Loading...
HomeMy WebLinkAboutB17-1291 040-090-064BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES INSPECTION CARD MUST BE ON JOB SITE 24 Hour Inspection Line (IVR) : 530.538.4365 (Cut off time for inspections is 3pm) Develonment Services cannot Puarantee inspections on the date reauested Office: 530.538.7601 Fax: 530.538.7785 www.ButteCounty.net/dds Permit No: B 17-1291 Issued: 6/26/2017 APN: 040-090-064 Address: 1632 GARDEN RD, DURHAM Owner: MARKS RUSSELL T & ERIN P Permit Type: SOLAR ROOF -RES Description: SOLAR ROOF - RES (5.28KW) AREA 5 Flood Zone: AE SRA Area: No 9FTBACKS for Zoning, AG_ SRA_ PW Front: Centerline of Road: Rear: SRA: Street: AG: Interior Total Setback from Centerline of Road: ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING Inspection Type IVR INSP DATE" Setbacks 131 Foundations / Footings 111 Pier/Column Footings 122 Eufer Ground 216 Masonry Grout 120 Setbacks 131 Do Not Pour Concrete Until Above are Signed Pre -Slab 124 Gas Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing 149 Underfloor Ducts 319 Shear Transfer 136 Under Floor Plumbing 412 Under Slab Plumbing 411 Blockin /Unde inin 612 Tiedown/Soft Set System 611 Do Not Install Floor Sheathing or Slab Until Above Signed ShearwallB.W.P.-Interior 134 ShearwallB.W.P.-Exterior 135 Roof Nail/Drag Trusses 129 417 Manometer Test Do Not Install Siding/Stucco or Roofing Until Above Signed Rough Framing 153 Rough Plumbing 406 Rough Mechanical 316 Rough Electrical 208 4 -Way Rough Framing 128 'Gas Piping House 403 Gas Test House 404 Shower Pan/Tub Test 408 Do Not Insulate Until Above Signed Permit Final 802 Electrical Final 803 Mechanical Final 809 Plumbing Final 813 Fire Sprinkler Test or Final 702 Swimming Pools Inspection Type IVR INSP DATE T -Bar Ceiling 145 Stucco Lath 142 Swimming Pools Setbacks 131 Pool Plumbing Test 504 Gas Test 404 Pre-Gunite 506 Pre -Deck 505 Pool Fencing/Alarms/Barriers 503 Pre -Plaster 507 Manufactured Homes Setbacks 131 Blockin /Unde inin 612 Tiedown/Soft Set System 611 Permanent Foundation System 613 Underground Electric 218 Sewer 407 Underground Water 417 Manometer Test 605 Continuity Test 602 Skirting/Steps/Landings 610 Coach Info Manufactures Name: Date of Manufacture: Model Name/Number: Serial Numbers: Length x Width: Insignia: Finals Public Works Final 538.7681 Fire De artment/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final **PROJECT FINAL -rroject rinai is a Lermicate of Viceupancy for tKesiaennal unly) PERMITS BECOME NULL AND VOID 1 YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A 1 YEAR RENEWAL 30 DAYS PRIOR TO EXPIRATION BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT 24 HOUR INSPECTION (IVR)#:530.538.4365 OFFICE #: 530.538.7601 FAX#:530.538.7785 www. ButteCounty.net/dds Contractor Applicant. PROJECT INFORMATION RUSSELL T MARKS Site Address: 1632 GARDEN RD 1632 GARDEN ROAD . F Owner' Permit NO: B 17-1291 APN: 040-090-064 5306807331 MARKS RUSSELL T & ERIN P -+ Permit type: MISCELLANEOUS * -OWNER I BUILDER 1632 GARDEN RD Issued Date: 6/26/2017 By JMD Subtype: SOLAR ROOF -RES the reason(s) indicated below by the checkmark(s) I have placed next to the applicable item(s) (Section DURHAM, CA 95938 Expiration Date: 6/26/2018 Description: SOLAR ROOF - RES (5.28KW) State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and in full force and effect. - Occupancy: Zoning: Contractor Applicant. Square Footage. RUSSELL T MARKS RUSSELL T MARKS Building k GarOage Remdll/Addn 1632 GARDEN ROAD 1632 GARDEN ROAD . F 0 DURHAM, CA 95938 DURHAM; CA 95938 Other rPorch/Patio Total 5306807331 5306807331 0 t 0 0 -LICENSED CONTRACTOR'S DECLARATION * -OWNER I BUILDER DECLARATION :r Contractor (Name) State Contractors License No. /Class /Expires I hereby affirm under penalty of perjury that I am exempt from the Contractors' Slate License Law for RUSSELL T MARKS 701317 / C46 / 8/31/2018 the reason(s) indicated below by the checkmark(s) I have placed next to the applicable item(s) (Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, .improve, demolish, or repair any structure, prior to its issuance; also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' I HEREBY AFFIRM UNDER PENALTY OF PERJURY that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license i State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and in full force and effect. - Professions Code) or that he or she is exempt from licensure and the basis for the alleged exemption. X Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): 1 I, as owner of the property, or my employees with wages as their sole compensation, will Contractor's Signature Date do U all of or U portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner -Builder will have the building WORKERS'. COMPENSATION DECLARATION • I HEREBY AFFIRM UNDER PENALTY OF PERJURY one of the following declarations: have and will maintain a certificate of consent to self -insure for workers' , burden of proving that it was not built or ❑I compensation, issued by the Director of Industrial Relations as provided for by Section improved for the purpose of sale.)'• f ti 3700 of the Labor Code, for the performance of the work for which this permit is issued. Policy ,•. • No. I, as owner of the property, am exclusively contracting with licensed Contractors to . construct the project (Section 7044, Business and Professions Code: The Contractors' State I have and will maintain workers' compensation insurance, as required by Section 3700 of ❑0 License Law does not apply to an owner of property who builds or improves thereon, and who the Labor Code, for the performance of the work for which this permit is issued. My workers',; contracts for the projects with a licensed Contractor pursuant to the Contractors' State License compensation insurance carrier and policy number are: Law.). f - Cartier. FYFMPT Policy Number: Exp. Date:% - - I am exempt from licensure under the Contractors' State License Law for the following I certify that, in the performance of the work for which this permit is issued, I shall not reason: employ any person in any manner so as to become subject to the workers' Compensation laws of California, and agree that, if I should become subject to the workers' I ' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. - _ Owners Signature Date X PERMIT APPLICANT DECLARATION Signature Date By my signature below, I certify to each of the following: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS I am U a California licensed contractor or U the property owner' or U authorized to UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES act on the property owner's behalf**. t I have read this construction permit application and the information I have provided is AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN correct. ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN I agree to comply with all applicable city and county ordinances and state laws relating SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. to building construction. i I authorize representatives of this city or county to enter the above -identified property for inspection purposes. California Licensed Contractor, Property Owner' or Authorized Agent'': `requires separate verification form "requires separate CONSTRUCTION LENDING AGENCY DECLARATION - I hereby affirm under penalty of perjury that there is a construction lending agency for the authorization form performance of the work for which this permit is issued (Section 3097, Civil Code). - y r; s Lender's Name and Address X. lama of Permittee [SIGN] , Print Date , Lender's Name & Address ,City State zip ti FEE' INFORMATION Total Fees: $445.00 Fees Paid: $445.00 Balance Due: (None) Job Value: $6,500.00 .. t PROJECT DESCRIPTION: 16x330 CANADIAN SOLAR CS6U-330M ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES SYSTEM SIZE: 5.28 kW DC STC ARRAY AREA #1: 166.35 SQ. FT. ARRAY AREA #2: 166.35 SQ. FT. EQUIPMENT SUMMARY 16 CANADIAN SOLAR CS6U-330M 8 APS YC -500A MICROINVERTER SHEETINDEX PV -1 SITE PLAN PV -2 ROOF PLAN & MODULES PV -3 ELECTRICAL LINE DIAGRAM / PV -4 PLACARDS PV -5 ATTACHMENT DETAIL PV -6 to 9 EQUIPMENT SPECIFICATION 01 oR Qe- \ O� / lO EXISTING DRIVEWAY OOF #2 RAN OF 0`1 \ (E) MAIN SERVICE PANEL (B) CANADIAN SOLAR CSBU-330M / / _r Z m \ I I PROPER\ NF \ � I 1 SITE PLAN WITH ROOF PLAN \ PV -1 SCALE: 1/32" = 1'-O" 2 HOUSE PHOTO PV -1 SCALE: NTS Company Information: . M C ~ O _U M J 0) 0) (� C U) (5 Lp Y CV t J ��0� PROJECT NAME.& Russ Marks 1632 Garden Road, Durham, CA 95938, USA PHONE NO: 530-680-7331 APN NO:040-090-06� DATE: 5/10/2017 SHEET NAME SITE PLAN & 3 VICINITY MAP VICINITY MAP PV -1 SCALE: NTS SHEET NUMBER PV -1 I WEEBS GND I — — — --- — — — — —�- - -- -- -- — — — — _ PV MO[ ENGAGE CABLE WEEBS GND I i ELECTRICAL NOTES: 1. CONTRACTOR RESPONSIBLE FOR COMPLYING WITH ALL LOCAL &NEC CODE REQUIREMENTS AND MANUALS FOR INSTALL A PV SYSTEM. 2. ALL COMPONENTS MUST BE GROUNDED PER NEC REQUIREMENTS. - I 3. EACH MODULE MUST BE GROUNDED ACCORDING TO INSTALLATION REQUIREMENTS. 4. ALL EQUIPMENT SHALL BE LISTED PER NEC. 5. PER NEC 690.7, PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN OPEN POSITION. SIGN SHALL READ "WARNING SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINES AND LOAD SIDE MAY BE ENERGIZED IN OPEN POSITION OR EQUIVALENT". 6. PER NEC 705. O, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON THE PREMISES. 7. INTERCONNECTION METHOD SHALL COMPLY WITH NEC 690.64. ' I 8. A%C AND/OR D/C DISCONNECT MAY OR MAY NOT REQUIRED BY THE AHJ (AUTHORITY HAVING JURISDICTION). 9. WIRE SIZE ASSUMES THAT CONDUIT WILL BE RUN IN ATTIC SPACE OR LESS THAN 10' IS EXPOSED TO SUNLIGHT PER NEC 310.15(A)(2)Ex. WIRE I I GAUGE MAY NEED TO BE INCREASED IF RUN IN CONDUIT ON THE ROOF FOR MORE THAN 10' PER NEC 310.15(B)(3)(C). 