Loading...
HomeMy WebLinkAboutB17-1297 047-750-090BUTTE COUNTY.- a AREA ' DEPARTMENT OF DEVELOPMENT SERVICES INSPECTION CARD :MUST BE ON JOB SITE � 4` 's • r: ; 24 Hour, inspection Line (IVR) : 530.538.4365 (Cut off time for inspections is 3prn) Development Services cannot guarantee inspections on the date requested } " DEVELOFMENi SE0.VICE5 •:.' Office: 530.538.7601 Fax: 531 Permit No: B17-1297` • Issued'; 6/28/2017 APN:- 047.-.750=090 Address: _. 13953 POMEGRANATE CT; CHICO Owner::.'.' : Eduardo Alvarado.. Permit Type: ° SOLAR ROOF -RES Description: Solar PV Installation .538.7785 www.ButteCounty.neUdds Flood Zone: None SRA Area: No'SETBACKS for Zoning. AG. SRA ­PW t - s Front: Centerline of Road:'. Rear.. SRA: �. Street: AG: Interior - Total Setback from Centerline of Road: ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING. Inspection IType IVR' INSP DATE Setbacks 131. Foundations / Footings 111. _ Pier/Column Footings , .',' "' 122'' Eufer Ground " 216 Masonry Grout ` 120 .Setbacks 131 Do Not Pour Concrete Until Above are Sign d Pre -Slab 124. Gas Test Underground/floor 404 Gas Piping Underground/floor 403 , Underfloor Framing ,' 149 Underfloor. Ducts 319, Shear Transfer -136 Under Floor Plumbing 412 Under Slab Plumbing °. 411 Blocking/Underpin in 612 Tiedown/Soft Set System 61 l Do Not Install Floor,Shciathing or Slab Until Above Signe d Shearwall/B.W.P.-Interior: -134 ShearwallB.W.P.'-Exterior, -;" 135 Roof Nail/Drag Trusses _ 129, Manometer Test 605 Do Not Install Siding/Stucco o Roofing Until Above Signed Rough Framing 153 Rough Plumbing 406, " Rough Mechanical' 316 Rough'Electrical 208, 4 -Way Rough Framing. ' 128 ' Gas Piping House 403 Gas Test House 404 Shower,Pan/Tub Test,,. 408', 2 Do Not Insulate Until Above Signed Permit Final 802 Electrical Final ^ . 803 Mechanical Final _809 Plumbing Final Fire Sprinkler Test or -Final • 702 Swimming Pools` Inspection Type IVR INSP DATE T -Bar Ceiling 145 F Stucco Lath 142' Swimming Pools` .Setbacks 131 Pool Plumbing Test 504- ._ Gas Test Pre-Gunite 506 Pre -Deck 505 Pool Fencing/AlarmsBarriers 503 . Pre -Plaster 507 Manufactured Homes Setbacks 131 " Blocking/Underpin in 612 Tiedown/Soft Set System 61 l Permanent Foundation System 613 Underground Electric 218 Sewer 407 Underground Water 417. . Manometer Test 605 Continuity Test 602 Skirtin /Ste s/Landings 610 Coach Info Manufactures Name: Date of Manufacture: . Model Name/Number: Serial Numbers: Length x Width: Insignia: Public Works Final 538.7681 Fire De artment/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final f- 'PROJECT FINAL 6 .( p, L, " *Project Final is a Certificate of Occupancy for (Residential Only) PERMITS BECOME NULLA Nb VOID 1 YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS CONIMENCED, YOU MAY'PAY FOR A I YEAR. , RENEWAL 30 DAI'S PRIOR TO EXPIRATION October 30, 2014 UniRac 1411 Broadway Boulevard NE Albuquerque, New Mexico 87102-1545 TEL: (505) 242-6411 FAX: (505) 242-6412 ; Attn.: Engineering Department, STRUCTURAL ENGINEERS QOFESS/0/ ENNEi CO N j� ���• FP c2 CD m No. S3878 * Exp. 3-31- sT9TF OF F Re: Engineering Certification for UniRac's SolarMount Design & Engineering Guide PZSE, Inc. -Structural Engineers has reviewed UniRac's "SolarMount Design & Engineering Guide" and specifically the enhancements of the SolarMount Flush -to -Roof System, Pressure Lookup Tables, and Downward & Upward Span Length Tables. This certification excludes connections to building structures and the effects on building structure components. All information, data and analysis contained within the Installation Manual are based on, and comply with the. following: 1. 