HomeMy WebLinkAboutB16-1926 028-360-013Department of Development Services Tim Snellings, Director Pete Calarco, Assistant Director 7 County Center Drive T: 530.538.7601 Buttecounty.net/dds Oroville, California 95965 F: 530.538.7785 Building Permit Checklist Name: DOVBUSH, YURIY & YELENA Location: 227 CULET RANCH RD, OROVILLE Assessor's Parcel Number: 028-360-013 Permit Number: B.16-1926 X 1. 3 copies site plan k 2. 3 sets building plans 3. 1 set energy calcs (if applicable) 4. 1 set truss calcs (if applicable) 5. 1 set structural calcs (if applicable) 6. Intake Packet a. signed permit application -X b. owner builder (if applicable) c. notice to builders d. fee summary e. fire handout f. NPDES form g. data sheet ,z h. PW Notification for 26-12 i. Hazardous Material Form (commercial) �j. Accessibility Worksheet (commercial) k. Plan Check Sq Ftg Verification 7. Flood Certificates (if applicable) 8. 9. 10. Completed by: ✓/ Date: 9 / % Butte County Fire Department Fire Prevention Bureau Residential Building Requirements 176 Nelson Ave, Oroville, CA 95965 530.538.7888, 530.538.2105 Fax 530.538.6226 Inspection Line Permit Number: B16-1926 Location: 227 CULET RANCH RD Parcel Number: 028-360-013 Owner Name: DOVBUSH, YURIY & YELENA Description: Date: 9/1/2016 By: JMD Sub Type: SFD-CUSTOM/MODEL Phone: To meet the requirements of Government Code section 51182, Butte County Fire department requires a pre -construction inspection to provide the below building and site requirements to the property owner. Your property is located within the Butte County Fire Departments response area and must meet the below requirements: ❑ Public Resources Code 4290 (emergency access, signing/addressing, fuel modification standards) ❑ Public Resources Code 4291 (defensible space) ❑ California Fire Code LPG tank protection ❑ Butte County Improvement Standards Requirements prior to scheduling the pre inspection: Full plan submittal to Butte County Development Services Building Division To request an inspection call 530.538.6226; this is Fire Prevention Bureau's recorded inspection line; you will need the information at the top of this page. Inspection request that come through any other phone numbers will cause a delay in processing your permit. For the pre inspections, the property owner or authorized agent (contractor) is required to meet the inspector at the construction site. I have read and understand the above pre inspection requirements. Signature: Q Date: 912016 Department of Development Services Tim Snellings, Director Pete Calarco, Assistant Director 7 County Center Drive T: 530.538.7601 Buttecounty.net/dds Oroville, California 95965 F: 530.538.7785 T'�• +DEVELOPMENT SERVICES DOVBUSH, YURIY & YELENA RE: 028-360-013 Permit No: B16-1926 To' meet the requirements of Butte County Code Section 26-12 (available on line at ? : htip://municipalcodes.lexisnexis.com/codes/butteco ), one or more of the following may be required before a building permit can be issued for the above referenced project. The construction of curbs, gutters, sidewalks or walkways, public roads, proper access from public roads, and drainage facilities; Dedication of any necessary rights of way; and For commercial or industrial uses or for multiple living uses having three (3) or more living units per 1 parcel, the construction of an enclosure for containers used to hold solid waste and/or recyclable materials for collection. ' Requirements prior to issuance of building permit: Submit sufficient information to the Land Development Division of the Public Works Department, 7 J:'. County Center Drive, Oroville, CA 95965, that demonstrates compliance with County Code Section 26 -12. If construction plans and/or engineering analysis.are required, submit information in duplicate in accordance with County Improvement Standards (available on line at moo•//www buftecounty net/r)ublicworks/divisions/landdevelopment/impstd html) with a minimum plan k..:; . checking deposit of $690.40. Important Note: If improvements in compliance with County Code Section 26 12 are required, any construction, plans and/or engineering analysis must be reviewed and approved by the Land Development Division of the Public Works Department prior to construction of the improvements and the required improvements must be constructed, bonded, or guaranteed with a deposit of an in lieu fee prior to issuance of this building permit. The process can require significant time and must be completed prior to issuance of the building permit. If you have any questions, please contact the Land Development Division at -(530) 538 7266, Monday through Friday, 8:00 a.m. to 4:00 p.m. I have read and understand the above requirements: Signature: QC ooeL"W— Date: 9/1/2016 DEVELOPMENT SERVICES Department of Development Services Tim Snellings, Director Pete Calarco, Assistant Director 7 County Center Drive T: 530.538.7601 Buttecounty.net/dds Oroville, California 95965 F: 530.538.7785 PERMIT APPLICATION DATA SHEET Reference Number: B16-1926 Date: 9/1/2016 Location: 227 CULET RANCH RD By: JMD Parcel Number: 028-360-013 Sub Type: SFD-CUSTOM/MODEL Owner Name: DOVBUSH, YURIY & YELENA Phone: 5035510519 Description: REPL SFD LOG HOME (1168) COV (320) OPEN (270) The above permit application has the following Clearances required prior to permit issuance. Please contact each department indicated below regarding specific requirements pertaining to your permit application. YES SEWER DISTRICTS ❑ Thermalito Irrigation District, 410 Grand Avenue, Oroville CA 95965 — 530.533.0740 ❑ LOAPUD, 1960 Elgin Street, Oroville CA 95966 — 530.533.2000 ❑ City of Chico, PO Box 3420, 411 Main Street, Chico CA 95927 — 530.879.6700 PARKS & RECREATION DISTRICTS (form will be available after plans have been previewed by building department) ❑ Chico Area Recreation District, 545 Vallombrosa, Chico CA 95926 — 530.895.4711 ❑ Durham Park & Recreation District, 9447 Midway, Durham CA 95938 — 530.345.1921 ❑ Feather River Recreaction & Park District, 1875 Feather River Blvd, Oroville CA 95965 — 530.533.2011 ❑ Paradise Parks & Recreation, 6626 Skyway Road, Paradise CA 95969 — 530.872.6393 SCHOOL DISTRICTS (form will be available after plans have been reviewed by building` department) ❑ Biggs Unified School District, 300 B Street, Biggs CA 95917 — 530.868.1281 ❑ Chico Unified School District, 1163 East 7th Street, Chico CA 95926 — 530.891.3006 ❑ Durham Unified School District, 4920 Putney Drive, Durham CA 95938 — 530.895.4675 ❑ Gridley School District, 429 Magnolia, Gridley CA 95948 — 530.846.4723 ❑ Marysville School District, 1919 B Street, Marysville CA 95901 — 530.741.6000 ❑ Oroville Elementary School District, 2795 Yard Street, Oroville CA 95966 — 530.532.3000 V Oroville Union High, 2211 Washington Ave, Oroville CA 95966 — 530.538.2300 Ext: 105 ❑ Paradise Unified School District, 6696 Clark Road, Paradise CA 95969 — 530.872.6400 OTHER 5r Recorded copy of Agricultural Acknowledgment Statement - See Attached Instructions ❑ City of Biggs Planning Department, 3016 Sixth Street Biggs CA 95917 — 530.868.5447 ❑ FEMA Flood Elevation Certificate (required within 48 hours or permit will be placed on hold until received) ❑ Other: "When filed, this application and all supporting material becomes subject to the California Public Records Act. All public information related to this application is subject to public inspection and will be posted on the County's website for electronic access. Signature of Applicant: �GL� & Date: --__2L10 I 0_ Department of Development Services Tim Snellings, Director Pete Calarco, Assistant Director 7 County Center Drive T: 530.538.7601 Buttecounty.net/dds Oroville, California 95965 F: 530.538.7785 NOTICE TO BUILDERS** Before your building permit can be issued, your plans must be checked for compliance with the California Building Codes. In addition, your plans are routed to other regulatory entities including but not limited to Planning, Public Works, Environmental Health, and the California Department of Forestry for their clearances and approvals. There are some things you can do to expedite your permit: - Make sure your application is complete. - Be responsive to requests from County departments for any additional materials or requirements. The Building Division places its highest priority on processing building permits as quickly as possible and each day that passes without a complete application adds to processing time. Every permit issued by the Building Official shall expire and become null and void if the work authorized by such permit'is not started or completed within one year from the date of issuance of such permit (per Butte County Code Chapter 26, Article 1, Section 263.1). A permit may be renewed (for a fee) prior to expiration a maximum of two (2) times, provided construction progress has been documented by the Building Division during each year during scheduled inspections. No changes may be made in the original plans and specifications for such work. In order to reinstate action on a permit after expiration, the permittee shall pay a new full permit fee and additional plan checking and documentation may be required. Upon completion of work covered by this permit, please contact this office for final inspection. As a reminder to you, it is illegal to occupy this building or any portion of the building for which this permit is issued without a final inspection. EXPIRATION OF PERMIT APPLICATION AND REFUND POLICY** Application for which a permit has not been issued will expire one year after date of application. Refunds may only be made upon written request by the person who originally paid the fees. Refunds for permit applications, if the permit has not issued, but not after 180 days from the date of fee payment. Fees paid at the time of application are for Plan Check and administration. The Plan Check portion of fees is refundable only if the permit is cancelled or withdrawn before any plan checking is done. Building Division costs will be deducted prior to authorizing a refund and a charge to process the refund application will be assessed. The current refund processing fee is $127.00. Refunds on permits (issued) may be requested prior to the expiration of the permit, provided no work has been done pursuant to the permit. An Inspection may be required (and deducted from any refund amount) to determine no work was done. Fee/refund information can be read on-line at http://municipalcodes.lexisnexis.com/codes/butteco/ "When filed, this application and all supporting material becomes subject to the California Public Records Act. All public information related to this application is subject to public inspection and will be posted on the County's website for electronic access. Permit Number: B16-1926 Date: 9/1/2016 Parcel Number: 028-360-013 Location: 227 CULET RANCH RD, OROVILLE Phone: 5035510519 Owner Name: DOVBUSH, YURIY & YELENA Description: REPL SFD LOG HOME (1168) COV (320) OPEN (270) Signature of Applicant: �L& Date: 9/1/2016 Eff i Department of Development Services i Tim Snellings, Director Pete Calarco, Assistant Director 7 County Center Drive T: 530.538.7601 Buttecounty.net/dds Oroville, California 95965 F: 530.538.7785 11 DEVELOPMENT SERVICES 11 National Pollutant Discharge Elimination System (NPDES) Phase II Construction Storm Water Permit and Storm Water Pollution Prevention Plan (SWPPP) Acknowledgment ]LESS THAN I ACRE] Reference Number: B16-1926 Date: 9/1/2016 Location: 227 CULET RANCH RD By: JMD Parcel Number: 028-360-013 Sub Type: SFD-CUSTOM/MODEL Owner Name: DOVBUSH, YURIY & YELENA Phone: 5035510519 Description: REPL SFD LOG HOME (1168) COV (320) OPEN (270) By signing below, I the project owner/owners' agent, certify that this project WILL NOT DISTURB 1 acre or more of land and that I therefore, do not need to apply for a Construction Storm Water Permit from the State of California Regional Water Quality Control Board. Phased projects that contain multiple site buildouts of less than one acre but when combined with subsequent phases total more than one acre of disturbed soil will require a Construction Storm Water Permit from the State of California Regional Water Quality Board. Signed e�?e Date 9/1/2016 Butte County Department of Development Services PERMIT CENTER y 7 County Center Drive, Oroville, CA 95965 Main Phone 530.538.7601 Fax 530.538.7785 FORM NW -ADHP-43 �m��a�-.bntteeauntv.n et- dds IMPORTANT! .NOTICE TO.PROPERTY OWNERR :' Dear Property Owner: An application for -a building permit has�been submi}rr =y ernaffi a-li tin oursel +asI : builder of the property improvements specified at > We are providing you with an Owner -Builder Acknowledgment: and- Information Verification Form to make you aware of your responsibilities and---possible---risk you )'may dncur by having4U permit issued in yourname as the Owner -Builder.- We�will=n'otmissue-a-:building•per*m-it;until'P- you have read,.initialed your:understanding.of each•prov.ision; sigged land returnedthisr. form to us at our official address:indicated: An•agent..ofithe=:owner.cannot.executeithis-;notice: unless you,. the property owner, obtain the -prior approval'ofthe.,:permitting;authority: OWNER'S ACKNOWLEDGM-ENT>AND.VERIIhIICA.TION OF. INFORMATION MUCHONS. Read and initial-eachstatement:belowao signifyjthatyoutunderstandorwerify.thi&:. information. 1. I understand a frequent practice.of unlicensed,,persons is -to have the property owner obtain an "Owner -Builder" building,permit-that erroneously implies tha&the property:owner..-is: providing his or her own.labor and material personally:.I, as:an Owner -Builder, may be.held liable and subject to serious financial, risk fo.r.py injuries sustained by an unlieensed,person;and' his or her.employees while working -on my.property. My homeowner's -insurance .maynot-provi& coverage for those injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers on my property. 2. I understand building permits are not required to be signed by property owners unless they are responsible for the construction and are not hiring a licensed'Coritractor to assume this responsibility. �3' nderstand as an "Owner -Builder" I am the responsible party of record on the permitA understand that I may protect myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my own. 4L�!4 I understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on permits and contracts. 5. Iunderstand if I employ or otherwise engage any persons, other than California licensed ntractors, and the total value of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer" under state and federal law. VZD_61i understand if I am considered an "employer" under state and federal law, I must register with the state and federal government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial risk. �7. I understand under California Contractors' State License Law, an Owner -Builder who builds single-family residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building Contractor. Page 1 of 2 Revised 7.20.2015 ya--8. I understand -as an Owner=Burlder-if I�sell•the property for which this permit is issued, I -May be -held liable for any financial or personal injuries sustained by any subsequent owner(s) at result from any latent construction.defects in the workmanship or materials. 9: I understand I may obtain more information- regarding my obligations as an "employer" from the Intemal:Revenue. Service'; the United=States Small iBusiness.Adniinistration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I .also understand I may contact the California Contractors' State License Board (CSLB) at 1-800-. 321-CSLB.(2752) or www.cslb.ca.gov.for more.information.about licensed.contractors. Fza 00. I am aware of and consent to anOwner-Builder building permit applied for in -my name, and understand that I.am the party legally and financially responsible for proposed construction activity. at. the following address: �I'l.I agree'that,'as`the party legally and financially respodsible-for this -proposed construction activity,, I will abide by all,applicable laws and'requireinents that govern Owner - Builders as well as employers. 