10. DO NOT ATTACH ANY HARDWARE ON TOP OF RAIL DIRECTLY UNDER SOLAR MODULE. DOING SO MAY VOID MODULE WARRANTY. 11. INSTALL INVERTER PER MANUFACTURERS DIRECTIONS. JUNCTION BOX 600 V, NEMA 3 UL LISTED Lo I PV LOAD CENTER 240V, 125A/2P NEMA 3R, UL LISTED .(6) #10 AWG THWN-2 (2) #10 AWG THWN-2 GND IN %" PLASTIC L1 L2 J N G }- PLASTIC 10A/2P L1 L2 N J"PLASTIC G 10A/2P i------ —� L1 L2 G L — — — — N 1 ELECTRICAL LINE DIAGRAM PV -3 SCALE: NTS AC DISCONNECT: 240V, 60A/2P, FUSED 20A NEMA 3R, UL LISTED 20A i PuSTC L2 v L2 CDNDUIT N N r I— DG— (3) (3) #6 AWG THWN-2 (1) #10 AWG THWN-2 GND IN %4" PLASTIC SOLAR ARRAY (5.28 kW-DC,STC) TOTAL SOLAR ARRAY TOTAL (2.64 kW -DC STC) STRING OF (8) CANADIAN 330 SOLAR MODULES TOTAL 2.64 kW -DC STC & (4) APS YC -500 INVERTERS APS YC -500A MICROINVERTERS SOLAR ARRAY (5.28 kW -DC STC) TOTAL SOLAR ARRAY TOTAL (2.64 kW -DC STC) STRING OF (8) CANADIAN 330 SOLAR MODULES TOTAL 2.64 kW -DC STC & (4) APS YC -500 INVERTERS Company Information: DESIGN NOTES: ti 1 -PHASE, 240 V " TO COMPLY WITH [250.120(C)) r PROJECT NAME & ADDRESS IF EGC IS INSIDE CONDUIT OK TO USE #10, OR #8 co T\ IF EGC IS FREE AIR USE #6 BARE,Cu. • r APN NO:040-090-063 RAILS,MODULES & GROUND MOUNT STRUCTURE ARE IN CONTACT WITH EGC USING A UL 2703 GROUNDING Q HOUSE 240 V, 200A LAY -IN LUG SUCH AS "HELIOLUGU LUGPV LUG" COMDUITS ARE BONDED TO EGC USING GROUNDING PUSHING. I� O ARRAY GEC IS BARE,Cu. #6 V 0 ARRAY GROUNDING ELECTRODE IS 8' LONG k" MIN. PERPENDICULARLY DRIVEN (V) EGC COMPLIES WITH [690.43),[690.45] & [690.46) ' 0' (7) M c:CU V/ 0 N E cO . cn � J . cu (N =) W TO UTILITY GRID Q ~ BI-DIRECTIONAL o UTILITY. METER - 1 -PHASE, 240 V " PROJECT NAME & ADDRESS (E) MAIN SERVICE PANEL, 1 -PH, 3-W, 200A RATED, 240V, 2P Russ Marks 1632 Garden Road, _ Durham, CA 95938, USA T\ PG&E AND SMART METER PHONE NO: 530-680-7331 APN NO:040-090-063 (E) MAIN BREAKER TO HOUSE 240 V, 200A I LI LI I - I , I I EXISTING GROUNDING ELECTRODE SYSTEM (3) #6 AWG THWN-2 (1) #10 AWG THWN-2 GND IN %4" PLASTIC DATE: 5/10/2017 SHEET NAME ELECTRICAL LINE DIAGRAM SHEET NUMBER PV -3 MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES = 16 MODULES ' MODULE TYPE'= CANADIAN SOLAR CS6U-330M .. .MODULE WEIGHT = 49.4 LBS / 22.4 KG. MODULE DIMENSIONS = 772"x 39.1" = 20.96 SF UNIT WEIGHT OF ARRAY = 2.36 PSF ARRAY & ROOF AREA CALC'S (ROOF #1) ARRAY AREA = 166.35 SQ. FT. _ ROOF FACE AREA= 766.19 SQ. FT. 166.35/766.19 = 21.71 % OF ROOF FACE AREA COVERED BY ARRAY ARRAY R RC)OF ARFA (8) CANADIAN SOLAR CSOU-330M (E) UTILITY METER (E) MAIN SERVICE PANEL (N}AC DISCONNECT ---- (4) APB YC�A MICROINVERTER - 3/4" PLASTIC CONDUIT RUN FACE AREA CUVERED BY ARRAY ROOF DESCRIPTION ROOF TYPE - COMP f ROOF TILT.- 14' ROOF AZIMUTH - 135 300 f' , RAFTER SIZE - 2x6" @ 24" O.C. (E) BACKYARD 1 ROOF PLAN & MODULES PV -2: SCALE: 3/32" = 1'-0" Company Information: N DATE: 31. (E) FRONTYARD E 5/10/2017 3' JB s O ❑ -VENT, ATTIC FAN (ROOF OBSTRUCTION) (8) CANADIAN. iNV -INVERTER .0 - ROOF ATTACHMENT SOLAR C$8U-330M M.. _ De INTEGRATED DC DISCONNECT -RAFTERS ROOF PLAN & CANADIAN 04 SOLAR LOAD CENTER _____ MODULES SOLAR PM - PRODUCTION METER - CONDUIT SHEET NUMBER CS6U-330M MSP - MAIN SERVICE PANEL CB - COMBINER BOX PV -2 M (4) APB YC4300A MICROINVERTER p O U N M (N) SWH SOLAR MOUNT' 0 0') RACKING