Loading...
HomeMy WebLinkAboutB17-2031 047-300-112DEVELOPMENT SERVICES BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES INSPECTION CARD MUST BE ON JOB SITE 24 Hour Inspection Line (IVR) : 530.538.4365 (Cut off time for inspections is 3pm) Development Services'cannot guarantee inspections on the date requested . Office: 530.538.7601 Fax: 530.538.7785 www.ButteCountv.net/dds Permit No: B 17-2031 Issued: 9/5./2017 APN: 047-300-112 Address: 4237 KATHY LN, CHICO Owner: Keith Hard Permit Type` SOLAR ROOF -RES Description: Install 6.9kw roof mount to existing meter AREA 4 Flood Zone: None SRA Area: No W.TBACKS for Zpninv. AG_ SRA_ PW Front: Centerline of Road: Rear: SRA: Street: AG: Interior Total Setback from Centerline of Road: ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING Inspection Type IVR INSP DATE Setbacks 131 Foundations / Footings 111 Pier/Column Footings 122 Eufer Ground 216 Masonry Grout 120 Setbacks 131 Do Not Pour Concrete Until Above are Signed Pre -Slab 124 Gas Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing 149 Underfloor Ducts 319 Shear Transfer 136 Under Floor Plumbing 412 Under Slab Plumbing 411 Blockin /Unde inin 612 Tiedown/Soft Set System 611 Do Not Install Floor Sheathing or Slab Until Above Signed Shearwall/B.W.P.-Interior 134 ShearwalUB.W.P.-Exterior 135 Roof Nail/Drag Trusses 129 417 Manometer Test Do Not Install Siding/Stucco or Roofing Until Above Signed Rough Framing 153 Rough Plumbing 406 Rough Mechanical 316 Rough Electrical 208 4 -Way Rough Framing 128 Gas Piping House 403 Gas Test House 404 Shower Pan/Tub Test 408 Do Not Insulate Until Above Signed Permit Final 802 Electrical Final 803 Mechanical Final 809 Plumbing Final 813 Fire S rinkler Test or Final 702 Swimmin2 Pools Inspection Type IVR INSP DATE T -Bar Ceiling 145 Stucco Lath 142 . Swimmin2 Pools Setbacks 131 Pool Plumbing Test 504 Gas Test 404 Pre-Gunite 506 Pre -Deck 505 Pool Fencing/Alarms/Barriers 503 Pre -Plaster 507 Manufactured Homes Setbacks 131 Blockin /Unde inin 612 Tiedown/Soft Set System 611 Permanent Foundation System 613 Underground Electric 218 Sewer 407 Underground Water 417 Manometer Test 605 Continuity Test 602 Skirting/Steps/Landings 610 Coach Info Manufactures Name: Date of Manufacture: Model Name/Number: Serial Numbers: Length x Width: Insignia: Finals Public Works Final 538.7681 Fire De artment/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final "PROJECT FINAL *Project Final is a Certificate of Occupancy for (Residential Only) PERMITS BECOME NULL AND VOID 1 YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A 1 YEAR RENEWAL 30 DAYS PRIOR TO EXPIRATION Carbon. monoxide alarms required, by Sections R31.5.1 and R315.2 shall be. installed in the_ following locations: 1 Outside of each separate dwelling unit sleeping area in the immediate vicinity of the bedroom(s). 2. On every level of a dwelling unit including basements. 8315.1.5 Multiple -purpose alarms: Carbon monoxide alarms combined with smoke alarms shall comply with Section. R315, all applicable standards, and requirements for listing and approval by the Office of the State Fire Marshal, for smoke alarms. Butte County's Interpretation of 2013 CRC, Sections 314 & 315 for Smoke Alarms & Carbon Monoxide Alarms: Where alterations, repairs or additions exceeding $1,000 in valuation, existing dwellings shall be retrofitted with smoke alarms and those that have attached garages or fuel -burning appliarces shall have carbon monoxide alarms installed. Existing smoke alarms can be replaced with dual funct_mn alarms for Smoke and Carbon Monoxide and in most cases will comply with the aforementioned cc& requirements for Carbon Monoxide Alarms. DECLARATION OF INSTALLATION UNDER THE PENALTY OF PERJURY As Owner/Contractor, i/we affirm and declare under the penalty of perjury, under the laws of the State of California, by our signatures below as Owner/Contractor, that 1/we will comply prior to final inspection with Items A & B as specified herein: A. Both Owner/Contractor have read and clearly understand the aforementioned 2010 California Residential Code (CRC) Carbon Monoxide Alarm requirements. B. Both Owner/Contractor are responsible for installing Carbon Monoxide Alarms prior to final inspection as per the aforementioned building code and maintaining surh installation. Smoke Alarms will also be installed prior to final inspection -as par the 2010 CRC: Smoke and Carbon Monoxide alarms are now installed in the following locations: 6e.,) c ~S E,+ate e��n 1 �• J Ste+ C �_l�,e(r,�vw Owner's name (print): Owner's signature: Contractor's name (prin _Date: ZKV CSLB License: i'gm 703 1 Contractor's signature: ? Date: 47-1,V-17 Project Address: _gZ,3i 4,4w LW_e',:n C4- Permit #: Page 2 of 2 Butte County Department of Development Services FORM NO �- PERMIT CENTER 7 County Center Drive, Oroville, CA 