HomeMy WebLinkAboutB16-2762 041-030-0730 PROPOSED r..int CAQtMiAlt v1ENT SERVICES :OR �\NCE ESIDENCE 4 .LING UNIT. Poi; FIRE SPRINKLERS REQUIRED N0. OF STORIES 2 C CPG, CEC, CFC, Green auilding RY U C � a DRAWN e DJC DATE Cti U MR - 2017 r = ANDERSON IBARN SHEET OF 6 SHEETS Al _Az T 0 A) U _rn � Q3 U L Q � OE 0 � M Q) O M sill# .. _ N � A- �1 cn Q e e � a DRAWN e DJC DATE MR - 2017 JOB NAME ANDERSON IBARN SHEET OF 6 SHEETS e 2nd FLOOR PLAN a 121 0" 51 011 33'10" LCs, NO 50,0 261 0" 16' 0" 1 51011 W. P. 6x12 HDR. 'CONC. STOOP tH. B. 121 0° 2x6 WALL O- 6x12 HDR. A ® FORAGE. 3 \2x6 WALL GFI GFI p GFI 15' 0 3/4" HI, '= GFI O - I I I I 1 I I I I I I I CMD 350 C WIND - PLF 2x4 WALL w/ u 3'0" 1 3/8" 5/8" TYPE "X" d, 0 CONCRETE FLR. SOLID CORE pump RM, /� I t I I ANIMAL 5 I �J.l.. �' - I I s� o U GYP. BRD. � �• C D X _ O 1 - SIDE ap - CONCRETE FLR. CONC, t DIRT FLR. IQ <r GFI 3 o 3 1/2"x 111/8" EXPOSED V LAM BM, S' CEILING -4 S' CEILING 48" HI, GFI 1/25. FIELD NAILING - T -'- - r =r - r - r -' - r GFI STEEL PLAT�LT WALL I '- ° CONC. ON 2-2x tr WALL - Q, gi SIMP. H-1 SIMP, H-1 I I I 1 I I I 3 3 5/8" TYPE "X" GYP. BRD �. 31011 S' CEIL, SPACING 1/2" -0 36" 1/2" 6 24" O 11 I UNDER STAIRS t LANDING I I I I I 12'10" LG. No — HOLDOWNS , - \ 5 1/4"x11 1/8" V -LAM HDR,- w/ DR. w/ DBL. TRIMMERS 'I 3 6x12 HDR. p HD, 0 6'4" Q 0 a ANIMAL STALL 3 0 a CONC, t DIRT FLR, 48" HI O m 9' CEILING WALL O w � Ok 13' LG. A NO HOEDOWNS 2x4 WALL GFI O 1 +48 48" HI, GFI 1 WALL b� d O 6x6 POST w/ ECCQ 3 SDS2,5 3 � _ I 6x12 HDR, A A O HD,�64 - ' o o� 3.0.. 0 3 z amA. ROOF TRUSS 24" 0/C ANIMAL STALL - 0 CONC, t DIRT FLR. X' O b b S' CEILING 48" HI. WALL H. B. 10 2x4 WALL GFI +48" GFI 0 GFI FE 4 TACK 0 15'4" LCs. D NO CONCRETE FLR, 3 0�� O HOEDOWNS S' CEILING 4 O GFI 6, 3 SMEAR WALL SCHEDULE SHEAR WALL 6x12 HDR. A ® NOTES I i I I I I I I I I I I GFI p GFI HD.664 O SEISMIC - PLF I I I I 1 I I I I I I I CMD 350 C WIND - PLF o0 IQ 3'0" o CONCRETE FLR. I I s� o U E, F, C D X n or EXT. OBS 1,2 1 - SIDE ap I I H14ND AIL ,� � 8d (o" 8d 10 4" z ce 3 o .� (o) ANCHOR WASHERS t0 BE 3" SQ, x I/4" THICK 'I I 26 -1 l/16" RISERS I' UP � GFI 1/25. FIELD NAILING In 48" HI. STEEL PLAT�LT SILL PLATE I '- ° CONC. ON 2-2x tr WALL - Q, gi SIMP. H-1 SIMP, H-1 I I I 1 I I I 3 3 5/8"f 52" S' CEIL, SPACING 1/2" -0 36" 1/2" 6 24" O n Q3 21011 U r GFI15' 0 3/4" HI, 2x4 WALL w/ GFI 4 1 GFI L = 5/8" TYPE "X" GYP. BRD. 04 to 3'0" x 1 3/8" SOLID L 31 6�� 21 6�� CD H, B. 2x4 WALL GFI +48" an c� CORE 20 MIN. LABEL d GFI _ O E SELF CLOSING GFI +48" 48" HI, 0 cri GFI Q) WALL `= GFI 12'10" LG. No — HOLDOWNS , - \ 5 1/4"x11 1/8" V -LAM HDR,- w/ DR. w/ DBL. TRIMMERS 'I 3 6x12 HDR. p HD, 0 6'4" Q 0 a ANIMAL STALL 3 0 a CONC, t DIRT FLR, 48" HI O m 9' CEILING WALL O w � Ok 13' LG. A NO HOEDOWNS 2x4 WALL GFI O 1 +48 48" HI, GFI 1 WALL b� d O 6x6 POST w/ ECCQ 3 SDS2,5 3 � _ I 6x12 HDR, A A O HD,�64 - ' o o� 3.0.. 