HomeMy WebLinkAboutB16-2716 039-060-077BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES INSPECTION CARD MUST BE ON JOB SITE 24 Hour Inspection Line (IVR) : 530.538.4365 (Cut off time for inspections is 3pm) Development Services cannot guarantee inspections on the date requested Office: 530.538.7601 Fax:530.538.7785 www.ButteCountv.net/dds Permit No: B16-2716 Issued: 12/7/2016 APN: 039-060-077 Address: 2683 HEGAN LN, CHICO Owner: TAYLOR GORDON P & LINDA M Permit Type: SOLAR ROOF -RES Description: Roof mount solar .'I AREA 5 Flood Zone: None SRA Area: No SETBACKS for Zon*no- AG_ SRA_ P Front: Centerline of Road: Rear: SRA:, Street: AG: Interior Total Setback from Centerline of Road: ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING Inspection Type IVR INSP DATE Setbacks 131 Foundations / Footings 111 Pier/Column Footings 122 Eufer Ground 216 Masonry Grout 120 Setbacks 131 Do Not Pour Concrete Until Above are Signed Pre -Slab 124 Gas Test Underground/floor 404 Gas Piping Underground/floor 403 -Underfloor Framing 149 Underfloor Ducts 319 Shear Transfer 136 Under Floor Plumbing 412 Under Slab Plumbing 411 Blockin nde inin 612 Tiedown/Soft Set System 611 Do Not Install Floor Sheathing or Slab Until Above Signed Shearwall/B.W.P.-Interior 134 ShearwallB. W.P.-Exterior . 135 Roof Nail/Drag Trusses 129 417 Manometer Test Do Not Install Siding/Stucco or Roofing Until Above Signed Rough Framing 153 Rough Plumbing 406 Rough Mechanical 316 Rough Electrical 208 4 -Way Rough Framing 128 Gas Piping House 403 Gas Test House 404 Shower Pan/Tub Test 408 Do Not Insulate Until Above Signed i - Inspection Type IVR INSP DATE T -Bar Ceiling 145 Stucco Lath 142 Plumbing Final 813 Fire Sprinkler Test or Final 702 Swimming Pools Setbacks 131 Pool Plumbing Test 504 Gas Test 404 Pre-Gunite 506 Pre -Deck 505 Pool Fencing/Alarms/Barriers 1 503 Pre -Plaster 507 - Manufactured Homes Setbacks 131 Blockin nde inin 612 Tiedown/Soft Set System 611 Permanent Foundation System 613 Underground Electric 218 Sewer 407 Underground Water 417 Manometer Test 605 Continuity Test 602 Skirting/Steps/Landings 610 Coach Info Manufactures Name: Date of Manufacture: Model Name/Number: Serial Numbers: Length x Width: Insignia: K• R.� t,: ?: " � % : 3a <.sja FiiBaly r. t .77 Permit Final 802 Electrical Final 803 Mechanical Final 809 Plumbing Final 813 Fire Sprinkler Test or Final 702 Public Works Final 538.7681 Fire De artment/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final **PROJECT FINAL -21 *Project Final is a Certificate of Occupancy for (Residential Only) PERMITS BECOME NULL AND VOID 1 YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A 1 YEAR RENEWAL 30 DAYS PRIOR TO EXPIRATION l r REC G ,.{ .��� • TANINPEAK kr_ REC TwinPeak Series solar panels feature an SERIES innovative design with hi;h panel efficiency �"- " and power output, enabling customers to get r PREMIUM SOLAR PANELS WITH SUPERIOR PERFORMANCE REC TwinPeak Series solar panels feature an innovative design with hi;h panel efficiency �"- " and power output, enabling customers to get .'