HomeMy WebLinkAboutB17-2092 040-200-083Permit Pack Violic'h Farms Stanford 72kw Ground Mount PERMIT # 2 BUTTE COUNTY DEVELOPMENT SERVICES FIVIUtZ5 REVIEWED FOR CODE COMPLIANCE DATE ---q APN: 040-200-083 Address: 2243 Durham Dayton Hwy Durham, CA 95938 B 17--')0!)2 "ILEW: i "046-20041183 S E r % M J4 .. GRN.D MNTSOLAR.COIN' ol • 0 HIGH PERFORMANCE SOLAR PANELS REC PEAK ENERGY 72 SERIES REC Peak Energy 72 Series panels are ideal for building large-scE le commercial and utility projects while reducing balance of system costs. REC combines leading standards of design and manufacturing to produce long lasting and high performance solar panels with reliable power output. I ri AFF MORE POWER US IMPORT DUTY PER FT' FREE DOC ► \ y P104 FREE �! 100% IREDUCED BALANCE OF PID FREE SYSTEM COSTS REC PEAK -ENERGY,72 SERIES a k 10 year product warranty. C&S, S�® pVE 25 year Iinear power output warranty LISTED C US " (max.degressioninperformance of0.7%p.a.). UL 1703, Fire type 2. CEC listed, IEC 61215 & IEC 61730; IEC 62804 (PID Free), IEC 6:701(5alt Mist Leve 16), IEC 62716 (Ammonia Resistance),15011925-2 (Ignitab il ity Class E), + U NI 8457/9174 (Class A), ISO 9001:2015,15014001,OHSAS18001 46.6"C(±2"C) p EFFICIENCY Temperature Coefficient ofVoc YEAR PRODUCT WARRANTY 25 YEAR LINEAR POWER Back Sheet: OUTPUT WARRANTY qT Y� Anodized aluminum(silver) All measurements in inches - US IMPORT DUTY FREE 21 ft2 0.95 m2) 4mm2 PV wire, 47 47"(1.2 1.2 m) • Connectors: TonglinTL-Cable01/Tonglin-Cable01S-F* 4 ELECTRICAL D. Nominal Power- P,,,.pp(Wp.) 3.0.0 305 3.1.0 315 320 325 Watt Class Sorting -(W,1 ........................................... ........................ .................... -0/+5 ..................................................... 0/+5 0/+5 0/+5 ................................................................... 0/+5 0/+5 Nominal Power Voltage -V,,,ppIV) 36.5 36.9 37.2 - 37.5 37.9 38.5 ........................................... ....................... ......................................... Nominal Power Current-IM;p(A) 8.22 ................................................................................. 8.27 8.34 8.40 ,........._ 8.45. ................... 8.46 -1 ,._..., ..-.............. .-......._,..-.......... ................................................................................. Op en Circuit Voltage -Voc(V) . ` 44.9 45.2 - 45.5 .............................. 45.8 46.1 ................. 46.4 .................:.................. .................................................................... " Short Circuit Current -Rc(A) > 8.76. ,........................................................................... . 8.82 8.88 . 8.93 ' ..................... . 8.99 9.05 .............................................................................................................................................................................................................. Panel Efficiency (9/6) 15.4• 15.6 15.9 .16.2 16.4 16.7 ..............................................................................,.....................,........................................ ................... Measurement tolerance of t3%from nominal values; values at standard testconclitions STC (ainnass AM 15, irradiance 1000 W/m', 25°C cell 'Where root indicates the norrinal power class (P,,) at STC indicated above, and can be followed by the suffix XV for 1500V rated modules. ELECTRICAL DATA CCU NOCT Product Code*: RECxxxPE72 Nominal Power-PMPP(Wp) 217 221 .................................... 225 229 ............. ........... 232 I ............................. 236 . .............. ................................................ Nominal Power Voltage-VMpp(V) 29.9 _ 30.130.4 . 30.6 :............................................................. 30.8 . 31.0 ......................................... _................... ................................................... Nominal Power Curren-IMpp(A) • 7.27 _.'........ 7.34' .................... 7.41 7.48 7.54 7.61 .................................. ........ _................... :......................................................... Open Circuit Voltage-Vac(V) :. 36.9 ................................................... 37.2 ............................................... 37.4 r ................................... 37.6_ ............................................... -...................................... 37.9 38.1 ... ....................................... -................. ........... Short Circuit Current- Isc(A) • • 7.67 7.72 7.77 7.83 7.88 • 7.94 ................... .... _................. _................... .............................. Nominal cell operating temperature NOCT .............. _................................................ (800 W/m', AM 1.5, windspeed :.................................................. 1 m/s, ambient temperature 20"C). 