Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B17-0041 030-063-009 (2)
Butte County Department of Development Services - TIM SNELLINGS, DIRECTOR I PETE CALARCO, ASSISTANT DIRECTOR' " 7 County Center Drive M�¢ Oroville, CA 95965 (530) 538-7601 Office (530) 538-7785 Fax. www.buttecounty.net www.buttegeneralblan.net INSTALLATION, OF WATER -CONSERVING PLUMBING FIXTURES:, SB 407..0 California Civil Code Section 1.101-.1 a 2013.Green:Buiiding Standards Code ,• :. In -2009, the California. State :Legislature:passed: Senate. Bill SB 407 which requires the replacement of ,plumbing fixtures that are not. waterconserving;,effective January. 1, 2014. Similar provisions -are found in both.the California Civil Code and,the=2013, California -Green -Building Standards.Code. This .� `• informational bulletin has:been issued by -Butte County. -to clarify how these regulations shall,be applied by this jurisdiction. .Each one of these codes and regulations make reference to the.requirements.for replacement of non- compliant plumbing fixtures -with water -conserving; plumbing fixtures -when a property is undergoing ,.: alterations or improvements: - The definition ofan "alteration" in the California Building Standards Code is "Any construction or,renovation'to an existing structure other than,a.repair or addition." Based on this definition; any building. permit• issued, fortheTepairor maintenance of an existing structure. would not be subject to the requirements of Senate Bill AB .407. With respect to "alterations", Section .301. 1.1 of the California Green. Building Standards Code specifies the. requirements shall apply only to the specific area of the addition or alteration. (Please refer to the attached flowchart, and CALBO Legislative Analysis for further clarification) Solar Photovoltaic Systems have been aggressively promoted in the State of California with directives and recommendations from the Governor's Office and the .State Legislature, and to facilitate their ihstallation and use. For example, Senate Bill SB 1222 was enacted to provide guidelines related to the reasonable cost of permit fees for the installation of rooftop solar energy systems. The application of SB 407 when a solar photovoltaic system is installed on an existing building would incur additional costs and associated permit fees which wouldbe in conflict with the .requirements and intent of SB 1222. Based on this, and the provisions.of the California Green Building Standards Code related to the specific area of the, alteration; Solar Photovoltaic Systems shall not be subject to the requirements of SB 407. Therefore, effective January 1, 2014, the. -following permits shall not be subject to SB 407 in the County of Butte: • Electrical service change -outs • HVAC and other mechanical change -outs • Re -roofs • Sewer line replacement • Siding or stucco replacement • Site work: retaining walls, fences, walk ways, etc. • Water heater replacement • Window replacement • Residential solar systems • Swimming pools • Other minor repairs or maintenance as determined by the Building Official All other provisions of SB 407 shall be enforced such as additions or alterations. 01/01120141SB 407 Interpretation handout SB -407, Padilla Property Transfers: plumbing fixtures replacement Effective January 1, 2014 Civil Code - Section 1101.1 2013 Green Building Code Section 301.1.1— Additions & Alterations. Project: submitted to AHJ �Is this.project an� addition. or Alteration Yes- it meets the definition of'an Addition or Alteration as determined by the AHJ ADDITION- AN EXTENSION OR INCREASE IN FLOOR AREA OF AN EXISITNG BUILDING OR STRUCUTURE ALTERATION- ANY CONSTRUCTION OR RENOVATION TO AN EXISTING STRUCUTURE OTHER THAWREPAIR FOR THE PURPOSE OF MAINTENANCE OR . ADDITION Replace non-compliant plumbing fixtures Toilet > 1.6 GPF Urinal > 1.0 GPF Showerhead > 2.5 GPM Interior Faucet,> 2.2 GPM ELEC. SERVICE CHANGE -OUT r WINDOW PREPLACEMENT ' WATER HEATER REPLACEMENT SIDING OTHER MINOR REPAIRS AS DETERMINED BY AHJ DIVISION A4.6 - TIER 1 AND TIER 2=continued, SECTION A4.60`2 • RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST • ' _ Effective July 1, 2015 j continued + 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE 4 83 LEVELS VERIFICATIONS t, APPLICANT TO SELECT ELECTIVE MEASURES ENFORCING AGENCY TO SPECIFY t. VERIFICATION METHOD FEATURE OR MEASURE c r' Prerequisites_ and electives Enforcing Installer or Third Agency Designer. party " Mandatory Tier 1 Tier 2 All All All PLANNING AND DESIGN , Si a •,�. rte. ... ..,.r .. ,.y+ 4 , YI �N'i ci' .t 7'„ ,• `S",.,_ti. r A4.103.1 A site which complies with at least one of the following characteristics is selected: 1. An infill site is selected. p +❑ ❑ : ' ❑ ❑ 2. A greyfield site is selected. ❑ ❑ ❑ ' ❑ ❑ '3. An EPA -recognized Brownfield site is selected. ❑ ❑ ❑ ❑ ❑ A4.103.2 Facilitate community connectivity by one of the following methods: 1. Locate project within a'/; mile true walking distance of at least 4 ❑ ❑ ❑ ❑ ❑ , basic services; 2. Locate project within '/Z mile true walking distance of at least 7 ❑.. ❑ ❑ ❑ ❑ basic services; 3. Other methods increasing access to additional resources. ❑ ❑ ❑ ❑ ❑ Site Preservationt,.i4a'�"'ra a Y;4 j�� A4.104.1 An individual with oversight responsibility for the project has participated in an educational program promoting + ❑ ❑ ❑ ❑ environmentally friendly design or development and has provided training or instruction to appropriate entities. u Deconst� uction and Reuse of EXisting jMatertals A4.105.2 Existing buildings are disassembled for reuse or recycling of building materials. The proposed structure utilizes at least one of the ' following materials which can be easily reused: 1. Light fixtures 2. Plumbing fixtures , ❑ 13 ❑ ❑ ' 0- 3. Doors and trim i °•4. 4. Masonry + 5. Electrical devices 6. Appliances 7. Foundations or portions of foundations Site,Deve_lopment ,,�4 7Y�'� d vri . "t�`: s •;-;raa 4.106.2 A plan is developed and implemented to manage storm water drainage during construction. r 4.106.3 Construction plans shall indicate how site grading or a drainage system will manage all surface water flows to keep water: from entering buildings. - 4.106.4 Provide capability for electric vehicle charging in one- and IBJ ❑ ❑ ❑ ❑ two-family dwellings and in townhouses with attached private. garages; and 3 percent of total parking spaces, as specified, for multifamily dwellings. ' A4.106.1 Reserved' ❑ ❑ ❑ ❑ ❑ j continued + 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE 4 83 RESIDENTIAL VOLUNTARY MEASURES SECTION A4.602 RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST—continued continued 84 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE LEVELS VERIFICATIONS APPLICANT TO SELECT ELECTIVE MEASURES ENFORCING AGENCY TO SPECIFY VERIFICATION METHOD FEATURE OR MEASURE Prerequisites and electives' Enforcing installer or Third Agency Designer party ❑ ❑ ❑ Mandatory Tier 1 Tier 2 All All All A4.106.2.1 Soil analysis is performed by a licensed design professional and the findings utilized in the structural design of the ❑ ❑ ❑ ❑ ❑ building. A4.106.2.2 Soil disturbance and erosion are minimized by at least one of the following: 1. Natural drainage patterns are evaluated and erosion controls are ❑ ❑ ❑ ❑ ❑ implemented to minimize erosion during construction and after occupancy. 2. Site access is accomplished by minimizing the amount of cut and ❑ ❑ ❑ ❑ ❑ fill needed to install access roads and driveways. 3. Underground construction activities are coordinated to utilize the ❑ ❑ ❑ ❑ ❑ same trench, minimize the amount of time the disturbed soil is exposed and the soil is replaced using accepted compaction . methods. A4.106.2.3 Topsoil shall be protected or saved for reuse as specified ❑ ❑ ❑ in this section. Tier 1. Displaced topsoil shall be stockpiled for reuse in a ---- 02 px z -designated-area-and covered or -protected from -erosion- - - - - ^ - - -- - -- - — - Tier 2. The construction area shall be identified and delineated by [K2 fencing or flagging to limit construction activity_ to the construction _.area... --- --- A4.106.3 Postconstruction landscape designs accomplish one -or - -- •............ -- •- - •- • • •_ - more of the following: 1. Areas disrupted during construction are restored to. be consistent ❑ ❑ ❑ ❑ ❑ with native vegetation species and patterns. 