Loading...
HomeMy WebLinkAboutB17-0634 055-480-005BUTTE COUNTY AREA DEPARTMENT OF DEVELOPMENT SERVICES 3 INSPECTION CARD MUST BE ON JOB SITE 24 Hour Inspection Line (IVR) : 530.538.4365 (Cut off time for inspections is Spm) Development Services cannot guarantee inspections on the date requested Office: 530.538.7601 Fax:530.538.7785 www.ButteCountv.net/dds Permit No: B17-0634 Issued: 4/10/2017 APN: 055-480-005 Address: 4965 LAGO VISTA WAY, PARADISE Owner: HORNER CRAIG & SHIRLEY FAMILY Permit Type: ELECTRIC PANEL RES Description: TESLA BATTERY FOR SOLAR. Flood Zone: None SRA Area: Yes Front: Centerline of Road: Rear: SRA: Street: AG: Interior Total Setback from Centerline of Road: ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING Inspection Type IVR INSP DATE Setbacks 131 Foundations / Footings 111 Pier/Column Footings 122 Eufer Ground 216 Masonry Grout 120 Setbacks 131 Do Not Pour Concrete Until Above are Signed Pre -Slab 124 Gas Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing 149 Underfloor Ducts 319 Shear Transfer 136 Under Floor Plumbing 412 Under -Slab Plumbing 411 Blocking/Underpining 612 Tiedown/Soft Set System 611 Do Not Install Floor Sheathing or Slab Until Above Signed Shearwall/B.W.P.-Interior 134 ShearwalUB.W.P.-Exterior 135 Roof Nail/Drag Trusses 129 417 Manometer Test Do Not Install Siding/Stucco or Roofing Until Above Signed Rough Framing 153 Rough Plumbing 406 Rough Mechanical 316 Rough Electrical 208 4 -Way Rough Framing 128 Gas Piping House 403 Gas Test House 404 Shower Pan/Tub Test 408 Do Not Insulate Until Above Signed Permit Final 802 Electrical Final 803 Mechanical Final 809 Plumbing Final 813 Fire Sprinkler Test or Final 702 Swimming Pools Inspection Type IVR INSP DATE T -Bar Ceiling 145 Stucco Lath 142 Swimming Pools Setbacks 131 Pool Plumbing Test 504 Gas Test 404 Pre-Gunite 506 Pre -Deck 505 Pool Fencing/Alarms/Barriers 503 Pre -Plaster 507 Manufactured Homes Setbacks 131 Blocking/Underpining 612 Tiedown/Soft Set System 611 Permanent Foundation System 613 Underground Electric 218 Sewer 407 Underground Water 417 Manometer Test 605 Continuity Test 602 Skirting/Steps/Landings 610 Coach Info Manufactures Name: Date of Manufacture: Model Name/Number: Serial Numbers: Length x Width: Insignia: Finals Public Works Final 538.7681 Fire De artment/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final **PROJECT FINALLLJ -rrujeci rmai is a %-erancare of occupancy for tnesiaennai vniy) PERMITS BECOME NULL AND VOID 1 YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A 1 YEAR RENEWAL 30 DAYS PRIOR TO EXPIRATION ' Y• BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT 24 HOUR INSPECTION (IVR)#:530.538:4365 OFFICE #: 530.538.7601 FAX#:530.538.7785 www.ButteCounty.net/dds Square Footage: H1 00 SOLARCITY CORPORATION DBA TESLA I . SOLARCITY - PROJECT INFORMATION SAN MATEO, CA 94402_ Site Address: 4965 LAGO VISTA WAY. 6509635100 0 0 0 Owner: Permit NO: B 17-0634 APN: 055-480-005 - I SOLARCITY 888104 / C46 / 12/31/2018 . HORNER CRAIG & SHIRLEY F CONSTRUCTION LENDING AGENCY DECLARATION Permit type: MECH ELECTRIC PLUMB (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license i 4965 LAGO VISTA WAY Issued Date: 4/10/2017 By JMD Subtype: ELECTRIC PANEL RES Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of PARADISE, CA 95969 Expiration Date: 4/10/2018 necrrintinn• TRCi.A RATTPRV PnR 4ZC11.AR do U all of or U portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the ' building or improvement is sold within one year of completion, the Owner -Builder will have the - Occunancv: Zoning: none Square Footage: H1 00 SOLARCITY CORPORATION DBA TESLA I . SOLARCITY Carrier. ZURICH AMERICANPolicy NumbErINSMR9MR Exp. t$f1fJ2017 ElI certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if 1 should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. X I am exempt from licensure under the Contractors' State License Law for the following 13 reason: X Owner's Siqnature Date Signature Date BuilOing Gaflige RemdlYAddn 3055 CLEARVIEW 3055 CLEARVIEW SAN MATEO, CA 94402_ SAN MATEO, CA 94402 Other Porch/Patio Total 6509635100 6509635100 0 0 0 .'LICENSED CONTRACTOR'S DECLARATION OWNER / BUILDER DECLARATION Contractor (Name) State Contractors License No. / Class / Expires I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for SOLARCITY 888104 / C46 / 12/31/2018 the reason(s) indicated below by the checkmark(s) I have placed next to the applicable item(s) (Section CONSTRUCTION LENDING AGENCY DECLARATION 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she licensed pursuant to the provisions of the Contractors' I HEREBY AFFIRM UNDER PENALTY OF PERJURY that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license i State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Businesss and in full force and effect. Professions Code) or that he or she is exempt from licensure and the basis for the alleged exemption. X Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of of Permittee [SIGN] Print Date not more than five hundred dollars ($500).): I, as owner of the property, or my employees with wages as their sole compensation, will ❑ Contractor's Signature Date do U all of or U portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the ' building or improvement is sold within one year of completion, the Owner -Builder will have the WORKERS' COMPENSATION DECLARATION - I HEREBY AFFIRM UNDER PENALTY OF PERJURY one of the following declarations: have and will maintain a certificate of consent to self -insure for workers' burden of proving that it was not built or - ❑I compensation, issued by the Director of Industrial Relations as provided for by Section improved for the purpose of sale.). 3700 of the Labor Code, for the performance of the work for which this permit is issued. Policy No. - 1, as owner of the property, am exclusively contracting with licensed Contractors to construct the project (Section 7044, Business and Professions Code: The Contractors' State ❑El I have and will maintain workers' compensation insurance, as required by Section 3700 of - License Law does not apply to an owner of property who builds or improves thereon, and who the Labor Code, for the performance of the work for which this permit is issued. My workers contracts for the projects with a licensed Contractor pursuant to the Contractors' State License compensation insurance carrier and policy number are: - Law.), - Carrier. ZURICH AMERICANPolicy NumbErINSMR9MR Exp. t$f1fJ2017 ElI certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if 1 should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. X I am exempt from licensure under the Contractors' State License Law for the following 13 reason: X Owner's Siqnature Date Signature Date By my signature below, I certify to each of the following: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS I am L) a California licensed contractor or L) the property owner' or U authorized to UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES act.on the property owner's behalf**. I have read this construction permit application and the information I have provided is AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN correct. ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN t agree to comply with all applicable city and county ordinances and state laws relating SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. • to building construction. authorize representatives of this city or county to enter the above -identified property for inspection purposes. California Licensed Contractor, Property Owner' or Authorized Agent": 'requires separate verification form "requires separate CONSTRUCTION LENDING AGENCY DECLARATION - I hereby affirm under penalty of perjury that there is a construction lending agency for the authorization form performance of the work for which this permit is issued (Section 3097, Civil Code). Lender's Name and Address - - X of Permittee [SIGN] Print Date -.Name Lender's Name & Address City State Zip FEE INFORMATION Total Fees:. $156.00 Fees Paid: $156.00 Balance Due: (None) Job Value: $7,099.50 r.GROUND SPECS "--- MAIN PANEL SPECS _:_ GENERAL NOTES ,... = _ , _ _ _ _ _ :. —LICENSE (E) GROUND ROD AT PANEL Panel Number: M400—UG—APS-LC CA # 888104 �,- Meter Number: 1009864388 C-10 �E 200A MAIN SERVICE PANEL - N) 125A/2P MAIN CIRCUIT- BREAKER AUTOMATIC RELAY no (N) Bryant . (N)125A/2P 125A Load Center UNINTERRUPTIBLE (E) LOADS Z POWER SUPPLY Y 30A/2P Ll 6OA/2P — — — G — — — — _13) EGC/GEC — _ --- GEC---� - � J O 120/240V I' SINGLE PHASE 1 UTILITY SERVICE r a TO (E) LOADS v V60 = MAX VOC AT MIN TEMP POI . (1)CUTLER-HAMMER A BR260 . -, Breaker, 60A 2P, 2 Spaces AC WERWALL 5.BkVA; Home Energy Storoge,13.OKWH - Rev C . X (1) Tesla ! 