Loading...
HomeMy WebLinkAboutB17-1425 047-340-024BUTTE COUNTY AREA EL� DEPARTMENT OF DEVELOPMENT SERVICES 4 S 4' INSPECTION CARD MUST BE ON JOB SITE 24 Hour Inspection Line (IVR) : 530.538.4365 (Cut off time for inspections is 3pm) Development Services cannot guarantee inspections on the date requested evelorrwer+r SERVICE Office: 530.538.7601 Fax: 530.538.7785 www.ButteCounty.net/dds Permit No: B17-1425 Issued: 7/14/2017 APN: 047-340-024 Address:. 60 ELITE DR, CHICO Owner: Joseph N. Gallaty, Wendy E. Gallaty Permit Type: SOLAR ROOF -RES Description: Joe Gallaty Solar Roof Mount Flood Zone: None SRA Area: No 9FTRACKS for Zoneng- AG_ SRA. PW Front: Centerline of Road: Rear: SRA: Street: AG: - Interior Total Setback from Centerline of Road: ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING t` Inspection Type IVR INSP DATE Setbacks 131 + Foundations / Footings 111 Pier/Column Footings 122 Eufer Ground 216 Masonry Grout 120 Setbacks 131 Do Not Pour Concrete Until Above are Signed Pre -Slab 124 Gas Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing 149 Underfloor Ducts 319 Shear Transfer 136 Under Floor Plumbing 412 Under Slab Plumbing 411 Blockin nde inin 612 Tiedown/Soft Set System 611 Do Not Install Floor Sheathing or Slab Until Above Signed Shearwall/B.W.P.-Interior 134 Shearwall/B.W.P.-Exterior 135 Roof Nail/Drag Trusses 129 417 Manometer Test Do Not Install Siding/Stucco or Roofing Until Above Signed Rough Framing 153 Rough Plumbing 406 Rou h Mechanical 316 Rough Electrical 208 4 -Way Rough Framing 128 Gas Piping House 403 Gas Test House 404 Shower Pan/Tub Test 408 Do Not Insulate Until Above Signed Permit Final 802 Electrical Final 803 Mechanical Final 809 Plumbing Final 813 Fire Sprinkler Test or Final 702 Swimming Pools Inspection Type IVR INSP DATE T -Bar Ceiling 145 Stucco Lath 142 Swimming Pools Setbacks 131 Pool Plumbing Test 504 Gas Test 404 Pre-Gunite 506 Pre -Deck 505 Pool Fencing/Alarms/Barriers 503 Pre -Plaster 507 Manufactured Homes Setbacks 131:. Blockin nde inin 612 Tiedown/Soft Set System 611 Permanent Foundation System 613 Underground Electric 218 Sewer 407 Underground Water 417 Manometer Test 605 Continuity Test 602 Ski rting/Steps/Land i fis 610 Coach Info Manufactures Name: Date of Manufacture: Model Name/Number: Serial Numbers: Length x Width: Insignia: Public Works Final . - 538.7681 Fire De artment/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final "PROJECT FINAL *Project Final is a Certificate of Occupancy 4.7 PERMITS BECOME NULL AND VOID I YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A I YEAR RENEWAL 30 DAYS PRIOR TO EXPIRATION } � s Carbon monoxide alarms required by Sections R315.1 and R315.2 shall be installed in the following locations: 1. Outside of each separate dwelling unit sleeping area in the immediate vicinity of the bedroom(s). 