Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B16-2313 000-000-000
APPLICABLE CODES 2011 NATIONAL ELECTRICAL UODE (NEC) 2012 INTERNATIONAL BUILDING CODE (IBC) 2013 CALIFORNIA BUILDING CODE (CBC) 2013 CALIFORNIA ELECTRICAL CODE (CEC) 2013 CALIFORNIA GREEN BUILDING STANDARDS CODE (CGBSC) 2013 CALIFORNIA FIRE CODE (CFC) - INSTALLATION CONSISTS OF (40) HANWHA Q.PLUS L -G4.2 335, (2) SOLECTRIA RENEWABLES PVI-520OTL (240) WITH MONITORING SYSTEM AND RELATED MOUNTING AND SAFETY EQUIPMENT. ALL COMPONENTS ARE UL LISTED AND CEC CERTIFIED, WHERE WARRANTED ALL EQUIPMENT WILL BE INSTALLED AS REQUIRED BY APPLICABLE CODES AND LOCAL UTILITY COMPANY REQUIREMENTS. SYSTEM SIZE: 13.4 KW PV MODULE: (40) HANWHA Q.PLUS L -G4.2 335 RACKING: UNIRAC INVERTERS: (2) SOLECTRIA RENEWABLES PVI-520OTL (240) VICINITY MAP -rtY n J e Ozk2tle Hegtitc ElementaryStlwW n SITE LOCATION T'.. U-1, a -.«.,d ° L Ororilk L Cemttery Disitlq 1.Ipmarlel Pan eemeuerY 7-Elecea - 2 EY101W,se RWhtrd Monte Vida Ave nt�inrn `diSt.i Av- M. SCALE:NTS is a ABREVIATIONS (E) EXISTING (N) NEW GND GROUND PNL PANEL BOARD OR PANEL J -BOX JUNCTION BOX MSP MAIN SWITCH PANEL PVC POLYVINYL CHLORIDE EMT ELECTRIC METAL TUBING FMC FLEXIBLE METAL CONDUIT NEMA NATIONAL ELECTRIC MANUFACTURES ASSOCIATION - INSTALLATION CONSISTS OF (40) HANWHA Q.PLUS L -G4.2 335, (2) SOLECTRIA RENEWABLES PVI-520OTL (240) WITH MONITORING SYSTEM AND RELATED MOUNTING AND SAFETY EQUIPMENT. ALL COMPONENTS ARE UL LISTED AND CEC CERTIFIED, WHERE WARRANTED ALL EQUIPMENT WILL BE INSTALLED AS REQUIRED BY APPLICABLE CODES AND LOCAL UTILITY COMPANY REQUIREMENTS. SYSTEM SIZE: 13.4 KW PV MODULE: (40) HANWHA Q.PLUS L -G4.2 335 RACKING: UNIRAC INVERTERS: (2) SOLECTRIA RENEWABLES PVI-520OTL (240) VICINITY MAP -rtY n J e Ozk2tle Hegtitc ElementaryStlwW n SITE LOCATION T'.. U-1, a -.«.,d ° L Ororilk L Cemttery Disitlq 1.Ipmarlel Pan eemeuerY 7-Elecea - 2 EY101W,se RWhtrd Monte Vida Ave nt�inrn `diSt.i Av- M. SCALE:NTS is a GENERAL NOTES 1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH CALIFORNIA OSHA REQUIREMENTS. 2. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE. 3. THIS SYSTEM IS A UTILITY GRID INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. 4. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION 110.26 NEC. 5. HEIGHT OF INTEGRATED AC/DC DISCONNECT SHALL NOT EXCEED 6'-7" PER NEC 240.24. 6. SITE CONDITIONS SHALL PREVAIL. 7. IF NO SCALE IS GIVEN, DRAWINGS ARE NOT TO SCALE. ALL DIMENSIONS SHALL BE VERIFIED BY SUBCONTRACTOR AND SUBCONTRACTORS IN THE FIELD UPON COMMENCEMENT OF CONSTRUCTION. GROUNDING NOTES 1. SINGLE -CONDUCTOR CABLE USED AS A GROUNDED CONDUCTOR IN PHOTOVOLTAIC POWER SYSTEMS SHALL BE IDENTIFIED AT THE TIME OF INSTALLATION BY A DISTINCTIVE WHITE MARKING AT ALL TERMINATIONS. 2. THE DC GEC SHALL BE CONTINUOUS FROM THE INVERTER BUSBAR GROUND TO THE MAIN ELECTRICAL SERVICE GROUNDING SYSTEM. 3. THE DC GEC SHALL SHALL BE ATTACHED TO THE GROUNDING SYSTEM BY AN IRREVERSIBLE MEANS PER NEC 250.64 AND 690.47. 4. PV INVERTER CONTAINS A GROUND FAULT DETECTOR INTERRUPTER. 5. THE DC GROUND SYSTEM SHALL BE CONNECTED ONLY THROUGH THE INVERTER. 6. ALL EXPOSED METAL PARTS SHALL BE CONNECTED AND/OR BONDED TO THE GEC SYSTEM BY UL LISTED COMPONENTS ONLY. 7. MODULE FRAMES SHALL BE GROUNDED AT THE MANUFACTURER PROSCRIBED LOCATION BY REQUIRED UL LISTED BONDING DEVICES. 8. METALLIC CONDUIT SHALL BE BONDED AT BOTH ENDS TO THE GEC PER NEC 250.64(E). 9. GROUNDING ELECTRODE CONDUCTOR TO BE BONDED TO EXISTING UFER GROUND PER NEC 250.30(A). 10. DC GROUNDING ELECTRODE CONDUCTOR SIZED PER NEC 250.166(D). 11. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH NEC 690.47,250.50-250.60 AND 250.166 SHALL BE PROVIDED. PER NEC, GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE OR INADEQUATE OR IS ONLY METALLIC WATER PIPING, A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 5/8 INCH BY 8 FOOT GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE GROUND SIGNAGE NOTES 1. SIGNAGE SHALL BE PROVIDED PER NEC 690.51-56. 2. ALTERNATE POWER SOURCE PLACARDS SHALL BE PLASTIC AND IN A CONTRASTING COLOR TO THE PLAQUE. 3. THE PLAQUE SHALL BE ATTACHED USING AN APPROVED METHOD. 4. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. INTERCONNECTION NOTES 1. SUPPLY SIDE INTERCONNECTIONS SHALL COMPLY WITH NEC 705.12 AND NEC 230. 2. SUPPLY SIDE INTERCONNECTIONS SHALL BE MADE IN ACCORDANCE WITH THE EQUIPMENT MANUFACTURER'S INSTRUCTIONS AND SHALL NOT INVALIDATE THE UL LISTING OF THE EQUIPMENT. 3. RMC TYPE CONDUIT SHALL BE USED TO ENCLOSE CONDUCTORS BETWEEN A SUPPLY SIDE INTERCONNECTION AND THE FIRST OCP IN THE INVERTER OUTPUT CIRCUIT. 4. LINE SIDE TAPS SHALL BE INSTALLED PER MANUFACTURERS INSTRUCTIONS USING A UL LISTED DEVICE AND SHALL NOT INVALIDATE THE UL LISTING OF THE EQUIPMENT. PERMIToil�/1� BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR �®P.. C mew M PLI w = t I3Y SYMBOLS KEY EQUIPMENT MANUFACTURER QM METER PHOTOVOLTAIC MODULES: PV -02 ARRAY & SITE LAYOUT HANWHA ® INVERTER www.hanwha.com PV -04 GROUND PV -05 RACKING: SWITCH UNIRAC www.unirac.com Q/a FUSE 0 o BREAKER INVERTER: OCT 24 2016 SOLECTRIA RENEWABLES DEVELOPMENT www.solectda.com GENERAL NOTES 1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH CALIFORNIA OSHA REQUIREMENTS. 2. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE. 3. THIS SYSTEM IS A UTILITY GRID INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. 4. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION 110.26 NEC. 5. HEIGHT OF INTEGRATED AC/DC DISCONNECT SHALL NOT EXCEED 6'-7" PER NEC 240.24. 6. SITE CONDITIONS SHALL PREVAIL. 7. IF NO SCALE IS GIVEN, DRAWINGS ARE NOT TO SCALE. ALL DIMENSIONS SHALL BE VERIFIED BY SUBCONTRACTOR AND SUBCONTRACTORS IN THE FIELD UPON COMMENCEMENT OF CONSTRUCTION. GROUNDING NOTES 1. SINGLE -CONDUCTOR CABLE USED AS A GROUNDED CONDUCTOR IN PHOTOVOLTAIC POWER SYSTEMS SHALL BE IDENTIFIED AT THE TIME OF INSTALLATION BY A DISTINCTIVE WHITE MARKING AT ALL TERMINATIONS. 2. THE DC GEC SHALL BE CONTINUOUS FROM THE INVERTER BUSBAR GROUND TO THE MAIN ELECTRICAL SERVICE GROUNDING SYSTEM. 3. THE DC GEC SHALL SHALL BE ATTACHED TO THE GROUNDING SYSTEM BY AN IRREVERSIBLE MEANS PER NEC 250.64 AND 690.47. 4. PV INVERTER CONTAINS A GROUND FAULT DETECTOR INTERRUPTER. 5. THE DC GROUND SYSTEM SHALL BE CONNECTED ONLY THROUGH THE INVERTER. 6. ALL EXPOSED METAL PARTS SHALL BE CONNECTED AND/OR BONDED TO THE GEC SYSTEM BY UL LISTED COMPONENTS ONLY. 7. MODULE FRAMES SHALL BE GROUNDED AT THE MANUFACTURER PROSCRIBED LOCATION BY REQUIRED UL LISTED BONDING DEVICES. 8. METALLIC CONDUIT SHALL BE BONDED AT BOTH ENDS TO THE GEC PER NEC 250.64(E). 9. GROUNDING ELECTRODE CONDUCTOR TO BE BONDED TO EXISTING UFER GROUND PER NEC 250.30(A). 10. DC GROUNDING ELECTRODE CONDUCTOR SIZED PER NEC 250.166(D). 11. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH NEC 690.47,250.50-250.60 AND 250.166 SHALL BE PROVIDED. PER NEC, GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE OR INADEQUATE OR IS ONLY METALLIC WATER PIPING, A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 5/8 INCH BY 8 FOOT GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE GROUND SIGNAGE NOTES 1. SIGNAGE SHALL BE PROVIDED PER NEC 690.51-56. 2. ALTERNATE POWER SOURCE PLACARDS SHALL BE PLASTIC AND IN A CONTRASTING COLOR TO THE PLAQUE. 3. THE PLAQUE SHALL BE ATTACHED USING AN APPROVED METHOD. 4. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. INTERCONNECTION NOTES 1. SUPPLY SIDE INTERCONNECTIONS SHALL COMPLY WITH NEC 705.12 AND NEC 230. 2. SUPPLY SIDE INTERCONNECTIONS SHALL BE MADE IN ACCORDANCE WITH THE EQUIPMENT MANUFACTURER'S INSTRUCTIONS AND SHALL NOT INVALIDATE THE UL LISTING OF THE EQUIPMENT. 3. RMC TYPE CONDUIT SHALL BE USED TO ENCLOSE CONDUCTORS BETWEEN A SUPPLY SIDE INTERCONNECTION AND THE FIRST OCP IN THE INVERTER OUTPUT CIRCUIT. 4. LINE SIDE TAPS SHALL BE INSTALLED PER MANUFACTURERS INSTRUCTIONS USING A UL LISTED DEVICE AND SHALL NOT INVALIDATE THE UL LISTING OF THE EQUIPMENT. PERMIToil�/1� BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR �®P.. C mew M PLI w = t I3Y ma i no av l k -as 15 Pepsi Way Durham, CA 95938 Ph:530.345.9910 Fax:530.345.3074 PROJECT INFORMATION OWNER NAME NEW HOPE MISSIONARY BAPTIST CHURCH ADDRESS 5640 LINCOLN BOULEVARD CITY OROVILLE, CA 95966 AUTHORITY HAVING JURISDICTION BUTTE COUNTY ASSESSORS PARCEL NUMBER 78-190-020 SYSTEM INFORMATION SIZE 13.4 KW RACMNG TYPE ROOF MOUNT INTERCONNECTION TYPE 200A - 240V GRID TIED TOTAL MODULES (40) HANWHA Q.PLUS L-34.2 335 INVERTER 2) SOLECTRIA RENEWABLES PVI-5200TL (240) DESIGNER'S SIGNATURE C,�"`� VL' -7 SHEETINDEX PV -01 TITLE SHEET APPROVED BY: PV -02 ARRAY & SITE LAYOUT PV -03 ELECTRICAL DIAGRAM PV -04 ELECTRICAL CALCULATIONS PV -05 STRING MAP BUTTE ('OUNTY OCT 24 2016 DEVELOPMENT SERVI(`ES ma i no av l k -as 15 Pepsi Way Durham, CA 95938 Ph:530.345.9910 Fax:530.345.3074 PROJECT INFORMATION OWNER NAME NEW HOPE MISSIONARY BAPTIST CHURCH ADDRESS 5640 LINCOLN BOULEVARD CITY OROVILLE, CA 95966 AUTHORITY HAVING JURISDICTION BUTTE COUNTY ASSESSORS PARCEL NUMBER 78-190-020 SYSTEM INFORMATION SIZE 13.4 KW RACMNG TYPE ROOF MOUNT INTERCONNECTION TYPE 200A - 240V GRID TIED TOTAL MODULES (40) HANWHA Q.PLUS L-34.2 335 INVERTER 2) SOLECTRIA RENEWABLES PVI-5200TL (240) DESIGNER'S SIGNATURE C,�"`� VL' -7 PROJECT NO. 16-055 DRAWN BY: EC DATE 10/13/2016 APPROVED BY: REVISION SCHEDULE NO. DATE DESCRIPTION 1 2 3 4 l1 inch I Scale to Confirm 11"x17" Plot @2016, SUN k$ SHEET TRLE' TITLE SHEET 1 PV -01 This document along with the ideas and designs presented herein are the property of SUNwores and is not to be used in whole or in Dart without the express written consent of SUNw-s F�tE COFY PROPERTYOFSLININ INC. w°(DpD� 15 Pepsi Way Durham, CA 95938 Ph:530.345.9910 Fax:530.345.3074 PROJECT INFORMATION OWNER NAME NEW HOPE MISSIONARY BAPTIST CHURCH ADDRESS 5640 LINCOLN BOULEVARD CITY OROVILLE, CA 95966 AUTHORITY HAVING JURISDICTION BUTTE COUNTY ASSESSORS PARCEL NUMBER 78-190-020 SYSTEM INFORMATION SIZE 13.4 INV RACKING TYPE ROOF MOUNT INTERCONNECTION TYPE 200A - 240V GRID TIED TOTAL MODULES (40) HANWHA Q. PLUS L -G4.2 335 INVERTER 2) SOLECTRIA RENEWABLES PVI-520OTL (240) ❑ � ,. `"++vDESIGNER'S SIGNATURE t ROOF MOUNT SOLAR ARRAY — — — - '(40) PV MODULES /v �r PROJECT NO. DRAWN BY: ` POINT OF INTERCONNECTION 16-055 EC - _ -- - (E) METER/MAIN SERVICE PANEL l ��""�� �- .-� DATE APPROVED BY (N) AC DISCONNECT SOLAR EQUIPMENT 10/13/2016 REVISION SCHEDULE NO. DATE DESCRIPTION 1 2 3 4 � 1 inch I Scale tD Confirm 11"x17" PIDt ©2016, SUN—ka t I 1 V/ r TLY PIHEETTI.LE This document along with the ideas and designs presented herein are the property of SU Ntworks and is not to be used in whole or in part withol SITE LAYOUT PV -02 e express written consent of SUNworks. I CIRCUIT �(TYP'OF2)r` O INVERTER TO SOLAR LOAD CENTER (TYP. 2; O SOLAR LOAD CENTER TO POI . COMPLY WITH CALIFORNIA ELECTRICAL CODE- ARTICLE 250 REQUIREMENTS FOR GROUNDING AND BONDING r—(TYPI—CA L OF 2) — — — — — — — — — — — — — — — — — — I 2 I INVERTER INTEGRATED FUSES AND 'AC/DC DISCONNECT I 15A 10 PV MODULES 10 PV MODULES C> �1 MOUNTING STRUCTURE V L ----------------------J COMPLY WITH CALIFORNIA ELECTRICAL CODE- ARTICLE 690 REQUIREMENTS FOR SOLAR PHOTOVOLTAIC SYSTEMS NOTES: • CONDUCTOR SIZED PER NEC 230.42(B)PROPERTY OF SUNWOSZS INC. • PV MODULE GROUNDING PER RAPID RACK INSTALLATION MANUAL. /J • ALL GROUNDING DEVICES ARE UL RECOGNIZED/CERTIFIED. ►I�D • ALL TAP DEVICES ARE UL LISTED. INSTALLATION PER Sin V� VV MANUFACTURERS INSTALLATION MANUALS. 15 Pepsi Way Durham, CA 95938 Ph:530.345.9910 Fax:530.345.3074 Proviri,, readily accessible capability to circuit breaker(s), disconnect(s), fuse(s),switch(es) and their accessories as required and defined in California Electrical Code (N) SOLAR LOAD CENTER 100A, 240V, 3W, 10 NEMA 3R 35A INVERTER #1 1-1 35A INVERTER #2 ----- — — � —F - - V — \:J Label, circuit breaker(s), disconnect(s), fuse(s),switch(es) and their accessories, to identify their location and or equipment I r Cn COMPLY WITH 2013 CALIFORNIA o ELECTRICAL CODE -ARTICLE 705 ------ - W REQUIREMENTS FOR Interconnected Electric PowerProduction Systems TO UTILITY TRANSFORMER o' EQUIPMENT SCHEDULE OCP TAG DESCRIPTION COMPONENT COMMENTS 1Q BRANCH OF PV MODULES (40) HANWHA Q.PLUS L -G4.2 335 SEE DIAGRAM FOR MODULES PER STRING VOLTAGE DROP INVERTERS (2) SOLECTRIA RENEWABLES PVI-520OTL (240) INTEGRATED OCP AND AC/DC DISCONNECT 30 (N) SOLAR LOAD CENTER 100A RATED, 240VAC,10,3W, WITH MAIN LUG iN ® (N) AC DISCONNECT 100A RATED, 240VAC,10,3W, 70A FUSES CUTLER -HAMMER DH365NRK 0 - (N) MAIN SERVICE PANEL 225A RATED, 240VAC,10,3W WITH 2O0A MAIN BREAKER SOLAR READY SERVICE PANEL I CIRCUIT �(TYP'OF2)r` O INVERTER TO SOLAR LOAD CENTER (TYP. 2; O SOLAR LOAD CENTER TO POI . COMPLY WITH CALIFORNIA ELECTRICAL CODE- ARTICLE 250 REQUIREMENTS FOR GROUNDING AND BONDING r—(TYPI—CA L OF 2) — — — — — — — — — — — — — — — — — — I 2 I INVERTER INTEGRATED FUSES AND 'AC/DC DISCONNECT I 15A 10 PV MODULES 10 PV MODULES C> �1 MOUNTING STRUCTURE V L ----------------------J COMPLY WITH CALIFORNIA ELECTRICAL CODE- ARTICLE 690 REQUIREMENTS FOR SOLAR PHOTOVOLTAIC SYSTEMS NOTES: • CONDUCTOR SIZED PER NEC 230.42(B)PROPERTY OF SUNWOSZS INC. • PV MODULE GROUNDING PER RAPID RACK INSTALLATION MANUAL. /J • ALL GROUNDING DEVICES ARE UL RECOGNIZED/CERTIFIED. ►I�D • ALL TAP DEVICES ARE UL LISTED. INSTALLATION PER Sin V� VV MANUFACTURERS INSTALLATION MANUALS. 