HomeMy WebLinkAboutB17-0634 055-480-005BUTTE COUNTY AREA
DEPARTMENT OF DEVELOPMENT SERVICES 3
INSPECTION CARD MUST BE ON JOB SITE
24 Hour Inspection Line (IVR) : 530.538.4365 (Cut off time for inspections is Spm)
Development Services cannot guarantee inspections on the date requested
Office: 530.538.7601 Fax:530.538.7785 www.ButteCountv.net/dds
Permit No: B17-0634 Issued: 4/10/2017
APN: 055-480-005
Address: 4965 LAGO VISTA WAY, PARADISE
Owner: HORNER CRAIG & SHIRLEY FAMILY
Permit Type: ELECTRIC PANEL RES
Description: TESLA BATTERY FOR SOLAR.
Flood Zone: None SRA Area: Yes
Front: Centerline of Road:
Rear: SRA:
Street: AG:
Interior
Total Setback from Centerline of Road:
ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING
Inspection Type
IVR INSP DATE
Setbacks
131
Foundations / Footings
111
Pier/Column Footings
122
Eufer Ground
216
Masonry Grout
120
Setbacks
131
Do Not Pour Concrete Until Above are Signed
Pre -Slab
124
Gas Test Underground/floor
404
Gas Piping Underground/floor
403
Underfloor Framing
149
Underfloor Ducts
319
Shear Transfer
136
Under Floor Plumbing
412
Under -Slab Plumbing
411
Blocking/Underpining
612
Tiedown/Soft Set System
611
Do Not Install Floor Sheathing or Slab Until Above Signed
Shearwall/B.W.P.-Interior
134
ShearwalUB.W.P.-Exterior
135
Roof Nail/Drag Trusses
129
417
Manometer Test
Do Not Install Siding/Stucco or Roofing Until Above Signed
Rough Framing
153
Rough Plumbing
406
Rough Mechanical
316
Rough Electrical
208
4 -Way Rough Framing
128
Gas Piping House
403
Gas Test House
404
Shower Pan/Tub Test
408
Do Not Insulate Until Above Signed
Permit Final
802
Electrical Final
803
Mechanical Final
809
Plumbing Final
813
Fire Sprinkler Test or Final
702
Swimming
Pools
Inspection Type
IVR INSP DATE
T -Bar Ceiling
145
Stucco Lath
142
Swimming
Pools
Setbacks
131
Pool Plumbing Test
504
Gas Test
404
Pre-Gunite
506
Pre -Deck
505
Pool Fencing/Alarms/Barriers
503
Pre -Plaster
507
Manufactured Homes
Setbacks
131
Blocking/Underpining
612
Tiedown/Soft Set System
611
Permanent Foundation System
613
Underground Electric
218
Sewer
407
Underground Water
417
Manometer Test
605
Continuity Test
602
Skirting/Steps/Landings
610
Coach Info
Manufactures Name:
Date of Manufacture:
Model Name/Number:
Serial Numbers:
Length x Width:
Insignia:
Finals
Public Works Final 538.7681
Fire De artment/CDF 538.6226
Env. Health Final 538.7281
Sewer District Final
**PROJECT FINALLLJ
-rrujeci rmai is a %-erancare of occupancy for tnesiaennai vniy)
PERMITS BECOME NULL AND VOID 1 YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A 1 YEAR
RENEWAL 30 DAYS PRIOR TO EXPIRATION
' Y•
BUTTE COUNTY
DEPARTMENT OF DEVELOPMENT SERVICES
BUILDING PERMIT
24 HOUR INSPECTION (IVR)#:530.538:4365
OFFICE #: 530.538.7601 FAX#:530.538.7785
www.ButteCounty.net/dds
Square Footage: H1 00
SOLARCITY CORPORATION DBA TESLA I . SOLARCITY
-
PROJECT
INFORMATION
SAN MATEO, CA 94402_
Site Address:
4965 LAGO VISTA WAY.
6509635100 0 0 0
Owner:
Permit NO: B 17-0634
APN:
055-480-005 - I
SOLARCITY 888104 / C46 / 12/31/2018
. HORNER CRAIG & SHIRLEY F
CONSTRUCTION LENDING AGENCY DECLARATION
Permit type:
MECH ELECTRIC PLUMB
(commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license i
4965 LAGO VISTA WAY
Issued Date: 4/10/2017 By JMD
Subtype:
ELECTRIC PANEL RES
Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of
PARADISE, CA 95969
Expiration Date: 4/10/2018
necrrintinn•
TRCi.A RATTPRV PnR 4ZC11.AR
do U all of or U portions of the work, and the structure is not intended or offered for sale
(Section 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who, through employees' or personal effort, builds or improves the
property, provided that the improvements are not intended or offered for sale. If, however, the
' building or improvement is sold within one year of completion, the Owner -Builder will have the
-
Occunancv: Zoning: none
Square Footage: H1 00
SOLARCITY CORPORATION DBA TESLA I . SOLARCITY
Carrier. ZURICH AMERICANPolicy NumbErINSMR9MR Exp. t$f1fJ2017
ElI certify that, in the performance of the work for which this permit is issued, I shall not
employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if 1 should become subject to the workers'
compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those
provisions.
