Loading...
HomeMy WebLinkAboutB16-2621 000-000-000383 Rio Lindo Ave, Chico, CA 95926 p, (530) 592-4407 www.summitchico.com Structural Calculations For: Client: Tim Duntsch - North Valley Building Systems Project: Lundberg Family Farms - Temporary Trailers Deck _Address: BUTTE 5311 Midway, Richvale, CA COUNTY NOV 2 9 2016 OQ�ypFES Ip���` DEVELOPMENT SERVICES PERM11' # * EuiT CE .--... EXP. 06/30/20 B N7 Y DEVELOPMENT SERVICES S'T civ C CO ®D FOR �TFIJrCALF !'"! �� X70 -BY-� ti �1"1 Ili Note: Summit Structural Design (SSD) is not responsible for on-site inspection to assure compliance with the standards, sizes, materials, or workmanship specified herein. SSD is not responsible for any structural element or system not specifically noted in this set of specifications/calculations unless authorized in writing by SSD. Workmanship shall be of the highest quality and in all cases shall follow accepted construction practice, the latest edition of the California Building Code, and local building department standards. STRUCTURAL NOTES 1. GENERAL A) ALL WORK SHALL CONFORM TO THE 2013 CBC AND ALL APPLICABLE LOCAL CODES. B) THE ENGINEER (SUMMIT STRUCTURAL DESIGN) IS RESPONSIBLE FOR THE STRUCTURAL ITEMS IN THE PLANS ONLY, THE GENERAL CONTRACTOR SHALL VERIFY THAT ALL CONSTRUCTION IS IN FULLAGREEMENT WITH THE LATEST, BUILDING DEPARTMENT APPROVED, STRUCTURAL DRAWINGS. SHOULD ANY CHANGES BE MADE FROM THE DESIGN AS SPECIFIED IN THESE CALCULATIONS WITHOUTTHE WRITTEN APPROVAL FROM THE ENGINEER, THEN THE ENGINEER WILL ASSUME NO RESPONSIBILITY FOR ANY ELEMENT OR SYSTEM OF THE STRUCTURE, C) THE DRAWINGS AND CALCULATIONS REPRESENTTHE FINISHED STRUCTURE, AND, UNLESS SPECIFICALLY NOTED OTHERWISE, DO NOT SHOW THE METHOD OF CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR THE METHOD OF CONSTRUCTION, AND SHALL PROVIDE ALL; MEASURES NECESSARY TO PROTECT THE PUBLIC, CONSTRUCTION WORKERS, AND THE STRUCTURE DURING CONSTRUCTION, SUCH MEASURES SHALL INCLUDE FORMING, SHORING, BRACING, SCAFFOLDING, ETCETERA, 0) IF A PARTICULAR FEATURE OF CONSTRUCTION IS NOT FULLY SHOWN ON THE DRAWINGS OR IN THE CALCULATIONS, THEN IT SHALL BE CONSTRUCTED IN THE SAME CHARACTER AS SIMILAR CONDITIONS THAT ARE SHOWN ON THE DESIGN DOCUMENTS, E) ANY CONDITIONS NOTED AS EXISTING MUST BE FIELD VERIFIED BY THE CONTRACTOR, AND ANY DISCREPANCIES MUST BE BROUGHT TO THE ATTENTION OF THE ENGINEER WITHOUT PROCEEDING WITH CONSTRUCTION PRIOR TO THE REVIEW OF THE ENGINEER. F) ALL WATER PROOFING AND FLASHING (ROOFS, FOUNDATIONS, GARAGE FLOORS, ETC.. ,) IS THE RESPONSIBILITY OF THE CONTRACTOR OR OWNER. 2. SITE WORK / FOUNDATIONS A) ASSUMED MAXIMUM SOIL BEARING =1,500 PSF PER CBC TABLE 1804.2. B) BUILDING SITE IS ASSUMED TO BE DRAINED AND FREE OF CLAY OR EXPANSIVE SOIL. ENGINEER HAS NOT MADE A GEOTECHNICAL REVIEW OF SITE, ANY OTHER CONDITIONS ENCOUNTERED MUST BE BROUGHT TO THE ATTENTION OF THE ENGINEER. C) THESE CALCULATIONS ASSUME STABLE, UNDISTURBED SOILS AND LEVEL OR STEPPED FOOTINGS. ANY OTHER CONDITIONS SHOULD BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO THE CONSTRUCTION OF THE FOUNDATIONS, D) ALL FOOTINGS INCLUDING RETAINING WALL FOOTINGS, SPREAD FOOTINGS, WALL FOOTINGS, AND GRADE BEAMS SHALL BEAR ON UNDISTURBED SOIL WITH AFOOTING DEPTH BELOW FROSTLINE. E) BOTTOM OF ALL FOUNDATION TRENCHES SHALL BE CLEAN AND LEVEL. F) ALL FINISHED GRADE SHALL SLOPE AT A MINIMUM SLOPE OF 5% AWAY FROM ALL FOUNDATIONS A MINIMUM OF 10 FEET HORIZONTAL. G) FOUNDATIONS SHALL NOT BE SCALED FROM PLAN OR DETAIL DRAWINGS, H) FILL MATERIAL SHALL BE FREE FROM DEBRIS, VEGETATION, AND OTHER FOREIGN SUBSTANCES, AND SHALL BE COMPACTED A MINIMUM OF 90%, 1) USE 4" DIAMETER PERFORATED PIPE SUB -DRAIN BEHIND ALL RETAINING WALLS. SLOPE PIPE TO DRAIN TO DAYLIGHT. J) FOR FOOTINGS PLACED ON OR ADJACENT TO SLOPES, A GEOTECHNICAL ENGINEER MUST APPROVE FOOTING PLACEMENTS IN VIOLATION OF FIGURE 1808.7.1 OF THE 2013 CBC, THIS ENGINEER SHALL NOT BE LIABLE FOR ANY FOUNDATION NOT IN STRICT CONFORMANCE TO SECTION 1808 OF THE 2013 CBC. 4. CONCRETE / REINFORCING A) CONCRETE SHALL HAVE A MINIMUM 28 DAY STRENGTH OF 3,000 PSI U.N.O. (DESIGN BASED ON 2,500 PSI) G) ALL CEMENT USED SHALL CONFORM TO ASTM C-150 AND SHALL BE TYPE 11 OR TYPE III LOW ALKALI. D) AGGREGATE SHALL CONFORM TO ASTM C-33 AND SHALL NOT CONTAIN MATERIALS THAT ARE ALKALI REACTIVE AS DETERMINED BY ASTM C-227,289, AND 295, IF TEST DATA IS UNAVAILABLE IN REGARDS TO ALKALI REACTIVE MATERIALS, PROVIDE CEMENT WITH A MAXIMUM ALKALI CONTENT LESS THAN OAS% BY WEIGHT. E) CONCRETE EXPOSED TO FREEZING OR THAWING SHALL BE PROTECTED IN ACCORDANCE TO THE LATEST EDITION OF ACI 318. F) SLABS ON GRADE SHALL BE PER THE CONTRACTOR. SUMMIT STRUCTURAL DESIGN RECOMMENDS THE FOLLOWING AS A SUITABLE SLAB -ON -GRADE: AT GARAGE SLABS, USE 4" THICK S.O.G. WITH 93 BARS AT 15" O,C. EACH WAY ABOVE MID -DEPTH OF SLAB, OVER MOISTURE BARRIER, OVER 4" AGGREGATE BASE. USE 3-1/2' SLAB WITH #3 AT 15" E.W. ABOVE MID -DEPTH OF SLAB, OR 6X6 WWF ABOVE MID -DEPTH OF SLAB WITH SAME SUB -SLAB BUILDUP AT ALL OTHER AREAS. G) SAW-CUTTOP %' OF SLAB FOR CRACK CONTROL AT INTERVALS NOT TO EXCEED 16'-0" WHERE SLAB IS REINFORCED, SAW CUT AT INTERVALS NOT TO EXCEED 7'-0" WHERE SLAB IS UN -REINFORCED. 1) REINFORCEMENT COVER SHALL BE AS FOLLOWS: CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO SOIL: 3" CONCRETE WITH SOIL OR WEATHER EXPOSURE: #5 BARS AND SMALLER: 1 ?' #6 BARS AND LARGER: 2" CONCRETE WITHOUT SOIL OR WEATHER EXPOSURE: %" J) REINFORCEMENT SHALL BE GRADE 60 PER ASTM A615 U.N.O. LAP BOTTOM BARS 60 BAR DIAMETERS U,N.O. AND LAP TOP BARS, PLACED ABOVE 12" OF CONCRETE OR MORE, 80 BAR DIAMETERS U.N.O. K) #5 AND LARGER REBAR SHALL NOT BE RE-BENT. L) ALL. REINFORCING STEEL AND ANCHOR BOLTS SHALL BE ACCURATELY LOCATED AND ADEQUATELY SECURED IN POSITION BEFORE AND DURING CONCRETE PLACEMENT. T 2 6. FRAMING/LUMBER 6-1 MATERIALS: A.) SHEATHING: 1. ROOF SHEATHING: %' APA RATED 32/,16 EXPOSURE 1, STRUCTURAL SHEATHING WITH FACE GRAIN PERPENDICULAR TO FRAMING, STAGGER PANELS ANDNAIL WITH Bd AT 6" Q.C. EDGE, 12" O.C. FIELD U.N.O. PROVIDE 1/8" GAP AT ALL PANEL EDGES U.N.O. BY PANEL MANUFACTURER. 2, FLOOR SHEATHING: Y0 APA RATED 48/24 WITH FACE GRAIN PERPENDICULAR TO FRAMING, STAGGER PANELS AND NAIL WITH 10d AT 6" O.C, EDGE 10" O.0 FIELD, GLUE AND NAIL TO ALL SUPPORTS. PROVIDE 1/8" GAP AT ALL PANEL EDGES U.N,O. BY PANEL MANUFACTURER, 3. WALLSHEATHING: SEE PLANS 4. ANY SHEATHING WITH EXTERIOR EXPOSURE SHALL BE OF EXTERIOR TYPE. B.) GLUE -LAMS: GLUE -LAMS SHALL BE 24F -V4 U.N.O. WITH A CAMBER OF R=160(y U.N.O. GLUE -LAMS EXPOSED TO WEATHER MUST BE RATED FOR EXTERIOR USE BY THE MANUFACTURER, FLASHING AND WATERPROOFING OF EXPOSED ENDS SHALL BE PROVIDED BY THE CONTRACTOR TO PREVENT DECAY, GLUED LAMINATED FABRICATION SHALL BE PERFORMED IN AN APPROVED FABRICATOR'S SHOP IN ACCORDANCE WITH CBC 2303.1.3, AITCA190.1 AND ASTM D 3737. BEAM INSPECTION CERTIFICATES SHALL BE SUBMITTED TO THE FIELD INSPECTOR PRIOR TO COMPLETION OF FRAME INSPECTION IN ACCORDANCE WITH CBC 1704,2. C,) MICRO -LAMS: MICRO -LAMS (LAMINATED VENEER LUMBER) SHALL HAVE FB = 3100 PSI & FV = 285 PSI MIN., AND SHALL BE MANUFACTURED, APPROVED AND IDENTIFIED AS PER NER-481 C2.) PARALAMS: PSL'S (PARALLEL STRAND LUMBER) SHALL HAVE FB =3100 PSI & FV= 290 PSI MIN., AND SHALL BE MANUFACTURED, APPROVED AND IDENTIFIED AS PER NER-481 D.) SILL PLATES: SILL PLATES SHALL BE PRESSURE TREATED DOUGLAS FIR WITH 1/2" DIAMETER ANCHOR BOLTS AND 3 X 3" X,229" THICK PLATE WASHERS LOCATED AT V-0" O.C. MAX. WITH ONE BOLT LOCATED V-0" MAXIMUM AND (7) BOLT DIAMETERS MINIMUM FROM EACH END OF EACH PIECE, THE EDGE OF THE SILL PLATE WASHER SHALL BE LOCATED X" MAXIMUM FROM FACE OF WALL SHEATHING. AT SHEAR WALL LOCATIONS, SILLS SHALL BE 3X MATERIAL UNO PER PLANS AND DETAILS. E.) FRAMING LUMBER: ALL FRAMING LUMBER SHALL BE DOUGLAS FIR LARCH AS GRADED BY THE W.W.P.A, OR W.C.L.I.B. AND SHALL HAVE A MOISTURE CONTENT LESS THAN 19%, U.N.O. 1. STUDS SHALL BE STUD GRADE OR BETTER, 2. ALL POSTS SHALL BE DR#1 U.N,O. 3. 