'Where xxx indicates the nominal power class (P„pp) at STC indicated above, and can be followed by the suffix XV for 1500V rated modules. k 10 year product warranty. C&S, S�® pVE 25 year Iinear power output warranty LISTED C US " (max.degressioninperformance of0.7%p.a.). UL 1703, Fire type 2. CEC listed, IEC 61215 & IEC 61730; IEC 62804 (PID Free), IEC 6:701(5alt Mist Leve 16), IEC 62716 (Ammonia Resistance),15011925-2 (Ignitab il ity Class E), + U NI 8457/9174 (Class A), ISO 9001:2015,15014001,OHSAS18001 Nominal Operating Cell Temperature(NOCT) 46.6"C(±2"C) p EFFICIENCY Temperature Coefficient ofVoc YEAR PRODUCT WARRANTY 25 YEAR LINEAR POWER Back Sheet: OUTPUT WARRANTY qT Y� Anodized aluminum(silver) Junction Box: US IMPORT DUTY FREE Nominal Operating Cell Temperature(NOCT) 46.6"C(±2"C) Temperature Coefficient ofP,PP -0.40%/"C Temperature Coefficient ofVoc -0.27%/°C Temperature Coefficient of Isc 0.013%/'C Cell Type: 72 multicrystalline Design Load: 3 strings of 24 cells with 3 bypass diodes Glass: 0.16"(4 mm)solarglass with anti -reflection surface treatment Back Sheet: Highly resistant polyester Frame: Anodized aluminum(silver) Junction Box: IP67 rated 21 ft2 0.95 m2) 4mm2 PV wire, 47 47"(1.2 1.2 m) • Connectors: TonglinTL-Cable01/Tonglin-Cable01S-F* 4 12 AWG (4 mm2) to change without 'Dependent on product type Operational Temperature: -40...176"F(-40...+85"C) Maximum System Voltage: 1000V Design Load: (+) 75.2 lb5/ft2 (3600 Pa)* (-) 33.41bs/ft2 (1600 Pa)* 'Refer to installation manual Max Series Fuse Rating: 20A Max Reverse Current: 20A MECHANICALDATAc c Dimensions: 77.5 x 39 x 1.8 in (1968 x 991 x 45 mm) Area: 21 ft2 0.95 m2) Weight: 59.5 lbs (27 kg) c 4 Note! All specifications are subject to change without notice at anytime. Founded in Norway in 1996, REC is a leading vertically integrated solar energy company. Through integrated manufacturing from ®` REC C silicon to wafers, cells, high-quality panels and extending to solar solutions, REC provides the world with a reliable source of clean ' ^ energy. REC's renowned product quality is supported by the lowest warranty claims rate in the industry. REC is a Bluestar Elkem company with headquarters in Norway and operational headquarters in Singapore. REC employs more than 2,000 people worldwide, producing 1.4 GW ofsolarpanelsannually. » www.recgroup.corn • SUNNY TRIPOWER 12000TL-US /,15000TL-US / 2000OTL-US / 24000TL=US'/ 30000TL-US Design flexibility • 1000 V DC or 600 V DC • Two independent DC inputs • 15 • to 90 • mounting angle range • Detachable DC Connection Unit System efficiency • 98.0%'CEC, 98.6% Peak • 1000 V DC increases system efficiency • OpfiTrac Global Peak MPPT . Enhanced safety • Integrated DC AFCI • Floating system with all -pole sensitive ground fault protection • Reverse polarity indicator in combination with Connection Unit Future -proof • Complete grid management feature set • Integrated Speedwire, WebConnect, ModBus interface • Bi-directional Ethernet communications •Uiilityminteractive controls for active and • reactive power SUNNY TRIPOWER-12000TL-US / 15000TL-US 2000OTL-U5 / 24000TL-US / 30000TL-US - - • - `Y. The ultimote solution.for decentralized PV plants, now up to 30 kilowatts n ` Theworld's best-selling three-phase PV inverter, the SMA Sunny Tripower TL -US, is raising the bar for decentralized commercial } , ` PV systems. This three-phase, transformerless inverter is UL listed for up to 1000 V DC maximum system voltage and has a peak efficiency above 98 percent, while OptiTrac Global Peak minimizes the effects of shade for maximum energy production: . .PSE %N T;f f , *IM 0 SM The Sunny Tripowerdelivers a Future -proof solution with fullg rid management Functionality, cutting edge"communications and .advanced monitoring. The Sunny Tripower is also equipped with all -pole ground fault protection and iritegrdted AFCI for a safe,, ry reliable solution. It offers unmatched flexibility with a wide input voltage range and two independent MPP trackers. Suitable for both 600 V DC and 1,006V DC applications, the Sunny Tripower allows for flexible design and a lower levelized cost of energy. www:SMA-America.com Technical data - Connection Unit � 1♦� CU IOOo-US-10 Sunny Tripower Sunny Tripower Sunny Tripower Sunny Tripower Sunny Tripower I 12000TL-US 15000TL-US 2000OTL-US 24000TL-US 3000OTL-US Input (DC) I 96 I t Max. usable DC power (Q cos pal) 12250 W 15300 W 20400 W = =2A500 W r --30800 W Max. DC voltage ' 1000 V = 17-1000 V = I -1000 V ' 1000 V = --450V F--1000 V ,Rated MPPr voltalae range-----------Ir-300V. ..800 V 300 V...800 V 380 V...800 V r 800V 500V...800 V I• MPPToperating voltage range 150 V...1000 V 150 V...1000 V 150 V...1000 V 150 V...1000 V 150 V...1000 V Min. DC voltage /start voltage 150 V / 188 V _150 V / 188 V 150 V / 188 V 150 V./_188 V 150 V./ 188 V Number of MPP, tracker inputs 2 312 2 2 2 Max. inp t current /per MPP tracker.input 66 A / 33 A3 _66 A / 33 A 66 A Output (AC) _AC nominal power _ 12000 W = F--15000 W 20000 W 24000 W 30000 W = Max. AC apparent power 11 12000 VA 15000 VA 20000 VA 24000 V =30000YA= Output phases/line connections 3 / 3 -N -PE - 3 / 3 -N -PE, - 3 -PE Nominal AC voltage 480 / 277 V WYE 480% 277YWYE, �480_V-Delta AC voltage range _ _ ___ 244 V...305 V Rated AC grid Ire 1 60 Hz AC grid frequency /mange 50 Hz, 60 Hz / b Hz...