HomeMy WebLinkAboutB16-2575 047-460-028BUTTE COUNTY .AREA
DEPARTMENT,OF DEVELOPMENT SERVICES 4 "
INSPE TION CARD MUST BE ON JOB SITE
24 Hour Inspection Line (IVR) :530.538.4365 (Cut off time for inspections is Spm)
'HENT SERVICES
Development Services cannot guarantee inspections on the date requested
*.. Office: 530.538.7601 Fax: D30
tNo: B16-2575 Issued: 11/21/2016
047-460-028
;s: 15 PARSLEY LN, CH:ICO
THOMPSON SERENA L
Type: SOLAR ROOF -RES
)tion: • Installation of res. roof mow-Ited solar
ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING
InsvectionType
IVR INSP DATE
Setbacks
131
Foundations / Footings.
111.'
' Pier/Column Footings
122,
Eufer Ground
216
Masonry Grout
120
Setbacks
131
Do Not Pour Concrete Until Above are -Sign d
Pre -Slab
124
Gas Test Underground/floor
404
Gas Piping Underground/floor
403
Underfloor Framing
149
Underfloor Ducts
319
Shear Transfer
136
Under Floor Plumbing
412
Under Slab Plumbing
411
Blockin nder inin
612
Tiedow n/Soft- Set System
611
Do Not Install Floor Sheathing
or Slab Until Above Signed
Shearwall/B.W.P.-Interior
134,
Shearwall/B.W.P.-Exterior
135
Roof Nail/Drag Trusses
129'
Manometer Test ''
605
Do Not Install Siding/Stucco or Roofing Until Above Signed
Rough Framing 1
153
Rough Plumbing
406
Rough Mechanical
316
Rough Electrical
208
4 -Way Rough Framing
128
Gas Piping House
403 .
Gas Test House
404
Shower Pan/Tub Test
408'
Do Not Insulate Until Above Si ned
Permit Final
802 l �[
Electrical Final
803
Mechanical Final
809
Plumbing Final
813.
Fire Sprinkler Test or Final
702
Swimming
7771
ilillikm
Inspection Type
IVR INSP DATE
T -Bar Ceiling
145
Stucco Lath
142
Swimming
Pools
Setbacks
131
Pool Plumbing Test
504
Gas Test
404
Pre-Gunite
506
Pre -Deck
505
Pool Fencing/Alarms/Barriers
503
Pre -Plaster
507
Manufactured Homes -
Setbacks
131
Blockin nder inin
612
Tiedow n/Soft- Set System
611
Permanent Foundation System
61.3
Underground Electric
218
Sewer
407
Underground Water
417
Manometer Test ''
605
Continuity Test
602
Skirtin /Ste s/Landin s
610
Coach Info
Manufactures Name:
Date of Manufacture:
Model Name/Number:
Serial Numbers:
Length x Width:
Insignia:
Public Works Final 538.7681
Fire De artment/CDF 3 538.6226
Env. Health Final ' 538.7281
Sewer District Final
**PROJECT FINAL'
.I -rrojecr rural is a i-ernncate Of Uccupancy Tor Ircesiaennalvnip)
PERNIITS BECOME NULL AND VOID 1 1 EAR FROM THE DATE OF ISSUANCE. IF WORK HAS COIi'IMENCED, YOU MAY PAY FOR A I YEAR
RENEWAL 30 DAYS PRIOR TO EXPIRATION
b
I
Carbon monoxide alarms required by Sections R315.1 and R315.2 shall be installed in the
following locations:
1. Outside of each separate dweiling,unit sleeping area in the immediate vicinity of the
bedroom(s).
2. On every level of a dwelling unit including basements. ,
R315.1.5 Multiple -purpose alarins: Carbon monoxide alarms combined with smoke alarms
shall comply with Section R315, all applicable standards, and requirements for listing and
approval by the Office of the State Fire Marshal, for smoke alarms.
Butte County's Interpretation of 2013 CRC, Sections 314 & 315 for
Smoke Alarms & Carbon Monoxide Alarms:
Where alterations, repairs or additions exceeding $1,000 in valuation; existing dwellings shall be
retrofitted with smoke alarms and those that have attached garages or fuel -burning appliances shall have
carbon monoxide alarms installed. Existing smoke alarms can be replaced with dual function alarms for
Smoke and Carbon Monoxide and in most cases will comply with the aforementioned code requirements
for Carbon Monoxide Alarms.
DECLARATION OF INSTALLATION UNDER THE PENALTY OF PERJURY
As Owner/Contractor, Uwe affirm and declare under the penalty of perjury, under the laws
of the State of California, by our signatures below as Owner/Contractor, that I/we will
comply prior to final inspection with Items A & B as specified herein:
A. Both Owner/Contractor have read and clearly understand the aforementioned 2010
California Residential Code (CRC) Carbon Monoxide Alarm requirements.
B. Both Owner/Contractor are responsible for installing Carbon Monoxide Alarms prior to
final'inspection as per the aforementioned building code and maintaining such
in Smoke Alarms will, also be.installed prior to final. inspection as.per the 2010 .
CRC.
Smoke and Carbon. Monoxide alarms are now installed in the following locations:
In LWVt1,1G S&S, -6U f;O t
A' f-�e* S RC1 ,ol:% OcouA A Nw wr,5toe
Owner's name (print):
nrn WLx 5 Anl1) "6 TX'*z—L hTTt�S
.���it/ tU �/l .fin ��/��� .
Owner's signature:_
Contractor's name.i
Contractor's signatt
CSLB License:
rlatc• l v /�S // -7
ProjectAddress:CG1C ULA Ln, CJ01 Q Permit #`,&(Q-015
Page 2 of 2
/°rte,.
Butte County Department of Development Services FAM l
PERMIT CENTER
7 County Center Drive, Oroville, CA 95965 DBI -01
" °' • ""' '+ Main Phone (530) 538-7601 Fax (530) 538-7785
www.buttecounty.net/dds
Declaration of Installation
for Smoke Alarms and Carbon Monoxide Alarms
The newly adopted 2013 California Residential Code requires the installation of Carbon
Monoxide Detectors in dwelling units and in sleeping units within which fuel -burning appliances
are installed and in dwelling units that have attached garages. The policy for Carbon Monoxide
Alarms, in Butte County states: "Any permit obtained in which the value of work exceeds $1000
associated with a Residential Group R Dwelling Unit or Sleeping Unit shall conform to the
following 2013 California Residential Code requirements for Smoke and Carbon Monoxide
Alarms (Section R314 & R315)."
2013 California Residential Code requirements for Carbon Monoxide Alarms:
R315.1 New construction: An approved carbon monoxide alarm shall be installed in dwelling
units and in sleeping units within which fuel -burning appliances are installed and in dwelling
units that have attached garages.
R315.1.2 Power supply: For new construction required carbon monoxide alarms shall receive
their primary power from the building wiring where such wiring is served from a commercial
.source and shall be equipped with a battery back-up. Alarm wiring shall be directly connected to
the permanent building wiring without a disconnecting switch other than as required for over -
current protection.
EXC¢prlOI1S:
r
1. In dwelling units where there is no commercial power supply the carbon monoxide alarm may be solely
battery operated.
2. In existing dwelling units a carbon monoxide alarm is permitted to be solely battery operated where
repairs or alterations do not result in the removal of wall and ceiling finishes
or there is no access by means of attic, basement or crawl space.
R315.1.3 Interconnection. Where more than one carbon monoxide alarm is required to be
installed within the dwelling unit or within a sleeping unit the alarm shall be interconnected in a
manner that activation of one alarm shall activate all of the alarms in the individual unit.
Exception:
1. Interconnection is not required in existing dwelling units where repairs do not result in the
removal of wall and ceiling finishes, there is no access by means of attic basement or crawl
space, and no Previous method for interconnection existed
R315.2 Where required in existing dwellings: Where a permit is required for alterations,
repairs or additions exceeding one thousand dollars ($1,000), existing dwellings or sleeping
units that have attached garages or fuel -burning appliances shall be provided with a carbon
monoxide alarm in accordance with Section R315.1. Carbon monoxide alarms shall only be
required in the specific dwelling unit or sleeping unit for which the permit was obtained.
R315.2.6 Alarm requirements: No person shall install, market, distribute, offer for sale or sell
='any carbon monoxide device in the'State of,California.unless.the device'and instructions have
been approved and listed by the State Fire Marshal.
Paget of 2
:o
vivinTIvIsdar- PV SOLAR SYSTEM SPECIFICATIONS:
z a
SYSTEM SIZE - 9.975KW DC/ 8.050KW AC
w�
o N
THOMPSON RESIDENCE MODULE TYPE & AMOUNT - (35) JINKO SOLAR JKM285M-60B
wm
MODULE DIMENSIONS - (UW/H) 64.97in/ 39.06in/ 1.57in
z �oZ
;15' PARSLEY LN
INVERTER - (35) ENPHASE IQ6-60-2-US
voo
CH I CO, CA 95973 •INVERTER(S) USED IN THIS DESIGN IS/ARE COMPLIANT WITH CEC 201.690.12 (RAPID SHUTDOWN). SEE MANUFACTURER DATA SHEET.
2 . a
INTERCONNECTION METHOD - LOADBREAKER
o
GOVERNING CODES SHEET'INDEX`
ALL WORK SHALL CONFORM TO THE FOLLOWING CODES
�tJ
• 2016 CALIFORNIA BUILDING CODE PV 0.0 - COVER ,SHEET
• 2016 CALIFORNIA ENERGY CODE PV 1.0 - SITE PLAN
• 2016 CALIFORNIA ELECTRICAL CODE PV 2.0 -'MOUNTING DETAIL
"
2016 CALIFORNIA FIRE CODE PV 3.0 - FRAMING DETAIL
• 2016 CALIFORNIA GREEN CODE E 1.0 - 3 -LINE DIAGRAM
c
"
2016 CALIFORNIA MECHANICAL CODE E 2.0 - NOTES
°` m
• 2016 CALIFORNIA PLUMBING CODE E 3.0 - WARNING LABELS
o®/ v
• 2016 CALIFORNIA RESIDENTIAL CODE E 4.0 - WARNING LABELS -CONT.
• ANY OTHER LOCAL AMENDMENTS E 5.0 - ELECTRICAL PHOTOS
E 5.1 - ELECTRICAL PHOTOS CONT.
'
pO
5m �
y K N
f W
2
*
W W m
K
Z Z Q
•
-
SHEET
-
NAME:
W w
-
>w
"
NOTES:
• ,
A PHOTOVOLTAIC MOUNTING RACK INSPECTION MAY BE REQUIRED PRIOR TO PANEL INSTALLATIONS
(,) (n
_
ANY MODIFICATIONS TO THE EXISTING ROOF AND/OR PLUMBING DRAIN, WASTE, AND/OR VENTS AR TO COMPLY WITH THE 2016
SHEET
CBC/CPC
NUMBER:
ALL EMT CONDUIT FITTINGS SHALL BE LISTED AS WEATHERPROOF FITTINGS
THE BACKFEED BREAKER SHALL NOT BE MARKED FOR "LINE" AND "LOAD" MARKINGS
61
CONDUIT RUN THROUGH THE ATTIC OR UNDER EAVES DENOTED WITH DASHED LINES ON SITE PLAN -
>
SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED, PURSUANT TO SECTIONS R314 AND R 315 OF THE CRC
d
�' .
®®,�
j
�'mmm*o
to
0
.
oio,.8m
'o—<Dm
o� Kms. o.o x
<m Om
Ziy
po33N
DCjO mvoi `c p�`c u±
D3 ��
>N; --
30 3n 3n i
r ., O— O— O._ .