2X AND 3X RAFTERS SHALL BE DF -L #2 U.N.O. 4. 2X JOISTS SHALL BE DF -L #2 U.N.O. 5. CONCEALED BEAMS SHALL BE DF -L #2 6. EXPOSED BEAMS SHALL BE DF -L #1 APPEARANCE GRADE FREE OF HEART CENTERS (4X6 AND LARGER) F,) NAILS: ALL NAILS SHALL BE COMMON U.N.O. WHERE EXPOSEDTO WEATHER OR WITHIN 18" OF FOUNDATION, NAILS SHALL BE HOT DIPPED GALVANIZED. G.) BOLTS AND LAG SCREWS: BOLTS AND LAG SCREWS SHALL BE ASTM A-307 U.N.O. AND PROVIDED NEW AND WITHOUT EXCESSIVE RUST, BOLTS EXPOSED TO WEATHER SHALL BE GALVANIZED. H.) ALL HARDWARE CALLED SHALL BE SIMPSON STRONG -TIE CO., OR ENGINEER APPROVED EQUIVALENT, INSTALLED PER MANUFACTURER'S RECOMMENDATIONS WITH ALL HOLES FILLED WITH RECOMMENDED FASTENERS h) ALL METAL FASTENERS IN CONTACT WITH PRESSURE TREATED WOOD SHALL BE STAINLESS STEEL OR OTHERWISE CERTIFIED BY THE MANUFACTURER TO RESIST CORROSION CAUSED BY THE SPECIFIC TREATMENT APPLIED TO WOOD, J.) MANUFACTURED "I" JOISTS, MANUFACTURED I JOISTS (SUCH AS TRUSS JOISTS) SHALL BE INSTALLED PER THE MANUFACTURES RECOMMENDATIONS USING A DEFLECTION LIMIT OF L/480 U.N.O, USE A MANUFACTURED 1-1/4" RIM BOARD (SUCH AS TIMBER STRAND) WITH ALL "I" JOISTS. USE A DOUBLE RIM OR 1 V/+ LVL RIM AT ALL LOCATIONS WHERE LEDGERS ARE USED (SUCH AS DECK LEDGERS). -2 GENERAL FRAMING A.) MINIMUM NAILING: MINIMUM NAILING SHALL BE PER 2013 CBC TABLE 2304,9.1. B,) LARGER MEMBERS: ALL FRAMING MEMBERS SPECIFIED IN THESE CALCULATIONS ARE MINIMUMS; LARGER MEMBERS MAY BE SUBSTITUTED AT CONTRACTOR'S OPTION. C.) SHRINKAGE: CARE SHALL BE TAKEN TO ALLOW FOR EFFECTS OF SHRINKAGE, WHICH COULD CAUSE SETTLEMENT OF ROOF AND OR FLOORS AND COULD LEAD TO FAILURE OF ASSOCIATED FRAMING MEMBERS, THE CONTRACTOR SHALL TAKE ALL MEASURES NECESSARY TO PROTECT FRAMING FROM THE EFFECTS OF SHRINKAGE. 6-3 BEAM FRAMING A.) BUILT UP BEAMS: ALL BUILT UP, LAMINATED DOUBLE OR MULTIPLE 2X JOISTS AND BEAMS SHALL BE NAILED TOGETHER WITH 16d NAILS AT 6" O.C., T&B U.N.O. B.) DOUBLE JOISTS: PROVIDE DOUBLE FLOOR JOISTS UNDER PARTITION WALLS RUNNING PARALLEL TO JOIST SPAN AND UNDER ALL LOCATIONS WHERE TUBS MAY BE LOCATED, ADEQUATE SUPPORT SHALL BE PROVIDED FOR ALL OTHER EQUIPMENT OR FURNISHINGS WHICH MAY NOT BE SHOWN ON THE STRUCTURAL DRAWINGS INCLUDING BUT NOT LIMITED TO: HOT WATER HEATER, STOVE, REFRIGERATOR, OVEN, FIRE PLACE ENCLOSURES, WOOD BURNING STOVE, ETC... C.) BLOCKING: PROVIDE SOLID BLOCKING IN JOIST FRAMING ABOVE ALL SUPPORTS AND MIDSPAN OF JOISTS SPANNING GREATER THAN 10'-O" I 6.4 POSTS/TRIMMERS A.) SUPPORT: SUPPORT ALL UPPER LEVEL POSTS AND TRIMMERS IN LOWER LEVELS WITH EQUIVALENT FRAMING AND BLOCK OR OTHERWISE FRAME POSTS THROUGH FLOOR SYSTEMS. B.) WHERE POSTS WITH COLUMN CAPS OR BEARING PLATES ARE SPECIFIED, THE LOAD IS TO BE TRANSFERRED TO THE FOUNDATION BY VERTICAL GRAIN ONLY, U,WO. 6.5 WALL FRAMING A.) DOUBLE TOP PLATE SPLICES: SPLICES AND JOINTS IN DOUBLE TOP PLATE OF STUD BEARING WALLSHALL OCCUR AT THE CENTER LINE OF SUPPORTING STUD. TOP PLATE SPLICES OF STUD WALLS SHALL BE 48" LONG WITH (12) 16d SINKERS EACH SIDE OF EACH SPLICE U.N.O. WHERE SPLICE IS INTERRUPTED, USEST6224 STRAP U.N.O. B.) FIRE BLOCKS; FIRE BLOCK STUD WALLS AT MID -HEIGHT WHERE STUD LENGTH EXCEEDS 10'-0" C.) MIS -PLACED ANCHOR BOLTS: WHERE ANCHOR BOLTS HAVE BEEN INCORRECTLY PLACED, USE HILT] QWIK-BOLT (I OF SAME DIAMETER WITH EMBEDMENT IN CONCRETE AND INSTALLATION PER MANUFACTURERS RECOMMENDATIONS AND CURRENT ICC REPORT. D.) NOTCHED OR CUTSTUDS: NOTCHED AND/OR CUT STUDS TO CLEAR ANCHOR BOLTS ARE NOT ALLOWED. STUDS SHALL HAVE FULL BEARING TO THE FOUNDATION PLATE. E.) LET -IN BRACES: LET IN BRACES SHALL NOT BE USED FOR TEMPORARY BRACING ON ANY WALL FRAME, STEEL STRAPS WHICH DO NOT REQUIRE THE CUTTING OF STUDS ARE AN ACCEPTABLE ALTERNATIVE. F.) SEE NOTE 6.1 D. FOR SILLAND ANCHOR BOLT SPECIFICATIONS. G.) WALL FRAMING RECEIVING NAILING AT 3" O.C. OR LESS SHALL BE SX NOMINAL UNO PER PLANS AND DETAILS. 6-6 CONNECTIONS A.) HOLES FOR THROUGH BOLTS SHALL BE DRILLED 1/16" OVERSIZE, B.) ALL BOLTS, NUTS, AND LAG SCREWS SHALL BE PROVIDED WITH FLAT OR MALLEABLE WASHERS WHERE BEARING AGAINST WOOD. C.) ALL BOLTS AND LAG SCREWS SHALL BE TIGHTENED UPON INSTALLATION AND RE -TIGHTENED BEFORE CLOSING IN OR AT COMPLETION OF JOB, D:) LAG SCREWS SHALL BE SCREWED, NOT DRIVEN, INTO PLACE. E.) FASTENERS IN PRESERVATIVE OR FIRE RETARDANT TREATED WOOD SHALL BE HOT DIPPED GALVANIZED, 9. DESIGN LOADS A) ALL DESIGN LOADS ARE PER CBC CHAPTER 16, DIVISIONS I, II, III, AND IV U.N.O. B) FLOOR DEAD LOAD: 10 PSF FLOOR LIVE LOAD; 100 PSF C) SEISMIC ZONE: 0 D) WIND SPEED: 110 MPH EXP C Summit Structural Design Cantilever Retaining Mall Design Project: Comments: Date: 10/5/2016 Input Width Wall 7.6 in 2.17 Footing 2.00 ft 1.53 Key 0.0 in Weight xbor Ind Vertical Load at top of wall (k) 0.0 Moment at top of wall (k -ft) 0.0 Add'I Hor. Load 1 (k) 0.000 Add`l Nor, Load 2 (k) 0.0 Add`l Hor. Load 3 (k) 0.0 Add'I Hor. Load 4 (k) 0.0 Add'l Hor. Load 5 (k) 0.0 Uniform Surcharge (psf) 0.0 Active Soil -Eq. Fluid Wt. (pcf) 45 Passive Soil - Eq. Fluid (pcf) 250 Passive Soil - Uniform (psf) 0.0 Sliding Friction Coeff. 0.35 VUI UI Unit 2.17 Sliding Safety Factor 1.53 Toe Soil Bearing Weight xbor ybar L•fidghl Rth (pcf) ft ft 2.7 ft 150 1.00 1.04 18,0 in 150 1.00 -0.75 0.0 in 0 0.00 -1.50 kLdlgbt xbar. yber 1.00 2.67 1.00 2.67 0.0 ft 0.00 0.0 It -- 0.00 0.0 It - 0.00 0.0 ft _- 0.00 0.0 ft .. 0.00 0.0 ft -- 0.00 2.7 ft Wt: 110 pcf 0.0 ft 0.0 ft VUI UI overturning Safety Factor 2.17 Sliding Safety Factor 1.53 Toe Soil Bearing 0.86 ksf Heel Soil Bearing 0.05 ksf Soil Pressure Length 2.00 ft Moments • - Wall Mom. @ Base of Wall 0.14 kip - ft Toe Moment 0.12 kip - it Heel Moment 0.12 kip ft (Positive = Right hand Rule) Overturning Moment Righting Moment Sliding Force Resisting Force ,11 0.54 k -ft 1.18 k4t 391 # 598 # LSur ----a H abv TOF TOF lfa 4 .... , ..0„22 Equivalent y o.c.bar spacing Summit Structural Design Bar Size Bar Dia Bar Area Retaining Wali Design ' 8 1 9 12 16 18 3 0.375 Flexure Design based on ULT Loads [ Residential, No Insp:7 Wail Thicknessi8lin ....... 4 ......I.. 0 5 Restrained? :.:...n 20 0.3 9 iV UDDly. R0inf . 0.79 QQoret� Retalni.ng WaiLl..oasi� M" 0.32 k -ft Mu 0.24 k -ft EQ Point Load lbs/ft . ,.. 1 23 1 53 6 Apply at 0.6 H d 4 in d 4 in EQ PSF psf b 16 in b 12 in Pa 45 pcf tfm 1,5 ksl f'c 2.5 ksi Height Retained 2,67 ft fy 60 ksi fy 60 ksi Soil Moment 143 ft -lb . 3 93 9 1 128 EQ Moment 0 ft -Ib rho b 0.011 rho b 0,018 M„ 243 ft -lb A, max 0.342 In A2 A, max 0.641 in^2 2.53 ...1 1.33 Ag regd 0.021 In A2 A$ regd 0.014 In ^2 Min AW (per code) 0.192 in ^2 ........ 1 56 3 12 ..., ...3,80 4 68 Min Av (per code) 0.1152 In^2 14 1.693 2 25 2 25 Number of gars Bar Size .Bar Dia Bar Area 1 2 3 4 5 ....... 16.00 2U.00 30 2 25 375 0 11 0.11 2.257 .................. 4.00 8.00 ....,,.3 6.'0'0 5.33 j Equivalent area for o.c.bar spacing of Bar Size Bar Dia Bar Area 6 1 ' 8 1 9 12 16 18 3 0.375 0.11 ...,0:33 ............. a.,`�`�......,....... 0,55 ....... 4 ......I.. 0 5 O:Q7 :.:...n 20 0.3 9 ...,.......05 9 . 0.79 ......... 0 9$ 5 0 625 .0.20 0 31 , 0.3. ................... ......... 5 0 92 ..........,. . ,.. 1 23 1 53 6 0.75 ........ 0.44 , .. 0.44 ...............1 ..............1. 3 .... 1 77 , 7 0 875 ............... ..............0.3 0 60 ......., .....20 .......$0 ..,.......2..41 3.01 ......... ......,., ..............0.60............ 0 79 0 79 ............... . . 67 .............. 36 ....... x..1.......... . 3 93 9 1 128 1 00 1 00 2 . . .. 00 .. .. 