12:`I;agree'.to:no*,.the-issuer. of -this form:immediately.bf°any*additions;'deletions,.ot changes.to *aiiy ofthe iriformatiomII have provided on this form: Licensed`contractors are regulated by laws designed to protect the public. If you contract with someone who does not•have I a license, the Contractors' State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. Tour only.remedy against -unlicensed Contractors ��� , may be in civil, court. Tt is also importanffor you to understand1hat if an ,unlicensed"Contractor br employee of that individual or firm is¢injured while working on your property, nyou may be he`lil liable'for`damages If you otitam a"permit a"s Owner` Builder and wish to i ii Cotractors, you willbe responsilil'e for verifying wliethei� or not those' Contraetors'are propecly'licensed.and the status of their workers' compensation insurance coverage.- Before overage: Before a building permit can be issued, this form must be completed and signed by the property owner'anil returned. to;the agency responsible for issuiug.the permit. Note: A. copy of the property owner's driver's license, form notdrization, or diher verification acceptable to the agency is required to be presented when the permit is issued to verify the property owner's signature Signature of property owner: Note: The following Authorization Form is required to be completed by the property owner only whendesignating an agent of the property owner to apply for a construction permit for the Owner Builder. AUTHORIZATION. OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Notice to Property Ownei, the execution of which I iinderstand is my personal responsibility, I hereby authori2V the following person(s) to act as my agents) to apply for, sign, and file the documents necessary to. obtain an Owner -Builder Permit for my project. Scope of Construction Project (porgD�eoscri�a) ption.of Wo k): Project Location or Address:.(.0 / Y���1�' Name of Authorized Agent: Address of Authorized Agent: Tel No: I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and certify its accuracy. Note: A copy of the owner's driver's license, form notarization, or other verification acceptable to the. agency is required to be presented when .the permit is issued to verify the property owner's signature. �y ,/) % Property Owner's Signature: Date: &7 (S/V /pj Revised 7.20.2015 Page 2of2 Permit Fee Details PERMIT NUMBER Ill e County Butte Count B16-1926 - I v Description: REPL SFD LOG HOME (1168) COV (320) OPEN (270) Type: RESIDENTIAL Subtype: SFD-CUSTOM/MODEL Status: UNDER REVIEW Applied: 9/1/2016 JMD Approved: Parcel No: 028-360-013 Site Address: 227 CULET RANCH RD OROVILLE,CA 95965 Subdivision: Block: Lot: Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $135,352.24 Occupancy Type: Construction Type: V -N Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 1 Details: 2 BEDROOM F_ ,9 CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY SF CRIMINAL JUSTICE 12 0010-4402300-422000 0 $1.40 $0.00 2% ADMIN SF CRIMINAL JUSTICE 12 5205-52050000-462000 0 $68.60 $0.00 98% SF FIRE 12 2% ADMIN 0010-4402300-422000 0 $2.80 $0.00 SF FIRE 12 98% 5223-52230000-462000 0 $137.20 $0.00 SF GNRL GOVT CW 12 0010-4402300-422000 0 $2.40 $0.00 2% ADMIN SF GNRL GOVT CW 12 5201-52010000-462000 0 $117.60 $0.00 98% SF GNRL GOVT UA 12 0010-4402300-422000 0 $2.40 $0.00 2% ADMIN SF GNRL GOVT UA 12 5206-52060000-062000 0 $117.60 $0.00 98% SF HEALTH & SS 12 2% 0010-4402300-422000 0 $0.60 $0.00 ADMIN SF HEALTH & SS 12 98% 5207-52070000-462000 0 $29.40 $0.00 Printed: Thursday, September 01, 2016 10:18:14 AM 1 of 4 SYSTEMS DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD BY SF JAIL FACILITY 5202-52020000-462000 0 $83.67 $0.00 SF LIBRARY 12 2% 0010-4402300-422000 0 $1.00 $0.00 ADMIN SF LIBRARY 12 98% 5212-52120000-462000 0 $49.00 $0.00 SF SHERIFF 12 2% 0010-4402300-422000 0 $4.20 $0.00 ADMIN SF SHERIFF 12 98% 5222-52220000-462000 0 $205.80 $0.00 SF TRNSPRTTN 12 2% 0010-4402300-422000 0 $6.60 $0.00 ADMIN SF TRNSPRTTN 12 98% 5215-52150000-462000 0 $323.40 $0.00 Total Paid for CFIFR SINGLE FAMILY 12: $1,153.67 $0.00 DB CA SB1473 100 DBCP 0010-4402400-4220000 $6.00 $6.00 9/1/16 B017094 103 CHECK DOVBUSH, YURIY & JMD YELENA Total Paid for DB CA SB1473 100 DBCP: $6.00 $6.00 DBCAS RES 100 0010-4402300-422000 0 $17.60 $17:60 9/1/16 B017094 103 CHECK DOVBUSH, YURIY & JMD DBCP YELENA Total Paid for DB CA SMTP RES 100 DBCP: $17.60 $17.60 DBF R3 DWLNG CSTM/MDL INSP FEE DB 0010-4402400-422000 1168 $1,659.60 $0.00' CPINSP DBF R3 DWLNG DOVBUSH, YURIY & CSTM/MDL PLAN CHK 0010-4402100-422000 1168 $1,106.40 $1,106.40 9/1/16 B017094 103 CHECK JMD YELENA FEE DB CPPCK Total Paid for DB R3 DWELLING -CUSTOM, MODEL 09: $2,766.00 $1,106.40 DBMSC TECH INVST FEE 1 0010-4403000-4220000 $27.66 $27.66 9/1/16 8017094 103 CHECK DOVBUSH, YURIY & JMD R OCC 09 D CPAA YELENA Total Paid for DB TECHNOLOGY INVESTMENT FEE: $27.66 $27.66 Printed: Thursday, September 01, 201610:18:14 AM 2 of 4 CRMrsreees Printed: Thursday, September 01, 2016 10:18:14 AM 3 of 4 SYSTEMS CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY DBEH BUILDING 0021-5400000-461199 0 $105.00 $105.00 9/1/16 B017094 103 CHECK DOVBUSH, YURIY & JMD REVIEW FEE PH EH YELENA Total Paid for DBEH BUILDING REVIEW FEE PH EH: $105.00 $105.00 DBFIRE FIRE FINAL INSPECTION RES 09 F 0010-1401000-461901 0 $0.00 $0.00 REGSVCSDIV Total Paid for DBFIRE FIRE FINAL INSPECTION RES 09 F $0.00 $0.00 REGSVCSDIV: DBFIRE FIRE PRE DOVBUSH, YURIY & PLNCK/INSP RES F 0010-1401000-461901 0 $228.00 $228.00 9/1/16 B017094 103 CHECK JMD YELENA REGSVCSDIV Total Paid for DBFIRE FIRE PRE PLNCK/INSP RES F $228.00 $228.00 REGSVCSDIV: DBMSC FIRE SAFE DOVBUSH, YURIY & STANDARDS REVIEW 09 0010-4402300-422000 0 $127.00 $127.00 9/1/16 B017094 103 CHECK JMD YELENA DB CPPC rotal Paid for DBMSC FIRE SAFE STANDARDS REVIEW 09 DB $127.00 $127.00 CPPC: DBMSC GEN'L PLAN DOVBUSH, YURIY & MAINT FEE R OCC 09 0010-4401200-461901 0 $124.47 $124.47 9/1/16 B017094 103 CHECK YELENA JMD DPADV- Total Paid for DBMSC GEN'L PLAN MAINT FEE R OCC 09 $124.47 $124.47 DPADV: DBMSC SCANNING FEE 1 0010-4402300-422000 0 $64.00 $64.00 9/1/16 8017094 103 CHECK DOVBUSH, YURIY & JMD 09 DB CPPC YELENA Total Paid for DBMSC SCANNING FEE 09 DB CPPC: $64.00 $64.00 Printed: Thursday, September 01, 2016 10:18:14 AM 3 of 4 SYSTEMS At the time of permit application, I was advised the above fees are required prior to issuance of the permit. These fees may change during the plan checking process. Signature: Date: 9/1/2016QV' ❑ I would like to defer the required impact fees as noted within this fee summary until prior to Final Inspection. I further understand that I am required to pay the requested deferred impact fees as noted within this fee summary, before I am allowed to schedule a Final Inspection. I will not be allowed to occupy the permitted structure until a final inspection has been performed and approved after all fees have been paid. Signature: Date: 9/1/2016 Pursuant to Government code Section 66020, you are.hereby notified those items listed above may have been imposed on your project. You have 90 days from the date of approval of the project or from the impostion of the above referenced items during which you may request a protest. The requirments for a protest are specified in Government Code Section 66020(a). Printed: Thursday, September 01, 201610:18:14 AM 4 of 4 (OU L.7 L./ SYSTEMS CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY DP PLANNING DOVBUSH, YURIY & CLEARANCE FOR 0010-4401300-461901 0 $81.50 $81.50 9/1/16 B017094 103 CHECK SMD YELENA PERMITS 09 DPCUR Total Paid for DP PLANNING CLEARANCE FOR PERMITS 09 $81.50 $81.50 DPCUR: At the time of permit application, I was advised the above fees are required prior to issuance of the permit. These fees may change during the plan checking process. Signature: Date: 9/1/2016QV' ❑ I would like to defer the required impact fees as noted within this fee summary until prior to Final Inspection. I further understand that I am required to pay the requested deferred impact fees as noted within this fee summary, before I am allowed to schedule a Final Inspection. I will not be allowed to occupy the permitted structure until a final inspection has been performed and approved after all fees have been paid. Signature: Date: 9/1/2016 Pursuant to Government code Section 66020, you are.hereby notified those items listed above may have been imposed on your project. You have 90 days from the date of approval of the project or from the impostion of the above referenced items during which you may request a protest. The requirments for a protest are specified in Government Code Section 66020(a). Printed: Thursday, September 01, 201610:18:14 AM 4 of 4 (OU L.7 L./ SYSTEMS PROPERTY LINE (560' I 1 (E) DRIVEWAY I I 1 I I I � I O I PORCH t<1 I 5 9 0 sq f t. z (E) TIG m -1 Cn i Lu �----� z pf-L V i -1 3 5' 6 1' to I(E) ELECTRICAL POL UB PANEL K I PROPOSED W n W LOG HOME n � I 768 sq.ft. O V i (E) WELL L I I I I r I I . (E) SHE I I I ' in (E) WELL I , I I PROPERTY LINE 660' ®f�T�f PLOT PLAN rnSCALE: 1: 30 M & N Designing TEL.(916)366-9731 3654 GOLDSBORO CT. SACRAMENTO CA 95827 Lic H 308505 _ ME3 U ❑ Z M lD 5 Q [� U_ m W N W J ❑ Ll J >Z r,x a N N ❑ Q SHEET List BUTTE ; A 1 - Plot Plan • Plan COUNTY 2 - Floor d Detaiil Details 5 - Loft 4 Loft Framing -2013 California Bung Code (CBC) 4 - Elevation Plan 0 1 ) ZO�i 5 - Gross Section A 6 - Electrical Roof Framing SEP 4 DEVELOPMENT SERVICES tDammon-o— PROPERTY LINE (560' I 1 (E) DRIVEWAY I I 1 I I I � I O I PORCH t<1 I 5 9 0 sq f t. z (E) TIG m -1 Cn i Lu �----� z pf-L V i -1 3 5' 6 1' to I(E) ELECTRICAL POL UB PANEL K I PROPOSED W n W LOG HOME n � I 768 sq.ft. O V i (E) WELL L I I I I r I I . (E) SHE I I I ' in (E) WELL I , I I PROPERTY LINE 660' ®f�T�f PLOT PLAN rnSCALE: 1: 30 M & N Designing TEL.(916)366-9731 3654 GOLDSBORO CT. SACRAMENTO CA 95827 Lic H 308505 _ ME3 U ❑ Z M lD 5 Q [� U_ m W N W J ❑ Ll J >Z r,x a N N ❑ Q 1. AO construction ction shall conform to the folBuildingcodas; -2013 California Bung Code (CBC) Cul nen=Rd .2013 California Residential Code (CRC) tDammon-o— •2013 California Mechanical Code (CMC) Blezaford=Gu1� ` -2013 California Plumbing Code (CPC) -2013 California Electrical Code (CEC) y -2013 California Building Energy Efficiency Standards (CES) -2013 California Fire Code (CFC) n .2013 California Green Building Standards Code (CalGreen) S'I -ANY OTHER APPLICABLE Slate, County or Local Regulations. 2. THE CONTRACTOR IS RESPONSIBLE TO CHECK THE PLANS AND IS TO NOTIFY THE DESIGNER OF ANY ERRORS OR OMISSIONS PRIOR TO THE START OF CONSTRUCTION. 3 HAVE�R SCALED IENDO �n DIMENSIONS. NOT DRAWINGS If SCALE: no PROPERTY LINE (560' I 1 (E) DRIVEWAY I I 1 I I I � I O I PORCH t<1 I 5 9 0 sq f t. z (E) TIG m -1 Cn i Lu �----� z pf-L V i -1 3 5' 6 1' to I(E) ELECTRICAL POL UB PANEL K I PROPOSED W n W LOG HOME n � I 768 sq.ft. O V i (E) WELL L I I I I r I I . (E) SHE I I I ' in (E) WELL I , I I PROPERTY LINE 660' ®f�T�f PLOT PLAN rnSCALE: 1: 30 M & N Designing TEL.(916)366-9731 3654 GOLDSBORO CT. SACRAMENTO CA 95827 Lic H 308505 _ ME3 U ❑ Z M lD 5 Q [� U_ m W N W J ❑ Ll J >Z r,x a N N ❑ Q September 28, 2016 Mike Tretyak 3654 Goldsboro Court, Sacramento, CA 95627 TEL: (916) 804-9380 Attn.: Mike Tretyak, f=ZSE:Ir1I= STRUCTURAL ENGINEERS 4` OCT 3 12016 7RB ANP Re: Job 2016-09434: Residence located at 227 Culet Ranch Road, Oroville, CA 95966. Subject: Plan Check #1 Item Al2: Please see detail 5/SD-1. Item A 14: Please see the revised detail 15/8131-1. Item S1: Yes, the Seismic Design Category is D. Please see revised Loading Criteria on Sheet SN -1. The original calculations reference SDC D. Item S2: Per the ASCE 7-10 Section 12.3.4.2 and Table 12.3-3, the redundancy factor is 1.3. See revised attached calculations. If you have any questions on the above, do not hesitate to. call. Prepared By: PZSE, Inc. — Structural Engineers Roseville, CA QROF SSI t,O ENr ETH q� rq�y Fy CZ C m LU No S3 8 * UP. 1.17 `req SrRUCT0k OF CA0F� �� ^ REVIEWED BUTTE FOR CODE COMPLIANCE COUNTY PERMIT # //�[� NOV 0 E 2016 OCT 26 2016 cid BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED 0=®R1'Fi;E.e41iBD ASSOCIATES UESEItV[( ESNT CODE COMPLIANCE DATE / / ' �' ! — - BY % I t, I O) O 131 8150 Sierra College Boulevard, Suite 150 • Roseville, CA 95661 • 916.961.3960 P • 91 6.961.3965 • p e.com 1/12 FU �h PZSE, INC - STRUCTURAL ENGINEERS WIND DESIGN PROCEDURE 20.00 ft Risk Category = II I, 11, III or IV (Table 1.5-1) Basic Wind Speed, V = 110 mph 26.5.1 Directionality Factor, Kd = 0.85 26.6 Surface Roughness Category C 26.7.2 Exposure Category = C 26.7.3 Pressure Coefficient, Kz 0.87 27.3.1 (Table 27.3-1) Topographic Factor, Kzt = 1.00 26.8 (Table 26.8-1) Velocity Pressure, qz or qh 22.91 psf 27.3.2 Gust Effect Factor G or Gf = 0.85 26.9.1 Enclosure Classification = Enclosed 11.4.3 SEISMIC DESIGN PROCEDURE Height of Structure, hn = 20.00 ft Reduncy Factor, p = 1.30 ✓ Risk Category = II I, II, Ill or IV (Table 1.5-1) Response Modification Factor, R = 4.5 Table 12.2-1 Importance Factor = 1.0 Table 11.5-1 Mapped Acceleration Parameter, Ss = 0.586 g 11.4.1 and USGS maps Mapped Acceleration Parameter, S1 = 0.256 g 11.4.1 and USGS maps . Site Classification = D 11.4.2 (Table 20.3-1) Site Coefficient, Fa = 1.331 11.4.3 (Table 11.4-1) Site Coefficient, Fv = 1.888 11.4.3 (Table 11.4-2) Adjusted Max Spectral Response, Sms = .0.780 g 11.4.3 Adjusted Max Spectral Response, Sml = 0.483 g 11.4.3 Design Spectral Acceleration Parameter, Sds = 0.520 g 11.4.4 MCE response= Sds x 1.5 (11.4.6) Design Spectral Acceleration Parameter, Shc = 0.322 g 11.4.4 MCE response = Shc x 1.5 (11.4.6) Fundamental Period of Structure, Ta = 0.189 12.8.2 (light framed buildings only) Constant Velocity Transition Period, Ts = 0.620 sec Short Period Seismic Design Category, 0.2 sec = D 11.6 and 11.6-1 1-s Period Seismic Design Category, 1.0 sec = D N/A as Seismic Design Category (Table 11.6-2) Not Req Seismic Design Category, Sl = N/A BUTTE COUNTY BUILDING DIVISION APPROVED 2/12 PZSE,INC- STRUCTURALENGINEERS MULTI -STORY SEISMIC FORCE DISTRIBUTION Risk Category = II Importance Factor = 1.0 Site Classification = D i Response Modification Factor, R = 4.5 Mapped Acceleration Parameter, Ss = 0.586 g Mapped Acceleration Parameter, S1= 0.256 g Site Coefficient, Fa = 1.331 Site Coefficient, Fv = 1.888 Seismic Design Category, 0.2 sec = D Seismic Design Category, 1.0 sec = D N/A as Seismic Design Category (Table 11.6-2) Not Required Seismic Design Coefficient, Cs = 0.116 x W (LRFD design level) Service Level Seismic Force, Eh = J 0.105 = 0.7 x Cs x p x W (Allowable stress design level) 5 TABLE OF BUILDING WEIGHTS the wind lateral base shear calculation. Where Snow Loads Occur: Flat roof snow loads of 30 psf or less need not be combined with seismic loads. For flat roof snow loads exceed 30 psf, 20% shall be combined with seismic loads. TABLE OF SEISMIC FORCES AT BUILDING LEVEL: ALLOWABLE STRESS DESIGN LEVEL Walls Parallel to Front - Rear Direction Level Height Weight hi x wi Fx Story OTM Floor OTM Level Weight Total Length Height of Projected Weight Note: Only 1/2 of the first floor wall height is 0 0 7392. (psf) of wall (ft) Wall (ft) Area (sf) (Ibs) considered in the calculation. This corresponds with 1st floor 30 64 9.25 296 1 8880 the wind lateral base shear calculation. Walls Parallel to Left - Right Direction Level Weight Total Length Heightof Projected Weight Note: Only 1/2 of the first floor wall height is (psf) of wall (ft) Wall (ft) Area (sf) (Ibs) considered in the calculation. This corresponds with 1st floor 30 48 9.25 222 6660 the wind lateral base shear calculation. TABLE OF SEISMIC FORCES AT BUILDING LEVEL: ALLOWABLE STRESS DESIGN LEVEL I Level Height Weight hi x wi Fx Story OTM Floor OTM hi (ft) wi (Ibs) (Ibs) Shear (Ibs) (ft-Ibs) (ft-Ibs) Roof 9.25 70300 650275 7392 68377 1st floor 0 0 0 7392. 