Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B17-1295 040-280-070
BUTTE COUNTY AREA DEPARTMENT OF DEVELOPMENT SERVICES 5 INSPECTION CARD MUST BE ON JOB SITE 24 Hour Inspection Line (IVR) : 530.538.4365 (Cut off time for inspections is 3pm) Development Services cannot guarantee inspections on the date requested Office: 530.538.7601 Fax:530.538.7785 www.ButteCountv.net/dds Permit No: B 17-1295 Issued: 6/28/2017 APN: 040-280-070 Address: 6S 6(6 })p(� C -T Owner: THOMAS, KEVIN Permit Type: SOLAR ROOF -RES Description: Install 6.21kw roof mount to existing meter Flood Zone: None SRA Area: No Front: Centerline of Road: Rear: SRA: Street: AG: Interior Total Setback from Centerline of Road: ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING Insvection Tyve IVR INSP DATE Setbacks 131 Foundations / Footings 111 Pier/Column Footings 122 Eufer Ground 216 Masonry Grout 120 Setbacks 131 Do Not Pour Concrete Until Above are Signed Pre -Slab 124 Gas Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing 149 Underfloor Ducts 319 Shear Transfer 136 Under Floor Plumbing 412 Under Slab Plumbing 411 Blockin nde inin 612 Tiedown/Soft Set System 611 Do Not Install Floor Sheathing or Slab Until Above Signed Shearwall/B.W.P.-Interior 134 ShearwalUB.W.P.-Exterior 135 Roof NaiUDrag Trusses 129 417 Manometer Test Do Not Install Siding/Stucco or Roofing Until Above Signed Rough Framing 153 Rough Plumbing 406 Rough Mechanical 316 Rough Electrical 208 4 -Way Rough Framing 128 Gas Piping House 403 Gas Test House 404 Shower Pan/Tub Test 408 Do Not Insulate Until Above Signed Permit Final 802 Electrical Final 803 Mechanical Final 809 Plumbing Final 813 Fire Sprinkler Test or Final 702 Swimming Pools Inspection Type IVR INSP DATE T -Bar Ceiling 145 Stucco Lath 142 Sewer District Final Swimming Pools Setbacks 131 Pool Plumbing Test 504 Gas Test 404 Pre-Gunite 506 Pre -Deck 505 Pool Fencing/Alarms/Barriers 1 503 Pre -Plaster 507 Manufactured Homes Setbacks 131 Blockin nde inin 612 Tiedown/Soft Set System 611 Permanent Foundation System 613 Underground Electric 218 Sewer 407 Underground Water 417 Manometer Test 605 Continuity Test 602 Ski rtin Ste s/Landin s 610 Coach Info Manufactures Name: Date of Manufacture: Model Name/Number: l Numbers: Serial th x Width: h Finals Public Works Final 538.7681 Fire De artment/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final "PROJECT FINAL *Project Final is a Certificate of Occupancy fo idenh On PERMITS BECOME NULL AND VOID I YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY ORA YEAR RENEWAL 30 DAYS PRIOR TO EXPIRATION Design -Driven Advantages #1 module aesthetics and efficiency' Unmatched module reliability' - No electrolytic capacitors 25 -year Combined Power and Product Warranty Maximize Value for Roof Size system for roof, not string inverter Optimize performance of each module Expand Deployment Options Complex roofs and partial shading Small systems System expandability Simplify & Speed Installation Factory -integrated microinverter Robust, double -locking AC connectors Design flexibility offsite and onsite No DC string sizing process Fewer installation steps than competing systems Intuitive commissioning Component of Complete System Built for use with SunPower® InvisiNtountl° and the SunPower Monitoring System Superior system reliability and aesthetics 4M �� d ,e �• r a � SERIES- - . s r Optimize System and Installation Efficiency SunPower° AC Modules, which include a factory -integrated x. SunPower microinverter, provide a revolutionary combination�of high efficiency, high reliability, and module -level DC -to -AC power conversion. n. Designed specifically for use with SunPower Ir-visiMount'".and the ' SunPower Monitoring System, SunPower AC