�N-11 the most out of the spat? used for the installation. ` <<, Combined with industry -reading product ,= quality and the reliabilityof a strong and ` r established European brand, REC TwinPeak panels are ideal for resid=ntial and commercial ' s., •' ` rooftops worldwide. I�il�illl�V-11 lop MOREPOWER IMPROVEDPERFORMANCE OUTPUT PER M' IN SHADED CONDITIONS y FID FREE "y 100% REDUCES BALANCE OF PID FREE SYSTEM COSTS I REC T.WINPEAK, SERIES ,', 900 382.5 o--11 v 900. T ow Mountingholes ' u, - 1130.2 - _ � o 1� r i 1200 r p EFFICIENCY Q YEAR PRODUCT WARRANTY YEAR LINEAR POWER OUTPUT 25 WARRANTY Nominal operating cell temperature (NOCT) 44.6°C (t2°C) Temperature coefficient ofPmpp-0.39%/'C Temperature coefficient ofVoc -0.31%/°C Temperature coefficient of Isc 0.045 %/°C Celltype: 120 REC HC multi -crystalline Measuenercsinrtm 1 I I Glass: ELECTRICAL DATA@ STC / Nominal Power -PMPP(Wp) REC265TP REC270TP 265 270 '" 275 r Watt Class Sorting -(W) 0/+5 0/+5 0/+5 Nominal Power Voltage - VM, (V) 30.9 31.2 31.5 NominalPowerCurrent-IM,(A) 8.59 8.67 8.74 Open Circuit Voltage -VaIV) 37.7 38.0 38.3 Short Circuit Current- Isc(A) 9.21 9.29 9.38 Panel Efficiency(%) ,_... 16.1 16.4 16.7 _ ._ __ .,,............ w...,,,.... .... .__. ._. .. _..,........... Analysed data demonstrates that 99.7% of modules produced have current and voltage tolerance of:3%from nominal values. .. Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/ms, cell temperature 25'C). • Atlowirradianceof200W/m'(AM 1.5and cell temperature 25'C)atleast 94%ofthe STC module efficiency will beachieved. ELECTRICAL DATA . NOCT Nominal Power -Pmpp(Wp) REC26STP REC270TP 202 207 1 210 ._...___..._............ ..... ...... .,..... _ Nominal Power Voltage -Vm,IV) _.. _., ..,_... ...., ._.;.. . . .... ......... ...._ ...._.. 29.4 29.7 ... . 29.9 Nominal Power Current- I,,,(A) 6.9 6.96 7.02 0 enCircuitVolta e- Va V Open g () 36.0 36.3 37.0 s' rtC ... ..... _...:_..__ ShorcuitCurrent --I'Isc (A) .-.._.._.. _,.._. ......... �,.., ...,_..... 7.3 7.37. 7.43 _ Nominal operatingcell temperature NOCT (80O W/m', AM 15, windspeed I m/s, ambient temperature 20'C). 1 �ECERTIFICATIONS 01 -us t MECHANICAL DATA 10 year productwarranty P C pyE 25 year linear power outputwarranty Area: IEC 61215, IEC 61730 & UL I703 (max. degress ion in performs nce�of 0.7% p.a.) IEC 61701(SaltMist-severity level l) See warranty conditions for further details. Notel Specifications subject to change without notice. take gvay p EFFICIENCY Q YEAR PRODUCT WARRANTY YEAR LINEAR POWER OUTPUT 25 WARRANTY Nominal operating cell temperature (NOCT) 44.6°C (t2°C) Temperature coefficient ofPmpp-0.39%/'C Temperature coefficient ofVoc -0.31%/°C Temperature coefficient of Isc 0.045 %/°C Celltype: 120 REC HC multi -crystalline 6 strings of 20 cells (156 x 78 mm) Glass: 3.2 mm solar glass with anti -reflective surface treatment Backsheet: Double layer highly resistant polyester Frame: Anodized aluminum (silver) Junction box: 3 -part with bypass diodes IP67 rated 4 mm2 solar cable, 0.9 m +1.2 m Connectors: Multi -Contact MC4 (4 mm2) Origin: Made in Singapore 0 c MAXIMUM RATINGS Operational temperature: -40 ... +85°C Maximum system voltage: 1000V Maximum snow load: 550 kg/m2 (5400 Pa) LL Maximum wind load: 244 kg/m2 (2400 Pa) L Max series fuse rating: 25A Max reverse current: 25A t MECHANICAL DATA P C Dimensions: 1665 x991 x38 mm Area: 1.65 m2 Weight: 18 kg CP Notel Specifications subject to change without notice. CP 1r for an easy way take-e-wayWEEE Compliant _ Recyclingscheme 1 REC is a leading global provider of solar energy solutions. With more than 15 years of experience, we offer sustainable, high performing products, services and investments for the solar industry. Together with our partners, we create value by providing solutions that better meet the world's growing energy needs. REC is headquartered in Norway and listed on the Oslo Stock Exchange (ticker: RECSOL). Our 1,800 employees worldwide generated revenues of USD 680 million in 2014. Q,IRCC www.recgroup.com Mounting systems for soIar.techn.ofogy, • : � ,. ' `�- � . • , •solar system ~ t ' �,� ,• , .