2. Utilize at least 75 percent native California or drought tolerant ❑ ❑ ❑ ❑ ❑ plant and tree species appropriate for the climate zone region. A4.106.4 Permeable paving is utilized for the parking, walking or patio surfaces in compliance with the following: Tier 1. Not less than 20 percent of the total parking, walking or pz ❑ ❑ ❑ patio surfaces shall be permeable. Tier 2. Not less than 30 percent of the total parking, walking or px ❑ ❑ ❑ patio surfaces shall be permeable. A4.106.5 Roofing materials shall have a minimum 3 -year aged.solar reflectance and thermal emittance or a minimum Solar Reflectance Index (SRI) equal to or greater than the values specified in Tables A4.106.5.1(1) and A4.106.5.1(2) for low-rise residential buildings and Tables A4.106.5.1(3) and A4.106.5.1(4) for high rise residential buildings. Low-rise Residential Tier 1 roof covering shall meet or exceed the values contained in p2 Table A4.106.5.1(1). Tier 2 roof covering shall meet or exceed the values contained in px a Table A4.106.5.1(2). High-rise Residential, Hotels and Motels Tier 1 roof covering shall meet or exceed the values contained in ❑x a Table A4.106.5.1(3). Tier 2 roof covering shall meet or exceed the values contained in p2 Table A4.106.5.1(4). continued 84 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE RESIDENTIAL VOLUNTARY MEASURES SECTION A4.602 RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST --continued LEVELS VERIFICATIONS - APPLICANT TO SELECT ELECTIVE MEASURES ENFORCING AGENCY TO SPECIFY VERIFICATION METHOD FEATURE OR MEASURE Prerequisites and electives' Enforcing Installer or Third Agency Designer party ❑ ❑ ❑ Mandatory Tier 1 Tier 2 All All All A4.106.6 Install a vegetated roof for at least 50 percent of the roof area. Vegetated roofs shall comply with requirements for roof ❑ ❑ ❑ ❑ ❑ gardens and landscaped roofs in the California Building Code, Chapters 15 and 16. A4.106.7 Reduce nonroof heat islands for 50 percent of sidewalks, patios, driveways or other paved areas by using one or more of the ❑ ❑ ❑ ❑ p methods listed. A4.106.8.1 Tier 1 and Tier 2 for one- and two-family dwellings and townhouses with attached private garages. Install a dedicated 208/240 -volt branch circuit, including an ❑ m2 02 ❑ 0 ❑ overcurrent protective device rated at 40 amperes minimum per . dwelling unit. A4.106.8.2 Tier 1 and Tier 2 for multifamily dwellings. Provide capability for future electric vehicle charging in ❑ ®? p2 ❑ ❑ ❑ 5 percent of total parking spaces, as specified. ' 4.106.9 Provide bicycle parking facilities as noted below or meet a ❑ ❑ ❑ local ordinance, whichever is more stringent. Number of bicycle • - parking spaces maybe reduced, as approved by the enforcing agency, due to building site characteristics, including but not limited to, isolation from other development. ❑ p ❑ ❑ 0- 1. Provide short-term bicycle parking, per Section A4.106.9.1. 2. Provide long-term bicycle parking for multifamily buildings, per • ❑ ❑ ❑ ❑ ❑ Section A4.106.9.2. ' 3. Provide long-term bicycle parking for hotel and motel buildings, ❑ ❑ ❑ ❑ ❑ per Section A4.106.9.3. A4.106.10 [HR] Outdoor lighting systems shall be designed and installed to comply with: 1. The minimum requirements in the California Energy Code for Lighting Zones 1-4; and 2. Backlight, Uplight and Glare (BUG) ratings as defined in IES ❑ ❑ ❑ ❑ ❑ TM -15-11; and , 3. Allowable BUG ratings not exceeding those shown in Table A4.106.10; or Comply with a lawfully enacted local ordinance, whichever is more ❑ ❑ ❑ ❑ ❑ stringent. i RESIDENTIAL VOLUNTARY MEASURES SECTION A4.602 RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST—continued 86 continued 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE LEVELS VERIFICATIONS APPLICANT TO SELECT ELECTIVE MEASURES ENFORCING AGENCY TO SPECIFY VERIFICATION METHOD FEATURE OR MEASURE Prerequisites and electives' Enforcing Installer or Third Agency Designer party ❑ ❑ ❑ Mandatory Tier 1 Tier 2 All All All InnOvattve JC6ik0'6_a - n & Local; Environmental Con_dItions A4.108.1 Items in this section are necessary to address innovative concepts or local environmental conditions. , Item 1 ❑ ❑ ❑ ❑ ❑ ❑, Item 2 ❑ ❑ ❑ ❑ ❑ ❑ Item 3 ❑ ❑ ❑ ❑ ❑ p ENERGY EFFICIENCY+s+k�;ht Generale~ lW"'We � r 1 -ti, ` I> 4.201.1 Building meets or exceeds the requirements of the California 0 �2 02. [3 ❑ Building Energy Efficiency StandarV. Performance Approach for Newlyn ConstivctedBm(dings "r_.s"r:`'+ .� -- --- —�-- ---- — -- A4.203.1.1.1 An Energy Design Rating for the Proposed Design ©2 (E]2 ❑ ❑ ❑ -Building is included-in-the-Certmfirate-of-Compliance:docummtation- A4.203.1.1.2 Q11procedures specified in the Building Energy - Efficiency Standards Reference Residential -Appendix RA3 5 are 02 l]2 "' '❑."' " ` .❑ ' ' '' ❑ -' completed. _ A4.203.1.2.1 Tier 1: Buildings complying with the fust level of advanced energy efficiency shall have either an Energy Budget that t is no greater than 85 percent of the Title 24, Part 6 Energy Budget for the Standard Design Building,.or. an Energy Design Rating showing.a OO 2 , ❑ w ❑ ❑ 15% or greater reduction in its Energy Budget component compared ! to the Standard Design Building, as calculated by Title 24, Part 6 Compliance Software approved by the Energy Commission. A4.203.1.2.2 Tier 2: Buildings complying with the second level of advanced energy efficiency shall have either an Energy Budget that is no greater than 70 percent of the Title 24, Part 6 Energy Budget for ' the Standard Design Building, or an Energy Design Rating showing a 02 ❑ ❑ ❑ 30% or greater reduction in its Energy Budget component compared to the Standard Design Building, as calculated by Title 24, Part 6 Compliance Software approved by the Energy Commission. A4.203.1.2.3 Zero Net Energy Design (elective): Shall comply with ❑ ❑ ❑ ❑ ❑ all of the following: 1. Section A4.203.1.1 (Prerequisite) and - 2. Section A4.203.1.2.1 • for single-family buildings in Climate Zones 6 and 7, and low- rise multifamily buildings in Climate Zones 3, 5, 6, and 7 or Section A4.203.1.2.2 • for single-family buildings in Climate Zones 1-5 and 8-16, and low-rise multifamily buildings in Climate Zones 1, 2, 4, and 8-16 3. Energy Design Rating of zero (0) or less " Pe'rfot mance'Approech for.'Add►ttons {o-� A4.204.1.1 Tier 1. If only one mechanical system is added or modified, the Energy Budget is no greater than 95 percent of the Title 24, Part 6, Energy Budget for the Standard Design Building. If two or Ell 13 ❑ more mechanical systems are added or modified, the Energy Budget is no greater than 90 percent of the Title 24, Part 6, Energy Budget for the Standard Design Building. y A4.204.1.2 Tier 2. If only one mechanical system is added or modified, the Energy Budget is no greater than 90 percent of the Title 24, Part 6, Energy Budget for the Standard Design Building. If two or O2 ❑ ❑ ❑ more mechanical systems are added or modified, the Energy Budget , is no greater than 85 percent of the Title 24, Part 6, Energy Budget for the Standard Design Building. 86 continued 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE RESIDENTIAL VOLUNTARY MEASURES SECTION A4.602 RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST—continued continued i 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE 87 LEVELS VERIFICATIONS APPLICANT TO SELECT ELECTIVE MEASURES ENFORCING AGENCY TO SPECIFY VERIFICATION METHOD FEATURE OR MEASURE Prerequisites and electives' Enforcing Installer or Third Agency Dealgner party Mandatory Tier 1 Tier 2 All All All WATER' FICIENCXNANW ONSERVATION IndoorjWatei;Use 4303.1 Plumbing fixtures (water closets and urinals) and fittings (faucets and showerheads) installed in residential buildings shall El ❑ ❑ ❑ comply with the prescriptive requirements of Sections 4.303.1.1 through 4.303.1.4.4. 