SYSTEM i (24) PV ATTACHMENT ®cu CO ch Z4" O.o: "0 V U)L_o oqpCU 0 W c.O,Q W PROJECT NAME & ADDRESS Russ Marks 1632 Garden Road, Durham, CA 95938, USA , PHONE NO: 530-680-7331 APN NO:040-090-063 DATE: LEGEND 5/10/2017 39.1" JB -JUNCTION BOX. O ❑ -VENT, ATTIC FAN (ROOF OBSTRUCTION) iNV -INVERTER .0 - ROOF ATTACHMENT SHEET NAME De INTEGRATED DC DISCONNECT -RAFTERS ROOF PLAN & CANADIAN 04 SOLAR LOAD CENTER _____ MODULES SOLAR PM - PRODUCTION METER - CONDUIT SHEET NUMBER CS6U-330M MSP - MAIN SERVICE PANEL CB - COMBINER BOX PV -2 r.s 3 ;�,s ° - <' ;'* y:�,t f„ t G .. `' ? '*.. .fit? 4'S''^"," ' rt. 1..;x•:"L. ",i. tF '.. x1i 'j 6 p fij: +. yr. ;,.• l 4t, f .� .1• - - � �;y .q � , `r» .•»ter v ... ,f�t,�',p " �_y. �:i� r^4> r+:--+-�— jq SOL�►RuWAREHOUSE Version 12.10.V2 - SWH Racking System Data Sheets t.•.. • .4 t \ '. { -F — i yY (MUS CONFORMS Intertek UL STD 2703 . � �'� ...'� ',{' �• � � Ste` ri ("r, Y � z y' � ��.�Y "AJ4''� f y :t k i 1 K K '{, 7•' �..,.: ;: �� �., ..+t ��.. +�•• � ry,.*.�w-,....r L -+ �- �.� � .�•Y'+c�.an. 9628.Valle Blud: Rosemead' CAr91770 Phoria 626-579=3288 � 1 info e5olarwarehouse.com' " @ .w ��•�a. ;a" .� y:'- r rd- :N'.y� �' .J f. �+ .:� s • *ff � ,rS. �. Y- f'. .� k �:f •.�. . .. ,��,' _;�.�. ;r'„i, w. , sy t .�, t ,ni`,'�ti � y . i 5w, t Version 12.10.v2^ �SV1%H,Racking System Data ta.Shee , , w; SOLAR WAREHOUSE SWH Solar Mount Rail , MFG -PN: MR -SW -SR -10.5, MR -SW -SR -12, MR -SW -SR -14, MR -SW -SR -14B, MR -SW -SR -17 SLOT FOR 1/4" T -BOLT OR HEX BOLT Rail material: 6063-T5 extruded aluminum alloy Q SLOT FOR Finish: Clear or black anodized " f 3/8" T -BOLT OR HEX BOLT 2.25" CONFORMS TO UL SUB 2703 e Y SLOT FOR OM � 3/8" T -BOLT OR HEX BOLT us Intertek .750"–�+—� 4009330 Properties Units Solar Mount Beam Height in 2.250 Approximate Weight plf• 0.700 Total Cross Sectional Area in' 0.588 Area Moment of Inertia X -Axis in' 0.299' Area Moment of Inertia Y -Axis in° 0.038' Tensile Strength MPa. 190.249' Yield Stregth MPa 165.732' Elongation (G.L.=25mm) �. % 17.2 " Hardness (HR15T) 71 't pdated 6/12/2012 ` Typical Composition Material °% SI % Fe % Cu % Mn % Mg % Zn % Ni % Cr % Pb % Sn % Ti % Al 6063 0.3972 0.2679 0.0469 0.0666 0.4936 0.0436 0.0056 0.0205 0.0010 0.0044 0.0188 98.6 Solar Warehouse" is a registered trademark and DBA of Calmonte Corporation. 9628 Valley Blvd .Rosemead; CA 91770 I Photie 626-519-3288. l info@esolarwarehouse.corT t Company Information: DATE: 5/10/2017 Y SHEET NAME EQUIPMENT SPECIFICATION SHEET NUMBER PV -8 _M O ~ _0 O. CU 00 _U J O O ' i.tY'Lo cc C . O) CO O U M �t Cn � CUo 0 IZ CU .L, cN :3 LU , CC� PROJECT NAME & ADDRESS Russ Marks 1632 Garden Road, Durham, CA 95938, USA PHONE NO: 530-680-7331 APN NO:040-090-063 DATE: 5/10/2017 Y SHEET NAME EQUIPMENT SPECIFICATION SHEET NUMBER PV -8 + 1. 1 F HOW 1 VASES wtrN Y T11101fiESS, i n �x I Part Name . . SWH'Rackirig System Dafa Sheet ver=ion12"10m2 SOLAR WAREHOUSE MR -SW -EC -35 SWH Solar Mount End Clamp End clamp material: 6005-T5 extruded aluminum alloy MFG -PN: MR -SW -EC -35, MR -SW -EC -356, Finish: Clear or black anodized MR -SW -EK -40, MR -SW -EK -40B, Bolt & nut material: 304 stainless steel and/or 316 stainless MR -SW -EF -45, MR -SW -EF -45B, steel ,. MR -SW -EE -SO, MR-SW-EESOB End clamp weight: Varies based on height: 0.052-0.06 lbs "K black end Gam Assemble end clamp•with one 1/4"-20 T -bolt and one 39-41 .056 "F" end clam 1/4"-20 ASTM F594 serrated flange nut: 44-46 ..058 "F" black end clam Use anti -seize and tighten to 10 ft -lbs of torque. Module ``_ `- .