+�- "rte �r • • / .' r •..: yam,- , +' CROSSRAIL MAIN COMPONENTS . "h" f a CROSSRAIL ACCESORIES - r• ^ _r ' ,- Below are the parts to assemble the Everest Crossitail_system •• • 1 c ` a rr + ` 4 -• ' - CrossRail 48" - �' • µ • r Enphase 215 Mounting Kit X - CrossRail Material: Aluminium u - e - ./ A • Material: Aluminium ` - el.a2 Length: 161.42- - L-Foot L -foot w/ T -Bolt and Flange Nut (CR 48), - L-Foct Material: End Cap for CrossRail 48 Material: glass fibre reinforced polyamid • ,. Hardware Stainless Steel - .. 5 M IOl: _ .. TBoF. 28/15 M70 . • t . Hex Flange Nut• Serrated M 10 Rail Connector Set CrossRail 48 , Omega Wire Management Clip r • L Material: Aluminium Splice - - Material: polyamid, black • j • H_: Stainless Steel je 'If • - Burndy WEEB Lug 8.0 ' Module End Clamp Set y, • - Material: aluminium ' Material. Aluminium Clamp ' . . _ _ a . • �" Hardware: Stainless Steel y •.. 4 r y y Burndy WEEB Lug 8.0 Hardware Only F t - - - ... _ _ Material: Stainless Steel - •( Module Middle Clamp Set For artching Burndy WEEB Lug 8.0 to CrossRail 48 1B411 28115 M20 Material: Aluminium - • - _ Hex Flange Net, Serrated 20 . . - Hardware: Stainless Steel •. r 'x Burndy KMC WEEB Clip, T ` • • Dark Module End Clamp Set ,�i..+r� Material: Stainless Steel Use with Everest Mid Clamps to Bond Modules to the CrossRail 48 • ' Maternal. aluminium • i ' . T } Dark Module Middle Clamp Set • t • - Material: aluminium • .. - r .. ri T` C �� .,lam'` ;"W. •Air. e s ` ' ,� ,i 'r t, � � .c � , • r . �y�,�, - F ' EVEREST SOLAR SYSTEMS CROSSRAIL' PITCHED ROOF -SOLUTION ` ASSEMBLY: STEP BY STEP r- 40 ® ROOF ATTACHMENT / FLASHING' \ �` ® ATTACH MODULES WITH END CLAMPS Install the appropriate roof attachments and flas- " Everest Solar supplies End Clamps preassembled hings according tothe manufactures installation ins- with the universal MK2 Slot Nut for fast, easy ins - p • tructions (e.g. Quickmount PV Composition mount). tallation. To attch the End Clamps to the CrossRail, Ensure the waterproofness of the roof observing all t K2 Slot Nut into the CrossRail 48 by M applicable laws, regulations, ordinances and codes. R� pulling insert the he M the plastic tab then rotating clockwise Ensure that the structiral roof attachments points by 90 degrees. are in the right position according to your structural \ calculations for the CrossRail system. ys Never mount end clamps directly on the rail joint or Materials required: appropriate roof attachments i end of the rail I There must be at least 1 " (20 mm) and flashings . from end clamp to the end of the rail. e ' Attach modules and position the clamps on the mo - 1 dule according to the manufacturer's instructions. L -FOOT TO ROOF ATTACHMENT The Contractor shall verify that the mounting e ® ructions of the module manufacturer are followed! ed! e Place the L -Foot on top of the roof attachment Module End Clamp Tightening Torque', 10.3 Ibf-ft with - the long leg of the foot facing the roof ridge. Tighten (14 Nm)." the hardware (e.g. bolt and nut) according to the