Loading...
HomeMy WebLinkAboutB17-0836 000-000-000FCX Company 3995 Ol ive. Hii-,YlLway, Orc) x 1 l� Ca_ 95966 530-533=2730_./ 530-534-1608 (Fax) Ca_Lic_ 305365 C-10, C -16,C-36 Residential Fire Sprinkler System Component List' 3 _ SPRING LOADED CHECK VALVE 4 _ WATER TEST 5 2 PULE FLOW SW I'r I 6 _ ALARM BELL BUTTE COUNTY O� comp MAY 0.42017 �` l DEVELOPMENT * C IFOR SERVICES LI NSE 0. 5 PERMIT# h0� BUTTE COUNTY DtVttbffRENT SERVICES REVIEWED FOR cn0 COD COMPLIANCE DATE BY is — RESIDENTIAL FIRE SPRINKLER SYSTEM DESIGN BY FOX COMPANY C--16 LIC. # 305365 PER REQUIREMENTS OF NFPA 13D, 2016 EDITION BLU NELSON CONST. FOWLER HOME a`L 3289 FOOTHILL BLVD. .1558 7TH.ST. 9s OROVILLE CA. 95966 OROVILLE CA. 95965 PLAN NUMBER 3272 FIRE SPRINKLED 3/17/17 WATER SOURCE IS PUBLIC UTILITY WATER PRESSURE IN STREET 60 DEDUCT METER LOSS FOR SIZE 1'' — 3 57 DEDUCT PRESSURE LOSS FROM SOURCE TO SPRINKLER CONTROL VALVE MAIN SECTION EQUIV.FT. 1-1/4'' PIPE — 50 FT. 1 GATE VALVE — 2 FT. 1 CHECK VALVE = 5 FT.. 3 90 ELBOWS = 18 FT—. 3 COUPLINGS = 3 FT. 1 TEES (RUN) = 1 FT. 0 TEES (BRANCH) 0 FT. TOTALS = 79 FT. X .0343 -- 2.71 54.29' DEDUCT HEAD LOSS FOR ELEVATION ( 20 FT. X 0.434 ) — 8.68 45.6.1 DEDUCT PRESSURE LOSS FOR PIPING FROM CONTROL VALVE TO FARTHEST SPRINKLER PIPE SECTION ONE EQUIV.FT. ---------- 1'' PIPE = 110 FT. --==45_- 0 CROSSES = 0 FT. 7 TEE(RUN) & 45 ELL = 7 FT. 3 TEES (BRANCH) = 15 FT. TOTALS = 157 FT. X .1067 —16.75 28.86 BRAND OF HEADS = GLOBE 4906 K FACTOR OF HEADS USED = 4.9 EQUIVALENT FEET CALCULATED @ 2 HEAD 2 HEAD = 26 G.P.M. FLOW ( 13 G.P.M. EA.) FRICTION LOSS `C' FACTOR = 150 G.P.M. — P.S.I. CONVERSION FORMULA.. MINIMUM PRESSURE REQ'D. FOR SPRINKLER HEAD(S) DOMESTIC LOAD OF 5 G.P.M. 1„25 IN. PIPE = 50 FT. @ 5 G.P.M. TOTAL PRESSURE REQ'D. (G.P.M./ K FACTOR)2 = P.S.I. = 7.04 P.S.I. 0.35 P.S.I. = 7.39. P.S.I. PRESSURE AVAILABLE IN SYSTEM =28.86 P.S.I. 3995 Olive Highway Phone (530) 533-2730 Oroville,.CA 95966 FOX. COMPANY Lic. No. 305365 H�7G1 THL F.Z'i2� SpTZ.Z-NKLL'72 . SYSTEM C7pLT2AT�s .UTILITY DISTRICT WATER SUPPLY: The zyztem activa.tez the 4.i4e zpninkten4 whenever: A) The FLOW SWITCH Zen.oez water 4tow .in the zyztem e...ther by a head '4.L4.ing' o44, on the INSPECTOR.TEST VALVE being opened to zZmutate a head 4t4ing o44. The zyztem can be SHUT DOWN by .turntng OFF the CONTROL VALVE CLL the bate o4 ,the FIRE RISER. TEST & FLUSH SYSTEM:. The inzpec.tor -tezt valve zhoutd be opened .MONTHLY .to tett and .6tu.6h at.he zy-6tem, activate at.anm belt and .smoke akanm.e. A .two to three minute water .6tow .test 4houkd be .au44ictent .to to s.t a.et opera-t.Lon.6 o4 the zy4tem: r _ '.'THE INCH" RESIDENTIALWIN GL ' ""no" 13 AUTOMATIC SPRINKLERS FIRE SPRINKLER CORPORATION MODEL GL4906 � ONE INCH ADJUSTABLE A f ` FLAT PLATE CONCEALED PENDENT DESCRIPTION -AND OPERATION • - The Globe Model GL4906 Residential One Inch Adjustable Concealed Pendent Sprinkler has a flat plate profile that utilizes a 3mm frangible glass ampule as the thermosensitive element. Itfeatures economy, aesthetics and the lowest allowable water flow with a nominal 1" of adjustment for easier installation. The combination of the 3mm frangible glass ampule and specially designed deflector make the Model GL4906 the ultimate in life safety and fire control. It has met the strict requirements of Underwriters Laboratories Inc. as described in UL Standard, 1626, for Residential