HomeMy WebLinkAboutB17-1977 030-038-010i •
DEVELOPMENT SERVICES
BUTTE COUNTY
DEPARTMENT OF DEVELOPMENT SERVICES
INSPECTION CARD MUST BE ON JOB SITE
24 Hour Inspection Line (IVR) : 530.538.4365 (Cut off time for inspectioes is 3pm)
Development Services cannot guarantee inspections on the date re-Iuested
Office: 530.538.7601 Fax: 530.538.7785 www.ButteCounty.net/dds
Permit No: B 17-1977. Issued: 8/29/2017
APN: 030-038-010
Address: 48 VISTA ESTATES COURT, OROVILLE
Owner: LANE, LARRY
Permit Type:. SOLAR ROOF -RES
Description: Install 4.14kw roof mount to existing meter
AREA
1
Flood Zone: AE SRA Area: No
,SETBACKS for Zn-ninv- AG- SR -'PW
Front: Centerline of Road:
Rear: SRA:
Street: AG:
Interior
Total Setback from Centerline of Road:
ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING
Inspection Tyve
IVR INSP . DATE
Setbacks
131
Foundations / Footings
111
Pier/Column Footings
122
Eufer Ground
216
Masonry Grout
120
Setbacks
131
Do Not Pour Concrete Until Above are Signed
Pre -Slab
124
Gas Test Underground/floor
404
Gas Piping Underground/floor
403
Underfloor Framing
149
Underfloor Ducts
319
Shear Transfer
136.
Under Floor Plumbin
412
Under Slab Plumbing
411
Blockin nd_e" inin
612
Tiedown/Soft Set System
611
Do Not Install Floor Sheathing
or Slab Until Above Signed
Shearwall/B.W.P.-Interior
134
Shearwall/B.W.P.-Exterior
135
Roof Nail/Drag Trusses
129
Manometer Test
605
Do Not Install Siding/Stucco or Roofing Until Above Signed
Rough Framing
153
Rough Plumbing
406
Rough Mechanical
316
Rough Electrical
208
4 -Way Rough Framing
128
Gas Piping House
403
Gas Test House
404
Shower Pan/Tub Test
408
Do Not Insulate Until Above Signed
Permit Final
802
Electrical Final
803
Mechanical Final
809
Plumbing Final
813
Fire Sprinkler Test or Final
702
Swimm-Ing
Pools
Inspection Type
IVR INSP DATE
T -Bar Ceiling
145
Stucco Lath
142
Swimm-Ing
Pools
Setbacks
131
Pool Plumbing Test
504
Gas Test
404
Pre-Gunite
506
Pre -Deck
505
Pool Fencing/Alarms/Barriers �j
503
Pre -Plaster
507
Manufactured Homes
Setbacks
131
Blockin nd_e" inin
612
Tiedown/Soft Set System
611
Permanent Foundation System.
613
Underground Electric
218
Sewer
407
Underground Water
417
Manometer Test
605
Continuitv Test
602
Skirting/Steps/Landings
610
Coach
Info
Manufactures Name:
Date of Manufacture:
Model Name/Number:
Serial Numbers:
Length x Width:
Insignia:
Finals,
Public Works Final 538.7681
Fire De artment/CDF 538.6226
Env. Health Final 538.7281
Sewer District Final
"PROJECT FINAL °1 t4'17
rrolect rLnaL is a %-ernncaL-- oT occupancy for kxesLoennaL unry)
PERMITS BECOME NULL AND VOID 1 YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A 1 YEAR
RENEWAL 30 DAYS PRIOR TO EXPIRATION.
PROJECT OWNER:
LANE, LARRY & CAROL
48 VISTA ESTATES COURT
OROVILLE , CA 95965
APN:030.038.010 PH#:530.520.6997
EMAIL:Iarry@kingdomc.org
CONTRACTOR:
ALTERNATIVE ENERGY SYSTEMS INC.
13620 HIGHWAY 99
CHICO, CA 95973
CSLB: 853351 C-10, C-46
BUILDING JURISDICTION:
BUTTE COUNTY
DEPT. OF DEVELOPMENT SERVICES
7 COUNTY CENTER DRIVE
OROVILLE, CA 95965
OFFICE#: (530) 538-7601
FAX#: (530) 538-2140
MON-FRI 8AM-3PM
INSPECTION LINE: (530) 538-4365
REQUESTS PHONED IN BY 2PM WILL BE
INSPECTED THE NEXT BUSINESS DAY
L...qc co
SCOPE:
INSTALL PHOTOVOLTAIC SOLAR SYSTEM ON A TRUSS
ROOF, MOUNTED IN ACCORDANCE WITH ALL
APPLICABLE BUILDING CODES SPECIFICALLY
REFERENCING THE 2016 CALIFORNIA ELECTRICAL
CODE/ 2014 NEC USING THE FOLLOWING SPECIFIC
EQUIPMENT.-
1.
QUIPMENT:1. MODULES: SUNPOWER
(12) SPR -X21 -345 -C -AC
4.14kW SYSTEM
219 SQFT COVERED
2. INVERTER(S): SUNPOWER
(12) MODULE INTEGRATED 320W
SITE MAP
PAGE # CONTENT
PV -1.0
SCOPE
PV -2.0
SITE PLAN
PV -3.0
ARRAY LAYOUT
PV -4.0
ELECTRICAL DIAGRAM
PV -4.1
LABEL DIAGRAM.