On On o�.
mN'
1� D�
m0 ym
.�Oy
IcOC T V Win. mZnOm
O y m z y
m
Z N O
(7.
r C r C .r'C
T y m y T-4
f�
qT
po 00
<
00.
"Z
_� yy
Z T ,_ CTO 0
��m.Z zOZ ypz m.0
Z
3
a �.�
N N A y A
p
3y f0
mT
Oz�p ~DO 003
xmxm ov,x zoo'
T-
V1
r
m
mm x0
m9 Zy
1nD
Q
pA
Zo
�p O mmD �py0
-0 Z- °: �Oo
m
O
y
m
A
px
0 0 O n
�0 :3n
0 m
i�
o3g
C C Z X x n m y C
myv, O m Oxny
Z
O
y�ln y�l/7z;0 '� V� V
o
mo
Vol
y�
om pig rS�ZVDjZ
�
° �.8op
p <(fl <'^
O
=� 0
z
o'T °o p + m m
'3
-
o ..
5-9 -1 (.%1 � v V J
(71
• y
xbm o o'g
m < .. ,� p
sC1
2 0 c� (n
N
�m�m
N
15 PARSLEY LN, CHICO,
CA 95973 m
FRONT OF HOUSE_
m
.. , -
4
•
I
ip:i
iral,
I
+
V
C
U)
m
—
— —
— —
w
•
m
W
N
�
,
z
m
D
"
Z
-
z m
mm
SITE
z m
INSTALLER: VIVINT SOLAR -
p
THOMPSONSRESIDENCE
zm
INSTALLER NUMBER: 1.677.404.4129
PV 1.0
y
y
V��O�te ���-
LEY LN
p
PLAN
CHICO, CA 95973
DRAWN BY: JC S: 5319217
Last Modified: 9/612017 -
UTILITY ACCOUNT NUMBER: 42376594174
ui
U
Z
w
e
(/% Zn!
Lu
�mm
ie
WU�
O Ird
<
(/J QUO
c�
G }
O C
j
e>�
o
•� ii
g
< N
D:
N N
Z �
>�
Z
W w
m
3
�� 9
Z Z 0
SHEET
NAME: (/)
Z J
c� Lli
G Q
SHEET
NUMBER:
0
NIq
a
!�r^r
•;:�^9c�i:,, il, COMP SHINGLES, ROCK-IT COUPLING
MID CLAMP
�•"r':'.'%r• � '�'
ROCK IT COUPLING
jROCK-IT
c,{.;+/!,`a, +.:y.'^�w.;�•r �'r MID CLAMP o '
ROCK-IT COUPLING + ^�•,:;T;,,;n� rn,� �„�s: i..+'�,:e;i,;
' MID CLAMP
_- • It `r^.•,-i':•;y4•i ROCK-R COUPLING SHELF
•C:t1 Ss:`• �K. 'yak .+r{r(.
�r.
ROCK-IT
-ROCK-IT SLIDE SHIP LAP
PEDESTAL METAL FLASHING - ROCK•R
- METAL- TIE PLATE 5116'x1 1/2' COUPLING SHELF
• 5I16Sr316' FLASHING ISOMETRIC VIEW HEX FLANGE BOLT _
HEX FLANGE BOLT SIDE VIEW 300 SERIES SS ISOMETRIC VIEW
'300 SERIES SS
_ .COMP SHINGLES - '
(1)y1s•:ain•.
' SS LAG SCREW - ,
TOROUE=1312 FT-LBS. SIDE VIEW
I ROCK-IT MOUNT � z ROCK-IT COUPLING ASSEMBLY
PV Z.O � 'NOT TO SCALE NOT TO SCALE TOP VIEW
• CLAMP+ATTACHMENT CLAMP +ATTACHMENT
� COUPLING PERMITTED COUPLING
CANTILEVER L/! OR LESS CLAMP SPADING
1 i
• =MAX 72' (6' - I I{ -•
COUPLING CLAMP RAFTER MODULE
ROCK-IT SLIDE
.MODULE
METAL MODULE - •
FLASHING � . EPDM BONDED WASHER RAFTER - � ( I � I , �• I' RAFTER
_ FORMS WATERTIGHT SEAL
_ — I = ANDSCAP .AMP SPACING
• APV SYSTEM MOUNTING DETAIL (2)MODULES IN PORTRAIT/LANDSCAPE L=PORTRAIT
PV 2.0 "Of TO �E PV 2.0 rrormwvF CLAMP SPACING
COMP. SHINGLES �
2 1/2 MIN 3• MIN AND 6' MA%SETWEEN TOP OF ROOF AND BOTTOM OF MODULE
• ONE HOLE STEEL STRAP CONDUIT
5/16141/2' - -
' SS LAG SCREW ' 1 -
TOROUE=1312 F7{gg, PV MODULE, TVP. MOUNT O
TO FRAMING OF EXISTING PV 3.0
• '� - ROOF TYPE, PARALLEL CONDUIT MOUNT BRACKET
. 6' MAYlIf3tl OF ROOF
- SECTION VIEW.
FLASHING OR TILE STRAP
3 SECTION' VIEW -
No7 To SCALE 6 PV ARRAY TYP. ELEVATION 7 CONDUIT MOUNTING DETAIL
PV'2.0 Pv z.o roo7msrue Pv z.o -TTG—
ui
U
Z
w
e
(/% Zn!
Lu
�mm
ie
WU�
O Ird
<
(/J QUO
c�
G }
O C
j
e>�
o
•� ii
g
< N
D:
N N
Z �
>�
Z
W w
m
3
�� 9
Z Z 0
SHEET
NAME: (/)
Z J
c� Lli
G Q
SHEET
NUMBER:
0
NIq
a
!�r^r
•;:�^9c�i:,, il, COMP SHINGLES, ROCK-IT COUPLING
MID CLAMP
�•"r':'.'%r• � '�'
ROCK IT COUPLING
jROCK-IT
c,{.;+/!,`a, +.:y.'^�w.;�•r �'r MID CLAMP o '
ROCK-IT COUPLING + ^�•,:;T;,,;n� rn,� �„�s: i..+'�,:e;i,;
' MID CLAMP
_- • It `r^.•,-i':•;y4•i ROCK-R COUPLING SHELF
•C:t1 Ss:`• �K. 'yak .+r{r(.
�r.
ROCK-IT
-ROCK-IT SLIDE SHIP LAP
PEDESTAL METAL FLASHING - ROCK•R
- METAL- TIE PLATE 5116'x1 1/2' COUPLING SHELF
• 5I16Sr316' FLASHING ISOMETRIC VIEW HEX FLANGE BOLT _
HEX FLANGE BOLT SIDE VIEW 300 SERIES SS ISOMETRIC VIEW
'300 SERIES SS
_ .COMP SHINGLES - '
(1)y1s•:ain•.
' SS LAG SCREW - ,
TOROUE=1312 FT-LBS. SIDE VIEW
I ROCK-IT MOUNT � z ROCK-IT COUPLING ASSEMBLY
PV Z.O � 'NOT TO SCALE NOT TO SCALE TOP VIEW
• CLAMP+ATTACHMENT CLAMP +ATTACHMENT
� COUPLING PERMITTED COUPLING
CANTILEVER L/! OR LESS CLAMP SPADING
1 i
• =MAX 72' (6' - I I{ -•
COUPLING CLAMP RAFTER MODULE
ROCK-IT SLIDE
.MODULE
METAL MODULE - •
FLASHING � . EPDM BONDED WASHER RAFTER - � ( I � I , �• I' RAFTER
_ FORMS WATERTIGHT SEAL
_ — I = ANDSCAP .AMP SPACING
• APV SYSTEM MOUNTING DETAIL (2)MODULES IN PORTRAIT/LANDSCAPE L=PORTRAIT
PV 2.0 "Of TO �E PV 2.0 rrormwvF CLAMP SPACING
COMP. SHINGLES �
2 1/2 MIN 3• MIN AND 6' MA%SETWEEN TOP OF ROOF AND BOTTOM OF MODULE
• ONE HOLE STEEL STRAP CONDUIT
5/16141/2' - -
' SS LAG SCREW ' 1 -
TOROUE=1312 F7{gg, PV MODULE, TVP. MOUNT O
TO FRAMING OF EXISTING PV 3.0
• '� - ROOF TYPE, PARALLEL CONDUIT MOUNT BRACKET
. 6' MAYlIf3tl OF ROOF
- SECTION VIEW.
FLASHING OR TILE STRAP
3 SECTION' VIEW -
No7 To SCALE 6 PV ARRAY TYP. ELEVATION 7 CONDUIT MOUNTING DETAIL
PV'2.0 Pv z.o roo7msrue Pv z.o -TTG—
'ROOF SECTION 1
ROOF SECTION 1 FROM PV 1.0
MEMBER SIZE:
TRUSS 2x6 AT 24" O.C.
R
C �mw
O mQ�
az
15'1
O "°
L U
C t
•
P
U)
3' EAVE �. 12.1'
INTERIOR HORIZONTAL DISTANCE
CL
ROOF SECTION 2
ROOF SECTION 2 FROM PV 1.0
MEMBER SIZE:
n
m
TRUSS 2x6 AT 24" O.C.iL
K
N
3
Or 30
};Z�F
U
W W
Z m
•
0
w
6 ¢
WZ
J
• • U z
•
Z Z
U O
SHM NAME:
Z�
-
1
O
_ _ •
LL
SNEEi
NUMBER:
3' EAVE 16' I
PV 3.0
INTERIOR HORIZONTAL DISTANCE ` r
a a
_ m y
c
• o� m
H n
O n
4
• Photovoltaic System
- Conduit Conductor Schedule (ALL CONDUCTORS MUST BE COPPER)
DC System Size (Watts) 9975
Tag If Description
Wire Gauge p of Conductors/Color
Conduit Type
Conduit Size
a
AC System Size (Watts)8050
1 Enphase Engage Cable THWN-2
12 AWG
� 3(1.1, 1.2, G)
N/A -Free Air N/A -Free Air
�
Module/Inverter Count - 35
1 Bare Copper Ground(EGC/GEC)
6 AWG
1 BARE
N/A -Free Air
N/A -Free Air
m
2 THWN - 2
10 AWG
6(31.1 31.2) B/R
EMT
3/4"
Z
M W
r^n
' -
2 THWN-2 -Ground
8 AWG
1(GRN)
EMT
3/4"
N g
o
-
3THWN-2
8AWG
3(1L11L2IN) 8/R/W
EMT
3/4"
o a
'
3 THWN-2 - Ground
8 AWG
1(GRN)
EMT
3/4"
n N
E
0
" u
a
f` OB
cq 11.1
�.
CID
a
•
to
m
•
m
N
pp O
_
f` OB
cq 11.1
a
Z
m
Rapid Shutdown
>
7 m
'
Disconnect, SquareD
Point of Interconnection, Supply Side:
>
Z
-"
DU222RB, 240W60A
705.12(A)
w
w w
w
'
-
XE
N
PV Circuit3: 10
1
2
t
Existing 240V/200A
_
SHEET
Modules/
Inverter:.Enphase'
p A.
Service Panel, Single
Parallel
... r:j
-.106-60-2-US
IVf
Phase;Ma'n houseload
NAME:
- -
.-
on 200A dl sconnect
PVCircuit 2: 11
t0
Modules
Parallel
O00i
k
-
993
SA
ril D
s
;.:.:
3
SHEET
'PVCircuit 1:14
1 ner an voy-
140V Conti nuous.
NUMBER:
Modules /
1
protecdon max 60A breaker on combiner ouput;
Parallel
wlth lO KAIC circuit breakers -
NEMA
4 Junction
Box wl th
lrreversi ble
visa c a e niW
Mi ni mum GEC sl ze4
Ground Splice(1YP)
A/C 01 sconnect
AWG copper ..
