Loading...
HomeMy WebLinkAboutB17-0078 040-630-008Butte County Department of Development Services r' PLAN CHECK 7 County Center Drive, Oroville, CA 95965 Main Phone (530) 538-7601 Fax (530) 538-7785 DEVELOPMENT SERVICES , FLOOD PLAIN DECLARATION I declare the market value of the proposed construction work under building permit application number: B17-0078 at the location of 9462 VanNeSSAssessor's Parcel Number: 040-630-008 for the construction of an addition and/or remodel consisting of _ $ I y S 1 F, will not equal or exceed the definition of "Substantial Improvement" as defined below. I am aware the building site is located within special flood hazard area zone F . Community Number, Map Panel, and Suffix Dlp007C0S720%ated and may be at risk of flooding although I am not required to. comply with flood plain management criteria. Property Owner: J a m e S Gilmore Address: 9462 VanNess Phone Number: 530- 2 -6331. Print Name: JI r. (G # Ore FORM NO . I DPC-04 BUTTE COUNTY BUILDING DIVISION APPROVED 6 (Z) I -i r �- Signature: - Date: *Substantial Impovement is defined as follows: any reconstruction, rehabilitation, addition, or other proposed new development of a structure, the cost of which equals�'br exceeds fifty (50) percent of the market value of the structure before the "start of construction" of -the improvement. The Substantial Improvement cost is cumulative and includes all improvements that are not listed below as being excepted and that have occurred within the proceeding five years. This term includes structures which have incurred "substantial damage", regardless of the actual repair work performed. The term does not, however, include either: a. Any project for improvement of a structure to correct existing violations or state or local health, sanitary, or safety code specifications which have been identified by the local code enforcement official and which are the minimum necessary to assure safe living conditions; or b. Any alteration of a "historic structure" provided that the alteration will not preclude the structure's continued designation as a "historic structure." Note: If the improvement percentage, cumulative over the last 5 years, equals or exceeds 40% of the market value of the structure before the "start of construction" of the improvement, a certified appraisal shall be required to verify the proposed work will not constitute a substantial improvement. Substantially improved structures shall meet the minimum building standards of the National Flood Insurance Program & Butte County's Flood Plain Ordinance (BCC 26-21) Revised 12.19.2016 Pagel of 2 T � c= :'lkr Substantial Improvement Worksheet for Projects within FEMA Floodplain APN: C4 L-7� 0 ' US C% - Date: EXISTING BUILDING: USE AREA SF -VALUE TOTAL Q6!�, X X i = OW X X = X X = X X = X X = X X = X X Existing Structure Value (ESV): �jS o -O LSD—' PROPOSED ADDITION -REMODEL: USE AREA A SF -VALUE 1 . _z�(0f 6,X 4� b Da �o dv- �ngooA, X . 7 -X pQ = �� ���00 X X X" X = X X X X X x _ REMODEL CONTRACT: Ly Improvement Value (IV): Improvement Percentage = Revised 12.19.2016 IV ESV 1y ti BUTTE COUNTY BUILDING DIVISION rc :APPROVED Page 2 of 2 • biButte County Department of Development Services PLAN CHECK 7 County Center Drive, Oroville, CA 95965 Main Phone (530) 538-7601 Fax (530) 538-7785 FLOOD PLAIN DECLARATION I declare the market value of the proposed construction work under building permit application number: at the location of Assessor's Parcel Number: for the construction of an addition and/or remodel consisting of will not equal or exceed the definition of "Substantial Improvement" as defined below. I am aware the building site is located within special flood hazard area zone Community Number, Map Panel, and Suffix dated , and may be at risk of flooding although I am not required to comply with flood plain management criteria. Property Owner: Address: Phone Number: Print Nam Signature:` Date: FORM NO '" DPC-04 *Substantial Improvement is defined as follows: any reconstruction, rehabilitation, addition, or other proposed new development of a structure, the cost of which equals or exceeds fifty (50) percent of the market value of the structure before the "start of construction" of the improvement. The Substantial Improvement cost is cumulative and includes all improvements that are not listed below as being excepted and that have occurred within the proceeding five years. This term includes structures which have incurred "substantial damage", regardless of the actual repair work performed. The term does not, however, include either: a. Any project for improvement of a structure to correct existing violations or state or local health, sanitary, or safety code specifications which have been identified by the local code enforcement official and which are the minimum necessary to assure safe living conditions; or b. Any alteration of a "historic structure" provided that the alteration will not preclude the structure's continued designation as a "historic structure." Note: If the improvement percentage, cumulative over the last 5 years, equals or exceeds 40% of the market value of the structure before the "start of construction" of the improvement, a certified appraisal shall be required to verify the proposed work will not constitute a substantial improvernent. Substantially improved structures shall meet the minimurn building standards of the National Flood Insurance Program & Butte County's Flood Plain Ordinance (BCC 26-21) Revised 12.19.2016.8 Pagel of2 NOW Butte -County Depa�rtrnent of Development Services - r, PERMIT CENTER 7 County Center Drive, Orovllle, CA 95965 " Main Phone 