HomeMy WebLinkAboutB17-0435 039-540-003itte Count
a
BUTTE COUNTY AREA
DEPARTMENT OF DEVELOPMENT SERVICES 5
INSPECTION CARD MUST BE ON JOB SITE {
24 Hour Inspection Line (IVR) :530.538.4365 (Cut off time for inspections is 3pm).
Development Services cannot guarantee inspections on the date requested
Office: 530.538.7601 Fax: 530
Permit No: B17-0435 Issued: 3/15%2017
APN: 039=540-003
Address: 9488 DILLON CT, DURHAM .
Owner: CARLSEN KENNETH C
Permit Type: HVAC C/O RESIDENTIAL
Description: Replace existing, split HVAC equipment
www.butteuounty.nevatls
Flood Zone: None SRA Area: No
SETBACKS for Zoning, AG_ SRA_ PW
Front: Centerline of Road:.
Rear: SRA:
Street: AG:
Interior
Total Setback from Centerline of Road:
ALL PLAN•REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING
Inspection e
IVR INSP DATE
Setbacks
131
Foundations / Footings
111
Pier/Column Footings
122
Eufer Ground
216
Masonry Grout
120
Setbacks
131
Do Not Pour Concrete Until Above are Sign d
Pre -Slab
124
Gas Test Underground/floor
404
Gas Piping Underground/floor
403
Underfloor Framing
149
Underfloor Ducts
319
Shear Transfer
136
Under Floor Plumbing
412
Under Slab Plumbing
411
Blockin nder inin
.612
Tiedown/Soft Set System
611
Do Not Install Floor Sheathing
or Slab Until Above Signed
ShearwallB.W.P.-Interior
134
ShearwallB.W.P.-Exterior
135
Roof Nail/Drag Trusses
129
Manometer Test
605
Do Not Install Sidin Stucco or Roofing Until Above Signed
Rough Framing
153
Rough Plumbing
406
Rough Mechanical
316
Rough Electrical
208
4 -Way Rough Framing
128
Gas Piping House
403
Gas Test House
404
Shower Pan/Tub Test
408
Do Not Insulate Until Above Si ned
Permit Final -
802
Electrical Final
803
Mechanical Final
809
Plumbing Final
813
Fire Sprinkler Test or Final
702
1-17
1
r
Inspection T e
IVR INSP DATE
T -Bar Ceiling
145
Stucco Lath
142
Swimming
Pools
Setbacks
131
Pool Plumbing Test
504
Gas Test
404
Pre-Gunite
506
Pre -Deck
505
Pool Fencing/Alarms/Barriers
503
Pre -Plaster
507
Manufactured Homes
Setbacks
131
Blockin nder inin
.612
Tiedown/Soft Set System
611
Permanent Foundation System
613
Underground Electric
218
Sewer
407
Underground Water
417
Manometer Test
605
Continuitv Test
602
Skirtin Ste s/Landin s
610
Coach Info
Manufactures Name:
Date of Manufacture:
Model Name/Number:
Serial Numbers:
Length x Width:
Insignia:
Finals.
Public Works Final 538.7681
Fire De artment/CDF 538.6226
Env. Health Final 538.7281
Sewer'District Final
"PROJECT FINAL �<
-rrolecr anal is a lRrnECa[e of uccupancy Ior (mesfaenthal Unly)
PERMITS BECOME NULL AND VOID 1 YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A 1 YEAR
RENEWAL 30 DAYS PRIOR TO EXPIRATION
` y. �..:'
,Carbontmonoxide-ala'Ni required by:Sections R31.5' and 'R315.2 shall be'installed in the'-.
ifollowing locabonss
`1 ;Outside of each separate dwelling unit sleeping area in the iinm@diate vidinh,ofthe .
bedrooms
2 On everylevel of a°dwelling;unit including basements
R315'1:5yMultipte-purpose;;alarms:.,Carbon monoxide-alarms combined with smoke alarms
s .,+
shall'coinpty; "`with Section R315, all applicable standards;, and requirements four listing and, -
;approval bythe,,Office of tt e:State;F.ire Marshal;•for smoke�alarm s.� �� �t „�
�M1 r- f, e - ••'yt.i }• i -
'� :Butte Count-A iy's Interpretation,,of 2013 CRC., Sections` 3' 4�8i`'315 for °
Smoke�Alarms,&,Carbon Monoxide-Alarms: a� � a� ;'
ae_ s `�`� � lei '� y' r i ,� �^, .
Where alterations, repairs or additions exceeding $1,000 in valuation, existing dwellings:§hall be, ,
• . s retrofitted witl'Smoke alarms and those that have attached aaraaes or fuel burning avuliances shall have a"
.. :-
carbon monoxide alarms'` installed Existing smoke alarms can be replaced with dual function alarms for
3 �' G6. -
Smoke and Cabori Monoxide:and in most. cases will :comply with the;aforementioned code requirements^;
L
-
for Carbon 1Vlonoxide 7"Alarms. t �+ '•
c i
• - _ � �'. i-tib. ..
DECLARATION OFINSTALILATION. UNDER,THE PENALTY OF.PERJURY;' , '#
o
under the laws ,
As Owner/Contractor, %ye affirm and declare under the penalty of perjury
y ,
a.
of the State of California, by our signatures below as OwnerlContractor, that Ilwe will
t` comply prior to final inspection with Items A & B as specified herein:
A Both OvvnerZContractor have read and clearly understand the aforement oned'2010 Y t
4 . California Residential:Code (CRC) Carbon Monoxide Alarm.requirements..
B. Boni Owner/Contractor are responsible for installing. Carbon Monoxide Alarrns.pnor to tse Y
final inspection as per the aforementioned building code'and maintaining such
nstallation. Smoke Alarms will also be installed prior to final inspection as per.ttie 201U
CRC: g
Smokex rid Carbon Monoxide ala s are now installed in the following locations i y
o r 3 s
Ken Carlson _
Owner's name (print): _
��,11 VV �Date:
Ownees. signature: _
William Story CSLB License: 842922:
Contractor's: name (print):
Date:
Contractor's signature: x
9488 Dillion Ct. Durham CA 95938 Permit #: 1317-0435
Project Address: 3
Page 2 of 2
Revised 7.20.2015
N