0 3 z amA. ROOF TRUSS 24" 0/C ANIMAL STALL - 0 CONC, t DIRT FLR. X' O b b S' CEILING 48" HI. WALL H. B. 10 2x4 WALL GFI +48" GFI 0 GFI FE 4 TACK 0 15'4" LCs. D NO CONCRETE FLR, 3 0�� O HOEDOWNS S' CEILING 4 O GFI 6, 3 SMEAR WALL SCHEDULE SHEAR WALL ® ® NOTES SLOPE FLOOR 1) OVER DOUGLAS FIR STUDS 6 16" 0/C . GFI ctl v SEISMIC - PLF 260 350 2) ALL PANEL EDGES BLOCKED w/ 2x FRAMING . U,O,N, 3) VERTICAL FRAMING FOR EDGE NAILING 9 ABUTTING WIND - PLF 335 485 o CONCRETE FLR. � f PANELS TO BE 44 POST or 2-2x STUDS w/ 2-ROUJS l(od SINKERS 6 12" 0/C FULL HEIGHT . 3/8" PLYWOOD C D X C D X or EXT. OBS 1,2 1 - SIDE 1 - SIDE 4) IF NAIL GUN IS USED , NAILS t0 HAVE A FULL HEAD , 5) TO BE INSTALLED 19 EACH END OF EACH TRUSS. EDGE NAILING 4 8d (o" 8d 10 4" W. P, _ .� (o) ANCHOR WASHERS t0 BE 3" SQ, x I/4" THICK 4 GFI 110" LG, FIELD NAILING Sd 12" Sd 6 12" STEEL PLAT�LT SILL PLATE 1 1/2" 11/2" THICKNESS ON 2-2x TRUSS TO PLATE 5 SIMP. H-1 SIMP, H-1 ANCHOR BOLT 6 5/8"f 52" 5/8" 6 36" SPACING 1/2" -0 36" 1/2" 6 24" 50,0" IN 1"x 20" EXPOSED VERSA LAM BM, CONCRETE FLR, 15' CEIL. w/ 5/8" TYPE "X" GYP. BRD. WALLS TO HAVE 1/2" GYP, BRD, 1"x 20" EXPOSED VERSA LAM BM. 100 AMP, El EC. SUB PANEL 3'0" 1 2x4 WALL mo M GFI �4 - N 6' 011 6x6 POST w/ ECCQ 1.1-6 SDS2.5 i 0 3'o" HUNTING 4 F15HING X CARPET 9' CEILING GFI 2x4 WALL GFI GFI x ROOF TRUSS g 24" 0/C N w 2x6 WALL n a SLOPE FLOOR 24 WALL GFI ctl v QQ z QUAD RM. 2x6 WALL 3 3'0" >3 > o o CONCRETE FLR. � f x 9 CEIL. T 0 , O Q1 -x 0 2x6 WALL to in a O GFI (ox(o POST w/ ECCQ 1.1-6 SDS2.5 '` - J' 1 X I GFI 2x4 WALL GFI TOOL RM, CONCRETE FLR, S' CEILING ELDOWNS 4" LG. W. P, GFI 220 DISC, C.U. a 2x6 WALL a O 24 WALL GFI ctl v GFIGFI L 12'x 14' OPENING 2x6 WALL 3 3'0" `a dtl5 1/4"x 111/8" VERSA LAM HDR, ;E n Q1 2 - 6'x 14' BARN DOORS $ B 6x12 HDR. Q) w O > W. P, _ .� 8' LG. GFI 110" LG, - co 8' LG. HDU4 HDU4 ao HDU4 ON 2-2x ON 2-2x ON 2-2x X 121 0" i, 26' 011 4 50,0" n (ox(o POST w/ ECCQ 1.1-6 SDS2.5 '` - J' 1 X I GFI 2x4 WALL GFI TOOL RM, CONCRETE FLR, S' CEILING ELDOWNS 4" LG. W. P, GFI 220 DISC, C.U. a a O ctl v L U Q) `a J m ;E n Q1 tk z< Q) w O > z Q _ .� - co ' _x r ao :7) X dl i, � 4 .n n Q3 GFI ,a an 3 WALL LG, NO HOLDOWNS 4 P PORCH GFI CONCRETE FLR,I IL i0 H7�VE 5/8" TYPE "X" GYP 3'0" a . RD. UNDER EXT, PLASTER X H. B. 51/4"x 111/8" VERSA LAM HDR, 8'x 8' OPENING 1st FLOOR PLAN 6Q* FT, cans. 1/4 ll _ 11 OII W, P. GFI CONC. STOOP 121 0" R-3 DUELLING = 18 1 SQ, FT. ACCE55ARY-1IU" — = 2613 5Q, FT, COVERED PORCH = 90 5Q, FT. TOTAL = 4Uo0 5Q, FT. PERMIT BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR CODE COMPLIANCE �1 a pF E S 5 54 w 0 017 D soy �e DRAWN - D J C DATE HAR 0 — 2017 JOB NAME ANDERSON BARN SHEET � � OF � SHEETS 0 O ctl v L U Q) `a m ;E � Q1 tk Q) O .� :7) 0 0 � !v__ � Q3 U 1 Q L co 13 04 to .. L z CD an d O E 1 cri Q) O M � CV Q e a soy �e DRAWN - D J C DATE HAR 0 — 2017 JOB NAME ANDERSON BARN SHEET � � OF � SHEETS 0 O to L U Q) m 0 � r Q) O .