530.538.7601 faz,530.538.7785 www.buttecounty.net/dds r PLEASE PRINT CLEARLY 4 P-9QP.ER+TY O,W,NER!INFORMWTION L -.l��' Lastpp I ZrY I V First Nalie • Mailing Address City `V Ci - l Stat CA Zip Phone i Fax S 3N Email - . " ,I µ^ 6 U i� t�eD fSU iCi�l Cell n A CONTjK_ACTOR L -.l��' Mailing Addres X • �ntit City State City `V Phone ' . Fax: Email - Cell ' Licer}se No.Class 7 o. PERMIT NO:, ' . • Name —' 60 7� Mailing Addre bw� E City `V htto://gismaps.buttecounty.net/flexviewer/bcd Stan ' - Zg Phhyzne� Zip Fax Email : _G,K86T1ejL Cell Ca C CA State License No. • c PERMIT NO:, ' . • FORM NO —' 60 7� Date' Print Na PERMIT NO:, ' . • FORM NO —' 60 7� DBP -1 ^ N BIN NO: htto://gismaps.buttecounty.net/flexviewer/bcd ®` P,RQJ�EG=TLOrATION� APN es Progeny Addrespt Li 63 . ^ N City ocation mut not be in the city limits of Chico, Gridley, Oroville or Paradi e, htto://gismaps.buttecounty.net/flexviewer/bcd atasearch/index. htmI �,`,, � .�'d110RKEf2�SCOfiRPENS?ATION , '��. Policy Numbe MM Carrier " If hiring other than a fi-c-15rised contractor, a certificate of worker's compensation must be shown at the time of permit issuance structures) are issued by the State. Tell staff if this permit is for a Mobile Home. Click below to see Manufactured Home Alterations and Permit Guidelines at: LENOINGAGE.NCY , Name Mailing Address - City , , State Zip DESGRI-PMN OR SGOPE OFI IIORK ," AW, 4 D . Mobile; Home permits (other than installation, foundation, utilities & non-attached structures) are issued by the State. Tell staff if this permit is for a Mobile Home. Click below to see Manufactured Home Alterations and Permit Guidelines at: Z htt ://vAww.hcd.ca. ov/codes/mh /HCD Phone: 916 255-2501 V Is this a Manufactured/Mobile Home (circle one) Yes I No t ' ON JOB 1�rALlUAyTION. (Ente`-rsval% la6or,'I"rNng $ (� noon cntr�aged ptus mateNals charge) 00U - S ua[e_F®epLDeiafl W Q Living Area:' 6 � Garage: r , • � Open Area: Covered Are O TOTAL SQ: . c 0l Structure Built without permits I G Proposed Change of Occupancy/Use - Note previous/current use below ;F,OR 0,FFICE USE ONI`;YfflV`Pk1 2, WV Zoning: 2 ' Flood Zone: I .. SRA: YES LITNO NPDES YES U, NO ❑ Code Enf: YES 13 NO ❑' Legal Lot: YES ❑ NO ❑ Occupancy Type Construction Pe it Tech: Date`. //3-/,/�,. 'Butte County Department of Public Works DENNIS SCHMIDT, DIRECTOR LAND DEVELOPMENT DIVISION Storm Water Management Program 7 County,Center Drive ` Oioville, CA 95965 (530) 538 7266 Telephone Butte Courit I (530) 538 7171 Fax 1 PUBLIC WORKS National Pollutant Discharge Elimination System (NPDES) Phase II Construction Storm Water Permit and Storm Water Pollution Prevention Plan (SWPPP) Acknowledgment [LESS THAN 1 ACRE1 Reference Number: B17-0078 Date: 1/13/2017 Location: 9462 VAN NESS WAY By: JMD Parcel Number: 040-630-008 Sub Type: ROOM ADDN-FIRST STRY ` Owner Name: GILMORE JAMES H & SIS LYNN Phone: Description: ADDN (816) By'signing below, I the project owner/owners' agent, certify that this project WILL NOT DISTURB 1 acre or more of land and that 1 therefore, do not need to apply for a Construction Siorm Water Permit from the State of California Regional Water Quality Control Board. Phased ...projects that contain multiple site buildouts of less than one acre but when combined with :t I-subsequent'p to more than one acre of disturbed soil will require a Construction Storm Water Pe it fro t ' State of California Regional Water Quality Board. Date 1/13/2017 I . I ' Department of Development Services Tim Snellings, Director Pete Calarco, Assistant Director Beunty 7'County Center Drive T: 530.538.7601 Buttecounty.net/dds RVICEOroville, California 95965 F: 530.538.7785 bEVEIOPMEW SES 1 1. f ° NOTICE TO BUILDERS** Before your building permit can be issued, your plans must be checked for compliance with the California -Building Codes. In addition, your plans are routed to other regulatory entities including but not limited to Planning, Public Works, Environmental Health, and the California Department of Forestry for their clearances and approvals. There are some things youl can do to expedite your permit: Make sure your application is complete. Be responsive to requests from County departments for any additional materials or requirements. The Building Division places its highest priority on processing building permits as quickly as possible and each day'that passes without a complete application adds to processing time. .Every permit issued by the Building Official shall expire and become null and void if the work authorized by such permit is not started or completed within one year from the date of issuance of such permit (per Butte County Code Chapter 26, Article 1, Section 263.1). A permit maybe renewed (for a fee) prior to expiration a maximum of two (2) times, provided construction progress has been documented by the Building Division } during each year during scheduled inspections. No changes may be made in the original plans and specifications for such work. In order to reinstate action on a permit after expiration, the permittee shall pay a new full permit fee and additional plan checking and documentation may be required. Upon completion of work covered by this permit, please contact this office for final inspection. As a reminder to you, it is illegal to occupy this building or any portion of the building for which this permit is issued without a final inspection. EXPIRATION OF PERMIT APPLICATION AND REFUND POLICY" Application for which a permit has not been issued will expire one year after date of application. Refunds may only be made upon written request by the person who originally paid the fees. Refunds for permit