HomeMy WebLinkAboutB16-2190 000-000-000y OMP. SHINGLES BUTTE COUNTY SEP 3 0 2016 DEVELOPMENT SERVICES Q1(;`41a0 IE FRONT ELEVATION 1/4" = 1'-0" STUCCO o/ FOAM TRIM LEFT ELEVATION 1/4" = I. CODE ANALYSIS 60VERNIN6 CODES: 2013 GBG, 2013 GRG 2013 CEG, 2013 CPG, 2013 CMG, 2013 CFC, 2013 CALIF. HEALTH G SAFETY CODE AMENDMENTS 2013 CALIF. ENERGY CODE EFFICIENCY STANDARDS, ZONE II 2013 CALIF. ACCE551BILITY REQUIREMENTS AMERICANS w/ DISABILITIES ACT, 2012 EDITION NFPA 101, 2013 0555C OCCUPANCY CROUP: GROUP: U ALLOWABLE HEIGHT AND BUILDING AREAS (TABLE 503) ALLOWABLE AREA: 3,000 S.F. (GBG 406.3.2) ACTUAL FLOOR AREA: 1800 S.F. ALLOWABLE STORY/HEIGHT: (1) STORY / 40'-0" ACTUAL STORY/HEIGHT: (1) STORY / 19'-6" CONSTRUCTION TYPE: TYPE VB AUTOMATIC SPRINKLER: N/A WILDLAND URBAN FIRE INTERFACE: WA ELECTRICAL SYMBOLS SINGLE POLE SWITCH FLUOR. WALL MTD. FIXTURE 3 THREE WAY SWITCH FLUORESCENT FIXT. 6 DUPLEX REGEPT. L` ES ;3 FLUORESCENT FIXTURE 6 220 VOLT OUTLET I=W- PANEL BOARD 6 DUPLEX SPLIT WIRED F'6' - FUEL SAS OUTLET -¢- GLS. MTD. FIXT. H.5'{}- HOSE BIBB WALL MTD. FIXTURE _6FI AUTOMATIC, GARAGE r DOOR OPENER LISTED IN L - ACCORDANCE w/ UL 325, w/ GFI OUTLET ELECTRICAL NOTES: I. ALL 125 VOLT, SINGLE PHASE, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED TAMPER RESISTANT RECEPTACLES. 2. FIXTURES, LAMP HOLDERS AND RECEPTACLES OUTLETS SHALL BE SECURELY SUPPORTED. A FIXTURE THAT WEIGHS MORE THAN III OR EXCEEDS IbIn. IN ANY DIMENSION SHALL NOT BE SUPPORTED BY THE SCREW SHELL OF A LAMP HOLDER PER 2013 GEC SECTION 410.15. (a). OUTLET BOXES SHALL NOT BE USED AS THE SOLE SUPPORT FOR CEILING FANS PER 2013 SECTION 31427 (a 8 d). 3. ALL CARAOE, LAUNDRY ROOM, AND UTILITY ROOM LIGHTING SHALL BE HIGH -EFFICACY AND CONTROLLED BY A MANUAL -ON OCCUPANCY SENSOR. 2 -GOAT STUCCO o/ I" FOAM o/ (2) LAYERS GRADE D BLDG. PAPER OR EQ. PER 'WESTERN I-KOTE' SYSTEM OR EQ. (UER ER 582) 4" GLR. TO EARTH AND 2" TO GONG. FOR WEEP SCREED REAR ELEVATION 5HEARWALL 50HEDULE: SYMBOL: SHEARWALL: Q3/e° GDX PLYWD. OR OSB GDX PLYWD. OR OSB 4 w/ Bd'S a 4", 12" O.G. w/ Q 4x STUDS a ADJ. PANEL SPLICES %" GDX PLYWD. OR 055 Q3 w/ Sd'S a 5",12" O.G. w/ 4x STUDS a ADJ. PANEL 5PLIGE5 Q5/8" COX PLYWD. OR 055 2 w/ Sd'5 a 2",12" O.G. w/ 4x STUDS a ADJ. PANEL SPLICES I. NAILS SHALL BE COMMON NAILS (2v2"x.131"), TYP., U.O.N. 2. ALL PLYWOOD PANELS SHALL HAVE ALL EDGES BLOCKED. RIGHT ELEI/ATION I/a, 10080 BARN DOOR 6x10 F _;_1 / LL I �101 GpQ b I I Lef-----I .xx \ X `Z N `9 O I I SHOP 10' CLO. GONG. 1 1 11 1 I IuJll d. 1 l I PI I'llid 11 / I GFI L_/ ----I Kbib.4' 6.4' I I NOTE: GFI GARAGE WALLS AND GLC. I FIN. TO BE MIN." GYP. BD. Ira x x)11O / K616.4' 6FI OTE: 6ARACE RECEPTACLES 43 3 \ 1 TO BE +18" MIN. A.F.F. x x 068 \ n )'2 LITE I 22 q3% `6 6x10 / `I > 10080 BARN DOOR 14.3' _ =LOOK PLAN 1/4" = I'-( PERMIT# 616-200) BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR CODE COMPLIANCE DATE -(e':( AREAS: GARAGE AREA: -Fr7l-5Q. FT. PORCH AREA: 300 SQ. FT. ReNslon: S ENERAL NOTE5 By: 6-I.I „,,, . Y ( CONCRETE I. CONCRETE TO BE 5 