� :7) Q 04 L CD soy �e DRAWN - D J C DATE HAR 0 — 2017 JOB NAME ANDERSON BARN SHEET � � OF � SHEETS 0 0 2x4 OR 2x6 2x6 1611 0/C 16" 0/C w } 4" CONC, SLAB } 4" CONC, SLAB p 7 df 00 (o 411 BASE dJ N cv O #4 TOP 4 BOTTOM " 1 -STORY 12 0 0 12 2-6TORY 15 FOOTING FOOTING 2x4 A2x6 P. T. D. F. SILL OR 2x6 w/ 1/2" DIA, x 12" A. B. 16 0/C SNOT PIN 3" 50, x 1/4" 6'0" 0/C - U. 0. N. 4" CONC, SLAB WASHER 4" CONC, SLAB cz df O D 411 BASE 411 BASE CZ cep cv _ "4 TOP 4 BOTTOM " #4 TOP 4 BOTTOM 0 0 1211 1 -STORY o 0 121' I -STORY II C, 15 2-5TORY A -1-15 2-5TORY FOOTING ff2 FOOTING jT 2x6 tv 1611 0/C SHEAR WALL E.N. FLOOR TRUSS 2x CONT, SHAPED 2x4 SOLID BLKG. E -N" TO FIT w/ 2 - 16d 6 6" 0/C 16d Is 8" 0/C INTO TOP PLATE 4 BOTT, CORD OF FLOOR TRUSS 1/2" PLYWD. w/ TECH SHIELD RADIANT BEARIER t 13/4" x 1/2" CROWN STAPLES 6 6" / 12" 0/C UNBLOCKED PLYWOOD 5A, #I " SHOWER SHEAR PANEL T— 5 2x6 g 16" 0/C Ll j 1 , 1 1/2" PLYWD. w/ TECH SHIELD 12 - RADIANT BEARIER d 6� 2x6 16" 0/C 13/4" x 1/2" CROWN STAPLES 9 6" / 12" 0/C UNBLOCKED TRUSS 0 24" 0/C\1 2x6 LEDGER w/ 2 - 6DS25312 SCREWS TO THE CENTER OF EA, 2x6 STUD s 16" 0/C ANIMAL 5TA1_L 2x6 iv 16" 0/C 4" CONC. SLAB .DIRT FLOOR C 6x12 HDR. 2X8 CAP -2x6 f 16" 0/C �r- TRUSS a 24" 0/C MASTER 2x4 0 16" 0/C /3/4" T* PLYWOOD 11 l/8" FLOOR TRUSS a 16" 0/C " CONC. SLAB 2x6 6 1611 0/C TRUSS f 16" 0/C --_"� SHEAR 1)TL* PLYWOOD SHEAR PANEL 2x6 9 16" 0/C 5 -�� 12 �6 2x6 6 16" 0/C TRUSS A 24" 0/C 2x6 LEDGER w/ 2 - SD625312 6x12 HDR. SCREWS TO THE CENTER OF EA, 24 STUD o 16" 0/C TOOL RM. 2x6 g 16" 0/C SECTION 4 ..4.,roil O 1/2" IGNITION RESISTANT EAVE - TYP. 0 mer O _ an 50' 0" 12' 0" 26' 0" 1 Z -STORY 3 0 0 0 �pFESS/0 12 0 �ocHF���G�� 53P90 U e * A Tx 5 ri), CONC. STOOP o �' '�l o I I r— — — — — — — — —- - ----- — — — —— — — — — —— ---- --------1—r-- ---�----------------, � ' I 1 -STORY 2 1-5TORY I I 1 I 1 i 41 011 12 011 ' i i 2 -STORY 1 ' DIRT 2 I 1; FLOOR M I I 3 I I SI oll 161 oii .4 SI oil; 1 -STORY I ' 1 I I' — — — — — — — — — — — — — — — — — — — _ j_ I , I I , I I _ 2 I ;.n csJ I 1 3u I o 4" CONC, SLAB w/ =VID #3 6 24" 0/C E. W. 1-5TORY -1-- L---„_,40” SQ, x 1811 w/ ' 3611 SQ, x 18" w! S -4 EA, WAY 1--- -,-; 4 - #4 EA. WAY _ I 1 1 I ' 2 -STORY 1 I I I 1 3 ' L _ J o ' I DIRTi--------------_ FLOOR 2 -STORY 1 ' ' TYP. I I I I 3 �--- --� I 0 611 11611 81611 116ii o I 0 1 0 28" SQ, x 18" - MID 1 5 - #4 EA. WAY 12' 0" ' ' I 4 II CONC. 6LA5 I ' UJ/ #3 6 24" 0/G E, W, _ i DIRECTION OF SLOPE m I I GARAGE FLOOR SLOPED TO FACILITATE MOVEMENT OF LIQUID TO DRAIN OUT ' 1 ' 311 GARAGE DOOR AS PER I-6TORY311 , 2013 CRC R30S.1 I 4811 SQ, X 18" W/ ---L- --- ' 3 1 3 TYP. --- --1- 40" SQ x 18" w/ 8 - #4 EA, WAY 1 I 5 - #4 EA, WAY 1 , I 1 --- --T- 1 ( 1 1 o i 1 DIRT ' I I FLOOR 1 , I r — — — — — — — — — — — — — — — — , I � I i 2-5TORY ' 1- STORY i 2 1 1-5TORY 3 i 1 -STORY 1 I ' 3 I ' - I #3 - 4'011 LONG IN SLAB ' ' - - - ------- - - - - - J r _ _ _ _ _ - - - - - - - - - _ I i #3 - 4'0" LONG IN SLAB CENTER ON CORNER 1 i TYP. OF 2 i 2-STOI /`tl' 1i0 C 5LA5 W/ ' 1 -STORY i 1 RY 1 1 ; #3 6 24" 0/G E. W, ' ' I 3 2 -STORY 3 I , , 1 1 -STORY I, L _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ — _ - - _ _ _ — _ _ _ _ _ _ _ _ L_ _ _ _ _ _ _ _ _ _ _ _ _ _ J _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ J I sSTB20 I 55TB2055T520 I' oil 81 oil 31 oil 12'011 26'0" 1210ii 50' 011 OUNDATION NOTES 1, THIS FOUNDATION Is A "DOUBLE POUR" SYSTEM . 