Modules enable rapid ; installation, best -in -class system aesthetics, and intuitive visibility into'.. system performance. All this comes with the test Combined Power and Product Warranty. ` �j sunpower.com L 1 Datasheet S lJ N P ©W E R° PROJECT OWNER: I SCOPE: I PAGE # CONTENT THOMAS, KEVIN 17 BIG DOG COURT DURHAM, CA 95938 APN:040-280-070 PH#:530.895.1522 EMAIL:kevin@thomas-smithcpas.com CONTRACTOR: ALTERNATIVE ENERGY SYSTEMS INC. 13620 HIGHWAY 99 CHICO, CA 95973 CSLB: 853351 C-10, C-46 BUILDING JURISDICTION: BUTTE COUNTY DEPT. OF DEVELOPMENT SERVICES 7 COUNTY CENTER DRIVE OROVILLE, CA 95965 OFFICEM (530) 538-7601 FAX#: (530) 538-2140 MON-FRI 8AM-3PM INSPECTION LINE: (530) 538-4365 REQUESTS PHONED IN BY 2PM WILL BE INSPECTED THE NEXT BUSINESS DAY INSTALL PHOTOVOLTAIC SOLAR SYSTEM ON A TRUSS ROOF, MOUNTED IN ACCORDANCE WITH ALL APPLICABLE BUILDING CODES SPECIFICALLY REFERENCING THE 2016 CALIFORNIA ELECTRICAL CODE/ 2014 NEC USING THE FOLLOWING SPECIFIC EQUIPMENT: 1. MODULES: SUNPOWER (18) SPR -X21 -345 -C -AC 6.21kW SYSTEM 329 SQFT COVERED 2. INVERTER(S): SUNPOWER (18) MODULE INTEGRATED 320W SITE MAP 319.65' PV -1.0 SCOPE PV -2.0 SITE PLAN PV -3.0 ARRAY LAYOUT PV -4.0 ELECTRICAL DIAGRAM PV -4.1 LABEL DIAGRAM PV -5.0 GENERAL NOTES ATTACHMENT MODULE SPECS o ` y INVERTER SPECS o o� RACKING SPECS 17 BIG DOG COURT WIRE CALCS N 100 L..__..__..__..__..—_,.__..—_..__.._J 318.44' N o ' S THOMAS, KEVIN 13620 HWY 99 A o G o ` y p A o o� m 17 BIG DOG COURT CneryyFor Life CHICO, CA 95973 PHONE#: (530) 345-6980 `— s z N o A 019 ° ° ' DURHAM, CA 95938 p p D � ' APN:040-280-070 PH#:530.895.1522 FAX#: (530) 892-2360 Alternative Energy Systems Inc. design@solarenergyforlife.com m < n o n m z „moo A o m 2� , S _ m THOMAS, KEVIN 17 BIG DOG COURT Energy ForLlfe A� or � 13620 HWY 99 CHICO, CA 95973 PHONE#: (530) 345-6980 �`- o Z Z 3 p g DURHAM, CA 95938 � o FAX#: (530) 892-2360 n APN:040-280-070 PH#:530.895.1522 Alternative Energy Systems Inc. design@solarenergyforlife.com i -CODE 3 + y FIRE fn . 13'-11" _ 71 a , OI gal a �. II-- � 24'-4" � 6-0" • RAFTERS 24" ON CENTER - ATTACHMENTS MAX 6' ON CENTER LEGEND a DIRECT . 5' PR 10' PR 31 PP 10' PP �—♦ ' 6' RR'+ - 10' RR [l --{] t RECEN1ICAL END CAP NOTES PLUG END CAP 1.ALL ROOF PENETRATIONS + - PARALLEL CONNECTION 0 TO BE 72" O.C. MAXIMUM r 1 _ ARRAY LAYOUT r .mo THOMAS, KEVIN 13620 HWY 99 m ' Eneryyf orufe CHICO, CA 95973 C Z p_ 17 BIG DO 1 G COURT � _ Z ° ^ `! - �, PHONE#: (530) 345-698 0. . { ° A o m DURHAM, CA 95938 .` d FAX#: (530) 892-2360 - D APN:040-280-070 PH#:530.895.1522 Alternative Energy Systems Inc. design@solarenergyforlife.com a , AC -1 / ON ROOF w/ ' l (2) TRANSITION CABLE_ AC -1 WIRE RUN: S' (2)#10- 2 WIRE NM CABLE CU. l 7 I IMP: 20A WIRE RUN: 60' l 11 l IMAX: 20A � l I l l (18) PV MODULES/INVERTERS JUNCTION l SUNPOWER:SPR-X21-345-C-AC l SOX l 240V/11P/1.33A l ( — — — — — — — — — — — ... AC -2 (1) 3/4" EMT w/ (3) #8 THWN-2 CU. & (1) #10 THWN-2 CU. GRD. WIRE RUN: 30' IMAX: 30A (N)AC DISTRIBUTION PANEL 125A/ 1P/ 240V SERVICE VOLTAGE 130V- 1-L = 40 120V=N-L2-L3=NAV NAV=N-L3-Ll=NAV METE R 200A 1P 240V (E) AC SERVICE PANEL 20OA/ 1P/ 240V SCIR: 22,000 METER#: ########## - AC -MONITORING (1) 1/2" EMT w/ ' (2) 114 THWN-2 CU. & ^ I #14 THWN-2 CU. GRD. ' WIRE RUN: 10' CAT -5 SUNPOWER /TI AI PITOR — � — — MONITORING 1 I d ROUTER ELECTRICAL DIAGRAM THOMAS, KEVIN 13620 HWY 99 17 BIG DOG COURT EnergyFar4fe CHICO, CA 95973 8p DURHAM, CA 95938 ®PHONE#: (530) 345-6980 ®� z r C) FAX#: (530) 892-2360 - APN:- -:.. design@solarenergyforlife.com g gyforlife.com • r - •' n , `` ••' r - �. «. • , ' l i . • i ` r % • ^ it r ' • r ' • • ♦ • . • .. AC PV ARRAY • • - ^ • , C DISCONN cr +' • MAIN • ' UB PANEL lw i t . Jt ..r I - r , t �y .r t `J ALJ `� \J l/ _ \J ." •� .. 