Loading...
HomeMy WebLinkAboutB17-1215 042-160-019I I P GENERAL NOTES I 1) ALL HEADERS TO BE 412 6 2x4 WALLS 4 6x12 S) PROVIDE ON JOB SITE ADDRESS NUMBERS 18) MECHANICAL DUCT OPENINGS 4 OTHER 28) AFCI PROTECTION IS REQD, THROUGHOUT THE 31) WATER HEATER TO HAVE : 41) PLUMBING FIXTURES WILL COMPLY w/ CA, 46) PROVIDE A MIN. OF (1) 20AMP, RECEPTACLE D, F, 01 6 2x(o WALLS, - U, 0, N, PLAINLY VISIBLE 4 LEGIBLE FROM THE PUBLIC RELATED OPENINGS TO BE COVERED DWELLING AS PER 2016 CEC ART, 210,12 (A) . A) 2 - SEISMIC STRAPS, ONE STRAP IT UPPER SENATE BILL 401 , FOR THE INSTALLATION IN LAUNDRY AREA , AS PER CEC 210,52 F , 2) CONTRACTOR TO FOLLOW ALL OF 2016 CALGreen STREET , NUMBERS TO CONTRAST w/ THEIR DURING CONSTRUCTION PER CGBS 4.504,1. ALL 120V SINGLE PHASE, 15 4 20AMP, BRANCH 1/3 4 2nd STRAP TO BE s LOWER 1/3 NO OF WATER CONSERVING FIXTURES, 41) EXTERIOR WINDOWS TO BE DUAL PANE w/ ONE RESIDENTIAL MANDATORY MEASURES . BACKGROUND 4 TO BE A MIN, OF 4 HIGH w/ CIRCUITS SUPPLYING OUTLETS TO BE CLOSER THEN 4 OF CONTROLS, 42) LIGHT FIXTURES IN TUB or SHOWER ENCLOSURES PANE TO BE TEMPERED AS PER 2016 CRC A MIN. STROKE WIDTH OF 1/2" , 19) ADHESIVES ,SEALANTS ,CAULKS ,PAINT PROTECTED BY A LISTED ARC -FAULT �� �� SECTION R321,8 . CHAPTER 4 . STAINS , AEROSOL PAINTS , CARPET 4 );A CATEGORY 3 or 4 VENT, or a B VENT TO BE LABELED, SUITABLE FOR DAMP INTERRUPTER COMBINATION TYPE INSTALLED 48) EXTERIOR DOORS TO COMPLY w/ 2016 CRC 3) FIXTURES, LAMPS HOLDERS 4 OUTLETS TO BE 10) ALL EXTERIOR OPENINGS, INTERSECTIONS RESILIENT FLOORING TO COMPLY w/ VOC TO PROVIDE PROTECTION TO THE BRANCH w/ STRAIGHT PIPE BETWEEN THE OUTSIDE LOCATION". AS PER 2016 CEC ART, SECURELY SUPPORTED, A FIXTURE WEIGHING 4 ATTACHMENTS AS LISTED IN CRC R103,8 4 OTHER TOXIC COMPOUNDS LIMITS PER CIRCUIT INCLUDING LIGHTS RECEPTACLES TERMINATION 4 THE SPACE WHERE THE 410,10 (A) 4 (D), SECTION R321,8,1 , MORE THAN (6) POUNDS OR EXCEEDS 16" IN TO HAVE CORROSION - RESISTANT FLASHING, CGBS 4,504 , 4 SMOKE DETECTORS ,_ WATER HEATER IS INSTALLED. NTRY DOOR TO HAVE A MAXIMUM LANDING . ANY DIMENSION SHALL NOT BE SUPPORTED 20) MOISTURE CONTENT OF BLDG. MATERIALS C) CONDENSATE DRAIN THAT IS NO MORE 43) THE SERVICE or SUB -PANEL CIRCUIT DIRECTORY HEIGHT OF 13/4 BELOW THE TOP OF THE BY THE SCREW SHELL OF A LAMP HOLDER. 