Loading...
HomeMy WebLinkAboutB17-1250 039-220-044BUTTE COUNTY AREA DEPARTMENT OF DEVELOPMENT SERVICES 5 INSPECTION CARD MUST BE ON JOB SITE 24 Hour Inspection Line (IVR) : 530.538.4365 (Cut off time for inspections is 3pm) Development Services cannot guarantee inspections on the date requested Office: 530.538.7601 Fax:530.538.7785 www.ButteCountv.net/dds Permit No: B17-1250 Issued: 6/21/2017 APN: 039-220-044 Address: 10306 FIMPLE RD, CHICO Owner: J H MCKNIGHT RANCH INC Permit Type: SOLAR ROOF -RES Description: SOLAR ROOF - RES (14.04KW) Flood Zone: None SRA Area: No Front: Centerline of Road: Rear: SRA: Street: AG: Interior Total Setback from Centerline of Road: ALL PLAN REVISIONS MUST BE APPROVkD BY THE COUNTY BEFORE PROCEEDING I Inspection Type IVR INSP DATE Setbacks 131 Foundations / Footings 111 Pier/Column Footings 122 Eufer Ground 216 Masonry Grout 120 Setbacks 131 Do Not Pour Concrete Until Above are Signed Pre -Slab 124 Gas Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing 149 Underfloor Ducts 319 Shear Transfer 136 Under Floor Plumbing 412 Under Slab Plumbing 411 Blockin /Unde ini❑ 612 Tiedown/Soft Set System 611 Do Not Install Floor Sheathing or Slab Until Above Signed Shearwall/B.W.P.-Interior 134 ShearwallB.W.P.-Exterior 135 Roof Nail/Drag Trusses 129 417 Manometer Test Do Not Install Siding/Stucco or Roofing Until Above Signed Rough Framing 153 Rough Plumbing 406 Rough Mechanical 316 Rough Electrical 208 4 -Way Rough Framing 128 Gas Piping House 403 Gas Test House 404 Shower Pan/Tub Test 408 Do Not Insulate Until Above Signed Permit Final 802 Electrical Final 803 Mechanical Final 809 Plumbing Final 813 Fire Sprinkler Test or Final 702 Swimmin2 Pools M Inspection Type IVR INSP DATE T -Bar Ceiling 145 Stucco Lath 142 Swimmin2 Pools Setbacks 131 Pool Plumbing Test 504 Gas Test 404 Pre-Gunite 506 Pre -Deck 505 Pool Fencing/Alarms/Barriers 503 Pre -Plaster 507 Manufactured Homes Setbacks 131 Blockin /Unde ini❑ 612 Tiedown/Soft Set System 611 Permanent Foundation System 613 Underground Electric 218 Sewer 407 Underground Water 417 Manometer Test 605 Continuity Test 602 Skirting/Steps/Landings 610 Coach Info Manufactures Name: Date of Manufacture: Model Name/Number: Serial Numbers: Length x Width: Insignia: Finals Public Works Final 538.7681 Fire De artment/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final "PROJECT FINAL I I Tor 7- 7 'Project Final is a Certificate of Uccupancy for (Residential Unly) PERMITS BECOME NULL AND' VOID 1 YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A 1 YEAR RENEWAL 30 DAYS PRIOR TO EXPIRATION BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES; BUILDING PERMIT 24 HOUR INSPECTION (IVR)#:530.538.4365 OFFICE #: 530.538.7601 FAX#:530.538.7785 www.ButteCounty.net/dds M PROJECT INFORMATION,, 3r. Site Address: 10306 FIMPLE RD Owner: Permit No: B 17-1250 APN: 039-220-044 J H MCKNIGHT RANCH INC Issued Date: 6/21/2017 . By JMD -Permit type: MISCELLANEOUS P O BOX 3070 Subtype: SOLAR ROOF -RES CHICO, CA 95927 Expiration Date: 6/21/2018 ' Description: SOLAR ROOF - RES (14.04KW) Occupancy: Zoning: Contractor Applicant:. Square Footage: 00 ALTERNATIVE ENERGY SYSTEMS INC ALTERNATIVE ENERGY 13620 HWY 99 - CHICO, CA 95973 5303456980 Contractor (Name) ALTERNATIVE Building Gafi4ge RemdO'Addn 13620 HWY 99 CHICO, CA 95973 Other ' Porch/Patio Total 5303456980 0 0 0. RACTOR'S DECLARATION • 9 OWNER / BUILDER DECLARATION State Contractors License No. / Class / Expires I hereby affirm under penalty of perjury that I am exempt from the Contractors' Slate License Law for 853351 / C10 / 1/31/2019 the reason(s) indicated below by the checkmark(s) I have placed next to the applicable item(s) (Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, I HEREBY AFFIRM UNDER PENALTY OF PERJURY that I am licensed under provisions of Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license in full force and effect. - X Contractor's Signature 9 improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the i. permit to file a signed statement that he cr she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt from licensure and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): Date I, as owner of the property, or my employees with wages as their sole compensation, will do U all of or U portions of the work, and the structure is not intended or offered for sale WORKERS' COMPENSATION DECLARATION I HEREBY AFFIRM UNDER PENALTY OF PERJURY one of the following declarations: a1 have and will maintain a certificate of consent to self -insure for workers' compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Cade, for the performance of the work for which this permit is issued. Policy No. ❑I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier. CYPRESS Policy NumbAi wingi SS't9 Exp. [$f�201a ElI certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of Califomia, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. X Signature Date WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY DECLARATION= I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Section 3097, Civil Code). Lender's Name and Address Lenders Name & Address City State Zip (Section 7044, Business and Professions Code: The Contractors' Slate License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner -Builder will have the burden of proving that it was not built or improved for the purpose of sale.). ' I, as owner of the property, am exclusively contracting with licensed Contractors to construct the project (Section 7044, Business and Professions Code: The Contractors' Slate License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a licensed Contractor pursuant to the Contractors' Slate License Law.). ❑I am exempt from licensure under the Contractors' State License Law for the following reason: Owner's Signature Date PERMIT APPLICANT DECLARATION By my signature below, I certify to each of the following: am U a California licensed contractor or L) the property owner' or (_) authorized to act on the property owner's behalf have read this construction permit application and the information I have provided is correct. ' I agree to comply with all applicable city and county ordinances and state laws relating to building construction:" I authorize representatives of this city or county to enter the above -identified property for inspection purposes. California. Licensed Contractor, Property Owner' or Authorized Agent": 'requires separate verification form "requires separate authorization form X Name of Permittee [SIGN] Print Date I FEE INFORMATION' , Total Fees: $446.00 Fees Paid: $446.00 Balance Due: (None) Job Value: $39,000.00 PROJECT OWNER:UCa�- i45_ 7T SAFFORD BEESON SURVIVING TRUSTER'S TRUST 10306 FIMPLE RD CHICO, CA 95928 APN:039.220.044 PH#:530.521.6288 EMAIL:chrisalexmck@att.net CONTRACTOR: ALTERNATIVE ENERGY SYSTEMS INC. 13620 HIGHWAY 99 CHICO, CA 95973 CSLB: 853351 C-10, C-46 BUILDING JURISDICTION: ASWILT _ f � *, AWI N INSTALL PHOTOVOLTAIC SOLAR SYSTEM ON A TRUSS ROOF, MOUNTED IN ACCORDANCE WITH ALL APPLICABLE BUILDING CODES SPECIFICALLY REFERENCING THE 2016 CALIFORNIA ELECTRICAL CODE/ 2014 NEC USING THE FOLLOWING SPECIFIC EQUIPMENT: 1. MODULES: SUNPOWER (39) SPR -X22 -360 -C -AC 14.04kW SYSTEM 713 SQFT COVERED 2. INVERTER(S): SUNPOWER (39) MODULE INTEGRATED 320W SITE MAP PAGE # CONTENT PV -1.0 PV -2.0 PV -3.0 PV -4.0 PV -4.1 PV -5.0 ATTACHMENT BUTTE COUNTY JUN 21.2017. DEVELOPMENT SERVICES Ri7-, V S SCOPE SITE PLAN ARRAY LAYOUT ELECTRICAL DIAGRAM LABEL DIAGRAM GENERAL NOTES MODULE SPECS INVERTER SPECS RACKING SPECS WIRE CALCS BUTTE COUNTY DEPT. OF DEVELOPMENT SERVICES. A' 7 COUNTY CENTER DRIVE - �.r .'N N� :p vets OROVILLE, CA 95965 a OFFICE#: (530) 538-7601 ,iro► _.`�'i''.''�'.' FAX#: (530) 538-2140 MON-FRI8AM-3PM INSPECTION LINE: (530) 538-4365 4%� REQUESTS PHONED IN BY 2PM WILL BE " , INSPECTED THE NEXT BUSINESS DAY L �,... ; ,p,,. via ��'i'rr"'i [t'P '•��� /~ ? �.x' `� �, u F. SAFFORD BEESON n o v 13620 HWY 99 -0 o �, m ; s SURVIVING TRUSTER'S TRUST Energy For Life CHICO, CA 95973 ` Cp n go10306 FIMPLE RD PHONE#: (530) 345 69 80 0.opCHICO, CA 95928 momFAX#: (530) 892-2360= cZ Alternative Energy Systems Inc. D APN:039.220.044 PH#:530.521.6288 design@solarenergyforlife.com v,r•-_:.. f .�,. Y r - f �„''j • � �YYy'r !- ' � REVISION LJLJ rl firm I (3 v 4 00 ,_ J T J� el ! ti �� �'� _ 'rf < � .1 1 J1 �T,a f i • 0) ILA Ol m 00 t0 i �t i .��r4 , �frirr •��J`. � � t W t1 R 2 w LLn Q s w .3 I. I ,7+ diJ z oil Z' + c o O Z 0 CL O a tn7 a v 00. Lf vi -) 5 a, E�' Fur, Im i kit ul al rlAl ro Qrrk •}xr Oui ri 64 ui 1c C7 ' /yam ' «l. -t", ' j,Lu a a ' J 'ov_) f- " 'i�...,.f A•Ite 00 00 N 1p r -i N o or m F- N = z a W N N J, a rn Z U (V LL LO 00 C3 u i ? Or -4 U Q SCALE 1" = 40'1114801 DATE MODIFIED 06/14/2017 DESIGNER B. AGUTAR PV -2.0 SITE PLAN ` ASwBUILT i Y 45'-3" DRAWINGS r> I a Un C In ' LEGEND" - DIRECT 5' PR ATTACHMENTS MAX VON CENTER61-011 - 10' PR 13 IN v v 0 e a a• ■ 0 vcerm 0 v Ole sr. O® v v r. v SAFFORD BEESON_ 13620 HWY 99 p oil ' SSURVIVING TRUSTERS TRUST EnergyFor0fe CHICO, CA 95973 a as `o -o e' 0ON po 2 10306 AMPLE RD -o �® PHONE#: (530) 345-6980 z5 GI:� In iV r♦ W -OA o JI® II:MO♦ 1 Pw0 ® �� o!g iF ♦ 0 ��i r♦ PV -41,",# ®S i 4r v rs�v♦ ®� r� ♦ ® �� �♦ e, g 0 t _ APN:039.220.044 PH#:530.521.6288 Alternative Energy Systems Inc. design@solarenergyforlife.com _♦ P.®♦ ® � i� v♦ ® F.