95965 DBI -01 Main Phone (530) 538-7601 Fax (530) 538-7785 w•A•.o bc:TCOUnc;•.ncc&L Declaration ®f Installation for Smoke Alarms and Carbon Monoxide Alarms The newly adopted 2013 California Residential Code requires the installation of Carbon Monoxide Detectors in dwelling units and in sleeping units within which fuel -burning appliances are installed and in dwelling units that have attached garages. The policy for Carbon Monoxide Alarms in Butte County states: "Any permit obtained in which the value of work exceeds $1000 associated with a Residential Group R Dwelling Unit or Sleeping Unit shall conform to the following 2013 California Residential Code requirements for Smoke and Carbon Monoxide Alarms (Section R314 & R315)." 2013 California Residential Code requirements for Carbon Monoxide Alarms:_ 8315.1 Now construction: An approved carbon monoxide alarm shall be installed in dwelling units and in sleeping units within which fuel-buming appliances are installed and in dwelling units that have attached garages. 3315.1.2 Rower supply: For new construction required carbon monoxide alarms shall receive their primary power from the building wiring where such wiring is served from a commercial source and shall be equipped with a battery back-up. Alarm wiring shall be directly connected to the permanent building wiring without a disconnecting switch other than as required for over - current protection. Ekceptions: 1. In dwel ling units where there is no commercial power supply the carbon monoxide alarm maybe solely battery operated. 2. In existing dwelling units a carbon monoxide alarm is permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. 8315.1.3 Interconnection. Where more than one carbon monoxide alarm is required to be installed within the dwelling unit or within a sleeping unit the alarm shall be interconnected in a manner that activation of one alarm shall activate all of the alarms in the individual unit. Exception: 1. Interconnection is not required in existing dwelling units where repairs do not result in the removal of wall and ceiling finishes there is no access by means of attic, basement or crawl space and no previous method for interconnection existed.. 8315.2 Where required in existing dwellings: Where a permit is required for alterations, repairs or additions exceeding one thousand dollars ($1,000), existing dwellings or sleeping units that have attached garages or fuel -burning appliances shall be provided with a carbon monoxide alarm in accordance with Section R315.1. Carbon monoxide alarms shall only be required in the specific dwelling unit or sleeping unit for which the permit was obtained. R315.2.6 Alarm requirements: No person shall install, market, distribute, offer for sale or sell any carbon monoxide device in the State of California unless the device and instructions have been approved and listed by the State Fire Marshal. Page t of 2 PROJECT OWNER: • ` HARD, KEITH 4237 KATHY LN ` CHICO, CA 95973 APN:047-300-112 PH#:530.520.2072 EMAIL:resquepilot@gmail.com CONTRACTOR: - 'ALTERNATIVE ENERGY SYSTEMS INC. 13620 HIGHWAY 99 CHICO, CA 95973 ` CSLB: 853351 C-10, C-46. BUILDING JURISDICTION: BUTTE COUNTY :DEPT. OF DEVELOPMENT SERVICES - , 7 COUNTY CENTER DRIVE OROVILLE, CA 95965 OFFICE#: (530) 538-7601 FAX#: (530) 538-2140 MON-FRI 8AM-3PM INSPECTION LINE: (530) 538-4365 REQUESTS PHONED IN BY 2PM WILL BE INSPECTED THE NEXT BUSINESS DAY = o S HARD, KEITH o o r 4237 KATHY, LN y N DAD CHICO, CA 95973 n Z o- APN:047-300-112 PH#:530.520.2072 4 Q SCOPE: INSTALL PHOTOVOLTAIC SOLAR SYSTEM ON A TRUSS ; ROOF, MOUNTED IN ACCORDANCE WITH ALL APPLICABLE BUILDING CODES SPECIFICALLY. REFERENCING THE 2016 CALIFORNIA. ELECTRICAL CODE/ 2014 NEC USING THE FOLLOWING SPECIFIC EQUIPMENT: 1..MODULES: SUNPOWER ;- (20) SPR -X21 -345 -D -AC . 6.901<W.SYSTEM , 365 SQFT COVERED 2. INVERTER(S): SUNPOWER: r (20) MODULE INTEGRATED 320W EACH - SITE MAP 13620 HWY 99 Energy For VIfe CHICO, CA 95973 PHONEM 5 FAX#: (5308923i5-6980" 80 . 2360 f Alternative Energy Systems Inc. - - design@ sola renergyforlife.com' ` s cell PAGE # CONTENT PV -1.0 . SCOPE PV -2.0 SITE PLAN `• ` ARRAY LAYOUT ' PV -4.0 �'_, ELECTRICAL DIAGRAM .PV -4.1 rLABEL DIAGRAM *' PV -5.0: GENERAL NOTES ATTACHMENT MODULE SPECS - ` INVERTER SPECS ` 4 RACKING SPECS r, WIRE CALCS r 13620 HWY 99 Energy For VIfe CHICO, CA 95973 PHONEM 5 FAX#: (5308923i5-6980" 80 . 2360 f Alternative Energy Systems Inc. - - design@ sola renergyforlife.com' ` s - 1 r t AirN w J SITE PLAN, ^o HARD KEITH 13620 HWY 99 Energy For Life CHICO, CA 95973 m G D a o 4237 KATHY LN PHONE#: (530) 345-6980 s IV =p = CHICO, CA 95973 D i W z a n 01720 FAM (530) 892-2360 zAPN:047-300-112 PH#:530.520.2072 Alternative Energy Systems Inc. x o - design@solarenergyforlife.com ..- (E) CQ.MPOSITION'ROOF`W/WOOD TRUSSES ' ---�-- -� - MODM AND ROUTER; LOCATION. ,PGE YL.ER; 8i 3 "" r - E MAIN 5, (_) __f7 PANEL JU T _) RESIDENCE -.