Loading...
HomeMy WebLinkAboutB17-0880 063-040-128BUTTE COUNTY AREA DEPARTMENT OF DEVELOPMENT SERVICES 4 INSPECTION CARD MUST BE ON JOB SITE 24 Hour Inspection Line (IVR) : 530.538.4365 (Cut off time for inspections is 3pm) Development Services cannot guarantee inspections on the date requested Office: 530.538.7601 Fax: 530.538.7785 www.ButteCounty.net/dds Permit No: B 17-0880 Issued: 5/9/2017 APN: 063-040-128 Address: 4989 SCHOTT RD, FOREST RANCH Owner: HOUAR, MICHAEL Permit Type: ELECTRICAL Description: AC DISCONNECT FOR EXISTING SOLAR Flood Zone: None SRA Area: Yes Front: Centerline of Road: Rear: SRA: Street: AG: Interior Total Setback from Centerline of Road: ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING Inspection Type IVR INSP DATE Setbacks 131 Foundations / Footings III Pier/Column Footings 122 Eufer Ground 216 Masonry Grout 120 Setbacks 131 Do Not Pour Concrete Until Above re Sign d Pre -Slab 124 Gas Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing 149 Underfloor Ducts 319 Shear Transfer 136 Under Floor Plumbing 412 Under Slab Plumbing 411 Blocking[Underpining 612 Tiedown/Soft Set System 611 Do Not Install Floor Sheathing or Slab Until Above Signed Shearwall/B.W.P.-Interior 134 Shearwall/B.W.P.-Exterior 135 Roof Nail/Drag Trusses 129 417 Manometer Test Do Not Install Siding/Stucco or Roofing Until Above Signed Rough Framing 153 Rough Plumbing 406 Rough Mechanical 316 Rough Electrical 208 4 -Way Rough Framing 128 Gas Piping House 403 Gas Test House 404 Shower Pan/Tub Test 408 Do Not Insulate Until Above Signed Permit Final 802 Electrical Final 803 Mechanical Final 809 Plumbing Final 813 Fire Sprinkle Test or Final 702 Swimmi g Pools Inspection Type IVR INSP DATE T -Bar Ceiling 145 Stucco Lath 142 Swimmi g Pools Setbacks 131 Pool Plumbing Test 504 Gas Test 404 Pre-Gunite 506 Pre -Deck 505 Pool Fencing/Alarms/Barriers 503 Pre -Plaster 507 Manufactured Homes Setbacks 131 Blocking[Underpining 612 Tiedown/Soft Set System 611 Permanent Foundation System 613 Underground Electric 218 Sewer 407 Underground Water 417 Manometer Test 605 Continuity Test 602 Skirting/Steps/Landings 610 Coach Info Manufactures Name: Date of Manufacture: Model Name/Number: Serial Numbers: Length x Width: Insignia: t iffa-lg--- Public WorKs Final 538.7681 Fire Department/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final "PROJECT FINAL - rroject t inal is a t-ermicate ol Uccupancy Tor (KesiGennal unlyr PERMITS BECOME NULL AND VOID I YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A I YEAR RENEWAL 30 DAYS PRIOR TO EXPIRATION Butte County Department of Development Services PERMIT CENTER 7 County Center Driv6, Oroville, CA 95965 Main Phone 530:538.7601 Fax 530.538.7785 wmv. bu ttecou n t y. neuaa ELECTRIC SERVICE OUESTIONAIRE Jn order to insure that you get -timely assistance and the type of permit you need, we request that all applicants for electrical service upgrades, retags, 2 nd services, etc. answer the following questions'. 1. What is the service for? cv., C e- 2. Are there any structures on the parcel? YC -1 3. Will this be for commercial use? No 4. Is this a mobile/modular home? If yes, will the service be on a pole for the mobile? MO 5. Is this a 2 d service on the parcel? 0 6. Have you contacted PG&E? 7. What size (amps) is the service? _'2ZQk 8. Is this a 3 phase service? 9. Are you doing any other work? Uj e, a'e-'_' ndC4,!, S' eQ191' C"'�c If you need additional room to answer'these questions, please use the area below or the back of this page: -T�\e_w OJ( Ct. so-xple 'Lo -t,-.Q Z� br-ej�ke-,-_ L/ e'ls 2—GO Thank you. Page I of I Revised '7.20.2015 0 and the manufacturers installation instructions. Other carbon monoxide alarm and detection devices as recognized in NFPA 720 are also'acceptable. Carbon monoxide alarms required by Sections'R315.1 and R315.2 shall be installed in the following locations: 1. Outside of each separate dwelling unit sleeping area in the immediate vicinity of the bedroom(s).