SACK MIX, 2500 P51 a 28 DAYS 2. REINFORCING STEEL TO BE INTERMEDIATE GRADE DEFORMED BARS -TYPE N OR 40. ROUSH CARPENTRY I. INSTALL BLOGKINS AS REQUIRED TO SUPPORT FINISH • 'W � o o HARDWARE AND FIRE STOPPING TO GUT OFF CONGEALED y DRAFT OPENINSS A5 REQUIRED BY CODES. d' O 2. STRUCTURAL FRAMING SHALL BE DOU6LA5 FIR TO THE CID 0. in hal r � U GRADES INDICATED OR BETTER (WWPA GRADING RULES) - on UNLE55 NOTED OTHERWI5E. � CONGEALED 4x BEAMS B POSTS ......................... NO. 2 �W EXPOSED 4x BEAMS 3 POSTS...............................NO. I (ox BM5 E POSTS.........................................................NO. I 2x JOISTS AND RAFTERS........................................NO. 2 00 _ r STUD, SILLS, PLATES...................................................NO. 2 M I� SILLS ON CONCRETE...................................................PTHF MISC. FRAMING NOT NOTED....................................NO. 2 3. PLYWOOD SHALL BE OF THE DEVONATED GRADE AND SHALL MEET THE REQUIREMENTS OF THE U.S. PRODUCT STANDARDS P5 1-55. MITRE PORCH-/ 4. NAILS AT PLYWOOD PANELS SHALL HAVE s/e" EDGE BEAMS o/ bx6 DISTANCE AND SHALL NOT PENETRATE FACE -PLY. P05T d ATTACH 5. NO PIECE OF PLYWOOD ROOF, FLOOR OR WALL TO POST w/ SHEATHING SHALL BE LESS THAN 12" IN LEAST DIRECTION. "SIMPSON" 'L' b. FRAMING HARDWARE SHALL BE SIMP50N STRONG -TIE OR STRAPS, TYP. H APPROVED EQUAL, WITH CONNECTORS AS SPECIFIED CT '1. PROVIDE SOLID BEARING CONTINUOUS FROM ALL BEAMS COYD, TO FOUNDATION. 8. PROVIDE FIRE BLOGKINS IN CONGEALED SPACES VERTICALLY AND HORIZONTALLY IN ACCORDANCE w/ 2013 G.R.G. SECTION 8302.11. 9. FASTENERS FOR PRESERVATIVE TREATED AND FIRE TREATED WOOD SHALL BE OF HOT DIPPED ZING COATED AAA. V X00 GALVANIZED STEEL, SILICON BRONZE OR COPPER. THE COATING WEIGHTS FOR ZING COATED FASTENERS SHALL BE IN ACCORDANCE w/ A5TMA 153. 2013 G.R.G. SECTION 8317.3. 10. EACH 51ME OF TOP PL. LAP SPLICE SHALL HAVE (5) Ibd PETAGHED (5�" x .135" (P) MIN., TYP. 11. TYPICAL FASTENERS SHALL BE INSTALLED IN CONFORMANCE w/ GBG TABLE 2304.9.1. Dmw' GAS 12. STRUCTURAL COMPOSITE LUMBER SHALL BE VERSA -LAM 'ob I6-2216 Fb5100 OR VER5A-RIM AS MFR. BY BOISE CASCADE. 13. BEARING WALL HDR5. SHALL BE 4xIO #2 OR 6x8 D.F. #1 MIN., TYP., U.O.N. RIGHT ELEI/ATION I/a, 10080 BARN DOOR 6x10 F _;_1 / LL I �101 GpQ b I I Lef-----I .xx \ X `Z N `9 O I I SHOP 10' CLO. GONG. 1 1 11 1 I IuJll d. 1 l I PI I'llid 11 / I GFI L_/ ----I Kbib.4' 6.4' I I NOTE: GFI GARAGE WALLS AND GLC. I FIN. TO BE MIN." GYP. BD. Ira x x)11O / K616.4' 6FI OTE: 6ARACE RECEPTACLES 43 3 \ 1 TO BE +18" MIN. A.F.F. x x 068 \ n )'2 LITE I 22 q3% `6 6x10 / `I > 10080 BARN DOOR 14.3' _ =LOOK PLAN 1/4" = I'-( PERMIT# 616-200) BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR CODE COMPLIANCE DATE -(e':( AREAS: GARAGE AREA: -Fr7l-5Q. FT. PORCH AREA: 300 SQ. FT. ReNslon: Date: By: „,,, . Y ( • 'W � o o y d' h�1 V CID 0. hal r � U � `/ on � �W 00 _ r M I� I� �H0C) PA�w H CT COYD, O AAA. V X00 * No. 2128 7/1 ILINSKI PETAGHED SHOP Date AUGUST 2016 Stele Dmw' GAS 'ob I6-2216 sneer IN Sheets N O „,,, . Y ( m SOLID P.T. SILL W/Y2 " DIA. x 12" ob. ® V O.G. AND 12" MAX. FROM ENDS W/ 3"x5"x.2241" PLATE WASHERS, TYP. GONG. SLAB, 5EE FOUNDATION PLAN #4 ® 4'-0" FINISH SRAD'E—IIII I dl ll� hIIhIIhIII;�IIIIJII�I b� NAT.6RADEIN. a 111111111.,,,111111, a #4 TOP 8 BOTTOM PERIMETER FOOTINO F-4 I" = ROOF PLY: 5HEARPLY; SEE PLAN 2 R- I ROOF TRL Ibd SINKERS ®8" O.C.