2: On every level of a dwelling unit including basements. R315.1.5 Multiple -purpose alarms: Carbon monoxide alarms combined with smoke alarms shall comply with Section R315, all applicable standards, and requirements for listing and approval by the Office of the State Fire Marshal, for smoke alarms. Butte County's Interpretation of 2013 CRC, Sections 314 & 315 for Smoke Alarms & Carbon Monoxide Alarms: Where alterations, repairs or additions exceeding $1,000 in valuation, existing dwellings shall be retrofitted with smoke alarms and those that have attached garages or fuel -burning appliances shall have carbon monoxide alarms installed. Existing smoke alarms can be replaced with dual function alarms for Smoke and Carbon Monoxide and in most cases will comply with the aforementioned code requirements for Carbon Monoxide Alarms. DECLARATION OF INSTALLATION UNDER THE PENALTY OF PERJURY As Owner/Contractor, I/we affirm and declare under the penalty of perjury, under the laws of the State of California, by our signatures below as Owner/Contractor, that I/we will comply prior to final inspection with Items A & B as specified herein: A. Both Owner/Contractor have read and clearly understand the aforementioned 2010 California Residential Code (CRC) Carbon Monoxide Alarm requirements. B. Both Owner/Contractor are responsible for installing Carbon Monoxide Alarms prior to final inspection as per the aforementioned building code and maintaining such installation. Smoke Alarms will also be installed prior to final inspection as per the 2010 CRC. Smoke and Carbon Monoxide alarms are now installed in the following locations: 1 C;/'�►'?�►J �1�' /rt -cam- , I VJ'�If- (��Jui�n� I (,�Y,T/y.�, �rw. i O��i1•/�1, naxci�y Owner's name (print): `TO, Gpu,gr�.( Owner's signature: ate: 7127//7' Contractor's nam0print): .-�U SQL CSLB License Contractor's signature: / � _ Date: 7/L7117 Project Address: FLrrr---VrL. L44CZ-o Permit #: tG ZIK-�Xf. Page 2 of 2 Revised 7.20.2015 Butte County Department of Development Services FORM NO PERMIT CENTER 7 County Center. Drive, Oroville, CA 95965 DBI -01' mn.. ea+,cu Main Phone (530) 538-7601 Fax (530) 538-7785 WWW.buttecounty.net/dds Declaration of Installation for Smoke Alarms and Carbon Monoxide Alarms The newly adopted 2013 California Residential Code requires the installation of Carbon Monoxide Detectors in dwelling units and in sleeping units within which fuel -burning appliances are installed and in dwelling units that have attached garages. The policy for Carbon -Monoxide Alarms in Butte County states: "Any permit obtained in which the value of work exceeds $1000 associated with a Residential Group R Dwelling Unit or Sleeping Unit shall conform to the following 2013 California Residential Code requirements for Smoke and Carbon Monoxide Alarms (Section R314 & R315)." 