Loading...
HomeMy WebLinkAboutB17-1988 047-670-0651 _ t BUTTE'COUNTY AREA ,K • iL_ .M DEPARTMENT OF DEVELOPMENTSERVICES --INSPECTION CARD MUST BE ON JOB SITE ' A. 124 Hour -Inspection Line (IVR) : 530538.4365 f (Cut off time for.inspections is 3pm) - evlopment Services cannoguarantee inspections on the date requested ' • VELOPMENT SERVICES p Det d DE ,. _ �•.. - - - Office:` 530.538:7601 Fax: 530.538:7785 www.ButteCounty.net/dds Permit No: B17-1988 .Issued:'8/30/2617` APN:047-670=065 - Address:. 4025 AUGUSTA LN, CHICO , Owner: MURRAY 'STUART `A'REVOCABLE INTE , ' Permit Type:' SOLAR ROOF RES Description: Install 6 extra PV AC Modules to an existing ~ ; t a • t • ALL PLAN'REVISIONS MUST BE APPROVED'BY THE COUNTY, BEFORE PROCEEDING - Inspection Type IVR' INSP, DATE Setbacks` - . • e 131 Foundations/ Footings. 111 Pier/Column 'Footings 122 Eufer Ground ' 216 Masonry Grout 120 4; Setbacks - Do Not Pour Concrete Until Above are Signed Pre -Slab 124' Gas Test Underground/floor _7'404 - Gas, Piping'Underground/floor 403'... ` Underfloor Framing 149' Underfloor Ducts 319 • ' Shear Transfer '136 Under Floor Plumbing 412 Under Slab Plumbing 41 I 131 Blockin Unde inin 612 Tiedown/Soft•Set System < Do Not Install Floor Sheathing or.Slab Until'Above,Signed. ShearwallB.W.P.-Interior '134 Shearwall/B.W.P.-Exterior ,135 Roof Nail/Drag Trusses 129 Underground Water rlf Do Not Install Siding/Stucco o_' Roofing Until Above Signed Rough Framing. 153 . . :Rough Plumbing" '406. � Rough Mechanical 316 r Rough Electrical E ,,208: 4 -Way Rough Framing 128 - " Gas Piping House , 403- 03'`Gas GasTest House .' 404. - '4W Shower Shower Pan/Tub Test " -408 Do Not Insulate Until Above Signed Permit Final 802' Electrical Final _ 803 Mechanical Final 809 Plumbing Final 813 Fire Sprinkler Test,or Final 702 I. , 4; 'InspectionType IVR INSP , `DATE .T -Bar Ceiling145., r Stucco Lath' . 142 Swimming Pools Setbacks - , 131—, Pool Plumbing Test 504 Gas Test .404 k Pre-Gunite' 506 Pre -Deck F "' 505 Pool Fencing/Alanns/13atners 503 Pre -Plaster ` . 507 Manufactured Homes Setbacks 131 Blockin Unde inin 612 Tiedown/Soft•Set System < 611 Permanent Foundation System 613 Underground Electric 218' Sewer. 407 Underground Water 417 'Manometer Test -Continuity Test 602 Skirting/Steps/Landings 610 x ° Coach Info Manufactures Name: Date of Manufacture: "Model Name/Number: Serial Numbers: Len 'th x Width: lnsi•nia: Public Works Final" •538.7681 Fire De artment/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final f'y **: ROJECT. FINAL la Ib *Project Final is a Certificate of Occupancy for a denti O ly) PERMITS BECOME NULL AND VOID t.YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY R A.l YEAR RENEWAL 30 DAYS PRIOR 1-0 EXPIRATION Carbon monoxide alarms required by Sections. R3.15.1 and.R3.1.5.2 shall be installed in the - following locations: 1. Outside of 'aach separate dwelling unit sleeping area in the immediate vicinity of the bedroc m(si. 2. On every level of a dwelling unit including basements.. 8315.1.5 Multiple -purpose alarms: Carbon monoxide alarms combined with smoke alarms shall comply with Section R315, all applicable standards, and requirements for listing and approval by the Office of the State Fire Marshal, for smoke alarms. Butte County's Interpretation of 2013 CRC, Sections 3,14 & 315 for Smoke Alarms & Carbon Monoxide Alarms: Where alterations, repairs or additions exceeding $1,000 in valuation, existing dwellings shall be retrofitted with smoke alarms and those that have attachedag_rages or fuel -burning appliances shall have carbon monoxide alarms installed. Existing smoke alarms can be replaced with dual function alarms for Smoke and Carbon Monoxide and in most cases will comply with the aforementioned code requirement`s for Carbon Monoxide Alarms. DECLARATION OF INSTALLATION UNDER THE PENALTY OF PERJURY As Owner/Contractor, I/we affirm and declare under the penalty of perjury, under the laws of the State of -California, by our signatures below as Owner/Contractor, that I/we will comply prior to final inspection with Items A & B as specified herein: A. Both Owner/Contractor have read and clearly understand the aforementioned 2010 California Residential'Code (CRC) Carbon Monoxide Alarm requirements. B. Both Owner/Contractor are responsible for installing Carbon Monoxide Alarms prior to final inspection as per the aforementioned building code and. maintaining such installation. Smoke Alarms will also be installed prior to final inspection -as per the 2010 CRC. Smoke and Carbon Monoxide alarms are now installed in the following locations: Owner's name (print): ,l �T/ih�-� LIkAA" Owner's signature: X Date: 10 Contractor's name (print): 444 CSLB License: � Contractor's signature ,2���= Date: /ev Project Address: Z-/0 A 5 , A S� � � � Pefmit Page 2 of 2 ' Butte County Department of Development Services FORM NO PERMIT CENTER 7 County Center Drive, Oroville, CA 95965 - DBI -01 Main Phone (530) 538-7601 Fax (530) 538-7785 tY'h'.Y ht:TG:UUfr';.n�:.d<L;, Declaration ®f Installation for Smoke Alarms and Carbon Monoxide Alarms The newly adopted. 2013 California Residential Code requires the installation of Carbon Monoxide Detectors in dwelling units and in sleeping units within which fuel -burning appliances are installed and in dwelling units that have attached garages.. The policy for Carbon Monoxide Alarms in Butte County states: "Any permit obtained in which the value of work. exceeds $1000 associated with a Residential Group R Dwelling Unit or Sleeping Unit shall conform to the following 2013 California Residential Code requirements for Smoke and Carbon Monoxide Alarms (Section R314 & R315)." 2013 California Residential Code requirements for Carbon Monoxide Alarms: R315.1:,New construction: An approved carbon monoxide alarm shall be installed in dwelling units and in sleeping units within which fuel -burning appliances are installed and in dwelling units that have attached garages. 8315.1.2 Rower supply: For new construction required carbon monoxide alarms shall receive their primary power from the building wiring where such wiring is served from a commercial source and shall be equipped with a battery back-up. Alarm. wiring shall be, directly connected to the permanent building wiring without a disconnecting switch other than as required for over-, current protection. E.,cceptions. 1 1. [n dwelling units where there is no commercial power supply the carbon monoxide alarm maybe solely battery operated. 2. [n existing dwelling units a carbon monoxide alarm is permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. 8315.1.3 Interconnection. Where more than one carbon monoxide alarm is required to be installed within the dwelling unit or within a sleeping unit the alarm shall be interconnected in a manner that activation of one alarm shall activate all of the alarms in the individual unit. Exception: 1. Interconnection is not required in existing dwelling units where repairs do not result in the removal of wall and ceiling finishes, there is no access by means of attic basement or crawl space and no previous melhod for interconnection existed. 8315.2 Where required;;i;riyexisting dvvellings: Where a permit is required for alterations, repairs or,'additions exceed:i ig one thousand dollars ($1,000), existing dwellings or sleeping units that,ha've attached .gp' rages orfuel-burning"appliances shall be provided with a carbon monoxide alarm in accordance with Section 83'1:5.1. Carbon monoxide alarms shall only be required in the specific dwelling unit or sleeping,unit for which the permit was obtained. R315.2.6 Alarm requirements: No person shall install, market, distribute, offer for sale or sell any carbon monoxide device in the State of California unless the device and instructions have been approved and listed by the State Fire Marshal. Paee 1 of 2 PROJECT OWNER: MURRAY, STUART (6 PANEL ADDITION) 4025 AUGUSTA LANE CHICO, CA 95973 APN:047-670-065 PH#:530.520.9882 EMAIL:murraystu@sbcglobal.net CONTRACTOR: ALTERNATIVE ENERGY SYSTEMS INC. 13620 HIGHWAY 99• CHICO, CA 95973 CSLB: 853351 C-10, C-46 BUILDING JURISDICTION: BUTTE COUNTY DEPT. OF DEVELOPMENT SERVICES 7 COUNTY CENTER DRIVE OROVILLE, CA 95965 OFFICE#: (530) 538-7601 FAX#: (530) 538-2140 MON-FRI 8AM-3PM INSPECTION LINE: (530) 538-4365 REQUESTS PHONED IN BY 2PM WILL BE INSPECTED THE NEXT BUSINESS DAY cold X+i SCOPE: INSTALL PHOTOVOLTAIC SOLAR SYSTEM ON A TRUSS ROOF, MOUNTED IN ACCORDANCE WITH ALL APPLICABLE BUILDING CODES SPECIFICALLY REFERENCING THE 2016 CALIFORNIA ELECTRICAL CODE/ 2014 NEC USING THE FOLLOWING SPECIFIC EQUIPMENT: 1. MODULES: SUNPOWER (6) SPR -X21 -345 -D -AC - 2.07kW SYSTEM 109 SQFT COVERED :2. INVERTER(S): SUNPOWER: (6) MODULE'INTEGRATED 320W EACH ` SITE MAP VC4, PAGE # CONTENT PV -1.0 SCOPE PV -2.0 SITE PLAN PV -3.0 ARRAY LAYOUT PV -4.0 ELECTRICAL DIAGRAM PV -4.1 LABEL DIAGRAM PV -5.0 GENERAL NOTES ATTACHMENT MODULE SPECS Z o C -INVERTER SPECS ' RACKING SPECS. - WIRE CALCS o a 13620 HWY 99 g MURRAY STUART (6 PANEL ADDITION) o r Energy ForLlfe CHICO, CA 95973 Z o C Z 3 8 o PHONE#: (530) 345-6980 4025 AUGUSTA LANE®®� Vq p D CHICO, CA 95973 FAX#: (530) 892-2360 p o Alternative Energy Systems Inc.APN:047-670-065 PH#:530.520.9882 design@s6larenergyforlife.com t e. 44 S-1 (N) AC DISTRI,�BUTION,PANEL -■, - MODEM -AND ROUTER LOCATION, r (N) MONITORING' .. = (E) PGE METER& -` E MAIN SERVICE PANEL` `(E) COMPOSITION ROOF W/WOOD TRUSSES" + iE) RESIDENCE e t PHOTOVOLTAIC ARRAY -�- (P) PHOTOVOLTAIC ARRAY POOL Er. Fy' c, SITE PLAN 13620 HWY 99 S MURRAY, STUART (6 PANEL ADDITION) o v ' Energy ForufeCHICO, CA 95973 m <4 025 m 4025 AUGUSTA LANE G g PHONE#: (530) 345-6980 s N D o r CHICO CA 95973 Z p n m.. FAX#: (530) 892 2360 s z o v APN:047-670-065 PH#:530.520.9882 Alternative Energy Systems Inc. o design@solarenergyforlife.com PV ARRAY - _ AC DISCONNECT ' , MAIN ' F71[JEJEIN I ' - SUB PANEL �•` METER * .. + + + 1771 + -+ - - • .a,rs v y - , � - w.cs �rs •ars - t' — . - • _ AMPS •' �_' PHASE .. - - VOLTS , •• � y J. �z F } - i^•_• -. - .I � • � a ,--�' a - � � i = _gid .... ,. - ' � < .. . ' Vw� 1._ �. Y. _ - � WARNING UTILITY INTERACTIVE POWER FLOWING THROUGH THIS PANEL KW SOLAR GENERATOR, AC OPERATING VOLTAGE: WARNING VAC/ PHASE PHOTOVOLTAIC SYSTEM EQUIPPED DUAL POWER SUPPLY WITH RAPID SHUTDOWN PHOTOVOLTAIC SYSTEM • Per NEC 705.10, Point of Connection, w - * Located On Main Service Panel. AC PHOTOVOLTAIC • DISCONNECT .. , y ► - • - OPERATION •Disconne•on Per NEC 690. means at the single AC Disconnect or Main Breaker. ^ 'SOLAR .. - Solar breaker label @ any breaker passing,. } Bi -Directional Power • -' r ' - LABEL DIAGRAM o n MURRAY, STUART (6 PANEL ADDITION) 13620 H WY 99 • ,� o - Energy For Life CHICO, CA 95973. s Z 4025 AUGUSTA LANE N- • y g PHONE#: (530) 345-6980' 3 D p = n r CHICO, CA 95973 ®�� FAX#: (530) 892-2360 r !-' n p z o APN:047-670-065' PH#:530.520.9882 Alternative Energy Systems Inc. - design@sol arenergyforlife.com ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE 2014 NATIONAL ELECTRIC CODE (NEC), OR LOCAL MUNICIPAL CODE, AND FIRE DISTRICT REGULATIONS. 1. ALL EQUIPMENT SHALL BE LISTED AND LABELED PER RECOGNIZED ELECTRICAL TESTING LABORATORY AN INSTALLED PER THE LISTING REQUIREMENTS AND THE MANUFACTURER'S INSTRUCTIONS. 2. ALL INVERTERS SHALL BE IEEE 929 COMPLIANT AND SHALL BE INSPECTED BY LOCAL UTILITY BEFORE COMMISSIONING, TESTING, AND OPERATION OF THE SYSTEM. 3. ALL OUTDOOR EQUIPMENT SHALL BE MINIMUM NEMA 3R, INCLUDING OUTDOOR MOUNTED TRANSITION BOXES, COMBINER BOXES, AND SWITCHES. 4. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ART.250,690. 5. NEC. ART. 690.9(A). ALL CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE OVERCURRENT DEVICES LOCATED SO AS TO PROVIDE OVERCURRENT PROTECTION FROM ALL SOURCES. 6. NEC ART. 690.18. DUE TO THE FACT THAT PV MODULES ARE ENERGIZED WHENEVER THEY ARE EXPOSED TO LIGHT, PV CONTRACTOR SHALL DISABLE THE ARRAY DURING INSTALLATION AND SERVICE BY SHORT CIRCUITING, OPEN CIRCUITING, OR COVERING THE ARRAY WITH AN OPAQUE COVERING. 7. PHOTOVOLTAIC SYSTEM SHALL BACKFEED THE DISTRIBUTION SYSTEM ON SITE PER THE REQUIREMENTS OF NEC ART.690.64(B). ALL BACKFEED BREAKERS SHALL BE IDENTIFIED AS SUCH AND SHALL BE SECURED IN PLACE BY ADDITIONAL FASTENER PER THE REQUIREMENTS OF NEC 408.16(F) (408.36 IN 2014 NEC. 8. FALL ARREST PROTECTION PER OSHA REQUIREMENTS SHALL BE PROVIDED FOR ALL ROOF WORK. 9. ALL CONDUCTORS AND TERMINATIONS SHALL BE RATED FOR 75° C MINIMUM. 10. NEC ART. 690.14. -SEE SHEET RE -4.1 FOR LABEL DIAGRAM 11. NEC ART. 690.53. -SEE SHEET RE -4.1 FOR LABEL DIAGRAM 12. NEC ART. 690.17. EACH AC DISCONNECT SHALL ALSO BE LABELED WITH: "WARNING! -ELECTRICAL SHOCK HAZARD -DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIZE MAYBE ENERGIZED IN THE OPEN POSITION". 13. GROUNDING OF ALL DWELLINS SHALL BE CONFIRMED. 14. CONTRACTOR TO PROVIDE GROUND FAULT PROTECTION FOR ROOF MOUNTED PHOTOVOLTAIC ARRAYS LOCATED ON DWELLINGS PER 2014 NEC ART.690.17. 15. WHERE MORE THAN ONE NOMINAL VOLTAGE SYSTEM EXIST, THE DIFFERENT SYSTEMS SHALL BE IDENTIFIED BY PHASE AND SYSTEM PER 2014 NEC ART.210.41) 16. PROVIDE AN ACCESSIBLE DISCONNECT DEVICE THAT IS LOCKABLE IN OPEN POSITION AND IS LOCATED WITHIN 10'-0" OF THE METER PER LOCAL ELECTRICAL UTILITY REGULATIONS. 17. PHOTOVOLTAIC SOURCE CURRENTS MUST BERATED AT BOTH 125% OF THE PARALLEL MODULE AND AT A CONTINUOUS LOAD OF ANOTHER 125% FOR A TOTAL OF 156% OF THE LOAD. 18. PROVIDE PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECT MEANS IF THEY ARE NOT IN THE SAME LOCATION PER 2014 NEC ART.690.56. 19. INSTALLATION OF PV PANEL ARRAYS SHOULD RESIST SLIDING AND POP-UP RESULTING FROM SEISMIC EVENTS AND SHOULD COMPLY WITH CBC SECTION 1613A AND ASCE STANDARD 7-05, CHAPTER 13. 20. PV SYSTEM INSTALLER WILL BE RESPONSIBLE FOR FURNISHING AND INSTALLATION OF ALL RELATED EQUIPMENT, CABLES, ADDITIONAL CONDUITS, BOXES WIREWAYS AND OTHER ACCESSORIES NECESSARY FOR COMPLETE AND OPERATIONAL PHOTOVOLTAIC SYSTEMS. 21. PV SYSTEM CONTRACTOR SHALL COORDINATE ALL THE WORK WITH THE ENGINEER, THE CONSTRUCTION MANAGER AND ALL OTHER CONTRACTORS TO ENSURE THAT PV SYSTEM IS INSTALLED AS SPECIFIED IN THESE DRAWINGS. 22. DRAWING IN GENERAL OR DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF THE EQUIPMENT AND WORK INCLUDED. THE INTENTION OF THE DRAWING IS TO INDICATE SIZE, CAPACITY, APPROXIMATE LOCATION AND GENERAL RELATIONSHIP, BUT NOT EXACT DETAIL OR PHYSICAL PLACEMENT. 23. FIELD VERIFIES EXACT AIC RATING REQUIRED OF THE MAIN SWITCHBOARD FROM LOCAL UTILITY. 24. A PV SYSTEM WITH MULTIPLE INVERTERS, WHERE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, WILL HAVE A DIRECTORY CREATED FOR EACH LOCATION. AS PER 2014 NEC 690.5(H) AND IN ACCORDANCE WITH 2014 NEC 705.10. 25. A NON FOLDING LADDER WILL BE IN PLACE AND SECURED TO THE ROOF TO PROVIDE ACCESS FOR ALL INSPECTIONS. ALL BOXES WILL BE OPENED UPON REQUEST. 26. SMOKE AND CARBON MONOXIDE ALARMS WILL BE INSTALLED IN ACCORDANCE WITH CRC R314 R315 G) _ „ °� a MURRAY, STUART (6 PANEL ADDITION) 13620 HWY 99 p o - Ener For Life 9y CHICO, CA 95973 m D o 0 4025 AUGUSTA LANE SPHONE#: (530) 345 6980 Z ° a C p a ° " CHICO CA 95973 ®�� FAX#: (530) 892-2360 Z APN:047-670-065 PH#:530.520.9882 Alternative Energy Systems Inc. design@solarenergyforlife.com J6ne 22, 2017 To Whom it May Concern, In order to meet future advanced grid requirements, SunPower® is transitioning from Type C ACmodulesto Type D AC modules. The purpose of this letter,is to demonstrate the mechanical and electrical`equivalency of Type C AC modules l and Type D AC modules. Type D AC modules are drop-in replacements for Type C AC modules and are available at the same DC and AC power levels. Type D AC modules have the same form, fit, and function as Type C AC modules. The AC electrical output specifications of Type C AC modules and Type DAC modules are equivalent, ensuring interchangeability for AC conductors, overcurrent protection. devices, and grounding. SunPower Type D AC modules are certified per LIC1741 SA to the,following SRDs: IEEE 1547, IEEE 1547a, and CPUC Rule 21 Phase 1. These additional certifications and functionality enable Type D AC modules.to meet California CPUC Rule 21 Phase 1 smart inverter requirements. -The following table lists the Type C AC module models and their respective Type D _ equivalents, as of the date of this letter: Where Type D AC modules are substituted in the field for. Type C AC modules; no changes to the physical layout,,structu'ral loading, electrical.design; or interconnection are required. Should you have any_questions or concerns, please contact SunPower Technical Support at 1-800-786-7693. Best Regards, i ! Matt Mayberry ' Director, Residential Product Management I .- E19 -320 -C -AC E19 -320 -D -AC E20 -327 -C -AC E20 -327 -D --AC X21-3357BLK-C-AC X21-335-BLK=D-AC ' X21 -335 -C -AC- X21 -335 -D -AC ` X21 -345 -C -AC • ,._ - X21 -345 -D -AC X22 -360 -C -AC X22 -360 -D -AC Where Type D AC modules are substituted in the field for. Type C AC modules; no changes to the physical layout,,structu'ral loading, electrical.design; or interconnection are required. Should you have any_questions or concerns, please contact SunPower Technical Support at 1-800-786-7693. Best Regards, i ! Matt Mayberry ' Director, Residential Product Management I Design -Driven Advantages #1 module aesthetics and efficiency' Unmatched module reliability2 No electrolytic capacitors 25 -year Combined Power and Product. Warranty California Rule 21 Phase 1 compliant Maximize Value for Roof , Size system for roof, not string inverter Optimize performance of each module Expand Deployment Options. Complex roofs and partial shading Small systems System expandability Simplify & Speed Installation Factory -integrated microinverter Robust, double -locking AC connectors Design flexibility offsite and onsite No DC string sizing process Fewer installation steps than competing, systems Intuitfve commissioning Component of Complete System Built for use with SunPower' InvisiMountlm and the SunPower Monitoring System (PVS5x) Superior system reliability and aesthetics It E Optimize System and Installation Efficiency X SERIES Sun?owerryAC modules, which include a factory -integrated SunPower microinverter, provide a revolutionary combination of high efficiency, high reliability, and module -level DC -to -AC power conversion. Designed specifically for use with SunPower InvisirMountT'" and the SunPower Monitoring System, SunPower AC modules enable rapid installation, best - in -class system aesthetics, and intuitive visibility into system performance. All this comes with the best Combined Power and Product Warranty in the industry. Grid Support Utility -Interactive Smart Inverter SunPower's new Type D AC module is UL tested and certified to UL 1741, SA and provides advanced smart inverter functions. SunPower Type D AC modules are fully compliant with the California Rule 21 Phase 1 requirements, and the Rule 21 grid profile is easily set during commissioning with SunPower PVS5x monitoi ing hardware. sunpower.com 'Highest of over 3,200 silicon solar panels. Photon Module Survey, Feb. 2014 .`.1 rank in "PV Module Durability Initiative Public Repor-" Fraunhofer CSE, Feb 2013. Five out of the top eight largest manufacturers were tested. Campeau, Z. ei al. "SunPower Module Degradation Rate," SunPower white paper, Feb 2013. See www.sunpower.com/facts for details. '•Factory set to 1547a-2014 default settings. CA Rule 21 default settings profile set during commissioning. See the Equinox Installation Guide ;518:'Oi for more information. 'Standard Test Conditions (1000 w/m2 irradiance, AM 1.5, 25" C). NREL calibration standard: SOMS current, LACCS FF and voltage. All DC voltage is fully contained within Elie module. 5Based on average of pleasured power values during production. . Seewww.sunpower.com/facts for more reference information. For more details, see extended datasheet: wwwsunpower.com/daiasheets. Warranties 25 -year limited power warranty 25 -year limited product warranty UL listed to UL 1741 SA SRDs: IEEE 1547-2003, IEEE 1547a-2014, CA Rule 21 Phase 1 PV Rapid Shutdown Equipment Equipment Grounding UL 6703, UL 9703 Connectors and cables (load break disconnection) UL 1741 AC Module (Type 2 fire rating) Certifications Enables installation in accordance with: NEC 690.6 NEC 690.12 Rapid Shutdown (inside and outside the array) NEC 690.15 AC Connectors, 690.33(,) - (E)(1) FCC and ICES -003 Class B When used with InvisiMount racking (UL 2703): Integrated grounding and bonding Class A fire rated PID Test Potential -induced degradation free 1558 mm ~- [6131n) Please read the safety and installation instructions for details '30 mm' [72 in] U` Xe cmnasroerennr ® wreL.cmE N RAM aenoowa LISTED soe�o Module Rn Perillrmo— Type 2• 518982 RevB MO. SPR -X21 -345 -D -AC ' 9R -X21 -345 -D -AC ,Nominal Power" (Pnom) 345 W 335W IEEE 1547a-20143. CA Rule 21 SRD Profile 21.5% 21.0% (default settings) min. % nom. / max. Shade Tolerance • Three bypass diodes Integrated module -level maximum power point tracking in. / nom. / max. Frequency (Hz) 59.5 / 60.07 60.5 , 58.5 / 60.0 / 60.5 Power Factor 0.99 / 1.00 / 1.00 0.85 lead. / 1.00 / 0.85 lag. Reactive Power ±169 Var Volt-VAr Voltage @240 V 211.2 / 240 / 264 V @208 V 183 / 208 / 228.8 V Max. Curren'i @240 V 1.33 A @208 V 1.54 A DC/AC CEC Conversion Efficiency @240 V 96.0% @208 V 95.5% Max. Units Per 20'A Branch Circuit @240 V 12 (sinle phase) @208 V 10 (two pole) avye Power 320 W, 320 VA No active phase balancing for 3 phase installations 'Highest of over 3,200 silicon solar panels. Photon Module Survey, Feb. 2014 .`.1 rank in "PV Module Durability Initiative Public Repor-" Fraunhofer CSE, Feb 2013. Five out of the top eight largest manufacturers were tested. Campeau, Z. ei al. "SunPower Module Degradation Rate," SunPower white paper, Feb 2013. See www.sunpower.com/facts for details. '•Factory set to 1547a-2014 default settings. CA Rule 21 default settings profile set during commissioning. See the Equinox Installation Guide ;518:'Oi for more information. 'Standard Test Conditions (1000 w/m2 irradiance, AM 1.5, 25" C). NREL calibration standard: SOMS current, LACCS FF and voltage. All DC voltage is fully contained within Elie module. 5Based on average of pleasured power values during production. . Seewww.sunpower.com/facts for more reference information. For more details, see extended datasheet: wwwsunpower.com/daiasheets. Warranties 25 -year limited power warranty 25 -year limited product warranty UL listed to UL 1741 SA SRDs: IEEE 1547-2003, IEEE 1547a-2014, CA Rule 21 Phase 1 PV Rapid Shutdown Equipment Equipment Grounding UL 6703, UL 9703 Connectors and cables (load break disconnection) UL 1741 AC Module (Type 2 fire rating) Certifications Enables installation in accordance with: NEC 690.6 NEC 690.12 Rapid Shutdown (inside and outside the array) NEC 690.15 AC Connectors, 690.33(,) - (E)(1) FCC and ICES -003 Class B When used with InvisiMount racking (UL 2703): Integrated grounding and bonding Class A fire rated PID Test Potential -induced degradation free 1558 mm ~- [6131n) Please read the safety and installation instructions for details '30 mm' [72 in] U` Xe cmnasroerennr ® wreL.cmE N RAM aenoowa LISTED soe�o Module Rn Perillrmo— Type 2• 518982 RevB Operating Temp. SPR -X21 -345 -D -AC ' 9R -X21 -345 -D -AC ,Nominal Power" (Pnom) 345 W 335W Power Tolerance =5/-0% -+5/-0% Avg. Panel Efficiency-- 21.5% 21.0% Temp. Coef. (Power) -0.29%/1C ' Shade Tolerance • Three bypass diodes Integrated module -level maximum power point tracking 'Highest of over 3,200 silicon solar panels. Photon Module Survey, Feb. 2014 .`.1 rank in "PV Module Durability Initiative Public Repor-" Fraunhofer CSE, Feb 2013. Five out of the top eight largest manufacturers were tested. Campeau, Z. ei al. "SunPower Module Degradation Rate," SunPower white paper, Feb 2013. See www.sunpower.com/facts for details. '•Factory set to 1547a-2014 default settings. CA Rule 21 default settings profile set during commissioning. See the Equinox Installation Guide ;518:'Oi for more information. 'Standard Test Conditions (1000 w/m2 irradiance, AM 1.5, 25" C). NREL calibration standard: SOMS current, LACCS FF and voltage. All DC voltage is fully contained within Elie module. 5Based on average of pleasured power values during production. . Seewww.sunpower.com/facts for more reference information. For more details, see extended datasheet: wwwsunpower.com/daiasheets. Warranties 25 -year limited power warranty 25 -year limited product warranty UL listed to UL 1741 SA SRDs: IEEE 1547-2003, IEEE 1547a-2014, CA Rule 21 Phase 1 PV Rapid Shutdown Equipment Equipment Grounding UL 6703, UL 9703 Connectors and cables (load break disconnection) UL 1741 AC Module (Type 2 fire rating) Certifications Enables installation in accordance with: NEC 690.6 NEC 690.12 Rapid Shutdown (inside and outside the array) NEC 690.15 AC Connectors, 690.33(,) - (E)(1) FCC and ICES -003 Class B When used with InvisiMount racking (UL 2703): Integrated grounding and bonding Class A fire rated PID Test Potential -induced degradation free 1558 mm ~- [6131n) Please read the safety and installation instructions for details '30 mm' [72 in] U` Xe cmnasroerennr ® wreL.cmE N RAM aenoowa LISTED soe�o Module Rn Perillrmo— Type 2• 518982 RevB Operating Temp. -40° F to +1851 F (-401 C to +851 Q Max. Ambient Temp. 1221 F (501 Q INlax. Load Wind: 62 psf, 3000 Pa, 305 kg/M2 front & back Snow: 125 psf, 6000 Pa, 611 kg/M2 front Impact Resistance 1 inch (25 mm) diameter hail at 52 mph (23 m/s) 'Highest of over 3,200 silicon solar panels. Photon Module Survey, Feb. 2014 .`.1 rank in "PV Module Durability Initiative Public Repor-" Fraunhofer CSE, Feb 2013. Five out of the top eight largest manufacturers were tested. Campeau, Z. ei al. "SunPower Module Degradation Rate," SunPower white paper, Feb 2013. See www.sunpower.com/facts for details. '•Factory set to 1547a-2014 default settings. CA Rule 21 default settings profile set during commissioning. See the Equinox Installation Guide ;518:'Oi for more information. 'Standard Test Conditions (1000 w/m2 irradiance, AM 1.5, 25" C). NREL calibration standard: SOMS current, LACCS FF and voltage. All DC voltage is fully contained within Elie module. 5Based on average of pleasured power values during production. . Seewww.sunpower.com/facts for more reference information. For more details, see extended datasheet: wwwsunpower.com/daiasheets. Warranties 25 -year limited power warranty 25 -year limited product warranty UL listed to UL 1741 SA SRDs: IEEE 1547-2003, IEEE 1547a-2014, CA Rule 21 Phase 1 PV Rapid Shutdown Equipment Equipment Grounding UL 6703, UL 9703 Connectors and cables (load break disconnection) UL 1741 AC Module (Type 2 fire rating) Certifications Enables installation in accordance with: NEC 690.6 NEC 690.12 Rapid Shutdown (inside and outside the array) NEC 690.15 AC Connectors, 690.33(,) - (E)(1) FCC and ICES -003 Class B When used with InvisiMount racking (UL 2703): Integrated grounding and bonding Class A fire rated PID Test Potential -induced degradation free 1558 mm ~- [6131n) Please read the safety and installation instructions for details '30 mm' [72 in] U` Xe cmnasroerennr ® wreL.cmE N RAM aenoowa LISTED soe�o Module Rn Perillrmo— Type 2• 518982 RevB Solar Cells 96 Monocrystalline Maxeon Gen III Glass Frontrefective High-transmiss"on tempered glass with anti- coating Environmental Rating Outdoor rated Frame Class 1 black anodized (highest AAMA rating) Weight 45.5 lbs (20.6 kg) Recommended Max. (Module Spacing 1.3 in. (33 mm) 'Highest of over 3,200 silicon solar panels. Photon Module Survey, Feb. 2014 .`.1 rank in "PV Module Durability Initiative Public Repor-" Fraunhofer CSE, Feb 2013. Five out of the top eight largest manufacturers were tested. Campeau, Z. ei al. "SunPower Module Degradation Rate," SunPower white paper, Feb 2013. See www.sunpower.com/facts for details. '•Factory set to 1547a-2014 default settings. CA Rule 21 default settings profile set during commissioning. See the Equinox Installation Guide ;518:'Oi for more information. 'Standard Test Conditions (1000 w/m2 irradiance, AM 1.5, 25" C). NREL calibration standard: SOMS current, LACCS FF and voltage. All DC voltage is fully contained within Elie module. 5Based on average of pleasured power values during production. . Seewww.sunpower.com/facts for more reference information. For more details, see extended datasheet: wwwsunpower.com/daiasheets. Warranties 25 -year limited power warranty 25 -year limited product warranty UL listed to UL 1741 SA SRDs: IEEE 1547-2003, IEEE 1547a-2014, CA Rule 21 Phase 1 PV Rapid Shutdown Equipment Equipment Grounding UL 6703, UL 9703 Connectors and cables (load break disconnection) UL 1741 AC Module (Type 2 fire rating) Certifications Enables installation in accordance with: NEC 690.6 NEC 690.12 Rapid Shutdown (inside and outside the array) NEC 690.15 AC Connectors, 690.33(,) - (E)(1) FCC and ICES -003 Class B When used with InvisiMount racking (UL 2703): Integrated grounding and bonding Class A fire rated PID Test Potential -induced degradation free 1558 mm ~- [6131n) Please read the safety and installation instructions for details '30 mm' [72 in] U` Xe cmnasroerennr ® wreL.cmE N RAM aenoowa LISTED soe�o Module Rn Perillrmo— Type 2• 518982 RevB Modu!e* / Mid Clamp and Rail Module* / End Clamp and Rail Mid Clamo crid Clamp Rail Rail Splice• Cap Composition Shingle P,after Atiachmenc Application Composition Shingle Roof Decking Attachment Curved and Pat Tile Roof Attachment Universal Interface for Other Roof Attachments temperature - -40° C to 90° C (-40° F to 194° F) Max. Load 2400 Pa uplift 5400 Pa downforce Component Material Weight Mid Clamp Black oxide stainless steel AISI 304 63 g (2.2 oz) End Clamp Black anodized aluminum alloy 6063-T6 110 g (3.33 oz) Rail Black anodized aluminum alloy 6005-T6 330 g/m (9 oz/ft) Rail Splice Aluminum alloy 600S -T5 330;/m (9 oz/ft) Ground Lug Assembly(A2-70 304'stainless bolt, tin-plated copper lug) i 06.5 g/m (3.75 oz) End Cap Black acetal (POM) copolymer 10.4 g (0.37 oz) Composition Shingle P,after Atiachmenc Application Composition Shingle Roof Decking Attachment Curved and Pat Tile Roof Attachment Universal Interface for Other Roof Attachments temperature - -40° C to 90° C (-40° F to 194° F) Max. Load 2400 Pa uplift 5400 Pa downforce ••• • Refer to roof attachment hardware manufacturer's documentation Module trame that is compatible with the Invlsit fount system required for hardware Interoperability. , i S2015$UnPowerCorporation. A!IRights Reserved. SUNPOYJER, the SUIPOWERlogo, and 1M/ISIfdOU�,% are'tradem'arksorregistered trademarks of SunPower Corporation All other trademarks are the property of ;heir respective owners. Specifications included in this datasheet are subject to change without notice. . sunpower,com Document #S09506 Rev 8 25 -year product warranty 5-yearfinish warrant/ UL 2703 Listed Certifications Class A fire rating when distance between roof surface and bottom of SunP ower module frame is <- 3.5" ••• • Refer to roof attachment hardware manufacturer's documentation Module trame that is compatible with the Invlsit fount system required for hardware Interoperability. , i S2015$UnPowerCorporation. A!IRights Reserved. SUNPOYJER, the SUIPOWERlogo, and 1M/ISIfdOU�,% are'tradem'arksorregistered trademarks of SunPower Corporation All other trademarks are the property of ;heir respective owners. Specifications included in this datasheet are subject to change without notice. . sunpower,com Document #S09506 Rev 8 INVISIMOUNT .RACKINGrtDETAIL SOLAR MODULE 4 ' - END CLAMP , ' r MID CLAMP - INV ISIMOUNT- RAIL EACH MID CLAMP _ GROUNDS THE ' ` i,. - . MODULE TO THERAIL *INVISIMOUNT RAIL L-FOOT GreenFasten" GF1 - Product Guide Ir It 16�, - l 11- 1 2. Consult an engineer or go to www.ecofastensolar.com for engineering data. Installation Instructions with Compression Bracket A4 + .7 •r� % °c.: }tom i y it � fv r �++ S4! ��'Ti•`_ ft rr s� r.'aH �#1 i+; .I� , y..���. 1`�„�4 .r'r� tjl` �� sr! r r�r .� `•s..r+ �-:r >r' of4 Cr � +~Y,,% � � L� ��• f �`�r �fi KT� ha.� 'r. Y f i T .. ,.,tiaY�y � •Cfj - z 3 4a 4b 4c 1. Locate the rafters and snap horizontal and vertical lines to mark the installation position for each GreenFasten flashing. 2. Drill a pilot hole (1/4"diameter) for the lag bolt. Backfill with sealant. EcoFasten Solar recommends an EPDM mastic. 3. Insert the flashing so the top part is under the next row of shingles and pushed far enough up slope to prevent water infiltration through vertical joint in shingles. The leading edge of flashing must butt against upper row of nails to prevent turning when tourqued. See page 2.2 for vertical adjustment when leading edge of flashing hits nails in upper shingle courses. 4. Line up pilot hole with GreenFasten flashing hole. 4a Insert the lag bolt through the EPDM washer, the top compression component bracket (L- 102-3, L-102-6*, SCL-101-3*, Z-101*, Conduit Mount Bracket*) and the gasketed hole in the flashing and into the rafter. 4b Insert the lag bolt through the EPDM washer, the Comp Mount Slide compression bracket and the gasketed hole in the flashing and into the rafter. 4c Insert the lag bolt through the SS washer, the third -party bracket, the EPDM bonded washer, the CP -SQ -Slotted compression bracket and the gasketed hole in the flashing and into the rafter. 5. Torque:The range is between 100-140 torque inch -pounds depending on the type of wood and time of year.The visual indicator for proper torque is when the EPDM on the underside of the bonded washer begins to push out the sides as the washer compresses. If using an impact wrench to install the fasteners be careful not to over torque the fastener. You may need to stop and use a ratchet to finish the install. *not pictured. 877-859-3947 EcoFasten Sola&All content protected under copyright. All rights reserved. 7/24/2014 EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 B2 8,153,700 B2 8.181,398 132 8.166,713 132 8,146.299 132 8.209,914 B2 8.245.454 B2 8.272.174 B2 8,225.557 132 2.1 ORR 2. Consult an engineer or go to www.ecofastensolar.com for engineering data. Installation Instructions with Compression Bracket A4 + .7 •r� % °c.: }tom i y it � fv r �++ S4! ��'Ti•`_ ft rr s� r.'aH �#1 i+; .I� , y..���. 1`�„�4 .r'r� tjl` �� sr! r r�r .� `•s..r+ �-:r >r' of4 Cr � +~Y,,% � � L� ��• f �`�r �fi KT� ha.� 'r. Y f i T .. ,.,tiaY�y � •Cfj - z 3 4a 4b 4c 1. Locate the rafters and snap horizontal and vertical lines to mark the installation position for each GreenFasten flashing. 2. Drill a pilot hole (1/4"diameter) for the lag bolt. Backfill with sealant. EcoFasten Solar recommends an EPDM mastic. 3. Insert the flashing so the top part is under the next row of shingles and pushed far enough up slope to prevent water infiltration through vertical joint in shingles. The leading edge of flashing must butt against upper row of nails to prevent turning when tourqued. See page 2.2 for vertical adjustment when leading edge of flashing hits nails in upper shingle courses. 4. Line up pilot hole with GreenFasten flashing hole. 4a Insert the lag bolt through the EPDM washer, the top compression component bracket (L- 102-3, L-102-6*, SCL-101-3*, Z-101*, Conduit Mount Bracket*) and the gasketed hole in the flashing and into the rafter. 4b Insert the lag bolt through the EPDM washer, the Comp Mount Slide compression bracket and the gasketed hole in the flashing and into the rafter. 4c Insert the lag bolt through the SS washer, the third -party bracket, the EPDM bonded washer, the CP -SQ -Slotted compression bracket and the gasketed hole in the flashing and into the rafter. 5. Torque:The range is between 100-140 torque inch -pounds depending on the type of wood and time of year.The visual indicator for proper torque is when the EPDM on the underside of the bonded washer begins to push out the sides as the washer compresses. If using an impact wrench to install the fasteners be careful not to over torque the fastener. You may need to stop and use a ratchet to finish the install. *not pictured. 877-859-3947 EcoFasten Sola&All content protected under copyright. All rights reserved. 7/24/2014 EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 B2 8,153,700 B2 8.181,398 132 8.166,713 132 8,146.299 132 8.209,914 B2 8.245.454 B2 8.272.174 B2 8,225.557 132 2.1 GreenFasten"GF1 - Product Guide Installation Instructions * Use for vertical adjustment when leading edge of flashing hits nails in upper shingle courses . Slide flashing up under shingles until leading edge engages nails. Measure remaining distance to adjust shingle 3. Reinstall flashing with notched area upslope. shingle 2. Remove flashing and cut "V" notch at marks where nail shafts engaged leading edge of flashing the distance desired in Step 1. Notch depth not to exceed 2" length by 1 /2" width. .14 Placement of "V" notch - t 4. Position notched leading edge underneath nail heads as shown. Nails beneath shingle 3. sI AM 9 Ar I P " i ;)- l 877-859-3947 EcoFasten Solar" All content protected under copyright. All rights reserved. 7/24/2014 - - �J EcoFasten Solar products are protected by the following U.S. Patents: 8.151.522 B2 8,153,700 B2 8.181,398 B2 8.166.713 B2 8.146.299 B2 8,209,914 B2 8.245.454 B2 8.272,174 B2 8.225.557 B2 2.2 'fa ,Ylj 1iY'a �1 r P brK y� •e3�t, ilex l}°' �,�a h 1Jr h'r i 1 ;.F�'f3'�5,{ ?.,1.� <� tl r�.3J.,y}`�1A1 } �i C.�a �� G� �► °�.�_ a r��l�"i.��'S 3A ��. � ��.J e9 r y�r}.'� s,..� i §y c'i�•k� '"V��f �,.ri �.3���1!'� rha �6 J{� lrr! r �.i -0(L 1� 7 .y ?'�a .,y. Yitl �J L. W��i %j KR A �. LT 'ft 7 • f is HA 1�Le �': ti• �.. .j �Y-•2.'+'A I a' x'kl d Y ��+- 1Y ri: �' yy 2 ' ryyr,\ {:'•�? f.; } � 4� � , rr ail ..y. i�r�'';.t f Z r ) ?� � ► li'1 �r.h. .5r r r .�''b3 +L, .,� , ��OIJ�C `y f/� �j•ry +d. � It �( yI 'c*'`�` ti-si�yl+�"f f 'r ti. � t'y.. � �e�i^C„P.«�•�r;a sLy�7'e`,�' �,y,�k,,, „C i� c�..�v !� � w¢;i {'�?i..r.�'2,�✓: j � ��+'�� diy Y l � �� M` `'�el (4`� �'S �yy / .'il. F�,'.e� �V Slh'�N i'' F.i� '� �'i?.'ff✓ ? �� j;/����hj C �...... „r ' �Y S,Fi •�':lt.,•r <"t^y> � F Ylt ���qy .f 3 �Ji" 4 1: ./ T F -� R �� s ... •-r�� 4' .�j � ��� Gr,*rs F vF$�•r :af',`�1ry':x S" i>t ✓ yF. J ,. �ldxt�sf�>".�;.y�.•yy ..,� ii,,r�r,.r �. t�� P " i ;)- l 877-859-3947 EcoFasten Solar" All content protected under copyright. All rights reserved. 7/24/2014 - - �J EcoFasten Solar products are protected by the following U.S. Patents: 8.151.522 B2 8,153,700 B2 8.181,398 B2 8.166.713 B2 8.146.299 B2 8,209,914 B2 8.245.454 B2 8.272,174 B2 8.225.557 B2 2.2 GreenFasten" GF1 — Product Guide Cut Sheets: GF1 Al \ ! ` R G ,ta 'SECTION A—A t►E«�i 1� 877-859-3947 EcoFasten Solar*'All content protected under copyright. All rights reserved. 7/24/20143.1 �' EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 B2 8,153,700 B2 8,181,398 B2 8,166.713 B2 8.146.299 62 8,209.914 B2 8,245.454 62 8.272.174 B2 8.225.557 B2 Green_Fasten-GF1 -Product Guide Cut Sheets: GF1- 812 1/32-4 i y C\1 16 5/64 M . 16 DETAIL A 4^ SCALE: 2:1 P ���y' }{ori S•! r � C -N .. .• f � , - • . Finish Options tl �� T \�tii r'- BILK Matte Black u ' MLL = Mill Finish 4' s � • t 'r V • 1 " 877-859-3947 EcoFasten Solar' All content protected under copyright. All rights reserved. 7/24/2014 3.2 �"���" EcoFasten Solar products are protected by the following U.S. Patents: 8.151.522 B2 8.153.700 B2 8,181,398 B2 8.166,713 B2 8.146.299 82 8,209.914 B2 8,245,454 B2 8,272,174 B2 8,225.557 B2 + GreenFasten" GF1 - Product Guide 4Cut Sheets: Bracket Options - CP-SQ=Slotted ' 1 ' sl 11 I�• . • 1 . , `• •. ' • ' ._ . - ' .. �. � ,itis.] � ... .. /. �h ' t' ^�+ "- ' 'i. -Fty- ''. � � �. • .. .. . - .� r r 1.50 — .06 2.00 , .e } ♦ ' . - - Wi 01 1.00 _ 00.38=,00 S 0.50 c 0.0.88±.0 l' X 82° G' 2.00 — DjI Vm 877'8 59-3947 EcoFasten Solar®All content protected under copyright. All rights reserved. 7/24/2014 3.3 EcoFasten Solar products are protected by the following U.S. Patents: 8,151.522 B2 8,153.700 B2 8.181.398 B2 8.166,713 132 8,146.299 B2 8,209.914 B2 8,245.%754 132 8.272.174 132 8,225.557 132 4 !1 ! , �. � ,itis.] � ... .. /. �h ' t' ^�+ "- ' 'i. -Fty- ''. � � �. • .. .. . - .� r r 1.50 — .06 2.00 , .e } ♦ ' . - - Wi 01 1.00 _ 00.38=,00 S 0.50 c 0.0.88±.0 l' X 82° G' 2.00 — DjI Vm 877'8 59-3947 EcoFasten Solar®All content protected under copyright. All rights reserved. 7/24/2014 3.3 EcoFasten Solar products are protected by the following U.S. Patents: 8,151.522 B2 8,153.700 B2 8.181.398 B2 8.166,713 132 8,146.299 B2 8,209.914 B2 8,245.%754 132 8.272.174 132 8,225.557 132 jjyyyggqy{11�1r'''1;`,'i' , "}yA, ''i.f GreenFasten" GIF 1 - Product Guide • - -Cut Sheets: Bracket Options - SCL-101-3" ,3/8" - j`.46 SERRATIONS .a R1 16" 3/4.. 1/16 R.005 q R.010 ° s 60.00 y 0 3/8: +:002 -1 /8„ � < - {-:; U 7/8" X 829DETAIL A . SCALE 3:1 J3j � t ot 877-859-3947 EcoFasten Solar" All content'protected under copyright. All rights reserved. 7/24/2014 3.$ 1 / EcoFasten Solar products are protected by the following U.S. Patents: 8.151.522 132 8.153.700 82 8.181,398 B2 8.166.713 B2 8.146.299 B2 8.209.914 B2 8,245,454 132 8.272.174 132 8.225.557 B2 , GreenFasten'" GF1 Product Guide Cut Sheets: Bracket Options - L-102-3" �i ." ,la Its f • - - r - • ".. r 't r. , - v r L -.F ., n — r -.l lei a 46 SERRATIONS LO \ , N 1 7�8': _ ' l 5/16" R.1 / 16.. 00,, r 3/4 /4 , R.005 77 R.0 10 t'2 X,R.oI 60.000 D ` „+.gob V,4 f ,�3/8 -.002 1 /8ff. 4j .875 +-.010 X 820 DETAIL A r , ,SCALE 3.1 ;. t { 1% 877-859-3947 EcoFasten Solar®AII content protected under copyright. All rights reserved. 7/24/2014 ' i^ ` EcoFasten Solar products are protected bG the following U.S. Patents: 8.151.522 B2 8,153,700 62 8.181.398 82 8.166,713 62 8.146.299'B2 8.209.914 B2 8.245.454 132 8.272.174 B2 8,225.557 132 3.6