Loading...
HomeMy WebLinkAboutB16-2888 047-770-005Lit O N O r (P w 0 W O r N C �- ��� Z om W O � n A 5 2 q SOFT TRELLIS for: I w NN>-INA-nrnrnN"n -i-iNrrnOOXXor-{ O � ccrn�-O_iOzrnrn00 _ 1'-0' 14' 402OL5 1- n (N zm13z (1�130000000(A 5'-0• Oz n p--„,,-- i(f1LWWWWwwwLo -- A-dA �rnO > 300�00o0or c zO>D>D>DDD �6c0zZrrrrrrrr S —-< r 11 �1 ti =,”9 1i 1i =n Z Z -j -� mWID N-(OA�AAAAAA� ° ° r A pzzzZzzzz p ° A/�r�nzc?jrrnQ% rn-03ACA� °a ° N •• < C �OZQ%0 >r°n� rCp�OAzzzOi A m41cv`�� P OL mdd�rQrro n zrn�orno0°� rn �N �ri r°nnrn°^tea ° ° z (� ' x A z a m a ° P N V D n ° o a .ID• P Q in °. O rnnc AcA> > AmW-0 -1 O rn rnt�3r03c0; rn z-+Nm°>-n"'r - to m T0Amz I-izOm0-10 I- rx-iz(Azxdj O > clP —rn' 10 rnrD(�zcAp rn (31 nAN>D D ( A� A rn 3y z� r 7III 7 �> 70 Iffi rn O D �N A; rn (` c j 0 � C3j WN f YD ONNrn� °°>>-o-�p \.� �p C7C1N000-� A13U m � +✓ � N Cq ID 3 rnZ"' Sou r7C N c -i r •' yz> t, + to r- rn 130 A I z zr0 AO ?A rn m ° rn O z 2'-1 O" 2'-6` 2'-8' 402OL5 402OL5 R 205OR5 o ° p 4'-1 O' P a ° 50'-1 O 5/4`® 11 CONO. UNIT T -2- 5.-q. L 5'-5` 505OL5 5040R5 N�rn m Uom 70rnN > 10 m mon Arn 3> .p /0 z> nzm V• V 52'-0* 10'-2' 8'-8' 1 V-0" 1 "1'-O' 5'-5' 4'-1 1 ` 2'-4' 14'-1 O' N P w N --� �►� �y-i> -i-n> 7arnx° NN r Ay Agrnr O�-( n-6AO rnrn N 4020L5 3050511 30505H 13 -4 4rn A rn O> X rn °° 0 A° Z -� N 01 zvrnm nON AN�� N� ZA °NAA �� C rn rn N 2rn3 nr (� rn n rnrn*d rn0D -i0Ci Az c n� zOA7 ANn Zrnrn Drn �r �m> ONN �xA °_U r D X Z N rrn z3 ri rnzJU rn Z a-�= Ozq� 01 -� MVI Z-1 O z Nix 0p1:2 p N -{ ° rn0 c D Arnrn Zz rn9 rZ rnAr d3z O>N zy N A > ul 3c nZ O z nrnrn rnUD > 13W N rn lu > Lp rIII od Q% - �r rrnn�rn or A porn rjj Acj A-1� rn OmA D -n > -n N r a► Ri � z 6 8 X °D D a V D L a V D V V p d a v P V p V D V � V d _ rnp V ° a V V D ° m O D Dp V _ a ° V ° rn V X X X N rn rn °° r ° D a d n p ## V ° P p V # _ O� Dul r 1 a n C• I D V ° V 00 c 9'-O' 12'-0' D 5'-0' p m V V D 0 - ° AtEEIp V a ° rn 3 X _ a ° V ° V i ° I Oz ° Q P V — — Z rn V� D N d ° ° it Ir I rnV D 5068 ° rn > rn ° n Til 11M A rnrn > Z z rrnn X 44 N z �rrnn w', V .16080 p V D V 16050 a V D a D V D p V 2'-8' W-2' a a 12'-O" D a V 21'-O" ° ° till V a D D V-1 O' 110'-10' v V ° 44'-0` ° D a 51'-1 1/4' a a p V D Q V D C ® w O rt � w W O � N A 5 2 q SOFT TRELLIS for: I w NN>-INA-nrnrnN"n -i-iNrrnOOXXor-{ O � ccrn�-O_iOzrnrn00 _ - q N> N A_Arn� z �s N> -Oi-OitNi►rnOrngCf rz�' O rn AAAz>> —nr,< - m N rr3 NzO�TO V A v, Z rnoz p �' r -0 > N r ,� m r • 1 > A n a) r EXTERIOR PICTORIAL PATRICK FLAHERTY 4 LORI HEAD O n r z r n> y � � z„< z rN >O iNn{ :c In r N Z Wz :QO{N 0 o P o p o rn V sax 3 9 4 2 5PY(5LA55 ROAD CHICO CALIFORNIA q 5 q7 3 ° OInO 1a nAtl mss✓. a p D tvm� ° :aDD n i0 r� DAZ-T r -i 2'-1 O" 2'-6` 2'-8' 402OL5 402OL5 R 205OR5 o ° p 4'-1 O' P a ° 50'-1 O 5/4`® 11 CONO. UNIT T -2- 5.-q. L 5'-5` 505OL5 5040R5 N�rn m Uom 70rnN > 10 m mon Arn 3> .p /0 z> nzm V• V 52'-0* 10'-2' 8'-8' 1 V-0" 1 "1'-O' 5'-5' 4'-1 1 ` 2'-4' 14'-1 O' N P w N --� �►� �y-i> -i-n> 7arnx° NN r Ay Agrnr O�-( n-6AO rnrn N 4020L5 3050511 30505H 13 -4 4rn A rn O> X rn °° 0 A° Z -� N 01 zvrnm nON AN�� N� ZA °NAA �� C rn rn N 2rn3 nr (� rn n rnrn*d rn0D -i0Ci Az c n� zOA7 ANn Zrnrn Drn �r �m> ONN �xA °_U r D X Z N rrn z3 ri rnzJU rn Z a-�= Ozq� 01 -� MVI Z-1 O z Nix 0p1:2 p N -{ ° rn0 c D Arnrn Zz rn9 rZ rnAr d3z O>N zy N A > ul 3c nZ O z nrnrn rnUD > 13W N rn lu > Lp rIII od Q% - �r rrnn�rn or A porn rjj Acj A-1� rn OmA D -n > -n N r a► Ri � z 6 8 X °D D a V D L a V D V V p d a v P V p V D V � V d _ rnp V ° a V V D ° m O D Dp V _ a ° V ° rn V X X X N rn rn °° r ° D a d n p ## V ° P p V # _ O� Dul r 1 a n C• I D V ° V 00 c 9'-O' 12'-0' D 5'-0' p m V V D 0 - ° AtEEIp V a ° rn 3 X _ a ° V ° V i ° I Oz ° Q P V — — Z rn V� D N d ° ° it Ir I rnV D 5068 ° rn > rn ° n Til 11M A rnrn > Z z rrnn X 44 N z �rrnn w', V .16080 p V D V 16050 a V D a D V D p V 2'-8' W-2' a a 12'-O" D a V 21'-O" ° ° till V a D D V-1 O' 110'-10' v V ° 44'-0` ° D a 51'-1 1/4' a a p V D Q V D C ® w w � w W O � N A 5 2 q SOFT TRELLIS for: Ott w o O � 0 - q N> N N ttt N> x N W ` A v, I O p �' r N rn N r ,� m r • w n a) r EXTERIOR PICTORIAL PATRICK FLAHERTY 4 LORI HEAD O n r z r n> y � � z„< z o In 00 z 0 o N •• o p o rn rn 3 9 4 2 5PY(5LA55 ROAD CHICO CALIFORNIA q 5 q7 3 Z> U] ;a rn r�� rn -p A rn rn o rn N mss✓. 2'-1 O" 2'-6` 2'-8' 402OL5 402OL5 R 205OR5 o ° p 4'-1 O' P a ° 50'-1 O 5/4`® 11 CONO. UNIT T -2- 5.-q. L 5'-5` 505OL5 5040R5 N�rn m Uom 70rnN > 10 m mon Arn 3> .p /0 z> nzm V• V 52'-0* 10'-2' 8'-8' 1 V-0" 1 "1'-O' 5'-5' 4'-1 1 ` 2'-4' 14'-1 O' N P w N --� �►� �y-i> -i-n> 7arnx° NN r Ay Agrnr O�-( n-6AO rnrn N 4020L5 3050511 30505H 13 -4 4rn A rn O> X rn °° 0 A° Z -� N 01 zvrnm nON AN�� N� ZA °NAA �� C rn rn N 2rn3 nr (� rn n rnrn*d rn0D -i0Ci Az c n� zOA7 ANn Zrnrn Drn �r �m> ONN �xA °_U r D X Z N rrn z3 ri rnzJU rn Z a-�= Ozq� 01 -� MVI Z-1 O z Nix 0p1:2 p N -{ ° rn0 c D Arnrn Zz rn9 rZ rnAr d3z O>N zy N A > ul 3c nZ O z nrnrn rnUD > 13W N rn lu > Lp rIII od Q% - �r rrnn�rn or A porn rjj Acj A-1� rn OmA D -n > -n N r a► Ri � z 6 8 X °D D a V D L a V D V V p d a v P V p V D V � V d _ rnp V ° a V V D ° m O D Dp V _ a ° V ° rn V X X X N rn rn °° r ° D a d n p ## V ° P p V # _ O� Dul r 1 a n C• I D V ° V 00 c 9'-O' 12'-0' D 5'-0' p m V V D 0 - ° AtEEIp V a ° rn 3 X _ a ° V ° V i ° I Oz ° Q P V — — Z rn V� D N d ° ° it Ir I rnV D 5068 ° rn > rn ° n Til 11M A rnrn > Z z rrnn X 44 N z �rrnn w', V .16080 p V D V 16050 a V D a D V D p V 2'-8' W-2' a a 12'-O" D a V 21'-O" ° ° till V a D D V-1 O' 110'-10' v V ° 44'-0` ° D a 51'-1 1/4' a a p V D Q V D C ® w O w W 0 T- {SGPEOFWORK N A 5 2 q SOFT TRELLIS for: x w o Il�vl 0 - q N> 0 N ttt N> O (P rnM A Z ` 2'-1 O" 2'-6` 2'-8' 402OL5 402OL5 R 205OR5 o ° p 4'-1 O' P a ° 50'-1 O 5/4`® 11 CONO. UNIT T -2- 5.-q. L 5'-5` 505OL5 5040R5 N�rn m Uom 70rnN > 10 m mon Arn 3> .p /0 z> nzm V• V 52'-0* 10'-2' 8'-8' 1 V-0" 1 "1'-O' 5'-5' 4'-1 1 ` 2'-4' 14'-1 O' N P w N --� �►� �y-i> -i-n> 7arnx° NN r Ay Agrnr O�-( n-6AO rnrn N 4020L5 3050511 30505H 13 -4 4rn A rn O> X rn °° 0 A° Z -� N 01 zvrnm nON AN�� N� ZA °NAA �� C rn rn N 2rn3 nr (� rn n rnrn*d rn0D -i0Ci Az c n� zOA7 ANn Zrnrn Drn �r �m> ONN �xA °_U r D X Z N rrn z3 ri rnzJU rn Z a-�= Ozq� 01 -� MVI Z-1 O z Nix 0p1:2 p N -{ ° rn0 c D Arnrn Zz rn9 rZ rnAr d3z O>N zy N A > ul 3c nZ O z nrnrn rnUD > 13W N rn lu > Lp rIII od Q% - �r rrnn�rn or A porn rjj Acj A-1� rn OmA D -n > -n N r a► Ri � z 6 8 X °D D a V D L a V D V V p d a v P V p V D V � V d _ rnp V ° a V V D ° m O D Dp V _ a ° V ° rn V X X X N rn rn °° r ° D a d n p ## V ° P p V # _ O� Dul r 1 a n C• I D V ° V 00 c 9'-O' 12'-0' D 5'-0' p m V V D 0 - ° AtEEIp V a ° rn 3 X _ a ° V ° V i ° I Oz ° Q P V — — Z rn V� D N d ° ° it Ir I rnV D 5068 ° rn > rn ° n Til 11M A rnrn > Z z rrnn X 44 N z �rrnn w', V .16080 p V D V 16050 a V D a D V D p V 2'-8' W-2' a a 12'-O" D a V 21'-O" ° ° till V a D D V-1 O' 110'-10' v V ° 44'-0` ° D a 51'-1 1/4' a a p V D Q V D C ® w W -• T- {SGPEOFWORK FLOOR PLAN A 5 2 q SOFT TRELLIS for: > x rn o Il�vl 0 - q N> N N N> EXTERIOR ELEVATION =�Op c z r rnM A Z ` A v, m1 p �' r N rn N r ,� m r N N pAQ ,� a n d .fl T n a) r EXTERIOR PICTORIAL PATRICK FLAHERTY 4 LORI HEAD A z ►n Z� �_-az N N fci Z — � rn v, o n r z r n> y � � z„< z o 00 z 0 o N •• o p o rn rn 3 9 4 2 5PY(5LA55 ROAD CHICO CALIFORNIA q 5 q7 3 Z> U] ;a rn r�� rn -p A rn rn o rn N mss✓. DAZ-T r -i ASSESSORS PARCEL # 041 - -170 - 005 c-nto A r° A w ° N N ZrCl�Arnr � � ° < r a N Q a TA�ytom 1 Q 0 tAo a Oa n z <Amm w > .A cr iP 1 Z e■ x r o �n { mOtlrAO cztl03A 0 13 Cy cpai�30� z�aimmDi 2 Z JJ 1 Z DAF 9 ='zAz« ADm= +i N rn �-1r - :i i O { ��omo ADNNmIfi V1 I map ZNNZ\I �AM> > Q U m z a cul 2"x4" DF# 1 AT 1 b" C/C✓ 6"xS" DF# 1 AT 50" G/G 14'1 O' -b" BOTTOM OF BEAM/ b"x 1 b" DF# 1 BRACE PER 2/5D 1 CE1_RE5IDENGEv� (E1_ RESIDENCE 2'-b" 50UARE x 12" THICK FOOTING (E) W CONCRETE SLAB 77 FOUNDATION DETAILS: SEE STRUCTURAL PAGE5 FOR DETAILS 25c#T10N Aid SCALE: 1/4" 1'-0' SEC. 33, T. 23N. R.1 E. M.D.B. &M. LOT A 47-11-1 N88°45'30'E , 28776 916.50 12' I J n oN 1"=20G' I 0 71 50 .78Ac Pr w �m C(q� 50 .96AC S1 rr, 45 f3s 10 49 49 5 LOT E ire ❑ REM. PTN q° -45 0D T 25?71 .56Ac Vis.°� j 9,47Ac % m 6 48 I ��m r>i9z � 45Ac 48 m6 aq � g2,13 65A0 64.87 Ip°p 47 Oggy o.64Ac N89°49'30°E ,t3os 644c F Zoa?Zy3 r 6o q 140.23 ,.0 N ✓ ,58AC p'57AC ST 13?