X
I am exempt from licensure under the Contractors' State License Law for the following
13 reason:
X
Owner's Siqnature Date
Signature Date
BuilOing Gaflige RemdlYAddn
3055 CLEARVIEW
3055 CLEARVIEW
SAN MATEO, CA 94402_
SAN MATEO, CA 94402 Other Porch/Patio Total
6509635100
6509635100 0 0 0
.'LICENSED CONTRACTOR'S DECLARATION
OWNER / BUILDER DECLARATION
Contractor (Name) State Contractors License No. / Class / Expires
I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for
SOLARCITY 888104 / C46 / 12/31/2018
the reason(s) indicated below by the checkmark(s) I have placed next to the applicable item(s) (Section
CONSTRUCTION LENDING AGENCY DECLARATION
7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter,
improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she licensed pursuant to the provisions of the Contractors'
I HEREBY AFFIRM UNDER PENALTY OF PERJURY that I am licensed under provisions of Chapter 9
(commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license i
State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Businesss and
in full force and effect.
Professions Code) or that he or she is exempt from licensure and the basis for the alleged exemption.
X
Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of
of Permittee [SIGN] Print Date
not more than five hundred dollars ($500).):
I, as owner of the property, or my employees with wages as their sole compensation, will
❑
Contractor's Signature Date
do U all of or U portions of the work, and the structure is not intended or offered for sale
(Section 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who, through employees' or personal effort, builds or improves the
property, provided that the improvements are not intended or offered for sale. If, however, the
' building or improvement is sold within one year of completion, the Owner -Builder will have the
WORKERS' COMPENSATION DECLARATION
-
I HEREBY AFFIRM UNDER PENALTY OF PERJURY one of the following declarations:
have and will maintain a certificate of consent to self -insure for workers'
burden of proving that it was not built or -
❑I
compensation, issued by the Director of Industrial Relations as provided for by Section
improved for the purpose of sale.).
3700 of the Labor Code, for the performance of the work for which this permit is issued. Policy
No. -
1, as owner of the property, am exclusively contracting with licensed Contractors to
construct the project (Section 7044, Business and Professions Code: The Contractors' State
❑El
I have and will maintain workers' compensation insurance, as required by Section 3700 of
- License Law does not apply to an owner of property who builds or improves thereon, and who
the Labor Code, for the performance of the work for which this permit is issued. My workers
contracts for the projects with a licensed Contractor pursuant to the Contractors' State License
compensation insurance carrier and policy number are: -
Law.), -
Carrier. ZURICH AMERICANPolicy NumbErINSMR9MR Exp. t$f1fJ2017
ElI certify that, in the performance of the work for which this permit is issued, I shall not
employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if 1 should become subject to the workers'
compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those
provisions.
X
I am exempt from licensure under the Contractors' State License Law for the following
13 reason:
X
Owner's Siqnature Date
Signature Date
By my signature below, I certify to each of the following:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS
I am L) a California licensed contractor or L) the property owner' or U authorized to
UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES
act.on the property owner's behalf**.
I have read this construction permit application and the information I have provided is
AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN
correct.
ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
t agree to comply with all applicable city and county ordinances and state laws relating
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
•
to building construction.
authorize representatives of this city or county to enter the above -identified property
for inspection purposes. California Licensed Contractor, Property Owner' or
Authorized Agent": 'requires separate verification form "requires separate
CONSTRUCTION LENDING AGENCY DECLARATION
-
I hereby affirm under penalty of perjury that there is a construction lending agency for the
authorization form
performance of the work for which this permit is issued (Section 3097, Civil Code).
Lender's Name and Address - -
X
of Permittee [SIGN] Print Date
-.Name
Lender's Name & Address City State Zip
FEE INFORMATION
Total Fees:. $156.00 Fees Paid: $156.00
Balance Due: (None) Job Value: $7,099.50
r.GROUND SPECS
"--- MAIN PANEL SPECS _:_
GENERAL NOTES ,...
= _ , _
_
_
_ _
:.
—LICENSE
(E) GROUND ROD AT PANEL
Panel Number: M400—UG—APS-LC
CA # 888104
�,-
Meter Number: 1009864388
C-10
�E 200A MAIN SERVICE PANEL
-
N) 125A/2P MAIN CIRCUIT- BREAKER AUTOMATIC
RELAY
no (N) Bryant .