PV -5.0
GENERAL NOTES
ATTACHMENT
MODULE SPECS .
INVERTER SPECS
o
RACKING SPECS
48 VISTA ESTATES COURT
WIRE CALCS '
A
�
o
9
o
m
�,
°
a
m
. g
LANE, LARRY & CAROL ,
13620 H 99
Energy for Life
9y. CHICO,CA95973
m
<_
LA
o C
p p
o
;
48 VISTA ESTATES COURT
PHONE#: (530) 345-6980
z
_
OROVILLE , CA 95965
��® FAX#: (530) 892-2360
°8
APN:030.038.010 PH#:530.520.6997
Alternative Energy Systems Inc. design@solarenergyforlife.com
r�
..�. a ., s. � �•+ r • .. V - _ . - i` � �.
a1 (E) RESIDENCE
(E) COMPOSITION ROOF
W/ WOOD TRUSSES T
MONITORING INSIDE GARAGE
{ _ — —
R'�/ • � (E) PGCE METER
(E) SERVICE PANEL
.+ •
^o
oZ°
= m
n�
�3�
S
LARRY &CAROL
13620 HWY 99
"{RICO,CA9973•EnergyForUf'
4LANE,
<
mz •'N , n
_
^:E�Zp
48VISTA ESTATES COURT
PHONE#: (530) 345-6980m
o?
'
�-
OROVILLE CA 95965
APN:030.038.010-PH#:530.520.6997'
`'� '
Alternative Energy Systems Inc.,
-2360-n FAX#: (530) 892. e
design@solarenergyforlifexom
t
••
f - .. V
• 'RL • P Y Y "',^
v Y. ' • 1�''
J .. ' ' it � ..'' �.
-------------
6'-011 _
-' J •ATTACHMENTS MAX 6' ON CENTER
RAFTERS 24" ON CENTER
< LEGEND ;
e DIRECT-.
5' PR .
10' PR
3' pp ♦�
* ' , 10' PP—�
6' RR
1 10' RR Q�
- NOTES RECEPTICAL END CAP
1.ALL ROOF PENETRATIONS PLUG END CAP 0
` TO BE 72" O.C.'MAXIMUM • 'PARALLELE CONNECTION 0
ARRAY LAYOUT
n ^o a S LANE, LARRY &CAROL 13620 HWY 99
m ` .
9 m :. . Energy ForLffe t
' _ o m CHICO, CA 95973 r ..
< 1 a a poo" m 48 VISTA ESTATES COURT
,ma_y .. o$ • OW %=p ^D �bm • PHONEi: (530) 345-6980
FAX#: (530) 892-2360_ OROVILLE,CA95965 Alternative Energy Systems Inc 'p
APN:030.038.010 PH#:530.520.6997 d6sign@s'ola-renergyforlife.com
„.
z
�.
■ e
D
ul
0 e 0
■
i
FIRE CODE f ..
10" _ T
'�
t
61_1111 ,
;rE.
O
-------------
6'-011 _
-' J •ATTACHMENTS MAX 6' ON CENTER
RAFTERS 24" ON CENTER
< LEGEND ;
e DIRECT-.
5' PR .
10' PR
3' pp ♦�
* ' , 10' PP—�
6' RR
1 10' RR Q�
- NOTES RECEPTICAL END CAP
1.ALL ROOF PENETRATIONS PLUG END CAP 0
` TO BE 72" O.C.'MAXIMUM • 'PARALLELE CONNECTION 0
ARRAY LAYOUT
n ^o a S LANE, LARRY &CAROL 13620 HWY 99
m ` .
9 m :. . Energy ForLffe t
' _ o m CHICO, CA 95973 r ..
< 1 a a poo" m 48 VISTA ESTATES COURT
,ma_y .. o$ • OW %=p ^D �bm • PHONEi: (530) 345-6980
FAX#: (530) 892-2360_ OROVILLE,CA95965 Alternative Energy Systems Inc 'p
APN:030.038.010 PH#:530.520.6997 d6sign@s'ola-renergyforlife.com
„.
z
�.
■ e
D
ul
0 e 0
■
-------------
6'-011 _
-' J •ATTACHMENTS MAX 6' ON CENTER
RAFTERS 24" ON CENTER
< LEGEND ;
e DIRECT-.
5' PR .
10' PR
3' pp ♦�
* ' , 10' PP—�
6' RR
1 10' RR Q�
- NOTES RECEPTICAL END CAP
1.ALL ROOF PENETRATIONS PLUG END CAP 0
` TO BE 72" O.C.'MAXIMUM • 'PARALLELE CONNECTION 0
ARRAY LAYOUT
n ^o a S LANE, LARRY &CAROL 13620 HWY 99
m ` .
9 m :. . Energy ForLffe t
' _ o m CHICO, CA 95973 r ..
< 1 a a poo" m 48 VISTA ESTATES COURT
,ma_y .. o$ • OW %=p ^D �bm • PHONEi: (530) 345-6980
FAX#: (530) 892-2360_ OROVILLE,CA95965 Alternative Energy Systems Inc 'p
APN:030.038.010 PH#:530.520.6997 d6sign@s'ola-renergyforlife.com
„.
z
�.
