPACES ❑ UNCONDITIONED SPACES MANDATORY AND PRESCRIPTIVE INDOOR LIGHTING CONTROL SCHEDULE, PAF CALCULATION, and FIELD INSPECTION CHECKLIST CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance A separate document must be filled out for conditioned and Unconditioned Spaces. This page is used only for the following: ® CONDITIONED SPACES ❑ UNCONDITIONED SPACES PAF Credit Calculation' 0 INDOOR LIGHTING POWER ALLOWANCE IS310N CEO FIRCC-Lu 03-E PRIAER,106113 NRCC- CTI -03-E r (Page 2 of 4) Certificate of Cornpiiance- Indoor Lighting Power Allowance - Project Name ADDITION FOR MAISIE JANE AREA(fe) ALLOWED WATTS .4,990 Location in Building Primary Function Area per Table 140.6-C Ncl p Fi 1.0 4,990 n 0 g Rzsponslblc Or,uper Sigra re: ria z ° m - � OMe Signed: Standards Complying With' 8/29/2016 Address: - n o c v r; � a Lighting Control Schedule (✓all that aPPIY, or enter'E' if Exempted) w' °- 530-244-0202 Job Of Chill A 8 C D E F G IH I 1 K L M N O Type/ Description of Lighting g Control (i.e.: occupancy sensor, #Aa w is, w ,'_ , w an n �, Location in Building automatic time switch, of o a ca re o o ca in n a dimmer, automatic daylight, Units 0 Er W a 5 at m fi = eta N NEW WAREHOUSE INTEGRAL MOTION SENSOR 9 X E X E E E I E n 17171 ❑ ❑1 ❑: ❑,, Registration Number. Registration fattymm. lune 2013 CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance A separate document must be filled out for conditioned and Unconditioned Spaces. This page is used only for the following: ® CONDITIONED SPACES ❑ UNCONDITIONED SPACES STATE OF CALIFORNIA 0 INDOOR LIGHTING POWER ALLOWANCE IS310N CEO FIRCC-Lu 03-E PRIAER,106113 NRCC- CTI -03-E CERTIFICATEOF COMPLIANCE (Page 2 of 4) Certificate of Cornpiiance- Indoor Lighting Power Allowance - Project Name ADDITION FOR MAISIE JANE .Total Watts. Enter Total Watts into section A, row 2(Above on this page)77 4,990 A A separate document must be filled out for conditioned and Unconditioned Spaces. This page is used only for the following: ® CONDITIONED SPACES ❑ UNCONDITIONED SPACES C-2 AREA CATEGORY METHOD GENERAL LIGHTING POWER ALLOWANCE ❑ Do not include portable lighting for offices. Portable lighting for offices shall be documented only in section B of NRCC-LTI-01-E ❑ Separately list lighting for each primary function area as defined in §100.1 of the Standards. 0 A B G C = D AREA CATEGORY (From §140.6 Table 140.6-C) WATTS PER(ft)X AREA(fe) ALLOWED WATTS .4,990 Location in Building Primary Function Area per Table 140.6-C NEWWAREHOUSE HIGH BAY -INDUSTRIAL WORK AREA 1.0 4,990 RuspnnslNe pullser Name: Rzsponslblc Or,uper Sigra re: CHRIS ABRAHAMSEN 7. C"'wery: OMe Signed: PACE ENGINEERING_ 8/29/2016 Address: - Lill.. 1730 SOUTH ST E012726 COStoopp: Erma: REDDING CA 96001 530-244-0202 Job Of Chill Registration Number. Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance HERS Provider: June 2013 HERS Provider: June 2013 NRCC-LTI-03-E (Page 3 of 4) TOTALS 4,990 4,990 Enter sum total Area Category allowed watts into section C-1 of NRCC-LTI-03-E(this compliance form) 4,990 WATTS A separate page must he filled out for Conditioned and Unconditioned Spaces. This page m only for: ® CONDITIONED spaces ❑ UIRCONDITIONEDspaces C-2 AREA CATEGORY METHOD Additional Lighting Wattage Allowance (from Table 140.6-C Footnotes) A B C' 0 E F G Primary Function Sq Ft or Linear Ft` Additional Watts Allowed Wattage Allowance (BisQ _-- - _-__-_ Descriptionis) and quantity of Special Luminaire Types in each Primary Function Area --- Total Design Watts' ALLOWED WATTS Smaller of D0,F 1 The energy features and performance specifications,materials,components, and manufactured devices for the building design or system design identified on this Certificate of Compliance confomt to the requirements of Title 24, Part l and Part 6 of the California Code of Regulations. 