Loading...
HomeMy WebLinkAboutB17-1024 030-080-008BUTTE COUNTY AREA DEPARTMENT OF DEVELOPMENT SERVICES 1 INSPECTION CARD MUST BE ON JOB SITE 24 Hour Inspection Line (IVR) : 530.538.4365 (Cutoff time for inspections is 3pm) Development Services cannot guarantee inspections on the date requested Office: 530.538.7601 Fax: 530.538.7785 www.ButteCounty.net/dds Permit No: B 17-1024 Issued: 5/30/2017 APN: 030-080-008 ' Address: 1641 SWEEM ST, OROVILLE Owner:. IRVIN JOHN.E & PHYLLIS J Permit Type: SOLAR -ROOF -RES Description: Solar pv. roof mount 7.2kw ' Flood Zone: None SRA Area: No SETBACKS forAinneno- AG- SRA- PW Front: Centerline of Road: Rear: SRA: Street: AG: Interior Total Setback from Centerline of Road: ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING Insvection Type IVR INSP DATE Setbacks 131 Foundations / Footings 111 Pier/Column Footings 122 Eufer Ground 216 Masonry Grout 120 Setbacks 131 Do Not Pour Concrete Until Above are Signed Pre -Slab 124 Gas Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing 149 Underfloor Ducts • 319 . Shear Transfer 136 Under Floor Plumbing 412 Under Slab Plumbing 411 Blockin nde inin 612 Tiedown/Soft Set System 611 Do Not Install Floor Sheathing or Slab Until Above Signed Shearwall/B.W:P.-Interior • 134 ; ShearwallB.W.P.-Exterior 135 Roof Nail/Drag Trusses 129 417 Manometer Test Do Not Install Siding/Stucco or Roofing Until Above Signed Rough Framing 153 Rough Plumbing '406 Rough Mechanical -316 Rough Electrical 208 4 -Way Rough Framing .128 Gas Piping House 403 Gas Test House 404 Shower Pan/Tub Test 408 ' Do Not Insulate Until Above Signed' .Permit Final. 802 Electrical Final. .803 --.- 803_ -Mechanical Mechanical Final 809 = Plumbing Final 813 Fire Sprinkle Test or Final 702 Swimming Pools Inspection Type IVR INSP DATE T -Bar Ceiling 145 Stucco Lath 142 Swimming Pools Setbacks 131 Pool Plumbing Test 504 Gas Test 404 Pre-Gunite . 506 Pre -Deck 505 Pool Fencing/Alarms/Barriers 503 Pre -Plaster 507 Manufactured Homes Setbacks 131 Blockin nde inin 612 Tiedown/Soft Set System 611 Permanent Foundation S stem 613 . Underground Electric 218 Sewer 407 Underground Water 417 Manometer Test 605 Continuity Test. 602 Skirtin /Ste s/Landin s '610 Coach Info Manufactures Name: Date of Manufacture: del Name/Number: ial Numbers: n th x Width:- rLe i•nia: 41 Public Works Final 538.7681. . Fire De artment/CDF - 538.6226 Env.. Health Final 538.7281 Sewer District Final "PROJECT FINAL *Project Final is a Certificate of Occupancy for (Itsiden4al ly) PERMITS BECOME NULL AND VOID 1 YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PA FORA 1 EAR RENEWAL 30 DAYS PRIOR TO EXPIRATION Butte C Department of Development Servic� PERMIT CENTER 7 County Center Drive,,Oroville, CA 95965 Main Phone (530) 538-7601 Fax (530) 538-7785 www.butteggunty.net/dds Declaration of Installation for Smoke Alarms and Carbon Monoxide Alarms FORM NO DBI -01 The newly adopted 2013 California Residential Code requires the installation of Carbon Monoxide Detectors in dwelling units and in sleeping units within which fuel -burning appliances are installed and in dwelling units that have attached garages. The policy for Carbon Monoxide Alarms in Butte County states: "Any permit obtained in which the value of work exceeds $1000 associated with a Residential Group R Dwelling Unit or Sleeping Unit shall conform to the following 2013 California Residential Code requirements for Smoke and Carbon Monoxide Alarms (Section R314 & R315)." 