Sprinklers for Fire Protection Service, and should be used accordingly. This sprinkler should also be installed in t �' ".accordance with the appropriate NFPA Standard 13, 13D or 13R and under the direction of the approving authorities having jurisdiction. - All that is seen at the ceiling is the 3'5/16" diameter flat ceiling plate color finished to match the specifier's exact requirements. The ceiling plate is soldered to the sprinkler's special upper support assembly in three places. Upon the application of sufficient heat, the plate falls to the floor exposing the residential pendentspray sprinkler. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass bulb to shatter. This results in water discharge which is distributed in an approved pattern. » ' TECHNICAL DATA _ • See reverse side for Approvals and Specifications. • Temperature Rating: 155°F (68°C) • Water Working Pressure Rating: 175 psi (12 Bars) • Factory tested Hydrostatically to 500 psi (34 Bars) • Maximum lowtemperature glass bulb rating: -67°F (-55'C) • Frame - bronze • Deflector - brass • Screw - brass l • Bulb seat - copper • Spring - nickel alloy ;• Seal - teflon RESIDENTIAL • Bulb - glass with alcohol based solution, 3mm size FLAT PLATE • Cover Plate -brass Y. ; CONCEALEDPENDENT • UpperEscutcheon Assembly -steel • SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER • s, TEMPERATURES - CEILING TEMPERATURE ORDINARY W04, 'F �,�8°C t RED 1p?Fs .38 CLASSIFICATION AVAILABLE SPRINKLER • N.F.P.A. MAXIMUM BULB COLOR TEMPERATURES - CEILING TEMPERATURE ORDINARY W04, 'F �,�8°C t RED 1p?Fs .38 4077AIRPARKDRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 SEPTEMBER 2011 ~' A-10 BULLETIN GL4906, REV. #1 •op` RESIDENTIAL 'A UTOMATIC,SPRINKLERS MODEL GL4906 ONE INCH ADJUSTABLE FLAT PLATE. CONCEALED PENDENT SPECIFICATIONS AND APPROVALS SIN NOMINAL GL4906 12'x 12' 13 G.P.M. - 7 P.S.I. 14' x 14' 13 G.P.M. - 7 P.S.I. 155°F (68°C) 18'x 18' 17 G.P.M. - 12 P.S.I. MODEL "K" FACTOR THREAD SIZE LENGTH FINISHES SPRINKLER WITH cULus 3/8' DIA . Quantity -Concealed Wrenches - P/N 332765 I— •Quantity -Protective Caps - P/N 332868 135*F 57°C PLATE Bright Chrome White Painted GL4906 4.9 (68 metric) 1/2" NPT 3" (7.6 cm) Bright Brass* X X Satin Chrome* Other Painted Finishes* NOTE: METRIC CONVERSIONS ARE APPROXIMATE. "FINISHES AVAILABLE ON SPECIAL ORDER. FOR PAINTED PLATES OTHER THAN WHITE, CONTACT GLOBE FOR ORDERING SPECIFICATIONS. INSTALLATION, DATA FOR FLAT AND SLOPED CEILINGS** ONE INCH ADJUSTABLE FLAT PLATE CONCEALED PENDENT MODEL MAXIMUM AREA OF MINIMUM WATER DISCHARGE & COVERAGE PRESSURES NEEDED PER SPRINKLER* GL4906 12'x 12' 13 G.P.M. - 7 P.S.I. 14' x 14' 13 G.P.M. - 7 P.S.I. 16'x 16' 13 G.P.M. - 7 P.S.I. 18'x 18' 17 G.P.M. - 12 P.S.I. 20'x 20' 20 G. P. M. - 16.7 P. S. I. NOTE: MINIMUM 9' SPRINKLER SPACING. WHITE 135°F PART # *WHEN THESE SPRINKLERS ARE USED IN NFPA 13 SYSTEMS, A 0.1 DESIGN DENSITY MINIMUM SHALL BE UTILIZED. **REFER TO PAGE 2 OF THE GLOBE RESIDENTIAL SPRINKLER INSTALLATION GUIDE FOR NFPA 13D and 13R REQUIREMENTS. ORDERING INFORMATION CROSS SECTION SPECIFY 23/4"DIA. MIN. -Quantity • Model Number • Style HOLE IN CEILING -Orifice * Temperature • Finishes desired 3/8' DIA . Quantity -Concealed Wrenches - P/N 332765 I— •Quantity -Protective Caps - P/N 332868 DEFLECTOR DROP PIN ® ® 2 3/4' MAX. SUPPORT SHELL, 17/8' ; 7/8'; MIN. CEILING COVER PIATEJ ' FLAT PLATE CONCEALED PENDENT ►1, IFIR� �PRII��ILER �Qitdl��d12 SEPTEMBER 2011 COVER PLATE SIZE WHITE 135°F PART # CHROME 135°F PART # 3 5/16" 332892 332891 GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manu- factured products found to be defective in material or workmanship for a period of one year from date of ship- ment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077AIRPARKDRIVE, STANDISH, MICHIGAN 48658 989-846-4583 1-800-248-0278 PRINTED U.S.A. FAX 989-846-9231 www.globesprinkler.com BULLETIN GL4906, REV. 91 Ir = _ QUICK RESPONSE - ' a AUTOMATIC SPRINKLERS v GL SERIES MVA UPRIGHT* PENDENT ti FIRE SPRINKLER CORPORATION • VERTICAL SIDEWALL " HORIZONTAL SIDEWALL. ' f CONVENTIONAL (OLD STYLE) DESCRIPTION.AND OPERATION y, The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass s ampule as the thermosensitive element. This provides, sprinkler " `operation approximately six times faster than ordinary sprinklers. ' rte, While the Quick -Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and , is available in various styles, orifices, temperature ratings and finishes to meet- many varying design requirements., Quick QUICK SPONSE Response Sprinklers should be used advisedly and under the UPRIGHT CONVENTIONAL r direction of approving authorities having jurisdiction. 61`'4215 The heartof Globe's GL Series sprinkler proven actuating , assembly is a hermetically sealed frangible glass ampule that contains a precisely .measured amount of fluid. When heat is f absorbed, the liquid within the bulb expands.' increasing the internal - Pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in -an approved pattern depending upon the deflector'style used. QUICK RESPONSE ' y 'TECHNICAL DATA ~ .. �. PENDENT VERTICAL . *See reverse side for Approvals and Specifications. SIDEWALL ,. •Temperature Ratings - 135°F (57°C), 155°F (68°C),. .1 75-F (79°C), 200°F (93°C), 286°F (141 °C) lob • Water Working Pressure Rating - 175 psi (12 Bars) • Factory tested -hydrostatically to 500 psi (34 Bars) I", • Maximum low temperature glass bulb rating is -67°F (-55°C) QUICK RESPONSE • Frame —bronze * Deflector - brass • Screw - brass HORIZONTAL LPC/CE • Lodgement Wire - stainless steel • SIDEWALL HORIZONTAL • Bulb seat - copper • Spring - nickel alloy Seal - teflon SIDEWALL • Bulb - glass with alcohol based solution, 3mm size ' = •SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER BULB COLOR N.F.P.A. MAXIMUM TEMPERATURES CEILING TEMPERATURE ORDINARY135°1SF INTERMEDIATE �57g€BC 175° l OOv 79°.�C�9' ORANGE/RED YELLOW/GREEN 1t7Q�,F 50'J�" 661 HIGH6°F 1:4t°C� BLUE 225° 1t5ZC: 4077AIRPARKDRIVE, STANDISH, MICHIGAN 48658 989-846-4583 • FAX989-846-9231 JULY 2012 A-20 BULLETIN GL5615, REV. #9 c QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT ®.PENDENT a VERTICAL SIDEWALL HORIZONTAL SIDEWALL • CONVENTIONAL (OLD STYLE SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH' FINISHES 2.8 (39 metric) 1/2" NPT 2 1/4" (5.7cm) 200•F 286°F cULus FM Factory Bronze 4.2 (59 metric) 1/2" NPT 2 1/4" (5.7cm) MODEL FACTOR 57•C Chrome 5.6 (80 metric) 1/2" NPT 2 1/4" (5.7cm) White Polyester 3 7.8 (111 metric) 1/2" NPT 2 1/4" (5.7cm) LH X X X Black Polyester 2.3 8.1 (116 metric) 3/4" NPT 2 7/16" (6.2cm) — METRIC CONVERSIONS ARE APPROXIMATE. 'HORIZONTAL SIDEWALL IS 2 9/16". 2 FINISHES AVAILABLE ON SPECIAL ORDER. 