•••- C BUTIOJPANEL- �,- (N)FADISTRI B (N) MONITORING { El 0 .> V t .y..wr .7' .4 f - 1 r t AirN w J SITE PLAN, ^o HARD KEITH 13620 HWY 99 Energy For Life CHICO, CA 95973 m G D a o 4237 KATHY LN PHONE#: (530) 345-6980 s IV =p = CHICO, CA 95973 D i W z a n 01720 FAM (530) 892-2360 zAPN:047-300-112 PH#:530.520.2072 Alternative Energy Systems Inc. x o - design@solarenergyforlife.com • c 5 1" ATTACHMENTS MAX 72" OC61-011 x ° 4 ' RAFTERS 24" OC . r. • T7 a a -ar 31 0 . ,1 ,,;: ._, l •. .• FIRE CODE. _ N LLUJJ O o oLyj v jv� ♦ o ' ♦ .I -r A' - . .. t ' � ,a' is 'r 13'-10" 20'-10' JUMPER LEGEND 3 DIRECT 5' PR El in- DD rl • NOTES 1.ALL ROOF PENETRATIONS - ..TO BE 72 O.C. MAXIMUM.. • • w T ARRAY LAYOUT' m ^o aHARD;'KEITH S - Energy For 13620HWY99 a• CHICO,CA95973 ' z '3 4237.KATHY N p" o s ' j ®® PHONE#: (530) 345 6980 ' z CHICO' �'CA 95973 ' '� �� FAX#: (530) 892-2360 �" APN:047-300-112 PH#:530.520.2072 _ Alternative Energy Systems Inc. design@solarenergyforlife.com n . - • • - - - + a `' ' (8) PV MODULES/INVERTERS AC -2 AC -1 HARD, KEITH (1) 3/4" EMT w/ ON ROOF w/ (3) #8 THWN-2 CU. & (4) TRANSITION_ CABLE(S) 20A (1) #10 THWN-2 CU. GRD. WIRE RUN: 5' AC -1 WIRE RUN: 10' _ IMP: 20A (2) #10.2 WIRE NM CABLE CU. . IMAX: 33A - WIRE RUN: 30' p G 1P IMAX: 20A (8) PV MODULES/INVERTERS m p SUNPOWER:SPR-X21-345-D-AC HARD, KEITH a< 1.33A/1P/240V D` p 0 20A 3 s 1 1P D p D o 240V 20A p G 1P 240V (12) PV MODULES/INVERTERS J -BOX SUN POWER: SPR -X21 -345 -D -AC - 1.33A/1P/240V 15A - 1P P240V _ (N)AC DISTRIBUTION PANEL 125A/ 1P/ 240V AC -MONITORING (1) 1/2" EMT w/ (2)#14 THWN-2 CU.& (1)#14 THWN-2 CU. GRD. WIRE RUN: 10' CAT -5 SUNPOWER �F� PVSSX �— i( MONITORING — s - ' � I � ROUTER SERVICE VOLTAGE - 20 = L2=2 0 120V=N-L2-L3=NAV NAV=N-L3-LI-NAV I (E) AC SERVICE PANEL 20OA/ 1P/ 240V SCIR: 10000 METER#:1007461222 ELECTRICAL DIAGRAM 13620 HWY 99 Energy For Life CHICO, CA 95973 PHONE#: (530) 345-6980 z Alternative Energy Systems Inc. FAX#: (530) 892-2360 design@solarenergyforlife.com m p m HARD, KEITH a< D` p 0 4237 KATHY LN 3 s D p D o CHICO, CA 95973 p G APN:047-300-112 PH#:530.520.2072 • SERVICE VOLTAGE - 20 = L2=2 0 120V=N-L2-L3=NAV NAV=N-L3-LI-NAV I (E) AC SERVICE PANEL 20OA/ 1P/ 240V SCIR: 10000 METER#:1007461222 ELECTRICAL DIAGRAM 13620 HWY 99 Energy For Life CHICO, CA 95973 PHONE#: (530) 345-6980 z Alternative Energy Systems Inc. FAX#: (530) 892-2360 design@solarenergyforlife.com " - PVARRAY - - fGDISCO N CT S ' MAIN- ' - • .. SUB PANEL } METER , Y � • ' ! . • ..♦ T, - t.. ' • - vHn^'gse mw�se . rt 4 i • 4 . I s y + � • . '- t �h. ,wr ~M'- •4 f.-• -a ,. • - AMPS _ PHASE + + VOLTSKW SOLAR _ WARNING UTILITY INTERACTIVE POWER FLOWING THROUGH THIS PANEL - w GENERATOR _t ; •AC OPERATING WARNINGWITH — ♦ r RAPIDPHOTOVOLTAIC SYSTEM EQUIPPED DUAL POWER SUPPLY .. PHOTOVOLTAIC PER NEC 690.54 Interactive Point of Interconnectin installed at all Electrical Per NEC 705.10, Point of Connection, Distribution Panel covers that porvide a Located On Main Service Panel., F`•. + ' • . v' ,path from PV to Utility.FOR UTILITY AC PHOTOVOLTAIC DISCONNECT r T - OPERATION . Per NEC 690.14, Disconnection means at ' the single AC Disconnect or Main Breaker. SOLAR DO BREAKER RELOCATE a • Solar breaker lahel @ any breaker passing - } ` Bi -Directional Power • ► .. - LABEL DIAGRAM n v v • - ' ' 13620 HWY 99 - HARD KEITH• 0 m Energy FO95973 CHICO, CA ' v' Z Z 3 4237 KATHY LN (�o • .� 0 o , '",PHONE#: (530) 345'69803 a Z ° _ , m CHICO, CA 95973 - r m g v . ` Alternative Ener Systems I �, FAX#: (530) 892 2360 F. t A v APN:047-300-112 PH#:530.5202072' ; e gy_tiY.•, design@solarenergyforlife.com ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE 2014 NATIONAL ELECTRIC CODE (NEC), OR LOCAL MUNICIPAL CODE, AND FIRE DISTRICT REGULATIONS. 1. ALL EQUIPMENT SHALL BE LISTED AND LABELED PER RECOGNIZED ELECTRICAL TESTING LABORATORY AN INSTALLED PER THE LISTING REQUIREMENTS AND THE MANUFACTURER'S INSTRUCTIONS. 2. ALL INVERTERS SHALL BE IEEE 929 COMPLIANT AND SHALL BE INSPECTED BY LOCAL UTILITY BEFORE COMMISSIONING, TESTING, AND OPERATION OF THE SYSTEM. 3. ALL OUTDOOR EQUIPMENT SHALL BE MINIMUM NEMA 3R, INCLUDING OUTDOOR MOUNTED TRANSITION BOXES, COMBINER BOXES, AND SWITCHES. 4. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ART.250,690. 5. NEC. ART. 690.9(A). ALL CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE OVERCURRENT DEVICES LOCATED SO AS TO PROVIDE OVERCURRENT PROTECTION FROM ALL SOURCES. 6. NEC ART. 690.18. DUE TO THE FACT THAT PV MODULES ARE ENERGIZED WHENEVER THEY ARE EXPOSED TO LIGHT, PV CONTRACTOR SHALL DISABLE THE ARRAY DURING INSTALLATION AND SERVICE BY SHORT CIRCUITING, OPEN CIRCUITING, OR COVERING THE ARRAY WITH AN OPAQUE COVERING. 