4.303.2 Plumbing fixtures and fittings required in Section 4.303.1 shall be installed in accordance with the California Plumbing Code, El ❑ ❑ •' ❑ and shall meet the applicable referenced standards. A4.303.1 Kitchen faucets. The maximum flow rate of kitchen faucets shall not exceed 1.5 gallons per minute at 60 psi. Kitchen faucets may temporarily increase the flow above the maximum rate, but not to exceed 2.2 gallons per minute at 60 psi, and must default to ❑ ❑ ❑ ❑ ❑ a maximum flow rate of 1.5 gallons per minute at 60 psi. Note: Where complying faucets are available, aerators or other means may be used to achieve reduction. A4.303.2 Alternate water source for nonpotable applications. Alternate nonpotable water sources are used for indoor potable water 13 ❑ ❑ ❑ • ❑ reduction. Alternate nonpotable water sources shall be installed in accordance with the California Plumbing Code. A4.303.3 Install at least one qualified ENERGY STAR dishwasher ❑ ❑ 13 ❑ ❑ or clothes washer. A4.303.4 Nonwater supplied urinals or waterless toilets are installed. ❑ ❑ ❑ ❑ 1 ❑ A4.303.5 Hot water recirculation systems. One- and two-family dwellings shall be equipped with a demand hot water recirculation system, as defined in Chapter 2. The demand hot water recirculation system shall be installed in accordance with the California Plumbing Code, California Energy Code, and the manufacturer's installation instructions. Outdo6r Water Use 4304.1 After December 1, 2015, new residential developments with ❑x ❑ an aggregate landscape area equal to or greater than 500 square feet shall comply with one of the following options: 1. A local water efficient landscape ordinance'or the current ❑ ❑ California Department of Water Resources' Model Water Efficient Landscape Ordinance (MWELO), whichever is more stringent; or 2. Projects with aggregate landscape areas less than 2,500 square ❑ ❑ feet may comply with the MWELO's Appendix D Prescriptive Compliance Option. A4.304.1 Rainwater catchment systems. An approved rainwater catchment system is designed and installed to use rainwater generated by at least 65 percent of the available roof area. Rainwater ❑ ❑ ❑ ❑ ❑ catchment systems shall be designed and installed in accordance with the California Plumbing Code. A4304.2 Potable water elimination. When landscaping is provided and as allowed by local ordinance, a water efficient landscape irriga- tion design that eliminates the use of potable water beyond the initial requirements for plant installation and establishment should be pro- vided. Methods used to accomplish the requirements of this section must be designed to the requirements of the California Building Stan- dards Code and shall include, but not be limited to, the following: ❑ ❑ ❑ ❑ ❑ 1. Use of captured rainwater. 2. Use of recycled water. 3. Water treated for irrigation purposes and conveyed by a water district or public entity. 4. Use of graywater. A4.304.3 For new water service connections, landscaped irrigated areas less than 5,000 square feet shall be provided with separate ❑ ❑ ❑ ❑ ❑ submeters or metering devices for outdoor potable water use. continued i 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE 87 RESIDENTIAL VOLUNTARY MEASURES SECTION A4.602 RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST—continued 88 continuid" 44 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE LEVELS APPLICANT TO SELECT ELECTIVE MEASURES VERIFICATIONS ENFORCING AGENCY TO SPECIFY VERIFICATION METHOD FEATURE OR MEASURE.rerequisites and electives' Enforcing Installer or Third -Agency Designer party Mandatory Tier 1 Tier All All, All WATTRREUSE -SYSTEMS .AW 4, dil A4305.1 Piping is installed to permit future use of a graywater 0 0 0 irrigation system served by the clothes washer or other fixtures. A4.305.2 Recycled water piping is installed. 0 0 0 0 0 A4.305.3 Recycled water is used for. landscape irrigation. 0 0 0 0 0 Innovative oricivts.-aii&Lb61 En - rhmiiental.Condi A4.306.1 Items in this s ' ection are necessary to address innovative concepts or local environmental conditions. Item 1 y 0 0.- El 0 13. 0 Item 2 0 [3 11 0, 0 0 Item 3 0 E3 11 0 0. 0 MATERTAUCONSIF, !A RESOURCE" ..... EFFICIENCY ...... Foundation 'Sj9tems,*.v,4, -X4.-403-.1—A7Frost --ptotected-StiaUbw-Fourfda6oa-(FPSF)-ig-iie7sigifed— and A4.403.2 Cement use in foundation mix design is reduced. Tier 1. Not less than a 20 percent reduction in cement use. 02 Tier 2. Not less than a 25 percent reduction in cement use. 'Effici, nt Framing,T A4.404.1 Beams and headers and trimmers are the minimum size to adequately support the load. A4.404.2 Building dimensions and layouts are designed to minimize [3 ❑ waste. A4.404.3 Use premanufactured building systems to eliminate solid [3 El [3 sawn lumber whenever possible. A4.404.4 Material lists are included in the plans which specify E3 13 0 Ej material quantity and provide direction for on-site cuts. 88 continuid" 44 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE RESIDENTIAL VOLUNTARY MEASURES SECTION A4.602 RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST—continued continued 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE 89 LEVELS VERIFICATIONS APPLICANT TO SELECT ELECTIVE MEASURES ENFORCING AGENCY TO SPECIFY VERIFICATION METHOD FEATURE OR MEASURE Prerequisites and electives' Enforcing Installer or Third Agency Designer party ❑ ❑ ❑ Mandatory Tier 1 Tier 2 All All All N14t�� eriF!' oarces'90, A4.405.1 One or more of the following building materials, that do not require additional resources for finishing are used: 1. Exterior trim not requiring paint or stain 0 ❑ ❑ ❑ ❑ 2. Windows not requiring paint or stain 3. Siding or exterior wall coverings which do not require paint or stain A4.405.2 Floors that do not require additional coverings are used including but not limited to stained, natural or stamped concrete ❑ ❑ ❑ ❑ ❑ floors. A4.4053 Postconsumer or preconsumer recycled content value (RCV) materials are used on the project. ❑ 11 Tier 1. Not less than a 10 -percent recycled content value. ®Z Tier 2. Not less than a 15 -percent recycled content value. p2 A4.405.4 Renewable source building products are used. ❑ ❑ ❑ ❑ ❑ Enhanced Durability.-and'Reduckl!Mai tenence 4.406.1 Annular spaces around pipes, electric cables, conduits or other openings in plates at exterior walls shall be protected against the passage of rodents by closing such openings with cement mortar, ® ❑ ❑ ❑ concrete masonry or similar method acceptable to the enforcing agency. ��Water�Resistance�and`Moisture Matingemenf ` A4.407.1 Install foundation and landscape drains. ❑ ❑ ❑ ❑ ❑ A4.407.2 Install gutter and downspout systems to route water at least 5 feet away from the foundation or connect to landscape drains which ❑ ❑ ❑ ❑ ❑ discharge to a dry well, sump, bioswale, rainwater capture system or other approved on-site location. A4.407.3 Provide flashing details on the building pians and comply E .0 ❑ 11 ❑ with accepted industry standards or manufacturer's instructions. A4.407.4 Protect building materials delivered to the construction site ❑ ❑ ❑ ❑ ❑ from rain and other sources of moisture. A4.407.5 In Climate Zone 16 an ice/water barrier is installed at roof ❑ ❑ ❑ ❑ ❑ valleys, eaves and wall to roof intersections. A4.407.6 Exterior doors to the dwelling are protected to prevent ❑ ❑ ❑ ❑ ❑ water intrusion. A4.407.7 A permanent overhang or awning at least 2 feet in depth is ❑ ❑ ❑ ❑ ❑ provided. continued 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE 89 RESIDENTIAL VOLUNTARY MEASURES SECTION A4.602 RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST—continued continued 90 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE LEVELS VERIFICATIONS APPLICANT TO SELECT ELECTIVE MEASURES ENFORCING AGENCY TO SPECIFY VERIFICATION METHOD FEATURE OR MEASURE Prerequisites and electives' Enforcing Installer or Third Agency Designer party ❑ ❑ ❑ Mandatory Tier 1 Tier 2 All All All IConstructron,Waste Rett ction;`Disposal`and Recycling+ t yc,,g 4.408.1 Recycle and/or salvage for reuse a minimum of 65 percent of _ O ❑ ❑ ❑ the nonhazardous construction and demolition waste in accordance with one of the following: 1. Comply with a more stringent local construction and demolition waste management ordinance; or 2. A construction waste management plan, per Section 4.408.2; or 3. A waste management company, per Section 4.408.3; or _ 4. The waste stream reduction alternative, per Section 4.408.4. A4.408.1 Construction waste generated at the site is diverted to recycle or salvage in compliance with one of the following: 1. Tier 1 at least a 65 percent reduction. Any mixed recyclables that OZ ❑ ❑ ❑ are sent to mixed -waste recycling facilities shall include a qualified third party verified facility average diversion rate. Verification of diversion rates shall meet minimum certification eligibility guidelines-acceptable-to-the-local-enforcing,agency:--.- -.— - ---�-- -- --- - - --—r----- 2Tier 2 at least a 75 percent induction with athird-party verification.IS ❑ ❑ r 0 Exception: Equivalent waste reduction methods are developed_ _by working -with local agencies..�- �Building Meiutenance and Operafion�yFxY,`5a" - 4.410.1 An operation and maintenance manual shall be provided to IM ❑ ❑ 0. - •-the the building occupant or owner. 4.410.2 Where 5 or more multifamily dwelling units are constructed El ❑ , _ ❑ ❑.. on a building site, -provide readily accessible areas that serve all. buildings on the site and is identified for the depositing, storage and collection of non-haiardous materials for recycling, including (at a minimum) paper,.corrugated cardboard, glass, plastics, organic waste,'and metals or meet a lawfully enacted local recycling ordinance, if more restrictive. See exception for rural jurisdictions. r Innovative Concepts and Local Environmental Conditions s A4.411.1 Items in this section are necessary to address innovative concepts or local environmental conditions. Item 1 ❑❑ ❑ ❑ ❑ ❑ . . _ .. Item 2 ❑ ❑ ❑ ❑ 0. ❑ Item 3 ❑ - ❑ ❑ ❑ ❑ ❑ IENVIRQN TAL''QUALTTX .Ja.