HomeMy WebLinkAboutB17-0001 000-000-000m Mo Residential Fire Sprinkler - System Component List ALARM. BEI L. PERMIT# BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR CODE COMPLI)W.CE DATE 2.22 l7 BY BUTTE COUNTY BUILDING DIVISION APPROvm O� GOMP,�Y �A0 * C-16 CALIFORNIA LI ENSE NO 305 �Lz-. 80f7 • RESIDENTIAL FIRE SPRINKLER 4 ,' SYSTEM DESIGN BY FOX COMPANY, C--16. LIC. # 305365 - 'PER REQUIREMENTS OF NFPA 13D, 2013 EDITION DWAYNE WICK WILK GUEST HOME ' 3578 CHICQ ST. 3578 CHICO ST. CHICO CA. 95928 CHICO PLAN NUMBER 1456 12/26/16 WATER SOURCE IS�WELL & HOLDING TANK WATER PRESSURE AT HOLDING TANK 50 'DEDUCT PRESSURE LOSS FROM SOURCE TO SPRINKLER CONTROL VALVE MAIN SECTION EQUIV.FT. 1--1/2'PIPE = 100 FT. 1 GATE VALVE = 2 FT.. 1. CHECK VALVE 6 FT. 3 90 ELBOWS = 21 FT.. 5 COUPLINGS 5 FT. I TEES (RUN) - I FT. 0 TEES (BRANCH) = 0 FT. TOTALS - .135 FT. X .0178 - 2.4.0 47.60 DEDUCT HEAD LOSS FOR.ELEVATION ( 15 FT. X 0.434 ) - 6.51 J 41,.09 DEDUCT PRESSURE LOSS FOR PIPING FROM CONTROL_ VALVE TO FARTHEST SPRINKLER PIPE SECTION ONE EQUIV:FT. 1" PIPE _ 90 FT.. 6 90 ELBOWS - 30 FT. 0 CROSSES = 0 FT . 3 TEE(RUN) & 45 ELL._ 3. FT. 2 TEES (BRANCH) = 10 FT. TOTALS = 133 FT.. X. •.1067 -14.19 26,.90 BRAND'OF HEADS = GLOBE 4906 G.P.M. - P.S.I. CONVERSION FORMULA: K FACTOR OF HEADS USED = 4.9 (G.P.M./ K FACTOR)2 = P.S.I. EQUIVALENT FEET CALCULATED @ 2 HEAD 2 HEAD = 26 G.P.M. FLOW ( 13 G.P.M. EA.) FRICTION LOSS `C' FACTOR = .150 MINIMUM PRESSURE REQ'D. FOR SPRINKLER HEAD(S) = 7.04 P.S.I. DOMESTIC LOAD OF.S G.P.M. 1..5 IN. PIPE = 100 FT. @ 5 -G. P.M. = 0.08 P.S.I. TOTAL PRESSURE REQ D. = 7.12 P.S.I-. PRESSURE AVAILABLE IN SYSTEM = 26.90 P.S.Z. 3995 Olive Highway Oroville;.CA 95966 Phone (530) 533-2730 "ow THL S7=RXNKLER* SYST�/�f t7��RAT�S .UTILITY DISTRICT WATER SUPPLY: The .a.yztem activatez the 4tne zpninkten.d wheneven: A) The FLOW SWITCH zen.dez water 6tow in the .dy.btem e.Lthen by a head '4i4ing' o44, on the INSPECTOR TEST.VALVE being opened to z4mutate a head 6Zn..ng o4-4. The zyztem can be SHUT DOWN by .tunntng OFF the CONTROL VALVE at the bate o the FIRE RISER. Durr,' \1NLV0 5WAit-. Sd;ZrrW T -R& - �rtT��2G 1�rA'Pri2 ��Lr'3�►i�vrksr{ S�tSTE^'�. Zc9i3 C 9c 5Ec-. 2 31-5.3.3,2 TEST & FLUSH SYSTEM: The 4nzpec.to4 .teat valve zhoutd be opened .MONTHLY to te.e.t and -6tu,6h the .ey.etem, activate atanm belt and zmok.e atanmz. A two . to three minute water 4tow ,tee t zhoutd be zu44icZent .to te.6t a.et. openation.a o4 the .6y.4tem. "THE INCH"" RESIDENTIAL AUTOMATIC SPRINKLERS MODEL GL4906 ONE INCH ADJUSTABLE FLAT PLATE CONCEALED PENDENT DESCRIPTION AND OPERATION The Globe Model GL4906 Residential One Inch Adjustable Concealed Pendent Sprinkler has a flat plate profile that utilizes a 3mm