Loading...
HomeMy WebLinkAboutB17-1054 047-740-030BUTTE COUNTY AREA DEPARTMENT OF DEVELOPMENT SERVICES 4 INSPECTION CARD MUST BE ON JOB SITE 24 Hour Inspection Line (IVR) :530.538.4365 (Cut off time for inspections is 3pm) Development Services cannot guarantee inspections on the date requested Office: 530.538.7601 Fax: 530 Permit No: B 17-1054 Issued: 5/30/2017 APN: 047-740-030 Address: 13998 LINDBERGH CIR, CHICO Owner: AMINALROYAE FARIBA Permit Type: SOLAR ROOF -RES Description: 20.79 KW roof mount solar, 225 amp panel www.butteuounty.neyaas Flood Zone: A SRA Area: No Front: Centerline of Road: Rear: SRA: Street: AG: Interior Total Setback from Centerline of Road: ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING Insipection TVDe E Setbacks 131 . Foundations / Footings 111 Pier/Column Footings 122 Eufer Ground 216 Masonry Grout 120 Setbacks 131 Do Not Pour Concrete Until Above are Sign d Pre -Slab 124 Gas Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing 149 Underfloor Ducts 319 Shear Transfer 136 Under Floor Plumbing 412 Under Slab Plumbing 411 /moi- t5 w 5F 4,415-b Tiedown/Soft Set System 611 Do Not Install Floor Sheathing or Slab Until Above Signed Shearwall/B.W.P.-Interior 134 Shearwall/B.W.P.-Exterior 135 Roof Nail/Drag Trusses 129 Manometer Test 605 Do Not Install Siding/Stucco or Roofing Until Above Signed Rough Framing 153 Rough Plumbing 406 Rough Mechanical 316 Rough Electrical 208 4 -Way Rough Framing 128 Gas Piping House 403 Gas Test House 404 Shower Pan/Tub Test 408 Do Not Insulate Until Above! ped Finals - Ins ection Type IVR INSP DATE T -Bar Ceiling 145 Stucco Lath 142 Plumbing Final 813 Fire Sprinkler Test or Final 702 Swimmin Pools Setbacks 131 Pool Plumbing Test 504 Gas Test _` 404 Pre-Gunite 506 Pre -Deck 505 Pool Fencing/Alarms/Barriers 503 Pre -Plaster 507 Manufactured Homes Setbacks 131 Blockin nder inin 612 Tiedown/Soft Set System 611 Permanent Foundation System 613 Under round Electric 218 Sewer 407 Underground Water 417 Manometer Test 605 Continuity Test 602 Skirtin Ste s/Landin s 610 Coach Info Manufactures Name: Date of Manufacture: Model Name/Number: Serial Numbers: Length x Width: Insignia: Permit Final 802 Electrical Final 803 Mechanical Final 809 Plumbing Final 813 Fire Sprinkler Test or Final 702 Public Works Final 538.7681 Fire De artment/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final "PROJECT FINAL - -rrulect rmas is a %-erancate of occupancy ror tttesiaennai unly) PERMITS BECOME NULL AND VOID 1 YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A 1 YEAR RENEWAL 30 DAYS PRIOR TO EXPIRATION DocuSign Envelope ID: B3497F3A-82DC-4791-BF51-05ED94151719 and the manufacturer's installation instructions. Other carbon monoxide alarm and detection devices as recognized in NEPA 720 are also acceptable.' Carbon monoxide alarms required by Sections R315.1 and R315.2 shall be Installed in the following locations: r 1: Outside of each separate dwelling unit sloping area in the Immediate vicinity of the bedroom(s). 2: On every level of a dwelling Unit including basements. R316.3.1 Multiple -purpose alarms: Carbon monoxide alarms combined with smoke alarms shall comply with Section R315, all applicable standards, and requirements for listing and approval by the Office of the State Fire Marshal, for smoke alarms. Butte County's Interpretation of 2010 CRC, Sections 314 & 315 for Smoke Alarms & Carbon Monoxide Alarms: Where alterations, repairs or additions exceeding $1,000 in valuation, existing dwellings shall be retrofitted with smoke alarms and those t..tl at have attached garages or fuel-burnine appliances shall have carbon monoxide alarms installed. Existing smoke alarms can be replaced with dual function alarms for Smoke acrd Carbon Monoxide and ,itt most cases will comply with the aforementioned code requirements for Carbon Monoxide Alarms. DECLARATION OF INSTALLATION UNDER THE PENALTY OF PERJURY As Owner/Contractor, lhnie affirm and declare'under the penalty of perjury, under the laws of the State of California, by our signatures below as Owner/Contractor, that Itwe will comply prior to final Inspection with Items A & B as specified herein: ' A. Both Owner/Contractor have read and clearly understand the aforementioned 2010 California Residential Code (CRC) Carbon Monoxide Alarm requirements. B. Both Owner/Contractor are responsible for installing Carbon Monoxide Alarms prior to final inspection as per the aforementioned building code and maintaining such installation. Smoke Alarms will also be installed prior to final inspection as per the 2010 CRC. Dke and Carbon Monoxide plarms are now installed in the following locafions: ,- Owner's name (print): `Bahram Kiassat owner s�signat 5/25/2017 SolarCity Corporation DBA Tesla Energy 888104 Contractor's name (print): CSLB License: ? Contractor's signature: 4 Date: .7 - Project Project Address: 13998 Lindbergh_ Circle Chico CA 95973 Permit #: Page 2 of 2' ago -OND (N) /6 GEC TO (E) UFER AT PANEL Panel Number. MPU Inv 1: DC Ungroundod INV 1-0)saAREocE�l 000w�s-ze-u u® ,A-(66)SolorCty Standard �C325 ' 1MTH IRREVERSIBLE CRIMP Meter Number. 106771&57 Inv 2: OC Ungrounded inrrter; 1000011, 240V, s�.iiCO-•/linffad"D6co and 2fl AF13 PV Module; 325W, 306.5 PTC, 40MM, Blk Frm, MC4, 600v, ZEP, 96-C Underground Service Entrance Tie -In: Supply Side ConneeU INV 2-(t)WbR �, /cit 2aor »�i.s>r owow. / bPoo and M A:n Voc 69.6 Vpmos 57.6 INV 3 Isc AND Imp ARE SHOWN IN THE DC SLANGS IDENTIFIER 225A MAIN SERVICE PANEL (E) 225A/2P MAIN CIRCUIT BREAKER Inverter 1 CUTLER -HAMMER BRYANT 4 Disconnect 3 (N) 125A Load Center _ 1 SOIAREDGE e A 54E B 1100. SE10000A-US-IB-U MP4,MP5: 1x14 C 6OA/2P Ir x.w T-------------- --------- /�Lex P12,MP13:1x8------- ----------Ecc --«. P10,MP12: 1x10__ _____________ (t)CaWR at 3/r EMT SdarCity . Inverter 2 SEI 0000A US-ZB-U oc JLL�pl' MP 15: 1x1 _ c6c t �� i 600./ 1 u (� r----------------------- -- ---- 5 ccc 6 ---------- IN I.P. i - ; " o� 1 9 w MP Ems' TILMGLE PHASE r ____-------___--- 6cc 1 U11171Y SFRNLE i - L_ --- � T----- --- -- ---w . t i -----------� -- -- E. ---------------------- - -- ---- 6cc -- -----'---- ---J i . (1)C.