�9 ♦ ®8 Pi� v♦ 0 del row �♦ d ® ®e ia� ®♦ %� v♦ �. v♦ land e is e a e e - RAFTERS 24" ON CENTER . ARRAY LAYOUT SAFFORD BEESON_ 13620 HWY 99 p ' SSURVIVING TRUSTERS TRUST EnergyFor0fe CHICO, CA 95973 `o -o po 2 10306 AMPLE RD -o �® PHONE#: (530) 345-6980 z5 o CHICO, CA 95928 FAX#: (530) 892-2360pA g 0 t _ APN:039.220.044 PH#:530.521.6288 Alternative Energy Systems Inc. design@solarenergyforlife.com A&BUILT AC -2 (1) 1" EMT w/ SERVICE VOLTAGE ♦ 13) #4 THWN-2 CU. &0 = 0 =2 - (1)#B THWN-2 CU. GRD. 120V=N-L2-L3=NAV . ®PAWINGS WIRE RUN: 30' NAV=N-L3-Ll=NAV IMAX: 65A I I l 1z I METER l I l AC -1 ' 12 I ON ROOF w/ 20A - I (6) TRANSITION CABLE AC -1 Ip WIRE RUN: S' (4) #10 - 2 WIRE NM CABLE CU. 240V IMP: 20A - WIRE RUN: 20' 20A (N)1'7, SA l I IMAX: 20A 1p - 1P l 240V 240V 12 l 20A l 1P I 240V ]UNCTION 20A I BOX 1P 240V 15A l 3 l 1P 1. 240V .x 70A l I 1P l (N)AC DISTRIBUTION PANEL l I 125A/ 1P/ 240V (39) PV MODULES/INVERTERS (E) AC SERVICE PANEL - SUNPOWER: SPR -E20 -327 -C -AC I 20OA/ 1P/ 240V 240V/117/1.33A I SCIR: 10,000 _ _ / METER#:1009741061 - - AC -MONITORING i �% (1)1/2"EMT w/ HWN-2 1LO /O RULE • - (2) #14 THWN-2 CU. & - (1)#14 THWN-2 CU. GRD. ` - WIRE RUN: 10' DOWNSIZE MAIN BREAKER IN ACCORDANCE TO NEC 2014 CAT -S, ARTICLE 705.12(D)(2)(3)(b) SUNPOWER PVSSX r MONITORING ROUTER , ELECTRICAL DIAGRAM m o N SAFFQRD BEESON 13620 HWY 99 m < o C m S SURVIVING TRUSTER'S TRUST Energy For Life CHICO, CA 95973 `- cDi a a p p o m 10306 PIMPLE RD ��/ _ M®O'. PHONE#: (530) 345-6980 z 3 s " 9 o s CHICO, CA 95928 ' FAX#: (530) 892-2360 O a n o Alternative Energy Systems Inc. p n APN:039.220.044 PH#:530.521.6288 design@solarenergyforlife.com AC PV ARRAY A CONNECT MAIN - VOLTS WARNING 3.UTILITY INTERACTIVE POWER FLOWING THROUGH THIS PANEL KW SOLAR GENERATOR AC OPERATING VOLTAGE: or, VAC/—PHASE WARNING PHOTOVOLTAI J C SYSTEM EQUIPPED DUAL POWER SUPPLY WITH RAPID SHUTDOWN PHOTOVOLTAIC SYSTEM • Per NEC 690.54, Interactive Point of Interconnection installed at all Electrical. Per NEC 705.10, Point of Connection, Distribution Panel covers that provide a path Located On Main Service Panel. from PV to Utility. AC PHOTOVOLTAIC DISCONNECT FOR UTILITY OPERATION PerrNEC 690.14, Disconnection means at the single AC Disconnect or Main Breaker. - SOLAR BREAKER DO NOT RELOCATE Solar breaker label @ any breaker passing Bi -Directional Power -LABEL DIAGRAM SAFFORD BEESON o c' 13620 HWY 99 I A SURVIVING TRUSTER'S TRUST fnergy'For&Ae:5 CHICO, CA 95973 Ah- 0 10306 FIMPLE RD PHONE#: (530) 345-6980 z 2 > c, V M FAX#: (530) 892-23 CHICO, CA 95.928 60 Alternative Energlysyitems Inc. T APN:039.220.044 PH#:530.521.6288 design @sola renergyforlife.coin N71 F71 LJ-NLJNNN VOLTS WARNING 3.UTILITY INTERACTIVE POWER FLOWING THROUGH THIS PANEL KW SOLAR GENERATOR AC OPERATING VOLTAGE: or, VAC/—PHASE WARNING PHOTOVOLTAI J C SYSTEM EQUIPPED DUAL POWER SUPPLY WITH RAPID SHUTDOWN PHOTOVOLTAIC SYSTEM • Per NEC 690.54, Interactive Point of Interconnection installed at all Electrical. Per NEC 705.10, Point of Connection, Distribution Panel covers that provide a path Located On Main Service Panel. from PV to Utility. AC PHOTOVOLTAIC DISCONNECT FOR UTILITY OPERATION PerrNEC 690.14, Disconnection means at the single AC Disconnect or Main Breaker. - SOLAR BREAKER DO NOT RELOCATE Solar breaker label @ any breaker passing Bi -Directional Power -LABEL DIAGRAM SAFFORD BEESON o c' 13620 HWY 99 I A SURVIVING TRUSTER'S TRUST fnergy'For&Ae:5 CHICO, CA 95973 Ah- 0 10306 FIMPLE RD PHONE#: (530) 345-6980 z 2 > c, V M FAX#: (530) 892-23 CHICO, CA 95.928 60 Alternative Energlysyitems Inc. T APN:039.220.044 PH#:530.521.6288 design @sola renergyforlife.coin ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE 2014 NATIONAL ELECTRIC CODE (NEC), OR LOCAL MUNICIPAL CODE, AND FIRE DISTRICT REGULATIONS. 1. ALL EQUIPMENT SHALL BE LISTED AND LABELED PER RECOGNIZED ELECTRICAL TESTING LABORATORY AN INSTALLED PER THE LISTING REQUIREMENTS AND THE MANUFACTURER'S INSTRUCTIONS. 2. ALL INVERTERS SHALL BE IEEE 929 COMPLIANT AND SHALL BE INSPECTED BY LOCAL UTILITY BEFORE COMMISSIONING, TESTING, AND OPERATION OF THE SYSTEM. 3. ALL OUTDOOR EQUIPMENT SHALL BE MINIMUM NEMA 3R, INCLUDING OUTDOOR MOUNTED TRANSITION BOXES, COMBINER BOXES, AND SWITCHES. 4. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NECART.250,690. 5. NEC. ART. 690.9(A). ALL CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE OVERCURRENT DEVICES LOCATED SO AS TO PROVIDE OVERCURRENT PROTECTION FROM ALL SOURCES. 6. NEC ART. 690.18. DUE TO THE FACT THAT PV MODULES ARE ENERGIZED WHENEVER THEY ARE EXPOSED TO LIGHT, PV CONTRACTOR SHALL DISABLE THE ARRAY DURING INSTALLATION AND SERVICE BY SHORT CIRCUITING, OPEN CIRCUITING, OR COVERING THE ARRAY WITH AN OPAQUE COVERING. 7. PHOTOVOLTAIC SYSTEM SHALL BACKFEED THE DISTRIBUTION SYSTEM ON SITE PER THE REQUIREMENTS OF NEC ART.690.64(B). ALL BACKFEED BREAKERS SHALL BE IDENTIFIED AS SUCH AND SHALL BE SECURED IN PLACE BY ADDITIONAL FASTENER PER THE REQUIREMENTS OF NEC 408.16(F). 8. FALL ARREST PROTECTION PER OSHA REQUIREMENTS SHALL BE PROVIDED FOR ALL ROOF WORK. 9. ALL CONDUCTORS AND TERMINATIONS SHALL BE RATED FOR 75° C MINIMUM. 