frangible glass ampule as the thermosensitive element. It features economy, aesthetics and the lowest allowable water flow with a nominal 1"of adjustment for easier installation. The combination of the 3mm frangible glass ampule and specially designed deflector make the Model GL4906 the ultimate in life safety and fire control. It has met the strict requirements of. Underwriters Laboratories Inc. as described in UL Standard, 1626, for Residential Sprinklers for Fire Protection Service, and should be used accordingly. This sprinkler should also be installed in accordance with the appropriate NFPA Standard 13, 13D or 13R and under the direction of the approving authoritieshaving jurisdiction. All that is seen at the ceiling is.the 3 5/16" diameter flat ceiling plate color finished to match the specifier's exact requirements. The ceiling plate is soldered to the sprinkler's special uppersupport assembly in three places. Upon the application of sufficient heat, the plate falls to the floor exposing the residential pendent spray sprinkler. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass bulb to shatter. This results in water discharge which is distributed in an approved pattern. TECHNICAL DATA • See reverse side for Approvals and Specifications. • Temperature Rating: 155°F (68°C) • Water Working Pressure Rating: 175 psi (12 Bars) • Factory. tested hydrostatically to 500 psi (34 Bars) • Maximum lowtemperature glass bulb rating: -67°F (-55°C) • Frame - bronze • Deflector - brass • Screw - brass • Bulb seat - copper • Spring - nickel alloy • Seal - teflon • Bulb - glass with alcohol based solution, 3mm size • Cover Plate - brass Upper Escutcheon Assembly - steel RESIDENTIAL FLAT PLATE CONCEALED PENDENT • SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER BULB COLOR N.F.P.A. MAXIMUM TEMPERATURES CEILING TEMPERATURE ORDINARY 6' 68°C RED qp" 38a 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 • FAX 989-846-9231 SEPTEMBER 2011 A-10 BULLETIN GL4906, REV. 41 RES1bkNI TIAL AUTOMATIC SPRINKLERS MODEL GL4906 ONE INCH ADJUSTABLE FLAT PLATE CONCEALED PENDENT SPECIFICATIONS AND APPROVALS SIN NOMINAL GL4906 12'x 12' 13 G.P.M. - 7 P.S.I. 14'x 14' 13 G.P.M. - 7 P.S.I. 155°F (68°C) 18'x 18' 17 G.P.M. - 12 P.S.I. MODEL "K" FACTOR THREAD SIZE LENGTH FINISHES SPRINKLER WITH cULus 135°F 57°C PLATE Blight Chrome White Painted GL4906 4.9 (68 metric) 1/2" NPT 3" (7.6 cm) Bright Brass* X X Satin Chrome* Other Painted Finishes* NOTE: METRIC'CONVERSIONS ARE APPROXIMATE. *FINISHES AVAILABLE ON SPECIAL ORDER. FOR PAINTED PLATES OTHER THAN WHITE, CONTACT GLOBE FOR ORDERING SPECIFICATIONS. INSTALLATION DATA FOR FLAT AND SLOPED CEILINGS** 'ONE INCH ADJUSTABLE FLAT PLATE CONCEALED PENDENT MODEL MAXIMUM