0 68377 DIAPHRAGM FORCE DISTRIBUTION TABLE: ALLOWABLE STRESS DESIGN LEVEL I . Force Parallel to Front - Rear Direction Level Weight wpx (Ibs) Level Weight wpx (Ibs) Lateral Sum Sum Max Fi Fi wi 0.4SdslWpx Min 0.2Sdslwpx f Diaphragm F x Ibs Roof 61420 6458 6458 61420 12775 6387 6458 1st floor 0 0 0 0 0 0 0 0 0 0 0 0 i 3/12 7-10 sec. 12.10.1.1 ASCE 7-10 sec. 12.10.1.1 BUTTE COUNTY BUILDING DIVISION APPROVED Force Parallel to Left - Right Direction Level Weight wpx (Ibs) Lateral Sum Fi Fi Sum wi. Max 0.4Sdslwpx Min 0.2Sdslwpx { Diaphragm F x Ibs Roof -63640 6692 6692 63640 13237 6618 6692 1st floor 0 0 0 0 0 0 0 i 3/12 7-10 sec. 12.10.1.1 ASCE 7-10 sec. 12.10.1.1 BUTTE COUNTY BUILDING DIVISION APPROVED PZSE, INC - STRUCTURAL ENGINEERS WIND FORCE LATERAL DESIGN: FRr1NT - RFAR rNRFr-rlr)N Level Diaphragm Story Shear (lbs) Shear Top of Roof 1st floor top plate 4970 1st floor 4970 I FFT- RIfHT nIRFrTION Level Diaphragm Story Shear (lbs) Shear Top of Roof 1st floor top plate 6715 1st floor 6715 LATERAL GOVERNING CONDITIONS FRONT - REAR DIRECTION: Roof Diaphragm = Diaphragm load, w = Story Shear, V = LEFT -RIGHT DIRECTION: Roof Diaphragm = Diaphragm load, w = Story Shear, V = 6458 lbs Seismic Governs 269 plf 7392 lbs / ✓ Seismic Governs 6715 lbs Wind Governs 210 plf 7392 lbs / Seismic Governs 4/12 210 plf Left 24.00 ft Front ROOF 269 plf R Right BUTTE COUNTY BUILDING DIVISION APPROVED PZSE, INC - STRUCTURAL ENGINEERS DIAPHRAGM DEFLECTION LOCATION: GL1toGL2&GLAtoGLB Ins total = 'L bending + 'nsshear + 0 nail slip + 0 chord splice slip — C 5v12 vL � + ^ �t . 0.181 Ken + I� XJ Applied shear, v 269 plf Shear wall deflection: Diaphragm length, L 24.00 ft Defl due to bending, Ab 0.003 inches Diaphragm width, b 32.00 ft DefI due to shear, Av 0.021 inches SPS thickness 15/32 inch Defl due to nail slip, Ans 0.162 inches Size of nail, 8d etc 8d Defl due to chord slip, Acs 0.038 inches Nail spacing 6 inches oc Total diaphragm drift, AD 0.224 inches 2x6 top plate area, A 16.50 sq. inches Max diaphragm drift, AM 0.894 inches Story height 9.25 ft Allowable story drift 2.775 inches DIAPHRAGM DEFLECTION LOCATION: GL 1 to GL 2 & GL A to GL B 3 X IL total — � bending + L� shear + � /'fit nail slip + chord splice slip — Q C w + A + 0.188Len + . L Applied shear, v 210 pit Shear wall deflection: Diaphragm length, L 32.00 ft Defl due to bending, Ab 0.007 inches Diaphragm width, b 24.00 ft Defl due to shear, Av 0.022 inches SPS thickness 15/32 inch Defl due to nail slip, Ans 0.144 inches Size of nail, 8d etc 8d Defl due to chord slip, Acs 0.067 inches Nail spacing 6 inches oc Total story drift, AS 0.239 inches 2x6 top plate area, A 16.50 sq. inches Total story drift, AM 0.958 inches Story height 9.25 ft Allowable story drift 2.775 inches BUTTE COUNTY BUILDING DIVISION APPROVED 5/12 PZSE,INC- STRUCTURALENGINEERS FIRST FLOOR: GRIDLINE 1 wall Story shear, V 7392 lbs Tributary width 12.00 ft Total width 24.00 ft Gridline shear 3696 lbs LATERAL DESIGN FRONT -BACK Plate height 9.25 ft Total wall length 31.50 ft 2/3 dead load 186 plf Total SW lengths 9.50 ft Min SW Length 3.50 ft Wall shear 389 plf f/ Roof shear 117 plf Net shear 272 plf 1000 wall open wall open wall open wall open wall open wall open wall open wall open Lengths (ft) 0.00 11.00 6.00 4.00 3.50 7.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Force at Rt ends of wall/open'g (Ibs) 0 -1291 340 -130 821 0 0 0 0 0 0 0 0 0 0 0 SW height LION 9 9 9 9 9 9 9 9 Shear wall Type 3 3 1000 24-16d's at splice 11W`u Story shear, V -1000.�„S' -2000 Y� x;:1000 td ob17 00N,� 21 00- 2450 37 50 ^-%..31.50 " 31.60 �j}p31 SO. ��k 31 50 --31 50 x31 50 r St 50 31.50,,-V,3150 ',(,31:50%c..1.+ '3: d! a s aZ �' ' 3} - Y� r�T� t't� � t�'t X y * n ` -.s -.i L. -u x 755#a..,,s�7. $jh +i•<.� i ,J3 'x,. 4 tg f F z T.;...i,.�^ 7L �+u sZ�YF Total width Therefore use: 24-16d's at splice -------------------------------------------------- FIRST FLOOR: GRIDLINE 2 Story shear, V 7392 Ibs Tributary width 12.00 ft Total width 24.00 ft Gridline shear 3696 Ihs Ftg: V-0" x V-6" w/ (1) #4 T& B Plate height 9.25 ft Total wall length 32.00 ft 2/3 dead load 186 plf Total SW lengths 20.00 ft Min SW Length 10.00 ft Holdown Tension = 3813 Ibs Wall shear 185 plf. Roof shear 116 plf Net shear 69 plf Soo wall open wall open wall open wall open wall open wall open wall open wall open Lengths (ft) 0.00 7.00 10.00 4.00 10.00 1.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Force at Rt ends of wall/open'g (Ibs) 0 -809 -116 -578 116 0 0 0 0 0 0 0 0 0 0 0 SW height LION 9 9 9 9 9 9 9 9 Shear wall Type 1 1 Soo _ -5 C) '' '+ 0 7 00)p 21 00 37 0032 Damf x.92 00.E 3200 < 13200 a 32 00 32 00 -.. 32A0 +'` 3200 52.00 92 OD - �'�3Y s 00 -1000 �' 4:i'r ,max..:.-�` ..:k x- `ir7'uf�'�..",.-..x.: :�lQ:t. c'x"�u it7^•.^^ XiG"°�`."F'a'i-w'-'t.-^Y Therefore use: 24-16d's at splice Ftg: V-0" x V-6" w/ (1) M4 T& B 6/12 Holdown Tension = 1397 Ibs 5/8" 0 ROD a Symbol 5/8" 0 ROD t1 Symbol r PZSE,INC- STRUCTURALENGINEERS LATERAL DESIGN FRONT -BACK FIRST FLOOR: GRIDLINE A Story shear, V 7392 lbs Plate height 9.25 ft Total wall length 22.50 ft Wall shear 569 plf Tributary width 16 ft 2/3 dead load, 186 plf Total SW lengths 6.50 ft Roof shear 164 plf Total width 32 ft Min SW Length 3.25'ft Net shear 404 plf Gridline shear 3696 lbs 2000 ' wall open wall open wall open wall open wall open wall open wall open wall 0 hs (ft) 3.25 16.00 3.25 0.00• 0.00 0.00 0.00, 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 at Rt ends of 4.75 11.00 6.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 )pen'g (lbs) 1314 -1314. 0 0 0 0 0. 0 0 0 0 0 0 0 0 eight OON 9 9 9 9 9 9 9 9 wall Type 4 4 9 9 9 9 `9 9 2000 ' 1000MAN tsF nY x ,. ;..; s*^ ROOM 4" s 4 'Ct4'4Y 3S: Y , 2'Ykd���'24�5�:�•.1i 0 -1000 -2000 ra 3'25 2 22 22 5D� 22 5D xf'�`22 50.VQV 22 5D+L k22 5D `22 50 22 5Di 22 5D 150 22 SD7 - � 22 50' r�22 50. ?Z �Lmuk..N..��''+c`�.T.'._�':.•°v�4 t �xc�' �•,aki!i �.i'n'"':'a<,..d+�.•p.a nro'�sma4...,. a. 50 "4�75�'� 6 5 1i'T5 275G� 21p75�'�y21r7` - 21?75172175-.i2175t775'�°21�'75;�275 Therefore use: 24-16d's at splice -------------------------------------------------- FIRST FLOOR: GRIDLINE B Story shear, V 7392 lbs Tributary width 12 ft Total width 32 ft 5/8" 0 ROD a Ftg: 1'-0" x V-6" w/ (1) #4 T & B Holdown Tension = 5670 lbs Symbol ---------------------------------------------------------------------------------------------------------------------------------------------------- Plate height 9.25 ft Total wall length 21.75 ft Wall shear 258 plf 2/3 dead load 186 plf Total SW lengths 10.75 ft Roof shear 127 plf Min SW Length 4.75 ft Net shear 130 off ne shear 2772 lbs 'Ct4'4Y 3S: Y , 2'Ykd���'24�5�:�•.1i 0 "4�75�'� 6 5 1i'T5 275G� 21p75�'�y21r7` - 21?75172175-.i2175t775'�°21�'75;�275 -1000• wall open wall open wall . open wall open wall open wall open wall open wall o hs (ft) 4.75 11.00 6.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 at Rt ends of )pen'g (lbs) 619 -782 0 0 0 0 0 0 0 0 0 0 .0 0 0 eight LION 9 9 9 9 9 9 `9 9 wall Type 1 1 1000 .. s n�7 x 'Ct4'4Y 3S: Y , 2'Ykd���'24�5�:�•.1i 0 "4�75�'� 6 5 1i'T5 275G� 21p75�'�y21r7` - 21?75172175-.i2175t775'�°21�'75;�275 -1000• �. .27z75�;"21 S. 7 Therefore use: 24-16d's at splice Ftg: 1'-0" x 1'-6" w/ (1) #4 T & B 7/12 " 5/8" 0, ROD a Holdown Tension = 2407 lbs Symbol I i •' t i BUTTE COUNTY BUILDING DIVISION Title: DOVBUSH LOG CABIN Job # 2016-09434 lip 17 Dsgnr: P.K. ZACHER, S.E. Date: 4:40PM, 28 SEP 16 Description : RESIDENCE Scope: STRUCTURAL ENGINEERING Rev: 580000 user: KW0602844,Ver 5.8.0,, -Nov -2006 Horizontal Plywood Diaphragm Page 1 (c)1983-2006 ENERCALC Engineering Software Dovbush Log Cabin.emCalculations Description ROOF General Information North-South Length 32.00 ft Diaphrgm Weight 0.00 psf East-West Length 24.00 ft Seismic Factor 1.0000 Nort-South Chord East-West Chord Thickness 32.00 ft 24.00 ft Diaphragm is Unblocked Blocking Direction North-South Boundary Loads Acting North & South Value Distance # 1 269.00 #/ft from 0.000 ft to 24.000 ft # 2 #/ft from 0.000ft to 0.000 ft # 3 #/ft from 0.000 ft to 0.000 ft # 4 #/ft from 0.000 ft to 0.000 ft Boundary Loads Acting East & West Thickness Grade Nail Size Spacing Value Distance # 1 210.00 #/ft from 0.000 ft to 32.000 ft in #/ft ft # 2 #/ft from 0.000 ft to 0.000 ft 2,3,12 200.0 0.00 # 3 #/ft from 0.000ft to 0.000 ft 2.5,4,12 200.0 0.00 # 4 #/ft from 0.000 ft to 0.000 ft 4,6,12 180.0 0.00 North & South Walls Design Data & Nailing Requirements 2x 1/2" Grade C-D,C-C 8d 6,6,12 180.0 3rd zone 2x 1/2" Grade C-D,C-C Shear Zone 180.0 Framing Thickness Grade 3x Nail Size Spacing Value Distance 200.0 in At East Wall 3x 1/2" in #/ft ft At North Wall 3x 1/2" Grade C-D,C-C 8d 2,3,12 265.0 0.00 2nd zone 3x 1/2" Grade C-D,C-C North 8d 2.5,4,12 265.0 0.00 3rd zone 2x 1/2" Grade C-D,C-C 3,360.0 lbs 8d 4,6,12 240.0 0.00 Center zone 2x 1/2" GradeC-D,C-C 140.00 #/ft 8d 6,6,12 240.0 3rd zone 2x 1/2" Grade C-D,C-C 8d 4,6,12 240.0 0.00 2nd zone 3x 1/2" Grade C-D,C-C 451.5 lbs 8d 2.5,4,12 265.0 0.00 At South Wall 3x 1/2" Grade C-D,C-C 605.3 lbs 8d 2,3,12 265.0 0.00 East & West Walls Design Data & Nailing Requirements 456.3 lbs 844.5 lbs Framing Thickness Grade Nail Size Spacing Value Distance in in #/ft ft At West Wall 3x 1/2" Grade C-D,C-C 8d 2,3,12 200.0 0.00 2nd zone 3x 1/2" Grade C-D,C-C 8d 2.5,4,12 200.0 0.00 3rd zone 2x 1/2" Grade C-D,C-C 8d 4,6,12 180.0 0.00 Center zone 2x 1/2" Grade C-D,C-C 8d 6,6,12 180.0 3rd zone 2x 1/2" Grade C-D,C-C 8d 4,6,12 180.0 0.00 2nd zone 3x 1/2" Grade C-D,C-C 8d 2.5,4,12 200.0 0.00 At East Wall 3x 1/2" Grade C-D,C-C 8d 2,3,12 200.0 0.00 Shear & Chord Forces Diaphragm Shears... North South West East Total Shear 3,360.0 lbs 3,360.0 lbs 3,228.0 lbs 3,228.0 lbs Shear per Foot 140.00 #/ft 140.00 #/ft 100.88 #/ft 100.88 #/ft Chord Forces... @ 1/4' Length 451.5 lbs 835.5 lbs @ 1/2' Length 605.3 lbs 1,120.0 lbs @ 3/4' Length 456.3 lbs 844.5 lbs Length / Width Ratio 1.333 BUTTE COUNTY BUILDING DIVISION APPROVED 8/12 Title: DOVBUSH LOG CABIN Job # 2016-09434 Dsgnr: P.K. ZACHER, S.E. Date: 4:40PM, 28 SEP 16 Description : RESIDENCE Scope: STRUCTURAL ENGINEERING Rev:580004 User: KW -0602844, Ver 5.8.0, 1 -Nov -2006 Plywood Shear Wall & Footing Page 1 (c)1983-2006 ENERCALC Engineering Software Dovbush Log Cabin.ecw:Calculations Description FIRST FLOOR: GRIDLINE 1 (for uplift calculation only) General Information Base allowables are user defined I # Plywood Layers 1 Wall Length 3.500 ft tna Host uimension 3.50 to Plywood Grade Grade C -D Wall Height 10.250 ft Seismic Factor 0.000 Nail Size 8d Wall Weight 0.000 psf Nominal Sill Thick. 2.00 Thickness 3/8" Ht / Length 2.929 0.00 lbs Stud Spacing 16.00 in Strut Force Applied @ Top of Wall Loads Moment Applied @ Top of Wall 0.00 ft-# Vertical Loads... Footing Overburden Load over Footing 100.00 psf Point Load # 1 0.00 lbs at 0.00 ft Concrete Weight 145.00 pcf Point Load # 2 0.00 lbs at 0.00 ft 3.00 in Past Right Edge of Wall Point Load # 3 0.00 lbs at 0.00 ft Footing Length 17.500 ft Uniform Load # 1 100.00 #/ft 0.00 ft to 3.50 ft Uniform Load # 2 0.00 #/ft 0.00 ft to 0.00 ft Lateral Loads... Uniform Shear @ Top of Wall 389.00 #/ft 3.500 ft = 1,361.50 lbs Uniform Shear @ Top of Wall 0.00 #/ft 3.500 ft = 0.00 lbs Strut Force Applied @ Top of Wall 0.00 lbs Strut Force Applied @ Top of Wall 0.00 lbs Moment Applied @ Top of Wall 0.00 ft-# Footing Past Left Edge of Wall 7.000 ft Concrete Weight 145.00 pcf Wall Length 3.500 ft Rebar Cover 3.00 in Past Right Edge of Wall 7.000 ft fc 2,500.00 psi Footing Length 17.500 ft Fy 40,000.00 psi Footing Width 1.00 ft Min. Steel As % 0.00000 Footing Thickness 18.00 in Design OK Wall Summary... Using 3/8" Thick Grade C -D on 1 side/s, Nailing is 8d at 3 in @ Edges, 8d at 12 in @ Field Applied Shear = 389.0#/ft, Capacity = 490.000#/ft -> OK Wall Overturning = 13,955.4ft-#, Resisting Moment = 612.5ft-#, End Uplift = 3,812.25lbs Max. Soil Pressures: @ Left = 650.9psf, @ Right = 650.9psf Sill Bolting: 1/2" Bolts @ 26.05in, 5/8" Bolts @ 40.62in, 3/4" Bolts @ 48.00in BUTTE COUNTY BUILDING DIVISION APPROVE® 9/12 Title: DOVBUSH LOG CABIN Job # 2016-09434 Dsgnr: P.K. ZACHER, S.E. Date: 4:40PM, 28 SEP 16 Description : RESIDENCE Scope : STRUCTURAL ENGINEERING Rev: 580004 User: KW -0602844, Ver 5.8.0, 1 -Nov -2006 Plywood Shear Wall & Footing Page 1 (c)1983-2006 ENERCALC Engineering Software Dovbush Log Cabin.ecw:Calculations Description FIRST FLOOR: GRIDLINE 2 (for uplift calculation only) General Information Base allowables are user defined I # Plywood Layers 1 Wall Length 10.000 ft tna cost uimension 3.50 to Plywood Grade Grade C -D Wall Height 10.250 ft Seismic Factor 0.000 Nail Size 8d Wall Weight 0.000 psf Nominal Sill Thick. 2.00 Thickness 3/8" Ht / Length 1.025 0.00 lbs Stud Spacing 16.00 in Strut Force Applied @ Top of Wall Loads Moment Applied @ Top of Wall 0.00 ft-# Vertical Loads... Footing Overburden Load over Footing 100.00 psf Point Load # 1 0.00 lbs at 0.00 ft Concrete Weight 145.00 pcf Point Load # 2 0.00 lbs at 0.00 ft 3.00 in Past Right Edge of Wall Point Load # 3 0.00 lbs at 0.00 ft Footing Length 24.000 ft Uniform Load # 1 100.00 #/ft 0.00 ft to 10.00 ft Uniform Load # 2 0.00 #/ft 0.00 ft to 0.00 ft . Lateral Loads... Uniform Shear @ Top of Wall 185.00 #/ft 10.000 ft = 1,850.00 lbs Uniform Shear @ Top of Wall 0.00 #/ft 10.000 ft = 0.00 lbs Strut Force Applied @ Top of Wall 0.00 Itis Strut Force Applied @ Top of Wall 0.00 lbs Moment Applied @ Top of Wall 0.00 ft-# Footing Past Left Edge of Wall 7.000 ft Concrete Weight 145.00 pcf Wall Length 10.000 ft Rebar Cover 3.00 in Past Right Edge of Wall 7.000 ft fc 2,500.00 psi Footing Length 24.000 ft Fy 40,000.00 psi Footing Width 1.00 ft Min. Steel As % 0.00000 Footing Thickness 18.00 in Design OK Wall Summary... Using 3/8" Thick Grade C -D on 1 side/s, Nailing is 8d at 6 in @ Edges, 8d at 12 in @ Field Applied Shear = 185.0#/ft, Capacity = 260.000#/ft -> OK Wall Overturning = 18,962.5ft-#, Resisting Moment = 5,000.Oft-#, End Uplift = 1,396.25lbs Max. Soil Pressures: @ Left = 585.6psf, @ Right = 585.6psf Sill Bolting: 1/2" Bolts @ 48.00in, 5/8" Bolts @ 48.00in, 3/4" Bolts @ 48.00in BUTTE COUNTY BUILDING DIVISION APPROVE® 10/12 Title: DOVBUSH LOG CABIN Job # 2016-09434 i Dsgnr: P.K. ZACHER, S.E. Date: 4:40PM, 28 SEP 16 Description : RESIDENCE Scope : STRUCTURAL ENGINEERING Rev: 580004 User. KW -0602844, Ver 5.8.0,1 -Nov -2006 Plywood Shear Wall & Footing Page 1 (c)1983-2006 ENERCALC Engineering Software Dovbush Log Cabin.ecw:Calculations Description FIRST FLOOR: GRIDLINE A (for uplift calculation only). General Information Base allowables are user defined M # Plywood Layers 1 Wall Length 3.250 It End Post Dimension 3.50 in Plywood Grade Grade C -D Wall Height 10.250 ft Seismic Factor 0.000 Nail Size 8d Wall Weight 0.000 psf Nominal Sill Thick. 2.00 Thickness 3/8" Ht/Length 3.154 0.00 lbs Stud Spacing 16.00 in Strut Force Applied @ Top of Wall Loads Moment Applied @ Top of Wall 0.00 ft-# Vertical Loads... Footing Overburden Load over Footing 100.00 psf Point Load # 1 0.00 lbs at 0.00 ft Concrete Weight 145.00 pcf Point Load # 2 0.00 lbs at 0.00 ft 3.00 in Past Right Edge of Wall Point Load # 3 0.00 lbs at 0.00 It Footing Length 15.250 ft Uniform Load # 1 100.00 #/ft 0.00 It to 3.25 It Uniform Load # 2 0.00 #/ft 0.00 It to 0.00 It Lateral Loads... Uniform Shear @ Top of Wall 569.00 #/ft 3.250 ft = 1,849.25 lbs Uniform Shear @ Top of Wall 0.00 #/ft 3.250 ft = 0.00 lbs Strut Force Applied @ Top of Wall 0.00 lbs Strut Force Applied @ Top of Wall 0.00 lbs Moment Applied @ Top of Wall 0.00 ft-# Footing Past Left Edge of Wall 6.000 ft Concrete Weight 145.00 pcf Wall Length 3.250 ft Rebar Cover 3.00 in Past Right Edge of Wall 6.000 ft fc 2,500.00 psi Footing Length 15.250 ft Fy 40,000.00 psi Footing Width 1.00 ft Min. Steel As % 0.00000 Footing Thickness 18.00 in Design OK Wall Summary... Using 3/8" Thick Grade C -D on 1 side/s, Nailing is 8d at 2 in @ Edges, 8d at 12 in @ Field Applied Shear = 569.0#/ft, Capacity = 640.000#/ft -> OK Wall Overturning = 18,954.8ft-#, Resisting Moment = 528.1ft-#, End Uplift = 5,669.75lbs Max. Soil Pressures: @ Left = 1,007.3psf, @ Right = 1,007.3psf Sill Bolting: 1/2" Bolts @ 17.81 in, 5/8" Bolts @ 27.77in, 3/4" Bolts @ 39.27in BUTTE COUNTY BUILDING DIVISION APPROVED 11/12 Title: DOVBUSH LOG CABIN Job # 2016-09434 Dsgnr: P.K. ZACHER, S.E. Date: 4:40PM, 28 SEP 16 Description : RESIDENCE PZH Scope: STRUCTURAL ENGINEERING Rev: 560004 user: KW-0602844, Ver 5.8.0, 1-Nov-2006 Plywood Shear Wall & Footing Page 1 (c)1983-2006 ENERCALC Engineering Software Dovbush Log Cabin.emCalculations Description FIRST FLOOR: GRIDLINE B (for uplift calculation only) General Information Base allowables are user defined N # Plywood Layers 1 Wall Length 4.750 ft trio cost ulmenslon 3.50 In Plywood Grade Grade C -D Wall Height 10.250 ft Seismic Factor 0.000 Nail Size 8d Wall Weight 0.000 psf Nominal Sill Thick. 