I
I
I
-I
I
I
AC -1
ON ROOF w/
(2) TRANSITION CABLE
�nnoc of iu• c
AC -1
SERVICE VOLTAGE
20 = 2= 40
120V=N-L2-L3=NAV
NAV=N-L3-LI=NAV ,
ELECTRICAL DIAGRAM
D m
a=
-0
<
mo
Z
m
Z
p
o
n
3
S
m
LANE, LARRY &CAROL
48 VISTA ESTATES COURTl
EnerFor
9Y-• -
13620 HWY 99
CHICO, CA 95973
PHONE#: (530) 345-6980
s
Z
3
o
8
"
N
OROVILLE CA 95965
®�
S
O
o
D
a °N
APN:030.038.010 PH#:530.520.6997
Alternative Energy Systems Inc.
FAX#: (530) 892-2360
design@solarenergyforlife.com
-
ACPVARRAY C.DISCONN CT MAIN
HASEF71K71NN71['j
- � �`
ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE 2014
NATIONAL ELECTRIC CODE (NEC), OR LOCAL MUNICIPAL CODE, AND
FIRE DISTRICT REGULATIONS.
1. ALL EQUIPMENT SHALL BE LISTED AND LABELED PER RECOGNIZED ELECTRICAL TESTING LABORATORY AN
INSTALLED PER THE LISTING REQUIREMENTS AND THE MANUFACTURER'S INSTRUCTIONS.
2. ALL INVERTERS SHALL BE IEEE 929 COMPLIANT AND SHALL BE INSPECTED BY LOCAL UTILITY BEFORE
COMMISSIONING, TESTING, AND OPERATION OF THE SYSTEM.
3. ALL OUTDOOR EQUIPMENT SHALL BE MINIMUM NEMA 3R, INCLUDING OUTDOOR MOUNTED TRANSITION
BOXES, COMBINER BOXES, AND SWITCHES.
4. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ART.250,690.
5. NEC. ART. 690.9(A). ALL CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE OVERCURRENT
DEVICES LOCATED SO AS TO PROVIDE OVERCURRENT PROTECTION FROM ALL SOURCES.
6. NEC ART. 690.18. DUE TO THE FACT THAT PV MODULES ARE ENERGIZED WHENEVER THEY ARE EXPOSED
TO LIGHT, PV CONTRACTOR SHALL DISABLE THE ARRAY DURING INSTALLATION AND SERVICE BY SHORT
CIRCUITING, OPEN CIRCUITING, OR COVERING THE ARRAY WITH AN OPAQUE COVERING.
7. PHOTOVOLTAIC SYSTEM SHALL BACKFEED THE DISTRIBUTION SYSTEM ON SITE PER THE REQUIREMENTS OF
NEC ART.690.64(B). ALL BACKFEED BREAKERS SHALL BE IDENTIFIED AS SUCH AND SHALL BE SECURED IN
PLACE BY ADDITIONAL FASTENER PER THE REQUIREMENTS OF NEC 408.16(F).
8. FALL ARREST PROTECTION PER OSHA REQUIREMENTS SHALL BE PROVIDED FOR ALL ROOF WORK.
9. ALL CONDUCTORS AND TERMINATIONS SHALL BE RATED FOR 75° C MINIMUM.
10. NEC ART. 690.14. -SEE SHEET RE -4.1 FOR LABEL DIAGRAM
11. NEC ART. 690.53. -SEE SHEET RE -4.1 FOR LABEL DIAGRAM
12. NEC ART. 690.17. EACH AC DISCONNECT SHALL ALSO BE LABELED WITH: "WARNING! -ELECTRICAL SHOCK
HAZARD -DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIZE MAYBE ENERGIZED IN
THE OPEN POSITION".
13. GROUNDING OF ALL DWELLINS SHALL BE CONFIRMED.
14. CONTRACTOR TO PROVIDE GROUND FAULT PROTECTION FOR ROOF MOUNTED PHOTOVOLTAIC ARRAYS
LOCATED ON DWELLINGS PER 2014 NEC ART.690.17.
15. WHERE MORE THAN ONE NOMINAL VOLTAGE SYSTEM EXIST, THE DIFFERENT SYSTEMS SHALL
BE IDENTIFIED BY PHASE AND SYSTEM PER 2014 NEC ART.210.4D
16. PROVIDE AN ACCESSIBLE DISCONNECT DEVICE THAT IS LOCKABLE IN OPEN POSITION AND IS
LOCATED WITHIN 10'-0" OF THE METER PER LOCAL ELECTRICAL UTILITY REGULATIONS.
17. PHOTOVOLTAIC SOURCE CURRENTS MUST BERATED AT BOTH 125% OF THE PARALLEL
MODULE AND AT A CONTINUOUS LOAD OF ANOTHER 125% FOR A TOTAL OF 156% OF THE
LOAD.
18. PROVIDE PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE
DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECT MEANS IF THEY ARE
NOT IN THE SAME LOCATION PER 2014 NEC ART.690.56.
19. INSTALLATION OF PV PANEL ARRAYS SHOULD RESIST SLIDING AND POP-UP RESULTING FROM
SEISMIC EVENTS AND SHOULD COMPLY WITH CBC SECTION 1613A AND ASCE STANDARD 7-05,
CHAPTER 13.