applications, if the permit has not issued, but not after 180 days from the date of fee payment. Fees paid at the time of application are for Plan Check and administration. The Plan Check portion of fees is refundable only if the permit is cancelled or withdrawn before any plan checking is done. Building Division costs will be deducted prior to authorizing a refund and a charge to process the refund application will be assessed. The current refund processing fee is $127.00. Refunds on permits (issued) may be requested prior to the expiration of the permit, provided no work has been done pursuant to the permit. An Inspection may be required (and 1 deducted from any refund amount) to determine no work was done. Fee/refund information can be read on-line at http:Hmunicipalcodes.lexisnexis.com/codes/butteco/ "When filed, this application and all supporting material becomes subject to the California Public Records Act. All public information related to this application is subject to public inspection and will be posted on the County's website for electronic access: - Permit Number: B17-0078 Date: 1/13/2017 Parcel Number: 040-630-008 Location: 9462 VAN NESS WAY, DURHAMPhone: Owner Name: GILMORE JAMES H I LYN Description: ADDN (816) Signature of Applicant: • l Date: 1/13/2017 i Department of Development Services Tim Snellings, Director { Pete Calarco, Assistant Director 7 County Center Drive T: 530.538.7601 Buttecounty.net/dds Oroville, California 95965 F: 530.538.7785 1 ' • PERMIT APPLICATION DATA SHEET Reference Number: B17-0078 ! Date: 1/13/2017 Location: 9462 VAN NESS WAY By: JMD Parcel Number: 040-630-008 Sub Type: ROOM ADDN-FIRST STRY Owner Name: GILMORE JAMES H & SIS I Phone: LYNN. ADDN (816) The above permit application has the following Clearances required prior to permit issuance. Please contact each department indicated below regarding specific requirements pertaining to your permit application: YES I SEWER DISTRICTS '❑ Tlliermalito Irrigation District, 410 Grand Avenue, Oroville CA 95965 — 530.533.0740 �❑ LOAPUD, 1960 Elgin Street, Oroville CA 95966 — 530.533.2000 'j. ❑ City of Chico, PO Box 3420, 411 Main Street, Chico CA 95927 — 530.879.6700 PARKS & RECREATION DISTRICTS (form will be available after plans have been reviewed by building department) ❑ 'Chico Area Recreation District, 545 Vallombrosa, Chico CA 95926 — 530.895.4711 1 I] Durham Park & Recreation District, 9447 Midway, Durham CA 95938 — 530.345.1921 0 Feather River Recreaction & Park District, 1875 Feather River Blvd, Oroville CA 95965 — . 530.533.2011 t b Paradise. Parks & Recreation, 6626 Skyway Road, Paradise CA 95969 — 530.872.6393 SCHOOL DISTRICTS (form will be available after plans have been reviewed by building department) ❑ . Biggs Unified School District, 300 B Street, Biggs CA 95917 — 530.868.1281 .❑ Chico Unified School District, 1163 East 7th Street, Chico CA 95926 — 530.891.3006 Durham Unified School District, 4920 Putney Drive, Durham CA 95938 — 530.895.4675 ❑ Gridley School District, 429 Magnolia, Gridley CA 95948 — 530.846.4723 t El Marysville School District, 1919 B Street, Marysville CA 95901 — 530.741.6000 ❑ Oroville Elementary School District, 2795 Yard Street, Oroville CA 95966 — 530.532.3000 ❑ Oroville Union High, 2211 Washington Ave, Oroville CA 95966 — 530.538.2300 Ext: 105 . ❑ Paradise Unified School District, 6696 Clark Road, Paradise CA 95969 — 530.872.6400 OTHER �❑ :Recorded copy of Agricultural Acknowledgment Statement - See Attached Instructions ❑ City of Biggs Planning Department, 3016 Sixth Street Biggs CA 95917 — 530.868.5447 ❑ FEMA Flood Elevation Certificate (required within 48 hours or permit will be placed on hold until received) ❑ Other: **Wheri filed, this application Act.. All public informationre ',County's website for ele I. gtron . Signature of Applicant: )orting material becomes subject to the California Public Records application is subject to public inspection and will be posted on the Date: _1/13/2017 Department of Development Services Tim Snellings, Director Pete Calarco, Assistant Director o a 7 County Center Drive T: 530.538.7601 Buttecounty.net/dds Oroville, California 95965 F: 530.538.7785 DEVEIOPMENT,SERVICES I GIL. ORE JAMES H 8r. SIS LYNN RE:'040-630-008 Permit No: B17-0078 ,:To meet, the requirements of Butte County Code Section 26-12 (available on line at, 'http://rhunicioalcodes.lexisnexis.com/codes/butteco ), one or more of the following may be required before a building permit can be issued for the above referenced project. The construction of curbs, gutters, sidewalks or walkways, public roads, proper access from public i • ' roads, and drainage facilities; Dedication of any necessary rights of way; and f Fo'r,commercial or industrial uses or for multiple living uses having three (3) or more living units per parcel, the construction of an enclosure for containers used to hold solid waste and/or recyclable •;materials for collection. Requirements. prior to issuance of building permit: Submit sufficient information to the Land Development Division of the Public Works Department, 7 County Center Drive, Oroville, CA 95965, that demonstrates compliance with County Code Section 26 If construction plans and/or engineering analysis are required, submit information in duplicate in ' accordance with County Improvement Standards (available on line at http://www.buttecounty.net/publicworks/divisions/landdevelopment/impstd.html ) with a minimum plan checking deposit of $690.40. Important Note: If improvements in compliance with County Code Section 26 12 are required, any construction plans 'and/or engineering analysis must be reviewed and