Loading...
HomeMy WebLinkAboutB17-1544 000-000-000FCX Compa4y 3995 Olive Highway, OraviIICa Ca_ 95966 530-533-2730-. / 530-534-=-1608 ( Fax } Ca_Lic_ 305365 C-10, C-16, C-36 Residential Fire Sprinkler System Component List` wo 4 _ WATER TEST GUAGE. 5 _ 2 PULE FLOW SW I TCH BUTTE COUNTY JUL 27.:2017 6.- ALARM ,BELL DEVELOPMENT SERVICES R17- )S yL) PERMIT # BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR COD C MPLIA E . DATE BY GOMp,� .�O Y * G16 CALIFORNIA LI' NSE N 5 CTIMA �� ` RESIDENTIAL FIRE SPRINKLER SYSTEM DESIGN BY FOX COMPANY C-16. LIC. # 305365',;� PER REQUIREMENTS OF NFPA 13D-2016 EDITION s w------ -_ __--_ _ _ __--_ ______________ JIM BLACK CONST. BLACK HOME .' P.O.BOX 636 MARSH CT. AP039-460-082 DURHAM CA. 95938 DURHAM PLAN NUMBER 3129 7/26/17 WATER SOURCE IS PUBLIC UTILITY WATER PRESSURE IN STREET 60 DEDUCT METER LOSS FOR SIZE 1'' — 3 57 DEDUCT PRESSURE LOSS FROM SOURCE TO SPRINKLER CONTROL VALVE MAIN SECTION EQUIV.FT. 1--1/4" PIPE = 35 FT. 1 GATE VALVE = 2 FT. 1 CHECK VALVE — 5. FT. 3 90 ELBOWS — 18 FT. 2 COUPLINGS = 2 FT. 1 TEES (RUN) = 1 FT. 0 TEES (BRANCH) = 0 FT.. TOTALS = 63 FT. X .0343 — 2.16 DEDUCT HEAD LOSS FOR ELEVATION . ( 14 FT. X 0-434 . ) . -- 6.08 DEDUCT PRESSURE LOSS FOR PIPING FROM CONTROL VALVE TO FARTHEST SPRINKLER 54.84 48. 7.6 PIPE SECTION ONE EQUIV.FT. 1'' PIPE = 165 FT.. 9'0�"ELBO:W:a.^ 1 CROSSES = 1 FT. 17 TEE(RUN) & 45 ELL = 17 FT. 1 TEES (BRANCH) — 5 FT. TOTALS = 218 FT. X .1067 -23.26 25.50 BRAND OF HEADS.= GLOBE 4906 K FACTOR OF HEADS USED = 4.9 EQUIVALENT FEET CALCULATED @ 2 HEAD 2 HEAD = 26 G.P.M. FLOW ( 13 G.P.M. EA.) FRICTION LOSS `C' FACTOR = .150 G.P.M. — P.S.I. CONVERSION FORMULA. MINIMUM PRESSURE REQ'D. FOR SPRINKLER HEAD(S) DOMESTIC LOAD OF 5 G.P.M. 1.25 IN. PIPE = 35 FT. @ 5 G.P.M. (G.P.M./ K.FACTOR)2 = P.S.I. 7.04 P.S.I. — 0.06 P.S.I. TOTAL.PRESSURE REQ'D. 7.09 P.S.I. PRESSURE AVAILABLE IN SYSTEM = 25.50 P.S.I. 3995 Olive Highway Oroville,.CA 95966 � Phone (530) 533-2730 FOX COMPANY''. Lic. No. 305365 "OW THE I=rRL SF)'RXNKLE7R SYSTEiN c7F�'E7RA-r S UTILITY DISTRICT WATER SUPPLY: The zy.a.tem activa.te.-a the 4.ine .apn.inkten.a whenever: A) The FLOW SWITCH .aen.ae.a wate.n 6tow .in the .ay.atem e..ithen by a head '6i4.ing' o44, on .the INSPECTOR TEST VALVE being opened to ztmu.tate a head 4.in.ing o44. The .ayatem can be SHUT DOWN by .tunn.ing OFF the CONTROL VALVE at the bate o4 the FIRE RISER. TEST & FLUSH -SYSTEM: ---- -- The �napee on teak vatve .ahoutd be opened .MONTHLY' to t.e-6t and .6tu-zh the .ay-a.tem, ' activate a.e:anm belt and .smoke a.tanm.a. A .two to three minute water 4tow ,tee t .ahoutd be .au44.ic.ient .to teat att openat ions . o4 the zy4 tem "THE INCH" GL6.) RESIDENTIAL ' •AUTOMATIC SPRINKLERS FIRE SPRIN c ER CORPORATION MODEL GL4906' ONE INCH ADJUSTABLE FLAT PLATE CONCEALED PENDENT DESCRIPTION AND OPERATION. The Globe Model GL4906 Residential One Inch Adjustable Concealed Pendent Sprinkler has a ` flat plate profile that utilizes a 3mm frangible glass ampule as the thermosensitive element. Itfeatures economy, aesthetics and the lowest allowable water flow with a nominal 1"of adjustment for easier installation. The combination of the 3mm frangible glass ampule and specially designed deflector make the