+5 Hz __Max. output current _ X1'4.4 A� r 18�A 24 A F-29 �-Ate, 36.2 A Power factor at rated power / adjustible displacement 1 /_0.0 Ieadina...0.0 lagging Harmonics < 3% Efficiency, � Max. efficiency / CEC efficienty 1 98.2 % /_97.5 % 98.2 % /_97.5 % 98.5 % Protection devices e { DC reverse polariy protecfion=r F• • • • Ground fault monitoring_/ grid monitoring • • IF • • • All pole sensitive residual current rnoni1ori;q---q-nTt'= 1 • 1 • •711 • 11 • DC AFCI compliant to UL 1699B • 11 • •31 • • AC short circuil protection _ _ • 31 • 31 • 31 1• 31 • Protection class / overvoltage category - I / IV3 IV I /.IV3 General data Dimensions (W / H / D) in mm (in) 665 Packing dimensions (W /in mm (in) I / 790 /380 _ (30.7 /31.1 15.0) Weighs - 55 kg 1121,Ibs) _ _ _ Packing weight 61,kg' Operating temperature range 25°C...+60°C - Noise emission (typical) -/internal consumption at night 51-dB(A) / 1 W o • =T000loav Tronsformerless x Cooling concept /electronics protection rating OpfiCool /NEMA 3R - - Features Display_/LED indicators (Status / Faolt /Communication) - / • _ _ _ _ Interface: RS485 /-Speedwire, WebConnect O/• Data interface: SMA Modbus / Sunspec ModBus • /• e Af[PC<rsriPG Ev RS485 interface - Connection Unit � 1♦� CU IOOo-US-10 L""-_:,'SrSMA Cluster ControllerDM-485C&US-10 CLCON-10 " I L - J -__.__________--------------- . Efficiency cum SUNNY -----------i '---------- I ----------------------- I I I t I I I 96 I t I I�I 92 - w I �I Im W I I 90 -; ...... I V I TI LI I 5I 97 ..................._...........:......... BB I• 0.0 0.2 1 0.4 0.6 0.8 1.0 I i ------------------ I Output power/ Rated power ________________________I -. c E ..P r .5 B v as 0 2 ii e• 80 18 c9 o .� 8 J. 94 92 - w � �Y 90 -; ...... Em IVB -500 V)! 97 ..................._...........:......... BB Eta IV„ -720h - � 500 � B00 r e6 -•- Elaly„ -eoovl y c E ..P r .5 B v as 0 2 ii e• 80 18 c9 o .� 8 J. t 1� LLI"u "Top.Down" 'P --,,The' Original V'M66nting System for Ground Applications Benefits of GroundTrac@ Patent#6,360,491 • Industry's preferred low cost and easiest to install ground mount system - Used for kW to Multi MW projects • Patented ground mount system ships from av6ilable'stock • Proprietary Drop -N -Lock rail insert drops in and locks ProSolar GroundTrac@ rails in place • Over 10 years of ProSolar's proven design • Pre-engineered and tested for easy permitting • No cross -bracing required W low Q "Ir lit F. . See Below Distance depends I tilt42" angle isee angle chart) -- Assemble r4 usable grade stakes (ProSolar metal grade stake kit shown). Recommend 2"x 4" vertical support. Dig footings. - Use 1/2",drill ,bit and 9/16" socket to attach grade 1 i Lateral (left to right) footing spans stake'kit to 2" x 4". Attach 1" x 4" wooden horizontal listed on page4 (bottom). Front to support using 3-1/2" (min.) C -clamps. Grade stake kit rear footing spans listed in angle includes: 24" threaded metal stake, aluminum spacer charts on page 4 (top). Refer to block, bolt and washer. engineering reports for footing specs. C 4) Place horizontal: 1-1/2" schedule 40 galvanizea water pipe with slip-on vz Hollaender@ Tees. Adjust 0 -clamps as necessary to level pipe. \ ' �6 •,' I I I I I I I I I 2" I OMeasure vertical pipe lengths, allowing 2" (min.) from bottom of footing to avoid pipe contact with moisture. � F . Insert vertical pipes into tees and fasten lower tee set screw. Center pipes in • footings by sliding left or right. Pour or pump mixed concrete into footings. t'7LA — ,"'+_ t, -...._.... -{�.w•.....�.c',-, s•r-..,�. .-•_-'�-'�!'�'.. :.."�..xw:.cr+.�.r"•. " --'Rest rail on top of horizontal pipes. Run string level on top or bottom to align tops of support rails. - .X ,�,-• -�- - -~ _ Fasten. rail, inplace by'using GroundTrac@ drill -guide -----}--``T '—'alb—ng alon to' and bottom of horizontal g p pipes. Drill •U -bolt locking hole!;'�in,place. Leave at least one drill T guide attached after\drilling to keep rail in place. GroundTrac® Drill.Guide' Base and Drill Bit. Install at least one rail every 10' for proper pipe spacing. . B Insert U -bolt into locking rail holes and place 0OptionalSnow Drop -N -Lock insert'into the rail. Remove l.oadEnhancer remaining drill guide'arfdNproceed with other rails. t - Remove grade stakes. _Tighten all tee set screws,' fo.,17 ft -lbs witl`torque " wrench. Install remaining ' rails; evenly tightening U -bolt nuts. A. .. XPI .'-Pre-assemble clamping �:.. hardware and install solar EZ•rail" ! modules and EZ rail endcap5. ` en Install Install 1-1/2" plastic pipe endcaps for schedule 40 pipe - as necessary. . ICompleted installation. • 9 0 ��� s., .. -.Y •" r�+_- �. _:x�.�z..