10. NEC ART. 690.14. -SEE SHEET RE -4.1 FOR LABEL DIAGRAM 11. NEC ART. 690.53. -SEE SHEET RE -4.1 FOR LABEL DIAGRAM 12. NEC ART. 690.17. EACH AC DISCONNECT SHALL ALSO BE LABELED WITH: "WARNING! -ELECTRICAL SHOCK HAZARD -DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIZE MAYBE ENERGIZED IN THE OPEN POSITION". 13. GROUNDING OF ALL DWELLINS SHALL BE CONFIRMED. 14. CONTRACTOR TO PROVIDE GROUND FAULT PROTECTION FOR ROOF MOUNTED PHOTOVOLTAIC ARRAYS LOCATED ON DWELLINGS PER 2014 NEC ART.690.17. 15. WHERE MORE THAN ONE NOMINAL VOLTAGE SYSTEM EXIST, THE DIFFERENT SYSTEMS SHALL BE IDENTIFIED BY PHASE AND SYSTEM PER 2014 NEC ART.210.41) 16. PROVIDE AN ACCESSIBLE DISCONNECT DEVICE THAT IS LOCKABLE IN OPEN POSITION AND IS LOCATED WITHIN 10'-0" OF THE METER PER LOCAL ELECTRICAL UTILITY REGULATIONS. 17. PHOTOVOLTAIC SOURCE CURRENTS MUST BE RATED AT BOTH 125% OF THE PARALLEL MODULE AND AT A CONTINUOUS LOAD OF ANOTHER 125% FOR A TOTAL OF 156% OF THE LOAD. 18. PROVIDE PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECT MEANS IF THEY ARE NOT IN THE SAME LOCATION PER 2014 NEC ART.690.56. 19. INSTALLATION OF PV PANEL ARRAYS SHOULD RESIST SLIDING AND POP-UP RESULTING FROM SEISMIC EVENTS AND SHOULD COMPLY WITH CBC SECTION 1613A AND ASCE STANDARD 7-05, CHAPTER 13. 20. PV SYSTEM INSTALLER WILL BE RESPONSIBLE FOR FURNISHING AND INSTALLATION OF ALL RELATED EQUIPMENT, CABLES, ADDITIONAL CONDUITS, BOXES WIREWAYS AND OTHER ACCESSORIES NECESSARY FOR COMPLETE AND OPERATIONAL PHOTOVOLTAIC SYSTEMS. 21. PV SYSTEM CONTRACTOR SHALL COORDINATE ALL THE WORK WITH THE ENGINEER, THE CONSTRUCTION MANAGER AND ALL OTHER CONTRACTORS TO ENSURE THAT PV SYSTEM IS INSTALLED AS SPECIFIED IN THESE DRAWINGS. 22. DRAWING IN GENERAL OR DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF THE EQUIPMENT AND WORK INCLUDED. THE INTENTION OF THE DRAWING IS TO INDICATE SIZE, CAPACITY, APPROXIMATE LOCATION AND GENERAL RELATIONSHIP, BUT NOT EXACT DETAIL OR PHYSICAL PLACEMENT. . 23. FIELD VERIFIES EXACT AIC RATING REQUIRED OF THE MAIN SWITCHBOARD FROM LOCAL UTILITY. 24. A PV SYSTEM WITH MULTIPLE. INVERTERS, WHERE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, WILL HAVE A DIRECTORY CREATED FOR EACH LOCATION. AS PER 2014 NEC 690.5(H) AND IN ACCORDANCE WITH 2014 NEC 705.10. 25. A NON FOLDING LADDER WILL BE IN PLACE AND SECURED TO THE ROOF TO PROVIDE ACCESS FOR ALL INSPECTIONS. ALL BOXES WILL BE OPENED UPON REQUEST. 26. SMOKE AND CARBON MONOXIDE ALARMS WILL BE INSTALLED IN ACCORDANCE WITH CRC R314 R315 SAFFORD BEESON 13620 HWY 99 Z A D9 m SURVIVING TRUSTER'S TRUST F.nergyForf lfe CHICO, CA 95973 z G a o n -.00 � 10306 FIMPLE RD ���� PHONE#: (530) 345-6980 ®l�ae►J z p CHICO, CA 95928 FAX#: (530) 892-2360 p n A D Y o APN:039.220.044 PH#:530.521.6288 Alternative Energy Systems Inc. design@solarenergyforlife.com Design -Driven Advantages #1 module aesthetics and efficiency' Unmatched module reliabilityz No electrolytic capacitors 25 -year Combined Power and Product Warranty 1 Maximize Value for Roof i Size system for roof, not string inverter ! Optimize performance of each module Expand Deployment Options Complex roofs and partial shading Small systems System expandability Simplify & Speed Installation Factory -integrated microinverter Robust, double -locking AC connectors Design flexibility offsite and onsite No DC string sizing process Fewer installation steps than competing systems Intuitive commissioning Component of Complete System j Built for use with SunPowerO InvisiMount1m i and the SunPower Monitoring System Superior system reliability and aesthetics Optimize System and Installation Efficiency SunPower", AC. Modules, which include a factory -integrated SunPower microinverter, provide a revolutionary combination of high efficiency, high reliability; and mcdule-level DC -to -AC power conversion. Designed specifically for use with SunPower.InvisiMount'll and the SunPol,ver Monitoring System, SunPower AC Modules enable rapid installation, best -in -class system aesthetics, and intuitive visibility into system performance. All this comes with the best Combined Power and Product Warranty. � S y +t . " v" a 9 � 1 i �' i4 F i � , � • i +,� . �� 'ri� i '. °+P. �"j"�;t %•. S � _�.-. . .er: f�i 4• •` p � aft` a _ ,�, t� 64 f� ��t �r +y,�` _ - . DdtaShee[ ro -�' ��` .rT�ti :,.y 5 ., .L:� ,� t' � � �� P � •� � 1\ - X SERIES Optimize System and Installation Efficiency SunPower", AC. Modules, which include a factory -integrated SunPower microinverter, provide a revolutionary combination of high efficiency, high reliability; and mcdule-level DC -to -AC power conversion. Designed specifically for use with SunPower.InvisiMount'll and the SunPol,ver Monitoring System, SunPower AC Modules enable rapid installation, best -in -class system aesthetics, and intuitive visibility into system performance. All this comes with the best Combined Power and Product Warranty. � S y +t . " v" a 9 � 1 i �' i4 F i � , � • i +,� . �� 'ri� i '. °+P. �"j"�;t %•. S � _�.