Loading...
HomeMy WebLinkAboutB17-0003 030-461-011BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES INSPECTION CARD MUST BE ON JOB SITE 24 Hour Inspection Line (IVR) :•530.538.4365 (Cut off time for inspections is 2pm) Development Services cannot guarantee inspections on the date requested Office: 530.538.7601 Fax:530.538.7785 www.ButteCounty.net/dds Permit No: B17-0003 Issued:.1/3/201.7 APN: 030-461-011 Address: 2068 TEHAMA AVE, OROVILLE Owner: OWEN TANYA Permit Type: SOLAR ROOF -RES Description: Roof mount, 5.8 kw; 21 modules; 1 solar edge �l AREA Flood Zone: None SRA Area: No Front: Centerline of Road: Rear: ti SRA: Street: AQ . Interior Total Setback from Centerline of Road: ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING Inspection Tyve IVR INSP DATE Setbacks 131 Foundations / Footings 111 Pier/Column Footings 122 Eufer Ground 216 MasolU Grout 120 p bT4 . i v7 Do Not Pour Concrete Until Above are Signed Pre -Slab 124 Gas Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing 149 Underfloor Ducts 319 . Shear Transfer 136 Under Floor Plumbing 412 Under Slab .Plumbing " . 411 Do Not Install Floor Sheathing or Slab Until Above Signed Shearwall/B.W.P.-Interior 134-' Shearwall/B.W.P.-Exterior Roof Nail/Drag Trusses 129 Do Not Install Siding/Stucco or Roofing Until Above Signed Rough Framing 153 Rough Plumbing 406 Rough Mechanical . .316 ' Rough Electrical 208 4 -Way Rough Framing 128 Gas Piping House 403 . Gas Test House 404 Shower Pan/Tub Test 408 Do Not Insulate Until Above Signed Permit Final .802 Electrical Final 803 • ZAC742 Mechanical Final 809 Plumbing Final 813 Fire S rinkler Test or Final 702 Inspection Type IVR INSP DATE T -Bar Ceiling 145 Stucco Lath 142 ' OFFICE COPY Setbac .... 517-Ot.,J3. Pool Pi . Bldg Permit: Gas Tf . Address: Pre -Gu' Pre -De Pool F.GAS By: l r t 'Date: - - Pre -Pia i �• Date: j Electric By: - - - �..a,miacturea-nomes Setbacks 131' Blockin nde inin 612 Tiedown/Soft Set System 611 Permanent Foundation S stem 613 Underground Electric 218 Sewer 407 Underground Water 41.7 Manometer Test 605 Continuity Test 602 Skirtin Steps/Landings 610 Coach Info Manufactures Name: . Date of Manufacture: Model Name/Number: Serial Numbers: . Length x Width: Insi nia: Public Works Final 538.7681 . Fire De artment/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final y "PROJECT FINAL T�71. *Project Final is a Certificate of Occupancy for (Residential Only) PERMITS BECOME NULL AND VOID 1 YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A 1 YEAR RENEWAL 30 DAYS PRIOR TO EXPIRATION 4"_ OTOVO LTAIC SYSTE M. - PV SYSTEM SUMMARY: CITY NOTES: i SITE LOCATION: ROOF MOUNT RESIDENTIAL PHOTOVOLTAIC SYSTEM THIS PROJECT COMPLIES WITH7HE FOLLOWING: 2013 CALIFORNIA BUILDING CODE (CBC) ":Z"'� i 2013 INTERNATIONAL BUILDING CODE IBCA -'�' SYSTEM SIZE (DC) STC: 21 X 280 = 5880W DC (IBC) , ,. _ r...t-•..� s-.�::��, {� . • - 2013 CALIFORNIA ELECTRICAL (,',ODE (CEC) r � � Yf + PTC: 21 X 257.00 = 5397.00W DC 2013 NATIONAL ELECTRICAL CGDE (NEC) �'> c- 1�'i �'"s,-e` nrJ�y. tr i a2;Y.r ♦ j.. s{,xy„„„`.. 0 2013 CALIFORNIA FIRE CODE (Cf -C) �• SYSTEM SIZE (AC) 21 X 257.00 X 98 /o = 5289.06W AC AS ADOPTED BY CITY OF OROV,!LLE eRlataufl dlle0��A'�`>x ;r� P 9 MODULES 21 X HANWA Q -CELL. Q PLUS -G4 280, 280W MODULES ALL SOLAR ENERGY SYSTEM i'_QUIPMENT SHALL BE SCREENED TO THE-�•�s�e� �, INVERTER 1 X SOLAR EDGE SE5000A-US INVERTER MAXIMUM EXTENT'POSSIBLE E\ND SHALL BE PAINTED A COLOR SIMILAR •'� {� ZA6S Taha a A' u, TO THE SURFACE UPON WHICi-i THEY ARE MOUNTED ROOF COMPOSITION SHINGLE: e �'�,,, S Tehame Ave F,k 91 j VISIBLE PORTIONS OF THE SOLAR PANEL SUPPORT STRUCTURE AND ANY EXPOSED �t � � 4. . r9'r} TILT 4 & 18° PITCH ELECTRICAL CONDUITS, BOXES AND PANELS WILL NOT BE EXPOSED, AND WILL BE COLORED MATCHED TO EXISTING ROOF OR SURROUNDING HOME.' AZIMUTH 90° 2" X 4" RAFTERS 24" O.0 f * - Poplar Avenue RAFTER/TRUSS SIZE @ MODULES SHALL BE TESTED , LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN t ' i 5 Elementar7 School.y ACCORDANCE WITH UL 1703. Tk FIRE CLASSIFICATION SHALL COMPLY WITH TABLE , ,�� v :.. .� �, 4 ATTACHMENT TYPE QUICK MOUNT WITH IRONRIDGE RAIL 4 1505.10F THE CALIFORNIA BUILDING CODE BASED ON THE TYPE OF CONSTRUCTION OF .„ NEW 225 AMPS MSP WITH 125 AMPS MAIN THE BUILDING. CRC SECTION 8,902.4 + �:. '�} `�• 4 -t ��- a# t M +fi MAIN SERVICE PANEL • ~ waa BREAKER ON BOTTOM FEED SMOKE AND CARBON,MONOX6E ALARMS ARE REQUIRED PER CRC SECTION R314 ANDr..- 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD. INTERCONNECTION TIED TO PV BREAKER IN MSP . SITE LOCATION OCPD RATING 30 AMPS 1 STRING WITH 11 MODULES AND 1 STRING WITH RESIDENTIAL BUILDING UNDEF`ROUND ADDITION OR IMPROVEMENTS SHALL REPLACE STRINGING NON-COMPLIANT PLUMBING FLXa:URES WITH WATER CONSERVING PLUMBING FIXTURES IN 10 MODULES IN SERIES IN EACH STRING ACCORDANCE WITH CGBS�j HOUSE AERIAL VIEW: UTILITY SOUTHERN CALIFORNIA EDISON (SCE) SECTION301.1.1 AND CIVIL CODE ! 