HomeMy WebLinkAboutB17-1977 030-038-010i • DEVELOPMENT SERVICES BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES INSPECTION CARD MUST BE ON JOB SITE 24 Hour Inspection Line (IVR) : 530.538.4365 (Cut off time for inspectioes is 3pm) Development Services cannot guarantee inspections on the date re-Iuested Office: 530.538.7601 Fax: 530.538.7785 www.ButteCounty.net/dds Permit No: B 17-1977. Issued: 8/29/2017 APN: 030-038-010 Address: 48 VISTA ESTATES COURT, OROVILLE Owner: LANE, LARRY Permit Type:. SOLAR ROOF -RES Description: Install 4.14kw roof mount to existing meter AREA 1 Flood Zone: AE SRA Area: No ,SETBACKS for Zn-ninv- AG- SR -'PW Front: Centerline of Road: Rear: SRA: Street: AG: Interior Total Setback from Centerline of Road: ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING Inspection Tyve IVR INSP . DATE Setbacks 131 Foundations / Footings 111 Pier/Column Footings 122 Eufer Ground 216 Masonry Grout 120 Setbacks 131 Do Not Pour Concrete Until Above are Signed Pre -Slab 124 Gas Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing 149 Underfloor Ducts 319 Shear Transfer 136. Under Floor Plumbin 412 Under Slab Plumbing 411 Blockin nd_e" inin 612 Tiedown/Soft Set System 611 Do Not Install Floor Sheathing or Slab Until Above Signed Shearwall/B.W.P.-Interior 134 Shearwall/B.W.P.-Exterior 135 Roof Nail/Drag Trusses 129 Manometer Test 605 Do Not Install Siding/Stucco or Roofing Until Above Signed Rough Framing 153 Rough Plumbing 406 Rough Mechanical 316 Rough Electrical 208 4 -Way Rough Framing 128 Gas Piping House 403 Gas Test House 404 Shower Pan/Tub Test 408 Do Not Insulate Until Above Signed Permit Final 802 Electrical Final 803 Mechanical Final 809 Plumbing Final 813 Fire Sprinkler Test or Final 702 Swimm-Ing Pools Inspection Type IVR INSP DATE T -Bar Ceiling 145 Stucco Lath 142 Swimm-Ing Pools Setbacks 131 Pool Plumbing Test 504 Gas Test 404 Pre-Gunite 506 Pre -Deck 505 Pool Fencing/Alarms/Barriers �j 503 Pre -Plaster 507 Manufactured Homes Setbacks 131 Blockin nd_e" inin 612 Tiedown/Soft Set System 611 Permanent Foundation System. 613 Underground Electric 218 Sewer 407 Underground Water 417 Manometer Test 605 Continuitv Test 602 Skirting/Steps/Landings 610 Coach Info Manufactures Name: Date of Manufacture: Model Name/Number: Serial Numbers: Length x Width: Insignia: Finals, Public Works Final 538.7681 Fire De artment/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final "PROJECT FINAL °1 t4'17 rrolect rLnaL is a %-ernncaL-- oT occupancy for kxesLoennaL unry) PERMITS BECOME NULL AND VOID 1 YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A 1 YEAR RENEWAL 30 DAYS PRIOR TO EXPIRATION. PROJECT OWNER: LANE, LARRY & CAROL 48 VISTA ESTATES COURT OROVILLE , CA 95965 APN:030.038.010 PH#:530.520.6997 EMAIL:Iarry@kingdomc.org CONTRACTOR: ALTERNATIVE ENERGY SYSTEMS INC. 13620 HIGHWAY 99 CHICO, CA 95973 CSLB: 853351 C-10, C-46 BUILDING JURISDICTION: BUTTE COUNTY DEPT. OF DEVELOPMENT SERVICES 7 COUNTY CENTER DRIVE OROVILLE, CA 95965 OFFICE#: (530) 538-7601 FAX#: (530) 538-2140 MON-FRI 8AM-3PM INSPECTION LINE: (530) 538-4365 REQUESTS PHONED IN BY 2PM WILL BE INSPECTED THE NEXT BUSINESS DAY L...qc co SCOPE: INSTALL PHOTOVOLTAIC SOLAR SYSTEM ON A TRUSS ROOF, MOUNTED IN ACCORDANCE WITH ALL APPLICABLE BUILDING CODES SPECIFICALLY REFERENCING THE 2016 CALIFORNIA ELECTRICAL CODE/ 2014 NEC USING THE FOLLOWING SPECIFIC EQUIPMENT.- 1. QUIPMENT:1. MODULES: SUNPOWER (12) SPR -X21 -345 -C -AC 4.14kW SYSTEM 219 SQFT COVERED 2. INVERTER(S): SUNPOWER (12) MODULE INTEGRATED 320W SITE MAP PAGE # CONTENT PV -1.0 SCOPE PV -2.0 SITE PLAN PV -3.0 ARRAY LAYOUT PV -4.0 ELECTRICAL DIAGRAM PV -4.1 LABEL DIAGRAM. PV -5.0 GENERAL NOTES ATTACHMENT MODULE SPECS . INVERTER SPECS o RACKING SPECS 48 VISTA ESTATES COURT WIRE CALCS ' A � o 9 o m �, ° a m . g LANE, LARRY & CAROL , 13620 H 99 Energy for Life 9y. CHICO,CA95973 m <_ LA o C p p o ; 48 VISTA ESTATES COURT PHONE#: (530) 345-6980 z _ OROVILLE , CA 95965 ��® FAX#: (530) 892-2360 °8 APN:030.038.010 PH#:530.520.6997 Alternative Energy Systems Inc. design@solarenergyforlife.com r� ..