2012 International Building Code, by International Code Council, Inc., 2012 2. 2013 California Building Code, by California Building Standards Commission, 2013 3. ASCE/SEI 7-10 Minimum Design Loads for Buildings and other Structures 4. 2010 Aluminum Design Manual, by The Aluminum Association, 2010. This letter certifies that the structural calculations contained within UniRac's "SolarMount Design & Engineering Guide" are in compliance with the above Codes. If you have any questions on the above, do not hesitate to call. Sincerely, Paul Zacher, SE President 8150 Sierra College Boulevard, Suite 150 • Roseville, CA 95661 • 916.961.3960 P •. 916.961.3965 0 www.pzse.com E -Mount Lag I QMSF"­"` AG � 9.00� REM NO. DESCRIPTION QTY./BOXI 1 FLASHING, 9" X 17' X .040", 5052, MILL l 2 QBLOCK, CLASSIC, A360.1 CAST AL, MILL 1 3 PLUG, SEALING, 5/16" X 7/8", EPDM / 18-8 SS 1 4 LAG SCREW, HEX HEAD, 5/16" x 5-1 /7', 18$ SS 1 5 WASHER. FENDER, 5/16" ID X 1-1 /4" OD, 18-8 SS 1 - RACKING COMPONENTS NOT INCLUDED 5 a 4 2 1 Lag pull-out (withdrawal) capacities (lbs) in typical lumber: Lag Bolt Specifications Specific Gravity 5/16' shaft per 3" thread depth 5/16" shaft per 1' thread depth 1.29 Quick Mount PV: 266 Douglas Fir, South .46 - 705 235 Engelmann Spruce, Lodgepole Pine (MSR 1650 f & higher) TITLE: 235 Hem, Fir QMSE-LAG: QMPV E -MOUNT 212 AVAILABLE IN MILL, AND WITH LAG BOLT 235 BRONZE ANODIZED FINISHES .55 921 ` Spruce, Pine, Fir UNLESS OTHERWISE SPECIFIED: I SIZE I DRP.WN BY: RAD REV 266 DMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL= I /8 A DAiE: 3/2/2015 3 IME rLoawTpx coraAr+Fnr.nm ORAVAGlSMESpEPRoicarroFaucr A,OIM w. ANYMWMCWq WPA DRAM DO NOTSCALEDRAWNG 0PUCE DECWAL l.18 A wHWewmgmn�F wemF�+`tv.,6tgNaa•a.�oumw6Pro�en[u. THREE PUCE DECIMAL 2. 2S SCAIEI:3 WEIGHT:0.96 I SHEET OF . a 4 2 1 Lag pull-out (withdrawal) capacities (lbs) in typical lumber: Lag Bolt Specifications Specific Gravity 5/16' shaft per 3" thread depth 5/16" shaft per 1' thread depth Douglas Fir, Larch .50 798 266 Douglas Fir, South .46 - 705 235 Engelmann Spruce, Lodgepole Pine (MSR 1650 f & higher) .46 705 235 Hem, Fir .43 636 212 Hem, Fir (North) .46 705 235 Southern Pine .55 921 307 Spruce, Pine, Fir A2 615 205 Spruce, Pine, Fir (E of 2 million psi and higher grades of MSR and MEL) .50 798 266 Sources: American Wood Council, NDS 2005, Table 11.2 A, 11.3,2 A Notes: 1) Thread must be embedded Ina rafter or other structural roof member. 2) See NDS Table 11.5.1C for required edge distances. quick Mount PV° RESPECT THE ROOF BI 7.2.3-31 Mar -2015, Rev 3 tv,�: icy � ♦ Doi SOLARMouw Technical Datashee��: UNI A HILTI GROUP COWANY' ` SolarMount Technical Datasheet Pub 110818 -ltd V1.0 August 2011 ' •-�SolarMount Module Connection Hardware...........................{...................................... 1 F Bottom Up Module Clip...........'................................................................... MidClamp ...... :......... : ...... ..:................................................................. .2 EndClamp ............. I....................................................................................................... 2 ' SolarMount Beam Connection Hardware......................................................................3 L -Foot ..... '................ ............................. 3 SolarMount Beams...........'......:... ...........................4 SolarMount Module' Connection Hardware, SolarMount Bottom Up Module Clip ' .