-. ,Preplaces"M 4.503.1 Any installed gas fireplace shall be a direct -vent sealed - combustion type. Any installed woodstove or pellet stove shall comply with U.S. EPA New Source Performance Standards (NSPS) emission limits as applicable, and shall have a permanent label O ❑ ❑ ❑ indicating they are certified to meet the emission limits. Woodstoves, pellet stoves and fireplaces shall also comply with applicable local ordinances. Pollutant Controls:�{� .7r.`�a'a.'� 4.504.1 Duct openings and other related air distribution component ® ❑ ❑ ❑ openings shall be covered during construction. 4.504.2.1 Adhesives, sealants and caulks shall be compliant with © ❑ ❑ ❑ VOC and other toxic compound limits. 4.504.2,2 Paints, stains and other coatings shall be compliant with ® ❑ ❑ ❑ VOC limits. 4.504.2.3 Aerosol paints and coatings shall be compliant with ❑ ❑ ❑ product weighted MIR limits for ROC and other toxic compounds. 4.504.2.4 Documentation shall be provided to verify that compliant ❑ ❑ ❑ VOC limit finish materials have been used. continued 90 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE . RESIDENTIAL VOLUNTARY MEASURES 'A SECTION A4.602 r . Y •� , "' RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST --continued ; +' LEVELS r APPLICANT TO SELECT ELECTIVE VERIFICATIONS ENFORCING AGENCY TO SPECIFY •: MEASURES VERIFICATION METHOD FEATURE OR MEASURE t .t Prerequisites and electives Enforcing Installer or Third • Agency Designer party • c '2 ❑ ❑ ❑ • Mandatory Tier 1':* Tier All All All 4.504.3 Carpet and carpet systems shall be compliant with VOC r © t ❑ ❑ ❑ limits. , 4.504.4 80 percent of floor area receiving resilient flooring shall comply with specified VOC criteria. " 4.504.5 Particleboard, medium density fiberboard (MDF) and hardwood plywood used in interior finish systems shall comply with . • - : , low formaldehyde emission standards. A4.504.1 Use composite wood products made with either California Air Resources Board approved no -added formaldehyde (NAF) resins - "�' ❑' ❑ - ❑' ' • ❑ ❑ or ultra-low emitting formaldehyde (ULEF) resins. A4.504.2 Install VOC compliant resilient flooring systems. — ❑ ❑ ❑ Tier 1. At least 90 percent of the resilient flooring installed shall _ ©2 comply. •' ; :: Tier 2. At least 100 percent of the resilient flooring installed shall ,- • ' .r ®z . ' comply. A4.504.3 Thermal insulation installed in the building shall meet the `_-� . , • ❑ 11 El following requirements: ; Tier 1. Install thermal insulation in compliance with VOC limits. -. - - ® a•" . - - Tier 2. Install insulation which contains No -Added Formaldehyde r- ®z (NAF) and is in compliance with Tier 1. 'Interioi,,WistureiC_onfroL 4.505.2 Vapor retarder and capillary break is installed at slab -on - © — ❑ ❑ ^;, ❑ grade foundations. ; 4.505.3 Moisture content of building materials used in wall and floor. ® ❑ ❑ ❑ framing is checked before enclosure. Z. Indooi''Air OuAhty and,l±rhaust7WA e4r_V ),'+ t; _ A4.506.1 Retum air filters with a value greater than MERV 6 shall be installed on HVAC systems. Pressure drop across the filter shall not ❑ •F +, - ❑ ❑ ❑' . exceed 0.1 inches water column. v A4.506.2 [HRj Provide filters on return air openings rated MERV 6 ' or higher during construction when it is necessary to use HVAC "t • ❑ ' , ❑ [1 ❑•• ❑ r equipment. I , - . A4.506.3 Direct -vent appliances shall be used when equipment is located in conditioned space; or the equipment must be installed in an j ,' ❑ ❑ ; ❑ ❑ ❑ isolated mechanical room. continued Lj . �ter' � . � - • - - ..- !- • •' It 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE a 91 . RESIDENTIAL VOLUNTARY MEASURES i i SECTION A4.602 • - �; RESIDENTIAL OCCUPANCIES APPLICATION CHECKLIST—continued 1. Careen building measures Listed in this table may be mandatory it adopted by a city, county, or city and county as specified in Section 101.7. 2. Required prerequisite for this Tier: - - 3. These measures are currently required elsewhere in statute or in regulation. r ' ' •tel .,. , 92 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE 5 LEVELS w APPLICANT.TO SELECT ELECTIVE MEASURES VERIFICATIONS - ENFORCING AGENCY TO SPECIFY ' VERIFICATION METHOD FEATURE OR MEASURE Prerequisites and electives' Enforcing Installer or Third Agency Designer party ❑ ❑ ❑ Mandatory Tier 1 Tier 2 All All All Environmentiil Comforfti;ilrr 4.507.2 Duct systems are sized, designed, and equipment is selected using the following methods: 1. Establish heat loss and heat gain values according to ANSUt. ACCA 2 Manual J-2011 or equivalent. ❑x " ❑ ❑ ❑ 2. Size duct systems according to ANSUACCA I Manual D-2014 r f or equivalent. 3. Select heating and cooling equipment according to ANSUACCA' ` 3 Manual S-2014 or equivalent. OutdoorAir Qualrt}t.? ;s' rtx r C'] En Q. Inriova_hve Concepts and Locaf Envrr_onmentidConditronsW,f A4.509.1 Items in this section are necessary to address innovative concepts or local environmental conditions. —Item -1-- •---------- ------ -- - -- - .. p—:-- ❑,— ---❑_ —_—_:._❑-----�-�.. Item 2 ❑... ❑ ❑ ❑ ❑ Item 3_.— ❑ --. -.,.. ❑ Installer and Spec�alIn'spector Qualtficatrons .¢, f' ` •,...rSi.Sfi2'3�-..Y yf; a • - 1 702.1 HVAC system installers are trained and certified in the proper • - ❑ ❑ ❑ installation of HVAC systems. . ® ,,' - 702.2 Special inspectors employed -by the enforcing agency must be qualified and able to demonstrate competence in the discipline they ® ❑ ❑ ❑ are inspecting. l,Verifications 703.1 Verification of compliance with this code may -include construction documents, plans, specifications builder or installer • ® _ . ❑ ❑ ❑ certification, inspection reports, or other methods acceptable to the , . enforcing agency which show substantial conformance. ' 1. Careen building measures Listed in this table may be mandatory it adopted by a city, county, or city and county as specified in Section 101.7. 2. Required prerequisite for this Tier: - - 3. These measures are currently required elsewhere in statute or in regulation. r ' ' •tel .,. , 92 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE 5 W r i Butte County Department of Development Services PERMIT CENTER' 7 County Center Drive, Oroville, CA 95965 . Main Phone 530.538.7601 Fax 530.538.7785 www.buttecounty.net/dds PLEASE PRINT CLEARLY PROPERTY OWNER INFORMATION Lest Name First Name Mailing Adifflass t65% 0-m irille- city U City�. state—Cr Zp Phone State Fax �y Email hcaTR tr.. All ojiaT � Cal oqwer a CONTRACTOR Name Mailing A ress Mailing Ad ess tS City�. State Zip I It f- State Z Phone Fax Fax Email Email r Cell ec CA State License No MIA Sa., • �, License No. 00A C31 P. Class i APPLICANT ARCHITECT/ENGINEER Name Mailing Ad ess tS Mail' Address r k Ci 030 • C>bl State Z Phone 5 Ceti Fax Email City Cell 8 - btf CA State License No MIA :/tciismaps.buftecounty.net/flexviewer/bodateseaT&Lndex.html APPLICANT Last Name First Name Mailing Ad ess tS City, tkkA- to CA Z 030 • C>bl Phone —qq0 _%6b C�� Fax Email Ceti PERMIT NO: FORM NO D 11 BP;1 BIN NO: WORKER'S COMPENSATION F Policy Number lto Al PROJECT LOCATION APN stnxhnes) are issued by the State. Tell staff If this permit is for a Mobile Home. Click r LENDING AGENCY Name 030 • C>bl - Property Address • b City Location must not be in the city limits or Chico, GrItIley, Oroville or Paradise, h_ptt :/tciismaps.buftecounty.net/flexviewer/bodateseaT&Lndex.html WORKER'S COMPENSATION F Policy Number lto Al Carder If hiring other than a licensed contractor, a certificate of worker's compensation must be shown at the time of permit issuance stnxhnes) are issued by the State. Tell staff If this permit is for a Mobile Home. Click r LENDING AGENCY Name Mailing Address City State ZIP DESCRIPTION. OR SCOPE OF WORK D Mobile Home permits (other than installation, foundation, utilities & non-attached stnxhnes) are issued by the State. Tell staff If this permit is for a Mobile Home. Click Z below to see Manufactured Home Alterations and Permit Guidelines at: httpj/ m.hod.ca.goy/codesfmhpMCP Phone(91612&5-2501 Is this a ManufacturodlMoblle Home (elmle one) Yes / Czourc►g�. re�o��o>n , JOB VALUATION: (Enter value of labor, Including l noncon6acted, plus materials charge) 1a 12, S uare Peet Detail Living Area: Garage: (Open Area: , Covered Area: TOTAL SQ: O fi Structure Built without permits r Proposed Change of Occupancy/Use, - Note previousi urtent use below. FOR OFFICE USE ONLY Zoning: Flood Zone SRA IYES E3 IN01RNPDES YES 0 NO Code Ent., YES E3 NO Q Legal Lot YEs O NO Occupancy 7Z 2 Type Construction V r7 Pe it Tech: Date: 117 A;, 'When filed, this application and all supporting material become ubject to the Califomia Public Records Act. All public information related to this application is subject to public inspection and will be posted on the Con ty's website for electronic access. , FRU Revised 7.20.2015 , 'a •` r Page 1 of 1 J Butte County Department of Development Services PERMIT CENTER 7 County Center Drive, Oroville, CA 95965 Main Phone 530.538.7601 Fax 530.538.7785 www.buttecounty.neddds IMPORTANT! NOTICE TO PROPERTY OWNER FORM NO Dear Property Owner: An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified at f f[ycQ., GCQ5-�- �J� ,rOU tr, Q �65— We are providing you with an Owner -Builder Acknowledgment and Information Verification Form to make you aware of your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this . form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owner, obtain the prior approval of the permitting authority. OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION DIRECTIONS: Read and initial each statement below to signify that you understand or verify this information. .I understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner -Builder" building permit that erroneously implies that the property owner is providing his or her own labor and material personally. 