4, The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable Compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building perminfs) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at crcupan w RuspnnslNe pullser Name: Rzsponslblc Or,uper Sigra re: CHRIS ABRAHAMSEN 7. C"'wery: OMe Signed: PACE ENGINEERING_ 8/29/2016 Address: - Lill.. 1730 SOUTH ST E012726 COStoopp: Erma: REDDING CA 96001 530-244-0202 Job Of Chill TOTALS- Enter into TOTAL AREA CATEGORY METHOD ADDITIONAL ALLOWANCES -Section C-1 Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance INSTALLED WATTS PAGE TOTAL: 999 IF MULTIPLE PAGES ARE USED, ENTER SUM TOTAL OF ALL PAGES HERE: 1.§130.1(a)=Manual area controls;§330.0fb)=Multi Level, §130.1(cj=Auto Shut -Off, §130.1fd)=14andatary Daylight,§130.1fe)=Demand Responsive; §140.6(d)= Additional lighting controls installed to earn a PAF, §140.6/d) = Prescriptive Secondary Sidelit Daylight Controls. 2. Check Table 140.6-A for correct Factor. PAFs sholl not be traded between Conditioned and unconditioned spaces. As o condition to earn a AAF, on Installation Certificate is also required to be filled out, signed, and submitted. DOCUMENTATION AVTHOR'S DECLARATION STATEMENT - L Icerti ffiatthrs CanHiceto of Com liance documentation is accurate and complete. 0-11atbnfutntleame: oocumemaeonlrul-agoam,e t JOSH SCOTT aad">y't simwnr. PACE ENGINEERING 9/29/2016 CEA! HERS Cer[fwron ldent4¢at n n Amble: Address: A 1 n. I 17 SOUTH ST N/A 30 ewittpteia�p: Pnnde: REDDING,CA96001 530_-2_44,0202 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The Information provided on this Certificate of Complia nce is true and correct. 2. 1 am eligible under Division 3 of the Business and Pro Fess'ions Code to accept responsibility for tie building resign or system design identified on this Certificate Of Compliance (responsible designer). The energy features and erformances specifications, materials components, and manufactured devices for the bull din design stem design identified on this Certificate of 3 gY P P P g g Y a Compliance conform Lathe requirements of Title 24, Part 1 and Part 6 of the Calirnrnia Code of Regulations. 4. The building design features or system design features Identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance docort or worksheets calculations lads and specifications submitted to the enforcements enc fora cast l with this building permit lication. n .P P agency PP gP PP I will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permitls) Issued for the building, and made aver liable to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. CHRIS blenesrgnertlamr. PflSpone 6l n :g Slgnature:� /J ,ry �,,. CHRIS ABRAHAMSEN ORR., --- Odie sexed: PACE ENGINEERING___ 8/29 2016 Address': u'la : 1730 SOUTH ST E012726 issrSiI prone: _REDDING, CA 96001 ,530244-0202' Registration Number, Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance STATE OF CALIFORNIA INDOOR LIGHTING POWER ALLOWANCE; CBC-NIAC LTI-0SE(Revis ed Nola HERS Provider: lune 2013 GALIFORNIAENERGYCOMMIS810N . CERTIFICATE OF COMPHANCE NRCC-LTI-03-E Certlf¢n[e of Campllance - Indoor Lighting Power Allowance (Page 4 of 4) Protect Name ADDITION FOR MAISIE JANE Cate Prepared &/2912016 -- - - --- e linear feet o for additional allowance for white board or chalkboard. All other additional Area Category allowances shall use watts per square foot. 1. Us I ee only g y p q 2. Additional watts are available only when allowed according to the footnotes on bottom of Table 146-C, which include: Specialized task work; Ornamental lighting;. Precision commercial and industrial work; Per linear foot of white board or chalk board; Accent display and feature lighting; and Videoconferencin Studio lighting.. P n P Y B 3. Luminaire classification and wattage shall be determined in accordance with §130.0(c) of the Standards. DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Com ellance documentation is accurate and complete. 