Model GL4906 the ultimate in life safety and fire control. It has met the strict requirements of Underwriters Laboratories Inc. as described in UL Standard, 1626; for Residential Sprinklers for Fire Protection Service, and should be used accordingly. This sprinkler should also be installed in accordance with the appropriate NFPA Standard 13, 13D or 13R and under the direction of the i approving authorities having jurisdiction. ' - All that is seen at the ceiling is the 3 5/16" diameter flat ceiling plate color finished to match the • specifier's exact requirements. The ceiling plate is soldered to the sprinkler's special uppersupport assembly in three places. Upon the application of sufficient heat, the plate falls to the floor exposing the residential pendent spray sprinkler. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass bulb to shatter. This results in water discharge which is distributed in an approved pattern. TECHNICAL DATA • See reverse side for Approvals and Specifications. • Temperature Rating: 155°F (68°C) . Water Working Pressure Rating: 175 psi (12 Bars) • Factory tested hydrostatically to 500 psi (34 Bars) • Maximum lowtemperature glass bulb rating: -67°F (-55°C) • Frame = bronze • Deflector -'brass Screw - brass • Bulb seat - copper • Spring - nickel alloy • Seal - teflon • Bulb - glass with alcohol based solution, 3mm size • Cover Plate - brass ` • Upper Escutcheon Assembly- steel RESIDENTIAL FLAT PLATE CONCEALEDPENDENT • SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER BULB COLOR TEMPERATURES N.F.P.A. MAXIMUM CEILING TEMPERATURE ORDINARY 1;5 68C RED, .� 'ti, Od 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 t SEPTEMBER 2011 A-10 ,. ."V . . 4 989-846-4583 FAX 989-846-9231 ' BULLETIN GL4906, REV. #1 . RESIDENTIAL AUTOMATIC SPRINKLERS MODEL GL4906 ONE INCH ADJUSTABLE FLAT PLATE CONCEALED PENDENT SPECIFICATIONS AND- APPROVALS SIN NOMINAL GL4906 12'x 12' 13 G.P.M. - 7 P.S.I. 14'x 14' 13 G.P.M. - 7 P.S.I. 155°F (68°C) 18'x 18' 17 G.P.M. - 12 P.S.I. 20'x 20' 20 G.P.M. - 16.7 P.S.I. THREAD SIZE LENGTH FINISHES SPRINKLER WITH cULus MODEL. "K" FACTOR 135°F 57°C PLATE Bright Chrome White Painted GL4906 4.9 (68 metric) 1/2" NPT 3" (7.6 cm) Bright Brass' X X Satin Chrome.' Other Painted Finishes' NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'FINISHES AVAILABLE ON SPECIAL ORDER. FOR PAINTED PLATES OTHER THAN WHITE, CONTACT GLOBE FOR ORDERING SPECIFICATIONS. INSTALLATION DATA FOR FLAT AND SLOPED CEILINGS" ONE INCH ADJUSTABLE FLAT PLATE CONCEALED PENDENT MODEL MAXIMUM AREA OF IMINIMUM WATER DISCHARGE & COVERAGE PRESSURES NEEDED PER SPRINKLER* GL4906 12'x 12' 13 G.P.M. - 7 P.S.I. 14'x 14' 13 G.P.M. - 7 P.S.I. 16'x 16' 13 G.P.M. - 7 P.S.I. 18'x 18' 17 G.P.M. - 12 P.S.I. 20'x 20' 20 G.P.M. - 16.7 P.S.I. NOTE: MINIMUM 9' SPRINKLER SPACING. 'WHEN THESE SPRINKLERS ARE USED IN NFPA 13 SYSTEMS, A 0.1 DESIGN DENSITY MINIMUM SHALL BE UTILIZED. "REFER TO PAGE 2 OF THE GLOBE RESIDENTIAL SPRINKLER INSTALLATION GUIDE FOR NFPA 13D and 13R REQUIREMENTS. ORDERING INFORMATION CROSS SECTION SPECIFY 2 3/4" DIA. MIN. • Quantity • Model Number • Style HOLE IN CEILING ._ •Orifice • Temperature • Finishes desired —2 3/8" DIa--.