manufacturer's instructions through hole on the . Materials required: End Clamp Set bottom flange of the L -Foot. , Materials required: Everest L -Foot, attachment , ® ATTACH MODULES WITH MIDDLE hardware by 3rd party roof attachment supplier. CLAMPS Everest Solar supplies Mid Clamps preassembled . ®® with the universal MK2 Slot Nut for fast, easy ins- tallation. To attch the Mid Clamps to the CrossRail, ATTACH CROSSRAIL 48 TO THE L -FOOT ® insert the MK2 Slot Nut into the CrossRail 48 by ' pulling up on the plastic tab then rotating clockwise Place the CrossRail on the high side of the L -Foot by 90 degrees. ( _ facing the roof ridge. Insert the T -Bolt through Attach modules and position the clamps on the mo - the L -Foot slot and into the lateral channel of the dule according to the manufacturer's instructions. CrossRail 48. Turn the T -Bolt clockwise making sure The Contractor shall verify that the mounting inst- that the groove mark on the end of the T -bolt is ;���,® ructions of the module manufacturer are followed! verticle. Put the appropriate self-locking Hex Flange , Nut onto the T -Bolt, adjust the height of the rail Module Mid Clamp Tightening Torque; 10.3 Ibf-ft 'and tighten the nut with a torque wrench using a (14 Nm). torque 25.8lbf-ft (35Nm) for M10. Ensure that the Materials required: Middle Clamp Set top of the Crossitail 48 is located above the top of the L -Foot. Verify that the groove mark on the end - the T - Bolt is verticle, otherwise disassemble and ` ® OPTIONAL: END CAP ASSEMBLY repeat this step. Due to thermal expansion, we recommend a ther- Push the pins of the CrossRal 48 end cap into end mal break after (20 m), but no further than (24.4 - \ of the rail. m). The minimum separation between the two rails " " is 1.25to 2 (3-5 cm)."' - Materials required: CrossRail 48 End Cap Materials required: CrossRail 48, T -Bolt MIO, self- ' locking nut M10 - �) tM RAIL CONNECTOR ASSEMBLY 'Align the two rail ends next to each other (Rail Joint). Slide the Rail Connector on to the rails from below aligning the middle of the Rail Connector near the Rail Joint. Connect the Rail Connector to each rail using 2 T -bolts, 4 T -Bolts total, and 4 self-locking nuts. The rail joint may not be in the range of the L -Foot or roof attachment. Tightening torque: 25.8 Ibf-ft (35Nm) for M 10 hardware. Materials required: Rail Connector Set (includes hardware) ' A The Cr6ssRail System is simple and fast to install. Please contact us for further assistance: SERVICE -HOTLINE +1 760.301.5300 ACCESSORY ASSEMBLY r 1 - i Everest Solar Systems, LLC 3809 Ocean Ranch Blvd. 2 Suite 111 Oceanside, CA 92056 Tel. +1.760.301.5300 ihfo@everest-solarsystems.com www.everest-solarsystems.com .r ENPHASE 215 MOUNTING KIT Everest Solar supplies the preassembled hardware to attach the Enphase 215 with the universal MK2 Slot Nut for fast, easy installation. To attch the en - phase mounting kit to the CrossRail, insert the MK2 Slot Nut into the CrossRail 48 by pulling up on the plastic tab then rotating clockwise by 90 degrees. Materials required: Enphase Mounting Kit Optional: Burndy KMC WEEB Clip OMEGA WIRE MANAGEMENT CLIP Install the Omega Wire management clip to the CrossRail 48 by pinchingthe end of the dip and inserting the ends into the side c -channel slot of the CrossRail 48. O—ftfl Totl I.Jrn PB I US] 10213 r•ndn i,."ue la A�svao-e ry,r oftSprofw,uaro ar aa�ect is d,nrxF ";mw,mote.a,an ofMpredu 00oeamieaioE-15axsyi—rertrna 1 _a Uo,a,.4.