�,+i:�-•� �fi ,. ; 3 -. _ , '--'—`!' Front 5:.,, to Rear, 124n and 136.. Rall 124" x 2-1/2" Support Rail 1! Array Footing Angle Chart Supports up to (3) 39.5' Wide Modules Angle Distance 0° 84" 124" = - 84" amu-• . ..' i+ . �.. 136" x 2-1/2" Support Rail, " "~• Supports up to (4) 32.5" Wide Modules �5 1 ............... 73" I--------------- 76" I-------- 79" ------j j�jl 30" Max I. 60" Max from top 1-------- 81"-------iil from top of footing I-------------- 83" ----•----------I0 of footing --------------- 84" - - ------------ '! 1- -------------- 84" --------------- 4 n1l" 124" and 136" Rail r!"I" i `3 ' Front to Rear 136" 124" x 2-1/2" 5o 84" �-„ Arra Y Footing (3) 39.5" wide modules 2-1/2" (4) 39.5" wide modules Angle Distance 15° 81" T - 00 20° 79" 84" Front to back footing spacing See Angle Chart 250 76" 108" Pre -slotted rails at: 84" on Center 30°' 73/$A' �`+ed 106" 164" x 3" Support Rail 150 104" �5 1 ............... 73" I--------------- 76" I-------- 79" ------j j�jl 30" Max I. 60" Max from top 1-------- 81"-------iil from top of footing I-------------- 83" ----•----------I0 of footing --------------- 84" - - ------------ '! 1- -------------- 84" --------------- 4 n1l" 124" and 136" Rail r!"I" i `3 ' Front to Rear 136" 124" x 2-1/2" �' r, �-„ Arra Y Footing (3) 39.5" wide modules 2-1/2" (4) 39.5" wide modules Angle Distance Y. T Lateral (left to right) footing span (max) 30 Ib/ft2 snowload 00 108" 84" Front to back footing spacing See Angle Chart 50 108" Pre -slotted rails at: 84" on Center 84" on Center 10° 106" 164" x 3" Support Rail 150 104" Supports up to (4) 39.5" Wide Modules 200 101" 39.5" - .164'- _ -• i� 3" - y� � R 108' r { r Refer to engineering report for footing specs N 164" Rail Angle Chart ed / - - 101" - - 104" - - 106" - - 108" _.: 108" 164" Rail Refer to engineering report for footing specs GroundTrac@ Rail Sizes 124" x 2-1/2" 136" x 2-1/2" 164" x 3" Number of Modules (3) 39.5" wide modules (4) 32.5" wide modules (4) 39.5" wide modules Lateral (left to right) footing span (max) non -snow load 10' 10' 8' Lateral (left to right) footing span (max) 30 Ib/ft2 snowload 6' 6' Not snowload rated Front to back footing spacing See Angle Chart See Angle Chart See Angle Chart Pre -slotted rails at: 84" on Center 84" on Center 108" on Center .now ....._Y: wu.urae „„ n ClCltrll Professional Solar Products (ProSolar) • 1551 S. Rose Ave., Oxnard, CA 93033 805-486-4700 • www.prosolae.com @Professional Solar Products, Inc March 2011. GroundTrac@ is a registered trademark and covered under pat.#6,360,491 • professional SOLAR products,- l \I i No buss bar Green lock washer indicates electrical bond Assembled Self -bonding Mid Clamp With SS Bus Bar Self -bonding Mid Clamp Fastened on Rail (solar module not shown) II ProSolar® RoofTrac® . Bonding and Grounding Guide (Patent Pending) Applies to GroundTrac® and SolarWedge® mounting systems which utilize the RoofTrac® raiVclamp design. For RoofTrac® Rail Bonding Splice • Drill 1/2" holes at bottom of rails with 1/2" °10 Irwin Unibit® using the rail support as a hole location guide. • Insert 5/16" bolt through support holes and hand thread into thread rail splice insert. Fasten to 15 ftdbs: For Bonding Module Frame and Clamps to Support Rail • Fasten pre -assembled mid -clamp assembly to module frame, to 15 ft -lbs. Module Frame Design: double wall, aluminum, 1.2"-2:0" tall, 0:059"-0.250" thickness, UL1703 or equivalent tested module. UL467 standard tested bonding equipment for use with Professional Solar Products (ProSolar®) support rail. Bonding of module to RoofTra& rail via ProSolar® rail channel nut using buss bar. Bonding of RoofTra& rail to RoofTrac® rail via ProSolar® UL467 tested universal splice kit (splice insert and splice support). Grounding of RoofTra& rail via Ilsco SGB4 rail lug. System to be grounded per National Electrical Code (NEC). See NEC and/or Authority Having Jurisdiction (AHJ) for grounding requirements prior to installation. See final run (racking to ground electrode) grounding equipment installation instructions for specific installation information. COPYRIGHT PROFESSIONAL SOLAR PRODUCTS 2015: All information contained in this manual is property of Professional Solar Products (PSP). TileTra& is a registered trademark for PSP and is covered under U.S. patent #5,746,029. RoofTm& and FastJack® are registered trademarks for PSP and are covered under U.S. patent #6,360,491. RoofTra& bonding designs patent pending. ProSolar® UL2703 Bonding and Class A Fire Rating Page 1 of 4 professional SOLAR ProSolar® RoofTraco. . products.r Bonding and Grounding Guide (Patent Pending) • Can be placed under module to - hide -connection if desired Basic Wiring Diagram i I m rounding Connection :O SGB -4 rail ground connection Grounding Lug Grounding Lug COPYRIGHT PROFESSIONAL SOLAR PRODUCTS 2015: All information contained in this manual is property of Professional Solar Products (PSP). TileTra& is a registered trademark for PSP and.is covered under U.S. patent #5,746,029. RoofTra& and FastJack® are registered trademarks for PSP and are covered under U.S. patent #6,360,491. RoofTra& bonding designs patent pending. ProSolar® UI -2703 Bonding and Class A Fire Rating Page 2 of 4 . • Intertek Listing Constructional Data .Report (CDR) 1.0 Reference and Address Report Number io0779407LAX-003 Ori inal Issued: 14 -Sep -2012 Revised: 28-Apr-2015- 8-A r-2015Standard(s) L Subject 2703 - Outline of Investigation Rack Mounting Systems and Clamping Devices for Standard(s) Vat -Plate Photovoltaic Modules and Panels. Issue #2: 2012/11/13 ` Applicant Professional Solar Products, Inc. Manufacturer Professional Solar Products; Inc. . 