&H IOt 3/r EMT . i i = MAX V (2)BSaD SUPPLY AS SER UG AT MIN ILMN SIDE MBE ' CWANED SHALL NOT BE UW Fm Ra: 6C 4/0-2/0 PiscFp Cam . Main 4/0-2 Tap 2/0-5 - CONIIECTIOIL =()K EO W MEANS SHAU. BE SUITABLE WAVENT AND SHALL BE RATED PER NEC . - g (1)an1ER�,AIOR7a� � aan6m AC Dinmraact Tera,( 240Voa. PosNle, NEMA Nt -(1) Oxon sited g . G-, % Xawp Dutr M DNS IRMA 1, 3R . #=UK apapo��R I- Kilt � -(2) Frwe 11W 230V."t Po'G wBAC76ED) OCP MM MU NOR SIMI IT BE DISCLOSED N WOE OR N BR4wo - larW, E1R7S�A 120/240V. NFMA 3R load C-alinAtBRM CjPe.2 Spam PART TO OTHERS OVIWE THE RECMGNYS R. TINN-2 Mad - (I)AWG O6, S.Od Mare Copper GLC IL TIME -2 Red -AAC f JAWG I& THMI-2 Mods - - (i)AWG b, Sand Bae Upper GEC ©14f-(1)AIIC A Dffl-2 Red O R DMI -R MdtewVIRAL. v -p ^240 VAC .IMP -84. (1)ANC n0. TNAN-2 Mhne MWTRAL Vmp -240 VAC tmp=42 AAC Z' PERMSM OF saARaTY NG A.71!7)J-?.. Osm .. Epic ... - ((1) W!44 Nil'. 1.-)X (N ........ R, TIMI -2 61od -(1 )ANC 16, kaki Bae Capper GM 12 THW-2 Red ... .0..... - AMC (B,, 1NMF-L. R,em .. ECC ....-(1 )CanOtlt, (DC.?/4� E11?......... . (1)ANG A DW --Z Wo* -(1 )AIIC A Ulid Elan Capper GEC ®�(1)AG A TIMI• -2, Red..... 'Imp . R TXW-2. We MINIM VmP ^240 VAC Imps B4 AAC /B,, Saod Bae. C•Pve.LEC...-{t)Cadtll, KH;, ........ (1)ANC n0. 1NNM-2, %Mite , NEUTRAL Vmp -240 VAC -42 AAC „.,,,,-,(I)ANC �,. TH( Z.Oem„E6C...-(t)Cad%N, O ......... ... ................ .. 0�1)ANC /10. sand Bare capper EDC .vmP .................... VmP ^350 VDC Imp= 8.16 ADC /(0, TW!/1H91H2.lipn, EDC-{1)f:?WwP. Kif:.3/4' ENT ........ aa«'WEM>uL- THE DDaRMMMHEIM -- JB=9597215 00 CWANED SHALL NOT BE UW Fm Ra: „. a�f0p1;,DFA51 AN BOUT Or YONE EXCEPT SMARCITY NC. MM MU NOR SIMI IT BE DISCLOSED N WOE OR N ZS Comp V4 w Flashing -Insert PART TO OTHERS OVIWE THE RECMGNYS n0. w Nre. 600V, Mod ORCumnoN, Dun N COWRECIMIN NI1X THE SALE AND USE of THE RESICHVE � 66 SolarCit Standord C325 SOLARCrTr MW M b NT THE �IaTIDI MU.. Z' PERMSM OF saARaTY NG SOLAREDGE E1000OA-US-ZB-U BAHRAM KIASSAT 13998 LINDBERGH CIR CHICO, CA 95973 (2)SMC,WILROR Bmf „. a�f0p1;,DFA51 DC PV PweBoa4ttnar/0D ;41400A:IIP n0. w Nre. 600V, Mod VOC• = 500 VDC Is[ a 15 ADC O['�(2)ANC RA-(1)AWG /10. Sand Bare Capper EOC Vmp 350 VDC Imp- 1283 ADC (i)ArIG iid Pv Nie; sooV.'Bloah v«• =500 ddc isc'=15 aDc . O �(I)AW /10. Sand Bme CWW EDC 350 VDC Imp= 7.33 ADC A TIM♦ -2 Mod V«• = 500 VDC I= = JO ADC A TMF2 Rad Vmp = 350 VDC Imp- 16,49 ADC ......... ... ................ .. 0�1)ANC /10. sand Bare capper EDC .vmP .................... VmP ^350 VDC Imp= 8.16 ADC /(0, TW!/1H91H2.lipn, EDC-{1)f:?WwP. Kif:.3/4' ENT ........ ........ 6 .. ............. r-� (2)ANC /10. PV Ntra 600V, Blod vert• = SOd ..VOC 11w.- Voc• VDE Is[ = 15 ADC /I0. 2. 500 ®�(1)ABC n0. Sand Baro Capps. fOC VmD =350 VDC Imp= 10.66 ADC Pa. TXYf-2 Rid Vmp =350 VDC imp=1283 ADC Rid , na z.(reen, ac -(1)w aft, gt. 5/' i�cdr.......... -Z [� (2)ANG pd PV Wk% cauv.'810* "' Voc• = 5Ud "VDC ix ='15"' ADC A HW M v«• = 500 VDC 30 5 0.(1 )AMD n0. Sand Bae Copper FbC .VmP 350 VDC Imp= 8.25 ADC ADC - wa-2. Rid Imp- A RINN-2 Rd Vmp =350 VDC Imp=18.5 ADC n0. 11MH2 Bled Voc- -5w (2)AM /10. w Mire. 600V..0Iod....: 6 k (I )ANC n0. Sam Ban Capps EDc Voc'.=500 ..VDC Ix 15 ADC VmD ^350 VDC Imp- flu ADC n0 Rod Vmp - 350 VDC Imp -14.66 ADC - J10.OESDIPTI ........................................... I................ L BAHRAM KIASSAT RESIDENCE 0690E Austin Schoenbaum 21.45 KW PV ARRAY r\SoiarCity. p4k4yDt G650) PAGE MAIC sm JIM DATE• PV 7 T:(850) BSB-i�� 83B-,o2D THREE LINE DIAGRAM C 7/20/2017 (Bale)-sn-amrcr65-24w)....da�l,� ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE AC ALTERNATING CURRENT BLDG BUILDING CONIC CONCRETE DC DIRECT CURRENT EGC EQUIPMENT GROUNDING CONDUCTOR (E) EXISTING EMT ELECTRICAL METALLIC TUBING FSB FIRE SET—BACK GALV GALVANIZED GEC .GROUNDING ELECTRODE CONDUCTOR GND GROUND HDG HOT DIPPED GALVANIZED I CURRENT Imp CURRENT AT MAX POWER Isc SHORT CIRCUIT CURRENT kVA KILOVOLT AMPERE kW KILOWATT LBW LOAD BEARING WALL MIN MINIMUM (N) NEW NEUT NEUTRAL NTS NOT TO SCALE OC ON CENTER . PL PROPERTY LINE POI POINT OF INTERCONNECTION PV PHOTOVOLTAIC SCH SCHEDULE S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT . Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT LICENSE CA # 888104 C-10 MODULE GROUNDING METHOD: ZEP SOLAR I AHJ: Butte County UTILITY: Pacific Gas and Electric Company 1. THIS SYSTEM IS GRID—INTERTIED VIA A UL—LISTED POWER—CONDITIONING INVERTER. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. 3. A NATIONALLY—RECOGNIZED TESTING LABORATORY SHALL LIST ALL EQUIPMENT IN COMPLIANCE WITH ART. 110.3. 4. WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A SIGN WILL BE PROVIDED WARNING OF THE HAZARDS PER ART. 690.17. 5. EACH UNGROUNDED CONDUCTOR OF THE MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PHASE AND SYSTEM PER ART. 210.5. 6. CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH ART. 250.97, 250.92(B). 7. DC CONDUCTORS EITHER DO NOT ENTER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER ART. 690.31(E). 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. 9. MODULE FRAMES SHALL BE GROUNDED AT THE UL—LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL LISTED GROUNDING HARDWARE. 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE BONDED WITH EQUIPMENT GROUND CONDUCTORS. . GENERAL NOTES 1. ALL WORK TO BE DONE TO THE 2016 CALIFORNIA BUILDING CODE, 2016 CALIFORNIA PLUMBING CODE, AND THE 2016 CALIFORNIA RESIDENTIAL CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE AS AMENDED BY THE 2016 CALIFORNIA ELECTRIC CODE. CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER JB -9597215 0 0 CONTAINED SHALL NOT BE USED FOR THE PROPERTY PLAN BENEFIT OF ANYONE EXCEPT SOARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert PART TO OTHERS OUTSIDE THE RECIPIENTS STRUCTURAL VIEWS ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES THE SALE AND USE OF THE RESPECTIVE (66) SolarCity Standard #SC325. SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER PERMISSION OF SOARCITY INC. SOLAREDGE SE10000A—US—ZB—U BAHRAM KIA.SSAT 13998 LINDBERGH CIR CHICO, CA 95973 APN:047740030000 VICINITY MAP BAHRAM KIASSAT RESIDENCE 21.45 KW PV ARRAY PAGE NAME:- COVER AMECOVER SHEET INDEX PV1 COVER SHEET PV2 PROPERTY PLAN PV3 SITE PLAN PV4 STRUCTURAL VIEWS PV5 STRUCTURAL VIEWS PV6 UPLIFT CALCULATIONS PV7 THREE LINE DIAGRAM Cutsheets Attached REV BY DATE COMMENTS REV A NAME I DATE COMMENTS Austin Schoenboum SHEET: REV. DATE- PV ATEPV 1 b 7/2/2017 ;SolarCit v 3055 Clearview way Son Mateo, CA 94402 T..