�. a ., s. � �•+ r • .. V - _ . - i` � �. a1 (E) RESIDENCE (E) COMPOSITION ROOF W/ WOOD TRUSSES T MONITORING INSIDE GARAGE { _ — — R'�/ • � (E) PGCE METER (E) SERVICE PANEL .+ • ^o oZ° = m n� �3� S LARRY &CAROL 13620 HWY 99 "{RICO,CA9973•EnergyForUf' 4LANE, < mz •'N , n _ ^:E�Zp 48VISTA ESTATES COURT PHONE#: (530) 345-6980m o? ' �- OROVILLE CA 95965 APN:030.038.010-PH#:530.520.6997' `'� ' Alternative Energy Systems Inc., -2360-n FAX#: (530) 892. e design@solarenergyforlifexom t •• f - .. V • 'RL • P Y Y "',^ v Y. ' • 1�'' J .. ' ' it � ..'' �. ------------- 6'-011 _ -' J •ATTACHMENTS MAX 6' ON CENTER RAFTERS 24" ON CENTER < LEGEND ; e DIRECT-. 5' PR . 10' PR 3' pp ♦� * ' , 10' PP—� 6' RR 1 10' RR Q� - NOTES RECEPTICAL END CAP 1.ALL ROOF PENETRATIONS PLUG END CAP 0 ` TO BE 72" O.C.'MAXIMUM • 'PARALLELE CONNECTION 0 ARRAY LAYOUT n ^o a S LANE, LARRY &CAROL 13620 HWY 99 m ` . 9 m :. . Energy ForLffe t ' _ o m CHICO, CA 95973 r .. < 1 a a poo" m 48 VISTA ESTATES COURT ,ma_y .. o$ • OW %=p ^D �bm • PHONEi: (530) 345-6980 FAX#: (530) 892-2360_ OROVILLE,CA95965 Alternative Energy Systems Inc 'p APN:030.038.010 PH#:530.520.6997 d6sign@s'ola-renergyforlife.com „. z �. ■ e D ul 0 e 0 ■ i FIRE CODE f .. 10" _ T '� t 61_1111 , ;rE. O ------------- 6'-011 _ -' J •ATTACHMENTS MAX 6' ON CENTER RAFTERS 24" ON CENTER < LEGEND ; e DIRECT-. 5' PR . 10' PR 3' pp ♦� * ' , 10' PP—� 6' RR 1 10' RR Q� - NOTES RECEPTICAL END CAP 1.ALL ROOF PENETRATIONS PLUG END CAP 0 ` TO BE 72" O.C.'MAXIMUM • 'PARALLELE CONNECTION 0 ARRAY LAYOUT n ^o a S LANE, LARRY &CAROL 13620 HWY 99 m ` . 9 m :. . Energy ForLffe t ' _ o m CHICO, CA 95973 r .. < 1 a a poo" m 48 VISTA ESTATES COURT ,ma_y .. o$ • OW %=p ^D �bm • PHONEi: (530) 345-6980 FAX#: (530) 892-2360_ OROVILLE,CA95965 Alternative Energy Systems Inc 'p APN:030.038.010 PH#:530.520.6997 d6sign@s'ola-renergyforlife.com „. z �. ■ e D ul 0 e 0 ■ ------------- 6'-011 _ -' J •ATTACHMENTS MAX 6' ON CENTER RAFTERS 24" ON CENTER < LEGEND ; e DIRECT-. 5' PR . 10' PR 3' pp ♦� * ' , 10' PP—� 6' RR 1 10' RR Q� - NOTES RECEPTICAL END CAP 1.ALL ROOF PENETRATIONS PLUG END CAP 0 ` TO BE 72" O.C.'MAXIMUM • 'PARALLELE CONNECTION 0 ARRAY LAYOUT n ^o a S LANE, LARRY &CAROL 13620 HWY 99 m ` . 9 m :. . Energy ForLffe t ' _ o m CHICO, CA 95973 r .. < 1 a a poo" m 48 VISTA ESTATES COURT ,ma_y .. o$ • OW %=p ^D �bm • PHONEi: (530) 345-6980 FAX#: (530) 892-2360_ OROVILLE,CA95965 Alternative Energy Systems Inc 'p APN:030.038.010 PH#:530.520.6997 d6sign@s'ola-renergyforlife.com „. z �. I I I -I I I AC -1 ON ROOF w/ (2) TRANSITION CABLE �nnoc of iu• c AC -1 SERVICE VOLTAGE 20 = 2= 40 120V=N-L2-L3=NAV NAV=N-L3-LI=NAV , ELECTRICAL DIAGRAM D m a= -0 < mo Z m Z p o n 3 S m LANE, LARRY &CAROL 48 VISTA ESTATES COURTl EnerFor 9Y-• - 13620 HWY 99 CHICO, CA 95973 PHONE#: (530) 345-6980 s Z 3 o 8 " N OROVILLE CA 95965 ®� S O o D a °N APN:030.038.010 PH#:530.520.6997 Alternative Energy Systems Inc. FAX#: (530) 892-2360 design@solarenergyforlife.com - ACPVARRAY C.DISCONN CT MAIN HASEF71K71NN71['j - � �` ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE 2014 NATIONAL ELECTRIC CODE (NEC), OR LOCAL MUNICIPAL CODE, AND FIRE DISTRICT REGULATIONS. 1. ALL EQUIPMENT SHALL BE LISTED AND LABELED PER RECOGNIZED ELECTRICAL TESTING LABORATORY AN INSTALLED PER THE LISTING REQUIREMENTS AND THE MANUFACTURER'S INSTRUCTIONS. 2. ALL INVERTERS SHALL BE IEEE 929 COMPLIANT AND SHALL BE INSPECTED BY LOCAL UTILITY BEFORE COMMISSIONING, TESTING, AND OPERATION OF THE SYSTEM. 3. ALL OUTDOOR EQUIPMENT SHALL BE MINIMUM NEMA 3R, INCLUDING OUTDOOR MOUNTED TRANSITION BOXES, COMBINER BOXES, AND SWITCHES. 4. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ART.250,690. 5. NEC. ART. 690.9(A). ALL CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE OVERCURRENT DEVICES LOCATED SO AS TO PROVIDE OVERCURRENT PROTECTION FROM ALL SOURCES. 6. NEC ART. 690.18. DUE TO THE FACT THAT PV MODULES ARE ENERGIZED WHENEVER THEY ARE EXPOSED TO LIGHT, PV CONTRACTOR SHALL DISABLE THE ARRAY DURING INSTALLATION AND SERVICE BY SHORT CIRCUITING, OPEN CIRCUITING, OR COVERING THE ARRAY WITH AN OPAQUE COVERING. 7. PHOTOVOLTAIC SYSTEM SHALL BACKFEED THE DISTRIBUTION SYSTEM ON SITE PER THE REQUIREMENTS OF NEC ART.690.64(B). ALL BACKFEED BREAKERS SHALL BE IDENTIFIED AS SUCH AND SHALL BE SECURED IN PLACE BY ADDITIONAL FASTENER PER THE REQUIREMENTS OF NEC 408.16(F). 8. FALL ARREST PROTECTION PER OSHA REQUIREMENTS SHALL BE PROVIDED FOR ALL ROOF WORK. 9. ALL CONDUCTORS AND TERMINATIONS SHALL BE RATED FOR 75° C MINIMUM. 10. NEC ART. 690.14. -SEE SHEET RE -4.1 FOR LABEL DIAGRAM 11. NEC ART. 690.53. -SEE SHEET RE -4.1 FOR LABEL DIAGRAM 12. NEC ART. 690.17. EACH AC DISCONNECT SHALL ALSO BE LABELED WITH: "WARNING! -ELECTRICAL SHOCK HAZARD -DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIZE MAYBE ENERGIZED IN THE OPEN POSITION". 13. GROUNDING OF ALL DWELLINS SHALL BE CONFIRMED. 14. CONTRACTOR TO PROVIDE GROUND FAULT PROTECTION FOR ROOF MOUNTED PHOTOVOLTAIC ARRAYS LOCATED ON DWELLINGS PER 2014 NEC ART.690.17. 15. WHERE MORE THAN ONE NOMINAL VOLTAGE SYSTEM EXIST, THE DIFFERENT SYSTEMS SHALL BE IDENTIFIED BY PHASE AND SYSTEM PER 2014 NEC ART.210.4D 16. PROVIDE AN ACCESSIBLE DISCONNECT DEVICE THAT IS LOCKABLE IN OPEN POSITION AND IS LOCATED WITHIN 10'-0" OF THE METER PER LOCAL ELECTRICAL UTILITY REGULATIONS. 17. PHOTOVOLTAIC SOURCE CURRENTS MUST BERATED AT BOTH 125% OF THE PARALLEL MODULE AND AT A CONTINUOUS LOAD OF ANOTHER 125% FOR A TOTAL OF 156% OF THE LOAD. 18. PROVIDE PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECT MEANS IF THEY ARE NOT IN THE SAME LOCATION PER 2014 NEC ART.690.56. 19. INSTALLATION OF PV PANEL ARRAYS SHOULD RESIST SLIDING AND POP-UP RESULTING FROM SEISMIC EVENTS AND SHOULD COMPLY WITH CBC SECTION 1613A AND ASCE STANDARD 7-05, CHAPTER 13. 20. PV SYSTEM INSTALLER WILL BE RESPONSIBLE FOR FURNISHING AND INSTALLATION OF ALL RELATED EQUIPMENT, CABLES, ADDITIONAL CONDUITS, BOXES WIREWAYS AND OTHER ACCESSORIES NECESSARY FOR COMPLETE AND OPERATIONAL PHOTOVOLTAIC SYSTEMS. 21. PV SYSTEM CONTRACTOR SHALL COORDINATE ALL THE WORK WITH THE ENGINEER, THE CONSTRUCTION MANAGER AND ALL OTHER CONTRACTORS TO ENSURE THAT PV SYSTEM IS INSTALLED AS SPECIFIED IN THESE DRAWINGS. 22. DRAWING IN GENERAL OR DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF THE EQUIPMENT AND WORK INCLUDED. THE INTENTION OF THE DRAWING IS TO INDICATE SIZE, CAPACITY, APPROXIMATE LOCATION AND GENERAL RELATIONSHIP, BUT NOT EXACT DETAIL OR PHYSICAL PLACEMENT. 23. FIELD VERIFIES EXACT AIC RATING REQUIRED OF THE MAIN SWITCHBOARD FROM LOCAL UTILITY. 24. A PV SYSTEM WITH MULTIPLE INVERTERS, WHERE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, WILL HAVE A DIRECTORY CREATED FOR EACH LOCATION. AS PER 2014 NEC 690.5(H) AND IN ACCORDANCE WITH 2014 NEC 705.10. 25. A NON FOLDING LADDER WILL BE IN PLACE AND SECURED TO THE ROOF TO PROVIDE ACCESS FOR ALL INSPECTIONS. ALL 1 BOXES WILL BE OPENED UPON REQUEST. 