20. PV SYSTEM INSTALLER WILL BE RESPONSIBLE FOR FURNISHING AND INSTALLATION OF ALL
RELATED EQUIPMENT, CABLES, ADDITIONAL CONDUITS, BOXES WIREWAYS AND OTHER
ACCESSORIES NECESSARY FOR COMPLETE AND OPERATIONAL PHOTOVOLTAIC SYSTEMS.
21. PV SYSTEM CONTRACTOR SHALL COORDINATE ALL THE WORK WITH THE ENGINEER, THE
CONSTRUCTION MANAGER AND ALL OTHER CONTRACTORS TO ENSURE THAT PV SYSTEM IS
INSTALLED AS SPECIFIED IN THESE DRAWINGS.
22. DRAWING IN GENERAL OR DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF THE
EQUIPMENT AND WORK INCLUDED. THE INTENTION OF THE DRAWING IS TO INDICATE SIZE,
CAPACITY, APPROXIMATE LOCATION AND GENERAL RELATIONSHIP, BUT NOT EXACT DETAIL
OR PHYSICAL PLACEMENT.
23. FIELD VERIFIES EXACT AIC RATING REQUIRED OF THE MAIN SWITCHBOARD FROM LOCAL
UTILITY.
24. A PV SYSTEM WITH MULTIPLE INVERTERS, WHERE INVERTERS ARE REMOTELY LOCATED FROM
EACH OTHER, WILL HAVE A DIRECTORY CREATED FOR EACH LOCATION. AS PER 2014 NEC
690.5(H) AND IN ACCORDANCE WITH 2014 NEC 705.10.
25. A NON FOLDING LADDER WILL BE IN PLACE AND SECURED TO THE ROOF TO PROVIDE ACCESS
FOR ALL INSPECTIONS. ALL 1 BOXES WILL BE OPENED UPON REQUEST.
26. SMOKE AND CARBON MONOXIDE ALARMS WILL BE INSTALLED IN ACCORDANCE WITH CRC R314
R315
6)
m
G
n
o
a
mp
m
LANE,
48 VISTA ESTATES COURT
13620 HWY 99
EneigyFor LffeCHICO,CA95973
PHONE#: (530) 345-6980
s
z
_
ooZ
9
"o
OROVILLE, CA 95965
®00A2360o :()
O
x
APN:030.038.010 PH#:530.520.6997
Alternative Energy Systems Inc, design@so!arenergyfor!ife.com
n `
June 22, 2017 t
To Whom it May Concern; + _
`fn order to meet`future advanced'grid requirements, SunPower® is transitioning from Type C AC modules.to Type D AC,
modules. The purpose of this letter is to demonstrate the mechanical and electrical equivalency of Typ6.0 AC modules .
and Type D AC modules.,Type D AC modules are drop-in replacements for Type C AC modules .and are'available'at the
same DC and AC power,levels. Type D'AG.modules have the same form; fit, and function as Type C AC modules. The AC"
electrical output specifications,of Type C AC -modules and Type'D AC modules are equivalent, ensuring intercFangeability
for AC conductors, overcurrent protection devices, and grounding. " ^
SunPower Type D AC modules are certified.per UL 1741 SA to the following SRDs: IEEE 1547, IEEE 1547a, and CPUC Rule; -
'21.Phase L :These additionaftertifications and functionality enable Type D AC modules to meet California CPUC-Rule-21f''
Phase 1 smart inverter requirements. The following table lists the Type C AC module models and their respective Type D
equivalents,•as of the date of,this letter: �.."
Where Type D AC modules are substituted in the field for Type C AC modules, no changes to the physical layout, structural
loading, electrical design, -or interconnection are required. y
Should you have any questions or concernsplease contact SunPower Technical Support at 1-800-786-7693. Y'
Best Regards, '
Matt Mayberry
Director, Residential Product Management~ r
E19 -320 -C -AC
E19 -320 -D -AC
E207327 -C -AC=,-
E20 -327 -D -AC: ,.
' 'X21.335-BLK-C-AC
X21-335-BLK-D-AC `
X21=335 -C -AC
X21 -335 -D -AC
` X21 -345 -C=AC :'
» ' X21 -345 -D -AC '
X22 -360 -C -AC,' `
X22=360 -D -AC
Where Type D AC modules are substituted in the field for Type C AC modules, no changes to the physical layout, structural
loading, electrical design, -or interconnection are required. y
Should you have any questions or concernsplease contact SunPower Technical Support at 1-800-786-7693. Y'
Best Regards, '
Matt Mayberry
Director, Residential Product Management~ r
Design -Driven Advantages
#1 module aesthetics and efficiency'
Unmatched module reliability2
No electrolytic capacitors
25 -year Combined Power and Product
Warranty
Maximize Value for Roof
Size system for roof, not string inverter
Optimize performance of each module
Expand Deployment Options
Complex roofs and partial shading
Small systems
System expandability
Simplify & Speed Installation
Factory -integrated microinverter
Robust, double -locking AC connectors
Design flexibility offsite and onsite
No DC string sizing process
Fewer installation steps than competing
systems
Intuitive commissioning
Component of Complete System
Built for use with SunPower° InvisiMount`,"
and the SunPower Monitoring System
Superior system reliability and aesthetics
,= t
Optimize System and Installation Efficiency _
SunPower®AC Modules, which include a factory -integrated
SunPower microinverter, provide a revolutionary combination of high
efficiency, high reliability, and module -level DC -to -AC power conversion.