(N)125A/2P
125A Load Center UNINTERRUPTIBLE
(E) LOADS Z
POWER SUPPLY
Y 30A/2P
Ll
6OA/2P — — — G — — —
— _13)
EGC/GEC —
_
--- GEC---�
- �
J
O 120/240V I'
SINGLE PHASE 1
UTILITY SERVICE
r a
TO (E) LOADS
v
V60 = MAX VOC AT MIN TEMP
POI . (1)CUTLER-HAMMER A BR260 . -,
Breaker, 60A 2P, 2 Spaces
AC WERWALL 5.BkVA; Home Energy Storoge,13.OKWH - Rev C .
X (1) Tesla ! 1108567-00-G ' ��
y
i
Z (1)Teslo p 1118431-00-6
BACK UP GATEWAY; for ACPW2.0, ASY, NA with 3G, Rev B
(1)BRYANT g BR1224L125G
Y Load Center, 125A, 120/24OV, NEMA 1
-(11 )Teslo 0 1112484-06-4
Meter Kit; Asy,W CURRENT; XFMR. ENERGY GATEWAY for ACPW2.0,. with 2 CT's
- (1)CUTLER=HAMM8 'R230 Battery Breaks''
Breaker, 3OA72P, 2 Spaces ,-
-(2)CUTLER-HAMM # BD1 15 Relocated Loads Breakers
Breaker, 15A 1P-15A/lP, 1 Space, Duplex
-(2 )CUTLER-HAMM ®BD2 20 Relocated Loads Breakers
Breaker, 20A 1P -20A IP, 1 Space, Duplex ti
1 AWG 82, THWN-2, Block
O (1) AWG #2, THWN-2. Red
(I )AWG
(1)AWG #10, THWN-2, Black
®� (1) AWG #10, THWN-2, Red
(1)AWG THWN-2, White
#2,.'THWN-2, White NEUTRAL
#10, , NEUTRAL .
(11 )AWG #8, THWN-2, Green EGC - (1) Conduit Kit; 1-1/4'• EMT
- (1)AWG 0, THWN-2 Green EGC ..: -.(1 Conduit Klt. 3/4' EMT • ; • ,
CONFIDENTIAL - THE INFORMATION HEREIN
CONTAINED SHALL NOT BE USED FOR THE
BENEFIT OF ANYONE EXCEPT SOLARCITY INC.,
NUYBEk JB -9597222 0 0
PREMISE OWNER:
HORNER; r CRAIG
DESCRIPTION:
HORNER RESIDENCE
DESIGN:
Chris VargasSolarCity
�\`w
TING SYSTEM: !
•
NOR'SHALL IT BE DlsaosEo 1N MOLE OR IN
PART TO OTHERS OUTSIDE THE RECIPIENTS
able To Calculate Mounting Hardware'
[INVERTER.-
4965 LAGO VISTA: WAY 0 KW PV ARRAY
•
PARADISE; CA 95969
-
LES:
ORGANIZATION. EXCEPT IN CONNECTION WITH.
3055 Clearvlew Way -
CA 94402
T:(650) 638-102Son 8 F:(650) 638-1029
THE SALE AND USE OF 1HE;RESPECTIVE
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN
) '
PAGE NAME'
UAIE
PERMISSION of soLARaTY INc.THREE
LINE DIAGRAM
SC TAB 4/4/2017
(888) -SOL -CITY (765-2489) www.solareitycom
T
PO`WERWALL
• �.%
Tesla Powerwall 2 is a fully -integrated AC battery system for
s
residential or light commercial use. Its rechargeable lithium -ion
battery pack provides energy storage for solar self -consumption,
•load shifting, backup power, and off -grid use.
' •' ' �
- is
Powerwall's electrical interface provides a simple connection to
"; a
any home or building. Its revolutionary compact design achieves
market -leading energy density and is easy to install, enabling
owners to quickly realize the benefits of, reliable, clean power.
PERFORMANCE SPECIFICATIONS
MECHANICAL
SPECIFICATIONS
................ -------.......... _------- --- ----------------_.__.--------------------- -------------- ------------ -
AC Voltage (Nominal) 208 V, 220 V, 230 V,
---------------------------------------------
Dimensions
- - - --------- --- .-..... ------ --- -------
1150 mm x 755 mm x 155 mm
100/200 V 120/240 V
------- --........... ........................... -----------------------------------------------------------
---------------------------------------------------------------------I--------------------
(45.3 in x 29.7 in x 6.1 in)
------- --------- ---------
- --- -.......
Feed-In Type Single & Split Phase
Weight
--------------.................. -.....