7. PHOTOVOLTAIC SYSTEM SHALL BACKFEED THE DISTRIBUTION SYSTEM ON SITE PER THE REQUIREMENTS OF NEC ART.690.64(B). ALL BACKFEED BREAKERS SHALL BE IDENTIFIED AS SUCH AND SHALL BE SECURED IN PLACE BY ADDITIONAL FASTENER PER THE REQUIREMENTS OF NEC 408.16(F) (408.36 IN 2014 NEC. 8. FALL ARREST PROTECTION PER OSHA REQUIREMENTS SHALL BE PROVIDED FOR ALL ROOF WORK. 9. ALL CONDUCTORS AND TERMINATIONS SHALL BE RATED FOR 75" C MINIMUM. 10. NEC ART. 690.14. -SEE SHEET RE -4.1 FOR LABEL DIAGRAM 11. NEC ART. 690.53. -SEE SHEET RE -4.1 FOR LABEL DIAGRAM 12. NEC ART. 690.17. EACH AC DISCONNECT SHALL ALSO BE LABELED WITH: "WARNING! -ELECTRICAL SHOCK HAZARD -DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIZE MAYBE ENERGIZED IN THE OPEN POSITION". 13. GROUNDING OF ALL DWELLINS SHALL BE CONFIRMED. 14. CONTRACTOR TO PROVIDE GROUND FAULT PROTECTION FOR ROOF MOUNTED PHOTOVOLTAIC ARRAYS LOCATED ON DWELLINGS PER 2011 NEC ART.690.17. 15. WHERE MORE THAN ONE NOMINAL VOLTAGE SYSTEM EXIST, THE DIFFERENT SYSTEMS SHALL BE IDENTIFIED BY PHASE AND SYSTEM PER 2014 NEC ART.210.41) 16. PROVIDE AN ACCESSIBLE DISCONNECT DEVICE THAT IS LOCKABLE IN OPEN POSITION AND IS LOCATED WITHIN 10'-0" OF THE METER PER LOCAL ELECTRICAL UTILITY REGULATIONS. 17.- PHOTOVOLTAIC SOURCE CURRENTS MUST BERATED AT BOTH 125% OF THE PARALLEL MODULE AND AT A CONTINUOUS LOAD OF ANOTHER 125% FOR TOTAL OF 156% OF THE LOAD. 18. PROVIDE PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECT MEANS IF THEY ARE NOT IN THE SAME LOCATION PER 2014 NEC ART.690.56. 19. INSTALLATION OF PV PANEL ARRAYS SHOULD RESIST SLIDING AND POP-UP RESULTING FROM SEISMIC EVENTS AND SHOULD COMPLY WITH CBC SECTION 1613A AND ASCE STANDARD 7-05, CHAPTER 13. 20. PV SYSTEM INSTALLER WILL BE RESPONSIBLE FOR FURNISHING AND INSTALLATION OF ALL RELATED EQUIPMENT, CABLES, ADDITIONAL CONDUITS, BOXES WIREWAYS AND OTHER ACCESSORIES NECESSARY FOR COMPLETE AND OPERATIONAL PHOTOVOLTAIC SYSTEMS. 21. PV SYSTEM CONTRACTOR SHALL COORDINATE ALL THE WORK WITH THE ENGINEER, THE CONSTRUCTION MANAGER AND ALL OTHER CONTRACTORS TO ENSURE THAT PV SYSTEM IS INSTALLED AS SPECIFIED IN THESE DRAWINGS. 22. DRAWING IN GENERAL OR DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF THE EQUIPMENT AND WORK INCLUDED. THE INTENTION OF THE DRAWING IS TO INDICATE SIZE, CAPACITY, APPROXIMATE LOCATION AND GENERAL RELATIONSHIP, BUT NOT EXACT DETAIL OR PHYSICAL PLACEMENT. 23. FIELD VERIFIES EXACT AIC RATING REQUIRED OF THE MAIN SWITCHBOARD FROM LOCAL UTILITY. 24. A PV SYSTEM WITH MULTIPLE INVERTERS, WHERE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, WILL HAVE A DIRECTORY CREATED FOR EACH LOCATION. AS PER 2014 NEC 690.5(H) AND IN ACCORDANCE WITH 2014 NEC 705.10. 25. A NON FOLDING LADDER WILL BE IN PLACE AND SECURED TO THE ROOF TO PROVIDE ACCESS FOR ALL INSPECTIONS. ALL BOXES WILL BE OPENED UPON REQUEST. 26. SMOKE AND CARBON MONOXIDE ALARMS WILL BE INSTALLED IN ACCORDANCE WITH CRC R314 R315 n m n o m L. 0 a m HARD, KEITH 13620 HWY 99 Energy For Life CHICO, CA 95973 G E z K 4237 KATHY LN PHONE#: (530) 345 6980 /� o Z Z _ ° D 8 D S o m CHICO, CA 95973 ; �a FAX#: (530) 892-2360 MM p ° APN:047-300-112 PH#:530.520.2072 Alternative Energy Systems Inc. design@solarenergyforlife.Com a Letter of Equivalency Type C to Type ®AC Modules • June 22, 2017 ' . r - i+..Y.- z, : To Whom it"May Concern, - In order to meetfuture advanced grid requiremrents, SunPowerm is transitioning from Type C AC modules'to Type D -AC'- module's. The purpose of'this.letter is to demonstrate the mechanical and electrical equivalency of Type C AC modules .' and Type D AC modules.,Type D'AC'modules are drop-in replacements for Type C AC modules and are available _at t �. same DC and AC power levels. Type'D AC modules have the same form, fit, and function as Type C AC modules. The -AC 3 y ' electrical output specifications of Type.0 AC modules and Type C AG modules are equivalent, ensuring intercharigeability = for AC conductors, overcurrent protection devices, and grounding. A A SunPower Type D AC modules are certified per UL 1741 SA to the following SRDs: IEEE 1547, IEEE 1547a,,and CPUC Rule- 21 Phase 1. These 'additionaI certifications and functionality enable Type D AC modules to meet California CPUC Rule 214"% Phase 1 smari'inverte'r requirements. The following table lists the Type.0 AC module models and their' respective Type D-; + r ` equivalents,' as of the date of this letter: E19 -320 -C -AC E19 -320 -D -AC ' } . E20 -327 -C -AC =. E20 -327 -D -AC X21-335-BLK-C-AC X21-335-BLK-D-AC X21 -335 -.0 -AC ' ' X21435 -D -AC , X21 -345 -C -AC ; ''" X21'345 -D -AC X22 -360 -C -AC. ;: X22 -360 -D -AC Where Type D AC modules are substituted"in the field for.Type C AC;moclules, no changes to the physical layout,+structural loading, electrical design, or interconnection are.required. Should -you have any questions or concerns, -'lease' contact SunPower Technical Support at 1-8.00-786-7693. Best Regards, + ' • Matt Mayberry `', > 4 � ' • • } • -. � _ - " � _ _' , • a • ' - • . '� Director, R_esidenti.al•Product Management " ► r I. t' . - - •. .tom . r . s -• a .. . y A ' rt Design -Driven Advantages } #1 module aesthetics and efficiency' Unmatched module.reliabilityz i No electrolytic capacitors 25 -year Combined Power and Product Warranty California Rule 21 Phase 1 compliant Maximize Value for Roof Size system for roof, not string inverter i Optimize performance of each module Expand Deployment Options Complex roofs and partial shading Small systems System expandability Simplify & Speed Installation Factory -integrated microinverter Robust, double -locking AC connectors Design flexibility offsite and onsite r No DC string sizing process Fewer installation steps than competing systems Intuitlive commissioning Component of Complete System Built for use with SunPowerP I nvisi Mount"' and the SunPower Monitoring System (PVS5x) Superior system reliability and aesthetics X .SERIES Optimize System and Installation Efficiency, SunPower' AC modules, which include a Factory-iniegrated SunPower - microinverter,.prov de a revolutionary combination of high efficiency,, high reliability, and moduledevel DC -to -AC power conversion. Designed " } specifically for use with SunPower InvisiMouncl and the SunPower; Monitoring System, SunPower AC modules -enable rapid installation,,be! in -class system aesthetics, and intuitive visibiliy into system performance. All this comes with the best Combined Power and Product Warranty in the industry. Grid Support Utility -Interactive Smart Inverter SunPower's new Type D AC module is UL tested and certified to UL 1741 SA and provides advanced smart inverter functions. SunPower Type D AC modules are fully compliant with the California Rule -21 Phase 1 requirements, and the Rule 21 and profile is easily set during commissioning with SunPower PVS5x monitoring hardware: sunpower.com Datasheet S U N P O W E R® a, X .SERIES Optimize System and Installation Efficiency, SunPower' AC modules, which include a Factory-iniegrated SunPower - microinverter,.prov de a revolutionary combination of high efficiency,, high reliability, and moduledevel DC -to -AC power conversion. Designed " } specifically for use with SunPower InvisiMouncl and the SunPower; Monitoring System, SunPower AC modules -enable rapid installation,,be! in -class system aesthetics, and intuitive visibiliy into system performance. All this comes with the best Combined Power and Product Warranty in the industry. Grid Support Utility -Interactive Smart Inverter SunPower's new Type D AC module is UL tested and certified to UL 1741 SA and provides advanced smart inverter functions. SunPower Type D AC modules are fully compliant with the California Rule -21 Phase 1 requirements, and the Rule 21 and profile is easily set during commissioning with SunPower PVS5x monitoring hardware: sunpower.com Datasheet S U N P O W E R® ' Operating Temp. P •s �. Max. Ambient Temp., ,,SPR -X21 -345 -D -AC SPR -X21 -345 -D -AC - t IEEE 1547a-2014 CA Rule'213 ^ SRD Profile 21.5% 21.0% (default settings) min./ /max. ShadeT6lerance Three bypass•diodes ."Integrated module -level maximum power point •.. tracking- . . ruin. / nom: / max: Frequency (Hz) z UL 6703, UL 9703 Connectors and cables ; 59.5 / 60.0 160.5 58.5 / 60.0 / 60.5' ;- Power Factor a . 0.99 / 1:00 /.1;00. - 0.85 lead.'/'1.00 / 0,85 lag. " Reactive Power , ' ' -NEC 690.6. - -169 Var. , outside the array) --Volt-VAr _ Volta - .. , @240 V, ,: 211.2 ! 240 / 264 V When used with InvisiMount racking (UL 2703): @208 V i 831208 / X28:8 V Max. Curretjt ' • @240 V 1,33 ? • _ ' • _ @208 V 1.54 A OCIP;C CEC Conversion Efficiency @240 V 96.0%,@208 @208 V 95.5%. Max: Units`Per20 A Branch Circuit •@240. V 12 (single phase) @208 V" 10 (two pole)+wye ' Power,,-:. 320 W320 VA • ' No active phase balancing for phase installations • �` ' Operating Temp. P •s �. Max. Ambient Temp., ,,SPR -X21 -345 -D -AC SPR -X21 -345 -D -AC Nominal Power4 (Pnom) :` 345 W 335 W Power Tolerance -5/-0% , +5/-0% Avg. Panel Efficiency 21.5% 21.0% Temp. Coef. (Power) -0.29%/°C ShadeT6lerance Three bypass•diodes ."Integrated module -level maximum power point •.. tracking- . . ' Operating Temp. '• O•' • • • ter-$ , F r ' -40':F to +185° F,(-40° C to +85° C) Max. Ambient Temp., 122° F (500 C) . 11Load Wind; 62 psf 3000 Pa, 305 kg/rn ;front -back Snow: 125 psf, 6000 Pa, 611 kg/m'- front Impact Resistance 1 inch (25 -mm) diameter hail at 52 n]ph (23 m/s) 'Highest of over 3,200 silicon solar panels, Photon Module Survey,, Feb.2014 =1 rank in "PV Module Durability Initiative Public Report," Fraunhofer CSE, Fell 2013. Five out of the top eight largest manufacturers were tested. Campeau, Z.