2.00 Thickness 3/8" Ht /Length 2.158 0.00 lbs Stud Spacing 16.00 in Strut Force Applied @ Top of Wall Loads Moment Applied @ Top of Wall 0.00 ft-# Vertical Loads... Footing Overburden Load over Footing 100.00 psf Point Load # 1 0.00 lbs at 0.00 ft Concrete Weight 145.00 pcf Point Load # 2 0.00 Ibs at 0.00 ft 3.00 in Past Right Edge of Wall Point Load # 3 0.00 lbs at 0.00 ft Footing Length 16.750 ft Uniform Load # 1 100.00 #/ft 0.00 ft to 4.75 ft Uniform Load # 2 0.00 #/ft 0.00 ft to 0.00 ft Lateral Loads... Uniform Shear @ Top of Wall 258.00 #/ft 4.750 ft = 1,225.50 lbs Uniform Shear @ Top of Wall 0.00 #/ft 4.750 ft = 0.00 lbs Strut Force Applied @ Top of Wall 0.00 lbs Strut Force Applied @ Top of Wall 0.00 lbs Moment Applied @ Top of Wall 0.00 ft-# Footing Past Left Edge of Wall 6.000 ft Concrete Weight 145.00 pcf Wall Length 4.750 It Rebar Cover 3.00 in Past Right Edge of Wall 6.000 ft fc 2,500.00 psi Footing Length 16.750 ft Fy 40,000.00 psi Footing Width 1.00 ft Min. Steel As % 0.00000 Footing Thickness 18.00 in Design OK Wall Summary... Using 3/8" Thick Grade C -D on 1 side/s, Nailing is 8d at 6 in @ Edges, 8d at 12 in @ Field Applied Shear = 258.0#/ft, Capacity = 260.000#/ft -> OK Wall Overturning = 12,561.4ft-#, Resisting Moment = 1,128.1ft-#, End Uplift = 2,407.00lbs Max. Soil Pressures: @ Left = 653.8psf, @ Right = 653.8psf Sill Bolting: 1/2" Bolts @ 39.28in, 5/8" Bolts @ 48.00in, 3/4" Bolts @ 48.00in BUTTE COUNTY BUILDING DIVISION APPROVED 12/12 t CERTIFICATE OF COMPLIANCE RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: 227 Culet Ranch Rd: (Oroville) Calculation Date/Time: 17:18, Mon, Oct 24, •2016 !fir e1r!1ri + %_Ivet<. - -_. - Calculation Description: Title 24 -Analysis Input File Name: T-24 227 Culet Ranch Rd.ribd RECEIVEDF1R-PRF-01 Page 1 of 7 OCT 3 1 20;6 GENERAL INFORMATION hS 01 Project Name 227 Culet Ranch Rd. (Oroville) 02 03 This building incorporates features that require field testing and/or verification by a certified HERS rate, under the supervision of a CEC-approved HERS provider. - .�... ..1 a 1 r.e �. y.+....., f a _ t it •t ... .+/ .. ,. o . r s... .. r. This building incorporates ones bre Special Features'shown_below 02 Calculation Description Title 24 Analysis 08 Energy Use (kTDV/ftZ-yr) 03 Project Location 227 Culet Ranch Rd. Compliance Margin - - Percent Improvement 04 City Oroville, CA 05 Standards Version Compliance 2015 06 Zip Code 95965 07 Compliance Manager Version BEMCmpMgr 2013-4 (744) 08 Climate Zone CZ11 09 Software Version CBECC-Res 2013-4 (744) 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 0 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 i 14 Total Cond. Floor Area (ft) 768 15 Number of Zones 1 BUTTE 16 Slab Area (ft) 0 17 Number of Stories 2 COUNTY 18 Addition Cond. Floor Area N/A 19 Natural Gas Available No OCI 28 2m 20 Addition Slab Area (ftZ) N/A 21 Glazing Percentage (%) 14.3% COMPLIANCE RESULTSSLIMCES 01 Building Complies with Computer, Performance It �"""" Si 1tt tL41101- 02 03 This building incorporates features that require field testing and/or verification by a certified HERS rate, under the supervision of a CEC-approved HERS provider. - .�... ..1 a 1 r.e �. y.+....., f a _ t it •t ... .+/ .. ,. o . r s... .. r. This building incorporates ones bre Special Features'shown_below 06 07 08 PERMIT # (Q . / J BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR COE C, Registration Number: 216-No1705108-000000000-0000 %/d(� !/ e it oQ Ti.�g�o-za 17:24:24 + �fr+mnliance IIZ04072016-/744 CA Building Energy Efficiency Standards - 2013 R�[T Report Version - �fj REVIEWED FOR CODE COMPLIANCE N�jLnL n 8 �%016 •F7�� PiovideP CaICERTS inc. Report Generated at: 2016-10-24 17:18:58 TRB AND ASSACIA)4ES 41 ENERGY USE SUMMARY 1 04 05 06 07 08 Energy Use (kTDV/ftZ-yr) Standard Design Proposed Design ` Compliance Margin - - Percent Improvement Space Heating 55.80 41.01 14.79 26.5% Space Cooling 56.60 59.08 -2.48 -4.4% IAQ Ventilation 1.37 1.37 0.00 0.0% Water Heating 70.35 70.35 0.00 0.0%— Photovoltaic Offset ---- 0.00 0.00 ---- Compliance Energy Total 184.12 171.81 12.31 6.7% PERMIT # (Q . / J BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR COE C, Registration Number: 216-No1705108-000000000-0000 %/d(� !/ e it oQ Ti.�g�o-za 17:24:24 + �fr+mnliance IIZ04072016-/744 CA Building Energy Efficiency Standards - 2013 R�[T Report Version - �fj REVIEWED FOR CODE COMPLIANCE N�jLnL n 8 �%016 •F7�� PiovideP CaICERTS inc. Report Generated at: 2016-10-24 17:18:58 TRB AND ASSACIA)4ES 41 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD BUTTE COUNTY Project Name: 227 Culet Ranch Rd. (Oroville) Calculation Date/Time: 17:18, Mon, Oct 24, 20BUILDING DIVISION C`nIenlatinn rlaccrintinn• Titles 9A Analvcie Input Fila Name- T19d 997 Cnlpt Ranch PH rihri A nnA - __ CF1 R -PRF -01 Page 2 of 7 HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • IAQ mechanical ventilation • High R -value Spray Foam Insulation Cooling System Verifications: • Minimum Airflow • Refrigerant Charge HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications: • --None -- ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for,energy use"components included in,the'performancecom`plia'nce approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not r{egulatedtby Title Part6:(such as ;domestic es and consum} er elecfioncs)�`and accounting for the annual TDV energy offset by an on-site renewable energy system. IL Referenpe Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/f2-yr)* 1278.72-- 266.41 12.31 4.4% * includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems 227 Culet Ranch Rd. (Oroville) 768 1 1 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Floor Area Avg. Ceiling Zone Name _ Zone Type HVAC System Name (ft) Height Water Heating System 1 Water Heating System 2 Main Level 1 �; "`"' Conditioned HVAC System 1 768• _ -8.5 Water Heater •_ J�VS �� � F�ii', Registration Number: 216-NO17051OB-000000000-0000 y CA Building Energy Efficiency Standards - 2013 Residential Compliance Jl P „ Registration Date/Time: -'t � 2016-10-24 17:24:24 HERS Provider: CaICERTS inc. Report Version - CF1R-04072016-744 Report Generated at: 2016-10-24 17:18:58 V CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: 227 Culet Ranch Rd. (Oroville) Calculation Date/Time: 17:18, Mon, Oct 24, 2016 Calculation Description: Title 24 Analysis i. Input File Name: T-24 227 Culet Ranch Rd.ribd BUTTE COUNTY BUILDING DIV66fl-e 3PRF-01 of 7 APPROVELY OPAQUE SURFACES 01 02 03 04 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) Front Wall Main Level Log Wall 0 Front 272 48 90 Left Wall Main Level Log Wall 90 Left 204 18 90 Rear Wall Main Level Log Wall 180 Back 440 32 90 Right Wall Main Level Log Wall 270 Right 224 52 90 Ceiling (below attic) 1 Main Level Attic w/ spray foam 9.0 0.32 768 Insect Screen (default) Mud Room Floor Over Crawlspace Main Level FlrVentOvrCrawl 2x6 16oc R19 3.0 3.0 768 9.0 0.32 ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Asphalt Shingle Roof Ventilated 4 0.1 0.85 Yes No WINDOWS 01 02 03 04 Name 01 02 r. ��- 03 � { ��_. ( i �I�E U4 05 J, 1 i O6; r ,. 07 08 09 10 Name Type Surface (Orientation-Anmuth) Width (ft) Height Multipli er Area (ft2) U -factor SHGC Exterior Shading Kitchen Window Front Wall (Front -0) 4.0 3.0 1 12.0 0.32 0.25 Insect Screen (default) Dining Window Front Wall (Front -0) 4.0 4.0 1 16.0 0.32 0.25 Insect Screen (default) Bath Window Left Wall (Left -90) 3.0 3.0 1 9.0 0.32 0.25 Insect Screen (default) Mud Room Window Left Wall (Left -90) 3.0 3.0 1 9.0 0.32 0.25 Insect Screen (default) Living Rm Window Rear Wall (Back -180) 4.0 4.0 1 16.0 0.32 0.25 Insect Screen (default) Bedroom Window Rear Wall (Back -180) 4.0 4.0 1 16.0 0.32 0.25 Insect Screen (default) Living R Window Right Wall (Right -270) 4.0 4.0 1 16.0 0.32 0.25 Insect Screen (default) Dining Window Right Wall (Right -270) 4.0 4.0 1 16.0 1 0.32 0.25 Insect Screen (default) DOORS 01 02 03 04 Name Side of Building Area (ft) U -factor Entry Door Front Wall 20.0 0.50 Living Rm Door Right Wall 20.0 0.50 Registration Number: 216-NO17051OB-000000000-0000 Registration Date/Time: 2016-10-24 17:24:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-10-24 17:18:58 BUTTE COUNTY CERTIFICATE:OF.COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: 227 Culet Ranch Rd. (Oroville) Calculation Date/Time: 17:18, Mon, Oct 24,94DING DIVISION Calculation Description: Title 24 Analysis Input File Name: T-24 227 Culet Ranch R&APPROVED CF1 R -PRF -01 Page 4 of 7 OVERHANGS AND FINS 01 02 03,` _ !r�^""s ..04 t 05 t ,..• ., 06 07 r ! � )Total Cavity t' ',r 01 02 03 04 05 06 07 08 09 10 11 12 13 14 -1 D tL Inside Finish: Gypsum Board Overhang Left Fin Sheathing /Insulation: Wood Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Distl- Bot Up Depth Top Up Dist R Bot Up Kitchen 11 1 10 10 1 0 0 0 0 0 0 0 0 Dining 2 1 10 10 1 0 0 0 0 0 0 0 0 Bath 2 0 0 0 0 0 0 0 0 0 0 0 0 Mud Room 2 0 0 0 0 0 0 0 0 0 0 0 0 Living Rm 2 0 0 0 0 0 0 0 0 0 0 0 0 Bedroom 2 0 0 0 0 0 0 0 0 0 0 0 0 Living R 7 1 15 12 1 0 00 0 0 0 0 0 Dining 7 1 12 12 1 0 0 0 0 0 0 0 0 OPAQUE SURFACE CONSTRUCTIONS 01 02 03,` _ !r�^""s ..04 t 05 t ,..• ., 06 07 r ! � )Total Cavity t' ',r ;Winter Design Construction Name Surface Type < �Construction_Type 1Framing � R -value U value Assembly Layers S P -1 D tL Inside Finish: Gypsum Board Sheathing /Insulation: Wood Siding/sheathing/decking • Cavity / Frame: no insul. / 2x4 • Sheathing/ Insulation: R13 Sheathing • Exterior Finish: Wood Existing exterior wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.058 Siding/sheathing/decking • Cavity/ Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Asphalt Shingle Roof Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing., Light Roof (Asphalt Shingle) • Floor Surface: Hardwood Floors Over Floor Deck: Wood Siding/sheathing/decking FlrVentOvrCrawl 2x6 16oc R19 Crawlspace Wood Framed Floor 2x10 @ 16 in. O.C. R19 0.049 Cavity/Frame: R -19/2x10 • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R -18.8/2x8 Attic w/ spray foam attic) Wood Framed Ceiling 2x8 @ 24 in. O.C. R 38 0.026 Over Floor Joists: R-19.1 insul. • Insulation/Furring: no insul. / 5 in. wd • Mass Layer: 12 in. Log • Insulation/Furring: no insul. / 5 in. wd • Exterior Finish: Wood Log Wall Exterior Walls Adobe / Strawbale / Log 0.054 Siding/sheathing/decking Registration Number: 216-NO17051OB-000000000-0000 Registration Date/Time: 2016-10-24 17:24:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-10-24 17:18:58 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: 227 Culet Ranch Rd, (Oroville) , Calculation Date/Time: 17:18, Mon, Oct 24, 2016 Calculation Description:,Title 24 Analysis Input File Name: T-24 227 Culet Ranch Rd.ribd BUTTE COUNWF1R-PRF-01 BUILDING DIVISIOI*age 5 of 7 APPROVE® BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Required Not Required --- WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) Water Heater - 1/1 DHW Standard 40Gal WH, 0.7 - 90% 1 - none - WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) 40Ga1 WH, 0.7 - 90% Propanes Small Storage" "" 40��_.i ( 0.640000-Btu/hr 0 0 WATER HEATING - HERS VERIFICATION ``,� I= It. c r> ll:� 1-1% % ! il i r_% J= n 01 02 " 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation Control Central DHW Distribution Water Heater - 1/1 --- --- --- --- --- SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Cooling System 1:Heating System 1:Distribution Variable Outdoor Air Ventilation Central Heat/Cool Heating System 1 Cooling System 1 None Distribution System 1 System 1::3 System HVAC - HEATING UNIT TYPES 01 02 03 Name Type Efficiency Heating System 1 CntrlFurnace - Fuel -fired central furnace 93 AFUE Registration Number: 216-NO17051OB-000000000-0000 Registration Date/Time: 2016-10-24 17:24:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 Report Generated at: 2016-10-24 17:18:58 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: 227. Culet Ranch Rd. (Oroville) Calculation Date/Time: 17:18, Mon, Oct OLRVE COUNTY Calculation Description: Title 24 Analysis Input File Name: T-24 227 Culet Rancl�„I>�INC1 DIVISION APPRnVPD CF1 R -PRF -01 Page 6 of 7 HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 Name Verified Airflow Efficiency Verified EER Multi -speed Verified Refrigerant Charge Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling System 1 SplitAirCond 11.3 13 Not Zonal Single Speed Cooling System 1 -hers -cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling System 1 -hers -cool Required 350 Not Required Not Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 01 02 03 04 05 06 07 Name Type Y-. Duct Leakage Insulation R -value Duct Location Bypass Duct HERS Verification Distribution System 1 x DuctsAttict.y _ If 'Sealed and tested _ ) ; , r 1� 8 f } iAttic/'" Distribution System None 1 -hers -dist HVAC DISTRIBUTION - HERS VERIFICATION `'�� H F R11; P R 0 V I R 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Distribution System 1 -hers -dist Required 6.0 Not Required Not Required Not Required Not Required --- IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 22.68 0.25 Default 0 Required Registration Number: 216-NO17051OB-000000000-0000 Registration Date/Time: 2016-10-24 17:24:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-10-24 17:18:58 ' - - UTTE COUNTY CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD BF1 R -PRF -01 Project Name: 227 Culet Ranch Rd. (Oroville) , Calculation Date/Time: 17:18, Mon, Oct 24, 2016 BUILDING DIVIS1O Page 7 of 7 Calculation Description: Title 24 Analysis Input File Name: T-24 227 Culet Ranch Rd.ribd APPROVED DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Nataliya Tretyak Company: Signature Date: M&N Designing 2016-10-24 17:24:24 Address: CEA/HERS Certification Identification (If applicable): 3654 Goldsboro Ct N/A City/State/Zip: Phone: Sacramento, CA 95827 916-366-9731 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency, for approval with this building permit application. y _... . , ..__ Responsible Designer Name:Responsible L I ' L I DesignerSighaturte: Nataliya Tretyak Company: Date Signed: 2016 1`0 M&N Designing 24 17:24:24 Address: License: 3654 Goldsboro Ct N/A City/State/Zip: Phone: Sacramento, CA 95827 916-366-9731 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-NO17051OB-000000000-0000 Registration Date/Time: 2016-10-24 17:24:24 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 HERS Provider: CaICERTS inc. Report Generated at: 2016-10-24 17:18:58 August 30, 2016 Mike Tretyak 3654 Goldsboro Court Sacramento, CA 95627 TEL: (916) 804-9380 FAX: (91) 366-9731 Attn.: Mike Tretyak Re: Job 2016-09434: Dovbush Log Cabin f=ZSE: Inc STRUCTURAL ENGINEERS RECEIVED SEP 0 6- 20153 TRB AND ASSOCIATES The following calculations are for the Structural Engineering Design for the project located at 227 Culet Ranch Road, Oroville, CA 95966. f If you have any questions on the above, do not hesitate to ca Prepared By: PZSE, Inc. - Structural Engineers Roseville, CA BUTTE COUNTY SEP 01 2016 DEVELOPMENT SERVICES B/6- )9a6 REVIEWED FOR CODE COMPLIANCE PERMIT # ��i0 i�L NOV 0 8 2016 BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR TRB AND ASSOCIATES � CODE COMPLIANCE � , DATE//-.. .9V&-- -----BY/22 8150. Sierra College Boulevard, Suite 150 Roseville, CA 95664. 916.961.3960 P • 916.961.3965 = www.pzse.com t_ BUTTE COUNTY PROJECT NAME: BUILDING DIVISION PROJECT JOB NUMBER: APPROVE® PROJECT ARCHITECT: BUILDING CODE: TYPE OF CONSTRUCTION: Roof: Composition over wood LOADING: Roof: Pg = N/A Dead Load: Deflection Requirements: Roof: Dr= Floor: Df= Partion: Df= Balcony: Db = Deck: Dd = Wall: DW = Dovbush Log Cabin 2016-09434 Mike Tretyak. 2013 CALIFORNIA BUILDING CODE Floor: Wood joists Walls: Wood 22 psf 15 psf N/A 15 psf 15 psf 30 psf Live Load: BUTTE COUNTY BUILDING DIVISION Roof: Lr= 20 psf APPROVE® Floor: Lf= 40 psf Light Storage LSt = N/A Deck: Ld = 40 psf Snow Load: Roof: Pg = N/A Deflection Requirements: Roof: Live Load= L/240 Total Load= L/180 Floor: Live Load= L/360 Total Load= L/240 FOUNDATION: Allowable soil bearing pressure: Dead load + Live load= 1500 psf 2/34 tPZSE,INC- STRUCTURALENGINEERS I i " UNIFORM LOAD UNIFORM LOAD WALL POINT LOAD 1 POINT LOAD 2 Length Contr uniform uniform length Contr uniform uniform length uniform Contr point point dist from Contr point point I dist from I 8M ft width (ft) DL LL from -to width (ft) DL U. from -to DL area (s DL U. Lt area sf) DL U. It rafter 10/1.5' 2 40 40 0 0 0 0 0 0 deck Joist 10' 1.33 20 53 0 0 0 0 0 0 dbi deck Joist 10' 3.5 53 140 0 0 0 0 0 0 deck rim Joist 8' 5 75 200 1 17' 4 88 80 0 0 0 0 0 0 2 17' 4. 