2013 California Residential Code requirements for Carbon Monoxide Alarms: R315.1 New construction: An approved carbon monoxide alarm shall be installed in dwelling" units and in sleeping units within which fuel -burning appliances are installed and in dwelling units that have attached garages. R315.1.2 Power supply: For new construction required carbon monoxide alarms -shall receive their primary power from the building wiring where such wiring is served from a commercial source and shall be equipped with a battery back-up. Alarm wiring shall be directly connected to the permanent building wiring without a disconnecting switch other than as required for over - current protection. Exceptions: 1. In dwelling units where there is no commercial power supply the carbon monoxide alarm may be solely battery operated. 2. In existing dwelling units a carbon monoxide alarm is permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. R315.1.3 Interconnection. Where more than one carbon monoxide alarm is required to be installed within the dwelling unit or within a sleeping unit the alarm shall be interconnected in a manner that activation of one alarm shall activate all of the alarms in the individual unit. Exception: 1. Interconnection is not required in existing dwelling units where repairs do not result in the removal of wall and ceiling finishes, there is no access by means of attic, basement or crawl space, and no previous method for interconnection existed. R315.2 Where required in existing dwellings: Where a permit is required for alterations, repairs or -additions exceeding one thousand dollars ($1,000), existing dwellings or sleeping units that have attached garages or fuel -burning appliances shall tie provided with a carbon monoxide alarm in accordance with Section R315.1. Carbon monoxide alarms shall only be required in the specific dwelling unit or sleeping unit for which the permit was obtained. R315.2.6 Alarm requirements: No person shall install, market, distribute, offer for sale or sell any carbon monoxide device in the State of California unless the device and instructions have been approved and listed by the State Fire Marshal. Pagel of 2 Revised 7.20.2015 Carbon monoxide alarms required by Sections R315.1 and R315.2 shall be installed'in the. following locations: 1. Outside of each separate dwelling unit sleeping area in the immediate vicinity of the bedroom(s). 