2. ALL EXTERIOR SLABS TO HAVE 2% MIN, SLOPE AWAY FROM STRUCTURE , AND "3 BARS 6 2411 0/C EACH WAY. 3, CONCRETE SUB -CONTRACTOR TO VERIFY ALL DIMENSIONS BETWEEN FOUNDATION PLAN 4 FLOOR PLAN PRIOR TO POURING CONCRETE. 4, SUB GRADE TO BE SATURATED w/ WATER TO A DEPTH OF 12" TO 1811 PRIOR TO POURING CONCRETE. 5, SLABS TO HAVE TOOLED JOINTS OR CRACK CONTROL STRIPS, 6, PROVIDE 6 MIL. VAPOR BARRIER UNDER SLAB w/ JOINTS LAPPED 6" MIN, 4 COVER w/ 2" MIN, OF SAND, 50'x 10' GONG. STOOP FOUNIDA 1/4"=110" TION PLAN. 61x 12' CONC. STOOP O co o IQ v - M 3 0 3 M rOUNTY DEVELOPMENT SERVICES REVIEWED FOR -y E 0,®mPLlNGE O o cz 3 0 3 M rOUNTY DEVELOPMENT SERVICES REVIEWED FOR -y E 0,®mPLlNGE a on O cn C�1 U s— U (P `v m 0 � (P76 c� Q co O d"I 0 U o L Q T 0 � U � 0 U- � � Bl v � c�s� 11 Q L co 9393 N Q) .. L � m a`' m 0 � ccl 0 0 M � Q- 61 Q e o a on DRAWN DJG � \ DATE HAR 9 - 2011 JOB NAME ,4N1)E:R50N 8,4RN SHEET 0 OF 4 SHEETS 0 O cn , � s— U m 0 � r O V Q co O d"I 0 L Q � T 0 U- Q) Bl � c�s� 11 Q N L DRAWN DJG � \ DATE HAR 9 - 2011 JOB NAME ,4N1)E:R50N 8,4RN SHEET 0 OF 4 SHEETS 0 0 I I ---------------- A ' „ I N� ------------- GENERAL NOTE5 1 3/4" x 1/2" CROWN STAPLE G 311 0/C ' L U ALL HEADERS TO BE 412 g 2x4 WALLS 4 64 20) BATH "1 EXHAUST FANS t0 BE "ENERGY 35) SMOKE ALARMS TO BE DIRECT WIRED TO BLDG, TRUSS G 24" OIC--'7MATERIAL D. F. 01 g 2x(o WALLS. - U, 0, N. STAR" COMPLIANT 4 TO BE DUCTED TO BE w/ BATTERY BACKUP t INTERCONNECTED TO I 5" DIA, FLEX DUCT -10' MAX, LENGTH AND ALL OTHER ALARMS , AS PER CRC R314 , 6 24" 0/C 2) CONTRACTOR TO FOLLOW ALL OF 2013 CALGreen TERMINATE OUTSIDE THE BUILDING t I PLATE LINE RESIDENTIAL MANDATORY MEASURES . A HUMIDITY CONTROL BE CONTROLLED N ROL 36) CARBON MONOXIDE ALARMS TO BE DIRECT 6 CHAPTER 4 , S BETWEEN A RELATIVE CAPABLE OF ADJUSTMENT WIRED TO BLDG, w/ BATTERY BACKUP 4 - 3) FIXTURES, LAMPS HOLDERS 4 OUTLETS TO BE HUMIDITY RANGE OF 50% TO 80%, INTERCONNECTED TO ALL OTHER C. M. ALARMS, AS PER CRC R315 SECURELY SUPPORTED, A FIXTURE WEIGHING AS PER 2013 CGBS 4.50(o. , 2x6 6 1611 0/C2x6 MORE THAN (6) POUNDS OR EXCEEDS 16" IN 21) MAX. FLOW RATES FOR PLUMBING FIXTURES : 31) GFCI REQD. FOR ALL 12 -VOLT RECEPTACLES. ANY DIMENSION SHALL NOT BE SUPPORTED BY THE SCREW SHELL OF A LAMP HOLDER. TOILETS =1.28 GPF , SHWR, HEADS : 2,0 GPM 38) PLUMBING FIXTURES WILL COMPLY w/ CA. qt OUTLET BOXES SHALL NOT BE USED AS THE ., LAUNDRY FAUCETS : 15 GPM t SENATE BILL 401, FOR THE INSTALLATION SOLE SUPPORT FOR CEILING (PADDLE) FANS. SINK FAUCETS : 1.8 GPM , OF WATER CONSERVING FIXTURES. a< 11- 22) ALL EXTERIOR OUTDOOR LIGHTS SHALL BE 39) THE BUILDER SHALL INSTALL A NORMAL I" INSIDE SOLAR 1' 4) BATH RM, TO BE SERVED BY A SEPARATE HIGH EFFICACY LUMINARIES or LOW EFFICACY DIAMETER, LISTED RACEWAY TO ACCOMIDATE A 20 AMP. BRANCH CIRCUIT. THIS CIRCUIT TO (INCANDESENT) LUMINARIES CONTROLLED BY A DEDICATED 208/240 VOLT BRANCH CIRCUIT. PANEL SERVE NO OTHER OUTLETS, MANUAL-ON/OFF SWITCH w/ A PHOTOCELL t THE RACEWAY SHALL ORIGINATE IN THE MAIN ARRAY; 5) BATH "2 EXHAUST FAN TO DOUBLE AS THE MOTION SENSOR, OR