• Part No. 302000C ` Washer Bottom Up Clip material: One of the following extruded aluminum Bottom. F ut (hidden .se alloys: 6005-T5, 6105-T5, 6061-T6 Up Clip <x no N'. Ultimate tensile: 38ksi, Yield: 35 ksi k Finish: Clear Anodized Bottom Up Clip weight: —0.031 lbs (14g) "� �a'� - �w Bolt Allowable and design loads are valid when components are . Beam { ,_;=� > .` assembled with SolarMount series beams according to authorized UNIRAC documents .N . Assemble with one'/<" -20 ASTM F593 bolt, one'/4'-20 ASTM F594 W,:. .; serrated flange nut, and one /4' flat washer �, r-• * Use anti -seize and tighten to 10 ft -lbs of torque c� Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third party test results from an IAS accredited laboratory • Module edge must be fully supported by the beam ` * NOTE ON WASHER: Install washer on bolt head side of assembly. DO NOT install washer under serrated flange nut Applied Load Direction Average Ultimate lbs (N) Allowable Load lbs (N) Safety Factor, FS Design Load lbs (N) Resistance Factor, ' 4) Tension, Y+ 1566 (6967) 686 (3052) 2.28 1038 (4615) 0.662 Transverse, X± 1128 (5019) 329 (1463) 3.43 497 (2213), 0.441 Sliding, Z± 66 (292) 1 27 (119) 1 2.44 41 (181) 0.619 Dimensions specified in inches unless noted • � F t • • • •1` . tl- . J. r. - 4 t SolarMount Mid Clamp PartNo. 302101C, 302101D, 302103C, 302104D, 302105D,302106D ` 1.00 OLSTX#M .I_ _ ►n_! Y A l LrX Dimensions specified in inches unless noted SolarMount End Clamp PartNo.302001C,302002C,302002D,302003C, 302003D,302004C,302004D,302005C,302005D, 302006C,302006D,302007D,302008C,302008D, 302009C;302009D,302010C,302011C,302012C � wr : .UNI'RIAC •• ' A' HI&6ROUPT6MPANi • Mid clamp material: One of the following extruded aluminum alloys: 6005-T5, 6105-T5, 6061-T6 • Ultimate tensile: 38ksi, Yield: 35 ksi • Finish: Clear or Dark Anodized • Mid clamp weight: 0.050 lbs (23g) • Allowable and design loads are valid when components are assembled according to authorized UNIRAC documents • Values represent the allowable and design load capacity of a single mid clamp assembly when used with a SolarMount series beam to retain a module in the direction indicated • Assemble mid clamp with one Unirac W-20 T -bolt and one Y4'-20 ASTM F594 serrated flange nut • Use anti -seize and tighten to 10 ft -lbs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third - party test results from an IAS accredited laboratory Applied Load Direction Average Ultimate lbs (N) Allowable Load lbs (N) Safety Factor, FS Design Load lbs (N) Resistance Factor, m Tension, Y+ 2020 (8987) 891 (3963) 2.27 1348 (5994) 0.667 Transverse, Z± 520 (2313) 229 (1017) 2.27 1 346 (1539) 0.665 Sliding, X± 1194 (5312) 490 (2179) 2.44 741 (3295) 0.620 � • . 1.9 . �'a+r vw[s . wrt" MOM • TM[OO w Dimensions specify • End clamp material: One of the following extruded aluminum alloys: 6005-T5, 6105-T5, 6061-T6 • • Ultimate tensile: 38ksi, Yield: 35 ksi • Finish: Clear or Dark Anodized • End clamp weight: varies based on height: -0.058 lbs (26g) Allowable and design loads are valid when components are assembled according to authorized UNIRAC documents • Values represent the allowable and design load capacity of a single end clamp assembly when used with a SolarMount series beam to retain a module in the direction indicated • Assemble with one Unirac'/4"-20 T -bolt and one'/4"-20 ASTM F594 serrated flange nut • Use anti -seize and tighten to 10 ft -lbs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third - party test results from an IAS accredited laboratory • Modules must be installed at least 1.5 in from either end of a, beam Applied Load Direction Average Ultimate lbs (N) Allowable Load lbs (N) Safety Factor, FS Design Loads lbs (N) Resistance Factor, m Tension, Y+ 1321 (5876) U9(2352) 2.50 800 (3557) 0.605 Transverse, Z± 63 (279) 14 (61) 4.58 21 (92) 0.330 Sliding, X± 142 (630) 1 52 (231) 2.72 79 (349) 0.555 p ::=UNIRAC, A HILTI GROUP COMPANY' SolarMount Beam Connection Hardware SolarMount L -Foot Allowable Load lbs (N) Part No. 304000C, 30400013 Design Load Ibs (N) Resistance Factor, m • L -Foot material: One of the following extruded aliminum alloys: 6005- -. T5, 6105-T5, 6061-T6 tiY ,moi"' Ultimate tensile: 38ksi, Yield: 35 ksi '-- Finish: Clear or Dark Anodized r _ . L -Foot weight: varies based on height: —0.215 lbs (98g) 2.63 Allowable and design loads are valid when components are Bea assembled with SolarMount series beams accordling to authorized _�t Bolt UNIRAC documents L -Foot For the beam to L -Foot connection:' 0.615 • Assemble with one ASTM F593 %;1.16 hex head screw and one errated ASTM F594'/e'serrated flange nut ' hange:Nu • Use anti -seize and tighten to 30 ft -lbs of torque 0.664 Resistance factors and safety factors are determ ned according to part 1 section 9 of the 2005 Aluminum Design Manua and third -party test. Y results from an IAS accredited laboratory ' 4 0-X NOTE: Loads are given for the L -Foot to beam connection only; be sure to check load limits for standoff, lag screw, or other attachment method 3•n 3X SLOT FOR. Dimensions specified in inches unless noted Applied Load Direction Average Ultimate lbs (N) Allowable Load lbs (N) 'Safety Factor, FS Design Load Ibs (N) Resistance Factor, m Sliding, Z± 1766 (7856) 755 (3356) 2.34 1141 (5077) 0.646 Tension, Y+ 1859 (8269) 707 (3144) 2.63 106-3(4755) 0.575 Compression, Y- 3258 (14492) 1 1325(5893)1 2.461 200.1(8913) 0.615 Traverse, X± 1 486 (2162) 213(949)1 2.28 323 (1436) 0.664 i SOLARMouw Technical D, t UNIRAC - • A HILTI'GROUP COMPANY SolarMount Beams tr Part No. 310132C, 310132C -B, 310168C, 310168C -B, 310168D 310208C,310208C-B,310240C,310240C-B,310240D, 410144M, 410168M, 410204M, 410240M r• Properties Units SolarMount SolarMount HD Beam Height in 2.5 ;' 3.0 Approximate Weight (per linear ft) plf 0.8111.271 Total Cross Sectional Area int 0.676 1.059 Section Modulus (X=Axis) in 0.353 0.898 Section Modulus (Y -Axis) in 0.113 • 0.221 Moment of Inertia (X -Axis) in" 0.464 1.450 ' Moment of Inertia (Y -Axis) in" 0.044 0.267 Radius of Gyration (X -Axis) in 0.289 1.170 - Radius of Gyration (Y -Axis) in 0.254 0.502- p SLOT FOR T -BOLT OR 1.728 SLOT FOR T-BOLf/' 4",HEX HEAD SCREW !/4" HEX HEAD SC 2X SLOT FOR SLOT FOR BOTTOM CLIP 2.500 BOTTOM CLIP T i, 3.000 ..' 1.3116 rl y SLOT FOR ' 3Y8" HEX BOLT OLr SLOT FOR 1.385 -r i 3�" HEX BOLT � = .387- 750 1. Y y1.875 L#X►X w , SolarMount Beam SolarMount HD Beam Dimensions specified in inches unless noted �• '0+ ENGINEERING DRAWING (mm) Rear View Frame Cross Section A -A 0 v Mounting Hole ELECTRICAL DATA I STC* All -Black CS6K 270M 275M 280M Nominal Max. Power (Pmax) 270 W 275 W 280 W Opt. Operating Voltage (Vmp) 31.1 V 31.3 V 31.5 V Opt. Operating Current (Imp) 8.67 A 8.80 A 8.89 A Open Circuit Voltage (Voc) 38.2 V 38.3 V 38.5 V Short Circuit Current (Isc) 9.19 A 9.31 A 9.43 A Module Efficiency 16.50% 16.80% 17.11% Operating Temperature -40*C - +85*C Max. System Voltage 1000 V (IEC) or 1000 V (UL) Module Fire Performance TYPE 1 (UL 1703) or CLASS C (IEC 61730) Max. Series Fuse Rating 15A Application Classification Class A Power Tolerance 