Loading...
HomeMy WebLinkAboutB17-0881 000-000-000GENEF,AL NOTES 1. S-YSTEM DESIGN AND INSTALLATION SHALL COMPLY WITH NFPA 13D-2016 EDITION, ALL LOCAL CODES AND THE CITY OF CHICO FIRE DEPARTMENT REQUIREMENTS. 2. SYSTEM DESIGN BASIS: HYDRAULICALLY MOST DEMANDING 2 SPRINIG>_ERS. 3. WATER TO SUPPLY INFORMATION: STATIC - 83 PSI RESIDUAL - 57 PSI RESIDUAL FLOW - 2307 GPM SOURCE: CAL. WATER SERVICE CO. TEST DATE - 1/27/2010 LOCATION - 5W CORNER OF SKWAY HEGAN LANE 4, ALL PIPE SHALL BE: UNDERGROUND - SCHEDULE 40 PVC ABOVE GROUND EXPOSED - COPPER -L OVERHEAD IN ATTIC - CPVC 5. MANUFACTURERS OF RESIDENTIAL Sf=,RINKLERS PUBLISH INFORMATION REGARDING THE SPACING OF THEIR SPRINKLERS WITH RESPECT TO HEAT PRODUCING DEVICES (FIREPLACES, RANGES, OVENS, HEATING VENTS, WATER HEATERS, FURNACES, ETC.) WHETHER OR NOT ALL HEAT PRODUCING DEVICES ARE SHOWN ON THE PLAN PROPER MINIMUM DISTANCES MUST BE MAINTAINED. SEE HEAT SOURCE CHART. (o. THE MINIMUM DISTANCE BETWEEN ANY 2 RESIDENTIAL SPRINKLERS SHALL NOT BE LESS THAN 8 FEET. 7. THE MAXIMUM DISTANCE BETWEEN ANY 2 RESIDENTIAL SPRINKLERS ON THIS PROJECT IS HYDRAULICALLY LIMITED TO leo FEET. SPRINKLERS SHALL NOT EXCEED 8 FEET FROM ANY WALL. 8. THE MINIMUM DISTANCE A SPRINKLER CAN BE LOCATED FROM A WALL IS 4 INCHES. S. INSTALLATION OF ALL RESIDENTIAL SPRINKLERS WILL BE IN STRICT COMPLIANCE WITH THE MANUFACTURERS INSTALLATION GUIDE. 10. PROVIDE PROPER SIGNAGE PER CRC 313.3.1 AND NFPA 131D AND ALL APPLIGABLE LOCAL CODES. 01 CONCEALED RESiC,-)ENTIAL PENDENT SPRINKLER RECESSED RESIDENTIAL PENDENT SPRINKLER QR UPRIGHT SPRINKLER NEW 5pRIN :LER PIPE ® SYSTEM RISER �— CHANGE IN PIPE ELEVATION 12 HYDRAULIC REFERENCE POINT --�� PIPE HANGER OCR SPACING OF VARIOU5 PIPING MATERIAL5 PIPING PIPE KE ORDINARY 3/4 if '/4/4 TEMP. 12:�4/ liMATE-RIAL5 3 it COPPER ro 8 8 10 10 10 12 GPVG LATERAL DISTANCE FROM THE 51DE6 OF A WOOD OR COAL BURNING STOVE 31-611 1'-0" 9 10 1000 5 1'-6" 0'-9" LATERAL DISTANCE FROM A WALL OVEN 120° 01_C3II 5 55 -1 13 03 SCHEDULE 40 $ 10 5TEEL * 12 12 15 15 15 1 E� THREADA13LE THNWALL * 12 12 12 12 12 12 POLYBUTYLENE (GIST 3 3 .4 4.5 E�'5 2'-0" 1'-0" POLYBUTYLENE (IP5) * 4 -,,5 5 1f -e" LATERAL DISTANCE FROM THE SUFAC-E OF ISSUES AND REVISIONS: No. DATE I DESCRIPTION ,pROTECT/'O \ FIRE �p �pt� W� p~ CLASSIFlCAMN �p C-16 Z o J LICENSE N0, 6 �'4 F OF C AL`F� Hill$ lim �I�IV�II�VtlII I VVV U110 1 Qi uuEm iuuuuul 11MIluumumul� u JuMu li�uu uliuuuuu �du�ud �u�uuu��uou MMIdu all MUM 'k T I m ka ne er Spa c ine Ncte5 1. ALL LENGTHS SHOWN ARE THE MAXIMUM RECOMMENDED DISTANCE BETWEEN HANGERS EXPRESSED IN FEET. 2. PROVIDE A HANGER WITHIN ro INCHES OF ALL DROPS TO SPRINGLER HEADS WHEN USING CPVC PIPE. 3. STEEL PIPE 15 NOT ALLOWED IN SIZES LESS THAN 1 INCH, 4. INDICATE INFORMATION THAT IS NOT AVAILABLE. 