PROJECT INFORMATION:
A.P.# 041-470-104 4
ORIGINAL CONSTRUCTION BLDG. PERMIT # 94-1833
PERMITTING FOR UNAPPROVED CONSTRUCTION
BLDG. PERMIT # B17-0304
OWNER: MR. +MRS. PETER SCHRADER
PHONE #: 530
CONSTRUCTION TYPE: VB
OCCUPANCY: R -3 -SINGLE FAMILY (2)
FIRE SPRWKLERED: YES
BUILDING AREA: ORIGINAL LIVING AREA, 2ND
FLOOR: 1350 S.F.
BUILDING AREA: CONVERTED GARAGE: 886 S.F.
PROJECT SCOPE: ( )
THE OWNER CONVERTED THE GROUND
FLOOR SPACE ORIGINALLY A
GARAGE/SHOP TO A LIVING AREA,
BATHROOM AND BEDROOM.
THE PROJECT HAS AN ARCHITECTURAL
COMPONENT, TO DOCUMENT THE
CONSTRUCTION DONE WITHOUT A
BUILDING PERMIT. THEN CORRECT
DEFICIENCIES IDENTIFIED BY BUTTE
COUNTY BUILDING DEPARTMENT PLAN
CHECK B17-0304, AS WELL AS ISSUES
IDENTIFIED BY THE ARCHITECT
DURING THE DOCUMENTATION
PROCESS.
BUTTE
COUNTY
I
K
`APR 13 2017
DEVELOPMENT
SERVICES
L
Sheet Title:
NorthStar expressly reserves Is common law copyright and other properly
rights for all ideas, provisions and plans represented of indicated by these
Name
Scale:
drawings, including the principles of design. These plans are not to be
reproduced, nlianged, copied or loaned in any form or matter whatsoever,
nor are they to be assigned to any third party without the expressed
Status:
—
written consent of NorthStar. They are also not to be used In any manner
that may constitute a detriment di" or Indirectly to NorthStar. .
0�:e
LEC
Acceptance of these drawings is an agreement to these terms.
LEC
r
a -J
'^
W
Project No. 17-067
a a
(\i
LO
A
z
r
�
O
F r lmm�U
0
H �
)
U
0
�
W
NO
O
C
�
U
C
c
Z
C
al)
U
�
G
U a cr)70
0
4v0
_
+a
W
H
CO
C)0
>
o
Co(C)-J
2
rn
7
U
00
Z
^
Q
o
cr
L0
Z
z
O
U)
r
raOU)
C
T
T
T
K
`APR 13 2017
DEVELOPMENT
SERVICES
L
Sheet Title:
NorthStar expressly reserves Is common law copyright and other properly
rights for all ideas, provisions and plans represented of indicated by these
Name
Scale:
drawings, including the principles of design. These plans are not to be
reproduced, nlianged, copied or loaned in any form or matter whatsoever,
nor are they to be assigned to any third party without the expressed
Status:
—
written consent of NorthStar. They are also not to be used In any manner
that may constitute a detriment di" or Indirectly to NorthStar. .
Drawn By:
LEC
Acceptance of these drawings is an agreement to these terms.
LEC
Date Issued:
April 2017
Project No. 17-067
a a
A
z
F
O
H �
�
W
W �
U �
W
c
Z
O
G
U a cr)70
Lr)
Cd
�
_
+a
H
0 O
K
`APR 13 2017
DEVELOPMENT
SERVICES
L
Sheet Title:
Sheet
Name
Scale:
1/32" = 1'-0"
Status:
CONSTRUCTION DOCUMENTS
Drawn By:
LEC
Checked By:
LEC
Date Issued:
April 2017
Project No. 17-067
Sheet Na.