101.1 AS FOLLOWS: ' -WATER CLOSETS: 1.6 GPF, (GPF GALLONS PER FLUSH) -FAUCETS (ALL INTERIOR) 2.2 (M1GPM = GALLIONS PER MINUTE) -URINALS 1.0 GPF �s -SHOWER HEADS 2 5 GPM TABLE OF CONTENTS PV -1 SITE LOCATION AND HOUSE AERIAL VIEW PV -2 SITE PLAN PV -2A ROOF PLAN WITH MODULES LAYOUT PV -3 ELECTRICAL LINE DIAGRAM PV -4 ROOF MOUNTING DETAILS, ELEC. CALCULATION, ELEC. ELEVATION & MATERIAL LIST PV -5 LABELS PV -6 DATA SHEET: MODULE PV -7 DATA SHEET: - INVERTER PV -7A DATA SHEET: - RAIL INSTALLATION NOTES: .;Y THE PV BREAKER SHALL NOT EXCEED 120% OF THE ALLOWABLE BACK FEED OF THE MAIN SERVICE BUSS RATING. PV WIRE SHALL BE USED ON DC`RUNS FOR UNGROUNDED/TRANSFORMERLESS e INVERTERS. INSTALL•CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUITS ARE ATTACHED •r0 THE ROOF USING PRESSURE TREATED WOOD IN CASE Int' OF COMPOSITE ROOF OR COUNDUIT HANGERS IN CASE OF CONCRETE ROOF ... MODULE LOCATION i r CLIENT: REVISIONS: DATE: TITLE: SHEET: C-10 982892 DESCRIPTION DATE REVISION 12/07/2016 a�. FreedomScalor SCOTT�RONNIE & TANYA 2068 TEHAMA AVE, DESIGN SITE LOCATION AND Freedom Solar Co . OROVILLE, CA 95965 d BY: GREG HOUSE AERIAL VIEW PV -1 (530)-370 9175 JOB 25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 a r NO.: FS -12-029 Tel: (951) 321-0855' '•t • _ y, PROPERTY LINE ' °320'-10" i , ROOF LINE r , - ..1 �z N 2 HANWA Q -CELL'. Q , "a r :•.. �_, 4, - , �, , ^ . ; " `,_PLUS - 4 2 280W MODULES '' • - G 80, t• _ ,r,. .•*� -�• Y.. +.y _ ,. - - - I r•" , ,, -'� - t'. -;r't h'�„ T a .,, /,, - •' .y.. n - .. r• _.. , - .•c • ' r. .. c �, -, - . '.r 4 . elf 231-10" '. {::. a „ r ^ ` T + r + �... +i� G' ['' i " „ .• r . n5 CT 4 i ' -re .n n. .:r _ DRIVE 10" WAY y - 72•x„ 69'-4" 75'-3" „1 • e DRIVE • _ ; ' ,, y . ' WAY .. (N) MAIN SERVICE PANEL i r . + TE HAMA AVE SITE `PLAN ♦' r x ' * y +'� t •:.' 1 . " . M t * + SCALE: 1/64" _ V-0" + Ir ei^^^���^^��"^ CLIENT: REVISIONS: DATE: TITLE: SHEET: - C-10 982892^ RONN I E & TANYA 12/07/2016 " DESCRIPTION DATE REVISION Freedoms®tare, SCOTT DESIGN BY: GREG ,, TE HAMA AVE, < SITE PLAN _ 4_ r .• • ` Fr@@007Solar CO F •. f ROVILLE, CA 95965, !"T , .PV-2 }, _ jos ' 25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 •° (530)-370 9175 t ` ' No . FS -42-029 Tel: (951) 321-0855 _ yy T ROOF AREA STATEMENT ROOF MODULES QTY PITCH AZIMTUH ROOF AREA ARRAY AREA 1 21 18°/4° 90' 862.51 SQ FT 385.70 SQ FT NOTE: EMT CONDUIT SUPPORTED BY PIPE HANGERS 12" TO 18° -AWAY FROM ROOF EDGE ATTACH CLAMP AT 25% FROM EDGE AND t 2" X 4" RAFTERS.) 24" O.C. (TYP.) 50% FROM CENTER OF MODULES ' Q3 JUNCTION BOX MOUNTED TO THE RAIL 17'-8 4 DEGREE PITCH ARRAY �- (N) 21 HANWA Q -CELL. Q PLUS -G4 280, 280W MODULES (N) ATTACHMENT POINTS Q @ 72" O.C. MAX. LEGEND: ® CHIMNEY O PIPE VENT ' MSP AC INV 4'-8" (N) JUNCTION BOXQ3 (N) MAIN SERVICE PANEL (N) AC DISCONNECT (N) 3/4" EMT CONDUIT RUN 2" THE ROOF SURFACE ROOF PLAN WITH MODULES LAYOUT ABOVE SCALE: 1/8" = 1'-0" (N) SOLAR EDGE SE5000A-US INVERTER eiaadw comma° w CLIENT: REVISIONS: DATE_" 12/07/2016 TITLE: SHEET: Freedom Solar c-10 982892 SCOTT RON N I E & TANYA. .a - DESCRIPTION DATE REVISION 2068 TEHAMA AVE, DESIGN BY: ROOF PLAN WITH \ , Freedom Solar CO OROVILLE, CA 95965 GREG MODULES LAYOUT P �/ —2A I (530)-370 9175 JOB 25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 NO.: FS -12-029 Tel: (951) 321-0855 Max. UIL,ru: (225A Bue) * (1.2) = 270A Max Rating (120% of Bus) PV Backfeed (30A) + Main Breaker (125A) = (155A!5 225A) See 690.64 (B) (2) of 2013 CEC__ _ _ _ STRING -1 11 HANWA Q -CELL. Q PLUS -G4 280, 28OW MODULES SOLAREDGE P300 I , POWER OPTIMIZERS I � STRING -2 10 HANWA Q -CELL. Q PLUS -G4 280, 280W MODULES I I I JUNCTION 4 - #10 AWG, THWN-2 1 - #10 EGC, THWN-2 IN 3/4" EMT CONDUIT INVERTER SOLAREDGE SE5000A --US F�� AC DCS\ AC`Calculations k System AC Wiring , Pmax = (257 PTC Rating) * (21 Panels)* (98% Inv. eff) = 5289.06Wac (N) 225A M - Imp = (5289,06Wac)'/ (240Vac) AIN 22:03A- - -- • - - -- SERVICE MAIN Inverter Maximum Output Current = 22.03A 125A / 2P ^ - A -design = (22.03A) * (1.25) = 27.54A MAIN BREAKER — BOX I I I �– – ---- j SOLAREDGE P300 I _ POWER OPTIMIZERS I y I I 3 - #10 AWG, THWN-2 — L-------------------------1 1 -#8 GEC, THWN-2 IN 3/4" EMT CONDUIT . General.Notes 1. (21)„HANWA Q -CELL. Q PLUS -G4 280, 280W MODULES wired and listed to UL1703 standards t 2. SOLAR EDGE SE5000A-US Inverter with integrated DC Disconnect and Arc Fault Protection. Attached with system electrical specifications and ground fault protected & listed to UL1741 standards. 