La
SOLAR MODULE
Enphase I.._. 146 -60 -2 -US
MICRO-INVERTERAT
EACH MODULE, ATTACHED
WITH ECOLIBRIUM SOLAR
HARDWARE
#6 BARE CU GROUND
(ATTACHED TO FIRST MODULE IN
ARRAY). BALANCE OF ARRAY _
GROUNDING CONNECTIONS
MADE THROUGH ARRAY
HARDWARE
MICROINVERTER CONNECTION
TO ENGAGE TRUNK CABLE . -
Inverter Make/Model 10.6 -60 -2 -US
Max. Dc Volt Rating
48
- Volts
Max. Power at 40 C
230
Watts
Nominal AC Voltage -
240
Volts
Max. At Current
0.96
Amps
Max. OCPD Rating
20
.Amps
Max. Panels/Circuit
16
15
Short Circuit Current
15
Amps
• Other Notes
.PV Module Rating @'STC
33.6
Module Make/Model **
1KM285M-60B
1 240
Max. Power -Point Current (Imp)
8.9
Amps
Max. Power -Point Voltage (Vm)
- 32
Volts
.Open -Circuit Voltage (Voc) .
38.7
Volts
Short -Circuit Current (Isc)
9.65
Amps
Max. Series Fuse (OCPD)
15
Amps
Nom. Max. Power at STC (Pmax)
285
Watts
Max. System Voltage -
1000 V DC (UL)
Voc Temperature Coefficient
-0.29
%/C
AC Output Current According to art. 690.8(8)(1)
33.6
Amps
Nominal AC Voltage
1 240
1 Volts
THIS PANEL IS FED BY MULTIPLE SOURCES (UTILITY AND SOLAR)
Rooftop conductor ampacities designed in compliance with art.
690.8; Tables 310.15(8)(2)(a), 310.15(B)(3)(a), 310.15(B)(3)(c),
310.15(B)(16), Chapter 9 Table 4, 5, & 9. Loacation specific
temperature obtained from ASHRAE 2013 data tables.
ASHRAE2013-
Highest Monthly 2% D.B. Design Temp.: 38.7 `C
Lowest Min. Mean Extreme D.B.: -3.8 °C
• Designed according to, and all code citations are relevant to, the CEC 2016.
• Utility Service Provided by PGE
• No battery back-ups are tied to the designed inverter(s).
Inverters) used in.this design is/are compliant with 690.12 (Rapid Shutdown). See manufacturer data sheet
• Array grounding and bonding designed in compliance with 690.47(C)(3).
Conductor Calculations I a
n
- Wire gauge calculated from art. code 310.15(8)(16) with ambient temperature calculations from
art. 310.15(2)(a). J
For "On Roof' conductors we use the 90°C column ampacity, 0.5"-3.5" off -the -roof temperature
adjustment from 310.15(B)(3)(c), and raceway fill adjustments from 310.15(8)(16). S o
For "Off Roof' conductors we use the 75`C column ampacity, or the 90°C column ampacity with o
O
the relevant ambient temperature and raceway fill adjustments, whichever is less. E L
The rating of the conductor after adjustments MUST be greater than, or equal to, the continuous t Q
duty uprated output current. ~
Calculation Example - Wire Rating (90°C) x Ambient Temperature Adjustment x Conduit Fill
Adjustment >= Continuous Duty Output Current
(On Roof, Tag 2): 10 gauge wire rated for 40 A, 40 A x 0.65 x 0.8 (6 Conductors) = 20.8 A >_
16.8 A
(Off Roof, Tag 3): 8 gauge wire rated for 50 A, 50 A >= 42 A
L
O
N
4112
C
OCPD Calculations
m
ry
$ s
Breakers sized according to continuous duty output current. PV circuit nominal current based off #
a
a L,
of modules per Circuit X (1.25(art. 210.19(A)(1)(a)j) X (0.96 Max AC current per micro -inverter)
o
.+ u
Circuit #1 = 14 modules, Output Current w/ continuous duty = 16.8 < 20A Breaker
z
W
Circuit #2 = 11 modules, Output Current w/ continuous duty = 13.2 < 20A Breaker
m
Circuit #3 = 10 modules, Output Current w/ continuous duty = 12 < 20A Breaker
m
system output current w/ continuous duty = 42 < 45A (System OCPD)
�
�
NUMBER:
C4
W
` .Inverter Grounded Systems Per 690:5 C
Main Service Panel Signage
r
-.-
_
a (Installed on the Face of the Service Meter)
f
+
♦,
v m
n
-
-ELECTRICAL SHOCK.•D
Per 690.54, 690.56(8), & 705.10'"
._
'
rIF A GROUND FAULT IS INDICATED,
Note: Rbofline placard not needed unless PV disconnect is not at the
c S
•NORMALLY GROUNDED CONDUCTORS
'• same location as the main service
-
n v d
u • r .
MAY BE UNGROUNDED AND ENERGIZED
CAUTIONSOLAR ELECTRICAL SYSTEM CONNECTED
E
o
a
`
r u
B7 +
- Combiner Boxes, J -Boxes; Disconnects, Devices, &
-
- ,- Inverters In Un -Grounded Systems Per 690.35(F) (String .� ,
• • - • - . • . • •
-
'[ .
systems)e
• • • . • •
o
'
WARNING
•
.,.
• sELECTRICAL SHOCK• .
I
.n +. F r
THE DC CONDUCTORS OF THIS
PHOTOVOLTAIC SYSTEM ARE UNGROUNDED
'7
L_
AND MAY BE ENERGIZED
'
' ' •
_ r Conduit, Racewa s, and 1 -Boxes Labeled Eve 10'
.,
WARNING: PHOTOVOLTAIC POWER SOURCE
r
AC Disconnect and Any Load Centers (Combiner Panel) !
> - -
„,�
•n+
.,
" Perb90.17(E) &-705.12 _
-r`
POWERWARNING: DUAL SOURCE
. •PHOTOVOLTAIC-
�'
-
-
•
o+
'PHOTOVOLTAIC
RATE• •CURRENT:
Cr
'
- �.
.•
m: a
AC DISCONNECT
RATED AC OUTPUT •
�•
f
-
r
t.
NOM. OPERATING AC VOLTAGE:• r
, - DC Disconnect Per 690,1.7 ;� _
- _ �• ti -
- .. ,..
WARNING
%
ELECTRICAL SHOCK HAZARD
DO NOT TOUCH TERMINALS. TERMINALS ON
WARNING
BOTH THE LINE AND LOAD SIDES MAY BE
ELECTRICAL SHOCK HAZARD
ENERGIZED IN THE OPEN POSITION
DO NOT TOUCH TERMINALS. TERMINALS ON
BOTH THE LINE AND LOAD SIDES MAY BE
Z
ENERGIZED IN THE OPEN POSITION
t
'q
' Inverter Output Connection (Solar Breaker) at -
r^'
'r.
r
A, .Main Service Panel Pei 705.12
Jr
.' _ _
��' _ - - • • {
_
• ._, kb -.,
z m
i
r
WARNINGt
. .. .. ;
.i • a
.w
x t.
>
INVERTER OUTPUT CONNECTION
z
DO NOT RELOCATE THIS
w w
. ♦
Rapid Shutdown Per 690.56(C).
-� Rapid Shutdown Disconnect Per 690.12(5) Installed On AC Disconnect
- -
VI
z-
-
..PHOTOVOLTAIC SYSTEM EQUIPPED
• . • • • •
r
..
SHEET .. r
- ' rWITH RAPID . •
_.
.• - , -
r
'
' . , ..
_
NAME:
•
..,
".
'i.
„
SHEET
_. - ....
. .
.,
. t
• •
NUMBER:
ALL STICKERS DESCRIBED HERIN SHALL BE MADE OF WEATHERPROOF
ADHESIVE, THEY SHALL BE REFLECTIVE, THEY SHALL CONTAIN NO,
SMALLER THAN 3/8• WHITE ARIAL FONT TEXT AND HAVE A RED BACKGROUND UNLESS OTHERWISE DEPICTED OR DESCRIBED.
,.
_•
.,
.,
r Wyk=
�
- 1 4 -
•f 4
, .' .. .�
s
'
y
CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED A WARNING: DUAL POWER SOURCE (� WARNING
1 9 12
WARNING
a
Property of Vivint Solar SECOND
-
SOURCE IS A PHOTOVOLTAIC SYSTEM ELECTRICAL SHOCK HAZARD
-
ELECTRICAL SHOCK HAZARD
a
MAIN BREAKER DE -RATED TO ••' DUE TOSOLAR
RATED AC OUTPUT CURRENT: '•• A IF A GROUND FAULT IS INDICATED,
THE OC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE
Z ^
CIRCUITS
2. ***AMPS
NOM. OPERATING AC VOLTAGE: ••' V NORMALLY GROUNDED CONDUCTORS
UNGROUNDED AND MAY BE ENERGIZED
M
W N
O
m
MAX OF PV SOURCE ALLOWED
Property of Vivint Solar MAY BE UNGROUNDED AND ENERGIZED
Property of Vivint Solar
s�
DO NOT INCREASE MAIN BREAKER RATING WARNING: PHOTOVOLTAIC POWErty of Vivint Solar
R SOURCE Prope
5 13
SITE PLAN PLACARD SHOWING ADDITIONAL POWER
0
Q
c
Property of Vivint Solar
Property of Vivint Solar WARNING
10
SOURCE AND DISCONNECT LOCATIONS. PLACARD
E
a
3 WARNING
PHOTOVOLTAIC AC DISCONNECT INVERTER OUTPUT CONNECTION
'••
SHALL BE MOUNTED ON EXTERIOR OF ELECTRICAL
0
ELECTRICAL SHOCK HAZARD
C6
RATED AC OUTPUT CURRENT: A DO NOT RELOCATE THIS OVERCURRENT DEVICE
PANEL (only when necessary)
—
DO NOT TOUCH TERMINALS. TERMINALS ON BOTH-
NOM. OPERATING AC VOLTAGE: ••• V Property of Vivint Solar
Property of Vivint Solar
D
THE LINE.AND LOAD SIDES MAY BE ENERGIZED IN - Property of Vivint SolarPHOTOVOLTAIC POWER SOURCE DC DISCONNECT /1
THE OPEN POSITION 11 14 PV disconnect
PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID RATED MAXIMUM POWER POINT CURRENT (IMP) •" A rapid shutdown
Property of Vivint Solar 7
SHUTDOWN RATED MAXIMUM POWER POINT VOLTAGE (VMP) ...V placard indicated on E.3
--
Property of Vivint Solar MAXIMUM SYSTEM VOLTAGE (VOC) "• V
PHOTOVOLTAIC DC DISCONNECT SHORT CIRCUIT CURRENT (ISC) ...A
O
8
Property of Vivint Solar Property of Vivint Solar
O
•'• - value calculated for each
account, for specific value see the
previous warning label page
•
o
11
14
4 7
v
m
ROOFTOP ARRAY$ 12
6 6 6
2 4 13 IF APPLICABLE
EVERY 10' AND
WITHIN V OF
o
ELBOWS ,yo�90 3 9
3 3 3
1 1 2o
m
ca
G� G20
5 5 5 5 5
5
0,
s
5 9
<s
m
uei
- MICRO -INVERTER 9
O
' Z
m
SYSTEMS DC
W W
J
N
Z N
9 DISCONNECT
•. INSIDE
[OR]
SHEET
SOLAR INVERTERS
— — —
COMBINER PANEL VISIBLE/LOCKABLE VIVINT SOLAR METER` VISIBLE/LOCKABLE
— _ _ _
SUB PANEL MAIN SERVICE
NAME:
12 (UNCTION (MAY BE ON ROOFTOP (WHEN USED) A/C DISCONNECT (WHERE REQUIRED) A/C DISCONNECT WHEN REQUIRED) DISCONNECT PANEL
5
STRING -INVERTER BOX INTEGRATED WITH
(WHERE REQUIRED)
1O 1O
E • w
ARRAY)
TYPICAL SOLAR GENERATION INSTALLATION
INSIDE PANEL
�o a tu
SYSTEMS
(NOT ALL DEVICES ARE REQUIRED IN EVERY JURISDICTION)
3 o -
SHEET
NUMBER:
ALL STICKERS DESCRIBED HERIN SHALL BE MADE OF WEATHERPROOF
THESE PLACARDS SHALL BE PLACED ON ALL INTERIOR AND EXTERIOR DIRECT-CURRENT (DC) CONDUIT, ENCLOSURES, RACE -WAYS, CABLE
ADHESIVE, THEY SHALL BE REFLECTIVE, THEY SHALL CONTAIN NO
ASSEMBLIES, JUNCTION BOXES COMBINER BOXES, AND DISCONNECTS TO ALERT THE FIRE SERVICE TO AVOID CUTTING THEM. MARKINGS
'SMALLER -THAN 3/8° WHITE ARIAL FONT -TEXT, AND HAVE A RED
SHALL BE PLACED ON ALL DC CONDUIT EVERY 10 FT (3048 MM), WITHIN 1 FT (305MM) OF TURNS OR BENDS AND WITHIN 1 FT (305 MM), ABOVE
Q
BACKGROUND, UNLESS OTHERWISE DEPICTED OR DESCRIBED.