2013 California Residential Code requirements for Carbon Monoxide Alarms: R315.1 New construction: An approved carbon monoxide alarm shall be installed in dwelling units and in sleeping units within which fuel -burning appliances are installed and in dwelling units that have attached garages. R315.1.2 Power supply: For new construction required carbon monoxide alarms shall receive their primary power from the building wiring where such wiring is served from a commercial source and shall be equipped with a battery back=up. Alarm wiring shall be directly connected to the permanent building wiring without a disconnecting switch other than as required for over - current protection. Exceptions: 1. In dwelling units where there is no commercial power supply the carbon monoxide alarm may be solely battery operated. 2. Tn existing dwelling units a carbon monoxide alarm is permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling fmishes or there is no access by means of attic, basement or crawl space. R315.1.3 Interconnection. Where more than one carbon monoxide alarm is required to be installed within the dwelling unit or within a sleeping unit the alarm shall be interconnected in a manner that activation of one alarm shall activate all of the alarms in the individual unit. Exception: 1. Interconnection is not required in existing dwelling units where repairs do not result in the removal of wall and ceiling finishes, there is no access by means of attic, basement or crawl space, and no previous method for interconnection existed. R315.2 Where required in existing dwellings: Where a permit is. required for alterations, repairs or additions exceeding one thousand dollars ($1,000), existing dwellings or sleeping units that have attached garages or fuel -burning appliances shall be provided with a carbon monoxide alarm in accordance with Section R315.1. Carbon monoxide alarms shall only be required in the specific dwelling unit or sleeping 'Unit for which the permit was obtained. R315.2.6 Alarm requirements: No person shall install, market, distribute, offer for sale or sell any carbon monoxide device in the State of California unless the device and instructions have been approved and listed by the State Fire Marshal. Pagel of 2 Revised 7.20.2015 Y.: N ya. LOCATION MAP. _ A •ti f •• S:. A - ^ - 1V GA•L.®LATY'--RESIDEN�CE,.,.,.,.1 - .NET MEQ'}FRED 13.200.kW PV'.' . Y A4_ � �.�t_ 1•• ''f' T.. '1f' , w ♦ _ - .As. - y Y , � n• '.b ' ., •F:Y yy I•J• M w DATE: 7/12/2017 ^APPL'ICABLE CODES / NOTES: THIS SOLAR PHOTOVOLTAIC SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS SPECIFIED IN ARTICLE 690 OF THE 2016 CEC AND ALL APPLICABLE BUILDING CODES.