0-illente ali,Amlm, name: Domr�marp Avtnar SRmture. JOSH SCOTT A °m,p+mr--nMure lhte: PACE ENGINEERING 8 29 2016 Ad9rcs CEA/HEM certification Identlfiat (f epllaalc) 1730500TH ST N/A elty/slatejl¢ 'hons: REDDING CA 96001 530-244-0202 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of Callfornla: 1. The information provided on this Certificate of Complia nce is tore and correct. 2, lam eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 1 The energy features and performance specifications,materials,components, and manufactured devices for the building design or system design identified on this Certificate of Compliance confomt to the requirements of Title 24, Part l and Part 6 of the California Code of Regulations. 4, The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable Compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building perminfs) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at crcupan w RuspnnslNe pullser Name: Rzsponslblc Or,uper Sigra re: CHRIS ABRAHAMSEN 7. C"'wery: OMe Signed: PACE ENGINEERING_ 8/29/2016 Address: - Lill.. 1730 SOUTH ST E012726 COStoopp: Erma: REDDING CA 96001 530-244-0202 HERS Provider: Registration Number: Registration Date/Timm. June 2013 CA Building Energy Efficiency Standards- 2013 Nonree(ssi�idential Compliance PERMIT #V-*- ^7r BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR CODE COMPLIANCE DATE � BY HERS Provider: June 2013 REVIEW - FOR CODE COMPLIANCE NOV 10 2016 INTERVVEST CONSULTING GROUP RZtII Or.. t N� iF- v F tu - R J F tT �pf , 1 _ I V n � Ul 6T �S m S Y N d t� �r aJY LUyy srL O LU, ^ V DOM s �O�C�i/���� BOOM �rHOM Dim CANS Job Of Chill --. - T-�_ _..1 I I I�f 1 1 f -1-T I FF 1- - I Tu i I I III VIII �'I� STATE OF CALIFORNIA OUTDOOR LIGHTING CEC-NRCCLTO-0t£ (Revised 06113) CALIFORNIA ENERGY COMMISSION ° CERTIFICATE OF COMPLIANCE NRCC-LTO-OS-E Outdoor Lighting (Page 1 of 3) Pmlect Name: ADDITION FOR MAISIE JANE Date Prepared: 3/29120,16 Project Address:T"al Illuminated Hardscape Area 3764 HEGAN LN, CHICO CA 95928 18,500 SO ET General Information Phase of Construction: ❑ New Construction E Addition ❑ Alteration Outdoor lighting Zone ❑OLZ-1 EOLZ-2 EI OLZ-3 0OLZ-4 (OLZ) The OLZ is: ® Default in accordance with 10-114, or ❑ Amended by the AHJ DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete nnwment#nn AAho, Name: DacumenefibnA tb Slpataure JOSH SCOTT enmparm Sllesmoe Date'. PACE ENGINEERING 8/29/2016 Adores (EA{ HERS CouffiratRu, Identification (if applcabla. 1730 SOUTH ST N/A , Cit {Stat P ZI : Phone: BEDDING CA 96001 530-244-0202 RESPONSIBLE PERSON'S DECLARATION STATEMENT !certify the following under penaltyof perjury, ry.0nder the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy featu res a Ad performance specifications, materiaIs, core porests, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance a re consistent with the information Provided on other applicable compliance documents worksheets, calculations, plans andspecifications submitted to the enforcement agency for approval with this building permit application, 5. I will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building