AND BELOW PENETRATIONS OF ROFF/CEILING ASSEMBLIES, WALLS OR BARRIERS
W
p !`� '
Z+ A
-- 1
N 2m INSTALLER: MINT SOLAR . i THOMPSON RESIDENCE
E 5.0 m m ELEC. m INSTALLER NUMBER: 1.877.404.4129 v'�/'nT� l, �,
p
PHOTOS ~ v . r . c cHlco cnsssi3
DRAWN BY: JC S: 5319217 1 Last Modified: 916/2017 UTILITY ACCOUNT NUMBER: 42376594174
x
7
I Y f
i 41k
Qf
it
X.
Jt
13
y e
C i Z = INSTALLER:VIVINT SOLAR
15 PARSLEY LN
E 5.1 mm ELEC. m I.STAIIERNUMBER:1.877.404.4129 df��ri� ����Ll THOMPSON RESIDENCE
p PHOTOS " CH CO, CA 95973
DRAWN BY: JC S: 5319217 Last Modified: 9!6/2017. UTILRY ACCOUNT NUMBER: 42376594174
www.jinkosolar.com' + �• -fin
PERC, .
i ® 0 ® ®
• +,
1• O O - O o
1500V Avoilable�
tolerance-of ••
KEY FEATURES
' 1000V , High Voltage e
1000V standard: 1500V option lowers BOS costs and yields better LCOS '
Innovative Solar Cells • +
Four busbor cell technology improves module efficiency
PID -Free
!o m:
World's IsIPID-Free module at85C/85%RH
Low -Light Performance
New glass iec hnology improves light absorption and retention P
.<
• ��++ Strength and Durability 1
t '
saoow Certified For nigh snow (540OPol and wind 1240OPol loads
Weather Resistance'
+nnsuur Certified for salt mist and ammonia resistance t • ` -
_ LINEAR PERFORMANCE WARRANTY
• • • - 10 Year Product Warranty 25 Year Linear Power Warranty
• IS09001:2008 Qualily Standards
• IS014001:2004 Environmental Standards
• OHSAS18001 Occupational Health 3 Safely Standards. o-
• 100%®- Linear performance warranty
Nomenclature: - - = 9796. Aatll+ -' Standard performance-orranty `
JKM300M 60 _ - T 9s% fa^a1 vis+ue /rom ✓;nk
Coda FrnmetBacksheel code eeniflcalionm gopy. _ •K o Saar'S +ane
nWl 81-kMh1le null WON
�" .•Q a�, -
0 BlacklBlwk V +'15M
^�,�±-}'�'
us
O i CE,years
®nLISTEDr .. ^
t
IDI(Im IUIII Iilll
�mun Ilml um
I[mlllul®I 0!1
Ilfl>1(Illl�ll( �,I�VI ai?
�Im(Illuul �Ilnlc
I'�mulrmlm aurum
�Illluu�ltl ��
(�[�lIIg1M�(IIII(�(ull ��
DW �IIIIIIIIIIrlllll
Packaging Configurations'
kao boxes.One pallet 1 - r'
26pcs/ box , 52pcs/pallet, 728 pr-s/d0'HQ Container -
• a
Current -Voltage 9 Power -voltage
Curves(29a1N)
Temperaturo 0ependen
of IsC,VaaPmax
.r
F!��
■Aoe
Module Type JKM,280101-604 JKM285M-60-V JKM290M-60-V JKM295M-60-V
N ,p M ! � :\ 10 to !M •
• ,ratagef V; col l^iereralm )'
'Mechanical
Cell Type
Characteristics
. Mono -crystalline PERC 156x 156mm (6:Inch)
`��y��i31♦,,29;;32V...:r.',�299V^`7'3_2.2Vy.r.,302,V,,..�+;32t4Vn.S}30:6V,.,
_ -
Nn of rvlk
- 60 (fix 10)- Fe~
Dimensions
1650.992:40nun (G4.97.,39.06.1,57 orc11)
Weight
19.0 kg (41 .9 lbs.) , !j
r
Front Glass
3.2mm,.High Transmission, Low -.Iron,,— i
S1;7>72,h,..
AR Coating -Tempered Glass % -- 1
Operating Temperature(T) 40'C- 85"C
I Frame
Anodized Aluminium .Alloy
- S)
-r
Power tolerance �~ r!= , • - �-` • . ' 0 -*3 k. - .
Junction Box
IP67 Rated
Output Cables
12 AWG, Length:900mm (35,13 inch)
Fire type
Type t'
Nornitiaboperating iceil ternperattire .. (NOC1) V 7 {` e`er¢ _Z22°
`� �
_ _
;2;47. .
Module Type JKM,280101-604 JKM285M-60-V JKM290M-60-V JKM295M-60-V
, JKM3001VI-60-V
rrr - =u �1 + •i SfC'; NOCT3t rlt iC`, '' NOCT STC w!e(I
e. / LrvOCTgj^ NOCT
•�285Wp
SIC! NOCTi
Maximum Power (Pmax) .280wp 209wp 212Wp 290Wp 216Wp 295Wp 224Wp
300Wp; 227Wp -
`��y��i31♦,,29;;32V...:r.',�299V^`7'3_2.2Vy.r.,302,V,,..�+;32t4Vn.S}30:6V,.,
..
1_326'V° 303V:_
Maximum Power Current (Imp) 8.81A 7.01A 8.9A 7,12A 9,02A ' 7,15A n 9.1A 7.32A
9.3A'r ' 7.4A - I
•��+"_'�'t98 91r ^ 36 ZV; 36,N 6;4V - k39 SV36�BV, 39:71%7 V
i,
'+4b
>r :.:..°„ _ ••.., :v -r.•' r�._.::.. �#tle�-...ltd.:-:..- »J. .S .:.w•--... Vii.__.
Short-circuit Current (Isc) 9,49A ''7,62A 9.51A 7.72A 9.55A 7,81A •9.61A - 8.01A
9.83A 8.12A
S1;7>72,h,..
Operating Temperature(T) 40'C- 85"C
Maximum system voltage • - } '_ i500VDC(UL), M t w rT �t'7�^r"t,
Maximum series fuse rating 15A
- S)
-r
Power tolerance �~ r!= , • - �-` • . ' 0 -*3 k. - .
Temperature coefficients of Pmax
Temperature coefficients of Voc - 1, � � - ' M .-0:29%PC
Temperature coefficients of Isc _ 0.05%/*C
?� '
Nornitiaboperating iceil ternperattire .. (NOC1) V 7 {` e`er¢ _Z22°
`� �
_ _
;2;47. .
STC: : Irradiance 1000W/ml Cell Temperature 25`C AM 1-.5
NOCT: 'if= irradiance 800W/m,' Ambient Temperature 20°C AM=1.5 '
'-Wind Speed 1 m/s
' Power measurement tolerance: t 3%
CAUTION: READ SAFETY AND INSTALA.ATION INS1-RUCTIONS BEFORE USING THE PRODUCT-
Jir•ko Solar Co_ Ltd: All rights reservec specifications included in this dalasheet are subject to change without notice,.
US -MKT -300M -00-V v1.0 rev2017 -
-
ar
i
-;I. 1 3; ----1
Enphase Microiniierters
Enphase
Designed for higher powered modules, the smart grid -
ready Enphase IQ 6 Micro'"' and Enphase IQ 6+ Micro'"
IQ6 and IQ 6+
are built on the sixth -generation platform and achieve
/�
Mi c r®i n ve rte rs,
the highest efficiency for module -level power electronics
and reduced cost per watt.
Part of the Enphase IQ System, the IQ 6 and IQ 6+ Micro
integrate seamlessly with the Enphase IQ Envoy',
Enphase IQ Battery", and the Enphase Enlighten'
'monitoring and analysis software. .
The IQ 6 and IQ 6+ Micro are very reliable as they have
fewer parts and undergo over 1 million hours of testing.
Enphase provides an industry-leading warranty of up to
25 years.
Easy to Install
Lightweight
Simple cable management
Built-in rapid shutdown (NEC 2014)
Productive
Optimized for high powered modules
Supports 60 and 72 -cell modules
Maximizes energy production
Smart Grid Ready
Complies with fixed power factor, voltage and
frequency ride -through requirements
Remotely updates,to respond to changing
grid requirements
Configurable for varying grid profiles
U`
To
EN PHAS E.
learn more about Enphase offerings, visit enphase.com
Enphase IQ b and IQ b+ Microinverters
INPUT DATA (DC)
IQ6-60-2-US AND IQ6-60-5-US
IQ6PLUS-72-2-US AND IQ6PLUS-72-5-US
Commonly used module pairings'
195 W - 330 W +
235 W - 400 W +
Module compatibility
60 -cell PV niodules only
60 -cell tied 72 -cell PV rnudules
Maximurn input DC voltage
4E V
62V
Peak power tracking voltage
'2/ V - 37 V
2/ V - 45 V
Operating range
16V -48V
16 V - 62 V
IVlin/Max start voltage
22 V / 48 V
22 V / 62 V
Max DC short circuit current (module Isc)
15A
15 A
hI
Overvoitage class DC port
II
II
DC port backfeed under single fault
0 A
0 A
PV array configuration
1 x. 1 ungrounded array; No additional DC side protection
required;
AC side protection requires max 20A per branch circuit
OUTPUT DATA (AC)
IQ6-60-2-US AND IQ6-60-5-US
IQ6PLUS-72-2-US AND I06PLUS-72-5-US
Peak output power
240 VA
290 VA
Maximum continuous output power
230 VA
280 VA
Nominal voltage/range2
240 V / 211-264 V 208 V (10) i 183-229 V
240 V / 211-264 V 208 V (1(0) / 183-229 V
Nominal output current
096 A 1.11 A
1.17 A 1.35 A
Nominal frequency
60 Hz
a
60 Hz
Exlanded hequency Lange
47- 68 Hz
47 - 68 Hz
Power factor at raled Dower
1.0
1-0
Maximum units per 20 A branch circuit
16 (240 VAC)
13 (240 VAC)
14 (single -Phase 208 VAC)
11 (single-phase 208 VAC)
Overvoltage class AC port
III
III
AC port backfeed under single fault
0 A
0 A
Power factor (adjustable)
0.7 leading_. 0.7 lagging
0.7 leading... 0:7 lagging
EFFICIENCY
@240 V @208 V (10)
@240 V @208 V (10) j
CEC weighted efficiency
97x7 °% 96.5%
97.G% 96.5%
MECHANICAL DATA
l
Ambient.ternperature.range. - _ __ __ _
-40?C.to_+65°C
Z_ _.