26. SMOKE AND CARBON MONOXIDE ALARMS WILL BE INSTALLED IN ACCORDANCE WITH CRC R314 R315 6) m G n o a mp m LANE, 48 VISTA ESTATES COURT 13620 HWY 99 EneigyFor LffeCHICO,CA95973 PHONE#: (530) 345-6980 s z _ ooZ 9 "o OROVILLE, CA 95965 ®00A2360o :() O x APN:030.038.010 PH#:530.520.6997 Alternative Energy Systems Inc, design@so!arenergyfor!ife.com n ` June 22, 2017 t To Whom it May Concern; + _ `fn order to meet`future advanced'grid requirements, SunPower® is transitioning from Type C AC modules.to Type D AC, modules. The purpose of this letter is to demonstrate the mechanical and electrical equivalency of Typ6.0 AC modules . and Type D AC modules.,Type D AC modules are drop-in replacements for Type C AC modules .and are'available'at the same DC and AC power,levels. Type D'AG.modules have the same form; fit, and function as Type C AC modules. The AC" electrical output specifications,of Type C AC -modules and Type'D AC modules are equivalent, ensuring intercFangeability for AC conductors, overcurrent protection devices, and grounding. " ^ SunPower Type D AC modules are certified.per UL 1741 SA to the following SRDs: IEEE 1547, IEEE 1547a, and CPUC Rule; - '21.Phase L :These additionaftertifications and functionality enable Type D AC modules to meet California CPUC-Rule-21f'' Phase 1 smart inverter requirements. The following table lists the Type C AC module models and their respective Type D equivalents,•as of the date of,this letter: �.." Where Type D AC modules are substituted in the field for Type C AC modules, no changes to the physical layout, structural loading, electrical design, -or interconnection are required. y Should you have any questions or concernsplease contact SunPower Technical Support at 1-800-786-7693. Y' Best Regards, ' Matt Mayberry Director, Residential Product Management~ r E19 -320 -C -AC E19 -320 -D -AC E207327 -C -AC=,- E20 -327 -D -AC: ,. ' 'X21.335-BLK-C-AC X21-335-BLK-D-AC ` X21=335 -C -AC X21 -335 -D -AC ` X21 -345 -C=AC :' » ' X21 -345 -D -AC ' X22 -360 -C -AC,' ` X22=360 -D -AC Where Type D AC modules are substituted in the field for Type C AC modules, no changes to the physical layout, structural loading, electrical design, -or interconnection are required. y Should you have any questions or concernsplease contact SunPower Technical Support at 1-800-786-7693. Y' Best Regards, ' Matt Mayberry Director, Residential Product Management~ r Design -Driven Advantages #1 module aesthetics and efficiency' Unmatched module reliability2 No electrolytic capacitors 25 -year Combined Power and Product Warranty Maximize Value for Roof Size system for roof, not string inverter Optimize performance of each module Expand Deployment Options Complex roofs and partial shading Small systems System expandability Simplify & Speed Installation Factory -integrated microinverter Robust, double -locking AC connectors Design flexibility offsite and onsite No DC string sizing process Fewer installation steps than competing systems Intuitive commissioning Component of Complete System Built for use with SunPower° InvisiMount`," and the SunPower Monitoring System Superior system reliability and aesthetics ,= t Optimize System and Installation Efficiency _ SunPower®AC Modules, which include a factory -integrated SunPower microinverter, provide a revolutionary combination of high efficiency, high reliability, and module -level DC -to -AC power conversion. Designed specifically for use with SunPo%njer InvisiMount"I and the Sun°ower,iMonitoring System, SunPower AC Modules enable rapid. installation, best -in -class system aesthetics, aid intuitive visibility into system performance. All this comes with the best Combined Power and Product Warranty. y � /: • � +. Jnr • . .. � r t ZZ , �} sunpower.corn n+a wQ 4 * y T X�y ,,3 .�wi � tt�'i a•r .� ,.Y: .. � -.: ! 1 {�. ` �v �,t � ��1�j�� • ix �. -• ••- • R.1115 Output @ 240 V (min./nom./max.) Output @ 208 V (min./nom./max.) SPR -X21 -345 -C -AC SPR -X21335 -C -AC Nominal Power'(Pnom) 345 W 335 W Power Tolerance Y ` s 2 +5/-0% +5/-0% Avg. Panel Efficiency'- 21.5°/% 21.0% Temp. Coef. (Power) -0.30%/°C - Shade_ Tolerance ' ` ' Three bypass diodes integrated module -level maximum power point tracking • ix �. -• ••- • R.1115 Output @ 240 V (min./nom./max.) Output @ 208 V (min./nom./max.) 211/240/264 V 183/208/229 V Operating Frequency (min./nom./max.) 59.3/60.0/60.5 Hz Output Power Factor (min.) 0.99 AC Max. Continuous Output Current @ 240 V AC Max. Continuous Output Current @ 208 V 1.33 A 1.54 A AC Max. Cont. Output Power,- 320 W DC/AC CEC Conversion Eficieney 96.0% Max. Units Per 20 A Branch Circuit @ 240 V Max. Units Per. 20 A Branch'Circuit @ 208 V 12 (single phase) 10 (two pole) 1-147 -• ••- • R.1115 Operating Temp. -40° F to X185° F (-40° C to +85° C) Iviax. Ambient Temp. 122° F (50° C) Max. Load Wind`. 