1. i � � - , ` 'R� ,`,r. -y ' ♦'� � r '[ �,n •.r' `• •++ . �' • METER AMPS ° - - _ -PHASE - - ' VOLTS r •. WARNING UTILITY INTERACTIVE POWER FLOWING• SOLARKW •' AC OPERATING VOLTAGE: VAC/_PHASE WARNING PHOTOVOLTAIC SYSTEM EQUIPPED DUAL POWER SUPPLY WITH RAPID SHUTDOWN PHOTOVOLTAIC Per NEC 690.54, Interactive Point of Interconnection installed at all Electrical Per NEC 705.10, Point of Connection, Distribution Panel covers that provide a path , Located On Main Service Panel. i from PV to Utility. a PHOTOVOLTAIC DISCONNECT • FOR UTILITY OPERATION Per NEC 690.14, Disconnection means at the single AC Disconnect or Main Breaker. • DO • N RELOCATEOT ' any breaker passing _Solar breaker label @ Bi -Directional Power �;� ti , .. �, ° : ••'� ` �. - � •. � LABEL DIAGRAM n o o 13620 HWY 99THOMAS, KEVIN, £nergyFrLlfe CHICO, CA 9597' 3oN r 17 BIG DOG COURT, t W �.!■I ®�® 6980PHONE#: (530) 345 DURHAM, CA 959 FAX#: (530) 892-2360 — ' N p • a APN:040-280-070 PH#:530.895.1522 Alternative Energy Systems Inc. design@solarenergyforlife.com - ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE 2014 NATIONAL ELECTRIC CODE (NEC), OR LOCAL MUNICIPAL CODE, AND " FIRE DISTRICT REGULATIONS. 1. ALL EQUIPMENT SHALL BE LISTED AND LABELED PER RECOGNIZED ELECTRICAL TESTING LABORATORY AN INSTALLED PER THE LISTING REQUIREMENTS AND THE MANUFACTURER'S INSTRUCTIONS. ,2. ALL INVERTERS SHALL BE IEEE 929 COMPLIANT AND SHALL BE INSPECTED BY LOCAL UTILITY BEFORE COMMISSIONING, TESTING, AND OPERATION OF THE SYSTEM. 15. WHERE MORE THAN ONE NOMINAL VOLTAGE SYSTEM EXIST, THE DIFFERENT SYSTEMS SHALL BE IDENTIFIED BY PHASE AND SYSTEM PER 2014 NEC ART.210AD 16. PROVIDE AN ACCESSIBLE DISCONNECT DEVICE THAT IS LOCKABLE IN OPEN POSITION AND IS LOCATED WITHIN 10'-0" OF THE METER PER LOCAL ELECTRICAL UTILITY REGULATIONS. 17. PHOTOVOLTAIC SOURCE CURRENTS MUST BERATED AT BOTH 125% OF THE PARALLEL MODULE AND AT A CONTINUOUS LOAD OF ANOTHER 125% FOR A TOTAL OF 156% OF THE LOAD. 3. ALL OUTDOOR EQUIPMENT SHALL BE MINIMUM NEMA 3R, INCLUDING OUTDOOR MOUNTED TRANSITION BOXES, COMBINER BOXES, AND SWITCHES. 18. PROVIDE PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE I DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECT MEANS IF THEY ARE 4. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ART.250,690. NOT IN THE SAME LOCATION PER 2014 NEC ART.690.56. 5. NEC. ART. 690.9(A). ALL CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE OVERCURRENT 19. INSTALLATION OF PV PANEL ARRAYS SHOULD RESIST SLIDING AND POP-UP RESULTING FROM DEVICES LOCATED SO AS TO PROVIDE OVERCURRENT PROTECTION FROM ALL SOURCES. SEISMIC EVENTS AND SHOULD COMPLY WITH CBC SECTION 1613A AND ASCE STANDARD 7-05, CHAPTER 13. 6. NEC ART. 690.18. DUE TO THE FACT THAT PV MODULES ARE ENERGIZED WHENEVER THEY ARE EXPOSED TO LIGHT, PV CONTRACTOR SHALL DISABLE THE ARRAY DURING INSTALLATION AND SERVICE BY SHORT CIRCUITING, OPEN CIRCUITING, OR COVERING THE ARRAY WITH AN OPAQUE COVERING. 7. PHOTOVOLTAIC SYSTEM SHALL BACKFEED THE DISTRIBUTION SYSTEM ON SITE PER THE REQUIREMENTS OF NEC ART.690.64(B). ALL BACKFEED BREAKERS SHALL BE IDENTIFIED AS SUCH AND SHALL BE SECURED IN PLACE BY ADDITIONAL FASTENER PER THE REQUIREMENTS OF NEC 408.16(F). 8. FALL ARREST PROTECTION PER OSHA REQUIREMENTS SHALL BE PROVIDED FOR ALL ROOF WORK. 9. ALL CONDUCTORS AND TERMINATIONS SHALL BE RATED FOR 75° C MINIMUM. 10. NEC ART. 690.14. - SEE SHEET RE -4.1 FOR LABEL DIAGRAM 11. NEC ART. 690.53. - SEE SHEET RE -4.1 FOR LABEL DIAGRAM 12. NEC ART. 690.17. EACH AC DISCONNECT SHALL ALSO BE LABELED WITH: "WARNING! -ELECTRICAL SHOCK HAZARD - DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIZE MAY BE ENERGIZED IN THE OPEN POSITION". 