Relative humidity range
4°i to 100% (condensing)
Connector type
MC4 or Amphenol H4 UTX
-
Dimensions (WxHxD)
219 mm x 191 mm x 37.9 rnrn (without bracket)
Weight
1.5 kg. (3.3 lbs)
Cooling
Natural convection - No fans
Approved for wet locations
Yes
Pollution degree
PD3
y
Environmental category / UV exposure rating;
Outdoor - NEMA 250; type,6 (I P67.)
- - - i
FEATURES
Communication
Power. line
R
Monitoring
Enlighten Manager and MyEnlighten monitoring options
Compatible with Enphase IQ Envoy
Compliance
—U, UL-1,,741/IEEE1547, FCC Part 156CIass
B;, ICES-0o03�0ass:B,
CANLCSA.C22.2 NO. 107:1-01
This product is UL Listed -as PV Rapid Shut Down.Equipment and'conforms with NEG-2014�and'
NEC-2017'section169012 andC22.1-2018,Rule 64=218 Rapid Shutdown,of PV Systems, for -AC
andiDC conductors, when installed according manufacturer's instructions.
1. No enforced DC/AC ratio. See the compatibility
calculator at enphase:com&m-us/support/module-com
atn� ibillty,
2. Nominal voltage range can be extended beyond.nominal if required by the utility.
r
To learn more about Enphase offerings, visit enphasexam
'J 2017 6aphase Energy. All rights reserved All trademarks cr brands used are the property of cnphase Energy, Inc, E N P H A S E.
^2017-03.15 \�
D
dOa EcoFasten Solar°'.
d Committed to the connection
i�
Contents
Pg. 1......................................................................................................................................... Assets'of Design
Features
System Components
Pg. 2.......................................................................................................................... Rock -It 2.0 Mount Assembly
Rock -It 2.0 Coupling Assembly
Pg. 3........................................................................................................ Rock -It 2.0 Hybrid Mount Assembly
Rock -It Clip SS Assembly
Pg. 4....................................................................................................................................... .............. Array Layout
GreenFasten Flashing Install
Pg. 5•..................................'......................_...................................................................... Rock -It System 2.0 Install
Pg. 6 ....................................... ................................. .................................................. Ground Lug Install
Rock -It Clip SS Install
Pg. 7 -11.............................................:....:.................:.....................................................• Standoff Spacing Tables
Snow Load 0-20 psf
Snow Load 21-30 psf
Snow Load 31-40 psf
Snow Load 41-50 psf
Snow Load 51-60 psf
Pg. 12 .......... .:..................:............................................................._.....:.......................... Grounding Information
Bonding Assembly and Bonding Path
pg. 1........................................Thermal Thermal Expansion and Bonding
3;
Bracket Spacing
Staggered Layout
Cantilever
Pg. 14 ...... :...........
:.:.:.:...... ............. ::.............. :........ :........................................... Evaluated, Compatible Modules
System Specifications
www.ecof6stensolar.com info@ecofastensolar.com 877-859-3947
ROCK -IT SYSTeM 2.0
Designed with the installer in mind.
EcoFasten Solar specializes in solar roof attachments that arc fast and easy to install, straightforward, secure and
cost-effective. EcoFasten offers a wide variety of standard products as well as custom solutions, for a one-stop source
for all of your rooftop anchoring needs. Products are rigorously tested and approved above and beyond industry
standards in-house and by third party agencies. EcoFasten's patented conical sealing system has been in
service in the snow guard and solar industries for two decades.
FeaTures
• Fastest, easiest to level system on the market
• Conforms to L11- 2703 First Edition
• ClasS A Fire Rating with Type 1 moriules
• Integrated electrical bonding
• SIMPLE- only 4 components
• North-South adjustability
• Only one tool required (1 /2" deep well socket)
• Vertical adjustment of Y-4"
S9STem comPonenTS* - reouireD
ROCK -IT SLIDe ROCK -IT 2.0 ROCK -IT 2.0 COUPLInG
4" For COMP SHInGLe MOunT & LoaD BeannG F=OOT
8" For TILe
SYSTem comPOnenTS* - OPTIOnaL
ROCK -IT 2.0
I 9Br_ID MounT
(ReFer TO PG. 5)
ROCK -IT CLIP SS
(ReFer TO PG. 6)
ROCK -IT 2.0
Array SKIrT
A
U_EcoFasten
Solar
EcoFasten Solar products are protected by the following U.S. Patents:
8,151,522 8,153,700 8,181,398 8,166,713 8,146,299
8,209,914 8,245,454 8,272,174 8,225,557 9,010,038
9,134,040 9,175,478 9,212,833
*Components for use with 32mm modules are available as special order. Components for use with 32mm modules are labeled as such on
packaging. Side profile of Mid -Clamps on Rock -It 2.0 Mount and Rock -It 2.0 Couplings is slightly different for use with 32mm modules.
Please refer to evaluated, compatible modules on page 14.
www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 1
ROCK -IT 2.0 MounT ASSeMBLJ-
NOTe: ITemS 1-7 SHIP assemBLeo
iTem 6 Pre-TOroueo
1 5/16"-18 Hex Flange Bolt (orHexw/starwasher) 300 Series SS
2 Rock -It Mid -Clamp 6000 Series AL
(fig, A: Mid -Clamp for use with 32mm modules)
3 Conical, Spring 300 Series SS
4 Rock -It Shelf 2.0 6000 Series AL
5 Flange Level Nut 300 Series SS
6 Rock -It Pedestal 6000 Series AL
7 Rock -It -Tie Plate 6000 Series AL
8 Rock -It -Slide -Tile 2.0 6000 Series AL (sold separately)
9 Rock -It -Slide -Comp 2.0 6000 Series AL (sold separately)
o�
O -
ITems 8-9 are accePTaBLe
r BracKeTS FOr use WITH THe
ROCK -IT 2.0
(SOLD separaTeLY )
ROCK -IT 2.0 COUPLING aSSel'1'1BLY
NOTe: ITet71s 1-4 SHIP a552rr1B1 eD
1 5/16"-18 x 1.25" or 1.5" Hex Flange Bolt 300 Series SS
2 Rock-It-Coupling-MiclClamp 6000 Series AL
(fig. A: Mid -Clamp for use with 32mm modules)
3 Conical Spring 300 Series SS
4 Rock -It -Coupling -Shelf -2.0 6000 Series AL
5 Load Bearinq Foot
fig: A
(32mm)
www.ecofastensolar.com info@ecofasiensolar.com. 877-859-3947 2 j
ROCK -IT 2.0 HYBRID MOI. nT ASseMBLY
NOTe: ITems 1-10 SHIP assemBLeD
-,T
1 1 5/16"-18 x 1.25" or 1.5" Hex Flange Bolt 300 Series SS
2. Rock-It-Coupling-MidClamp 6000 Series AL
(fig. A: Mid -Clomp foi use with 32mm modules)
3 Rock -It -Coupling -Shelf -2.0 6000 Series AL
4 Crushable Spacer - Cardboard or Similar
5 Flange Level Nut 300 Series SS
-`
._. 6 Rock -It Pedestal 6000 Series AL
7 3/8" ID Star Washer 300 Series SS
J
8 3/8"-16x 3" Hex Tap Bolt 300 Series SS
9 5/16"-18 x 3/8" Hex Serrated Flange Dolt 300 Series SS
10 Rock -It Tie -Plate -T 6000 Series AL
n
fig. A
(32mm)
ROCK -IT CLIP SS ASsemBLY
NOTe: iTems 1-3 SHIP assemBLeD
1 Stainless Steel Carriage Bolt -.313-18X.75
2 Rock-lt Clip SS -
3 Stainless Steel Flange nut .313-18
www.ecofastensolar.com info@ecofastensolar.com
877-859-3947 3
Array L_agOUT
Find the required structural attachment points.
Mark these using a vertical (N -S) chalk line on the
center of the rafters.
Spacing may vary depending upon project specific
structural requirements; i.e. high snow and wind
load areas may require lesser bracket spacing in
the E -W axis vs. the maximum spacing. Max spacing
is 48"for portrait orientation and 72"for landscape
orientation. Consult project layout diagram for
project specific bracket spacing on the roof.
Install Rock -It Mounts to predetermined mount
spacing.
• The array skirt sections are the width of a typical
60 cell module — use the array skirt as a guide to
lay out module placement.
Note: The distance between the rows of mounts is calculated by the module dimension N -S plus 1 3/8"
(35mm). Lag screw should be installed as close to center of exposed shingle as possible. The minimum
distance between the lag screw and the edge of the shingle is 1/2".
GreenFasTen FLasHinG insTaLL
position for each GreenFasten flashing.
vertical lines to mark the installation
2 Drill a pilot hole (1/4"diameter) for the lag bolt. Backfill with sealant. EcoFasten Solar
recommends an EPDM mastic.
3 Insert the flashing so the top part is under the next row of shingles and pushed far
enough up slope to prevent water infiltration through vertical joint in shingles. The
leading edge of flashing must butt against upper row of nails to prevent turning
when torqued.
4 Line up pilot hole with GreenFasten flashing hole.
Insert the lag bolt through the EPDM bonded washer, the Rock -It slide, the gasketed
hole in the flashing and into the rafter.
Torque: The range is between 100-140 torque inch -pounds depending on the type
of wood and time of year. The visual indicator for proper torque is when the EPDM
on the underside of the bonded washer begins to push out the sides as the washer
compresses. If using an impact wrench to install the fasteners be careful not to over
torque the fastener. You may need to stop and use a ratchet to finish the install.