A
- l
A
B
C
IC
E
F
G
H
K
0
_,
0
N
64
(n
d § L
Qz
o�
a rTl
1
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
15
iA-
" * 4A
Existing Ceiling Exhaust
------ Fan m
110 cf
-------1------------ -------------------- ----
j1 u i LPG -- HVAC Supply I I
II II I I W/H Register I I
II II I I S I
11 I I
I
I
j11 II I I Existing Surface Mtd. 22
Fluorescent Fixture
I
12/13 _ I
SD/CO i I Existing Gyp. Bd. Ceilingl at I
B . Ceilin at
1 1 Existing Gy d g
+8'-0"; 2x6 Ceiling Joist
I t t +' Joists 4 I
I 8-0" 2x6 Bilin Jofs s
I rt 9
I
of
HVAC�u
7V at 16" o.c. I
1 I I ,_, PP Y Register at 16" o.c. I I
I I I I I
I all I Mounted Clg. Fan an Ig
1M
1 I I / SD/C J
I
I
I
22 V ni y Light C12/13 I I
I
O1
1 � 1 Surface Mtd. 24 '
1j
I 1 - ____� Light Fixture
I I Laundry under Stair - approved
i I I I
I Permit # 94-1833, R-3 Revision; I 1 I HVACupply
10.19.94 I I 1 Regjstgr
@ F.S. I I I
S
I I I I
I I
I
Sylrface Mtd. I j
r � I-Thti Fixture
II II
II II I 1 1 12/1 I I I I
II II O1 L----------1 LD
e — j I
v I 1 1 shall be ha wired - See S11 ec Existing suspended wood panel
II II j below I ceiling at +8' ab. floor, panels
EI I I I I removable
1 n I I 0-
T I N I I I
1 to I I 65 I I I
> I
OU 1 I o
CL
i-iI b I I
HVAC Sc y Han ging Ligh 0 I H �Cupply
1 I ICU
Register, Fxture R istdlr
1 I I c c
I I 1 rn- 1
00 I
Recessed Light fixtures
I I I I I
1 I I I I I
I I I i I I
1 I I I I
II p I
II II I I 1 I
II II I I I - I I
II II I I I
II III I I Bookshelf Fireplace Bookshelf11 L 1
11 II I I
J -m -n - --------------------------------- J
I
II1
------------------------------------------- ----------------------------------------------------------
--------------------------
NOTE::
' The originally approved automatic fire sprinkler '
° system included fire sprinkler in the Garage area.
I 15
The heads shall be relocated thru the ceilings I A
by a licensed fire sprinkler contractor. ' A-3
L ------------------------
J
REFL CTED CEILING PLAN
0 Add: Kidde "FireX" AC Hardwired Combination Carbon Monoxide and
SD/CO Photoelectric Smoke Alarm - KN -COPE -IC or Equal
Install 12"x12" louver in Bi -Fold I Plan notes with boxes around the note indicate corrective
OLaundry Room door for make-up construction required.
I air. 1
L_ — — — _ _ — — J
2
3
4
W/H Pressure relief valve
extends thru wall and discharges
down, at floor level, +/- 18" ab.
27 29 grade 30'-5"
Single Lever0" Clear Wid h 2'-9" 4'-10" 19'-2 1/2" Clear Width
thermostatic/pressure shower Existing Existing
control valve
4'-0 1/ " 2'-3" C
Existing Flo r mounted 36 37
O Combustion Air is provided by Tub/Shove w/ Cer. Tile 1 5
6"x16" wall louvers thru the + 79" above
exterior wall at top of enclosure Wainscot A Existing HVAC P ckage Unit
and at 12" above floor of Closet p Set oii Concrete ad: Carrier
Floor at +15" about Bathroom 8 20 48GSI Gas/Elea: 1000 cfm;
_ _ 60,000 btu heatirg; 28,800 btu
Floor. O A-3 r , g
Add W.P., GFI, 20A cooli g; SEER 1b
31 Add metal strap, attached to I Outlet
6'x 4' Dbl. Glazed Sliding
I structure within bottom I
Window Sill a} +34" above floor
Loftank - - _ - - Existin Access Door
Egress Are 0.3 s.f. ;Min.
State PRV40 gallon LPG egress heig t 3'-9" ; Min. i s to Crawl Space
g width: 2'-9" 2 Q
30 Water Heater relocation -
approved Permit # 94-1833, R-3
Revision; 10.19.94 9 HVAC Disconnect HVAC Supply Main
--------------------- ------------ ------ --- --- - - ---
r— -------- —----------- =----
_7 - =. _--_ __--
71
r-
I 1
I
6
I
I
I.
I II
I Fire S rinklerVal�}e ' I 1
11 II P II LPG • ri , I f I : > jl cv
1 p ? box II 4 . Cohffrm the duplex elect ca
j
If iv II I Q W H Tub/Shower, outlet in Ba hroom is 20A and �� 1� - - - - p
W
not conn cted to loads outside y 11
of the Bath Dom. ,���' ✓�i•.� Q I
I II II I S 1� `r r
° I
34 II is { ..j1
I -
- - - r
1 -3
I r Water Heater Closet Door (1-318" I E ii 1 HVAC e> Arr ��� in `II
70
S.C.): Add listed automaticHROO -' :BEDROOM s
o I .111
j I closer, Add fisted door seals on I cit j . G r
O
w
, 1 jIr
1 I door jambs and head; Add listed I .X 11 30 x80" Do r 6' x 4' Dbl. Glazed Sliding
N
I .