20. PV SYSTEM INSTALLER WILL BE RESPONSIBLE FOR FURNISHING AND INSTALLATION OF ALL RELATED EQUIPMENT, CABLES, ADDITIONAL CONDUITS, BOXES WIREWAYS AND OTHER ACCESSORIES NECESSARY FOR COMPLETE AND OPERATIONAL PHOTOVOLTAIC SYSTEMS. 21. PV SYSTEM CONTRACTOR SHALL COORDINATE ALL THE WORK WITH THE ENGINEER, THE CONSTRUCTION MANAGER AND ALL OTHER CONTRACTORS TO ENSURE THAT PV SYSTEM IS INSTALLED AS SPECIFIED IN THESE DRAWINGS. 22. DRAWING IN GENERAL OR DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF THE EQUIPMENT AND WORK INCLUDED. THE INTENTION OF THE DRAWING IS TO INDICATE SIZE, CAPACITY; APPROXIMATE LOCATION AND GENERAL RELATIONSHIP, BUT NOT EXACT DETAIL OR PHYSICAL PLACEMENT. 23. FIELD VERIFIES EXACT AIC RATING REQUIRED OF THE MAIN SWITCHBOARD FROM LOCAL UTILITY. 24. A PV SYSTEM WITH MULTIPLE INVERTERS, WHERE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, WILL HAVE A DIRECTORY CREATED FOR EACH LOCATION. AS PER 2014 NEC 690.5(H) AND IN ACCORDANCE WITH 2014 NEC 705.10. 13. GROUNDING OF ALL DWELLINS SHALL BE CONFIRMED. 25. A NON FOLDING LADDER WILL BE IN PLACE AND SECURED TO THE ROOF TO PROVIDE ACCESS FOR ALL INSPECTIONS. ALL BOXES WILL BE OPENED UPON REQUEST. 14. CONTRACTOR TO PROVIDE GROUND FAULT PROTECTION FOR ROOF MOUNTED PHOTOVOLTAIC ARRAYS LOCATED ON DWELLINGS PER 2014 NEC ART.690.17. 26. SMOKE AND CARBON MONOXIDE ALARMS WILL BE INSTALLED IN ACCORDANCE WITH CRC R314 R315 n m o 13620 HWY 99 Z A m s THOMAS, KEVIN Energy ivrufe C o � gy CHICO, CA 95973 i n po o m 17 BIG DOG COURT 0 o 3 $ o ; DURHAM, CA 95938 Os® PHONE#: (530)345-6980 z A APN:040-280-070 PH#:530.895.1522 Alternative Energy Systems Inc. FAX#: (530) 892 2360 D design@solarenergyforlife.com L LJ �, Output @ 240 V (min./nom./max.) Output @ 208 V (min./no./max.) r SPR -)Q1 -345{ -AC .SPRA21-335{-AC ^O X21 -345 -C -AC I Residential AC Module Series 345 W .335W Power Tolerance ` +5/-0% +5/-0% Avg. Panel Efficiency= 21.5% 21.0% Temp. Coef. (Power) _ -0.30%/° C -Three bypass diodes ' Shade Tolerance' Integrated module -level maximum power • point tracking DC/AC CEC Conversion Efficiency �. �, Output @ 240 V (min./nom./max.) Output @ 208 V (min./no./max.) r SPR -)Q1 -345{ -AC .SPRA21-335{-AC Nominal Power3(Pnom) 345 W .335W Power Tolerance ` +5/-0% +5/-0% Avg. Panel Efficiency= 21.5% 21.0% Temp. Coef. (Power) _ -0.30%/° C -Three bypass diodes ' Shade Tolerance' Integrated module -level maximum power • point tracking �. �, Output @ 240 V (min./nom./max.) Output @ 208 V (min./no./max.) r 211/240/264 Vm 183/208/229 V Operating Frequency (min./nom./max.) 59.3/60.0/60.5 Hz Output Power Factor (min.) - 0.99 AC Max. Continuous Output Curren[ @ 240 V• .AC Max. Continuous Output Current @.208 V 1.33 A 1.54 A AC Max. Cont. Output Power 320 W DC/AC CEC Conversion Efficiency 96.0% Max. Units Per 20 A Branch Circuit @'240 V Max. Units Per 20 A Branch Circuit @ 208 V 12 (single phase) 10 (two pole) ' Highest of over 3,200 silicon solar panels, Photon Module Survey, Feb. 2014 e 110rankin !'PN Module Durabiiiry Initiative Public Report." Fraunhofer CSE, Feb 2013. Fare out of the top eight largest manufacturers were tested. Campeau, Z. et al. 'SUnPower Module Degradation Rate," SunPower white paper, Feb 2013. See www.sunpoweccom/facts for details. ,Standard Test Conditions (1000 w/m' irradiance, AM 1.5, 25° C). IVREL c.3libratIon standlyd: Sol current, LACCS FF and vohage.,411 DC voltage is fully contained within the module. 'Based on average of measured power values during production. See twwvsunpower.conVfaccs for more reference information. For more details, see extended datashee[: vv wasunpowel.com/ciatasheets. �, Operating Temp. -40; F to + C) 185° F (-40° C to +85° Max. Ambient Temp. 122° F.