AREA OF MINIMUM WATER DISCHARGE & COVERAGE PRESSURES NEEDED PER SPRINKLER* GL4906 12'x 12' 13 G.P.M. - 7 P.S.I. 14'x 14' 13 G.P.M. - 7 P.S.I. 16' X 16' 13 G.P.M. - 7 P.S.I. 18'x 18' 17 G.P.M. - 12 P.S.I. 20' x 20' 20 G. P. M: - 16.7 P.S.1. NOTE: MINIMUM .9' SPRINKLER SPACING. :WHEN THESE SPRINKLERS ARE USED IN NFPA 13 SYSTEMS, A 0.1 DESIGN DENSITY MINIMUM SHALL BE UTILIZED. *REFER TO PAGE 2 OF THE GLOBE RESIDENTIAL SPRINKLER INSTALLATION GUIDE FOR NFPA 13D and 13R REQUIREMENTS. ORDERING INFORMATION CROSS SECTION FLAT PLATE CONCEALED PENDENT FIR��RRI�BI(aER�itllil�Tl��i SEPTEMBER2011 SPECIFY • Quantity • Model Number Style • Orifice • Temperature • Finishes desired • Quantity - Concealed Wrenches - P/N 332765 • Quantity - Protective Caps - P/N 332868 COVER PLATE SIZE WHITE 135°F PART # CHROME 135°F PART # 3 5/16" 332892 332891 GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manu- factured products found to be defective in material or workmanship for a period of one year from date of ship- ment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AlRPAR K DRIVE, STAN DISH, MICHIGAN 48658 989-846-4583 1-800-248-0278 PRINTED U.S.A. FAX 989-846-9231 www.globespdnkler.com BULLETIN GL4906, REV.#1 F Bronze Sp"ring Loaded .Check Valve 3/8"-2" Figure No.:36001. w/TefloniDisc: " :FigureN0* .' 3600SJ :w/Teflon Disc " Figure.M. 3615 W-buna-N O1sc F1gure..No.-3615SJ •w/Bt na-N'Disc. 125 PSI Saturated Steam, :with. TFE-Disc : Buna-N Disc Rated �at 250 PSI f. ' 250 PSI,Non-Shook"Cold.Water,'.Oil; or.Gas,Fluid:Pressure;`.Non-Shock W.O.G: •i •�+ ��. 9 ' A 6 e` », O 3. 8 S{w figure No .3600 Igur6 No ;3615 Figure No 3600$) �) t r :Threaded: Figure NM.3615SJf 1 'Copper to'Copper Grinnell check.vaives may be- installedir vertical lines with,.- upward ith.upward flow or in anyintermediate posltlon., Do Not Use For Reciprocating Air Compressor Service. r.: Do Not;Use _as'a'Footvalve _y Y. •!� ! �. a ,'.:'D ."•ate. _ y —tet + y�'{ '�,{`{ .-7. 4'•.�.i c... ti 'IhG L1\T ' •� -PM,���i�?r"' �v �vbi8c'`,� ; `�✓�. ka o�E ✓a Y �3."p .#Jft ,!.�`—`•^'�.n t.r+' �y rs i - _ ` I)t.! ,.`y'f'+.��'o- �y. •J.�;•�J 1..\ � ` * Ditnenslohs—.Weights f ` ii 1 1'::jY.1Cv .cG• — r :y.r.;ir ofi1 - . Nominal Size Part . : Specglcation . 1. Body •Bronze. ASTM B•584 Alloy.C84400 .• .. . 2. Stem Stainless Steel ASTM . A-582 Alloy -S30300 3. Spring 316 Stainless Steel 4. Disc Holder Stainless Steel Type 301 . S. Disc Teton, Fig.3600 5A. Disc Buna-N, Fig. 3615 6. Seat Ring _ Teflon 7. Seat Screw Stainless Steel ASTM A-276 Alloy S43000 8. Body. End Bronze ASTM B•584 Alloy C84400 Nominal Size DIM ensionsgNpprox. Fig. 3600 FIg�prox3600SJ A B .., C 31s .2 P/e ' '171s' .4 .4'. '/s 21/it 13/e '13/16 4.. _. A 3/4 21l4' .1518 15/16 :.5 1 25/e • 2 1'/s 215/,8 23/a 111l16 1.2 1.3 1'12 .35/1s 23/4 .2 1.6. 