88 80 0 0 0 0 0 0 3 4/11' 3.75 83 75 0 0 0 0 0 0 4 11' 6.5 143 130 0 0 0" 0 0 0 5 13' 4 88 80 D -3/1D-13' 2.5 55 50' 3-10' 83R 510 413 6.75' 84R 918 715 3'/10' 6 8/8/4' 6.5 143 130 0 0 0 0 0 0 7 17' 4 60 160 0 0 0 0 0 0 8 1 17/4' 1 4 60 160 0 0 1 1 0 0 1 0 0 BUTTE COUNTY BUILDING DIVISION APPROVE® f 3/34 B I. �I F O R T E ` MEMBER REPORT Level, Floor: Joist PASSED 1 1 pieces) 9 1/2" T3I@ 110 @ 16" OC 0 Overall Length: 11'7* �t, ;T i. Ir y(�.itta +kit � • •. it 6 e11�"fi� L ,-�ctga4.� .r � `�"�C _ `} �.'�� !� ,. 11' 0 9 All locations are measured from the outside face of left support (or left cantilever end).AII dimensions are horizontal. BUTTE COUNTY BUILDING DIVISION ° APPROVE® Desi 11.ResUliSr,•.r...,.�-..yAdtial�t,okatJon n r wocarfon Ailotwed.: Residt� LDF:load Ctierl�natioit(PatOern) Member Reaction (lbs) 425 @ 2 1/2" 1375 (3.50") Passed (31%) 1.00 1.0 D + 1.0 L (All Spans) Shear (lbs) 403 @ 3 1/2" 1220 Passed (33%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft -lbs) 1143 @ 5'9 1/2" 2500 Passed (46%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Dell. (in) 0.111 @ 5' 9 1/2" 0.279 Passed (L/999+) -- 1.0 D + 1.0 L (All Spans) Total Load Defl. (in) 0.153 @ 5'9 1/2" 0.558 Passed (L/875) — 1.0 D + 1.0 L (All Spans) T3 -Pro'" Rating 53 50 Passed — uenecuon m[ena: LL tU4tlu) and 1 L (U140). Bracing (Lu): All compression edges (top and bottom) must be braced at 4' 9/16" o/c unless detailed otherwise. Proper attachment and positioning of lateral bracing is required to achieve member stability. A structural analysis of the deck has not been performed. • Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser Edge- Panel (24" Span Rating) that Is glued and nailed down. Additional considerations for the T3 -Pro'" Rating include: 1/2" Gypsum ceiling. irK�; b J k4' B�Anglenplfl h *Tr + rCoadstoSupports(lbs).v a, " + # c � akSv r#s9sfx ,Ss"tcn -'3r laza sSua' F itis ,+ t t :� }} p a .._a l dTii�ta !4a RequlrBd ?}d x �111ve 1 T .i 3 Aooassortes ^ 1- Beam - DF 3.50" 3.50• 1.75" 116 309 425 Blacking 2 - Beam - DF 3.50" 3.50" 1.75" 116 309 425 Blocking • mooring Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. �oacls n r wocarfon F} h we ,spaar!cso). SO; DBadc« (s oo)x cdniriteMsy� 1 - Uniform (PSF) 0 to 11'7" 16" 15.0 40.0 Residential - Living Areas Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Refer to current Weyerhaeuser literature for installation details. (www.woodbywy.com) Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR -1153 and ESR -1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports refer to http://www.woodbywy.com/services/s_CodeReports.aspx. The product application, Input design loads, dimensions and support information have been provided by Forte Software Operator Forte Software Ope7afoi Job Notes -- — PAULZACHER PLSE, INC. STRUCI'URAL ENGINEERS (916)961-3960 PAUL @PZSE.COIo-t 5/34 System : Floor Member Type : )Dist Building Use : Residential Building Code : IBC Design Methodology : ASD T SUSTAINABLE FORESTRY INITIATIVE 7/12/2016 9:10:40 AM Forte v5.0, Design Engine: V6.4.0.40 Forte.4te Page 1 of 1 _ s Inc STRUCTURAL ENGINEERS Project Title: BUTTE COUNTY Prloec Descr:BUILDING DIVISION Project ID: APPROVED Multiple Simple Beam k V �., „• File=P:TZSEIPROJECTFILESQ016jobs10ovbush Log Cabinl6.094341ENGRWvbushLog Cabin.ec6" fNERCALC,-INC-1983-2016, Build:6.16.4.12, Ver:6.16.4.12 Description : BEAM 1 - BEAM 6 'Wood Beam Design: BEAM 1 Calculations Der NDS 2012. IBC 2012. CBC 2013. ASCE 7-10 Size: 11.50 X 11.50, Sawn, Fully Unbraced Using Allowable Stress Design with IBC 2012 Load Combinations, Major Axis Bending Wood Species : Douglas Fir- Larch Wood Grade: No.1 Fb - Tension 1,200.0 psi Fc - Prll 1,000.0 psi Fv 170.0 psi Ebend- xx 1,600.0 ksi Density 31.20 pcf Fb - Compr 1,200.0 psi Fc - Perp 625.0 psi Ft 825.0 psi Eminbend - xx 580.0 ksi Applied Loads (k) D L Lr S W E H Beam self weight calculated and added to loads Unif Load: D = 0.0880, Lr = 0.080 k/ft, Trib=1.0 It Design Summary 431.14 psi at 8.500 ft in Span # 1 Max fb/Fb Ratio = 0.162. 1 fb : Actual : 336.32 psi at 8.500 ft in Span # 1 Fb : Allowable: 2,070.00 psi Load Comb: +D+Lr+H Max fv/FvRatio = 0.080: 1 fv : Actual : 16.94 psi at 16.093 ft in Span # 1 Fv : Allowable: 212.50 psi Load Comb: +D+Lr+H Max Reactions (k) D L �r S iN E Left Support 0.99 0.68 Right Support 0.99 0.68 Wood Beam Design: BEAM 2 r H Downward L+Lr+S 0.065 in Downward Total 0.159 in Upward L+Lr+S 0.000 in Upward Total 0.000 in Live Load Defl Ratio 3147 >360 Total Defl Ratio 1280 >300 Calculations per NDS 2012, IBC 2012, CBC 2613, ASCE 7-10 BEAM Size: 10.50 X 10.50, Sawn, Fully Unbraced Using Allowable Stress Design with IBC 2012 Load Combinations, Major Axis Bending Wood Species : Douglas Fir - Larch Wood Grade: No.1 Fb - Tension 1,200.0 psi Fc - Prll 1,000.0 psi Fv 170.0 psi Ebend- xx 1,600.0 ksi Density 31.20 pcf Fb - Compr 1,200.0 psi Fc - Perp 625.0 psi Ft 825.0 psi Eminbend - xx 580.0 ksi Applied Loads Beam self weight calculated and added to loads Unif Load: D = 0.0880, Lr = 0.080 k/ft, Trib=1.0 it Design Summary (k) D L Lr S W E H Max fb/Fb Ratio = 0.240. 1 fb : Actual : 431.14 psi at 8.500 ft in Span # 1 Fb: Allowable: 1,800.00 psi Load Comb: +D+Lr+H Max fv/FvRatio = 0.094: 1 fv : Actual : 19.97 psi at 16.150 ft in Span # 1 Fv: Allowable: 212.50 psi Load Comb: +D+Lr+H Max Reactions (k) D L Lr S W E H Downward L+Lr+S 0.093 in Downward Total 0.224 in Left Support 0.95 0.68 Upward L+Lr+S 0.000 in Upward Total 0.000 in Right Support 0.95 0.68 Live Load Defl Ratio 2187 >360 Total Defl Ratio 911 >300 'WoodlBeam Design- BEAM 3 Max fv/FvRatio = 0.063: 1 fv : Actual: 13.37 psi at 4.000 ft in Span # 1 Calculations per NDS 2012, IBC 2012, CBC 2013, ASCE 7-10 BEAM Size: 10.50 X 10.50, Sawn, Fully Unbraced +D+Lr+H, LL Comb Run (LL) Max Reactions (k) D L Lr ii W E Using Allowable Stress Design with IBC 2012 Load Combinations, Major Axis Bending 1.09 0.77 Wood Species: Douglas Fir - Larch Wood Grade: No.1 Fb - Tension 1,200.0 psi Fc - Prll 1,000.0 psi Fv 170.0 psi Ebend- xx 1,600.0 ksi Density 31.20 pcf Fb - Compr 1,200.0 psi Fc - Perp 625.0 psi Ft 825.0 psi Eminbend - xx 580.0 ksi Applied Loads Beam self weight calculated and added to loads Unif Load: D = 0.0830, Lr = 0.0750 k/ft, Trib=1.0 ft Design Summary Max fb/Fb Ratio = 0.081 • 1 fb : Actual : 145.55 psi at 5.940 ft in Span # 2 Fb: Allowable: 1,800.00 psi Load Comb: +D+Lr+H, LL Comb Run ('L) Max fv/FvRatio = 0.063: 1 fv : Actual: 13.37 psi at 4.000 ft in Span # 1 Fv : Allowable: 212.50 psi Load Comb: +D+Lr+H, LL Comb Run (LL) Max Reactions (k) D L Lr ii W E Left Support 1.09 0.77 Right Support 0.51 0.41 Q(0.0830Lr 0.0750 4.0 ft ii.oft, 10.50x10.50 Max Deflections H Downward L+Lr+S 0.015 in Downward Total 0.030 in Upward L+Lr+S -0.018 in Upward Total -0.026 in Live Load Defl Ratio 5410 >360 Total Defl Ratio 3692 >300 6/34 Project Title: BUTTE COUNTY !=5 "Mmomiric Engineer: Project ID: Project Descr: BUILDING DIVISION STRUCTURAL ENGINEERS APPROVED �Mdltple Simple Bea61File=RTZSETROJECTFILESQ016jobs0oybushLog Cabin l6 094341ENGRVDovtwshLogCabin.ec6 ENERCA,LC, INC.,1983.2016, Build:6.16.4.12; Ver.6.16.4.12; 'Wood Beam DeW' n`:' BEAM 4 i.. Calculations per NDS 2012, IBC 2012, CBC 2013, ASCE 7-10 BEAM Size: 10.50 X 10.50, Sawn, Fully Unbraced Using Allowable Stress Design with IBC 2012 Load Combinations, Major Axis Bending Wood Species: Douglas Fir - Larch Wood Grade: No.1 Fb - Tension 1,200.0 psi Fc - PHI 1,000.0 psi Fv 170.0 psi Ebend- xx 1,600.0 ksi Density 31.20 pcf Fb - Compr 1,200.0 psi Fc - Perp 625.0 psi Ft 825.0 psi Eminbend -)o( 580.0 ksi Applied Loads Beam self weight calculated and added to loads Unif Load: D = 0.1430, Lr = 0.130 k/ft, Trib=1.0 ft DeSrpn Summary (k) D L Lr s w E H Max fb/Fb Ratio = 0.155. 1 fb : Actual : 279.29 psi at 5.500 ft in Span # 1 Fb : Allowable: 1,800.00 psi Load Comb: +D+Lr+H Max tv/FvRatio = 0.089: 1 fv : Actual : 18.81 psi at 0.000 ft in Span # 1 Fv: Allowable: 212.50 psi Load Comb: +D+Lr+H Max Reactions (k) D L Lr s w E H Downward L+Lr+S 0.027 in Downward Total 0.061 in Left Support 0.92 0.72 Upward L+Lr+S 0.000 in Upward Total 0.000 in Right Support 0.92 0.72 Live Load Defl_ Ratio 4968 >360 Total Defl Ratio 2175 >300 Wood Beam Design: BEAM 5 t Calculations per NDS 2012, IBC 2012, CBC 2013, ASCE.?-10 BEAM Size: 11.50 X 11.50, Sawn, Fully Unbraced Using Allowable Stress Design with IBC 2012 Load Combinations, Major Axis Bending Wood Species : Douglas Fir- Larch Wood Grade: No.1 Fb - Tension 1,200.0 psi Fc - PHI 1,000.0 psi Fv 170.0 psi Ebend- xx 1,600.0 ksi Density 31.20 pcf Fb - Compr 1,200.0 psi Fc - Perp 625.0 psi Ft 825.0 psi Eminbend - xx 580.0 ksi Applied Loads Beam self weight calculated and added to loads Unif Load: D = 0.0880, Lr = 0.080 k/ft, 0.0 ft to 3.0 ft, Trib=1.0 ft Unif Load: D = 0.0550, Lr = 0.050 k/ft, 3.0 to 10.0 ft, Trib=1.0 ft Unif Load: D = 0.0880, Lr = 0.080 k/ft, 10.0 to 13.0 ft, Trib=1.0 ft Point: D = 0.9180, Lr = 0.7150 k @ 3.0 ft Point: D = 0.510, Lr = 0.4130 k @ 6.750 ft Point: D = 0.9180, Lr = 0.7150 k @ 10.0 ft Desi4n Summary Max fb/Fb Ratio = 0.289. 1 fb : Actual : 520.37 psi at 6.760 ft in Span # 1 Fb: Allowable: 1,800.00 psi Load Comb: +D+Lr+H Max fv/FvRatio = 0.159: 1 fv : Actual : 33.83 psi at 12.047 ft in Span # 1 Fv : Allowable: 212.50 psi Load Comb: +D+Lr+H Max Reactions (k) D i Lr S w E Left Support 1.81 1.33 Right Support 1.83 1.34 +++ .,+ 13.0 ft. 11.50XI1.50 •.t �..a.t�+,'-T- ,; -',� �"` � i..e2e.:-+�os���'-��'+�e �•a.s:,. T �'t ..tea.-3�-�` ns H Downward L+Lr+S 0.061 in Downward Total 0.144 in Upward L+Lr+S 0.000 in Upward Total 0.000 in Live Load Defl Ratio 2544 >360 Total Defl Ratio 1080 >300 7/34 lm�:Project Title: fs Engineer: BUTTE COUNTY Project ID: il='nC Project Descr: BUILDING DIVISION =zftWMWJ STRU(TURAI ENGINEERS APPROVE® Tr 1 ',.File= P IPZSEIPROJECT FILES12016 jobsV)ovbush Log Cabinl6_094341ENGRIDovbush Log Cabin.eG Wood Beam k_ ; ' e� '" d �ti ` . s-• ` ' ENERCALC, INC.19832016, BwId:6.16.6.7, Ver:6.16.6.7 Lic. # : KW -06002844. Licensee: PAUL ZACHER STRUCTURAL ENGINEER,%; Description : BEAM 6 CODE REFERENCES Calculations per NDS 2012, IBC 2012, CBC 2013, ASCE 7-10 Maximum Bending Stress Ratio = 0.2441 Load Combination Set: IBC 2012 7.0 X 7.0 fb : Actual = 476.28psi Material Properties = 1,950.0Opsi Load Combination +D+Lr+H, LL Comb Run (-L) Analysis Method: Allowable Stress Design Fb - Tension 1,200.0 psi E: Modulus of Elasticity Load Combination i BC 2012 Fb - Compr 1,200.0 psi Ebend- xx 1,600.Oksi +D+Lr+L+S+W+E+H, LL Comb Run (L' Fc - Prll 1,000.0 psi Eminbend - xx 580.Oksi Wood Species : Do.uglas Fir - Larch Fc - Perp 625.0 psi 0.0000 Wood Grade : No.1 Fv 170.0 psi Support notation : Far left is #1 Values in KIPS Ft 825.Opsi Density 31.20pcf Beam Bracing :Completely Unbraced Support 3 Support 4 D(0.1430) Lr(0.130 7.0 X 7.0 7.0 X 7.0 7.0 x 7.0 Span =8.0ft Span =8.0ft Span =4.0ft Applied:Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loads Loads on all spans... Uniform Load on ALL spans: D = 0.1430, Lr = 0.130 k/ft ' DESIGN'SUMMARY. Maximum Bending Stress Ratio = 0.2441 Section used for this span 7.0 X 7.0 fb : Actual = 476.28psi FB : Allowable = 1,950.0Opsi Load Combination +D+Lr+H, LL Comb Run (-L) Location of maximum on span = 8.000ft Span # where maximum occurs = Span # 2 Maximum Shear Stress Ratio Section used for this span fv : Actual Fv : Allowable Load Combination Location of maximum on span Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection 0.090 in Ratio= 1070>=360 Max Upward Transient Deflection -0.045 in Ratio= 2136>=360 Max Downward Total Deflection 0.143 in Ratio= 672 >=300. Max Upward Total Deflection -0.031 in Ratio = 3050>=300. 0.177 :1 7.0 X 7.0 37.57 psi 212.50 psi +D+Lr+H, LL Comb Run (LL') = 7.462 ft Span # 1 verall Maxiiium- Deflectionss Load Combination Span Max. ° " Defl Location in Span Load Combination Max. "+" Defl location in Span +D+Lr+L+S+W+E4H, LL Comb Run (L' 1 0.0572 3.832 0.0000 0.000 2 0.0000 3.832 +D+Lr+L+S+W+E+H, LL Comb Run (L' -0.0315 4.706 +D+Lr+L+S+W+E+H, LL Comb Run (L' 3 0.1426 4.000 0.0000 4.706 irekil Re16tions y Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Support 3 Support 4 Overall MAXimum 0.987 2.606 2.405 Overall MINimum 0.032 -0.195 -0.065 +D+Lr+L+S+W+E+H, LL Comb Run (-L) 0.532 1.111 1.950 +D+Lr+L+S+W+E+H, LL Comb Run ('L') 0.434 1.956 1.722 +D+Lr+L+S+W+E+H, LL Comb Run (*LL) 0.467 1.761 2.405 8/34 Project Title: BUTTE COUNTY Engineer: Project ID: Inc Project Descr: BUILDING DIVISION STRU(TURAL ENGINEERS APP��v�� �j-,Ftle,P1PZSE0ROJECTFILES12016jobslDovbushiogCab 6 �3AENGRIDovbushLog m r':- ': ` �'' �Y'a .. `. " ' ?s-:�";ENERCALC, INC..19832016:-Build:6.16.6.7. Vi Description : BEAM 6 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 -Support 2 Support 3 Support 4 +D+Lr+L+S+W+E+H, LL Comb Run (L") 0.954 1.956 1.202 +D+Lr+L+S+W+E+H, LL Comb Run (L•L) 0.987 1.761 1.885 +D+Lr+L+S+W+E+H, LL Comb Run (LL') 0.889 2.606 1.657 +D+Lr+L+S+W+E+H, LL Comb Run (LLL) 0.922 2.411 2.340 +D+W+H 0.499 1.306 1.267 +D+0.70E+H 0.499 1.306 1.267 +D+0.750Lr+0.750L+0.750W+H, LL Comb 0.524 1.159 1.779 +0+0.750Lr+0.750L+0.750W+H, LL Comb 0.451 1.793 1.609 +D+0.750Lr+0.750L+0.750W+H, LL Comb 0.475 1.647 2.120 +D+0.750Lr+0.750L+0.750W+H, LL Comb 0.841 1.793 1.219 +D+0.750Lr+0.750L+0.750W+H, LL Comb 0.865 1.647 1.730 +CA.750Lr+0.750L+0.750W+H, LL Comb 0.792 2.281 1.560 +D+0.750Lr+0.750L+0.750W+H, LL Comb 0.816 2.134 2.072 +0+0.750L+0.750S+0.750W+H, LL Comb 0.499 1.306 1.267 +D+0.750L40.750S+0.750W+H, LL Comb 0.499 1.306 1.267 +D+0.750L+0.750S+0.750W+H, LL Comb 0.499 1.306 1.267 +0+0.750L+0.750S+0.750W+H, LL Comb 0.499 1.306 1.267 +0+0.750L+0.750S+0.750W+H, LL Comb 0.499 1.306 1.267 +D+0.750L+0.750S+0.750W+H, LL Comb 0.499 1.306 1.267 +D+0.750L+0.750S+0.750W+H, LL Comb 0.499 1.306 1.267 +D+0.750Lr+0.750L+0.5250E+H, LL Com 0.524 1.159 1.779 +D+0.750Lr+0.750L+0.5250E+H, LL Com 0.451 1.793 1.609 +0+0.750Lr+0.750L+0.5250E+H, LL Com 0.475 1.647 2.120 +D+0.750Lr+0.750L+0.5250E+H, LL Com 0.841 1.793 1.219 +0+0.750Lr+0.75OL+0.5250E+H, LL Com 0.865 1.647 1.730 +D+0.750Lr+0.750L+0.52W+H, LL Com 0.792 2.281 1.560 +0+0.750Lr+0.750L+0.5250E+H, LL Com 0.816 2.134 2.072 +0.60D+W+0.60H 0.300 0.783 0.760 +0.60D+0.70E+0.60H 0.300 0.783 0.760 D Only 0.499 1.306 1.267 Lr Only, LL Comb Run ('•L) 0.032 -0.195 0.682 Lr Only, LL Comb Run (•L•) -0.065 0.650 0.455 Lr Only, LL Comb Run (*LL) -0.033 0.455 1.137 Lr Only, LL Comb Run (L") 0.455 0.650 -0.065 'Lr Only, LL Comb Run (L -L) 0.487 0.455 0.617 Lr Only, LL Comb Run (LL*) 0.390 1.300 0.390 Lr Only, LL Comb Run (LLL) 0.423 1.105 1.073 L Only, LL Comb Run (•'L) L Only, LL Comb Run (•L') L Only, LL Comb Run (*LL) L Only, LL Comb Run (L") L Only, LL Comb Run (L•L) L Only, LL Comb Run (LL') L Only, LL Comb Run (LLL) S Only W Only E Only H Only +D+H 0.499 1.306 1.267 +D+L+H, LL Comb Run (-L) 0.499 1.306 1.267 +D+L+H, LL Comb Run (•L•) 0.499 1.306 1.267 +D+L+H, LL Comb Run ('LL) 0.499 1.306 1.267 +D+L+H, LL Comb Run (L••) 0.499 1.306 1.267 +D+L+H, LL Comb Run (L'L) 0.499 1.306 1.267 +D+L+H, LL Comb Run (LL') 0.499 1.306 1.267 +D+L+H, LL Comb Run (LLL) 0.499 1.306 1.267 +D+Lr+H, LL Comb Run (•'L) 0.532 1.111 1.950 +D+Lr+H, LL Comb Run (•L•) 0.434 1.956 1.722 +D+Lr+H, LL Comb Run ('LL) 0.467 1.761 2.405 +D+Lr+H, LL Comb Run (L••) 0.954 1.956 1.202 9/34 1 Project Title: Engineer: BUTTE COUNTY Project ID: Project Descr: Inc BUILDING DIVISION STRUCTURAL ENGINEERS APPROVE® ^�s��''� File=P1PZSEIPROJECTFILES12016joDslDovbush.LogCabint6_094341ENGR1DovbushL Wood Beam �: s .. _ - -., t.. ,< -ya.. _ � � �c �• t:'x ;.': + , .: 'e:' «ENERCALC:INC:;19832016; Budii.6:16.6:7: Description : BEAM 6 Vertical`Read ions Support notation :Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Support 3 Support 4 +D+Lr+H, LL Comb Run (L'L) 0.987 1.761 1.885 +D+Lr+H, LL Comb Run (LL') 0.889 2.606 1.657 +D+Lr+H, LL Comb Run (LLL) 0.922 2.411 2.340 +D+S+H 0.499 1.306 1.267 +D+0.750Lr+0.750L+H, LL Comb Run (' 0.524 1.159 1.779 +D+0.750Lr+0.750L+H, LL Comb Run (' 