approved by the Land Development Division of the Public Works Department prior to construction of the improvements and the "required improvements must be constructed, bonded, or guaranteed with a deposit of an in lieu fee prior to issuance o this uilding permit. The process can require significant time and must be, completed prio osVnce of the building permit. If you have any qi through Friday, 8: have read and u Signature:, tions,pl � contact the Land Development Division at (530) 538 7266, Monday a.m. to p.m. ;rstand above requirements: Date: 1/13/2017 Butte County Fire Department Fire Prevention Bureau Residential Building Requirements '176 Nelson Ave, Oroville, CA 95965 530.538.7888, 530.538.2105 Fax 530.538.6226 Inspection Line Permit Number: B17-0078 Date: 1/13/2017 Location: 9462 VAN NESS WAY By: JMD Parcel Number: 040-630-008 Sub Type: ROOM ADDN-FIRST STRY Owner Name: GILMORE JAMES H & Phone: `-SIS LYNN ` .,Description; LOT 8 DURHAM GREEN PHASE 2 'To meet the requirements of Government Code section 51182, Butte County Fire department requires a pre -construction inspection to provide the below building and site requirements to the property owner. Your property is located within the Butte County Fire Departments response area and must meet the below. requirements: OP ublic Resources Code 4290 (emergency access, signing/addressing, fuel modification standards) 0 Public Resources Code 4291 (defensible space) ❑'California Fire Code LPG tank protection ❑ Butte County Improvement Standards Requirements prior to scheduling the pre inspection: Full plan submittal to Butte County Development Services Building Division To request an inspection call 530.538.6226; this is Fire Prevention Bureau's recorded inspection line; you will need the information at the top of this page. Inspection request that come through any other phone numbers will cause a delay In processing your permit. For the pre inspections, the property owner or authorized agent (contractor) is required to meet the inspector at the construction site. I have read and understan e e pre inspection requirements. Signature: Date: 1/13/2017 Department of Development Services Tim Snellings, Director Pete Calarco, Assistant Director I 0 7 County Center Drive T: 530.538.7601 Buttecounty.net/dds Doville, California 95965 F: 530.538.7785 JIDEVELOPMENT SERVICES i PLAN CHECK SQUARE FOOTAGE VERIFICATION Permit Number: B17-0078 r ` Owner's Name: GILMORE JAMES H & SIS LYNN Assessor's Parcel Number: 040-630-008 Date of Application: 1/13/2017 ;. Square Footage Verification No Change: %NOTES: Verified By: I• r, . i Confirmed TRAKiT Updated by: (Plan Check Signature) Dater r Date: At Application: Change To: rving Area 816 GGarage Area CCovered 0 Area 0 Open Area 0 No Change: %NOTES: Verified By: I• r, . i Confirmed TRAKiT Updated by: (Plan Check Signature) Dater r Date: Butte County Department of Development Services FORM NO PERMIT CENTER DBP -43 7 County Center Drive, Oroville, CA 95965 Main Phone 530.538.7601 Fax 530.538.7785 www.buttecounty.net/dds IMPORTANT! NOTICE TO PROPERTY OWNER Dear Property Owner: An application for a building permit has been subn�y�tec� ift ouy r nape�listin yourself as tly�,l n,�l� builder of the property improvements specified al j (����v /JUI�J� We are providing you with an Owner -Builder Acknowledgment and Information Verification Form to make you aware of your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owner, obtain the prior approval of the permitting authority. OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION DIRECTIONS: Read and initial each statement below to signify that you understand or verify this information. oG1. 1 understand a frequent practice of unlicensed persons is to have the property owner an "O.wner-Builder" building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance coverage for injuries to workers on my property. W2. 1 understand building permits are not required to be signed by property owners unless they are responsible for the construction and are not hiring a licensed Contractor to assume this esponsibility. 3. I understand as an "Owner -Builder" I am the responsible party of record on the permit. I understand that I may protect myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my own. 44. 1 understand Contractors are required by law to be licensed and bonded in California and tist their license numbers on permits and contracts. 5. 1 understand if I employ or otherwise engage any persons, other than California licensed ntractors, and the total value of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employe'r" understate and federal law. . I understand if I am considered an "employer" under state and federal law, I must t er with the state and federal government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious 4dblcial risk. 7. 1 understand under California Contractors' State License Law, an Owner -Builder who s si ngle-familyy residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building Contractor. Page 1 of 2 Revised 7.20.2015 8. I understand as an Owner -Builder if I sell the property for which this permit is issued, I m be held liable for any financial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the workmanship or materials. I understand I may obtain more information regarding my obligations as an "employer" iroete Internal Revenue Service, the United States Small Business Administration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1-800- 321-CSLB (2752) or www.6sib.ca.gov for more information about licensed contractors. *0. I am aware of and consent to an Owner -Builder building permit applied for in my name, anunderstand that I am the party legally an financially esponsible for proposed construction activity at the following address: Qj Lt _I Ati 1. I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all applicable laws and requirements that govern Owner - Builders as well as employers. 