1551 S. Rose Avenue Address Oxnard, CA 93033 Address 1551 S. Rose Avenue Oxnard, CA 93033 Country USA Country USA Contact Stan Ullman Contact Stan Ullman Phone (805) 486-4700. Phone --------------- (805) 486-4700 FAX (805) 486-4799. FAX (805) 486-4799 Email s(cDprosolar.com Email s@prosolar.com ^ A s .1 i -t: Page 1 of 63 4 This report is for, the exclusive use'of, lntertek's'client and, Is provided pursuant ;to the agreement 'between iritertek and its client''Iniehdk's'responsibility'ahC liability, are limited; ,to the terms and c'ond"honspf the agreement. Intertek''assumes'no'H bility,totany, partyr other: than. to the, Ckeht "n accordance: ninth the agreement foi any expense or damage :occasioned by the use of this report..Oniythe Client �s authorized to, permit, copyingoi-distnliution of -this report and then orily in 6 entiretyAny=use ofthe'Iniertek hame.or one of its marks.foi ttie sale'or_adveAisement of the tested rriaterial„proJuct.or service,rnustfirst be approieH m writing by IntekeR The observations:and test results in thi's repoit,a're relevant only;to the sample;tested.,This re'port,by itself -does notimprythat'thd • material, product; or service a of has ever been undeP-an Infertek certifi_catiori ProSolar® UL2703 Bonding and Class A Fire Rating Page '3 of 4 i Report No. {100779407LAX-003 Page 2 of 63 , Professional Solar Products, Inc. " Issued: 14 -Sep -2012 Revised: 28 -Apr -2015 2.0 Product Description Product Photovoltaic Racking System - Brand name ProSolar The product covered by this listing report is a rack mounting system. It is designed to be - installed cin a roof. It will be secured by means of Fast Jack, or TileTrac attachments, ; depending on the type of roof it is intended to be installed upon. The Rooftrac mounting system is comprised of support rails and top-down clamping hardware -This device can be used•on most standard construction residential roof -tops. , This system is in compliance with the mounting, bonding and grounding portions of UL Subject 2703. This system has the following fire class resistance_ratings: Class A for Steep Slope Applications when using Type 1 or Type 2, Listed Photovoltaic Modules. Class A for Steep Slope Applications when using Type 2, Listed Photovoltaic Modules with or without the wind skirt. -Class A for Low Slope Applications when using Type 1, Listed' Photovoltaic Modules when a minimum of 12" gap between the roof surface and the bottom of the module is maintained. Class A for Low Slope Applications when using Type 2, Listed Photovoltaic Modules when a minimum of 14" gap between the roof surface and the bottom of the module is maintained. i RoofTrac has different types of bonding and grounding, below is a list of them: - Bonding of module -to -Roof Trac rail via Weeb PMC , Description Bonding of module-to-RoofTrac rail via ProSolar rail channel nut using buss bars Bonding of module -to -Roof Trac rail via Ilsco SGB -4 lugs . Bonding of Roof Trac rail -to -Roof Trac rail via Weeb Bonding Jumper -6.7 Bonding of Roof Trac rail -to -Roof Trac rail via llsco SGB -4 Lugs. Bonding of RoofTrac rail-to-RoofTrac rail via ProSolar UL 467 tested universal splice kit (Splice Insert and Splice Support) Issuance of this report is based on testing to PV module frames with a height of 1 1/4 inch to 2 inches t The grounding of therentire system is intended to be in accordance with the latest edition of the National Electrical Code, including NEC 250: Grounding and Bonding, and NEC 690: Solar Photovoltaic Systems. Any local electrical codes must be adhered in addition to the national electrical codes. - This product investigation was. performed only with respect to specific properties, a limited range of hazards, or suitability for use under limited or special conditions. The following risks and other properties of this product have not been evaluated: electric shock, Ultraviolet light exposure. _ Models RoofTrac . Model Similarity N/A Fuse rating: 20 A , Mechanical Load: 30 PSF Fire Class Resistance Rating: Ratings Class A for Steep Slope -Applications when using Type 1 and Type 2, Listed Photovoltaic Modules. ' Class A for Low Slope Applications when using Type 1 and Type 2, Listed Photovoltaic Modules Mechanical load was tested using 60 Cell Canadian Solar Modules model CS6P with 40mm frame height and maximum span of.48 inches using 4 inch and 6 inch TileTrac or FastJack Other Ratings