0.451 1.793 1.609 +D40.750Lr+0.750L+H, LL Comb Run (' 0.475 1.647 2.120 +D+0.750Lr+0.750L+H, LL Comb Run (L 0.841 1.793 1.219 +D+0.750Lr+0.750L+H, LL Comb Run (L 0.865 1.647 1.730 +D+0.750Lr+0.750L+H, LL Comb Run (L 0.792 2.281 1.560 +D+0.750Lr+0.750L+H, LL Comb Run (L 0.816 2.134 2.072 +D+0.750L+0.750S+H, LL Comb Run (" 0.499 1.306 1.267 +D+0.750L+0.750S+H, LL Comb Run ('L 0.499 1.306 1.267 +D+0.750L+0.750S+H, LL Comb Run ('L 0.499 1.306 1.267 +0+0.750L+0.750S+H, LL Comb Run (L' 0.499 1.306 1.267 +D+0.750L+0.750S+H, LL Comb Run (L' 0.499 1.306 1.267 +D+0.750L+0.750S+H, LL Comb Run (LL 0.499 1.306 1.267 , +D+0.750L+0.750S+H, LL Comb Run (LL 0.499 1.306 1.267 +D+0.70E+H 0.499 1.306 1.267 +0+0.750L+0.750S+0.5250E+H, LL Comb 0.499 1.306 1.267 +0+0.750L+0.750S+0.5250E+H, LL Comb 0.499 1.306 1.267 +0+0.750L+0.750S+0.5250E+H, LL Comb 0.499 1.306 1.267 +D+0.750L+0.750S+0.5250E+H, LL Comb 0.499 1.306 1.267 +D+0.750L+0.750S+0.5250E+H, LL Comb 0.499 1.306 1.267 +0+0.750L+0.750S+0.5250E+H, LL Comb 0.499 1.306 1.267 +D+0.750L+0.750S+0.5250E+H, LL Comb 0.499 1.306 1.267 +0.60D+0.70E+0.60H 0.300 0.783 0.760 10/34 ' Project Title: Engineer:BUTTE COUNTY Project ID: Project Descr: Inc BUILDING DIVISION STRUCTURAL ENGINEERS APPROVE® IrIVIU'Itl ple Simple Beam a `�` ,-.;-�" File FP TZSETROJECT FILESA2016 jobs1Doftsh.Log Cabinl6_094341ENGRIDwtwsh Log Cabin�ed 9 _ "" ` t ENEF2CALC; INC. 1983 2016; Build,6.16.6.7; Ver.6,16.6.7 KW -06002844 Licensee: PAUL ZACHER STRUCTURAL ENGINEER, -INC.:, Description : BEAM 7 - BEAM 12 ° Wood Beam' Design : BEAM Calculations per`NDS,2012, IBC 2012, CBC 2013, ASCE 7-10 BEAM Size: 10.0X10.0, Sawn, Fully Unbraced Using Allowable Stress Design with IBC 2012 Load Combinations, Major Axis Bending Wood Species: Douglas Fir - Larch Wood Grade: No.1 Fb - Tension 1,200.0 psi Fc - Prll 1,000.0 psi Fv 170.0 psi Ebend- xx 1,600.0 ksi Density 31.20 pcf Fb - Compr 1,200.0 psi Fc - Perp 625.0 psi Ft 825.0 psi Eminbend -)(x 580.0 ksi Applied Loads Beam self weight calculated and added to loads Unif Load: D = 0.060, L = 0.160 k/ft, Trib=1.0 ft Design Summary (k) D L Lr S iN E H Max fb/Fb Ratio = 0.437-1 fb : Actual: 628.58 psi at 8.500 ft in Span # 1 Fb: Allowable: 1,440.00 psi Load Comb: +D+L+H Max fv/FvRatio = 0.164: 1 fv : Actual : 27.94 psi at 16.207 ft in Span # 1 Fv: Allowable: 170.00 psi Load Comb: +D+L+H Max Reactions (k) D L Lr S iN E H Downward L+Lr+S 0.227 in Downward Total 0.342 in Left Support 0.69 1.36 Upward L+Lr+S 0.000 in Upward Total 0.000 in Right Support 0.69 1.36 Live Load Defl Ratio 899 >360 Total Defl Ratio 595 >300 ,Wood,Beam Design: BEAM 7_ +D+L+H, LL Comb Run (L') j ` 0.159: 1 ` Calculations per NDS 2012, IBC 2012, C,BC 2013, ASCE'7-10 r BEAM Size: 10.50 X 10.50, Sawn, Fully Unbraced Load Comb: +D+L+H, LL Comb Run (LL) Max Reactions (k) Using Allowable Stress Design with IBC 2012 Load Combinations, Major Axis Bending Left Support Wood Species: Douglas Fir - Larch Wood Grade: No.1 ` Fb - Tension 1,200.0 psi Fc - Prll 1,000.0 psi Fv 170.0 psi Ebend- xx 1,600.0 ksi Density 31.20 pcf Fb - Compr 1,200.0 psi Fc - Perp 625.0 psi Ft 825.0 psi Eminbend - xx 580.0 ksi Applied Loads Beam self weight calculated and added to loads Unif Load: D = 0.060, L = 0.160 k/ft, Trib= 1.0 ft Design Summary Max fb/Fb Ratio = 0.366. 1 fb : Actual : 527.30 psi at 8.330 ft in Span # 1 Fb : Allowable: 1,440.00 psi Load Comb: +D+L+H, LL Comb Run (L') Max fv/FvRatio = 0.159: 1 N : Actual : 26.95 psi at 16.150 ft in Span # 1 Fv: Allowable: 170.00 psi Load Comb: +D+L+H, LL Comb Run (LL) Max Reactions (k) D L Lr S W E Left Support 0.67 1.36 Right Support 1.09 2.08 D 0.060 L 0.160 17.0 ft 4.0 ft, 10.50X10.50 H Downward L+Lr+S 0.187 in Downward Total 0.272 in Upward L+Lr+S - -0.140 in Upward Total -0.194 in Live Load Defl Ratio 686 >360 Total Defl Ratio 494 >300 11/34 PZSE,INC- STRUCTURALENSINEERS TIMBER COLUMN CAPACITES Grading: 2x4 Doug -fir larch: Stud 4x or greater Doug -fir larch: No. 1 Assumptions: 1. End conditions are pinned -pinned; K=1.0 2. Le xx, Le yy for axial and Lu xx for bending = column length 3. Load duration factor =1.0 COLUMN LENGTH = 7'-0" Member Area Capacity F'c 2-2x4 10.500 4,750 452 2-2x6 16.500 7,395 448 44 12.250 9,290 758 06 19.250 14,465 751 4x8 25.375 18,865 743 6x6 30.250 24,720 817 6x8 1 41.250 1 33,710 1 817 COLUMN LENGTH =10'-0" Member Area Capacity F'c 2-2x4 10.500 2570 245 2-2x6 16.500 4,030 244 4x4 12.250 4990 407 4x6 19.250 7810 406 4x8 25.375 10260 404 6x6 30.250 20140 666 6x8 41.250 27470 666 COLUMN LENGTH =13-0" Member Area Capacity F'c 2-2x4 10.500 1570 149 2-2x6 16.500 2,465 149 4x4 12.250 3030 247 4x6 19.250 4760 247 4x8 25.375 6270 247 6x6 30.250 14750 487 6x8 41.250 20120 487 COLUMN LENGTH =18-0" Member Area Capacity F'c 4x4 12.250 1610 131 4x6 19.250 2530 131 4x8 25.375 3330 131 6x6 30.250 8640 285 6x8 41.250 11780 285 COLUMN LENGTH = 9'-0" Membe'Capacity Area F'c 3 1/2" x 5 1/2" 15250 793 3 1/2" x 7 1/4" 20,110 793 5 1/4" x 5 1/2" 44920 1556 5 1/4" x 7 1/4'. 59210 1556 COLUMN LENGTH = 8-0" Member Area Capacity F'c 2-2x4 10.500' 3820 364 2-26 16.500 5970 362 4x4 12.250 7445 608 4x6 19.250 11630 604 4x8 25.375 15220 600 6x6 30.250 23440 775 6x8 41.250 31965 775 COLUMN LENGTH =11-0" Member Area Capacity F'c 2-2x4 10.500 2150 205 2-2x6 16.500 3,380 205 4x4 12.250 4170 341 46 19.250 6540 340 4x8 25.375 8600 339 6x6 30.250 18290 604 6x8 1 41.250 24940 6D4 COLUMN LENGTH = 14-0" Member Area . Capacity F'c 2-20 10.500 1360 129 2-2x6 16.500 2,135 129 40 12.250 2630 214 4x6 19.250 4130 214 4x8 25.375 5430 214 6x6 30.250 13200 436 6x8 41.250 1 18000 436 COLUMN LENGTH = 20-0" Member Area Capacity F'c 44 12.250 1310 107 4x6 19.250 2055 107 4x8 25.375 2710 107 6x6 30.250 7135 236 6x8 41.250 9730 236 LVL POST CAPACITIES COLUMN LENGTH =10'-0" Member Ca aci F'c 3 1/2" x 5 1/2" 12510 650 3 1/2" x 7 1/4" 16,490 650 5 1/4" x 5 1/2" 38590 1337 5 1/4" x 7 1/4" 50870 1337 12/34 BUTTE COUNTY BUILDING DIVISION APPROVE® COLUMN LENGTH = 9-0" Member Area Capacity F'c 2-2x4 10.500 3110 297 2-2x6 16.500 4,875 295 4x4 12.250 6050 494 46 19.250 9465 491 4x8 25.375 12410 489 6x6 30.250 21890 723 6x8 41.250 29850 1 723 COLUMN LENGTH =12-0" Member Area Capacity F'c 2-2x4 10.500 1830 174 2-2x6 16.500 2,870 174 4x4 12.250 3540 289 4x6 19.250 5550 288 48 25.375 7300 287 6x6 30.250 16460 544 6x8 41.250 1 22450 1 544 COLUMN LENGTH =16-0" Member Area Capacity F'c 2-2x4 10.500 1050 100 2-26 16.500 1,650 100 4x4 12.250 2030 165 46 19.250 3185 165 4x8 25.375 4195 165 6x6 30.250 10615 351 6x8 41.250 14475 351 COLUMN LENGTH = 22-0" Member Area Capacity F'c 4x4 12.250 1085 88 4x6 19.250 1705 88 4x8 25.375 2245 88 6x6 30.250 5970 197 6x8 41.250 8150 197 COLUMN LENGTH =12'-0" Member Capacity F'c 3 1/2" x 5 1/2" 8810 458 3 1/2"x 7 1/4" 11,610 458 1 5 1/4" x 5 1/2" 28380 983 5 1/4" x 7 1/4" 37410 983 PZ5E, INC - 5TRUCTURAL ENGINEERS BUTTE COUNTY BUILDING DIVISION ALLOWABLE FOOTING CAPACITY CALCULATIONS APPROVED DESIGN ASSUMPTIONS FOR CONTINUOUS FOOTINGS Axial Capacity = F.W. x 2 x F.D. x Allowable Bearing (pso/ 144 \ Allowable Soil Bearing Capacity = 1500 psf L Number of Floors Supported = 1 (Enter 1, 2, or 3) Footin g,- ......... """ ' Axial Capacity of Point Load Depth- F.D. on Continuous Footing 4500 lbs Footing Width - F.W. g = (inches) (inches) 2 x Footing Depth CALCULATED FOOTING DEPTH FOR SLAB ON GRADE (2) #4's, 3" clear top & bottom, U.O.N. •4" Slab on Grade 4" Chamfer Footing Depth 12 inches = Minimum Footing Depth Below Undisturbed Material • , �� ►�— 12 inches =Minimum Footing Width CALCULATED FOOTING DEPTH FOR STEMWALL FOOTING (2) #4's, 3" clear top & bottom, U.O.N.. 6" clear minimum Footing 6 inches = Minimum Stem Wall Width Depth 12 inches = Minimum Footing Depth Below Undisturbed Material • �. ►T 12 inches =Minimum Footing Width 13/34 i u PZSE, INC - STRUCTURAL ENGINEERS f BUTTE COUNTY BUILDING DIVISION DESIGN ASSUMPTIONS FOR ISOLATED SPREAD FOOTINGS FOOTINGS Ar r M® tl W. x W.) x Allowable Bearing (p.s.f.)/144 r Depth = 12" Minimum r s Width - W. (inches) Width - W. inches Isolated Footing Size inches Footing Capacity l� 24 x 241 6,000 30 x 30 9,375 36 x 36 13,500 42 x 42 18,375 48 x 48 24,000 54 x 54 30,375 60 x 60 37,500 66 x 66 45,375 72 x 72 54,000 14/34 y 0 1 BUTTE COUNTY LATERAL FORCE COMMENTS: BUILDING DIVISION APPROVE® Item 1: Where the roof structure is conventionally framed. The ceiling joists, collar ties, and ridge, hip and valley boards comply with section 2308.10.4 of the CBC. Since the roof slope is greater than 3:12, the ridge, hip and valley boards are not required to be designed as beams per section 2308.10 of the CBC and as a result, the struts supporting these members (where occurs) are for construction purposes only and are not required to be designed. However, as a conservative approach, loads were placed on the hip and valley boards and they were analyzed as beam elements. However, these are not required to have struts placed as a support. The purlins shall have 2x4 struts installed per Section 2320.12.7. Item 2: This is an engineered structure what is occurring is that the shear wall lines are being transferred via a drag strut into the roof and/ or floor diaphragm. Since the drag strut force is relatively low, a sub -diaphragm is not required. Details involving strap ties and blocking for the drag struts are called out in the "Framing Key Notes". The capacity for various connections are as listed below: Details utilizing CS16 strap ties: The capacity of one (1) CS16 x 6'-0" strap tie is 1705 lbs. The length of blocking is 6'-0" and has (18) 8's which will transfer a force of 18 x 76 lbs x 1.6 = 2,188 lbs. Two CS16 x 8'-0" long strap tie's capacity is 3410 lbs. The length of blocking is 8'-0" and will have (36) 8's which will transfer a force of 36 x 76 lbs x 1.6 = 4,378 lbs. The drag strut force will be.transferred through the sheathing to the adjacent rafters/ trusses that will disseminate the force through out the roof diaphragm (see CBC 2315.5.3). Taking one 4 ft x 8 ft sheet, the minimum number of 8d's will be 33 and would transfer a force of 4,013 lbs. The withdrawal capacity of the connection per strap = 18 nails x 28 lbs x 2.5" x 1.6 = 2,016 lbs. Details utilizing CMST12 strap ties and 4x blocking: The capacity the CMST12 strap tie is 9235 lbs. The length of blocking is 16'-0" and has (82)16d's which will transfer a force of 82 nails x 103 lbs x 1.6 =13,514 lbs. The drag strut force will be transferred through the sheathing to the adjacent rafters/ trusses that will disseminate the force through out the roof diaphragm (see CBC 2315.5.3). Taking one 4 ft x 8 ft sheet, the minimum number of 8d's will be 33 and would transfer a force of 4,013 lbs. The withdrawal capacity is 82 nails x 33 lbs x 3.5" x 1.6 = 15,153 lbs. 15/34 V PZ5E,INC STRUCTURAL ENGINEERS WIND DESIGN PROCEDURE Risk Category = Basic Wind Speed, V = Directionality Factor, Kd = Surface Roughness Category Exposure Category = Pressure Coefficient, Kz Topographic Factor, Kzt = Velocity Pressure, qz or qh Gust Effect Factor G or Gf = Enclosure Classification SEISMIC DESIGN PROCEDURE Height of Structure, hn = Reduncy Factor, p = Risk Category = Response Modification Factor, R = Importance Factor= Mapped Acceleration Parameter, Ss = Mapped Acceleration Parameter, S1= Site Classification = Site Coefficient, Fa = Site Coefficient, Fv = Adjusted Max Spectral Response, Sms = Adjusted Max Spectral Response, Sml = Design Spectral Acceleration Parameter, Sds = Design Spectral Acceleration Parameter, Sd1= Fundamental Period of Structure, Ta = Constant Velocity Transition Period, Ts = Short Period Seismic Design Category, 0.2 sec = 1-s Period Seismic Design Category, 1.0 sec = Seismic Design Category, Sl = it 110 mph 0.85 C C 0.87 1.00 22.91 psf 0.85 Enclosed 2 1.00 / 4.5 ✓ 1.0 0.586 g 0.256 g D 1.331 1.888 0.780 g 0.483 g 0.520 g 0.322 g 0.189 0.620 sec D D N/A 16/34 BUTTE COUNTY BUILDING DIVISION APPROVE® I, II, III or IV (Table 1.5-1) 26.5.1 26.6 26.7.2 26.7.3 27.3.1 (Table 27.3-1) 26.8 (Table 26.8-1) 27.3.2 26.9.1 I, II, III or IV (Table 1.5-1) Table 12.2-1 Table 11.5-1 11.4.1 and USGS maps 11.4.1 and USGS maps 11.4.2 (Table 20.3-1) 11.4.3 (Table 11.4-1) 11.4.3 (Table 11.4-2) 11.4.3 11.4.3 11.4.4 MCE response = Sds x 1.5 (11.4.6) 11.4.4 MCE response = Shc x 1.5 (11.4.6) 12.8.2 (light framed buildings only) 11.6 and 11.6-1 N/A as Seismic Design Category (Table 11.6-2) Not Req PZSE, INC - STRUCTURAL ENGINEERS BUTTE COUNTY BUILDING DIVISION MULTI -STORY SEISMIC FORCE DISTRIBUTION: ����®��® Roof Risk Category = II Importance Factor = 1.0 Site Classification = D Response Modification Factor, R = 4.5 Mapped Acceleration Parameter, Ss = 0.586 g Mapped Acceleration Parameter, S1= 0.256 g Site Coefficient, Fa = 1.331 Site Coefficient, Fv = 1.888 Seismic Design Category, 0.2 sec = D Seismic Design Category, 1.0 sec = D N/A as Seismic Design Category (Table 11.6-2) Not Required 1 Seismic Design Coefficient, Cs = 0.116 x W (LRFD design level) ' Service Level Seismic Force, Eh = 0.081 = 0.7 x Cs x p x W (Allowable stress design level) TABLE OF BUILDING WEIGHTS Floor and Roof Diaohraems Where Snow Loads Occur: Level Weight Average Average Projected Weight (psf) Length (ft) Width (ft) Area (sf) .(Ibs) Roof 37 40 37 1480 54760 1st floor Weight (Ibs) Walls Parallel to Front - Rear Direction Level Weight (psf) Total Length of wall (ft) Height of Wall (ft) Projected Area (sf) Weight (Ibs) 1st floor 30 64 9.25 296 1 8880 Walls Parallel to Left - Rieht Direction Level Weight (psf) 1 Total Length of wall (ft) 1 Height of Projected Wall (ft) Area (sf) 1 Weight (Ibs) 1st floor 30 48 9.25 222 6660 Flat roof snow loads of 30 psf or less need not be combined with seismic loads. For flat roof snow loads exceed 30 psf, 20% shall be combined with seismic loads. Note: Only 1/2 of the first floor wall height is considered in the calculation. This corresponds with the wind lateral base shear calculation. Note: Only 1/2 of the first floor wall height is considered in the calculation. This corresponds with the wind lateral base shear calculation. TABLE OF SEISMIC FORCES AT BUILDING LEVEL: ALLOWABLE STRESS DESIGN LEVEL Force Parallel to Front - Rear Direction Level Height Weight hi x wi Fx Story OTM Floor OTM hi (ft) wi (Ibs) (Ibs) Shear (Ibs) (ft-Ibs) (ft-Ibs) Roof 9.25 70300 650275 5686 52598 ist floor 0 0 0 1 5686 0 52598 ni ARNRArm Fr)Rr'F nICTRIRI IT10N TART F• AI 1 nWARI F CTRFCC n;:-urN I FVFI 9 17/34 OSCE 7-10 sec. 12.10.1.1 ASCE 7-30 sec. 12.10.1.1 Force Parallel to Front - Rear Direction Direction Level Weight wpx (Ibs) Lateral Sum Sum Fi Fi wi Max 0.4Sdslwpx Min 0.2Sdslwpx Diaphragm F x Ibs Roof 61420 4968 4968 61420 12775 6387 6387 1st floor 0 0 0. 0 0 0 0 9 17/34 OSCE 7-10 sec. 12.10.1.1 ASCE 7-30 sec. 12.10.1.1 Force Parallel to Left - Right Direction Level Weight wpx (Ibs) Lateral Sum Fi Fi Sum wi Max 0.4Sdslwpx Min 0.2Sdslwpx Diaphragm F x Ibs Roof 63640 5148 5148' 63640 13237 6618 6618 1st floor 0 0 0 0 1 0 0 0 9 17/34 OSCE 7-10 sec. 12.10.1.1 ASCE 7-30 sec. 12.10.1.1 BUTTE COUNTY BUILDING DIVISION APPROVE® MecaWind Pro v2.2.7.0 per ASCE 7-10 Developed by MECA Enterprises, Inc. Copyright www.mecaenterprises.com Date 7/8/2016 0.6*Ht Project No. 2016-09434 lzm: Cc*(33/Zm)^0.167 Company Name PZSE Inc. -Structural Engineers Designed By 1*(Zm/33)^Epsilon = 427.06 ft Address (1/(1+0.63*((B+Ht)/Lzm)^0.63))^0.5 Description Dovbush Log Cabin 0.925*((1+1.7*lzm*3.4*Q)/(1+1.7*3.4*lzm)) City -8.48 Customer Name -3.43 State Side Walls Proj Location -10.86 File Location: C:\Users\kyl.e\AppDat:a\Roarni.ng\hiecat4i.nd\Default.wnd =5.81 Input Parameters: Directional Procedure All Heights Building (Ch 27 Part 1) Rz Basic Wind Speed(V) = 110.00 mph qz Press Press Structural Category = II Exposure Category. = C Natural Frequency = N/A Flexible Structure = No +/-GCpi Importance Factor = 1.00 Kd Directional Factor = 0.85 0.80 Alpha = 9.50 Zg = 900.00 ft At = 0.11 Bt = 1.00 13.41 Am = 0.15 BM = 0.65 8.25 Cc = 0.20 1 - 500.00 ft Epsilon = 0.20 Zmin = 15.00 ft Pitch of Roof = 10 : 12 Slope of Roof(Theta) = 39.81 Deg h: Mean Roof Ht = 15.46 ft Type of Roof = GABLED 1.00 RHt: Ridge Ht = 20.67 ft Eht: Eave Height = 10.25 ft OH: Roof Overhang at Eave= 2.50 ft Overhead Type = Overhang 0.80 Bldg Length Along Ridge = 32.00 ft Bldg Width Across Ridge= 25.00 ft Gust Factor Calculations Gust Factor Category 1 Rigid Structures - Simplified Method Gustl: For Rigid Structures (Nat. Freq.