3. Photovoltaic system ground will be tied into existing ground at main service from DC Disconnect/Inverter as per NEC Sec. 250.166(B). "The Grounding Electrode Conductor shall not be smaller than the largest conductor supplied by the system and not smaller than #6AWG.” 4. Equipment operating 150 volts or greater shall only be serviced or replaced by qualified personnel. Field protection may be in the form of conduit, closed cabinet or an enclosure which requires use of tools to open. 5. Solar Photovoltaic System equipment will be installed in accordance with requirements of Art. 690 of the 2013 CEC. 6.Minimum height of conduit above roof to match temperature derating factor. 7.Photovoltaic DC conductors entering the building shall be installed in metallic raceway and shall be identified every 10 feet -- and within 1 foot above and below penetrations of roof/ceiling'assemblies, walls, or barriers – with minimum 318 -inch -high white lettering on red background reading:"WARNING: PHOTOVOLTAIC POWER SOURCE" E�ucac" Com "aa nw: CLIENT: Freedom Sola r C-10 982892 Freedom Solar Co 25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 Tel: (951) 321-0855 SCOTT RONNIE & TANYA , 2068 TEHAMA AVE, OROVILLE, CA 95965 , (530)-370 9175 TO OTHER LOADS 30A / 2P ' 30A, AC PV BREAKER DISCONNECT i dI/ o " '– – – – – – – – – – L---------------- - CONNECT TO EXISTING UFER 8. System Grounding Electrode conductor for PV system to be sized to meet the requirements of both 250.66 (AC) and 250.66 (DC), 690.47(C) not smaller than # 6 CU AWG. 9. If the existing main service panel does not' have a ground rod or Lifer, it is the pv contractors responsibility install one. 10. Smoke alarms and carbon monoxide detectors will meet the necessary requirements per CRC R314, R315 11. UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM. 12.Terminals of the disconnecting means may be energized in the open position. 13. A signage labeled "SOLAR LOADS ONLY" is to be installed on dedicated solar sub panel to be used for PV only. REVISIONS: DESCRIPTION DATE REVISION DATE: 12/07/2016 DESIGN BY: GREG JOB NO.: FS -12-029 TITLE: ELECTRICAL LINE DIAGRAM UTILITY METER SHEET: PV -3 Photovoltaic Panel Mounting Detail Scale: NTS ELECTRICAL :CALCULATIONS BACKFEED BREAKER SIZING MAX. CONTINUOS OUTPUT 21A @ 240V 21.0 X 1.25 = 26.,25 AMPS 30A BREAKER - OK NEC 690.64(6X2) 225 X 1.20 = 270 270 - 125 = 145A ALLOWABLE BACKFEED DE -RATED AMPACITY OF 8AWG CONDUCTOR @ 0.87 TEMPERATURE CORRECTION 40 X 0.87 = 34.8 AMPS - OK TO UTILITY POLE MAIN SERVICE 6" PANEL TO ARRAY JUNCTION BOX IN ARRAY MOUNT INVERTER SOLAREDGE 5000 -US UM ■�1 AC DISCONNECT J r-- FLOOR ELECTRICAL EQUIP. ELEVATION �1 SCALE: NTS � MATERIAL LIST QTY EQUIPMENT DESCRIPTION lidl� ✓1 �1 C-10 982892 - : Freedom Solar . - -- - - Freedom Solar Co 25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 Tel: (951) 321-0855 CLIENT: SCOTT RONNIE & TANYA 2068 TEHAMA AVE, r- TOROVILLE, CA 95965 (530)-370 9175 OPEN CIRCUIT VOLTAGE (Voc) : 39.16V DATE: HANWA Q -CELL. MAX. POWER VOLTAGE (Vmp) : 31.16V 21 Q PLUS -G4 280, SHORT CIRCUIT CURRENT (Isc) : 9.55A DESIGN BY: 28OW MODULES MAX. POWER CURRENT (imp): 8.99A SOB NO.: PTC RATING: 257V R EDGE SOLAR MAX. DC INPUT VOLTAGE: 350V MAX. AC OUTPUT VOLTAGE RANGE: 211-240V 1 WITH MAX. AC OUTPUT CURRENT: 21A POWER MAX. AC POWER OUPUT : 5450W' OPTIMIZER CEC EFFICIENCY: 98% 1 JUNCTION BOX 600VDC, NEMA 4X, UL LISTED 1 AC DISCONNECT 600VAC, 30A, NEMA 3R, UL LISTED V 1 PV BREAKER 2 POLE, 240V, 30A 32 ATTACHMENTS QUICK MOUNT E -MOUNT ATTACHMENTS 117'• RAIL IRONRIDGE i 36 MID CLAMPS IRONRIDGE END CLAMPS 12 END CLAMIPS IRONRIDGE GROUNDING MID CLAMPS 40' CONDUIT 3/4" EMT CONDUIT lidl� ✓1 �1 C-10 982892 - : Freedom Solar . - -- - - Freedom Solar Co 25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 Tel: (951) 321-0855 CLIENT: SCOTT RONNIE & TANYA 2068 TEHAMA AVE, r- TOROVILLE, CA 95965 (530)-370 9175 REVISIONS: DATE: 12/07/2016 TITLE: _ - - - --- - ---- ROOF MOUNTING DEGTAILS, ELEC. CALCULATION, ELEC. ELEVATION & MATERIAL LIST SHEET:} - ^` ,� DESCRIPTION DATE REVISION DESIGN BY: GREG SOB NO.: FS -12-029 LABELS: LABELS SPECIFICATION: 1. ALL CAPITAL LETTERS 2. MINIMUM 3/8° LETTER HEIGHT 3. ARIAL OR SIMILAR, NON -BOLD 4. WHITE LETTERING IN RED BACKGROUND 5. WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT ` (DURABLE ADHESIVE MATERIALS MUST MEET THIS REQUIREMENT 6. ALL SIGNS SHOULD BE REFLECTIVE CAUTION: POWER TO THIS BUILDING IS ALSO 0 WARNINGSUPPLIED FROM THE FOLLOWING I SOURCES WITH DISCONNECTS TURN OFF PHOTOVOLTAIC LOCATED AS SHOWN AC DISCONNECT PRIOR TO WOWING INOIDE PANEL (N) 21 HANWA Q -CELL. Q PLUS -G4 1280, 28OW MODULES (N) MAIN SERVICE PANEL (N) AC DISCONNECT - (N) JUNCTION BOX (N) INVERTER SOLAR EDGE 5000A -US TEHAMA AVE. i 11 . t DISCONNECTION MEANS; TO BE INSTALLED AT ALL AC AND