I 9
W
g_
w n threshold at I . I
Doors sweep and P I
d r ttom. J Window Sill at +34" above floor -
L 20 lLo - - - -
___--_---� ��-- -- _----_----- Egress Area: 10.3 s.f. ; Min.
____-_-- 1 / m`\ �- h egress height: 3'-9" ; Min. egress
II r width: 2'-9"
I Laundry under Stair - approved 11 I GFI Q 24 I I O
Permit # 94-1833, R-3 Revision; II I o CLOS. 30" " Doo
10.19.94 11 ° DRY 1 Switched Outlet ;w;w
I O II I \� S
1 p
�7 II iii 2"x80" Do r It
11 II II J F r 11 a
4 II II °
1 p N
CARP RT
II II II L ----------I I
II II U 4----------J I 1 II
,I itj Q r II
0 1 'I
4 II j 1 I I �Conffrm that duplex electrical n U
I II I I II p
I II I I I I outlets are on circuits protected I 1 II
Existing thru-wall exh. fan 11 I fn
I 35 U I I by listed combination -type a�
interlocked with fight p 1 I I I o
I arc -fault circuit interruptor.
L _ _ _ _ _ _ _ J LIVING o II 6'x 4' Dbl. Glazed Sliding
o I1 Window Sill at +34" above floor
I II
I ---m - --� n 17 ROOM LL
11 O
- -$ ---- j j 4" onc. slab -on -grade w/ o
1 c I V por retarder - constructed
a y an approved Permlit # 94-1833
I 23 x II ---
1 O w II I
1 Existing Wall mounted LED Light ---£ -----° I Confirm that all duplex outlets
jFixture ji 'c _--- j j I are tamper resistant. Replace I II
1 I I 6 r I 47 I with tamper -proof outlets if I h
OMetal Clad I existing outlets are not compliant. I l
II Pr. 2-10 French Doorsh
I L - - - - - - - - -� II
I
1'i a ii I I
p u U I 11 �
jl II II I 11 `.-
--Et96�
Bookshelf r I e Bookshelf
iiit ui F1 ------- ------------ -------------_____________ 'I o
IILL �I wags I ------- I r
U11 i I� II II I II I 11 N
------------------------- --------fr i I ______-_-_
47 �'' }, :.` ' •~. "•; Exterior Walls: 2x6 Wood Frame
O Existing eta '\Faced i ;'...' '
36"x80" oor ��' ';' ' y' r. w/ Cement Plaster o/ plywood
.«..'.,.... .. •,;..; ...;: r Existing Gara a Door PYN
•:,•: •.:.: ; •:.•, +,. „, ;.Exisi`ui G rages Door Inoperable Original Construction under
U•' :,; r O s er le Security _ _ Permit # 94-1833
.. •.
r- - - - - - - - ---- - -- ------------------------ - 15 45
Overlay existing concrete sidewalk with I I Slope of Overlay shall not I 15
Mapei's "Quickpatch ". Follow mfgr's. exceed a"/Ft. within T-0" of the A
instructions for application. Clean existing 1 I french doors, full width of the 1
1 sidewalk prior. Feather edges at existing I 1 doors, to provide code compliant
L sidewalk to avoid tripping hazard. - J L "level landing". _ - - J /� -3
1 O 4'-0" 1'-11 1/2 1 O /`� 3'-5 1/2
Ex. Stair
12'-9 1l2 13'-2 1/2
GROUND FLOOR PLAN.
n
Existing Wood Frame Wall -Approved B.P. # 94-1833
New 2x4, Non-bearing Wood Frame Wall - Constructed after B.P. # 94-1833
Wood Framed Floor - Constructed under B.P. # 94-1833
• i Overlay of Existing Sidewalk for "Level Landing"
Install 12"x12" louver in Bi -Fold I Plan notes with boxes around the note indicate corrective
3 Laundry Room door for make-up construction required.
air. 1
L .- — — J
OCircled Number is a reference to Plan Check comments
5 6 7 9 I 10 I 11 I 12
NOTE:
The original residence construction included an
approved automatic fire sprinkler system. The
un -permitted construction under consideration for
this project did not have the sprinkler heads in
the original garage extended thru the ceilings in
response to the revised use and configuration.
This project requires that a licensed fire sprinkler
contractor modify the existing piping and head
locations as necessary to conform to code
minimums. 'This contractor shall obtain approval
from Butte County Building Department prior to
making changes.
Lar E. Coffman Architect is not responsible for
Larry p
the fire sprinkler system and it's modifications.