0-5W *Under Standard Test Conditions (STC) of irradiance of 1000W/W, spectrum AM 1.5 and cell temperature of 25-C. ELECTRICAL DATA 1. NMOT* All -Black CS6K 285M 290M 295M Nominal Max. Power (Pmax) 197 W 201 W 205 W Opt. Operating Voltage (Vmp) 28.5 V 28.7 V 28.9 V Opt. Operating Current (Imp) 6.93 A 7.02 A 7.10 A Open Circuit Voltage (Voc) 35.5 V 35.5 V 35.7 V Short Circuit Current (Isc) 7.43 A 7.52 A 7.62 A * Under Nominal Module Operating Temperature (NMOT), irradiance of 800 W/ ml, spectrum AM 1.5, ambient temperature 20-C, wind speed 1 m/s. PERFORMANCE AT LOW IRRADIANCE Outstanding performance at low irradiance,, with an average relative efficiency of 96.5 % from irradiances, between 200 W/m2 and 1000 W/m2 (AM 1.5, 25°C). The aforesaid datasheet only provides the general information on Canadian Solar products and, due to the on-going innovation and improvement, please always contact your local Canadian Solar sales representative for the updated information on specifications, key features and certifcation requirements of Canadian Solar products in your region. Please be kindly advised that PV modules should be handled and installed by qualified people who have professional skills and please carefully read the safety and installation instructions before using our PV modules. ALL -BLACK CS6K-280M / I-V CURVES A A 5 10 15 20 25 30 35 40 N 1000 W/m' 800 W/m' 600 W/W 400 W/m' MECHANICAL DATA Specification Data 5 10 15 20 25 30 35 40 " 5-C 25-C 45-C ■ 65-C Cell Type Mono -crystalline, 6 inch Cell Arrangement 60 (6 x 10) Dimensions 1650x992x4O mm (65.0x39.1x1.57 in) Weight 18.2 kg (40.1 lbs) Front Cover 3.2 mm tempered glass Frame Material Anodized aluminium alloy J -Box IP67, 3 diodes Cable 4 mm2 (IEC) or4 mm2 & 12 AVS/G 1000 V (UL), 1000 mm (39.4 in) Connectors T4 series or PV2 series Per Pallet 26 pieces, 520 kg (1146.4 lbs) Per Container (40' HQ) 728 pieces TEMPERATURE CHARACTERISTICS Specification Data Temperature Coefficient (Pmax) -0.41 % /°C Temperature Coefficient (Voc) -0.31 % /*C Temperature Coefficient (Isc) 0.053 % /*C Nominal Module Operating Temperature (NMOT) 44±2 °C PARTNER SECTION CANADIAN SOLAR INC. May 2017. All rights reserved, PV Module Product Datasheet V5.54 -EN 1 I , t t�,�r CanadianSolar - CS6 K-270] 2751280 M r 4 t Canadian Solar's ALL -BLACK CS6K-M modules are. { equipped with dark mono -crystalline cells, a dark colored backsheet and a black frame for enhanced •. I , t ALL -BLACK - CS6 K-270] 2751280 M r t Canadian Solar's ALL -BLACK CS6K-M modules are. { equipped with dark mono -crystalline cells, a dark colored backsheet and a black frame for enhanced •. ' aesthetics and reliable output. This product can improve tsy r 4t the aesthetics of a rooftop. { KEY FEATURES ; 25 linear ower output warren p years p warranty, r 4 I+' Excellent•module efficiencyof x ti F • upto'17.11% product warranty on materials`,,._'.• �'. �'� °' �' • < • _ years and workmanship r ? _ Outstanding low irradiance _ • t,. t' r performance of up to 96.5% ................................................................................. ........................... ...........:... :.....`...;e' lISO MANAGEMENT SYSTEM CERTIFICATES* •;, ,� " ' 9001:2008 / Quality management system 4 . .' IP67 junction box for long-term ` I50 14001:2004 /Standards for environmental management system • iP67 weather. endurance - OHSAS 180012007 /International standards for occupational. health and safety., _ Heavy snow load up to 6000 Pa, * PRODUCT CERTIFICATES '' "} • 0 0 Wind load Up t0 4000 Pd * IEC 61215 / IEC 61730: VDE / CE / MCS / CEC AU UL 1703 / IEC 61215 performance: CEC listed (US) UL 1703: CSA Take -e -way _ � .;• •, ' • .