DC I DISCONNECTS RESPECTIVELY PER NEC 2011 690.14(C)(2) AC DISCONNECT PHOTOVOLTAIC DISCONNECT FOR UTILITY OPERATION INVERTER OUTPUT CONNECTION TO BE INSTALLED AT MAIN SERVICE PANEL PER NEC 2011 705.12 (D)(7) MARKING SHOULD BE PLACED ON ALL INTERIOR AND EXTERIOR PV CONDUIT, RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES, EVERY 10 FEET, AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS ANDALLPV COMBINER AND I INICTION BOXES, WARNING PHOTOVOLTIC POWER SOURCE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION; TO BE INSTALLED AT DISCONNECTING MEANS PER NEC 2011 690.17 ' WARNING ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION. PHOTOVOLTAIC POWER SOURCE SHALL BE LABELED WITH THE FOLLOWING WARNING AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT, AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS,MAY BE EXPOSED DURING SERVICE PER' NEC690.35(F) - DIRECT-CURRENT PHOTOVOLTAIC POWER SOURCE TO BE INSTALLED AT INVERTER PER NEC 690.53 OPERATING CURRENT: 17.9A OPERATING VOLTAGE: 350.00V SHORT-CIRCUIT CURRENT: 23.62A MAX SYSTEM VOLTAGE: 500.00V AC DISCONNECT PHOTOVOLTIC DISCONNECT FOR UTILITY OPERATION WARNING _ ELECTRIC SHOCK HAZARD CONTACT QUALIFIED SERVICE PERSONNEL FOR ASSISTANCE Nominal Voltage 240 Volts Nominal AC Frequency 60 Hz Maximum AC Power 5880 Watts Maximum AC Current 26.25 Amps Max.Overcurrent Device 30 Amps Max. Current per Pole 26.25 Amps z 0 1 (1 CLIENT: rDESCRIPTION DATE: TITLE: SHEET: PIN. C-10 982892 DATE REVISION Freedom Sol®r _ _SCOTT RO N N I E & TANYA , • :12/07/2016 2068 TEHAMA AVE, _ - DESIGN - LABELS. Freedom Solar CO OROVILLE, CA 95965 BY: GREG PV -5 25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 (530)-370 9175 JOB NO.: FS -12-029 Tel: (951) 321-0855 The new high-performance module Q.PLUS-G4 Is the Ideal solution for all applications thanks to Its Innovative cell technology UNTUM. The world -record cell design was developed to achieve the bast per- formance under real conditions -- even with low radiation Intensity and on clear, hot summer days. Q.ANTUM TECHNOLODYi LOW LEVELIZED COST OF ELECTRICITY Higher yield par surface area and lower BOB costs and higher power 'classes and an efficiency rate of up to 17,1 %. NFA INNOVATIVE ALL-WEATHER TECHNOLOGY I/ Optimal yields, whatever the weather with excellent low-IIght and temperaturo behaviour, ENDURING HIGH PERFORMANCE -r Long-term ylold security with Anti -PID Technology', - • Nal. 144*Spot Protect and Traceable Quality Tra,QTm, UGIIT-WEIGHT QUAUTY FRAME _ High-tech aluminium alloy frome, certified for high snow (6400 Pa) and wind lads (4000 Pal MAXIMUM COST REDUCTIONS Up to 10 % lower logistics costs due to higher module capacity per box. SAFE ELECTRONICS' ` Protection against short circuits and thermally Induced power losses duo to broathabiD junction box and welded cables, A RELIABLE INVESTMENT Incluslvo 12-yoar product warranty and 26 -year linear performance warranty'. r THE IDEAL SOLIrf10N FOR1 rnWenMl dldtlllhge mrnmaclal/IrMustrlN buildings E=ngineered in Germany ` I>�CCLIi Neu INnI TO►i�AN6;N 2015 �.�u,r a cavi• I ., APT last dendltlorm, Calla nt •1000Y at oUnt gruundud, wldl conducitre metal foil cmolod Modulo eurlace, 25-C, 168h r Bao data shoat an rear ror further lalramatlan. O CE LLS Eiaea�icaah�aarNo: CLIENT:: C-10 982892 Fre.edormSolar SCOTT RONNIE & TANYA , ' - 2068 TEHAMA AVE, 1. ` Freedom Solar Co OROVILLE, CA 95965, 25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 (530)-370 9175 , Tel: (951) 321-0855 „ Fomat 65.7Ina 39:4 in k 1.26 in (induding,Rame) e9O«° >noo-i _ _ _ _•. (1670 mm x 1000, mm x:32 mm)' - .. welg(d 41.451b(I&8 kg) T �......r aromwaa Front Corm 0.13in (3;2 " thermally pre•stres* glass with anli-refleM_ion ter6rolcgy BadcC9vui Composite (dm�� _...___.._+• o- Faae elack anodised aluminum -- t ♦ .nam«, can 6 x 10 G.ANTUM dark sola cells Junglon,bm 4.33.in x-4.63 in x 0,9 in (110 mm x 115 mm x 23 mm), ` Protection class IP67, with_bypass'dicd¢s __ . '...aw,n,-a.•eio4', i CaOEa 4nWSO&cable;(+)=39,37in(1000mn).(-)x39.37in(1000MN �L L- Connector.- Tyca Sotarlok PV4 VIP68' POWERCLASS .. :41: 2'270 �r•- ,=.. ..275( v 1B0 MINIMUM PERFORMANCE AT.STANDARDTESTING CONDITIONS, STC! (POWER TOLERANCE 4.5W/ -.OW) hereratM"I _ ,P,ae� 11111 ` 270_275 280 Streit Circdl CLTMO* - T I,. [AI 9:43 9.49 _ 9.55. ..Opine t2rcdrvdnge�._..,..vK.....�!--^-•`-.- .83.65...._...__...- '38.90 ......_.39:16 Cur til at MPP• I- , [A] 8.84 8.91 _ 8.99 j.VdtagbalMPP' V,e,- IYI _ 30.53 30.85 31.16 1%1 216.17 - �a 4 x16.47 216.77 MINIMUM PERFORMANCE At NORMAL OPERATING CONDITIONS, NOc' PoyretatMPPI �^ -_ PeIVA -- 4 200.2 203,9 _^ 207.6 Shed CNcdr Llrreal• - - - ~ lu NAI 7.60 T 7.65 7.70 00 Clm* voltage' V - IVI M 3&06 y 36.30 - 35.55 !".3 (MPP ' Aon' IAL_ 6.93 6:99 7:05 _ ....