>1 Hz) use 0.85 = 0.85 Gust Factor. Category II Ricid Structures - Complete Analysis Zm: 0.6*Ht = 15.00 ft lzm: Cc*(33/Zm)^0.167 = 0.23 Lzm: 1*(Zm/33)^Epsilon = 427.06 ft Q: (1/(1+0.63*((B+Ht)/Lzm)^0.63))^0.5 = 0.94 Gust2: 0.925*((1+1.7*lzm*3.4*Q)/(1+1.7*3.4*lzm)) = 0.89 Gust Factor Summary Not a Flexible Structure use the Lessor of Gustl or Gust2 = 0.85 Table 26.11-1 Internal Pressure Coefficients for Buildings, GCpi GCPi Internal Pressure Coefficient = +/-0.18 Wind Pressurs Main Wind Force Resisting System (MWFRS) - Ref Figure 27.4-1 Kh: 2.01*(Ht/Zg)^(2/Alpha) = 0.89 Kht: Topographic Factor (Figure 6-4) = 1.00 Qh: .00256*(V)^2*I*Kh*Kht*Kd - 14.01 psf Cpww: Windward Wall Cp(Ref Fig 6-6) = 0.80 Roof Area = 1249.65 ft^2 Reduction Factor based on Roof Area = 0.80 MWFRS-Wall Pressures for Wind Normal to 32 ft Wall (Normal to Ridge) All pressures shown are based upon ASD Design, wits.', a Load Factor of .6 Wall CP Pressure Pressure --------------- ------ +GCpi (psf) ----------- -GCpi (psf) Leeward Wall -0.50 -8.48 ----------- -3.43 Side Walls -0.70 -10.86 =5.81 Wall Elev Rz Rzt Cp qz Press Press Total ------------------------------------------------------------------- £t psf +GCpi -GCpi +/-GCpi Windward 10.25 0.85 1.00 0.80 13.41 6.60 11.64 15.07 Windward 9.25 0.85 1.00 0.80 13.41 6.60 11.64 15.07 ' Windward 8.25 0.85 1.00 0.80 13.41 6.60 11.64 15.07 Windward 7.25 0.85 1.00 0.80 13.41 6.60 11.64 15.07 Windward 6.25 0.85 1.00 0.80 13.41 6.60 11.64 15.07 Windward 5.25 0.85 1.00 0.80 13.41 6.60 11.64 15.07 Windward 4.25 0.85 1.00 0.80 13.41 6.60 11.64 15.07 Windward 3.25 0.85 1.00 0.80 13.41 6.60 11.64 15.07 Windward 2.25 0.85 1.00 0.80 13.41 6.60 11.64 15.07 Windward 1.25 0.85 1.00 0.80 13.41 6.60 11.64 15.07 Windward 0.25 0.85 1.00 0.80 13.41 6.60 11.64 15.07 18/34 2 Roof Location ---------------------------------- Windward - Min Cp Windward - Max Cp Leeward Norm to Ridge Overhang Top (Windward) Overhang Top (Leeward) Overhang Bot (Windward only) BUTTE COUNTY BUILDING DIVISION APPROVE® Cp Pressure Pressure. +GCpi(psf)-GCpi(psf) ----------------------------------- -0.10 -3.71 1.33 0.32 1.29 6.33 -0.60 -9.67 -4.62 -0.10 -1.19 -1.19 -0.60 -7.14 -7.14 0.80 9.12 9.12 Normal to Ridge - Base Reactions - Walls+Roof -GCpi Description Press Area F: ---------------------------------------------- psf ft^2 Rip Leeward Wall -3.43 328 .00 Side Wall -5.81 256 -1.49 Side Wall -5.81 256 1.49 Windward Wall 11.64 32 .00 Windward Wall 11.64 32 .00 Windward Wall 11.64 32 .00 Windward Wall 11.64 32 .00 Windward Wall 11.64 32 .00 Windward Wall 11.64 32 .00 Windward Wall 11.64 32 .00 Windward Wall 11.64 32 .00 Windward Wall 11.64 32 .00 Windward Wall 11.64 32 .00 Windward Wall 11.64 8 .00 Roof Windward 6.33 521 .00 Roof Leeward -4.62 521 .00 OH Top Windward -1.19 104 .00 OH Top Leeward -7.14 104 .00 OH Bot Windward 9.12 104 .00 Side Wall -5.81 130 -0.76 Side Wall ---------------------------------------------- -5.81 130 0.76 Total .00 2783 .00 Fy Fz Mx NY Mz Rip Rip R -ft A -ft R -ft -------------------------------------- 1.13 .00 5.8 .0 .0 .00 .00 .0 7.6. .0 .00 .00 .0 -7.6 .0 0.37 .00 3.6 .0 .0 0.37 .00 3.3 .0 .0 0.37 .00 2.9 .0 .0 0.37 .00 2.5 .0 .0 0.37 .00 2.1 .0 .0 0.37 .00 1.8 .0 .0 0.37 .00 1.4 .0 .0 0.37 .00 1.0 .0 .0 0.37 .00 0.7 .0 .0 0.37 .00 0.3 .0 .0 0.09 .00 0.0 .0 .0 2.11 -2.53 16.8 .0 .0 1.54 1.85 12.3 .0 .0 -0.08 0.10 0.6 .0 .0 0.48 0.57 -3.5 .0 .0 -0.61 0.73 4.4 .0 .0 .00 .00 .0 10.4 .0 .00 -------------------------- .00 .0 -10.4 .0 8.38 0.71 56.0 ------------ .0 .0 Notes - Normal to Ridge Note (1) Per Fig 27.4-1 Note 7, Since Theta > 10 Deg base calcs on Mean Ht Note (2) Wall 6 Roof Pressures = Qh*(G*Cp - GCPi) Note (3) +GCpi = Positive Internal Bldg Press, -GCPi = Negative Internal Bldg Press Note (4) Total Pressure = Leeward Press + Windward Press (For + or - GCPi) Note (5) Ref Fig 27.4-1, Normal to Ridge (Theta>=10), Theta= 39.8 Deg, h/1= 0.48 Note (6) No internal pressure considered (GCpi = 0) for Overhang Note (7) Overhang bottom based upon windward wall Cp and GCpi = 0. Note (8) X= Along Building ridge, Y = Normal to Building Ridge, Z = Vertical Note (9) MIN = Minimum pressures on Walls = 9.6 psf and Roof - 4.8 psf Note (10) Area* = Area of the surface projected onto a vertical plane normal to wind. METERS -Wall Pressures for Wind Normal to 25 ft wall (Along Ridge) Al.). pressures shown are based upon ASD COSir_.r:, with a ].,oa;i FaCtOr .c" .6 Wall Cp Pressure Pressure --------------- ------ +GCpi (psf) ----------- -GCpi (psf) ----------- Leeward Wall -0.44 -7.81 -2.77 Side Walls -0.70 -10.86 -5.81 Wall Elev Rz Rzt Cp qz Press Press Total ---------------------7--------------------------------------------- ft psf +GCpi -GCpi +/-GCpi Windward 20.67 0.93 1.00 0.80 14.76 7.52 12.56 15.33 Windward 10.25 0.85 1.00 0.80 13.41 6.60 11.64 14.41 Windward 9.25 0.85 1.00 0.80 13.41 6.60 11.64 14.41 Windward 8.25 0.85 1.00 0.80 13.41 6.60 11.64 14.41 Windward 7.25 0.85 1.00 0.80 13.41 6.60 11.64 14.41 Windward 6.25 0.85 1.00 0.80 13.41 6.60 11.64 14.41 Windward 5.25 0.85 1.00 0.80 13.41 6.60 11.64 14.41 Windward 4.25 0.85 1.00 0.80 13.41 .6.60 11.64 14.41 Windward 3.25 0.85 1.00 0.80 13.41 6.60 11.64 14.41 Windward 2.25 0.85 1.00 0.80 13.41 6.60 11.64 14.41 Windward 1.25 0.85 1.00 0.80 13.41 6.60 11.64 14.41 Windward 0.25 0.85 1.00 0.80 13.41 6.60 11.64 14.41 19/34 Roof - Dist from Windward Edge --------------------------------- Roof: 0.0 ft to 7.7 ft Roof: 7.7 ft to 15.5 ft Roof: 15.5 ft to 30.9 ft Roof: 30.9 ft to 32.0 ft OH Top : 0.0 ft to 7.7 ft Overhang Top 7.7 ft to 15.5 ft Overhang Top 15.5 ft to 30.9 ft Overhang Top 30.9 ft to 32.0 ft BUTTE COUNTY BUILDING DIVISION APPROVE® Cp Pressure Pressure +GCpi(psf)-GCpi(psf) ----------------------------- -0.90 -13.24 -8.20 -0.90 -13.24 -8.20 -0.50 -8.48 -3.43 -0.30 -6.09 -1.05 -0.90 -15.76 -15.76 -0.90 -15.76 -15.76 -0.50 -11.00 -11.00 -0.30 -8.62 -8.62 Along Ridge - Base Reactions - Walls+Roof +GCpi Description Press Area Fx --------------------------------------------- psf ft^2 Rip Leeward Wall -7.81 256 2.00 Side Wall -10.86 328 .00 Side wall -10.86 328 .00 Windward Wall 6.60 25 0.16 Windward Wall 6.60 25 0.16 Windward wall 6.60 25 0.16 Windward Wall 6.60 25 0.16 Windward Wall 6.60 25 0.16 Windward Wall 6.60 25 0.16 Windward Wall 6.60 25 0.16 Windward Wall 6.60 25 0.16 Windward Wall 6.60 25 0.16 Windward Wall 6.60 25 0.16 Windward Wall 6.60 6 0.04 Roof (0 to h/2) -13.24 126 .00 Roof (0 to h/2) -13.24 126 .00 OH Top -15.76 25 .00 OH Top -15.76 25 .00 Roof (h/2 to h) -13.24 126 .00 Roof (h/2 to h) -13.24 126 .00 OH Top -15.76 25 .00 OH Top -15.76 25 .00 Roof (h to 2h) -8.48 252 .00 Roof (h to 2h) -8.48 252 .00 OH Top -11.00 50 .00 OH Top -11.00 50 .00 Roof (>2h) -6.09 18 .00 Roof (>2h) -6.09 18 .00 OH Top -8.62 4 .00 OH Top -8.62 4 .00 Leeward wall -7.81 130 1.02 Windward Wall 7.52 130 0.98 --------------------------------------------- Total .00 2679 5.69 Fy Ft Mx My Mz Rip Rip R -ft R -ft R -ft -------------------------------------- .00 .00 .0 -10.3 .0 3.56 .00 18.3 .0 .0 -3.56 .00 -18.3 .0 .0 .00 .00 .0 -1.6 .0 .00 .00 .0 -1.4 .0 .00 .00 .0 -1.3 .0 .00 .00 .0 -1.1 .0 .00 .00 .0 -0.9 .0 .00 .00 .0 -0.8 .0 .00 .00 .0 -0.6 .0 .00 .00 .0 -0.5 .0 .00 .00 .0 -0.3 .0 .00 .00 .0 -0.1 .0 .00 .00 .0 -0.0 .0 -1.07 1.28 -8.5 -15.5 -12.9 1.07 1.28 8.5 -15.5 12.9 -0.25 0.30 1.9 -3.7 -3.1 0.25 0.30 -1.9 -3.7 3.1 -1.07 1.28 -8.5 -5.6 -4.7 1.07 1.28 8.5 -5.6 4.7 -0.25 0.30 1.9 -1.3 -1.1 0.25 0.30 -1.9 -1.3 1.1 -1.36 1.64 -10.9 11.8 9.8 1.36 1.64 10.9 11.8 -9.8 -0.35 0.43 2.6 3.1 2.5 0.35 0.43 -2.6 3.1 -2.5 -0.07 0.08 -0.5 1.3 1.1 0.07 0.08 0.5 1.3 -1.1 -0.02 0.02 0.1 0.4 0.3 0.02 0.02 -0.1 0.4 -0.3 .00 .00 .0 -14.0 .0 .00 .00 .0 -13.4 .0 .00 10.67 .0 -65.8 .0 Notes - Along Ridge Note (1) OH = Overhang, no internal pressure considered for Overhang (GCpi-0) Note (2) Ref Fig 27.4-1, Parallel to Ridge (All), h/1= 0.48 Note (3) X= Along Building ridge, Y = Normal to Building Ridge, Z = Vertical Note (4) MIN = Minimum pressures on Walls = 9.6 psf and Roof = 4.8 psf Note (5) Area' = Area of the surface projected onto a vertical plane normal to wind. Total Base Reaction Summary Notes Applying to MWFRS Reactions: Note (1) Per Fig 27.4-1, Note 9, Use greater of Shear calculated with or without roof.. Note (2) X- Along Building ridge, Y = Normal to Building Ridge, Z = Vertical 20/34 Description FX FY Fz Mx My Hz Rip Kip Rip R -ft R -ft R -ft -----------------------------7-------------------------------------------------------- Normal to Ridge walls+Roof +GCpi .0 6.7 6.7 42.7 .0 .0 Normal to Ridge Walls Only +GCpi .0 4.9 .0 25.3 .0 .0 Normal to Ridge Walls+Roof -GCpi .0 8.4 0.7 56.0 .0 .0 Normal to Ridge Walls Only -GCpi .0 4.9 .0 25.3 .0 .0 Normal to Ridge Walls+Roof MIN .0 7.0 .0 71.5 .0 .0 Along Ridge Walls+Roof +GCpi 5.7 .0 10.7 .0 -65.8 .0 Along Ridge Walls Only +GCpi 5.7 .0 .0 .0 -46.3 .0 Along Ridge Walls+Roof -GCpi 5.7 .0 6.6 .0 -65.8 .0' Along Ridge Walls Only -GCpi 5.7 .0 .0 .0 -46.3 .0 Along Ridge Walls+Roof MIN 3.7 .0 .0 .0 -29.8 .0 Notes Applying to MWFRS Reactions: Note (1) Per Fig 27.4-1, Note 9, Use greater of Shear calculated with or without roof.. Note (2) X- Along Building ridge, Y = Normal to Building Ridge, Z = Vertical 20/34 BUTTE COUNTY BUILDING DIVISION APPROVED Note (3) MIN = Minimum pressures on Walls = 9.6 psf.and Roof = 4.8 psf Note (4) MIN areais the area of the surface onto a vertical plane normal to wind. Note (5) Total Roof Area (incl OH Top) = 1249.65 sq. ft kil 21/34 ' PZ5E, INC - 5TRUCTURAL ENGINEERS WIND FORCE LATERAL DESIGN: FRnNT- RFAR nIRFrTInN Level Diaphragm Story Shear (lbs) Shear Top of Roof 1st floor top plate 4970 1st floor 4970 I FFT - RIGHT DIRFr'TinN Level Diaphragm Story Shear (lbs) Shear Top of Roof 1st floor top plate 6715 1st floor 6715 I LATERAL GOVERNING CONDITIONS FRONT - REAR DIRECTION: Roof Diaphragm = 6387 lbs Diaphragm load, w = 266 plf Story Shear, V = 5686 lbs Seismic Governs Seismic Governs LEFT -RIGHT DIRECTION: Roof Diaphragm = 6715 lbs Wind Governs Diaphragm load, w = 210 plf Story Shear, V = 6715 lbs Wind Governs 22/34 BUTTE COUNTY BUILDING DIVISION APPROVED r 266 plf 210 plf Left 24.00 ft' Front ROOF t Right PZSE, INC - STRUCTURAL ENGINEERS LATERAL DESIGN FRONT -BACK FIRST FLOOR: GRIDLINE 1 Story shear, V 5686 lbs Plate height 9.25 ft Total wall length 31.50 ft Tributary width 12.00 ft 2/3 dead load 186 plf Total SW lengths 9.50 ft Total width 24.00 ft Min SW Length 3.50 ft Gridline shear 2843 lbs Wall shear 299 plf Roof shear 90 plf Net shear 209 plf 1000 wall open wall open wall open wall open wall so wall open wall open Lengths (ft) 0.00 11.00 6.00 4.00 3.50 7.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Force at Rt ends of wall/open'g (lbs) 0 -993 261 -100 632 0 0 %openwallopen 0 00 0 0 0 0 0 SW height LION 9 9 9 9 9 9 9 9 Shear wall Type 2 2 1000 0 Story shear, V 5686 lbs Tributary width 2100 �a2450'� 3i 80'y 3150 31 SOr3150 3150.'- '51 50.x"3150 31.501 .p 31.5D 51.50' X31 2.g �.000-2000r. so 24.00 ft Therefore use: 24-16d's at splice FIRST FLOOR: GRIDLINE 2 wall Story shear, V 5686 lbs Tributary width 12.00 ft Total width 24.00 ft Gridline shear 2843 lbs Ftg: V-0" x V-6" w/ (1) #4 T& B Plate height 9.25 ft Total wall length 32.00 ft 2/3 dead load 186 plf Total SW lengths 20.00 ft Min SW Length 10.00 ft Holdown Tension = 2039 lbs Wall shear 142 plf Roof shear 89 plf Net shear 53 plf 200 .�. .:.. �. - - _ Y' __ 0 •l..1t aav :.fit .:it:.�-r,,3=r �.:aecr?iii-r- '�-�s"=rkz"�ai'i s -200 ,5pi0 .700 mow"}"Ft1210D 3100Y,x3200,.',320�0_t��.ir32.�„ew3200 r3200`"`*532t00 ;'320D 3400 3200}+"03200 3200 400 �� Therefore use: 24-16d's at splice Ftg: 1'-0" x 1'-6" w/ (1) #4 T & B BUTTE COUNTY BUILDING DIVISION APP'OVE® 23/34 Holdown Tension = 997 lbs 5/8" 0 ROD d Symbol 5/8" 0 ROD p Symbol wall open wall open wall open wall open wall open wall open wall open wall open Lengths (ft) 0.00 7.00 10.00 4.00 10.00 1.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Force at Rt ends of wall/open'g (Ibs) 0 -622 -89 -444 89 0 0 0 0 0 0 0 0 0 0 0 SW height LION 9 9 9 9 9 9 9 9 Shear wall Type 1 1 1 200 .�. .:.. �. - - _ Y' __ 0 •l..1t aav :.fit .:it:.�-r,,3=r �.:aecr?iii-r- '�-�s"=rkz"�ai'i s -200 ,5pi0 .700 mow"}"Ft1210D 3100Y,x3200,.',320�0_t��.ir32.�„ew3200 r3200`"`*532t00 ;'320D 3400 3200}+"03200 3200 400 �� Therefore use: 24-16d's at splice Ftg: 1'-0" x 1'-6" w/ (1) #4 T & B BUTTE COUNTY BUILDING DIVISION APP'OVE® 23/34 Holdown Tension = 997 lbs 5/8" 0 ROD d Symbol 5/8" 0 ROD p Symbol FZSE,INC- STRUCTURALENGINEERS FIRST FLOOR: GRIDLINE A Story shear, V 6715 Ills Tributary width 16 ft Total width 32 ft LATERAL DESIGN FRONT -BACK Plate height 9.25 ft Total wall length 22.50 ft 2/3 dead load 186 plf Total SW lengths 6.50 ft Min SW Length 3.25 ft Wall shear 517 plf Roof shear 149 plf Net shear 367 Of line shear 3358 lbs rk.•-'� + c. L .;� z yr o T. 6:rn '.'S'l. ,n-�r<rn .+'T''3fls ''.+...^°' r'+i-rs`•'--}+:n '-..'�c .` ,�.+.,:14r..�, 5 w�.�r -1000 • iiti a25'p .:.. '.- +22.50 {� S0 522.50 22c5 !� ', 22,50 22.SD�ir 22 50'�"�+ 22.50 is 22.50 )t- r�22 SD �Sxt' 22.50 #22.SO`�22.50 '• wall open wall open wall open wall open wall open wall open wall open wall of the (ft) 3.25 16.00 3.25 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 e at Rt ends of 563 -711 0 0 0 0 0 0 0 0 0 0 0 0 0 'open'g (lbs) 1194 -1194 0 0 0 0 0 0 0 0 0 0 0 0 0 might LION 9 9 9 9 9 9 9 9 r wall Type 4 4 2000 1000'`'G�' ♦• t�} ,fix •, v �, >r F }. rk.•-'� + c. L .;� z yr o T. 6:rn '.'S'l. ,n-�r<rn .+'T''3fls ''.+...^°' r'+i-rs`•'--}+:n '-..'�c .` ,�.+.,:14r..�, 5 w�.�r -1000 • iiti a25'p .:.. '.- +22.50 {� S0 522.50 22c5 !� ', 22,50 22.SD�ir 22 50'�"�+ 22.50 is 22.50 )t- r�22 SD �Sxt' 22.50 #22.SO`�22.50 '• 50 -2000 �' „e a rr'�, Y.•• i r-. r+�.{ brEN�._ '4"s. a`I'i i57 ..c:+:1F,.f . »?Tn..�T''a •d'r ,,7ta:`.,+c _M1G Li.+ �.J-'-1"F,`t ?'t.�?, v^t ",.gym 0.00 0.00 0.00 0.00 0.00 0.00 0 e at Rt ends of Therefore use: 24-16d's at splice FIRST FLOOR: GRIDLINE B wall Story shear, V 6715 lbs Tributary width 12 ft Total width 32 ft Gridline shear 2518 lbs Ftg: 1'-0" x 1'-6" w/ (1) #4 T & B Plate height 9.25 ft Total wall length 21.75 ft 2/3 dead load 186 plf Total SW lengths 10.75 ft Min SW Length 4.75 ft Holdown Tension = 5281 lbs Wall shear 234 plf Roof shear 116 plf Net shear 118 plf 1000 wall open wall open wall open wall open wall open wall open wall open wall of the (ft) 4.75 11.00 6.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 e at Rt ends of fopen'g (Ibs) 563 -711 0 0 0 0 0 0 0 0 0 0 0 0 0 ieight UON 9 9 9 9 9 9 9 9 r wall Type 1 1 1 1000 500 t:. t• .{ "l. 0�-'_ { Y A.' G•4 N . 500 475 575_;_1i.75;'_21.75 2`1.7F5:'-`2175{ 21.75 21.75h 2175' 2175Y,�?:.2175it"�2t75 '(21.75 2175- 2175`.- 2775 �€ �'9�, K -1000 - dY. �. S.i. �i'.'t!+tn.