>, 44 35AC �6 q�a� 43 43 36 rs° ' 46Ac 53Ac 30 30 31 31 AUC S o w 28 29 29 39 39 Iq CT 42 42 y�ae m6, O 36 c 29a.6t i 28 59Ac 56Ac Op 36 y2 q RdPD 27 27 G ( 40 40 b°' s is 72Ac 2o9.3a 89AC PRv�P 22 22 .38Ac 41 41 �86g 2°� ��g 35 35g 23 23 ,57AC .46P.c tiya' 26 26 N EK 1,i 24 24 ,52Ac ��sy3 le.>9 634 RE 0 25 25 .65Ac 52Ac ti 9211 p r9�se 34 1.11AC P m 38 oN sp5.00 38 j 533h P U bZ� ppb?g,3Ag'I O ,5BAC 116, 33 M1 LOT C 21/ Np � 3737 Vi S6 sa.s� m Nw s$64 Ac 61Ac 32 ' s 20 � 8 20 2 53A56Ac 3 55Ac AlSAc 19 ❑ N 17 17 18 18 19 10 10 s, / -S O 41Ac g9 71 16 78Ac BP1212. 196.54 f ti� 15 3 .49Ac s9 0° s SOAc i / 1100Ac 14 1348Ac�7 aq / REM. PTN. �166Ac �0 64 '8 .48Ac� 6 l5c J6 , 71 90.85 2' 199_.68 �3y o ..~ 5 hoti 5 � 184.52 10 97 �s .4 Ac `'2 JJ J� 4 50Ac OC> P 4 SIERRA MOON MOON SUB., PH, 1, 172 M.^u.P, 29/35, 09-17-07, LOTS 1/50 & E Y a° Q� N a 632c �3 2y S >> Butte County Assessor's Map Vyye LOT 6 Book 47, Poge 77 r -11.40Ac _ ;Oe000l zpo'� PROPANE TANK: EXISTING X 0 i .-SLOPE"r / PROP05ED TRELLIS:: \ (Ej SEPTIC: A5 PER BUTTE COUNT EALTH DEPARTMENT RE0UIREMFNT5. \ WATER SERVer, CONNECTED TO�k4ATER SERVICE. aALGREF'N MOTES: DURING CONSTRUCTION, ONE OR MORE OF THE FOLLOWING MEASURES SHALL BE IMPLEMENTED TO PREVENT FLOODING OF THE ADJACENT PROPERTY, PREVENT EROSION d RETAIN SOIL RUNOFF ON THE SITE: A.) RETENTION BASINS OF SUFFICIENT 51ZE SHALL BE UTILIZED TO RETAIN STORM WATER ON THE SITE. B.) WHERE STORM WATER 15 CONVEYED TO A PUBLIC DRAINAGE SYSTEM, COLLECTION POINT, GUTTER OR SIMILAR DISPOSAL METHOD, WATER SHALL BE FILTERED BY USE OF A BARRIER SYSTEM, WATTLE OR OTHER METHOD APPROVED BY THE ENFORCING A61i C.) COMPLIANCE WITH A LAWFULLY ENACTED STORM WATER MANAGEMENT ORDINANCE. METHODS TO MANAGE 5URFAGE WATER INCLUDE: SWALES, WATER COLLECTION AND V15POSAL SYSTEMS, FRENCH DRAIN5, WATER RETENTION GARDENS d OTHER WATER MEASURES WHICH KEEP SURFACE WATER AWAY FROM BUILVIN65 AND AID IN GROUNDWATER RECHARGE. EROSION_ CONTROL PLAN: 1.) NO 501L DISTURBANCE SHALL OCCUR PRIOR TO OBTAINING A BUILDING PERMIT OR GRADING PERMIT. 2.) THE CONTRACTOR SHALL BE RE5PON51BLE FOR EROSION CONTROL. 3.) ER05ION CONTROL MEASURES SHALL BE IN PLACE BETWEEN OCT. 15TH d APR. 1 5TH, OR WHEN RAIN 15 FORCA5TED. 4.) SOILS TRACKED OFF 51TE INTO STREETS SHALL BE GLEANED UP AT THE END OF EACH WORK DAY. 5.) INACTIVE SOIL STOCKPILES SHALL BE COVERED. ACTIVE STOCKPILES SHALL BE COVERED PRIOR TO A FORGASTED RAIN EVENT. b.) THE EROSION CONTROL PLAN SHALL BE RE-EVALUATED 4 ADJUSTED ACCORDINGLY A5 THE 51TE CHANGES 4 AFTER RAIN EVENTS. S� 7.) EROSION CONTROL MEA5URE5 SHALL BE MAINTAINED. 8.) PLACE SIGN AT WASHOUT: WASHING OF CONCRETE EQUIP. 6 TOOLS AT ANY OTHER LOCATION THAN A DE516NATED CONCRETE WASHOUT 15 A VIOLATION OF LAW 4 SUBJECT TO FINE. PROPERTY OWNER: • PATRICK FLAHERTY 5 ci 5PYGLA55 ROAD, CHICO, GA 95 9 13 PHONE (408) 506-1-105 CONTRACTOR: • ERIK JONES GONG. DRIVEY+IAY' 2685 VISTAMONT WAY, CHICO, GA 959-15 PHONE(550)828-9590 51TE ADDRESS: NONE ASSIGNED :.< A CONSTRUCTION IO / 1 5/20 5 APPROX END: 2/1 5129 5 / / O' BUILDING SETBACK LINE BLECTRI(i SERVICE: CONNECTED TO UNDERGROUND ELECTRICAL SERVICE. 1 O' PUBLIC UTILITIES EA5EMET ,COK4C. WALK/ / I'll TO SEWER MAIM lim ii, - =Fml SCALE: 1/4" - 1'-0" TRELLI5 5TRUCTURAL NOTE5: 1.) SEE TYPICAL NOTE SHEET 5N AND TYPICAL DETAIL SHEET 5D 1 FOR ADDITIONAL INFORMATION. 2.) DO NOT REMOVE OR MODIFY SUPPORT MEMBERS OR HARDWARE FOR EXISTING FRAMING WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ENGINEER OF RECORD. 5.) ANY DISCREPANCIES BETWEEN FRAMING SHOWN AND FIELD CONDITIONS SHALL BE IMMEDIATELY BROUGHT TO THE ENGINEER OF RECORD. 4.) ALL EXPOSED FRAMING SHALL BE PRESSURE TREATED WITH TREATMENT PROCESS AND APPLICATION APPROPRIATE FOR EXPOSURE ACCORDING TO MFR'S WRITTEN 6UIDELINE5. 5.) WATERPROOFING, FLASHING, DRAINAGE, CORROSION PROTECTION, ETC,. BY OTHERS. 2'-1 O' 20'-2' 2'-6" SQUARE x 12" 2'-6" SQUARE x 12" THICK FOOTING W/#4 THICK FOOTING W/#4 AT b" C/C EACH WAY AT b" C/C EACH WAY N BOTTOM. BOTTOM. (E) 4'-b" SQUARE x 50" THICK FOOTING W/ (9) #4 EACH WRY, TOP 4 BOTTOM. \(E) RESIDENCE, GARAGE E � PORCHES TO REMAIN UNCHANGED. (SHAVED AREA) SCALE: 1/4" - 1'-O" TRELLIS STRUCTURAL NO_F-5_ 1.) SEE TYPICAL NOTE SHEET 5N AND TYPICAL DETAIL SHEET 5D 1 FOR ADDITIONAL INFORMATION. 2.) DO NOT REMOVE OR MODIFY SUPPORT MEMBERS OR HARDWARE FOR EXISTING FRAMING WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ENGINEER OF RECORD. 5.) ANY DISCREPANCIES BETWEEN FRAMING 5HOWN AND FIELD CONDITIONS SHALL BE IMMEDIATELY BROUGHT TO THE ENGINEER OF RECORD. 4.) ALL EXPOSED FRAMING SHALL BE PRESSURE TREATED WITH TREATMENT PROCESS AND APPLICATION APPROPRIATE FOR EXPOSURE ACCORDING TO MFR'S WRITTEN 6UIDELINE5. 5.) WATERPROOFING, FLASHING, DRAINAGE, CORROSION PROTECTION, ETC. BY OTHERS. ERIC JONES - GR ENEAL CONTRACTOR (530) 828-9590 CELL EMAIL ADDRESS: ErikJonesGonstruction®Yahoo.com (E) b"xb" (N) ii W/CICO 1/4: 12 PITCH b"x 1 b" DF# 1 NIMNOW "W-Tm TYP TYP. 2 5D 1 (N) Ii W/CGQ �fl�l�11�N�Iliil�Al mill PA o i♦i4 .'�i♦i I' '.0000♦.•� ' IM 14 100 1 3=24 I N, qla h" kN 11, ME M (E) RESIDENCE, 57ARAl 4 PORGHE5 TO REMAIN UNGHArNGED. (SHADED AREA) .oma•. �_ � � .� � (E) b"xb" i ---------- i i I I I I I I I I PE'rlfvIIT #_ C:UTTE COUNTY DEVEILOPMENT SERVICES REVIEWED FOR CODE COMPLIANCE BY I I i SUMMIT 5TKUCTURAL I;?ll - aT RUG1 URAL eNCGINl G:\Users\Lynn\Documents\chief X8 Plane\EriG Jones - Flaherty Patlo\Flaherty Patio.layout d 383 RIO LINDO AVENUE ♦200, CHICO, GA 95926 OWNER: PATRICK FLAHERTY 4 LORI HEAD (530) 592-4401 WORK (408) 306-1 703 HI5 CELL EMAIL ADDRESS: Ryland65ummltGhico.com EMAIL ADDRESS: pfflaheyahoo.com ARCH E 1 50"x42" WHILE EVERY ATTEMPT HAS BEEN MADE IN THE PREPARATION OF THIS PLAN TO AVOID MISTAKES, THE MAKER CANNOT GUARANTEE AGAINST HUMAN ERROR. BUILDING CONTRACTOR / HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS. yi■■D�IRAFTING BY: M (530) 891-0s$5 9 YGAMORE VALLEY ROAD CNIGo, CALIFORNIA 459'13 LYNNSMITH5 20ATT.NET ERIC .TONES 6ENCRAL CONTRACTOR (580) 828-9590 vC -- c�Q J..lU,�r h K. 12/28/2016 THESE PLANS HAVE BEEN REVIEWED ONLY FOR COMPLIANCE WITH ATTACHED STRUCTURAL CALCULATIONS. THE ENGINEER'5 STAMP ON THIS PLAN 15 VALID ONLY WITH A LETTER SIGNED BY TH15 ENGINEER FOR EACH UNIQUE BUILD. 1•' < < iia Z i o 3: O o q LL q < V ul p[ V O Q w -A ol O uj LL 1L Ali k '1 < V ' V ND til }W AL � to ol Lf m fL f <z<� QCL6CL z ISupN Q W J to LL 0)ILd LI\/A]5LE: 2 -r 5 1 SgFt GARA l 1 145 5gFt CO\/'D PATIO: 90 5gFt FRONT 2_68 SgFt REAR 5 5 6 SgFt TOTAL TRELLIS: 329 5gFt DATE: 12/28/2016 SCALE: SHOWN -278t SHEET a COPYRIGHT 201 6 '" •a LYNN SMITH - DRAFTING 1 99 SYCAMORE VALLEY ROAD, CHICO, CA 95973 s zus.acs" (530) 891-0585 WORK 'A.tt Assessors' maps are prepared fpr leea! proper'y CREATED BY DB CREATED ON 01-15-2008 7a.is s1 q2 assessment purposes NLY. Parcels shown thereon may not REVISED BY DB ,REVISED ON 01-15-2008 - comply with State and local subdivialan ordinances. No fiahility - is assumed for use of informatim shown on anyy Assessors' map. FILE NAME 47-77 EFFECTIVE 2D08-09 ROLL - ' ALL ACREAGES APPRQXIMATE'PER RECORDEII INFORMATI�IJ. Prior Book 47, Pae 71 y Compiled By The Butte Count Assessor's Office LUT F ;Oe000l zpo'� PROPANE TANK: EXISTING X 0 i .-SLOPE"r / PROP05ED TRELLIS:: \ (Ej SEPTIC: A5 PER BUTTE COUNT EALTH DEPARTMENT RE0UIREMFNT5. \ WATER SERVer, CONNECTED TO�k4ATER SERVICE. aALGREF'N MOTES: DURING CONSTRUCTION, ONE OR MORE OF THE FOLLOWING MEASURES SHALL BE IMPLEMENTED TO PREVENT FLOODING OF THE ADJACENT PROPERTY, PREVENT EROSION d RETAIN SOIL RUNOFF ON THE SITE: A.) RETENTION BASINS OF SUFFICIENT 51ZE SHALL BE UTILIZED TO RETAIN STORM WATER ON THE SITE. B.) WHERE STORM WATER 15 CONVEYED TO A PUBLIC DRAINAGE SYSTEM, COLLECTION POINT, GUTTER OR SIMILAR DISPOSAL METHOD, WATER SHALL BE FILTERED BY USE OF A BARRIER SYSTEM, WATTLE OR OTHER METHOD APPROVED BY THE ENFORCING A61i C.) COMPLIANCE WITH A LAWFULLY ENACTED STORM WATER MANAGEMENT ORDINANCE. METHODS TO MANAGE 5URFAGE WATER INCLUDE: SWALES, WATER COLLECTION AND V15POSAL SYSTEMS, FRENCH DRAIN5, WATER RETENTION GARDENS d OTHER WATER MEASURES WHICH KEEP SURFACE WATER AWAY FROM BUILVIN65 AND AID IN GROUNDWATER RECHARGE. EROSION_ CONTROL PLAN: 1.) NO 501L DISTURBANCE SHALL OCCUR PRIOR TO OBTAINING A BUILDING PERMIT OR GRADING PERMIT. 2.) THE CONTRACTOR SHALL BE RE5PON51BLE FOR EROSION CONTROL. 