�.�,� V,,, - tv) �. 28.89 ^�-.. 29.17 ~ y 29.45 ,'100D 1wrN, 25'C, spcceum AM.IAG 'Mearrm,ent mlaanw sTC,a%, NOC aS%'E00 tMhN, NOCT„wtttrvn AM I50 'e/91wlraMt., acWdrauanmydiner ^OCELLSPERFORM- MANCE WARRAN W. '`� `J RERFORMANCEAPtOW IRRADIANCE>1 - . 79D M� emu. A[Win 97% of narinarpmer dunrrg tirstyear. Thereafter max. 0.6%d go- w , a- dation-per year: ,1 A,1 (east 92%ol�MminCl pvker-afmr 10"S. } Al mast 839(; al nominal paaereirer E° T 25, ears. - C a---r--r-r---r--r- r -i --i-- i '0 Ap darn-wilhin'memwernenrt prances, vtarramies in aooadance ai lh the- • v.arrenb te_nies or ice O CELLS safes WAW01 &.4:11 a --- -- - '-- -- . organtsalronolyour respeclbecon". a n a n The Weal charge rnmoduleefficiency atanimidiance at 200 Wfmain relation r.a..00a.w -nus to]000 WAn2(Dolh at25°C end..AAt 1.5Ospeclrnmi)is •1,5%(relali,e). il"TEMPERATUI :rarxpaaera CoeNlaen aria a [%/IO . 40.04 Teyaatae.CoaBkidnl of Ve. J p I%7N1 T peuWreCpeNldenldP- _ V - [%/10 _ -0.40 Ni)rialDpgallgOellTe�eiaure� �NOCr_- vn - 11335:4(45 :3'`C) f Ma)Ilsl®Slugs vdnP.,Y;n IVI_ 3000(IEC)(4000(UL)_ SidetyCla3x II M a ue Suter Fuse Fnthq - - IA OC)_ _ 20 Rro intloy� ~ . _ - .. �_.. ^ Y C / TYPE l _ CdaxLoaGNLI __ �IIIISMI 75(3600Pa) Petntbed bdutatanpemUo--401Fupto+1851F ~` Os emus tol6 ditty (-401C-up to +85°C) (pad''1rallrgCU01 11"] _ T 55.6 (2666 Pi)' �Isee, installation manual UL 1703; y0E orality TesteQ CE•oomp0anl; Kaaba d Modeles pis 41161 - 32 IEC612IS(Ed.2):IEC61730(Ed.I)applxadonctmA -_'- • ` . KUNbU of Was P09 S3 Coaalaar 32 i [♦ ° Kaaba or Pallas pa 40 Gort7leer 26. OVE `PaUel Oesenstorl5 CL x.W z N) 8 6 7 ul x 45.1 m x 46 1m us o„w (1745x1145x.11_70_mm), i Palle Walgbe ..._ 1435 111( Vkg) j AVE Inswilaiton instructions mutt be rollw•ed. See the installation and operating marwal ar contacl our technical. SPlYCe 6eparimenl fa Iurther iMormnbn on appraed Instailallan arw use oflhis DioCucl. _ - NemrhaaCEl15USA corp. . ' • 3,00 Speebun.Cantet DOW. Supe 1250. "1", CA92618, USA I TEL +1 949 748 69 961 EMAIL l Wle wM.acells,ia REVISIONS: DATE: DESCRIPTION DATE REVISION 12/07/2016 DESIGN BY: GREG JOB NO.: FS -12-029 TITLE: - SHEET: DATA SHEET: MODULE . PV -6 u. R t .z j ) I11 - u ri • 'Y Eiaea�icaah�aarNo: CLIENT:: C-10 982892 Fre.edormSolar SCOTT RONNIE & TANYA , ' - 2068 TEHAMA AVE, 1. ` Freedom Solar Co OROVILLE, CA 95965, 25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 (530)-370 9175 , Tel: (951) 321-0855 „ Fomat 65.7Ina 39:4 in k 1.26 in (induding,Rame) e9O«° >noo-i _ _ _ _•. (1670 mm x 1000, mm x:32 mm)' - .. welg(d 41.451b(I&8 kg) T �......r aromwaa Front Corm 0.13in (3;2 " thermally pre•stres* glass with anli-refleM_ion ter6rolcgy BadcC9vui Composite (dm�� _...___.._+• o- Faae elack anodised aluminum -- t ♦ .nam«, can 6 x 10 G.ANTUM dark sola cells Junglon,bm 4.33.in x-4.63 in x 0,9 in (110 mm x 115 mm x 23 mm), ` Protection class IP67, with_bypass'dicd¢s __ . '...aw,n,-a.•eio4', i CaOEa 4nWSO&cable;(+)=39,37in(1000mn).(-)x39.37in(1000MN �L L- Connector.- Tyca Sotarlok PV4 VIP68' POWERCLASS .. :41: 2'270 �r•- ,=.. ..275( v 1B0 MINIMUM PERFORMANCE AT.STANDARDTESTING CONDITIONS, STC! (POWER TOLERANCE 4.5W/ -.OW) hereratM"I _ ,P,ae� 11111 ` 270_275 280 Streit Circdl CLTMO* - T I,. [AI 9:43 9.49 _ 9.55. ..Opine t2rcdrvdnge�._..,..vK.....�!--^-•`-.- .83.65...._...__...- '38.90 ......_.39:16 Cur til at MPP• I- , [A] 8.84 8.91 _ 8.99 j.VdtagbalMPP' V,e,- IYI _ 30.53 30.85 31.16 1%1 216.17 - �a 4 x16.47 216.77 MINIMUM PERFORMANCE At NORMAL OPERATING CONDITIONS, NOc' PoyretatMPPI �^ -_ PeIVA -- 4 200.2 203,9 _^ 207.6 Shed CNcdr Llrreal• - - - ~ lu NAI 7.60 T 7.65 7.70 00 Clm* voltage' V - IVI M 3&06 y 36.30 - 35.55 !".3 (MPP ' Aon' IAL_ 6.93 6:99 7:05 _ ....�.�,� V,,, - tv) �. 28.89 ^�-.. 29.17 ~ y 29.45 ,'100D 1wrN, 25'C, spcceum AM.IAG 'Mearrm,ent mlaanw sTC,a%, NOC aS%'E00 tMhN, NOCT„wtttrvn AM I50 'e/91wlraMt., acWdrauanmydiner ^OCELLSPERFORM- MANCE WARRAN W. '`� `J RERFORMANCEAPtOW IRRADIANCE>1 - . 79D M� emu. A[Win 97% of narinarpmer dunrrg tirstyear. Thereafter max. 0.6%d go- w , a- dation-per year: ,1 A,1 (east 92%ol�MminCl pvker-afmr 10"S. } Al mast 839(; al nominal paaereirer E° T 25, ears. - C a---r--r-r---r--r- r -i --i-- i '0 Ap darn-wilhin'memwernenrt prances, vtarramies in aooadance ai lh the- • v.arrenb te_nies or ice O CELLS safes WAW01 &.4:11 a --- -- - '-- -- . organtsalronolyour respeclbecon". a n a n The Weal charge rnmoduleefficiency atanimidiance at 200 Wfmain relation r.a..00a.w -nus to]000 WAn2(Dolh at25°C end..AAt 1.5Ospeclrnmi)is •1,5%(relali,e). il"TEMPERATUI :rarxpaaera CoeNlaen aria a [%/IO . 