•et al."SuriPower Module Degradation Rare,' SunPower white paper; Feb 2013. See www.sun`power.com/facts for details. Factory set to 1547a-2014 defauli'sedings. CA Rule 21 default settings profile set during commissioning. See the Equinox lnstallodon Guide #518 for more information. 'Siandard Test Conditions (1000 W/m2 irradiance, AM 1.5, 250 C): NREL calibration standard: 'OMS current, LACCS FF and voltage. P.II DC voltage is fully contained within the module. 'Based on average of measured power values dui ina r)roduction. r See wwwsunpower.com(facis for more reference information. For more details, see extended datasheet: wiww.sunpower.comldacesheets. . 5 ME 7 777777777, Solar Cells 961vionocrys0line Maxeon Gen III Front Glass -Nigh-transmission:tempeeed glass with and - reflective coating Environmental ;Rating Outdoor rated Frame Class 1 black anodized (highest AMNIA rating) Weight 45.5 lbs (20,6,kg) Recommended'Max. Module Spacing 1.3 in. (33 mm) F 'Highest of over 3,200 silicon solar panels, Photon Module Survey,, Feb.2014 =1 rank in "PV Module Durability Initiative Public Report," Fraunhofer CSE, Fell 2013. Five out of the top eight largest manufacturers were tested. Campeau, Z.•et al."SuriPower Module Degradation Rare,' SunPower white paper; Feb 2013. See www.sun`power.com/facts for details. Factory set to 1547a-2014 defauli'sedings. CA Rule 21 default settings profile set during commissioning. See the Equinox lnstallodon Guide #518 for more information. 'Siandard Test Conditions (1000 W/m2 irradiance, AM 1.5, 250 C): NREL calibration standard: 'OMS current, LACCS FF and voltage. P.II DC voltage is fully contained within the module. 'Based on average of measured power values dui ina r)roduction. r See wwwsunpower.com(facis for more reference information. For more details, see extended datasheet: wiww.sunpower.comldacesheets. . a�'• Class Afire rated PID Test Potential -induced degradation free 280 M <� i [11.02 In] - 1107 mm [43.6 In] 10x6 mm E0D 1 [41.2 In] i n2m1 NrEtACWE 1558 mm 16131n] - I - ® wENm swmowN Y.j LISTED 6oa�o . Please read the safety and installation instructions for details. Module Fire Pe [wmence: Type 2 i 518932 RevB • o Warranties 25 year limited power warranty 25 year limited product warranty UL listed to UL 1741 SA SRDs: IEEE 1547-2003, IEEE 1547a-2014, CA ' Rule 21 Phase 1 •1aV Rapid Shutdown -Equipment-. [ +;°2 •IEqulpmentGrounding " UL 6703, UL 9703 Connectors and cables ; " (load break disconnection) -. UL 1741 AC Module (Type 2 fire rating) L Ceaffications Enables installation in accordance with: - -NEC 690.6. NEC 690.12 Rapid Shutdown (inside and - " outside the array) NEC 690.15 AC Connectors, 690:33(A) - (E)(1) FCC and ICES -003 Class B When used with InvisiMount racking (UL 2703): imearated grounding end 'bonding a�'• Class Afire rated PID Test Potential -induced degradation free 280 M <� i [11.02 In] - 1107 mm [43.6 In] 10x6 mm E0D 1 [41.2 In] i n2m1 NrEtACWE 1558 mm 16131n] - I - ® wENm swmowN Y.j LISTED 6oa�o . Please read the safety and installation instructions for details. Module Fire Pe [wmence: Type 2 i 518932 RevB :5unT�omn Module' /Mid Clamp end Fail Module* / End Clamp and Rail Mid Clamp, Eno Clamp - W- s Rail 1 Rail Splice End Cap r , , emperature -40° C to 90' C (-40° F to 194° F) Mex. Load 7400 Pa uplift 5"00 P3 downforce Warrarues Componentblaterrl' Application We ght Mid Clamp Black oxide stainless steel A151304 63 g (2.2 oz) End Clamp Black anodized aluminum 3'10y 5063-i5 1109 (3.35 cz) Rail. Black anod,zed aluminum a'loy 6005-T6 330 g/m (9 o %ft) Rail Splice Aluminum a` c;y,5005-T 5_ .330 g!m (9 0_ ft1 Ground tug Assembly' 304 stain)?ss x. (A2-70 bolt t:n-plated copper lug) 1065 ''m ' (3.7E OZ) ' End Cap 31a_k ace_al (DOM) copoymer 10.4 g (0.37 o_) , emperature -40° C to 90' C (-40° F to 194° F) Mex. Load 7400 Pa uplift 5"00 P3 downforce Warrarues i Compos:ticn Shingle P.after ,'tt3chment Application Compos-ticn Shingle Roc; Decking Attachment Curve? and ='at ode ioor attachment . Certifications Universal Iri er:ace for Cher P.oei Attachments . , emperature -40° C to 90' C (-40° F to 194° F) Mex. Load 7400 Pa uplift 5"00 P3 downforce afar to roof attachment hard.oare manufacturers documental on �f *Nv odule frame that is compatible with L`telmns+Mount system cegdired forb)rdware tnteroperabtlity V MIS SUnPower-Corporidon, All Rights Reserved. SUNPOWER, the SUNPOWER logo. and INVISIMOUNT are trademarks or regtstared trademarks,ot Sun Power Corporation. Alto0ier trademarksa,e the pryperty of their respective owners. sunpcwerCom Specifications included in chis datasheei are suli)ect to change without notice. ) Document 609506 Rev 3 Warrarues 3= -year product warranty , S -year finish warranty UL 2703 Listed Certifications Class A fire rating when distance between roof surface and bott)m of SunPower module frame is s 3.5" afar to roof attachment hard.oare manufacturers documental on �f *Nv odule frame that is compatible with L`telmns+Mount