Designed specifically for use with SunPo%njer InvisiMount"I and the
Sun°ower,iMonitoring System, SunPower AC Modules enable rapid.
installation, best -in -class system aesthetics, aid intuitive visibility into
system performance. All this comes with the best Combined Power
and Product Warranty. y
� /: • � +. Jnr • . .. � r t
ZZ
,
�}
sunpower.corn
n+a wQ
4
*
y T
X�y ,,3 .�wi � tt�'i a•r .� ,.Y: .. � -.: ! 1 {�. ` �v �,t � ��1�j��
• ix
�.
-• ••- • R.1115
Output @ 240 V (min./nom./max.)
Output @ 208 V (min./nom./max.)
SPR -X21 -345 -C -AC SPR -X21335 -C -AC
Nominal Power'(Pnom) 345 W 335 W
Power Tolerance Y
` s 2 +5/-0% +5/-0%
Avg. Panel Efficiency'-
21.5°/% 21.0%
Temp. Coef. (Power)
-0.30%/°C -
Shade_ Tolerance
'
` ' Three bypass diodes
integrated module -level maximum power
point tracking
• ix
�.
-• ••- • R.1115
Output @ 240 V (min./nom./max.)
Output @ 208 V (min./nom./max.)
211/240/264 V
183/208/229 V
Operating Frequency (min./nom./max.)
59.3/60.0/60.5 Hz
Output Power Factor (min.)
0.99
AC Max. Continuous Output Current @ 240 V
AC Max. Continuous Output Current @ 208 V
1.33 A
1.54 A
AC Max. Cont. Output Power,-
320 W
DC/AC CEC Conversion Eficieney
96.0%
Max. Units Per 20 A Branch Circuit @ 240 V
Max. Units Per. 20 A Branch'Circuit @ 208 V
12 (single phase)
10 (two pole)
1-147
-• ••- • R.1115
Operating Temp.
-40° F to X185° F (-40° C to +85° C)
Iviax. Ambient Temp.
122° F (50° C)
Max. Load
Wind`. 62 psf, 3000 Pa, 305 kg/m2 front & back
Environmental
Snow: 125 psf, 6000 Pa, 611kg/M2 front
mpact Resistance
ri
1 inch (25 mm) diameter hail at 52 mph (23
Frame
M/S) •
'Highest of over 3,200 silicon solar panels, Photon Module Survey, Feb. 201 A.
=?i1 rank in'PV Module Durabiliy Initiative Public Report." Fraunhofer CSE, Feb 2013. Five out o` the
top eight largest manufacturers were tested. Campeau, Z et al. "SunPower Module Degradation Rate."
SunPower Aite paper, Feb 2013. See wmm.sunpower.com/(acts for details.
=Scandall d Test Conditions (1000 W/m2 irradiance, AM 1.5, 250 a NREL calibration standard: Soms
current, LACCS FF and voltage. All DC voltage is fully contained within the module.
`Based on average or measured power values during production.
See wwwsunpbwer.com/facts for more reference information.
For more details, see extended datasheet: wwvr.sunpoweccont/datasheets.
m
OR ORW
Solar Cells
96 Monocrystalline 1Maxeon(O Gen III
Front Glass
High -transmission tempered glass with ariti-
reflective coating ,•
Environmental
y
Outdoor rated
Rating
IEEE 1547.1
Frame
Class 1 black anodized (highest HAMA ra[ingj
Weight
45.5 Ibis (20.6 kg) t
Max.
UL 2703 Listed when installed with'
'Recommended
1.3 in. (33 mm) t
Module Spacing
280 mm
[11.02 in7
1107 mm E c
E�
30
(43.6 in)
10x6 mm ' v�
1 [41.2 in) '. � '
t
it m
[1.2 Int
1558 mm f
[61.3 int
Please read the safety and installation instructions for details.
Document 4 515215 Rev 8 /LTR US
Warranties
25 -year limited power warranty'
25 ear limited product warranty '
UL 1741, including compliance with
applicable requirements of IEEE 1547 and
IEEE 1547.1
AC module Type 2 Fire Rated t•
UL 2703 Listed when installed with'
y
InvisiMountTM
Certifications
,
.. ,
Class A Fire Rated when installed with
InvisiMount'•' and when distance between
roof surface and bottom of SunPower
module frame is <- 3.5" (8.89 cm) ..
Alternating Current (AC) Module'designation
enables installation in accordance with NEC
690.6 `
PID Test
Potential -induced degradation free
280 mm
[11.02 in7
1107 mm E c
E�
30
(43.6 in)
10x6 mm ' v�
1 [41.2 in) '. � '
t
it m
[1.2 Int
1558 mm f
[61.3 int
Please read the safety and installation instructions for details.