posts with 1-1/2 inch tall RoofTrac rail. And maximum span of 72 inches using 4 inch and r6 inch TileTrac or FastJack with 2-1/2 inch tall RoofTrac rail. ProSolar® UL2703 Bonding and Class A Fire Rating Page 4 of 4 ED 16.3.15 (1 -Jan -13) Mandatory r� U v The WEEB Lug consists of a WEEB (Washer, Electrical Equipment Bond), lay -in lug, and hardware. It is used with one solid or stranded copper wire (6AWG to 14AWG), or two copper wires (10AWG to 12AWG) to provide a continuous ground on roof or ground mounted solar systems. Unlike traditional lay -in lugs, the WEEB Lug does not require surface preparation on rail or module to install. The WEEB Lug. is ,installed using a 1/4-20 stainless steel screw which tightens the WEEB, allowing the specialized teeth to , embed into anodized aluminum, galvanized steel, or any electrically conductive metal to establish a gas tight electrical connection. The tin-plated Lug assures minimum contact resistance and protection against corrosion. The copper wire is clamped by a 1/4-28 stainless steel screw, which is horizontal to the tang for easy access when mounted under a PV module. The low profile of the WEEB Lug allows it to be installed in a variety of positions and comes with hardware to mount it to a rail or through a 1/4 inch clearance hole. ' Material: 304 stainless steel, tin-plated copper, outdoor rated • Low profile design Multiple. equipment groundconductor allowance: One 14 AWG to 6 AWG or two 10 AWG, two 12 AWG • Listed to ANSI/UL 467 by Intertek ETL .Contact us at: 845.247.4708 www.we-lic.com r ' VINC1 & AS.SOCIATES 61ruc.&ra/ 6nyineers August 16, 2017 t Chico Electric 36 W. Eaton Road Chico, CA 9597.3 Subject: Review of minimum footing requirements Project 228 Module Photovoltaic Groundmount Installation7 Arra s � y) Violich Farms.lnc Stanford Ranch; Durham, CA 95938. V&A Project: No. 12-3457 ' Theur ose of this report is t vi p p p opro de a site specific analysis of the minimum footing requirements for the photovoltaic array. groundtrac installation at Stanford Ranch in Durham, CA 95938. Based upon; our review of the 7 Photovoltaic Arrays, installed 4 modules high and .9: modules wide. The PV Array shall have a transverse spacing of approximately 5.58 feet • on center and a longitudinal spacing of 8.12 feet maximum. Based upon.a.wind speed of 100 mph: Exposure C, it was determined that the minimum required footing depth. is. 30 inches minimum below grade for the front footing and .36 inches minimum below grade for the rear footing for a 12 inch diameter pier footing. The footing sizes are ' based upon:the worst: case loading due to horizontal 'and vertical wind loading. Refer to attached calculations and details for additional information. Our professional services have been performed using the degree of care and skill ordinarily exercised under similar circumstances by reputable engineers practicing in this locality. No ' other warranty; expressed or implied, is made as to the professional options included in this report. We hope this pro des you with the information you need at this time. Please call us if you have any st, r arding this report. P� FESS Sincerely,SR�cwtRo` VINC1- A IATES No. S4411 Z Oc Exp. .12/31/17 Ja, es R inl/CTIfRa� ci, S.E. .: gTFOF CASYF�� E. i $e No. S=4411 .,175 E. WILBUR ROAD, STE 103 .THOUSAND OAKS, CA 91360 p'805.496-2100 :f 805.496-2442 e'vinci&incise.com DATE: 8/16/2017 VINCI ASSOCIATES SHEET.' Al c. PROJECT: Violich Farms Inc c3frucfura/ Cngineers JOB NO.: _ 12-3457 ' Stanford Ranch 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.: JRV Durham, CA 95938 p805.496.2100 . t8o5.496.2442 • evinci@VinciSE.com ENT: —Ch Electric ' DESIGN DATA: WIND DESIGN CRITERIA: ' BASIC WIND SPEED = 100. mph (ASCE 7-10: Risk Category 1 per, Table 1.5-1 & Figure 26.5-1C) ' WIND EXPOSURE = C GROUND SNOW LOAD = 0 psf SOLAR MODULE ARRAY DATA t Sloped Dimension of Array = 164 in ` ` Angle of Array = 30 degrees Slope of Array: = 6.00 :12 ' No. of Modules in Transverse Direction = 4 No. of Modules in Longitudinal Direction = 9 ' Total No. of Modules in Project =• 228 je Transverse Post Spacing = 5.58 ft `. rLongitudinal Post Spacing = 8.12 ft Number of supports - Transverse Direction = 2 ' Diameter of Pier Footing = 12 in Number of Arrays = 7 ' Array Uniform Load = 2.8 psf ' SOIL DESIGN CRITERIA (Based upon Chapter 18 of CBC) Allowable Soil Bearing Pressure = 1500 psf ' Allowable Soil Lateral Bearing = 200 pcf Allowable Shaft Skin Friction / Cohesion = 130 pcf 1 I Y ' r f CASE CNW CNL C•NW CNL CNW CNL CNW CNL A PROJECT: vouch Farms Inc �;. a PAGE A2 AA�» r CLIENT: StanfordRanchrDurham,CA959'38""E DESIGN BY: 1RU JOB NO.: 15.3457 DATE : OS/i6/17 REVIEW BY Wind':AnaV4L, forr Open Structure`;(S,ola_rrPanels)_Basec! ASCEy7-2010, 'i ; r l +20.13 INPUT DATA ` Exposure category (13, C or D) = C Importance factor, 1.0 only, (Table 1.5-2) I,,+, = 1.00 Basic wind speed (ASCE 7-10 26.5.1) V = 1.00 mph Topographic factor (26.8 & Table 26.8-1) Kn = . `-1 0` Flat se Height of mean roof h = ."f 5, ft 2 Roof slope , t .0(1,` 12 ' Roof length L = 1b r« : ft Roof horzontal projected width B = 10 ft z Effective area of component / cladding A = 10 ft - 8• DESIGN SUMMARY 1. Main Wind -Force Resisting System Max horizontal force / base shear from roof = 1.52 kips ' + .