15 Pepsi Way Durham, CA 95938 Ph:530.345.9910 Fax:530.345.3074 Proviri,, readily accessible capability to circuit breaker(s), disconnect(s), fuse(s),switch(es) and their accessories as required and defined in California Electrical Code (N) SOLAR LOAD CENTER 100A, 240V, 3W, 10 NEMA 3R 35A INVERTER #1 1-1 35A INVERTER #2 ----- — — � —F - - V — \:J Label, circuit breaker(s), disconnect(s), fuse(s),switch(es) and their accessories, to identify their location and or equipment I r Cn COMPLY WITH 2013 CALIFORNIA o ELECTRICAL CODE -ARTICLE 705 ------ - W REQUIREMENTS FOR Interconnected Electric PowerProduction Systems TO UTILITY TRANSFORMER J I I 200A/21a o' j-1 OCP FG LU i CURRENT CARRYING CONDUCTORS w 70Al2P w m z VOLTAGE DROP a r> CURRENT X 1.25 (A) Lu U o ^OfW DISTANCE (FT) a N iN a0 O N w z J I I 200A/21a W Q 0 J PERMIT# �� �✓ �� BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED T!— TAG FOR CO CO1 Y 1 1 DATE I CONDUCTOR, CONDUIT AND VOLTAGE DROP SCHEDULE CONTINUOUS j-1 OCP FG CONDUCTOR REQUIRED CURRENT CARRYING CONDUCTORS U-1 EGC/GEC CONDUIT ONE WAY VOLTAGE DROP CURRENT (A) CURRENT X 1.25 (A) wNU ^OfW DISTANCE (FT) (% AT 75°C) T(amb) RACEWAY !2 �\ w Q 0 - 0 0 N W Q 0 J PERMIT# �� �✓ �� BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED T!— TAG FOR CO CO1 Y 1 1 DATE I CONDUCTOR, CONDUIT AND VOLTAGE DROP SCHEDULE CONTINUOUS CONTINUOUS OCP DERATES CONDUCTOR REQUIRED CURRENT CARRYING CONDUCTORS CONDUCTOR AMPACITY (A) EGC/GEC CONDUIT ONE WAY VOLTAGE DROP CURRENT (A) CURRENT X 1.25 (A) SIZE VOLTAGE (V) DISTANCE (FT) (% AT 75°C) T(amb) RACEWAY AMPACITY(A) SIZE(min) TYPE (PER NEC 310.15) SIZE (min) TYPE SIZE TYPE 0 conductor perrun 9.54 11.93 15 0.82 0.80 18.19 #10 AWG PV WIRE 35 #10AWG(t.y) Bare CU 1 Tray/in free 4 373 80 0.51% #6AwG solid air 27.50 34.38 35 0.82 1.00 41.92 #8 AWG THWN 2 (or eq.) 50 #10 AWG THWN-2 (or eq.) V EMT/PVC 2 240 10 0.18% THWN-2 THWN-2 55.00 68.75 70 0.82 1.00 83.84 #4AWG (or eq.) 85 #8 AWG (or eq.) 1-1/2" 2 240 10 0.14% This document along with the ideas and designs presented herein are the property of SUN Norks and is not to be used in whole PROJECT INFORMATION OWNER NAME NEW HOPE MISSIONARY BAPTIST CHURCH ADDRESS 5640 LINCOLN BOULEVARD CITY OROVILLE, CA 95966 AUTHORITY HANNG JURISDICTION BUTTE COUNTY ASSESSORS PARCEL NUMBER 78-190-020 SYSTEM INFORMATION SIZE 13.4 KW RACKING TYPE ROOF MOUNT INTERCONNECTION TYPE 200A - 240V GRID TIED TOTAL MODULES (40) HANWHA Q.PLUS L -G4.2 335 INVERTER 2) SOLECTRIA RENEWABLES PVI-5200TL (240) DESIGNEEWS SIGNATURE 6�6 PROJECT NO. DRAWN BY: 16-055 EC DATE APPROVED BY: 10/13/2016 REVISION SCHEDULE NO. DATE DESCRIPTION 1 2 3 4 1 1 inch I Scale to Confirm 11"x17" Plot ©201a. SUNworkt SHEETTIT E: ELECTRICAL DIAGRAM SHEET NUMBER'. PV -03 or in part without the express written consent of Si DESIGN TEMPERATURES LOWEST EXPECTED TEMPERATURE AVERAGE HIGH TEMPERATURE 35°C PV MODULE ELECTRICAL SPECIFICATIONS MANUFACTURER HANWHA MODEL Q.PLUS L -G4.2 335 PMAX (NOMINAL OUTPUT POWER) 335 W VMP (VOLTAGE AT PMAX) 37.33 V IMP (CURRENT AT PMAX) 8.97 A VOC (OPEN CIRCUIT VOLTAGE) 46.81 V ISC (SHORT CIRCUIT CURRENT) 9.54 A VOC TEMPERATURE COEFFICIENT -0.29 %rc DC SOURCE INFORMATION the property of SUNWorxs and is not to be used in whole or in MANUFACTURER SOLECTRIA RENEWABLES NUMBER OF PV MODULES 40 MODULES MAXIMUM MODULES PER STRING 10 MODULES MAX. STRING VOC (10 x VOC) 468.1 V 48 A MPPT_MIN AT FULL POWER 200 V MAXIMUM DC SYSTEM VOLTAGE: 500 V MAXIMUM DC VOLTAGE Max. String Voc x {1 + [(T low- 25) x T coeff.]): 468.1 x {1 + [(-3 - 25) x -0.0029]) = 506.1 V INVERTER ELECTRICAL SPECIFICATIONS the property of SUNWorxs and is not to be used in whole or in MANUFACTURER SOLECTRIA RENEWABLES MODEL PVI-520OTL NOMINAL AC POWER 5.2 INV NOMINAL OUTPUT VOLTAGE 240 V NOMINAL OUTPUT CURRENT 27.5 A OCP SIZE 48 A MPPT_MIN AT FULL POWER 200 V MPPT MAX AT FULL POWER 500 V MAXIMUM DC VOLTAGE 600 V SIGNAGE: PER CEC 110.16, CEC 110.21, CEC 110.24 LOCATION TO BE PLACED AS SPECIFIED AND WHERE DEEMED REQUIRED/NECESSARY BY INSPECTORS AND/OR SENIOR CONSTRUCTION MANAGER OR ENGINEER ALL EQUIPMENT LOCATIONS U'J/Aj;7Q 6,& • e: AC DISCONNECT , !a'+ `' wl i• 1; -;480 77 r. INTERIOR/EXTERIOR DC CONDUIT (EVERY 10') (t -Lm-) 4-9161-x- alii!!Jl ] METER/MAIN AND SOLAR LOAD CENTER SOLAR LOAD CENTER ru�rrrsl &t&';1 STRING INVERTER rji c�- • • � r ��r 4 � r r*' 1414 r�o'.: •'�c'•1�• r �r � r' PERMIT# BUTTE COUNTY DEVELOPMENT SERVICES REDVI EWED FOR CODE COWPLIA C DATE-- 11� BY 15 Pepsi Way Durham, CA 95938 Ph:530.345.9910 Fax:530.345.3074 PROJECT INFORMATION ONMER NAME NEW HOPE MISSIONARY BAPTIST CHURCH ADDRESS 5640 LINCOLN BOULEVARD CITY OROVILLE, CA 95966 AUTHORITY HAVING JURISDICTION BUTTE COUNTY ASSESSORS PARCEL NUMBER 76-190-020 SYSTEM INFORMATION SIZE 13.4 KW RACKING TYPE ROOF MOUNT INTERCONNECTION TYPE 200A - 240V GRID TIED TOTAL MODULES (40) HANWHA Q.PLUS L -G4.2 335 INVERTER 2) SOLECTRIA RENEWABLES PVI-520OTL (240) DESIGNER'S SIGNATURE / I' the property of SUNWorxs and is not to be used in whole or in part without the express PROJECT NO. 16-055 DRAWN BY: EC DATE 10/13/2016 APPROVED BY: REVISION SCHEDULE NO. DATE DESCRIPTION 1 2 3 4 1 inch ScaleI to Confirm 11"x17" Plot 02016, SUN'rorkr -r TITLE ELECTRICAL CALULATIONS :T NUMB -R'. PV -04 This document along with the ideas and designs presented herein are the property of SUNWorxs and is not to be used in whole or in part without the express written consent of SUN-+Orks. The UNTUM solar module Q.PLUS L -G4.2 with power classes up to 340 Wp is the strongest module of its type on the market globally. Powered by 72 Q CELLS solar cells Q.PLUS L -G4.2 was specially de- signed for large solar power plants to reduce BOS costs. But there is even more to our polycrystalline modules. Only Q CELLS offers German engineering quality with our unique triple Yield Security. LOW ELECTRICITY GENERATION COSTS G Higher yield per surface area and lower BOS costs thanks to higher power classes and an efficiency rate of up to 17.4 %. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti -PID Technology', Hot -Spot -Protect and Traceable Quality Tra.Qrm. LIGHT -WEIGHT QUALITY FRAME High-tech aluminum alloy frame, certified for high snow (5400 Pa) and wind loads (2400 Pa). A RELIABLE INVESTMENT ` Inclusive 12 -year product warranty and 25 -year linear performance guarantee2. THE IDEAL SOLUTION FOR: solar power plants 4, QCELLS PV Y111 aanmm TOP BRAND nleorr > 2015 Phntnn acetLS Ent polyclystalliee colt --dule 2017 e nea223s nl .r+.ar I APT test conditions: Cells at -1000V against grounded, with conductive me- tal foil covered module surface, 25°C, 168h 2 See data sheet on rear for further information. Engineered in Germany Q�t ��; CEL LS 1 .. I I I I first year. Thereafter max. 0.6% degra- 7 77 7A _. Format 78.5 in x 39.4 in x 1.38 in (including frame) 1 _ I _ ' _ ' 1 ' '_ '_ '_ -` -�-`--`--`-� -� -� -n 10 years. 