3.) ER05ION CONTROL MEASURES SHALL BE IN PLACE BETWEEN OCT. 15TH d APR. 1 5TH, OR WHEN RAIN 15 FORCA5TED. 4.) SOILS TRACKED OFF 51TE INTO STREETS SHALL BE GLEANED UP AT THE END OF EACH WORK DAY. 5.) INACTIVE SOIL STOCKPILES SHALL BE COVERED. ACTIVE STOCKPILES SHALL BE COVERED PRIOR TO A FORGASTED RAIN EVENT. b.) THE EROSION CONTROL PLAN SHALL BE RE-EVALUATED 4 ADJUSTED ACCORDINGLY A5 THE 51TE CHANGES 4 AFTER RAIN EVENTS. S� 7.) EROSION CONTROL MEA5URE5 SHALL BE MAINTAINED. 8.) PLACE SIGN AT WASHOUT: WASHING OF CONCRETE EQUIP. 6 TOOLS AT ANY OTHER LOCATION THAN A DE516NATED CONCRETE WASHOUT 15 A VIOLATION OF LAW 4 SUBJECT TO FINE. PROPERTY OWNER: • PATRICK FLAHERTY 5 ci 5PYGLA55 ROAD, CHICO, GA 95 9 13 PHONE (408) 506-1-105 CONTRACTOR: • ERIK JONES GONG. DRIVEY+IAY' 2685 VISTAMONT WAY, CHICO, GA 959-15 PHONE(550)828-9590 51TE ADDRESS: NONE ASSIGNED :.< A CONSTRUCTION IO / 1 5/20 5 APPROX END: 2/1 5129 5 / / O' BUILDING SETBACK LINE BLECTRI(i SERVICE: CONNECTED TO UNDERGROUND ELECTRICAL SERVICE. 1 O' PUBLIC UTILITIES EA5EMET ,COK4C. WALK/ / I'll TO SEWER MAIM lim ii, - =Fml SCALE: 1/4" - 1'-0" TRELLI5 5TRUCTURAL NOTE5: 1.) SEE TYPICAL NOTE SHEET 5N AND TYPICAL DETAIL SHEET 5D 1 FOR ADDITIONAL INFORMATION. 2.) DO NOT REMOVE OR MODIFY SUPPORT MEMBERS OR HARDWARE FOR EXISTING FRAMING WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ENGINEER OF RECORD. 5.) ANY DISCREPANCIES BETWEEN FRAMING SHOWN AND FIELD CONDITIONS SHALL BE IMMEDIATELY BROUGHT TO THE ENGINEER OF RECORD. 4.) ALL EXPOSED FRAMING SHALL BE PRESSURE TREATED WITH TREATMENT PROCESS AND APPLICATION APPROPRIATE FOR EXPOSURE ACCORDING TO MFR'S WRITTEN 6UIDELINE5. 5.) WATERPROOFING, FLASHING, DRAINAGE, CORROSION PROTECTION, ETC,. BY OTHERS. 2'-1 O' 20'-2' 2'-6" SQUARE x 12" 2'-6" SQUARE x 12" THICK FOOTING W/#4 THICK FOOTING W/#4 AT b" C/C EACH WAY AT b" C/C EACH WAY N BOTTOM. BOTTOM. (E) 4'-b" SQUARE x 50" THICK FOOTING W/ (9) #4 EACH WRY, TOP 4 BOTTOM. \(E) RESIDENCE, GARAGE E � PORCHES TO REMAIN UNCHANGED. (SHAVED AREA) SCALE: 1/4" - 1'-O" TRELLIS STRUCTURAL NO_F-5_ 1.) SEE TYPICAL NOTE SHEET 5N AND TYPICAL DETAIL SHEET 5D 1 FOR ADDITIONAL INFORMATION. 2.) DO NOT REMOVE OR MODIFY SUPPORT MEMBERS OR HARDWARE FOR EXISTING FRAMING WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ENGINEER OF RECORD. 5.) ANY DISCREPANCIES BETWEEN FRAMING 5HOWN AND FIELD CONDITIONS SHALL BE IMMEDIATELY BROUGHT TO THE ENGINEER OF RECORD. 4.) ALL EXPOSED FRAMING SHALL BE PRESSURE TREATED WITH TREATMENT PROCESS AND APPLICATION APPROPRIATE FOR EXPOSURE ACCORDING TO MFR'S WRITTEN 6UIDELINE5. 5.) WATERPROOFING, FLASHING, DRAINAGE, CORROSION PROTECTION, ETC. BY OTHERS. ERIC JONES - GR ENEAL CONTRACTOR (530) 828-9590 CELL EMAIL ADDRESS: ErikJonesGonstruction®Yahoo.com (E) b"xb" (N) ii W/CICO 1/4: 12 PITCH b"x 1 b" DF# 1 NIMNOW "W-Tm TYP TYP. 2 5D 1 (N) Ii W/CGQ �fl�l�11�N�Iliil�Al mill PA o i♦i4 .'�i♦i I' '.0000♦.•� ' IM 14 100 1 3=24 I N, qla h" kN 11, ME M (E) RESIDENCE, 57ARAl 4 PORGHE5 TO REMAIN UNGHArNGED. (SHADED AREA) .oma•. �_ � � .� � (E) b"xb" i ---------- i i I I I I I I I I PE'rlfvIIT #_ C:UTTE COUNTY DEVEILOPMENT SERVICES REVIEWED FOR CODE COMPLIANCE BY I I i SUMMIT 5TKUCTURAL I;?ll - aT RUG1 URAL eNCGINl G:\Users\Lynn\Documents\chief X8 Plane\EriG Jones - Flaherty Patlo\Flaherty Patio.layout d 383 RIO LINDO AVENUE ♦200, CHICO, GA 95926 OWNER: PATRICK FLAHERTY 4 LORI HEAD (530) 592-4401 WORK (408) 306-1 703 HI5 CELL EMAIL ADDRESS: Ryland65ummltGhico.com EMAIL ADDRESS: pfflaheyahoo.com ARCH E 1 50"x42" WHILE EVERY ATTEMPT HAS BEEN MADE IN THE PREPARATION OF THIS PLAN TO AVOID MISTAKES, THE MAKER CANNOT GUARANTEE AGAINST HUMAN ERROR. BUILDING CONTRACTOR / HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS. yi■■D�IRAFTING BY: M (530) 891-0s$5 9 YGAMORE VALLEY ROAD CNIGo, CALIFORNIA 459'13 LYNNSMITH5 20ATT.NET ERIC .TONES 6ENCRAL CONTRACTOR (580) 828-9590 vC -- c�Q J..lU,�r h K. 12/28/2016 THESE PLANS HAVE BEEN REVIEWED ONLY FOR COMPLIANCE WITH ATTACHED STRUCTURAL CALCULATIONS. THE ENGINEER'5 STAMP ON THIS PLAN 15 VALID ONLY WITH A LETTER SIGNED BY TH15 ENGINEER FOR EACH UNIQUE BUILD. 1•' < < iia Z i o 3: O o q LL q < V ul p[ V O Q w -A ol O uj LL 1L Ali k '1 < V ' V ND til }W AL � to ol Lf m fL f <z<� QCL6CL z ISupN Q W J to LL 0)ILd LI\/A]5LE: 2 -r 5 1 SgFt GARA l 1 145 5gFt CO\/'D PATIO: 90 5gFt FRONT 2_68 SgFt REAR 5 5 6 SgFt TOTAL TRELLIS: 329 5gFt DATE: 12/28/2016 SCALE: SHOWN -278t SHEET a COPYRIGHT 201 6 '" •a LYNN SMITH - DRAFTING 1 99 SYCAMORE VALLEY ROAD, CHICO, CA 95973 s zus.acs" (530) 891-0585 WORK 1. GENERAL 3. CONCRETE / REINFORCING CONTINUED 6. FRAMING / LUMBER CONTINUED 9. DESIGN LOADS A) ALL WORK SHALL CONFORM TO THE 2013 CBC AND ALL APPLICABLE LOCAL CODES. 1) REINFORCEMENT COVER SHALL BE AS FOLLOWS: 6-4 POSTS/TRIMMERS: A) THE STRUCTURE HAS BEEN DESIGNED FOR THE FOLLOWING CRITERIA PER CBC CHAPTER 16, DIVISIONS I, 11, III, AND IV U.N.O.: B) THE ENGINEER (SUMMIT STRUCTURAL DESIGN) HAS PROVIDED AND IS RESPONSIBLE FOR CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO SOIL: 3" A.) SUPPORT: SUPPORT ALL UPPER LEVEL POSTS AND TRIMMERS IN LOWER LEVELS WITH SPECIFIC STRUCTURAL ITEMS ONLY. ALL OTHER REQUIREMENTS OF THE BUILDING CODE CONCRETE WITH SOIL OR WEATHER EXPOSURE: EQUIVALENT FRAMING AND BLOCK OR OTHERWISE FRAME POSTS THROUGH FLOOR SYSTEMS. B) SEISMIC: SEISMIC IMPORTANCE FACTOR: 1 INCLUDING WATERPROOFING, FIREPROOFING, DRAINAGE, HANDICAP ACCESSIBILITY, EGRESS REQUIREMENTS, PARKING, AND ALL OTHER DESIGN REQUIREMENTS NOT SPECIFICALLY SHOWN #5 BARS AND SMALLER 1 %Z" #6 BARS AND LARGER 2" B.) WHERE POSTS WITH COLUMN CAPS OR BEARING PLATES ARE SPECIFIED, THE LOAD IS TO BE MAPPED SPECTAL RESPONSE ACCELERATIONS: Ss = 0.617, S1= 0.276 IN THE STRUCTURAL DESIGN CALCULATIONS, ARE THE RESPONSIBILITY OF THE CONTRACTOR OR CONCRETE WITHOUT SOIL OR WEATHER EXPOSURE: 3/4" TRANSFERRED TO THE FOUNDATION BY VERTICAL GRAIN ONLY, U.N.O. SEISMIC SITE CLASS: D SPECTRAL RESPONSE COEFFICIENTS: SDS = 0.537, SD1= 0.340, Cs = 0.27 OWNER. SHOULD ANY CHANGES BE MADE FROM THE DESIGN AS SPECIFIED IN THESE SEISMIC DESIGN CATEGORY: D DOCUMENTS WITHOUT THE WRITTEN APPROVAL FROM THE ENGINEER, THEN THE ENGINEER J) REINFORCEMENT SHALL BE GRADE 60 PER ASTM A615 U.N.O. LAP BOTTOM REINFORCING (60) 6-6 CONNECTIONS: BASIC SEISMIC -FORCE -RESISTING SYSTEM: LIGHT FRAMED SHEAR WALLS WILL ASSUME NO RESPONSIBILITY FOR ANY ELEMENT OR SYSTEM OF THE STRUCTURE. BAR DIAMETERS U.N.O. AND LAP TOP REINFORCING, PLACED ABOVE 12" OF CONCRETE OR SEISMIC BASE SHEAR: 0.86 KIPS MORE, (80) BAR DIAMETERS U.N.O. A.) HOLES FOR THROUGH BOLTS SHALL BE DRILLED 1/16" OVERSIZE. RESPONSE MODIFICATION FACTOR: R = 2.0 C) THE DRAWINGS AND CALCULATIONS REPRESENT THE FINISHED STRUCTURE, AND, UNLESS SPECIFICALLY NOTED OTHERWISE, DO NOT SHOW THE METHOD OF CONSTRUCTION. THE K) #5 AND LARGER REBAR SHALL NOT BE RE-BENT. B.) ALL BOLTS, NUTS, AND LAG SCREWS SHALL BE PROVIDED WITH FLAT OR MALLEABLE ANALYSIS PROCEDURE USED: EQUIVALENT STATIC FORCE PROCEDURE CONTRACTOR IS RESPONSIBLE FOR THE METHOD OF CONSTRUCTION, AND SHALL PROVIDE ALL WASHERS WHERE BEARING AGAINST WOOD. C) WIND: MEASURES NECESSARY TO PROTECT THE PUBLIC, CONSTRUCTION WORKERS, AND THE L) ALL REINFORCING STEEL AND ANCHOR BOLTS SHALL BE ACCURATELY LOCATED AND WIND SPEED: 110 MPH STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE FORMING, SHORING, ADEQUATELY SECURED IN POSITION BEFORE AND DURING CONCRETE PLACEMENT. C.) ALL BOLTS AND LAG SCREWS SHALL BE TIGHTENED UPON INSTALLATION AND RE -TIGHTENED WIND EXPOSURE: C BRACING, SCAFFOLDING, ETCETERA. BEFORE CLOSING IN OR AT COMPLETION OF JOB. D) IF A PARTICULAR FEATURE OF CONSTRUCTION IS NOT FULLY SHOWN ON THE DRAWINGS OR IN 5. MASONRY D.) LAG SCREWS SHALL BE SCREWED, NOT DRIVEN, INTO PLACE. D) LIVE LOADS: ROOF NA THE CALCULATIONS, THEN IT SHALL BE CONSTRUCTED IN THE SAME CHARACTER AS SIMILAR CONDITIONS THAT ARE SHOWN ON THE DESIGN DOCUMENTS. A) CEMENT MASONRY UNITS SHALL CONFORM TO CBC STANDARD 21-4, GRADE N, TYPE I, AND SHALL BE SINGLE OR DOUBLE OPEN END BOND BEAM UNITS. E) ANY CONDITIONS NOTED AS EXISTING MUST BE FIELD VERIFIED BY THE CONTRACTOR, AND ANY DISCREPANCIES MUST BE BROUGHT TO THE ATTENTION OF THE ENGINEER WITHOUT B) F'm MIN SHALL BE 1,500 PSI WITH COMPLIANCE VERIFIED AS REQUIRED PER CBC SECTION PROCEEDING WITH CONSTRUCTION PRIOR TO THE REVIEW OF THE ENGINEER. 