Document 4 515215 Rev 8 /LTR US
punt Cmmno
ti Module- / Mid'Clamp and Rail Module* / cnd Clamp and Pail
r t
Mid Clamp End Clamp Rail & Rail Splice End Cap
Composition Shingle Rafter Attachment
Application Ccmpositien Shingle Roof Decking Attachment
Curved and Flat Tile Roof Attachment
Universal Interface for Other Roof Attachments
InvisiMou-ntOperatingConditions
Temperature
Component
'�6u ntComponent Details
Material
Weight
Mid Clamp
Black oxide stainless steel AISI 304
63 g (2.2 oz)
End Clamp
Black anodized aluminum alloy 6063-T6
110 g (3.35 oz)
Rail
Black anodized aluminum alloy 6005-T6
330 Vm (9 oz/ft)
Rail SoliCe
Aluminum alloy 6005 -TS
330 g/m (9 oz/ft)
Ground Lug
assembly
304 stainless ,
(A2-70 bolt, tin-plated copper lug)
106.5 g!m (3.75 oz)
End Cap
Black acetal (POM) copolymer
10.4g (0.37 oz)
Composition Shingle Rafter Attachment
Application Ccmpositien Shingle Roof Decking Attachment
Curved and Flat Tile Roof Attachment
Universal Interface for Other Roof Attachments
*Module frame that is compatible with the InvisiMount system required for hardware interoperabllicy. .
5 2015 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER lo;o, and INVISIMOUNT are trademarks or repstered .
crademarks of SunPower Corpora uon. All other trademarks are the property of their respective owners. sunpower.com
Specifications included in this datasheet are subject to change without notice. Document #509506 Rev 8
InvisiMou-ntOperatingConditions
Temperature
-40° C to 90° C (-40° F to 194° F)
Max. Load
2400 Pa uplift
54.00 Pa downforce
InvisiMount
Warranties And Certifications
Warranties
25 -year product warranty
5 -year finish warranty
UL 2703 Listed
Certifications
Class A fire rating when distance between
roof surface and d bottom of SunPower
module frame is <- 3.5"
Roof Attachment Hardware
Refer to roof attachment hardware manufacturer's documentation
*Module frame that is compatible with the InvisiMount system required for hardware interoperabllicy. .
5 2015 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER lo;o, and INVISIMOUNT are trademarks or repstered .
crademarks of SunPower Corpora uon. All other trademarks are the property of their respective owners. sunpower.com
Specifications included in this datasheet are subject to change without notice. Document #509506 Rev 8
DETAIL
.INVISIMOUNT. •RACKING
_
t_ SOLAR MODULE
< . �, J_ ; - •;, <- .r
' END CLAMP
i
MID CLAMP
INVISIMOUNT RAIL-
*EACH MID CLAMP
GROUNDS THE
`
MODULE TO THE RAIL
-
t 3. .. •'
ate.
^'.r-- � •.
�...
: ..
-..
_
C
,- �..
�L
-INVISIMOUNT RAIL
s
-
� »• ' " `
..
..' ..
L FOO ,. ..
GreenFasten`" GF1 — Product Guide Installation Instructions with Compression Bracket
t r
2
5
Consult an engineer or go to www.ecofastensolar.com
for engineering data.
3 4a 4b 4c
1. Locate the rafters and snap horizontal and vertical lines to mark the installation position for
each GreenFasten flashing.
2. Drill a pilot hole (1/4"diameter) for the lag bolt. Backfill with sealant. EcoFasten Solar
recommends an EPDM mastic.
3. Insert the flashing so the top part is under the next row of shingles and pushed far enough
up slope to prevent water infiltration through vertical joint in shingles. The leading edge of
flashing must butt against upper row of nails to prevent turning when tourqued. See page
2.2 for vertical adjustment when leading edge of flashing hits nails in upper shingle courses.
4. Line up pilot hole with GreenFasten flashing hole.
4a Insert the lag bolt through the EPDM washer, the top compression component bracket (L-
102-3, L-102-6*, SCL-101-3*, Z-101*, Conduit Mount Bracket*) and the gasketed hole in the
flashing and into the rafter.
4b Insert the lag bolt through the EPDM washer, the Comp Mount Slide compression
bracket and the gasketed hole in the flashing and into the rafter.
4c Insert the lag bolt through the SS wdsher, the third -party bracket, the EPDM bonded
washer, the CP -SQ -Slotted compression bracket and the gasketed hole in the flashing
and into the rafter.
5. Torque: The range is between 100-140 torque inch -pounds depending on the type of wood
and time of year. The visual indicator for proper torque is when the EPDM on the underside
of the bonded washer begins to push out the sides as the washer compresses. If using an
impact wrench to install the fasteners be careful not to over torque the fastener. You may
need to stop and use a ratchet to finish the install.
*not pictured.
877-859-3947 EcoFasten Solar' All content protected under copyright. All rights reserved. 7/24/2014
EcoFasten Solar products are protected by the tollowina U.S. Patents: 8,151.522 82 8,153,700 132 8,181,398 132 8,166.713 132 8.146.299 132 8,209.914 82 8.245.454 B2 8.272.174 132 8,225.557 132
2.1
L
2
5
Consult an engineer or go to www.ecofastensolar.com
for engineering data.
3 4a 4b 4c
1. Locate the rafters and snap horizontal and vertical lines to mark the installation position for
each GreenFasten flashing.
2. Drill a pilot hole (1/4"diameter) for the lag bolt. Backfill with sealant. EcoFasten Solar
recommends an EPDM mastic.