00 ......... 5 QO 9 1 27 1 27 1 27 2.53 ...1 1.33 ......,. 5 07 ,.,...... 6.33 .....................10 11 1 41 1 56 ........ 1 56 3 12 ..., ...3,80 4 68 . s 25 ..... 7 87 14 1.693 2 25 2 25 4 50 6 75 9 Q0 11,26 .........i 8 2.257 .........4 00 4.00 8.00 ..... , 12,00 ....... 16.00 2U.00 Equivalent area for o.c.bar spacing of Bar Size Bar Dia Bar Area 6 1 ' 8 1 9 12 16 18 3 0.375 0.11 0 22 0.17 0.15 0 11 0 08 O:Q7 ........................... 4 ................. 0.5 0.20 .......... 4.26 .., ..,....0 20 ...... 0 15 0 13 ................... ......... 5 0 625 0 31 .. ...........0:39. 0 61 , ....,....0..29 0 45 ..,.,.. .......:.....0..41 , ., .., .0..31.......: , ..p. 23 ....... 0 20 ...........6 6 .......... ,.75. 0 75 ......... 3. `�`i 0 88 00 ,..... ,. 0..'0 ............4: ....... 0 33 ...... 0 29 ............ 7 ,,, . , 0 875 ..... 0, 60„ 1 20 ,.., , ,..,Q 0 90 ,...:. 0:80 ..,,,.......0,.60 :...........0.45 ,.. 0..40 ... .....,.., 0 79 1 57 1 10..:. ... 05 0 79 0.59 0 52 9 1 12$ 1 00 2.00 1 50 ...1 1.33 1.00 0.75 0.67 10 1 27 1 27 2 53 1 90 ... 1.69 1 27 n`� ......... 0 84 11 41 1 56 . ,,.-6.,'l 3 12 2 34 w 2.08 1 56 ,..,, 1 17 „ 1.04 i 4 . 1,693 2.25 ., .. 4.53, 38 ............. 3 �0 2 25 ...;, 1 69 ........ 1.5 0 ......., 18 2.257 .................. 4.00 8.00 ....,,.3 6.'0'0 5.33 4.00 3100 2.67 Bar Size Bar Dia Bar Area Number of Bars 1 2 1 3 4 5 3 0.375 0,11 0,11 „, .. 0 22' .. 0.33 0.44 0,55 .. Summit Structural Design ........., 0 20 ,, 0.39 0 59 Wall Design 0 98 .......... 5 .. ...... 0.625 Retaining ....:........ 0.31 ..... . 0.61 Flexure Design based on ULT Loads Residential, No Insp.? �---� Wall Thickness In 1.63 6 0 Restrained? 0 44 0 44 �aaoncy tof orrc te.B!e.inf, Retaining.Wali Loads Mu 0.17 k -ft M„ 0.12 k -ft EQ Point Load lbs/ft ...., 1.20 1.80 2.41 Apply at 0.6 H d 4 in d 4 in EQ PSF psf b 16 In b 12 in Pa 60 pcf f{m 1.5 ksi f'c 2,5 ksi Height Retained 2.67 ft fy 60 ksi fy 60 ksi Soil Moment 190 ft -Ib 3 80 5 07 6 33 EQ Moment 0 ft -lb rho b 0.011 rho b 0.018 Mu 324 ft -ib As max 0.342 in^2 A, max 0.641 In"2 2 25 2 25 Ag read 0.010 fn^2 A, regd 0.007 in^2 Min A,q (per code) 0,1921n^2 2,257 4.00 4,00 Min Av (per code) 0,1152 InA2 Bar Size Bar Dia Bar Area Number of Bars 1 2 1 3 4 5 3 0.375 0,11 0,11 „, .. 0 22' .. 0.33 0.44 0,55 ..... 4 ......... ........ Q 5 ........, ........ 0.20 ........., 0 20 ,, 0.39 0 59 0 79 0 98 .......... 5 .. ...... 0.625 ...:... .. . .. 0,31 ....:........ 0.31 ..... . 0.61 0 92 1,23 1.63 6 0 75 0 44 0 44 a, 68 ... 1.33 ............... 1.77 2.21 7 ... 0.875 0.59 ...... 0.60 ...., 1.20 1.80 2.41 3 01 8 1 .0.60 0.79 0.79 1 57 2 36 3 14 3 93 ......... 9 ...,.....1 128 1 00 1.00 2 00 3.00 4 00 5.00 1.0 1 27 1 27 1 27 2; 53 3 80 5 07 6 33 11 1.411.56 0 75 1 56 3 12 4 68 6 25 7 81 141.693 1 90 2 25 2 25 4.50 ................................ 6,75 9.00 ........ . 11.26 18 2,257 4.00 4,00 „ ........... 8.00 12.00 16.00 20,00 Equivalent area for o.c.bar spacing of ar Size Bar Dia Bar Area 6 8 1 9 12 16 18 3 0.375 0,11 0,22 0.17 0.150 1 1 0,08 0.07 4 0,5 0 20 0 39 0,29 0.26 0 20 0 i.. 0 13 5` 0 625 0.31' 0,61 0.46 .0,41 031 0.23 0.20 6 0 75 0 44 0,88 0.59 0 44 0 33 0 29 875 0.60 ;20 .0.66 0 90 0,80 0.60 „ 0 45 0 40 8 ....,,..,..0 1 6.79 ,,,.1 1 57 1.18 1 05 0 79 0 59 0 52 9 1 128 1 00' 2 00 1 50 1 33 1 00 0 75 0 67 1 27 1 27 2 53 1 90 1.69 1 27 0 95 0 84 .10 . ,.... 1;41 1.56 3 1 .. 2 34 2 08 1.56 1 17 1 04 „11 1 693 2,25 4 50 3 38 3;00 2 25 1 69 1 50 .14 18 7 2,257 .............. 4.00 ................, ., ..... ....6-,50961 8,0t� ....... 6,00 5,33 . .. ,,. ,. 4.00 . 3.00 _ 2.67 sum" 383 Rio Undo Ave, Chico, CA 95926 p. (530) 592-4407 www.summitchico.com Structural Calculations For: Client: Tim Duntsch North Valley Building Systems Proiect: Relocated Existing 12x48 Temporary Trailer Anchorage/Support Address: Lundberg Family Farms 5370 Church Street, Richvale, CA 95974 Qy�pf sSSIt�`, G. JO s & 6 isUj �L � . 0 201 MD. sT�T�OFCI:i��\P Note: Summit Structural Design (SSD) is not responsible for on-site inspection to assure compliance with the standards, sizes, materials, or workmanship specified herein. SSD is not responsible for any structural element or system not specifically noted in this set of specifications/calculations unless authorized in writing by SSD. Workmanship shall be of the highest quality and in all cases shall follow accepted construction practice, the latest edition of the California Building Code, and local building department standards. I . r- Summit Structural Design Project Page: Engineer: Date: Design of: MWFRS-Envelope Procedure ASCE 7-14 Section 28.6 Conditions: �• { '- r> 1. Simple Diaphragm -� CASE u 2. Low-rise 3. Enclosed 4. Regular Shaped f I f✓ `�, 5. Not Flexible '� f'✓�+ 1 6, Not Subject to: CASE A a) across wind loading b) vortex shedding c) instability (gallup/flutter) d)channeling effect i e) buffeting (upwind obstructions) 7. Approx. Symetrical Cross Section With Flat, Gable, or Hip % P Roof d 451 8. Exempt From Torsional Load Z , *� Cases Indicated in Note 5 of Fig. OC <Cases 28.4-1, or the Torsional Load CASE A do not Control the Design: (1) story and hd30 ft. or CASE 0. 13"Q?" (2) story max and light framed or (2) story max and flex. diaphragm L= 48 Long. Bldg. Dim. (ft) 4 2aL= 6 ft. T= 12 Transv. Bldg. Dim. (ft) --> 2aT= 6 ft. V= 110 Basic Wind Speed (I 10 or 115 mph) LCF= 0.6 Load Combination Factor A= 1.21 Adjustment Factor Kzt= 1 Topographic Factor Adjustment Factor for Bldg Height and h= 8 Mean Roof Height (ft) Exposure, X 0= 5 Closest Roof Angle Mean Roof Exposure 5°,10°,15°,20°,251,or 301 Ht. (ft) B C D IVIWFRS Wind Loads (psf), ps=LCF*A*Kzt*ps30 15 1 1.21 1;47 Location ps, 0=0 ps, 0=5 Min. Net Ovhg, 20 1 1.29 1.55 A-110 13,94 13.94 9.60 25 1 1.35 1.61 B-110 0.00 4.80 30 1 1.4 1,66 0-110 9.22 9.22 9.60 35 1.05 1.45 1.7 D-110 0.00 4.80 40 1.09 1.49 1.74 E-110 -16.77 -16.77 -23.45 45 1.12 1.53 1.78 F-110 -9.51 -9.51 1 50 1.16 1,56 1.81 G=110 -17 -11.02 -18.37 55 1.19 1.59 1.84 H-110 -7.33 -7.33 60 1.22 1,62 1.87 ,11 1412016 T11* iliaiit#s Design Maps Summary Report m x I�+ A TrliW SSI !^'t vM `� =fixuxtht Maps Summary Report Ni x; . imUSGSDesign d^ (, PatertriW =� User -Specified Input Building Code Reference Document 2012/2.015 International Building Code Si, = 0.270 g S,.,1 = 0.503 g SD2 = 0.335 g For information on how the SS and Si values above have been (which utilizes USGS hazard data available In 2008) response, please return to the application and select the "2009 NEHRP" building code reference document. Site Coordinates 39.4990N, 121.748°W Design Response Spectrum a.ss- Site Sol[ Classification Site Class D -"Stiff Soli" 0.72 0.49-- 0.64-- Risk Category I/II/VI 0.75.. 0,49 0.30 0.40 41 .q �;•. d , 0.19 0.24- 0.12 'AT 0.08 4&Vus 0,00 .00 0,00 0.20 -0.40 0.G0 0.90 1,00 Y.20 1.40 1.G0 1.80 360 0.00 0.00 0.20 0.40 0.0.90 1.00 1.20 1,40 1.60 Leo 2.00 Period, T (sec) Period, T (sec) TA'Al r 4 t }- 7i`` A� v 14 r WA Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or Implled, as to the accuracy of the data contained therein. This tool Is not a substitute for technical subject -matter knowledge, i http //ehp2-earthquake.wr.usgs,gov/deslgnmaps/us/summary.Php?template-minimal8 iatitude=39.499&long!tude--121.748&siteclass=3&riskcategory=D&editia.. 111 T11* iliaiit#s m x I�+ A TrliW SSI !^'t vM `� =fixuxtht �g Ni x; . d^ (, PatertriW =� USGS-Provided Output S5 = 0.605 g Sr,s = 0.796 9 Sos = 0.531 g Si, = 0.270 g S,.,1 = 0.503 g SD2 = 0.335 g For information on how the SS and Si values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions In the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. MCEa Response Spectrum Design Response Spectrum a.ss- 0.80 0a4 0.72 0.49-- 0.64-- 0.42 0.56 0.75.. 