5 0 ---r--'--�--'--------�I--� At least 83 % of nominal power after (1994 mm x 1000 mm x 35 mm) Temperature Coefficient of IS, 25 years. C e ---r--r--r-r--r--1--r-�--� Temperature Coefficient of Vx All data within measurement tolerances. Weight 52.9 Ib (24 kg) m xo °oo m coo rao rm too loco Full warranties in accordance with the Normal Operating Cell Temperature NOCT ['FI 113 t 5.4 (45 t 3'C) warranty terms of the Q CELLS sales Front Cover 0.13 in (3.2 mm) thermally pre -stressed glass with anti -reflection technology Maximum System Voltage Vs. IV] Back Cover Composite film Safety Class II Maximum Series Fuse Rating [A DCI 15 Frame Anodised aluminum C / Type 1 Max Load (1102 [lbs/ft] 75 (3600 Pa) Permitted module temperature Cell 6 x 12 solar cells .` on continuous duty (40 °C up to +85 °C) )unction box 3.35-4.13 in x 2.36-3.15 in x 0.59-0.67 in (85-105 mm x 60-80 mm x [lbs/ft'l 33 (1600 Pa) a see installation manual 15-17 mm), Protection class z IP67, with bypass diodes ., . , a... ,,a-,,,•,,,.°•, , IEC 61215 (Ed.2);IEC 61730 (Ed. 1), Application class A Cable 4 mm2 Solarcable; (+) 2- 47.24in (1200 mm), (-) 2_ 47.24in (1200 mm) Number of Modules per Pallet - 29 This data sheet complies with DIN EN 50380. Connector Amphenol H4, IP68 22 ,. I_=j°""°^" Pallet Dimensions ( L x W x H) 81.3 x 45.3 x 46.9 in x 1150 x 1190 mm) `(2065 DVE AE POWER CLASS 320 325 330 335 340 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5W / -OW) Power at MPP' P„PP [W] 320 325 330 335 340 Short Circuit Current` Ise [A] 9.39 9.44 9.49 9.54 9.59 E E Open Circuit Voltage• voo IV] 46.17 46.43 46.68 46.94 47.20 Current at MPP' INP, [A] 8.79 8.85 8.91 8.97 9.03 Voltage at MPP* VwP [V] 36.39 36.70 37.02 37.33 37.63 Efficiencyz n I%] 2-16.0 216.3 2_16.5 2-16.8 2-17.1 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NOCa Power at MPP' P_ [W] 237.2 241.0 244.7 248.4 252.1 E Short Circuit Current* Ise [A] 7.57 7.61 7.65 7.69 7.73 E Open Circuit Voltage• V°e IV] 43.08 43.32 43.56 43.81 44.05 Current at MPP` INPP [A] 6.89 6.94 6.99 7.04 7.09 Voltage at MPP` VwP IV] 34.44 34.72 35.01 35.29 35.56 11000 W/m2, 25°C, spectrum AM 1.513 ' Measurement tolerances STC t3%; NOC ±5% 3800 W/m2, NOCT, spectrum AM 1.5G -typical values, actual values may differ Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE At least 97% of nominal power during .. I I I I first year. Thereafter max. 0.6% degra- z 1m ---;--'- ---------- -- 1 1 1 1 1 1 dation per year. At least 92 %of nominal power after '" 1 _ I _ ' _ ' 1 ' '_ '_ '_ -` -�-`--`--`-� -� -� -n 10 years. 5 0 ---r--'--�--'--------�I--� At least 83 % of nominal power after Temperature Coefficient of IS, 25 years. C e ---r--r--r-r--r--1--r-�--� Temperature Coefficient of Vx All data within measurement tolerances. p ,m m xo °oo m coo rao rm too loco Full warranties in accordance with the Normal Operating Cell Temperature NOCT ['FI 113 t 5.4 (45 t 3'C) warranty terms of the Q CELLS sales IRRADIANCE [wim7 e 1° 1e n organisation of your respective country. YEARS The typical change in module efficiency at an irradiance of 200 W/m2 in relation ..want:ol<esla,.. sa-.mu' to 1000 W/m2 (both at 25°C and AM 1.5G spectrum) is -1.5% (relative). TEMPERATURE COEFFICIENTS Temperature Coefficient of IS, a [%/K] +0.04 Temperature Coefficient of Vx R [%/K] -0.29 Temperature Coefficient of P_ Y [%/K] -0.40 Normal Operating Cell Temperature NOCT ['FI 113 t 5.4 (45 t 3'C) 1. ,• , Maximum System Voltage Vs. IV] 1500 (IEC) / 1500 (UL) Safety Class II Maximum Series Fuse Rating [A DCI 15 Fire Rating C / Type 1 Max Load (1102 [lbs/ft] 75 (3600 Pa) Permitted module temperature -40'F up to +185°F on continuous duty (40 °C up to +85 °C) Load Rating ll [lbs/ft'l 33 (1600 Pa) a see installation manual ! 1 177711 1 IEC 61215 (Ed.2);IEC 61730 (Ed. 1), Application class A Number of Modules per Pallet - 29 This data sheet complies with DIN EN 50380. Number of Pallets per 40' Container 22 00',, Pallet Dimensions ( L x W x H) 81.3 x 45.3 x 46.9 in x 1150 x 1190 mm) `(2065 DVE cs .7.1 Pallet Weight 1671 lbs (758 kg) NOTE: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hanwha Q CELLS USA Corp. 300 Spectrum Center Drive, Suite 1250, Irvine, CA 92618, USA I TEL +1949 748 59 96 IT.IyIAI} cl-c�us a� /lglls.dory.� PERMIT# tSC`�7Lt �1/E =ltQ C ���� BUTTE COUNTY DEVELOPMENT RVICE5 Engineered in Germany REVIEWED . C0,9E COMPLIANCE [IAT€==-�I 1% DY ASA SOLECTRIA SOLAR 1 -PH TRANSFORMERLESS STRING INVERTERS �M,Yaskawa - Solectria Solar's PVI 3800TL, PVI 520OTL, PVI 6600TL, and PVI ic7ai i °. 760OTL are compact, transformerless, single-phase inverters with the highest peak and CEC efficiencies in the industry. These inverters come standard with an integrated DC disconnect, DC arc -fault detection and interrupt, 1 or 2 MPP 4im. quiwir oke tracker(s), and a user -interactive LCD and keypad. Their small and lightweight 'AiLi. -4t4"iV0 design make for quick and easy installation and maintenance. They have an 4,)47 Jk$..jWjaW i innovative passive cooling design which eliminates the need for fans in the inverter. These inverters include an enhanced DSP control, comprehensive protection functions, and advanced thermal design enabling highest reliability k and uptime. Any PVI 3800-760OTL may be purchased with our Rapid Shutdown .� Combiner to comply with NEC 2014. q YASKAWA sc,LEGTRIA50LAR I, YASKAWA SOLEGTRIASOLAR t I_ x, N.lRTe� SOLECTRIA.COMC(�'TousI s" v z ...-'•:��ripN,r,*'..+r.T.ti'A'eATN,'%Y'wu,°�ea^ic�xn^.'m:4'rx.e-'.'R"�,ae�,;x1NW'...tJ'+a*'J".%i, s� r Yc*"'m'bxr.Y'nN4#FPs' r x.m.,°.. �.svi4ie�5'i."^"i"R.'fiw'.T•X`�,F>,' ^�'rt*:q 1 V O Absolute Maximum Open Circuit Voltage 600 VDC � o Operating Voltage Range 120.550 VDC A MPPT Input Voltage Range 200-500 VDC MPP Trackers 1 2 Maximum Operating Input Current 20A 15 A per MPP tracker 18 A per MPP tracker 20 A per MPP tracker c Maximum Input Short Circuit Current (Isc x 1.25) 24A 48 A (24 A per MPP tracker) Start Voltage 150V m Nominal Output Voltage 208 or 240 VAC,1-Ph AC Voltage Range •12%/+10% 208 VAC 3328 W 5200 W 6600 W 6656W Continuous Output Power 240 VAC 3800 W 5200 W 6600 W 7600 W Maximum Continuous Output Current 16A 27.5 A 32A Maximum Backfeed Current 0 A a Nominal Output Frequency 60 Hz Output Frequency Range 59.3-60.5 Hz Power Factor Unity, > 0.99 e Total Harmonic Distortion (THD) QD Rated Load <3%M77 ; 3 AZT"= Peak Efficiency 98.3% 6 CEC Efficiency 97.5% Tare Loss <i W17 o =7T Ambient Temperature Range (full power) -130F to +122oF (-25oC to +50*0 Storage Temperature Range -40oF to +1850F (-40oC to +85*0 Relative Humidity (non -condensing) 0-100% Operating Altitude 6,562 ft/2000 m Optional SolrenView Web -based Monitoring External Optional Revenue Grade Monitoring External External Communication Interface RS -485 Safety Listings & Certifications