— A55 ® 4'-0" O.G., TYP. U.O.N. I" MIN. AIR SPACE TO INSULATION VENTS E,4\/E DETAIL I" = 3/g" GDX. PLYWD. OR 05B w/ 8d'5 ® 611,12" O.G. 2x6 SOLID ELKS. ibd SINKERS E.N. 5HEARPLY; SEE FLOOR PLAN ,435'5 2'-0" O.G. I6_ E.N. 5HEAR TRAN5FER R-108 III = II -011 ROOF NOTES: I. ROOF FRAMING SHALL BE: PRE -MFR TRUSSES ® 24" O.G. TYP. U.O.N. 2. ROOF PITCH SHALL BE: 6:12, TYP. 3. ROOF O.H. SHALL BE: 1'-b" ® 6:12 PITCH 4. ROOF COVERING SHALL BE: COMP. SHINGLES o/ I5# FELT 0/,IT GDX OR 05B. H/ 8d'5 ® 61,12" O.G. 5. REQUIRED ATTIC VENTILATION: 1800 / 300 = 6.0 50. FT. OF NET FREE AREA VENTILATION REQUIRED. -LOIN VENTING: PROVIDE (10) 5�"x228" SAVE VENT5 ® .33 50. FT. EACH. TOTAL LOW VENTING PROVIDED: 3.3 50. FT. OF NET FREE AREA • HISH VENTING (LOCATED MAX. V VERTICAL BELOW RIDGE): PROVIDE MIN. 13' CONT. RIDSE VENT ® 0.125 50. FT. PER FT. $ PROVIDE (4) LOW PROFILE DORMER VENTS ® .45 SQ. FT. TOTAL HISH VENTING PROVIDED: 3.43 SQ. FT. OF NET FREE AREA. COMP. SHINSLE5 o/ 15# FELT o/ Y," COX OR 058. H/ 8d'5 ®b", I2" O.G. ROOF 5/e' SYP. BD. OR Yza GD. BD. ® GLC. (OPTIONAL) I GYP. BD. ® , (OPTIC 0 2x6 STUDS ® 1611 O.C.- R-141 IN5UL. (OPTIONAL) SEE FDN. PLAN SECTION A-1 1/4":=:r _] �.r Is Dale: INo l N - i CONT. RIDGE VENT I 6:12 6:12 r CN N 0 F -ROOF PLAN 1/8" = I'-0" SS�� S<,�,,`d of Ib" 50. x 12" DP. Ubb BASE, TlrF. I I I I I I / I I L/ I I 4" GONG. SLAB w/ #3 I BAR ® 2'-O" O.G. BOTH pJ I WAYS o/ 4" BASTE I I " GONG. SLAB I I I I o] I I I I I I I I I I I 2 FOUNDATION PLAN 1/8.. FOUNDATION NOTES: I. GROUND IMMEDIATELY ADJACENT TO THE FOUNDATION SHALL BE SLOPED AWAY FROM THE BUILDING AT A SLOPE OF NOT LESS THAN 6" WITHIN THE FIRST 10 FT. (5% SLOPE). PER 2013 GRG SECTION 8401.3 2. ALL FOOTINGS SHALL BE FOUNDED ON UNDISTURBED NATIVE SOIL. PERMIT REVIEwtu ruts O C DE COMPLIANCEn DATE Revisal: Dale: By: r CN rI� 0 M � In .c in fm tj F�1 U @) o tu v L) � czW M O f—I E� ARC U � ORY 'A �0 * No. 21283 v� R . 7/17 BILINSKI VETACHED SHOP Date,A000ST 2016 Scale D'e" GAS '°" I6-2216 Sheet 2 Of Sheets 2013 CALGreen Residential Mandatory Measures Planning and Design 4.106.2 - Storm Water Drainage and Retention - Projects which disturb less than one acre of soil and are not part of a larger common plan of development shall manage storm water drainage during construction. 