General Construction Notes
1. All walls 2x4 @ 16" o.c. Wall height 8'
2. All concrete 2500psi min.
3. Fire rated door at garage/utility location
4. 5/8" sheetrock on garage wall and ceiling
5. 1/2" sheetrock on interior brace wall nail
w/1 V2 nail @ 7" o.c. edge and field (as indicated)
6. 7/16" OSB exterior shear shear, nail w8d
@ 6" edge and 12 field (as indicated)
7. Wood trusses as 24" o.c,
8. Wood stove approved and installed by EPA standards
9. All windows to be doubled glazed and Low -E
replace all existing windows
10. 22"x30"Attic access in hallway of addition
11. Garage floor to be sloped toward doorway to
facilitate flow of liquids to exterior r-
12. HVAC to be installed in closet in existing section
13. Smoke alarms to be installed in all sleeping areas and
all adjoining areas hardwired with battery backup to
comply with UL217
14. Carbon Monoxide alarms in hallway by bedrooms
to comply with UL2034
15. Finished grade to be a min, slope of 6" in 10'
16. All framing lumber to be DF #2 unless indicated otherwise
17. Top plates to have overlap of min 4' with (8) 16d nails
on each side of splice
18. Attic and underfloor ventilation shall be at the ratio of 1/150
All vents to have min opening of 1/16" and max of 1/8" of non-
combustible material
Eave vents shall comply with 2013 CRC R327.6.3 and Clable
vents to comply with 2013 CRC R327.6.2 (/ </ S 3 11 V 1'g
Total attic NFAV area required is 1106 sq.in.
Underfloor vents to be install within 3' of each corner with a total
NFAV area of 600 sq. in. �F) 1.2-"
19. Bathroom fans shall be capable of exhausting 50 cfm and be
controlled with a humidistat control capable of adjustment
between a relative humitity range of 50%-80%
20. Area:
Living -680 sq.ft.
Garage -472
Porch ----160
Total area: 1,312 sq.ft.
"/-I- A, v
4 Re.
�- 6 ''-�I
� Soil
++ M
PERMIT # �'"` ~ 266
BUTTE COUNTY DEVELOPMENT SERVICES
REVIEWED FOR
CODE COMPLIANCE
DATE -2 02 - ll BY
Foundation Notes
1. All concrete min. of 2500 PSI
2. Drill and epoxy all rebar where attaching
to existing foundation
3. Y2 x12 A.B. Max of 6'0.C.
4. V2 " rebar at bottom and top of all foundation
with 3" clear of all earth contact
5. Footer and wall to be poured monolithic
Tru-Bilt
Construction & Drafting
Pro j ect
JS ),',1
/firTitle
�� � � ,,:•(.rv,;��.�
Date
Sheet
Scale
Beam
t7-y?�'
Tos-r
PERMIT # /T/b Z 6 `6 7
BUTTE COUNTY DEVELOPMENT SERVICES
REVIEWED FOR
CODE COMPLIANCE
DATE—A 2 -/l BY
Floor Framing Notes
1. 9 VM -1_210_' (or equal) Floor Joist @ 19.2" O.C.