UL 1741/IEEE 1547, UL 16998, CSA C22.2#107.1, FCC part 15 A&B Testing Agency ETL CSA 3 r. _ Standard 10 year Optional Extended warranty not available dBA (Decibel) Rating (45 dBA @ 3 m DC Disconnect Standard, fully -integrated Dimensions (H x W x D) 17.5 x 15.8 x 8.5 In. 26.8 x 15.8 x 8.5 In. (445 x 402 x 216 mm) (681 x 402 x 216 mm) Weight 43 lbs (19.5 kg) 65 lbs (29.5 kg) Enclosure Rating Type 4 + Salt Mist Corrosion Protection Enclosure Finish Aluminum PERMIT #�4O '— BUTTE COUNTY DEVELOPMENT SERVICES REFI EWED FOR CODE COMP CE YASKAVIYA DATE�/dr 3 SOLECTRIASOLAR www.solectria.com I inverters@solectria.com 1 978.683.9700 SOUR APPENDIX G� System Certification .... ------------------------------------------------------------------------------------------------------------------------- The SOLARMOUNT system has been certified and listed to the UL 2703 standard (Rack Mounting Systems and Clamping Devices for Flat -Plate Photovoltaic Modules and Panels). This standard included electrical grounding, electrical bonding, mechanical Load and fire resistance testing. In conducting these tests, specific modules are selected for their physical properties so that the certifications can be mostly broadly applied. The following lists the specific modules that were tested and the applicability of those certifications to other modules that might come onto the market. In addition to UL 2703 certification, Unirac performs internal testing beyond the requirements of certification tests in order to establish system functional Limits, allowable loads, and factors of safety. These tests include functional system tests, and destructive Load testing. Mechanical Load Test Modules System Level Fire Classification The modules selected for UL 2703 mechanical Load testing were selected to The system fire class rating requires installation in the manner specified in the represent the broadest range possible for modules on the market. The tests SOLARMOUNT Installation Guide. SOLARMOUNT has been classified to the system Level performed cover the following basic module parameters: fire portion of UL 1703. This UL 1703 classification has been incorporated into our UL • 60, 72, and 96 celL framed modules 2703 product certification. Class A system level fire performance is inherent in the • Frame thicknesses greater than or equal to 1.0 mm SOLARMOUNT design, and no additional mitigation measures are required. The fire • Basic single and double wall frame profiles (some complex classification rating is only valid on roof pitches greater than 2:12 (slopes : 2 inches per frame profiles could require further analysis to determine foot, or 9.5 degrees). There is no required minimum or maximum height Limitation applicability) above the roof deck to maintain the system fire rating for SOLARMOUNT. Module Types • Clear and dark anodized aluminum frames & System Level Fire Ratings are listed below: • Certification Loads: 50 psf up, 112 psf down PERMIT # _in��-2:�? BUTTE COUNTY DEVELOPMENT SERVICES NEIVIIEVEiJ FOR CODE COMPLI NCE DATE I l t BY Rail Tested Modules Module Manufacturer Model/Series CentroSolar E -Series 60 Cell, T -Series 60 Cell Hyundai HiS-MxxxMI, HiS-SxxxMI SunPower SPR -E20-327 Trina I TSM-PA05.08 PERMIT # _in��-2:�? BUTTE COUNTY DEVELOPMENT SERVICES NEIVIIEVEiJ FOR CODE COMPLI NCE DATE I l t BY Rail Module or Series System Level Rail Module Mitigation CentroSolar America Module Type I ET Solar ET AC Module, ET Module Hanwha SolarOne HSL 60 Type MG Series, RG Series, RW Series Fire Ratinq Direction Orientation Required Standard Type 1, Type 2, Phono Solar Technology East-West Landscape OR 60 -Cell Modules Rail Type 3, & Type 10 YP YP Class A, B, & C North-South Portrait None Required Light Rail Type 1 & Type 2 Class A, B, & C East-West Landscape OR None Required Trina PA05, PD05 TSMC Solar North-South Portrait Panda 60, YGE 60, YGE-Z 60 7771: 11"OU " APPEND iSystem Certificatio Electrical Bonding and Grounding Test Modules The list below is not exhaustive of compliant modules but shows thos have been evaluated and found to be electrically compatible with the SOLARMOUNT system. Manufacturer Module or Series AU Optronics (BenQ Solar) PM Series Canadian Solar CSSA-M, CS6P-M, CS6P-P, CS6X-P, CSX -P, ELPS CS6A-MM, ELPS CS6P-MM CentroSolar America C -Series, E Series ET Solar ET AC Module, ET Module Hanwha SolarOne HSL 60 Hyundai Heavy Industries MG Series, RG Series, RW Series Kyocera KD -F Series LG Electronics MONO NEON, MONO X Panasonic VBHNxxxSA06/SA06B/SAll/SA11B Phono Solar Technology Standard Modules Renesola 60 -Cell Modules Sharp ND-240QCJ, ND-250QCS, ND-Q235F4 SolarWorld Sunmodule Plus, Sunmodule Pro, Sunmodule Protect Sun Edison/MEMC F -Series, R -Series Suniva MV Series, optimus'" Series SunPower AC, E -Series, Sig Black, X -Series Suntech STP"XXX" Trina PA05, PD05 TSMC Solar TS -150C2 CIGS Yingli Panda 60, YGE 60, YGE-Z 60 PAGE GI The modules selected for UL 2703 bonding and grounding testing represent the broadest possible range of modules on the market. The tests were performed for each specific bonding Location using representative module frame profile sections. The tests performed cover the following basic module parameters: • 60, 72, and 96 cell framed modules • Frame thicknesses greater than or equal to 1.0 mm • Basic single and double wall frame profiles (some complex frame profiles could require further analysis to determine applicability) • Clear and dark anodized aluminum frames • The frame profile must not have any feature that might interfere with the bonding devices that are integrated into the racking system UL 2703 Certification Marking Label Unirac SOLARMOUNT is listed to UL 2703. Marking Labels are shipped with the Midclamps. After the racking system is fully assembled, a single Marking Label should be applied to the SOLARMOUNT rail at the edge of the array. Note: The sticker label should be placed such that it is visible, but not outward facing. �IIL�IAiwM UNIRAC SOLARMOUNT PROTECTED MIAND INTERNATIONAL PATENTS MMMUCIUREDIMLMIQUERQUE,IMM ILM14 ruv n wmd erten' Fire Class Rath. Sea Installation UL SU 2703 Mstruttio" for Installation Requirements to PAGE G2 1 1SOLAR F] EDAPPENDIX H� L -1 171 MOUNT Technical ata Sheets .................................................................................................................................-.-.--.