{ •',gip •BBA✓ �V i (y/\� A-CERTs co-usMCS M • - \ .1 Please contact your local Canadian Solar sales representative for the specific product ,'•• w . •- certificates applicable in your market. , ..................................... is committed to providing high quality CANADIAN SOLAR INC.N , • ' solar products, solar system solutions and services to'customers around the world. As a leading PV project developer and ^ manufacturer of solar modules with over 20 GW deployed around the world since 2001, Canadian Solar Inc. (NASDAQ: CSIQ) is one of ^ • the most bankable solar companies worldwide. w _ . *For detail information, please refer to Installation Manual. ....................................... ....... ................ ............ ....... ........... ............ ............ ... ... '{ ........ - t. CANADIAN SOLAR INC. ' " 545 Speedvale Avenue West, Guelph, Ontario N1 K 1 E6, Canada, www.canadiansolar.com, support@canadian'solar:corrn • ) R -4 i. 4 L7rimi h � ', .,USA,- G- ITALY, -,FRANCE - GERMANY -ITALY NETHERLANDS -.UK -ISRAEL www.soiareage-.0 S, 'q solar=@@Single Phase Inverters for North America SE3000A-US/SE380OA-USIfSE5000A-US/SE6000A-US/ SE760OA-US / SE1000OA-US / SE1140OA-US SE3000A-US SE380OA-US I SESOOOA-US I SE6000A-US I SE760OA-US I SESOOOOA- US I SE1140OA-US S OUTPUT Nominal AC Power Output ' 3000 Max. AC Power Output 3300 ....................................................... AC Output Voltage Min. -Nom. -Max -PI 3/4" minimum / 1-2 strings / 16-6 AWG 183 - 208 229 Vac ........................... .......✓.. 4 AC Output Voltage Min: Nom.-Max!t1 4050 211-240-264 Vac 6750 ...................................................... AC Frequency Min. -Nom. -Max!') 13500 Max. Continuous Output Current 12.5 ........................................... GFDI Threshold .. ..................................................... . Utility Monitoring, Isianding Protection, Country I 3800 5000 6000 7600 .11400 5400 @ 208V 10800 @ 208V ........ ........................ . . . . ..... ................ .10000,�a 240V 4150 6000 8350 r 12000 � � Baso@Zaoy.. , io9so,@2aov............. 10 .................................................. ................ ....................................I.... ✓ .1 v/ .1✓ ✓ .................................................. ................ ............................... 59.3-60-................ I......16......I.. 21 Gln 240V...I.......25....... ....... I...42 �al 240V...I...... 47.5.. 1 ....................................................................................................... ifigurable Thresholds Yes ) INPUT RS485, RS232, Ethernet, 2igBee (optional) .......................................................................................................................... ........... ! Revenue Grade Data, ANSI C12.1 ............................................................................................................................................................................. OptionalI 3/4" minimum / 1-2 strings / 16-6 AWG t Rapid Shutdown — NEC 2014 690.12 ) Z' MaximRrnKNwer(STC) ........................................................................................................... 4050 5100 6750 8100 10250 13500 15350 W Transformer -less, Un rounded ..........................................................Yes ..........775 x 315 x 260 ................................. INSTALLATION SPECIFICATIONS ) ................ ............................................... ............8.8.-41.404 ............. Ib /.kp... Max. Input Voltage, Natural 500 convection Vdc Nom. DC input Volta&e ......... Natural Convection and internal Fans (user replaceable) 325 @ 208V 1350 @ 240V Vdc :. Max. Input Curre.... --.23...... I..30 ..........9.5......I......13......I. i5:5.@.240V..I...... 18......I*, 5@2o480VV..l.......34.5..........Adc.... Max. Input Short Circuit Current45 ................................................................................................................................................................................ Adc Reverse -Polarity Protection Yes Ground -Fault Isolation Detection ........................................................................ 600ka Sensitivity ......... ................ ............................................... Maximum Inverter Efficiency s 97:7 98.2 98.3 98.3 98 98 98 % CEC Weighted Efficiency 97.5 98 I... 97.5 97.5 I................ 97.5 % ........................................... ................ ............... 98 @ 240V ..I................ 9,7,.5@�240V........................... . Nighttime Power Consumption < 2.5 < 4 W •) ADDITIONAL FEATURES ) Supported Communication Interfaces ........................................... RS485, RS232, Ethernet, 2igBee (optional) .......................................................................................................................... ........... ! Revenue Grade Data, ANSI C12.1 ............................................................................................................................................................................. OptionalI 3/4" minimum / 1-2 strings / 16-6 AWG t Rapid Shutdown — NEC 2014 690.12 Yes AWG ran a ........... g.................................................................................................................. i STANDARD COMPLIANCE f Safety ..rid.Co.necti ....tang.................................................. UL1741, UL1699B, UL1998: CSA 22.2 .............................................................. Dimensions with Safety Switch Grid Connection Standards IEEE1547 . in / Emissions FCC artls class B ' ..........775 x 315 x 260 ................................. INSTALLATION SPECIFICATIONS ) AC output conduit size /AWG range ...................................................... AWG 3/4".minimum.../.16-.6............................. ........................... .... 3/4" mnimum./ AWG DC input conduit size / # of strings / 3/4" minimum / 1-2 strings / 16-6 AWG .i .8-3................. .................. 3/4" minimum / 1-3 strings / AWG ran a ........... g.................................................................................................................. Dimensions with Safety Switch 30.5x12.5x7.2/775x315x184 .............14-6AWG............. 30.5 x 12.5 x 10.5 / . in / ..W?Xw4p)................................................................................................................... ..........775 x 315 x 260 ................................. mm.... Weight with Safety Switch ........................ 5.1.21.23.2 .......... ................... 54.71.24.3 .. ................ ............8.8.-41.404 ............. Ib /.kp... Natural convection Cooling Natural Convection and internal Fans (user replaceable) ' fan (user .............................................................................................................. .replaceable). ............, Noise < 25 . 