4.106.3 - Grading and Paving - Construction plans shall indicate how the site grading and drainage system will manage all surface water flows to keep water from entering building. Exception: Additions or alterations not altering the drainage path. 4.106.4.1- Electric Vehicle (EV) charging - For new constructed dwelling units, install a listed raceway to accommodate a dedicated 208/24D -volt branch circuit. The raceway shall not be less than trade size 1(nominal 1 -inch inside diameter). The raceway shall originate at the main service or subpanel and shall terminate into a listed cabinet, box or other enclosure in close proximity to the proposed location of an EV charger. Raceways are required to be continuous at enclosed, inaccessible or concealed areas and spaces. The service panel and/or subpanel shall provide capacity to install a 40 -ampere minimum dedicated branch circuit and space(s) reserved to permit installation of a branch circuit overcurrent protective device. The service panel or subpanel circuit directory shall identify the overcurrent protective device spaces(s) reserved for future EV charging as "EV CAPABLE". The raceway termination location shall be permanently and visibly marked as "EV CAPABLE". Energy Efficiency 4.201.1-5.201.1- Low-rise residential (Section 4.201.1) and high-rise residential/hotel/motel (Section 5.201.1) building shall meet or exceed the minimum standards design required by the California Energy Standards. Standards for residential buildings do not require compliance with levels of minimum energy efficiency beyond those required by the 2013 California Energy Code. Water Efficiency and Conservation Indoor Use - 4.303.1- Water Conserving Plumbing Fixtures and Fittings. - Plumbing fixtures and fittings shall comply with the following: 4.303.1.1 - Water closets flush volume shall not exceed 1.28 gals per flush. 4.303.1.2 - Urinals flush volume shall not exceed 0.5 gals per flush. 4.303.1.3.1- Single showerheads shall have a maximum flow rate of not more than 2.0 gpm. 4.303.1.3.2 - Multiple showerheads shall have a combined flow rate of all showerheads and/or shower outlets controlled by a single valve shall not exceed 2.0 gpm or only one shower outlet to be in operation at a time. 4.303.1.4.1- Residential lavatory faucets maximum flow rate shall not exceed 1.5 gpm. The minimum flow rate shall not be less than 0.8 gpm. 4.303.1.4.2 - Lavatory faucets in common and public areas of residential buildings shall not exceed 0.5 gpm. 4.303.1.4.3 - Metering faucets shall not deliver more than 0.25 gals per cycle. 4.303.1.4.4- Kitchen faucets maximum flow rate shall not exceed 1.8 gpm. Kitchen faucets may temporarily increase the flow above the maximum rate, but not to exceed 2.2 gpm. Note: When complying faucets are unavailable, aerators or other means may be used to achieve reduction. 4.303.2 - Plumbing fixtures and fittings shall be installed in accordance with the Plumbing Code. Outdoor Use - 4.304.1- Irrigation Controllers - Automatic irrigation system controllers for landscaping by the builder and installed at the time of final inspection shall comply with the following: 1. Controllers shall be weather- or soil moisture -based controllers that automatically adjust irrigation in response to changes in plant watering needs as weather or soil conditions change. 