2. 2x6 DF joist in utility room
3. 4x8 DF Floor beam
4. Solid blocking between all joist @ beam locations
5. Solid rim joist at all wall locations
6. Nail "I" joist to wall and beam w/16d
7. All sill plates in contact with concrete to be
preasure treated
8. 1/2x12" A.B. at maximum spacing of 6' with
min. of 2 per sill, within 12" of each endof plate
9. A 3x3x0.229 washer at each A.B.
PERMIT #49�
BUTTE COUNTY DEVELOPMENT SERVICES
REVIEWED FOR
CODE COMPLIANCE
_��_ �17...BY24��
DATE _
A
4-v it,5 -s &&,yi e -'e- 0� 'T (Ole en C
Roof Framing Notes
1. Typical design loads:
D.L.= 15 PSF
L.L.= 20 PSF
2. Roof pitch 4/12 +/- (to be confirmed)
3. Garage door header, 4x12 DF #1
4. Porch beams,, 4x10 DF #2
5.- All door and window headers, 4x6 DF #2
6. Freize blocks at all wall location, nail into truss
and wall w/ (2) 16d and nail sheathing into block
with (3) 8d
7. "H -l" Ties at end of all trusses
8. Headers less -than 6' single trimmer, over 6' double trimmer
9. Solid sheathing under all valley trusses with blocking
attached to roof to prevent sliding of valley trusses
Propane Water Heater Notes
Seismic bracing shall be provided at 1/3 locations from top and bottom of
unit w/ a min. of 4" above the controls
A pressure relief valve to be install with pipe drainage to exterior of bldg
that trminates at 6"-24" above the ground level
Heater must have a gas shutoff valve
A type `B" vent shall be used to exhaust the fumes to exterior above roof
The propane piping to be grounded to general ground and sized for the
required BTU of unit
A 120V receptacle to be within 3' of unit
Unit to be elevated,2'' above garage floor
1,.e- 3.6,t /�ql:r. ®f aoo o0o 7/ V
/occi 11e-cl (f
wa �� $icaK
PERMIT # a (_ + %
BUTTE COUNTY
RSERVICES
REVIEWED FOR
CODE COMPLIANCE
DATE
Additional Electrical Notes
The subpanel shall be supplied from the main existing panel
as indicated on Sht.#8 and be grounded to new ufer ground
All fixtures, ceiling fans, lamp holders and receptacle outlets
shall be securely supported in compliance with 2013 CEC
ELECTRICAL OUTLET NOTES:
ARC FAULT CIRCUIT -INTERRUPTER TO BE INSTALLED ON ALL 15 - 20 AMP, 120V, 1 CIRCUITS PER
210-12 OF THE 2013 CEC.
ALL WIRE SHALL BE INSTALLED IN WALL STUD BAYS OR ATTIC WHEN POSSIBLE
ONLY SPECIAL OUTLETS HAVE BEEN DEPICTED ON THIS PLAN. GENERAL CONVENIENCE OUTLETS SHALL
BE INSTALLED SO THAT NO POINT ON ANY WALL IS MORE THAN 6'-0" AWAY FROM ANY OUTLET. THIS
APPLIES TO ANY WALL OVER 2'-0" IN LENGTH. FOR ADDITIONAL INFORMATION SEE ARTICLE 210-52 OF THE
2013 CALIFORNIA ELECTRICAL CODE
ALL OUTDOOR'OUTLETS SHALL BEPROVIDED WITH G.F.I. PROTECTION IN COMPLIANCE WITH CALIFORNIA
ELECTRICAL CODE.
ALL WIRE SHALL BE 12 GA. COPPER. INSTALL ALL WIRE ON 20 AMP CIRCUIT WITH MAXIMUM NUMBER OF
OUTLETS ON ANY GIVEN CIRCUIT NOT TO EXCEED 12.
SPECIAL APPLIANCES ARE SHOWN WITH A SINGLE OUTLET SYMBOL AND SHALL BE SERVED BY A
DEDICATED CIRCUIT.
ALL ELECTRICAL BOXES SHALL BE PLASTIC NAIL ON TYPE. IF THE CONTRACTOR CHOOSES TO USE
METAL BOXES FOR A SPECIFIC LOCATION, THE BOX SHALL BE GROUNDED IN COMPLIANCE WITH THE
C.E.C.
PROVIDE 1 1/4" P.V.C. CONDUIT STUBBED THROUGH THE PLATE LINE & ATTACHED TO A ROOF RAFTER FOR
ALL LOW VOLTAGE OUTLETS (PHONE & TV)
TWO OR MORE 20 -AMPERE SMALL APPLIANCE BRANCH CIRCUITS SHALL BE EVENLY PROPORTIONED IN
THE KITCHEN, PANTRY, BREAKFAST ROOM OR SIMILAR AREAS TO SEVERE ALL WALL AND FLOOR
RECEPTACLE OUTLETS. SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS.
LAUNDRY ROOM RECEPTACLE OUTLETS SHALLE BE SUPPLIED BY AT LEAST ONE 20 -AMPERE BRANCH
CIRCUIT. SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS
PERMANENTLY INSTALLED LUMINAIRES IN KITCHENS SHALL BE HIGH EFFICACY LUMINAIRES. UP TO 50%
OF THE WATTAGE, AS DETERMINED IN 2013 CALIFORNIA ENERGY CODE, SECTION 150(k)8 & TABLE 150-C,
OF PERMANENTLY INSTALLED LUMINAIRES IN KITCHENS MAY BE IN LUMINAIRES THAT ARE NOT HIGH
EFFICACY LUMINAIRES, PROVIDED THAT THESE LUMINAIRES ARE CONTROLLED BY SWITCHES SEPARATE
FROM THOSE CONTROLLING THE HIGH EFFICACY LUMINAIRES.
BATHROOMS TO HAVE MINIMUM OF (1) HIGH EFFICACY LUMINAIRE ON ANY SWITCH, ANY LOW EFFICACY
LUMINAIRES TO BE ON A VACANCY SENSOR.
LAUNDRY ROOM, GARAGES AND UTILITY ROOMS TO HAVE BOTH HIGH EFFICACY LUMINAIRES AND
VACANCY SENSORS.