°.,x!;,,'0.15 kips (eave &columns increasing) E 1.68 kips A Max vertical download force = 3.05 kips Max vertical uplift force = 2.65 kips Max moment at centroid of base from roof = 10.65 ft -kips r �. + 1:07, ft -kips (eave & columns increasing) S r E 11.72 ft -kips :'- 2. Component and Cladding Elements t , Max inward pressure = 75 psf p + Max net outward pressure = . 74 psf + ' ANALYSIS 1 ` Velocity pressure , qh = 0.00256 Kh Ke Kd VZ ' 18.50 psf ` where: qh = velocity pressure at mean roof height, h. (Eq. 28.3-1 page 298 & Eq. 30.3-1 page 316) t Kh = velocity pressure exposure coefficient evaluated at height, h, (Tab. 28.3-1, pg 299) = 0.85 , - Kd = wind directionality factor. (Tab. 26.6-1, for building, page 250) 4, i = 0.85 h = height of mean roof = 5.00 ' ft i r` T Main Wind -Force Resisting System (Sec. 27.4.3) p = gh G CN ,1+� F=pAf , where: G = gust effect factor. (Sec. 26.9) _ 0.W 0 = roof angle = 26.57 degree k F < 45 deg. (Satisfactory] • Af = roof actual area. = 55.9 ftZ, windward = 55.9 ft 2, leeward CN = net force coefficients. (Fig. 27.4-4,. page 267) Check Fig. 27.4-4 limitation h / B = 0.50 within [0.25 , 1.01 [Satisfactory] 0 Y WIND TO BOTTOM, 7 = 0° WIND TO TOP, = 180° CLEAR FLOW OBSTRUCTED CLEAR FLOW OBSTRUCTED CASE CNW CNL C•NW CNL CNW CNL CNW CNL A -1.66 -1.71 --1.50 •-1.75 1.92 1.96 = 0.55 -1.00 s -26.14 -26.86 -23.58 -27.58 30.14 30.86 8.71 -15.72 26.57 F ki s -1.46 -1.50 -1.32 -1.54 1.68 1.72 .0.49 -0.88 B -2.45 -0.41 -2.30 -1.01 2.42 0.86 1.46 0.05 r s -38.58 1 -6.42 . -36.16 -15.85 38.00 13.56 22.99 0.85 F (kips) -2.16 1 -0.36 -2.02 -0.89 2.12 0.76 1.29 ' 0.05 r � • r U DATE: 8/16/2017 PROJECT: Violich Farms Inc Stanford Ranch Durham, CA 95938 CLIENT: Gnico tlectric VINCI & ASSOCIATES SHEET: A3 . c5lmclural 6ngmeers JOB NO.: 09-3457 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.: ,1RV p 805.496.2100 • 1805.496.2442 • e vinci@YnciSE.com FOOTING DESIGN - PV Sloped Dimension: 164 in ' TYPICAL YARRAY , PV Array Angle: 30 degrees Post Spacing: 8.12 ft No. of Supports: 2 Footing Diameter (d): 12 in MAXIMUM VERTICAL FORCE: 3.05 k / (10.0 x 10.0) = 30.50 psf "x 0.6 = 18.30 psf MAXIMUM UPLIFT FORCE: 2.65 k / (10.0 x 10.0) = 26.50 psf x 0.6 = 15.90 psf ASD Factor GROUNDTRAC SYSTEM CAST INTO EARTH Maximum Vertical Load: (Worst Case: DL+ Wind) P= 18.30 psf + 2.8 psf DL + 0 psf snow = 21.10 psf P = 21.10 psf x ( 142 " /12"/ft) x ( 97.4 " /12"/ft) = 2028 lbs for 2 Supports P = 1014 lbs/footing Try 12" diameter footing Soil Bearing = 1014 / (p x 0.50) = 1291.4 psf << 1995 psf 1500 psf x 1.33 (CBC Table 1806.2) Maximum Uplift Load: Therefore O.K. P = 15.90 psf - 2.8 psf DL = 13.10 psf. P = 13.1 psf x ( 142 " /12"/ft) x ( 97.4 " /12"/ft) = 1259 lbs for 2 Supports P = 629 lbs/footing Try 12" diameter x 30 " footing Allowable uplift = Concrete DL + Soil Cohesion ( 130 psf x 1.33 ) per CBC Table 1806.2 [ (n x (d/2)Z) x 150 pcf x 2.5 ft ] + [ (7r x d) x 2.54 ft x 172.9 psf] = 1678 lbs Design Ratio = ( 1,678 lbs / 629 lbs ) = 2.7 Therefore O.K.' DATE:8/16/2017 VINCI & ASSOCIATES SHEET: A4 ' r PROJECT: Violich Farms Inc c5lruclural (inyineers JOB No.: 09-3457 Stanford Ranch 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.: JRV ' Durham, CA 95938 p 605.496.2100 • f 605.496.2442 - e vinci@VinciSE.com CLIENT: Chico Electric • DESIGN OF PIER FOOTING & POST CHECK IWOONT POSTAWIND Post Spacing: 8.12 ft t Number of Columns: 2 Horizontals Load: 10.1 psf Exposed wind surface 3 ft ' -DESIGN BASED UPON NON -CONSTRAINED CBC FORMULA: (CBC Section 1807.3.2.1) ' d = (A/2) (1 + ( 1 + (4.36h/A) )^.5)) A = (2.34 * P) / (S1 * b) P ' P = 102 lbs = 10.1 psf x 8.1 ft x 3 ft / 2 columns h = 3.08 ft (Average Height) ' S1 = 266 psf/ft x (d/3) (includes 1.33 increase for wind) h b = 12 in (diameter or diagonal of square) d GOVERNS >>> Try d = (ft) S1.@ (113)d (PSQ A Calc d (ft) . 1.54 141 1.639 3.30 1.79 164 1.410 2.99 2.04 187 1.238 2.75 2.29 210 1.102 2.55 2:5'4. 233 0.994' 2.39 2.79 256 0.905 2.25 DESIGN COLUMN Mcoi = Ph = 315 ft -lbs Scoi = Mcd / Fb = 0.16 in Fb = 0.66 x 35,000 psi ' ASTM A53, Gr B »»> USE: 1-1/2" Schedule 40 Pipe S = 0.31 in' ' with 12 inch diameter x 30 inch MIN. deep concrete footing. 