2. Weather -based controllers without integral rain sensors or communication systems that account for rainfall shall have a separate wired or wireless rain sensor which connects or communicates with the controller(s). Material Conservation and Resource Efficiency 4.406.1- Rodent Proofing -Annular spaces around pipes, electric cables, or other openings in sole/bottom plates at exterior walls shall be closed with cement mortar, concrete masonry or a similar method acceptable to the enforcing agency to prevent passage of rodents. 4.408.1- Construction Waste Reduction of at least 50%- A minimum of 50% of the construction waste generated at site is diverted to recycle or salvage. 4.408.2 Construction Waste Management Plan - Submit a construction waste management plan meeting items 1-5 in Section 4.408.2. Plans shall be undated as necessary and shall be available for examination during construction. 4.408.3 - Waste Management Company - Utilize a waste management company, approved by the enforcing agency, which can provide verifiable documentation that diverted construction and demolition waste materials meet the requirements in Section 4.408.1. 4.408.4 - Waste Stream Reduction Alternative - Generate a total combined weight of construction and demolition waste disposed in landfills that is equal to or less than 4 lbs per sq. ft. of the building area. 4.408.4.1- Waste Stream Reduction Alternative (High -Rise Residential) - Generate a total combined weight of construction and demolition waste disposed in landfills that is equal to or less than 2 lbs per sq. ft. of the building area. 4.410.1- Operation & Maintenance Manual - An operation and maintenance manual shall be provided to the building owner or occupant. Environmental Quality 4.503.1 General - Any installed gas fireplace shall be a direct -vent sealed -combustion type. Any installed woodstove or pellet stove shall comply with US EPA Phase II emission limits where applicable. Woodstoves, pellet stoves, and fireplaces shall also comply with applicable local ordinances. 4.504.1 Coverings of Duct Openings and Protection of Mechanical Equipment during Construction - Duct openings and other related air distribution component openings shall be covered during construction. 4.504.2.1- Adhesives, Sealants and Caulks -Shall be compliant with VOC and other toxic compounds limits. 4.504.2.2 - Paints and Coatings -Shall be compliant with VOC limits. 4.504.2.3 -Aerosol Paints and Coatings -Shall be compliant with product weighted MIR limits for ROC and other toxic compounds. 4.504.3 - Carpet Systems - Shall be compliant with VOC limits. 4.504.4 - Resilient Flooring Systems - 80% of floor areas receiving resilient flooring shall comply with the VOC - emission limits defined in the Collaborative for High Performance Schools (CHPS) Low -emitting Materials List or to be certified under the Resilient Floor Covering Institute (RFCI) FloorScore Program. 4.504.5 - Composite Wood Products - Particleboard, medium density fiberboard (MDF) and hardwood plywood used in interior finish systems shall comply with low formaldehyde emission standards. 