1.9 2 3314' 33/e 25116 2.4 27 aA��o �n4,do 1 800 854-1015 t 5RE'SSURE G FIRE l INKL t p U.S. GUAiGA AMETEK • Use on wet or dry sprinkler systems! ` • SOIld brass backed! • 114 A .NTP -LM brass fitting; 3'/2 diameter 300 lb./sq. In. Capacity ,164D„16 7,V,esys7M.4s AUGES 100 2Q0. 1S �tl 225 so. 2so 2s . 27s goo .. .- . � @LISTED r APPROVEC 1T r ER''.BPO _~ 208f6;&IgRqsd-*_P�O.',Box 28480 Potter Electric Signal &. M1j. L! St. _----MID 01464161 4) 878432VV(8q0)-325-3936-` ' ad shamel finish IH *crows -,,.Ci6htkt Flat at: I 25P250 VAC 16.0 Anva ;ix Ampd at 6-30 VD0 Noto:'B paddles.fits furnished with each unit.one for each plpo* 'environments - Mae so: NO"..'1609680 FP .:,National FlisWarm Code 'bTH 'PAT sprinkle The vine must not rub thMnalde of TEE or bind In oily way. T1.16 6-rdlow detector on large systems The deviCs CA so tile If! is led oK a or apts an adlUitt - Ab - pnetirnatic retard. Th6 switch6i are' ictus"ted when i 116W Of ope min. . oxist'lor a period of. Ilms',nocaMary to.overoolffle -the JNjPECTli0N AND TESTING:.0hock oparation o ."umillby'oponing. condition must the draln DNA" poctor'i test vaiv On horizontal they should be Initalled on the top side of the PIP@ If there are no p CAsions jor W PIP e. pipe . where they WRI be accesalble.. The unit& should not be Imitill6d y�llhlm 86. thaV8R-SF1s not reeornmerid6b0f device on the system.'OpplION of a valve, draln or fhthg which changes of unit has aYNPT bushing for threadIng into a noh-corrosl�s TEE, 960 Fig. n its jawlated protective and test 2 for proper TEE size, type and Installation. Ths*' nay of.ths,Imspection and g monitoring system should W In &00"noe, device Into the TEE . f1ttingasahowni . nFIg.2 . . Carom . at tie taken Codes and Standards andtor authority having jur*ftO*n ("minufacturor scrowthe to property Ment the davics for the direction of watorflow. r9oommisinds q-tiartarly.or more fr.q�uintM. �ifth­'_ ch unit. These paddles liave raised ieftering that shows the pipe CAUTION: There are 9 paddles lumished ea size and type of TEE that they are to be used Wlth.".The proper paddle MLLat be used. The screw that holds the paddle Must.be securely tightened. 8 PAGE I CW 2 )�orr�rz BELLS PBA -AC & PBD -SIZE VOLTAGE-- Potter Electric Signal Company Potter Electric Signa & Mfg. LTP;, i'r �--, CURRENT 2081. Craig Rd.R.O.- Box 28480 1967 Leslie Street .4. MINIMUM FT. A St. Louis, MO. 631416. Don Mills, Ontario, Canada M3B2'M"3:, 12VDC (314)878-4321 / (800),325-39,36. (416)441-1833 .1 2A 85 UL LISTED,A "'APPROVED'. 75 8 Sizes -Available:. ,:6", 8", and 10" 12VDC P.BD1128­, -Voltages Available: ;24VAC .12A 90 120VAC' 75 10 .,12VDC(10.2to.15.6)Polarized 12VDC PBD`1210.'