� ., "E" end clamp Modules must be installed at least 1'.5" from either end of a 49-51 .060 "E" black end clamp SWH solar mount rail. 49-51 t. CONFORMS TO UL SUB 2703 End Clamp .� Rail Vo • Intertek CU ' - offius Rail 41 `I 5 - M =' Intertek ? "3 CO 400.9330 1. 1 F HOW 1 VASES wtrN Y T11101fiESS, i n �x I Part Name . . Part Number ." Range of Heights (mm) Weight Ibs - 0 ( ) (without Hardware "C" end clam MR -SW -EC -35 34-36 .054 "C" black end clam MR -SW -EC -35B 34-36 .054 "Wend dam MR -SW -EK -40 39-41 1 .056 "K black end Gam MR -SW -EK -40B 39-41 .056 "F" end clam MR -SW -EF -45 44-46 ..058 "F" black end clam MR -SW -EF -45B 44-46 .058 "E" end clamp MR -SW -EE -50 49-51 .060 "E" black end clamp MR -SW -EE -50B 49-51 .060 Dimensions speahed in inches unless noted ; ?'f \'tiYY_`:'X` - '�` '%1' Yew n. �.�.-•t:-,;, ;w �.,'_�61r S?ff 1" 4:4 .. END.CLAMP IS CORRECTEND CLAMP IS ' TOO LONG TOO SHORT 7777-1 " 9628 Valley Blvd. Rosemead. CA 91770 I Phone 626-579'3288 I info@esolarwarehouse.eom Module n' t I" 01ST.v"CE t, eFsrrttn Noolnts !n l Y � I I , is Y 3. A— Dimensions specified ininchesbnless otherwise noted INCORRECT . . 9628 Valley Blvd Rosemead, CA 91770 -I Phone 626-579-3288 •) infoOesolarwarehouse com Company Information: 'version SWH Racking System, Data, Sheet1-2.10.v2 J SOLAR WAREHOUSE }�. �L-�.__r. - -`- t "' - .� `-- •----� SWH Solar Mount Mid Clamp MFG -PN: MR -SW -MC -20, MR -SW -MC -20B Mid clamp material: 6005-T5 extruded aluminum alloy Finish: Clear or black anodized • Bolt & nut material: 304 stainless steel and/or 316 stainless steel •.. Mid clamp weight: 0.058 lbs (without hardware) C) Assemble mid clamp with one 1/a"-20 T -bolt and one Y4"-20 ASTM �- ti F594 serrated flange nut O Use anti -seize and tighten to 10 ft-Ibs.of torque cu 00 CONFORMS TO UL SUB 2703 Mid Clamp, co (01 CO ,C Q tJs Rail Vo • Intertek CU ' 4009330 Module n' t I" 01ST.v"CE t, eFsrrttn Noolnts !n l Y � I I , is Y 3. A— Dimensions specified ininchesbnless otherwise noted INCORRECT . . 9628 Valley Blvd Rosemead, CA 91770 -I Phone 626-579-3288 •) infoOesolarwarehouse com Company Information: DATE: 5/10/2017 SHEET NAME W - EQUIPMENT SPECIFICATION ` SHEET NUMBER PV_9 r • C) ti O U cu 00 co LO C.M CO ,C Q M Vo • CU ' LP cu M =' J CO W -PROJECT NAME & ADDRESS Russ Marks r 1632 Garden Road, • Durham, CA 95938, USA ,PHONE NO: 530-680-7331 APN NO:040-090-063 DATE: 5/10/2017 SHEET NAME W - EQUIPMENT SPECIFICATION ` SHEET NUMBER PV_9 SEE (2/F FOR ENLARi V 1 ATTACHMENT DETAIL PV -6 SCALE: 1" = V-0" PV MODULE FLASHING, 12"x12"x0.050", 5050; MILL 2 ATTACHMENT DETAIL (enlarged -view) PVA SCALE: NTS Company Information: (D 0:3 Uj (DoUj GROUNDING END/MID CLAMP - SWH RACKING PROJECT NAME & ADDRESS ALUMN, "L" BRACKET W/3/8" SS Russ Marks BOLT & NUT 1632 Garden Road, Durham, CA 95938, USA E COMPOSITE PHONE NO: 530-680-7331 APN NO:040-090-063 SHINGLE ROOF 5/16"x3" SS LAG BOLT WITH MIN 2%2" THREAD EMBEDMENT, SEALED PENETRATION 2"x6" RAFTERS @ 24" OC DATE: 5/10/2017 SHEET NAME ATTACHMENT