11) GFCI REQD, FOR ALL 12 -VOLT RECEPTACLES, USED IN WALLS 4 FLOOR FRAMING IS NOT 29) ALL 125V SINGLE PHASE, 15 4 20AMP, THAN 2" HIGHER THAN THE BASE OF THE SHALL IDENTIFY THE OVERCORRECT DEVICE THRESHOLD, OUTLET BOXES SHALL NOT BE USED AS THE TO BE ENCLOSED IF THE FRAMING MEMBERS RECEPTACLES SHALL BE LISTED AS TAMPER INSTALLED WATER HEATER, AND ALLOWS SPACES) AS RESERVED FOR FUTURE ELECTRIC SOLE SUPPORT FOR CEILING (PADDLE) FANS. 12) PROVIDE 26 GA, CORROSION RESISTANT EXCEED 19°r, MOISTURE CONTENT AS REQD. RESISTANT RECEPTICALES AS PER 2016 CEC NATURAL DRAINING w/OUT PUMP ASSISTANCE. VEHICLE CHARGING AS "EV CAPABLE, THE 5077AUTOMATIC GARAGE DOOR OPENER TO BE SCREED w/ 3 1/2 MIN, VERTICAL FLANGE BY CGBS 4,505, ART. 406.12 , RACEWAY TERMINATION LOCATION SHALL BE UL LISTED. D) A GAS SUPPLY LINE w/ A CAPACITY OF s 4) BATH ROOMS, TO BE SERVED BY A SEPARATE TO BE INSTALLED 1" BELOW THE FOUNDATION PERMANENTLY 4 VISIBLY MARKED AS 20 AMP, BRANCH CIRCUIT. THIS CIRCUIT TO 30) ALL LIGHTING IN GARAGE 4 LAUNDRY RM, LEAST 200,000 BTU / HR, �� �� �31)�FACtORY BUILT FIREPLACE t0 BE LISTED 4 PLATE LINE AS PER SECTION R103,6. THE 21) PROVIDE EXTERIER PLASTER SIDING OVER TO BE CONTROLLED BY VACANCY SENSORS. EV CAPABLE LABELED, 4 TO BE INSTALLED IN ACCORDANCE SERVE NO OCHER OUTLETS. WATER RESISTANT BARRIER SHALL LAP OVER WEATHER - RESISTIVE BARRIER AS PER CEnC SECT. 150,0(k)(o, 38) CARBON MONOXIDE ALARMS TO BE DIRECT 44) THE GROUND IMMEDIATELY ADLACENT TO THE w/ THE CONDITIONS OF THE LISTING, FACTORY THE EXTERIOR OF THE SCREED FLANGE. CRC 103 . B) BATH �2 EXHAUST FAN t0 DOUBLE AS THE WIRED TO BLDG, w/ BATTERY BACKUP 4 FOUNDATION SHALL BE SLOPED AWAY FROM BUILT FIREPLACE TO BE TESTED IN AS PER 2016 CRC SECTION R103,6 4 R103,1, 31) PROVIDE A MIN, OF (2) 20AMP, SMALL INTERCONNECTED TO ALL OTHER C M ALARMS THE BLDG, tv A SLOPE OF NOT LESS THAN 6" ACCORDANCE w/ UL 121, WHOLE -BLDG, EXHAUST FAN 4 TO BE 15 cfm 22) ALL LIGHTING TO BE 100io NIGH EFFICACY . APPLIANCE BRANCH CIRCUITS EVENLY ' w/ 6" DIA. SMOOTH DUCT - 145' MAX. LENGTH , 13) DRILLING 4 NOTCHING STUDS TO BE IN AS PER CRC R315 . WITHIN THE FIRST 10'0" lBio SLOPE). AS PER FAN TO BE RATED 6 1 - SONE , FAN SWITCH TO ACCORDANCE w/ CRC R602,T . 23) MAX, FLOW RATES FOR PLUMBING FIXTURES : PROPORTIONED IN THE KITCHEN, PANTRY, 2016 CRC SECTION R401.3 . . BATHTUB 4 SHOWER FLOOR 4 WALLS ABOVE BE LABELED , WHOLE BUILDING VENTILATION TOILETS = 1.28 GPM SHWR, HEADS -- 2.0 GPM DINING or SIMILAR AREAS TO SERVE ALL WALL 39) EACH ATTIC F. A, U, TO HAVE A 22"x 30" ATTIC BATHTUB w/ SHOWER HEADS 4 SHOWER ' 4 FLOOR RECEPTACLES, SUCH CIRCUITS SHALL COMPARTMENTS TO BE FINISHED w/ FAN SHOULD OPERATE WHENEVER THE HOME 14) DOUBLE TOP PLATES TO HAVE A