3. Insert the flashing so the top part is under the next row of shingles and pushed far enough
up slope to prevent water infiltration through vertical joint in shingles. The leading edge of
flashing must butt against upper row of nails to prevent turning when tourqued. See page
2.2 for vertical adjustment when leading edge of flashing hits nails in upper shingle courses.
4. Line up pilot hole with GreenFasten flashing hole.
4a Insert the lag bolt through the EPDM washer, the top compression component bracket (L-
102-3, L-102-6*, SCL-101-3*, Z-101*, Conduit Mount Bracket*) and the gasketed hole in the
flashing and into the rafter.
4b Insert the lag bolt through the EPDM washer, the Comp Mount Slide compression
bracket and the gasketed hole in the flashing and into the rafter.
4c Insert the lag bolt through the SS wdsher, the third -party bracket, the EPDM bonded
washer, the CP -SQ -Slotted compression bracket and the gasketed hole in the flashing
and into the rafter.
5. Torque: The range is between 100-140 torque inch -pounds depending on the type of wood
and time of year. The visual indicator for proper torque is when the EPDM on the underside
of the bonded washer begins to push out the sides as the washer compresses. If using an
impact wrench to install the fasteners be careful not to over torque the fastener. You may
need to stop and use a ratchet to finish the install.
*not pictured.
877-859-3947 EcoFasten Solar' All content protected under copyright. All rights reserved. 7/24/2014
EcoFasten Solar products are protected by the tollowina U.S. Patents: 8,151.522 82 8,153,700 132 8,181,398 132 8,166.713 132 8.146.299 132 8,209.914 82 8.245.454 B2 8.272.174 132 8,225.557 132
2.1
L
GreenFasten" GF1 - Product Guide
104 11,11A
Installation Instructions
*Use for vertical adjustment when leading edge of flashing hits nails in upper shingle courses .
. Slide flashing up under shingles until leading edge
engages nails. Measure remaining distance to adjust
shingle
�i1•r Mj `W �7 f r. } �l� •,. moi; � . � y .�-.t;TS �'S .�'�
�T
.j
3. Reinstall flashing with notched area upslope. 4. Position notched leading edge underneath nail heads as shown.
je Nails beneath shinqle —J Nails beneath shingle
2. Remove flashing and cut "V" notch at marks where nail shafts
engaged leading edge of flashing the distance desired in Step 1.
Notch depth not to exceed 2" length by 1/2" width.
/#,/. Placement of"V" notch
1 877-859-3947 EcoFasten Solar®All content protected under copyright. All rights reserved. 7/24/2014 2.2
' EcoFasten Solar products are orotected by the following U.S. Patents: 8.151,522 B2 8.153.700 B2 8.181,398 B2 8,166.713 B2 8,146.299 82 8,209.914 B2 8.245.454 B2 8.272.174 B2 8,225,557 B2
GreenFasten:" GF1 - Product Guide , i �: -Cut Sheets: GF,1.
tA
4 '
a
� If701
r -SECTION A=A
3 i
Al
� 111, . ' .. . ` _ a", _ _ � •r,,. � - �'
" a 1 877-859-3947 EcoFasten Solar" All content protected under copyright. All rights reserved. 7/24/2014 :{, ' 3.1
` r EcoFasten. Solar products are protected by the following U.S. Patents: 8.151,522 B2 8,153.700 B2 8.181,398 B2 8.166.713 B2 8,146,299 B2 8,209,914 B2 8.245,454 B2 8,272.174 B2 8.225.557 B2
GreenFasten" GF1 - Product Guide ; . Cut Sheets: GF.1= 812
_ 4X R- -
8
0 T6- '
1 {I • � Y u yUr
��
_ 5 - 5/64 x
j
16
t �1 DETAIL A
y „•. 4 SCALE: 2:1
If
�\ t Finish Options
BLK'=Matte Black
'MCL = Mill Finish
1" 877-859-3947 EcoFasten Solar®All content protected under copyright. All rights reserved. 7/24/2014 3.2 •
EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 132 8,1.53,700 82 8,181,398 132 8,166.713 132 8,146,299 132 8,209,914 132 8.245.454 B2 8.272.174 132 8.225.557 B2
t a i i GreenFasten•" GF1 - Product Guide t 4 ' Cut Sheets: Bracket Options CF- SQ -Slotted
,�` � � � � the �:. • � >r _ , - .. - - - '
gill I
Y
.�.� � + �i Cif 1 � - _ . • _ - :. � ... ... - -
F� •�, ti — 1.50
.06
.38 ,
2.00
• 1.0U r `
+'°•� ''"� p 1.00 _ (160.38±.00 S 0.50
0 0.88±.01 X 82°
2.00 $
xa`tDt#• '•i d" T e, ,• ,T _t.. _h, s.„ �,v r r•
877-859'-39 EcoFasten SolarOAll content protected under copyright. All rights reserved. 7/24/2014 _ 3.3
EcoFasten Solar products are protected by the following U.S. Patents: 8.151,522 132 8,153,700 132 8,181,398 B2 8.166.713 B2 8,146,299 82 8,209,914 82 8.245.454 132 8.272,174 B2 8,225.557 B2
In �^�r � t ,' .. - _- , t .. .f ` ' •- ,, I .. - .