50 Min. -Max. Operating Temperature Ran a -13 to +140 / 25 to +60 (-40 to +60 version available(')) ......g....................................................................................................................................., Protection Rating NEMA 3R ............................................................................................................................ rU For other regional settings please contact Solar Edge support. RI A higher current source maybe used; the inverter will limit its Input current to the values stated. t31 Revenue grade Inverter P/N: SEnxxA-US0WNNR2 (for 760OW ImrerterSE7600A-1.1500214NR7). NI d0 version P/N: SEznaA-US00oNNU4 (for 760OW inverter.5E7600A-U5002NNU4). Canadian Solar CS6K-275M (18 per string) SolarEdge P400 optimizier 'i. 225A utility meter main — - 240V electric service from utility M ` f • (1) 200A main breaker (1) 60A, 2 pole, backfed solar breaker Circuit 1 Icont = 52.5 A, 240 VAC 5oiartdge SEIOOOOA-US liiveile, (3) #6 THWN-2 (1) 1/C #10 Grid - 6/3 w/G NM -B String 1, typical of 2 strings , #10 PV wire to inverter FM I 1. THE PV SOURCE CIRCUIT IS NEGATIVELY GROUNDED 2. WIRE AND SIZES ARE AS INDICATED OR LARGER. UJ 3. ALL EQUIPMENT IS BONDED BY ENPHASE & UNIRAC INTERGRATED GROUNDING 4. THE ELECTRIC SERVICE PANEL WILL BE CLEARLY LABELED AS FOLLOWS: O "THIS PANEL IS FED BY THREE SOURCES: SOLAR PHOTOVOLTAIC SYSTEM ON PREMISES" "WARNING: ELECTRIC SHOCK HAZARD. DO NOT TOUCH Z TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. " Single Line Drawing Drawn By: David W Client : Eddie Alvarado 13953 Pomegranate Ct, Chico, CA 95973 Date: 06/26/2017 n Scale - NTS 9.9kW DC Photovoltaic System (36 Canadian Solar CS6K-275M) AC CALCULATIONS Circuit 1 Continuous Current = Imax x 1.25 = 42.0 A x 1.25 = 52.5 A Derate Ampacity = 90deg Rating of Conductor (T-310.16) x 90deg Temp Correction Factor (T-310.16) h x Conduit Fill Factor (T-310.15(B)(2)(a) 75 A x .87 x 1.00 = 65.25 A So that, Derate Ampacity > Continuous Current = 65.25 A > 52.5 A >> OK And, Derate Ampacity > Overcurrent Device Rating = 65.25 A > 60A»OK CIRCUIT 1 - SOLAR CIRCUIT MAXIMUM CURRENT: , 42.0 A SOLAR CIRCUIT OPERATING VOLTAGE: 240V (1) SolarEdge SE10000A-US 240(VAC) micro -inverters Pmax (Each): 10950 watts, Imax (Each) = 42.OA, 240(VAC) (36 Total) Canadian Solar CS6K-275M 275W -STC photovoltaic modules. For Each Module: Voc = 38.3 VDC Vmp = 31.3 VDC Isc = 9.31 A Imp =8.80A Enphase & Unirac intergrated bonding NEC 705.12 120% Rule Calclulations Center Fed Panelboard Adjustment - N/A Supply Breakers + 20% <_ Busbar Rating Busbar Rating = 225A - 200A Main 60A Solar 200A + 60A <_ 225A * 1.20 ' 260A:5 270A = OK Rev. Date Description All setbacks to comply regulations. All panels roof ridges and 1' 6" if modules are to be placed or x _ .3' mii (n 1. NEW SYSTEM IS GRID-INTERTIED VIA (1) UL -LISTED POWER CONDITIONING VW 2. INVERTERS - SOLAREDGE SE10000A-US (240 VAC) W/INTEGRATED GROUND SYSTEM IS GROUNDED VIA BONDED COPPER WIRE & UNIRAC BONDING CLIPS. 9. THIS SYSTEM HAS NO UPS, NO BATTERIES 4. THIS IS A ROOF -MOUNTED SYSTEM, ADDING 2.81 LB/sgFT. ROOF IS (1). LAYER . OCOMPOSITION SHINGLES (ROOF SLOPE IS 6:12) ; F. 5. ROOF JOISTS ARE 2X4" ENGINEERED TRUSSES AT 24" O.C. SPACING Z 6. LAG SCREWS ARE 5/16" x 4" AT 72" O.C. MAX, W/3" INTO FRAMING. 7. LABELING DETAIL ON ATTACHED SHEET a Ri m nTrur. TSM STORIES. Roof Plan &Truss Section _ Drawn By: David W Client : Eddie Alvarado 13953 Pomegranate Ct, Chico, CA 95973 Date: 06/26/2017 Scale - NTS 9.9kW DC Photovoltaic System (36 Canadian Solar CS6K-275M) SP SolarEdge inverter Rev. Date Description