periods) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be Included with the documentation the builder provides to the building owner at Resp h: De.g er Nome: Relp.111W re,11,111 51neture CHRISABRAHAMSEN <� issrpsr, o i ss h PACE ENGINEERING 8/29/2016 Jet"r LI 1730 SOUTH ST E012726 aiwsatenip: phone: REDDING,CA 96001 530-244-0202 LIGHTING COMPLIANCE DOCUMENTS (check boxfor each document included) For detailed instructions on the use of thus and all Energy Efficiency Standards compliance documents, refer to the Nonresidential Manual published by the California Energy Commission, ® NRCC-LTORE-E Certificate of Compliance ® NRCC-LTO-02-E Outdoor Lighting Controls Certificate of Compliance fJ NRCC-LTO-03-E Outdoor Lighting Power Allowance Certificate of Compliance CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance STATE OF CALIFORNIA OUTDOOR LIGHTING CONTROLS CERTIFICATE OF COMPLIANCE _ , - _ _ ----- - _ _ _ NRCC LTO 01.E Outdoor Lighting (Page 3 of 3) WojecCName:ADpInON mR MAISIE IANE Date Prepared 8/29/2016 A. OUTDOOR LIGHTING SCHEDULE and FIELD INSPECTION ENERGY CHECKLIST Luminaire Schedule Installed Watts Location Cutoff Field Inspecto A B C D E F G H i Name or Joan Tag Complete Luminaire Description 3 g �, a How wattage was determined 3 -' B _ R j '_ - is= g Primary Function area in which these luminaires are installed in n w " is _ q, (r„ 3 0 es F Y es B LED EXTERIOR WALL PACK 70 ❑® 3 210 BUILDING LIGHTING CHRIS ABRAHAMSEN --'.....-'---- -"--" : ❑ , .❑, PACE ENGINEERING 8/29/2016 - -_ _ Address Li R -c 1730 SOUTH ST E012726 11 El 530-244-0202 Of motion sensor, photocontrol, outdoor 9w ,�- ❑ ❑ use i ❑ :Ell, Location and Application of astronomical time -switch control, ❑ ❑ o 0 E, P v, ca ca ❑ ❑.t v El r0 n - centrallzed time -based zone lighting Units `w n `n ❑ El ' G V ti hElE ❑ElL)❑ ar TYPE BLIGHTING CONTROL PANEL 1 E X X E E E ❑ ❑;; ❑ . ❑❑ ❑ IEl" ❑ LOT - •., ❑ ❑ i Cl .. i� ❑ ❑ I Q ,f] ❑ ❑` El _ _- - - D El ❑:, EE D INSTALLED WATTS PAGE TOTAL: 210 Enter sum total of a 11 pages into NRCC-LTO- 01-E; Page 2 CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance June 2013 STATE OF CALIFORNIA D-rial to _ AW.' came: OUTDOOR LIGHTING CONTROLS JOSH SCOTT CECOI LTO 02 ElRe4s A Callan_ _ _--------- - - ------ CAu_FORnIIn_ENeacvcornwlssloN •_ slgnawreoara CERTIFICATE OF COMPLIANCE NRCC-LTO ObE _ Address: "" Outdoor Lighting Controls (Page 3 of 3) DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1, i certify that this Certificate of Com liance documentation is accurate and complete. D-rial to _ AW.' came: br, m ....on.. iher S gne Y, JOSH SCOTT Lighting Power Allowed for Specific Application for Ornamental -NRCC-LTO-02-E + - CPmpaen slgnawreoara PACE ENGINEERING _ _ _ _g/2912016 __ -"""_"__"_ _ Address: "" CE4r HERS Certification ltl Ifl [on if apPllcbl 1: 1730 SOUTH ST "Phone 'unmaA.am: a REDDING CA 96001 530-244-0202 RESPONSIBLE PERSON'S DECLARATION STATEMENT Icertify the following under peva try of perjury, under the laws of the State ofCalifornia: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performancespecifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permits) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this CertFficate of Compliance Is required to be Included with the documentation the builder provides to the building owner at occupancy. Responilble Dezigner Hare Re<pnrei41e Ce5igner Signa[ure:� // /}ry f� CHRIS ABRAHAMSEN --'.....