62 psf, 3000 Pa, 305 kg/m2 front & back Environmental Snow: 125 psf, 6000 Pa, 611kg/M2 front mpact Resistance ri 1 inch (25 mm) diameter hail at 52 mph (23 Frame M/S) • 'Highest of over 3,200 silicon solar panels, Photon Module Survey, Feb. 201 A. =?i1 rank in'PV Module Durabiliy Initiative Public Report." Fraunhofer CSE, Feb 2013. Five out o` the top eight largest manufacturers were tested. Campeau, Z et al. "SunPower Module Degradation Rate." SunPower Aite paper, Feb 2013. See wmm.sunpower.com/(acts for details. =Scandall d Test Conditions (1000 W/m2 irradiance, AM 1.5, 250 a NREL calibration standard: Soms current, LACCS FF and voltage. All DC voltage is fully contained within the module. `Based on average or measured power values during production. See wwwsunpbwer.com/facts for more reference information. For more details, see extended datasheet: wwvr.sunpoweccont/datasheets. m OR ORW Solar Cells 96 Monocrystalline 1Maxeon(O Gen III Front Glass High -transmission tempered glass with ariti- reflective coating ,• Environmental y Outdoor rated Rating IEEE 1547.1 Frame Class 1 black anodized (highest HAMA ra[ingj Weight 45.5 Ibis (20.6 kg) t Max. UL 2703 Listed when installed with' 'Recommended 1.3 in. (33 mm) t Module Spacing 280 mm [11.02 in7 1107 mm E c E� 30 (43.6 in) 10x6 mm ' v� 1 [41.2 in) '. � ' t it m [1.2 Int 1558 mm f [61.3 int Please read the safety and installation instructions for details. Document 4 515215 Rev 8 /LTR US Warranties 25 -year limited power warranty' 25 ear limited product warranty ' UL 1741, including compliance with applicable requirements of IEEE 1547 and IEEE 1547.1 AC module Type 2 Fire Rated t• UL 2703 Listed when installed with' y InvisiMountTM Certifications , .. , Class A Fire Rated when installed with InvisiMount'•' and when distance between roof surface and bottom of SunPower module frame is <- 3.5" (8.89 cm) .. Alternating Current (AC) Module'designation enables installation in accordance with NEC 690.6 ` PID Test Potential -induced degradation free 280 mm [11.02 in7 1107 mm E c E� 30 (43.6 in) 10x6 mm ' v� 1 [41.2 in) '. � ' t it m [1.2 Int 1558 mm f [61.3 int Please read the safety and installation instructions for details. Document 4 515215 Rev 8 /LTR US punt Cmmno ti Module- / Mid'Clamp and Rail Module* / cnd Clamp and Pail r t Mid Clamp End Clamp Rail & Rail Splice End Cap Composition Shingle Rafter Attachment Application Ccmpositien Shingle Roof Decking Attachment Curved and Flat Tile Roof Attachment Universal Interface for Other Roof Attachments InvisiMou-ntOperatingConditions Temperature Component '�6u ntComponent Details Material Weight Mid Clamp Black oxide stainless steel AISI 304 63 g (2.2 oz) End Clamp Black anodized aluminum alloy 6063-T6 110 g (3.35 oz) Rail Black anodized aluminum alloy 6005-T6 330 Vm (9 oz/ft) Rail SoliCe Aluminum alloy 6005 -TS 330 g/m (9 oz/ft) Ground Lug assembly 304 stainless , (A2-70 bolt, tin-plated copper lug) 106.5 g!m (3.75 oz) End Cap Black acetal (POM) copolymer 10.4g (0.37 oz) Composition Shingle Rafter Attachment Application Ccmpositien Shingle Roof Decking Attachment Curved and Flat Tile Roof Attachment Universal Interface for Other Roof Attachments *Module frame that is compatible with the InvisiMount system required for hardware interoperabllicy. . 