GreenFasten'" GF1 =Product Guide k ' ` Cut Sheets: Bracket Options - SCL-101-3"
�� yq, i9� ' ,•f.a - .i • use .t _ i R ._.
•�I r � � • Via. P _ Y •. y'.• s . -� � � -. t, '. + '` r
A.
_ `i y �• _x .-2. .T fir- ,.
a Y T , w , ♦ r. ` _ r . C ' • • S - • j 'a
46 SERRATIONS
,Rill r .. - r •~ ., r _ ..
l k}^5 �111�� }�('1 ��IIf J• �y _ ' �� * F� - y•r '�� a :' (� ••{ ; i ! ., .. •
{6}_ 4 ►j tr�,t �1 + -0
i t �
� r—
+day
R1/16"
-
Tt '1 7/8"
/
c . Ir1
� R.005 ..... ,__
- R01
�� t�.,�� JJ ,. - .• �— — - —' —1-- - ---� � �- 60.00°
Q - - ' •
+ .006 ,1
3/8.. 1 /8
" �Q .002
7
/'8" X $2° _. DETAIL A
SCALE 3:1
877-859-3947 EcoFasten Solar®All content protected under copyright. All rights reserved. 7/24/2014 3.5
r EcoFasten Solar products are protected by the followinq U.S. Patents: 8.151,522 B2 8,153,700 B2 8,181.398 B2 8,166.713 B2 8,146.299 82 8,209,914 B2 8,245.454 B2 8.272.174 B2 8.225,557 B2
GreenFasten-,. F1.- Product Guide -
14 IF ft
V �{
f � � "f -
x
r .r. Cut Sheets: Bracket Options - L-102-3'1
2X.3%8"
46 SERRATIONS
LO
1 7/8"
L
.1 /4"
1/16"
R.005
f
=R1/16
00
R.010
2X R.01
3/8"-.002,. : °60.00
+006
3/V -.002
0.875+.010 X 82•°= . _ DETAIL A
-SCALE 3 1
877-859-3947 EcoFasten Solar" All content protected under copyright. All rights reserved. 7/24/2014 3.6
/ EcoFasten Solar products are protected by the following U.S. Patents: 8.151.522 B2 8.153,700 B2 8,181.398 132 8,166,713 B2 8,146.299 B2 8.209.914 B2 8.245.454 B2 8,272.174 B2 8.225.557 B2
N
N
—
15/16,
N
'
1 7/R1.
.1 /4"
1/16"
R.005
f
=R1/16
00
R.010
2X R.01
3/8"-.002,. : °60.00
+006
3/V -.002
0.875+.010 X 82•°= . _ DETAIL A
-SCALE 3 1
877-859-3947 EcoFasten Solar" All content protected under copyright. All rights reserved. 7/24/2014 3.6
/ EcoFasten Solar products are protected by the following U.S. Patents: 8.151.522 B2 8.153,700 B2 8,181.398 132 8,166,713 B2 8,146.299 B2 8.209.914 B2 8.245.454 B2 8,272.174 B2 8.225.557 B2
AC Circuit Ampacity Calculator Meter #:
Customer Name: LANE, LARRY
t
Location: 48 VISTA ESTATES COURT Orovil,le CA 95965
Wire Note: AC -1 Description: INVERTER TO AC DISTRIBUTION PANEL
Wire Calculation
3.84 kWatts VAC Split Voltage Configuration TRUE TL Inverter?
10 Minimum Wire and.Conduit Size based on_'Voltage Drop'and.Ampacity` +`�. 10 Minimum.Ground Size,Based on NEC
20.00 A Minimum Ciruit Breaker/Fuse Size - c' : 10 Actual Ground Size Based on NEC
20.00 A' . 'Ampacity After Derate, 10 Wire Size,
Based on Ampacity M 30 A r
0.6613 % of Voltage. Drop 10 Wire Size Based on.Voltage Drop 30 A }
16 A, Circuit Ampacity 1 Factor : ' . 1 Phases '
0.96 Conditions of Use Derate Factor
16.67 A Minimum Conductor. Ampacity Based on Conditions of Use
20.00 A Minimum Conductor Ampacity Based on 1.25 Rule `
Conditions of Use
0.96 Derate Total
35. °C Temp Coef (ambient + Sunlight)95 °F, 0.96 Derate
35 °C Ambient Temp 95 °F ;
none Sunlight Exposure ` 732 °F0 °C Temp adder
J`
3 or lessl Number of Current Carrying Conductors 1 1 Derate applied to Temp Coeficient ;
Y 8 fl . -11.1 %;.iv,u, _ ii&, v _ _
2_40V Circuit Voltage 16 A Circuit Amps 1.24 Resistance
40 ft One Way Distance 10 Wire Size 0,.6613 % of Loss
Conduit Size (Conduit Fill Can Not be more than 40%)
None Conduit Type 0.16 Wire Size Diameter - #N/A Conduit Fill percentage
- 1 Conduit Size 0.16 Ground Wire Size Diameter #N/A Conduit Internal Diameter
600 V System Voltage - THW
VN-2 Wire Type - -�
/ ._ .'f'} i.. • r •t . ' �,. r•J• ..k- ..- r . .. as ,.1' , .♦ ', - •' �k- ,• ..- r