5. CTS = COPPER TUBE SIZE. 6. IPS IRON PIPE SIZE. 7. DENOTES LOCATION OF PIPE HANGER. HARDENED PEX HEAD SELF THREADING SCREW 15 FURNISHED HARDENED HEX HEAD SELF WITH THE HANGER AND 15 THE THREADING SCREW IS FURNISHED MINIMUM FASTENER 51ZE ®I I® WITH THE HANGER AND IS THE ACCEPTABLE T'I'P. .MINIMUM FASTENER SIZE ACCEPTABLE TYP. CPUC DOUBLE FASTENER PLAN SYMBOL PLAN SYMBOL STRAP TYPE HANGER CPVC STAND-OFF HANGER 1=1GUR 24 CPVC HANGER FIGURE 20 - CPVC HANGER o �Toa�O `�oa�0 HANGER IDETAIL� P WATER METER V 10201 I E'JTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR CODE COMPLIANCE A �F\VkE F''oT � o UALIFORbiIA 2 f,',-? n x 1 � 1/4" = 1'-0,. 4 0 4 8 NOTE: THIS PLAN IS FOR HYDROLIC REFERENCE ONLY. ALL UNDERGROUND NO SCALE INSTALLATION IS BY OTHERS. SCALE IN FEET PENDENT HEADS TO HAVE CHROME ESCUTCHEONS 0 1' 2' 4' CARTWRIGHT RESIDENCE JOB # 1272 SPRINKLERS SYM, FINISH TEMP. QTY, SCALEGWH ,.. DIAMOND M FIRE PROTECTION 710 SKYWAY AVE. DATE: 5-4-17 SCALE: AS NOTED ", CHICO, CA DRAWN PYi EDC TOTAL SPRINKLERS THIS DRAWING PROJECT SUPERINTENDENTi 2400 CATTLE DRIVE ROAD APPROVALSI ■ CITY HEAD COUNT = 31 ❑ INSURER CORNING, CA 960:21 ❑ OWNER DRAWING NO, LIC. # C-16 463104 LSP _ �I TELEPHONE I (530) 824-3456 FAX , (530) 824-3456 COVER SHEET 11�' 1 SHEET 1- [IF 2 PROX11"IIT1' OF= SPRINKLERS TO 14E ,4T SOURCES ORDINARY INTERMED. TEMP. TEMP. LATERAI, DISTANCE FROM THE SIDES OF AN OPEN OR RECESSED HEARTH FIREPLACE 31-0" 1'-0" RADIAL D I STANCE FROM A RECESSED HEARTH FIREPLACE B, -01I 3'-0" LATERAL DISTANCE FROM THE 51DE6 OF A WOOD OR COAL BURNING STOVE 31-611 1'-0" LATERAL DISTANCE FROM THE SURFACE OF A KITCHEN RANGE 1'-6" 0'-9" LATERAL DISTANCE FROM A WALL OVEN 11_611 01_C3II LATERAL DISTANCE FROM THE SURFACE OF NOT AIR FLUES LATERAL DISTANCE FROM UNINSL'L ATED HEATING DUCTS LATERAL DISTANCE FROM UNINSULATED WATER PIPES LATERAL DISTANCE FROM THE EDGES OF A CEILING MOUNTED HOT AIR DIFFUSER 2'-0" 1'-0" LATERAL DISTANCE FROM T;�E SIDES OF A WALL MOUNTED HOT AIR DIFFUSER 2'-0" 1'-0" LATERAL DISTANCE FROM THE FRONT OF A WALL MOUNTED HOT AIR DIFFUSER 31-011 1f -e" LATERAL DISTANCE FROM THE SUFAC-E OF A WATER HEATER OR FURNACE 01_oll 0'-3" LATERAL DISTANCE FROM A 250 WATT, OR LESS, LIGHT FIXTURE 014011 0'-3" LATERAL DISTANCE FROM A 250 WATT TO 499 WATT LIGHT FIXTURE 1'-0" 0140" ka ne er Spa c ine Ncte5 1. ALL LENGTHS SHOWN ARE THE MAXIMUM RECOMMENDED DISTANCE BETWEEN HANGERS EXPRESSED IN FEET. 2. PROVIDE A HANGER WITHIN ro INCHES OF ALL DROPS TO SPRINGLER HEADS WHEN USING CPVC PIPE. 3. STEEL PIPE 15 NOT ALLOWED IN SIZES LESS THAN 1 INCH, 4. INDICATE INFORMATION THAT IS NOT AVAILABLE. 