(REFER TO PAGE 6) ' -jam •a .x ... ^BY: .f SYSTEM SPECIFICATIONS: =' r '� �' 60 ELITE DR TABLE OF CONTENTS' DRAWN w * f CS6K-275M MODULE: CANADIAN SOLAR (48 MODULES) _ ° s CHICO, CA 95973 = .' .. P.1 COVER SHEET u J B STRING -'INVERTER: ENPHASE M215-60-2LL MICROS _ ' CLIENT PHONE # ' . P.2 '• 'SITE PLAN -. n AZIMUTH(S): 180°• _ 530-519-9555` f ` P.3' MODULE LAYOUT REV. TILT(S) : 16° +BUSBAR RATING: 200A R , _ 380 ORANGE ST JURISDICTION: PA MOUNTING DETAILS . MAIN BREAKER:' 120A. ^° CHICO, CA 95928 _ CITY OF CHICO P.5 ' ELETRICAL.SCHEMATIC ATTACHMENT TYPE: UNIRAC PV COMP SHINGLE MOUNT - 1(855)360 -JOIN UTILITY: P.6 ELETRICAL'NOTES • - ` LIC #: 1021484' . _ PG&E ' P.7 STICKER / PLACECARDS N 1 SITE PLAN PV2 SCALE 1: 10 60 ELITE DR TABLE OF CONTENTS # OF MODULES: CHICO, CA 95973 P.1 COVER SHEET 48 (1,3.200 kW) AZIMUTH(S): CLIENT PHONE # P.2 - SITE PLAN MODULE TYPE: 1800. 5301-519-9555 P.3 MODULE LAYOUT TI LT()3760 MORROW LANE SUITE o _ JURISDICTION: PA MOUNTING DETAILS CANADIAN SOLAR ,. CHICO, CA 95928 CITY OF CHICO P.5 ELETRICAL SCHEMATIC . CS6K-275M 160 1(855)360 -JOIN UTILITY: P.61 ELETRICAL NOTES LIC #: # : 1021484 PG&E I P.71 STICKER / PLACECARDS MECHANICAL FASTENING/ MOUNTING. REFER PAGE 4 FOR SECTION UNIRAC STANDARD RAILING DETAIL & ATTACHMENT INFO. LOCATE (2) PER MODULE PER MANUFACTURES GUIDELINES. REFER TO PAGE 4 FOR SECTION DETAILS 1 MODULE PLAN MAX 2'-4" CANTILEVER PAST SUPPORT PV3 SCALE 1 : 10 ` - VERIFY ALL OBSTRUCTIONS IN THE FIELD 60 ELITE .DR TABLE OF CONTENTS - VERIFY ALL DIMENSIONS IN THE FIELD. - WHERE INDICATED ON PLAN MIN. CHICO, CA 95973 P.1 COVER SHEET DIMENSIONS ARE REQUIRED PER THE _ CLIENT PHONE # P.2.- SITE PLAN "SOLAR. PV INSTALLATION GUIDELINE" 530-519-9555 P.3 MODULE LAYOUT - PROVIDE RAIL SPLICES AS REQUIRED BY .JURISDICTION: MANUFACTURE'S GUIDELINES. 3760 MORROW. LANE SUITE D PA MOUNTING DETAILS - PV MODULE CANNOT BE INSTALLED OVER,3' FIRE CODE OFFEST CHICO, CA 95928 CITY OF CHICO P.5 ELETRICAL SCHEMATIC OR BLOCK ATTIC VENTS, PLUMING VENTS, 1(855)360 -JOIN UTILITY: P.6 ELETRICAL NOTES FURNACE OR WATER HEATER VENTS ETC. PG&E LIC # :1021484 P.7 STICKER / PLACECARDS } r I• MOUNTING CLIP, TYP . ✓ r . - } MOUNTING CLIP, TYP . UNIRAC STANDARD RAIL PE4 - L—FOOT SOLAR `MODULE . .. PLYWOOD UNIRAC PV COMP SHINGLE MOUNT -MAX COMP SHINGLE RAFTER ROOF TILT: 16° OR TRUSS P (2) 5/ 1.6"O x a4" O R 4 1 /2", . . 18-8 SS LAG SCREWS, TYP. 2 1/2" MIN. EMBEDMENT LOADING: " - ARRAY SELF WEIGHT: RAIL MAXIMUM ALLOWABLE SPANS PROVIDED BY , 3 MODULE: 40.8 LB OVER 17.3 SF = 2.35 PSF MANUFACTURER (SEE PAGE 3 FOR PROVIDED MOUNT SPACING) RAIL: 0.54 PLF, (2) PER 64.5" MODULE = 0.2 PSF PER ASCE 7=10, SECTION 6.4.2.2 & FIG. 6-3 MISC: CLAMPS, HARDWARE, WIRING, ETC. = 0.2 PSF „MAXIMUM UPLIFT:.6 D+W = 158 LB < 237 LB .. .. ARRAY SELF -WEIGHT = 2.75 PSF MAXIMUM DOWNFORCE: D+W = 218 LB < 237 LB . - MAX., WEIGHT PER ANCHOR = 44.6 LB (FOR 4'-0" SPANS) 60 ELITE DR TABLE OF CONTENTS, WEATHER LOADING: RAILING: CHICO, CA 95973 P.1 COVER SHEET GROUND SNOW:. 