1, as an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers on my property. 2 I understand building permits are not required to be signed by property owners unless they are responsible for the construction and are not hiring a licensed Contractor to assume this responsibility. *-.3-I understand as an "Owner -Builder" I am the responsible party of record on the permit. I understand that I may protect myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my own. *-4-1 understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on permits and contracts. 5. 1 understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer" under state and federal law. 6. 1 understand if I am considered an "employer" under state and federal law, 1 must register with the state and federal government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial risk. . I understand under California Contractors' State License Law, an Owner -Builder who builds single-family residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building Contractor. Page I of 2 Revised 7.20.2015 *_8. I understand as an Owner-Builder if I sell the property for which this permit is issued, I may be held liable for any financial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the workmanship or materials. le-9-1 understand I may obtain more information regarding my obligations as an "employer" from the Internal Revenue Service, the United States Small Business Administration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1-800- 321-CSLB (2752) or www.csib.ca.gov for more information about licensed contractors. 0. I am aware of and consent to an Owner-Builder building permit applied for in my name, and understand that I am the party legally and financially responsible for proosed construction activity at the following address: _1652 Cie,, Merit � `Q �],s�t�S l l . I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all applicable laws and requirements thatg overn Owner- Builders as well as employers. qgE_12. I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial . loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner-Builder and wish to hire Contractors, you willbe responsible for verifying whether or not those Contractors are properly licensed and the status of their workers' compensation insurance coverage. Before a building permit can be issued, this form must be completed and signed by the property owner and returned to the agency responsible for issuing the permit. Note: A copy of the property owner's driver's license, form notarization, or other verification acceptable to the agency is required to be presented when the permit is issued to verify the property owner's signature. Signature of property owner: Date: Note: The following Authorization Form is required to be completed by the property owner only when designating an agent of the property owner to apply for a construction permit for the Owner -Builder. AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner -Builder Permit for my project. Scope of Construction Project (or Description of Work): Project Location or Address: Name of Authorized Agent: Address of Authorized Agent: Tel No: I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and certify its accuracy. Note: A copy of the owner's driver's license, form notarization, or other verification acceptable to the agency is required to be presented when the permit is issued to verify the property owner's signature. Property Owner's Signature: Date: Revised 7.20.2015 Page 2 of2 I Y644 V/ t i 1 Department of Development Services i Tim Snellings, Director I I i Pete Calarco, Assistant Director e 7 County Center Drive' T: 530.538.7601 Buttecounty.net/dds Oroville, California 95965 F: 530.538.7785 DEVELOPMENT SERVICES i NOTICE TO BUILDERS** Before your building permit can be issued, your plans must be checked for compliance with the California Building Codes. In addition, your plans are routed to other regulatory entities including but not limited to Planning, Public Works, Environmental Health, and the California Department of Forestry for their clearances and,approvals. There are some things you can do to expedite your permit: - 'Make sure your application is complete. - Be responsive to requests from County departments for any additional materials or requirements. The Building Division places its highest priority on processing building permits as quickly as possible and each day that passes without a complete application adds to processing time. "Every permit issued by the Building Official shall expire and become null and void if the work authorized by such permit is not started or completed within one year from the date of issuance of such permit (per Butte County Coder Chapter 26, Article 1, Section 263.1). A permit may be renewed (for a fee) prior to expiration a maximum of two (2) times, provided construction progress has been documented by the Building Division .during each year during scheduled inspections. No changes may be made in the original plans and specifications for such work. In order to reinstate action on a permit after expiration, the permittee shall pay anew full permit fee and additional plan checking and documentation may be required. Upon completion of work covered by this permit, please contact this ,office for final inspection. As a reminder to you, it is illegal to occupy this building or any portion of the building for which this permit is issued without a final inspection. EXPIRATION OF PERMIT APPLICATION AND REFUND POLICY" Application for which a permit has not been issued will expire one year after date of application. Refunds may only be -made upon written request by the person who originally paid the fees. Refunds for permit applications, if the permit has not issued, but not after 180 days from the date of fee payment. Fees paid at the time of application are for Plan Check and administration. The Plan Check portion of fees is refundable only if the permit is cancelled or withdrawn before any plan checking is done. Building Division costs will be deducted prior to authorizing a refund and a charge to process the refund application will be assessed. The current refund processing fee is $127.00. Refunds on permits (issued) may be requested prior to the expiration of the permit, provided no work has been done pursuant to the permit. An Inspection may be required (and deducted from any refund amount) to determine no work was done. Fee/refund information can be read on-line at http://municipalcodes.lexisnexis.com/codes/butteco/ "When filed, this application and all supporting material becomes subject to the California Public Records Act. All public information related to this application is subject to public inspection and will be posted on the County's website for electronic access. Permit Number: B17-0041 Date: 1/9/2017 Parcel Number: 030-063-009 t Location: 1658 CREST DR, OROVILLE Phone: 5309905566 Owner Name: CARPENTER AARON & HEATHER Description: CONV GAR TO LIVING (470) -Signature of Applicant: Date: 1/9/2017 • r • f Department of Development Services Tim Snellings, Director Pete Calarco, Assistant Director ®Ill 11 Ly j 7 County Center Drive T: 530.538.7601 Buttecounty.net/dds Droville, California 95965 F: 530.538.7785 DEVELOPMENT SERVICES PLAN CHECK SQUARE FOOTAGE VERIFICATION Permit -Number: B17-0041 Owner's Name: CARPENTER AARON & HEATHER Assessor's Parcel Number: 030-063-009 Date of