MIN, LAP LAUNDRY FAUCETS = 2,2 GPM , 4 ACCESS w/ 24 WIDE SOLID WALKWAY TO THE {4 HE BUILDER SHALL INSTALL A NORMAL 1 INSIDE �� HAVE NO OTHER OUTLETS PER 2016 CEC � � NONABSORBENT SURFACE. SUCH WALL IS OCCUPIED . OF 24 , NAIL w/ 8 - 16d ON EA. SIDE OF JOINT SINK FAUCETS = 1,8 GPM . ART. 210,52(B) . F. A. �U, NOT TO EXCEED 20 LONG. PROVIDE DIAMETER, LISTED RACEWAY TO ACCOMIDATE A SURFACES TO EXTEND TO A HEIGHT OF NOT U, 0, N, , LAP PLATES IT INTERSECTIONS 4 A 30 SQ, SOLID PLATFORM IN FRONT OF THE DEDICATED 208/240 VOLT BRANCH CIRCUIT, LESS THAN 6 ABOVE THE FLOOR, (o) BATH RM, EXHAUST FANS TO BE "ENERGY CORNERS. 24) ALL TUBS 4 TUB/SHOWERS TO HAVE INDIVIDUAL 32) BOND ALL METAL GAS 4 WATER PIPES FURNACE SERVICE LOCATION 4 A LIGHT FIXTURE THE RACEWAY SHALL ORIGINATE IN THE MAIN STAR" COMPLIANT 4 TO BE DUCTED t0 BE CONTROL VALVES FOR PRESSURE BALANCE 4 TO GROUND .ALL GROUND CLAMPS TO 4 ELEC, OUTLET NEAR THE FURNACE AS PER OR SUB -PANEL, 4 WILL TERMINATE INTO A LISTED 3) PLUMBING FIXTURES 4 FITTINGS TO COMPLY 5" DIA, FLEX DUCT -10' MAX. LENGTH AND 15) PROVIDE FIRE BLOCKING AS PER CRC R302,11 . THERMOSTATIC BALANCE or COMBINATION BE AN APPROVED TYPE 4 ACCESSIBLE . CMC 306,4 . BOX s THE PURPOSED SITE OF AN ELECTRIC w/ CGBSC 4,303. TERMINATE OUTSIDE THE BUILDING 4 TO PRESSURE BALANCE/THERMOSTATIC MIXING 33) PROVIDE EROSION CONTROL 4 STORM VEHICLE CHARGER, THIS AND ALL ADDITIONAL54) GARAGE DOOR HEADERS TO HAVE DOUBLE BE CONTROLLED BY A HUMIDITY CONTROL 16) ANNULAR SPACES AROUND PIPES , CABLES, VALVE TYPE. CPC SECT, 408.3 WATER POLLUTION PREVENTION MEASURES 40) ATTIC MOUNTED F, A, U, TO HAVE NOT LESS SPECS, OF THE CA, GREEN BLDG, STANDARDS TOP PLATE. CAPABLE OF ADJUSTMENT BETWEEN A CONDUITS , or OTHER OPENINGS IN PLATES THEN 6" MIN, SIDE CLEARANCE 4 2" MIN, TOP 4 SECTION 4,106.4 SHALL BE MET. RELATIVE HUMIDITY RANGE OF 50% TO 80%, EXT, WALLS TO BE PROTECTED FROM RODENT 25) DRYER VENT DUCT TO BE A MIN, 4" DIA, TO DURING CONSTRUCTION . BOTTOM CLEARANCE. AS PER 2016 CGBS 4,50(o, PASSAGE BY CLOSING OPENINGS AS PER THE OUTSIDE 4 EQUIPPED w/ A BACK DRAFT 34) ALL HOSE BIBBS (EXCEPT CLOTHES WASHER 1) ALL EXHAUST FANS (INCLUDING RANGE HOOD) CGBS SECTION 4.40(o . DAMPER . CONNECTION) TO HAVE ANTI -SIPHON DEVICE . TO HAVE A BACK DRAFT DAMPER. 