2105.3. F) ALL WATERPROOFING AND FLASHING (ROOFS, FOUNDATIONS, GARAGE FLOORS, ETC...) IS THE C) EACH CELL SHALL BE COMPLETELY FILLED WITH GROUT CONFORMING TO ASTM C279 TYPE S RESPONSIBILITY OF THE CONTRACTOR OR OWNER. WITH A MINIMUM STRENGTH OF 2,000 PSI. G) SHOP DRAWINGS: SHOP DRAWINGS ARE SUPERCEDED BY THE STRUCTURAL DRAWINGS UNDER D) LAP REINFORCING THE GREATER OF 80 BAR DIAMETERS OR T-0". ALL CIRCUMSTANCES. THE GENERAL CONTRACTOR SHALL VERIFY THAT ALL CONSTRUCTION IS IN FULL AGREEMENT WITH THE LATEST STRUCTURAL DRAWINGS. REVIEW OF SHOP DRAWINGS BY E) LOCATE ANCHOR BOLTS WITHIN 2" OF THE CENTER OF A CELL. THE ENGINEER OF RECORD DOES NOT GUARANTEE IN ANY WAY THE THE SHOP DRAWINGS ARE CORRECT, NOR DOES IT INFER THAT THEY SUPERCEDE THE STRUCTURAL DRAWINGS. 6. FRAMING/LUMBER H) WALL FINISH SYSTEMS SUCH AS STUCCO SHALL BE APPLIED OVER FOAM BASE OR OTHER METHOD OF ADEQUATELY ALLOWING THE FINISH TO EXPAND AND CONTRACT WITHOUT 6-1 MATERIALS: CRACKING. THE OWNER OR CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DEFECTS IN THE FINISHES. A.) SHEATHING: 1. ROOF SHEATHING: SEE PLANS 1) SPECIAL INSPECTION: SPECIAL INSPECTION PER SECTION 1701 OF THE CBC SHALL BE PROVIDED 2. FLOOR SHEATHING: SEE PLANS FOR THE FOLLOWING TYPES OF CONSTRUCTION: 3. WALL SHEATHING: SEE PLANS WELDING OF STRUCTURAL OR REINFORCING STEEL EPDXY/MECHANICAL CONCRETE ANCHORS B.) GLUE -LAMS: GLUE -LAMS SHALL BE 24F -V4 U.N.O. WITH A CAMBER OF R=1600' U.N.O. THE SPECIAL INSPECTOR SHALL BE ACCEPTABLE TO THE STRUCTURAL ENGINEER AND BUILDING GLUE -LAMS EXPOSED TO WEATHER MUST BE RATED FOR EXTERIOR USE BY THE MANUFACTURER. DEPARTMENT, SHALL BE ICBO QUALIFIED, AND THEIR EXPERIENCE SHALL BE COMMENSURATE GLUED LAMINATED FABRICATON SHALL BE PERFORMED IN AN APPROVED FABRICATORS SHOP WITH THIS TYPE OF PROJECT. IN ACCORDANCE WITH CBC 2303.1.3, AITC A190.1, AND ASTM D 3737. BEAM INSPECTION CERTIFICATES SHALL BE SUBMITTED TO THE FIELD INSPECTOR PRIOR TO COMPLETION OF FRAME INSPECTION IN ACCORDANCE WITH CBC 1704.2. 2. SITE WORK / FOUNDATIONS C.) MICRO -LAMS: MICRO -LAMS (LAMINATED VENEER LUMBER) SHALL HAVE FB = 3100 PSI AND A) ASSUMED MAXIMUM SOIL BEARING = 1500 PSF PER CBC TABLE 1806.2 (NO SOILS REPORT FV = 285 PSI MIN., AND SHALL BE MANUFACTURED, APPROVED AND IDENTIFIED AS PER NER-481. PROVIDED). D.) SILL PLATES: SILL PLATES SHALL BE PRESSURE TREATED DOUGLAS FIR WITH 1/2" DIAMETER B) BUILDING SITE IS ASSUMED TO BE DRAINED AND FREE OF CLAY OR EXPANSIVE SOIL. ENGINEER ANCHOR BOLTS AND 3" X 3" X.229" PLATE WASHERS LOCATED AT 6'-0" O.C. MAX. WITH HAS NOT MADE A GEOTECHNICAL REVIEW OF SITE, ANY OTHER CONDITIONS ENCOUNTERED ONE BOLT LOCATED V-0" MAXIMUM FROM EACH END OF EACH PIECE. RE -TREAT CUT ENDS MUST BE BROUGHT TO THE ATTENTION OF THE ENGINEER. WHERE REQUIRED. C) THESE CALCULATIONS ASSUME STABLE, UNDISTURBED SOILS AND LEVEL OR STEPPED FOOTINGS. E.) FRAMING LUMBER: ALL FRAMING LUMBER SHALL BE DOUGLAS FIR LARCH AS GRADED BY THE ANY OTHER CONDITIONS SHOULD BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO W.W.P.A. OR W.C.L.I.B. AND SHALL HAVE A MOISTURE CONTENT LESS THAN 19%, U.N.O. THE CONSTRUCTION OF THE FOUNDATIONS. 1. STUDS SHALL BE STUD GRADE OR BETTER. D) ALL FOOTINGS INCLUDING RETAINING WALL FOOTINGS, SPREAD FOOTINGS, WALL FOOTINGS, 2. ALL POSTS SHALL BE DF -L #1 U.N.O. AND GRADE BEAMS SHALL BEAR ON UNDISTURBED SOIL WITH A FOOTING DEPTH BELOW 3. 2X AND 3X RAFTERS SHALL BE DF -L #2 U.N.O. FROSTLINE (12" TO 24" AS PER LOCAL REQUIREMENTS). 4. 2X JOISTS SHALL BE DF -L #2 U.N.O. 5. CONCEALED BEAMS SHALL BE DF -L #2. E) BOTTOM OF ALL FOUNDATION TRENCHES SHALL BE CLEAN AND LEVEL. 6. EXPOSED BEAMS SHALL BE DF -L #1 APPEARANCE GRADE FOHC (4X6 AND LARGER). 7. ALL BEAMS 6X AND LARGER SHALL BE FREE OF HEART CENTER. F) ALL FINISHED GRADE SHALL SLOPE AT A MINIMUM SLOPE OF 5% AWAY FROM ALL FOUNDATIONS A MINIMUM OF 10 FEET HORIZONTAL. F.) NAILS: ALL NAILS SHALL BE COMMON U.N.O. WHERE EXPOSED TO WEATHER OR WITHIN 18" OF FOUNDATION, NAILS SHALL BE GALVANIZED. G) FOUNDATIONS SHALL NOT BE SCALED FROM PLAN OR DETAIL DRAWINGS. G.) BOLTS AND LAG SCREWS: BOLTS AND LAG SCREWS SHALL BE ASTM A-307 U.N.O. AND H) FILL MATERIAL SHALL BE FREE FROM DEBRIS, VEGETATION, AND OTHER FOREIGN SUBSTANCES. PROVIDED NEW AND WITHOUT EXCESSIVE RUST. 1) USE 4" DIAMETER PERFORATED PIPE SUB -DRAIN BEHIND ALL RETAINING WALLS. SLOPE PIPE H.) ALL HARDWARE CALLED SHALL BE SIMPSON STRONG -TIE CO., OR ENGINEER APPROVED TO DRAIN TO DAYLIGHT. EQUIVALENT, INSTALLED PER MANUFACTURER'S RECOMMENDATIONS WITH ALL HOLES FILLED WITH RECOMMENDED FASTENERS. USP HARDWARE MAY BE USED IN LIEU OF SIMPSON J.) FOR FOOTINGS PLACED ON OR ADJACENT TO SLOPES, A GEOTECHNICAL ENGINEER MUST HARDWARE WITH WRITTEN APPROVAL FROM STRUCTURAL ENGINEER OF RECORD. ALL METAL APPROVE FOOTING PLACEMENTS IN VIOLATION OF FIGURE 1808.7.1 OF 2013 CBC. THIS HANGERS, CONNECTORS, AND FASTENERS IN CONTACT WITH PRESSURE TREATED WOOD SHALL ENGINEER SHALL NOT BE LIABLE FOR ANY FOUNDATION NOT IN STRICT CONFORMANCE TO BE STAINLESS STEEL OR OTHERWISE CERTIFIED BY THE MANUFACTURER TO RESIST CORROSION SECTION 1808 OF THE 2013 CBC. CAUSED BY THE SPECIFIC TREATMENT APPLIED TO THE WOOD AND/OR METALS. K.) WHERE LOADING TO EXISTING FOUNDATIONS IS NOT SUBSTANTIALLY INCREASED OR MODIFIED, 6-2 GENERAL FRAMING: NO DESIGN RECOMMENDATIONS HAVE BEEN MADE FOR THE SUITABILITY OF THE EXISTING FOUNDATIONS. ONLY THOSE FOUNDATIONS WHERE LOADS HAVE BEEN ADDED BY A SECOND A.) MINIMUM NAILING: MINIMUM NAILING SHALL BE PER 2013 CBC TABLE 2304.9.1. STORY HAVE BEEN INCLUDED IN THE DESIGN. THE OWNER SHALL BE ADVISED THAT EXISTING FOUNDATIONS MAY NOT BE STRUCTURALLY ADEQUATE AND SETTLEMENT, CRACKING, AND B.) LARGER MEMBERS: ALL FRAMING MEMBERS SPECIFIED IN THESE CALCULATIONS ARE OTHER PROBLEMS ASSOCIATED WITH EXISTING FOUNDATIONS ARE BEYOND THE SCOPE OF THIS MINIMUMS, LARGER MEMBERS MAY BE SUBSTITUTED AT CONTRACTORS OPTION. DESIGN. IF REVIEW OF THE EXISTING FOUNDATIONS IS REQUIRED, A GEOTECHNICAL ENGINEER SHOULD BE CONTACTED TO DETERMINE THE EXTENT AND ADEQUACY OF THE EXISTING, C.) SHRINKAGE: CARE SHALL BE TAKEN TO ALLOW FOR EFFECTS OF SHRINKAGE WHICH COULD UN -MODIFIED PORTIONS OF THE FOUNDATIONS. CAUSE SETTLEMENT OF ROOF AND OR FLOORS AND COULD LEAD TO FAILURE OF ASSOCIATED FRAMING MEMBERS. THE CONTRACTOR SHALL TAKE ALL MEASURES NECESSARY TO PROTECT FRAMING FROM THE EFFECTS OF SHRINKAGE. 3. CONCRETE /REINFORCING D.) ALL STRUCTURAL FRAMING MEMBER WITH EXTERIOR EXPOSURE SHALL BE PRESSURE TREATED A) CONCRETE SHALL HAVE A MINIMUM 28 DAY STRENGTH OF 3,000 PSI (DESIGN BASED ON OR BE OF MATERIAL THAT IS NATURALLY RESISTANCE TO DECAY. 2,500 PSI U.N.O.). 6-3 BEAM FRAMING: C) ALL CEMENT USED SHALL CONFORM TO ASTM C-150 AND SHALL BE TYPE II OR TYPE III LOW ALKALI. A.) BUILT UP BEAMS: ALL BUILT UP, LAMINATED DOUBLE OR MULTIPLE 2X JOISTS AND BEAMS SHALL BE NAILED TOGETHER WITH 16d NAILS AT 6" O.C., T&B U.N.O. D) AGGREGATE SHALL CONFORM TO ASTM C-33 AND SHALL NOT CONTAIN MATERIALS WHICH ARE ALKALI REACTIVE AS DETERMINED BY ASTM C-227, 289, AND 295. IF TEST DATA IS B.) DOUBLE JOISTS: PROVIDE DOUBLE FLOOR JOISTS UNDER PARTITION WALLS RUNNING PARALLEL UNAVAILABLE IN REGARDS TO ALKALI REACTIVE MATERIALS, PROVIDE CEMENT WITH A TO JOIST SPAN AND UNDER ALL LOCATIONS WHERE TUBS MAY BE LOCATED. ADEQUATE MAXIMUM ALKALI CONTENT LESS THAN 0.45% BY WEIGHT. SUPPORT SHALL BE PROVIDED FOR ALL OTHER EQUIPMENT OR FURNISHINGS WHICH MAY NOT BE SHOWN ON THE STRUCTURAL DRAWINGS INCLUDING BUT NOT LIMITED TO: HOT E) CONCRETE EXPOSED TO FREEZING OR THAWING SHALL BE PROTECTED IN ACCORDANCE TO THE WATER HEATER, STOVE, REFRIGERATOR, OVEN, FIRE PLACE ENCLOSURES, WOOD BURNING LATEST EDITION OF THE ACI 318. STOVE, ETCETERA. F) SLABS ON GRADE SHALL BE PER THE CONTRACTOR. SUMMIT STRUCTURAL DESIGN RECOMMENDS C.) BLOCKING: PROVIDE SOLID BLOCKING IN JOIST FRAMING ABOVE ALL SUPPORTS THE FOLLOWING AS A MINIMUM SLAB -ON -GRADE: AT GARAGE SLABS, USE 4" THICK S.O.G. WITH #3 BARS AT 15" O.C. EACH WAY ABOVE MID -DEPTH OF SLAB, OVER MOISTURE BARRIER IN COMPLIANCE WITH ASTM E 1643, OVER 4" AGGREGATE BASE. USE 3-1/2" SLAB WITH#3 AT 15" E.W. ABOVE MID -DEPTH OF SLAB, OR 6X6 WWF ABOVE MID -DEPTH OF SLAB WITH SAME SUB -SLAB BUILDUP AT ALL OTHER AREAS. G) SAW -CUT TOP 3/4" OF SLAB FOR CRACK CONTROL AT INTERVALS NOT TO EXCEED 10'-0" WHERE SLAB IS REINFORCED, SAW CUT AT INTERVALS NOT TO EXCEED 7'-0" WHERE SLAB IS UN -REINFORCED. ABBREVIATIONS Q 0FESSIpNq o AB ANCHOR BOLT K KIPS 010/1 6 8 �No. 78' ADD'L ADDITIONAL L ANGLE / 0/1 ADJ ADJACENT LLH LONG LEG HORIZ.