12. I agree to notify the issuer of this form immediately of any additions, deletions, or es to any of the information I have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner -Builder and wish to hire Contractors, you willbe responsible for verifying whether or not those Contractors are properly licensed and the status of their workers' compensation insurance coverage. Before a. building permit can be issued, this property owner and returned to the agency of the property owner's driver's license or '. the agency is required to be presented vh signature. Signature of property owner: Frn must be completed and signed by the sponsible for issuing the permit. Note: A copy aarization, or other verification acceptable to permit is issued to verify the property owner's Date: Note: The following Authorization1s rm is required to be completed by the property owner only when designating an agent of the p operty owner to apply for a construction permit for the Owner -Builder. AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner -Builder Permit for my project. Scope of Construction Project (or Description of Work): Project Location or Address: Name of Authorized Agent: Address of Authorized Agent: Tel No: I declare under penalty of perjury that 1 am the property owner for the address listed above and I personally filled out the above information and certify its accuracy. Note: A copy of the owner's driver's license, form notarization, or other verification acceptable to the agency is required to be presented when the permit is issued to verify the property owner's signature. Property Owner's Signature: Revised 7.20.2015 Page 2 ort Date: rrF�� J� `'✓CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Gilmore Addition Calculation Description: Compliance Calculation Date/Time: 15:08, Fri, May 19, 2017 Input File Name: Gilmore Addition w. QII and exist. WH.ribdl6 CFI R -PRF -01 gUTE Page 1 of 8 COUNTY GENERAL INFORMATION ELOPMENT SERVICES fi 01 Project Name Gilmore Addition (REVIEWED FOR _ DEVELOPMENT 02 Calculation Description Addition GODE UUMPLIAMCC: Standard Design SERVICES 03 Project Location 9462 Van Ness Way -Lj_-I 21.57 20.11 04 City Chico, CA 05 Standards Version Compliance 2017 06 Zip Code 95938 07 Compliance Manager Version BEMCmpMgr 2016.2.1 (695) 08 Climate Zone CZ11 09 Software Version CBECC-Res 2016.2.1 (868) 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 175 12 Project Scope Newly Constructed (Addition Alone) 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 826 15 Number of Zones 1 16 Slab Area (ft2) 0 17 Number of Stories 1 18 Addition Cond. Floor Area 826 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) 0 21 Glazing Percentage (%) 28.1% ADDITION ALONE PROJECT ANALYSIS PARAMETERS - r , 01 "3 02.1!f �f_ �i 1 t(r. 03 ,.. 04 OS 06 Existing Area (excl. new addition) ft2 ( Addition Area -(6X& ezisting)ft2--' 1'' J ITOTA"REA k1 1IExisting Bedrooms Addition Bedrooms Total Bedrooms 3432 �,L' 82fi -'-�` t - u u tt C'425'81/ JW a 14 %4'3} Q 0 3 COMPLIANCE RESULTS , # ' ` } '' ` * K V t •..+ s i 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CECapproved HERS provider. 03 This building incorporates one or more Special Features shown below Registration Number: 217-P010025642C-000-000-0000000-0000 Registration Date/Time: 2017-05-19 15:12:24 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 . HERS Provider: CaICERTS inc. Report Generated at: 2017-05-19 15:09:04 ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 21.57 20.11 1.46 6.8% Space Cooling 50.46 50.57 -0.11 -0.2% IAQ Ventilation 0.00 0.00 0.00 0.0% Water Heating 24.36 24.36 0.00 0.0% Photovoltaic Offset -- 0.00 0.00 — Compliance Energy Total 96.39 95.04 1.35 1.4% Registration Number: 217-P010025642C-000-000-0000000-0000 Registration Date/Time: 2017-05-19 15:12:24 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 . HERS Provider: CaICERTS inc. Report Generated at: 2017-05-19 15:09:04 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Gilmore Addition Calculation Description: Compliance Calculation Date/Time: 15:08, Fri, May 19, 2017 Input File Name: Gilmore Addition w. QII and exist. WH.ribd16 CF1R-PRF-01 Page 2 of 8 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Insulation below roof deck • Window overhangs and/or fins HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High quality insulation installation (QII) Cooling System Verifications: • Minimum Airflow • Verified SEER • Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing Domestic Hot Water System Verifications: -- None -- BUILDING - FEATURES INFORMATION _ Y , Y 01 02 f t 03„ i t t .