2. On every level of a dwelling unit including basements. R315.1.5 Multiple -purpose alarms: Carbon monoxide alarms combined with smoke alarms shall"comply with Section R315, all applicable standards,. and requirements for listing and approval by the Office of the, State Fire Marshal, for smoke alarms. Butte County's Interpretation of 2013 CRC, Sections 314 & 315for Smoke -Alarms & Carbon Monoxide Alarms: Where alterations, repairs or additions exceeding $1,000 in valuation, existing dwellings shall be `retrofitted with smoke alarms and those that have attached garages or fuel -burning appliances shall have carbon monoxide alarms installed. Existing smoke alarms can be replaced with dual function alarms for Smoke and Carbon Monoxide and in most cases will comply with the aforementioned code requirements for Carbon Monoxide Alarms. DECLARATION OF INSTALLATION UNDER THE PENALTY OF PERJURY As Owner/Contractor, Uwe affirm and declare under the penalty of perjury, under the laws of the State of California, by our signatures below as Owner/Contractor, that I/we will comply prior to final inspection with Items A & B as specified herein: A. Both Owner/Contractor have read and clearly understand the aforementioned 2010 California Residential Code (CRC) Carbon Monoxide Alarm requirements. B. Both Owner/Contractor are responsible for installing Carbon Monoxide Alarms prior to final inspection as per the aforementioned building code and maintaining such ` installation. Smoke Alarms will also be installed prior to final inspection as per the 2010 CRC. Smoke and Carbon Monoxide alarms are now installed in the following locations: / .S sH a/l.c.. 4 Ari 4;0 -v // &J" o*1S I-ra4- 4 t A / 9,1--+ "-7 '11411W411'p C/ rie-yr Owner's name (print): Jo, A/ �/Z w Ov Owner's signature ,aa Date: 711zll 7 Contractor's name (print): CSLB License: 7S 0 Contractor's signature: Date: %ILL '7 Project Address: ld�11 Permit#: 7'/02-�( Page 2 of 2 Revised 7.20.2015 CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND . _1 20/240 VAC (4) 10 AWG PV WIRE NONE (1) 8 AWG BARE COPPER 2 • SINGLE PHASE NONE (1) 8 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV. ,. 'SERVICE (1) 8 AWG THHN/THWN-2 4 EXISTING CONDUIT EXISTING WIRING EXISTING WIRING METER #: • EXISTING 100A OPG&E 1007638996 SUB PANEL - UTILITY. ^� _ GRID (2) RELOCATED EXISTING 1P BREAKERS 100A MAIN ^� • "�^ " _ PANEL r Ttu • k-sv{'G-. - - (HOT BUSS) ^ FACILITY ^� 4 , - LOADS ^.- • ^� SOLAREDGE , I EXISTING 90A EXISTING (N) SUN RUN TECHNOLOGIES: SE6000 SUB -FEEDER .-: WIRING CENTRON 4G (240V) W/ -ER-US ORA=US BREAKER ^ 3 METER 3 6000 WATT INVERTER 2 JUNCTION BOX 1 PV MODULES < s OR EQUIVALENT REC SOLAR: REC290TP2 BLK ^ ^ L Ac .L (25) MODULES Dc OPTIMIZERS WIRED IN (1) SERIES OF (13) - NEUTRAL •-=� _� LL OPTIMIZERS AND (1) SERIES OF (12) eur10 GFPD D OPTIMIZERS FACILITY 35A PV aaouNo - 250V METER SOCKET" LOAD RATED DC - SOLAREDGE POWER OPTIMIZER BREAKER AT 125A CONTINUOUS & ' DISCONNECT WITH RAPID P300 OPPOSITE END 240V METER SHUTDOWN & AFCI OF BUSBAR 200A, FORM 2S r CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4) 10 AWG PV WIRE NONE (1) 8 AWG BARE COPPER 2 3/4" EMT OR EQUIV. (4) 10 AWG THHN/THWN-2 NONE (1) 8 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV. , (2) 8 AWG THHNrrHWN-2 _ (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 4 EXISTING CONDUIT EXISTING WIRING EXISTING WIRING EXISTING WIRING MODULE CHARACTERISTICS