Loading...
HomeMy WebLinkAboutB16-2491 000-000-000Eng. NumberbAA687669-C2_01 October 7 2016 Page 1 of 2 AMERICAN TOWERO CORPO RATIO N Structural Evaluation ATC Site Number & Name 8359, Hwy99-Anita, CA BUTTE Carrier Site Number & Name CVL00239, CANA COUNTY Site Location 15082 Hamilton Nord - Cana Highway NOV 09 2016 Chico, CA 95973-9489, Butte County 39.85250278 N / -121.95258889 W DEVELOPMENT Tower Description 185 ft Self Supported Tower 'SERVIc Its Basic Wind Speed Code 85 mph (3 -Second Gust, Vd) / 110 mph (3 -Second Gust, V„ n) ANSI/TIA-222-G / 2012 IBC / 2013 California Building Code Existing and Reserved Equipment Elevation' (ft) Qty Antenna Mount Type Lines . Carrier Mount RAD 185.0 182.0 6 Ericsson AIR 21, 1.3 M, 62A 64P Sector Frame (12)15/8" Coax (1)11/4 Hybriflex T -Mobile 178.0 178.0 1 Decibel VHP4-180A Leg (1)1/2" Coax 170.0 169.0 3 Antel BXA-70063/4CF Sector Frame (12)15/8" Coax Verizon 6 Powerwave 7130.16 163.0 165.0 1 4' Grid Dish Leg (1)1/2" Coax - 161.0 1 THP Dish 155.0 155.0 3 Samsung 1.9 GHz RRH Sector FRame (3)1.26" (32mm) Hybrid Fanout Cable (Type 11) Sprint Nextel Samsung 80OMHz RRH 2nd Gen w/ 3 filter 1 RFS APXV9ERR18-C-A20 2 KMW ETA -TS -70 -15 -62 -18 -ill -RD 148.0 148.0 1 Adtran Tracer 6320 Leg (1)1/2" Coax 1 4' Dish w/ Radome 140.0 140.0 6 ADC AWC-DTMA-AWS/PCS Sector Frame (6)15/8" Coax (1)1/2" Coax (1) 3/8" Coax Metro PCS 1 15" x 15" Panel 2 Allgon 7220.42 1 CeIIMax CMA-B/6521/EO-6 1 Powerwave 7221 / M-1900-30-231 2 CeIIMax CMA -B/3324 125.0 125.0 6 Kathrein 86010025 Sector Frame (24)15/8" Coax (1) 3/8" (0.38") RET Control Cable (1) 0.41" LMR -400 AT&T Mobility 9 AndrewATM200-001 3 Ericsson KRY 112 89/4 6 Ericsson KRY 112 71/2 1 Raycap DC6-48-60-18-8F 3 Ericsson RRUS-11 1 Powerwave 7130.16.05.00 / A-800-95- 141-0-N 3 Kathrein 80010765 3 Andrew TBXLHB-6565A-VTM 115.0 115.0 1 Andrew HP6-107/H Le g (1) EW90 Verizon 104.0 104.0 1 4' Std. Dish (1) 0.41" LMR -400 AT&T Mobility 96.0 96.0 1 Andrew HP6-107/H (1) EW90 Verizon 95.0 95.0 1 Andrew HP4-105 PERMIT# BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR CnnF COMPLIANCE .., DATE (I I ` -% I I ( BY �1. - - -- - ATC Tower Services, Inc. 3500 Regency Parkway, Suite 100 -Cary, NC 27518-919-468-0112 Office - 919-466-5414 Fax - www.americantower.com p5 t� AMERICAN TOWER° CO RP - O R'AT 1.6 N' Equipment to be Removed - Eng. Number OAA687669_C2_01 October 7 2016 Page 2 of 2 Elevation' (ft) Qty Antenna Mount Type Lines Carrier Mount RAD 5 Kathrein 742-264/AP14/17- (2) 0.39" Fiber Trunk 1 Quintel QS6656-3 3 880/1940/065D/ADT/XXP (2) 0.78" 8 AWG 6 125.0 125.0 - AT&T Mobility 4 Powerwave 7130.16.05.00 / A-800-95- 125.0 125.0 2 (1) 2" conduit _ 141-0-N (1) 3/8" (038") RET AT&T Mobility Proposed Equipment Elevation' (ft) Qty Antenna Mount Type Lines Carrier Mount RAD 5 Ericsson RRUS-32 (2) 0.39" Fiber Trunk 1 Quintel QS6656-3 (2) 0.78" 8 AWG 6 (2) 0.39" Cable 4 CCI HBSA-M65R-KU-H6 125.0 125.0 Sector Frame (1) 2" conduit _ (1) 3/8" (038") RET AT&T Mobility 1 Raycap DC6-48-60-18-8F Control Cable (1) 0.41" LMR -400 104.0 104.0 1 Ericsson Mini -Link TN R4 Leg - mount elevation Is oetinea as neignt above bottom of steel structure to bottom of mount, RAD elevation is defined as center of antenna above grade level (AGL). Install proposed coax alongside existing At&t Mobility coax. The existing and proposed loads listed in the tables above are compared to the tower's current design capacity or previous structural analysis. The tower should be re-evaluated as future loads are added or if actual loads are found different from those listed in the tables. The subject tower and foundation are adequate to support the above stated loads in conformance with specified requirements. J 0 GAR A m rn U-169570 "� sT clv�� �TFOF CA0 JDB/EDR ATC Tower Services, Inc. 3500 Regency Parkway, Suite 100 - Cary, NC 27518 — 919-468-0112 Office — 919-466-5414 Fax - www.americantower.com