"The Engineer of Record shall check capacity of rafter to support lag screw loading.
www.ecofastensolar.com info@ecofastensolar.com 877-859-3947
ROCK -IT SYSTeM Z.O inSTaLL
Install Eco Fasten Solar Flashing with Rock -It Mounts
Follow EcoFasten Solar Install instructions for flashing and bracket install (GreenFasten shown above)
Optimum vertical distance between lag bolts is 1 3/8"plus module dimension
Set mounts on eave most row so that the Rock -It Pedestal is an the South end of Rock -It Slide
Set mounts on all upper rows so that the Rock -It Pedestal is on the North end of Rock -it Slide
2 Install Array Skirt on Eave Mounts
Loosen Hex Flange Bolt in Rock -It Mid -Clamp
Slide Array Skirt into front channel on Rock -It Shelf
Tighten Hex Flange Bolt to engage the Array Skirt
3.5 Install Rock -It Couplings
Snap Load Bearing Foot into the bottom of every Rock -It Coupling prior to mounting on the roof
(Each Load Bearing Foot is set to same height as the Rock -it Mounts- adjust accordingly)
On eave row only, slide Rock -It Skirt into front channel on Rock -It Coupling
On eave raw only, tighten the west most Array Skirt bolt on Coupling first to 150 in -lbs., followed by tightening the east bolt, drawing the Array Skirt sections together
Upon final levelling of entire array (see step 11), utilize the Levelling Nut to ensure that the Load Bearing Feet engage the roof surface
NOTE: If a coupling lands on a rafter, the Hybrid Mount* should be used in place of the Rock -It Coupling (refer to image 3a)
6 Align and
Mount can be made in the field by assembling a coupling to,a mount pedestal, or by purchasing separately
Straighten First Row of the Rock -It System with Array Skirt
Use North-South adjustment of the Roc-ItPedestal to straighten array skirt
Torque screw on side of Rockat Pedestal to 150 in -lbs to secure it to the Rock -It Slide
Adjust Flange Level Nut to level the system (optional — can be leveled during or after installation)
7-10 install 1 st Row of PV Modules
Slide upslope. Rock -It Mounts down to engage top of first:module
Install Rock -It Couplings on the upslope side of 1 st row of panels
Torque 1st and 2nd row of Mid -Clamps on Rock -It Mounts and Rock -It Couplings to 150 inabs. (Torque to 130 in -lbs. when installing with 32mm modules)
Install balance of PV modules, ensuring that the Rock -It Pedestals are in the appropriate position, then torque Mid -Clamps to secure modules
level the Rock -It System
• When assembly is complete, level the entire system by adjusting Flange Level Nuts (Flange Level Nuts have no torque value)
www.ecofastensolar.com info@ecofastensolar.com 877-859-3947
GrounDinG LUG InSTaLL
Necessary Components:
Burndy CL50-1 TN Ground Lug (UL Listing #KDER,E9999)
Note: Drill and deburr hole in Ground Lug prior to installation
14 AWG - 4 AWG Copper Ground Wire*
8-32 x 0.5" Serrated Flange Head Bolt (300 Series SS)
8-32 Serrated Flange Nut (300 Series SS)
11/32" and 1/4" wrenches or ratchets/sockets
1 Insert the Flange bolt into the module ground hole. Place Ground Lug over the
bolt and turn to desired orientation.
2 Install Flange Nut.
3 Tighten Flange Nut/Bolt.
4 Place wire in Ground Lug channel and tighten set screw to complete assembly.
Torque Values:
14-10 AWG= 20 in -lbs.
8 AWG= 25 in -lbs.
6-4 AWG= 35 in -lbs.
*Minimum of 1/4" clearance required between bare copper wire and aluminum.
ROCK -IT CLIP SS InSTaLL
r1CCcyltnfue MLlttitlr�l.GG;JttVns
p �
rrl ,i!p, 'wY•,
rrlln tefn
R4
i' ..
.I W'
1 Locate all parts
-Locatethe Rock -It Clip SS, micro-inverter/power optimizer, and the section of the module frame in which you will be mounting
the micro-inverter/power optimizer. See fig. A for acceptable mounting locations.
2 Install the Rock -It Clip SS
• Slide the Rock -It Clip SS onto the lip of the module frame.
• Slide the micro-inverter/power optimizer into the opposite lip of the Rock -It Clip SS.
• Tighten the bolt to 20 ft -Ib to clamp the Rock -It Clip SS to the module frame and the micro-inverter/power optimizer to the
Rock -It Clip SS.
• Ensure that the lip on the clip is tight against the frame and that the micro-inverter/power optimizer flange is tight against
the Clip Flange to avoid rotation during tightening.
iM
www.ecofastensolar.com i nfo@ecofasten sola r.conn 877-859-3947 6
Snow Load 0-20 psf
Modules in Landscape. r �:
Wind Speed
Exposure
Category
2:12 < Roof Pitch < 6:12 7:12 < Roof Pitch < 12:12
ASCE 7-05
ASCE 7-10
Zone 1
Znne 2
Zone 3 Zone 1 Zone. 2 Zone. 3
ne.1
91
_Zone 2_.
X53-33.
B
159
93
59 v t
85 mph
110 mph
C
114
67
42 88 88
50 z r
�42 �
r 50
D
96
56
1 74 74
35;;.
.�32'
'20 a .�52� .
8
146
85
54�� 1111111111311111111111.
90 mph
115 mph
C
104
61
38 80 80
46
46
D
88
51
32 83 68 68 h
35
22 56
8
123
72
45 95 95
100 mph
125 mph
C
88
51
32 83 68 68
B a
100 mph:t�T�
D
/4 •
43
21 /u 8% 5/
R"118 47y
h 39 c
B
98
57
36 93 76 76
110 mph
140 mph
C
70
41
26 66 54 54
B
D
59
34
22 56 46 46
40
23
B
85
50
31 81 66 66
120 mph
150 mph
C
61
36
22 58 47 47 #�
26
D
51
30
19 49 40 40
Notes:
® Spacing Governed by Snow Load
1.) Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff.
however the designer must round down to meet appropriate rafter spacing
2 ) Maximum allowed spacing approved by EcoFasten Solar is 72" t.
3.) Maximum allowed standoff capcity = 547# (per testing results)
4 ) Includes additional factor ofsafety of 1.5 for larf pullout Capacity
5.) Values based on a maximum module width of 40"
6.) Based on Risk Category II (ASCE 7-10) structures less than 30 feet in height
7 ) All adjustment factors are set to 1• No site sper:ifir. engineering is included in this table
Snow Load 0-20 psf
Notes:
-Spacing Governed by Snow Load
1.) Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff
2.) Maximum allowed spacing approved by EcoFasten Solar is 48" p
3.) Maximum allowed standoff capcity = 547# (per testing results)
4,) Includes additional factor of safety of 1.5 for lag pullout capacity
5,) Values based on a maximum module length.of 70"
6.) Based on Risk Category II (ASCE 7-10) structures less than 30 feel in height
7.) All adjustment factors are set to 1. No site specific engineering is included in this table
7 i
www.ecofastensolar.com info@ecofastensolar.com { 877-859-3947
d
a
.7
0
o le P.ts
Wind
Speed
Exposure
—Cate o
2:12 < Roof Pitch < 6:12 7:12 < Roof Pitch < 12:12
ASCE 7_-05.
ASCE. T-10-
ne.1
91
_Zone 2_.
X53-33.
—Zone 3 Zone_1....
_Zone.2—
.Zone 3. :
85 mph:*.C+
x `
14} ar 65
38!,
_
w 4 r T' 61'j
50 z r
�42 �
r 50
►
�.srihr
_� _ E)
55. ra.
.�32'
'20 a .�52� .
__42.y, i
B
83
49
30
46
46
90 mph
115 mph
C
59
35
22 56
D
50
70
29
44°7.e-
1'8 47
=v 2_6=
38
54,:..
38
54"►-"
B a
100 mph:t�T�
e
i_
R"118 47y
h 39 c
39�
t
56
33
40
20 53
32_r
43
.;.1
B
43
110 mph
140 mph
C ,
40
23
14 38
31
31
D
34
19
28
12 32
26
26
8 46'
K3_7:7_-
"r3g"
120mph'=7
150mph
r -qC 5..
' 35w
X20
'""12 ' -F 33 �"
1i'�27.�
? 27�
a .
01� f
. ' rD
F .� 29Y �
k � 17�
r' 10_ a .213"! 4
. -22�
.22 # ,
Notes:
-Spacing Governed by Snow Load
1.) Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff
2.) Maximum allowed spacing approved by EcoFasten Solar is 48" p
3.) Maximum allowed standoff capcity = 547# (per testing results)
4,) Includes additional factor of safety of 1.5 for lag pullout capacity
5,) Values based on a maximum module length.of 70"
6.) Based on Risk Category II (ASCE 7-10) structures less than 30 feel in height
7.) All adjustment factors are set to 1. No site specific engineering is included in this table
7 i
www.ecofastensolar.com info@ecofastensolar.com { 877-859-3947
d
a
.7
0
Snow Load 21-30 psf
Modules in Landscape
Wind Speed
- Exposure +Eon
Roof Pitch < 6:12 7:12 < Roof Pitch < 12:12 -
ASCE 7-05 ASCE 7-10
Cate o
Zone 2
Zone 3 Zone 1
Zone 2
Zone 3
85 mph
mph
110 mph
115 mph
B
C
D
C
B
93
67
56
85
61
51
72
59 ;+
42 ��.66
35B
5490
38D
32
45
SS mpha,
9.
110 'mph
100 mph
125 mph
C
88 51
32-^ 018. a•'lil�
ISE
57
57
49
D
74 43
27 6S, :'
C
+
6
98, 57
36 B"
r
'�
54
54
110 mph
140 mph
C
70 41
26 66
�4 y
� D'+� �
i50p^•
t "42:
D
59 34
22 56
46
46
B
56,
B
85 50
'31 SO
66
66
120 mph
150 mph
C
61 36
22 58
47
47
D
34
0
F. 51 .30
19 49
40
40
Notes:
Spacing Governed Govened by Snow Load +
1.) Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff.
however the designer must round down to meet appropriate rafter spacing
2.) Maximum allowed spacing approved by EcoFasten Solar is 72"'. +
3.) Maximum allowed standoff capcity = 5479 (per testing results)
4.) Includes additional factor of safely of 1:5 for lag pullout capacity
5.) Values based on a maximum module width of 40"
6.1 Based on Risk Category II (ASCE 7-10) structures less than 30 feet in height
7.) All adjustment factors are set to i. No site specific engineering is included in this table
Snow Load -21-30 psf ,
,, �: ,. �� .tt M'aur 40 .bt#rait 1 ' �' "�=�ti`.�
Wind
Speed
Exposure
2:12 <
Roof Pitch
< 6:12 `
'7:12 < RoofPitch < 12:12
Zone 1
Zone 2
Zone 3
Zone 1, Zone 2 Zone 3
ASCE 7-05
ASCE 7-10
Category
SS mpha,
9.
110 'mph
F�awnvF 8 {�
CT
,+65�
55;
rR 587- A
r+�36"t
,.,9 33 i+
trr�424+ `f
B4
49
30
90 mph
115 mph
C
59
35
22
r
'�
V S,50
41i z
e 26 18
38 38
00 m h
f
I +T . '1�;r
125 mph
(a a^
�4 y
� D'+� �
i50p^•
t "42:
a 29 SKS
26 1i
+ X18 k
1;.•15,:
39' h rt,39 Z- '
Fes`. 40 _ '.32� ,., � 321'*
B
56,
33
20
110 mph
140 mph
C
40'.
23
14
38 31 31
D
34
19
12
32 26 26
120 mph,
`
150,mph
ftB� '
Cs
1,49`28
35',
20
18`y
, r37.; t 37 *�
33, 1Y. 27 7 27
J,
y
n n
� �
10M
28 ir+
14. Notes:
Spacing Governed by Snow Load
1.) Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff
2.) Maximum allowed spacing approved by EcoFasten Solar is 48" t'
3.) Maximum allowed standoff capcity = 547# (per testing results)
4.) Includes additional factor of safety of 1:5 for lag pullout capacity
5.) Values based on a maximum module length of 70" ,
6.) Based on Risk Category II (ASCE 7-10) structures less than 30 feet in height. , ).
I 7.) All adjustment factors are set to 1. No site specific engineering is included in this table .
s
www.ecofastenso'lar.com. info@ecofastensolar.com 877-859-3947 s
Snow Load 31-40 psf
Modules in Landscape
Wind Speed
Exposure ,
Category
2:12 < Roof Pilch < 6:12 7:12 < Roof Pitch < 12:12
ASCE 7-05
ASCE 7-10
Zone 1
Zone 2
Zone 3 Zone 1
Zone 2
Zone 3?
65 mph
110 mph
B
C
D
`' 'ar
U 83
Aa
59
42 5t
35 '` U.
51
�'
5t,,
x`51
67
56
90 mph
115 mph
C
83
54
38 t 5;?
'51
1,
100 mph',,
61
100 mph
125 mph
D
B.