-. . .er: f�i 4• •` p � aft` a _ ,�, t� 64 f� ��t �r +y,�` _ - . DdtaShee[ ro -�' ��` .rT�ti :,.y 5 ., .L:� ,� t' � � �� P � •� � 1\ 1 • fi f lHighest of over 3,200 silicon solar panels, Photon Module Survey, Feb..201 A =sl rank in "PV Adodule Durabilia/ Initiative Public Report." Fraunhofer CSE, Feb 2013. Frye out of the rop eight largest manufacturers were tested. Campeau, 7 et al. "SunPower Module Degradation Rate," SunPower wnite paper, Feb 2013. See vrnw.sunpower.com/acts for details. =Siandard Test Conditions (1000 With' irradiance, AM 1.5; 251 Q. NREL calibration standard: SOUS current LACCS FF and voltage. Al DC volage is fully containec within the module. `lased on average of measured power values durir>g production. See www.sunpower.corn/facts for more reference information. For more details, see extended datasheet: wwvr.sunpower.mm/datasheets. Output @ 240 V (min./nom./max.) Output @ 208 V (min./nom./max.)' SPR -X22 -360 -C -AC Nominal Power (Pnom) -360W Power Tolerance -5/-0% Avg. Panel Efficiency4 22.2%t Temp. Coef. (Power) -0.300/o/'C Shade Tolerance ' Three bypass diodes Integrated module -level maximum power point tracking f lHighest of over 3,200 silicon solar panels, Photon Module Survey, Feb..201 A =sl rank in "PV Adodule Durabilia/ Initiative Public Report." Fraunhofer CSE, Feb 2013. Frye out of the rop eight largest manufacturers were tested. Campeau, 7 et al. "SunPower Module Degradation Rate," SunPower wnite paper, Feb 2013. See vrnw.sunpower.com/acts for details. =Siandard Test Conditions (1000 With' irradiance, AM 1.5; 251 Q. NREL calibration standard: SOUS current LACCS FF and voltage. Al DC volage is fully containec within the module. `lased on average of measured power values durir>g production. See www.sunpower.corn/facts for more reference information. For more details, see extended datasheet: wwvr.sunpower.mm/datasheets. Output @ 240 V (min./nom./max.) Output @ 208 V (min./nom./max.)' 211/240/264 V 183/208/229 V Operating Frequency (min./nom./max.) 59.3/60.0/60.5 Hz Output Power Factor (min.) 0.99 AC Max. Continuous Output Current @ 240 V AC Max. Continuous Output Current @ 208 V 1.33 A 1.54 A AC Max. Cont. Output Power 320 W DC/AC CEC Conversion Efficiency 96.0% Max. Units Per 20 A Branch Circuit'@ 240 V Max. Units Per 20 A Branch Circuit @ 208 V 12 (single phase) 10 (two pole) ' f lHighest of over 3,200 silicon solar panels, Photon Module Survey, Feb..201 A =sl rank in "PV Adodule Durabilia/ Initiative Public Report." Fraunhofer CSE, Feb 2013. Frye out of the rop eight largest manufacturers were tested. Campeau, 7 et al. "SunPower Module Degradation Rate," SunPower wnite paper, Feb 2013. See vrnw.sunpower.com/acts for details. =Siandard Test Conditions (1000 With' irradiance, AM 1.5; 251 Q. NREL calibration standard: SOUS current LACCS FF and voltage. Al DC volage is fully containec within the module. `lased on average of measured power values durir>g production. See www.sunpower.corn/facts for more reference information. For more details, see extended datasheet: wwvr.sunpower.mm/datasheets. Operating Temp. -40° F to +185° F (-40° C to +850 Q Max. Ambient Temp. 122' F (50' C) Max. Load Wind: 62 psf, 3000 Pa, 305 kg/m2 front & back Environmental Snow: 125 psi, 6000 Pa, 611 g/m2 front Impact Resistance 1 inch (25 mm) diameter hail at 52 mph (23 Frame m/S) f lHighest of over 3,200 silicon solar panels, Photon Module Survey, Feb..201 A =sl rank in "PV Adodule Durabilia/ Initiative Public Report." Fraunhofer CSE, Feb 2013. Frye out of the rop eight largest manufacturers were tested. Campeau, 7 et al. "SunPower Module Degradation Rate," SunPower wnite paper, Feb 2013. See vrnw.sunpower.com/acts for details. =Siandard Test Conditions (1000 With' irradiance, AM 1.5; 251 Q. NREL calibration standard: SOUS current LACCS FF and voltage. Al DC volage is fully containec within the module. `lased on average of measured power values durir>g production. See www.sunpower.corn/facts for more reference information. For more details, see extended datasheet: wwvr.sunpower.mm/datasheets. o • Warranties 25 -year limited power warranty 25 -year limited product warrant UL 1741, including compliance with applicable requirements of IEEE 1547 and IEEE 1547.1 FCC and ICES -003 Class B AC module Type 2 Fire Rated UL 2703 InvisiMountTM' Listing maintained Certifications when installed with this AC Module Class A Fire Rated when installed with Invisilvloun[', and when distance between roof surface and bottom of SunPower module frame is <- 3.5" (8.89 cm) Alternating Current (AC) Module