4.505.2 - Concrete Slab Foundations -A vapor retarder and capillary break is installed at slab on grade foundations. 4.505.3 - Moisture Content of Building Materials - Wall and floor framing materials shall be checked before enclosure. 4.506.1- Bathroom Exhaust Fans - Exhaust fans which terminate outside the building are provided in every bathroom. 4.507.2 - Heating and Air Conditioning System Design - Duct systems are sized , designed, and equipment selected using the following methods: 1. Establish heat loss and heat gain values according to ACOA Manual J or equivalent. 2. Size duct systems according to ACOA 29-D (Manual D) or equivalent. 3. Select heating and cooling equipment according to ACCA 36-S (Manual S) or equivalent. Installed & Special Inspection Qualifications 702.1- HVAC system installers are trained and certified in the proper installation of HVAC systems and equipment. 702.2 Special inspectors must be qualified and able to demonstrate competence to the enforcing agency in the discipline in which they are inspecting. 703.1- Documentation - Verification of compliance with the code may include construction documents, plans, specifications, builder or installer certification, Inspection reports, or other methods of acceptable to the enforcing agency which show substantial conformance. 1 l - - -- -.- ----- - - -� If T I ] 111-7 TABLE 4.504.1 AID" ESIVE VOC LIM[TI,2 Lsgt Watt and Lost Ex2lnlstCompoundi h Gramtl por09? ARCHITECTUR.4LApp LicATious CUPPENTVOCUMIT _ [TIckvircuretadhesives 53 Ca vzt padadboshvs 5) Outdonr camel adhesh-ex 150 '►Void nr_.cri:na adhr shx? 100 RubN7 floQ r a( ksh rs 450 Suhfioor altksim 4" Ceramic 31.E adhesivcs 65 'l'C7 and as lialttile adh si vs 5) Drywall and pancIwdhcsii-ova 5 -In Caen tsaas a dhkNi m WOO 11ittltt.0 ,i-onsaurti0inadhmc hvs 700 StructrtraJ Elazin 'adhesiws too Si Qic: IA rm.ffnemtD.ta7lrSM,5 O d3thcrndhesiw-snnts �c'fieallyli>tcd 3P SPECIALTY APPLICATIONS - PVtC vrldine IS In CPV17 weldillZ 490 ABS wldjrn* 32 PI esticcement w,ldine 25n Adlhesi vv, PrirnerFor plastis 550 Cantnsl adhesive Rre resistive confln2u .S'i P wL-d u M030WDta01 dhosia%+ 250 Struchtml wnad mcmher adhesi.k 140 7v w and tri on adliesive 250 SUBSTRATE SPEfilFIC APPLICATiONS Nlet<1l to metal 3) PI astir foams _5n Pnrnusmated at(exee tw+ord) 50 'r,5'nod 4.? F f cmgm s Eta 1. If an adhesive is used it., lid di.similar aursrates together, the adhesive with the highest VOC content shall Ir allcmcd. 2. T",-radd itionatinfntmationirepArdincmethods tom a-suretheVr3�'crnnknt specified in this table, see South Coast Air Quality Manageanent Umtrict Rule 1169. TABLE 4504.2 _ SEALANT VOC LIFArF Lis! Watera nd Loss Exempt Compounds In Graters per Litor SEALANTS CUPP ENT TOC LIMIT Archlu cnttal 1 141adn deck 700 Tlanmvmbrzmax t IX1 Medium demitr fib i -be d Nontlat-hi Ea I.a.wzk-Bn s Sin fc* lvr 1'mcml,ra , 450 Other 420 SEALANT PAVAI:AS ArOitvchfredl Nonpxnus Porous 2`a3 775 Midiflod bituminous 5 -In ?utati:ne d -N -k WOO Other 7�d) TABLE 4SOd.3 ?VOCCONIENT LIFAITS FOR AECHTECTURAL TIMIIS" Grilingof VOC porLftIaTOlCoating, Lots Water and Loss Exompt COinpou Hti1 COAT NO CATEGOPY EFFECTIVE illi -2151116 EFFt:Cn%r= 9/f.f2012 1~t.moontifi ;K M RM Ntattflatcwtin _5 IX1 Medium demitr fib i -be d Nontlat-hi Ea I.a.wzk-Bn s t 0.1 .3 SPECIALTit COAnNnS Aluminum roof m mines Bnnetntntc. clalttcoatt Bilintniftms roafcoatings 51 Bintminnns roof prilnerl 35J Bomd tare*m 359 O fe-na-eta onvirm onni mftb 3P • W (Imcretehnnsrnry waters Ion Drinway "ers 9 Dry bp coatin i 1Sr Faua finittfifri' rcan$n s i-++7 Rre resistive confln2u 119of coatior a Form-feleavecsm amis 250 Graphic art% omfines ftircPaints) Mfg I--i--I lfr ;h tem ,rotate coatingg 420 lndLcW mal ntanzwcec4japs 150 Law solidsoni' i IM Mo e3ltecementcoatinxa 450 AR �Sv0CA��F Maack terme matin75 10) McLallic r4kmeritod coati n :s 500 -kfulticotcx coofinp a 250 Pretmahren I wash Primers 420 MANDATORY ihj.lnxas, TRa1P*tx. ant tindermatets I M Date l y' Reactive pervir-0jing sea'Irr€' ' 330 Reo,Med.coati M RootZmfin s -55 Rust SO 250 Shelters iCkar Opaque 7?? 35;0 Rrcdrilly rjrne". wa emam DrAelerelkra 35.0 100 w% 2_90 Rom mt .Ndanta fit? swimming pool coat n x 110 Trsflic caadcinA waffinp too Tuts and tide refinish cwdnel 42210 wailer roofut rnernbranes 50 %:ndoDrdinp 275.. ';;'gid 3511 Zinc-ftb primers 344 1. Grams of VOC per literof cnotirtg including vmw and including exempt compounds. 2. 7 be spFclfred limits remain in effect unless revi+rdlimi is am -1 O ed in sub se- quem columns in ttv tthle. 3. '46tues in th s table are ckriied from those specifetl by'tte California Air Rmmrces Board, Architectural Coatings Su gesta:l Control 24iteosure; Rbmary 1;'2008. More infomatrn Is arnlllable from cite Air itescurces' Elnwct TABLE 4.504.5 FORMALDEHYDE UM1TSf Maaxfmumn Formaldehyde Eminsiorrs in Pgrts "r ldljllfort PRODUCT CURPENT LINT flardwond rxo_dvzneercorrz 0.l:35 Flarchyood plywood corn _dgila cam* RM Particl&onrd M09 Medium demitr fib i -be d 0,11 Thin medium density fiberfwoarti' 0.1 .3 1,, tltlue5 in this talalo my &d%vd fm0 m Ao90 sp acirti2d Irl the Call fomla Air Re."raea Board- Air Tatics CtntroI Tvleavii te for Campo%Ite Hood n fisted in arcefdance with ASTM E 1333. For addidolird infrnmati0n *rte Caldr�2mfaiCedevfRegff&,r qF,,741e17,15ecUQns93120through913129.12. ?, Thin nrdiumd ittyritkit. ttlinvamaxi mum thlckTum.sof 5&irdtSrwnl. PERMIT# ✓�p BUTTE COUNTY DEVELOPMENT SERVICES QREVIEWED FOR CO(���,,EttCOMPLIANCE DATE THE PROJECT MANAOER OR OENERAL CONTRACTOR N I LL BE THE RESPONS I BLE PERSON TO COLLECT AND PROV I ISE VERIFICATION OF CALOREEN GOMPL I ANGE TO THE BU I LD I NO INSPECTOR PRIOR TO BU I LD I NO FINAL. 1' 11_7 T _- Revisloo: Date: By: Fall Ir - 00 � rr�11+ Fah'1 � O • W N In ENO O yu U d U"� a >= b W a 00 M I--i--I AR �Sv0CA��F * No. 21 83 RE /17 ALOREEN MANDATORY MEA5URE5 Date l y' Ogre ; i Sheet QOfShoes '.1 T4 M r• M fV epi O N a � SII' i � �i ��I� il� I I �I f .yir V � SII' i � �i ��I� il� I I �I f