40.04 Teyaatae.CoaBkidnl of Ve. J p I%7N1 T peuWreCpeNldenldP- _ V - [%/10 _ -0.40 Ni)rialDpgallgOellTe�eiaure� �NOCr_- vn - 11335:4(45 :3'`C) f Ma)Ilsl®Slugs vdnP.,Y;n IVI_ 3000(IEC)(4000(UL)_ SidetyCla3x II M a ue Suter Fuse Fnthq - - IA OC)_ _ 20 Rro intloy� ~ . _ - .. �_.. ^ Y C / TYPE l _ CdaxLoaGNLI __ �IIIISMI 75(3600Pa) Petntbed bdutatanpemUo--401Fupto+1851F ~` Os emus tol6 ditty (-401C-up to +85°C) (pad''1rallrgCU01 11"] _ T 55.6 (2666 Pi)' �Isee, installation manual UL 1703; y0E orality TesteQ CE•oomp0anl; Kaaba d Modeles pis 41161 - 32 IEC612IS(Ed.2):IEC61730(Ed.I)applxadonctmA -_'- • ` . KUNbU of Was P09 S3 Coaalaar 32 i [♦ ° Kaaba or Pallas pa 40 Gort7leer 26. OVE `PaUel Oesenstorl5 CL x.W z N) 8 6 7 ul x 45.1 m x 46 1m us o„w (1745x1145x.11_70_mm), i Palle Walgbe ..._ 1435 111( Vkg) j AVE Inswilaiton instructions mutt be rollw•ed. See the installation and operating marwal ar contacl our technical. SPlYCe 6eparimenl fa Iurther iMormnbn on appraed Instailallan arw use oflhis DioCucl. _ - NemrhaaCEl15USA corp. . ' • 3,00 Speebun.Cantet DOW. Supe 1250. "1", CA92618, USA I TEL +1 949 748 69 961 EMAIL l Wle wM.acells,ia REVISIONS: DATE: DESCRIPTION DATE REVISION 12/07/2016 DESIGN BY: GREG JOB NO.: FS -12-029 TITLE: - SHEET: DATA SHEET: MODULE . PV -6 I - • Power OptlmkerSped/kation-P300/P350/P400/P40S SOIaP' • • Power Optimizer Specifications - P300 / P350 ! P400 / P405 Single Phase InVerters for North America l T . P40S . . F- s O a r s ; SE9000A-US / SE380OA-US / SE5000A-US / SE6000A•US! 8 , SE760DA•US / SE10000A-US / SE1140OA-US Rated Input DC Powel'1 - 100 JSD 400 S110 MA -LIS 3E1E06A US I 3E9000A US-5E8000A US. iE7800A-US SE10O00A U3 3E114OOA-US w Absolute Maximum Input Voltage (Vac) 'OUTPUT 125 - u 1� NominalACPowerOutput $000 3800 5000 6000 7600 �9QQ0Q��4 V 11400 . ............... .............. VA .......... Maximum Soon Circuit Current (Ise) of connected PV Modute ......................................... Max, AC Power Output ...• ............... ...... 1111 ...... 5400 ® 208V 1OB00 ® 208V 9900 4L0 6000 .8390 12... ............ .............. . 49AR°jARY, ,.....,,.,,.,.. Jl49AA��4AY, 1111, VA Maxlmum OC Input Currer4 AC Output Vakage Mln: Nom,-Max.nl . % Maximum Efficiency 183-1D8-229Vae................................... 1111. 1111 ............:. .......................... ...........,.. ,.............,.. ...........,. .. ........ Weighed Efficiency ................... AC Output Voltage Min_:Nom:Ma)Lfu r ✓ Ovorvoltago Category 111 •340.284 Vac _ ..............I....... 1111 .59.3,.6080.5.,...,....... .........., ............... ;OUTP.UT.Ot1RING OPERATION:(POWER'OP,TIMIZER'CONNECTED TO`.OPERATING tNVEfiTER)�c-=•,; ,••�,.,,ti .�}F,-.-,+r•••4,�.:L•h,,,�•u••:•:e•+.:;•.•.' ACFree)uenelrMln:,NornMou.!:L.... ............. .:��.... 15 May. ContlnuausOutPutCurrant y. Co O 12,5.,, 16 1 Z9 pZ(BV .. 4f1®298V „�.5,,,., bi.G� �4QY., 1. 23 I, 32 4tZ1�.i44.... I. .. ,q 60 ... . „ 1us �Foi Tnrasnotd L ..... ..:.A . gip' r ..... ....... .....1 Utill Mgnitorin � Idancin Pratacdart ..........111.. 1111 ....... ................. ................. ........... CountryCondi rablaThroaholds yea yon FINPUT STANDARD COMPLIANCE; _,ft , 1 • �:a�: - _ . 1 .. Maximum DC Power(STC� ......................_,.................. 4050 .. p100 8740 8100 .,30250 _ .13500 1S3S0 1111 1111.. FCC Part15 Class B, IE1:6100118.2, IECBt0011-G•J Tronsform8r•14sat Unsrounderl ....,,,,., .,.,.........,.,, 1111... ...,,...., ,.,.....,..,.,. ......... .... ....... fig..,, ;..:. ...l IEC82.0&r(etaas n safely), UU7at . •...:.:....... ........... 1111 1111, ., Mi1x.InputVolto�P. ........ 1.111. .. ..... ........ �, ...... .................... . ..... . .. 1111. ......,. ... 1111... .. ..1111. � .. .Vdc UL -99 (5 -VA), UV Resistant Noln. Dt] Input VoltoBe ' 323 208V 17 0 ®240V 111159,.. RoHS _ 1'bs ................ Max. InputCurrenNn ...... 33®208V. 94.8.,.., ....9.5.... ,I. ,,..i�..,.'18.4 208V L.....Is I, ....... �..AQ•s ?.aa4x. l., Adc,.. - • ••? Max:)nputShonGrcuitCurcant ........,,,,.,.., Adc ......... 1000 .................•.... Revone PolaNty Protection .. , .. 1111.,. 1111 11...... 1..,. .......,...,........, ............... 1111 .. . ............. ............................... .....1111.. .........,,.... ........... ........ 147 %214 x 40.5 7 5.55 z 9114 x 1.59 GrOUfld-FBUIt Isolation DOtaation 600ke sanalBwK,.,...,......,•,...,,.,,,..:,.•.,,...,,.,,.,,.,. 1111,., ,,...... , ......... .. ,,,,>, MRlllmumlrtvarterEff.Gency ;-, .............. ...........1111 1111, ... . - 97,7 98.1. f�... 98.3 9A.3 B8 98 08 %?1111 MCA / 7yoa I Amprgrwl CEC Weighted Effldancy - 97.9 98, J 97 ®208V 97 ®IOBY ��.1 , I 97 5 97,5 .P � 24q/.. 97,5 1111 .. : % Double insulated; Ampherol ................................... . .. NightdrinsPoworConiumption .. 2.5 c 4 - !N_ 0.95 i J.0 1.2119 "AODITIONAL FEATURES - m 'It Operating Temperature Range SUPp91tOd CORIIflUn)P.etlOfl lntOff5C08 ., ........1111 ............... .... d5485t 85232/ Etho�nQty LBBoo.