-'---- -"--" Dote sarrea: PACE ENGINEERING 8/29/2016 - -_ _ Address Li R -c 1730 SOUTH ST E012726 CLLy/trate@P PM1 530-244-0202 CA B-,lding Energy Efficiency Standards - 2013 Nonresidential Compliance June 2013 CEC-ORCC-LTO 02£ Revised 06!131 CERTIFICATE OF COMPLIANCE Outdoor Lighting Controls STATE OP CALIFORNIA OUTDOOR LIGHTING CCC-NRCC4_TO-01£ (RAI 06113) CALIFORNIA ENERGY COMMISSION 0 CERTIFICATE OF COMPLIANCE NRCC-LTO-01- Outdoor Lighting (Page 2 of 3) Project Name: ADDRION FOR MAISIE JANE Date Prepared: 8/29/2016 Summary of Allowed Outdoor Lighting Power watts 1. Lighting Power Allowed for General Hardscape- NRCGLTOI + 1,680 2. Lighting Power Allowed for Specific Application per Unit Length -NRCC-LTO-02-E + - 3, Lighting Power Allowed for Specific Application for Ornamental -NRCC-LTO-02-E + - 4. Lighting Power Allowed for Specific Application per Square root -NRCC-LTO-02-E + - 5, Sum Total of ALLOWED Outdoor Lighting Power = 1,680 Outdoor Lighting Controls Complies ONLY if Installed a Allowed 6, INSTALLED Outdoor lighting from NRCC-LTI-01-E, page 4 210 Declaration of Required Installation Certificates- Declare by checking all Installation Certificates that will be submitted. (Retain copies and verify forms are completed and signed.) ❑ NRCI-LTO-01-E- Must be submitted for all buildings _Tff Field Inspector ® NRCI-LTO-02-E - Must be submitted for a lighting controls stem or for an El Inspector Energy Management Control System (EMCs), to be recognized for compliance. CC -I TO -02-E fRai sed 001131 EC -NRC Declaration of Required Certificates of Acceptance -Declare by checking all of the Certificates of Acceptance that will be submitted. (Retain copies and verify forms are completed and signed.) ® NRCA-LTO-02-E - Must be submitted for outdoor lighting controls. I ❑ Field Inspector Schedule of luminaires exempt from the outdoor lighting power requirements in §140.7 Name or Symbol I Description of exempt luminaire in accordance with the exemptions I Schedule of luminaires exempt from the cutoff requirements in §130.2(b) Name or Svmbol I Description of exempt luminaire in accordance with the exemptions � Schedule of luminaires exempt from the outdoor fighting control requirements in §130.2(c) (Name or Symh01 1 DESCHphonofexemptIuEDinaireinaccord aDOE wit ITtheexeonDOons June 2013 CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance lune 2013 2. Additional Specific "use it or lose it" Lighting Power Allowances listed in each of these cells shall be identical to total allowed STATE OF CALIFORNIA INot OUTDOOR LIGHTING CONTROLS CALIFORNIA ENFROYCOMAIISSION " CC -I TO -02-E fRai sed 001131 EC -NRC NRCC-LTO-02-E CERTIFICATE OF COMPLIANCE (Page 1 of 3) Outdoor Lighting Controls Mandatory Outdoor lighting Control Declaration Statements Check all that apply: E Lighting shall be controlled by self-contained lighting control devices which are certified to the Energy Commission according to the Title 20 Appliance Efficiency Regulations in accordance with §110.9. ❑ Lighting shall be controlled by a lighting control a system or energy management control system in accordance with §110.9. An Installation Certificate shall be submitted in accordance with §130.4(6). E All lighting controls and equipment shall comply with the applicable requirements in §110.9 and shall be installed in accordance with the manufacturer's instructions in accordance with§130.1 ❑ Part -Night Outdoor Lighting Controls, as defined in Section 100.1, shall meet the requirements in Section 110.9(6)5 ❑ All outdoor incandescent luminaires rated over 100 watts, determined in accordance with Section 130.0(c),.shalt be controlled by a motion sensor. ❑ All outdoor luminaires rated for use with lamps greater than 150 lamp watts, determined in accordance with Section 130.0(c), shall comply with Backlight, Uptight, and