�9T C I V ALT ALTERNATE LLV LONG LEG VERT. FOF CAO� ARCH ARCHITECTURAL LONG LONGITUDINAL BLDG BUILDING LSL LONG SLOTTED HOLE 11/28/16 BLKG BLOCKING LVL LAMINATED VENEER LUMBER BM BEAM MAX MAXIMUM THESE PLANS HAVE BEEN REVIEWED B BOTTOM MB MACHINE BOLTS FOR COMPLIANCE ONLY WITH THE BOTT (B) ATTACHED STRUCTURAL BTF BEAT TO FIT MECH MECHANICAL CALCULATIONS BTWN BETWEEN MFR MANUFACTURER CB CARRIAGE BOLTS MIN MINIMUM CCJ CONTROL JOINT MISC. MISCELLANEOUS CIP CAST -IN-PLACE CONCRETE MTL METAL C1 CONSTRUCTION JOINT (N) NEW CLR CLEAR NS NEAR SIDE CMU CONCRETE MASONRY UNITS NSA NELSON STUD ANCHOR' COL COLUMN NTS NOT TO SCALE CONC CONCRETE OC ON CENTER CONN CONNECTION OD OUTSIDE DIAMETER CONSTR CONSTRUCTION OH OPPOSITE HAND CONT CONTINUOUS OPNG OPENINGw CONTR CONTRACTOR OVS OVERSIZE ROUND HOLE CP COMPLETE PENETRATION PDF POWDER DRIVEN FASTENER CTR CENTER PERP PERPENDICULAR CTSK COUNTERSINK PL PLATE Suite 200 SRio Lindo Ave. DBL DOUBLE PLWD PLYWOOD Sui DF DOUGLAS FIR PLCS PLACES Chico, CA 95926 DF -L DOUGLAS FIR - LARCH PP PARTIAL PENETRATION P. 530.592.4407 DIA DIAMETER PT PRESSURE TREATED SummitChico.com DJ DOUBLE JOIST P/C PRECAST CONCRETE EA EACH P/T POST -TENSIONED EF EACH FACE REINF REINFORCEMENT EL ELEVATION (DATUM) REQ'D REQUIRED ELEV ELEVATION (VIEW) OR ELEVATOR SC SLIP CRITICAL EN EDGE NAILING SEOR STRUCTURAL ENGINEER OF EQ EQUAL RECORD ES EACH SIDE SHTG SHEATHING (E) EXISTING SIM SIMILAR EXP EXPANSION SOG SLAB -ON -GRADE EXT EXTERIOR STD STANDARD EW EACH WAY STIFF STIFFENER FF FINISH FLOOR STL STEEL FIN FINISH SQ SQUARE F1 FLOOR JOIST SS STAINLESS STEEL FLR FLOOR SWS SHEAR WALL SCHEDULE J FNDN FOUNDATION SYM SYMMETRICAL FOHC FREE OF HEART CENTER T&B TOP & BOTTOM FOS FACE OF STUD TO(P) TOP OF (PLYWOOD) Uj Q FS FAR SIDE TOC TOP -OF -CONCRETE FTG FOOTING TOF TOP -OF -FOOTING 0 GA GAUGE TOS TOP -OF -STEEL GALV GALVANIZED TOW TOP -OF -WALL V, Q GLB GLUE -LAM BEAM TN TOE NAIL Vi U HDG HOT DIPPED GALVANIZED TYP TYPICAL Q N HDR HEADER UNO UNLESS NOTED OTHERWISE j O HGR HANGER (SIMPSON) VERT VERTICAL U U HORIZ HORIZONTAL WP WORKPOINT _ ID INSIDE DIAMETER WWF WELDED WIRE FABRIC U INT INTERIOR W/ WITH Ln JST JOIST W/O WITHOUT Uj N JT JOINT Rt Cy)LjL REVISIONS: BUTTE COUNTY DEVELOPMENT SERVICES DATE: 11/2.8/16 REVIEWED FOR CODE COMPLIANCE SCALE: NTS DRAWN BY: RKB JOB NUMBER: 16-351 SHEET: S f V -- - - - - -L -- - -- - - ---- - -- - -------------._..__... - - _ --- - -._ ..-- ----- -� —LL G.. V ; i JI ll� J VV 1' 1L L ll 1 CCOQ CENTERED ON (E) COLUM >-3/1-67-� 2" NON—SHRINK GROUT (3000 PSI AT 1 DAY, 5000 PSI AT 28 DAYS) — 0 I � ^ Z BAR CONCRETE STRENGTH Fc = PSI 3000 4000 5000 6000 SIZE #3 28 24 22 20 21 18 17 16 #4 37 32 29 26 28 25 22 20 #5 46 40 36 33 o_ �0 36 31 28 25 #6 56 48 43 39 43 37 33 30 #7 81 70 63 57 62 54 48 44 #8 93 80 72 65 71 62 55 50 #9 104 90 81 74 BENDS 80 69 62 57 #10 116 100 90 82 89 77 69 63 #11 127 110 99 90 98 85 76 69 TOP BARS 2 OTHER BARS NOTES Q1 INCREASE LAP LENGTHS 30% FOR LIGHT WEIGHT CONCRETE (115 PCF MAX) AND 33% AT 4 BAR BUNDLES. 02 TOP BARS ARE HORIZ. BARS WITH MORE THAN 12" OF WET CONCRETE PLACED BELOW. ® MINIMUM CLEAR COVER > dB AND MINIMUM CLEAR SPACING > 2dB. INCREASE LAP LENGTHS 50% IF MINIMUMS NOT SATISFIED. ("dB" = BAR DIAMETER) ® CLASS B SPLICE SHALL BE USED UNO. CLASS A SPLICE = 77% OF CLASS B SPLICE AND MAY BE USED WHERE SPECIFICALLY NOTED IN PLANS AND DETAILS �5 LAP LENGTHS INDICATED ARE IN INCHES. TYPICAL REBAR LAP SCHEDULE CLASS B IO NO SCALE SDI V-11 5/8" SQ. BASE PLATE 3/4" X 12" SQ. WITH (4) 3/4" DIA. THREADED ROD ANCHORS WITH 12" EMBED IN SIMPSON SET—XP EPDXY AND DBL NUT. LOCATE AND AVOID ALL (E) REINFORCING PRIOR TO DRILLING. INSTALL EPDXY PER MFR'S RECOMMENDATIONS (E) CMU COLUMN I ( I (E) VENEER AND CONCRETE CAP, TYP ---q OF COLUMN NOTES: 1.) ANY DISCREPANCIES BETWEEN EXISTING STRUCTURE SHOWN AND FIELD CONDITION SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ENGINEER OF RECORD. 2.) BRACE FRAMING AS REQUIRED DURING CONSTRUCTION. 3.) CORROSION PROTECTION, FLASHING, WATERPROOFING, AND DRAINAGE BY OTHERS. 4.) OBTAIN SPECIAL INSPECTION FOR EPDXY ANCHORS WHERE REQUIRED BY BUILDING DEPARTMENT. TYPICAL (E) COLUMN DETAIL F8 NO SCALE �Dl 900 HOOK —�` "D" l____1350 HOOK TYP. a BAR SIZE INSIDE DIAMETER "D" #3, #4, #5 4d #6, #7. #8 6d STIRRUPS AND TIES 4d o_ �0 900 HOOK 2 1/2" M v' � N r- -o '**�1800 HOOK BAR SIZE INSIDE DIAMETER "D" #3, #4, #5, #6, #7, #8 6d #9, #101 #11 8d #14, #18 10d HOOKS AND BENDS SEE LAP SCHEDULE FOR CONCRETE OR GENERAL NOTES FOR MASONRY 6 OFFSET AND SPLICES TYPICAL REBAR BENDING DETAIL 7 NO SCALE S D I NOTE: FLASHING, WEATHER TREATMENT, AND CORROSION PROTECTION BY OTHERS. LATTICE MEMBER AND JOIST PER PLAN WITH (2) ATTACHMENT PER 1/4- DIA SDS TOE—SCREWS CONTRACTOR \ WITH 3 1/2- EMBED IN /BEAM BELOW, TYP BEAM PER PLAN TYPICAL TRELLIS DETAIL NO SCALE POST CAP PER PLAN O (3) 1/4- DIA. SDS SCREWS WITH 4" MIN EMBED IN BEAM, TYP 3 SDI PER ARCH BEAM PER PLAN \ 3 1/2-, TYP z 0 4" MIN, TYP (V 6X DF#1 BRACE SAWN FROM SOLID BEAM, TYP (2) 1/4" DIA. SDS STAGGER SCREWS TO SCREWS WITH 4" MIN AVOID CONFLICT, TYP EMBED IN POST, TYP 3" MIN, TYP NOTES: 1.) BRACE FRAMING AS REQUIRED DURING CONSTRUCTION. POST PER PLAN 2.) WEATHERPROOFING, FLASHING AND CORROSION PROTECTION BY OTHERS. 3.) ADDITIONAL FRAMING BY OTHERS NOT SHOWN FOR CLARITY. SEE PLANS AND DETAILS BY OTHERS FOR ADDITIONAL INFORMATION. 4.) PRE—DRILL SDS SCREW HOLES 5/32" AS REQUIRED TO AVOID SPLITTING. TYPICAL KNEE BRACE DETAIL NO SCALE 1'-11 5/8" SQ. COLUMN X3/4" KNIFE PLATE X 3" WIDTH X 2'-2 1/2" LENGTH, PER PLAN AT CENTERLINE OF COLUMN, WITH (2) 3/4" DIA. THRU TYP BOLTS WITH 1/4" THICK X 3" SQ. WASHERS EACH END -�- 6" I Y 1/4" PLATE X COLUMN BASE A ( DIM'S WITH SLOT AT KNIFE PLATE 2" NON—SHRINK GROUT (3000 PSI AT 1 DAY, 5000 PSI AT 28 DAYS) .._ 1 1/2" CLR. VENEER AND ATTACHMENT BY OTHERS, TYP. I Qx ((SOG, I ISOLATE FROM COLUMN/COLUMN BASE AS REQ'D #4 HOOPS T" 12" A 6 O.C. 1 1/2- = 0 1/2" I 1 1 /2" CLR., TYP CLR., TYP Q ^I ISOLATION 3/4" DIA THREADED ROD X 6" #4 TIES AT 6" O.C., a a JOINT, LENGTH, CENTERED ON KNIFE PLATE, TYP E.S. WITH NUT E.S. OF KNIFE PLATE TYPICAL. OFFSET UNDISTURBED w ? VERTS AND TIES NATURAL GRADE, TYP� a OUGHEN SURFACE KNIFE PLATE AS 1/4" AMPLITUDE! = 7111—ml _ (I (10) #4 VERTS z #4 AT 6" O.C. EACH WAY o 1 3" CLR., TYP ' FOOTING PER PLAN EQUAL, TYP EQUAL, TYP OF FTG/COLUMN ABOVE NOTE: CORROSION PROTECTION, FLASHING, WATERPROOFING, AND DRAINAGE BY OTHERS. TYPICAL SPREAD FOOTING DETAIL NO SCALE 1" h CLR. 2 SDI t ms's E COUNTY pEVEL(5'MENT S'FRVICES REVIEWED FOR �OOE COMPLIANCE SDI Q�OFESSION� K �--A� L,jcNo. 75688' * 6/ 0/18 'sl gTFOF CAS 11/28/16 THESE PLAINS HAVE BEEN REVIEWED FOR COMPLIANCE ONLY WITH THE ATTACHED STRUCTURAL CALCULATIONS x� u 10, E 383 Rio Lindo Ave. Suite 200 Chico, CA 95926 P. 530.592.4407 SummitChico.com uli <( Q V) V 1 O 0 V C _ In V Uj (N rn U. Aft umi Lmi EMMI F- U :D Aft ANP w 11 REVISIONS: DATE: 11/28/16 SCALE: NTS DRAWN BY: RKB JOB NUMBER: 16-351 SHEET: S DI •�uT7F• .���B�[►t1Qotulty Department of Development Services ,UN FORM NO • �� s - DFVELOPi T PERMIT CENTER DBP -06 •� . FR�,t ounty Center Drive, Oroville, CA 95965 EVELOPA4EINT! oUn Main Phone (530) 538-7601 Fax (530) 538-7785 S E RAV CE Nv%v%v.butlecou ntv.neUdds PLAN CHANGES RECHECK, OR RETURN Owner's Name: Contact Person Name: Contact email: TAe 5 ( 01nS Contact Phone Number: 5730 CI L ES % c) Date Submitted: Permit Number:VAssessor's Parcel Number: 0 - d 0 '❑ COMPLETE SET OF PLANS ❑ PARTIAL SET OR PAGES OF PLANS (LIST PAGES BELOW) Please check any that apply: ❑ Response to Plan Check Letter? ❑ Response to Building Inspection Correction Notice? ❑ Is there additional square footage? ❑ Is unfinished area being in -filled or completed? 0 Other: LIST OF ITEMS SUBMITTED 2. F-,,, t 4-- (+w? CA 3. 4. 