designation j enables installation in accordance with NEC 690.6 PID Test 4 Potential -induced degradation free 1 1046 mm (41.2 in] 1558 mm (61.3 in] y) Please read the safety and installation instructions for details. Document # 516046 Rev C /LTR US Solar Cells 96 Monoc stalline IMaxeonO Gen III Front Front Glass High -transmission tempered glass with and - coating Environmental Outdoor rated Rating Frame Class 1 black anodized (highest AMNIA rating) Weight 45.5 lbs (20.6 kg) Max. Recommended' 1.3 in. (33 mm) Module Spacing o • Warranties 25 -year limited power warranty 25 -year limited product warrant UL 1741, including compliance with applicable requirements of IEEE 1547 and IEEE 1547.1 FCC and ICES -003 Class B AC module Type 2 Fire Rated UL 2703 InvisiMountTM' Listing maintained Certifications when installed with this AC Module Class A Fire Rated when installed with Invisilvloun[', and when distance between roof surface and bottom of SunPower module frame is <- 3.5" (8.89 cm) Alternating Current (AC) Module designation j enables installation in accordance with NEC 690.6 PID Test 4 Potential -induced degradation free 1 1046 mm (41.2 in] 1558 mm (61.3 in] y) Please read the safety and installation instructions for details. Document # 516046 Rev C /LTR US InvisiMouomponent Images Module* / Mid Clamp and Rail Mid Clamp End Clamp Rail & Rail Splice 0 • - • •?$-. 7 Warranties Component Material weight Mid Clamp Black oxide stainless steel AI51 304 63 g (2.2 oz) End Clamp Black anodized aluminum alloy 6063-T6 1 10 g (3.33 oz) Rail Black anodized aluminum alley 6005-T6 330 g/m (9 oz/fr) Rail Splice Aluminum alloy 6005-T5 330 g/m (9 ozlft) Ground lug Assembly 304 stainless (A2-70 boit; tin-plated copper lug) 106.5 g/m (3.75 oz) End Cap Black acetal (POM) copolymer 10.4 g (0.37 oz) 0 • - • •?$-. 7 Warranties Composition Shingle P,after Attachmenr Application Composition Shingle Roof Decking attachment Curved and Pat Tile Roof Attachment Certifications Universal Interface for Ccher Roof Attachments Is Module* / End Clamp and Pail Temperature -40° C to 90° C (-40° F to 194° F) Max. load 2400 Pa uplift 5400 Pa downforce Refer to'roof attachment hardware manufacturer's documentation `Nlodule frame that is compatible with the Invisihlount system required for hardware interoperability. 4 2015 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPO,VER logo, and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation. All ocher crademarks .ire the property of their r�!;pective owner. Specifications included in this datasheet are subject to change without notice. sunpower.com Document #509506 Rev 8 Warranties 25 -year product warranoy 5 -year finish warranty UL 2703 Listed Certifications Class A fire rating when distance between roof surface and bottom of SunPower module frame is s 3.5" Refer to'roof attachment hardware manufacturer's documentation `Nlodule frame that is compatible with the Invisihlount system required for hardware interoperability. 4 2015 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPO,VER logo, and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation. All ocher crademarks .ire the property of their r�!;pective owner. Specifications included in this datasheet are subject to change without notice. sunpower.com Document #509506 Rev 8 Y., GreenFasten'" GF1 Product Guide 1 5 Consult an engineer or go to www.ecofastensolar.com for engineering data. Installation Instructions with Compression Bracket 3 4a 4b 4c .1. Locate the rafters and snap horizontal and vertical lines to mark the installation position for each GreenFasten flashing. 2. Drill a pilot hole (1/4"diameter) for the lag bolt. Backfill with sealant. EcoFasten Solar recommends an EPDM mastic. 3. Insert the flashing so the top part is under the next row of shingles and pushed far enough up slope to prevent water infiltration through vertical joint in shingles. The leading edge of flashing must butt against upper row of nails to prevent turning when tourqued. See page 2.2 for vertical adjustment when leading edge of flashing hits nails in upper shingle courses. 4. Line up pilot hole with GreenFasten flashing hole. , 4a Insert the lag bolt through the EPDM washer, the top compression component bracket (L- 102-3, L-102-6*; SCL-101-3*, Z-101*, Conduit Mount Bracket*) and the gasketed hole in the flashing and into the rafter. - 4b Insert the lag bolt through the EPDM washer, the Comp Mount Slide compression bracket and the gasketed hole in the flashing and into the rafter. - 4c Insert the lag bolt through the SS washer, the third -party bracket, the EPDM bonded washer, the CP -SQ -Slotted compression bracket and the gasketed hole in the flashing and into the rafter. 