C
".6`3
Q3
'
51
32 SS
45 51
32
_ 51,
52 -
51
C 40 23
14
D
- 74
43
27 a1,. "
fit.
sp . �.
�►�
B K
57
36 8'1`
SA
' 51
` •
70
110 mph
140 mph
C
41
26 bt
s v
D
59
34
2'L si
46
46
120 mph
150 mph
B y
C
50
36
31 $1
22 1
-
61
47
47
D
51
30
19 49
40
40
Notes:
Spacing Governed by Snow Load , 4.
+C
1.) Valvas in ahove lahia represent the maximum allnwahle spacing in inches fnr pullnut fomes only nn FcnFasten Solar standoff,
however the designer must round down to meet appropriate rafter spacing
2.) Maximum allowed spacing approved by EcoFasten Solar is 72"
3.) Maximum allowed standoff capuily = 5474 (per testing results)
4.) Includes ddditiunal factur of safely of 1.5 for lay pullout cupacily ;
5.) Values based on a maximum module width of 40" "}
6.) Based on Risk Category it (ASCE 7-10) structures less than 30 feet in height I
7.) All adjustment factors are set to 1. No site specific engineering is included in this table tj
Snow Load 31-40 psf
'i
Madtatas4A.P orfrai# F
Wind
Speed
Exposure 2:12 < Roof Pitch
:....Cats o � -. Zone.1._ ;-Zone-2
< 6:12 7:12.< Roof Pitch < 12:12 '
ASCE-7-10;
� Zone 3 Zone-.1�-- �-Zone
�A�,,!_SCCE�--7�.-0�5-
{ 85 mph
e110mph
,4C c� yr 38 i'
B '` 49
r�:1-24y:"
30
90 mph
115 mph
C 35
22
D 29
4_1 -,-t
4
18
226
100 mph',,
•
B 33
20
110 mph
140 mph
C 40 23
14
D 34 19
12 26 26
� p j
�►�
Y;120mph,,
GpY"uyrrc�Dtw'>
150mphr
�y-C yLrX35+'-� t20
;.N29`?aa+r1.7,,.
27� i S•i27;?---
i. %10`.'.� 28 ":': 22 A. ,IiM'22'
Notes: r -
v!. Spacing Governed by Snow Load l� "
1.) Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar slandoll
F 2.) Maximum allowed spacing approved by EcoFasten Solar is 48"
3.) Maximum allowed standoff capcity = 5474 (per testing results) f
4.) Includes additional factor of safety of 1.5 for lag pullout capacity
5.) Values based on a maximum module length of 70" `
6.) Based on Risk Category 11 (ASCE 7-10) s-ructures less than 30 feet in height
t 7.) All adjustment factors are set to 1, No site specific engineering is included in this table
ri r
www:ecofastensolar.com 'info@ecofastensolar.com ' 877-859-3947-
Modules
77-859-3947
i
i.
9
i
u
Snow Load 41-50 psf
'Modules.in Landscape
WIn&S add
Exposure 2:12 < Roof Pitch < 6:12 7:12 < Roof Pitch < 12:12
Cate o Zone 1 Zone 2 Zone 3 . . Zone 1 Zone 2 Zone 3
ASCE 7-05
ASCE 7-10
7.12 < Roof Pitch < 12:12
ASCE 7-05
ASCE 7-10
3
1 Zone 2 Zone 3
Ai85 mph,
'r7
110 mph
85 mph
110 mph
C , 66: a�
'5
42
B
30
56
90 mph
D BTi< ,�
� 35 57'w.
22
B C4 '`
54 y S t
St
• ' Sh
14125
90 mph
115 mph
C �G6 ..
61
_
38 �tiati 1
r i iii
` r �f t
B ' 33
D = t s6; f
51
32
140 mph
C 23 '
14•
B f36
49
12
100 mph
125 mph
C
51
32 5: K; <
ti'S{:
5j •`
ISt,.
ti
D 6a ";'
43
27 5J'
$1 .
•r.
B- ,6p8:�
57
36
. L
110 mph
140 mph
C R ' :
41
26 ;$i
D , 59
34
22 4 art:
46
46
B
50
31
47
47
120 mph
150 mph
C 61
36
,r51.yry
22 ' ` -,kAl
D 51,
30
19 49
` 40
40
rvares: -
Spacing Governed by Snow Load
1.) Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff,
however the designer must round down to meet appropriate rafter spacing . .
2.) Maximum allowed spacing approved by EcoFasten Solar is 72"
3.) Maximum allowed standoff -apcity = 547# (per testing results)
4.) Includes additional factor of safely of 1.5 for lag pullout capacity _
5.) Values based on a maximum -module width of 40" f
6.) Based on Risk Category II (ASCE 7-10) structures less than 30 feet in height
7-) All adjustment factors are set to 1. No site specific engineering is included in this table
Snow Load 41-50 psf
Notes: -
.,is� Spacing Governed by Snow Load
1.) Values in above table represent the maximum allowable spacing in inches for pullout forces only an EcoFasten Solar standoff
2.) Maximum allowed spacing approved by EcoFasten Solar is 48" e.
3.) Maximum allowed standoff capcity = 547# (per testing results)
4.) Includes additional factor of safety of 1.5 for lag pullout capacity v
5.) Values based on a maximum module length of 70"
6.) Based on Risk Category II (ASCE 7-10) structures less than 30 feet in height
7.) All adjustment factors are set to 1. No site specific engineering is included in this table t
' r
U
a
www.ecofastensolar.com info@ecofastensolar.com 877-859-3947, 10
Wind
S eed
Exposure 2:T7rRoof Pitch,<6:12
Category Zone 1 Zone 2
7.12 < Roof Pitch < 12:12
ASCE 7-05
ASCE 7-10
3
1 Zone 2 Zone 3
Ai85 mph,
'r7
110 mph
"•...T•.!_ TBI I:
1Z��one
'._S'..
/Zone
_
,``C
B
30
90 mph
115 mph
C 35 -
22
D_ 29' "
f'B
tC
18
26
*Y100
14125
mph
mph�a"
r'29
v.y 18
B ' 33
20
110 mph
140 mph
C 23 '
14•
D 19
12
g K
2
2 �120mph1�177
ti
-A
Notes: -
.,is� Spacing Governed by Snow Load
1.) Values in above table represent the maximum allowable spacing in inches for pullout forces only an EcoFasten Solar standoff
2.) Maximum allowed spacing approved by EcoFasten Solar is 48" e.
3.) Maximum allowed standoff capcity = 547# (per testing results)
4.) Includes additional factor of safety of 1.5 for lag pullout capacity v
5.) Values based on a maximum module length of 70"
6.) Based on Risk Category II (ASCE 7-10) structures less than 30 feet in height
7.) All adjustment factors are set to 1. No site specific engineering is included in this table t
' r
U
a
www.ecofastensolar.com info@ecofastensolar.com 877-859-3947, 10
r
n l
I'
4 .
�T I
S�
I
� IIi
t; - A
Snow Load 51-60 psf
Modules .In Landscape
Wind Speed
Exposure(
Category.
-2:112 < Roof Pitch < 6:12 -
7:12 < Roof Pitch < 12:12
ASCE 7-05
ASCE 7-10
Zone 1
Zone 2 Zone 3
Zone 1
Zone 2
Zone 3,i
30
B
'550".
C
22
85 mph
110 mph
C
56
55 42
'11'
3d .
, $4 .,
110 mph
O
38
35. 35
.34 '' '.
34.
,. 3a.
D
d8
�-i 1217
19 12
2B
�:29�.i�' ..>.'17. �t c.� 10G• :'v.
90 mph
115 mph
C
S9'
38+{
24,,;;;.
34 '
D
b5'
51 32
34%
B
55
45
7. 34`
"3,4
3,4 1
'
100 mph
125 mph
C
.r}6;.
51 32
34'
DW
.
43 27
<
•
..
B
�i6
36
a r
5
Ll
110 mph
140 mph
C
1,56:
41 25
hot
r
32t,'34:
art -
D
3
34 22
' !4 ",
34;''
B
,
50 31
34,"j -';i,
.ra
34
120 mph
150 mph '
C
36 22,
;377 w `
k d'3A "'
34
51
D
1 30 _ 19
'34. ; `
'' t 34
Notes: j
Spacing Governed by Snow •_oad r 1.
1.) Values in above table represent the maximum allowable spacing in inrhes for pullout forces only on FcaFasten Solar standoff,
however the designer must round down to meet appropriate rafter spacing !
2.) Maximum allowed spacing approved by EcoFasten Solar is 72"
3.) Maximum allowed standoff capcity = 547# (per testing results) If
4.) hidudes addiliunal factur of safely of 1.5 rut lag pulluut capacity -t
5.) Values based on a maximum module width of 40"
6.) Based on Risk Category II (ASCE 7-10) structures less than 30 feet in height
k
7.) All adjustment far..tors are set to 1. No site specific engineering is included in this table
a Snow Load 51-60 psf `
t
,• ale
Notes:_ !
®Spacing Governed by Snow Load +i
1.) Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff
2.) Maximum allowed spacing approved by EcoFasten Solar is 48"
3.) Maximum allowed standoff capcity = 54?9 (per testing results)
.4.) Includes additional factor of safety of 1.5 for lag pullout capacity '
5,) Values based on a maximum module length of 70" _ 4
tl
6.) Based on Risk Category II (ASCE 7-10) structures less than 30 feet in height
7.) All adjustment factors are set to 1. No site specific engineering is included in this table
4
� t
www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 n
I
6
I
ap. I
2:12 < Roof'Pitch < 6:12
Zone -1 - —Zone 2_-_Zone.3— =—Zone•1--
24
7:12 < Roof Pitch
.—Zone -2—_ Zone 3'
Wind S eed
Exposure
.Cate o ..—
* C �
ASCE-7,05,
X85 mpfi
ASM -7-1T
X110 mp
B
30
90 mph
115 mph
C
22
100 mpti-t
-'�,
X125 mph
D
8
3 - ` Cr �;
29 18
26
g,- 'N18x
5�`'.
B
20
110 mph
140 mph
C
23 14
1120 mph,'4
mph
D
d8
�-i 1217
19 12
2B
�:29�.i�' ..>.'17. �t c.� 10G• :'v.
Notes:_ !
®Spacing Governed by Snow Load +i
1.) Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff
2.) Maximum allowed spacing approved by EcoFasten Solar is 48"
3.) Maximum allowed standoff capcity = 54?9 (per testing results)
.4.) Includes additional factor of safety of 1.5 for lag pullout capacity '
5,) Values based on a maximum module length of 70" _ 4
tl
6.) Based on Risk Category II (ASCE 7-10) structures less than 30 feet in height
7.) All adjustment factors are set to 1. No site specific engineering is included in this table
4
� t
www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 n
I
6
I
,.GrounDinG inFormaT1on
The rail -free Rock -It System may be used to mount and ground PV modules that comply with UL 1703, only when that specific module has been
evaluated for mounting and grounding, in compliance with the included installation instructions.
Note: Grounding lug must be visible to inspectors from the entire perimeter of the PV array. '
Multiple Use Grounding Pins sr' t
Grounding pins within the Mid -Clamp are multiple use bonding/grounding devices. Modules will need to be adjusted if the Mid -Clamps are
loosened to ensure there isnnewr+metal to'pierce into upon retightening.
` Grounding Method
r
Rock -It 2.0 Mount bonds N -S rows of modules ;
Rock -It 2.0 Coupling bonds E -W rows of modules
Array Skirt 2.0 bonds E -W along the entire array when installed
One Burndy CL50-ITN ground lug is required per PV array, limited to 300 modules placed in either portrait or landscape orientation.