5. Minimum 1 hour plan change fee to be collected at time of submission. Plans Examiner will determine if additional plan checking fees are required: ❑ Minimum $127.00 paid ❑ Additional Fee Amount Due: K:\NEW_WEBSITE\Building\Building Forms & Documents\2014\2014 Forms - Comp1eted\DBP\DBP- 06_Plan_Change_Form_REV'D_8.13.14_AKM.doc Page 1 of 1 383 Rio Lindo Ave, Chico, CA 95926 p, (530) 592-4407 www.summitchico.com Client: Eric Jones, Eric Jones Construction Project: Flaherty Trellis Address: 3942 Spyglass Road, Chico, CA BUTTE COUNTY QY JUN 2 7 2017__#/L. DEVELOPMENT BtJTTE COUNTY DEVELOPMENT SERVICES SERVICES REVIEWED FOR COMPLIANCE C C BY EXP. CrA �F 7 /1117 Note: Summit Structural Design (SSD) is riot responsible for on-site inspection to assure compliance with the standards, sizes., materials, or workmanship specified herein. SSD is not responsible for any structural element or system not specifically noted in this set of specifications/calculations unless authorized in writing by SSD. Workmanship shall be of the highest quality and in all cases shall follow accepted construction practice, the latest edition of the California Building Code, and local building department standards. --= - I- _ _ Summit Structural Design _ PROJECT. Flaherty Trellis STRUCTURAL NOTES 1. GENERAL A) ALL WORK SHALL CONFORM TO THE 2013 CBC AND ALL APPLICABLE LOCAL CODES, B) THE ENGINEER (SUMMIT STRUCTURAL DESIGN) IS RESPONSIBLE FOR -THE STRUCTURAL ITEMS IN THE PLANS ONLY, THE GENERAL CONTRACTOR SHALL VERIFY THAT ALL CONSTRUCTION IS IN FULL AGREEMENT WITH THE LATEST, BUILDING DEPARTMENT APPROVED, STRUCTURAL DRAWINGS. SHOULD ANY CHANGES BE MADE FROM THE DESIGN AS SPECIFIED IN THESE CALCULATIONS WITHOUT THE WRITTEN APPROVAL FROM THE ENGINEER, THEN THE ENGINEER WILL ASSUME NO RESPONSIBILITY FOR ANY ELEMENT OR SYSTEM OF THE STRUCTURE. C) THE DRAWINGS AND CALCULATIONS REPRESENT THE FINISHED STRUCTURE, AND, UNLESS SPECIFICALLY NOTED OTHERWISE, DO NOT SHOW THE METHOD OF CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR THE METHOD OF CONSTRUCTION, AND SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE PUBLIC, CONSTRUCTION WORKERS, AND THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE FORMING, SHORING, BRACING, SCAFFOLDING, ETC. D) IF A PARTICULAR FEATURE OF CONSTRUCTION IS NOT FULLY SHOWN ON THE DRAWINGS OR IN THE CALCULATIONS, THEN IT SHALL BE CONSTRUCTED IN THE SAME CHARACTER AS SIMILAR CONDITIONS THAT ARE SHOWN ON THE DESIGN DOCUMENTS. E) ANY CONDITIONS NOTED AS EXISTING MUST BE FIELD VERIFIED BY THE CONTRACTOR, AND ANY DISCREPANCIES MUST BEBROUGHT TOTHE ATTENTION OF THE ENGINEER WITHOUT PROCEEDING WITH CONSTRUCTION PRIOR TO THE REVIEW OF THE ENGINEER. F) ALL WATER PROOFING AND FLASHING (ROOFS, FOUNDATIONS, GARAGE FLOORS, ETC...) IS THE RESPONSIBILITY OF THE CONTRACTOR OR OWNER. G) SPECIAL INSPECTION: SPECIAL INSPECTION PER SECTION 1701 OF THE CBC SHALL BE PROVIDED FOR THE FOLLOWING TYPES OF CONSTRUCTION: WELDING OF STRUCTURAL OR REINFORCING STEEL EPDXY/MECHANICAL CONCRETE ANCHORS THE SPECIAL INSPECTOR SHALL BE ACCEPTABLE TO THE STRUCTURAL ENGINEER AND BUILDING DEPARTMENT, SHALL BE ICBO QUALIFIED, AND THEIR EXPERIENCE SHALL BE COMMENSURATE WITH THIS TYPE OF PROJECT. 2. SITE WORK / FOUNDATIONS A) ASSUMED MAXIMUM SOIL BEARING = 1,500 PSF PER CBC TABLE 1804,2, B) BUILDING SITE IS ASSUMED TO BE DRAINED AND FREE OF CLAY OR EXPANSIVE SOIL. ENGINEER HAS NOT MADE A GEOTECHNICAL REVIEW OF SITE, ANY OTHER CONDITIONS ENCOUNTERED MUST BE BROUGHT TO THE ATTENTION OF THE ENGINEER. C) THESE CALCULATIONS ASSUME STABLE, UNDISTURBED SOILS AND LEVEL OR STEPPED FOOTINGS. ANY OTHER CONDITIONS SHOULD BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO THE CONSTRUCTION OF THE FOUNDATIONS. D) ALL FOOTINGS INCLUDING RETAINING WALL FOOTINGS, SPREAD FOOTINGS, WALL FOOTINGS, AND GRADE BEAMS SHALL BEAR ON UNDISTURBED SOIL WITH A FOOTING DEPTH BELOW FROSTLIKE. E) BOTTOM OF ALL FOUNDATION TRENCHES SHALL BE CLEAN AND LEVEL. F) ALL FINISHED GRADE SHALL SLOPE AT A MINIMUM SLOPE OF 5% AWAY FROM ALL FOUNDATIONS A MINIMUM OF 10 FEET HORIZONTAL. G) FOUNDATIONS SHALL NOT BE SCALED FROM PLAN OR DETAIL DRAWINGS. li) FILL MATERIAL SHALL BE FREE FROM DEBRIS, VEGETATION, AND OTHER FOREIGN SUBSTANCES, AND SHALL BE COMPACTED A MINIMUM OF 90%. I) USE 4" DIAMETER PERFORATED PIPE SUB -DRAIN BEHIND ALL RETAINING WALLS, SLOPE PIPE TO DRAIN TO DAYLIGHT. J) FOR FOOTINGS PLACED ON OR ADJACENT TO SLOPES, A GEOTECHNICAL ENGINEER MUST APPROVE FOOTING PLACEMENTS IN VIOLATION OF FIGURE 1808.7.1 OF THE 2013 CBC. THIS ENGINEER SHALL NOT BE LIABLE FOR ANY FOUNDATION NOT IN STRICT CONFORMANCE TO SECTION 1808 OF THE 2013 CBC. K) WHERE LOADING TO EXISTING FOUNDATIONS IS NOT SUBSTANTIALLY INCREASED OR MODIFIED, NO DESIGN RECOMMENDATIONS HAVE BEEN MADE FOR THE SUITABILITY OF THE EXISTING FOUNDATIONS. ONLY THOSE FOUNDATIONS WHERE LOADS HAVE BEEN ADDED BY ASECOND STORY HAVE BEEN INCLUDED IN THE DESIGN, THE OWNER SHALL BE ADVISED THAT EXISTING FOUNDATIONS MAY NOT BE STRUCTURALLY ADEQUATE AND SETI LEMENT, CRACKING, AND OTHER PROBLEMS ASSOCIATED WITH EXISTING FOUNDATIONS ARE BEYOND THE SCOPE OF THIS DESIGN. IF REVIEW OF THE EXISTING FOUNDATIONS IS REQUIRED, A GEOTECHNICAL ENGINEER SHOULD BE CONTACTED TO DETERMINE THE EXTENT AND ADEQUACY OF THE EXISTING, UN -MODIFIED PORTIONS OF THE FOUNDATIONS AND UNDERLYING SOILS. 4. CONCRETE / REINFORCING A) CONCRETE SHALL HAVE A MINIMUM 28 DAY STRENGTH OF 3,000 PSI (DESIGN BASED ON 2,500 PSI U.N.O.). C) ALL CEMENT USED SHALL CONFORM TO ASTM C-150 AND SHALL BE TYPE II OR TYPE III LOW ALKALI, D) AGGREGATE SHALL CONFORM TO ASTM C-33 AND SHALL NOT CONTAIN MATERIALS THAT ARE ALKALI REACTIVE AS DETERMINED BY ASTM C-227, 289, AND 295. IF TEST DATA IS UNAVAILABLE IN REGARDS TO ALKALI REACTIVE MATERIALS, PROVIDE CEMENT WITH A MAXIMUM ALKALI CONTENT LESS THAN 0.45% BY WEIGHT. E) CONCRETE EXPOSED TO FREEZING OR THAWING SHALL BE PROTECTED IN ACCORDANCE TO THE LATEST EDITION OF ACI 318. F) SLABS ON GRADE SHALL BE PER THE CONTRACTOR, SUMMIT STRUCTURAL DESIGN RECOMMENDS THE FOLLOWING AS A SUITABLE SLAB -ON -GRADE: AT GARAGE SLABS, USE 4" THICK S.O.G. WITH #3 BARS AT 15" O.C. EACH WAY ABOVE MID -DEPTH OF SLAB OVER 2" SAND, OVER MOISTURE BARRIER, OVER 4" AGGREGATE BASE. USE 3-1/2" SLAB WITH 43 AT 15" E.W, ABOVE MID -DEPTH OF SLAB, OR 6X6 WWF ABOVE MID -DEPTH OF SLAB WITH SAME SUB -SLAB BUILDUP AT ALL OTHER AREAS, G) SAW -CUT TOP %" OF SLAB FOR CRACK CONTROL AT INTERVALS NOT TO EXCEED 16'-0" WHERE SLAB IS REINFORCED, SAW CUT AT INTERVALS NOT TO EXCEED 7'-0" WHERE SLAB IS UN -REINFORCED. 1) REINFORCEMENT COVER SHALL BE AS FOLLOWS: CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO SOIL: 3" CONCRETE WITH SOIL OR WEATHER EXPOSURE: #5 BARS AND SMALLER: 1 %" 46 BARS AND LARGER: 2" CONCRETE WITHOUT SOIL OR WEATHER EXPOSURE: %" J) REINFORCEMENT SHALL BE GRADE 60 PER ASTM A615 U.N.Q. LAP BOTTOM BARS 60 BAR DIAMETERS U.N.O, AND LAP TOP BARS, PLACED ABOVE 12" OF CONCRETE OR MORE, 80 BAR DIAMETERS U.N,O. K) #5 AND LARGER REBAR SHALL NOT BE RE-BENT. L) ALL REINFORCING STEEL AND ANCHOR BOLTS SHALL BE ACCURATELY LOCATED AND ADEQUATELY SECURED IN POSITION BEFORE AND DURING CONCRETE PLACEMENT. 5. MASONRY A) CEMENT MASONRY UNITS SHALL CONFORM TO ASTM C90, AND SHALL BE SINGLE OR DOUBLE OPEN END BOND BEAM UNITS. B) fm MIN SHALL BE 1,500 PSI WITH COMPLIANCE VERIFIED AS REQUIRED PER CBC SECTION 2105.3. A CERTIFICATE OF COMPLIANCE VERIFYING TESTING AND ACCEPTANCE PER ASTM 6 140 FOR THE CMU BLOCK SHALL BE PROVIDED FOR INSPECTION AND REVIEW PRIOR TO PLACING THE MASONRY. C) EACH CELL SHALL BE COMPLETELY FILLED WITH GROUT CONFORMING TO ASTM C476 TYPE'S WITH A MINIMUM STRENGTH OF 2,000 PSI. D) MAXIMUM BED JOIST THICKNESS = 5/8" E) LAP REINFORCING THE GREATER OF 60 BAR DIAMETERS OR 2'-0". F) LOCATE ANCHOR BOLTS WITHIN 2" OF THE CENTER OF A CELL. 6. FRAMING/LUMBER 6-1 MATERIALS: A.) SHEATHING: 1. ROOF SHEATHING: Y" APA RATED 32/16 EXPOSURE 1, STRUCTURAL SHEATHING WITH FACE GRAIN PERPENDICULAR TO FRAMING, STAGGER PANELS AND NAIL. WITH 8d AT 6" O.C. EDGE, 12" O.C. FIELD U.N.O. PROVIDE 1/8" GAP AT ALL PANEL EDGES U,N.O. BY PANEL MANUFACTURER. 2, FLOOR SHEATHING: %" APA RATED 48/24 WITH FACE GRAIN PERPENDICULAR TO FRAMING, STAGGER PANELS AND NAIL WITH 10d AT 6" O,C. EDGE 10" O.0 FIELD, GLUE AND NAIL TO ALL SUPPORTS. PROVIDE 1/8" GAP AT ALL PANEL EDGES U.N.O. BY PANEL MANUFACTURER. 