system cegdired forb)rdware tnteroperabtlity V MIS SUnPower-Corporidon, All Rights Reserved. SUNPOWER, the SUNPOWER logo. and INVISIMOUNT are trademarks or regtstared trademarks,ot Sun Power Corporation. Alto0ier trademarksa,e the pryperty of their respective owners. sunpcwerCom Specifications included in chis datasheei are suli)ect to change without notice. ) Document 609506 Rev 3 INVISIMOUNT RACKING DETAIL —SOLAR MODULE END CLAMP sm 11V V1J11'IVVIV I fxl11L CLAMP EACH MID CLAMP GROUNDS THE AIL INVISIMOUNT RAIL I GreenFasten GF1 -Product Guide Installation Instructions with Compression Bracket 2 A 5 Consult an engineer or go to www.ecofastensolar.com for engineering data. 3 4a 4b 4c 1. Locate the rafters and snap horizontal and vertical lines to mark the installation position for each GreenFasten flashing. 2. Drill a pilot hole (1/4"diameter) for the lag bolt. Backfill with sealant. EcoFasten Solar recommends an EPDM mastic. 3. Insert the flashing so the top part is under the next row of shingles and pushed far enough up slope to prevent water infiltration through vertical joint in shingles. The leading edge of flashing must butt against upper row of nails to prevent turning when tourqued. See page 2.2 for vertical adjustment when leading edge of flashing hits nails in upper shingle courses. 4. Line up pilot hole with GreenFasten flashing hole. 4a Insert the lag bolt through the EPDM washer, the top compression component bracket (L- 102-3, L-102-6*, SCL-101-3*, Z-101 *, Conduit Mount Bracket*) and the gasketed hole in the flashing and into the rafter. 4b Insert the lag bolt through the EPDM washer, the Comp Mount Slide compression bracket and the gasketed hole in the flashing and into the rafter. 4c Insert the lag bolt through the SS washer, the third -party bracket, the EPDM bonded washer, the CP -SQ -Slotted compression bracket and the gasketed hole in the flashing and into the rafter. 5. Torque:The range is between 100-140 torque inch -pounds depending on the type of wood and time of year. The visual indicator for proper torque is when the EPDM on the underside of the bonded washer begins to push out the sides as the washer compresses. If using an impact wrench to install the fasteners be careful not to over torque the fastener. You may need to stop and use a ratchet to finish the install. F *not pictured. 877-859-3947 EcoFasten Solar"' All content protected under copyright. All rights reserved. 7/24/2014 EcoFasten Solar products are protected by the following U.S. Patents: 8,151.522 B2 8,153,700 132 8.181,398 B2 8,166,713 B2 8.146.299 B2 8.209.914 B2 8,245.454 B2 8,272.174 B2 8,225.557 B2 2.1 GreenFasten1. GF1 — Product Guide . Slide flashing up under shingles until leading edge engages nails. Measure remaining distance to adjust upslope. - • Nails beneath shingle Installation Instructions Use for vertical adjustment when leading edge of flashing hits nails in upper shingle courses 2. Remove flashing and cut "V" notch at marks where nail shafts engaged leading edge of flashing the distance desired in Step 1. Notch depth 00 40 00V r �sarealeading edge Nails beneath shingle��'�Nails beneath shin le Arr s ' •,j.t r � n ? 4 r. ,6r � ,+, �� �* 'ft' i yY � sS.r` �`�^n . " � s � n R �� t4•`1Fr-• Y T.iey, .,,,r„�„ �tS. F� .At+'' ),71� i �44�� �1 i � I �.P,�'-. � .� �'} ;.•r�� •Y � �tRk� 5i�(' 3�� .t��Y 'S': >n4 x•t .ti ,vt t � 4 '�� ,!."X''„` !"., a+.,.,H '`S� y �+�'� �> J¢ r rs�"*•�?Z x�, �„•, y ... n + +i.}�..5�,'r�K. 1+k � y 'y orf 1'R ���d1i •0•� �� ,fr` � 'se.;r �j. n .� s � ® • �•y t,���,�,c.��� ,*a.t1%A+T4{ �x r}t�k � n�`.ai.X��t�"f 3'. x�r 2"x ,�~YN�'��i;,a �.�y ��i a ,r i�x.,�'Y�et�'�� '•r � y,. '��.'a y. �r"1 �,,.r�r'��� �>..,ji itfi "1r". -- �wi: +j�a�;�i � y` nr>'r-•+4; �•L,��r��fl tpt`V f� �}'`tiN'S' � � nC:.t�,���t+r .:.a- �ro¢syia�'r3-t ff f;"sE� ,�.,.�}7«�rf,� }�' •� + xiF`i..i't„�? 1. h L877-859-3947 EcoFasten Solar8'AII content protected under copyright. All rights reserved. 7/24/2014 2.2 EcoFasten Solar products are protected by the following U.S. Patents: 8.151.522 B2 8,153.700 B2 8,181.398 B2 8.166.713 B2 8.146.299 B2 8.209.914 B2 8.245.454 B28.272.174 62 8.225.557 82 GreenFasten'" GF.1 - Product Guide - Cut Sheets:.GF1 ..f ':P �� 1. • 9 • � - - tA• _ is � � r--1°_ i - i - " � .' Al -SECTION A -A r Y i ` 877=859-3947 EcoFasten Sol@&All content protected under copyright. All rights reserved. 7/24/2014 J ' . jw 3.1' EcoFasten Solar products are protected by the Followino U.S. Patents: 8,151,522 82 8,153,700 B2 8,181,398 B2 8,166,713 B2 8,146.299 B2 8,209,914 B2 8.245.454 B2 8.272.174 B2 8,225.557 B2 GreenFasten" GF1 - Product Guide Cut Sheets: GF1, 812 8"3. R 8' 1/32"± OT 16 s s,j'�i , w ,,., , • —rl - 5%64 16 DETAIL A 4„ SCALE: 2:1 Finish Options♦ �\` �r�::31, F • BILK = Matte Black PP �• ♦ • MLL ='Mill Finish fl. -/ ❑ 1' � `' . ` .. -• 1 .. .