Loading...
HomeMy WebLinkAboutB16-2610 000-000-000BUILDING ENERGY ANALYSIS REPORT' PROJECT: Henderson Garage Conversion 40 CXyote Moon Trail Oroville, CA 95914 Project Designer: Sl Design 713 ;Burnt Ranch Way Chico, CA 95973 (310) 430-8466 Report Prepared by: Max Ramirez 22189 Samson Ave. Corning, CA 96021 (530) 321-7242 SERVICES 6/6 �M NT SE� PME SER\jiCES PERMIT BUTTE COUNTY DEVELOPME REVIEWED FOR CODE COMPLIANCE BY DATE JobNumber: BUTTE 112116 -Henderson (Sl) ('0UNTY :Date: NOV 2 8 2016 DEVELOP.�4ENT 11/22/2016 SERVWES The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards. This program developed by -Ener.gySoft, LLC — www.energysdft.com. h,ergyPro 6. by EnergySoft User Number. 5733 ID: 112.116 -Henderson (5 TABLE OF CONTENTS ' Cover Page 1 Table of Contents 2 Form CF -1 R -PRF -01-E Certificate of Compliance 3 Form RMS -1 Residential Measures Summary 10 Form MF -1 R Mandatory Measures Summary 11 EnergyPro.6. by EnergySoft+ Job Number. ID: 112116 -Henderson {Sp User Number. 5733 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE_ METHOD Project Name: Residential Building _ Calculation Date/Time: 07:42, Tue, Nov 22, 2016 Calculation Description: Title 24 Analysis Input File Name: 112116 -Henderson ((SI).ribdx CF1R-PRF-01 Page 1 of 7 GENERAL INFORMATION ENERGY USE SUMMARY 01 (Project Name Residential Building 04 05 02 Calculation Description Title 24 Analysis 08 Energy Use (kTDVIft -yr) 03 Project Location 40 Cayote Moon'Trail Compliance Margin Percent Improvement 04 City Oroville 05 Standards Version Compliance 2015 .06 Zip Code 95914 07 Compliance Manager Version BEMCmpMgr 2013-4b (433) 08 Climate Zone CZ11 09 Software Version EnergyPro 6.8 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 0 12 (Project Scope Addition and/or Alteration 13 :Number of Dwelling'Units 1 14 Total Cond. Floor Area (ft2) 946. 15 Number of Zones 1 16 Slab Area '(ft2) 946 17 Number of Stories 1 18 Addition Cond. Floor Area 0 19 Natural Gas Available Yes .20 Addition Slab Area'(ft2) 0 21 Glazing Percentage (%) 12.1% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building DOES NOT require HERS Verification Registration Number: 216-A0431632A-000000000-0000 Registration Date/Time: 2016-11-22 08,06:56 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08162016-433 Report Generated at: 2016-11-22 07:43:19 ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDVIft -yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 23.72 25.37 -1.65 -7.0% Space Cooling 92.95 84.27 8.68 9.3% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 37.60 37.60 0.00 0.0'/0_ Photovoltaic Offset — 0.00 0.00 — ComplianceEnergy Total 154.27 147.24 7.03 4.6% Registration Number: 216-A0431632A-000000000-0000 Registration Date/Time: 2016-11-22 08,06:56 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08162016-433 Report Generated at: 2016-11-22 07:43:19 CERTIFICATE OF COMPLIANCE RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Building Calculation Date/Time: 07:42, Tue, Nov 22, 2016 Calculation Description: Title 24 Analysis Input File Name: 112116 -Henderson !(SI).ribdx REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. NO SPECIAL FEATURES REQUIRED CFI R -PRF -01 Page 2 of 7 HERS FEATURE SUMMARY The following is a summary,of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer 'analysis. Additional detail is provided in the building components tables below. Building -level Verifications: —None— Cooling System Verifications: —VANone — HC Distribution System Verifications: — None — Domestic Hot Water System Verifications: —None—' ENERGY DESIGN RATING This is the sum of the annual TDV energy consumption for energy use components included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an on-site renewable energy system. Reference Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDVlf2-yr)* 219.43 212.40 7.03 3.2% includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Residential Building 946 1 0 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Zone 1 Conditioned HVAC System l 946 9 DHW Sys 1 Registration Number: 216-Ao431632A-000000000-0000 Registration Date/Time: 2016-11-22 09706:56 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08162016-433 Report Generated at: 2016-11-22 07:43:19 CERTIFICATE OF COMPLIANCE RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Building Calculation Date/Time: 07:42, 'rue, Nov 22, 2016 Calculation Description: Title 24 Analysis Input File Name: 112116 -Henderson (SI).ribdx CFI R -PRF -01 Page 3 of 7 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (W) Window & Door Area (ft) Tilt (deg) Status Verified Existing Condition Front Miall -N Zone 1 R-19 Wall 0Front 0.1 261 72 90 New N/A Front Wall -Alt Zone 1 R-19 Wall 0 Front 64.5 0 90 Altered NIA Left Wall Zone 1 R-19 Wall 90 'Left 235.5 53.7 90 Altered N/A Rear Wall Zone 1 R-19 Wall 180 Back 325.5 20 90 Altered N/A Right Wall Zone 1 R-19 Wail 270 Right 235.5 28.3 90 Altered N/A Roof Zone 1 R-38 Roof Attic 946 j Altered N/A ATTIC 01 02 03 04 05 06 07 08 09 10 ' Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Status Verified Existing Condition Attic Zone 1 Attic RoofZone'l Ventilated 6 0.1 0.85 No No Existing No WINDOWS 3. 