Loading...
HomeMy WebLinkAboutB17-0528 000-000-000 (4)2 RECEIVED - ENGINEERING 1574 Lilac Way, Paradise CA 95969 JUN 2 0 2017 Cell (530) 966-6849 TRB AND ASSOCIATES June 14, 2017 TRB+Associates RE: Plan Review for: Salas Residence—New SFD Project Address: 0 Hogan Rd, Cohasset Agency App. No: B17-0528 - TRB+ Project No: PC17.054.107.2 I have numbered the following responses to coincide with your review of the Salas plans. ARCHITECTURAL COMMENTS No response required GREEN BUILDING COMMENTS No response required ENERGY COMMENTS No response required MECHANICAL COMMENTS No response required PLUMBING COMMENTS , BUTTE No response required COUNW WILDFIRE EXPOSURE CONSTRUCTION REQ JUN 1 DEVELOPMENT No response required SERVICES STRUCTURAL COMMENTS 7 "0Sa59 S1. The SSTB16 has been changed to a SSTB20: S6. All truss loads now accounted for. : . a. Placed a new note on sheet S3 calling out direct bearing to be placed below trusses C10 through C12 and showed which trusses they are. All areas checked and are not over loaded. b. Nothing c. Crushing capacity of 2x6 perpendicular to grain is 5,156 lb. Alterations have been made at locations that need addressing, see "new comment" below. NEW COMMENT Was considering that header to be an exterior wall and land under the 6x12 note but have now written it on the plans and showed it there. Double studs or blocking now called out to deal with perpendicular to grain issues along with TBE6's that were added to enhance the bearing capacity of the trusses over that wall. If you have any questions regarding the plans or calculations please email or call my cell at (530) 966-6849. Thanks, Luke A. Wentland, PE