0,49 0.30 0.40 41 0.24 0.32 0.19 0.24- 0.12 0.1 0.08 0.0G 0,00 .00 0,00 0.20 -0.40 0.G0 0.90 1,00 Y.20 1.40 1.G0 1.80 360 0.00 0.00 0.20 0.40 0.0.90 1.00 1.20 1,40 1.60 Leo 2.00 Period, T (sec) Period, T (sec) Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or Implled, as to the accuracy of the data contained therein. This tool Is not a substitute for technical subject -matter knowledge, i http //ehp2-earthquake.wr.usgs,gov/deslgnmaps/us/summary.Php?template-minimal8 iatitude=39.499&long!tude--121.748&siteclass=3&riskcategory=D&editia.. 111 Project: Summit Structural Design Page: Engineer: Date: 11/7!2016 Design of: Seismic Load Development (ASCE 7.10) Seismic Design Category D Ss 0.605 Mapped 0,2 sec spectral response Occupancy 2 S1 0.27 Mapped 1 sec spectral response 1 1 Site Gass o i ♦ , In accordance with Ch 20. TL 16 SMS 0.80 Max Considered EQ SM1 0.50 Max Considered EQ eq(kips) SDS 0.531 Design Spectral Response (0.2 Sec) 1 ....... SD1 0,335 Design Spectral,Responsc (i 0 Sec),_ 167.47 1.00 System i Ught Framed Shear wails �► R 6.5 Omega 3 Cd 4 Ht Limit 65 Cs 0.08 12.8-2 Max Cs 0.54 Min Cs 0.02 (,01 outside of SJ) Ct 0.02 x 0.75 «.«..« ..... € Ta 0.10 Cu 1,4 Max T 0.13 No Limit for drift Use T 0.10 Aft Ss 0.605 Ss may be 1.5 if 5 stories and regular V. 0.082 *W Height to Roof (hn) _ 8 it V= 1.7 k Vert Dist Exp. (k) 1 Level ...tory Ht. (ft)i wl ips wl p t vx eq(kips) ps tap(kips) «ROOF 1 ....... �........ 81 20.93 167.47 1.00 1 71« 1,71 2,22 _.._. ..«..........I.. «.«..« ..... € ......... »: . ... «..{..................... i....«... € ....... » .» »...... «..,.........». .». .............».« '«............. ..» ' ...... «...........i,... »#.,...............«,.,... i «........ »...« 20,9 16 _ -- -. _- __ _ ------ � � -_. --r- - - �-- -- T...._-_. - �.------ f i r . _- Co pRnf =' -1.4 SUMMIT STRUCTURAL DESIGN PAGE. ENGINEER AJ ,, www,summiichico.com DATE: DESIGN OF ..... a"4�­ SOS r ' f j i 1 obex.:. — i C � t ' I [ +j 9. 44r•{F � , r --;:1 V 0c.� a } }. i� 0 PRQIECT: - PAGE, SUMMIT STRUCTURAL DESIGN ENGINEER: www.summltchico.com DATES t DESIGN OF i,.w +.,...o. �y � ' • � 1 +,�+� w 'w«{:a�. 3 j an+ v[n rI� . ,,., . �. 3 __ � �._ �w,.,......, All r c ` r �. ...,,,E ...., M..... ...w .,. .�..,...,. ... �,. ,.. .M �. ...� ..,. .(. � � � € S SSS t Sri[ 9 r r t , .. z . , i # I € 3 §. , ,. �� t E t ...w.w.wJ�+...,�,.,.iu..+.-i ,.. H� ,._. >E. >„ .,e ,1I1: .,�., i ..,« 3 , j t .• , � ..« , i � .A «w �,.::.,.._. w..,m.�� ... r t t S y 1 s -- -- —._ -- -- T -- T «- I PACIFIC CONSULTING ENGINEERS 2150 BELL AVE., #145 SACRAMENTO CA. 95838 Ph. 916-564-6028 FAX 916-564-6029 VERTICAL DESIGN Pacific Mobile Structures 4375 Farm Supply Road Ceres, CA 95307 VERTICAL DESIGN LOADS Code Roof Live Load: Roof Dead Load: Floor Live Load Floor Dead Load Exterior Wall Dead Load: Building Length: Building Modular Width: Metal Pier load rating: Gravel Bearing Pressure: Max. Support Spacing: DATE: 08/23/16 SHEET No. 1 of2 Job No. 16-782 Lundberg Family Farm 5370 Church Street Richvale, CA 95974 12 x 40 Commercial Modular Input Data: CALCULATIONS: Vertical Loads & Support Spacing Vo=(R I+Rd+FI+Fd+W d)W/2) Spacing=PNo 2013 CBC RI = 20 psf Rd = 10 psf FI = 50 psf Fd = 10 psf Wd = 10 psf L = 40 ft. W = 11.83 ft. P = 4,000 lbs Sa = 1,500 psf 592 plf 6.76 ft. on c.c. - T1E DOWNS LATERAL DESIGN Pacific Mobile Structures 4375 Farm Supply Road Ceres, CA 95307 12 x 40 Commercial Modular Input Data: Code Design Wind Pressure ( Vult=110 mph exp. C ) Seismic Load Factor Ss =1.5 Fa =1.0 SDs =1.01 Site Class D Roof Dead Load Wall Dead Load Floor Dead Load: Exterior Wall Hehgth Roof Heigth: Building Length: Building Width: Tie Down Working Load: Cross Drive Earth Anchors Wind Load: Seismic Load: Tie down Capacity: Seismic in Longitudenal Direction: No. of Tie Downs Required: Seismic in Transverse Direction: No. of Tie Downs Required: CALCULATIONS: SHEET No. 2 OF2 JOB No. 16-782 2013 CBC P = 16.8 psf V = 0.16 W Rd = 10 psf Wd= 10 psf Fd = 10 psf Ht= 8ft. Rht = 1 ft. L = 40 ft. W = 11.833 ft. td = 3,150 lb's Vw=P x (Rht + Ht) = 151.2 plf Vs=SI x (Rd+Fd+Wd) = 4.8 plf He=td x 1.33 x.707 = 2,962 lb's V long.= Vs x L = T long.=( V x W)/Hc = V tran.=Vs x W = T trans (Vw x L)/Hc = 192 plf Seismic Controls 1 Tie downs each 12' end 56.8 pif Wind Controls 3 Tie downs evenly spaced each 40 side i PACIFIC CONSULTING ENGINEERS 2150 BELL AVE., #145 SACRAMENTO CA. 95838 Ph. 916-564-6028 FAX 916-564-6029 VERTICAL DESIGN Pacific Mobile Structures 4375 Farm Supply Drive Ceres, CA 95307 VERTICAL DESIGN LOADS Code Roof Live Load: Roof Dead Load: Floor Live Load Floor Dead Load Exterior Wall Dead Load: Building Length: Building Modular Width: Metal Pier load rating: Asphaltl Bearing Pressure: DATE: 08/23/16 SHEET No. 1 of 3 Job No. 16-781 Lundberg Family Farm 5370 Church Street Richvale, CA 95974 24 x 60 Commercial Modular Input Data: CALCULATIONS: Vertical Loads & Support Spacing Loads at Outside Support: Vo=(RI+Rd+FI+Fd+Wd)W/2) = 592 plf Max. Support Spacing: triple pads Spacing=PNo = 6.76 ft. on c.c. Loads at inside support: Vi= FI+Fd x W/2 = 355 lbs Max. Support Spacing: Max. pier spacing not to exceed 8'- 0" o.c. Spacing=PNo = 11.27 ft. o.c. ' Y 12x 24 pad Spacing = 2 x 1500 / Vo = 8.45 ft. o.c. le support: Single 2 x 12 x 24 pads = 592 plf .port Spacing: Spacing = 2 x 20000 / Vo = 6.76 ft. o.c. 2013 CBC RI = 20 psf Rd = 10 psf FI = 50 psf Fd = 10 psf Wd = 10 psf L = 60 ft. W = 11.833 ft. P = 4,000 lbs S = 2,000 psf Vertical Loads & Support Spacing Loads at Outside Support: Vo=(RI+Rd+FI+Fd+Wd)W/2) = 592 plf Max. Support Spacing: triple pads Spacing=PNo = 6.76 ft. on c.c. Loads at inside support: Vi= FI+Fd x W/2 = 355 lbs Max. Support Spacing: Max. pier spacing not to exceed 8'- 0" o.c. Spacing=PNo = 11.27 ft. o.c. ' Y 12x 24 pad Spacing = 2 x 1500 / Vo = 8.45 ft. o.c. le support: Single 2 x 12 x 24 pads = 592 plf .port Spacing: Spacing = 2 x 20000 / Vo = 6.76 ft. o.c. , TIE DOWNS LATERAL DESIGN Pacific Mobile Structures S 1 Drive SHEET No. 2 OF 3 JOB No. 16-781 4,315 Farm .upp y 24 x 60 Commercial Modular Vs=SI x (Rd+= Ceres, CA 95307 He=td x 1.3:= 2,962 lb's V long.== Input Data: T V x W= 3 Tie downs each 24 end 2013 CBC 113.6 plf Wind Controls Code Design Wind Pressure ( Vult = 110 mph exp. C ) P = Site Class D, 1 = II SI = 16.8 psf 0.16 W Simplified Lateral Design, Cs not used Seismic Load Factor Ss =1.5 Fa =1.0 R=6.5 SDS =1.01 Rd = 10 psf Roof Dead Load Wd = 10 psf Wall Dead Load Fd = 10 psf Floor Dead Load: Ht = 8 ft. Exterior Wall Hehgth Rht = 2.5 ft. Roof Heigth: L = 60 ft. Building Length: W = 23.667 ft. Building Width: td = 3,150 lb's Tie Down Working Load: Wind Load: Seismic Load: Tie down Capacity: Seismic in Longitudenal Direction: No. of Tie Downs Required: Seismic in Transverse Direction: No. of Tie Downs Required: CALCULATIONS: Vw=P x (Rht = 176.4 plf Vs=SI x (Rd+= 4.8 plf He=td x 1.3:= 2,962 lb's V long.== 288 plf Seismic Controls T V x W= 3 Tie downs each 24 end V tran. = 113.6 plf Wind Controls T Vw x L)= 4 Tie downs evenly spaced each 60' side RIDGE BEAM SUPPORTS VERTICAL DESIGN Pacific Mobile Structures 4375 Farm Supply Drive Ceres, CA 95307 SHEET No. JOB No. 24 x 60 Commercial Modular 30F3 16-781 Input Data: Max. Support Spacing: Roof Live Load RI = R2 = 20 psf 16 psf Roof Live Load - Trib Area over 200 sq. ft. No. of Piers & ( ft.) Roof Dead Load: Rd = D = 10 psf 11.83 feet Building Module Width: P = 4,000 lbs Steel pier: P1 = 3,000 lbs Perimeter steel pier : SI = 1,500 psf Gravel Bearing Pressure: Calculations: Vertical Load at Mod -line: Trib. Area 200 sq. ft. or less Trib. Area over 200 sq. ft. W =RI+Rd x D = 355 psf W =R2+Rd x D = 308 psf Max. Support Spacing: No. Location Loads No. of 2"x12"x24" No. of Piers & ( ft.) ( lbs.) P.T. BASE PADS PIER RATED LOADING FRONT 1 0 9,230 4 4 -3000 lbs 2 60.00 9,230 4 4 -3000 lbs _ u LJ) -j w AO.0 SITE AND D UTILITY P PLAN 0 t RICE CAKE EXPANSIO� BUILDING Al RAMPS SSTAIRS RTHVALLEY BUILDING SYSTEMS V�PROJECT m lefe Concrete and Building Service LOCATION 51.0 STRUCTURAL RAL NOTES .4% • d .