(&%) 638-1028 F:(650) 638-1029 (668)—SOL—aTY (765-2489) win.solarcity.com .119'-4 9'-5",F' 5T-3" 73'-7" (t)aarvwnr 49'-5" t 1\\ 13998 ��� r 131'-6' PROPERTY PLAN N Scale:l" = 40'-0' W E 0 40' 80' CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER J B- 9 5 9 7 215 O O NOISE OWNER: ' DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE BAHRAM KIASSAT BAHRAM KIASSAT RESIDENCE Austin Sch6e6baum �� ?� • BENEFIT OF ANYONE EXCEPT SOLARCIiY INC., MOUNTING SYSTEM: �►��SolarCity. NOR SHALL IT BE DISCLOSED IN.WHOLE OR IN zs Co 4 in rt 13998 LINDBERGH CIR 21.45 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S CHICO CA 95973 ORGANIZATION, EXCEPT IN CONNECTION WITH , 3055 aeaMeM Way THE SALE AND USE OF THE RESPECTIVE (66) SolarCity Standard #SC325 PAGE NAME SHEET REV. DATE: San Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650) 638-1028 F.(650) 638-1029 PERMISSION. of soLARaTY INC. SOLAREDGE sE10000A—us-Z8-u PROPERTY PLAN PV. 2 b 7/2/2017 (M) -SOL -CITY (765-2489) ..�,.Sao«Ity.�a�n PITCH: 40 ARRAY PITCH: 40 t MP1 AZIMUTH: 269 ARRAY AZIMUTH: 269 MATERIAL: Comp Shingle STORY:, 1 Story PITCH: 40 ARRAY PITCH: 40 MP4 AZIMUTH: 179 ARRAY AZIMUTH: 179 MATERIAL: Comp Shingle . STORY: 1 -Story PITCH: 40 ARRAY PITCH: 40 MP5 AZIMUTH: 179 ARRAY AZIMUTH: 179 MATERIAL: Comp Shingle STORY: 1 Story PITCH: 40 ARRAY PITCH: 40 IT `� MP10. AZIMUTH: 89 ARRAY AZIMUTH: 89 19) MATERIAL: Comp Shingle STORY: 1 Story PITCH: 40 ARRAY PITCH: 40 MP12 AZIMUTH: 89 ARRAY AZIMUTH: 89 M MATERIAL: Comp Shingle STORY: 1 Story PITCH: 40 ARRAY PITCH: 40 MP13 AZIMUTH: 89 ARRAY AZIMUTH: 89 A o MATERIAL: Comp Shingle. STORY: 1 Story 36 o LEGEND m to ® a L 0 (E) UTILITY METER & WARNING LABEL _ 3' FSB _ m mlInv INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS FDC W e DC�DISCONNECT & WARNING LABELS ' W © AC DISCONNECT & WARNING LABELS IT � T 0 DC JUNCTION/COMBINER. BOX & LABELS DISTRIBUTION PANEL & LABELS aA 4 MPS 3' FSB Q Lc LOAD CENTER & WARNING :.LABELS . ® Inv Q M DEDICATED PV SYSTEM METER - Inv RAPID SHUTDOWN — 3'FSIT- - Q STANDOFF LOCATIONS x CONDUIT RUN ON EXTERIOR =-- CONDUIT RUN ON INTERIOR, — GATE/FENCE Q Q HEAT PRODUCING VENTS ARE RED INTERIOR EQUIPMENT IS DASHED - L =�J SITE PLAN N Scale:1/16" = 1' w E 01' 16' 32'W MIA , S PREMISE OWNER' DESCRIPTION: - DESIGN: CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: JB -959721 5 00 Nm - CONTAINED. SHALL NOT BE USED FOR THE BAHRAM KIASSAT BAHRAM KIASSAT RESIDENCE Austin Schoenbaum g_. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �;;SOlarCity NWSHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing -Insert 13998 LINDBERGH CIR 21.45 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S MoOulEs CHICO CA 95973 ORGANIZATION, EXCEPT IN CONNECTION WITH ., 3055 Clearvier Way THE SALE AND USE OF THE RESPECTIVE (66) SolarCity Standard #SC325 PA( NAME SHEET: REY. DALE San Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T. (650) 638-1028 F:(650) 638-1029 PERMISSION OF SOLARCITY INC.SOLAREDGE SE10000A=US-ZB–U SITE PLAN PV 3 b 7/2/2017 (BBB) -SOL -CITY (765-2489) mw.sdaaiiyeom �1 . SIDE VIEW OF MPI NTS l H - PV MODULE X-SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES E dot 72", 24" 41" 0" NOTES 1 48" 21" 62" 0" RAFTER 2X6 @ 24" OC ROOF AZI 269 PITCH 40 STORIES: 1 0" ARRAY AZI 269 PITCH 40 C.7. 2x6 @24" OC Comp Shin le X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. PV MODULE X -SPACING X -CANTILEVER Y -SPACING 5/16"x1.5" BOLT WITH NOTES LANDSCAPE 5/16" FLAT WASHER 41" 0" 2X6 @ 24" OC 2x6 @24" OC PORTRAIT 48" 21" 62" INSTALLATION ORDER ZEP LEVELING FOOT 2x6 @ 24" OC 2x6 @24" OC ROOF AZI ARRAY AZI 179 PITCH 40 STORIES: 1 179 PITCH 40 Comp Shingle X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. LOCATE RAFTER, MARK HOLE ZEP ARRAY SKIRT {1) LOCATION, AND DRILL PILOT HOLE. ZEP MOUNTING BLOCK -- - - - - -) (4 --- -------- ATTACH FLASHING INSERT TO MOUNTING BLOCK AND ATTACH ZEP FLASHING INSERT(2) (3) TO RAFTER USING LAG SCREW. (E) COMP. SHINGLE (1) INJECT SEALANT INTO FLASHING (E) ROOF DECKING (2) (3) INSERT PORT, WHICH SPREADS SEALANT EVENLY OVER THE . 5/16" DIA STAINLESS ROOF PENETRATION. STEEL STEEL LAG SCREW LOWEST MODULE SUBSEQUENT MODULES "EMBED, MIN)INSTALL LEVELING FOOT ON TOP [(4) OF MOUNTING BLOCK & (E) RAFTER SECURELY FASTEN WITH BOLT. S 1 .STANDOFF ' CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER JB -9597215 0 0 PREMISE OWNER BAHRAM KIASSAT BENEFIT OF ANYONE EXCEPT SOLARCITY INC., SHAULISCLOUTSIE� IN BE DISCLOSEDOR IN MOUNTING SYSTEM: ZS Comp V4 w Flashing—Insert 13998 LINDBERGH CIR OTIT HERS E REGI IPE .PAORGANIZATION, EXCEPT IN CONNECTION WITH MODULES CHICO, CA 95973 THE SALE AND USE OF THE RESPECTIVE (66) SOlarCity Standard #SC325 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER PERMISSION of SOLARCITY INC. SOLAREDGE SE10000A-US-ZB-U ALJ SIDE VIEW OF MP5 NTS MP5 X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 72" 24" 41" 0" 2X6 @ 24" OC 2x6 @24" OC PORTRAIT 48" 21" 62" 0" RAFTER C.I. 2x6 @ 24" OC 2x6 @24" OC ROOF AZI ARRAY AZI 179 PITCH 40 STORIES: 1 179 PITCH 40 Comp Shingle X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. C BAHRAM KIASSAT RESIDENCE 21.45 KW PV ARRAY PAGE NAME STRUCTURAL VIEWS �D SIDE VIEW OF MP4 NTS MP4 X -SPACING X -CANTILEVER Y -SPACING I Y -CANTILEVER NOTES LANDSCAPE 72" 24" 41" 62" 0" 0" PORTRAIT 48" 21" RAFTER C.I. 2X6 @ 24" OC 2x6 @24" OC ROOF AZI ARRAY AZI 179 PITCH 40 STORIES: 1 179, PITCH 40 Comp Shingle X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. Austin Schoenbaum "So larCity 3055 Clearview Way SHEET: REV. DATE: San Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 PV 4 b 7/2/2017 (868) -SOL -CITY (765-2489) www.sdarcity.corn SIDE VIEW OF MP12 NTS MP12 X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 72" 24" Al"' 62" 0" 0" PORTRAIT 48"- 21". RAFTER G.J. 2X6 @ 24" OC 2x6 @24" OC ROOF AZI. ARRAY AZI 89 PITCH 40 STORIES: 1 - 89 PITCH 40 . Comp Shingle X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X' IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. r PREMISE OWNER: ' BAHRAM KIASSAT 13998 LINDBERGH CIR CHICO, CA 95973 M SIDE VIEW OF MPI 3 NTS MP13 X -SPACING X -CANTILEVER Y -SPACING CONFIDENTIAL - THE INFORMATION HEREIN. JW NUMBER: � JB -9597215 00 CONTAINED SHALL NOT BE USED FOR THE 41" 62" BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: + NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w flashing—Insert PART TO OTHERS OUTSIDE THE RECIPIENTS 89 PITCH 40 STORIES: 1 89 PITCH 40 Com Shingle ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE MODULES (66) SolarCity Standard #SC325 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN QF SOLARCITYINC. rRlPERMIssION REDGE SE10000A—US-ZB—U r PREMISE OWNER: ' BAHRAM KIASSAT 13998 LINDBERGH CIR CHICO, CA 95973 M SIDE VIEW OF MPI 3 NTS MP13 X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 72" 24" 41" 62" 0" 0" PORTRAIT 48" 21" RAFTER C.J. 2x6 @ 24" OC 2x6 @24" OC ROOF. AZI ARRAY AZI 89 PITCH 40 STORIES: 1 89 PITCH 40 Com Shingle rX ANDY ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. i DESCRIPTION: BAHRAM ,KIASSAT RESIDENCE 21.45 KW PV ARRAY PAGE NAME-- STRUCTURAL. AME STRUCTURAL .VIEWS Y(E) .LBW (�'SIDE VIEW OF MP10 NTS MP10 X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 72" 24" 41" 62" 0" 0" PORTRAIT 48" 21" RAFTER C.J. 2x6 @ 24" OC 2x6 @24" OC ROOF AZI ARRAY AZI 89 PITCH 40 STORIES: 1 89 PITCH . 40 Com Shingle X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. vravnc - - Austin Schoenbaum SolarLity. 3055 Geaniew Way SHEEP RE1k DATE San Mateo, CA 94402 T:(650) 638-1028 R(650),638-1029 PV • 5 b 7/2/2017 (888) -SOL -CITY (765-2489) www.soia.dty.com 4' • � N- .� • .. r rr • ' ' . r• . .... .. • � •. C � •-- T• ars i. + , CONFIDENTIAL — THE INFORMATION HEREIN -CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER ' J B=9597215 O O D:ESIG N SUMMARY DESIGN: Austin Schoenbaum \\\af �. 70 gn"CriierMa,' '^ + 139/•9+& LINDBERGH CIR ; 21.45' K_ W PV' ARRAY � , lkm i "Code ASCE 7=10 CHILO,. CA 95973 ` +ImportanEe Factor - . - .1' _ : _ _ .. _ X1:0 a .•.` ORGANIZATION, EXCEPT IN CONNECTION WITH THE SAIF AND USE OF THE RESPECTIVE . (66)-SoiarCity Standard' #SC325 . Ultimate Wind Speed V `Ult il'O mph 446.1609A PAGE NAYS �. UPLIFT CALCULATIONS p sExposure Category' E • T: (650) 638-1028 F: (650) 63B-1029 (888)—SOL—CITY (ass -246s> ..,salar�ltY.a«n ' " _ - 7VOTSeition 26 7 ":Ground' Snow Load p g ASCE Tabie'7,=1 ,..- MP M : MP�Name? -�- '�. �NiP.li - �-MP10.1 "MP32. �' MPt3' o ; r Roofi Comp Roof 4 Comp Roofs , ' Comp Roof¢ .: '. Com .:Roof z . -"Comp Roof t aCom Roof > .`_e � - Standoff: Coiop:MounfSRV CompMountSRV . ;Com" ,Nlount.SRV ;'Comp MouiitSRV ..Com Mount$RV - Comp MoiirnisRV s Pitch.• .' . ,r i Fa riay. :r: • Z 40'r ai4D;Jsr°" t:• W" SL/RLL PV'. 14.0 psf 14 0 psf: 14 0 `sf 14 0' a S0FtLl_- N6 PVA r *� ... , ' • w -.q Standioff,S cid sand. Aout " 4 MR.Name.': ' ;, �. MP1 - .MP.10•' - MP.12 �mkP MP4'" ,MPS: .. aX'S clni; n fit" * X Cantilever 24 24t 241' 24 24 24 4L ., Y -Cantilever: NA NA -_ .INA NA. NA NA' �, Xx ciny,'." t • �i48�"^ -' 48 .:_ t.4S":r .c_ "'t 4448"'.. 48-"` r ,� 48 o X'CantRCver: ; u kyss d . f, y I 62:.• * 21": �'r' 21 c 21 , .;62" • 'YY Untilevera ;, NA ,NA-, 1NA ",- ' NA•. - NA NA ' . %=Sta ered? i Not NoY Sia Bred Not Sta ered'3, ;Not-Sta Bred rNot Sta ered� Not St ereil�7 _ *.�. ,, X;and,Y;aremazlmums;thkare PV.,Xis'acrossrafters.aridYis`a16hg•:rifteis: CONFIDENTIAL — THE INFORMATION HEREIN -CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER ' J B=9597215 O O PREMISE OWNER: DESCRIPTION: BAHRAM KIASSAT - BAHRAM KIASSAT- RESIDENCE DESIGN: Austin Schoenbaum \\\af �. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALLBE DISCLOUTSIDSSED I IN MOUNTING SYSTEM:►;,SOIa�CIty ZS Comp`V4 wFlashing—Insert 139/•9+& LINDBERGH CIR ; 21.45' K_ W PV' ARRAY � , TO RECIPIENTSLEOR CHILO,. CA 95973 MODULES: ORGANIZATION, EXCEPT IN CONNECTION WITH THE SAIF AND USE OF THE RESPECTIVE . (66)-SoiarCity Standard' #SC325 . A way 3095 MateCleao, r San Moteo, CA 94402 SHEET: REM DATE SOLARgTY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SMENT. TY INC. PAGE NAYS �. UPLIFT CALCULATIONS - PV 6 .b 7/2/20.17 T: (650) 638-1028 F: (650) 63B-1029 (888)—SOL—CITY (ass -246s> ..,salar�ltY.a«n 01VER1ER SOLAREDGE SE10000A—US—ZB=U '. . r 4 i WARNING: PHOTOVOLTAIC POWER SOURCE Label •cation: 'Label, Location: (C)(IC)(CB) '•- WARNING ' = WARNING Code:Per CodeCode:CEC • 1 ELECTRIC SHOCK HAZARD ' • • 1 THIS EQUIPMENT FED BY 1 DO NOT TOUCH TERMINALS • .MULTIPLE SOURCES. TOTAL • -Location: TERMINALS ON BOTH LINE AND' RATING OF ALL OVER CURRENT LOAD SIDES MAY BE'EN'ERGIZED DEVICES, EXCLUDING MAIN PHOTOVOLTAIC DC IN THE OPEN POSITION DISCONNECTPer Code: SHALL OT EXCEEDAMPACITY CEC •' 1 OF B_USBAR. . a :"Label Location: Lab6l Location':PHOTOVOLTAIC POINT OF - • MAXIMUM POWERINTERCONNECTION _ ••- y A ' WARNING: ELECTRIC SHOCK CEC • 1 690.1 WARNING ' .d- • • POINT CURRENT (Imp) Perode HAZARD. DO NOT TOUCH AAAXIMUM POWER -®V Gait TERMINALS TERMINALS ON Per • • - POINT VOLTAGE (Vmp) ELECTRIC SHOCK HAZARD BOTH THE LINE AND LOAD SIDE • . 1 MAXIMUM SYSTEM V MAY BE ENERGIZED IN THE OPEN _ THE DC CONDUCTORS OF THIS VOLTAGE (Voc)® POSITION. FOR SERVICE PHOTOVOLTAIC SYSTEM ARETO BE SHORT-CIRCUIT A DE ENERGIZE BOTH SOURCE UNGROUNDED ANDINVERTERIS CURRENT (Isc)® MAY BE ENERGIZED AND MAIN BREAKER.UNGROUNDED PV POWER SOURCE MAXIMUM AC OPERATING CURRENT ®,n...... MAXIMUM AC LabelOPERATING VOLTAGE ® V .WARNING ELECTRIC SHOCK HAZARD 690.5(C). - Label, • 1 IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED . • -Location:' CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPIDPer Code SHUTDOWNCEC 690.56(C) Label Location: PHOTOVOLTAIC Ay' (AC) (POI) DISCONNECT :Per Code:., " ' Label Location: CEC 690.13.8• (POI) DUAL POWER • Per Code: - . ` •SECOND SOURCE ISrr , .. .. r •w • . • CEC 705.1`2.D.3 ., - ' Label "Location: MAXIMUM AC A (AC) (POI)'. ' OPERATING CURRENT Per -Code: -MAXIMUMAC ,+ ' OPERATING VOLTAGE CEC 690.54 Label Location: - .-� � (POI) �• 1 Per Code:INVERTER f OUTPUT CONNECTIO.CEC 705.12.D.2.b' . tr.. ' Label Location: ' NOT RELOCATE (AC): AC Discon F ''k -(C): Conduit nect (AC) .. �. � � • ,' � - - • :. . , PV SYSTEM.(CB): Combiner Box DISCONNECT • - �- r (D): Distribution PanelUTILITY :.