„ 04 05 ^� 06 07 Project Name Conditioned FloorArea (ft2) - Number of;Dwelling '`Z -Units � g ►— Number of Bedrooms .Number of Zones"'- 0 Number of Ventilation ' Cooling Systems Number of Water Heating Systems Gilmore Addition 826 1 'Q; i. � V U! L 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Conditioned Conditioned HVAC System 1 826 10 ;f• Registration Number: 217-Po10025642C-000-000-0000000-0000 Registration Date/Time: 2017-05-19 15:12:24 HERS Provider: CaICERTS inc. ,; CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 Report Generated at: 2017-05-19 15:09:04 F—ra CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Gilmore Addition Calculation Date/Time: 15:08, Fri, May 19, 2017 Calculation Description: Compliance Input File Name: Gilmore Addition w. QII and exist. WH.ribdl6 CF1R-PRF-01 Page 3 of 8 OPAQUE SURFACES 01 02 03 04 05 e z '' ". ^ � 06 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window & Door Area (ft) Tilt (deg) Fwall Conditioned R23 BIB Wall 175 Front 200 12 90 Bwall Conditioned R23 BIB Wall 355 Back 200 75 90 Rwall Conditioned R23 BIB Wall 85 Right 547 96 90 Lwall Conditioned R23 BIB Wall 265 Left 197 48 90 Ceiling (below attic) 1 Conditioned R38 Ceiling below attic 826 Floor Over Crawlspace Conditioned R19 2x6 FlrOvrCrawl 826 OPAQUE SURFACES - Cathedral Ceilings 01 02 03 04 05 e z '' ". ^ � 06 07 08 09 10 11 Name Zone Type Orientatio n Area (ft) Skylight Area (ft2) Roof Rise (x in 12) Roof Pitch Roof Tilt (deg) Roof Reflectance Roof . Emittance Framing Factor Skylt Ceiling Conditioned R38 Cathedral Ceiling Front 1 1 6 0.5 26.57 0.1 0.85 0.07' ATTIC elp�it- 01 02'"0' e z '' ". ^ � y" " x *' 04'' � 05' 's w '� � 06 07 08 Name Construction t Type " ',;� 1116of Rise"' l oof"Reflectane°, '-Roof Emittance Radiant Barrier Cool Roof Attic Asphalt Roof R19 Ventilated 6 0.1 0.85 No No Registration Number: 217-P010025642C-000-000-0000000-0000 Registration Dateffime: 2017-05-19 15:12:24 HERS Provider: CaICERTS Inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 Report Generated at: 2017-05-19 15:09:04 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Gilmore Addition Calculation Date/Time: 15:08, Fri, May 19, 2017 Calculation Description: Compliance Input File Name: Gilmore Addition w. QII and exist. WH.ribd16 CF1 R -PRF -01 Page 4 of 8 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Area Multiplier (ft2) U -factor SHGC Exterior Shading 3040 SH Window Fwall (Front -175) 3.0 4.0 1 12.0 0.31 0.21 Insect Screen (default) (5) 2660 SH Window Bwall (Back -355) 2.5 6.0 5 75.0 0.31 1 0.21 Insect Screen (default) (4) 2660 SH Window Rwall (Right -85) 2.5 6.0 4 60.0 0.31 0.21 Insect Screen (default) 2040 SH (master) Window Rwall (Right -85) 2.0 4.0 1 8.0 0.31 0.21 Insect Screen (default) 2040 SH (master) -2 Window Rwall (Right -85) 2.0 4.0 1 8.0 0.31 0.21 Insect Screen (default) 2040 SH (toilet) Window Rwall (Right -85) 2.0 4.0 1 8.0 0.31 0.21 Insect Screen (default) 6020 FX Window Rwall (Right -85) 6.0 2.0 1 12.0 0.31 0.21 Insect Screen (default) French Doors Window Lwall (Left -265) 6.0 8.0 1 48.0 0.32 0.28 Insect Screen (default) (2) tube skylts Skylight Skylt Ceiling (Front -175) 30 0.5 0 2 1.0 0.40 0.27 12 OVERHANGS AND FINS 01 02 03 04 05 _06_ 07 08 09 10 11 12 13 14 ('Overhang, I i I_ 1 ( JJ' i j Iw LeftFin\ Right Fin Window Depth Dist Up Lefi Extent Extent Flap Ht. Depth t7Top Up Distt Bot Up Depth Top Up Dist R Bot Up 3040 SH 1 ,`^ 2, t'-`20 t K10 [0.5 1-11 CO V 1 0_�; t 011 0 0 0 0 0 (5) 2660 SH 1 5 4.5 4.5 0 0 0 0 0 0 0 0 0 (4) 2660 SH 1.2 2 8.5 3.5 0.5 0 0 0 0 0 0 0 0 2040 SH (master) 0 0 0 0 0 0 0 0 0 7.5 5 2 0 2040 SH (master) -2 0 0 0 0 0 0 0 0 0 7.5 5 10.5 0 2040 SH (toilet) 0 0 0 0 0 0 0 0 0 7.5 3 26.5 0 6020 FX 0 0 0 0 0 0 0 0 0 7.5 3 18 0 French Doors 1 2 3.5 30 0.5 0 0 0 0 40 12 11.2 0 Registration Number: 217-P010025642C-000-000-0000000-0000 CA Building Energy Efficiency Standards - 2016 Residential Compliance r� Registration DateMme: 2017-05-19 15:12:24 Report Version - CF1 R-05092017-695 HERS Provider: CaICERTS inc. Report Generated at: 2017-05-19 15:09:04 CeRTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Gilmore Addition Calculation Date/Time: 15:08, Fri, May 19, 2017 Calculation Description: Compliance Input File Name: Gilmore Addition w. QII and exist. WH.ribd16 CF1R-PRF-01 Page 5 of 8 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Building Envelope Air Leakage CFM50 Required Not Required Not Required — Total Cavity Winter Design - Construction Name Surface Type Construction Type Framing R -value U -value Assembly Layers Tank Location or Ambient Condition (e) 50 Gal. Tank WH Gas Small Storage 1 50 • Cavity / Frame: R-19 12x8 40,000 Btu/hr R-0 n/a n/a n/a • Roof Deck: Wood Siding/sheathing/decking Asphalt Roof R19 Attic Roofs Wood Framed Ceiling 2x8 @ 24 in. O.C. R 19 0.053 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R -18.8/2x8 R38 Ceiling below attic attic) Wood Framed Ceiling 2x8 @ 16 in. O.C. R 38 0.026 Over Ceiling Joists: R-19.1 insul. • Inside Finish: Gypsum Board • Cavity / Frame: R-38 12x12 • Roof Deck: Wood Siding/sheathing/decking R38 Cathedral Ceiling Cathedral Ceilings Wood Framed Ceiling 2x12 @ 24 in. O.C. R 38 0.029 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity / Frame: R-23 / 2x6 • Sheathing / Insulation: Wood R23 BIB Wall" Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 23 0.063 Siding/sheathing/decking Floors Over , • Floor Surface: Carpeted Floor Deck: Wood Siding/sheathing/decking R19 2x6 FlrOvrCrawl Crawlspace Wood Framed Floo 2x6 @ 16 in O:- 1- R 19� 49 1 Cavity/Frame: R -19/2x6 BUILDING ENVELOPE - HERS VERIFICATION �,~r7 -`-�' �'"�''' '`" ''"" `" ' ' `' �` � u 4J " 01 +rl C x"02 #.