(.OQdeR91� ................. ,.,,.,.,,, .......... PrIXed'gn Rating Soilorfte PopwerOptimIzers 1 e ..1..111, ........ Relative Htonidty ' ,,,, Rapid shutdown -NEC 2014690.12 Yes % f _ r47 __ T SafetT UL3741L U11699Br Ul19Sg t CSA 22,2 ............... ................. Orld Connection Stendolds,.,,..,., 1111, .................... ....IEEElir.4. ..1....111,.,.. ........,....... ...., ......, ......... .................. Emissions .. FCC HFUS class 0 INSTALLATION SPECIFICATIONS •=« - '_= r� .=au '.' _ �a ..- " _ '^. ' �.�' - y , .- ACeutQutgendulttliu/AWG,W,•m,n.1 ul 11"AWG • -. •. •,.••. ,, ,3�4 minlmum�9-3 AWG ........ 1111.. . ,.....,,,. :1111.. DC input conduit size / d of stringa% minimum / 1•I 3/4° minimum / 1.9 strings 3/4' strings / 18.6 AWG hyv,gA ep•............................. ............... ............... ................ .. ..................................1111 .. gWSa..g�,...... Dimensions with Safety Switch 305 x 12.5 x 7.2 / 77S x 919 x 184 90. x x . . lit - A�!><)Yn41., ... ............•. ........77AAAMr,;9. .... Qxy) 7:...•........., welfjht with SofeEy,SwlttN. ,91 .Z / 29:2. .54;7;% 24:?. 40,1.....,.. . ............ .. ' .Ib (kg_, .. Natural convection Cooling Natuml Convection and Intornal Forts (usar roplaccablo) fan (year ...................... [9p.1R544I11P). ........ ........... .... 11:11... 1111 1111 . ...............:......:................................ ... ......... Nolle2.3 ..,,.,....,.,,. 1111.., < g0.,.,. ....,..,,. ,. ., dBA... ......................................... ............... .............� Mln-Max, Operating Temperature 13 to +140 / -25 to +60 140 to ♦60 verslen evallableni) 'F /'C Mw ................. ................. ..... .......... ...... ......... ........... ..:.......:............................... ......... .............. ..... ... ....... ProteeNonRodnE...•....................................................................k...... ,..,.,,...,.,,. 14PoratlllrMdonxl 10011413 014010 W1019t S01901104UPP 6 bauw8EWX4d 70WWIfrwnitsnSE7600A•US0a2NNFd). In Rino�iiue grade itimler Ppl SWONNR2 Imi - 0l-0avanlon P/N19P.uaA•U7aO6NNW(for 76WW menor9f9000MU99aINNU1). - _ M., sunsPEc • s Power OptlmkerSped/kation-P300/P350/P400/P40S SOIaP' • • Power Optimizer Specifications - P300 / P350 ! P400 / P405 i, T . P40S . . F- [r 8 , Sj - ,f Rated Input DC Powel'1 - 100 JSD 400 415 w Absolute Maximum Input Voltage (Vac) a 125 Vdc u 1� 8-48 8-80 12.5-106 Vdc Maximum Soon Circuit Current (Ise) of connected PV Modute 10 .y Aae Maxlmum OC Input Currer4 •i . % Maximum Efficiency 99.5 i Weighed Efficiency "•8 Ovorvoltago Category II ;OUTP.UT.Ot1RING OPERATION:(POWER'OP,TIMIZER'CONNECTED TO`.OPERATING tNVEfiTER)�c-=•,; ,••�,.,,ti .�}F,-.-,+r•••4,�.:L•h,,,�•u••:•:e•+.:;•.•.' Maxtrrwm Output Current 15 • Adc „ 60 it Vdc OUTPUT DURING STANDBY -(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) gip' r Salary Output Vdtogo par Power Opdmlzdr 1 Power OptlmkerSped/kation-P300/P350/P400/P40S SOIaP' • • Power Optimizer Specifications - P300 / P350 ! P400 / P405 P300 PJ50 Pt00 1 T . P40S . . F- Minimum String Length (Power Optimizers) , ' 8 10 18 Rated Input DC Powel'1 - 100 JSD 400 415 w Absolute Maximum Input Voltage (Vac) 18 fi0 80 125 Vdc MPPT Operating Range 8-48 8-80 12.5-106 Vdc Maximum Soon Circuit Current (Ise) of connected PV Modute 10 Aae Maxlmum OC Input Currer4 12.5 % Maximum Efficiency 99.5 85 Weighed Efficiency "•8 Ovorvoltago Category II ;OUTP.UT.Ot1RING OPERATION:(POWER'OP,TIMIZER'CONNECTED TO`.OPERATING tNVEfiTER)�c-=•,; ,••�,.,,ti .�}F,-.-,+r•••4,�.:L•h,,,�•u••:•:e•+.:;•.•.' Maxtrrwm Output Current 15 Adc Maximum Output Vdlage , 60 � Vdc OUTPUT DURING STANDBY -(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Salary Output Vdtogo par Power Opdmlzdr 1 v - STANDARD COMPLIANCE; _,ft , 1 • �:a�: - _ . 1 .. --,- - EMC FCC Part15 Class B, IE1:6100118.2, IECBt0011-G•J Safety IEC82.0&r(etaas n safely), UU7at Material UL -99 (5 -VA), UV Resistant RoHS _ 1'bs INSTALWTION.SPECIflCATIONS? - • ••? 3;• Maximum Allowed System VdWge 1000 Vdc Ofmonsions (WxLxH) � 147 %214 x 40.5 7 5.55 z 9114 x 1.59 rnm f in Weight (including cables) 95012.1 glib .. in Rated STC po-of the module. Module of up to -5% power tolerances a9owed MCA / 7yoa I Amprgrwl Output Wire Type i Connector Double insulated; Ampherol Output Wire Length 0.95 i J.0 1.2119 m 'It Operating Temperature Range 40 •+e5 1.40 • • 185 'C I •F PrIXed'gn Rating Soilorfte PopwerOptimIzers 1 PV SYSTEM DESIGN USINO'SOLAdFAGE INVERTER :' •� �'� P300 PJ50 Pt00 1 T . P40S . . F- Minimum String Length (Power Optimizers) , ' 8 10 18 Rated Input DC Powel'1 - 100 JSD 400 415 w Absolute Maximum Input Voltage (Vac) 18 fi0 80 125 Vdc MPPT Operating Range 8-48 8-80 12.5-106 Vdc Maximum Soon Circuit Current (Ise) of connected PV Modute 10 Aae Maxlmum OC Input Currer4 12.5 % Maximum Efficiency 99.5 85 Weighed Efficiency "•8 Ovorvoltago Category II ;OUTP.UT.Ot1RING OPERATION:(POWER'OP,TIMIZER'CONNECTED TO`.OPERATING tNVEfiTER)�c-=•,; ,••�,.,,ti .