5 2015 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER lo;o, and INVISIMOUNT are trademarks or repstered . crademarks of SunPower Corpora uon. All other trademarks are the property of their respective owners. sunpower.com Specifications included in this datasheet are subject to change without notice. Document #509506 Rev 8 InvisiMou-ntOperatingConditions Temperature -40° C to 90° C (-40° F to 194° F) Max. Load 2400 Pa uplift 54.00 Pa downforce InvisiMount Warranties And Certifications Warranties 25 -year product warranty 5 -year finish warranty UL 2703 Listed Certifications Class A fire rating when distance between roof surface and d bottom of SunPower module frame is <- 3.5" Roof Attachment Hardware Refer to roof attachment hardware manufacturer's documentation *Module frame that is compatible with the InvisiMount system required for hardware interoperabllicy. . 5 2015 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER lo;o, and INVISIMOUNT are trademarks or repstered . crademarks of SunPower Corpora uon. All other trademarks are the property of their respective owners. sunpower.com Specifications included in this datasheet are subject to change without notice. Document #509506 Rev 8 DETAIL .INVISIMOUNT. •RACKING _ t_ SOLAR MODULE < . �, J_ ; - •;, <- .r ' END CLAMP i MID CLAMP INVISIMOUNT RAIL- *EACH MID CLAMP GROUNDS THE ` MODULE TO THE RAIL - t 3. .. •' ate. ^'.r-- � •. �... : .. -.. _ C ,- �.. �L -INVISIMOUNT RAIL s - � »• ' " ` .. ..' .. L FOO ,. .. GreenFasten`" GF1 — Product Guide Installation Instructions with Compression Bracket t r 2 5 Consult an engineer or go to www.ecofastensolar.com for engineering data. 3 4a 4b 4c 1. Locate the rafters and snap horizontal and vertical lines to mark the installation position for each GreenFasten flashing. 2. Drill a pilot hole (1/4"diameter) for the lag bolt. Backfill with sealant. EcoFasten Solar recommends an EPDM mastic. 3. Insert the flashing so the top part is under the next row of shingles and pushed far enough up slope to prevent water infiltration through vertical joint in shingles. The leading edge of flashing must butt against upper row of nails to prevent turning when tourqued. See page 2.2 for vertical adjustment when leading edge of flashing hits nails in upper shingle courses. 4. Line up pilot hole with GreenFasten flashing hole. 4a Insert the lag bolt through the EPDM washer, the top compression component bracket (L- 102-3, L-102-6*, SCL-101-3*, Z-101*, Conduit Mount Bracket*) and the gasketed hole in the flashing and into the rafter. 4b Insert the lag bolt through the EPDM washer, the Comp Mount Slide compression bracket and the gasketed hole in the flashing and into the rafter. 4c Insert the lag bolt through the SS wdsher, the third -party bracket, the EPDM bonded washer, the CP -SQ -Slotted compression bracket and the gasketed hole in the flashing and into the rafter. 5. Torque: The range is between 100-140 torque inch -pounds depending on the type of wood and time of year. The visual indicator for proper torque is when the EPDM on the underside of the bonded washer begins to push out the sides as the washer compresses. If using an impact wrench to install the fasteners be careful not to over torque the fastener. You may need to stop and use a ratchet to finish the install. *not pictured. 877-859-3947 EcoFasten Solar' All content protected under copyright. All rights reserved. 7/24/2014 EcoFasten Solar products are protected by the tollowina U.S. Patents: 8,151.522 82 8,153,700 132 8,181,398 132 8,166.713 132 8.146.299 132 8,209.914 82 8.245.454 B2 8.272.174 132 8,225.557 132 2.1 L 2 5 Consult an engineer or go to www.ecofastensolar.com for engineering data. 3 4a 4b 4c 1. Locate the rafters and snap horizontal and vertical lines to mark the installation position for each GreenFasten flashing. 2. Drill a pilot hole (1/4"diameter) for the lag bolt. Backfill with sealant. EcoFasten Solar recommends an EPDM mastic. 