Application: 1/9/2017 Square Footage Verification n At Application: Change To: wing Area 0 Garage Area 0 Covered Area 0 0 C i. 7-"-% C6,0ZBUTTE COUNTY WALL CONSTRUCTION BUILDING DIVISION TABLE R602.3(i)� ROVE® FASTENING SCHEDULE ITEM DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE OF FASTENER °• SPACING AND LOCATION Roof 4-8d box (2'/Z" x 0.113' or 1 Blocking between ceiling joists or rafters to top plate 3-8d common (2'/2"x 0.131'); or 3-1 Od box (3" x 0.128'x; or Toe nail 3-3 " x 0.131 " nails 4-8d box (2'/Z" x 0.113 "); or 2 Ceiling joists to top plate 3-8d common (2'/Z" x 0.131'); or Per joist, toe nail 3-1Od box (3" x 0.128'); or 3-3" x 0.131 "nails Ceiling joist not attached to parallel rafter, laps over 4-1Od box (3"x 0.128'); or 3 partitions [see Sections R802.3.1, R802.3.2 and Table 3-16d common (3'/Z" x 0.162'); or Face nail R802.5.1(9)] 4-3 " x 0.131 " nails Ceiling joist attached to parallel rafter (heel joint) 4 [see Sections R802.3.1 and R802.3.2 and Table Table R802.5.1(9) Face nail R802.5.1(9)] Collar tie to rafter, face nail or 1'/," x 20 ga. ridge strap to 4-10d box (3" x 0.128'); or 5 rafter 3-1 Od common (3" x 0.148'1; or Face nail each rafter 4-3 " x 0.131 " nails 3-16d box'nails (3'/2" x 0.135'); or 3-1 Od common nails (3" x 0.148'); 2 toe nails on one side and 1 toe nail 6 Rafter or roof truss to plate or on opposite side of each rafter, or 4-1Od box (3" x 0.128'); or truss' 4-3" x 0.131 " nails 4-16d (3'/Z" x 0.135'); or 3-10d common (3'/Z" x 0.148'); or 4-1Od box (3" x 0.128'); or Toe nail Roof rafters to ridge, valley or hip rafters or roof rafter 4-3 " x 0.131 " nails 3-16d box 3'/2" x 0:135 "); or to minimum 2" ridge beam g 2-16d common (3'/2" x 0.162'); or 3-10d box (3"x 0.128'); or End nail 3-3 " x 0.131 " nails Wall 16d common (3'/Z" x 0.162') 24" o.c. face nail 8 Stud to stud (not at braced wall panels) l Od box (3 " x 0.128'D; or 3 " x 0.131 " nails 16" o.c. face nail 16d box (3'/Z" x 0.135'); or 9 Stud to stud and abutting studs at intersecting wall corners 3 " x 0.131 " nails 12" o.c. face nail (at braced wall panels) 16d common (3'/Z" x 0.162') 16" o.c. face nail 10 '/2' Built-up header (2" to 2" header withspacer) 16d common (3'/2 ",x 0.162') 16" o.c. each edge face nail 16d box (3'/Z" x 0.135') 12" o.c. each edge face nail 5-8d box (2'/2" x 0.113'); or 11 Continuous header to stud 4-8d common (2'/2" x 0.131'); or Toe nail 4-1Od box (3" x 0.128'D 16d common (3'/Z" x 0.162' 16" o.c. face nail 12 Top plate to top plate 10d box (3" x 0.128"); or 3"x 0.131"nails 12" o.c. face nail 8-16d common (3'/Z" x 0.162'); or Double top plate splice for SDCs A -DZ with seismic 12-16d box (3'/2" x 0.135'); or braced wall line spacing < 25' 12-10d box (3" x 0.128'); or Face nail on each side of end joint 13 12-3 " x 0.131 " nails (minimum 24" lap splice length each side of end joint) Double top plate splice SDCs Do, D,or D2; and braced 12-16d (3'/Z" x 0.135') wall line spacing >_ 25' (continued) 2016 CALIFORNIA RESIDENTIAL CODE P l /- 00�� 1 209 1. WALL CONSTRUCTION TABLE R602.3(1}—continued FASTENING SCHEDULE ITEM DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE OF FASTENER'- ° ` SPACING AND LOCATION 16d common (3'/2" x 0.162') 16" o.c. face nail 14 Bottom plate to joist, rim joist, band joist or � 16d box (3'/," x 0.135'); or blocking (not at braced wall panels) 3" x 0.131 " nails 12" o.c. face nail 3-16d box (3'/2" x 0.135"); or 3 each 16" o.c. face nail 15 Bottom plate joist, rim joist, band joist or 2-16d common (3'/2" x 0.162"); or 2 each 16" o.c. face nail blocking (at braced wall panel) t 4-3 " x 0.131 " nails 4 each 16" o.c. face nail 4-8d box (21/ " x 0.113'); or 3-16d box (3�/2" x 0.135"); or 4-8d common (2'/2" x 0.131'); or Toe nail 4-10d box (3" x 0.128'D; or 16 Top or bottom plate to stud 4-3 " x 0.131 " nails 3-16d box (3'/Z" x 0.135'); or 2-16d common (3'/Z" x 0.162'x; or End nail 3-10d box (3"x 0.128'); or 3-3" x 0.1.31 " nails 3-IOd box (3" x 0.128'); or 17 Top plates, laps at corners and intersections 2-16d common (3'/Z" x 0.162'); or Face nail 3-3 " x 0.131 " nails 3-8d box (2'/2" x 0.113'); or 18 1 "brace to each stud and plate 2-8d common (2'/Z131'); or " x 0. 2-1Od box (3" x 0.128'x; or Face nail 2 staples 1'/4" 3-8d box (2'/Z" x 0.113'); or 19 1 " x 6"sheathing to each bearing 2-8d common (2'/2" x 0.131'); or Face nail 2-10d box (3" x 0.128')• or 2 staples, 1"crown, 16 ga., 1'/4" long 3-8d box (2'/2" x 0.113'); or 3-8d common (2't2" x 0.131'); or 3-10d box (3 " x 0.128'); or 3 staples, 1 " crown, 16 ga., 1'/4" long 20 1 " x 8" and wider sheathing to each bearing Face nail Wider than 1 " x 8"• 4-8d box (2'/z" x 0.113'); or 3-8d common (2'/Z" x 0.131'); or 3-10d box (3" x 0.128'); or 4 staples, 1 " crown, 16 ga., 13/4" long Floor 4-8d box (2'/Z" x 0.113'); or 21 Joist to sill, top plate or girder 3-8d common (2'/," x 0:131'); or " Toe nail 3-10d box (3 x 0.128 ), or 3-3 " x 0.131 " nails 8d box (2'/Z" x 0.113') 4" o.c. toe nail 22 Rim joist, band joist or blocking to sill or top 8d common (2'/Z" x 0.131 "); or plate (roof applications also) 1 O box (3" x 0.128'); or 6" o.c. toe nail 3 " x 0.131 " nails 3-8d box (2'/2" x 0.113'); or 23 1 " x 6" subfloor or less to each joist 2-8d common (2'/2'•' x 0.131'); or Face nail 3-tOd box (3" x 0.128'); or 2 staples, 1 " crown, 16 ga., 13/4" long (continued) 210 2016 CALIFORNIA RESIDENTIAL CODE Z WALL CONSTRUCTION TABLE 602.3(1) FASTENING SCHEDULE—continued ITEM DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE OF FASTENER ° `•° SPACING AND LOCATION Floor 24 2" subfloor to joist or girder 3-16d box (3'/2" x0.135"); or 2-16d common (31/." x 0.162 ) Blind and face nail 25 2" planks (plank & beam—floor & roof) 3-16d box (3'/2" x0.135'); or 2-16d common (31/," x 0.162') At each bearing, face nail 3-16d common (3'/2" x 0.162") 26 Band or rim joist to joist 4-10 box (3" x 0.128'), or 4-3 " x 0.131 " nails; or End nail 4-3" x 14 ga. staples,'/16" crown 20d common (4" x 0.192'); or Nail each layer as follows: 32" o.c. at top and bottom and staggered. 1 O box (3" x 0.128'); or 24" o.c. face nail at top and bottom 27 Built-up girders and beams, 2 -inch lumber 3" x 0.131"nails staggered on opposite sides layers And: 2-20d common (4" x 0.192'); or 3-1Od box (3" x 0.128'); or Face nail at ends and at each splice 3-3 " x 0.131 " nails 4-16d box (3'/2" x 0.135'x; or 28 Ledger strip supporting joists or rafters 3-16d common (3'/2" x 0.162'); or 4-1Od box (3" x 0.128'); or At each joist or rafter, face nail 4-3 " x 0.131 " nails 29 Bridging to joist 2-1Od (3" x 0.128') Each end, toe nail SPACING OF FASTENERS ITEM DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE OF FASTENER", b, Edges Intermediate supports (inches)° (Inches) Wood structural panels, subfloor, roof and Interior wall sheathing to framing and particleboard wall sheathing to framing [see Table R602.3(3) for wood structural panel exterforwall sheathing to wall framing] 30 3/8,,_ '/ 6d common (2", x 0.113') nail (subfloor, wall)' 6 12' 2" 8d common (2'/2" x 0.131') nail (roof) 31 19/32– 1 " 8d common nail (2'/2" x'0.131') 6 12' 32 1'/8"– 11/4" 1 O common (3"x 0.148' nail; or 6 12 8d (2 /2 x 0.131') deformed nail Other wall sheathing° 33 '/2„ structural cellulosic fiberboard 11/2" galvanized roofing nail,'/16" head 3 6 sheathing diameter, or 1 " crown staple 16 ga.; 1'/4" long 34 25/12" structural cellulosic is/4" galvanized roofing nail,'/16" head fiberboard sheathing diameter, or 1 " crown staple 16 ga., 11/4" long 3 6 35 '/2" gypsum sheathing' 11/2 "galvanized roofing nail; staple galvanized, 7 7 11/," long; 1 /4" screws, Type W or S 36 5/8" gypsum sheathing' 15/4"galvanized roofing nail; staple galvanized, 7 7 1 /s long; 15/, ' screws, Type W or S Wood structural panels, combination subfloor underlayment to framing 37 3/ " and less 6d deformed (2" x 0.120') nail; or 6 12 4 8d common (2'/2" x 0.131') nail 38 7/8,, – 1 " 8d common (2'/2" x 0.131') nail; or 6 12 8d deformed (2'/2" x 0.120') nail 39 11/8"– 11/4" 1 O common (3" x 0.148") nail; or 6 12 8d deformed (2'/2" x 0.120') nail For St: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 0.447 m1s; 1 ksi = 6.895 MPa. 2016 CALIFORNIA RESIDENTIAL CODE (continued) 211 WALL CONSTRUCTION . TABLE R602.3(1) --continued FASTENING SCHEDULE a. Nails are smooth -common, box or deformed shanks except where otherwise stated. Nails used for framing and sheathing connections shall have minimum average bending yield strengths as shown: 80 ksi for shank diameter of 0.192 inch (20d common nail), 90 ksi for shank diameters larger than 0.142 inch but not larger than 0.177 inch, and 100 ksi for shank diameters of 0.142 inch or less. b. Staples are 