125 kg (276 lbs)
........ - ............................................. ---------------------------------------
- ----------------------------....._......-----......-----------------........................ -- - ------------.
Grid Frequency 50 and 60 Hz
Mounting options
Floor or wall mount
............................................................................................................................................
AC Energy' 13.2 kWh
... ---------------------------------------- ------------------ = - ------------------ENVIRONMENTAL
Real Power, max continuous .5 kW (charge and discharge)
...........................................-------............................__.....---..............._...................
' SPECIFICATION S
. _.........
Real Power, peak (10s)2 7 kW (discharge only) t
...........-...................... ................................................................--........................---..
Operating Temperature
-20°C to 50°C (-4°F to 122°F)
Apparent Power, max continuous5.8 kVA (charge and discharge)
................................................._..-----.................. -- - ... -...........................................
-...............................-
--------------------------------------._.............----------------...I..-----..............
Operating Humidity (RH)
-- ---
Up to 100%, condensing
Apparent Power, peak (10S)2 7.2 kVA (discharge only)
--._... - - - - - ....:a._.........
-------------------- .-------•--------
Maximum Altitude _
--------- ---- ------•-------------------------------------•--
3000 m (9843 ft)
-------------
Imbalance for Single -Phase Loads 100%
..... ...... ........................... ... -....... - --------------
.----- .....-------...................................._...........................
Environment
---- ------------......---..............---
Indoor and outdoor rated
------- --------- ---------------•--------___.__-_-.-.......
Power Factor Output Range +/-1.0 adjustable
........ ........................... ............._............. -------•----•------------------------------------ ..- ----- ----...
Enclosure Type
NEMA 3R
Power Factor (full -rated power) +/-0.85
............ ............ ...............
Ingress Rating
-------------- - - - ... --- -
IP67 (Battery & Power Electronics)
------------------- ................ .......................... -...... ------ ---- - -•-----------------------
IP56 (Wiring Compartment)
Depth of Discharge . 100%
........................... ...................... ------------------ ------...._.....................-............................
Noise Level @ 1 m '
<40 dBA at 30°C (86°F)
Internal Battery DC Voltage 50V
......--- .....................-----------------....................................
-----------------------.......----------........._._.....----.._..-----......--------------- --- -- - -- -- ----------
Round Trip Efficiency' .3 89.0%
........:................................................................................---.------------------.
BACKUP ENERGY GATEWAY SPECIFICATIONS
Warranty 10 years
- ----
-- - ....._.__._._ - ---- - - - - - -- - -- - - -
---------------------_.._...----- .-•-----•----------------------------.....................--------.......................................
'Values provided for 25°C (770F), 3.3 kW charge/discharge power.
Dimensions
691 mm x 378 mm x 129 mm
2Values region -dependent.
(27.2 in x 14.9 in x 5.1 in)
3AC to battery to AC, at beginning of life.
............................`----------------..-................
......._. - -- .,.................................-.............
' *
Wei
We ght
.......... -............ ...................-----_......--------..............---------
16.44kg( 36 lbs)
------------------------ ------- .......
Disconnect Current
200 A
COMPLIANCE INFORMATION r
Enclosure Type
NEMA 3R J
- - -- ------------------------------------------------------------------------------------------------------------
Ingress Rating
IP24
SafetyUL 1642, UL 1741, UL 1973,
.......... ...... ..... ........... ....... .........................
................... --------------...............=-----......--
UL 9540, UN 38.3, IEC 62109-1,
Overcurrent Protection Breaker' 100-200 A
C22.2.107.1
IEC 62619, CSA _-
-----------..............:....... ..................
-.......................................................--- - ---- ........
--
................................ .....................................................................................
User Interface
.....................
Tesla App
Grid Standards . Worldwide Compatibility
-------- ------ -- - -- — --' -- - -- ---- - - --
....-------------------------------------------------------------------------
Connectivity
.....................................................
Wi-Fi, Ethernet, 3G°
Emissions'..
---------------------'------'-----.--------------------
AC Meter
- ------------------------------- ------ --
Revenue grade
EN 61000 Class B
Environmental RoHS Directive 2011/65/EU,
Operating Modes
Support for solar self -consumption,
WEEE Directive 2012/19/EU,
backup, load shifting, off -grid, export limits
2006/66/EC
Backup Operation
Automatic disconnect for seamless
...................................................... --------- ----•--- .................... ----------------.................................
Seismic AC156, IEEE 693-2005 (high)backup
- -
-............ - ..... -------
---------------------•---------------------------------------------------------------------------
transition
-
..-----._...-------- •-----------................-............--------....-.......--------...........................--- -
Modularity
Supports up to 10 AC -coupled Powerwalls
-----------•_-------_-------- ------
'Optional
--------------............-- ----------------
T = 5 L n