3 AVAILABLE AS cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. APPRnvAI S STYLE SIN K135°F HAZARD' 155•F 175°F 200•F 286°F cULus FM LPC CE NYC - DOB MODEL FACTOR 57•C 68•C 79•C 93°C 141°C MEA 101-92-E GL2815 2.8 LH X X X X X X — — — X LH X X X X X X — — — X GL5615 5.6 UPRIGHT LH/OH X X X X X X X X X X GL8115 7.8• LH/OH X X X X X X — — — X GL8118 8.1 LH/OH X X X X X X X X X X GL2801 2.8 LH X X X X X X — — — X GL4201 4.2 LH X X X X X X — — — X PENDENT GL5601 5.6 LH/OH X X X X X X X X X X GL8101 7.8• LH/OH X X X X X X X — — X GL8106 8.1 LH/OH X X X X X X X X X X VERTICAL GL5632 5.6 LH X X X X X X X — — — SIDEWALLt GL8133 8.1 LH X X X X X X — — — — GL2826 § 2.8 LH X X X X X X — — — X HORIZONTAL GL4226 § 4.2 LH X X X X X X — — — X SIDEWALL GL5626 § 5.6 LH/OH X X X X X X X — — X GI -5627a 5.6 LH/OH X X X X X — — X X — GL8127 § 8.1 LH/OH X X X X X X — — — — CONVENTIONAL GL5624 5.6 LH/OH X X X X X — — X X — (OLD STYLE) GL8125 8.1 LH/OH I X X X X X — — X X — 1SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS. §HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6" BELOW THE CEILING. °INSTALL IN ACCORDANCE TO BS5306 AND ANY OTHER RELATED DOCUMENTS. tPENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. tUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR T MIN. SPACING. OH: ORDINARY HAZARD LH: LIGHT HAZARD •1/2" NPT ORDERING INFORMATION SPECIFY GLOBES PRODUCT WARRANTY • Quantity • Model Number • Style Globe agrees to repair or replace any of its own manufactured • Orifice • Thread Sizes • Temperature products found to be defective in material or workmanship for a • Finishes desired period of one year from date of shipment. • Quantity - Wrenches - P/N 325390 (1/2"); For specific details of our warranty please refer to Price List P/N 312366 (L.O.) Terms and Conditions of Sale (Our Price List). @mom 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 FIRESPRIN LERCORPORARON 1-800-248-0278 www.globesprinkler.com JUNE 2012 PRINTED U.S.A. BULLETIN GI -5615, REV. #9 Bronze Spring Loaded Check Valve %"-2" Figure No. 3600 w/Teflon Disc. Figure No. 3600SJ w/Teflon Disc Figure No. 3615 w/Buna-N Disc Figure No. 3615SJ w/Buna-N Disc 125 PSI Saturated Steam, with TFE Disc Buna-N Disc Rated at 250 PSI 250 PSI Non -Shock Cold Water, 011, or Gas Fluid Pressure, Non -Shock W.O.G. 25 lure No. 3600 lure No. 361.5 Threaded Grinnell check.valves may be installed in vertical lines with upward flow or In any intermediate position. Do Not Use For Reciprocating Air Compressor Service. Do Not Use as a Footvalve. Q) Figure No.'3600SJ Figure No..'3615SJ Copper to Copper 777-71 IN 111h V;. t��{�}h_r�.` I ��y['�, �W}y_' ���YA,} �;'". l }h'•' R@s:IWf�i fi•.� ��.. �`a7� E � rt,. ? ,'fit_-i'.lr.. - _ ... f.i:t�`•y:t'J. ;.�.•y,}.. 0�. •'�.:-�� y�.�3?,`�c%+� ''•�1��8F�.:1t�•.A.r.R:H.I@a„ L '��? - DWi8"W6ht3 — Wel hts Nominal Size Part Speclticatlon 1. Body -Bronze ASTM B-584 Alloy C84400 2. Stem Stainless Steel ASTM A-582 Alloy S30300 3. Spring 316 Stainless Steel 4. Disc Holder Stainless Steel Type 301 5. Disc Teflon, Fig. 3600 SA. Disc Buna-N, Fig. 3615 6. Seat Fling Teflon 7. 8. Seat Screw Body End Stainless Steel ASTM A-276 Alloy S43000 Bronze ASTM B-584 Alloy C84400 Nominal Size DimensionsApprox. NNet Wt. Fig. 3600 Approx. NNet Wt. Fig. 3600SJ A B ' C 2/s 2 13/8 V/16 .4 .4 '/2 2'/16 13/6 13/16 .4 .4 2/4 2'/4 15/a 15/16 .5 .5 1 25/6 2 11/2 .8 .9 11/4 215/•6 21/6 111/16 1.2 1.3 35/,6 23/4 2 1.6 1:9 F21'12 33/4' 3'/e 1 25/16 2.4 2.7 M musicn T`l�1M=L-1NEq. Cont da - 1 800 854-1015 DIRE SPRI-NKLER. PRESSU PE GAUGES, U.S. GUAGi , AMETEK • Use on wet or dry sprinkler systems! - ♦ . • Solid brass backed! ns f z v '/,." A •NTP -L -M brass fitting; 3'/2" diameter is 'SI .21s 300 !b.lsq. in. Capacity is ins 1 - goo • .1164D1n16 60A6F R .