16 gage wire and have a minimum'/16 inch on diameter crown width. c. Nails shall be spaced at not more than 6 inches on center at all supports where spans are 48 inches or greater. d. Four -foot by 8 -foot or 4 -foot by 9 -foot panels shall be applied vertically. e. Spacing of fasteners not included in this table shall be based on Table R602.3(2). f. Where the ultimate design wind speed is 130 mph or less, nails for attaching wood structural panel roof sheathing to gable end wall framing shall be spaced 6 inches on center. Where the ultimate design wind speed is greater than 130 mph, nails for attaching panel roof sheathing to intermediate supports shall be spaced 6 inches on center for minimum 48 -inch distance from ridges, eaves and gable end walls; and 4 inches on center to gable end wall framing. g. Gypsum sheathing shall conform to ASTM C1396 and shall be installed in accordance with GA 253. Fiberboard sheathing shall conform to ASTM 0208. h. Spacing of fasteners on floor sheathing panel edges applies to panel edges supported by framing members and required blocking and at floor perimeters only. Spacing of fasteners on roof sheathing panel edges applies to panel edges supported by framing members and required blocking. Blocking of roof or floor sheathing panel edges perpendicular to the framing members need not be provided except as required by other provisions of this code. Floor perimeter shall be supported by framing members or solid blocking. i. Where a rafter is fastened to an adjacent parallel ceiling joist in accordance with this schedule, provide two toe nails on one side of the rafter and toe nails from the ceiling joist to top plate in accordance with this schedule. The toe nail on the opposite side of the rafter shall not be required. TABLE R602.3.2 SINGLE TOP -PLATE SPLICE CONNECTION DETAILS For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm. 212 2016 CALIFORNIA RESIDENTIAL CODE TOP -PLATE SPLICE LOCATION CONDITION Corners and Intersecting walls Butt Joints In straight walla Splice plate size Minimum nails each side of Joint Splice plate size Minimum nails each side of Joint Structures in SDC A -C; and in SDC 3" x 6" x 0.036" (6) 8d box. 3' x 12" x 0.036" (12) 8d box Do, D, and DZ with braced wall line galvanized steel plate (2tlZ' x 0.113") nails galvanized steel plate (2'/Z" x 0.113") nails spacing less than 25 feet or equivalent or equivalent Structures in SDC Do, DI and D21 3" x 8" by 0:036" (9) 8d box' 3' x 16" x 0.036" (18) 8d box with braced wall line spacing galvanized steel plate (211z , x 0.113") nails galvanized steel plate (2'/Z" x 0.113") nails greater than or equal to 25 feet or equivalent or equivalent For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm. 212 2016 CALIFORNIA RESIDENTIAL CODE 5 6ERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Carpenter Additon Calculation Date/Time: 09:17, Sun, Jan 08, 2017 Calculation Description: Ex HVAC Altered DHW Input File Name: Carpenter Additionxibd16 CFI R -PRF -01 Page 1 of 8 GENERAL INFORMATION 01 Project Name Carpenter Additon 02 Calculation Description Addition 225 ft2 03 Project Location 1658 Creat Dr .r...�...n,e•t-�e++i""yi iii-�cr>' V��.i....•.i:5"L'"'-"� •, , l�...�.�;Of•IV GAG'-TC�,i_iVllJ� (4'C!j,,,,,t_,. 04 City Oroville 05 Standards Version Compliance 2017 06 Zip Code 95965 07 Compliance Manager Version BEMCmpMgr 2016.2.1 (695) 08 Climate Zone CZ11 09 Software Version CBECC-Res 2016.2.1 (868) 10 Building Type Single Family 11 Front Orientation (dog/Cardinal) 0 12 Project Scope Addition and/or Alteration 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (W) 1893 15 Number of Zones 2 16 Slab Area (ft?) 1893 17 Number of Stories 1 18 Addition Cond. Floor Asea 470 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) 470 21 Glazing Percentage (%) 10.1% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building DOES NOT require HERS Ve*rification�,;; 11 �� 'I 1 1 tr 03 This building incorporatesron�e:ior>wmore ore Sp4eVa--Fey at.s res''si howanbelo w U U U '0 0 f� 17 Registration Number. 2t7-Pol0025434A-000-000-0000000-0000 Registration Date�me: 2017 01-oa �7 'fib ILDIV4G ®� Pmyyvider. CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-10032016 695 �ip"R®UeP rtGefierated at: 2017-01-08 09:18:10 A ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 21.83 22.50 -0.67 -3.1% Space Cooling 64.90 59.91 4.99 7.7% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 13.80 13.80 0.00 0.0% Photovoltaic Offset — 0.00 0.00 — Compliance Energy Total 100.53 96.21 4.32 4.3% f� 17 Registration Number. 2t7-Pol0025434A-000-000-0000000-0000 Registration Date�me: 2017 01-oa �7 'fib ILDIV4G ®� Pmyyvider. CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-10032016 695 �ip"R®UeP rtGefierated at: 2017-01-08 09:18:10 A G`ERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Carpenter Additon Calculation Date/Time: 09:17, Sun, Jan 08, 2017 Calculation Description: Ex HVAC Altered DHW Input File Name: Carpenter Addition.ribd16 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Ceiling has high level of insulation • Window overhangs and/or fins • New ductwork added is less than 40 ft. in length CF1 R -PRF -01 Page 2 of 8 HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: —None— Cooling System Verifications: • — None — HVAC Distribution System Verifications: None — Domestic Hot Water System Verifications: • — None — A ENERGY DESIGN RATINGThis is the sum of the annual TDV energy�consumption-for e'nbrgy�use components -included in the performance compliance approach for the Standard Design Building (Energy Budget) and the annual TDV energy co nsumption`for lighting and components. not regulated by Title`24; Part 6'(such i-0.! omestic appl i a nces. a nd consumer electronics) and accounting for the annual TDV energy offset by an on-site renewabie.energy system. 1� 0. Reference' Energy Use Energy Design Rating Margin Percent Improvement Total Energy (kTDV/ft2-yr)* J144.5i CR S it - 140.18 4.33 3.0% ' includes calculated Appliances and Miscellaneous Energy Use (AMEU) BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Carpenter Additon 1893 1 3 2 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 House Conditioned Ex System 1423 8 DHW System 3 Addition Conditioned Ex System 470 8 DHW System 3 Registration Number: 217-Po10025434A-000-000-0000000-0000 Registration Date/Time: 2017-01-08 17:10:50 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-10032016-695 HERS Provider: CaiCERTS inc. Report Generated at: 2017-01-08 09:18:10 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Carpenter Additon Calculation Date/Time: 09:17, Sun, Jan 08, 2017 . Calculation Description: Ex HVAC Altered DHW Input File Name: Carpenter Addition.ribd16 CFIR-PRF-01 Page 3 of 8 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) Status Verified Existing Condition Ex Wall Front House Wall R-19 0 Front 264 65 90 Existing No Ex Wall Left House Wall R-19 90 Left 212 6 90 Existing No Ex Wall Back House Wall R-19 180 Back 436 94.02 90 Existing No Ex Wall Right House Wall R-19 270 Right 256 4 90 Existing No Ceiling (below attic) House Ceiling R-49 1423 Altered N/A Add Wail Left Addition Wall R-19 90 Left 176 0 90 New N/A Add Wall Right Addition Wall R-19 270 Right 132 12 90 New N/A Add Wall Front Addition Wall R-19 0 Front 172 30 90 New NIA Addition Ceiling Addition] j • Ceiling R-49 - 470 New N/A ATTIC 01 ,, 02v °`�;•r`'� 031 � * 04 t t 06 J 07 08 09 10 'Name PIC ns" t�uctionIL Typ �, F ,4Roof Rise ;I Roof-��''q Reflectanc°°eft . Roof' T Emittan Radiant Barrier Cool Roof Status Verified Existing Condition Attic Asphalt Shi gle�l2oof Ventilated - 4 I V ;) eq.1 .t 10:85 =No No Existing No Addtn Attic Asphalt Shingle Roof Y. p Ventilated - 4 w 0.1 .` L 0 85 No No New INo 1 Registration Number. 217-Po10025434A-000-000-0000000-0000 Registration DateMme: 2017-01 -08.17:10:50 HERS Provider. CaiCERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-10032016-695 Report Generated at: 2017-01-08 09:18:10 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Carpenter Additon Calculation Description: Ex HVAC Altered DHW Calculation Date/Time: 09:17, Sun, Jan 08, 2017 Input File Name: Carpenter Addition.ribdl6 CF1 R -PRF -01 Page 4 of 8 WINDOWS 01 02 03 04 05 06 07 08 09 10 11 Name Surface (Orientation -Azimuth) Width(ft) Height (ft) Multiplier Area (W) U -factor SHGC Exterior Shading Status Verified Existing Condition Ex F1 Ex Wall Front (Front -0) 3.0 5.0 1 1 15.0 0.35 0.35 Insect Screen (default) Existing No Ex F2 Ex Wall Front (Front -0) 3.0 5.0 1 c.15.0 0.35 0.35 Insect Screen (default) Existing No Ex F3 Ex Wall Front (Front -0) 3.0 5.0 1 (15.0 0.35 0.35 Insect Screen (default) Existing No Ex L1 Ex Wall Left (Left -90) - - 1 < 6.0 0.35 0.35 Insect Screen (default) Existing No Ex 131 Ex Wall Back (Back -180) 3.0 1 5.0 1 X15.0 0.35 0.35 Insect Screen (default) Existing No Ex 62 Ex Wall Back (Back -180) 3.0 5.0 1 15.0 0.35 0.35 Insect Screen (default) Altered N/A Ex B3 Ex Wall Back (Back -180) 3.0 3.0 1 ( 9.0 0.35 0.35 Insect Screen (default) Existing No Ex 134 Ex Wall Back (Back -180) 3.0 6.7 1 20.0 0.65 , 0.60 Insect Screen (default) Existing No Ex 135 Ex Wall Back (Back -180) 3.0 6.7 1 1 720.0 0.65 0.60 Insect Screen (default) Existing No Ex 136 "`"`;Ex:Wall Back`(Back-180)• - . 