5. CTS = COPPER TUBE SIZE. 6. IPS IRON PIPE SIZE. 7. DENOTES LOCATION OF PIPE HANGER. HARDENED PEX HEAD SELF THREADING SCREW 15 FURNISHED HARDENED HEX HEAD SELF WITH THE HANGER AND 15 THE THREADING SCREW IS FURNISHED MINIMUM FASTENER 51ZE ®I I® WITH THE HANGER AND IS THE ACCEPTABLE T'I'P. .MINIMUM FASTENER SIZE ACCEPTABLE TYP. CPUC DOUBLE FASTENER PLAN SYMBOL PLAN SYMBOL STRAP TYPE HANGER CPVC STAND-OFF HANGER 1=1GUR 24 CPVC HANGER FIGURE 20 - CPVC HANGER o �Toa�O `�oa�0 HANGER IDETAIL� P WATER METER V 10201 I E'JTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR CODE COMPLIANCE A �F\VkE F''oT � o UALIFORbiIA 2 f,',-? n x 1 � 1/4" = 1'-0,. 4 0 4 8 NOTE: THIS PLAN IS FOR HYDROLIC REFERENCE ONLY. ALL UNDERGROUND NO SCALE INSTALLATION IS BY OTHERS. SCALE IN FEET PENDENT HEADS TO HAVE CHROME ESCUTCHEONS 0 1' 2' 4' CARTWRIGHT RESIDENCE JOB # 1272 SPRINKLERS SYM, FINISH TEMP. QTY, SCALEGWH ,.. DIAMOND M FIRE PROTECTION 710 SKYWAY AVE. DATE: 5-4-17 SCALE: AS NOTED ", CHICO, CA DRAWN PYi EDC TOTAL SPRINKLERS THIS DRAWING PROJECT SUPERINTENDENTi 2400 CATTLE DRIVE ROAD APPROVALSI ■ CITY HEAD COUNT = 31 ❑ INSURER CORNING, CA 960:21 ❑ OWNER DRAWING NO, LIC. # C-16 463104 LSP _ �I TELEPHONE I (530) 824-3456 FAX , (530) 824-3456 COVER SHEET 11�' 1 SHEET 1- [IF 2 SYSTEM DESIGN DATA 5EDROOMS 2 8 3 HAZARD CLASSWICATIDN 2 MOST HI-DRAULICALLY DEMANDING 5PR(NKLERS HYDRAULIC / DESIGN DENSITY N/A GPM/SQ FT 2 A. S. @ 25rJ SQ/FT HEAD ALLLOVANCES 5 GPM AREA OF APPLICATION 2 HEADS REQUIREMENTS REMENTS 312-19 GPM AT 39.-139 PSI AT GITl' TYGO "TYFRB" 5RA55 UPRIGHT WATER SUPPLY INFORMATI❑N; STATIC PRESSURE. 83 PSI, RESIDUAL PRESSURE: 51 PSI WITH 2307 GPM FLOWING TEST TAKEN AT, SW CORNER OF SKWAY E PECAN LANE TEST TEST TAKEN BY. CAL. WATER SERVICE CO. DATE, 1/21/2010 APPROVALS REQUIRED, CITY OF CNICO FIRE DISTRICT 1' CPVC TO PVC UNDERGROUND R«R DETAIL NO SCALE f.: i LED LED LEDD .. ., f h SD In Jz;2 4, L , € 4 .t rcd .... ...... ........ f 1 1 HE -ADS Cr I fl - 10 - 9 .:........................ 4i • t \"• "'•. \ , `BKYLIGH I j fl40! .� SGHT {,SD HATCHED AREAS INDICATE HEAT SOURCES - SEE CHART NO A/S ALLOWED O o .-, of c) V 2-7 6-t 4-9 10-3 CD C— C) j.:_ ...... ........... 1 1 0-5 15-3 0-6 8-2' $Y 3 s + ff[ .< l NOTE: NO A/S REQ, IN CLOSETS THAT D❑ NOT EXCEED 24 SQ, FT, PER NF"PA 13D 8.3.3 OR BATHROOMS LESS THAN 55 SQ. FT, PER NF -PA 8.3.2 C-16 z LEL . 60104 _. _„ -?JTtE COUNTY DEVELOPMENT SERVICES REVIEWED FOR _ CODE COMPLIANCE OF;T-� f BY �. UND R ROUND AND R Ov HE AD F I F I N LAN 1. SEE SHEET Fi=-i FOR GENERAL NOTES 4 DETAILS. 2. ALL CEILING HEIGHTS A5 NOTED ON KLAN, 4 0 4 8 3. ALL FIFING 16 Gl=Vc U.O.N. SCALE IN FEET ISSUES AND REVISIONS: PENDENT HEADS T❑ HAVE CHROME ESCUTCHEONS No. DATE DESCRIPTION 0 1' 2' 4' �❑B # 1272 P�aTEcro� �-0» ,.'