P300 OPTIMIZER CHARACTERISTICS: REC SOLAR: REC290TP2 BLK: 290 W MIN INPUT.VOLTAGE: 8 VDC OPEN CIRCUIT VOLTAGE: 38.8.V MAX INPUT VOLTAGE: 48 VDC MAX POWER VOLTAGE: 32.1 V MAX INPUT-ISC: 10 ADC SHORT CIRCUIT CURRENT: 9.58 A MAX OUTPUT CURRENT: 15 ADC SYSTEM .CHARACTERISTICS -.INVERTER 1 SYSTEM SIZE: 7250 W. SYSTEM OPEN CIRCUIT VOLTAGE: 13 V SYSTEM OPERATING VOLTAGE: 350 V MAX ALLOWABLE DC VOLTAGE: 500 V SYSTEM OPERATING CURRENT: 20.7 A SYSTEM SHORT CIRCUIT CURRENT: 30 A NOTES TO INSTALLER: 1. 13 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE, 2. ADD 35 AMP PV BREAKER TO MAIN PANEL. - Q BAAINI PANIGI 11AANI1 IFA(.TI IPGP• 71NIQ(Y1 4., INMAINPANEL: RELOCATE (2) 1 P BREAKERS TO EXISTING 100A SUB -PANEL. 5. PV BREAKER TYPE: UBIZ235. 6-12 AWG BARE' 5/16'-18 SS BOLT COPPER WIRE SS SPLIT LOCK WASHER (TORQUE TO 16 FT -LBS) n \ SNAPNRACK GROUND LUG 1 / r / ( BONDING CHANNEL NUT RAIL SS BONDING PINS NOTE: • ALL HARDWARE IS INCLUDED FROM MANUFACTURER • A MINIMUM OF ONE GROUND LUG IS TO BE INSTALLED ON EVERY CONTINUOUS ROW OF MODULES • GROUNDING LUG MAY BE INSTALLED IN EITHER RAIL CHANNEL GROUNDING LUG MAY BE INSTALLED SO GROUND WIRE IS PARALLEL OR PERPENDICULAR TO RAIL' • ENSURE SPLIT LOCK WASHER IS INSTALLED ON TOP OF COPPER WIRE SNAPNRACK GROUNDING SCALE: NTS sunrun- CA CL #750184 1227 STRIKER AVENUE, SUITE 260, SACRAMENTO, CA 95834 PHONE 916.949.7885 FAX 916.285.9154 CUSTOMER RESIDENCE: JOHN IRVIN ' 1641 SWEEM ST, OROVILLE, CA 95965., TEL. (530) 533.7631 APN #: 030-080-008-000 PROJECT NUMBER: 105R-641 I RVI DESIGNER: 805.234.2795 TYLER YAGER DRAFTER: TYLER YAGER SHEET ELECTRICAL REV: A 5/22/2017 PAGE PV -4.0 ROOF TYPE AR -01 COMP SHINGLE AR -02 COMP SHINGLE AR -03 COMP SHINGLE DI -AR -01 -SCALE: 3/16"=I' -O'; PITCH: 17° AZIM: 90° ATTACHMENT FLASHED L FOOT. SEE PEN D01 FLASHED L FOOT. SEE PEN D01 FLASHED L FOOT. SEE PEN D01 ROOF HEIGHT ROOF FRAME SONG EXPOSURE MATERIAL SINGLE STORY ATTIC WOOD SINGLE STORY ATTIC WOOD SINGLE STORY ATTIC WOOD FRAME TYPE FRAME SIZE MAX FRAME SPAN SONG ROOF EDGE ZONE MAX RAIL SPAN- MAX RA OVERHA RAFTER 2X6 8'-0" 24" 5'-3" 6'-0" 2'-0" RAFTER 2X6 12'-5" 24" 5'-3" 4'-0" 1'-4" RAFTER 2X6 8'-0" 24" 5'-3" 6'-0" 2'-0" D2 - AR -02 - SCALE: 3/16" = 1'-0" PITCH: 17° AZIM: 180° DESIGN CRITERIA MODULES: REC SOLAR: REC290TP2 BLK MODULE DIMS: 65.94" x 39.25" x 1.5" MODULE CLAMPS: Portrait: 8.2" - 16.4" Landscape: 4.9" - 9.8" MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 0 PSF SPEED: 110 MPH 3 -SEC GUST. LAG SCREWS: 5/16"x3.5": 2.5" MIN EMBEDMENT NOTE: INSTALLERS TO VERIFY RAFTER SIZE, SPACING AND SLOPED SPANS, AND NOTIFY E.O.R. OF ANY DISCREPANCIES BEFORE PROCEEDING. sunrun CA CL #750184 1227 STRIKER AVENUE, SUITE 260, SACRAMENTO, CA 95634 PHONE 916.949.7665 - FAX 916.285.9154 CUSTOMER RESIDENCE: JOHN IRVIN 1641 SWEEM ST, OROVILLE, CA 95965 TEL. (530) 533-7631 APN 0:030-080.008-000 PROJECT NUMBER: 105R-6411RVI DESIGNER: 805.234.2795 TYLER YAGER: DRAFTER: TYLER YAGER SHEET LAYOUT REV: A 5/22/2017 PAGE - _ -­PV-3.0=_ fi �1 TABLE OF CONTENTS SCOPE OF WORK : GENE`;L NOTES LEGEND ANBBREVIATIONS PAGE # DESCRIPTION • SYSTEM SIZE: 7250W