SUB -PANEL, t WILL TERMINATE INTO A LISTED "WHOLE - BLDG. EXHAUST FAN" t TO BE 15 din 23) DRYER VENT DUCT TO BE A MIN, 4" DIA, TO RIC BOX THE PURPOSED SITE OF ALL VEHICLE CHARGER. THIS AND ALL ADDITIONAL DDI ION -711 . Lu/ 6" DIA. SMOOTH DUCT - 145' MAX. LENGTH , THE OUTSIDE t EQUIPPED w/ A BACK DRAFT SPECS. OF THE CA. GREEN BLDG. STANDARDS CoY r A FAN TO BE RATED g I - SONE . FAN SWITCH BE LABELED , "WHOLE BUILDING VENTILATION DAMPER . SECTION 4.106.4 SHALL BE MET. FAN SHOULD OPERATE WHENEVER THE HOME 24) PROVIDE SEPARATE GROUND WIRE TO ALL 40) THE GROUND IMMEDIATELY ADLACENT TO THE Jo. 12 IS OCCUPIED". PANELS FROM MAIN SERVICE ENTRANCE PANEL. FOUNDATION SHALL BE SLOPED AWAY FROM pe ICACY AS PER 2013 CEC ART, 250-32, THE BLDG. is A SLOPE OF NOT LESS THAN 6" 6 ALL LIGHTING TO BE 100 HIGH LIGHTING IN LA OBE RM. ROOMS, 25) ALL EXTERIOR RECPTACLES MUST BE WATER WITHIN THE FIRST 10'0" (5% SLOPE). AS PER ,UTILITY -. t GARAGE TO BE CONTROLLED BY VACANCY PROOF/ GFCI PROTECTED. AS PER 2013 CEC 2013 CRC SECTION 8401.3 . SENSORS. ART. 210.52 (E) (U 4 210.8 , 41) LIGHT FIXTURES IN TUB or SHOWER ENCLOSURES F11be!ee!e 1) FIRE SPRINKLER PLANS ARE A DEFERRED 2(o) AFCI PROTECTION IS REQD, THROUGHOUT THE TO BE LABELED, "SUITABLE FOR DAMP LOCATION". AS PER 2013 CEC ART. t- iu V SUBMITTAL, TO BE SUMITTED PRIOR TO ROUGH DWELLING AS PER 2013 CEC ART. 210.12 (A) , (A) 4 (D), I FRAMING INSPECTION, ALL 120V SINGLE PHASE, 15 t 20AMP, BRANCH �41010 n.... 1 0- v I PLO I I I I I CIRCUITS SUPPLYING OUTLETS TO BE t42) ALL STAIR HANDRAILS 70 BE INSTALLED g 8) PROVIDE ON JOB SITE ADDRESS NUMBERS PROTECTED BY A LISTED ARC -FAULT 1i,,34"- 38" HI. ABOVE THE TREAD NOSING w/ 11/2" 11 1 1 I I I PLAINLY VISIBLE t LEGIBLE FROM THE PUBLIC INTERRUPTER , COMBINATION TYPE INSTALLED CLEAR BETWEEN HANDRAIL 4 WALL, 4 BE A "> STREET , NUMBERS TO CONTRAST w/ THEIR TO PROVIDE PROTECTION TO THE BRANCH I 1 1 1 TYPE I or 2 GRIP, AS PER 2013 CRC R311.18. 11 BACKGROUND 4 TO BE A MIN. OF 4 HIGH w/ A MIN, STROKE WIDTH Of I/2 CIRCUIT . INCLUDING LIGHTS , RECEPTACLES , 43) EXTERIOR WINDOWS TO BE DUAL PANE w/ ONE 4 SMOKE DETECTORS , PANE TO BE TEMPERED AS PER 2013 CRC I 9) ALL EXTERIOR OPENINGS , INTERSECTIONS 21) ALL 125V SINGLE PHASE, 15 4 20AMP. SECTION R321,8 rsQ) 4 ATTACHMENTS AS LISTED IN CRC R103.8 RECEPTACLES SHALL BE LISTED AS TAMPER (44) ALE"EXTERIOR DOORS TO BE 20 MIN. LABEL AS TO BE HAVE CORROSION - RESISTANT RESISTANT RECEPTICALES AS PER 2013 CEC I PER 2013 CRC SECTION R321.8.1 . FLASHING . ART. 406.12 . BRD, •, 45) PORCH CEILING 70 COMPLY w/ 2013 CRC 10) ALL EXHAUST FANS (INCLUDING RANGE HOOD) 28) PROVIDE A MIN. OF (l) 20AMP. RECEPTACLE SECTION 8321. z TO HAVE A BACK DRAFT DAMPER. IN LAUNDRY AREA , AS PER CEC 210.52 F , Dl 46) WOOD STOVE TO COMPLY w/ U. S. EPA PHASE 2 (o 12 11) PROVIDE R-23 INSULATION FOR EXTERIOR 29) PROVIDE A MIN. OF (2) 20AMP, SMALL EMISSION LIMITS t APPLICABLE LOCAL ORDINANCES. WALLS. AND R-49 IN THE ATTIC. APPLIANCE BRANCH CIRCUITS EVENLY 41) WATER HEATER DISCHARGE FROM A RELIEF VALVE --- 12) DRILLING 4 NOTCHING STUDS TO BE IN PROPORTIONED IN THE KITCHEN, PANTRY, DINING or SIMILAR AREAS TO SERVE ALL WALL- INTO THE WATER HEATER PAN IS PROHIBITED. -., ., 1 ACCORDANCE w/ CRC 8602.6. t FLOOR RECEPTACLES, SUCH CIRCUITS SHALL Fd --1 _. i J48) WATER NEATER PRESSURE RELIEF VALVE Td . 