� • . �- .. &LISTED FM APPROVEC VSa-SF POTTER (VANE TYPE WATERFLOW e FOR SMALL PIPE ALARM SWITCH WITH RETARD Foust Electric signal Company potter Electric Signal & Mfg. LTD 2081 Craig Road • P.O. Box 28480 1967 Leslie Street St. Louis, MO 63146.4161 Don Mills, Ontario, Cahada M3132M3 (314) 8784321 6 (800) 325.3936 (416) 441.1 S33 STK. NO. 1113000 U.S. PAT. NO. 3921989, CANADIAN PAT. Nb.;1009680 UL, ULC, CSFM LteTED and NYMEA ACCEPTED Service Pressure, Up to 250 PSI Minimum glow Rate for Alarm: 10 GPM Maximum Burge: 18 FPS Enclosure: Dle-cast, red enamel finish. Cover held In place with tamper resistant Wewe Contact Ratings: Two seta of SPDT (Form C) 16.0 Ample at 125/250 VAC 2.0 Amps at o -3o VDC Conduit Entrances: Two Knockouts provided for 1/2' Conduit Usags: Listed Plastic, Copper and Schedule 40 Iron Pipe Fite pipe sizes- 1', 1 1/41, and 1 1/2' Note: 8 paddles are fumishad with each unit. one for each pipe size of threaded or sweat TEE, one for V CPVC, and one for 1 1/2- polybutylene (CTS -Copper tubing size) Environnienhl Spea18eatlons: Suitable for Indoor or outdoor use with factory Installed gasket and die-cast housing NEMA 4 Rated Enclosure - use with appropriate conduit flttinq Temperature Range: 40' F/120° F (4.50 C/4V C) Caution: This device Is not Intended for epptication$ In explosive environments service Use: NFPA•13 Automatic Sprinkler NFPA-13D One at two family dwelling Residential Occupancy up to four stories NFPA•13R National Fire Alarm Code NFPA-72 OTHER PATENTS PENDING. optlonal: Cover Temper Switch, order Stk. No. 00900111 The Model VSS-SF Is a vane type viatenflow switch for use on wet sprinkler systems that use 1 `; .l 1/4', or 1 1/2' pipe elze. The unit may also bs used as a•sactional watsrflow detector on large systems. The unit contains two single pole double throw snap Action ew,Atchba and an adiustable:pneumatic retard. The switches are actuated when a flow Of 10 gallons per minute or more occurs downstream of the devloiii. The Now condition must exist for a period of time necessary to overoome the selected retard period. l INSTALLATION: These devices may be mounted In hortzontai or vertloal pipe. On horizontal pipe they should be Installed on the top side of the pipe where they wHi be sccesaible. The units should not be Installed within 8' of a valve, drain or fftting which changes the direction of the waterflow. The unit has& 1' NPT bushing for threading Into a nonconoslve TEE. See Fig. 2 for proper TEE size, type and Installation. ScrewthedevlcelntotheTEFfitNngeuehownlnFlg.2. Caremuatbetaksn to property orient the device for the direction of waterflow. The vane must not rub the Inside of the TEE or bind In any way. The stem should move freely when operated by hand. The dsvioe can also be used In copper or plastic pipe kataUtims with the. proper adapters so that the specified TEE fit" may be Installed on the pipe run. INsPECTiON AND TESTING: Check the operetlon 01 the unit by opening the Inspector' teat valve at the end of the sprinkler line or the drain and test bonitactlon, if an Inspector's teat valve