1108567-00-G ' �� y i Z (1)Teslo p 1118431-00-6 BACK UP GATEWAY; for ACPW2.0, ASY, NA with 3G, Rev B (1)BRYANT g BR1224L125G Y Load Center, 125A, 120/24OV, NEMA 1 -(11 )Teslo 0 1112484-06-4 Meter Kit; Asy,W CURRENT; XFMR. ENERGY GATEWAY for ACPW2.0,. with 2 CT's - (1)CUTLER=HAMM8 'R230 Battery Breaks'' Breaker, 3OA72P, 2 Spaces ,- -(2)CUTLER-HAMM # BD1 15 Relocated Loads Breakers Breaker, 15A 1P-15A/lP, 1 Space, Duplex -(2 )CUTLER-HAMM ®BD2 20 Relocated Loads Breakers Breaker, 20A 1P -20A IP, 1 Space, Duplex ti 1 AWG 82, THWN-2, Block O (1) AWG #2, THWN-2. Red (I )AWG (1)AWG #10, THWN-2, Black ®� (1) AWG #10, THWN-2, Red (1)AWG THWN-2, White #2,.'THWN-2, White NEUTRAL #10, , NEUTRAL . (11 )AWG #8, THWN-2, Green EGC - (1) Conduit Kit; 1-1/4'• EMT - (1)AWG 0, THWN-2 Green EGC ..: -.(1 Conduit Klt. 3/4' EMT • ; • , CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NUYBEk JB -9597222 0 0 PREMISE OWNER: HORNER; r CRAIG DESCRIPTION: HORNER RESIDENCE DESIGN: Chris VargasSolarCity �\`w TING SYSTEM: ! • NOR'SHALL IT BE DlsaosEo 1N MOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS able To Calculate Mounting Hardware' [INVERTER.- 4965 LAGO VISTA: WAY 0 KW PV ARRAY • PARADISE; CA 95969 - LES: ORGANIZATION. EXCEPT IN CONNECTION WITH. 3055 Clearvlew Way - CA 94402 T:(650) 638-102Son 8 F:(650) 638-1029 THE SALE AND USE OF 1HE;RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN ) ' PAGE NAME' UAIE PERMISSION of soLARaTY INc.THREE LINE DIAGRAM SC TAB 4/4/2017 (888) -SOL -CITY (765-2489) www.solareitycom T PO`WERWALL • �.% Tesla Powerwall 2 is a fully -integrated AC battery system for s residential or light commercial use. Its rechargeable lithium -ion battery pack provides energy storage for solar self -consumption, •load shifting, backup power, and off -grid use. ' •' ' � - is Powerwall's electrical interface provides a simple connection to "; a any home or building. Its revolutionary compact design achieves market -leading energy density and is easy to install, enabling owners to quickly realize the benefits of, reliable, clean power. PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS ................ -------.......... _------- --- ----------------_.__.--------------------- -------------- ------------ - AC Voltage (Nominal) 208 V, 220 V, 230 V, --------------------------------------------- Dimensions - - - --------- --- .-..... ------ --- ------- 1150 mm x 755 mm x 155 mm 100/200 V 120/240 V ------- --........... ........................... ----------------------------------------------------------- ---------------------------------------------------------------------I-------------------- (45.3 in x 29.7 in x 6.1 in) ------- --------- --------- - --- -....... Feed-In Type Single & Split Phase Weight --------------.................. -..... 125 kg (276 lbs) ........ - ............................................. --------------------------------------- - ----------------------------....._......-----......-----------------........................ -- - ------------. Grid Frequency 50 and 60 Hz Mounting options Floor or wall mount ............................................................................................................................................ AC Energy' 13.2 kWh ... ---------------------------------------- ------------------ = - ------------------ENVIRONMENTAL Real Power, max continuous .5 kW (charge and discharge) ...........................................-------............................__.....---..............._................... ' SPECIFICATION S . _......... Real Power, peak (10s)2 7 kW (discharge only) t ...........-...................... ................................................................--........................---.. Operating Temperature -20°C to 50°C (-4°F to 122°F) Apparent Power, max continuous5.8 kVA (charge and discharge) ................................................._..-----.................. -- - ... -........................................... -...............................- --------------------------------------._.............----------------...I..-----.............. Operating Humidity (RH) -- --- Up to 100%, condensing Apparent Power, peak (10S)2 7.2 kVA (discharge only) --._... - - - - - ....:a._......... -------------------- .