11) AT THE TIME OF FINAL INSPECTION , AN 26) PROVIDE SEPARATE GROUND WIRE TO ALL 3B) LAUNDRY RM, OUTLETS TO BE SERVED BY OPERATION 4 MAINTENANCE MANUAL, PANELS FROM MAIN SERVICE ENTRANCE LEAST (1) 20AMP, BRANCH CIRCUIT. THIS 7 CONCRETE 5FD 8) FIRE SPRINKLER PLANS ARE A DEFERRED ACCEPTABLE TO THE ENFORCING AGENCY , PANEL, AS PER 2016 CEC ART, 250-32, CIRCUIT TO SERVE NO OTHER OUTLETS, SUBMITTAL, TO BE SUMITTED PRIOR TO ROUGH TO BE PROVIDED TO THE OWNER PER 21) ALL EXTERIOR RECPTACLES MUST BE WATER 36) SMOKE ALARMS TO BE DIRECT WIRED TO BLDG, 1, ALL CONCRETE TO HAVE A MINIMUM OF 3,000 PSI AFTER 28 DAYS CURING, 1, RE -BAR TO CONFORM TO THE ASTM A -615/A -615M -04a, 4 RE -BAR 4 SMALLER FRAMING INSPECTION, 2,500 PSI IS USED FOR DESIGN SO NO SPECIAL INSPECTION IS REQUIRED. TO BE GRADE 40, #5 RE -BAR 4 LARGER TO BE GRADE 60, ALL RE -BAR TO CGBS 4,410 . PROOF/ GFCI PROTECTED, AS PER 2016 CEC w/ BATTERY BACKUP 4 INTERCONNECTED TO 2, MATERIALS USED TO PRODUCE CONCRETE, CONCRETE ITSELF 4 TESTING TO BE DEFORMED, DO NOT RE -BEND *5 RE -BAR 4 LARGER . ART. 210.32 (E) (1) 4 210,8. ALL OTHER ALARMS . AS PER CRC R314 . COMPLY w/ APPLICABLE STANDARDS LISTED IN ACI 318, AGGREGATE SIZE 2 Al A LAP SPLICES t0 BE A MINIMUM OF 62 RE -BAR DIAMETERS TO BE A MAXIMUM OF 11/2" IN FOOTINGS 4 3/4" IN SLABS, 3, CURING COMPOUND TO BE SPRAYED ON ALL EXPOSED SURFACES IMMEDIATELY AFTER FINAL TROWELING, 4, ALL CEMENT USED TO CONFORM TO ASTM C-150-04 4 TO BE TYPE II or III LOW ALKALI, 5, CONCRETE EXPOSED TO FREEZING 4 THAWING TO BE PROTECTED IN ACCORDANCE TO THE LATEST EDITION OF THE ACI 4 CBC SECT. 1504, 6, VIBRATE CONCRETE AROUND ALL BOLTS, RE -BAR 4 VERTICAL SURFACES, 1, COLD JOINTS BETWEEN FOOTINGS 4 SLABS TO BE CLEAN 4 WET PRIOR TO POURING CONCRETE. 8, CALCIUM CHLORIDE or CHLORIDE BASED MIXTURES ARE NOT TO BE USED, BUM COUNTY JUL 13 2017 DEVELOPMENT SERVICES X17-�d15 PROP. LINE 2393.00' O-----------------------------------------------------w----- E----------------------- ----------------------------------------W----- E--- ----------- ---_---------------------- �i i `� ; ; NEW SEPTIC NEW WATER LINE TANK ------------ -------------------------- ----100- EX, WELL 200 AMP: GRAVEL PARKING •-------------------------------------------------- 50,0 ----------------------------------------------- 'PANEL 50' 0" CENTER LINE _ OF ENTRY ri 0 NEW CONC. • HOUSE WALK EXIST. SHED-.