Glare (collectively referred to as "BUG") in accordance with Section 130.2(b) E All installed outdoor lighting shall be controlled by a photocontrol or outdoor astronomical time -switch control in accordance with Section 130.2(c)1 ® All installed outdoor fighting shall be circuited and independently controlled from other electrical loads by an automatic scheduling control in accordance with Section 130.2(c)2 ❑ All installed outdoor lighting, where the bottom of the tuminaire is mounted 24 feet or less above the ground, shall be controlled with automatic lighting controls in accordance with Section 130.2(c)3 ❑ For Outdoor Sales Frontage, Outdoor Sales Lots, and Outdoor Sales Canopies lighting, an automatic lighting control in accordance with Section 130.2(c)4 ❑ For Building Facade, Ornamental Hardscape and Outdoor Dining lighting, an automatic lighting control in accordance with Section 130.2(c)S ❑ Before an occupancy permit is granted for a newly constructed building or area, ora new lighting system serving a building, area, or site is operated for normal use, indoor lighting controls serving the building,area, or site shall be certified as meeting the Acceptance Requirements for Code Compliance in accordance with §130.4.(a). Outdoor lighting controls shall comply with the applicable requirements of Section 130.2(c) and Reference Nonresidential Appendix NA7.8 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance STATE OF CALIFORNIA OUTDOOR LIGHTING POWER ALLOWANCES CEC_NRCCLT003-EFEaead06a3_-___ ___________ CERTIFICATE OF COMPLIANCE Outdoor Lighting Power Allowances NRCC-LTO-02-E MANDATORY OUTDOOR LIGHTING CONTROL SCHEDULE and FIELD INSPECTION CHECKLIST CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance 2. Additional Specific "use it or lose it" Lighting Power Allowances listed in each of these cells shall be identical to total allowed ti t INot OUTDOOR LIGHTING POWER ALLOWANCES MMISSION IS _, NRCC LTO -03 E Outdoor Lighting Control Schedule Standards Complying With z D m a 337.5 all that apply, or enter'E' if Exempted) c: v a f 16 16 - A B C D E F G H I N O Type/ Description of Lighting Control (i.e. Dab Ob/2111106 .100!9 SFIOYIMI DIOM11 CWJS J Bowe E25 Of motion sensor, photocontrol, outdoor 9w ,�- save use Location and Application of astronomical time -switch control, of o 0 E, P v, ca ca as v Lumina¢es being controlled n - centrallzed time -based zone lighting Units `w n `n control) V ti ar TYPE BLIGHTING CONTROL PANEL 1 E X X E E E ❑ ❑;; ❑ IEl" ❑ ❑ ❑` _ _- - - -. ❑ ❑:, ❑ ❑ ❑ ❑. ❑ ❑= ❑d! June 2013 CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance 2. Additional Specific "use it or lose it" Lighting Power Allowances listed in each of these cells shall be identical to total allowed STATE OF CALIFORNIA INot OUTDOOR LIGHTING POWER ALLOWANCES MMISSION CEONRCC-130-03£faivieelffill NRCC LTO -03 E LWA (Dx E) TWA (Watts) C+F+G I CERTIFICATE OF COMPLIANCE A. OUTDOOR LIGHTING POWER ALLOWANCE SUMMARY 1. General Hardscape Lighting Power Allowance(Sitetotal from Section B of NRCC-LTO-03-E) 1,680 2. Additional Specific "use it or lose it" Lighting Power Allowances listed in each of these cells shall be identical to total allowed watts determined in Section Gl to 17-4 of NRCC-LTI-04-E. PERAPPLICANON SALES FRON I AGE ORNAMENTAL LIGII rINO PERSPFCIFlCAREA from Section C-1 from Section C-2 from Section C-3 from Section C-4. 