---.. END -END Midclamp and Endclamp Loads per Module END -MID MID -MID MID -END Module Condition Definitions: END -END: The END -END module shown above, correlating with the loads below, indicates a module that is secured by 4 Endclamps on 2 rails. END-MID/MID-END: The END -MID and MID -END modules shown above, correlating with the loads below, indicate modules that are secured by 2 Endclamps and 2 Midclamps on 2 rails. MID -MID: The MID -MID module shown above, correlating with the loads below, indicate a module that is properly secured by 4 Midclamps on 2 rails. Midclamp and Endclamp Loads per Module Clip (SM HD Only) Direction Allowable Load (lbs) SM HD Rail Loading Condition (with Respect to the Rail P ) Allowable Load (lbs) End -Mid & End End Mid -End Mid Mid Design Load (lbs) End -Mid & End -End Mid -End Mid Mid SM/SM HD Z+, Tension 1836 1751 1666 2780 2726 2672 Y±,Transverse* 178' 315* 428 269* 476` 647 X±, Sliding 244 244 850 368 368 1286 Y±, Transverse w/33mm Module 67 248 428 102 373 647 SM LT Z+, Tension 1260 1234 1208 1908 1867 1826 Y±, Transverse* 139* 225* 419 211* 340* 634 X±, Sliding 266 266 840 402 402 1270 Y±, Transverse w/33mm Module 67 225 1 419 102 340 634 FU" Ud"Uvl7Jse ioaas assonatea wim using L. tnaciamps and 33 mm Modules, please see 'Y±,Transverse w/33mm Module' Midclamp: Part No. - 302027C, 302027D, 302028C, 302028D, 302029C, 302029D. Material - Stainless Steel 300 Series. Ultimate Tensile Strength - 85 ksi. Finish - Clear or Black Oxide. Weight - 0.05 lbs (23 g). Endclamp: Part No. - 302021C, 302021D, 302022C, 302022D, 302023C, 302023D, 302024C, 302024D, 302025C, 302025D, 302026C, 302026D. Material - 6000 Series Aluminum Alloys. Ultimate Tensile Strength - 38 ksi. Yield Strength - 35 ksi. Finish - Clear or Dark Anodized. Weight - 0.06 lbs (26 g) "'NOTE: See NOTES on Page H2. PAGE Hl PERMIT#alb- BUTTE COUNTY DEVELOPMENTSERViCES SOi REVIEWED OR Dn' 711 D ll APPENDIX H � ATE � BY Technical at 1 a ets 1 c. SOLARMOUNT BOTTOM MOUNTING CLIP (SM HD ONLY) SnI ARmni INT I -FnnT Bottom Mountin Clip (SM HD Only) Direction Allowable Load (lbs) SM HD Design Load (lbs) SM HD X±, Sliding 27 41 Y±, Transverse 329 497 Z+, Tension 686 746 Part No. 302000C Bottom Mounting Clip Material: 6000 Series Aluminum Alloys Ultimate Tensile Strength: 38 ksi, Yield Strength: 35 ksi Finish: Clear Anodized /-; Z X 0 Y Part No. 304001C, 304001D L -Foot material: 6000 Series Aluminum Alloys Ultimate Tensile: 38 ksi, Yield: 35 ksi Finish: Clear or Dark Anodized L -Foot Weight: 0.215 lbs (98g) NOTES: Allowable and design loads are valid when components are assembled according to authorized UNIRAC documents. For the beam to L -Foot connection: Assemble with one Unirac 3/g'-20 T -Bolt and one 3/8'-20 ASTM F594 serrated flange nut. Use anti -seize and torque the Midclamp, Endclamp, and Bottom Mounting Clip to 10 ft -Lbs. Use anti -seize and torque the L -Foot to 30 ft -lbs. Values for the L -Foot and Bottom Mounting Clip represent the capacity of a single part when used with a SOLARMOUNT series rail to retain a module in the direction indicated. Assemble Midclamp and Endclamp with one Unirac'/a =20 T -Bolt and one Ya' -20 ASTM F594 serrated flange nut. SM = SOLARMOUNT Standard Rail, SM HD = SOLARMOUNT Heavy Duty Rail, SM LT = SOLARMOUNT Light Rail PAGE H2 L -Foot with 3/8' T -Bolt Direction Allowable Load (lbs) Design Load (lbs) SM/SM HD SM LT SM/SM HD SM LT X±, Sliding 565 594 854 898 Y ±, Transverse 146 `- 172 220 261 Z +, Tension 938 603 1419 - 911 Z -,Compression 1357, 1297 2052 1962 Part No. 304001C, 304001D L -Foot material: 6000 Series Aluminum Alloys Ultimate Tensile: 38 ksi, Yield: 35 ksi Finish: Clear or Dark Anodized L -Foot Weight: 0.215 lbs (98g) NOTES: Allowable and design loads are valid when components are assembled according to authorized UNIRAC documents. For the beam to L -Foot connection: Assemble with one Unirac 3/g'-20 T -Bolt and one 3/8'-20 ASTM F594 serrated flange nut. Use anti -seize and torque the Midclamp, Endclamp, and Bottom Mounting Clip to 10 ft -Lbs. Use anti -seize and torque the L -Foot to 30 ft -lbs. Values for the L -Foot and Bottom Mounting Clip represent the capacity of a single part when used with a SOLARMOUNT series rail to retain a module in the direction indicated. Assemble Midclamp and Endclamp with one Unirac'/a =20 T -Bolt and one Ya' -20 ASTM F594 serrated flange nut. SM = SOLARMOUNT Standard Rail, SM HD = SOLARMOUNT Heavy Duty Rail, SM LT = SOLARMOUNT Light Rail PAGE H2 1 APPENDIXH 1 '.......................................................................................... --- ---- ' Technical Sheets.,- - - - - - - - - - - .upuluaa �-uLAKMUUNT Light SOLARMOUNT Rail Profile 2 SOLARMOUNT HD BEAM HEIGHT 1.70 2.573.00 Units APPROX WEIGHT 0.491m 0.728 CROSS SECTION AREA 0.409 0.625 1.271 ifinz SECTION MODULUS (X-AXIS) 0.15 0.363 1.059 j SECTION MODULUS (-AXIS) Y 0.067 0.113 0.898 in 3 MOMENT OF INERTIA (X-AXIS) 0.13 0.467 0.221 0.221 in MOMENT OF INERTIA (Y-AXIS) 0.026 0.045 1.45 in RADIUS OF GYRATION (X-AXIS) 0.564 0.865 0.267 4 in RADIUS OF GYRATION (Y-AXIS) 0.2540.502 0.269 1.17 in in PAGE H3 n 7 -10 1 APPEND X I1 --------------------------------------------------------____________________.____._____________.___.._____ ------OUNT SOLAR 1_ ----- -------- The SOLARMOUNT Installation Guide and system certifications are equally applicable to SOLARMOUNT HD and Light rail. Unless otherwise noted, installation procedures for both are equivalent and sufficient to maintain system certifications. For maximum spans and cantilevers specific to SOLARMOUNT HD and Light rail, please refer to Appendix C and the SOLARMOUNT Installation Guide. Clip Bottom Mounting with SOLARMOUNT HD Rail: Bottom mounting is no longer possible with standard SOLARMOUNT or Light rail, however, SOLARMOUNT HD still accommodates this mounting method. Should you elect to use bottom mounting clips to secure modules, please refer to the procedure below. NOTE: Bottom mounting of modules does not provide module bonding through clips and is not covered under the current UL 2703 certification. Wrench `Recommended size torque (fit -46s) /.' hardware ifs' 10 2/e hardware 44/,j- 30 Nate: Torque spedfrcaCons do not apply to fog bo@ tonnectlanL ' Wnh antl-sefze PERMIT# 01162=2 ?�1�3 BUTTE COUNTY DEVELOPMENT SERVICES REVIEWE® FOR CO®E CO1`01PLIA CE DATE 1 l %1 l (2 By PAGE Il ell - I 1 I I U�_j Top Mounting UniRac Grounding Clips and WEEBLugs - 225.6 UGC -1 Figure 28. UGC -1 layout for even and odd number of modules in row. "x" denotes places to install UGC -1. Even Number of Modules in row Odd Number of Modules in row •�� Pub 110 UNIRAC 2011 June 2011 ■ ■ ® 2011 by Unirac, Inc. A HILTI GROUP COMPANY All rights reserved. Page 2 C:' UNI RAC Installation Sheet 225.6 Unirac Grounding Clips and wEEBLugs 10 year limited Product Warranty See http://www.unirac.com for current warranty documents and information. PERMIT#_�I — 2� 1 BUTTE COUNTY DEVELOPMENT SERVICES REVIEWE® FOR CODE COMPLIANCE QAT� 11-1 YOUR UNIRAC DISTRIBUTOR SOLIGENT Soligent www.soligent.net J www.soligent.net ®©®1411 Broadway Boulevard NE new U N I RAC Albuquerque NM 871oz-1545 USA Ar Top �T� Vlamps r i Module I � 1 1 T -^bolt Nib C ��I us i �' .41. UGC -1 e�--le Figure 26. Slide UGC -1 grounding into Intertek 1 I clip top mountingslotof rail I Torque modules in place on top of Conforms to ____ _ �.