DC, 6000W AC • ALL WORK SHALL COMPLY WITH 2016 CEC, 2016 CBC, MUNICIPAL CODE, AND SOLAR MODULES PV -1.0 �- COVER SHEET SE SERVICE ENTRANCE • MODULES: (25) REC SOLAR: REC290TP2 BILK ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS._ - RAIL PV -2.0 SITE PLAN • 'INVERTER(S): PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2016.CEC. PV -3.0 LAYOUT (1) SOLAREDGE TECHNOLOGIES: SE6000 (240V) W/ -ER-US • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2916 CEC. Mp MAIN PANEL — - OR A -US • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY PV -4.0 ELECTRICAL • RACKING: SNAPNRACK SERIES 100 UL; FLASHED L FOOT., GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITK',690.35. SEE PEN D01. . MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. SP SUB -PANEL STANDOFFS & PV; 5.0 SIGNAGE • (25) SOLAREDGE TECHNOLOGIES: P300 OPTIMIZERS. • rRTER CONFORMS TO AND IS LISTED UNDER UL 174: "' - FOOTINGS • DER UL 2703 RACKING CONFORMS TO AND IS LISTED UN - CHIMNEY • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). LC PV LOAD CENTER k • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. • 9.58 AMPS MODULE SHORT CIRCUIT CURRENT.F ATTIC VENT s. • 14.96 AMPS DERATED SHORT CIRCUIT CURRENT (690.8 (a)-& 690.8 (b))., SM SUNRUN METER FLUSH ATTIC VENT : y S DEDICATED PV METER 0 PVC PIPE VENT INVERTER(S) WITH ® METAL PIPE VENT INV INTEGRATED DC DISCONNECT AND AFCI ® T -VENT AC AC.DISCONNECT(S) . t r SATELLITE DISH u DC Q DC DISCONNECT(S) FIRE SETBACKS COMBINER B n -- CB ER_ OX HARDSCAPE • A t _ F INTERIOR EQUIPMENT —'PL PROPERTY LINE IC J SHOWN AS DASHED SCALE: NTS sunrun A AMPERE AC t ' ALTERNATING CURRENT t AFCI ARC FAULT CIRCUIT INTERRUPTER CA CL #750184 AZIM AZIMUTH ` VICINITY MAP COMP COMPOSITION 1217 STRIKER AVENUE, SUITE 260, SACRAMENTO, CA DC, DIRECT. CURRENT 95834 (E)., EXISTING P FAX IICkS corner' f' FAX sls.zass154 �r EXT EXTERIOR CUSTOMER RESIDENCE:. FRM FRAMING JOHN IRVIN INT INTERIOR 1641 SWEEM ST, OROVILLE, CA ! LBW LOAD BEARING WALL 95965 MAG MAGNETIC _ 70 MSP MAIN SERVICE PANEL - TEL. (530)5337631 APN #: 030-080-008-000 .. ;c (N) NEW . . } -•-� '`^tPROJECT NUMBER: NTS NOT TO SCALE Shippee-6411 RVI FAB ' ' • . l 05R y_ =vOC� r - PRE- PRE -FABRICATED `• V ' DESIGNER: 805:234.2795 PSF POUNDS PER SQUARE FOOT TYLER YAGER PV _ PHOTOVOLTAIC 1641 Sweem Street = t. TL TRANSFORMERLESS Q J r ,6]' TYP TYPICAL DRAFTER: OrowilleTYLER YAGER' c • .V VOLTS {rte.--'�"�.., - -- - r•-- fez _, tNildlifeA7ea+ - _ � 1 _ ( W WATTS SHEET ! 't REV NAME DATE COMMENTS COVER SHEET t. r ,�t j �� Y - REV: A 5/22/2017 PAGE PV -i .O n '_t ' 4 •.r .. ' INVERTER 1 OWARNING ELECTRICAL SHOCK HAZARD KIWERNIN, URCE LABEL LOCATION:, INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, AT EACH TURN, ABOVE AND NOTES AND lSPECIFICATIONS: - • • SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE CEC 2016 AND NEC 2014 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED - • 20.7 I BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. 