1 1 13) DOUBLE TOP PLATES t0 HAVE A MIN. LAP HAVE NO OTHER OUTLETS PER 2013 CEC TERMINATE TO THE EXTERIOR BETWEEN 6" t 24" ...._-, OF 24" NAIL w/ 8 - 16d ON EA, SIDE OF JOINT ART. 210. . ABOVE GRADE 4 POINTING DOWN AS PER 2013 CPC , U. 0. N, . LAP PLATES g INTERSECTIONS 4 30) BONA ALL METAL GAS t WATER PIPES SECTION 608.5,52(5) CORNERS. TO GROUND . ALL GROUND CLAMPS TO 9) THEELECTRIC WJIR GIN THE IIvESTOCK 6t4LL5 Te, ------------- j BE AN APPROVED TYPE 4 ACCESSIBLE . BE MC CABLE WIRING AS PER 2013 CEC ART. 54TA) 14J PROVIDE FIRE BLOCKING AS PER CRC 8302.11. t 541.5 (A - G). THE WIRING METHODS OF ARTICLE 502, 31) PROVIDE EROSION CONTROL 4 STORM �. PART 2 WILL BE ALLOWED FOR AREAS DESCRIBED IN 15) ANNULAR SPACES AROUND PIPES, CABLES , WATER POLLUTION PREVENTION MEASURES 541.1 64), CONDUITS , or OTHER OPENINGS IN PLATES g EXT. WALLS TO BE PROTECTED FROM RODENT DURING CONSTRUCTION . 50) THE ELECTRICAL GROUNDING SYSTEM TO COMPLY PASSAGE BY CLOSING OPENINGS AS PER 32) WATER HEATER TO HAVE : w/ CEC ART. 541.2 , EQUIPOTENTIAL PLANE. CGBS SECTION 4.406 . A) 2 - SEISMIC STRAPS. ONE STRAP g UPPER 51) SWITCHES, RELAYS, RECEPTACLES, CIRCUIT BREAKERS, 1(o) MATERIAL FOR EXTERIOR WILDFIRE EXPOSURE : 1/3 4 2nd STRAP TO BE g LOWER 1/3 NO CONTROLLERS t FUSES TO HAVE ENCLOSURES AS PER AS PER 2013 CRC SECT, R321, CLOSER THEN 4" OF CONTROLS. 5415 (C). 2013 CEC ART. 541.6, A) EXT, WINDOWS -TESTED TO MEET PERFORMANCE B) A CATEGORY 3 or 4 VENT, or a "B" VENT P52) LUMINAIRES'TO COh1F'LY w%Oi3`�laAR7. 541.8 REQUIREMENTS of SFM STANDARD 12 -1A - 2 . w/ STRAIGHT PIPE BETWEEN THE OUTSIDE (A) THRU (C). B) EXT. SIDING - HARDY BIRD. TERMINATION t THE SPACE WHERE THE CQ)`MINIMIZE THE ENTRANCE 'OF DUST,LUMINAIRES ,_- D) EXT, DOORS -TESTED TO MEET PERFORMANCE WATER HEATER IS INSTALLED AS PER CPC SECTION 509.6.2.E `SHALL BE INSTALLED TO MINIMIZE THE ENTRANCE wM F DUST, FOREIGN MATTER, MOISTURE 4 CORROSIVE REQUIREMENTS of SFM STANDARD 12 -1A - I . C) A CONDENSATE DRAIN THAT IS NO MORE MATERIAL: E) UNDER EAVE-1/2" IGNITION -RESISTANT MATERIAL THAN 2" HIGHER THAN THE BASE OF THE c5) EXP05ED'TO'PHYStCAL'DAMZ5.'I1MIRaIR56 SHTG, ON TOP OF TRUSS TAILS ONLY . INSTALLED WATER HEATER. AND ALLOWS EXPOSED TO PHYSICAL DAMAGE SHALL BE NATURAL DRAINING w/OUT PUMP ASSISTANCE, PROTECTED BY A SUITABLE GUARD. Il) AT THE TIME OF FINAL INSPECTION , AN p) A GAS SUPPLY LINE w/ A CAPACITY OF g t1'EXPOSED TO 'WATER: LUMINAIRES EXPOSED TO' OPERATION 4 MAINTENANCE MANUAL, ACCEPTABLE TO THE ENFORCING AGENCY , LEAST 200,000 BTU / HR, ` WATER FROM CONDENSATION, BUILDING CLEANSIf - (WATER SOLUTION SHALL BE LISTED AS SUITABLE TO BE PROVIDED t0 THE OWNER PER 33) ALL HOSE BIBBS (EXCEPT CLOTHES WASHER or FOR USE IN WET LOCATIONS, CG55 4,410 . CONNECTION) TO HAVE ANTI -SIPHON DEVICE . 