0 PSF UNIRAC CLIENT PHONE # P.2 'SITE PLAN r WIND SPEED: 85 MPH STAND RAILING 530-519-9555 P.3 MODULE LAYOUT' PV ARRAY: 2.75 PSF - 3760 MORROW LANE SUITE D JURISDICTION: PA -MOUNTING DETAILS-, EXPOSURE CATEGORY: b MOUNTING: cHlco, cA s5s28 CITY OF CHLCO P.5 ELETRICAL SCHEMATIC UNIRAC PV 1(855)360 -JOIN UTILITY: P.6 ELETRICAL NOTES COMP SHINGLE uc #: 1021484 PG&E -I P.71 STICKER /. PLACECARDS MANUFACTURERL APPROVED MODEL CANADIAN SOLAR CS6K-275M INVERTER - UL MANUFACTURERPPROVED MODEL ENPHASE M215 ELECTRICAL SPECIFICATIONS P.1 COVER SHEET ELECTRICAL SPECIFICATIONS P.3 MODULE LAYOUT RATED POWER OUTPUT @ STC 275 RATED AC VOLTAGE 240V OPEN CIRCUIT VOLTAGE (Voc) 38.3V CEC EFFICIENCY 96.5% MAX POWER VOLTAGE (Vmp) 31.3V MAX POWER OUTPUT @ STC 225W. SHORT CIRCUIT CURRENT (Isc) 9.31A MAX INPUT VOLTAGE 48V MAX POWER CURRENT (Imp) 8.80A MAX INPUT CURRENT 15A Voc CORRECTION FACTOR (%/deg C) -0.31 % MPPT VOLTAGE RANGE 183V - 229V Vmp/Pmp CORRECTION FACTOR -0.41% MAX OUTPUT CURRENT 0.9A. (N) 100A 2 POLE BREAKER TO UTILITY GRID SHALL BE INSTALLED 120/240V OPPOSITE TO THE MAIN SINGLE PHASE T MAIN RESIDENCE-/ ESIDENCE BREAKER NOT CENTER FED PANEL BI-DIRECTIONAL UTILITY METER I,MAIN C' PANEL 00 A 40 60 ELITE DR CHICO, CA 95973. CLIENT PHONE # 530-519-9555 JURISDICTION: CITY OF CHICO UTILITY: PG&E ©moi© P.1 COVER SHEET P.2 SITE PLAN P.3 MODULE LAYOUT PA MOUNTING DETAILS P.5 ELETRICAL SCHEMATIC :::::::::::::I P.7 STICKER / PLACECARDS � c lo. _© _ 1..Rooms ■.....■I 1■■■..■■.■■■■■■ n SUB ELECTRICAL PANEL (N) 125 AMP 120/240) c>3 =1A Fes= I, ;m ---- ------ FF_ i MOUNTS AND EQUIPMENT I ENCLOSURES GROUNDED I TO MAIN PANEL GROUND -1- COMPONENT CONNECTIONS WILL BE MADE WITH: (E) LIFER GND (UNLESS OTHERWISE SPECIFIED) EXTERIOR 2" EMT AC CONDUIT OR INTERIOR ROMEX 10-3 (3) #10 CU THWN-2 (1) #8 CU GROUND 90°C WET & DRY SYSTEM OVERVIEW # OF MODULES IN SERIES (CIRCUIT SIZE) 16, 16, 1f # OF MODULES IN PARALLEL (# CIRCUITS) 3 NUMBER OF MODULES PER INVERTER 1 ARRAY RATED DC POWER OUTPUT @ STC 13.200kV1 #6 CU AWG BARE WIRE (TYP) BOUNDING MODULES & RAILS J- BOX UNDER ARRAY SEALED TIGHT NON-FUSED -NEMA TYPE3 MIN. ENVOY S XAM1-120M COMBINER BOX 16 PANELS— BRANCH CIRCUIT #1 EATON MICR04NVERTER 01 MICR04NVERTER 12 (N) 55A 2 POLE BREAKER SHALL BE INSTALLED OPPOSITE OF MAIN BREAKER (N) 5/8".0 MIN. 8' IN SOIL CU ELECTRODE MIN. 6' APART FROM EXISTING LIFER TERMINATOR CAP ON LAST CABLE CONNECTOR OF AC TRUNK CABLE (TYP) MICR04NVERTER#15 MICRO -INVERTER #16 - INVERTER (TYP.) #16 MICRO - INVERTER (TYP.) 12 PANELS— BRANCH CIRCUIT #3 MICRO -INVERTER TRUNK CABLE, 1 PHASE 90°c, 600V, WET/DRY, WITH MICRO -INVERTER PRE-INSTALLED CONNECTORS OPEN AIR CONDUCTORS, NOT IN A CONDUIT BLACK -1_1 RED-L2,WITH-NEUTRAL GREEN -GROUND UL1741, UL 746 C,F1, IEC 60529 IP67 (TYP) AI ' BUSBAR RATING: 200A MAIN BREAKER: 120A # OF MODULES: 48 - SYSTEM SIZE (kW):13.200.CHICO, • 3760 MORROW LANE SUITE D CA 95928 1(855)360 -JOIN CIC #: 1021484 60 ELITE DR CHICO, CA 95973. CLIENT PHONE # 530-519-9555 JURISDICTION: CITY OF CHICO UTILITY: PG&E TABLE OF CONTENTS P.1 COVER SHEET P.2 SITE PLAN P.3 MODULE LAYOUT PA MOUNTING DETAILS P.5 ELETRICAL SCHEMATIC :::::::::::::I P.7 STICKER / PLACECARDS 1..Rooms ■.....