- tA fa '1 (03 tt 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required — WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) Existing DHW System DHW Standard (e) 50 Gal. Tank WH (1) 1 n/a WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 Name Heater Element Type Tank Type Number of Units Tank Volume (gal) Energy Factor or Efficiency Input Rating/Pilot Tank Insulation R -value (Int/Ext) Standby Loss I Recovery Eff NEEA Heat Pump Type Tank Location or Ambient Condition (e) 50 Gal. Tank WH Gas Small Storage 1 50 0.62 EF 40,000 Btu/hr R-0 n/a n/a n/a Registration Number: 217-Po10025642C-000-000-0000000-0000 Registration DateMme: 2017-05-19 15:12:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 Report Generated at: 2017-05-19 15:09:04 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Gilmore Addition Calculation Date/Time: 15:08, Fri, May 19, 2017 Calculation Description: Compliance Input File Name: Gilmore Addition w. QII and exist. WH.ribd16 CFI R -PRF -01 Page 6 of 8 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVAC System 1 Other Heating and Cooling System Furn 95 15 SEER - 12.44 EER HVAC Fan 1 Attic R-6 HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Efficiency Furn 95 CntrlFurnace 1 95 AFUE HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 Name System Type Number of Units Efficiency EER SEER Zonally Controlled Compressor Type HERS Verification 15 SEER - 12.44 EER SplitAirCond 1 12.44 15 Not Zonal Single Speed 15 SEER - 12.44 EER -hers -cool HVAC COOLING - HERS VERIFICATION[', 01 01 02 '.—� �u_j L `-- t_ 03� !/ fl 04 t, �: �` t} 05 06 Name .�� Verified Airflow R< R Ic) -Airflow Target Y F Verified EER _ Verified SEER Verified Refrigerant Charge 15 SEER - 12.44 EER -hers -cool Required 350 Not Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R -value Duct Location Bypass Duct HERS Verification Attic R-6 DuctsAttic Sealed and tested 6 Attic None Attic R -6 -hers -dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Attic R -6 -hers -dist Required 5.0 Not Required Not Required Not Required Not Required — Registration Number: 217-P010025642C-000-000-0000000-0000 CA Building Energy Efficiency Standards - 2016 Residential Compliance Registration Date/Time: 2017-05-19 15:12:24 Report Version - CF1R-05092017-695 HERS Provider: CaICERTS inc. Report Generated at: 2017-05-19 15:09:04 'Ct12TIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Gilmore Addition Calculation Date/Time: 15:08, Fri, May 19, 2017 Calculation Description: Compliance Input File Name: Gilmore Addition w. QII and exist. WH.ribd16 CFI R -PRF -01 Page 7 of 8 HVAC -FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1 -hers -fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1 -hers -fan Required 0.58 Et n co H E R S F!" R 0 V I S E R Registration Number: 217-P010025642C-000-000-0000000-0000 Registration Dateffime: 2017-05-19 15:12:24 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 Report Generated at: 2017-05-19 15:09:04 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Gilmore Addition Calculation Description: Compliance Calculation Date/Time: 15:08, Fri, May 19, 2017 Input File Name: Gilmore Addition w. QII and exist. WH.ribd16 CF1 R -PRF -01 Page 8 of 8 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Greg Peitz Company: Signature Date: Gregory A. Peitz Architecture 2017-05-19 15:12:24 Address: CEA/HERS Certification Identification (If applicable): 383 Rio Lindo Ave City/State/Zip: Phone: Chico, CA 95926 530-894-5719 RESPONSIBLE PERSON'S DECLARATION STATEMENT " I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the 'energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. L 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to.,the enforcement agency,for approval,with this building permit application. Responsible Designer Name: Responsible Designer Signature:_ c�r�LL 1 111 C Greg PeitzL l > j i an Company: R P DZ-{Si}n }. 1� I L.. RGregory 15:12:24 A. Peitz Architecture 2017-05-19 Address: License: 383 Rio Lindo Ave C21283 City/State/Zip: Phone: Chico, CA 95926 530-894-5719 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 217-P010025642C-000-000-0000000-0000 Registration Date/Time: 2017-05-1915:12:24 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-05092017-695 VA 0 Easy to Verify at CaICERTS.com HERS Provider: CaICERTS inc. Report Generated at: 2017-05-19 15:09:04 1 GREG0RY� A. VEITZ a , AR.0HIT E.CT 383 Rio Lindo Ave. Chico, CA. 95926 (530) 894-5719 =N1 q f,.•u ,rug I� 4 '' :Vi`µ q 3 Y Structural Calculations for:. PERMIT k BUT? COUNTY DEVELOPMENT SERVICES REVIEWED FOR CODEC (MPLIANCE DATE i� r-t—� BY— ARC �. * No. C2128 is R 1 rLE CJDPY JAStructural\Design Data - Residential.doc DESIGN DATA Code used: 2013 California Building Code Floor loading: Live loads: Uninhabitable attics w/o storage: 10psf Uninhabitable attics w/ limited storage: 20psf Habitable attics and sleeping areas: 30psf All others except balconies and decks: 40psf Dead load -10lbs/square foot Roof loading: Live loads: 20lbs/SF Dead loads: Typical roof -14 lbs/SF Comp roof Wind loading: Basic 3 -second gust wind speed (mph) 110 Wind importance factor, 1 1.00 Wind exposure category C , Internal pressure coefficient, GCpi +/-0.18 Seismic: Seismic importance factor, 1 1.00 Mapped spectral response acceleration; Ss 0.70 Si 0.25 Site class D Design spectral response coefficients; SDS 0.579 SDI 0.317 Seismic design category D Basic seismic -force -resisting system(s) Beaitng wail system - plywood shearwalls Seismic response coefficients), Cs 0.089 Response modification factor(s), R 6.5 Analysis procedure; Equivalent lateral force procedure 2 WIND ANAI YSIS Simplified Envelope Procedure Per ASCE 7-10. Chanter 28. 1. Risk category 2 (table 1.5-1) 2. Basic wind speed: 110 mph (figure 26.5-1A) 3. Exposure: C (section 26.7) 4. Kzt = 1.0 (section 26.8) 5. X = 1.21 (figure 28.6-1) 6. Roof .slopes: 26.57° (6/12) 7. Mean roof height: 15 ft. PS = k Kzt POO (eq. 28.6-1) Wind Pressures Roof internal zone: (7.80 psf) (.6) = 4.68 psf Roof end zone: (8.87 psf) (.6) = 5.33 psf [(2)(4.68psf) + (5.33psf)] / 3 = 4.91 psf average overall wind pressure Wall internal zone: (20.98 psf) (.6) = 12.59 psf Wall end zone: (28.22 psf) (.6) = 16.93 psf [(2)(12.59psf) + (16.93psf)] / 1= 14.04 psf average overall wind pressure 1 � 1 a F . �a 707 000 IA 3 I �� Q 1-1( LINE �(o G)`c'WALLS= SHEARWALLS 3/8" GDX ply. w/ 8d'5 .