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) Height (ft) Multiplier Area (ft2) U -factor SHGC Exterior Shading Status Verified Existing Condition Window -N Front Wall -N (Front -0) — — 1 32.0 0.32 0.32 Insect Screen (default) New N/A Window -E Left Wall (Left -90) — — 1 53.7 •0.55 0.67 Insect Screen (default) Existing No Window -E 2 Right Wall (Right -270) — — 1 28.3 0.55 0.67 Insect Screen (default) Existing No DOORS 01 02 03 04 05 06 Name Side of Building Area (ft) U -factor Status Verified Existing Condition Door -N Front Wall -N 40.0 0.50 New No Door -E Rear Wall 20.0 0.50 Existing No Registration Number: 216-A0431632A-000000000-0000 Registration Date/Time: 2016-11-22 08106:56 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08162016-433 Report Generated at: 2016-11-22 07:43:19 l CERTIFICATE OF COMPLIANCE RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Building Calculation Date/Time: 07:42, Tue, Nov 22, 2016 Calculation Description- Title 24 Analysis Input File Name: 112116 -Henderson (SI).ribdx CF1 R -PRF -01 Page 4 of 7 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 09 Name Zone Total Cavity Winter Design Edge Insul. R -value Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers 124.6 None 0.8 No Existing No • Cavity/ Frame: no insul. / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofZone 1 Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Cavity/Frame: R -19/2x6 R-19 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 0.072 Exterior Finish: 3 Coat Stucco • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-9.1 /2x4 R-38 Roof Attic attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.025 Over Ceiling Joists: R-28.9 insul. SLAB FLOORS 01 02 03 04 05 06 07 08 09 Name Zone Area (W) Perimeter (ft) Edge Insul. R -value Carpeted Fraction Heated Status Verified Existing Condition Slab Zone 1 946 124.6 None 0.8 No Existing No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (011) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required — WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type • Water Heater - Number of Heaters Solar Fraction N Status Verified Existing Condition DHW Sys 1 DHW Standard DHW Heater 1 1 Annual Existing No WATER HEATERS 01 02 03 04 05 06 07 08 Name Heater Element Type Tank Type Tank Volume (gal) Energy Factor or Efficiency Input Rating Tank Exterior Insulation R -value Standby Loss (Fraction) DHW Heater 1 Natural Gas Small Storage 50 0.575 EF 40000-Btu/hr 0 0 Registration Number: 216-Ao431632A-000000000-0000 Registration Date/Time: 2016-11-22 09;06:56 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08162016-433 Report Generated at: 2016-11-22 07:43:19 CERTIFICATE OF COMPLIANCE RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Building Calculation Date/Time: 07:42, Tue, Nov 22, 2016 Calculation Description: Title 24 Analysis Input File Name: 112116 -Henderson (SI).ribdx CFI R -PRF -01 Page 5 of 7 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Point -of Use Recirculation with Manual Control Recirculation with Sensor Control DHW Sys 1 n/a n/a n/a n/a Na n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09. 10 Multi -speed Heating System Cooling System System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 11.7 13 Distribution Fan Floor Area Location Verified Existing Name System Type Name Ducted Name Ducted System System Served Status Condition HVAC Systeml Other Heating and Heating Yes Cooling Yes Air Distribution HVAC Fan 946 Existing No Existing Cooling System Component 1 Component 1 System 1 1 HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Heating Component 1 CntriFurnace - Fuel -fired central furnace 78 AFUE HVAC - COOLING SYSTEMS 01; 02 03 04 05 06 07 07 08 Efficiency 10 Multi -speed Name System Type EER SEER Zonally Controlled Compressor HERS Verification Cooling Component 1 SplitAirCond - Split air conditioning 11.7 13 No No N/A Location system Status Condition Verification Air. Distribution Ducts located in attic HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 Insulation Supply Duct Return Duct Verified Existing HERS Name Type Duct Leakage R -value Location Location Bypass Duct Status Condition Verification Air. Distribution Ducts located in attic Existing (not System 1 (Ventilated and specified) 6.0 Attic Attic None Existing No N/A, Unventilated) Registration Number: 216-A0431632A-000000000-0000 Registration Date/Time: 2016-11-22 08:06:56 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08162016-433 Report: Generated at: 2016-11-22 07:43:19 CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Building Calculation Date/Time: 07:42, Tue, Nov 22, 2016 Calculation Description;: Title 24 Analysis Input File Name: 112116 -Henderson (SI).ribdx - CF1R-PRF-01 ' Page 6 of 7 IAQ (Indoor Air Quality) FANS 01 02 03 04 65 Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 Default 01 - Not Required Registration Number: 216-Ao431632A-000000000-0000 Registration Date/Time: 2016-11-22 06:06:56 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08162016-433 HERS Provider: CaICERTS inc. Report Generated at: 2016-11-22 07:43`19 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Residential Building Calculation Date/Time: 07:42, Tue, Nov 22,-2016 Calculation Description:, Title 24 Analysis Input File Name: 112116 -Henderson (SI).ribdx CFI R -PRF -01 Page 7of7 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this'Certifcate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Max Ramirez' LW. LRamirez Company: Signature Date: Golden Sun Designs 2016-11-22 08:06:56. Address: CEA/HERS Certification Identification (If applicable): 22189 Samson Ave N/A City/State/Zip: Phone: Corning, CA 96021, 530-321-7242 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of:the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features: and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. - 3. ' The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Max Ramirez �� /� LW. LRamirez Company: Date Signed: Golden Sun Designs 2016-11-22 08:06:56 - Address: License: ` 22189 Samson Ave N/A City/State/Zip: Phone: Coming, CA 96021 530-321-7242 Digitally signed by WCERTS. This digitatsignature is provided in order to secure the content of this registered document and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-A0431632A-000000000-0000 Registration Date/Time: 2016-11-22 08:06:56 CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-08162016-433 HERS Provider: CaICERTS inc. Report Generated at: 2016-11-22 07:43:19 RESIDENTIAL MEASURES SUMMARY RMS -1 Project Name Henderson Garage Conversion Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration 11112212016 Date Project Address 40 Cayote Moon Trail Oroville California Energy Climate Zone CA Climate Zone 11 Total Cond. Floor Area 946 Addition 0 # of Units 1 INSULATION Construction Type Area Cavi (ftz Special Features Status Wall Wood Framed R 19 189 New Door Opaque Door - no insulation 40 New Wall Wood Framed R 19 759 Altered Door Opaque Door - no insulation 20 Existing Roof Wood Framed Attic R 38 946 Altered Slab Unheated Slab -on -Grade - no insulation 946 Perim = 125' Existing FENESTRATION I Total Area: 114 Glazing Percentage: 12.1 % New/Altered Average U -Factor. 0.32 Orientation Area(ft) U -Fac SHGC Overhang. Sidefins Exterior Shades Status Front (N) 32.0 0.320 0.32 none none Bug Screen New Left (E) 53.7 0.550 0.67 none none Bug Screen Existing Right (110 28.3 0.550 0.67 none none Bug Screen Existing HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat' Status 1 Central Furnace 78% AFUE Split Air Conditioner 13.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC System Ducted Ducted Attic 6.0 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnemvPro 6. by EnemySoft User Number. • 5733 ID: 112116 -Henderson 5 Pae 10 of 14 2013 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. Exceptions may apply. Review the respective code section for more informntinn Building Envelope Measures: §I 10.6(a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. § 110.6(a)5: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of §10-111 (a). § 110.7: Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed § 110.8(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R. § 110.8(i): The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 110.8(i) when the installation of a cool roof is specified on the CFI R. § 110.80): A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFI R. Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a §150.0(a): rafter roof alteration. Attic access doors shall. have permanently attached insulation using adhesive or mechanical fasteners. The attic access shall be gasketed to prevent air leakage. § 150.0(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -value. §150.0(c): Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U - factor). §150.0(d): Minimum R -I9 insulation in raised wood -frame floor or 0.037 maximum U -factor. §150.0(g)l: In Climate Zones 14 and 16 a Class 1I vapor retarder shall be installed on the conditioned space side of all insulation in all exterior walls, vented attics and unvented attics with air -permeable insulation. § 150.0(g)2: In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class 11 vapor retarder. In a building having a controlled ventilation crawl space, a Class 1 or Class II vapor retarder shall be placed over the earth floor of § 150.0(g)3: the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section 150.0(d). §150.00): Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.30/c; have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration; and when installed as part of a heated slab floor meets the requirements of § 110.8( . §150.0(q): Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U - factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58. Fireplaces, Decorative Gas Appliances and Gas Log Measures: § 150.0(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150.0(e)1B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is e ui"p ed with a readily accessible, operable, and tight -fitting damper or a combustion -air control device. § 150.0(e)1C: Masonry or factory -built fireplaces have a flue damper with a readily accessible control. §150.0(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110.0-§110.3: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission. §110.3(c)5: Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli- § 110.5: ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool ands a heaters. § 150.0(h)1: Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified in §1.50.0(h)2. § 150.0(h)3A: Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any dryer vent. § 150.0(i): Heating systems are equipped with thermostats that meet the setback requirements of § 110.2(c). §150.00)1A: Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. § 150.00)1B: Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage tank, all piping with a nominal diameter of. 3/4 inch or larger, all. piping associated with a domestic hot water recirculation system § 150.00)2A: regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3- A. V, 50.00)2B: All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed a and insulation. 