- 2. On every level df'a dwelling unit including basements. R315.3.1 Multiple-purpbse alarms: Carbon monoxide alarms combined with smoke alarms shall comply with Section R315, all applicable standards, and requirements for listing and approval by the Office of the State Fire Marshal, for smoke alarms. Butte County's Interpretation of 2010 CRC, Sections 314 & 315 for Smoke Alarms & Carbon Monoxide Alarms: Where alterations, repairs or additions exceeding $1,000 in valuation, existing dwellings shall be retrofitted with smoke alarms and those that have attached Rarap-es or fuel -burning appliances shall have carbon monoxide alarms installed. Existing smoke alarms can be replaced with dual function alarms for Smoke and Carbon Monoxide and in most cases will co mply with the aforementioned code requirements for Carbon Monoxide Alarms. DECLARATION OF INSTALLATION UNDER THE PENALTY OF PERJURY As Owner/Contractor, I/we affirm and declare under the penalty of perjury, under the laws of the State of California, by our signatures below as Owner/Contractor, that Itwe will comply prior to final inspection with Items A & B as specified herein: A. Both Owner/Contractor have read and clearly understand the aforementioned 2010 California Residential Code (CRC) Carbon Monoxide Alarm requirements. B. Both Owner/Contractor are responsible for installing Carbon Monoxide Alarms prior to final inspection as per the aforementioned building code and maintaining such installation. Smoke Alarms will also be installed prior to final inspection as per the 2010 ��CRC, and Carbon Monoxide ala are now installed in the following locations: 1q:)V 1664 ! 4 t4 r 14, Owners name (print):. M 1' 6 ha U r,,e- Owner's signature: Date: Contractors name (prino: -flv &W06&1ea3 4A �SLB License: Contractor's signature: Date: ProjectAddress: �-Jfk' Permit KANEW - WEBS 1TE\Bui1djn_g\Bui1ding Forms& Documents\,Approved2011 forms -handouts and on list\Declaration for Smoke & Carbon Monoxide Detectors DB 1-0 1 2. 1 3.12.dok: Page 2 of 2 3 240 VAC OWNER JOBSITE (5) EnphaseAC Battery B -1200-LL-1-USOO-RFO 280 Rated Output Power: 270VA, 6011Z Nominal Output Current: 1. 13A (45) 240 WATT Utflity Interactive Inverters Michael Houar Enphase M250 -60-240-S22 4989 Schott Rd, CEC Model: Enphase M250-60-2LL-S2x (-ZC)(-NA)(240V) 8 - # 12 AWG THWN-2 CU 2 - #8 THW`N-2 CU Engage Cable CEC-Inverter Efficiency: 96.5% 1 - # 12 AWG T14WN-2 CU (N) Forest Ranch, CA 95942 240VAC, 1�, 60Hz I - #8 AWG THWN-2 CU E.G.C. APN: 063-040-128 Wall -Mount Bracket Voltage and Phase Sensing Neutral (Gnd to be continuous) I - #8 THWN-2 CU E.G.C. E.G.C. Ground Listed to UL 1741 V LFMC Conduit 48 VDC Max Input Voltage (Run behind array) Integr�ted G.E.C.Ground (Existing) 1.25" LMFC Conduit PV Circut: Module Module Module Battery Enclosure (Vented) 200A W/ 200A Main, 120/24OV, 10 (Run Along Equipment Wall) (9) SolarWorld SW270 Mono Black (Grounded) CONTRACTOR t 270W Modules Microin�cnc' North State Solar Energy 20A LZ PO Box 899 20A Forest Ranch, CA 95942 Junction Box Lie.# B813508 PV Circut: Module Module Module NEMA 3F, UL 1741 L= (10) SolarWorld SW270 Mono Black (At Array) Phone: 530.342.7304. 270W Modules Fax: 530.725.4363 T Microinverter I - #8 AWG THWN-2 CUE. G.C. PV Circut: Module Module Module 2OA (10) SolarWorld SW275 Mono Black L= 275W Modules I" LFMC Conduit Dedicated PV System PROJECT DETAILS Utility AC Disconnect Switch (5) New Enphase AC Batteries PV Circut: Module Module Module added to existing 12.5KW solar (16) SolarWorld SW270 Mono Black 270W Modules 60A CH DG222NRB Dedicated PV System PV roof mount system. All L= wiring is AC. 240 VAC (5) EnphaseAC Battery B -1200-LL-1-USOO-RFO 280 Rated Output Power: 270VA, 6011Z Nominal Output Current: 1. 13A Enphilse AC CEC Efficiency: 97.3% 2 - #8 THW`N-2 CU Engage Cable Mounted on Enphase Energy I - #8 THWN-2 CU Neutral And Bare #6 AWG Wall -Mount Bracket I - #8 THWN-2 CU E.G.C. E.G.C. Ground Part# BMW -161N -B (God to be continuous) (Existing) 1.25" LMFC Conduit 200A W/ 200A Main, 120/24OV, 10 (Run Along Equipment Wall) (5) Juncti on Box 2P -100A Existing Customer Loads 20A LZ 20A 20A 2 - # 12 AWG THWN-2 CU I - # 12 AWG THWN-2 CU (N) 20A I - #8 AWG THWN-2 CUE. G.C. 2OA (Gnd to be continuous) I" LFMC Conduit Dedicated PV System Utility AC Disconnect Switch Cutler -Hammer 60A CH DG222NRB Dedicated PV System 2 -POLE, 240VAC, NEMA 3R AC Agregate Panel (Visible Blade Type, Lockable, 120/240 VAC, 125Aj NEMA 3R Main Service Line Side Labeled, Accessible 24/7) Main Lug O�ly PV Connection (4) 2P -20A PV Circut Breakers Via NSI Polaris Lugs (1) 2P -20A New Circuit*Breaker (Batteries) Allowed Per CEC 240.21 (D), (Located at Array) 705.12 (A), and 230.82 (6)