�-- .24VDC (20.4.to'312) PolarizedIt I I 92 7.. 75:1 6 'Service Use:, _,Tird Alarm 24VDC PBD246 General Signaling .06A 'Burglar Alarm __75 8 24VDC PBD248 -Environment:. Indoor or Outdoor Use (See Note 1) .06A 91 -400 to 1500F(outdoor use require, 79 10 eatherproof, W backb6k)'.. 24VDC PB02410 Termination: 4.. Not: -1 &AWG'strinded wires,,.-,-:, .06A 94 _Flnlih:�.`Red -powder,coating'... -79 61 !,�.','El ELL`,SHOWN ...^-..,.Optional:;ModelBBK 1-.,weatherijroof;backb6x 24VAC PBA246 1806024 .17A 91 75:'. Thesewibrating.type'bdII6,are...degighedrJor.,use-* as: fire,,.burglar,4r°gen6ral. signalin g,;di6�jjhey have!low.00wer�a 24VAC consumption,and high decibel rathas he:Unitm6unts.br astandard.*4"square-electrical 66kforjndoor.use-,or on a model .17A -BBK-1,,,weat p ba"ckbo)(for outdoor.*apf)licAtions.,.*..- her'roof. 75 10 24VAC ALNSIENT...,PROl'E6�-i6N'-�-�';!*,-'�';'.����:-�",-",,"-----,.I LIDC.BELLS,.ARE"POLARIZEDAND BUILT-IN .-.'TRA 04 -SIZE VOLTAGE-- MODEL*�'INO'�",-,,! "STOCK NO. �--, CURRENT .T-YO16AL- 0 10 Fr.0,110 .4. MINIMUM FT. A 6 12VDC PBD126' 1706012 .1 2A 85 75 8 12VDC P.BD1128­, 1708012 .12A 90 75 10 12VDC PBD`1210.'�-- 1710012 12A 92 7.. 75:1 6 f 24VDC PBD246 1706024. .06A __75 8 24VDC PBD248 1708024 .06A 91 79 10 24VDC PB02410 1710024 .06A 94 -79 24VAC PBA246 1806024 .17A 91 75:'. 24VAC PBA248 1808024. .17A =94 75 10 24VAC PBA2410 .17A 04 6 120VAC PBA1206 1806120 .05A 92 82, 8 120VAC PBA1208 1808120 .05A 99 82_-- 10 120VAC PBA12010 1810120 .05A 7-T 99 85 Weatherproof backbox model BBK-1 Stk. No: 1500001." - 'Notes: 1. Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Liboratories as specified in UL Standard 464. UL temperature range is -30* to 150°F. 2. Typical dB ratings are calculated from measurements made with a-convenlional sound level meter and are indicative of output levels in -an actual Installation. PRINTED IN USA MKT. #8850001- REV K PAGE I OF 2 MFG. #5400776 - 4/94 9600 KLINGERMAN STREET * P.O. BOX 3365 SOUTH EL MONTE, CA 91733 * USA O TEL: 626.444.0541 * FAX: 626.444.3887 E-MAIL: info@afcon.org * www.afcon.org C US CPUC - STEEL - COPPER a.#510 #511 #514 0 o 10 Patented 0 Installation Instructions Install on .CPN'C pipe as a hanger and/or restrainer per their engineering sheets. Some are additionally listed for use for use with steel and copper: pipe. #510 & #514 install on top, bottom or side of beam. =x #511 install on top or bottom of beam. #513 install on top or side of beam. #515 & 519 install on side of beam. Required fasteners furnished: -#904 for #515 c.P.%.c. Max. Hanger #905 for #510 thru #514 Pipe Size. • Spacing 3/1 — -- — 5 1/2 1 ------------- 6 1 1/4 -- — 6 1/2 1 1/2 — — - 7 Z----------- 8' 2 1/2 ------------ 9 3 -------------- 10