2013 Low -Rise Residential Mandatory Measures Summary §150.00)2C: Pipe for cooling system lines shall be insulated as specified in §150.00)2A. Piping insulation for steam and hydronic heating stems or hot water systems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A. § 150.00)3: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For § 150.00)3A: example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or painted with coating that is water retardant and provides shielding from solar radiation that degrades the material. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I §150.00)3B: or Class 11 vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class 1 or Class Tl vapor retarder. Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the §150.0(n)l: space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating loops serving multiple dwelling units shall meet the requirements of § 110.3(c)5. § 150.0(n)3: Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SACC) orby a testing enc a roved by the Executive Director. Ducts and Fans Measures: All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0, §603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC §605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed §150.0(m)]: with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181., UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If` mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. Factory=Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints §150.0(m)2: and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. §150.0(m)3-6: Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other requirements specified for duct construction; duct insulation. R -value ratings; duct insulation thickness; and duct labeling. §150.0(m)7: All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers except combustion inlet and outlet air openings and elevator shaft vents. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not § 150.0(m)9: limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. §150.0(m)10: Flexible ducts cannot have porous inner cores. When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be § 150.0(m)11: sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference ___Residential_ Appendix RA3. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal §150.0(m)12: conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of §150.0(m)12. Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The § 150.0(m)13: space conditioning system roust also demonstrate airflow 2:350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy:5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Zonally controlled central forced air cooliiig sy§Echis shall lie capable of §ihiiiltaiieoiisly 8elivering, in every" zoiW control mode, §150:0(m)15: an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of >_ 350 CFM per ton of nominal cooling capacity, and operating at an air -handling unit fan efficacy of:S 0.58 W/CFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of § 150.0(0): central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the Whole Building Ventilation. §150.0(o)IA: Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3. Pool and Spa Heating Systems and Equipment Measures: Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency § 110.4(a): Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating. ,, 2013 Low -Rise Residential Mandatory Measures Summary § I 10.4(b) 1: Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction and return lines, or built-up connections for future solar heating. § 110.4(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. § 110.4(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro- grammed to run only during off-peak electric demand periods. § 110.5: Natural gas pool and spa heaters shall not have a continuous burning pilot light. §150.0(p): Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements. Lighting Measures: § 110.9: All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9. §150.0(k)IA: Installed luminaires shall be classified as`high-efficacy or low -efficacy for compliance with §I50.0(k) in accordance with TABLE 150.0-A or TABLE 150.0-B, as applicable. § 150.0(k)1B: When a high efficacy and low efficacy lighting system are combined. in a single luminaire, each system shall separately comply with the applicable provisions of § 150.0(k). The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with § 150.0(k)1C: § 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180 watts of low efficacy lighting r electrical box. § 150.0(k)1D: Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. Permanently installed night lights and night fights integral to installed luminaires or exhaust fans shall be rated to consume no § 150.0(k)IE: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with. § 1.30.0(c). Night lights do not need to be controlled by vacancy sensors. §150.0(k)IF: Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable requirements of §150.0(k). § 150.0(k)2A: High efficacy luminaires must be switched separately from .low efficacy luminaires. § 150.0(k)2B: Exhaust fans shall be switched separately from lighting systems. § 150.0(k)2C: Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § I50.0(k)2D: Controls and equipment are installed in accordance with manufacturer's instructions. § 150.0(k)2E: No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § I50.0(k). § 150.0(k)2F: Lighting controls comply with applicable requirements of § 110.9. An Energy Management Control System (FMCS) may be used to comply with dimmer requirements if. it functions as a dimmer § 150.0(k)2G: according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5; and all other requirements in §150.0(k)2. An Energy Management Control System (FMCS) may be used to comply with vacancy sensor requirements of § 150.0(k) if. it § 150.0(k)2H: functions as a vacancy sensor according to §110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements of § 130.5; and all other requirements in § 150.0(k)2. § 150.0(k)2I: A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the functionalityof a dimmer accordingto §110.9, and complies with all other applicable requirements in §150.0(k)2. § 150.0(k)3A: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall. be high efficacy. Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only § 150.0(k)3B: the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are considered kitchen lighting if they are not separately switched from kitchen lighting. § 150.0(k)4: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. § 150.0(k)5: A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom shall be high efficacy or controlled by vacancy sensors. §I50.0(k)6: Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and controlled by vacancy sensors. §150.0(k)7: Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy, or shall be controlled by either dimmers or vacancy sensors. Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing § 150.0(k)8: and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and allow ballast maintenance and replacement without requiring cutting holes in the ceiling. For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with §150.0(k), the ballasts shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9. For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements: i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of items ii or iii below; and §150.0(k)9A: ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically reactivates the motion sensor within 6 hours; and iii. Controlled by one of the following methods: 2013 Low -Rise Residential Mandatory Measures Summary a. Photocontrol not having an override or bypass switch that disables the photocontrol; or b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is programmed to automatically turn the outdoor lighting OFF during daylight hours; or c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the requirements for an EMCS in §130.5; does not have anoverride or bypass switch that allows the luminaire to be always ON; and, is programmed to automatically turn the outdoor lighting OFF during daylight hours. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the §150.0(k)9B: following requirements: i. Shall comply with § 150.0(k)9A; or ii. Shall comply with theapplicable requirements in 110.9, §130.0, §130.2, §130.4, §140.7 and §141.0. § 150.0(k)9C: For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § 150.0(k)9B or 150.0(k)9D shall comply with the applicable requirements in § 110.9, 130.0, 130.2, 130.4,140.7 and 141.0. § 150.0(k)9D: Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0. §150.0(k)10: Internally illuminated address signs shall comply with §140.8; or shall consume no more than 5 watts of power as determined according to § 130.0(c). §150.0(k)ll: _ Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for nonresidential garages in §110.9, $130.0, § 130. 1, §1.30.4, § 140.6, and § 141.0. In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of § 150.0(k)12A: the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or controlled by an occupant sensor. In a low-rise multifamily residential building where the total interior. common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building shall: § 150.0(k)12B: i. Comply with the applicable requirements in § 110.9, § 130.0, § 130. 1, § 140.6 and § 141.0; and ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of ingress and egress. Solar Ready Buildings: Single family residences located in subdivisions with ten or more single family residences and where the application for a §110.10(a)l:, tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014, shall comply with therequirements of § 110.10 through $110.10(e). §110.10(a)2: Low-rise multi -family buildings shall comply with the requirements of §110. 1 0(b) through § 1.10.1.0(d). The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for §l 10.10(b)l: buildings with roof areas greater than 10,000 square feet. For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. § 110.10(b)2: All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be located in the solar zone. Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice § 110.10(b)3B: the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane. § 110.10(b)4: For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly indicated on the construction documents. The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit § 110.10(c): from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating system. § 110.10(d): A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through § 110.10(c) shall be provided to the occupant. §110.10(e)l: The main electrical service panel shall have a minimum busbar rating of 200 amps. The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a § 110.10(e)2: future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or main circuit location, and permanently marked as "For Future Solar Electric".