� dd d .• 4 d .�d, : d•� d d • LN�T . o .4. Q. . , d d , � C7 O d •d dd .. dv. . • �a ••d d ••... d d Q d D d ad d d -.-� - .-� xy . _ a L— IN D ALE AVE 15 SD S2.1 Q wQWp d o4d: d ! ICE AVE d..a dd S3.1 STRUCTURAL DETAILS p d LOCATION MAP d CLEAN AIR/ CLEAw a 7 QW ,d. VANPOOVEV ANPOOL/Ed COMMERCIAL CALGREEN V ��d -- dd . • ----- - c„Q Q Q d dp d 4 I a d d NNLQW Q CONSTRUCTION PLAN d d 4 d 4 Q4 4 Ad d dd EXISTING RICALPLAN d d r 2 WATER LINE Q E ELECT Q 4 4 W4 Q 1 d A QILERANCHORAGE/ SUPPORT ' 12X481MODULAR TRA NEW UNDERGROUND 2. 1_78212X40MODULAR TRAILER ANCHORAGE/ SUPPORT 00 WATER -Q(wTrV.0 WATER LINE TO L_ BREAKROOM AND RESTROOM 'MAILERS AGE/SUPPORT 241X601MODULAR TRAILER ANCHORry 0MPROJECT DIRECTORY z LO 120 TO PL OWNER. EXISTING UNDERGROUND 2 ELECTRICAL CONDUIT LUNDBERG FAMILY FARMS STUB, SEE E1 370CHURCH STREETWATER POC �� U . zWATER � RICHVALE C , -� 4x —► 4x —► _ L . . A 9 5 974 EXISTING 4 SEWER CLEAN � APN. 029110O3VUT 4SWER - - -__-_ � aTA#uM SIDE CF Ill"AM 4 SEWER 41 PROJECT ENGINEER. o�. GREGORY A. P1ETZ ARCHITECT T CLEAN OUT POR SEWER + 2. WATER O GREG PIETZ CLE r N OUT CLEAN OUT Wm - �... �(530)894-5719 5 BUM Ion Issue Date No. CoLeny I � I t - I ffiJ. Project Name and Address C EAMON G+ti1!?. 53I.L+ s�a mS TM tCr. GENERAL CON TRAC TOR.- ALL %O PORTABLE o LUNDBERG �I I �� FnM TIM DUN TSC H My am TRIACx9p 11"C" Do 911117 trio no rM01— OTM.4"t aw" I TRAILER AREA MAY. .� NORTH VALLEY BUILDING SYSTEMS, , INC. REET 2. ,ETo T 5370 CHURCH ST I I . 95974 �� COURT RICHVALE CA �dlLts� � O:SEVILLE S AT > CT COUNTY O ��. I 2 8 �. A CA 959 CHICO G' 61,18LI= TO, NOV 2 9 2016 (530)345-7296 . i i PALL !�ttt€a DEVELOPMENT gilAouk 04 ft" OM T CA= dCAOOA " 415-10 SERVICES Gs�'I'a4t1.8 � 1 / . X . CAUIA PERMIT # T1QK 1I BUTT � E COUNTY D t EVELOP MENT SERVIC RE �s VI E W E D FOR Project I I 16-956 N•®V 2 9ZQti O STRUCTURAL ENGINEER: 11/17/16 AOmO Its L 4 $ LI NTS N TURAL DESIGN SUMMIT STRUC f3► �G C\J r Z OHNSO N � � ANDYJOHNSON ����� t 40Y ucap - 3 4 7 530 592 4 0 . _ ri.PA , ruaN t - I ffiJ. Project Name and Address C EAMON G+ti1!?. 53I.L+ s�a mS TM tCr. GENERAL CON TRAC TOR.- ALL %O PORTABLE o LUNDBERG �I I �� FnM TIM DUN TSC H My am TRIACx9p 11"C" Do 911117 trio no rM01— OTM.4"t aw" I TRAILER AREA MAY. .� NORTH VALLEY BUILDING SYSTEMS, , INC. REET 2. ,ETo T 5370 CHURCH ST I I . 95974 �� COURT RICHVALE CA �dlLts� � O:SEVILLE S AT > CT COUNTY O ��. I 2 8 �. A CA 959 CHICO G' 61,18LI= TO, NOV 2 9 2016 (530)345-7296 . i i PALL !�ttt€a DEVELOPMENT gilAouk 04 ft" OM T CA= dCAOOA " 415-10 SERVICES Gs�'I'a4t1.8 � 1 / . X . CAUIA PERMIT # T1QK 1I BUTT � E COUNTY D t EVELOP MENT SERVIC RE �s VI E W E D FOR Project Sheet 16-956 Date 11/17/16 AOmO Scale NTS I L, Revision: Date: By: cV EEO ►--� 4 W C-� 00 M N - .w C N � 01 'Q e4 r U .0 bA 0 I' � b W -- - 1 -T- o � x M h 00 V1 V 1 i I ---i L Iii ~ e --I T�ll V C ✓ ^ W �n V 1 ^ , u✓ Z: v O AP Y A. * NosC21283 R�i. _7/17 NDBERO FARMS RAMP5 4 5TAI R5 Date AUGUST 2016 Scale Dram CA5 Job 16-221Q Sheet NIL AF IL Of Sheets cV N e4 r 0 I' -- - 1 -T- i Ili. CO F SLABS ON GRADE SHALL BE PER THE CONTRACTOR.' SUMMIT STRUCTURAL DESIGN RECOMMENDS UNrY D . EV _ R DE. AT GARAGE SLABS .USE 4 THICK S.O.G. G AS A MINIMUM SLAB ON GRA , THE FOLLOWING ' �Ar C RVj AQP ®1 M - W� �Nr WITH #3 BARS AT 15 O.C. EACH WAY ABOVE MID DEPTH OF SLAB OVER 2 SAND, OVER OZ, COM D FO s��1�� �� R cE 2 �l s _ a_ AGGREGATE BASE. USE 3 1 2 SLAB WITH #3 AT 15 E.W. ABOVE � BARRIER OVER 4 AGGR / MOISTURE� MID -DEPTH TH OF SLAB, OR 6X6 WW ABOVE MID -DEPTH EPTH OF SLAB WITH SAME SUB -SLAB BUILDUP Y AT ALL OTHER AREAS. - G SAW CUT TOP 3/4 OF SLAB FOR CRACK CONTROL AT INTERVALS NOT TO EXCEED 10'-0" WHERE -UN-REINFORCED. C T AT INTERVALS NOT TO EXCEED T-0" WHERE SLAB IS SLAB IS REINFORCED SAW U oQ�pFESS/ONgI C. J F � 0 c� z w 0 m rn � N 691 z � 1 J C V ' L I 1 P F OF CAL F kill -711(4 THESE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE ONLY WITH THE H ATTACHED STRUCTURAL CALCULATIONS 383 Rio Lindo Ave. Suite 200 Chico, CA 95926 P. 530.592.4407 SummitChico.com Ftt.}FtT" VALLEY BUILDING SYSTEMS Ln G Uj Q LJL c J G Q LL 0 zW Cn m< OIU z W J J N Q 1..1� U W U- 10 UW J O Q re , I- Q- O c� G , W REVISIONS: DATE: 10/05/16 SCALE: NTS DRAWN BY: ACJ JOB NUMBER: 16-262 SHEET: sloo LSTRUCTURALGENERA 1. GENERAL 3. CONCRETE REINFORCING CONTINUED A 1 ALL WORK SHALL CONFORM TO THE 2013 CBC AND ALL APPLICABLE LOCAL CODES. REINFORCEMENT COVER SHALLB AS FOLLOWS: B THE ENGINEER (SUMMIT STRUCTURAL DESIGN HAS PROVIDED AND IS RESPONSIBLE FOR SPECIFIC STRUCTURAL ITEMS ONLY. ALL OTHER REQUIREMENTS OF THE BUILDING CODE CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO SOIL: 3 CAP ACCESSIBILITY INCLUDING WATERPROOFING FIREPROOFING DRAINAGE HANDICAP , EGRESS CONCRETE WITH SOIL OR WEATHER EXPOSURE: " SNOT. SPECIFICALLY SHOWN DESIGN REQUIREMENTS S PARKING, AND ALL OTHER G REQUIREMENTS, PA Q Q , ' # BARS AND SMALLER 1 2 5 / N CALCULATIONS ARE THE RESPONSIBILITY OF THE CONTRACTOR OR IN THE STRUCTURAL DESIGN , #6 BARS AND LARGER 2" I HESE ..OWNER. SHOULD ANY CHANGES BE MADE FROM THE DESIGN AS SPECIFIEDN T CONCRETE WITHOUT SOIL WEATHER EXPOSURE: 3 4 / E R THE THE ENGINEER FROM THE ENGINE N DOCUMENTS WITHOUT THE WRITTEN APPROVAL, WILL ASSUME NO RESPONSIBILITY FOR ANY ELEMENT OR SYSTEM OF THE STRUCTURE. J' )( NT SHALL BE RADE 6 6 U.N.O. BOTTOM REINFORCEME L G 0 PER ASTM A 15 U LAP TT M 60 ) BAR DIAMETERS U.N.O. AND LAP TOP REINFORCING PLACED ABOVE 12 OF CONCRETE OR THE DRAWINGS AND CALCULATIONS REPRESENT THE FINISHED STRUCTURE AND UNLESS MORE, (80) BAR DIAMETERS U.N.O. O SPECIFICALLY NOTED OTHERWISE DO NOT SHOW THE METHOD OF CONSTRUCTION. THE B THE METHOD OF CONSTRUCTION AND SHALL PROVIDE ALL CONTRACTOR IS RESPONSIBLE OR L F K ) # 5 AND LARGER REBAR SHALL NOT BE RE-BENT. AND THE W MEASURES NECESSARY TO PROTECT THE PUBLIC, CONSTRUCTION WORKERS, FORMING, SHORING STRUCTURE DURING CONSTRUCTION.' SUCH MEASURES SHALL INCLUDE F L) ALL REINFORCING STEEL AND ANCHOR BOLTS SHALL BE ACCURATELY LOCATED AND BRACING SCAFFOLDING ETCETERA. SECURED I ADEQUATELYN POSITION BEFORE AND DURING CONCRETE PLACEMENT. D ) E O CONSTRUCTION IS NOT FULLY SHOWN ON THE DRAWINGS OR IN IF A PARTICULAR FEATURE S R THE SAME CHARACTER A SIMILAR E I T LA THE CALCULATIONS, THEN IT SHALL BE CONSTRUCTED N 5. MASONRY CONDITIONS THAT ARE SHOWN ON THE DESIGN N DOCUMENTS. A MASONRY UNITS SHALL CONFORM TO CBC STANDARD 21-4 ` GRADE N PEI AIND CEMENT M TY E) ONS NOTED AS EXISTING MUST BE FIELD VERIFIED BY THE CONTRACTOR ANY CONDITI N , AND O D BEA SHALL BE SINGLE R DOUBLE OPEN END BON M UNITS. ANY DISCREPANCIES MUST BE BROUGHT TO THE ATTENTION ENGINEER WITHOUT OF THE N IN .WITH CONSTRUCTION PRIOR TO THE REVIEW OF THE ENGINEER. PROCEEDING B ) SHALL BE 1500 PSI WITH COMPLIANCE VERIFIED AS REQUIRED PER CBC SECTION F m MIN M Q ABBREVIATIONS 2105.3. F ) FLOORS, ETC... IS THE (ROOFS, FOUNDATIONS GARAGE LO ALL WATERPROOFING AND FLASHING ) CONTRACTOR OR OWNER. RESPONSIBILITY OF THE CONTRA C )CONFORMING BE COMPLETELY FILLED WITH GROUT TO ASTM C279 TYPE S EACH CELL SHALL STRENGTH OF 2 000 PSL WITH A MINIMUM , AB ANCHOR BOLT O K KIPS G) SHOP DRAWINGS:• SHOP DRAWINGS ARE SUPERCE DED BY THE STRUCTURAL DRAWINGS UNDER ADDL ADDITIONAL L ANGLE CONTRACTOR SHALL VERIFY THAT ALL CONSTRUCTION IS IN CIRCUMSTANCES. THE GENERAL C D ) S - �� THE GREATER OF 80 BAR DIAMETER OR 3 0 . LAP REINFORCINGH E AD J ADJACENT J LLH ON LEG HORIZ. LONG .ALL S