3. Insert the flashing so the top part is under the next row of shingles and pushed far enough up slope to prevent water infiltration through vertical joint in shingles. The leading edge of flashing must butt against upper row of nails to prevent turning when tourqued. See page 2.2 for vertical adjustment when leading edge of flashing hits nails in upper shingle courses. 4. Line up pilot hole with GreenFasten flashing hole. 4a Insert the lag bolt through the EPDM washer, the top compression component bracket (L- 102-3, L-102-6*, SCL-101-3*, Z-101*, Conduit Mount Bracket*) and the gasketed hole in the flashing and into the rafter. 4b Insert the lag bolt through the EPDM washer, the Comp Mount Slide compression bracket and the gasketed hole in the flashing and into the rafter. 4c Insert the lag bolt through the SS wdsher, the third -party bracket, the EPDM bonded washer, the CP -SQ -Slotted compression bracket and the gasketed hole in the flashing and into the rafter. 5. Torque: The range is between 100-140 torque inch -pounds depending on the type of wood and time of year. The visual indicator for proper torque is when the EPDM on the underside of the bonded washer begins to push out the sides as the washer compresses. If using an impact wrench to install the fasteners be careful not to over torque the fastener. You may need to stop and use a ratchet to finish the install. *not pictured. 877-859-3947 EcoFasten Solar' All content protected under copyright. All rights reserved. 7/24/2014 EcoFasten Solar products are protected by the tollowina U.S. Patents: 8,151.522 82 8,153,700 132 8,181,398 132 8,166.713 132 8.146.299 132 8,209.914 82 8.245.454 B2 8.272.174 132 8,225.557 132 2.1 L GreenFasten" GF1 - Product Guide 104 11,11A Installation Instructions *Use for vertical adjustment when leading edge of flashing hits nails in upper shingle courses . . Slide flashing up under shingles until leading edge engages nails. Measure remaining distance to adjust shingle �i1•r Mj `W �7 f r. } �l� •,. moi; � . � y .�-.t;TS �'S .�'� �T .j 3. Reinstall flashing with notched area upslope. 4. Position notched leading edge underneath nail heads as shown. je Nails beneath shinqle —J Nails beneath shingle 2. Remove flashing and cut "V" notch at marks where nail shafts engaged leading edge of flashing the distance desired in Step 1. Notch depth not to exceed 2" length by 1/2" width. /#,/. Placement of"V" notch 1 877-859-3947 EcoFasten Solar®All content protected under copyright. All rights reserved. 7/24/2014 2.2 ' EcoFasten Solar products are orotected by the following U.S. Patents: 8.151,522 B2 8.153.700 B2 8.181,398 B2 8,166.713 B2 8,146.299 82 8,209.914 B2 8.245.454 B2 8.272.174 B2 8,225,557 B2 GreenFasten:" GF1 - Product Guide , i �: -Cut Sheets: GF,1. tA 4 ' a � If701 r -SECTION A=A 3 i Al � 111, . ' .. . ` _ a", _ _ � •r,,. � - �' " a 1 877-859-3947 EcoFasten Solar" All content protected under copyright. All rights reserved. 7/24/2014 :{, ' 3.1 ` r EcoFasten. Solar products are protected by the following U.S. Patents: 8.151,522 B2 8,153.700 B2 8.181,398 B2 8.166.713 B2 8,146,299 B2 8,209,914 B2 8.245,454 B2 8,272.174 B2 8.225.557 B2 GreenFasten" GF1 - Product Guide ; . Cut Sheets: GF.1= 812 _ 4X R- - 8 0 T6- ' 1 {I • � Y u yUr �� _ 5 - 5/64 x j 16 t �1 DETAIL A y „•. 4 SCALE: 2:1 If �\ t Finish Options BLK'=Matte Black 'MCL = Mill Finish 1" 877-859-3947 EcoFasten Solar®All content protected under copyright. All rights reserved. 7/24/2014 3.2 • EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 132 8,1.53,700 82 8,181,398 132 8,166.713 132 8,146,299 132 8,209,914 132 8.245.454 B2 8.272.174 132 8.225.557 B2 t a i i GreenFasten•" GF1 - Product Guide t 4 ' Cut Sheets: Bracket Options CF- SQ -Slotted ,�` � � � � the �:. • � >r _ , - .. - - - ' gill I Y .�.� � + �i Cif 1 � - _ . • _ - :. � ... ... - - F� •�, ti — 1.50 .06 .38 , 2.00 • 1.0U r ` +'°•� ''"� p 1.00 _ (160.38±.00 S 0.50 0 0.88±.01 X 82° 2.00 $ xa`tDt#• '•i d" T e, ,• ,T _t.. _h, s.