[ 300, 0" 1 GAR, 100,011 �------ �rNEW L/P TANK CONC, o APR PROP, LINE ER05ION CONTROL NOTES 1) NO SOIL DISTURBANCE SHALL OCCUR PRIOR TO 8) PROVIDE A DESIGNATED AREA FOR CONCRETE OBTAINING A BUILDING or GRADING PERMIT, WASHOUT. ALL CONCRETE WASHOUT SYSTEMS TO 2) PHONE " of PERSON RESPONSIBLE for EROSION BE PLACED OFF OF THE STREET Vor SIDEWAK, CONTROL IS : DANIEL WEBB 530/ 8SI-0845 S) STRAW ROLLS TO BE INSTALLED PROPERLY 3) EROSION CONTROL MEASURES SHALL BE IN PLACE INSTALLED BEHIND CURB and/or SIDEWALK. BETWEEN OCT, 15th 4 APRIL 15th or WHEN RAIN IS 10) 2 - ROCK BAGS (MIN.) 9 EACH SIDE OF ALL DRAIN (P FORCASTED , INLETS LOCATED w/IN 150' OF PROJECT SITE. 4) STABILIZE ENRTY w/ MIN, 3" to 6" FRACTURED 11) ALL DRAIN INLETS AFFECTED SHALL HAVE INTERNAL ROCK 50' LONG x 15' WIDE x 6" DEEP OVER FILTERS PLACED INSIDE. 5Q. FT, CALC5. CONSTRUCTION GRADE FABRIC, 12) ALL DRAIN INLETS AFFECTED SHALL HAVE TRASH 5) SOILS TRACKED OFF SITE INTO STREET SHALL BE BARS PLACED ACROSS THE BACK. = 2884 SQ, FT. CLEANED UP 9 THE END of EACH WORK DAY. WHEN GARAGE = ISS SQ, FT, GREETS ARE WET or DURING A RAIN EVENT THERE 13) STABILIZE ALL DISTURBED SOILS IN THE FRONT = 3S9 SQ, FT, SHALL BE NO TRACKING OF SOIL INTO STREET, YARD AREAS w/IN 15' OF THE BACK OF ROAD WAY 6) INACTIVE SOIL STOCKPILES SHALL BE COVERED . w/ STRAW ROLLS or EROSION BLANKETS, ACTIVE STOCKPILES SHALL BE COVERED PRIOR 14) STABILIZE ALL SLOPES WHERE EROSION COULD -- 84 SQ, FTI TO A FORCASTED RAIN EVENT , OCCUR, USE STRAW ROLLS, VISQUEEN or EROSION 1) THE EROSION CONTROL PLAN SHALL BE BLANKETS. 0 MAINTAINED, RE-EVALUATED 4 ADJUSTED 15) INACTIVE SOIL STOCKPILES SHALL BE COVERED, ACCORDINGLY, AS THE SITE CHANGES 4 ACTIVE STOCKPILES SHALL BE COVERED PRIOR AFTER RIAN EVENTS . TO A FORCASTED RAIN EVENT, \-1,__ NEW GRAVEL DRIVEWAY NEW GAS LINE 16) ALL PAINT, FUEL, 4 CONSTR, PRODUCTS, ETC. TO BE STORED IN A COVERED LOCATION AWAY FROM SIDEWALKS 4 DRAIN INLETS. 11) PORTABLE TOILETS MUST BE KEPT OFF THE STREETS, SIDEWALKS 4 9 LEAST 50' FROM THE NEAREST DRAIN INLET, 18) ALL TRASH MUST BE COLLECTED 4 STORED PROPERLY, NO WASTE CONSTR, MATERIALS 4 CONTAINERS TO COME IN CONTACT w/ RAINFALL or STORM WATER RUNOFF. IS) AFTER ALL B,M,F,s ARE IN PLACE A MAINTENANCE PROGRAM MUST BE DEVELOPED TO INSURE IT'S CONTINUED EFFECTIVENESS. NEW UNDER GROUND ELEC. LINE EXIST, GARAGE LL R -B R ADJACENT RE -BAR LAPS TO BE STAGGERED A MINIMUM OF 5'0". 3, RE -BAR IN CONCRETE FOOTINGS TO HAVE A MIN, COVERAGE OF 3", RE -BAR TO BE CENTERED IN 4" CONCRETE SLABS, 4, RE -BAR TO BE CLEAN 4 ACCURATELY SECURED IN POSITION BEFORE 4 DURING CONCRETE PLACEMENT, EXIST, J SEPTIC TANK EX, ELEC, METER% EXISTING HOUSE NEW METER -, PANEL \ EX, OVER HEAD ELEC, LINE EX. GRAVEL DRIVEWAY SITE PLAN EX. POWER POLE EX, POWER POLE RECEIVED JUL I E 2Dil TRS AND AZ;SOCi RTES ae OWNER : DANIEL 4 COURTNEY WEBB LEGAL• ...A ,Ela 'i } 6 Cq 2593 