{ . Quantity - Concealed Wrenches - P/N 332765 • Quantity - Protective Caps - P/N 332868 DEFLECTOR DROP PIN 2 3/4' MAX. ® ® 1 7/8" MIN. SUPPORT SHELLS I CEILING COVER PLATES FLATPLATE CONCEALEDPENDENT GL698Z, FIR.ESPRINKLER CORPORATION SEPTEMBER 2011 COVER PLATE SIZE WHITE 135'F PART # CHROME 135°F PART # 3 5/16" 332892 332891 GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manu- factured products found to be defective in material or workmanship for a period of one year from date of ship- ment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkler.com PRINTED U.S.A. BULLETIN GL4906, REV.#1 FIRE SPRINKLER CORPOR T10N DESCRIPTION AND OPERATION A/--/ -iC. � QUICK RESPONSE A_ UTOMATIC SPRINKLERS GL SERIES UPRIGHT • PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the'thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offersthe additional feature of greatly increased safety to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design requirements. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. TECHNICAL DATA QUICK RESPONSE PENDENT VERTICAL •See reverse side for Approvals and Specifications. SIDEWALL •Temperature Ratings - 135°F (570C), 155°F (680C), 175°F (790C), 200°F (93°C), 286°F (141-C) • Water Working Pressure Rating - 175 psi (12 Bars) • Factory tested hydrostatically to 500 psi (34 Bars) �nk • Maximum low temperature glass bulb rating is -67°F (-55°C) QUICK RESPONSE • Frame - bronze • Deflector - brass • Screw - brass HORIZONTAL LPC/CE • Lodgement Wire - stainless steel • SIDEWALL HORIZONTAL • Bulb seat - copper • Spring - nickel alloy • Seal - teflon SIDEWALL • Bulb - glass with alcohol based solution, 3mm size •SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING 4077AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 • FAX 989-846-9231 JULY 2012 A-20 BULLETIN GI -5615, REV. #9 CLASSIFICATION AVAILABLE SPRINKLER BULB COLOR N.F.P.A. MAXIMUM TEMPERATURES CEILING TEMPERATURE ORDINARY 135°F1(55°F+ `' '57°C/6$°C ORANGE/RED 10p°F 38°C'. INTERMEDIATE :175°F'1200°F 79°C/63°C YELLOW/GREEN 150°F HIGH ,;. v286°F' ... >; 141°C_: <' BLUEi 4077AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 • FAX 989-846-9231 JULY 2012 A-20 BULLETIN GI -5615, REV. #9 QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT. PENDENT o VERTICAL SIDEWALL HORIZONTAL SIDEWALL • CONVENTIONAL (OLD STYLE SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH' FINISHES 2.8 (39 metric) 1/2" NPT 2 1/4" (5.7cm) 200T 286°F cUlus FM Factory Bronze 4.2 (59 metric) 1/2" NPT 2 1/4" (5.7cm) MODEL FACTOR 57°C Chrome 5.6 (80 metric) 1/2" NPT 2 1/4" (5.7cm) White Polyester 3 7.8 (111 metric) 1/2" NPT 2 1/4" (5.7cm) LH X X X Black Polyester 23 8.1 (116 metric) 3/4" NPT 2 7/16" (6.2cm) — METRIC CONVERSIONS ARE APPROXIMATE. 'HORIZONTAL SIDEWALL IS 2 9/16". 'FINISHES AVAILABLE ON SPECIAL ORDER. 