DETAIL SHEET NUMBER PV -5 ti c. co O ti - o N Co V _U .0 J C N M V)�Uo L E V/ '^ N -r— (D 0:3 Uj (DoUj GROUNDING END/MID CLAMP - SWH RACKING PROJECT NAME & ADDRESS ALUMN, "L" BRACKET W/3/8" SS Russ Marks BOLT & NUT 1632 Garden Road, Durham, CA 95938, USA E COMPOSITE PHONE NO: 530-680-7331 APN NO:040-090-063 SHINGLE ROOF 5/16"x3" SS LAG BOLT WITH MIN 2%2" THREAD EMBEDMENT, SEALED PENETRATION 2"x6" RAFTERS @ 24" OC DATE: 5/10/2017 SHEET NAME ATTACHMENT DETAIL SHEET NUMBER PV -5 s� APSystem's'' Q A L T E N E R G Y P O W E R Leading the Industry in • Solar Microinverter Technology `i xr' wt•r 4 IN z ; � Single unit connects two solar rnodules „ Maximum output power 500W ' Individual MPPT for each,module' ' • Rated upto310W 14• . Up to 14 solar modules (7x YC500s) in.as' +• "' string with a 20A breaker DIMENSIONS 88.S•'(2250mm) Our flagship product, the APsystems YC500A is a grid -tied 8.T• 22tmmi - microinverter with intelligent networking and monitoring a a systems to ensure maximum efficiency. Highly dependable ® o and cost effective, the YC500A handles up to 31OW es -0 7ma,) )' modules with negligible clipping, delivering 25OW AC per 8 } module with dual MPPT. Half the inverters and half the 1{ installation means real cost savings for residential and commercial customers. APsystems kYC500A Microinverter �eet INPUT DATA (DC) Recommended PV Module Power Range (STC) �y180-310W • MPPT Voltage Range RR 22-45V .--- Maximum Input Voltage =1 SSV y Maximum Input Current i 12A X 2 OUTPUT DATA (AC)' i w. Rated•OutputP-7­7:::=+C50717 + SOOW • Maximum Output Current 2.08A @ 240V 2.4A @208V Nominal Output Voltage/Range — 240V-' .�r —� 240V/211V-264V' w I' Nominal Output Voltage/Range - 208V 208V/183V-229V• Nominal Output Frequency/Range. •�_ �-�_ `. 60Hz/ 59.3-60.51-1z• . Power Factor >0.99 Total Harmonic Distortion ; +., •. r 3% • Maximum Units Per Branch i 7 per 20A @ 240V 6 per 20A @ 208V , . EFFICIENCY Peak Efficiency. : ,: • � r3 95,5_% `� r CEC Weighted Efficiency ' 95% V;. Nominal MPP Tracking Efficiency' U + t • 99.5% MECHANICAL DATA Storage Temperature Range„ ' • "# _ 40'F,Yo +185°F (-40'C to +85'C) Operating Temperature Range -40°F to +149°F (-40°C 1:6+65-C) 'Dimensions (WxHxD) inches',�r ' . _, •> t -;' 875':,x 65':,x 1.1":7 _ g 5 - Dimensions (WxHxD) mm 221mm x 167mm x 29mm -77— -- Enclosure Rating NEMA 6 _Cooling ! _ : ° _. . ",, . r Natural Convectio�No FanF FEATURES & COMPLIANCE -' Communication I Power line (PLC) Warcanty; lO years standard extendable to_25 years Emissions & Immunity (EMC)'Compliance i. FCC PART 15, ANSI C63.4 2003, ICES -003 Safety Class Compliances ��;� s' . s UL 1741 , C9A C22.2, No107.1-91, NEC2014 690.12 — �� ��_�_�90w Grid Connection Compliance i IEEE 1547 r, t Specifications subject to change without notice - please ensure you are using the , I Programmable per customer and utility requirements. most recent update found at www.APsystems.com All settings UL approved • "CEC registered as Altenergy Power System Inc. 12.7.15 D All Rig;ts Reserved - 600 Ericksen Ave NE, Suite 200, Seattle, WA 98110 -I 844.666.7035 I APsystems.com APsyste m5 s_ - -• O ALTEN E RGY POWER Company Information: ' ' i DATE: 5/10/2017 SHEET NAME EQUIPMENT SPECIFICATION SHEET NUMBER PV. -7 r O O . U N M J U (o C M p -0Q W' " U o i r(D E .LP 04 s J cu M G PROJECT NAME & ADDRESS Russ Marks 1632 Garden Road, Durham, CA 95938, USA - PHONE NO: 530-680-7331 APN NO:040-090-063 i DATE: 5/10/2017 SHEET NAME EQUIPMENT SPECIFICATION SHEET NUMBER PV. -7 • RATED AC -OPERATING CURRENT 40 AMPS A NOMINAL OPERATING a 40 VOLTS' LABEL LOCATION:: - A AC DISCONNECT, POINT OF INTERCONNECTION LABEL LOCATION: (PER CODE: NEC690.54) DC DISCONNECT, INVERTER (PER CODE: NEC 690.35(F)) WARNING [To be used when inverter is ungrounded]INVERTER OUTPUT CONNECTION DO NOT - t RELOCATE THIS OVERCURRENT DEVICE ' LABEL LOCATION: • r V T'ELECTRIC SHOCK HAZARD' POINT OF INTERCONNECTION THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED (PER CODE: NEC 705.12(D)(7)) [Not required if panelboard is rated not less than sum of ampere ratings AND MAY BE ENERGIZED - of all overcurrent devices supplying it] co LABEL LOCATION: CAUTION: SOLAR t r DC DISCONNECT, INVERTER (PER CODE: NEC 690.35(F)) o LABEL LOCATION: Q [To be used when inverter is ungrounded] .'' MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES, • r 00 � L) (a.. AND CABLE ASSEMBLIES AT LEAST EVERY 10 FT, AT TURNS AND ABOVE/BELOW PENETRATIONS _ M • ' J'ry ANDALL COMBINER/JUCTION BOXES., (PER CODE: IFC605.11.1.4) + - ' _ NL LO ELECTRIC SHOCK HAZARD - • _ Q"M DO NOT TOUCH TERMINALS SOLAR DISCONNECT _ r r < �O� U �j TERMINALS ON BOTH LINE AND i LOAD SIDES MAY BE ENERGIZED • ' LABEL LOCATION: t _ ', :, M (O IN THE OPEN POSITION. DISCONNECT, POINT OF INTERCONNECTION _ 1,s r:: ti - Cn 0' MLo, ` t - (PER CODE: NEC690.13(B)) i y , DC VOLTAGE IS ALWAYS PRESENT - , ; LU WHEN SOLAR MODULES ARE - l ac _ t d' s x iO � J EXPOSED TO SUNLIGHT • • • �/1 0 011ie LABEL LOCATION: _ , -, - , r1 y ?F • _ AC DISCONNECT, POINTOF INTERCONNECTION'.,LABEL LOCATION. (PER CODE: NEC 690.17(E)) POINT•OF INTERCONNECTION 'g y r. - ' ` N • ti i' K' .4 _ (PER CODE: CEC 705.12(D)(4)) `t - y • a. D RJ e = . • • PROJECT NAME & AD RESS ELECTRIC'SHOCK HAZARD 5�" ` r SYSTEM CONNECTED` F• f •' a ` DO NOT TOUCH TERMINALS ' t. LABEL LOCATION: - • . .,�, - - -Russ Marks ` TERMINALS ON BOTH LINE AND POINT OF INTERCONNECTION . r, • • 1632 Garden Road, (PER CODE: CEC690.15, 690.13(6)). x ' , - _ - + - Durham, CA 95938; USA _.LOAD SIDES MAY.BE ENERGIZED IN THE OPEN POSITIONIL _ _ _ 1. • h PHONE NO: 530680 7331 APN N0:040-090-063 . LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION PER CODE: NEC 690.17(E), CB • • - �. _ „ s . - t �LNo user serviceable parts inside ct authorized service provider for assistance LABEL LOCATION: INVERTER, JUNCTION BOXES (ROOF), DISCONNECT (PER CODE: NEC690.13.G.3 & NEC 690.13.G.4) POWERWARNING: PHOTOVOLTAIC ' DATE: LABEL LOCATION: _ • , CONDUIT, COMBINER BOX 5/10/201.7. (PER CODE: NEC690.31(G)(3)(4) & NEC 690.13(G)(4) • - F ` ' SHEET NAME ADHESIVE FASTENED SIGNS: - r THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT PLACARDS WHERE IT IS INSTALLED. �. WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD ' • • �, - APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD v • - COMPLY WITH ANSI Z535.41NEC 110.21(B) FIELD MARKING]. ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF SHEET NUMBER PROPERLY ADHERED. -VINYL SIGNS SHALL BE WEATHER • - - RESISTANT [IFC 605.11.1.31 _ PV -4 Company Information: