Loading...
HomeMy WebLinkAboutB17-1980 021-240-021DEVELOPMENT SERVICES P. 4 BUTTE'COUNTY AREA DEPARTMENT OF DEVELOPMENT SERVICES S 1 INSPECTION CARD MUST BE ON JOB SITE 24 Hour Inspection Line (IVR) : 530.538.4365 (Cut off time. for inspections is 3pm) Development Services cannot guarantee inspections on the date req Et_ested Office_ 530.538.7601 Fax- 530 538 77R5 www Rntte.Cnrnnty netklrlc Permit No:'B 17-1980 Issued: 8/30/2017 ' APN: 021-240-021 F Address: 187 LITTLE AVE, GRIDLEY Owner: Gilbert Correa ? Permit Type: SOLAR ROOF -RES Description: Installation of solar panels on existing residenti ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING c r Insvection Tyne IVR INSINSP DATE Setbacks 131 Foundations / Footings III Pier/Column Footings 122 Eufer Ground 216 Masonry Grout . 120 Setbacks 131 Do Not Pour Concrete Until Above are Signed Pre -Slab 124 Gas Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing 149 Underfloor Ducts 319 Shear Transfer 136 Under Floor Plumbing 412 Under Slab Plumbing 411 Blockin nder inin 612 Tiedown/Soft Set System 611 Do Not Install Floor Sheathing or Slab Until Above Signed ShearwallB.W.P.-Interior 134 ShearwallB.W.P.-Exterior 135 Roof Nail/Drag Trusses 129 Manometer Test 605 Do Not Install Siding/Stucco or Roofing Until Above Signed Rough Framing 153 Rough Plumbing 406 Rough Mechanical 316 ' Rough Electrical 208 4 -Way Rough Framing 128 Gas Piping House 403 Gas Test House 404 Shower Pan/Tub Test 408 Do Not Insulate Until Above Si ned . Permit Final 802 Electrical Final 803, Mechanical Final 809 Plumbing Final 813 Fire Sprinkler Test or Final 702. Swimmin2 Pools Inspection Type Permit IVR INSP DATE T -Bar Ceiling 145 Stucco Lath 142 Swimmin2 Pools Setbacks 131 Pool Plumbing Test 504 Gas Test 404 Pre-Gunite - 506 Pre -Deck 505 Pool Fencing/Alarms/Barriers 503 Pre -Plaster 507 Manufactured Homes Setbacks 131 Blockin nder inin 612 Tiedown/Soft Set System 611 Permanent Foundation System 613 Underground Electric 218 Sewer 407 Underground Water 417 Manometer Test 605 Continuity Test 602 Ski rtin Ste s/Landin s 610 Coach Info Manufactures Name: Date of Manufacture: Model Name/Number: Serial Numbers: Length x Width: Insignia- nsi nia- Public Works Final 538.7681 Fire De artment/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final **OJECT I L i •ZN. *Project Final is a Certificate of Occupancy for (Residential Only) - PERMITS BECOME NULL AND VOID 1 YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A 1,YEAR RENEWAL 30 DAYS PRIOR TO EXPIRATION y 4801 N UNIVERSITY AVE, #900 - - � �• ,. PROVO, UT 84604 • - T 2 (888)781-7074 F S { ` • • y .5A . •, * .. ' .. e 1 '. �` .fiyk:�{ai ��• ` as �,! 't - ..• y 1 . - - • �t � f •7. `' V . -i sir �••• r u •Y • a , - r •. [ - , ' ',`-• /. + ` •J n - 1 • ~ C +t ' ,� ^• � + ` j a' MAP OF LOCATION LICENSED ELECTRICAL CONTRACTOR COMPANY:' • ,. - }.. ,� ,- t - ION DEVELOPER LLC . �•, •• ., •. - i si CLASSIFICATION: • - ,. _• •� • LICENSE NUMBER: AHTHOWZEDC YrRAC OR:. 1027027 EXPIRATION: I� t 5/31/2019 r r - , `r _ �fi^ SYSTEM SIZE: 10.08 kW DC 8.28 kW AC 11 36 MODULES { , ` DATE: 8%24/2017 .. •• . 4j 7 , x �: , :_..r' �' ` ^'I .•. , , / , . , , - DRAWN BY: CHRIS BAILE 5 L• ' ., ADDITIONAL NOTES: f SCOPE OF WORK: + : J THE SYSTEM CONSISTS OF A 10.08 KW DC (8.28 KW AC) ROOF -MOUNTED PHOTOVOLTAIC POWER SYSTEM OPERATING IN �+ - PARALLEL WITH THE UTILITY GRID. THERE ARE (36) TRINA • ' �' - ° �' TSM-280DD05A.05(II) MODULES AND (3 6) ENPHASE IQ6-60-27US MICRO -INVERTERS, MOUNTED ON THE BACK OF EACH PV MODULE, CONNECTING TO THE UTILITY GRID THROUGH THE •'' UPGRADE MAIN LOAD CENTER: ELECTRICAL MODIFICATIONS ° WILL BE MADE TO THE MAIN LOAD CENTER. INTERCONNECTION METHOD: , LOAD SIDE BREAKER { SHEET: ROOF MATERIAL: COMP SHINGLE COVER ALL CONDUIT WILL BE PAINTED TO MATCH THE EXISTING STRUCTURE. _ PROJECT WILL COMPLY WITH THE 2016 CRC, 2016 CEC, 2016 �. PV 1.0 �`• CBC, AND 2016 CFC, 2015 -IRC, 2014 NEC, 2015 IBC, 2015 IFC. AC DISCONNECT LOCATED NEXT TO OR WITHIN.10 FEET OF MAIN SERVICE PANEL(LINE OF SIGHT MAINTAINED).- , y ®- CIRCUIT I ®- CIRCUIT 2 M_CIRCUIT 3 ti (36) PV MODULES WITH MICRO -INVERTERS. MICRO -INVERTERS HAVE BUILT-IN RAPID SHUTDOWN IN COMPLIANCE WITH CEC 690.12 UTILITY METER LOCATION MAIN SERVICE LOCATION/ POINT OF INTERCONNECTION AC DISCONNECT SWITCH COMBINER PANEL ENVOY IQ (DRAWS 0.22 AMPS) SCALE: NION 4801 N UNIVERSITY AVE, #900 PROVO, UT 84604 (888)781-7074 O > U ¢U 4 w a LICENSED ELECTRICAL CONTRACTOR COMPANY: ION 6EVELOPER LLC CLASSIFICATION: C 10 AUTHORIZED CONTIU R: 1027027 LICENSE NUMBER: EXPIRATION: 5/31/2 5/31/2011 9 SYSTEM SIZE: 10.08 kW DC 8.28 kW AC 36 MODULES DATE: 8/24/2017 DRAWN BY: CHRIS BAILS SHEET: SITE PLAN PV 2.0 PV MODULES AND MICRO -INVERTERS. MICRO -INVERTERS HAVE BUILT-IN RAPID SHUTDOWN IN COMPLIANCE WITH CEC 690.12 ROOF SECTION DATA ROOF SECTION A B C D E F G H MODULES . 36 TILT' 18 AZIMUTH 270 ,SOLAR ACCESS AVG. 77.00% SCALE: 10N 4801 N UNIVERSITY AVE, #900 PROVO, UT 84604 (888)781-7074 00 O � � U ¢v H a� a C7 LICENSED ELECTRICAL CONTRACTOR COMPANY: ' ION DEVELOPER LLC CLASSIFICATION: C IO AU 110RIZRD COWRACfOR: LICENSE NUMBER: IGL�k't�" 1027027 EXPIRATION: ' 5/31/2019 SYSTEM SIZE: 10.08 kW DC 8.28 kW AC 36 MODULES DATE: 8/24/2017 DRAWN BY: CHRIS BAILE ADDITIONAL NOTES: FIRE CODE OFFSET 2" X 6" TRUSS SYSTEM 24" ON CENTER CANTILEVERS WILL BE NO MORE THAN 24" ATTACHMENT POINTS WILL BE NO MORE THAN 6' APART, STAGGERED SHEET: ROOF PLAN PV 3.0 WEATHER DATA HIGH TEMP, 2% AVG. 38 °C MIN DESIGN TEMP -3 OC GROUND SNOW LOAD 0 psf WIND SPEED 110 mph MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION FROM 2009 ASHRAE HANDBOOK- FUNDAMENTALS 1. HIGH TEMPERATURE 2% AVERAGE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION , MOST SIMILAR TO INSTALLATION LOCATION ' 2. MINIMUM DESIGN TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION ' MOST SIMILAR TO INSTALLATION LOCATION 3.' ALTERNATE POWER SOURCE PLACARD SHALL BE PERMANENTLY °� ATTACHED TO A/C DISCONNECT. 4. ELECTRICAL INSTALL SHALL COMPLY WITH 2016 CALIFORNIA ELECTRICAL CODE (INCLUDING AN "ALTERNATE POWER SOURCE PLACARD') ' 5. 'ALL SOLAR MODULES, EQUIPMENT, AND METALLIC COMPONENTS SHALL BE BONDED' 6. IF. THE EXISTING MAIN SERVICE DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE, IT IS THE PV CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE 7. EACH MODULE SHALL BE GROUNDED PER MANUFACTURER INSTRUCTIONS AND APPROVED METHODS 8. PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING VENTS, MECHANICAL EQUIPMENT, MECHANICAL VENTS, OR BUILDING ROOF VENTS IN ACCORDANCE WITH CPC 901.1, CPC 906, AND CMC 304. 9. CONNECTORS THAT ARE NOT READILY ACCESSIBLE AND THAT ARE USED IN THE CIRCUITS OPERATING AT OR OVER 30V AC OR DC SHALL REQUIRE A TOOL FOR OPERATING. AND ARE REQUIRED TO BE MARKED "DO NOT DISCONNECT UNDER LOAD" OR "NOT FOR CURRENT INTERRUPTING" 10. THIS SYSTEM IS IN FULL COMPLIANCE WITH THE CALIFORNIA FIRE CODE FOR PHOTOVOLTAIC INSTALLATION AND ARTICLE ".690 OF THE NATIONAL ELECTRIC CODE (NEC, / NFPA 70) 11. BUILDING CONSTRUCTION TYPE: TYPE V 12. BUILDING OCCUPANCY TYPE: R3 ION,, 4801 N UNIVERSITY AVE, #900 PROVO, UT 84604 (888)781-7074 LICENSED ELECTRICAL CONTRACTOR COMPANY: ION DEVELOPER LLC CLASSIFICATION: C10 LICENSE NUMBER: Al ORIZEDCOMRA M- I EXPIRATION: 5/31/2 5/31/2011 9 SYSTEM SIZE: 10.08 kW DC 8.28 kW AC 36 MODULES DATE: 8/24/2017 . DRAWN sY: CHRIS BAILE ADDITIONAL NOTES SHEET: LOCATION NOTES PV 4.0 U ¢� W a� °� LICENSED ELECTRICAL CONTRACTOR COMPANY: ION DEVELOPER LLC CLASSIFICATION: C10 LICENSE NUMBER: Al ORIZEDCOMRA M- I EXPIRATION: 5/31/2 5/31/2011 9 SYSTEM SIZE: 10.08 kW DC 8.28 kW AC 36 MODULES DATE: 8/24/2017 . DRAWN sY: CHRIS BAILE ADDITIONAL NOTES SHEET: LOCATION NOTES PV 4.0 SHEET: MOUNTING PV 5.0 ION 4801 N UNIVERSITY AVE, #900 PROVO, UT 84604 (888)781-7074 MSI ALPHA+ RAIL 00 rll L -FOOT v . W : ECOFASTEN COMP e • a ` SHINGLE MOUNT. 6111VIAX ' �,F" ;�•%� �^ LICENSED ELECTRICAL CONTRACTOR . ��,�•{,;:;:y,✓' . ���..;,;•,%" COMPANY: ION DEVELOPER LLC CLASSIFICATION: r,} / / C 10 AViHOR1ZED CONTMCrOR: LICENSE NUMBER:. 1027027 EXPIRATION: 5/31/2019 SYSTEM SIZE: 10.08 kW DC 8.28 kW AC PLYWOOD 36 MODULES J COMP DATE. 8/24/2017 °`�"'" BY: CHRIS BAILEY SHINGLE ADDITIONAL NOTES: . ROOF TILT(S): 18° TRUSS SHEET: MOUNTING PV 5.0 ION 4801 N UNIVERSITY AVE, #900 PROVO, UT 84604 (888)781-7074 THIS PV SYSTEM WILL HAVE THE FOLLOWING MARKINGS 1 -- MATERIALS USED FOR MARKINGS WILL BE WEATHER RESISTANT. THE UNDERWRITERS LABORATORIES MARKING v AND LABELING SYSTEM 969 (UL969) WILL BE USED AS STANDARD 'PO DETERMINE WEATHER RATING. 2:-- MARKING STATING "CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED" WILL BE PLACED AT THE MAIN SERVICE DISCONNECT. 3 -- MARKING STATING "WARNING: PHOTOVOLTAIC POWER SOURCE" WILL BE PLACED ALONG DIRECT CURRENT CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES, AND JUNCTION BOXES. 4 -- THE MARKING WILL BE MADE TO THE FOLLOWING SPECIFICATIONS: •. RED BACKGROUND WHITE LETTERING • MINIMUM 3/8" LETTER HEIGHT • ALL CAPITAL LETTERS • ARIAL OR SIMILAR FONT, NON -BOLD • REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (DURABLE ADHESIVE. MATERIALS MAY MEET THIS REQUIREMENT) 5 -- MARKING WILL BE PLACED ON ALL INTERIOR AND EXTERIOR CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES, AND JUNCTION BOXES TO ALERT THE FIRE SERVICE TO AVOID CUTTING THEM. MARKINGS WILL BE PLACED ON ALL EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES EVERY 10 FEET, AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS AND ALL DC COMBINER AND JUNCTION BOXES. LICENSED ELECTRICAL CONTRACTOR COMPANY: ION DEVELOPER LLC CLASSIFICATION: C 10 LICENSENUMBER: AUTHORIZEDCOITMC10R: EXPIRATION: 5/31/2 (� 5/31/2011 9 SYSTEM SIZE: 10.08 kW DC 8.28 kW AC 36 MODULES DATE: , 8/24/2017 DRAWN BY: CHRIS BAILS ADDITIONAL NOTES: SHEET: SYSTEM MARKINGS PV 6.0 I— , 00 O >° U ¢� (� a LICENSED ELECTRICAL CONTRACTOR COMPANY: ION DEVELOPER LLC CLASSIFICATION: C 10 LICENSENUMBER: AUTHORIZEDCOITMC10R: EXPIRATION: 5/31/2 (� 5/31/2011 9 SYSTEM SIZE: 10.08 kW DC 8.28 kW AC 36 MODULES DATE: , 8/24/2017 DRAWN BY: CHRIS BAILS ADDITIONAL NOTES: SHEET: SYSTEM MARKINGS PV 6.0 I— , THIS PV SYSTEM WILL. HAVE THE FOLLOWING MARKINGS: PHOTOVOLTAIC DC DISCONNECT CEC 690.14 (C)(2) LOCATED ON THE DC DISCONNECT PORTION OF THE INVERTER (FOR STRING INVERTERS, NOT APPLICABLE TO MICRO -INVERTERS) PHOTOVOLTAIC AC DISCONNECT RAPID SHUTDOWN SWITCH CEC 690.14 (C(2) LOCATED ON THE AC DISCONNECT PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN ° MICRO -INVERTERS SERVE AS RAPID SHUTDOWN DEVICES AT MODULE LEVEL CEC 690.56 (B) & (C) LOCATED ON THE AC DISCONNECT AND ALL JUNCTION BOXES AT ARRAY LEVEL PHOTOVOLTAIC SYSTEMS AC SYSTEM SPECIFICATIONS SYSTEM SIZE: KW COMBINED OPERATING RATING: AMPS RATED OUTPUT VOLTAGE: VAC CEC 690.17 & CEC 690.54 LOCATED ON MAIN SERVICE PANEL WARNING: DUAL POWER SOURCES THIS EQUIPMENT FED BY MULTIPLE SOURCES SECOND SOURCE IS PHOTOVOLTAIC SYSTEM RATED AC OUTPUT CURRENT AMPS AC NORMAL OPERATING VOLTAGE VOLTS CEC 690.54 & CEC 705.12(D)(7) PLACE ON MAIN SERVICE PANEL AND ON SOLAR PV COMBINER PANELBOARD PV SYSTEM AC DISCONNECT SECOND SOURCE IS PHOTOVOLTAIC SYSTEM RATED AC OUTPUT CURRENT AMPS AC NORMAL OPERATING VOLTAGE VOLTS CEC 690.54 PLACED NEXT TO THE SOLAR PV BREAKER AND ON AC DISCONNECT WARNING: PHOTOVOLTAIC POWER SOURCE CRC R331.2 PLACED ALONG DIRECT CURRENT CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES, AND JUNCTION BOXES WARNING: ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION CEC 690.17 & CEC 690.54 PLACED ON OR ADJACENT TO THE AC DISCONNECT AND DISCONNECTING MEANS (SOLAR PV BREAKER) WARNING: ELECTRIC SHOCK HAZARD GROUNDED CONDUCTORS MAY BECOME UNGROUNDED AND ENERGIZED IF A GROUND FAULT IS INDICATED ' CEC 690.5 (C) PLACED ON ALL INVERTERS AND JUNCTION BOXES, OR PLACED NEAR THE GROUND -FAULT INDICATOR AT A VISIBLE LOCATION - WARNING: ELECTRIC SHOCK HAZARD MICRO -INVERTER PHOTOVOLTAIC SYSTEM DC CONDUCTORS OF PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED CEC 690.35 (F) ` PLACED ON ALL INVERTERS, JUNCTION BOXES AND SOLAR PV COMBINER PANELBOARD WARNING: INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE CEC 705.12 (131)(7) PLACED NEXT TO THE SOLAR PV BREAKER ON THE MAIN SERVICE PANEL, AND ON THE SOLAR PV COMBINER PANELBOARD r .ION., 4801 N UNIVERSITY AVE, #900 PROVO, UT 84604 (888)781-7074 �I LICENSED ELECTRICAL CONTRACTOR COMPANY: ION DEVELOPER LLC CLASSIFICATION: • C 10 LICENSE NUMBER: ^'oR¢r:DcomAcroR: J J GL S EXPIRATION: 5/31/2 li//[]//(�,,1 5/31/2011 9 SYSTEM SIZE: 10.08 kW DC 8.28 kW AC 36 MODULES DATE: 8/24/2017 DRAWN BY: CHRIS BAILE ADDITIONAL NOTES SHEET: SYSTEM MARKINGS PV 7.0 PV MODULE SPECIFICATIONS A TSM-280DD05A.08(II) DESIGN WILL UTILIZE INTEGRATED MODULE MAKE AND MODEL 280 WATTS GROUNDING BETWEEN PV MODULES MAXIMUM POWER (DC) 31.7 VOLTS AND RACKING. MAX POWER -POINT VOLTAGE (VMPP) 8.84 AMPS ENVOY-S METER POWERED BY PV39 VOLTS SYSTEM, PROTECTED BY 15A OCPD MAX POWER POINLTAGE (VO )PP> AMPS LOCATED IN 125A COLLECTION' OPEN CIRCUIT VO 9.35 PANEL. SHORT CIRCUIT CURRENT (ISC) -0.29 %/OC PERMANENT PLAQUES LABELED TEMPERATURE COEFFICIENT VOC 1000V DC (UL) "pV RAPID SHUTDOWN1, WILL BE MAXIMUM SYSTEM VOLTAGE INSTALLED ADJACENT TO THE VISIBLE LOCKABLE IN /C DI BOXENS AND- ON ARRA PV CIRCUIT 1: 11 MODULES/PARALLEL • COMBINER PANEL 125A/240V ENVOY IQ • (DRAWS 0.22 AMPS) 15A PV CIRCUIT 2: 10 MO /PARALLEL 15A 15A 20 A PV CIRCUIT 3: 15 MODULES/PARALLEL JUNCTION BOX 1, . LOCATED ON ROOF B A GROUNDING WIRE ADDITIONAL ROOFTOP DISCONNECT NOT REQUIRED. ENPHASE T DISC NVERTER CABLE CONNECTORS ME PV MODULE WITH ET DONNECT LIES WITH ED REQUIREMENTS. CEC 690.33 MICRO -INVERTER INVERTER COMPUIREMENTS RAPID SHUTDOWN REQ IN CEC 690.12. INVERTER SPECIFICATIONS ON ASE PECIFICA EOASE IQ6-60-2-US INVERTER MAKE AND MODEL 230 WATTS 4801 N UNIVERSITY AVE, #900 RATED OUTPUT POWER (AC) 240 VOLTS • PROVO, UT 84604 (888)791-71074 NOMINAL OUTPUT VOLTAGE (AC) 0.96 AMPS MAX OUTPUT CURRENT (AC) 48 VOLTS MAX INPUT VOLTAGE (DC) 15 AMPS MAX INP CURRENT (DC) 20 AMPS MAX OCPD RATING (AC) 16 NUMBER OF PANELS PER CIRCUIT a _ kllU VISIBLE LOCKABLE "KNIFE" w A/C DISCONNECT 60A/240V a/ a 200 A00 rH� 45 UPGRADE 240V/225A BUSBAR RATED - LOAD -CENTER (NON- FURTHEST POSIT .CENTER FED) PANEL. IN BREAKER WILL AWAY FROM DISCONNECT. AS OUTLINED SCHEDULE AC PHOTOVOLTAIC SYSTEM RATINGS 34.56 AMPS MAX AC OPERATING CURRENT 240 VOLTS MAX AC OPERATING VOLTAGE *ROMEX WILL BE RAN THROUGH THE ATTIC WHERE POSSIBLE . RIF MORE TRAY BECONDUCTORS, INS DA LED WITH NO MORE THAN 12 RACEWAYS MAY UCTORS IN EACH RACEWAY OTHERWISE, #9 WIRE AND 3/4 CONDUIT MUST E USED WHERE APPLICABLE AND TAG CONDUCTOR TYPE ENPHASE ENGAGE CABLE (USE -2) A BARE COPPER (EGC/GEC) TIIWN 2 OR NM (ROMEX) " B THWN72 OR NM (ROMEX) (EGC/GEC) THWN-2 OR NM (ROMEX) CTHWN-2 OR NM (ROMEX) (EGC/GEC) RACEWAY AND CONDUCTOR RACEWAY / CABLE TYPE MINIMUM WIRE SIZE # OF CONDUCTORS 2 USE -2 / FREE AIR 12 BARE / FREE AIR 1 12 10 6 EMT/ROMEX l 8 8 3 EMT/ROMEX l 8 MINIMUM CONDUIT SIZE N/A 3/4" 11 3/4" I ELECTRICAL CONTRACTOR Y:VELOPER LLCCATION:O AIMIORIZED CONTRACTOR; NUMBER: ION027027 ION:1/2019 M SIZE: I0.08 kW DC 8.28 kW AC 36 MODULES : 8/24/2017 N BY: CHRIS BAILE 1 -LINE EL 1.0 1. THE.ENPHASE M250, M215 (M215-60-2LL-SXX—IG), AND C250 FOURTH GENERATION MICROINVERTERS MEET THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE ARTICLE 690.35 FOR UNGROUNDED- PHOTOVOLTAIC POWER SYSTEMS. NEC 690.35 ALLOWS FOR PHOTOVOLTAIC POWER SYSTEMS TO BE INSTALLED WITH UNGROUNDED PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUITS. SYSTEMS THAT MEET THE REQUIREMENTS OF NEC 690.35 ARE EXEMPT FROM THE SYSTEM GROUNDING REQUIREMENTS OF NEC 690.41 SYSTEM GROUNDING. 2. NEC ARTICLE 690.43 EQUIPMENT GROUNDING SPECIFIES THAT ALL EXPOSED NON-CURRENT—CARRYING METAL PARTS OF PV .MODULE FRAMES, ELECTRICAL EQUIPMENT, AND CONDUCTOR ENCLOSURES SHALL BE PROVIDED WITH EQUIPMENT GROUNDING. 690.43(C) STRUCTURE AS EQUIPMENT GROUNDING CONDUCTOR ALLOWS FOR 4 EQUIPMENT TO BE USED AS THE EQUIPMENT GROUNDING CONDUCTOR IN ,1. A PHOTOVOLTAIC SYSTEM. SPECIFICALLY, "DEVICES LISTED o' AND IDENTIFIED FOR GROUNDING THE a: METALLIC FRAMES OF PV MODULES OR OTHER EQUIPMENT SHALL BE PERMITTED TO BOND THE EXPOSED METAL SURFACES t OR OTHER EQUIPMENT TO {MOUNTING SURFACES." THE DEVICES LISTED AND IDENTIFIED FOR GROUNDING THE EQUIPMENT MAY BE STAND-ALONE GROUNDING COMPONENTS OR UL -2703 LISTED MOUNTING HARDWARE. IN AN ENPHASE MICROINVERTER SYSTEM, IF THE MICROINVERTERS AND MODULES. ARE BONDED TO THE RACKING j ASSEMBLIES WITH THE USE OF LISTED AND APPROVED GROUNDING CLIPS OR GROUNDING COMPONENTS; THE EQUIPMENT GROUNDING CONDUCTOR PROVIDED TO THE MICROINVERTERS THROUGH THE ENPHASE ENGAGE CABLE MAY ALSO. BE USED TO GROUND THE OTHER PHOTOVOLTAIC SYSTEM COMPONENTS. ION. 4801 N UNIVERSITY AVE, #900 PROVO, UT 84604 (888)781-7074 LICENSED ELECTRICAL CONTRACTOR COMPANY: ION DEVELOPER LLC CLASSIFICATION: C IO AUTHORIZED CONTRACMR: LICENSE NUMBER:l`�'��'"" 1027027 EXPIRATION: 5/31/2019 SYSTEM SIZE: 10.08 kW DC 8.28 kW AC 36 MODULES DATE: 8/24/2017 DRAWN BY: CHRIS BAILE ADDITIONAL NOTES ELECTRICAL NOTE EL 2.0 U ¢U W, a W H -I C7 LICENSED ELECTRICAL CONTRACTOR COMPANY: ION DEVELOPER LLC CLASSIFICATION: C IO AUTHORIZED CONTRACMR: LICENSE NUMBER:l`�'��'"" 1027027 EXPIRATION: 5/31/2019 SYSTEM SIZE: 10.08 kW DC 8.28 kW AC 36 MODULES DATE: 8/24/2017 DRAWN BY: CHRIS BAILE ADDITIONAL NOTES ELECTRICAL NOTE EL 2.0 60 CELL = MONOCRYSTALL`I'N'E MODUILE 270-2:95W POWER -- - POWER OUTPUT RANGE Maximize limited space with top-end efficiency •'Up to 180 W/mz power density • Low thermal coefficients for greater energy production at high operating temperatures 1 8...'0710 MAXIMUM EFFICIENCY Highly reliable due to stringent quality control - 5 Over 30 in-house tests (UV, TC, HF, and many more) z In-house testing goes well beyond certification requirements • 100% EL double inspection POSITIVE POWER TOLERANCE - As a leading global manufacturer of Certified to withstand challenging environmental next generation photovoltaic products, conditions we believe close cooperation with 2400 Pa wind load our partners is critical to success. With 5400 Pa snow load local presence around the globe, Trina is able to provide exceptional service 35 mm hail stones at 97 km/h Jo each customer in each market and supplement our innovative, reliable products with the backing of Trina as a• strong, 'bankable partner. We are committed to building strategic, mutually beneficial collaboration with installers, developers, distributors and - other partners as the backbone of our shared success in driving Smart Energy Together. TrinaSolar Llmlted Comprehensive products and system certificates www.trinasolar.com — . IEC 61215/ IEC 61730/ UL 1703/ IEC 61701/IEC 62716 LINEAR PERFORMANCE WARRANTY - •. ISO 9001: Quality Management System 10 Year Product Warranty. iS Year Linear Power Warranty ISO 14001: Environmental Management System - "" ISO 14064: Greenhouse Gases Emissions Verification OHSAS 18001: Occupation Health and Safety Management System PY CYCLE LISTED - `W Trinasolar Smart Energy Together .. THE ALLMAX°pLUS' MODULE PRODUCTS POWER RANGE ELECTRICAL DATA (STC) TSM-DD05A.08(11) 275-295W TSM-DD05A.05(11) 270-29OW DIMENSIONS OF PV MODULE unit:mm/Inches neuon Box 4.09.12 w xole Nameplate o A L A a e c 6.04.3 ctoeading Hole 12 -Drain H°le a 18017. 992/39.1 Back Yew S Bean Sealant II/0.43 laminate • Fane 35/1.38 AA i -V CURVES OF PV MODULE(295W) a TEMPERATURE RATINGS MAXIMUM RATINGS Peak Power Watts-Pt4,5x (Wp)• 270 27$ 1 280 T 285' 290 295 Power Output Tolerance -P -x (W) 28.9 ! 