W. SACRAMENTO AVE, Qj CHICO , BUTTE CoQ, , CAI A, PI "042 -160 -OI J PERMIT #i (P BUTTE COUNTY DEVELOPMENT SERVICES rO, V REVIEWED FOR CODE COMPLIANCE 5Q. FT, CALC5. DATE Z 1 gY -r-(L� `�OD� ;�N���'S1� } Qj HOUSE = 2884 SQ, FT. APPLICABLE CODES - 2016 CBG, JCRV CMG, GPC, GEC, GARAGE = ISS SQ, FT, CFC, CEnC, Ca, Green Building REAR PATIO - = 3S9 SQ, FT, Standards Code INCLUDING STOR. U BUILDING USE RESIDENCE CLOSET � a OCCUPANCY GROUP- R3 =GAR ;gip 00,11; 1-;�1, FRONT PORCH -- 84 SQ, FTI TYPE OF CONST, V -B, JUL Lry . 5 2;;",i Q3 ` FIRE SPRINKLERS REQUIRED 0 NO, OF STORIES 1 TRIG AND ASSOCIATES ae DRAWN 13 DJC DATE JUL 10 2317 JOB NAME DANIEL WEBe SHEET A 13 o� 4 SHEETS ® r N 0 tJ r � Cq U Qj (P rO, V O O Qj L � � v L U o 0 O Q3 ` 0 � V � 93 93 V � Qj Qi 0 U Q Q) Q qb 0 M � O }- C" cv � s � Q- �1 Q o e DRAWN 13 DJC DATE JUL 10 2317 JOB NAME DANIEL WEBe SHEET A 13 o� 4 SHEETS ® r N 0 tJ r � Qj rO, V O O Qj 0 } L � 0 O Q3 ` � • iU U E3 U Qj Qi 0 U Q qb DRAWN 13 DJC DATE JUL 10 2317 JOB NAME DANIEL WEBe SHEET A 13 o� 4 SHEETS ® r N 0 tJ r � T 8x12 EXPOSED HDR. /8x12 EXPOSED HDR. OPEN OPEN OPEN OPEN TELEVISION O NOTES : 8x12 FLAT MANTLE ® SEISMIC - PLF 2(00 T w/ CUSHION FLOOR PLAN 2884 5Q. FT. SEAT w/ CUSHION FAMILY RM. - 5HEAR WALL 5CHEDUL E SHEAR WALL AA NOTES : 1) OVER DOUGLAS FIR STUDS 9 16" 0/C. SEISMIC - PLF 2(00 2) ALL PANEL. EDGES BLOCKED w/ 2x FRAMING . U.O.N. Qj WIND - PLF 335 3) VERTICAL FRAMING FOR EDGE NAILING 6 ABUTTING PANELS TO BE 3/8" PLYWOOD C D X or EXT, 085 1,2 1 - SIDE 44 POST or 2-2x STUDS w/ 2 -ROWS I(od SINKERS f 12" 0/C FULL HEIGHT. 4) IF NAIL GUN IS USED , NAILS TO HAVE EDGE NAILING 4 Sd (O" O A FULL HEAD. 4 FIELD NAILING Sd 12° 5) TO BE INSTALLED S EACH END OF TRUSS. SILL PLATEEACH 1 I/2° THICKNESS (o) ANCHOR BOLT WASHERS TO -5E `f 3 SQ. x 1/4 THICK �SL PLS EWE 5 TRUSS TO PLATE SIMP, H-1 CODE COIV, JUL 2 5 2 ANCHOR BOLT b 5/8" 10 52" SPACING 1/2" 9 36" D "LIANCE . it KO AND A.SSOCL'ATES ® DRAWN DJC DATE JUL 10 2017 JOB NAME DANIEEL. WEEKS SHEET rq Of= 4 SHEETS in Cn U Qj r = U O �v O Lcu � ,r O :3 0 • 0 � V � ,� 93 93 93 U U Q) O 1L �— Nmm ca U Q 03 0 a' cz OE3 0 — � M Q) O � N CQ s B1 Q 0 D ® DRAWN DJC DATE JUL 10 2017 JOB NAME DANIEEL. WEEKS SHEET rq Of= 4 SHEETS in Qj U O �v O � � ,r O :3 0 • U 0 � U Q) O 1L �— Nmm U Q ® DRAWN DJC DATE JUL 10 2017 JOB NAME DANIEEL. WEEKS SHEET rq Of= 4 SHEETS in w J I 0 Fal s cl u Le 00 12 If FOOTING R 1z, ol FOOTING 4" CONC, SLAB 4" SAND BASE "4 TOP 4 BOTTOM SHOT PIN C•] iz" FOOTING 4" CONC, SLAB 4" SAND BASE *4 TOP 4 BOTTOM 2x4 P. T. H. F. SILL W/ 1/2" DIA, x 12" A. B. 3" SQ, x 1/4" s (ot" 0/C - U. 0, N. WASHER 4" CONC. SLAB o � 4" SAND BASE c�I? "4 TOP ¢ BOTTOM 12, FOOTING FOUNDATION PLAN I li-iloll FOUNDATION NOTES % 1. THIS FOUNDATION IS A "DOUBLE POUR" SYSTEM . 