&g MeeAeive I'mm Wxrnn.w forth 0.6.. "I soorSei Wohi , Op. tlr4troNairil, 14.tion , NDY Washer, Electrical Equipment Bond ..WEEB INSTALLATION INSTRUCTIONS For Everest Solar CrossRail 36 and CrossRail 48 Mounting Systems Only Please read carefully before installing. Burndy LLC recommends that the sufficient details of the installation be submitted to the AHJ for approval before any work is started. WEEB-KMC WEER -LUG -8.0 _ Products are tested to UL 467, CAN/CSA-C22:2 No. 41 cMus US/ Canadian standards for safety grounding and bonding equipment. Intertek 3098177 Document Number 104-0404-000104-000 w I l e Lj © 2012 BURNDY LLC. HUBBELL Page 1 of 6 ' WEEP COMPATIBILITY The WEEB family of products can be used to bond anodized aluminum, galvanized steel, steel and other electrically conductive metal structures. All installations shall be in accordance with NEC requirements in the USA and with CSA C22.1 in. Canada. The WEEBs are for use with modules that have a maximum fuse rating of less than 25A. Certain module frames do not have enough structural strength to withstand the force required to embed a WEER. These frames will deform and therefore not allow sufficient penetration of the WEEB teeth. The general requirements for minimum module frame thickness of "boxed" type module frames are illustrated below. For more information regarding module compatibility, please see the technical documents section of our website. Everest Sol Mid Clan Anodized aluminum PV module frame i Everest Solai Slot Nut with Clir Nolte: ..e% l Cap Screw :ed Washer ;ion Spring O LESS THAN 3.00 mm O GREATER THAN 8.50 mm NO THINNER THAN 1.50 mm IL Inspect each module frame used with a WEEB to ensure that the bottom mounting face of the' frame is flat, and that there are no hindrances to embedding. WEEB teeth. Do not use a module with a frame that prevents -the WEEB teeth from embedding fully. Document Number 104-0404-000104-000 W I L e y © 2012 BURNDY LLC. W" BURNDY' Page 2 of 6 SYSTEM OVERVIEW OF EVEREST SOLAR SYSTEM USING CROSSRAIL 36 When position of solar modules is finalized, torque fasteners to 12ft-Ib/16.3N-m using Penetrox'A on threads. Assemble WEEB-LUG-8.0 assembly using M8 T -Bolt and Flange Nut. Torque fasteners to 10ft-Ib/13.5N-m using Penetrox-A on threads. Lay in equipment ground conductor and torque bolt to 7ft-Ib / 10N -m Important notes: 1. Use general purpose anti -seize compound on fastener threads when installing WEEBs. 2. The NEC section 690.43 states "Exposed non-current carrying metal parts of module frames, equipment, and conductor enclosures shall be grounded in accordance with 250.134 or 250.136(A) regardless of voltage". 3. WEEBs are intended for SINGLE USE ONLY. Functionality will not be guaranteed if reused. W L - Document Number 104-0404-000104-000 © 2012 BURNDY LLC. BURNDY' Page 3 of 6 SYSTEM OVERVIEW OF. EVEREST SOLAR SYSTEM USING CROSSRAIL 48 When position of solar modules is finalized, torque fasteners to 12ft-Ib/16.3N-m using Penetrox-A on threads. Assemble WEEB-LUG-8.0 assembly using M8 T -Bolt (with an M10 T -Bolt Head) and Flange Nut. Torque fasteners to 10ft-Ib/13.5N-m using Penetrox-A on threads. Lay in equipment. , L�,j ground conductor and ..ue bolt to JI _j& L ' I Important notes: 1. Use general purpose anti -seize compound on fastener threads when installing WEEBs. 