FULL AGREEMENT WITH THE LATEST STRUCTURAL DRAWINGS. REVIEW OF HOP DRAWINGS BY ALT ALTERNATE LL V LONG LEG VERT. THE ENGINEER OF RECORD DOES NOT GUARANTEE IN ANY WAY THE THE SHOP DRAWINGS ARE E �� OR BOLTS WITHIN 2 OF THE CENTER OF A CELL. LOCATE ANCHOR :ARCH RAL ARCHITECTURAL LONG LONGITUDINAL CORRECT NOR DOES IT INFER THAT THEY SUPERCEDE THE STRUCTURAL DRAWINGS. BLDG BUILDING LSL LONG SLOTTED HOLE BLKG BLOCKING LVL LAMINATED VENEER LUMBER H) WALL FINISH SYSTEMS SUCH AS STUCCO SHALL BE APPLIED OVER FOAM BASE OR OTHERDESIGN9. LOADS BM B BOTT O BEAM BOTTOM O MAX MB MAXIMUM MACHINE BOLTS Y ALLOWI NG THE FINISH TO EXPAND AND CONTRACT TRACT WITHOUT METHOD OF ADEQUATELY B F T BEAT TO FIT MECH CAL... MECHANICAL CRACKING . THE OWNER OR CONTRACTOR SHALL BE RESPONSIBLE BLE FOR ANY DEFECTS IN THE A) HAS BEEN DESIGNED FOR THE FOLLOWING CRITERIA PER CBC CHAPTER 16 THE , BTWN BETWEEN MFR MANUFACTURER FINISHES. DIVISIONS III 111, AND IV U.N.O.: C6 CARRIAGE BOLTS `MIN MINIMUM 1 SPECIAL INSPECTION. SPECIAL INSPECTION PER 1701 OF THE CBC SHALL BE PROVIDED B SEISMIC. CCJ CIP CONTROLJOINT CAST -IN-PLACE CONCRETE MISC. MTL , MISCELLANEOUS E MAL T FOR THE FOLLOWING TYPES OF CONSTRUCTION: NA CJ CONSTRUCTION JOINT N NEW WELDING OF STRUCTURAL OR REINFORCING FORCING STEEL CLEAR NS NEAR SIDE ECHAN ICAL CONCRETE ANCHORS EPDXY/MECHANICALM C WIND. "CLR CMU CONCRETE MASONRY UNITS NSA NELSON STUD ANCHOR THE SPECIAL INSPECTOR SHALL BE ACCEPTABLE TO THE STRUCTURAL ENGINEER AND BUILDING NA COL COLUMN NTS NOT TO SCALELE DEPARTMENT SHALL BE ICBO QUALIFIED, AND THEIR EXPERIENCE SHALL BE COMMENSURATE CONC CONCRETE OC ON CENTER . WITH THIS TYPE PE OF PROJECT. D LIVE LO ADS. " CONN CONNECTION OD OUTSIDE DIAMETER. FLOOR 100 PSFCOMMERCIAL DECK SERVING OFFICES) ) CONSTR CONSTRUCTION OH OPPOSITE HAND CONT CONTINUOUS OPNG OPENING 2. SITE WORK FOUNDATIONS CONTR CONTRACTOR OVS OVERSIZE ROUND HOLE CP COMPLETE PENETRATION P DF POWDER RIVEN FASTENER WD R D A ' _ ASSUMED MAXIMUM SOIL BEARING 1500 PSF PER CBC TABLE 1806.2 NO SOILS REPORT CTR CENTER PERP PERPENDICULAR PROVIDED). CTSK COUNTERSINK PL PLATE DBL DOUBLE PLWD PLYWOOD B) BUILDING SITE IS ASSUMED TO BE DRAINED AND FREE OF CLAY OR EXPANSIVE SOIL. ENGINEER DF DOUGLAS FIR PLCS PLACES O ECHNICAL REVIEW OF SITE, OTHER CONDITIONS ENCOUNTERED .HAS NOT MADE A GE TDF -L DOUGLAS FIR -LARCH PP PARTIAL PENETRATION ATTENTION OF THE ENGINEER. MUST BE BROUGHT TO THEA DIA DIAMETER PT PRESSURE TREATED DJ DOUBLE JOIST P/C PRECAST CONCRETE E C) THESE CALCULATIONS ASSUME STABLE, UNDISTURBED SOILS AND LEVEL OR STEPPED FOOTINGS. EA EACH P/T POST -TENSIONED ANY OTHER CONDITIONS SHOULD BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO EF EACH FACE REINF REINFORCEMENT THE CONSTRUCTION OF THE FOUNDATIONS. EL ELEVATIONDATUM ( ) REQ'D REQUIRED - ELEV ELEVATION VIEW OR ELEVATOR SC SLIP CRITICAL D) FOOTINGS INCLUDING RETAINING WALL FOOTINGS, SPREADEAD FOOTINGS, WALL FOOTINGS, EN EDGE NAILING SEOR STRUCTURAL ENGINEER OF AND GRADE BEAMS SHALL BEAR ON UNDISTURBED SOIL WITH A FOOTING DEPTH BELOW EQ EQUAL RECORD S PER LOCAL REQUIREMENTS). FROSTLINE 1 2T024A P (ES EACH SIDE SHTG SHEATHING E EXISTING SIM SIMILAR E) BOTTOM OF ALLFOUNDATION TRENCHESHES SHALL BE CLEAN AND LEVEL.L. EXP EXPANSION SOG GRADE SLAB -ON -GRADE EXT EXTERIOR STD STANDARD F o o AWAY FROM ALL ALL FINISHED GRADE SHALL SLOPE A T A MINIMUM SLOPE OF 5/ A EW EACH WAY STIFF STIFFENER FOUNDATIONS A MINIMUM OF 10 FEET HORIZONTAL. FF FINISH FLOOR STL STEEL FIN FINISH SQ SQUARE UARE G) DATIONS S HALL NOT BE SCALED FROM PLAN OR DETAIL DRAWINGS. FOUNDATIONS FJ FLOOR JOIST SS STAINLESS STAT S STEEL FLR FLOOR SWS SHEAR WALL SCHEDULE H) FILL MATERIAL SHALL BE FREE FROM DEBRIS, VEGETATION, AND OTHER FOREIGN SUBSTANCES. FNDN FOUNDATION SYM SYMMETRICAL FOHC FREE OF HEART CENTER T&B TOP &BOTTOM I) - RETAINING WALLS. SLOPE PIPE USE 4 DIAMETER PERFORATED PIPE SUB DRAIN BEHIND ALL RETAIN N FOS FACE OF STUD TO(P) - TOP OF (PLYWOOD) TO DRAIN TO DAYLIGHT FS FAR SIDE TOC TOP -OF -CONCRETE TOP OF CONCRETE FTG FOOTING' TOF TOP OF FOOTING TOP -OF -FOOTING J ENGINEER MUST ADJACENT SLOPES A GEOTECHNICAL GI FOR FOOTINGS PLACED OR ADJAC , GA GAUGE TOS TOP -OF -STEEL O 2013 CBC. THIS 8 8.7.1 F APPROVE FOOTING PLACEMENTS N VIOLATION OF FIGURE 1 0 GALV GALVANIZED TOW TOP -OF -WALL ENGINEER SHALL NOT BE LIABLE FOR ANY FOUNDATION NOT IN STRICT CONFORMANCE TO GLB GLUE -LAM BEAM TN TOE NAIL SECTION 1808 OF THE 2013 CBC. HDG HOT DIPPED GALVANIZED TYP TYPICAL HDR HEADER LINO UNLESS NOTED OTHERWISE H RWISE K. ) ED OR MODIFIED, NOT SUBSTANTIALLY INCREASED M WHERE LOADING TO EXISTING FOUNDATIONS IS , HGR MANGER (SIMPSON) VERT VERTICAL NO DESIGN RECOMMENDATIONS HAVE BEEN MADE FOR THE SUITABILITY OF THE EXISTING HORIZ HORIZONTAL WP WORKPOINT FOUNDATIONS. ONLY THOSE FOUNDATIONS WHERE LOADS HAVE BEEN ADDED BY A SECOND FOU ID INSIDE DIAMETER WWF WELDED WIRE FABRIC Y HAVE BEEN INCLUDED IN THE DESIGN. THE OWNER SHALL BE ADVISED THAT EXISTING STORY INT ` INTERIOR. W WITH FOUNDATIONS MAY NOT BE STRUCTURALLY ADEQUATE AND SETTLEMENT, CRACKING, AND JST JOIST W/O WITHOUT OTHER PROBLEMS ASSOCIATED WITH EXISTING FOUNDATIONS ARE BEYOND THE SCOPE OF THIS JT JOINT. SING FOUNDATIONS IS REQUIRED AGEOTECHNICAL ENGINEER DESIGN. IF REVIEW OF THE EXIT , EXTENT AND ADEQUACY ACY OF THE EXISTING SHOULD BE CONTACTED TO DETERMINE THEE Q , _ U UN MODIFIED PORTIONS OF THE F O NDATIONS. SHEET INDEX 3. CONCRETE / REINFORCING A) CONCRETE SHALL HAVE A MINIMUM 28 DAY STRENGTH OF 3,000 PSI U.N.O. 2 00 PSI ED ON 5 DESIGN BAS ) ( � S1.0 STRUCTURAL NOTES AND ABBREVIATIONS R VIATIONS C) ALL CEMENT USED SHALL CONFORM TO ASTM C-150 AND SHALL BE TYPE II OR ALKALI. S2.1 FOUNDATION PLAN/DECK 'PLAN TYPE III LOW D) - WHICH ARE AGGREGATE SHALL CONFORM TO ASTM C 33 AND SHALL NOT CONTAIN MATERIALS W _ S3.1 TYPICAL DETAILS _ TEST DATA IS S DETERMINED BY ASTM C 227 289 AND 295. IF ALKALI REACTIVE A , UNAVAILABLE IN REGARDS TO ALKALI REACTIVE MATERIALS, PROVIDE CEMENT WITH A 0 o Y WEIGHT. MAXIMUM ALKALI CONTENT LESS THAN 0.45/ B E) CONCRETE EXPOSED TO FREEZING OR THAWING SHALL BE PROTECTED N ACCORDANCE TO THE LATE ST EDITION OF THE ACI 318. PER Mir CO F SLABS ON GRADE SHALL BE PER THE CONTRACTOR.' SUMMIT STRUCTURAL DESIGN RECOMMENDS UNrY D . EV _ R DE. AT GARAGE SLABS .USE 4 THICK S.O.G. G AS A MINIMUM SLAB ON GRA , THE FOLLOWING ' �Ar C RVj AQP ®1 M - W� �Nr WITH #3 BARS AT 15 O.C. EACH WAY ABOVE MID DEPTH OF SLAB OVER 2 SAND, OVER OZ, COM D FO s��1�� �� R cE 2 �l s _ a_ AGGREGATE BASE. USE 3 1 2 SLAB WITH #3 AT 15 E.W. ABOVE � BARRIER OVER 4 AGGR / MOISTURE� MID -DEPTH TH OF SLAB, OR 6X6 WW ABOVE MID -DEPTH EPTH OF SLAB WITH SAME SUB -SLAB BUILDUP Y AT ALL OTHER AREAS. - G SAW CUT TOP 3/4 OF SLAB FOR CRACK CONTROL AT INTERVALS NOT TO EXCEED 10'-0" WHERE -UN-REINFORCED. C T AT INTERVALS NOT TO EXCEED T-0" WHERE SLAB IS SLAB IS REINFORCED SAW U oQ�pFESS/ONgI C. J F � 0 c� z w 0 m rn � N 691 z � 1 J C V ' L I 1 P F OF CAL F kill -711(4 THESE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE ONLY WITH THE H ATTACHED STRUCTURAL CALCULATIONS 383 Rio Lindo Ave. Suite 200 Chico, CA 95926 P. 530.592.4407 SummitChico.com Ftt.