� .. �. a..A . ..•..ate .. .. �a. ..... ,� , �• ►t i, ` 877.859-3947 EcoFasten Solar"All content protected under copyright. All rights reserved. 7/24/2014 3.2 EcoFasten Solar products are orotecled by the following U.S. Paients: 8,151.522 132 8,153,700 132 8,181,398 H2 8.188,713 132 8,148.299 82 8.209,914 132 8,245,154 82 8.272,174 132 8,225.557 82 GreenFasten" GF1 - Product Guide' - Cut Sheets: Bracket Options - CP -SQ -Slotted .r 4 r . it ! .06 — — .50 — t1r i� i1 #� ,. .38 2.00 .1.00. • �—• � '� t' rl J 1.00 0 0.38±.00 Z 0.50 t �\/0 0.88±; O l X 82' 2.00 — —1— tit tit r !F• �. r 877-859-3947 EcoFasten Solar" All content protected under copyright. All rights reserved. 7/24/2014 3.3 sr EcoFasten Solar products are protected by the following U.S. Patents: 8.151,522 B2 8.153.700 132 8.181,398 B2 8,166,713 132 8,146,299 132 8,209,914 B2 8,245.454 B2 8,272,174 B2 8,225,557 132 � ` , GreenFasten~GFl-Product Guide Cut�heet�8racket' C)'tions �SC�]Ol-3" ' . � . . '46 SERRATIONS1016,1 71R.0 10 � ^' ' . �. 60.00 3/8 .002 SCALE 1.1. pl� '877-859-3947 E^"'a"=^""='All content protected under copyright. ""'a"=res="e" "^°2" ° xouui*o�y azo�oum*aoo��o�s au ` ' B2.8,225.557 B2 3.5 ' -___.----__-----_--U.S.-'-_---Patents:--`_-522 _--_---''-_--398 ----'- 8,272.174 ' ' . . 1 GreenFasten",GF1 -Product Guide 46 SERRATIONS t Cut Sheets: Bracket Options - L-102-3 -2X 3/8" • t i. � .. - _ it �, •- N X N R 1'% 16"' _ / 00 1/16" R.005 LO IN +ir i, R.010„ 2 X R.OI 60.000 , 3�$„+.006 = .002 , + 1 /8” + DETAIL A 0.875 _ .010 X 82 • '� SCALE -3: 1 !F; r+ 877-859-3947 EcoFasten Sola&All content protected under copyright. All rights reserved. 7/24/2014 3.6 EcoFasten Solar products are protected by the followinq U.S. Patents: 8.151,522 132 8.153,700 B2 8,181,398 132 8,166.713 82 8,146.299 B2 8,209.914 132 8,245.454 132 8.272.174 132 8.225.557 62' _ AC Circuit Ampacity Caulator s i M lceter #: 1007461222 Customer Name: HARD, KEITH Location: 4237 KATHY LN, CHICO, CA 9 ' • `Wire Note: AC -1 Description: AC MODULES TO AC DISTRIBUTION PANEL Wire Calculation _Y, UE 3.84 kWatts' 240 VAC Split "Voltage Configuration TRTL Inverter? ,- 10 Minimum -Wire and Conduit Size based on Voltage Drop and Ampacity " 10 Minimum'Ground Size Based on NEC R ', •- `• ' 20.00 A Minimum Ciruit Breaker/Fuse Size al8 Actual Ground Size'Based on NEC . ., 20.Q0 A Ampacity After•Derate 10 Wire Size Based on Ampacity 30 A 0.992 % of Voltage Drop 10 Wire Size Based on Voltage Drop ,' 3Q A 16 A Circuit Ampacity -1 Factor x' i 1 Phases 0.82 Conditions of Use Derate Factor - 19.51 A . Minimum Conductor Ampacity Based on Conditions of Use 20.00 A Minimum Conductor Ampacity Based on 1.25 Rule ` Conditions of Use , 0.82 Derate Total _50 °C Temp Coef (ambient + Sunlight)1]22 'F 0.82 Derate 50 °C Ambient Temp 1°F 3 none Sunlight Exposure . °F 0 °C Temp adder, 3 or less Number of Current Carrying Conductors pp " . p • 1 Derate a lied to Tem Coefficient Voltage Drop; Allowable Tolerance (Solar Generation -1%, Distribution 3%) - 240 V ' Circuit Voltage r 16 A Circuit Amps _ _. 1.24 Resistance 60 ft One Way Distance 1,0 Wire Size 0.992 % of Loss Conduit Size (Conduit Fill Can Not be more than 40%) PVC Conduit Type 0.1§W ire Size Diameter 3% Conduit Fill percentage - 3/4 Conduit Size 0.212 Ground Wire Size Diameter 0,409 Conduit Internal Diameter 600 V System Voltage THWN-2 Wire Type. AC Circuit AmpacityCalculator • -Meter #:1007461222 Customer Name: HARD, KEITH ; Location: 4237 KATHY LN, CHICO, CA 9 _ _ - tip- Wire Note: AC 2 Description: AC DISTRIBUTION PANEL TO MAIN k " Wire Calculation 6.4 kWatts 240 VAC Split Voltage Configuration . TRUE TL In ° 8 Minimum Wire and Conduit Size based on Voltage"Drop and Ampacity - 10 Minimum Ground Size Based'on NEC 33.33 A Minimum Ciruit Breaker/Fuse Size10 Actual Ground Size Based on NEC 5 33.33 A Ampacity After Derate 8 Wire Size Based on Ampacity .. 55 A 0 % of Voltage Drop 10 Wire Size Based on Voltage Drop 30 A t 26.667 A - Circuit'Ampacity ' 1 Factor 1 Phases E33. Conditions of Use Derate Factor - y A Minimum Conductor Ampacity Based on Conditions of Use A Minimum Conductor Ampacity Based on 1.25 Rule Conditions 6Wie .. ~ 0.82 Derate Total 50 °C Temp Coef (ambient + Sunlight) 122, °F 0.82 Derate - 50 °C Ambient Temp 122 °F none Sunlight Exposure*-.--,-, . 3,2 °F _ , 00 °C. Temp adder 3 or less Number of Current Carrying Conductors` IBJ Derate applied to Temp Coeficient , Voltage Drop: Allowable Tolera,rice (Solar Generation 1% , Distribution 3,%) s�. - 240 V Circuit Voltage - 26.667 A Circuit Amps 1,24FResistance, ft One Way Distance 1012 SIZe - 0of Loss Conduit Size (Conduit Fill Can Not be more than 40%) EMT Conduit Type 0.212 Wire Size Diameter 15% Conduit Fill percentage ' _ . 1 Conduit Size_ - 0.16 Ground Wire Size Diameter0,864 Conduit Internal Diameter, .. 600 V' System Voltage ; _ THWN-2 Wire Type