5. Torque: The range is between 100-140 torque inch -pounds depending on the type of wood and time of year. The visual indicator for proper torque is when the EPDM on the underside of the bonded washer begins to push out the sides as the washer compresses. If using an impact wrench to install the fasteners be careful not to over torque the fastener. You may need to stop and use a ratchet to finish the install. *not pictured. }' �. 877-859-3947 EcoFasten Solar®AII content protected under copyright. All rights reserved. 7/24/2014 '1 EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 B2 8,153.700 B2 8,181.398 B2 8,166.713 B2 8,146.299 B2 8.209.914 B2 8,245,454 B2 8.272.174 132 8.225.557 132 2.1 .r ,r - •moi 1 5 Consult an engineer or go to www.ecofastensolar.com for engineering data. Installation Instructions with Compression Bracket 3 4a 4b 4c .1. Locate the rafters and snap horizontal and vertical lines to mark the installation position for each GreenFasten flashing. 2. Drill a pilot hole (1/4"diameter) for the lag bolt. Backfill with sealant. EcoFasten Solar recommends an EPDM mastic. 3. Insert the flashing so the top part is under the next row of shingles and pushed far enough up slope to prevent water infiltration through vertical joint in shingles. The leading edge of flashing must butt against upper row of nails to prevent turning when tourqued. See page 2.2 for vertical adjustment when leading edge of flashing hits nails in upper shingle courses. 4. Line up pilot hole with GreenFasten flashing hole. , 4a Insert the lag bolt through the EPDM washer, the top compression component bracket (L- 102-3, L-102-6*; SCL-101-3*, Z-101*, Conduit Mount Bracket*) and the gasketed hole in the flashing and into the rafter. - 4b Insert the lag bolt through the EPDM washer, the Comp Mount Slide compression bracket and the gasketed hole in the flashing and into the rafter. - 4c Insert the lag bolt through the SS washer, the third -party bracket, the EPDM bonded washer, the CP -SQ -Slotted compression bracket and the gasketed hole in the flashing and into the rafter. 5. Torque: The range is between 100-140 torque inch -pounds depending on the type of wood and time of year. The visual indicator for proper torque is when the EPDM on the underside of the bonded washer begins to push out the sides as the washer compresses. If using an impact wrench to install the fasteners be careful not to over torque the fastener. You may need to stop and use a ratchet to finish the install. *not pictured. }' �. 877-859-3947 EcoFasten Solar®AII content protected under copyright. All rights reserved. 7/24/2014 '1 EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 B2 8,153.700 B2 8,181.398 B2 8,166.713 B2 8,146.299 B2 8.209.914 B2 8,245,454 B2 8.272.174 132 8.225.557 132 2.1 A GreenFasten'" GF1 - Product Guide Installation Instructions - * Use for vertical adjustment when leading edge of flashing hits nails in upper shingle courses . Slide flashing up under shingles until leading edge 2. Remove flashing and cut "V"notch at marks where nail shafts engages nails. Measure remaining distance to adjust engaged leading edge of flashing the distance desired in Step 1. linclnno Notch depth not to exceed 2"length by 1/2"width. shingle Placement of"V" notch 3. Reinstall flashing with notched area upslope. shingle 4. Position notched leading edge underneath nail heads as shown. Nails beneath shingle AIMr i 877-859-3947 EcoFasten Solar" All content protected under copyright. All rights reserved. 7/24/2014- 2.2 EcoFasten Solar products are protected by the following U.S. Patents: 8.151,522 B2 8,153,700 B2 8,181.398 B2 8.166,713 B2 8,146.299 B2 8,209.914 B2 8,245.454 B2 8.272.174 B2 8,225.557 B2 T ik GreenFasten" GH —Product Guide Cut Sheets: GF1 F ' ... i - •- - moi- ,r - . . • Y - Y , = SECTION A -A - .. t1� 877-859-3947 EcoFasten Solar®All content protected under copyright. All rights reserved: 7/24/2014 3.1 h EcoFasten. Solar products are protected by the following U.S. Patents: 8.151 ^522 B2 8,153,700 82 8,181.398 B2 8.166,713 B2 8,146,299 B2 8.209.914 B2 8.245.454 B2 8.272,174 B2 8,225.557 B2 4' q &eenFasten- GF1 =. Product Guide - Cut Sheets: GF1;: 812' t i j� 1, - . • • a r r . ., - � . o _ 07 . �. 5 - �j._ ♦A r�r -5/64 r> 5 k�i w „� • DETAIL A. 4"SCALE: 2:1 ip lit VT r - ` Finish Options BILK = Matte Black. MLL =Mill Finish 4( 877-859-3947 EcoFasten Solar" All content protected under copyright. All rights reserved. 7/24/2014 _ , 3,2 f '` EcoFasten Solar products are protected by the following U.S. Patents: 8.151,522 B2 8.153,700 82 8.181,398 132 8.166.713 B2'8.146.2'99 132'8209.914 B2 8.245.454 132 8,272.174 B2 8,225.557 132 GreenFasten"GF1 — Product Guide Cut Sheets: Bracket Options - CP -SQ -Slotted � 1 � y A i _i � a - ,y' • -- 1.50 — .06 j 37■8�r: 2.00Ong a! n1 _ 0'0.38" _ .00 Z 0.50 1.00 0- 0.198±.01 X 82° At 1f . i • 2.00 }'. � v �k v. 877-859-3947 EcoFasten SolarlAll content protected under copyright. All rights reserved. 