}FtT" VALLEY BUILDING SYSTEMS Ln G Uj Q LJL c J G Q LL 0 zW Cn m< OIU z W J J N Q 1..1� U W U- 10 UW J O Q re , I- Q- O c� G , W REVISIONS: DATE: 10/05/16 SCALE: NTS DRAWN BY: ACJ JOB NUMBER: 16-262 SHEET: sloo oQ�pFESS/pN�l C. Llj N C 691 8z � * 3 /1 J'9T CIV1\- ��\Q F0F CALF (1/1-7/16 THESE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE ONLY WITH THE ATTACHED STRUCTURAL CALCULATIONS ------------ 383 Rio Lindo Ave. Suite 200 Chico, CA 95926 P. 530.592.4407 SummitChico.com NORTH VALLEY BUILDING SYSTEMS (ccn G i� Q L- z Jc G Q U- W m z i� Q 0 Z V w � J J < U -r LU 0 U zLLJJ Q 0 LL Q O c� G W REVISIONS: DATE: 10/05/16 SCALE: 1/4" 1'-0" DRAWN BY ACJ JOB NUMBER: 16-262 SHEET: S2sl i —III— III 111_111 II _I 111 A 3 AT 12 O.C. NATURAL 1 4 CON T. # a II _ 0 – GRADE P LA 3 0 MIN. it -ON SEE NOTE 3 PROVIDE 3/4" CHAMFER WHERE WALL ABOVE SOG PER PLAN TYP STEP COUNT 1 , T DIMENSIONS PER :DOES NOT OCCUR TYP ARCH PER ARCH 4 CONT DIMENSIONS 4 NOSEBAR MECH. PAD PER ARCH _ TYP TYP w OR CURB 1 0 - p a x4 0 — — #4 SEE - — M AT V-6" O.C. _ — cn NOTE 3 - — DIMS PER v II o: - ARCH oQ 6" 6» , . �- „ rr— v LAP 3'-0" - ( - - - - MIN. II III III Ill III III: #3 AT III III ' — 12 O.C. 1,_O» 2x4x2'-0 KEY , » TYP. SLAB AT 1 -6 O.C. AT 3'-0" O.C. CONSTRUCTION #4 AT 16 O.C. EA. WAY — c� #3 - w ...REIit-on _ — NFORCING JOINT PER PLAN- -I��—ISI— NOTES... i PROPERLY PREPARED SUBGRADE 1. PREPARE SUBGRADE PER SOILS REPORT FAPPLICABLE. PER SOILS REPORT WHERE APPLICABLE) ) 6 6- 2. SEE PLAN FOR RECOMMENDED REC M ENDED SLAB REINFORCING. E 3. MAY REDUCE DIMENSION TO 6 IF WALL ABO DOES SNOT OCCUR. 4. GENERAL CONTRACTOR SHALL PROVIDE CONTROL AND CONSTRUCTION JOINT NT LAYOUT. PLAN FOR ENGINEERS REVIEW PRIOR TO CONCRETE RETE PLACEMENT. TYPICAL CONCRETE DETAILS 6- 3 S_ TYPICAL STAIR -ON -GRADE DETAILS NO SCALE S3.1 NO SCALE S3.1 WATERPROOFING DRAINAGE, AND , CORROSION PROTECTION TI BY OTHERS " FULLY GROUTED 8 CMU BLOCK PROVIDE 4 X 32 E.S. ,TOP SEE 4 S3.1 FOR MORE � # WALL H<32 WITH 5 A 16 „ INFO 0 N .GONG. RAMP ( ) # „ T O.C. AND BOTTOM OF EACH FENCE HORIZ. AND D 4 AT 16 O.C. -VERT. , POST TYPICAL CENTERED ON FOOTING BELOW N CONTRACTOR TO PROVIDE SLEEVES AS REQUIRED TO 40Q SECURE FENCE TO CMU WALL SEE ARCHITECTURAL DRAWINGS 0 0 0 0 0 NOTE: PROVIDE MASONRY CONTROL JOINTS AT 25'-0" O.C. i O O o O o 0 0 CORROSION PROTECTION BY OTHERS r P P J A w Q OPEN FENCE GUARDRAIL. x WHERE 0 0 o I o OCCURS B w r Y OTHERS CONTRACTOR FOOTING E o_ o: TRENCHES SHALL v I 0 o T PROVIDE SLEEVES AS REQUIRED BE CLEAN AND LE z � VEL AND v w TO SECURE FENCE TO MU W c� C ALL _ w BEAR ON UNDISTURBEDfm= f m 1.5 KSI o NOTE. PROVIDE CONTINUOUS VERTICAL CONTROL JOINTS PER PLAN. NATURAL SOIL. ,f 60 ;KSI Q w 0 •w w z CONT. VERT. _ „ • I NO S 48 NOTES: 11 CONTROL .JOINT v „ 1. WATERPROOFING AN a 16 D DRAINAGE Q � PROVIDE #4 r— AT 32 N BY OTHERS d- O.C., TYPICAL WHERE OCCURS w 000 w 2. WALL' MAY NOT PERFORM AS I IN ! TENDED AND MAY FAIL UNLESS A` „ STRICT 4 MIN. THICK S ADHERENCE IS MAINTAINED DECK E RAKE BACK MORTAR AND C RAMP DETAIL IN ALL ASPECTS OF DETAIL SLAB -ON -GRADE ADDED `VERT. BAR AT PROVIDE BACKER ROD NO SCALE • 53.1 REQUIREMENTS (WHERE OCCURS) AND SEALANT BY EACH SIDE OF JOINT TYP „ , I_ OTHERS TYP EACH SIDE..:.. _ ._ VERIFY +37 ABV 'RVFIN. GRADE TO WATERPROOFING DRAINAGE, - - NOTES. A AGE AND CONTROL JOINT , MATCH TRAILER F.F. - » CORROSION PROTECTION BY OTHERS I G A TH 1 MINIMUM REINFORCING SHALL z 8 BE #4 AT 16" O.C. VERT NOM.I II I WATERPROOFING AND NOTE. HAND - DRAINAGE BY OTHERS AND 5 AT 16 O.C. HORIZ. UNO. RAILS AND I # o OR PROVIDE P GUARDRAILS BY OTHERS w E WEE IM REINFORCING TO m HOLES TO PREVENT 2. ALL TR � : N I I MATCH SIZE OF WALL 4 :THICK SLAB ON » w I BUILDUP OF WATER _ M FULLY GROUTED CMU BLOCK 8 : _ � - BEHIND WALLS, TYP REINFORCING. LAP ALL GRADE WITH #4 AT" " LAP 2'-0" ; II • »WALL H 32 WITH 5 T S A 16 O.C. 4 f CURB WHERE ( ) # .- I 0 BAR DIA. MIN. 2 O.C. E.W. „ J. .SPLICES 5 TYPICAL f X I OCCURS BY OTHERS HdI�IZ. AND 4 AT 16 O.C. VERT. 4 VERT. TRIM I CENTERED ON FOOTING' BELOW T OPTION I 3. AT CONTRACTOR'S O EQ E » „ _ 24 x 24 CORNER BARS AT EA. INTERSECTION X — II ROUGHEN 1 1 2 LR MAY BE .USED IN LIEU` OF C o. a O RIZ. HOOKED BARS. SURFACE 1 4 � w O d 16 H0 0 — o "AMPLITUDE a .o „ O 8 M 0 0 0 0 0 0 0 0 (I— NOM. - O •o• O ... SLOPE FINISHED .GRADE " o 0 0 _ ALTERNATE OR CONCRETE BY OTHERS 4 AT 12 O.C. # HOOKS AWAY FROM FOUNDATION HOOK REINF. TYP. _.._ INTERSECTION — AT ALL CORNERS 4 A 0 0 0 0 0 —. _ T 9 O.C. TOP AND BOTTOM o o # PROPERLY Y & INTERSECTIONS COMPACTED 0 6 GIP.. a 3 CLR HORIZ. REINFORCING WALL WITH 4 a COMPETENT BASE „ o • VERT IM IN BOND BEAM UNITS AT 24 O.C. E.W.co (3) TR ,AT I „ o z F_TYPICAL 8 CENTERLINE- F -AT EA. CORNER 0 WALL 3 CLR R � M/ r » o - 2 0 00 , 12 • • • 8 z _ U F c ..2500 PSI rt co _ UN F 60 KSI � Y o R Fco �V p CO 4 O F � NOTES: qr D W Nr „ TE � �• �' s ® F CUT BLOCK G R --� U F vi 16 _ O C r n� E z P R s MATCH Z A TOM �`'"�.. a � . LO C 1 SLOPE SLAB A EUI 2 VERTICAL S REQUIRED RED PER ARCH. BOND BEAM ) . O NOTE: SPECIAL INSPECTION CORNER JAMB OR END TION UNIT. TRIM BARS `®y REQUIRED PER CBC 1704.5.1 2. SHORE AS REQUIRED UNTIL OG A Q S REACHES 75% STRENGTH. TYPICAL MASONRY WALL REINFORCING 7 SLAB -ON -GRADE AT RAMP DETAIL 4 TYPICAL SITE CMU WALL SCHEDULE 1 NO SCALE - NO SCALE NO SCALE 53.1 53:1 S3.1 FESS/o/v C L/O CO L�j N 69 8 * X 8 c I V 1 OF M� �1/I -7 11(4 THESE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE ONLY WITH THE ATTACHED STRUCTURAL CALCULATIONS 383 Rio Lindo Ave. Suite 200 Chico, CA 95926 P. 530.592.4407 SummitChico.com NORTH VALLEYBUILDING SYSTEMS cc G Q U_ _I - S Q U_ V W m 0 Q Z U J W J J i Q U DW U W UJ Q OC Q O c� G W REVISIONS: DATE: 10/05/16 SCALE: NTS D ACJ DRAWN BY: JOB NUMBER: 16-262 SHEET: I NOTA: THE PROJECT MANAOER OR OENERAL GONTRAGTOR WILL BE THE RESPONSIBLE PARSON TO GOLLEGT AND PROVIDE \/ERIFIGATION OF GALGREEN COMPLIANCE TO THE BUILDING INSPECTOR PRIOR TO BUILDING FINAL. Revision: Date: By: CIAN �1 M 4.a �O O N � ra tm (7N v V «+ O00r V � O p �1 O M 4A M H W o- E� ARC A. A��F * No. C2128 REN. / c 0 COMMERC I ASL GALCREEN MANDATORY MEA�5URE5 Date 2016 Scale Drawn Job Sheet on C C� Of Sheets C CN a 15K I FLU5H - - ' :•A'D TYPE 005 500 • �r AMP MAIN El LU65 :-- (N) Drawn OC l� V LU L PANEL TR Of Sheets LU 2 1/2 "G S..G iE) 5-4/0 CL LU X 4-55OMOM PANEL HG I 1-#4 GRD 1-#2 GRIT L _ -J #4 GROUND ROD 5-1/0 5-#I , -#6 GRD I-#6 GRIT (E) I 1/211G 11/2,10 (E) PANEL 3-#L 5-#I PANEL #1 1 -#& 'GRD 1-#6 GRD #`F CE) (FJ JIWW11800•52000 PANEL PANEL #2 #3 l I ins 1 1 t l its i 1 -,u r^ 1 t 1 _ml -120/20b MOUNTIN&: El FLU5H - - ' :•A'D TYPE 005 500 • �r AMP MAIN El LU65 :-- SHOWN Drawn OC l� V LU L 12300®�0 Of Sheets LU CL LU X JIWW11800•52000 • r 20b001560 POHER FACTOR 50% 2b&M l� Date 11/14/16 Scale SHOWN Drawn OC l� V LU L �I Of Sheets LU CL LU X Date 11/14/16 Scale SHOWN Drawn A5/JNT Job Sheet �I Of Sheets 481-011., y s r u n k _2 0 TYPICAL CHASSIS SUPPORT LOCATION 2 0 , f �w N (@ 6-6" O.C. SPACING MAXIMUM), ;a . fi E TP TP T » » Y TYPE 1 TIE DOWN » TYPICAL TIE DOWN TYPE ')2" CHASSIS -FRAME MEMBER WN TYPE TIE -DOWN TYPE 1 TYPICAL TIE DO 1 TYPICAL $Y OTHERS rl 5 DIA TENSION ENSION SLOTTED o , BOLT NU 1 i AL NUT, TYPICAL M , r PI TYPICAL TIE DOWN TYPE 2 TYPICAL CAL TIE DOWN TYPE P 2 Lill TYP. STEEL 4 .- PIER 'SUPPORT t -I 24"x24" PRESSURE -TREATED � ABES O:ANCHOR BY OTHERS 4 C T p LISTED AND APPROVED o OWN TYPE 2 TYPICAL TIED TYPICAL 2x12 DF PADS TYP C ) r� 0 4000 CAPACITY STEEL 2 C E PIERS BY OTHERS TYP. TP ; ( OTHERS), r � o , » » TYPICAL TIE DOWN TYPE 1 r� TIE OWN TYPE 1 .: TYPICAL D TYPICAL TIE. DOWN .TYPE. 'T' CORROSION PROTECTION BY OTHERS 4, V -0 1p TYPICAL TIE DOWNLOCATION ( 2 0_ 0 O.0 4f 0„r � _I ALL DIMENSIONS INCLUDING CHASSIS SPACING AND SUPPORT LOCATIONS SHALL BE TAKEN FROM ,► 4 _ 3 STEEL PIER DETAIL BESC ANCHOR 'DETAIL THE FINAL FOR CONSTRUCTION SET OF MODULAR DRAWINGS. SUPPORT PLAN DRAW/NGS ARE A OA IE DOWN LOCATIONS. NO SCALE NO SCALE GENERAL /N NATURE AND ONLY. REPRESENT SUPPORT SIZES AND T TP TP P VERTICAL AND LATERAL SUPPORT PLAN SCALE. 