�}F,-.-,+r•••4,�.:L•h,,,�•u••:•:e•+.:;•.•.' Maxtrrwm Output Current 15 Adc Maximum Output Vdlage , 60 � Vdc OUTPUT DURING STANDBY -(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Salary Output Vdtogo par Power Opdmlzdr 1 v - STANDARD COMPLIANCE; _,ft , 1 • �:a�: - _ . 1 .. --,- - EMC FCC Part15 Class B, IE1:6100118.2, IECBt0011-G•J Safety IEC82.0&r(etaas n safely), UU7at Material UL -99 (5 -VA), UV Resistant RoHS _ 1'bs INSTALWTION.SPECIflCATIONS? - • ••? 3;• Maximum Allowed System VdWge 1000 Vdc Ofmonsions (WxLxH) � 147 %214 x 40.5 7 5.55 z 9114 x 1.59 rnm f in Weight (including cables) 95012.1 glib .. Input Cormeav - MCA / 7yoa I Amprgrwl Output Wire Type i Connector Double insulated; Ampherol Output Wire Length 0.95 i J.0 1.2119 m 'It Operating Temperature Range 40 •+e5 1.40 • • 185 'C I •F PrIXed'gn Rating - IP651 NEMA4 Relative Htonidty ' 0-100 % PV SYSTEM DESIGN USINO'SOLAdFAGE INVERTER :' •� �'� �- t . • SINGLE PHASE: - THREE PHASE 208V THREE PHASE ' Minimum String Length (Power Optimizers) , ' 8 10 18 Maximum String Lergift (Power Optimizers) 25 ` 25 - 50 ' Maximum Power per String 5250 6000 12750 W - Parallel Strings of Different Lengths or Odaraations Yes 4 r a'• - El--I-IC-11Cla1Na[ CLIENT: - REVISIONS: DATE: TITLE: SHEET: - C-10 982892 i DESCRIPTION DATE REVISION 12/07/2016 • :C Freedom Sotar SCOTT RON N I E & TANYA .fir' .. - _ DESIGN DATA SHEET: INVERTER 2068 TEHAMA AVE, Freedom -Solar Co "` OROVILLE,CA95965 BY: GREG - - PV7 25819 Jefferson Ave, Suite 110, Murrieta, CA 92562 (530)-370 9175 ` JOB Tel: (951) 321-0855 NO,: FS -12-029 2 II I ON, R I DGE Flush Mount System e_. I Built for soiars toughest roofs. IronRIdge builds the strongest mounting system for pitched roofs In solar. Every component has been tested to the limit and proven In extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and Is also why our products are fully certified, code compliant and backed by a 20 -year warranty. Strength Tested PIE Certified All components evaluated for superior Pre -stamped engineering letters structural performance. available In most states. ClassA Fire Rating., Design Assistant Online software makes it simple to rating of the existing roof. create, share, and price projects. Certified to maintain the fire resistance UL 2703 Listed System 20 -Year Warranty Meats newest effective UL 2703 Twice the protection offered by standard. competitors, F7777 SCOTT RONNIE & TANYA 2068 TEHAMA AVE, OROVILLE, CA 95965 (530)-370 9175 XR Rails XR10 Rail XR100 Rail XR1000 Rail Banded Splices A low-proflle mounting rail The ultimate residential A heavyweight mounting All rails use Internal splices for regions with light snow. Solar mounting rail. rail for commercial projects. for seamless connections. • 6'.spanning capability - O'spanning capability - 12'spannIng capability - - - Sol(-drllllng screws Moderate load capability a Heavy load cai)abillty a Extreme load capability a Varyina versions for rails • Clear & black anod, finish - Clear & black anod. finish , Clear anodized finish 4 Forms secure bonding Clamps St Grounding UFOs (9 Stopper Sleeves Grounding Lugo Micro[nverter Kit 0 F, Universal Fastening Objects Snap onto the UFO to turn -Connects array to Mount MIs or POs to XR bond module n equipment groun Ralls. 8 to falls. Into 8. bonded end clamp. �d - Fully assembled & lubed - Bonds modules to rolls - Low profile, Bonds devices to rails - Single, universal size - 6 different sizes , Single tool Installation Kit comes assembled - Clear& black i1nIsh - Clear & black anod. finish - Mounts In any -direction Listed to UL 2703 Attachments FlashFoot Banded L -Feat 9 Standoffs Anchor, flash, and mount with Drop-in design for rapid rail Raise Flush Mount System to various all -In -one attachments, attachment. heights. - Ships with all hardware . Bonding hardware Included - Works with vent flashing - IBC & IRC compliant - Forms secure rail connection - Ships assembled - Certified with XR Rails - Clear & black anod. finish - 4" and 7" Lengths Resources Design Assistant 1h. A Ad NABCEP Certified Training Go from rough layout to fullyg education credits, i earn free continuing engineered system, For free. while learning more about our systems. j GotolronRidge.ciam/dosign 00 to IronRiduaicorn/trainIng REVISIONS: DATE: DESCRIPTION DATE REVISION 12/07/2016 DESIGN BY: GREG JOB NO.: FS' -12-029 TITLE: ' SHEET: DATA SHEET: RAIL PV7A - E