__'_ _ � clip. Nibs will penetrate rail anod- uL svnaard 4e7 -. y ization and create grounding path c through rail (see Fig. 3, reverse side). SolarMount® rail (any type) WEEB Lug Figure 27. Insert a bolt in the aluminum rail or through the clearance hole in the stainless steel flat washer. Place the stainless steel Ids►. flat washer on the bolt oriented so the dimples will contact the -a r� aluminum rail. Place the lug portion on the bolt and stainless steel flat washer. Install stainless steelflat washer, lock washer and nut. WEEBLug Tighten the nut until the dimples are '^ �a completely embedded into the rail { and lug. The embedded dimples make Stainless Steel Flat a gas-tight mechanical connection Washer (WEEB) and ensure good electrical connection between the aluminum rail and the Clips and lugs are sold separately. lug through the WEEB. Mount® rail(any type) Figure 28. UGC -1 layout for even and odd number of modules in row. "x" denotes places to install UGC -1. Even Number of Modules in row Odd Number of Modules in row •�� Pub 110 UNIRAC 2011 June 2011 ■ ■ ® 2011 by Unirac, Inc. A HILTI GROUP COMPANY All rights reserved. Page 2 C:' UNI RAC Installation Sheet 225.6 Unirac Grounding Clips and wEEBLugs 10 year limited Product Warranty See http://www.unirac.com for current warranty documents and information. PERMIT#_�I — 2� 1 BUTTE COUNTY DEVELOPMENT SERVICES REVIEWE® FOR CODE COMPLIANCE QAT� 11-1 YOUR UNIRAC DISTRIBUTOR SOLIGENT Soligent www.soligent.net J www.soligent.net ®©®1411 Broadway Boulevard NE new U N I RAC Albuquerque NM 871oz-1545 USA e 0-1.,"MckPY'g) Installation Guide 703: QMCS SolarMount-I Mount v 2.0 This product is Intended to flash Into new or existing asphalt or wood shingle roof systems with a maximum shingle exposure of 51/2': Quick Mount PV Is an all -in -one waterproof flashing and mount to anchor SolarMount-ITM systems to a new or existing asphalt or wood shingle roof. It is made In the USA of all aluminum and includes stainless steel hardware. It Installs seamlessly and saves labor by not needing to cut away any roofing. Quick Mount PV will also out -live galvanized 2 to 1, and is a better low -profile mount. 1 "'U N 10®® I RAC A HILTI GROUP COMPANY Unirac welcomes input concerning the accuracy and user-friendliness of this publication. Please write to publications@uniraecom. UNI RAC Quick Mount WInstallation Guide for: QMCS SolarMount-I Mount Table I. Lag pull-out (withdrawal) capacities (lbs) in typical roof lumber (ASD) Sources. American Wood Council, NDS 2005, Table I I.2A,11.3.2A Notes: (1)Thread must be embedded in the side grain of a rafter or other structural member integral with the building structure. (2) Lag bolts must be located in the middle third of the structural member. (3) These values are not valid for wet service. (4) This table does not include shear capacities. If necessary, contact a local engineer to specify lag bolt size with regard to shear forces. (5) Install lag bolts with head and washer flush to surface (no gap). Do not over -torque. (6)Withdrawal design values for lag screw connections shall be multiplied by applicable adjustment factors if necessary. See Table 10.3.1 in the American Wood Council NDS forWood Construction. *Use flat washers with lag screws. Flat washers are not necessary with conceolor screws. PERMIT # �« 4�_' 1 3 P.e. BUTTE COUNTY DEVELOPMENT SERV_ICES 2 REVIEWED FOR CODE COMPLIA CE AATLL�O�_ _---- - - BY Specific gravity Lag screw specifications %6- shOA* per inch thread depth Douglas Fir, Larch 0.50 266 Douglas Fir, South 0.46 235 Engelmann Spruce, Lodgepole Pine (MSR 1650 f & higher) 0.46 235 Hem, Fir, Redwood (close grain) 0.43 212 Hem, Fir (North) 0.46 235 T Southern Pine 0.55 307 T Spruce, Pine, Fir 0.42 205 Thread Spruce, Pine, Fir depth (E of 2 million psi and higher grades of MSR and MEL) 0.50 266 Sources. American Wood Council, NDS 2005, Table I I.2A,11.3.2A Notes: (1)Thread must be embedded in the side grain of a rafter or other structural member integral with the building structure. (2) Lag bolts must be located in the middle third of the structural member. (3) These values are not valid for wet service. (4) This table does not include shear capacities. If necessary, contact a local engineer to specify lag bolt size with regard to shear forces. (5) Install lag bolts with head and washer flush to surface (no gap). Do not over -torque. (6)Withdrawal design values for lag screw connections shall be multiplied by applicable adjustment factors if necessary. See Table 10.3.1 in the American Wood Council NDS forWood Construction. *Use flat washers with lag screws. Flat washers are not necessary with conceolor screws. PERMIT # �« 4�_' 1 3 P.e. BUTTE COUNTY DEVELOPMENT SERV_ICES 2 REVIEWED FOR CODE COMPLIA CE AATLL�O�_ _---- - - BY Quick Mount PV Installation Guide for: QMCS SolarMount-I Mount 8H U N I RAC Tools Needed: measuring tape roofing bar chalk line stud finder caulking gun with roofing sealant drill with 1/4" diameter bit drill with 1/2" deep socket Installation: Using horizontal and vertical chalk lines, align holes for placement of each Quick Mount QMCS to rafter. DRILL PILOT HOLE 1. Using drill with K" long bit, drill pilot hole through roof and rafter, taking care to drill square to the roof. * Do not use the flashing as a drill guide 5. LIFT SHINGLE Lift composition roof shingle with roofing bar, just above placement of Quick Mount QMCS. Clean off any sawdust or debris, then, using caulking gun with roofing sealant, squeeze a dab of roofing sealant that is compatible with the roof type into the hole. SLIDE QUICK MOUNT QMCS INTO PLACE Lift comp shingle and slide Quick Mount QMCS into place. PERMIT# � 21(4 — 2 �51_3 BUTT COUNTY DEVELOPMENT SERVICES "" REVIEWED FOR s CODE COMPLIANCE DATE tTl BY ::' U N I RAC^ Quick Mount PV Installation Guidefor. QMCS SoiarMount-I Mount . SSEMBLEANDATTACH LAG BOLT ATTACHMENT Assemble lag bolt with sealing washer, I -Flange Connection, and EPDM rubber washer as shown in the picture. Use drill with A" deep socket to tighten flashing into place. 