(50° C) Max. Load- . , Wind: 62 psf, 3000 Pa, 305 kg/m2 front & back , Snow: 125 psf, 6000 Pa, 611 kg/m2 front Impact Resistance Vinch (25 mm) diameter hail at 52 mph (23 • m/s) Highest of over 3,200 silicon solar panels, Photon Module Survey, Feb. 2014 e 110rankin !'PN Module Durabiiiry Initiative Public Report." Fraunhofer CSE, Feb 2013. Fare out of the top eight largest manufacturers were tested. Campeau, Z. et al. 'SUnPower Module Degradation Rate," SunPower white paper, Feb 2013. See www.sunpoweccom/facts for details. ,Standard Test Conditions (1000 w/m' irradiance, AM 1.5, 25° C). IVREL c.3libratIon standlyd: Sol current, LACCS FF and vohage.,411 DC voltage is fully contained within the module. 'Based on average of measured power values during production. See twwvsunpower.conVfaccs for more reference information. For more details, see extended datashee[: vv wasunpowel.com/ciatasheets. I Warranties 25 -year limited power warranty 25 ear limited product warranty UL 1741, including compliance with applicable requirements of IEEE 1547 and IEEE 1547.1 AC module Type 2 Fire Raced UL 2703 Listed when installed with InvisiMountT"I Certifications Class A Fire Rated when installed with t. InvisiMounclM and when distance between . roof surface and bottom of Sun Power module frame is <- 3.5" (8.89 cm) Alternating Current (AC) Module designation enables installation in accordance with NEC " 690.6 PID Test Potential -induced degradation free 'f 280 mm [11.02 in] U , 1107 mm [43.6 in] 1046 mm -0p 1 [41.2in] vL • J ' 30 mm' • [1.2 int ' 1558 mm k �- 1 61.3 in] Please read the safety and installation instructions for details. - - r } Document 515215 Rev 3 /LTR US �, Solar Cells 96 Monocrystalline MaxeonO Gen III ' Front Glass High -transmission tempered glass with anti - reflective coating Environmental ' Outdoor, rated . Rating Frame Class 1 black anodized (highest HAMA racing) Weight 45.5 lbs (20.6 k:g) Max. , Recommended 1.3 in. (33 mm) Module Spacing I Warranties 25 -year limited power warranty 25 ear limited product warranty UL 1741, including compliance with applicable requirements of IEEE 1547 and IEEE 1547.1 AC module Type 2 Fire Raced UL 2703 Listed when installed with InvisiMountT"I Certifications Class A Fire Rated when installed with t. InvisiMounclM and when distance between . roof surface and bottom of Sun Power module frame is <- 3.5" (8.89 cm) Alternating Current (AC) Module designation enables installation in accordance with NEC " 690.6 PID Test Potential -induced degradation free 'f 280 mm [11.02 in] U , 1107 mm [43.6 in] 1046 mm -0p 1 [41.2in] vL • J ' 30 mm' • [1.2 int ' 1558 mm k �- 1 61.3 in] Please read the safety and installation instructions for details. - - r } Document 515215 Rev 3 /LTR US 6� ,n Module* / Mid Clamp and Rail Module* / End Clamp and Rail s Mid Clamp. End Clamp.- Rail & Rai.1 Splice -nd Cap Component Material ° Weight Mid Clamp Blacl<oxide stainless steel AISI 30A 63-(2.207) End Clamp Black anodized aluminum alloy 6063-T6 110 g (3.88 oz) Rail Black anodized aluminum alloy 6005-T6 830 g/m (9 oz/fO Rail Splice Aluminum alloy 6005-T5 830 Vm (9 oz/-,'[) Grourd Lug Assembly. 304 stainless (A2-70 bolt; un -placed copper lug) 106.5 g/m (3.75 oz) End Cap Black acetal (POM) copolymer 10.4 g (0.37 oz) Temperature -40° C to 90" C (-40" F to 194° F) Max. Load 2400 Pa uplift 5400 ?a downforce Composition Shingle Rafter Attachrrert Application F' Composition Shingle Roof Decking Attachment ' • • • Curved and Flat Tile Roof Attachment Universal Interface for Other Roof Attachments Refer to roof attachment hardware manufacturer's documentation 4kiodale frame that is compatible with the InwsiMount systam required forbardware tnte,opecabihty r D 201 S Suri`Rower 6rporadon, All Ri3fit's Reserved SUWOVY?k tPe SUWOW=R logo, and IAAhSOWOUNT are trademarks or registered • / ,trademarks of Sun7ower Corporation. All other trademarks are the property of treir tespe.twe owrers. sunpower.com ' Specifications included in this datasheet are subject to change without notice. Documert #509506 Rev 3 Warranties 25 -year product warranty 5 -year finish warranty UL 2703 Listed Certifications Class A fire rating when distance between • N roof surface and bottom of Sun?ower, ` module frame is _ 3.5" Composition Shingle Rafter Attachrrert Application F' Composition Shingle Roof Decking Attachment ' • • • Curved and Flat Tile Roof Attachment Universal Interface for Other Roof Attachments Refer to roof attachment hardware manufacturer's documentation 4kiodale frame that is compatible with the InwsiMount systam required forbardware tnte,opecabihty r D 201 S Suri`Rower 6rporadon, All Ri3fit's Reserved SUWOVY?k tPe SUWOW=R logo, and IAAhSOWOUNT are trademarks or registered • / ,trademarks of Sun7ower Corporation. All other trademarks are the property of treir tespe.twe owrers. sunpower.com ' Specifications included in this datasheet are subject to change without notice. Documert #509506 Rev 3 INVISIMOONT RACKING DETAIL -SOLAR MODULE , END CLAMP MID CLAMP INVISIMOUNT RAIL *EACH MID CLAMP GROUNDS THE �\ MODULE TO THE RAIL [NVISIMOUNT RAIL L-rVV 1 GreenFasten" GFT --Product Guide - Installation Instructions with Compression Bracket MIN �•� 'C' � '� �t}�,+ a �'c Ir.,�•ticrr - 'r'� ,i" t+r Y l � ar.iy✓�/i. 3 ���.v -Yy'' ",�'ri iY' r "i' a ;•,w^ �)+ P k� � � r htr 9 "°Att 7 x SKr l^ a a &; ar;1�i• L rq c„�Y Mt. +c .nY r,� tY �1.T't'.t�r9,r tr trrYYt%i xlP,.FS�O sY`9 — 1 2 3 4a 4b 4c 1. Locate the rafters and snap horizontal and vertical lines to mark the installation position for each GreenFasten flashing. 2. Drill a pilot hole (1/4"diameter) for the lag bolt. Backfill with sealant. EcoFasten Solar recommends an EPDM mastic. 3. Insert the flashing so the top part is under the next row of shingles and pushed far enough up slope to prevent water infiltration through vertical joint in shingles. The leading edge of ' flashing must butt against upper row of nails to prevent turning when tourqued. See page 2.2 for vertical adjustment when leading edge of flashing hits nails in upper shingle courses. 4. Line up pilot hole with GreenFasten flashing hole. 4a Insert the lag bolt through the EPDM washer, the top compression component bracket (L- 102-3, L-102-6*, SCL-101-3*, Z-101", Conduit Mount Bracket*) and the gasketed hole in the flashing and into the rafter. 4b Insert the lag bolt through the EPDM washer, the Comp Mount Slide compression bracket and the gasketed hole in the Flashing and into the rafter. ty�;;� �����i # ' • ( 4 It uel l ll le Idy lJuli ihrouyh 'the ss washer, the third -party bracket, the tNulvl bottled _ washer, the CP -SQ -Slotted compression bracket and the gasketed hole in the flashing and into the rafter. t G+ ,• t . Consult an engineer or go to www.ecofastensolar.com for engineering data. 5. Torque: The range is between 100-140 torque inch -pounds depending on the type of wood and time of year. The visual indicator for proper torque is when the EPDM on the underside of the bonded washer begins to push out the sides as the washer compresses. If using an impact wrench to install the fasteners be careful not to over torque the fastener. You may .t need to stop aril use a ratchet to finish the install. - !t; : *not pictured. 877-859-3947 EcoFasten Sola' All content protected under copyright. All rights reserved. 