LIGHTING IN INTERIOR COMMON AREAS MUST HAVE HIGH EFFICACY LUMINAIRES OR ON A VACANCY
x SENSOR IF LESS THAN 20% OF BUILDING AREA. IF BUILDING HAS MORE THAN 20% COMMON AREA IT IS
TREATED AS NON-RESIDENTIAL.
NEW RECESSED LIGHT FIXTURES MUST BE AT/IC RATED
LUMINAIRES PROVIDING OUTDOOR LIGHTING AND PERMANENTLY MOUNTED TO A RESIDENTIAL BUILDING
OR TO OTHER BULDINGS ON THE SAME LOT SHALL BE HIGH EFFICACY LUMINAIRES OR CONTROLLED BY
ONE OF THE FOLLOWING:
1) CONTROLLED BY MANUAL ON/OFF SWITCH AND,
2) A MOTION SENSOR THAT IS NOT EQUIPPED WITH AN OVERRIDE OR BY PASS SWITCH THAT DISABLES
THE MOTION SENSOR AND ONE OF THE FOLLOWING THREE METHODS TO AUTOMATICALLY TURN THE
LIGHTS OFF DURING THE DAY:
a) PHOTO CONTROL NOT HAVING AN OVERRIDE OR BYPASS SWITCH THAT DISABLES THE PHOTO
CONTROL; OR
b) aSTRONOMICAL TIME CLOCK NOT HAVING AN OVERRIDE OR BYPASS SWITCH THAT DISABLE THE
ASTRONOMICAL TIME CLOCK; OR
c) ENERGY MANAGEMENT CONTROLL SYSTEM (FMCS) NOT HAVING AN OVERRIDE OR BYPASS SWITCH
THAT ALLOWS THE LUMINAIRE TO BE ALWAYS ON.
THESE LUMINAIRES ARE AS INDICATED IN THE 2013 CALIFORNIA ENERGY CODE 150(k)13 (NOT INCLUDING
LIGHTING AROUND SWIMMING POOLS/WATER FEATURES OR OTHER ARTICLE 680 LOCATIONS) OR ARE
CONTROLLED BY OCCUPANT SENSORS WITH INTEGRAL PHOTO CONTROL CERTIFIED TO COMPLY WITH
SECTION 119(d).
ALL EXISTING PLUMBING FIXTURES SHALL COMPLY OR BE REPLACED WITH NEW FIXTURES COMPLYING
WITH CAL GREEN RESIDENTIAL MANDATORY MEASURES SECTION 4.3.
0 P ct seg- s
Scale 4 if, l
Sheet
PD-�)o
E- Y, i5 1 n5
Xe .I 'Ra p�,—,T
k�
09 i
A r 1 'thud
0,4 Is
tt
Vett u tie ci`
C%vclr
PERMIT # ,8/6 6 6 ?
BUTTE REVIEWED FOR SERVICES
CODE COMPLIANCE
DATE ?-.2-1,7 eY
vater:"shall,t
sLjrfac e '.
'W
lbt limit
ed
:V'F
.4
'3�:shall betletermiriew uy ciassiTying,:inp-.,,c P
DaUr) q -t
kAJQUI 1. 9L W W�5AI6
ork)dirg uIpMent emationally orlregic
.�o - raiq- recognizea Training, or cemication prograrn umeruli
S;: ��atbnaFji d
t irect s6be�h�and rpsO"� iV.o a:-Wso.n train :� a
fried I�J6 -dl
"P.pn I I may perfbimi",,.H AG Vistalla whe
v IPPS':: � �,
bf
, id:� i :'p spry
mix., ense mples- 8 el�
fac or:� d 6';irl� bf ejocept 61 HVAC
tho respo ll�H��:'4stern6n,.Orcont' t '50
s a aO'P
ran h 11
an:(x -.o..rna_ h,�, jea ge;
, t Jhfbmia'Ak�: esoUr' '.'86atd
. . . I I , -.;.�7 ''' *' ' " '' b;�� 30. qO4� I . ducts and eq
hd Wi�lt 4-
1071b(the'2007"Ca 8 ces.,
i6ris 4'�i, 4.36 idi red to
rates. fl.'Ji � .-':. '
'N
di sal,� ferns m r rid� - HAI, onflatt Qr.:N , �flat E�
later dol E�Ct bd:.!4nd. ispo
-A. nr'nFnai S� and -Coathas Prod fe�W-Wmm,
mrj%a&,J n!%ln#a:2nd:mv0lna - Ap.r int
S
U - .
: I,. I ,fc
I - X �. , �A:x":6 :sfiall 1 -Ihted MIA Li�
DIN)