■I 1■■■..■■.■■■■■■ mc MICRO -INVERTER #1 MICROANVERTER #2 .K e m MICR04NVERTER #I MICR04NVERTER #2 .will ii (N) 55A 2 POLE BREAKER SHALL BE INSTALLED OPPOSITE OF MAIN BREAKER (N) 5/8".0 MIN. 8' IN SOIL CU ELECTRODE MIN. 6' APART FROM EXISTING LIFER TERMINATOR CAP ON LAST CABLE CONNECTOR OF AC TRUNK CABLE (TYP) MICR04NVERTER#15 MICRO -INVERTER #16 - INVERTER (TYP.) #16 MICRO - INVERTER (TYP.) 12 PANELS— BRANCH CIRCUIT #3 MICRO -INVERTER TRUNK CABLE, 1 PHASE 90°c, 600V, WET/DRY, WITH MICRO -INVERTER PRE-INSTALLED CONNECTORS OPEN AIR CONDUCTORS, NOT IN A CONDUIT BLACK -1_1 RED-L2,WITH-NEUTRAL GREEN -GROUND UL1741, UL 746 C,F1, IEC 60529 IP67 (TYP) AI ' BUSBAR RATING: 200A MAIN BREAKER: 120A # OF MODULES: 48 - SYSTEM SIZE (kW):13.200.CHICO, • 3760 MORROW LANE SUITE D CA 95928 1(855)360 -JOIN CIC #: 1021484 60 ELITE DR CHICO, CA 95973. CLIENT PHONE # 530-519-9555 JURISDICTION: CITY OF CHICO UTILITY: PG&E TABLE OF CONTENTS P.1 COVER SHEET P.2 SITE PLAN P.3 MODULE LAYOUT PA MOUNTING DETAILS P.5 ELETRICAL SCHEMATIC P.6 ELETRICAL NOTES P.7 STICKER / PLACECARDS - EACH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION POINT -THIS SOLAR PHOTOVOLTAIC SYSTEM.SHALL BE INSTALLED IN • .,PER MANUFACTURE'S REQUIREMENTS: ALL SOLAR MODULES EQUIPMENT, AND ACCORDANCE WITH THE.REQUIREMENTS SPECIFIED IN ARTICLE 690 THE METALLIC COMPONENTS ARE TO BE BONDED. IF THE EXISTING OF,THE 2016 CEC AND ALL APPLICABLE BUILDING CODES: GROUNDING ELECTRODE SYSTEM CAN NOT BE VERIFIED OR ONLY METALLIC - WATER PIPING, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A - ACCESS TO THE ELECTRICAL WIRE SHALL BE RESTRICTED TO SUPPLEMENTAL GROUNDING ELECTRODE. •'QUALIFIED'PERSONAL ONLY AS REQUIRED.BY ARTICLE 690 OF THE 2016 CEC: ALL PLAGUES AND SINGAGE REQUIRED BY THE LATESTEDITION-OF NATIONAL + ELECTRICAL CODE. REFER TO SHEET 7 (STICKERS AND,PLACECARDS). LABEL - THE PHOTOVOLTAIC ARRAY(S) SHALL BE PROVIDED WITH. DC SHALL BE METALLIC OR PLASTIC, ENGRAVED OR MACHINED PRINTED IN A GROUND -FAULT PROTECTION. (CEC 690.5) CONTRASTING COLOR TO THE PLAQUE. PLAQUE SHALL BE UV- RESISTANT IF EXPOSED TO SUNLIGHT. - ALL CONDUCTORS SHALL BE TYPE 90 DEGREE,C RATED. (CEC - 690.318) :o - DC CONDUCTORS SHALL BE RUN -IN EMT AND/OR MC (METAL CALD CABLE) AND SHALL BE LABELED, "CAUTION DC CIRCUIT" OR EQUIV. EVERY 5 FT. - ALL EXPOSED PHOTOVOLTAIC SYSTEM.CONDUCTORS SHALL BE - TYPE USE -2 OR PV WIRE. (CEC 690.31 B) .. - EXPOSED NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT - - SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136 (A) - ALL CONDUCTORS SHALL BE TYPE 90 DEGREE C RATED (CEC 690.318) - CONFIRM LINE SIDE VOLTAGE AT ELECTRICAL UTILITY SERVICE PRIOR TO CONNECTING INVERTER. VERIFY