7/24/2014 2• j rA f tl,�l rF' f• EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 132 8,153,700 132 8,181,398 B2 8,166,713 B2 8,146,299 132 8,209,914 B2 8,245,454 132 8,272,174 132 8,225,557 82 ' GreenFusten~GFl — Product Guide Installation Instructions * Use for vertical adjustment when leading edge of flashing hits nails in upper shingle courses 1'Slide flashing upunder shingles until leading edge engages nails. Measure remaining distance toadjust lincinno ;hiogle 2.Remove flashing and cut "V~notch atmarks where nail shafts engaged leading edge offlashing the distance desired inStep 1. Notch depth not to exceed 2" length by 1/2" width. | notch | ^~ 3.Reinstall flashing with notched areaupdope x1'Position notched leading edge underneath nail heads as shown. . ~ . ath shingle Nails beneath shingle \ . 877-859-3947 enoraom^avlarAll content protected under copyright. All rights reserved. 7owuow EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 B2 8,153,700 B2 8,181.398 B2 8.166,713 B2 8,146,299 82 8,209,914 B2 8,245,454 B2 8,272,174 B2 8,225,557 B2 %2 GreenFasten"GFI.-T oduct Guide �, ' = ' f_ ' Cut Sheets: GF1 J.'e �- -•7. 3 -� '..cam' _.M ' w.. L. ! _ Y; w f' ��� f _tA SECTION A -A j1f:04'T _ ��if f` 877-859-3947 EcoFasten Solar4lAll content protected under copyright. All rights reserved. 7/24/2014 , ' 3.1 EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 B2 8,153,700 B2 8,181,39.8 B2 8,166,713 82 8,146,299 B2 8,209,914 B2 8,245,454 B2 8,272,174 B2 8,225,557 B2 ---------- ------- --------------------- �J— • f _tA SECTION A -A j1f:04'T _ ��if f` 877-859-3947 EcoFasten Solar4lAll content protected under copyright. All rights reserved. 7/24/2014 , ' 3.1 EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 B2 8,153,700 B2 8,181,39.8 B2 8,166,713 82 8,146,299 B2 8,209,914 B2 8,245,454 B2 8,272,174 B2 8,225,557 B2 GreenFasten'"" GF,1 — Product -Guide ` a y ; 3 f ` T Cut Sheets: GF1- 812 � ( t V t. f � , .•ry =-- ''t•R. 4. � +3. - •. �!y� � �r�, �- ',�• .0 ,LF. .ry:-. - aJ.t - � `,F ' .. - • r, d 4X R—" • —�' •l /32" P j(j(rr t 1 8 S 16 5/64 111��1 '1� #il P r� • • , M y , l . f r _ 16' . •, SIJ DETAIL A 4" - y SCALE: 2:1 n 1 � Jt• t� R a -Finish Options `'x -BLK Matte Black .MLL=Mill Finish i 1 877-859-3947 EcoFasten Solar All content protected under copyright. All rights reserved. 7/24/2014 3,2 EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 132 8,153,788 132 8,161,3983 132 8.166,713P2 8,146,299 132 8,289,914 132 8,245,454 132 4,272,174 82 8,225,557 D2 GreenFasten'" GF1 - Product Guide ' M : Cut Sheets: Bracket�Options - CP -SQ -Slotted a ♦ c 1.50 9�1 .0+6 — _ .50 4 , t. ........... 2.00 .......... _.- EI / �- E _ 1.00 1. 7 0 0.88±.01 X 82' 2.00 j 1 t E. yf } i 1 ►► 877-859-3947'EcoFasten Solar�All content protected under copyright. All rights reserved. 7/24/2014 3.3 tr ry4 �j� -}. �� EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 B2 8,153,700 B2 8,181,398 82 8,166,713 B2 8,146,299 B2 8,209,914 B2 8,245,454 B2 8,272,174 B2 8,225,557 B2 r: GreenFasten' GF1 - Product Guide *. ' • -' c 'Cut Sheets: Bracket Options - SCL-101 -3" 3/8„ k cc_ '46 SERRATIONS A. I" � F f U-) 1/,4" 00 ' „It • • ` Rbo ` `` 2X R.OI w 7 err' -�-- 60.00 0 3/8' 1 /8 - .002- "• k— — 0 7/8, X,82 0 DETAIL A F (A ! SCALE 3:1 ; i y 877-859-3947 EcoFasten Solar All content protected under copyright'All rights reserved. 7/24/2014 s 3.5 EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 B2 8,153,700 B2 8,181,398 B2 8,166,713 B2 8,146,299 B2 8,209,914 B2 8,245,454 B2 8,272,174 B2 8,225,557 B2 'f 46 SERRATIONS 10 V) - t t i� 1 7/8�� !1 3/4.. � � 4 1.. 00 !;�\tart •,' / .\ 1 /16" A'10 R.005 I V) f 1 + R.010 2 X R.61 60.00° .. t 03"-.002' �j 3/8"+.006 - - - .002 1 /8' + DETAIL A I ,t 0.875 _.010 X 82 k1' SCALE 3 1 +S1 _ tit 877-859-3947 EcoFasten Sola& All content protected under copyright. All rights reserved. 7/24/2014 3.6 EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 82 8,153,700 132 8,181,398 B2 8,166,713 B2 8,146,299 B2 8,209,914 B2 8,245,454 82 8,272,174 B2 8,225,557 S2 , 1/7 N X N 15/16" 1 7/8" !1 3/4.. � � 4 1.. 