7/24/2014 _ 3.3 �" EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 132 8,153,700 B2 8,181.398 B2 8,166,713 B2 8,146.299 82 8,209.914 B2 8,245.454 B2 8.272.174 B2 8,225,557.82 f b � 46 SERRATION Cut Sheets: Bracket Options - SCL-101-3" 1/4"00 3 4„ f 1/ 16" R.005 _ 4 2X R.01 — –�— - 60.000 +.006 0 3/8"-.002 / 1 /8" Y - 0 .7/8" X 820 DETAIL A SCALE 3:1 877-859-3947 ' EcoFasten Solar" All content protected under copyright. All rights reserved. 7/24/2014 3.5 EcoFasten Solar products are orotected by the following U.S. Patents: 8.151.522 B2 8.153.700 B2 8.181.398 B2 8,166.713 B2 8,146.299 B2 8,209,914 B2 8,245.454 B2 8.272.174 B2 8.225.557 B2 GreenFasten" GF1 — Product Guide Cut Sheets: Bracket Options - L-1024' , 2X 3/8" l• ILI i�ISSS:Q 46 SERRATIONS rlf l 718„ e � R 1116.' - 16" �o r R.005. _ LO R.0 10 2 X R.01 , 60.00°.- „+- _006 3/8 .002 1 /8" 4 ; U 0.875 ±'.010 X.82 ° DETAIL SCALE3A 1 r t 877-859-3947 EcoFasten Solar" All content protected under copyright. All rights reserved. 7/24/2014 3•6 1 `�-` EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 132 8,153,700 B2 8,181,398 B2 8,166,713 B2 8,146.299 B2 8.209.914 B2 8.245.454 B2 8,272.174 B2 8,225.557 B2 . I - • X N _ 1 7/8.. e � R 1116.' - 16" �o r R.005. _ LO R.0 10 2 X R.01 , 60.00°.- „+- _006 3/8 .002 1 /8" 4 ; U 0.875 ±'.010 X.82 ° DETAIL SCALE3A 1 r t 877-859-3947 EcoFasten Solar" All content protected under copyright. All rights reserved. 7/24/2014 3•6 1 `�-` EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 132 8,153,700 B2 8,181,398 B2 8,166,713 B2 8,146.299 B2 8.209.914 B2 8.245.454 B2 8,272.174 B2 8,225.557 B2 . AC Circuit Ampacity Calculator - Meter #: i00974:1:0=61— Customer Name: SAFFORD BEESON SURVIVING TRUSTR'S TRUST Location: 10306 FIMPLE RD,_Chico, CA 95928 . Wire Note: AC-1 Description: INVERTER TO AC DISTRIBUTION PANEL r 4rglculation kWatts °-2.,40 VAC Split Voltage Configuration TRUE TL Inverter?, Minimum Wire and Conduit Size based on Voltage Drop and Ampacity 0 Minimum Ground Size Based on NEC A Minimum Ciruit Breaker/Fuse Size 10 Actual Ground Size Based on NEC 20.00 A Ampacity After Derate 10 Wire Size Based on Ampacity ' r30 A -0.496 % of Voltage Drop 10 _ Wire Size Based on Voltage Drop 30 A 16 A Circuit Ampacity 1 " Factor, r- Phases i• '0.96 Conditions of Use Derate Factor ' ° 16.67 A Minimum Conductor Ampacity Based on Conditions of Use 20.00 A Minimum Conductor Ampacity Based on 1.25 Rule Conditions'of Use r, �: - s t. '7v' a s 0.96 Derate Total ' 35 °C Temp Coef (ambient + Sunlight) 95 °F 0.96' Derate - 35 °C Ambient Temp 95 °F none Sunlight Exposure +- .` - "-' 32 °F "0 °C Temp adder 3 or less Number of Current Carrying Conductors. 1'' ,Derate applied to Temp Coefficient Voltage Drop; Allovaable.Tolgr-ance (Sol ar�Ge"neration 1%,.Dist_ribution 3%) 240 V Circuit Voltage 16 A Circuit Amps 1 24 Resistance - ' -� �: - 30 ft One Way Distance `10, ' Wire Size a 0.496 % of Loss Conduit Size (Conduit FiIIFCan Not be more .than 40%) f Y V None Conduit TypeLTHW 0.16 Wire Size Diameter #N/A Conduit Fill percentage ' 1 Conduit Size 0.16 _ Ground Wire Size Diameter #N/A Conauit Internal Diameter .+ 600 V System Voltage N-2 Wire Type L AC Circuit Ampacity Calculator Meter #T.,-.. 1009741061 Customer Name: SAFFORD BEESON 5URVIVING TRU,STR'S TRUST Location: 10306 FIMPLE RD, Chlco, CA 95928 Wire Note: AC-2 Description: AC DISTRIBUTION PANEL TO AC SERVICE PANEL Wire Calculation _ .r 12.48 kWatts• '240. VAC Split Voltage Configuration TRUE TL Inverter? 4 Minimum Wire and Conduit Size based on Voltage Drop and Ampacity ® Minimum Ground Size Based on NEC , 65.00 A Minimum Ciruit Breaker/Fuse Size' 1 8 Actual Ground Size Based on NEC 65.00 A Ampacity After Derate 4 Wire Size Based on Ampacity 95 A 0:1335 % of Voltage Drop 4 Wire Size Based on Voltage Drop -.x'95 A 52 A Circuit Ampacity 1 - Factor 1 Phases 0.82 Conditions of Use Derate Factor Y ' :63.41A Minimum Conductor Ampacity Based on Conditions of. Use 65.00 A Minimum Conductor Ampacity Based on 1.25 Rule Conditions of.Use x..7 0.82 Derate Total a 50 *C Temp Coef (ambient + Sunlight) 122 °F 0.82,' Derate " - .. - R 50 `C Ambient Temp - 122 'F none Sunlight Exposure - _ ; .'32 `F - 0" °C Temp adder 3 or less Number of Current Carrying Conductors 1" Derate-applied to Temp Coeficient Voltage Drop: Allowable-To eranee=(Solar Generation 1%, Distribut 3 _r-, 240 V . Circuit.Voltage 52 A Circuit Amps . 03.Q$ Resistance 10 ft One Way Distance "4'• Wire Size ` 0.1335 % of Loss - Conduit Size (Conduit Fill, Can Not be more-than 40%) EMT Conduit Type :0.317 Wire Size Diameter 31% Conduit Fill percentage 1 Conduit Size 0.212-' Ground Wire Size Diameter 0.868 "Conduit Internal Diameter 600 V System Voltage - THWN-2 Wire Type -