Is not provided. If there are no provisions for testing the operation of the Now detection device on the system, applleatlon of the VSR-SF Is not ►eeommende8 or 'advisable Ths *uency of the inspection and testing and ita sawillied protective monitoring system should be In accordance with the applicable NFPA Codes and Standards and/or authority hsving lurtedfctlon (manufacturer recommends quarterly or more frequently). CAUTION: There are 8 paddies fumished with each unit. These paddles have raised lettering that shows the pipe size and type of TEE that they are to be used with. The proper paddle nuM be used. The screw that holds the paddle must be securely tightened. MKT. "lilO O - REV t PAGE 1 Of 2 PRINTED IN USA MF(j. #g400808 • 3/05 ®"PO- BELLSER' • ii ® PBA -AC &PBD- DC Potter Electric Signal Company Potter Electric Signal & Mfg. LTD .2081 Craig Rd., P.O. Box 28480 1967 Leslie Street St. Louis, MO 63146 Don Mills, Ontario, Canada M3B2M3 (314)878-4321 / (800) 325-3936 (416) 441-1833 UL LISTED, FM APPROVED Sizes Available: 6", 8", and 10" Voltages Available: 24VAC 120VAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31:2) Polarized Service Use: Fire Alarm General Signaling 'Burglar Alarm Environment: Indoor or Outdoor Use (See Note 1) -400 to 150°F (outdoor use require '•weatherproof backbox) Termination: 4 No. 18 AWG stranded wires Finish: Red powder coating 6" BELL SHOWN Optional: Model BBK-1 weatherproof backbox These vibrating type bells. are designed for.use as fire, burglar, or.: general signaling devices.7hey':have low power consumption and high decibel ratings: The unit mounts on a standard 4" square electrical boz for.indoor use, or on a model BBK-1 weatherproof backbox for outdoorrapplications. ALL DC BELLS ARE POLARIZED AND HAVE BUILT-IN TRANSIENT PROTECTION: SIZE VOLTAGE MODEL NO STOCK NO. CURRENT (MAX) TYPICAL d8 10 FT. MINIMUM dB 10 FT. 6 12VDC PBD126 1706012 .12A 85 75 8 12VDC PBD128 1708012 .12A 90 75 10 12VDC PBD1210 1710012 .12A 92 75 6 24VDC PBD246 1706024 .06A 87 ' 75 8 24VDC PBD248 1708024 .06A 91 79 10 24VDC PBD2410 1710024 .06A 94 79 6 24VAC PBA246 1806024 .17A 91 75 8 24VAC PBA248 1808024 .17A 94 75 10 24VAC PBA2410 1810024 .17A 94 75 6 120VAC PBA1206 1806120 .05A 92 82 8 120VAC PBA1208 1808120 .05A 99 82 10 120VAC PBA12010 1810120 .05A 99 85 Weatherproof backbox model BBK-1 Stk. No. 1500001.' Notes: 1. Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is •30° to 150°F. 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. PRINTED IN USA MKT. #8850001- REV K PAGE 1 OF 2 MFG. #5400776 - 4/94 9600-KLINGERMAN STREET * P.O. BOX 3365 - SOUTH EL MONTE, CA 91733 * USA O TEL: 626.444.0541 *.FAX: 626.444.3887 E-MAIL: info@afcon.oi-g' * www.afcon.org M -4 ' 1 r . CPUC STEEL - COPPER y • t + #510 #511 #514 (1° 1 ° ° Patented ° o Installation Instructions = Install on CPUC pipe as alhanger and/or restrainer per their engineering sheets. Some are additionally listed for use for use with steel and copper pipe. 4 :x #510 & #514 install on top, bottom or side of beam. #511 install on top or bottom of beam. #513 Anstall on top or side of beam. #515 & 519 install on .side of beam. Required fasteners furnished: #904 for #515 C.R\'.C. Max. Hanger #905 for #510 thru #514 Pipe Size, Spacing 3/4 — — — 5 1/2 1 -------------- 6 1 114 ------------ 6 1/2 I1'2--— 7 2 --------- ---- Y ` 2 1/2 ------------- 9 3 -------------- 10