13 14
15
16
0
MW
� u
NorMSt expressly Nreserves Ks totm on law enand other ro hese
rights for IIideas, pr v�ans and plans represented or indicaed by
drawings. Including the principles of design. These plans are not to be
reproduced, changed, copied or loaned In any form or matter whatsoever,
—
nor are they to be assigned to any third party without the expressed
written consent of NorthStar. They are also not to be used in any manner
that may constitute a detriment directly or indirectly to NornStar.
Acceptance of these drawings Is an agreement tD these terms.
O
•r
CD
0
1-J
0
Ln
F
r
0)
O
E
U
U
C.
SIS
U
�
=
N
C5
aA
U
�
�>
i
In
p
O
N
a
u)
G
LLJ
Cd
W
CO
CN
0
O
00
0
_J
CO
r
,
rn
0
2
U
00
Z
^
H
O
IZ
co
0
Z
�•
NLU
Z
O
U)
g
CL
r
� u
J
K
L
Sheet Title:
Floor Plan
Reflected Mg.
Scale: 1/4" = l'-0"
Status:
CONSTRUCTION DOCUMENTS
Drawn :By: LEC
Checked By: LEC
Date Issued: April 2017
Project No. 17-067
Sheet No.
A-2
NorMSt expressly Nreserves Ks totm on law enand other ro hese
rights for IIideas, pr v�ans and plans represented or indicaed by
drawings. Including the principles of design. These plans are not to be
reproduced, changed, copied or loaned In any form or matter whatsoever,
—
nor are they to be assigned to any third party without the expressed
written consent of NorthStar. They are also not to be used in any manner
that may constitute a detriment directly or indirectly to NornStar.
Acceptance of these drawings Is an agreement tD these terms.
0
F
;~
O
C.
SIS
U
W
C5
�
�>
(�
!1
N
O
a
u)
G
Cd
W
CN
Cid+
00
0
H
0
0
J
K
L
Sheet Title:
Floor Plan
Reflected Mg.
Scale: 1/4" = l'-0"
Status:
CONSTRUCTION DOCUMENTS
Drawn :By: LEC
Checked By: LEC
Date Issued: April 2017
Project No. 17-067
Sheet No.
A-2
C
I
E
F
Ee
H
1
1
2
3 4 i 5 i 6 l 7
1 2 3
I.
Operable Garage
Door for Securiity
Dashed Lines indicate
construction approved
under Permit # 94-18%2
(3)
Vapor Barrier
PARTIAL GARAGE SECTION
8 9 10 11
UPPER LIVING SPACE
Original Fire Rated Fluor
12 , 13 1 14
Original Residence:
Permit # 94-1833, Exterior wall finish: 3 coat 15
Wood Frame Walls I „ Cement Plaster plywood
and Floor „ 11 o/ 2x6 studs with R-19 batt
i I
I �
ROOM
I
.0 w/ I I
I
Circled Number is a reference to Plan Check comments
insulation and 2" Gyp. Bd. -7
Existing HVAC Unit feeding
Ground Level Living Space,
ii lr%;+ nom+ ter% ('r%il r%,-%rJ
311 1 1-011
4
15
ift
16
IA
� 0
1C
O
•r O
+� CV
O
LO
r rn
)
Q
cn 0
•,. U p
U
V) m
� U �
r = i
CZ
aA U
r- C
O O
� C
'
O W
1
C)O
O
J .,, O
m l
*' _ 0)
U co
Z ^
Q O
LO
Z
OW
U) z
L O: C.2
T
T
T
J
K
L
NorthStar expressly reserves its common law copyright and other property
rights for all Ideas, provisions and plans represented or Indicated by these
drawings, including the principles of design. These plain are not to be
reproduced, changed, copied or loaned in any form or matter whatsoever,
—
nor are they to be assigned to any third party without the expressed
written consent of NorthStar. They are also not to be used in any manner
that may constitute a detriment directly or indirectly to NorthStar.
Acceptance of these drawings is an agreement to these terms.
e e
11
F
O
H
W 4!
U
/)
z
O
Lr,
W
oa
-
+ CIO
H
e e
J
K
L
Sheet Title:
Building
Section
Scale: 3/4" = F -O"
Status:
CONSTRUCTION DOCUMENTS
Drawn By: LEC
Checked By: LEC
Date Issued: April 2017
Project No.
17-067
Sheet No.
A-3
11
.M1111111111
1.
Sheet Title:
Building
Section
Scale: 3/4" = F -O"
Status:
CONSTRUCTION DOCUMENTS
Drawn By: LEC
Checked By: LEC
Date Issued: April 2017
Project No.
17-067
Sheet No.
A-3