„ �,v r r• 877-859'-39 EcoFasten SolarOAll content protected under copyright. All rights reserved. 7/24/2014 _ 3.3 EcoFasten Solar products are protected by the following U.S. Patents: 8.151,522 132 8,153,700 132 8,181,398 B2 8.166.713 B2 8,146,299 82 8,209,914 82 8.245.454 132 8.272,174 B2 8,225.557 B2 In �^�r � t ,' .. - _- , t .. .f ` ' •- ,, I .. - . GreenFasten'" GF1 =Product Guide k ' ` Cut Sheets: Bracket Options - SCL-101-3" �� yq, i9� ' ,•f.a - .i • use .t _ i R ._. •�I r � � • Via. P _ Y •. y'.• s . -� � � -. t, '. + '` r A. _ `i y �• _x .-2. .T fir- ,. a Y T , w , ♦ r. ` _ r . C ' • • S - • j 'a 46 SERRATIONS ,Rill r .. - r •~ ., r _ .. l k}^5 �111�� }�('1 ��IIf J• �y _ ' �� * F� - y•r '�� a :' (� ••{ ; i ! ., .. • {6}_ 4 ►j tr�,t �1 + -0 i t � � r— +day R1/16" - Tt '1 7/8" / c . Ir1 � R.005 ..... ,__ - R01 �� t�.,�� JJ ,. - .• �— — - —' —1-- - ---� � �- 60.00° Q - - ' • + .006 ,1 3/8.. 1 /8 " �Q .002 7 /'8" X $2° _. DETAIL A SCALE 3:1 877-859-3947 EcoFasten Solar®All content protected under copyright. All rights reserved. 7/24/2014 3.5 r EcoFasten Solar products are protected by the followinq U.S. Patents: 8.151,522 B2 8,153,700 B2 8,181.398 B2 8,166.713 B2 8,146.299 82 8,209,914 B2 8,245.454 B2 8.272.174 B2 8.225,557 B2 GreenFasten-,. F1.- Product Guide - 14 IF ft V �{ f � � "f - x r .r. Cut Sheets: Bracket Options - L-102-3'1 2X.3%8" 46 SERRATIONS LO 1 7/8" L .1 /4" 1/16" R.005 f =R1/16 00 R.010 2X R.01 3/8"-.002,. : °60.00 +006 3/V -.002 0.875+.010 X 82•°= . _ DETAIL A -SCALE 3 1 877-859-3947 EcoFasten Solar" All content protected under copyright. All rights reserved. 7/24/2014 3.6 / EcoFasten Solar products are protected by the following U.S. Patents: 8.151.522 B2 8.153,700 B2 8,181.398 132 8,166,713 B2 8,146.299 B2 8.209.914 B2 8.245.454 B2 8,272.174 B2 8.225.557 B2 N N — 15/16, N ' 1 7/R1. .1 /4" 1/16" R.005 f =R1/16 00 R.010 2X R.01 3/8"-.002,. : °60.00 +006 3/V -.002 0.875+.010 X 82•°= . _ DETAIL A -SCALE 3 1 877-859-3947 EcoFasten Solar" All content protected under copyright. All rights reserved. 7/24/2014 3.6 / EcoFasten Solar products are protected by the following U.S. Patents: 8.151.522 B2 8.153,700 B2 8,181.398 132 8,166,713 B2 8,146.299 B2 8.209.914 B2 8.245.454 B2 8,272.174 B2 8.225.557 B2 AC Circuit Ampacity Calculator Meter #: Customer Name: LANE, LARRY t Location: 48 VISTA ESTATES COURT Orovil,le CA 95965 Wire Note: AC -1 Description: INVERTER TO AC DISTRIBUTION PANEL Wire Calculation 3.84 kWatts VAC Split Voltage Configuration TRUE TL Inverter? 10 Minimum Wire and.Conduit Size based on_'Voltage Drop'and.Ampacity` +`�. 10 Minimum.Ground Size,Based on NEC 20.00 A Minimum Ciruit Breaker/Fuse Size - c' : 10 Actual Ground Size Based on NEC 20.00 A' . 'Ampacity After Derate, 10 Wire Size, Based on Ampacity M 30 A r 0.6613 % of Voltage. Drop 10 Wire Size Based on.Voltage Drop 30 A } 16 A, Circuit Ampacity 1 Factor : ' . 1 Phases ' 0.96 Conditions of Use Derate Factor 16.67 A Minimum Conductor. Ampacity Based on Conditions of Use 20.00 A Minimum Conductor Ampacity Based on 1.25 Rule ` Conditions of Use 0.96 Derate Total 35. °C Temp Coef (ambient + Sunlight)95 °F, 0.96 Derate 35 °C Ambient Temp 95 °F ; none Sunlight Exposure ` 732 °F0 °C Temp adder J` 3 or lessl Number of Current Carrying Conductors 1 1 Derate applied to Temp Coeficient ; Y 8 fl . -11.1 %;.iv,u, _ ii&, v _ _ 2_40V Circuit Voltage 16 A Circuit Amps 1.24 Resistance 40 ft One Way Distance 10 Wire Size 0,.6613 % of Loss Conduit Size (Conduit Fill Can Not be more than 40%) None Conduit Type 0.16 Wire Size Diameter - #N/A Conduit Fill percentage - 1 Conduit Size 0.16 Ground Wire Size Diameter #N/A Conduit Internal Diameter 600 V System Voltage - THW VN-2 Wire Type - -� / ._ .'f'} i.. • r •t . ' �,. r•J• ..k- ..- r . .. as ,.1' , .♦ ', - •' �k- ,• ..- r