3. Total Allowed Outdoor Lighting Wattage (add rows 1 and 2) 1,680 B. GENERAL HARDSCAPE LIGHTING POWER ALLOWANCE FROM TABLE 140.7-A Area Wattage Allowance (AWAi Linear Wattage Allowance EWA Initial Wattage Allowance Total General Hardscape (TWA) Lighting Allowance A B C D E F G H Illuminated AWA per Hardscape Area SquarepDot me Parlter Lengind fPAper AWA(Ax B) General Hardscape Ungar Foot LWA (Dx E) TWA (Watts) C+F+G 18,500 .045 832.5 750 .45 337.5 510 1680 '� VA �-u 3 f 16 16 - S LU O Dab Ob/2111106 .100!9 SFIOYIMI DIOM11 CWJS J Bowe E25 Of TOTAL 1,680 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2013 NRCC-LTO-03-E Sum total allowance per square foot of specific area on the site: DOCUMENTATION AUT'HOR'S DECLARATION STATEMENT 1. I certdy that this Certificate of Compliance documentation is accurate and complete. DocumsnWtwn Authorsirm Domrn -111 o,Author S111101e (•i JOSH SCOTT af~' company- sllrlrol nate. PACE ENGINEERING 8 29 2016 Adores: ¢A/ergs ee<nncan cot 'I<mmn;aapplka4lel: 1730 SOUTH 5T - NIA ayanmwzlp: Phone. REDDING CA 96001 530_244-0202 RESPONSIBLE PERSON'S DECLARATION STATEMENT certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certlflcate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calcu ladons, plans and specifications sub nfired to the enforcement agency for approval with this building permit application. 5. (will ensure that a com pietist signed copy of this Certificate of Compliance she 11 be, made available with the building permits)issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Respoml61e ctu,nar Name: fan,aralhle D"e¢ner spinner, 11 _ CHRIS ABRAHAMSEN cuaRnie, Win slpnxd! PACE ENGINEERING 8/29/2016 Add se" a ..: 1730 SOUTH ST E012726 cry/sue,17,: -- phare: - REDDING, CA 96001 530-244-0202 June 2013 CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance tI I^ o �T., i I I I I� 111 June 2013 PERMIT #k _ �((u--( 70 BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR / CODE COMPLIANCE DATL._-1 (*lt;� ( Y, Ev ° c cav REVIEWED FOR CODE COMPLIANCE KN 10 2016 INTERWEST CONSULTING GROUP w UMSIMS BY I N� ry �r�J V V O 7-{-1 3 -1 0 '� VA �-u 3 f 16 16 - S LU O Dab Ob/2111106 .100!9 SFIOYIMI DIOM11 CWJS J Bowe E25 Of ROOG�S P - O - LQ o� DAYTON ROAD SITE.h, :. r VERIFY SCALE A BAR IS ONE INCH ON c ORIGINAL DRAWING o O IF NOT ONE INCH ON THIS SHEET, ADJUST SCALES ACCORDINGLY — J L - - I—x—x—x—x—x x x x z. x x x ." x x x x x x x. x x x x x z. x x x� x-. APN 039-080-092 x .PROVIDE MINIMUM 5' m CLEAR BETWEEN STORM x DRAIN AND GAS FACILITIES x �2 i 3 x r----- - �-----------------=------------------- p p NOTE: L------------------------------------------------------ -- INSTALL TEE FITTING AS NECESSARY FOR x 5' (MIN.) x CONNECTIONS FROM ONSITE STORM DRAIN -- -- -- — - -__ PIPING 70 STORM DRAIN LEACH TRENCH. NOTE: A MINIMUM VERTICAL SEPARATION o OF 5 FEET IS REQUIRED FROM THE BOTTOM OF. THE LEACH TRENCH TO GROUND WATER x w x FINISH J GRADE X / STORM DRAIN CONSTRUCTION NOTES CLASS 2 AGGREGATE BASE w PROPOSED RELATIVE COMPACTED TO 957 x x BUILDING COMPACTION ❑1 INSTALL 1110 LF STORM DRAIN LEACH PER DETAIL,. CONTRACTOR. SHALL ' w z - INSTALL 12"x6 TEE FITTINGS AT POINTS OF CONNECTION TO GUTTER T PIPING �-nt�' y r ,.----- -,� ;L 12" DIA. DUAL WALL HDPE i PIPE WITH AA HTO CLASS II x - x ❑2 INSTALL 12" x6"REDUCER'AT LEACH TRENCH, 6" DAM SOLID WALL HDPE _; PERFORATIONS CENTERED IN EX. SEPTIC TANK / PIPE WITH FITTINGS AND COUPLINGS AS NEEDED AND BUTTE COUNTY 2 "I" TRENCH, S=0.00 - GEOTEXTILE FABRIC x - ) CONTRACTOR SHALL FIELD VERIFY THE STD. S-22 AND S-23 FLUSHING HOLE WITH CONCRETE COLLAR AT FINISH OVERLAP 12" AT EDGES x _ I CLASS 1 PERMEABLE TI STORM DRAIN LEACH TRENCH IS A MINIMUM GRADE y 100' AWAY FROM THE EXISTING WELL L_ _-� MATERIAL, TYPE B, PER 3 INSTALL 12'x6"REDUCER AT LEACH TRENCH 6" DIAM SOLID L ,dI- i>T-!- SECTION 68-2.02F(2) - x ❑ WALL HDPE r--------� ------ -----------------------.