2. The NEC section 690.43 states "Exposed non-current carrying metal parts of module frames, equipment, and conductor enclosures shall be grounded in accordance with 250.134 or 250.136(A) regardless of voltage". 3. WEEBs are intended for SINGLE USE ONLY. Functionality will not be guaranteed if reused. Document Number 104-0404-000104-000 W I L eLi © 2012 BURNDY LLC. BURNDY' Page 4 of 6 WEEB-KMC LAYOUT ' EVEN NUMBER OF MODULES IN ROW ' X DENOTES PLACES TO INSTALL WEEB-KMC C X R = 4 X 1 WEEB-KMC NEEDED = C X R'= 4 X 1= 4 ODD NUMBER OF MODULES IN ROW X DENOTES PLACES TO INSTALL WEEB-KMC C X R = 5 X 1 WEEB-KMC NEEDED = [C +1] X R— [5+1] X 1 = 6 Note: When replacing a single faulty module, also remove the adjacent module which contacts the same WEEBs as the faulty module. This will ensure that there are never ungrounded modules in the array. W' L e y Document Number 104-0404000104-000 K gURfVDY' © 2012 BURNDY LLC. Page 5 of 6 SPLICE KIT ASSEMBLY FOR CROSSRAIL 36 f-- Everest Solar CrossRail 36. Copper Cable. Everest Solar Connector for CrossRail 36. WEEB-LUG-8.0 fastened on the CrossRail 36 Y using M8 T -Bolt and Flange Nut. Torque fasteners to 10ft-Ib/13.5N-m using Penetrox-A on threads. SPLICE KIT ASSEMBLY FOR CROSSRAIL 48 /--Everest Solar CrossRail 48. Copper Cable. Everest Solar Connector—' for CrossRail 48. WEEB-LUG-8.0 fastened on the CrossRail 48 using M8 T -Bolt (with an M10 T -Bolt Head) and Flange Nut. Torque fasteners to 10ft-Ib/13.5N-m using Penetrox-A on threads. Customer Service Department 7 Aviation Park Drive Londonderry, NH 03053 1-800-346-4175 1-603-647-5299 (International) W I Document Number 104-0404-000104-000 © 2012 BURNDY,LLC. BURNDY' Page 6 of 6 t ` �A Enphase® Microinve_ rters Enphase@M215 - - fel enphase i a E N E R G Y . The Enphase® Microinverter System improves energy harvest,` increases reliability, and dramatically simplifies design, installation, and management of solar power systems. y r. The Enphase System includes the microinverter, the Envoy® Communications Gateway," and ' Enlighten® Enphase's monitoring and analysis software. PRODUCTIVE , SMART - Maximum energy production ' - Quick and simple design, installation, , - Resilient to dust, debris and shading and management .,• r -'Performance monitoring " ' - 24/7 monitoring and analysis k RELIABLE SAFE - System availability greater than 99.8% : '` ' '. - Low -voltage DC , - No single point of system failure • M • . . `'` . t .. Reduced fire risk [ei enphase® r E N E.. R. G Y r i is, 4 C us Enphase® M215 Microinverter // DATA INPUT DATA (DC) M215-60-2LL-S22/S23 and M215-60-2LL-S22-NA/S23-NA (Ontario) Recommended input power (STC) Maximum input DC voltage 45V ` Peak power _tracking voltage 22-36V- 2-36V•Operating Operatingrange 16 - 36 V Min./Max. start voltage 22 V / 45.V Max. DC short circuit current 15A ' Max. input current 10.5 A OUTPUT DATA (AC) @208 VAC. 0240 VAC r Rated (continuous) output power 215-W,,_:,_ a 215 W Nominal output current 1.0 A (Arms at nominal duration) „ 0.9 A (Arms at nominal duration) Nominal voltage/range 208 /.183-229 V r 24042113-26 V Extended voltage/range .179-232 V 206-269 V t ' Nominal frequency/range 60.0 / 59.3-60.5 Hz, 60.0 / 59.3=60.5 Hz Extend ed.frequency range t 57-60.5 Hz 57-60.5 Hz Power factor >0.95 _ '>0.95' Maximum units per 20 A branch circuit x '25 (three phase) ` 17 (single phase) - Maximum output fault current . 