(DC): DC Disconnect (IC)` Interior Run Conduit F _ (INV): Inverter With Integrated DC Disconnect (LC): Load Center .. (M): Utility Meter (POI):'Point of Interconnection' _ CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR 3055 Qearview Wa THE BENEFIT OF ANYONE EXCEPT• SOLARCITY INC., NOR SHALL IT BE DISCLOSED.T:(65) 638-1028 -.moi �•�r,�� San Mateo, CA 94402 s 0) 638-109 IEXIENTS CEPTIN NEC ONN YMOLE OR IN PART, TWITH THE SALE AND USE OOUTSIDE THE GPTHE RESPECTIVE (888) -SOL iIOM'� - Label Set r •�, OQTY(7652489)6wwwsolara?m ty.co SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION.OF SOLARCITY INC. : ,• '. • ' iaI o ' �.' x r- t • Label Location: PHOTOVOLTAIC Ay' (AC) (POI) DISCONNECT :Per Code:., " ' Label Location: CEC 690.13.8• (POI) DUAL POWER • Per Code: - . ` •SECOND SOURCE ISrr , .. .. r •w • . • CEC 705.1`2.D.3 ., - ' Label "Location: MAXIMUM AC A (AC) (POI)'. ' OPERATING CURRENT Per -Code: -MAXIMUMAC ,+ ' OPERATING VOLTAGE CEC 690.54 Label Location: - .-� � (POI) �• 1 Per Code:INVERTER f OUTPUT CONNECTIO.CEC 705.12.D.2.b' . tr.. ' Label Location: ' NOT RELOCATE (AC): AC Discon F ''k -(C): Conduit nect (AC) .. �. � � • ,' � - - • :. . , PV SYSTEM.(CB): Combiner Box DISCONNECT • - �- r (D): Distribution PanelUTILITY :.(DC): DC Disconnect (IC)` Interior Run Conduit F _ (INV): Inverter With Integrated DC Disconnect (LC): Load Center .. (M): Utility Meter (POI):'Point of Interconnection' _ CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR 3055 Qearview Wa THE BENEFIT OF ANYONE EXCEPT• SOLARCITY INC., NOR SHALL IT BE DISCLOSED.T:(65) 638-1028 -.moi �•�r,�� San Mateo, CA 94402 s 0) 638-109 IEXIENTS CEPTIN NEC ONN YMOLE OR IN PART, TWITH THE SALE AND USE OOUTSIDE THE GPTHE RESPECTIVE (888) -SOL iIOM'� - Label Set r •�, OQTY(7652489)6wwwsolara?m ty.co SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION.OF SOLARCITY INC. : ,• '. • ' iaI o ' �.' x �M '4SolarCity I ®pSolar DWV Debris Guard for composition shingle roofs PHOTOVOLTAIC MODULE DWV DEBRIS GUARD COMP ROOF MOUNT • COMP ROOF DWV Debris Guard Construction Detail ' QOOMPgr'B ~�pCOMPPTOv r ti a Next -Level PV Mounting Technology Debris Guard, close up Prevent blockages and keep, vents open with the DWV Debris Guard. Protects against: • Leaves Rain • Pine needles Insects • Snow Birds DWV Debris Guard is made of rugged 26 gauge galvanized steel. • , ,f. Listed by IAPMO to IGC -323 This document does not create any express warranty by Zap Solar or about its products or services. Zap Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zap Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely ` responsible for verifying the suitability of ZepSolar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. Document11800-1677-061 Rev C Date last exported: June 30, 2016 9:41 AM r t .L solar- • • SolarEdge Single Phase Inverters r For North America H3000A-US / SE380OA-US / SE5000A-US / SE6000A-US / SE760OA-US / SE1000OA-US / SE1140OA-US .Lrn'c .,r�.2.y ♦.., `J. c �,... .. F. ` } ,. lffa, - I- 'S G 8tta1►� i " �_ •a r-� � v� ' 4- 0 ti ,r - t 'r The best choice for SolarEdge enabled systems y , ,Specifically designed to work with power -optimizers s Integrated arc fault protection for NEC 2011690.11 compliance Rapid shutdown for NEC 2014 690.12 : + sem- �r • ' s • .i, - e . k i .. �{ ... ,� .. -.s Superior efficiency (98%) ".. r r: r Small, lightweight and easy to install on provided bracket' Built-in module -level monitoring: Internet connection through Ethernet or Wireless 4 Outdoor and indoor installation Fixed voltage inverter, DC/AC conversion only rr.: Pre -assembled Safety Switch for faster installation s- *� � -� Optional = revenue grade data, ANSI C12.1 USA - CANADA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - AUSTRALIA - THE NETHERLANDS - UK - ISRAEL - TURKEY - SOUTHAFRICA- BULGARIA www.solaredge.us 1 rSingle Phase Inverters for North America a r • • s o.l SE3000A-US / SE380OA-US / SE5000A-US / SE6000A-US / SE760OA-US / SE10000A-US / SE11400A-US ! SE3000A-US SE380OA-US I.SES000A-US sE6000A-US SE760OA-US I SE1000OA-US SE1140OA-US I1 )OUTPUT F Nominal AC Power Output 9980 @ 208V 3000 3800 5000 6000 760011400 VA _......................................... ...... ....... I ......... . 10000 240V Max. AC Power Output 3300 4150 5400 @ 208V 6000 8350 10800 @ 208V 12000 VA ............................................................................ 5450 240y.................................. 10.5Q.@A 240y ............................. AC Output Voltage Min: Nom: Max!ll p 183 - 208 - 229 Vac ............................................................................... AC Output Voltage Min. -Nom: Max.0l 211- 240 - 264 Vac :.. ........................................ A n in:N m:M x. 11 ............................ ................. ................................. .................. 59.3-60-60.5 Hz . Max Continuous Output Current........... (........ 1...?S.�° ).......32......1...42 12.5...... - .... .240y ..I...... 25....... -�pl- 240V...I...:.. 47.5........... A..... GFDI Threshold ......................... 1 ................................................................:...........................................'........................ A Utility Monitoring, Islanding Protection Country Configurable Thresholds Yes Yes INPUT .,, Maxlmum UC Power (STC) .. 4050 I 5100 6750 8100 10250 13500 15350 .... ......... .... .. .. .. ......... ... .......... ......... .... .... W ......... Transformer less Ungrounded Yes ... . Max. Input Voltage ........................................................................................................................ 500 Vdc ................. .............................................................................................................................I....................I..... Nom. DC Input Voltage 325 @ 208V / 350 @ 240V Vdc Max Input Currentl'I 16.5 @ 208V 33 @ 208V 9.5 I 13 . I 18 23 34.5 Adc ......... ...................... ............... ..... ............................. . ........ ..... Al 240y...................................3Q :?'.@ 240y.. Max. Input Short Circuit Current 45 ........................................................... . Adc Reverse -Polarity Protection ........................................................... .. .. . ' Yes ............................................. .................. Ground -Fault Isolation Detection 600ko Sensitivit ............. .. ... .........UM In ........................... i m Inv r ffi i n Max mu erte E c e ry .........................'...........................................................................:... 