BonDinG ASseMBL-Y anD BonDinG PaTH
J_
r
µ
'r
Bond Path
Bond Path
'c
i• -
j
0 Grounding lug
' gnetalry to earth
pound
,,4 r::1
„r. �; k�.
fit, -. ��•.,.,,,
�._ EquWment Grounding
-
• 1 � •l 1) Fi
• Rotk-IrMmmt
J
Conductor IEGC!-
generally to earth
d
, • Wound.
�•
" m. Ruck -It Coupling .
w Ruck -LL Coupling
J
-i
tt• - R � -
a
• RgCk.tt Mount
e Rock -It Array Skirt _
�ROCk-Il Array Skirt
..
www.ecofastensolar.com
I
ti
Integrated Bonding
+ +
r�•. �-�L �� r 'rcr � �' s
r
µ
Bond Path
•L' f
Grouodinglug
�[.t�', t� ,= { '*''� ' '.�
-Bond Path
' gnetalry to earth
pound
[
-
40 Grounding Lug +
,
Equipment Grounding
�• CanduaorlEGCi-
• Rotk-IrMmmt
ground y lu cetUt
, • Wound.
�•
" m. Ruck -It Coupling .
- _ - 8, Rock -IC Mount
e Rock -It Array Skirt _
It
..
www.ecofastensolar.com
I
ti
Integrated Bonding
+ +
r�•. �-�L �� r 'rcr � �' s
Bond Path
•L' f
Grouodinglug
�[.t�', t� ,= { '*''� ' '.�
EquiuniGrounding
' gnetalry to earth
pound
a Rock -It Coupling
• Rotk-IrMmmt
- � J
� Rock -Ir Array Skit I
info@ecofastensolar.com
<t
877-859-3947 12
THermaL ExPansion anD BonDinG
A thermal expansion gap is
required per each continuous 40'
length of modules.
Omit a coupling and leave a 2" 1
gap in the array skirt and also
between the modules at that
point.
BracKeT sPacinG
Portrait Orientation
Bond Pail)
® Grounding Lug
onVpinent Grounding
Cductor (EGq-
gerlCrally lU CLIh
glow:d
ROCk,lt Coupling
• Rock -It Mount
Rock•it Array Skirt
R
Landscape Orientation
i
32mm, 35mm & 40mm Modules: _ . Max east/west�bracket! spacing is 72"OC.
Maximum east/west bracket spacing is 48" OC. 32mm Modules: Max east/west bracket spacing is 48"OC.
Spacing may vary depending upon project specific structural requirements; i.e. high snow and wind load
areas may require lesser spacing E -W than the maximum.
sTaGGereo LaYOUT' canTILever anD oFFseT
Staggered Mounting Pointsi
.•.• ..�
O Rock -It Mount ®Rock -It Coupling Cantilever. Maximum cantilever is 1/3 bracket spacing. For portrait
orientation installations, check layout prior to installing.
The array layout instructions in this installation manual offer a
general overview of layout. Periodically, due to a variety of Offset: Offset from all roof edges depends on wind speed, snow
factors (roof obstacles, shading, etc.) other layouts are required. loads, local fire and building codes per location
www.ecofastensolar.com info@ecofastensolar.com 877-859-3947
• .I
i
13
4 Fir " �'s ,, • +`x . , �.......,� „�? � . ,,,..
t'' r. s
r�
.. r
O Rock -It Mount ®Rock -It Coupling Cantilever. Maximum cantilever is 1/3 bracket spacing. For portrait
orientation installations, check layout prior to installing.
The array layout instructions in this installation manual offer a
general overview of layout. Periodically, due to a variety of Offset: Offset from all roof edges depends on wind speed, snow
factors (roof obstacles, shading, etc.) other layouts are required. loads, local fire and building codes per location
www.ecofastensolar.com info@ecofastensolar.com 877-859-3947
• .I
i
13
ROCK -IT SCJ- STeM 2.0
EvaLuaTeD, compaTIBLe MODULes
Module Manufacturer
Model Type (X used to indicate variable lest)
Module Dimensions (mm)
Module Dimensions (in)
Trina Solar
TSM-XXX-PX05.08
1640 x 992 x 40
64.57 x 39.06 x 1.57
Canadian Solar
CS6P-XXXM
1638 x 982 x40
64.50 x 38.70 x 1.57
Canadian Solar
CS6P-XXXP
1638 x 982 x 40
64.50 x 38.70 x 1.57
Jinko Solar
JKMXXXP-60
1650 x 992 x 40
65.00 x 39.05 x 1.57
Jinko Solar
JKMXXXM-60
1650 x 992 x 40
65.00 x 39.05 x 1.57
Jinko Solar
JKMXXXPP-60
1650 x 992 x 40
65.00 x 39.05 x 1.57
Jinko Solar
JKMXXXMM-60
1650 x 992 x 40
65.00 x 39.05 x 1.57
Yingli Solar
YL2XXP-29b
1650 x 990 x 40
65.00 x 38.98 x 1.57
LG Electronics
LG300N1C-B3
1640 x 1000 x 35
64.57 x 39.37 x 1.38
LG Electronics
LG300N1 K -G4
1640 x 1000 x 40
54.57 x 39.37 x 1.57
Axilec Solar
AC-XXXM/156-60S
1640 x 992 x 40
64.57 x 39.06 x 1.57
RECOM
RCM-XXX-6MB
1640 x 992 x 35
64.60 x 39.00 x 1.38
Silfab
SLA 2XXP
1650 x 990 x 38
64.96 x 38.98 x 1.50
Solaria
PowerXT XXXR-8X
1621 x 1056 x 40
63.82 x 41.57 x 1.57
Hanwha Q Cells
Q.PRO G4 2XX'
1670 x 1000 x 32
65.70 x 39.40 x 1.26
Hanwha Q Cells
Q.PLUS BFR G4.1 XXX'
1670 x 1000 x 32
65.70 x 39.40 x 1.26
Hanwha Q Cells
Q. PRO BFR G4 XXX'
1670 x 1000 x 32
65.70 x 39.40 x 1.26
Hanwha Q Cells
Q.PRO BFR G4.1 XXX'
1670 x 1000 x 32
65.70 x 39.40 x 1.26
Hanwha Q Cells
Q.PRO BFR G4.3 XXX'
1670 x 1000 x 32
65.70 x 39.40 x 1.26
Hanwha Q Cells I
Q.PEAK G4.1 XXX'
1670 x 1000 x 32
65.70 x 39.40 x 1.26
Hanwha Q Cells
Q.PEAK BLK G4.1 XXX'
1670 x 1000 x 32
65.70 x 39.40 x 1.26
Hanwha 0 Cells
B.LINE PLUS BFR G4.1 XXX'
1670 x 1000 x 32
65.70 x 39.40 x 1.26
Hanwha Q Cells
B.LINE PRO BFR G4.1 XXX'
1670 x 1000 x 32
65.70 x 39.40 x 1.26
'Hanwha 32mm modules to be used wills special order Rock -It System components. Call for details.
• Fastest, easiest to level system on the market SIMPLE- only 4 components
• Conforms to UL 2703 First Edition North-South adjustability
• Class A Fire rating with Type 1 modules Only one tool required (1 /2" deep well socket)
• Integrated electrical bonding
Max No. of Panels
300 Modules per ground lug
Materials
300 Series Stainless Steel
6000 Series Aluminum
Max System Voltage
1000VOC
Coating
Black Andodization/Mill Finish
Class A Fire Rating
With UL1703 Type 1 Rated
Modules
ILug Specifications
Burndy CL50-1TN Ground Lug
(UL Listing #KDER E9999)
Leveling Range
3-4"
Ground Wire
Per above Lug spec
14 AWG- 4 AWG Copper
Ground Wire
Rock -it Slide -Comp 2.0 Range
Rock -It Slide -Tile 2.0 Range
3"
7"
Max Module Size
64.96"(1650mm) x
39.05"(992mm) x 2"(SOmm)
Min/Max Roof Slope
1/2:12/12:12
'Max Downforce/Uplift Rating
45 PSF
Max Anchor Spacing (35mm/40mm)
Max Anchor Spacing (32mm)
72"
48"
Rock -It Mount Load Rating
547lbs with Single 5/16" Lag
3.0 Safety Factor
Skirt Box QTY
6 units
Slide Fastening Hole
5/16"diameter
Mount Box QTY
12 units
Module Cantilever
Maximum cantilever is 1/3
bracket spacing
Rock -It Slide Box QTY
SO units
Coupling Box QTY
12 units
I Warranty
20 Year Material and
Workmanship
System marling (placed on side or underside
Codes: National Electric Code, ANSI/NEPA 70, NEC 250, NEC 690,1k, IBC
of Sock -Il Mount and (oupling)
Standards: UL 2703 First Edition, UL 1703
4'eEcoFasten Solar'
ROCK -IT SYSTEM
WG ID CODE: xXK-QQ-YM
CONFORMSTO La. °'
A
n.' EcoFasten Solar
�o
www.ecofastensolar.com
info@ecofastensolar.com 877-859-3947 14
I
PZ81
structu ra l
ENGINEERS
January 16,2017
Rillito River Solar, LLC dba EcoFasten Solar
289 Harrel Street
Morrisville, VT 05661
TEL: (877) 859-3947
Attn.: Engineering Department,
Re: Engineering Certification for the EcoFasten Rock -it System Installation Manual
This letter is to document that PZSE, Inc. -Structural Engineers has reviewed EcoFasten Rock -it System
Installation Manual published October 12, 2015 and specifically the "Loading Tables".
M SCOPE OF THE SYSTEM:
The EcoFasten Rock -it System is a solar panel support system for installing solar. photovoltaic arrays on sloped
roofs of buildings. Typically such buildings are residential with shingle or tile roofs. The number and spacing of
attachments to the roof structure can vary depending on various site specific criteria including, but not limited
to, roof slope, spacing of supporting structural members and environmental loading.
SCOPE OF OUR REVIEW:
PZSE, Inc.—Structural Engineers provided a review of the following
• Rock -it System design methodology
• Rock -it System Installation Manual
• Rock -it System Loading Tables
and has determined that. all information, data and analysis contained within the Installation Manual are based
on, and are in compliance with, the structural requirements of the following Reference Documents:
• Minimum Design Loads for Buildings and other Structures, ASCE/SEI 7-10
• International Building Code, 2015 Edition, by International Code Council, Inc. .
California Building Code, 2016 Edition, by California Building Standards Commission
• Aluminum Design Manual, 2010 & 2015 Editions, by The Aluminum Association
This letter certifies that the Ecof asten Rock -it System Installation Manual and Loading Tables are in
compliance with the. above Reference Documents..
8150 Sierra College Boulevard, Suite 150, .Roseville. CA 95661
916.961.3960 916,961.3965 www.pzse.com
4-�,` t�,1:• :d ..' 1-:.�:..�V Wr..T'_, .: t�rNj: s.
.PZ8
structural
ENGINEERS
DESIGN RESPONSIBILITY:
The Rock -it System Installation Manual is intended to be used under the responsible charge of a registered
design professional where required by the authority leaving jurisdiction. hi all cases, the user ufthe Installation
Manual has sole responsibility for the accuracy of the design and integrity of the system.
The Installation Manual does not check the capacity of the building structure to support the loads imposed on
the building by the array, such as bending strength of roof rafters spanning between supports. This requires
additional knowledge of the building and is outside the scope of the Installation Manual and our review.
If you have any questions on the above, do not hesitate to call.
Prepared By:
PZSE, Inc. - Structural Engineers
Roseville, CA
8150 Sierra College Boulevard, Suite 150, Roseville, CA 95661
916.961.3960 916.961.3965- www.pzse.com