53) KITCHEN LIGHTING TO COMPLY w/ 2013 CEC SECTION 18) ADHESIVES , SEALANTS , CAULKS , PAINT 34) LAUNDRY RM, OUTLETS TO BE SERVED BY g 150 (k) 3, STAINS , AEROSOL PAINTS , CARPET 4 LEAST lU 20AMP. BRANCH CIRCUIT, THIS 54) ALL RECESSED LIGHTS TO BE AT/IC RATED t COMPLY RESILIENT FLOORING TO COMPLY wl VOC CIRCUIT TO SERVE NO OTHER OUTLETS. w/ 2013 CEC SECTION 150 (k) 8. t OTHER TOXIC COMPOUNDS LIMITS PER CGBS 4.504 , 19) MOISTURE CONTENT OF BLDG, MATERIALS USED IN WALLS 4 FLOOR FRAMING IS NOT TO BE ENCLOSED IF THE FRAMING MEMBERS EXCEED 1990 MOISTURE CONTENT AS READ. 12 BY CGBS 4,505 . 612 �6 1/2" PLYWD. w/ TECH SHIELD RADIANT BEARIER 4 1212 13/4" x 1/2" CROWN - 3 ?BUSS 6 24" 0/C \ -�3 UNBLOLE66 b" CKED / 12" 0/C 1/2" PLYWD, w/ TECH SHIELD RADIANT BEARIER t 13/4" x 1/2" CROWN STAPLES g 6" / 12" 0/C UNBLOCKED 12 6 TRUSS g 24" 0/C 2x6 LEDGER w/ 2 - 50525312 SCREWS TO THE CENTER OF EA. 2x6 STUD g 16" 0/C ANIMAL STALL 2x(o g I6" 0/C C 4 CONC. SLA ,DIRT FLOOR 64 HDR. 51)RM. #3 mos 16 0/C ,3/4" T4G PLYWOOD 2x6 g 16" 0/C 6x12 HDR, 2x8 CAP -2x6 g I6" 0/C O BARN DOORS R1 METAL ROOFING GUTTER METAL ROOFING GUTTER 1/811 -- 11 0" LEFT 1/8" -- V 0" Sd's (Oil 0/C I I ---------------- A ' „ I N� ------------- 1/2" IGNITION 1 3/4" x 1/2" CROWN STAPLE G 311 0/C 5''6:12 L RE515TANT 11 r■mm�■■ommm TRUSS G 24" OIC--'7MATERIAL m■■■mm�nnon 3LLI 2x8 FACIA I SHEAR WALL---'vZL11O 6 24" 0/C � 0 I PLATE LINE SIMP, N1 CLIP 6 UI TYP, 9 ALL .A - E• N. TRUSSES 4 ' ' 1 ' 2x6 6 1611 0/C2x6 6 1611 0/C SHEAR WALL 1 1 , qt O :7' Q) # a< 11- 1' 50LAR SOLAR 1' o ' PANEL ; PANEL VI ARRAY; ; ARRAY ; g Q -711 CoY r A w I to N Jo. 12 METAL = _CHIMNEY ' pe s~ I 1 I I I F11be!ee!e I t- iu V 1 1� 1P, I i 11 11 11 I OL Q t 1 0- v I PLO I I I I I v I I 1 3:12 6:12 �_ �_ I /1 X6:12 x'3:12 1--� 1 1 -► I 1 11 1 1 I I I 11 , 1 21 011 I 1 2' 0 I 1 1 1 1 I 1 1 1 I 11 METAL ROOFING - OOFING6:12 OE3 O I c cA rsQ) O erl BRD, •, I�� z Q - �I�IIIIII Dl (o 12 6 : 12 ��III�III 6 --- ; -� 15 I I I 3 1 0 4 1 1 I�I�III 4 11 ' ------- '-------- BARN DOORS R1 METAL ROOFING GUTTER METAL ROOFING GUTTER 1/811 -- 11 0" LEFT 1/8" -- V 0" Sd's (Oil 0/C I I ---------------- A ' „ I N� ------------- 1/2" IGNITION 1 3/4" x 1/2" CROWN STAPLE G 311 0/C 5''6:12 L RE515TANT 11 6 TRUSS G 24" OIC--'7MATERIAL ALL EAVE5 3LLI 2x8 FACIA I SHEAR WALL---'vZL11O 6 24" 0/C � 0 I PLATE LINE SIMP, N1 CLIP 6 UI TYP, 9 ALL .A - E• N. TRUSSES 4 ' ' 1 ' 2x6 6 1611 0/C2x6 6 1611 0/C SHEAR WALL 1 1 L :ING =R L -ING ER 64 HDR. --A WALL 5pR M. *2 CV- SHEAR IDTL SHEAR IDTLF(0 o x4,0 16"0/C SIMILAR 2x6 g I6" 0/C --_ 3 TYPICAL ATTIC VENT CALC5. 50% OF REQD, VENTING TO BE IN THE UPPER PORTION OF ATTIC . \111/a" FLOOR TRUSS 16" o/c (UPPER PORTION 15 310" MIN, ABOVE THE EAVE VENT5J 12 2nd FLOOR ATTIC 2x6 g 16" o/c 10 1/2" IGNITION ATTIC -- 1560 SQ, FT, 0 300 -- 5.20 SQ. FT, -02-1 -- 1.43 SQ, FT, TRESISTANT TOTAL 2nd FLOOR REQUIRED VENTING RUSS 0 24�� 0/C . EAVE -TYP. 2 GABLE VENTS PROVIDED -- 3.10 SQ, FT. BARN 5 I/4"x II 1/811 2x6 LEDGER w/ 2 - _ PROVIDE 14 - 3.5"x 14" EAVE VENTS - 4.16 SQ, FT, V -LAM HDR. SD525312 5 I/4"x 111/8" „��* SPACED EQUALLY ALONG 2nd FLOOR EAYE, SCREWS