00 !;�\tart •,' / .\ 1 /16" A'10 R.005 I V) f 1 + R.010 2 X R.61 60.00° .. t 03"-.002' �j 3/8"+.006 - - - .002 1 /8' + DETAIL A I ,t 0.875 _.010 X 82 k1' SCALE 3 1 +S1 _ tit 877-859-3947 EcoFasten Sola& All content protected under copyright. All rights reserved. 7/24/2014 3.6 EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 82 8,153,700 132 8,181,398 B2 8,166,713 B2 8,146,299 B2 8,209,914 B2 8,245,454 82 8,272,174 B2 8,225,557 S2 , AC Circuit Ampacity Calculator .: Meter # O,r.��� ' Customer Name:THOMAS 'KEVIN -Location: BIG DOG COURT, Durham, CA 95938 Wire Note: AC -1 Description: INVERTER TO AC DISTRIBUTION PANEL ;3r e Calculation 52 kWatts 240 VAC s " Split Voltage Configuration. � . �.. TRUE TE Inverter? 0 Minimum Wire and Conduit Size based on Voltage Drop and Ampacity 10 Minimum Ground Size Based on NEC • 18.33 A Minimum Ciruit Breaker/Fuse Size - L - 10 Actual Ground Size Based on NEC ' • 18.33 A Ampacity After Derate _ 10 Wire Size Based on Ampacity 30 A - 0.4547 % of Voltage Drop •` 10 Wire Size Based on Voltage Drop' 301A 14.667 A Circuit Ampacity • Factor '" 1 Phases + 0.96 Conditions of Use Derate Factor 15.28 A Minimum Conductor Ampacity Based on Conditions of Use - - 18.33 A Minimum Conductor Ampacity Based on 1.25 Rule Conditions of Use 0.96Derate Total 35 °C Temp Coef (ambient + Sunlight) 95 °F r 0.96 Derate 35 °C Ambient Temp 95 °F none Sunlight Exposure 32 °F 00 °C Temp adder 3 or less Number of Current Carrying Conductors LTJ Derate applied to Temp Coeficient Voltage Drop: Allowable Tolerance (Solar Generation 1%, Distribution 3%) 240V Circuit Voltage - 14.667 A Circuit Amps 1.24 Resistance 36JV- One Way Distance 10 ]WireSize �-0.45471% of Loss Conduit Size (Conduit Fill Can Not be more than 40%) Nonet Conduit Type 0.16. _ Wire Size Diameter FTttN/A Conduit Fill percentage 1 Conduit Size 0.16 Ground Wire Size Diameter #N/A Conduit Internal Diameter 600 V _ System Voltage r �'..., ,_ THWN-2 Wire Type fAC Circuit Ampacity Calculator _ _ - Meter #: 0 -�' Customer Name: THOMAS, KEVIN' . Location: BIG DOG COURT, Durham, CA 95938 Wire Note: AC -2 Description: AC DISTRIBUTION PANEL TO AC SERVICE PANEL - ' "5� lculation y ��_ kWatts _ 240 VAC- r- S lit V I ?�"*_ p o tage Configuration - ` TRUE TL Inverter tMinimum Wire and Conduit Size based on Voltage Drop and Ampacity . 10 Minimum Ground Size Based on NEC ' f: • = ' 30.00A Minimum Ciruit Breaker/Fuse Size'.- = 10 Actual Ground Size Based on NEC ; 30.00 A Ampacity After Derate 8 Wire Size Based on Ampacity 55 A - 0.1.556 % of Voltage DropWire Size Based on Voltage Drop • ' 55 A 24 A Circuit Ampacity, Factor 1 Phases 0.82 Conditions of Use Derate Factor 29.27 A Minimum Conductor'Ampacity Based on Conditions of Use 30.00 A Minimum Conductor Ampacity Based on 1.25 Rule - 0.82 Derate Total f 50 °C Temp Coef (ambient + Sunlight) 122 °F 0.82 Derate 50 °C Ambient Temp 122 °F _ none Sunlight Exposure Y r 32 °F 0 °C Temp adder 4 3 or less Number of Current Carrying Conductors 1 Derate applied to Temp Coeficient Voltage Drop: Allowable Tolerance (Solar Generation 1%, Distribution 3%) 2�1 0 V Circuit Voltage 24 A Circuit Amps 0.778 Resistance 0 ft One Way Distance r 8 Wire Size 1 0.1556 % of Loss - y Conduit Size (Conduit Fill Can Not be more than 40%) ' EMT Conduit Type y 10.�212 Wire Size Diameter 24% Conduit Fill nPrrPntagp ,3/4 Conduit Size .16 Ground Wire Size Diameter 0.533 Conduit Internal Diameter 600 V System Voltage THWN-2 Wire Type s1 - r -. ' .. '. " - � '- _. •:o - '�� .. -• +.' ` �. � =moi _ .�;; - t + J .',;.•qx, v.• - A ,•} •r -JA ,, �^ .k.;^'i 4: a� ..Y ... y. '•y',•s.`i t ` • ..,. ... . ti W� ,-.-. .F'a .y .�•�,,,.,, ,' ..-• s _