3. WALL SHEATHING: SEE PIANS 4. ANY SHEATHING WITH EXTERIOR EXPOSURE SHALL BE OF EXTERIOR TYPE, B.) GLUE -LAMS: GLUE -LAMS SHALL BE 24F -V4 U.N.O. WITH A CAMBER OF R=1600' U.N.O. GLUE -LAMS EXPOSED TO WEATHER MUST BE RATED FOR EXTERIOR USE BY THE MANUFACTURER. FLASHING AND WATERPROOFING OF EXPOSED ENDS SHALL BE PROVIDED BY THE CONTRACTOR TO PREVENT DECAY. GLUED LAMINATED FABRICATION SHALL BE PERFORMED IN AN APPROVED FABRICATOR'S SHOP IN ACCORDANCE WITH CBC 2303.1.3, AITC A1,90.1 AND ASTM D 3737. BEAM INSPECTION CERTIFICATES SHALL BE SUBMITTED TO THE FIELD INSPECTOR PRIOR TO COMPLETION OF FRAME INSPECTION IN ACCORDANCE WITH CBC 1704.2. Summit Structural De ECT: Flahe C.) MICRO -LAMS: MICRO -LAMS (LAMINATED VENEER LUMBER) SHALL HAVE FB = 3100 PSI & FV = 285 PSI MIN., AND SHALL BE MANUFACTURED,. APPROVED AND IDENTIFIED AS PER NER-481 C2.) PARALAMS: PSL'S (PARALLEL STRAND LUMBER) SHALL HAVE FB = 2900 PSI & FV = 290 PSI MIN., AND SHALL BE MANUFACTURED, APPROVED AND IDENTIFIED AS PER NER-481 D.) SILL PLATES: SILL PLATES SHALL BE PRESSURE TREATED DOUGLAS FIR WITH 1/2" DIAMETER ANCHOR BOLTS AND 3" X 3" X .229" THICK PLATE WASHERS LOCATED AT 6'-0" O.C. MAX. WITH ONE BOLT LOCATED 1'-0" MAXIMUM FROM EACH END OF EACH PIECE. AT SHEAR WALL LOCATIONS, SILLS SHALL BE 3X MATERIAL UNO PER PLANS AND DETAILS. E.) FRAMING LUMBER: ALL FRAMING LUMBER SHALL BE DOUGLAS FIR LARCH AS GRADED BY THE W.W,P.A. OR W.C.L.LB. AND SHALL HAVE',A MOISTURE CONTENT LESS THAN 19%, U.N.D. 1. STUDS SHALL BE STUD GRADE OR BETTER, 2. ALL POSTS SHALL BE DF -L #1 U.N.C. 3. 2X AND 3X RAFTERS SHALL BE DF -L #2 U.N.O. 4, 2X JOISTS SHALL BE DF -L'#2 U.N.O. S, CONCEALED BEAMS SHALL BE DF -L 42 6. EXPOSED BEAMS SHALL 6E DF -L #1 APPEARANCE GRADE FREE OF HEART CENTERS (4X6 AND LARGER) F.) NAILS: ALL NAILS SHALL BE COMMON U.N.O. WHERE EXPOSED TO WEATHER OR WITHIN 18" OF FOUNDATION, NAILS SHALL BE HOT DIPPED GALVANIZED. G.) BOLTS AND LAG SCREWS: BOLTS AND LAG SCREWS SHALL BE ASTM A-307 U.N.O, AND PROVIDED NEW AND WITHOUT EXCESSIVE RUST., BOLTS EXPOSED TO WEATHER SHALL BE GALVANIZED. H.) ALL HARDWARE CALLED SHALL BE SIMPSON STRONG -TIE CO., OR ENGINEER APPROVED EQUIVALENT, INSTALLED PER MANUFACTURER'S RECOMMENDATIONS WITH ALL HOLES FILLED WITH RECOMMENDED FASTENERS I.) ALL METAL FASTENERS IN CONTACT WITH PRESSURE TREATED WOOD SHALL BE STAINLESS STEEL OR OTHERWISE CERTIFIED BY THE MANUFACTURER TO RESIST CORROSION CAUSED BY THE SPECIFIC TREATMENT APPLIED TO WOOD. J.) MANUFACTURED "I" JOISTS; MANUFACTURED i JOISTS (SUCH AS TRUSS JOISTS) SHALL BE INSTALLED PER THE MANUFACTURES RECOMMENDATIONS USING A DEFLECTION LIMIT OF L/480 U.N.O. USE A MANUFACTURED 1-1/4" RIM BOARD (SUCH AS TIMBER STRAND) WITH ALL "I" JOISTS. USE A DOUBLE RIM OR J LVL RIM AT ALL LOCATIONS WHERE LEDGERS ARE USED (SUCH AS DECK LEDGERS). 6-2 GENERAL FRAMING A.) MINIMUM NAILING: MINIMUM NAILING SHALL BE PER 2013 CBCTABLE 2304.9.1. B.) LARGER MEMBERS: ALL FRAMING MEMBERS SPECIFIED IN THESE CALCULATIONS ARE MINIMUMS; LARGER MEMBERS MAY BE SUBSTITUTED AT CONTRACTOR'S OPTION. C.) SHRINKAGE: CARE SHALL BETAKEN TO ALLOW FOR EFFECTS OF SHRINKAGE, WHICH COULD CAUSE SETTLEMENT OF ROOF AND OR FLOORS AND COULD LEAD TO FAILURE OF ASSOCIATED FRAMING MEMBERS, THE CONTRACTOR SHALLTAKE ALL MEASURES NECESSARY TO PROTECT FRAMING FROM THE EFFECTS OF SHRINKAGE, 6-3 BEAM FRAMING A.) BUILT UP BEAMS: ALL BUILT UP, LAMINATED DOUBLE OR MULTIPLE 2X JOISTS AND BEAMS SHALL BE NAILED TOGETHER WITH 16d NAILS AT 6" O.C., T&B U.N.O. B.) DOUBLE JOISTS: PROVIDE DOUBLE FLOOR JOISTS UNDER PARTITION WALLS RUNNING PARALLEL TO JOIST SPAN AND UNDER ALL LOCATIONS WHERE TUBS MAY BE LOCATED, ADEQUATE SUPPORT SHALL BE PROVIDED FOR ALL OTHER EQUIPMENT OR FURNISHINGS WHICH MAY NOT BE SHOWN ON THE STRUCTURAL DRAWINGS INCLUDING BUT NOT LIMITED TO: HOT WATER HEATER, STOVE, REFRIGERATOR, OVEN, FIRE PLACE ENCLOSURES, WOOD BURNING STOVE, ETC... C.) BLOCKING: PROVIDE SOLID BLOCKING IN JOIST FRAMING ABOVE ALL SUPPORTS AND MIDSPAN OF JOISTS SPANNING GREATER THAN 10'-0" 6-4 POSTS/TRIMMERS A.) SUPPORT: SUPPORT ALL UPPER LEVEL POSTS AND TRIMMERS IN LOWER LEVELS WITH EQUIVALENT FRAMING AND BLOCK OR OTHERWISE FRAME POSTS THROUGH FLOOR SYSTEMS. B.) WHERE POSTS WITH COLUMN CAPS OR BEARING PLATES ARE SPECIFIED, THE LOAD IS TO BE TRANSFERRED TO THE FOUNDATION BY VERTICAL GRAIN ONLY, U.N.O. 6-6 CONNECTIONS A.) HOLES FOR THROUGH BOLTS SHALL BE DRILLED 1/16" OVERSIZE. B.) ALL BOLTS, NUTS, AND LAG SCREWS SHALL BE PROVIDED WITH FLAT OR MALLEABLE WASHERS WHERE BEARING AGAINST WOOD. Su O C.) ALL BOLTS AND LAG SCREWS SHALL BE TIGHTENED UPON INSTALLATION AND RE -TIGHTENED BEFORE CLOSING IN OR AT COMPLETION OF JOB, D.) LAG SCREWS SHALL BE SCREWED, NOT DRIVEN, INTO PLACE. E,) FASTENERS IN PRESERVATIVE OR FIRE RETARDANT TREATED WOOD SHALL BE HOT DIPPED GALVANIZED, 7, STEEL 7,1 STRUCTURAL STEEL A.) STRUCTURAL STEEL: ROLLED STEEL SHAPES, PLATES, AND BARS SHALL CONFORM TO ASTM A-36. WIDE FLANGE SHAPES SHALL CONFORM TO ASTM A-992. B.) STRUCTURAL TUBES: STRUCTURAL TUBES SHALL CONFORM TO ASTM A-500 GRADE B. C.) ALL WELDING SHALL BE ELECTRIC ARC WELDING, AND SHALL BE PERFORMED ONLY BY EXPERIENCED, QUALIFIED WELDERS. ELECTRODES SHALL BE E60 XX FOR METAL DECK AND E70 XX OTHERWISE, UNLESS SPECIFICALLY NOTED OTHERWISE. WELDING SHALL CONFORM TO AWS D1,1. D.) UNSPECIFIED WELDS: WELDS NOT SPECIFIED SHALL BE CONTINUOUS FILLET WELDS. WELD SIZE SHALL BE PER AISC SPECIFICATIONS FOR THE THICKER PART OF THE JOINT. E♦) ALL STEEL SHALL BE SHOP PAINTED, UNLESS ENCASED IN CONCRETE, GROUTED MASONRY, OR SPRAYED FIREPROOFING, UNLESS SPECIFICALLY NOTED ON THE DRAWINGS. F.) BOLTS AND LAG SCREWS: BOLTS AND LAG SCREWS SHALL BE ASTM A-307 U.N.O. AND PROVIDED NEW AND WITHOUT EXCESSIVE RUST, 9. DESIGN LOADS A) ALL DESIGN LOADS ARE PER CBC CHAPTER 16, DIVISIONS I, 11, III, AND IV U.N,O, B) ROOF LIVE LOAD: NA C) SEISMIC ZONE: D D) WIND SPEED; 110 MPH EXP C H i EEo 11 U ........... Summit Structural Design Project: Flaherty Trellis Engineer: RKB Design of : Gravity Load's Gravity Loads: Trellis Slope= 0 to 12 Trellis Dead Load Framing 9,0 psf Misc. 1.0 psf Total (sloped) 10.0 psf Total (horiz) 10.0 psf Summit Structural Design Project: Flaherty Trellis Engineer. RKB Design of: Seismic Mass and Seismic Loud Development Roof Area (ft2) Weight (lbs) 319 3190 Height (ft) Length (ft) Weight (lbs) Walls(ext) 9 0 0 Walls(int) 0 Total 3190 Roof Area (ft?) Ultimate Working Stress 319 857 612 Roof Trib Line Shear (Ibs) Wall Line I Area (ft 2) Working Str( All �T 319 61.2 Shear (lbs) rho Total 1.30 796 feet- 1000SI who meters 500 MUSGS Design Maps Summary Report User—Specified Input Building Cade Reference Document 2012/2015 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 39.81)N, 1.21.880W Site Soil Classification Site Class D - "Stiff Sail" Risk Category I/II/III USGS-Provided Output Ss » 0.617 g Shfs - 0.806 g Ss = 0,537 g S1 = 0.276 g SM1 = 0.51.0 g Spi = 0.340 g For information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEFIRV building code reference document. MCE;t Response Spectrum 0.90 0.21 0.72 0.54 L7.�1 0,35- 0,27 ,30,27 0.1^a u.09 0.00 0,20 0.40 O.GG 0.00 1,00 1.20 1.40 i.GO 1,80 «,00 Period, T (sec) [design Response Spectrum 0:54 0.4$ 0.4« Cn 0.24 0.7.3 0.12 0,06 0.00 0.00 0,20 0.40 O.GO 0.00 1,00 1,20 1.40 1:60 1.20 2.00 Period, T (sec) Although this information is a product of the u,S. C:c,oingicai Survey, wr provir to, no warranty, naprC.ssCd or irraplictJ, ar, to the ae�;uracy of the data Contained therein. ;rhis toot is not a substitute for technical subject-rnatte'�r knowledge. Summit Structural Design Project: Flaherty Trellis Engineer: RKB Design of: Seismic Load Development (ASCE 7-10) Level ROOF story Ht. (ft) 9 Seismic Design Category D Ss 0.617 Mapped 0.2 sec spectral response Occupancy 2 S1 0,276 Mapped 1 sec spectral response I 1 Site Class D • In accordance with Ch 20. TL 16 Sms 0.806 Site Coef, T 11:4-1 0 0 Sm1 0;51 Site Coef, T 11.4-2 0,0 1 SDS 0.54 Design Spectral Response (0.2 Sec) 0 0 SDI 0.34 Design Spectral Response (1.0 Sec) _ra--._,_._ _......- - 0.0 1 System Tim-__-_ _...._._._. j Timber Frames '0 0 R 2 Omega 2 Cd 2 Ht Limit 35 Cs 0.27 12.8-2 Max Cs 1.64 Min Cs 0.02 (Al outside of SJ) Ct 0.02 x 0,75 0.00 0,0 Ta 0.10 Cu 1,4 Max T 0.15 No limit for drift 0 0 Use i 0.10 Alt Ss 0,617 Ss may be 1.5 if 5 stories and regular 0.0 0,0 V= 0.269 *W Height to Roof (hn) = 9 ft V' 0.9 k Vert Dist Exp. (k) 1 Level ROOF story Ht. (ft) 9 hi (ft) 9 1 wi (kips) 3,2 (wi*hi) (kip -ft) 29 Gvx 1.00 Veq (kips) 0.86 5 VEQ (kips) Diaph. (kips) 1 1 30th 0 0 0 0 0.00 0.0 1 6th 0 0 0 0 0.00 0,0 1 5th 0 0 0 0 0.00 0.0 1 4th 0 '0 0 0 0.00 0.0 1 3rd 0 0 0 0 0.00 0,0 1 2nd 1st 0 0 0 0 0 0 0 0 0.00 0.00 0.0 0,0 1 1 PROJECT: a SUMMIT STRUCTURAL DESIGN PAGE: ENGINEER: www.summitchico.com DATE. �yE DESIGN OF PROJECT. PAGE: SUMMIT STRUCTURAL DESIGN ENGINEER: www.summitchico.com DATE; DESIGN OF ro °C .> ¢ f 7{ � - -- __ _ ____ __ _ ------ COMPANY --- COMPANY PROJECT Summit Structural DesEon Nov. 22.201614.38 WoodWorks' sorru+,txtrrorr µ'boo rusic:e Knee Brace Column Design Check Calculation Sheet Woodworks Sizer 10.1 Loads: Loa:.i Tys7 Distribution. Piet- Location ('ci Magnitude Shea: tern Start End Start Cnd 3Frrditlr, (., LGa'dl 'aad Axaial 1536 (nce.. = 0.00^) N80 los Load2 ind Axial `t63 :cc 0..0011.) %3 i lb^, t,o !33 W' na,' !%c:fit G55 _ . �iC' 1207 lhs t11F '...1: al Ax?al belti9l ng}. Eq.3,fl-3. 5-t ilJ$ I Lateral Reactions (lbs): 8' W �t 01 a I I Iac.tored: �� eflt j77 i Fa cor o: 226 Timber -soft, D Fir -L, No.1, 6x6 (5-1/2"x5112") Support. Nornwocd; Bearing length = column width Total length. 8'; Pinned base: Load face = width(b); Service: wet; Ke x Lb: 1.0x 8.0 = 8.0 [ft); Ke x Ld. 1.0 x 8.0 = 8.0 [fl); Lateral support: top = Lb, bottom - Lb, f Analysis vs. Allowable Stress (Dsi) and Deflectinn linl Cr f. GSI P`I s- r7t`s.1 C171 Va]: UC: :ina1 E7.5/neSJ 4EI Shea: fv/bv' 57.11 3Frrditlr, (., to 533 Fb' 1536 ''b1 Fb' _ 0 as Axial EC - 31Fc' a `t63 tic/Fc' - 0 6 r.x al Bea rir:g fe = 31 c^-�. ,.. G55 fc./Fc, _ 0:05 i le.i 'Odd belti9l ng}. Eq.3,fl-3. 0 37 .'s:l 7�:1 +:?g.1.CS:i. c! •v � :'n .�. 'S <.I./994 •. 1.l1rC0 0.11 I at:ei ur£;' Additional Data rC'^Cx F/li P CG r; Cr CL/CP CF Cfu Cc' .Prt "I .,cii Nv' t0 :,60 JO i ui - - - 1..0C, 0..$0 2. 120;' 1.60 1C� 1.00 i,t€0 3.0007.04 0 60 2 e0c, 90 0.9! l PO i;.85 00, .. - ,.Oil 0.9E ;..... s:.. si0 '1.9E 0.91 CRITICAL LOAD COMBINATIQNS. n arh2 ,ir'+.6W, L' 49$, V design ptis jbr; Fiend regi Lr' i1 - .6D+.6Y; R; - 1245 lbs Ic ;ref lcafiio;:: LC d2 .6:)e,6'rl (1±ve) LC: ;12 - .6D,, ..6W (total;. y,1 1, LC. Ii 1, - Cs only, P 937 lbs ir epi i;!` 1 ;i+.6 Il - fc/F'cF:.) _ 0.t?6• 1-11rh6c;t Lr�rooi- live Lv=concentrated B=-eerthg4a 4e i.^ the A:,al/si 011,. Put ASCE 7.-10 / 1h 2412 CALCULATIONS ^crClUCt. l tla: ET 22 ,a,I( lb-ic2 ,iv,a cP. _..eor. - L+e 'Onion Erofn all rron-dead loads dive, wind, 51eow...) !'lection - 2,00(1)eats Load Deflection) +Uve Load Deflecc.ion. Design Notes: 1.:NoodWorks analysis and design aro in accordance with the [CC International Building Code (IBC 2012), the National Design Specification (NDS 2017.),. and NDS.Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 1s 'yp COMPANY Summit Structural Design PROJECT Location c) Xaynitude- anit i'362 aezriny.: Nov 22, 2016 14:33 stent Erld S*wart: Enid. Wo r k s .rt3,?:. leau, "w"vrirrh�` SOrnttNTMOR WOOD M$1C.R '4linimi,m hParihn Main Beam .v. Design Check Calculation Sheet �+ind AloodWorks Sizer 10.1 Loads.: C, 10 - (,;,.0 'yp ::;t.ri.t,u�lion Pa::._.. Location c) Xaynitude- anit i'362 aezriny.: Cern stent Erld S*wart: Enid. 1.06 .rt3,?:. leau, rti Area' ' '4linimi,m hParihn 10 JJ .v. i.oati2 �+ind FUIi eArl-,a Cie°1'n C, 10 - 16.0tJ t5. 5 IaSf -oaci.3 Wi"'d I?oint +1),.33 � 1.34 1207 its.<, Se tc ..night Dead :.a?3 t)ili: 19.6 plf� �Maxiirnufn'R�,acdons (lbs) and Bearing Lengths (in) ; 20,_2 1,. Inte:eaori>ci: <:�au PaCtared: i ?oto: i'362 aezriny.: V V Len7th 1.06 in re L_ C16 ' '4linimi,m hParihn innnlh enitinn ,.ce.l- 4••F... ......J .............. .v. Timber -soft, D.Fir-L, No. 1, 6x16 (5.1/2"x15") Supports: All - Timber -soft Beam, D Fir -L No.2 Total length 20'-21'; Service: wet: Lateral support; top= at supports, bottom= at supports: Analvsis vs. Allowable Stress lnsil nnei naflontinn tint ten. I Additional Data: F'ACTM3: F/c. (.p:xit C.;y 'Ct:' rt CL t;:F C1 Cr Cf: rt Ci Cn LCo S.00 1.00 - - - - 1.017 0.60 .,GCI 3 la'• 3.. .; i.50 Ji; s..0 ti.9 0.969 L 00 1.0) 1.100 0.67 j.Go .i If ;o .t I ' 1 70p Er,ii.n .):. SA till. 1. !ori 1.0t} 'i .00 CRITICAL LOAD COMBINATIONS' il ? - u7, y > l9'ro7 r S'7 r: ... 1.192 1 b u.fl I i s - Lr 8; vt^ total}. dt-tai I t.e'. ;, ,<s� Qinlpact 7.r•. oat` ' ive' Lc*-coneeitrated E>earthquak.e li red lle tmalysls output. ASCas 7-113 . 15C 2012 CALCULATIONS: 74.'75e.6.6 2b-i.n2 tefty.ct. i,on Coflac;:ian from all non -dead loads (live, wind, snow...) ..tai be .le;ccinn - 2.(;0(Dead Load Deflection) '+- Live Load Deflection. Design Notes: 1, WoodWorks analysis and design aro in accordance with the IGC International Building Code (18C 2012), the National Design Specification (NOS 2012), and NOS Design Supplement 2. Please verify that the default deflection limits are appropriate for your application. 3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4. i. V V 1551. fh/i:b' 0:26 1�'e F.Q t%Eft' I,:.12 m ilcl99 Cie°1'n C, 10 - <.L/994 Q. 6'7 = L/360 0.15 t-ecl`r, +1),.33 � :.d726 1.00 L/?.40 0.33 Additional Data: F'ACTM3: F/c. (.p:xit C.;y 'Ct:' rt CL t;:F C1 Cr Cf: rt Ci Cn LCo S.00 1.00 - - - - 1.017 0.60 .,GCI 3 la'• 3.. .; i.50 Ji; s..0 ti.9 0.969 L 00 1.0) 1.100 0.67 j.Go .i If ;o .t I ' 1 70p Er,ii.n .):. SA till. 1. !ori 1.0t} 'i .00 CRITICAL LOAD COMBINATIONS' il ? - u7, y > l9'ro7 r S'7 r: ... 1.192 1 b u.fl I i s - Lr 8; vt^ total}. dt-tai I t.e'. ;, ,<s� Qinlpact 7.r•. oat` ' ive' Lc*-coneeitrated E>earthquak.e li red lle tmalysls output. ASCas 7-113 . 15C 2012 CALCULATIONS: 74.'75e.6.6 2b-i.n2 tefty.ct. i,on Coflac;:ian from all non -dead loads (live, wind, snow...) ..tai be .le;ccinn - 2.(;0(Dead Load Deflection) '+- Live Load Deflection. Design Notes: 1, WoodWorks analysis and design aro in accordance with the IGC International Building Code (18C 2012), the National Design Specification (NOS 2012), and NOS Design Supplement 2. Please verify that the default deflection limits are appropriate for your application. 3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4. i. COMPANY PROJECT Summit Structural Design Nov. 22,2016 1 ®R 4:34 WoodWo V r C k I s Secondary Beam SOF71VARf, FOR 1 00 ) DkS GN Design Check Calculation Sheet WoodWorks Sizef 10,1 I Loads I Ype I15t 4butip 1' Pat- L, '11fie !!11� r, i6 Z"', ',art F'116 2'33 ad r ea Le r+yl e"qt h, 2 p s f v a Ft 1, Ar Ps 1 LID:, Maximum Reactions (lbs) and Bearing Lengths (in) : 6-2" - On i act:or ed Idf. i6 2'33 Le r+yl e"qt h, 1 C'r X5111 r eq A Timber -soft, D.Fir-L, No. 1, W (5-1/2"x7-1/4") Supports: All -Timber-soft Beam, D.Fir-L No.2 Total length: 6'-2.0"; Service: we[, Lateral support: top= at supports, bottom= at supports. Analysis vs. Allowable Stress (psi) and Deflection (in)—iri. Nns ?ni? - v Fb f ii F 'n Q r, ii'd Do 199 vc? 1 n r„ 0. 2') L13v81J, 0 Additional Data; AC TORSI z -/E ,:ps! i criCm Cc C, CIF CfU Cr Cfrt "I, LCA Ise' I_;0 �.. .an 11.00 1 .00 00 0 k10 1.100 1 }:i"'+1200 0.00 1.00 of.) Icon con I.) F 625 OD 0 3 .00 - c'.5 . r, m � 11 i on 00 ;.00- 'o 0 3 CRITICAL LOAD COMBINATION$: shear I LC 111 D 0'11 Y, V - !.39, V design m 117 lbs B e n di _g I z LC I D on 1 y, M .2352 1 bs',-ft De " I ocr ion LC, i li 6t�, * 6. ve) I,C 3 D 6W, to I jj I to 3 -snow I1' =ii'qvact Lr�roo? live Lr -concentrated 5tnearthcuake 1 n al V!3 S 0' 1,;_7 S �,�ry t e I, thk� A 7-0, / ?Bf' 2012 CALCUI-ATIONS ve "lent n 0II f, oil non -dead load� (live, wind,s row_ "ot—, bfflec"'.I111 2.J­Duad 'W.a,�' Tgivf.4 Design Notes: 1 Woodwork$ analysis and design are in accordance with the ICC International Building Code (IBC 2012), the National Design Specification (NDS 2012), and NDS Design Supplorneni, 2. Please verify that the default deflection limits are appropriate for your application. 3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.0.1. Project: Flaherty Trellis Engineer: RI<B Design of: Spread f=oundations Mid Footing W+= 440 lbs. W-= -440 lbs. S= 0 lbs. D= 2500 lbs. b= 2,25 ft. Side dimensions of square footing d= 1.00 ft. Depth of embedment h= 3.3 ft. Height of applied load above grade. P= 340 lbs, Applied load. Allow. Bearing= 1500 psf Ultimate Uplift Resistance 'T„ = 2c(D -1)(B L) + y(D -1)2(2518 + L - t3)K„ ton Allow. Lat. Bearing= 200 pcf Allow. Uplift Allowable Uplift Resistance T,, = T,,11.5 Resistance Ta= 0 lbs Where: Overturning/Uplift Check: c =130 psf D = footing depth (ft) Righting M MT Mr= 2233 Ib ft 0 ` 25 deg (assumed • conservative) L = footing length (ft) Y = 1.10 pcf B = footing width (ft) OTMMo= 1940 Ib -ft st=1+(0.10)DIB K„=1 -sin 0 Mo/Mr= 0.87 Status OK Overturning Bearing Check: Max Bearing M= 1445 lb -ft Bearing Check: Pmax= 3699 lbs 1492 psf Max Down Load= 2940 lbs. A= 5.463 ft2 Bearing Capacity= 7594 lbs. S= 1,898 ft' Status OK Status OK