1115.1• if • 350 • SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. _ • 500 � . LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING 30 I METHOD AND SHALL NOT BE HAND WRITTEN, UNLESS PORTIONS OF LABELS OR MARKINGS ARE VARIABLE, OR THAT COULD BE SUBJECT TO CHANGES, SHALL DO NOT TOUCH TERMINALS. • . BE PERMITTED TO BE HAND WRITTEN AND SHALL BE LEGIBLE. , .BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. � LABEL LOCATION: TERMINALS ON LINE AND'LOAD PER CODE(S): CEC 2016.69.0;a](G)(3), 690.31(G)(4), NEC 2014:690.31(G)(3), INVERTER(S), DC DISCONNECT(S)� uc> , - • LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTA�t T f ENVIRONMENT 690.31(G)(4), NEC 2011: 690.31(E)(3), 690.31(E)(4), IFC 2012:605.11.1.4 PER CODE(S): CEC 2016: 690.53, NEC 2014: 690.53, NEC INVOLVED. SIDES MAY BE ENERGIZED IN • SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY. THE OPEN POSITION- LABEL LOCATION: , INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). x PER CODE(S): CEC 2016:690.17(E), NEC 2014:690.17(E),' ' NEC 2011: 690.17(4) . WARNING 2011.690.53 , SIGNS AND LABELS; UNLESS OTHERWISE SPECIFIED. • DO NOT COVER EXISTING MANUFACTURER LABELS. - Mmomilw Nim a r moo O + 31.25 _ LABEL LOCATION:' _ i I , ' ' . ' 1: LABEL LOCATION: UTILITY SERVICE ENTRANCE/METER, OR AS REQUIRED BY, LOCAL AHJ. AC BREAKER AND AC DISCONNECT ELECTRICAL SHOCK HAZARD PER CODE(S): CEC 2016: 690.12, NEC 690.56, NEC 2014:,690.12, NEC 690,56, (Inside or front of panel] • IFC 2012: 605.11.1 IF GROUND -FAULT IS INDICATED ' gar1 v ,, ALL NORMALLY GROUNDED ' ' ' -- CONDUCTORS MAY BE mom • •- ., e - UNGROUNDED AND ENERGIZED - + LABEL LOCATION: 'LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF t' + sunrunINVERTER(S), ENPHASE ENVOY ENCLOSURE (IF INTERCONNECTION. APPLICABLE). PER CODE(S): CEC 2016: 690.54, NEC 2.014: 690.54, NEC PER CODE(S): CEC 2016: 690.5(C), NEC 2014: 690.5(C), 2011: 690.54 d NEC 2011:690.5(C) &WARNING' &WARNING -. {� CA CL'#750184 - - ^ ELECTRICAL SHOCK HAZARD DUAL POWER SUPPLY THE DC CONDUCTORS OF THIS SOURCES• UTILITY GRID _ i� ' .144 227 AVENUE, SUITE 260, SACRAMENTO, CA PHOTOVOLTAIC SYSTEM ARE ) FAX9 s916.949.7885 s9 54 AND PV SOLAR ELECTRIC L UNGROUNDED AND MAY BEf + ENERGIZED SYSTEM CUSTOMER RESIDENCE:. LABEL LOCATION: ;LABEL LOCATION:' JOHN IRVIN '-- • 1641 SWEEM ST, OROVILLE, CA INVERTER(S), DC DISCONNECTS. UTILITY SERVICE METER AND MAIN . 1 PER CODE(S): CEC 2016:690.35(F), NEC SERVICE PANEL. 95965 2014: 690.35(F), NEC 2011: 690.35(F) PER CODE(S): CEC 2016: 705.12(D)(3), NEC 2014: 705.12(D)(3), NEC 2011: TEL. (530) 533-7631 APN #: 030-080-008-000 .. - 705,12(D)(4) , a PROJECT NUMBER: &WARNING &WARNING t Y' ' 105R-6411RVI i ` ( a r 805.234.2795 ` t _ , .. INVERTER OUTPUT CONNECTION PHOTOVOLTAIC SYSTEM' - DESIGNER: TYLER PAGER DO NOT RELOCATE THIS,.. _ • COMBINER PANEL „ _ OVERCURRENT:DEVICE -DO,NOT ADD LOADS DRAFTER: + LABEL LOCATION: LABEL LOCATION:— i`" TYLER PAGER ADJACENT TO PV BREAKER (IF PHOTOVOLTAIC AC COMBINER (IF SHEET APPLICABLE). APPLICABLE). PER CODE(S): CEC 2016: PER CODE(S): CEC 2016: { . SIGNAGE 705.12(D)(2)(3)(b), NEC 2014: 705.12(D)(2)(3)(c), NEC 2014: 705.12(D)(2)(3)(b), NEC 2011: 705.12(D)(7) 705.12(D)(2)(3)(c), NEC 2011: 705.12(D)(4) REV: A 5/22/2017 41 ' �_ PAGE PV -5.0