--- - ---------- PIPE WITH FITTINGS AND COUPLINGS AS NEEDED AND BUTTE COUNTY SC OF THE STATE STD. AR FY BOTTOM AND I\ / STD. -S-22. ANDS -23. FLUSHING HOLE WITH CONCRETE: COLLAR AT FINISH SIDES OF TRENCH 5' - SPECIFICATIONS X I GRADE SEE BUTTE COUNTY STD. S-38 FOR ADDITIONAL INFORMATION - x I I I STORM DRAIN LEACH TRENCH DETAIL EXISTING i EXISTING x No SCALE BUILDING BUILDING / I R=100' I I I I � x I i x ----------------------- - -- -- - -� * EXISTING ROOF CANOPY I x \ I I I EX WELL \ x x GENERAL NOTES x 1.. LOCATIONS - AND _ DEPhISOFEXISTING-UTILITIESSHOWNONTHESEPLANS.AREAPPROXIMATE: THE CONTRACTOR SHALL -Z ` x VERIFY EXISTENCE,. LOCATION AND DEPTH OF ALL UTILITIES PRIOR TO ORDERING MATERIALS: OR BEGINNING \ EXISTING CONSTRUCTION. THE CONTRACTOR. SHALL CALL UNDERGROUND SERVICE ALERT (USA). AT 800-227-2600 AT LEAST 3 BUILDING\ I DAYS PRIOR TO CONSTRUCTION. x 2. ALL CONSTRUCTION SHALL CONFORM TO THE STANDARDS. AND SPECIFICATIONS OF THE COUNTY OF BUTTE ON FILE IN THE % \ I OFFICE OF THE DIRECTOR OF PUBLIC WORKS, BUTTE COUNTY, CALIFORNIA.. - x \ 3. AC IS DEFINED AS TYPE " B ASPHALT CONCRETE 3/4 MAXIMUM GRADING. x 4. AB IS DEFINED AS CLASS'2 AGGREGATE BASE 3/4" MAXIMUM MEDIUM GRADING. x \\ r p - - - - -----`---------------------------- ,Q x 5. CALL BUTTE COUNTY DEPARTMENT OF PUBLIC WORKS AT 538-7681 TO SCHEDULE INSPECTION AT LEAST 24 HOURS PRIOR 'I - - -- ---- --- --- --- - \ TO CONSTRUCTION. x EXISTING STORM DRAIN J \ LEACH TRENCH (PER \. x PLANS) - t d cs :LIMIT OF':d(', ex LEACHFlELD 10IG '1 i f/ FREE AREA -biw9 Of CBUILDINGS SHOULD OCCUR AS PART OF THE SITE DEVELOPMENT. ARE FOUND. - Designed Approved - .Drawing No. _ KLD PREPARED FOR: RAR STORM DRAIN LEACH TRENCH PLAN 1 OF 1 Drawn /410-0D. ROLLS ANDERSON &ROLLS /� CAD DateG I N N O CONSTRUCTION, I N C. CIVIL ENGINEERS A.P. N Q Q �% Job No. Checked PWR OCTOBER 2016 115 YELLOWSTONE DRIVE CHICO, CALIFORNIA 95973-5811 TELEPHONE 530-8951422 O 03 080 0"` 16144 - - - — - - -- - _ --- `- 17 IT � II .,. ,., I i ,._ .i I �. t T �Ii III II rlil��I L III 9i�1 x •'S Q(X()FESS/Q STORM DRAIN NOTE: : THE PROPOSED STORM DRAIN LEACH TRENCH SYSTEM HAS BEEN SITE PLAN NOTE: NO FIELD SURVEYING OR OTHER MEASUREMENTS HAVE BEEN - � ' �• Do ~'� PERFORMED IN CREATION "� L �� � DESIGNED TO ACCOMODATE THE 10 -YEAR STORM RETURN PERIOD PER THE OF THIS SITE PLAN. SHOWN - l'p BUTTE COUNTY STANDARDS. LARGER STORM EVENTS WILL FILL THE INFORMATION IS BASED ON PLAN INFORMATION AS SHOWN ON THE y LEACH TRENCH SYSTEM AND. ADDITIONAL STORM WATER WILL NOT BE SITE PLAN PREPARED BY GARY HAWKINS ARCHITECT DATED m ABLE TO ENTER THE SYSTEM. GUTTER DOWNSPOUTS DIRECTING SEPTEMBER, 2016. THE CONTRACTOR SHALL FIELD VERIFY THE d Na 66358 a WATER TO THE LEACH TRENCH SHOULD BE CONNECTED WITH AN AIR LOCATION OF EXISTING FEATURES AND THE PROPOSED IMPROVEMENTS ' GAP TO ALLOW EXCESS STORM WATER TO EXIT THE GUTTER SYSTEM. PRIOR TO BEGINNING CONSTRUCTION OR ORDERING MATERIALS. THE * CIw- .a# SITE GRADING TO DIRECT EXCESS STORM WATER AWAY FROM CONTRACTOR SHALL NOTIFY THE ENGINEER IF ANY DISCREPANCIES -biw9 Of CBUILDINGS SHOULD OCCUR AS PART OF THE SITE DEVELOPMENT. ARE FOUND. - Designed Approved - .Drawing No. _ KLD PREPARED FOR: RAR STORM DRAIN LEACH TRENCH PLAN 1 OF 1 Drawn /410-0D. ROLLS ANDERSON &ROLLS /� CAD DateG I N N O CONSTRUCTION, I N C. CIVIL ENGINEERS A.P. N Q Q �% Job No. Checked PWR OCTOBER 2016 115 YELLOWSTONE DRIVE CHICO, CALIFORNIA 95973-5811 TELEPHONE 530-8951422 O 03 080 0"` 16144 - - - — - - -- - _ --- `- 17 IT � II .,. ,., I i ,._ .i I �. t T �Ii III II rlil��I L III 9i�1 � ._ L.�L_ � l l _ IL i .. I I 4 i l ISI ��J� til .� 1` 1� i �t �\ y