10 year limited Product Warranty, 5 year limited Finish Warranty Warranty. Quick Mount PV, warrants to the of related items, such as PV modules and racking, original purchaser ("Purchaser') of product(s) that it manufactures ("Product') at the original may provide written warranties of their own. Quick Mount PVs limited Warranty covers only installation site that the Product shall be free from defects in material and workmanship its Product, and not any related items. for a period of ten (10) years, except for the Exclusion of Warranties. EXCEPT FOR anodized finish, which finish shall free from THE WARRANTY STATED ABOVE, QUICK visible peeling, cracking ochalking under MOUNT PV MAKES NO WARRANTIES AS TO normal atmospheric conditionss for a period of THE PRODUCT,WHETHER EXPRESS, IMPLIED five (5) years, from the earlier of I) the date OR STATUTORY INCLUDING IMPLIED the installation of the Product is completed, or WARRANTIES OF MERCHANTABILITY OR 2) 30 days after the purchase of the Product FITNESS FORA PARTICULAR PURPOSE. by the original Purchaser ("Finish Warranty'). The Finish Warranty does not apply to any Limitation of Liability. UNDER NO CIRCUMSTANCES SHALL QUICK MOUNT foreign residue deposited on the finish. All Installations in corrosive atmospheric conditions PV BE LIABLE TO PURCHASER OR ANY OTHER PARTY FOR ANY REPROCUREMENT (including without limitation, chemical fumes, salt water and wind-blown sand) are excluded. COSTS, LOST REVENUE OR PROFITS OR The Finish Warranty is VOID if the practices FOR ANY OTHER SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING specified by AAMA 609 & 610-02 — "Cleaning and Maintenance for Architecturally Finished OUT OF OR RELATED TO THE USE OF THE Aluminum" (www.aamanet.org) are not followed PRODUCT, EVEN IF QUICK MOUNT PV HAS BEEN INFORMED OF SUCH POTENTIAL by Purchaser. This Warranty does not cover damage to the Product that occurs during its LOSS OR DAMAGE. shipment, storage, or installation. This Warranty Indemnification. Purchaser shall defend, shall be VOID if installation of the Product is not indemnify and hold harmless Quick Mount performed in accordance with Quick Mount PVs PV and its Related Persons (as defined below) written installation Instructions,or ifthe Product (each, an "Indemnified Party'), with counsel has been modified, repaired, or reworked in a manner not previously authorized by Quick reasonably acceptable to the Indemnified Party, from and against any and all Claims (as defined Mount PV IN WRITING, or if the Product is below) which may be suffered or incurred by installed in an environment for which It was not the Indemnified Party or imposed or asserted designed. lfwithin the specified Warranty periods against the Indemnified Party. (a) resulting from the Product shall be reasonably proven to be any cause on or about the premises where any defective, then Quick Mount PV shall repair or Product is installed; (b) resulting from the use replace the defective Product or any part thereof, of the Product; (c) arising out of any actual or in Quick Mount PVs sole discretion. Such repair threatened damage to property, or Injuries to or replacement shall completely satisfy and or death of persons for any reason, including discharge all of Quick Mount PV's liability with but not limited to, product performance or respect to this limited Warranty and shall be malfunction, negligence, or improper installation. the Purchasers sole and exclusive remedy. Any "Claims" shall mean any and all claims, actions, repair or replacement of the Product under this demands, proceedings, losses, damages, liabilities, Warranty shall be warranted as provided herein losses, costs and expenses, including attorneys', only for the remaining term of this Warranty as investigators' and consulting fees, court costs and provided for the original Product Manufacturers litigation expenses;"Related Person" shall mean any member, partner, principal, officer, director, shareholder, employee, agent, contractor, consultant, representative, affiliate, assign, successor -in -interest of a specked Party, or any other person that has obtained or hereafter obtains rights or interests from such party. This Warranty constitutes the entire integrated agreement between Quick Mount PV and Purchaser concerning the Product warranties and supersedes all prior agreements and discussions and the terms or any purchaser orders, order acknowledgements or similar documents. No agreement or understanding in any way purporting to modify this Warranty, oral or written, shall be binding on Quick Mount PV unless made in writing and signed by its authorized representative. This Warranty and the parties' rights herein are exclusively governed by and construed In accordance with the laws of the State of California, United states of America, without regard to the laws of any other state or country. The State and federal courts located in Contra Costa County, California shall be the exclusive venue for any legal action relating to this Warranty and Purchaser hereby agrees to the jurisdiction of such courts. All claims made under this warranty must be submitted to Quick Mount PV in writing to the address below within 30 days after Purchaser's discovery the subject defect or problem or the warranty claim will be barred. Quick Mount PV 936 Detroit Ave, Suite D Concord, CA 94518 Phone 925-687-6686 Fax 925-687-6689 www.quickmountpv.com M U N 1 RAC I�'it1i;� 1411 Broadway Boulevard NBC Albuquerque Yr1112-1--�T 4 A HILTI GROUP COMPANY BUl �4 t GOUN IY DEVELOPMENTSERVICES REVIEWED FOR CODE COMPLIANCE DATE l I A U By'i i' 1 STRUCTURAL ENGINEERS January 4, 2016 UniRac 1411 Broadway Boulevard NE Albuquerque, New Mexico 87102-1545 TEL: (505) 242-6411 FAX: (505) 242-6412 Attn.: Engineering Department, Re: Engineering Certification for UniRac's PUB I6JAN05 edition of the "SolarMount Design & Engineering Guide" PZSE, Inc. -Structural Engineers has reviewed UniRac's "SolarMount Design & Engineering Guide" published January 05, 2016 and specifically the enhancements of the SolarMount Flush -to -Roof System, Pressure Lookup Tables, and Downward & Upward Span Length Tables. This certification excludes connections to building structures and the effects on building structure components. All information, data and analysis contained within the Design & Engineering Guide are based on, and comply with the following: 1. 2012 International Building Code, by International Code Council, Inc., 2012 2. 2013 California Building Code, by California Building Standards Commission, 2013 3. ASCE/SEI 7-10 Minimum Design Loads for Buildings and other Structures, by ASCE, 2013 4. 2010 Aluminum Design Manual, by The Aluminum Association, 2010 This letter certifies that the structural calculations contained within UniRac's "SolarMount Design & Engineering Guide" are in compliance with the above Codes. If you have any questions on the above, do not hesitate to call. Prepared By: PZSE, Inc. - Structural Engineers Roseville, CA PERMIT# 1�!21( ,2, BUTTE COUNTY DEVELOPMENT SERVICES 81 50 Sierra College Boulevard, Suite 150 • Roseville, CA 95661 ww 916.961.3460 P • 916.961.3965 • w.pzse.com BREVIEWED FOR CO COMPLIANCE DATE BY