2. ALL EXTERIOR SLABS TO HAVE 2% MIN. SLOPE AWAY FROM STRUCTURE , AND "3 BARS m 24" 0/C EACH WAY . 3. CONCRETE SUB -CONTRACTOR TO VERIFY ALL DIMENSIONS BETWEEN FOUNDATION PLAN 4 FLOOR PLAN PRIOR TO POURING CONCRETE, 4. SUB GRADE TO BE SATURATED w/ WATER TO A DEPTH OF 12" TO 18" PRIOR TO POURING CONCRETE . S. HOUSE 4 GARAGE SLABS TO HAVE TOOLED JOINTS OR CRACK CONTROL STIPS . REVIEWED 6, PROVIDE 10 MIL. VAPOR BARRIER UNDER HOUSEDR CODE COMPLIANCE 4 GARAGE SLABS 4 COVER w/ 2" MIN, OF SAND • JUL 2 5 2017 TRI3 ANID ASSOCIATES o e Chi U r —= (P 75 rn Q) (P I C4 O L � _co U On� U o L U U �, 0 � U rn � U •— U L co Q) QC Q Q) � O� 0 -d M Q) 0 � N m A. - A— 0— Q) o) Q El a o V rO, V O O Q) I C4 O 0 On� Q] L U U �, cA 0 � U U •— % QC ® DRAWN DJG DATE JUL 10 2617 JOB NAME DANIEL WE 51B SHEET OF 4 SHEETS it F13 1/2" DIA, SCHED, 40 41011 BLACK IRON PIPE III III DIA, SCHED. 40 21011 221011 8 0 BLACK IRON I✓2" DIA. I" DIA, 36611 PIPE SCHED. 40 SCHED. 40 21011 F/P = 40K BTU BLACK IRON BLACK IRON 25,6" PIPE PIPE 111 DIA, 101011 SCHED, 40 3810" REGUTATOR BLACK IRON 3/4" DIA, PIPE SCHED. 40 DRYER = 22K BTU BLACK IRON RANGE --14K BTU 100' UNDER GROUND PIPE W/H -- 200K BTU TO L/P TANK .CA51PDAM 336,000 TOTAL PROPOSED BTU's 125' of 1" DIA, PIPE WILL. ALLOW 349,000 BTUs AS PER NFPA 54: TABLE 63(d) �PR��'CS�1�i�IP� CALLS. 2X8 FAC a 2x4,6 24" 0/C o� 114'± of 1" DIA. SCHED, 40 BLACK IRON PIPE, 20'± of 3/4" DIA, SCHED, 40 BLACK IRON PIPE. 44'± of 1/2" DIA. SCHED. 40 BLACK IRON PIPE, Y�NTING,DIAGRA 13/4" x 1/2" CROWN �16d m 3" 0/G --H E. N 7 P�A1E LINE SHEAR WALL SHEAR 1)TL-- TRUSS 0 24" 0/C .nX - I6 0/C 2X(0,6 1611 0/C O 6x12 HDR, N 11011 [4 11 PORCH ENTRY 2x4 0 16" 0/C I/A"-II n" ad 104" 0/0 STAGGERED y 2x4 50LID BLKCs, E. N� SINKERS To rRuss 2x4 is 24" 0/C 16d SINKER 2 - Ibd 51NKER5 e 4" 0/G TO TRUSS STAGGERED E. 1x4 SOLID BLKG, E. N.� SHEAR WALL SMEAR DTA. 40 ,5 1/2"x 11 1/81, V -LAM HDR. OF ARCH 12 �6 4" CONC. SLAB TRUSS 6 24" 0/C SECTION 1/411:11 oil FAMILY n .LEFT - 1/811 = 11 0" ad is b11 0/C TRUSS 6 24" 0/C' /L610 -0 24" 0/C PLATE LINE E, N: SHEAR WALL - i+nt,�fl C� 11111.1 tL REAR I/All-11n11 ,0 -j -, ill ni,- SHEAR DTL-- SHEAR [)TL# SHELF - TYP 2x4 0- 16, 0/C 1/2" PLYWD, w/ TECH SHIELD RADIANT BEARIER t 13/4"x 1/2" CROWN STAPLES 6" / 12" 0/C - UNBLOCKED �6 HDR. 5 1/2"x 11 1/8" V -LAM BM, 2x4 0 PATIO ---2x( 6 1611 0/C WF -GI- V1iItGGV - mT 1 1111, F F%V 1 I !