TO THE CENTER V -LAM HDR. OF EA, 2x6 STUD g 16 0/C let FLOOR ATTIC QUAD RM. � ATTIC = 1440 SQ, FT, 0 300 -- 4.80 SQ. FT, o "1 = 6.86 SQ. FT. o TOTAL 1st FLOOR REQUIRED VENTING . PROVIDE 8 - 3.5"x 20" DORMER VENTS = 3.92 SQ, FT, PROVIDE 14 - 1511x 14" EAVE VENTS -- 4.16 SQ, FT, SPACED EQUALLY AROUND 1st FLOOR EAYE, 4 CONC, SLAB - ATTIC VENT NOTES 6ECTION S ..4., r oil 1. EAVE VENTS TO BE 11VALCAN11 or TESTED EQUIVALENT, 2, PROVIDE 1" AIR SPACE BETWEEN INSULATION 4 ROOF SHTG, AS PER CRC 1203.2 . 3. GABLE VENTS TO BE FULLY COVERED w/ METAL WIRE MESH w/ MIN. OF 111611 4 NOT TO EXCEED 1/811 OPENINGS. 14"x 16" 1/8"=110" IWO M v� • C� 4 4 PROVIDE 13 - 16d SINKERS FRoNT g EA, SIDE OF TOP PLATE 1/8" = 11 0" SPLICE FOR ENTIRE 2nd FLR. 4 4 =1 v v 0 I I ---------------- A ' „ I ,r- Y " ------------- " 11 5''6:12 L i z 11 6 I 3LLI -'6, 12 I , � 0 I II 6 UI l V 1 1 4 ' ' 1 ' I I 1 1 , qt O :7' Q) # a< 11- 1' 50LAR SOLAR 1' o ' PANEL ; PANEL VI ARRAY; ; ARRAY ; g Q -711 CoY r A w I to N Jo. 12 METAL = _CHIMNEY ' pe s~ I 1 I I I 1 I 6:12 I t- iu V 1 1� 1P, I i 11 11 11 I OL Q t 1 0- v I PLO I I I I I v I I 1 3:12 6:12 �_ �_ I /1 X6:12 x'3:12 1--� 1 1 -► I 1 11 1 1 I I I 11 , 1 21 011 I 1 2' 0 I 1 1 1 1 I 1 1 1 I 11 METAL ROOFING - OOFING6:12 OE3 O I c cA rsQ) O erl BRD, •, CD z Q - Dl (o 12 6 : 12 Q 6 --- ; -� 15 I I I 3 1 0 4 1 1 4 11 ' ------- '-------- J� ------------- j v v 0 of 1 1 1ROOF PL 4 4 .RooF NoTE6 4 1/811 = it O11 1, ROOF PLYWOOD TO BE 1/211 CDX w/ TECH SHIELD 5, TECH SHIELD RADIANT BARRIER or EQULL TO BE RADIANT BARRIER or EQ. 4 13/4" x 1/2" CROWN INSTALLED ON ALL VERTICAL SURFACES IN THE STAPLES 6 611 / 12" 0/C . STAPLE CROWNS TO BE ATTICS, IN LINE w/ FRAMING MEMBERS . 2. PROVIDE H1 CLIP 6 EACH END OF ALL TRUSSES. PE ,?A1 P" !TTE COUNTY DEVELOPMENT SERVICES 3, FASTENERS FOR ROOF COVERING TO BE _REVIEWED FOR CORROSION RESISTANT • CRC 1501. ,ODE COMPLIANCE 4, ROOF GUTTERS TO HAVE THE MEANS TO PREVENT DATE- " � BY 01V-' THE ACCUMULATION OF LEAVES 4 DEBRIS AS PER 2013 CRC SECTION R321.5.4 . . L U I ; Him 6 C �C+ pl' , � 0 ` OF: c, �G Z Ov 1 qt O :7' Q) # a< 11- � o � VI • g Q -711 CoY r A N ' pe s~ L � Q QQ3 O (p OE3 O I c cA rsQ) O erl BRD, •, CD z Q - Dl Q 0 0 0 I I 0 of 1 1 1ROOF PL 4 4 .RooF NoTE6 4 1/811 = it O11 1, ROOF PLYWOOD TO BE 1/211 CDX w/ TECH SHIELD 5, TECH SHIELD RADIANT BARRIER or EQULL TO BE RADIANT BARRIER or EQ. 4 13/4" x 1/2" CROWN INSTALLED ON ALL VERTICAL SURFACES IN THE STAPLES 6 611 / 12" 0/C . STAPLE CROWNS TO BE ATTICS, IN LINE w/ FRAMING MEMBERS . 2. PROVIDE H1 CLIP 6 EACH END OF ALL TRUSSES. PE ,?A1 P" !TTE COUNTY DEVELOPMENT SERVICES 3, FASTENERS FOR ROOF COVERING TO BE _REVIEWED FOR CORROSION RESISTANT • CRC 1501. ,ODE COMPLIANCE 4, ROOF GUTTERS TO HAVE THE MEANS TO PREVENT DATE- " � BY 01V-' THE ACCUMULATION OF LEAVES 4 DEBRIS AS PER 2013 CRC SECTION R321.5.4 . DRAU)N DJC DATE MAR Q - 2017 JOB NAME ,4NE)MRSON 5 4RN SHEET 0 0 OF 4 SHEETS OCIO, L U Q) 7 � 0 � Ov 1 L O :7' Q) # 11- � o � VI • Q -711 N 4* s~ DRAU)N DJC DATE MAR Q - 2017 JOB NAME ,4NE)MRSON 5 4RN SHEET 0 0 OF 4 SHEETS