3.0r 5.0 1 .15.0 0.35 0.35 Insect Screen (default) Existing No Ex R1 N%'Ex'Wall Right (Right470) - ,..� , :, .�,,,�1y„�_. 3 ,,,44.0 r0.35 0.35 Insect Screen (default) Existing No Add R2 Add Wall Right -(Right -270){ 4r0 I I 3.0L, ),1 11 ��12.0 0.32 0,25'! Insect Screen (default) New N/A Add F4 ` ) ( ° 1 �-r� 1 A"dd:Vllall Front+(Front-0) X15 016.j2 , t0:25� Insect Screen (default) New N/A Add F5 );Add Wail Front.(FfOnt-0) r -g- .�+- i 1 V15a)V.yk .VO.32 jr, 0:25 Insect Screen (default) I New N/A DOORS 01 02 03 04 05 06 Name Side of Building Area (ft2) U -factor Status Verified Existing Condition Entry Ex Wall Front 20.0 0.50 Existing No Registration Number: 217_Po10025434A-000-000-0000000-0000 Registration Dateffime: 2017-01-08 17:10:50 HERS Provider. CaiCERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-10032016.695 Report Generated at: 2017-01-08 09:18:10 ItERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Carpenter Additon Calculation Description: Ex HVAC Altered DHW Calculation Daterrime: 09:17, Sun, Jan 08, 2017 Input File Name: Carpenter Addition.ribd16 CFI R -PRF -01 Page 5 of 8 OVERHANGS AND FINS 01 02 r + ! 03� hq�1 \ f-04 F �) _ 0511 ,� i 1� � � 7� �6._ 07 Construction Name /tel I O Surface Type � �,...r �..r. ;, Construction Type ,. �...•�>.�..�-;+ + � Framing 01 02 03 04 05 06 07 08 09 10 11 12 13 14 0.8 Overhang Existing No Roof Deck: Wood Siding/sheathing/decking Left Fin Attic Roofs Wood Framed Ceiling in. O.C. Right Fin 0.644 Window Left Depth Dist Up Extent Right Extent Flap Ht. Depth Top Up Distl- Bot Up Depth Top Up Dist R Bot Up Ex F1 2 0.5 5.5 5.5 0 0 0 0 0 0 0 0 0 Ex F2 2 0.5 2.5 14 0 0 0 0 0 0 0 0 0 Ex F3 2 0.5 2.5 14 0 0 0 0 0 0 0 0 0 Ex B1 2 0.5 43 8.5 0 0 0 0 0 0 0 0 0 Ex B2 2 0.5 35 16.5 0 0 0 0 0 0 0 0 0 Ex 83 2 0.5 27 24.5 0 0 0 0 0 0 0 0 0 Ex B4 2 A 0.5 19.5 32 0 1 0 0 0 0 0 0 0 0 Ex B5 2 1 0.5 16.5 34.5 0 0 0 0 0 0 0 0 0 Ex B6 2'/ '� 0.5 5.5 46.5 0 0 0 0 0 0 0 0 0 Add R2 ,-� 2' '-0.5 ,, .- 4 "" 8.5 0 0 0 0 0 0 0 0 0 OPAQUE SURFACE CONSTRUCTIONS 01 02 r + ! 03� hq�1 \ f-04 F �) _ 0511 ,� i 1� � � 7� �6._ 07 Construction Name /tel I O Surface Type � �,...r �..r. ;, Construction Type ,. �...•�>.�..�-;+ + � Framing ' 1 ..0- ;w Total Cavity Revalue nW' w Winter Design 4U value Assembly Layers Carpeted Fraction Heated Status Verified Existing Condition Ex Slab House • Cavity/ Frame: no insul. /2x4 Top Chrd 155.5 None 0.8 2x4 Top Chord of Roof Truss @ 24 Existing No Roof Deck: Wood Siding/sheathing/decking Asphalt Shingle Roof Attic Roofs Wood Framed Ceiling in. O.C. none 0.644 Roofing: Light Roof (Asphalt Shingle) No • Inside Finish: Gypsum Board • Cavity/Frame: R -19/2x6 Wall R-19 Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 19 0.072 Exterior Finish: 3 Coat Stucco • Inside Finish: Gypsum Board Ceilings (below 2x4 Bottom Chord of Truss @ 24 Cavity/Frame: R-9.1 /2x4 Bim Chrd Ceiling R-49 attic) Wood Framed Ceiling in. O.C. R49 0.020 Over Ceiling Joists: R-39.9 insul. SLAB FLOORS 01 02 03 04 05 06 07 08 09 Name Zone Area (ftz) Perimeter (ft) Edge Insul. R -value Carpeted Fraction Heated Status Verified Existing Condition Ex Slab House 1423 155.5 None 0.8 No Existing No Slab On Grade Addition 470 60 None 0.8 No New No Registration Number: 217-Po10025434A-000-000-0000000-0000 Registration DateMme: 2017-01-08 17:10:50 HERS Provider: CaiCERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-10032016.695 Report Generated at: 2017-01-08 09:18:10 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Carpenter Additon Calculation Date/Time: 09:17, Sun, Jan 08, 2017 Calculation Description: Ex HVAC Altered DHW Input File Name: Carpenter Addition.ribd16 BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required — CF1 R -PRF -01 Page 6 of 8 WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction N Status Verified Existing Condition DHW System 3 DHW Standard Gas Storage 1 - none - Existing No WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 Name Heater Element Type .rrTank ,---Tank Type--- Number of Units Volume _(gal), Energy Factor or .• Efficiency Input Rating/Pilot Tank Insulation R -value (Int/Ext) Standby Loss I Recovery Eff NEEA Heat Pump Type Tank Location of Ambient Condition Gas Storage Gas Small Storage,f T` X40 n 9.& ;40000-Btu/hr= A n/a Na n/a n/a SPACE CONDITIONING SYSTEMS �,/ /4Z9 i 11 It Iii I ice& I I II M 01 02 %`� 03 r� A 'Z041 U k4 U A::Z 05i V U 06 �'* 'v 07 08 09 Heating System J= #1 ',-Coolin 'S stemX k 9 y 1 ) ,1 Distribution Fan Floor Area Verified Existing Name System Type Name Ducted Name Ducted System System Served Status Condition Ex System Other Heating and Cooling System Ex Furnace Yes Ex Cooling Yes Ducts HVAC Fan 1893 Existing "L No HVAC - HEATING SYSTEMS 01 02 03 Name Type Efficiency Ex Furnace CntHFumace - Fuel -fired central furnace 80 AFUE Registration Number: P17-Po10025434A-000.000-0000000-0000 Registration Date/Time: 2017-01-09 17:10:50 HERS Provider. CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-10032016.695 Report Generated at: 2017-01-08 09:18:10 r CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Carpenter Additon Calculation DatefTime: 09:17, Sun, Jan 08, 2017 Calculation Description: Ex HVAC Altered DHW Input File Name: Carpenter Addition.ribd16 CFI R -PRF -01 Page 7 of 8 HVAC - COOLING SYSTEMS 01 02 03 04 05 06 07 07 08 Efficiency Zonally Controlled Multi -speed Compressor Name System Type EER SEER HERS Verification Ex Cooling SplitAirCond - Split air conditioning system 8.74. 10 No No N/A HVAC - DISTRIBUTION SYSTEMS 01 02 03 1 04 05 06 07 08 09 10 Insulation Supply Duct Return Duct Verified Existing HERS Name Type Duct Leakage R -value Location Location Bypass Duct Status Condition Verification Duds located in attic Existing (not Ducts (Ventilated and specified) A 8.0 Attic Attic None Existing + New No N/A Unventilated) I - I I I I I I IAQ (Indoor Air Quality) FANS 01 -J" '_02 ,.,rw.r». 03 04 05 Name ?;IAQ CFM i y- IAQ-Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 0 Defauit,-., 0 Not Required Registration Number P17-POI0025434A-000-000-0000000-0000 Registration DateTme: 2017-01-08 17:10:50 - CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-10032016-695 HERS Provider. y CaICERTS inc. Report Generated at: 2017-01-08 09:18:10 ? : U V 'u HERS PROVIDER Registration Number P17-POI0025434A-000-000-0000000-0000 Registration DateTme: 2017-01-08 17:10:50 - CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-10032016-695 HERS Provider. y CaICERTS inc. Report Generated at: 2017-01-08 09:18:10 I CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Carpenter Additon Calculation Date/Time: 09:17, Sun, Jan 08, 2017 Calculation Description: Ex HVAC Altered DHW Input File Name: Carpenter Addition.ribd16 CF1 R -PRF -01 Page 8 of 8 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: - Documentation Author Signature: Martin Alvis Company: Signature Date: M & T Energy Analyst 2017-01-08 17:06:02 Address: CEA/HERS Certification Identification (If applicable): P.O. Box 534 City/State/Zip: Phone: Chico, CA 95927 530-990-0030 RESPONSIBLE PERSON'S DECLARATION STATEMENT x I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business`and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. ..�._� documents, 3. The building design features'or• system-desigri features identified on4his Certificate of Compliance are consistent with the information provided on other applicable compliance worksheets, calculations, plans and -specifications submitted -to -the enforcement.agencyfor approval.with:this.building permit application. rt Responsible Designer Name: } .1 I I L J Responsible Designer Sig ature n YC BARRY RUBANOFFL ff� a�q, Company: Date.Signed: " 20 0F1-087:10:50' BARRY RUBANOFF 7 Address: License: PO BOX 1123 n/a City/State/Zip: Phone: Berry Creek, CA 95916 530-589-4102 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number. 217-Po10025434A-000-000-0000000-0000 Registration Date/Time: 2017-01-0817:10:50 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-10032016-695 Report Generated at: 2017-01-08 09:18:10