@ (0 r ,12 o.c. ❑ 5 coat plaster ❑ ( ) gyp. bd. w/ AT ALL 5UPPORT5, BLOOKED ANCHOR BOLTS GBG specified Y2" (P a.b.'s @ 6-0" O.C. w/ min. (2) a.b.'s per wall is adequate ❑ Y2" (P anchor bolts ® O.C. ❑ RBC's .a O.C. rM A55's @ (.l O.C. ❑ NONE RF-a"D OVERTURNING ❑ No holdown's recL'd ❑ 0516 Ho Iddown Straps to Rim Joist be low ❑ Portal f=rame W "Simpson" 5T6224 straps from 4x post to continous header. 1-1DU2, 55T516 @ Single. pour, 55TB20 @ 2 Pour ❑ HDU4, 55T520 @ Single pour, 55TB24 @ 2 Pour COLLECTOR / CHORD ❑ ( ) 16d's per top g splice, ❑ OS16 strap splices ❑ 5T6224 strap splices ❑ Drag Truss Butte County Department of Development Services TIM SNELLINGS, DIRECTOR I PETE CALARCO, ASSISTANT DIRECTOR . I 7 County Center Drive Oroville, CA 95965 530.538.7601 Office 530.538.7785 Fax www.buttecounty.net www.buttegeneralplan.net March 6, 2017 _ James Gilmore L P.O. Box 6039 Chico, CA 95927 Assessor Parcel Number: 040-630-008 Building Permit Number: B17-0078 Plan Check #1 Description: Residential Addition & Remodel Occupancy Classification: R-3 - Construction Type: V -B Stories: One Fire Sprinklers: No Building Total Area:. @ 816 sf Covered Area: 0 sf Flood Zone: AE per 06007CO520E F.I.R.M. dated January 6, 2011 Thank you for submitting permits for your building project. The permit documents have been reviewed and comments are listed below. Please respond in writing to each comment. Complete and clear responses will expedite the re -check and approval of this project. Please provide two revised plan sets with your response. • NON-STRUCTURAL COMMENTS: Amend the plans to indicate that glazing in the following locations to be tempered. C.R.C. Section R308.4. A. In all fixed and operable panels of swinging, sliding and bifold doors.C.R.C. Section R308.4.1. B. In an individual fixed or operable panel adjacent to a door where the where the bottom edge of the glazing is less than 60 inches above the floor or walking surface and it meets either of the ' following: C.R.C. Section 308.4.2 1. The glazing is within 24 inches of either side of the door in the plane of the door in a closed position. 2. The glazing in on a wall perpendicular to the plane of the door in a closed position and within 24 inches of the hinge side of an in -swinging door. C. Glazing in walls, enclosures or fences containing or facing hot tubs, whirlpools, saunas, steam room, bathtubs and showers, and indoor or outdoor swimming pools where the bottom exposed edge of the glazing is less than 60 inches, measured vertically above the standing or walking surface. C.R.C. Section R308.4.5 5ce •�(odr PL& „� • C1 Show the location of the underfloor access. L, Y .? Girders shall be 12" from earth or PT. Joists shall be 18" from earth or PT. Clarify what the new deck decking is. Nte: when exposed to weather it shall be PT or decay resistant wood. 5 c t no/ -e o-, 4v-.ol- l •,• 1 5,1..f. 4q. On Sheet 4 there are references to 3/5 and 2/5, but those details are not shown on sheet 5. Please provide. 5-te swr. 5, Provide a note on the plans that approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into the wall cavity or penetration of water to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. Fluid -applied membranes used as flashing in exterior walls shall comply with AAMA 714. The flashing shall extend to the surface of the exterior wall finish: C.R.C. Section R703.4. rj'ce v�oo4 p t oai t 5 j, i, , 4f Specify all lighting shall be high efficacy per 2016 Energy Code. 5ct rL a �-r etA -ele-e,p la •1, Receptacles shall be installed so that no point measured horizontally along the floor line in any wall space is more than 6 -feet from a receptacle. Any wall space 2 -feet or more in width and unbroken along the floor line by doorways and similar openings shall have a receptacle. 2016 CEC Art. 210.52 (A). By fireplace wall and exercise room. 5<e Electrical panel shall have all circuits labeled. CEC 408.3(F) K5 c -f- e,( e.c,. rt a St,+' 5 , I n, ok. Please list on the cover sheet all Energy requirements for the "Special Feature" and HERS Verification. California Energy Commission, Certificate of Compliance, form CF -1R. }5 << f 1 11. Include the new 3040 front wall window in the energy report. 5 cc ai�� A -q e LAe,- CeLte Please submit a 2016 CalGree Code) Residenti11 Mandatory Measures Check list. Please provide a Cgpstruction Waste Management form. 2016 CalGreen Section 4.408. 0 0W er, STRUCTURAL COMMENTS: A Provide ,foundation details 1/5, 2/5, and 3/5 as referenced on the foundation plan lb Sh'h 5. Please revise building section B-2 to show the girders and piers under the bearing walls. The foundation plan shows two rows of girders under the exercise room but section detail A-2 shows three. Please revise to match. 5 c e n v S eC( .57e c H0-1 _ Please clarify where detail 3/4 occurs. It appears the references to details 1/4 and 3/4 on the roof plan may be reversed. S to rev : S-e-ol v -C-- C4 pt A r', S! •-^F . �. FLOOD ZONE COMMENTS: CheSu bstantial Improvement Worksheet submitted is incomplete. Please revise the Substantial Improvement orksheet to show the value of all proposed improvements to the house and show the improvement percentage. See C&CLc k e c� . The Department of Development Services is currently open to the public from 8:00 am to 3:00 pm. If you wish to discuss these plan check comments, please call during our business hours or contact us by e-mail at the address below. Permit status can be tracked by logging onto ham://www.buttecounty.net/dds//www.buttecounty.net/dds and clicking Building Permits Status.