1/4”V-0" t �y / 2 k -3 i t r r ., 'HWw S r. 13, x:. vp GENERAL NOTES 13 �N GENERAL CHASSIS 'FRAME MEMBER BY OTHERS C AND ALL APPLICABLE LOCAL CODES. ALL WORK SHALL CONFORM TO THE 2013 BC N ----SNAP BUCKLE CHASSIS FRAME MEMBER SNAP BUCKLE (BY OTHERS) . .THE ENGINEER HAS PROVIDED AND IS RESPONSIBLE FOR SPECIFIC STRUCTURAL ITEMS ONLY, ALL OTHER REQUIREMENTS OF THE BUILDING CODE INCLUDING WATERPROOFING FIREPROOFING, DRAINAGE, HANDICAP ACCESSIBILITY, EGRESS REQUIREMENTS, PARKING, AND ALL OTHER DESIGN REQUIREMENTS NOT SPECIFICALLY SHOWN IN THE STRUCTURAL O D DESIGN CALCULATIONS ARE THE RESPONSIBILITY OF THE CONTRACTOR OR OWNER. SHOULD ANY CHANGES BE MADE • FRAME TIE DOWN STRAP AM DOWN A WITHOUT THE WRITTEN APPROVAL FROM THE ENGINEER THEN 45 t10 I 45 t10 FRAME .TIE W STRAP FROM THE DESIGN AS SPECIFIED IN THESE DOCUMENTS , 1 1 4 x .035 HOT DIP 4 x 035 HOT IP THE ENGINEER WILL ASSUME NO RESPONSIBILITY FOR ANY ELEMENT OR SYSTEM OF THE STRUCTURE. ( � ( 1 1 0 D GALVANIZED STEEL), T f TYP. GALVANIZED •STEEL), TYP.' THE DRAWINGS AND CALCULATIONS REPRESENT THE FINISHED STRUCTURE, AND, UNLESS SPECIFICALLY NOTED OTHERWISE, DO NOT SHOW THE METHOD OF CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR THE METHOD OF ABESCO ANCHOR PER 3/TP ABESCO ANCHOR PER 3/TP 'CONSTRUCTION AND SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE PUBLIC, CONSTRUCTION WORKERS, o 0 AND THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE FORMING, SHORING BRACING, SCAFFOLDING, ETC. r, ii I 1 IF A PARTICULAR FEATURE OF CONSTRUCTION IS NOT FULLY SHOWN ON THE DRAWINGS OR IN THE CALCULATIONS, '.THEN IT SHALL BE CONSTRUCTED IN THE SAME CHARACTER AS SIMILAR CONDITIONS THAT ARE SHOWN ON THE DESIGN DOCUMENTS. I (; D VERIFIED BY THE CONTRACTOR, AND ANY DISCREPANCIES MUST ANY CONDITIONS NOTED AS EXISTING MUST BE FIEL E , O PROCEEDING WITH CONSTRUCTION PRIOR TO THE BE BROUGHT TO THE ATTENTION OF THE ENGINEER WITHOUT REVIEW OF THE ENGINEER. OF THE CONTRACTOR OR ON ETC... IS THE RESPONSIBILITY ERPROOFING A AND FLASHING (ROOFS, FOUNDATIONS, ALL WATERPROOFING ) ( OWNER. 11 11 11 11 : TYPE 2 TIE DOWN DETAIL 2 1 'TYPE 1 TIE DOWN DETAIL SPECIAL INSPECTION: SPECIAL INSPECTION PER SECTION 1704 OF THE CBC SHALL BE PROVIDED FOR THE FOLLOWING TYPES OF CONSTRUCTION. NO SCALE TP NO SCALE TP E _ NONE REQUIRED Q !T THE SPECIAL INSPECTOR SHALL BE ACCEPTABLE TO THE ENGINEER OF RECORD B11 T7• AND BUILDING DEPARTMENT, SHALL BE ICBO QUALIFIED, AND THEIR EXPERIENCE F covNTy ply E� SHALL BE COMMENSURATE WITH THIS TYPE OF PROJECT. OP RSV MF 1 NT C E s 0 W E R D F V DAYS E C pMP� FOR ��Es /Z_ A N c NOTE. 2 E o_ SITE WORK/ FOUNDATIONS e y = PROVIDED) SOIL BEARING 1500 PSF NO SOILS REPORT P I ASSUMED MAXIMUM ( ) 1 MINIMUM DISTANCE FROM GROUND TO CHASSIS IS 12 AND 18 TO BOTTOM OF FLOOR JOIST- TYPICAL. ALL E FREE FROM DEBRIS VEGETATION FILL MATERIAL SH B , AND OTHER FOREIGN SUBSTANCES. DESIGN LOADS 2 ANCHORING EQUIPMENT SHALL BE CAPABLE OF MINIMUM ALLOWABLE WORKING LOADS OF 3150 LBS 16 A) THE STRUCTURE HAS BEEN DESIGNED FOR THE FOLLOWING CRITERIA PER CBC CHAPTER, SIONS I II III AND IV U.N.O.: 0 DIVISIONS AND BE CAPABLE OF RESISTING A I , , , A P SIS NG 50/ OVERLOAD. B SEISMIC: SEISMIC IMPORTANCE FACTOR: 1 • = 0.605 S1= 0.270 - E ACCELERATIONS: Ss L RESPONSE ACCEL R MAPPED SPECTA , 3 ALL PTDF WOOD SUPPORT PADS FOR THE STEEL PIERS SHALL BE PLACED CLASS: D _ ON STABLE SOILWITHAMINIMUM SEISMIC SITE SPECTRAL RESPONSE COEFFICIENTS: SDS = 05 31, SDI 0.335ALLOWABLE SOIL BEARING CAPACITY OF 1500 PSF. SEISMIC DESIGN CATEGORY: D _ _ WALLS BASIC SETS MIC FORC E RESTS TING SYSTEM. LIGHT FRAMED SHEAR SEISMIC BASE SHEAR: 1.71 KIPS i RESPONSE MODIFICATION FACTOR: R = 6.5 R 4 IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL DIMENSIONS (ACTUAL LENGTH AND WIDTH OF ANALYSIS PROCEDURE USED: EQUIVALENT STATIC FORCE PROCEDURE C) WIND: MODULAR AND CHASSIS SPACING/SUPPORT ORT LOCATIONS WHERE APPLICABLE BEFORE CONSTRUCTION BEGINS. WIND SPEED. 110 MPH WIND EXPOSURE: C 1 OPTION APPROVED - - ONE PLASTLC BEARING PADS MAY BE SUBSTITUTED ON A ONE-FOR-ONE D LIVE LOADS: 5 AT THE CONTRACTORS ) ROOF 20 PSF REDUCIBLE THE PE BASIS FOR SPECIFIED O S CII TDF. BEARING PADS 2411 x2411 BEARING MINIMUM). FLOOR 50 PSF Q ES S OF Ip M q O� F �l , C. J0 ti c� s z w 0 r� o. C 691 z rn 6 1 it <, �. � P Sl CV U 1 1 � q T � F OF L CA 11 1-710 1 THESE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE ONLY WITH THE ATTACHED STRUCTURAL CALCULATIONS 383 Rio Lindo Ave. Suite 200 Chico, CA 95926 P. 530.592.4407 SummitChico.com NORTH VALLEY BUILDING S'YSTEM'S O5/ LL i� J cc G Q W LU (D W C0 <1 0 z 1� � U O1 � �W Uj J J Q Q V U_ Q -0 a QW J 00 d' X fV W O REVISIONS: DATE: 11/07/16 SCALE: 1/4" =1'-0" DRAWN BY: ACJ JOB NUMBER: 16-262 SHEET: T P T i �� CONSTRUCTION LEGEND - SYMBOL DESCRIPTION MODEL/REMARKS DETAIL C P,AlO OR L 1 fS U . SEE E�OR� 3TRUC U A T 5 TE SE E R' P A URB PL , 4 OMES///// ENGIN/Ov// / I ING TRA F VNrRP OPLANTING AREA SEE PLANTING AND IRRIGATION PLANS XRIN ANL3 P / / Nv / G) RU D jPOST/ B P O MAT/ - ; 0 T I i L � ERLAY I O ATNE -010 )AX R L L I) QRED) COLORED Z�TEb 1 P N C B R,HEIGHTRE) / POST CCS T P W,1T O ,BARS, TEEL FQOT OOTLETS D. _ V�DSAiI�S NSP CO O 14 GALVANIZED TROUGH PLANTER 2'X8' OR X4' PLANTER GALVANIZED STEEL TROUGHS PLACED ON PRESSURE _ QUANTITY: 22 ( (2 'X8) ' 4 (2 X4) Q TREATED 4X4 POST. SEE PLANTING PLAN. 15 WOVEN - FRUIT BIN 4X4X3 TO PLANT TREES BY OWNER WATER PROOF INSIDE BIN AND LINE WITH FABRIC. SEE PLANTING PLAN. TING SH ,TREES j /RE/ I RD CT' 17 BASALT CHIP (3" THICK) (0-1 /4") CHIP COMPACTED IN WITH WATER/ROLLING �- 1$ I F N 7 ALL MET �L P D �Ck1T S l ET 19 RAIL ROAD TIES (LANDSCAPE TIES) TO BE PLACED WITH (3 PIPE PER TIE) 1" GALV. PIPE AT "- APPROXIMATELY 4' O.C. 'EXIS L,A P T , DR - 21 CIRCLE TROUGH PLANTER (4' DIAMETER) GALVANIZED STEEL TROUGHS. PLACED ON PRESSURE - QUANTITY: 4 TREATED 4X4 POST. SEE PLANTING PLAN. BY OTHERS BE//C 3 FOUN I U POj A T, THi 24 E RiCAL ER ECT. P LAN SIDE T -- T TE1 'FO I LE IT- O D IINS L D S O T S - E 26 - ORRU D OF T R 27 6" DRAIN PIPE 12" NDS DRAIN INLET WITH ATRIUM GRATE CONNECTED TO A 6" DUAL WALL HDPE DRAIN PLAIN END PIPE CONNECT TO _ EXISTING SIDE OF CATCH BASIN. ... BY OTHERS FAR MS _ CHURCHS TREET tj v, SHEET TITLE CTR ONS UCTi ON PLAN CONSTRUCTION ,. TE NO S 1. CONFIRM ALL LOCATIONS OF 'EXISTING UTILITIES WITHIN PROJECT SITE PRIOR TO EXCAVATION. THE , CONTRACTOR IS RESPONSIBLE F R TH C) E PROTECTION AND REPAIR OF DAMAGE TO ALL EXISTING UTILITIES.+« O DATES r 2. INSTALL ALL ELEMENTS PER MANUFACTURERS SPECIFICATIONS. _ Ill s%/ NO. DESCRIPTION SC ON DATE 9 f� 3. CONTRACTOR IS RESPONSIBLE TO COORDINATE � 1. BID SET 10/17/2016 O HIS WORK WITH THE WORK OF OTHERS. F C N O T Ty 2. .: 4. MAINTAIN ENGINEER'S DESIGNED MINIMUM 2/ ' SLOPE AWAY FROM BUILDING. IF DURING THE 00— V, �F / F F w V F L O s.COURSE F LANDSCAPE CONSTRUCTION THE 2/ROUGH GRADE AWAY FROM BUILDING DESIGNED _ AND ESTABLISHED BY OTHERS IS DISTURBED, A 4. IT IS THE RESPONSIBILITY OF THE LANDSCAPE CONTRACTOR </ � -: ZO fir' /C ' F , C « TO REESTABLISH THISRADE PER 1 ,. G INTENT OF CIVIL E CS C ENGINEER. REFER TO CIVIL ENGINEER'S PLANS. F �. <-B Y 5 CONTRACTOR SHALL OBSERVE ALL SAFETY REGULATIONS PERTAINING TO THIS PROJECT. 6. 7- 6. ANY CHANGES SHALL BE APPROVED BY THE LANDSCAPE ARCHITECT PRI R T O O CONSTRUCTION. 8. 7. ALL VEGETATION,T P TOP. AND OTHER N O UNSUITABLE TABLE MATERIAL IN AREA F S O FOUNDATIONS AND PLOT LAB HALL O DATE. 10/17/2016 CONCRETE SLABS S BE REMOVED FROM CONSTRUCTION AREA. 8. INSTALL CHRISTYPLA HBL S S OC KSORE AL ALL ( EQUAL) AT RAINWATER DOWNSPOUTS UNLESS RAINWATER DOWNSPOUTS I OU S ARE TED DIRECTLY INTO THE STORMDRAIN SYSTEM. PROJECT NUMBERS 9. SEE DETAILS AND SPECIFICATIONS FOR ADDITIONAL INFORMATION. MELTON DESIGN GROUP- 2211.2 CONSULTANT # PROJECT : F R O E Y DER R U o N G OUND - SHEET NUMBER � p G Q- O SERVICE o �ALERT. ... of Northern California a NORTH Call: TOLL FREE _800 22.7 2600 _ 0 20 40 TWO WORKING DA O NG YS BEFORE YOU DIG ; SHEET ` OF C O MELTON DESIGN R P OGROUP COPYRIGHT 2011 I I !I --_ -- - � �� __ I _ ., _. i i