3 AVAILABLE AS cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. APPROVALS STYLE SIN K HAZARD' 135T 155T 175T 200T 286°F cUlus FM LPC CE NYC - DOB MODEL FACTOR 57°C 68°C 79°C 93°C 141°C MEA 101-92-E GL2815 2.8 LH X X X X X X — — — X QL4215 4.2 LH X X X X X X — — — X GL5615 5.6 UPRIGHT LH/OH X X X X X X X X X X GL8115 7.8• LH/OH X X X X X X — — — X GL8118 8.1 LH/OH X X X X X X X X X X GL2801 2.8 LH X X X X X X — — — X GI -420i 4.2 LH X X X X X X — — — X PENDENT GL5601 5.6 LH/OH X X X X X X X X X X GL8101 7.8• LH/OH X X X X X X X — — X GL8106 8.1 LH/OH X X X X X X X X X X VERTICAL GL5632 5.6 LH X X X X X X X — — — SIDEWALLt GL8133 8.1 LH X X X X X X — — — — GL2826 § 2.8 LH X X X X X X — — — X GL4226 § 4.2 LH X X X X X X — — — X HORIZONTAL GL5626 § 5.6 LH/OH X X X X X X X — — X SIDEWALL GL562713 5.6 LH/OH X X X X X — — X X — GL8127 § 8.1 LH/OH X X X X X X — — — — CONVENTIONAL- GL5624 5.6 LH/OH X X X X X — — X X — (OLD STYLE) 61-8125 8.1 LHIOH X X X X X — - X X — • 1SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS. §HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6" BELOW THE CEILING. °INSTALL IN ACCORDANCE TO BS5306 AND ANY OTHER RELATED DOCUMENTS. ?PENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. tUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR T MIN. SPACING. OR ORDINARY HAZARD LH: LIGHT HAZARD •1/2" NPT ORDERING INFORMATION GLOBE° PRODUCT WARRANTY SPECIFY - • Quantity • Model Number • Style Globe agrees to repair or replace any of its own manufactured • Orifice • Thread Sizes Temperature products found to be defective in material or workmanship for a • Finishes desired period of one year from date of shipment. • Quantity - Wrenches - P/N 325390 (1/2"); For specific details of our warranty please refer to, Price List P/N 312366 (L.O.) Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 av,.. 989-846-4583 FAX 989-846-9231 �RJE ���`ER � ORNPATION 1-800-248-0278 www.globesprinkler.com JUNE2012 PRINTED U.S.A. BULLETIN GL5615, REV. #9 a } smell f W J Q N Z O M M Bronze Spring Loaded Check Valve %"-2" Figure No. 3600 w/Teflon Disc. Figure No. 3600SJ w/Teflon Disc Figure No. 3615 w/Buna-N Disc Figure No. 361'5SJ w/Buna-N Disc 125 PSI Saturated Steam, with TFE Disc Buna-N Disc Rated at 250 PSI 250 PSI Non -Shock Cold Water, 011, or Gas Fluid Pressure, Non -Shock W.O.G. lure No. 3600 lure No. 3615 Threaded Grinnell check valves may be Installed in vertical lines with upward flow or In any intermediate position. Do Not Use For Reciprocating Air Compressor Service. Do Not Use as a Footvalve. Q) Figure No. 3600SJ Figure No."3615SJ Copper to.Copper M Met I Ad 25 !r'n.;�yt3h:w.}E`,�a�. ��i'�•'�;+: K�. �r4��yy`..���.j1 '• L��./Mr{Ya�CY.� I.,JC,•'-�.. .'� �4Y _ _ �. � .... �k.Sf\�";1N::� � -iv � .. .�� t � `hni �.. +'b��Ld'��•Ya;" �.,'1:i; t:%� .�'.. .. t)IFnen§toils — Weights Nominal Size Part Speciilcation 1. Body -Bronze ASTM B-584 Alloy C84400 2. Stem Stainless Steel ASTM A-582 Alloy S30300 . 3. Spring 316 Stainless Steel 4. Disc Holder Stainless Steel Type 301 S. Disc Teflon, Fig. 3600 5A. Disc Buna-N, Fig. 3615 6. Seat Ring Teflon 7. 8. Seat Screw Body End Stainless Steel ASTM A-276 Alloy S43000 Bronze ASTM B-584 Alloy C84400 Nominal Size DimensionsApprox. wt. Fig. Approx. Net Fig.et q g C 2b 2 11/8 17/16, .4 4 1/2 21116 13/e 13/16 .4 .4 2/4 21/4 15/s 15/16 .5 .5 1 25/6 2 11/2 .8 .9 11/4 215/16 2'/6 111/t6 1.2 1.3 1112 35h r, 23/4 2 1.6 1.9 2 33/4 33/6 25/16 2.4 2.7 no ��1°iCflr.T#W1MmL1NE,, cant dw 1 800 854-1015 FIRE SPRINKLER pRESSURE-GAUGES U.S. GUAG 8, AMETEK • Use on wet or dry sprinkler systems! • Solid brass backed! tioo 2Qo , '/," A .NTP -LM brass fitting; 31/2 diameter YS ''i M • 300 lb./sq. In. Capacity 25 0 ins qua' Sao &OSTED r APPROVE VS -SF (0)POTTER VANE TYPE WATERFLOW e POR SMALL PIPE ALARM SWITCH WITH RETARD Potter EleatNa signal Company potter Electric Signal & Mfg. LTD 2081 Craig Road • P.O. Box 28480 1967 Leslie Street St. Louis, MO 63146.4161 Don Mills, Ontario, Canada M362116113 (314) 8784321 • (800) 325.3936 (416) 441-1833 STK. NO'. 