_/\ 1 i..1�I V 1� I ♦•r'1�/ I J_I. EARTH d 2" FROM SLAB FRONT - 1/8" = 1' 0" ATTIC VENT GALIC5., 50% OF READ, VENTING TO BE IN THE UPPER PORTION OF ATTIC . (UPPER PORTION IS 3'0" MIN. ABOVE THE EAVE VENTS.) ATTIC -- 4161$0, FT. = 300 = 13.89 $Q, FT. -1 -- 19,84 $Q, FT, TOTAL REQUIRED VENTING . PROVIDE M2 SQ, FT, OF 3 1/2"x 20" HIGH DORMER VENTS . PROVIDE 9,92 SQ, FT. OF 4"x CONT, SAVE VENT AROUND ad 6 611 0/C is STRUCTURE , SHEAR WALL ONLY 2x4 SOLID BLKG, g � PROVIDE 1" AIR SPACE BETWEEN INSULATION 4 ROOF SHTG, AS PER CRC 1203,2 SHEAR WALL ONLY GUTTER SIMP. H1 CLIP RoOF NoTE6 E. N, TYP, Q ALL 1, ROOF PLYWOOD TO BE 1/2" CDX w/ TECH SHIELD TRUSSES RADIANT BARRIER or EQ. 4 13/4" x 1/2" CROWN 2x6 10 16" 0/C STAPLES tv 611 / 12" 0/C . STAPLE CROWNS TO BE 2x4 6 24" 0/C IN LINE w/ FRAMING MEMBERS . CONT. VENT --$HEAR WALL 2, NAIL ROOF SHTG, INTO DRAG TRUSSES w/ EXT, PLASTER ad 9 6" 0/C OVER FULL LENGTH OF TRUSS. 3, PROVIDE H1 CLIP 6 EACH END OF ALL TRUSSES. COMPOITIO(0 6HEAR DTLI 4, INSTALL AS PER CRPROVIDE CLASS 11C TABLES501.1 SHINGLES 5, FASTENERS FOR ROOF COVERING TO BE CORROSION RESISTANT . CRC 1501 . 11'0 3/4" PLATE DRAG TRUSS JOID DRAG TRUSS FO1D DRAG TRUSS C08D w/ ad 0 6" 0/C W/ 841 @ 6" 0/Cw/ ad's 6" 0/C SHTG, TO TRUSS SHTG, t0 TRUSS SHtG, t0 TRUSS w/ DRAG -- 4K w/ DRAG -- 4K _-� N \� 'Q w/ DRAG - 4K 9'0 3/4" PLATE ----p --- --------------- -- :Nlb ----------DSC5 DSC5PLATE 3/411 ---- — ---- - --- PLATE DSC5 N 8 6:12 6 N N 0 � 4 tiA SK� � � � Y 4 RIDGE �`�' � 4 ' 6:12 y 6:12 yo DRAG ad � 6u 0/C SS OSD „--- LIGHT I SHTG, TO TRUSS 4 4\e COMP w/ DRAG = 4K 11`0 3/4" PLATE RIDGE N ,SHINGLES ;-----------------; RIDGE y 6:12 RIDGE 11 t--, rO �Q 110 3/4 1 I SKY 6 . 12 HEAT PUMP 1 1 1 LOCATION 1 A• A• I X , RIDGE PLATE LIGHT O ' ----' I 110 3/ 1 II 6 : 12���r 6 ; PLATE J���' 110 3/4 4 w PLATE 1 o -6' 2 v� L 9'0 3/4" PLATE 4 ----p---- -- u, 4 4" R �1 i11'03/4" PLATE 1101 3/4 PLATE - 6:12 6:12 2,0 ---- - - TYP, L'i -------- ---- =7 --N7 I II 5 5 9 0 3/4 4 4 PLATR:-VIEWED SIMILAR FOR CODE COMPLIANCE RJUL 2 5 2017OOF �NO,;IATF--S pit. A . � ,�� 1/811 = II 011 k O � O � v 0 � F (P c� Qj L � � U L U o .rV 0 O Q) 0 � V U .� CA � U U V cu U Q � Q 15 m � O� 0 � Q o � N Dl Q) Q re O � t. 0 � F Qj � � O L 0- :3 0 O Q) � U .� CA � U U Q 15 m DRAWN DJC DATE JUL 10 2017 JOB NAME DANIEL LUMB SWEET r^ : ® OF: 4 SWEETS v d