29.2 0-+5 29.6 29.9 30.2 Maximum Power Voltage-VMrr (V) 31.2 31.4 31.7 31.8 32.2 32.5 Maximum Power Current-lwp (A) t 8.66 8.76 8.84 8.97 9.01 9.08 Open Circuit Voltage-Voc (V) 38.4 38.7 39.0 39.3 39.5 39.7 Short Circuit Current-hc (A) 9.18 9.26 9.35 9.45 9.50 9.55 Module Efficiency r)m (�) 16.5 16.8 17.1 17.4 17.7 18.0 STC: Irradlance 1000 W/m'. Cell Temperature 25°C. Air Mass AM 1.5. *Test toleronce: t39. ELECTRICAL DATA (NOCT) ' Maximum Power-P-x(Wp) 201 205 209 212 216 220 Maximum Power Voltage-Vwp (V) 28.9 ! 29.2 29.4 29.6 29.9 30.2 Maximum PowerCurrent-IMrr (A) 6.96 7.02 7.107.17 Connector 7.23 7.28, Open Circuit voltage-Voc (V) 35.7 36.0 36.3 36.6 36.7' 36.9 Short Circuit Current-Isc (A) 7.41 7.48 7.55 7.63 7.67 7.71 ' NOCT: Irradiance at 800 W/m', Ambient Temperature 20°C. Wind Speed I m/s. ( MECHANICAL DATA Solar Cells Monocrystolline 156 x.156 mm (6 inches) Cell Orientation 60 cells (6 x 10) Module Dimensions 1650 x 992 x 35 mm (65.0 x 39.1 x 1.38 inches) Weight 18.6 kg (41.0 Ib) Glass 3.2 mm (0.13 inches), High Transmission, AR Coated Tempered Glass Backsheet White (DD05A.08(11)); Black (DD05A.05(11)) Frame Black (DD05A.08(IQ, DD05A.05(11)) J -Box IP 67 or IP 68 rated Cables Photovoltaic Technology Cable 4.Omm2 (0.006 inches'), 1000 mm (39.4 inches) Connector MC4 Compatible or Amphenol H4/UTX Fire Type Type 1 or Type 2 • Temperature Coefficient of I' At e Temperature Coefficient of Voc . - 0.29%/°C Temperature Coefficient of Isc 0.05%/°C r s 5 a 4 3 _ , aow a Nominal Operating Cell 44 -Cit 2°C) Temperature (NOCT) Temperature Coefficient of I' At -0.39%/°C Temperature Coefficient of Voc . - 0.29%/°C Temperature Coefficient of Isc 0.05%/°C 0 0 5 le 15 M 25 m 3s 40 45 V bwm WARRANTY P -V CURVES OF PV MODULE(295W) 10 year Product Workmanship Warranty n. 000 250 4 zW Lgg ,so . i ,m o 25 year Linear Power Warranty (Please refer to product warranty for details) PACKAGING CONFIGURATION Modules per box: 30 pieces Modules per 40' container: 840 pieces Operational Temperature -40-+85°C Maximum System Voltage 1000V DC (JEC) 1000V DC (UL) Max Series Fuse Rating 15A �l 0 z wl 0 5 10 is . . M rs 10 3S 40 Is vaw°yv1 � TrinaSOlal CAUTION: READ SAIAND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. @2016 Trina Solar Limited. d. All rights reserved. Specifications Included in this datasheet are subject to change without notice. Smart Energy Together �t • Productive and Reliable • Optimized for high powered 60 -cell and 72 - cell* modules • More than a million hours of testing • Class II double -insulated enclosure Smart Grid Ready • Complies with fixed power factor, voltage and frequency ride -through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles * The IQ 6+ Micro is required to support 72 -cell modules n ENPHASE. _ Data Sheet - Enphase Micromverters 4 Enphase The high-powered smart grid -ready Enphase IQ 6 Micro' and Enphase IQ 6+ Micro"" Q 6 and Q 6'+:. dramatically simplify the installation process while ;. achieving the highest efficiency for module -level .. Micro':. nverters:. power electronics. Part of the Enphase IQ System, the IQ 6 and IQ 6+ Micro integrate seamlessly with the Enphase IQ Envoy"', Enphase Q Aggregator"", Enphase IQ Battery"', and the Enphase Enlighten"' monitoring and analysis software. The IQ 6 and IQ 6+ Micro extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing. Enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install • Lightweight and simple • Faster installation with improved two -wire cabling Built-in rapid shutdown compliant (NEC 2014) Productive and Reliable • Optimized for high powered 60 -cell and 72 - cell* modules • More than a million hours of testing • Class II double -insulated enclosure Smart Grid Ready • Complies with fixed power factor, voltage and frequency ride -through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles * The IQ 6+ Micro is required to support 72 -cell modules n ENPHASE. Enphase IQ 6 and IQ 6+ Microinverters INPUT DATA (DC) IQ6-60-2-US AND IQ6-60-5-US IQ6PLUS-72-2-US AND IQ6PLUS-72-5-US Commonly used module pairings' 195W -330W+.235 W 400 W + _ Module compatibility 60 -cell PV modules only 60 -cell and 72 -cell PV modules r Maximum input DCvoltage - 48V 62V ' Peak power tracking voltage T 27V -37V T ^ - 27 V - 45 V 3 Operating range 16 V 48 V _ - 16V -62V - w. Min/Max start voltage 22 V / 48 V 22V/62V Max.DCshort circuit currentmod (ule Isc) _5 A 1 Y l w` ' J� ry - 1.5 AY Overvolta9 ._ a class DC port II II p _-_ _._ _ __- _ ._ - _ _-0-A - DC port backfeed under single fault � � 0 A V .w F -�` '_0 A_w ^;_ � '• ' PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ6-60-2-US AND IQ6-60-5-US IQ6PLUS-72-2-US AND IQ6PLUS-72-5-US Peak output power 1240 VA 290 VA Maximum continuous output power 230 VA 280 VA t Nominal voltage/range' - _ 240 V/ 211-264 V- - _208`V(14))/i8_3-224V', _246V/2111 -264\t 208 V (1m) / 183-229 V Nominal output current 0.96 A 1.11 A 1.17 A T 1.35 A Nominal frequency' _ 60 Hi 7- - 60 Hz� Extended frequency range 47 - 68 Hz r47 - 68 Hz r Power factor at rated power f _ 1.0 ' — ___ - - -` - ' 1.0 - - - _ _' Maximum units per 20 A branch circuit 16 (240 VAC) 13 (240 VAC) 14 (single-phase 208 VAC) 11 (single-phase 208 VAC) Overvoltage class AC port _ _ AC port backfeed under single fault ~ 0 A 0 A Power factor (adjustable) 0:7 leading ... 0.71agging .• 0.7 leading ... 0.7 lagging EFFICIENCY @240 V @208 V (10) @240 V @208 V (10) CEC weighted efficiency 97.0% 96.5% 97.0% 96.5% MECHANICAL DATA 1 Ambient temperature range 40°C to +650C.. _ Relativehumidityrange •4_%to100%(condensing) Connector type MC4 or Amphenol.H4 UTX Dimensions (WxHxD) 219 mm x 191 mm x 37.9 mm (without bracket) _ Weight._ Cooling - - - Natural convection- No fans r 'Approved for wet locations • - Yes -• Pollution degree -� + - PD3' f Environmental category / V—e posure rating FEATURES Communication Power line _ Monitoring yEnlighten Manager and MyEnlighten monitoring options Compatible with Enphase IQ Envoy ComplianceUL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES 0003 Clas's B, j CAN/CSA-C22.2 NO. 107.1-01 I A This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC -2014 and I NEC -2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for, AC -and DC conductors, when installed according nlanufacturer's instructions---,-, : 1. No enforced DC/AC ratio. See the compatibility calculator at enphase.com/en-us/support/module-compatibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility. To learn more about Enphase offerings, visit enphase.com @ 2017 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. E N P H AS E. 2017-05-01