-�� ���' CARTWRIGHT RESIDENCE 0 M FIREPpOjn SPRINKLERS SYM, FINISH TEMP, QTY. SCALE GRAPH ""'' DIAMOND M FIRE PROTECTION 710 SKYWAY AVE. DATE: 5-4-17 U� p~ CLASSIFICATION Z ,Y�i CHICO, CA SCALE AS NOTED 'S J C-16 0 T � DRAWN BY, EDC * ucsE No. * 463104 2400 CATTLE DRIVE ROAD y: 1t APPROVALS: ■ CITY HEAD COUNT = 31 Sj4T O���tr PROJECT SUPERINTENDENT: "" CORNING, ❑INSURER £ ALF _ •�...� ' ,,.. FAQ CA 96021 o OWNER DRAWING NO. OF C LIC. # C-16 463104 FP -2 TOTAL SPRINKLERS THIS DRAWING — TELEPHONE ; (530) 824-3456 FAX I (530) 824-3456 FIRE SPRINKLER PLAN SHEET 2— OF 2 30 TYCO Lr --ii CONCEALED RESIDENTIAL SSP 15r�o 1/2" ORIFICE 1/2" NFT K=4,9O S.I.N. TY2524 TYGO "TYFRB" 5RA55 UPRIGHT 200" 1/2" ORIFICE 1/2" Nf=T K=5.60 6.1.N. TY3131 PRE—FABBED TRUSSES 1' CPVC TO ,. FIRE SPRINKLER SYSTEM O6' ELEC. BELL U d U 11 SPARE CHB, w/ WRENCH 1' FLOW SWITCH I ACCESS PANEL BY G.C. I j 1' SWING CK, VA, Z u RISER LOCATED IN A > EXTERIOR WALL ��N U --~COPPER / CPVC TRANS COUP. 1' CONTROL VALVE TO DOMESTIC I I ® SERVICE BY PLUMBER 1' CONTROL VALVE 0 1', x 60-0 PVC / COPPER TRANS COUP, PVC UNDERGROUND R«R DETAIL NO SCALE f.: i LED LED LEDD .. ., f h SD In Jz;2 4, L , € 4 .t rcd .... ...... ........ f 1 1 HE -ADS Cr I fl - 10 - 9 .:........................ 4i • t \"• "'•. \ , `BKYLIGH I j fl40! .� SGHT {,SD HATCHED AREAS INDICATE HEAT SOURCES - SEE CHART NO A/S ALLOWED O o .-, of c) V 2-7 6-t 4-9 10-3 CD C— C) j.:_ ...... ........... 1 1 0-5 15-3 0-6 8-2' $Y 3 s + ff[ .< l NOTE: NO A/S REQ, IN CLOSETS THAT D❑ NOT EXCEED 24 SQ, FT, PER NF"PA 13D 8.3.3 OR BATHROOMS LESS THAN 55 SQ. FT, PER NF -PA 8.3.2 C-16 z LEL . 60104 _. _„ -?JTtE COUNTY DEVELOPMENT SERVICES REVIEWED FOR _ CODE COMPLIANCE OF;T-� f BY �. UND R ROUND AND R Ov HE AD F I F I N LAN 1. SEE SHEET Fi=-i FOR GENERAL NOTES 4 DETAILS. 2. ALL CEILING HEIGHTS A5 NOTED ON KLAN, 4 0 4 8 3. ALL FIFING 16 Gl=Vc U.O.N. SCALE IN FEET ISSUES AND REVISIONS: PENDENT HEADS T❑ HAVE CHROME ESCUTCHEONS No. DATE DESCRIPTION 0 1' 2' 4' �❑B # 1272 P�aTEcro� �-0» ,.'-�� ���' CARTWRIGHT RESIDENCE 0 M FIREPpOjn SPRINKLERS SYM, FINISH TEMP, QTY. SCALE GRAPH ""'' DIAMOND M FIRE PROTECTION 710 SKYWAY AVE. DATE: 5-4-17 U� p~ CLASSIFICATION Z ,Y�i CHICO, CA SCALE AS NOTED 'S J C-16 0 T � DRAWN BY, EDC * ucsE No. * 463104 2400 CATTLE DRIVE ROAD y: 1t APPROVALS: ■ CITY HEAD COUNT = 31 Sj4T O���tr PROJECT SUPERINTENDENT: "" CORNING, ❑INSURER £ ALF _ •�...� ' ,,.. FAQ CA 96021 o OWNER DRAWING NO. OF C LIC. # C-16 463104 FP -2 TOTAL SPRINKLERS THIS DRAWING — TELEPHONE ; (530) 824-3456 FAX I (530) 824-3456 FIRE SPRINKLER PLAN SHEET 2— OF 2