`» c" lrx�v_+,43r ^a«1..:�i Therefore use: 24-16d's at splice Ftg: 1'-0" x 1'-6" w/ (1) #4 T & B BUTTE COUNTY BUILDING DIVISION APPROVED 24/34 Holdown Tension = 2233 Ills STHD14 • Symbol 5/8" � ROD tt Symbol Title: DOVBUSH LOG CABIN / Job # 2016-09434 Dsgnr: P.K. ZACHER, S.E. Date: 5:01 PM, 30 AUG 16 i=0sil=:n� scription : RESIDENCE / Scope: STRUCTURAL ENGINEERING STRUtTURAI ENGINEERS Rev: 580000 User: KW -0602844, Ver 5.8.0,1 -Nov -2006 Horizontal Plywood Diaphragm Page 1 (c)198&2006 ENERCALC Engineering Software Dovbush Log Cabin.emCalculations Description ROOF General Information Framing Thickness Grade Nail Size North-South Length 32.00 ft Diaphrgm Weight 0.00 psf East-West Length 24.00 ft Seismic Factor in 1.0000 Nort-South Chord 32.00 ft Diaphragm is Unblocked 1/2" East-West Chord 24.00 ft Blocking Direction 265.0 North-South Boundary Loads Acting North & South 3x 1/2" Grade C-D,C-C # 1 269.00 #/ft from 0.000 ft to 24.000 ft 3rd zone # 2 #/ft from 0.000ft to 0.000 ft BUILDING DIVISION # 3 #/ft from 0.000 ft to 0.000 ft APPROVED �\' # 4 #/ft from 0.000 ft to 0.000 ft X11 1 v Boundary Loads Acting East & West 2x 1/2" Grade C-D,C-C # 1 216.00 #/ft from 0.000 ft to 32.000 ft 2nd zone # 2 #/ft from 0.000 ft to 0.000 ft 2.5,4,12 # 3 #/ft from 0.000ft to 0.000 ft 1/2" # 4 #/ft from 0.000 ft to 0.000 ft 0.00 North & South Walls Design Data & Nailing Requirements East & West Walls Design Data & Nailing Requirements 111 Framing Framing Thickness Grade Nail Size Spacing Value Distance in in in in #/ft ft At North Wall 3x 1/2" Grade C-D,C-C 8d 2,3,12 265.0 0.00 2nd zone 3x 1/2" Grade C-D,C-C 8d 2.5,4,12 265.0 0.00 3rd zone 2x 1/2" Grade C-D,C-C 8d 4,6,12 240.0 0.00 Center zone 2x 1/2" GradeC-D,C-C 8d 6,6,12 240.0 3rd zone 3rd zone 2x 1/2" Grade C-D,C-C 8d 4,6,12 240.0 0.00 2nd zone 3x 1/2" Grade C-D,C-C 8d 2.5,4,12 265.0 0.00 At South Wall 3x 1/2" Grade C-D,C-C 8d 2,3,12 265.0 0.00 East & West Walls Design Data & Nailing Requirements 111 Framing Thickness Grade Nail Size Spacing Value Distance in in #/ft ft At West Wall 3x 1/2" Grade C-D,C-C 8d 2,3,12 200.0 0.00 2nd zone 3x 1/2" Grade C-D,C-C 8d 2.5,4,12 200.0 0.00 3rd zone 2x 1/2" Grade C-D,C-C 8d 4,6,12 180.0 0.00 Center zone 2x 1/2" Grade C-D,C-C 8d 6,6,12 180.0 3rd zone 2x 1/2" Grade C-D,C-C 8d 4,6,12 180.0 0.00 2nd zone 3x 1/2" Grade C-D,C-C 8d 2.5,4,12 200.0 0.00 At East Wall 3x 1/2" Grade C-D,C-C 8d 2,3,12 200.0 0.00 Shear & Chord Forces Diaphragm Shears... North South West East Total Shear 3,456.0 lbs 3,456.0 lbs 3,228.0 lbs 3,228.0 lbs Shear per Foot 144.00 #/ft 144.00 #/ft 100.88 #/ft 100.88 #/ft Chord Forces... @ 1/4' Length 451.5 lbs 859.4 lbs @ 1/2' Length 605.3 lbs 1,152.0 lbs @ 3/4 ' Length 456.3 lbs 868.6 lbs Length / Width Ratio 1.333 25/34 Title: DOVBUSH LOG CABIN Job # 2016-09434 Dsgnr: P.K. ZACHER, S.E. Date: 5:01 PM, 30 AUG 16 (� escription : RESIDENCE STRUCTURAL ENGINEERS Scope: STRUCTURAL ENGINEERING Rev: 580004 User: KW.0602844, Ver 5.8.0, 1 -Nov -2006 plywood Shear Wall & Footing Page 1 (01983-2006 ENERCALC Engineering Software Dovbush Log Cabin.em:Calwlations Description FIRST FLOOR: GRIDLINE 1 (for uplift calculation only) General Information Base allowables are user defined j # Plywood Layers 1 Wall Length 3.500 ft End Post Dimension 3.50 in Plywood Grade Grade C -D Wall Height 10.250 ft Seismic Factor 0.000 Nail Size 8d Wall Weight 0.000 psf Nominal Sill Thick. 2.00 Thickness 3/8" Ht / Length 2.929 Stud Spacing 16.00 in Loads Vertical Loads... Overburden Load over Footing 100.00 psf Point Load # 1 0.00 lbs at 0.00 ft Point Load # 2 0.00 lbs at 0.00 ft Point Load # 3 0.00 lbs at 0.00 ft BUTTE COUNTY Uniform Load # 1 100.00 #/ft 0.00 ft to 3.50 ft BUILDING Uniform Load # 2 0.00 #/ft 0.00 ft to 0.00 ft DIVISION Lateral Loads... AP®RO\ /CC® Uniform Shear @Top of Wall 216.00 #/ft 3.500 ft = 756.00 lbs 1 �/ Uniform Shear @ Top of Wall 0.00 #/ft 3.500 ft = 0.00 lbs Strut Force Applied @ Top of Wall 0.00 lbs Strut Force Applied @ Top of Wall 0.00 lbs Moment Applied @ Top of Wall 0.00 ft-# Footing Past Left Edge of Wall 7.000 ft Concrete Weight 145.00 pcf Wall Length 3.500 ft Rebar Cover 3.00 in Past Right Edge of Wall 7.000 ft fc 2,500.00 psi Footing Length 17.500 ft Fy 40,000.00 psi Footing Width 1.00 ft Min. Steel As % 0.00000 Footing Thickness 18.00 in Design OK Wall Summary... Using 3/8" Thick Grade C -D on 1 side/s, Nailing is 8d at 6 in @ Edges, 8d at 12 in @ Field Applied Shear = 216.0#/ft, Capacity = 260.000#/ft -> OK Wall Overturning = 7,749.Oft-#, Resisting Moment = 612.5ft-#, End Uplift = 2,039.00Ibs Max. Soil Pressures: @ Left = 511.5psf, @ Right = 511.5psf Sill Bolting: 1/2" Bolts @ 46.92in, 5/8" Bolts @ 48.00in, 3/4" Bolts @ 48.00in 26/34 Title: DOVBUSH LOG CABIN Job # 2016-09434 =ZSE: Dsgnr: P.K. ZACHER, S.E. Date: 5:01 PM, 30 AUG 16 IniDe scription : RESIDENCE STRUtTURAI ENGINEERS Scope: STRUCTURAL ENGINEERING user: icw-06,028", Ver 5.8.0,1 -Nov -2006 Plywood Shear Wall & Footing Page 1 r (c)1963-2006 ENERCALC Engineering Software Dovbush Log Cabin.ecw:Calculations Description FIRST FLOOR: GRIDLINE 2 (for uplift calculation only) General Information Base allowables are user defined h # Plywood Layers 1 Wall Length 10.000 ft End Post Dimension 3.50 in Plywood Grade Grade C -D Wall Height 10.250 ft Seismic Factor 0.000 Nail Size 8d Wall Weight 0.000 psf Nominal Sill Thick. 2.00 Thickness 3/8" Ht/Length 1.025 Stud Spacing 16.00 in Loads Vertical Loads... Overburden Load over Footing 100.00 psf Point Load # 1 0.00 lbs at 0.00 ft Point Load # 2 0.00 lbs at 0.00 ft Point Load # 3 0.00 lbs at 0.00 ft BUTTE COUNTY Uniform Load # 1 100.00 #/ft 0.00 ft to 10.00 ft BUILDING DIVISION Uniform Load # 2 0.00 #/ft 0.00 ft to 0.00 ft ry ^ Lateral Loads... �+ APPROVED r � ®` V,� Uniform Shear @ Top of Wall 146.00 #/ft 10.000ft = 1,460.00 lbs Uniform Shear @ Top of Wall 0.00 #/ft 10.000 ft = 0.00 lbs Strut Force Applied @ Top of Wall 0.00 lbs Strut Force Applied @ Top of Wall 0.00 lbs Moment Applied @ Top of Wall 0.00 ft-# Footing Past Left Edge of Wall 7.000 ft Concrete Weight 145.00 pcf Wall Length 10.000 ft Rebar Cover 3.00 in Past Right Edge of Wall 7.000 ft fc 2,500.00 psi Footing Length 24.000 ft Fy 40,000.00 psi Footing Width 1.00 ft Min. Steel As % 0.00000 Footing Thickness 18.00 in Design OK Wall Summary... Using 3/8" Thick Grade C -D on 1 side/s, Nailing is 8d at 6 in @ Edges, 8d at 12 in @ Field Applied Shear = 146.0#/ft, Capacity = 260.000#/ft -> OK Wall Overturning = 14,965.Oft-#, Resisting Moment = 5,000.Oft-#, End Uplift = 996.50lbs Max. Soil Pressures: @ Left = 537.9psf, @ Right = 537.9psf Sill Bolting: 1/2" Bolts @ 48.00in, 5/8" Bolts @ 48.00in, 3/4" Bolts @ 48.00in 27/34 Title: DOVBUSH LOG CABIN Job # 2016-09434 Dsgnr: P.K. ZACHER, S.E. Date: 5:01 PM, 30 AUG 16 scription : RESIDENCE STRUCTURAL ENGINEERS Scope : STRUCTURAL ENGINEERING Rev: 580004 User: KW0602844, Ver 5.8.0, I -Nov -2006 plywood Shear Wall & Footing Page 1 (c)1983-2006 ENERCALC Engineering Software Dovbush Log Cabin.ecw:Calculations Description FIRST FLOOR: GRIDLINE 3 (for uplift calculation only) A General Information Base allowables are user defined # Plywood Layers 1 Wall Length 3.250 ft Lno Post Dimension 3.50 in Plywood Grade Grade C -D Wall Height 10.250 ft Seismic Factor 0.000 Nail Size 8d Wall Weight 0.000 psf Nominal Sill Thick. 2.00 Thickness 3/8" Ht / Length 3.154 Stud Spacing 16.00 in Loads Vertical Loads... Overburden Load over Footing 100.00 psf Point Load # 1 0.00 lbs at 0.00 ft Point Load # 2 0.00 lbs at 0.00 ft BUTTE COUNTY Point Load # 3 0.00 lbs at 0.00 ft BUILDING DIVISION Uniform Load # 1 100.00 #/ft 0.00 ft to 3.25 ft Uniform Load # 2 0.00 #/ft 0.00 ft to 0.00 ft APPROVED \®®R O\�/ E Lateral Loads... /'�]' j— Uniform Shear @ Top of Wall 531.00 #/ft 3.250 ft = 1,725.75 lbs Uniform Shear @ Top of Wall 0.00 #/ft 3.250 ft = 0.00 lbs Strut Force Applied @ Top of Wall 0.00 lbs Strut Force Applied @ Top of Wall 0.00 lbs Moment Applied @ Top of Wall 0.00 ft-# Footing Past Left Edge of Wall 6.000 ft Concrete Weight 145.00 pcf Wall Length 3.250 ft Rebar Cover 3.00 in Past Right Edge of Wall 6.000 ft fc 2,500.00 psi Footing Length 15.250 ft Fy 40,000.00 psi Footing Width 1.00 ft Min. Steel As % 0.00000 Footing Thickness 18.00 in Design OK Wall Summary... Using 3/8" Thick Grade C -D on 1 side/s, Nailing is 8d at 2 in @ Edges, 8d at 12 in @ Field Applied Shear = 531.0#/ft, Capacity = 640.000#/ft -> OK Wall Overturning = 17,688.9ft-#, Resisting Moment = 528.1ft-#, End Uplift = 5,280.25lbs Max. Soil Pressures: @ Left = 930.9psf, @ Right = 930.9psf Sill Bolting: 1/2" Bolts @ 19.09in, 5/8" Bolts @ 29.76in, 3/4" Bolts @ 42.08in 28/34 Project Title: Engineer: Project ID: RNISMw(^� Protect Descr: I ' i STRUCTURAL ENGINEERS .5 ,•••r �• g ? • cs a F k.� ' File = PIKSEIPROJECT FILE JVood Column 1 4 4_f..+4•, y; KW -06002844- Licena Description : STUD: CRIPPLE WALL BELOW LOG WALL @ 16" O.C. b , wirrium Reactions', ; Note: Only non -zero reactions are listed 32/34 X -X Axis Reaction Y -Y Axis Reaction Axial Reaction Load Combination @ Base @ Top @ Base @ Top @ Base L Only k k 0.080 k S Only k k k W Only k 0.010 0.010 k k E Only k k k H Only k k k +D+H k k 0.872 k +D+L+H k k 0.952 k +D+Lr+H k k 1.192 k +O+S+H k k 0.872 k +D+0.750Lr+0.750L+H k k 1.172 k +D+0.750L+0.750S+H k k 0.932 k +0+0.70E+H k k I 0.872 k +D+0.750L+0.750S+0.5250E+H k k 0.932 k +0.60D+0.70E+0.60H k k 0.523 k [MMazimum Deflections for Load Combinatiorfs' � <.. r Load Combination Max. X -X Deflection Distance Max. Y -Y Deflection Distance D Only 0.0000 in 0.000 ft 0.000 in 0.000 It BUTTE COUNTY Lr Only 0.0000 in 0.000 ft 0.000 in 0.000 ft LOnly 0.0000 in 0.000 it 0.000 in 0.000 ft BUILDING DIVISION S Only W Onry 0.0000 in 0.0000 in 0.000 it 0.000 ft 0.000 in 0.001 in 0.000 ft 2.013 ft AP 1 F ®VE E Only 0.0000 in 0.000 ft 0.000 in 0.000 it H Only 0.0000 in 0.000 it 0.000 in 0.000 it +D+0.750L+0.750S+0.750W 0.0000 in 0.000 ft 0.001 in 2.013 It +D+Lr 0.0000 in 0.000 It 0.000 in 0.000 it +D+S 0.0000 in 0.000 ft 0.000 in 0.000 ft +0+0.750Lr+0.750L 0.0000 in 0.000 it 0.000 in 0.000 ft +D+0.750L+0.750S 0.0000 in 0.000 it 0.000 in 0.000 it +D+W 0.0000 in 0.000 ft 0.001 in 2.013 ft +0+0.70E 0.0000 in 0.000 ft 0.000 in 0.000 ft r +D+0.750Lr+0.750L+0.75OW 0.0000 in 0.000 ft 0.001 in 2.013 it +D+0.750Lr+0.750L+0.5250E 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+0.750L+0.750S+0.5250E 0.0000 in 0.000 it 0.000 in 0.000 ft +0.60D+W 0.0000 in 0.000 ft 0.001 in 2.013 it 40.60D40.70E 0.0000 in 0.000 ft 0.000 in 0.000 it +O+Lr+L+S+W+E+H 0.0000 in 0.000 ft 0.001 in 2.013 it +D+E 0.0000 in 0.000 it 0.000 in 0.000 ft +0.60D+E 0.0000 in 0.000 it 0.000 in 0.000 It 4M.750Lr+0.750L+0.750E 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+0.750L+0.750S+0.750E 0.0000 in 0.000 It 0.000 in 0.000 ft 32/34 Project Title: + r Engineer: Proiect ID: Protect Descr: i. STRUCTURAL ENGINEERS i Description : STUD: CRIPPLE WALL BELOW LOG WALL @ 16' O.C. ¢� %$ketches Y 1.272k M -x Loads ` BUTTE COUNTY BUILDING DIVISION Am 1x FSA■®■®O V E® V t , e 4 Y ■ �_ = 5 2x6 ,� [ 1 LJ Loads are total entered value. Arrows do not reflect absolute direction. r `t t t 4 i . i ' t . i CANTILEVER DIAPHRAGM DESIGN: DESCRIPTION: CANOPY Loading: Controlling Lateral Force (Wind) V = Story Shear due to Wind (W) * Canopy Width / Total Wi W = 6900 lbs Canopy Width = 10 ft Total Width = 34 ft V canopy = 2029 lbs DESIGN SHEATHING Width, b Length, L Top plate height Loading, w Roof diaphragm shear, v Thickness of sheathing Size of nail; 8d etc Nail spacing 10 feet, pressure applied along width, b 32 feet 9 feet. 203 plf 63 plf 15/32 inch 8d 6 inches oc Therefore, use 15/32" CDX with 8d commons at. 6" oc edges, 12" oc field DETERMINE DIAPHRAGM DEFLECTION Diaohraem deflection: Shear deflection, s 0.057 inches Nail slip, n 0.096 inches Total story drift 0.153 inches Allowable story drift 0.540 inches CHORD FORCES AT RE-ENTRANT CORNERS T or C = Vb/2L 317 lbs Therefore, the (3) 16d's at each rafter to truss connection at the top plate is adequate for the Chord Force 34/34 BUTTE COUNTY BUILDING DIVISION APPR®VE® Story Drift OK f=ZSETitle: DOVBUSH LOG CABIN Job # 2016-09434 Dsgnr: P.K. ZACHER, S.E. Date: 5:01 PM, 30 AUG 16 :In� scription : RESIDENCE STRUCTURAL ENGINEERS Scope : STRUCTURAL ENGINEERING Rev: 580004 User: KW-0602844, Ver 5.8.0,1-Nov-2006 Plywood Shear Wall & Footing Page 1 (c)1983-2006 ENERCALC Engineering Software Dovbush Log Cabin.ecw:Calculations Description FIRST FLOOR: GRIDLINE 4 (for uplift calculation only) General Information Base allowables are user defined # Plywood Layers 1 Wall Length 4.750 ft End Post Dimension 3.50 in Plywood Grade Grade C -D Wall Height 10.250 ft Seismic Factor 0.000 Nail Size 8d Wall Weight 0.000 psf Nominal Sill Thick. 2.00 Thickness 3/8" Ht / Length 2.158 Stud Spacing 16.00 in Loads Vertical Loads... Overburden Load over Footing 100.00 psf Point Load # 1 0.00 lbs at 0.00 ft Point Load # 2 0.00 lbs at 0.00 ft Point Load # 3 0.00 lbs at 0.00 ft BUTTE COUNTY Uniform Load # 1 100.00 #/ft Uniform Load # 2 0.00 #/ft 0.00 ft 0.00 ft to to 4.75 ft BUILDING DIVISION 0.00 ft Lateral Loads... APPHO\ /ED Uniform Shear @Top of Wall 241.00 #/ft 4.750 ft = 1,144.75 lbs �/ Uniform Shear @ Top of Wall 0.00 #/ft 4.750 ft = 0.00 lbs Strut Force Applied @ Top of Wall 0.00 lbs Strut Force Applied @ Top of Wall 0.00 lbs Moment Applied @ Top of Wall 0.00 ft-# Footing Past Left Edge of Wall 6.000 ft Concrete Weight 145.00 pcf Wall Length 4.750 ft Rebar Cover 3.00 in Past Right Edge of Wall 6.000 ft fc 2,500.00 psi Footing Length 16.750 ft Fy 40,000.00 psi Footing Width 1.00 ft Min. Steel As % 0.00000 Footing Thickness 18.00 in Design OK Wall Summary... Using 3/8" Thick Grade C -D on 1 side/s, Nailing is 8d at 6 in @ Edges, 8d at 12 in @ Field Applied Shear = 241.0#/ft, Capacity = 260.000#/ft -> OK Wall Overturning = 11,733.7ft-#, Resisting Moment = 1,128.1ft-#, End Uplift = 2,232.75lbs Max. Soil Pressures: @ Left = 633.5psf, @ Right = 633.5psf Sill Bolting: 1/2" Bolts @ 42.05in, 5/8" Bolts @ 48.00in, 3/4" Bolts @ 48.00in 29/34 PZSE,INC- STRUCTURALENGINEERS BUTTE COUNTY BUILDING DIVISION APPROVE® 30/34 STUDWALL LOADING LOCATION: CRIPPLE WALL BELOW LOG WALL Stud Length, L 4 feet Stud spacing, wst„d 12 inches AXIAL LOADING: Dead load roof, D 352 352 plf Live load roof, Lr 320 320 plf Snow load roof, Sr 0 0 plf Dead load floor,Df 40 40 plf Live load floor, Lf 80 80 plf Dead load wall, Dw 480 480 plf D: Dead = 872 plf Lr: Roof Live = 320 plf L: Live = 80 plf S: Snow = 0 plf LATERAL LOADING: Wind Exposure Catagory = C Uniform Lateral Load, w = 20.0 plf Partition Load (5.0 psf), w = 5.0 plf BUTTE COUNTY BUILDING DIVISION APPROVE® 30/34 .ffi. Project Title: + Engineer: Project ID: Protect Descr: STRU(TURALENGINEERS U 8111 File = RIHSEIPROJECT FILES120161obs1Pw*h Log Cabin16 094341ENGRTmbush Log Cabin 6C67 ENERCALC,INC. 1983-2016,Build :6.16.4.12 Ver.6.16.4.12 Description : STUD: CRIPPLE WALL BELOW LOG WALL @ 16" O.C. Code ReferencesBUTTE COUNTY RI 111DING DIVISION Calculations per 2012 NDS, IBC 2012, CBC 2013, ASCE 7-10 ����®` v,�® Load Combinations Used: IBC 2012 General Information Analysis Method : Allowable Stress Design Wood Section Name 2x6 End Fixities Top & Bottom Pinned Wood Grading/Manuf. Graded Lumber Overall Column Height 4.0 ft Wood Member Type Sawn ( Used /or non -slender cakulations ) Wood Species Douglas Fir -Larch Exact Width 1.50 in Allow Stress Modification Factors Wood Grade Stud Exact Depth 5.50 in Cf or Cv for Bending 1.0 Area 8.250 in"2 Cf or Cv for Compression 1.0 Fb - Tension 700.0 psi Fv 180.0 psi Ix 20.797 in 4 Cf or Cv for Tension 1.0 Fb - Compr 700.0 psi Ft 450.0 psi Iy 1.547 in Cm :Wet Use Factor 1.0 Fc - Prll 850.0 psi Density 32.210 pcf Ct : Temperature Factor 1.0 Fc -Perp 625.0 psi Cfu :Flat Use Factor 1.0 E : Modulus of Elasticity ... x x Bending y -y Bending Axial Kf : Built-up columns 1.0 PIDS 15.32 Basic 1,400.0 1,400.0 1,400.0 ksi Use Cr : Repetitive? Yes Minimum 510.0 510.0 Brace condition for deflection (buckling) along columns : X -X (width) axis: Unbraced Length for X -X Axis buckling = 4.0 ft, K =1.0 Y -Y (depth) axis: Unbraced Length for X -X Axis buckling = 4.0 ft, K =1.0 Applied Loads Service loads entered. Load Factors will be applied for calculations. AXIAL LOADS ... Axial Load at 4.0 ft, D = 0.8720, Lr = 0.320, L = 0.080 k BENDING LOADS ... Lat. Uniform Load creating Mx -x, W = 0.0050 k/ft DESIGN SUMMARY Bending & Shear Check Results PASS Max. Axial+Bending Stress Ratio = 0.3906:1 Maximum SERVICE Lateral Load Reactions . . Load Combination +-D+Lr+H Top along Y -Y 0.010 k Bottom along Y -Y 0.010 k Governing NDS Forumla Comp Only, fc/Fc' Top along X -X 0.0 k Bottom along X -X 0.0 k Location of max.above base 0.0 ft Maximum SERVICE Load Lateral Deflections ... At maximum location values are ... Along Y -Y 0.0010 in at 2.013 ft above base Applied Axial 1.192 k for load combination : W Only Applied Mx 0.0 k -ft Applied My 0.0 k -ft Along X -X 0.0 in at 0.0 ft above base Fc: Allowable 369.887 psi for load combination : n/a Other Factors used to calculate allowable stresses ... PASS Maximum Shear Stress Ratio = 0.004209:1 Bendinq Compression Tension Load Combination +D+W Location of max.above base 0.0 ft Applied Design Shear 1.818 psi Allowable Shear 288.0 psi Maximum Reactions Note: Only non -zero reactions are listed. X -X Axis Reaction Y -Y Axis Reaction Axial Reaction Load Combination @ Base @ Top @ Base @ Top @ Base +D+Lr+L+S+W+E+H k 0.010 0.010 k 1.272 k +D+W+H k 0.010 0.010 k 0.872 k +D+0.70E+H' k k 0.872 k +D+0.750Lr+0.750L+0.750W+H k 0.008 0.007 k 1.172 k +0+0.750L+0.750S+0.750W+H k 0.008 0.007 k 0.932 k +0+0.750Lr+0.75OL+0.5250E+H k k 1.172 k +0.60D+W+0.60H k 0.010 0.010 k 0.523 k +0.60D+0.70E+0.60H k k 0.523 k D Only k k 0.872 k Lr Only k k 0.320 k 31/34