1.05 Arms,'over 3 cycles; 1.04 Arms over 5 cycles ` EFFICIENCY , CEC weighted efficiency Peak inverter efficiency 96.3% Static MPPT efficiency (weighted, reference EN50530) 99.6% - Dynamic MPPT efficiency (fast irradiation changes, reference EN50530) 99.3% 'Night time power consumption 46 mW MECHANICAL DATA Ambient temperature range -40°C to + 65°C Operating temperature range (internal) -40°C to + 85°C Dimensions (WxHxD) , 17.3 cm x 16.4'cm x 2.5 cm (6.8" x 6.45".x 1.0") without mounting bracket Weight 1.6 kg (3.5 lbs) Natural convection = No fans Enclosure environmental rating Outdoor - NEMA 6 FEATURES - Compatibility . Pairs with most 60 -cell PV modules } Communication Power line ' Monitnrinn a FrPP. lifetimes mnnitorinn via Fnliahten software Compliance. •.UL1741/IEEE1547, FCC'Part 15 Class B CAN/CSA-C22.2 NO.•0-M91, 0.4-04, and -107.1-01 To learn more about Enphase Microinverter technology, visit enphase.com 0 2013 Enphase Energy. All rights reserved. All trademarks or brands in this document are registered by their respective owner. r l enphase® LJ E N E R G' Y ' F Engage Cable System and Accessories • y _ i ... n _ , '., r +.,I •, - tai:"' ri' d`' _ ,• r4'_ -Enphase@ Engage Cable + The Engage TM Cable is a continuous length of 12AWG cable with pre-installed connectors,for Enphase Microinverters, The cable is handled like standard outdoor -rated electrical wire, allowing it ' to be cut, spliced and extended as needed. The Engage Accessories complement the Engage *Cable and give it the ability to adapt to any installation. FAST FLEXIBLE SAFE - Quick installation _ - Simple design. ,F.^� - No high voltage DC ` - -Large branch capacity- No additional cables -Reduced fire risk ` T i E N E R G Y CC enphase° S A ,. - us ` Enphase® Engage Cable System # DATA CABLE TYPES / ORDERING OPTIONS Voltage Connector Spacing P.VModule Orientation Model Number`` #Connectors''.Weight",-,� 240 VAC, 4 conductors 1.025 meter (40") Portrait ET10-240-40 40 40 lbs 240 VAC; 4 conductors. • 1:7 meter,(67") = Landscape ET17-240-40^ 40 r , 45 lbs. 208 VAC, 5 conductors 1.025 meter (40") Portrait ET10-208-30 30 30 lbs 208 VAC,'5 conductors ,1.7 meter (67").. _ Landscape ET17-208-30 30 35 lbs 'additional lengths available through Enphase authorized distributors. "weights are approximate r , CABLE SPECIFICATIONS Description Rating Cable temperature rating 90°C (194°F) wet/dry Cable ins,.jlator rating THWN-2 7-7 UV exposure rating UL 746 C, F1 Conductor size 12AWG Compliance IEC 60529 IP67, CAN/CSA 22.2 No. 21, 182.3, UL 486A/13, 514C, 6703, and 9703 Cable rating TC -ER Cable Diameter 1.25 cm (0.49") Minimum bend radius' 12 cm (4.75•') A. ENGAGE ACCESSORIES " Branch Terminator Disconnect Tool, One terminator needed per branchPlan to use at least one per circuit + 1 installation o' ET -TERM -10 (sold in packs of 10) , - ET -DISC -05 (sold in packs of 5) Watertight Sealing Cap ' Cable Clip ® One needed to cover each unused Many needed to fasten cabling connector on the cabling - to the racking or to, secure looped ET -SEAL -10 (sold in packs of 10) cabling ET -CLIP -100 (sold in packs of 100) Engage Coupler Used for splicing two power cables within an array ' ET-SPLK-05 (sold in packs of 5) To learn more about Enphase Microinverter technology, re]-enphase0visit enphase.com E N E R G v © 2013 Enphase Energy. Al rights reserved. Al trademarks or brands in this document are registered by their respective owner. t