-------•-------- Maximum Altitude _ --------- ---- ------•-------------------------------------•-- 3000 m (9843 ft) ------------- Imbalance for Single -Phase Loads 100% ..... ...... ........................... ... -....... - -------------- .----- .....-------...................................._........................... Environment ---- ------------......---..............--- Indoor and outdoor rated ------- --------- ---------------•--------___.__-_-.-....... Power Factor Output Range +/-1.0 adjustable ........ ........................... ............._............. -------•----•------------------------------------ ..- ----- ----... Enclosure Type NEMA 3R Power Factor (full -rated power) +/-0.85 ............ ............ ............... Ingress Rating -------------- - - - ... --- - IP67 (Battery & Power Electronics) ------------------- ................ .......................... -...... ------ ---- - -•----------------------- IP56 (Wiring Compartment) Depth of Discharge . 100% ........................... ...................... ----------­-­------- ------...._.....................-............................ Noise Level @ 1 m ' <40 dBA at 30°C (86°F) Internal Battery DC Voltage 50V ......--- .....................-----------------.................................... -----------------------.......----------........._._.....----.._..-----......--------------- --- -- - -- -- ---------- Round Trip Efficiency' .3 89.0% ........:................................................................................---.------------------. BACKUP ENERGY GATEWAY SPECIFICATIONS Warranty 10 years - ---- -- - ....._.__._._ - ---- - - - - - -- - -- - - - ---------------------_.._...----- .-•-----•----------------------------.....................--------....................................... 'Values provided for 25°C (770F), 3.3 kW charge/discharge power. Dimensions 691 mm x 378 mm x 129 mm 2Values region -dependent. (27.2 in x 14.9 in x 5.1 in) 3AC to battery to AC, at beginning of life. ............................`----------------..-................ ......._. - -- .,.................................-............. ' * Wei We ght .......... -............ ...................-----_......--------..............--------- 16.44kg( 36 lbs) ------------------------ ------- ....... Disconnect Current 200 A COMPLIANCE INFORMATION r Enclosure Type NEMA 3R J - - -- ------------------------------------------------------------------------------------------------------------ Ingress Rating IP24 SafetyUL 1642, UL 1741, UL 1973, .......... ...... ..... ........... ....... ......................... ................... --------------...............=-----......-- UL 9540, UN 38.3, IEC 62109-1, Overcurrent Protection Breaker' 100-200 A C22.2.107.1 IEC 62619, CSA _- -----------..............:....... .................. -.......................................................--- - ---- ........ -- ................................ ..................................................................................... User Interface ..................... Tesla App Grid Standards . Worldwide Compatibility -------- ------ -- - -- — --' -- - -- ---- - - -- ....------------------------------------------------------------------------- Connectivity ..................................................... Wi-Fi, Ethernet, 3G° Emissions'.. ---------------------'------'-----.-------------------- AC Meter - ------------------------------- ------ -- Revenue grade EN 61000 Class B Environmental RoHS Directive 2011/65/EU, Operating Modes Support for solar self -consumption, WEEE Directive 2012/19/EU, backup, load shifting, off -grid, export limits 2006/66/EC Backup Operation Automatic disconnect for seamless ...................................................... --------- ----•--- .................... ----------------................................. Seismic AC156, IEEE 693-2005 (high)backup - - -............ - ..... ------- ---------------------•--------------------------------------------------------------------------- transition - ..-----._...-------- •-----------................-............--------....-.......--------...........................--- - Modularity Supports up to 10 AC -coupled Powerwalls -----------•_-------_-------- ------ 'Optional --------------............-- ---------------- T = 5 L n TESLA.COM/ENERGY