9 7.7 98.2 98.3 98.3 98 98 98 % ......................................................................................................................................................................... CEC Weighted Efficiency 97 @ 208V 97 @ 208V 97.5 98 97.5 97.5 97.5 . % ....................... ......::.... 98 @. 240y.. 97 ;5 �A 240y.. Ni httimePowerConsum tion g F <2.5 <4 W I ADDITIONAL FEATURES _ a Supported Communication Interfaces ........................................... RS485, RS232, Ethernet, ZigBee (optional) ..................... ....................nl............................. ........... ............... .... ....... Revenue Grade Data, ANSI C12.1 ........................................... Optional ........................... ..................... ...... ......................... ......... Rapid Shutdown - NEC 2014 690.12 _Yes _ �STANDARDCOMPLIANCE Safety .................................................................................... UL1741, UL17415A, UL1699B UL1998 CSA 22 2 .... ..... ..... Grid Connection Standards IEEE1547 Emissions FCC part1S class B = INSTALLATION SPECIFICATIONS - AC output conduit size / AWG range ............ 3/4" minimum/ 16-6 AWG 3/4" minimum / 8-3 AWG ....................................................I......... .......-. ......... DC input conduit size / p of strings /3/4" minimum / 1-3 strings / 3/4 minimum/ 1-2 strings/ 16-6 AWG AWG . .... ....... ......... ......... .. Dimensionsh Safe......i Dimensions with Safety Switch 30.5 x 12.5 x 10.5 / �" 30.5x12.5x7.2/775x315x184 in in / (FI%WXU)................................ ............................. . mg.... m .. WeihtwithSafetySwitch ;....................................... .,.,..,'51.2/23.2 88.4 / 40.1 ..........Ib/kg I g Natural convection Cooling Natural Convection and internal Fans (user replaceable) fan (user ......................................................................... replaceable). . Noise < 25 <.50 dBA ..-*................................................................................-...................................................................................... Min: Max. Operating Temperature -13 to +140 / 25 to +60 (40 to +60 version availablelal) -F /'C Rang?...................... :.. ....... .............. ............................................... ................................... .... Protection Rating NEMA 3R ........................................................................ nl For other regional settings please contact SolarEdge support. IA A higher current source may be used; the Inverter ISI w01 limit its input current to the values stated. a _ Revenue grade inverter P/N: SE-A-USOWNNR2 (for I'I.40 version P/N: SE-A-1.15000NN1.14 (for 7600W IAverter:5E7600A-US002NNU4). 7600W inverter-SE7600A-U5002NNR2). ; , 47, Mounting BlockArray Skirt Interlock Part No. 850-1633' Part No. 850-1608 or 500-0113 Part No. 850-1388 or 850-1613 / Listed to UL 2703 Listed to UL 2703 Listed to UL 2703 , b. • l J Jt 4' ti• Flashing Insert Grip . Ground Zep V2 , • , ' , : Part No. 850.1628 Part No. 850-16116 or 850-1421 Part No. 850-1511 , + • + �.,' ,' Listed to UL 2703 Listed to UL'270.3 Listed to UL 467 and UL 2703 Description . • E,ti w r c „r," ` PV mounting solution for composition shingle roofs r rFO� r. Works with all Zep Compatible Modules . r Auto bonding UL -listed hardware creates structural and electrical bond• ~ ZS Comp has a UL 1703 Class "A" Fire. Rating when installed using modules from r'. any manufacturer.certified as "Type 1" or "Type 2 p Captured Washer tag End Cap r DC Wire Clip ` V Part No. 850-1631-001 Part No. Part No. 850-1509 ®L LISTED - SpeCif Cations _ , + ' 850-1631-002 (L) 850-1586 or 850-1460 Listed to.UL 1565 •850-1631-003 (R)850-1588 or 850-1467 r t Designed for pitched roofs 850-1631-004 4' Installs in portrait and landscape orientations ' ZS Camp supports module wind uplift and snow load pressures to 50 psf per UL 2703 •r. Wind tunnel report to ASCE 7-05 and 7-10 standards • ZS Comp grounding products are UL listed to UL 2703 and UL 467' ` ZS Comp bonding products are UL listed to UL 2703 - �. `z• , • ° ., Engineered for spans up to 72" and cantilevers up to 24" • r + Zep .wire management products listed to UL 1565 for wire positioning devices f a • �.F =;',Leveling Foot' F y y Part No. 850-1397 • ,, zepsola�.com zepsolaccom Listed to UL 2703 « • This document does •not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services. Zep. Solar's sole warranty is contained in the written product warranty for , each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely each product. The end-user'documentation shipped with Zap Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely • responsible for verifying the suitability of ZepSolar's products for each use. Specifications are subject to change notice. Patents and Apps: zspats.com. - responsible for verifying the suitability of ZepSolar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com , - • �d • , Document # 800-1839-001 Rev D �� ';Date last exported: April 29, 2016 11:22 AM Document # 800-1839-001 Rev D • - Date last exported: April 29, 2016 11:22 AM: t , solar.-.. s, Solaffdge?6W.er Opthniid-r - Zep CompatibleTM Moddle Add -On For, North America P300-ZEP, P400-ZEP • z Compatible With Zep_ Girclovel ramed modulles' Ce rtifi6cl Zep 60 mpitible T- bracket' , Mitigates all types of module mismatch losses; from 4* t Attaches- to module fr' rrl� v�fithcI6 krews'- reLces on -roof ,manufacturing tolerance to partial shading 1i "labor, and mounting costs 4 1 0 Flexible system design for maximum space utilization P 0, wer optimizer equipment grounded through the bracket, Next generation maintenance with module -level monitoring UP Waclul'-IeV�l shutdown to 25%'more erieigy, le voltage shUdo for installer and firefighter :11. ,�up -­ —i P - - 11 1 1 . . 4 safety saf t 7 erioreffiiiency.(99.5%),­ -4 USA -CANADA -GERMANY -ITALY -FRANCE -JAPAN -CHINA -AUSTRALIA -THE NETHERLANDS -UK - ISRAEL - TURKEY -HUNGARY -BELGIUM -ROMANIA -BULGARIA www.solaredge.us $ojcj� =gg SolarEdge Power Optimizer - Zep -CompatibleTM Module Add -On' For North America P400-ZEP P400-ZEP (for 60 -cell PV modules) I P400-ZEP(fbr72i9&cellmodules) F-, JINPUT , ..Rated Input DC poweril) ........ * .................... * .......... ................ �0. 0 .... A .. .............. ........ I 4.00.. .................. ..... W.......... Absolute Maximum Input Voltage (Voc at lowest. ................ A 48 80Vdc ..�e�perature) ...................... I ........... ........................................ ...... ............................... : ......... I ...... .............. M..P.PT!Ojpe�ng Range 8-80 Vdc Short Circuit Current . ............. .�rc.Curnt................... 1 10 .Maximum . ... ...................................... . ................... ........................ Adc. b.... Maximum DC Input Current ...........I........... ........................ 12.5 1 ..................I.;.................................... .................................. Adc Maxim6m Efficiency99.5 ...................................................... .......... ............ : ......................... q ........................................................ % . .............. . .,Weighted Efficiency........ ............. ........... 9.8..8. ................................. % ..................... Cate,go'ry .............. —Ove'r*vo"lta'ge' _IOUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) Maxi.mu.r.n.Output ,Current .... ..... ................. .............. ............... .............C ...... Maximum Output Voltage 60 Vdc FOUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF),' Safety Output Voltage per Power Optimizer 1. Vdc ISTANDARD COMPLIANCE EMC. .............. ....... FCCParlSClassB,IEC61000-6.-2,IEC6000-6-3 . ....... ...........,..,.......... ..................... ........ Safety. . ......... ..............I.......................... .................................... IEC62109-I(class1lsafety), UL1741 .............. . ROHS - :1 Yes INSTALLATION SPECIFICATIONS ..r�axiTu.m.Allowed .S,ystem .Volta .ge ....... ............... .................... 000 '...... ................................................ ..... Vd.c ..... Dimensions including mounting bracket (WxLxH) : 128 x 196 x 27.5 / 5 x 7.71 x 1.08 128 x'196 x 35 / 5 x 7.71 x 1.37 mm/in .......... ....................................... .............. Dimensions excluding mounting bracket (WxLxH) ................. ............................. .......... I .................................... ............ 128 x 152 x 35 / 128 x 152 x 27.5 / 5 x 5.97 x 1.08 . mm in 5 x 5.97 x 1.37 , ..... .............. ............ I .................................................... ..Weight (including cables and mounting bracket) ..... * ........... * ....... * ........... * ..... * ...... ...... I ............ ........................... ......................................... : ...... ........ 7.20. /..1:15 .... ............ . .................. 8.40./..l...9 .......... ....... ... kg/.Ib .... Input Connector ..... ............. .................. MC4Compatible, ...... ................. ........... ....................... .............. Output Connector ....... I ........... ................ ........ ........... Double Insulated; MC4 Compatible . .......... ........ I ............. ..Output Wire Length ............................................................ 0.95/3.0 1.2'/'3'.*9 ..................................... I ......... ............................................... .............. ..9pFrating Temperature Range ..... .... ......... * ........ ........................ -40=+85/.40;+185 'C/'F ......... -1 ................. ........ ..... ..... * .......... * ................ * ..... .... ProtectionRatin'g* I ................................................................. I,P6'8'/'N`EMA6'P ............................................ .................................................. .............. Relative Humidity ........... * ...... * ................ 0-100 % ......... ............... ................................................. : ............... ........... Rated STC power of the module. Module of up to +5% power tolerance allowed. PV SYSTEM DESIGNUSINGA SINGLE PHASE THIREE PHASE THREEPIHASE- iPH SING E ASE SOLAREDdE INVERTER (2). HD WAVE L 208V 480V ..Minimum String Length (Power Optimizers)......... ............ * ...... **"* ....... * .. ...... * ...... ..r * .............. .8 .................. ....... ..10 .......... 1.8 ........... ............. Maximum String Length (Poweptimizers) O 25 25 50 I. .................................... *.,., : 57 00 60 00 Wih 'Maximum Power per String ................................. ...... .... ........... 5250 6000 12750 .... SE760OH-........ ........ ........ W ............. Parallel Strings of Different Lengths or Orientations ..................................... : .................. Yes ................................................................... .................................... ............. • ")For detailed string sizing information refer to: hnpl/ww lamdge.mm/sites/default/files/string_sizingna.pdt 9 SC325SolarCityE L ECTR ICA CAND..M ECH AN I CAL 'CH A OACTER I ST I CS" . A ELECTRICAL DATA - MECHANICAL DATA Weight: 42.99lbs Dimensi;ns: 62.6"/41.5"/1.57" Connector 10114:4 Frame Color: Black Snow load: 5400 Pa Wind load: 2400 Pa Fire Type: Type 2 . ............ . ...... . . ............... . ....... . ...... . ... . . . ... . ... .................. . ... . . ....... . . .... . . ........................ ....... . ................... . . . ....................... Temp. coefficient of Pmax [%/*C] Temp. coefficient of,Voc (%/*C •.0.235 -0.258 Max. power (Pmax) [W L 325 Temp. coefficient of Isc [%/*C] I Ulu'. pUW(:�r, . . ........................................ ......... . .. . ... . .............. . ............................. •Max. power v Itage (Vmp(VI . ... . ................. . ... ........................................ . .. . ..... .... 57.6 V Max. power current (imp) (A] '5.65' AT.(NORMAL OPERATING CONDITIONS) Open circuit voltage (Voc) [V] 69.6 Ire Max. power (Pmax) [W] 247.5 Short circuit current (Isc) [A] 6.03 ss pan Max. Power voltage (Vmp) CV) 54.2 Max. over current rating (A) is I Max. power current (Imp) [A] 4.56 '� •W •Open Power tolerance600 +5/-0 66.1 10 tL_, •Short or& Max. system voltage EVI circuit current (Isc) [A] 4.87 'Solar Panel efficiency 19.4 r Note: Normal Operating Cell Temp, Ali mass 1.5; Irradiance 80OW/.2 2 4. "- Air temperature 20°C; wind speed I m/s Note: Standard Test Conditions: Air mass 1:5; Irradiance I000WJ.2; cell temp.25°C 'Maximum power at delivery. For limited warranty conditions, please check our limited warranty document. AT LOW IRRADIANCE (20%) 'TEMPERATURE CHARACTERISTICS" Temperature (NOCT) [*C] 44.0 Weight: 42.99lbs Dimensi;ns: 62.6"/41.5"/1.57" Connector 10114:4 Frame Color: Black Snow load: 5400 Pa Wind load: 2400 Pa Fire Type: Type 2 . ............ . ...... . . ............... . ....... . ...... . ... . . . ... . ... .................. . ... . . ....... . . .... . . ........................ ....... . ................... . . . ....................... • Section.A­-K Section B -B' More power per pane With a,sunlight to electricity*'62.0 Our 325W panel generates 20% more power than a standard Max. power (Pmax) [W] 4. Max. power voltage (Vmp) [V] 55.7 conversion l6ffidiency 6f over 19.4% 270W panel. DEPENDENCE ON IRRADIANCE Max. power current (Imp) [A] 1.11 Open circuit voltage (Voc) [V] 65.1 7jDO 4 'More yearly energy (kWh) compared to other panels as they perform ........................... . ............. ........................ . ........ . ................. . . . . . . . . ..... OOW/-' the panel,ranks amongst the More energy every year Short circuit current (Isc) (A] 1.21 _ - 1 , - . I 1 4 1 : ;0• highest in the industry. That means better in the heat. rt Note: La. irradiance: Air mass 1.5; Irradiance = 20OW/m2; cell temp. = 25*Cvv 600 W/ ............... ...... ..... SDD . ....... . .. ................. . . ..................... ........................ ............ ...... ............... . ..... ................ ...... our panels 'can harvest Outstanding durability With more than 20 additional tests performed beyond what is LIMITED, Power output: 10 years (46% of Pmin) J1 e-nergy,from the sun ,,which means currently mandated,'these panels far exceed industry standards. WA�RANTY �5 years (80� of Pmin) L I a Workm nship:, I years . it,takes fe'\Aier.of our panels to W/rw More layers, more power Manufactured by Panasonic for SolarCity, the panel uses power your home., Plus, they MATERIALS Cell material: 5 inch photovoltaic cells zoo Heterojunction cell technology, which adds a layer of thin film silicon AR coated I . emp'ereci glass wim Glass material: generate more ppwer output on top of high efficiency cyrstalline silicon. 1.00 ===Z== Frame materials: Black anodized aluminium Con . nectors typ�. MC4 ' '- : Sv during,tHe hottest times of the day, L .. . ......... . ... .... • Leadingwarranty 0,001 . ............. ............ Our panels rank among the best in warranty coverage, 0 20 30 "40 50 60 70 so 10 even in warmer dlimates � workmanship that extends to 15 years. L CAUTiONI Please read the installation manual carefully With before using . the products. A L Panels are manufactured by Panasonic to the specification of SolarCity. Panels are only warranted by Panasonic • E06 'Ro"_ I I I Q ' I SolarCi�y . .. :E ". -C 01.1111THI IZC6 if the panels are included in a PV system sold by SolarCity or Tesla. SolarCity and Tesla make no warranties C6173D.2 ❑ sol;rcity.com k solarcity.c m related to the panels, which are sold as -Is. SolarCity will handle any warranty claims on behalf If of any purchaser. .0 a 4 Temp. coefficient of Pmax [%/*C] Temp. coefficient of,Voc (%/*C •.0.235 -0.258 Temp. coefficient of Isc [%/*C] 0.055 • AT.(NORMAL OPERATING CONDITIONS) Max. power (Pmax) [W] 247.5 Max. Power voltage (Vmp) CV) 54.2 Max. power current (Imp) [A] 4.56 '� •W •Open circuit voltage (Voc) CV) 66.1 10 tL_, •Short or& circuit current (Isc) [A] 4.87 Note: Normal Operating Cell Temp, Ali mass 1.5; Irradiance 80OW/.2 2 4. "- Air temperature 20°C; wind speed I m/s AT LOW IRRADIANCE (20%) • Section.A­-K Section B -B' More power per pane With a,sunlight to electricity*'62.0 Our 325W panel generates 20% more power than a standard Max. power (Pmax) [W] 4. Max. power voltage (Vmp) [V] 55.7 conversion l6ffidiency 6f over 19.4% 270W panel. DEPENDENCE ON IRRADIANCE Max. power current (Imp) [A] 1.11 Open circuit voltage (Voc) [V] 65.1 7jDO 4 'More yearly energy (kWh) compared to other panels as they perform ........................... . ............. ........................ . ........ . ................. . . . . . . . . ..... OOW/-' the panel,ranks amongst the More energy every year Short circuit current (Isc) (A] 1.21 _ - 1 , - . I 1 4 1 : ;0• highest in the industry. That means better in the heat. rt Note: La. irradiance: Air mass 1.5; Irradiance = 20OW/m2; cell temp. = 25*Cvv 600 W/ ............... ...... ..... SDD . ....... . .. ................. . . ..................... ........................ ............ ...... ............... . ..... ................ ...... our panels 'can harvest Outstanding durability With more than 20 additional tests performed beyond what is LIMITED, Power output: 10 years (46% of Pmin) J1 e-nergy,from the sun ,,which means currently mandated,'these panels far exceed industry standards. WA�RANTY �5 years (80� of Pmin) L I a Workm nship:, I years . it,takes fe'\Aier.of our panels to W/rw More layers, more power Manufactured by Panasonic for SolarCity, the panel uses power your home., Plus, they MATERIALS Cell material: 5 inch photovoltaic cells zoo Heterojunction cell technology, which adds a layer of thin film silicon AR coated I . emp'ereci glass wim Glass material: generate more ppwer output on top of high efficiency cyrstalline silicon. 1.00 ===Z== Frame materials: Black anodized aluminium Con . nectors typ�. MC4 ' '- : Sv during,tHe hottest times of the day, L .. . ......... . ... .... • Leadingwarranty 0,001 . ............. ............ Our panels rank among the best in warranty coverage, 0 20 30 "40 50 60 70 so 10 even in warmer dlimates � workmanship that extends to 15 years. L CAUTiONI Please read the installation manual carefully With before using . the products. A L Panels are manufactured by Panasonic to the specification of SolarCity. Panels are only warranted by Panasonic • E06 'Ro"_ I I I Q ' I SolarCi�y . .. :E ". -C 01.1111THI IZC6 if the panels are included in a PV system sold by SolarCity or Tesla. SolarCity and Tesla make no warranties C6173D.2 ❑ sol;rcity.com k solarcity.c m related to the panels, which are sold as -Is. SolarCity will handle any warranty claims on behalf If of any purchaser. .0 a 4