1113000 U.S. PAT. NO. 3921989, CANADIAN PAT, NO -j009680 UL, ULC, CSFM LISTED and NYMEA ACCEPTED Service Pressure: Up to 250 PSI Minimum Flow Rab for Alarm: 10 OPM Maximum Surge: 18 FPS Enclosure: DI"ast, red enamel finish. Cover hell In piece wtM tamper resistant screws Contact Ratings: Two seta of SPDT (Form C) 16.0 Amps at 123/250 VAC 2.0 Amps at 0.30 VDC Conduit Entrances: Two Knockoute provided for 112' condult U409s. Listed Plastic, Copper and Schedule 40 Iron Pipe Fits pipe sizes- 1', 1 1/41, and 1 1/2' Note: a paddles are furnished with each unit one for each pipe size of threaded or sweat TEE, one for i' CPVC, and one for 1 1/2' polybutylene (CTS -Copper tubing size) Environnwrttal Specifications: - Suitable for Indoor or outdoor use with factory metalled gasket and die-oW housing : = NEMA 4 Rated Enclosure • use with appropriate conduit. Ailing Temperature Range: 400 F/120° F (4.54 C/4W C) :- _ Caution: This device Is not Intended for applicall" In exploetve environments Service Use: - Automatic Sprinkler NFPA-13 One of two family dwelling NFPA-13D Resldentlal occupancy up to four stories - NFPA-13R Nstionat Fire Alarm Code NFPA42 r ::...; OTHER PATENTS PENDING. Y~. ; I,:. optional: Cover Temper Swt6eh, order Suc. No. 000o 91B The Model VSFI.SF is a vane type waterflow switch for use on waf sprinkler The vane must not rub the Inside of the TEE or bind In any way. The stern systems that use 11,J 1/4', or 1 1/2' pipe size. The unit may also be used should move treaty When operated by hand. as a sectional watidlow detector on large systems. The unit contains two single pole double throw anap aollon switches and an adfustabke pneumatic retard. The switches are actuated when a HOW Of _t O.pellone per minute or. more occurs downstream of the doviat. The }IoW condition must exist for a pariod of time necessary to' overoome the selected retard period. I t INSTALLATION: These devices may be mounted In hcrtzontsl or veftW pipe. On horizontal pipe they should be Installed on the top side of the pipe" where they vAl be accessible. The units should not be Installed within fl' of a valve, draln or fthing which changes the direction of the wsterflow. The unit has a 1' NPT bushing for threading Into a noncorrosive TEE. gee Fig, 2 for proper TEE size, type and Installation. Screwthe device Into the TEE fitting as shown In FIg.2. Cars mustbetaken to properly orient the device for the direction of waterflow. The dsvtoe can also be used In copper or plastic pipe InstWtlons with the proper adapters so that the specified TEE Atttnp may be Installed on the pipe run. INSPECTION AND TESTINO: Check the operation of the unit by opening the Inapeetor' teat valve at the end of the sprinkler fine or the drain and test oonneetlon, ti an Inspector's test valve Is not provided. If there are no provisions for testing the operation of the flow detection