SERVICE.VOLTAGE IS WITHIN INVERTER -THE INSTALLATION, OF EQUIPMENT AND ALL ASSOCIATED WIRING VOLTAGE OPERATIONAL RANGE. AND INTERCONNECTIONS SHALL BE PERFORMED ONLY BY - QUALIFIED PERSONS (CEC 690.4) - OUTDOOR EQUIPMENT SHALL BE NEMA -3R RATED OR BETTER + - ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND - - ANCHOR CONDUIT RUNS AS REQUIRED PER NEC. - ALL WIRING MUST BE PROPERLY SUPPOTED-BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH. USE, AND FOR ROOF -MOUNTED SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELD. OFF OF ' . THE ROOF SURFACE. NEC 110.2 - 110A/ 300.4 - ALL PV,METERS TO. BE WITHIN 5 FT OF ANOTHER. - r - PV METERS TO BE INSTALLED CORRECTLY, SUPPLIED FROM THE TOP JAWS. ' ALL ROOF PENETRATIONS MUST BE FLASHED. SIMPLY CAULKING DOES NOT• .SUFFICE. ' • `3760 MORROW LANE SUITE D - CHICO, CA 95928 - 1(855)360 -JOIN LIC #: 1021484 60 ELITE DR CHICO, CA 95973 CLIENT PHONE # 530-519-9555 JURISDICTION: CITY OF CHICO UTILITY: PG&E TABLE OF CONTENTS P-1 COVER SHEET P•2 SITE:PLAN P.3 MODULE LAYOUT P.4 MOUNTING DETAILS P.5 ELETRICAL SCHEMATIC P.6 ELETRICAL NOTES P.7 STICKER / P_LACECARD%c.: I I I f ;t 11 p 71 I WARNING: ELECTRIC SHOCK HAZARD WARNING MAIN PHOTOVOLTAIC SYSTEM AC DISCONNECT ,� ELECTRIC SHOCK HAZARb � • _ � • DO NOT TOUCH TERMINALS IF GROUNDEDAUL FT IS INDICA►TED TERMINALS ON BOTH THE LINE AND LOAD NORMALLY GROUNDED CONDUCTORS SIDE MY BE ENERGIZED IN THE OPEN ' • • • NNECT MAY BE UNGROUNDED AND ENERGIZED POSITION PLACED ON �OR ADJACENT TO THE 't j PLACED OWTHE]NVERTER.'ORPLACED • • - - WARNING / RAPID SHUTDOWN SWITCH FOR r SOLAR PV SRSTEM OVERCURRENT AT A -VISIBLE LOCATION UTPUT�CONNECTION 41tDO NOT RELOCATE THIS OVER CURRENT DEVICE PLACED . THE.SOLARBREA5.711 KER PHOT©VOLT��IC DISCONNECT'% PLACED ON OR ADJACENT TO•THE r . _DISCONNECTING MEANS . a_ „ LOGATED'ON THE DC DISCONNECT e e D D I MHE,TOVOLTAIC SYSTEM L�1LAR RELOCA OVERCURRENT ��� AC DISCONNECT �� OPERATING VOLTAGE ®VOLTS OPERATING CURRENT AMPS PORTION OF THE INVERTER _ Ukgfil RM UH 1° r. RW­ jRNINELECTRIBRECKFED - 60 ELITE DR TABLE OF CONTENTS ` ' CHICO,,CA 95973 P.1 COVER SHEET_ ° CLIENT.PHONE,# P.2. 'SITE PLAN'. 530-519-9555 P.3 MODULE LAYOUT -"STICKERS-AND PLACECARDS M 3760 MORROW LANE SUITE D. JURISDICTION: PA MOUNTING DETAILS 4' CHICO, CA 95928. • CITY OF CHICO P.5 ELETRICAL SCHEMATIC F ` 1(855)360 -JOIN _ UTILITY: P.6 ELETRICAL NOTES ' LIC # : 1021484 - PG&E:1P.71 STICKER/ PLACECARDS BREANOT L�1LAR RELOCA OVERCURRENT DEVICE ?. RW­ jRNINELECTRIBRECKFED - 60 ELITE DR TABLE OF CONTENTS ` ' CHICO,,CA 95973 P.1 COVER SHEET_ ° CLIENT.PHONE,# P.2. 'SITE PLAN'. 530-519-9555 P.3 MODULE LAYOUT -"STICKERS-AND PLACECARDS M 3760 MORROW LANE SUITE D. JURISDICTION: PA MOUNTING DETAILS 4' CHICO, CA 95928. • CITY OF CHICO P.5 ELETRICAL SCHEMATIC F ` 1(855)360 -JOIN _ UTILITY: P.6 ELETRICAL NOTES ' LIC # : 1021484 - PG&E:1P.71 STICKER/ PLACECARDS