device on the system, appiklatton of the VSR-9F Is not recomr wride8 or 'advisable The frequancy, of the Inspection and testing and tts associated protective mon{tor" eyatam should be In nccardanoe With the applicable NFPA Codec and Standards and/or authortty having jurisdiction (rWufaoturer recommends quarterly or more frequently). CAUTION: There are 8 paddles fumished with each unit. These paddles have raised lettering that shows the pipe size and type of TEE that they are to be used with. The proper paddle MUEf be used, The screw that holds the paddle must be securely tightened. MKT. !l8000QJ • REV I PAt3E 1 CV 2 PRINTED IN USA MFG. #9400M , 3/06 BELLS ®PTT PBA -AC &PB D_ DC Potter Electric Signal Company Potter Electric Signal 8t Mfg. LTD 2081 Craig Rd.,/P.O. Box 28480 1967 Leslie Street St. Louis, MO 63146 Don Mills, Ontario, Canada M31B2M3 (314)878-4321 / (800) 325-3936 (416) 441-1833 UL LISTED, FM APPROVED - Sizes Available: 6", 8", and 10" • Voltages Available: 24VAC 120VAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31:2) Polarized -'Service Use: Fire Alarm General Signaling Burglar Alarm Environment: Indoor or Outdoor Use (See Note 1) -400 to 150°F (outdoor use require -,weatherproof backbox) Termination: 4 No. 18 AWG stranded wires Finish: Red powder coating 6" BELL SHOWN Optional: 'Model BBK-1 weatherproof backbox These vibrating type bells are designed for use as fire, burglar, or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4". square electrical box for,indoor use, or on a model BBK-1 weatherproof backbox for outdoor -applications.. =` ALL DC BELLS ARE POLARIZED AND HAVE BUILT-IN TRANSIENT PROTECTION: SIZE VOLTAGE MODEL NO. STOCK NO. CURRENT (MAX) TYPICAL dB 10 FT. MINIMUM dB . ®10 FT.' 6 12VDC PBD126 1706012 .12A 85 75 8 12VDC PBD128 1708012 .12A 90 75 10 12VDC PBD1210 1710012 .12A 92 75 ' 6 24VDC PBD246 1706024 .06A 87 75 8 24VDC PBD248 1708024 MA 91 79 10 24VDC PBD2410 1710024 MA 94 79 6 24VAC PBA246 1806024 .17A 91 75 8 24VAC PBA248 1808024 .17A 94 75 10 24VAC PBA2410 1810024 .17A 94 75 6 120VAC PBA1206 1806120 .05A 92 82 8 120VAC PBA1208 1808120 .05A 99 82 10 120VAC PBA12010 1810120 .05A 99 85 Weatherproof backbox model BBK-1 Stk. No. 1500001. Notes: 1. Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is •30° to 150°F. 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. PRINTED IN USA MKT. #8850001- REV K PAGE 1 OF 2 MFG. #5400776 - 4/94 9600 KLINGERMAN STREET * P.O. BOX 3365 O SOUTH EL MONTE, CA 91733 * USA TEL: 626.444.0541 * FAX: 626.444.3887 i E-MAIL: info@afcon.org * www.afcon.org )us CPUC - STEEL - COPPER ' #510 #511 #514 0 o 10 Patented 0 1 s - Installation Instructions Install on CPUC pipe as a hanger and/or restrainer -. -- per thea- encyineerino.sheets. Some are additionally " listed for use for use with steel and copper pipe. #510 & #514 install on top, bottom or side ' of beam. #511 install on top or bottom of beam. - #513 install on top or side of beam. #515 & 519 install on side of beam. ' Required fasteners furnished: #904 for #515 CAV.C. - Max. Hanger #905 for #510 thru #514 Pipe Size Spacing 3/4 ------ ------- 5 1/2 -------------- - 6 ' 1 1/4 ------------- 6 1/2 1 1!2 ------- ------ 7 2 --------- ---- 8 z -------------- 10