1 DATE: 8/16/2017 VINCI & ASSOCIATES* SHEET: A5 PROJECT: Violich Farms Inc 61ruclura/ Cnymeers JOB NO.: 09-3457 1 Stanford Ranch 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.: JRV Durham, CA 95938 p805.496.21100 • f805.496.2442 - evinci@VinciSE.com LIENT: Chico Electric 1 DESIGN OF PIER FOOTING & POST CHECK REAR POST 1 Post Spacing: 8.12 ft Number of Columns: 2 Horizontal Load: 10.1 psf 1 Exposed wind surface 3 ft -DESIGN BASED UPON NON -CONSTRAINED CBC FORMULA: 1 (CBC Section 1807.3.2.1) d = (A/2) (1 + ( 1 + (4.36h/A) )^.5)) A = (2.34 P) / (S1 ' b) P P P = 102 lbs ,= 10.1 psf x 8.1 ft x 3 ft / 2 columns, ' h = 6.28 ft (Max Height) 1 S1 = 266 psf/ft x (d/3) - (includes 1.33 increase for wind) h b = 12 in (diameter or diagonal of square) 1 1 d 1 1 GOVERNS >>> Try d = (ft) S1 @ (113)d (Psf) A Calc d (ft) 2 183 1.262 3.64 2.25 206 1.122 3.39 2.5 229 1.010 3.18 2.75 252 0.918 3.01 3 275 Q.842 2.86 3.25 298 0.777 2.73 1 DESIGN COLUMN ' MC0I = Ph = 641 ft -lbs ' S.a = M.i / Fb = 0.33 ' in Fb = 0.66 x 35,000 psi ASTM A53, Gr B 1 »»> USE: 1-1/2" Schedule 40 Pipe S = 0.31 in with 12 inch diameter x 36 inch MIN. deep concrete footing. 1 � T U.S. DEPARTMENT OF HOMELAND SECURITY OMB No. 1660-0008 Federal Emergency Management Agency Expiration Date: November 30, 2018 National Flood Insurance Program ELEVATION CERTIFICATE Important: Follow the instructions on pages 1-9. Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/comr)anv. and (3) buildina owner. SECTION A — PROPERTY INFORMATION FOR INSURANCE COMPANY USE Al. Building Owner's Name Policy Number: BUD KEENEY A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Company NAIC Number: Box No. 2243 DURHAM DAYTON HWY City State ZIP Code DURHAM California 95938 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) AP# 040-200-083 A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) SOLAR A5. Latitude/Longitude: Lat. 39*38'32.0" Long. 121*47'29.2" Horizontal Datum: ❑ NAD 1927 ❑x NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. AT Building Diagram Number A8. For a building with a crawlspace or enclosure(s): a) Square footage of crawlspace or enclosure(s) sq ft b) Number of permanent flood openings in the crawlspace or enclosure(s) within 1.0 foot above adjacent grade c) Total net area of flood openings in Aft sq in PERMIT #—I� Z— . -- d) Engineered flood openings? ❑ Yes ❑ No BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR CODE COMPLIANCE A9. For a building with an attached garage: DATE Z BY a) Square footage of attached garage sq ft b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade c) Total net area of flood openings in A9.b sq in d) Engineered flood openings? ❑ Yes ❑ No SECTION B — FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number B2. County Name B3. State 060017 BUTTE California 84. Map/Panel B5. Suffix B6. FIRM Index B7. FIRM Panel B8. Flood Zone(s) B9. Base Flood Elevation(s) Number Date Effective/ (Zone AO, use Base Revised Date Flood Depth) 06007CO520E E 01/06/2011 01/06/2011 AO/AE 159 B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9: ❑ FIS Profile ❑x FIRM ❑ Community Determined ❑ Other/Source: B11. Indicate elevation datum used for BFE in Item 69: ❑ NGVD 1929 ❑x NAVD 1988 ❑ Other/Source: B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes ❑x No Designation Date: ❑CBRS ❑ OPA " Bl 7-2092 FILE/PCI _. . 040-200-083,-- 1 FEMA Form 086-0-33 (7/15) Replaces all previous editions. I SEPT 7, 2017x—,%, z ot6 GRND MNT SOLAR COM V J L ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 2243 DURHAM DAYTON HWY City State ZIP Code Company NAIC Number DURHAM. California 95938 SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) C1. Building elevations are based on: ❑x Construction Drawings* ❑ Building Under Construction* ❑ Finished Construction *A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations - Zones Al -A30, AE, AH, A (with BFE), VE, V1 -V30, V (with BFE), AR, AR/A, AR/AE, AR/A1-A30, AR/AH, AR/AO. Complete Items C2.a-h below according to the building diagram specified in Item A7. In Puerto Rico only, enter meters. Benchmark Utilized: BC 1255 Vertical Datum: NAVD 1988 Indicate elevation datum used for the elevations in items a) through h) below. ❑ NGVD 1929 0 NAVD 1988 ❑ Other/Source: Datum used for building elevations must be the same as that used for the BFE. Check the measurement used. a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 0 feet ❑ meters b) Top of the next higher.floor x❑ feet ❑ meters c) Bottom of the lowest horizontal structural member (V Zones only) 0 feet ❑ meters d) Attached garage (top of slab) ❑x feet ❑ meters e) Lowest elevation of machinery or equipment servicing the building 160 0 ❑x feet ❑ meters (Describe type of equipment and location in Comments) f) Lowest adjacent (finished) grade next to building (LAG) 158 5 ❑x feet ❑ meters g) Highest adjacent (finished) grade next to building (HAG) 158 9 ❑x feet ❑ meters h) Lowest adjacent grade at lowest elevation of deck or stairs, including ❑x feet ❑ meters structural support SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. l certify that the information on this Certificate represents my best efforts to interpret the data available. / understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. Were latitude and longitude in Section A provided by a licensed land surveyor? ❑x Yes ❑ No ❑ Check here if attachments. Certifier's Name License Number JOSEPH F DOMINICK, III LS 51101 _AND SSR 5 F 00M L� Title SURVEYOR O p Place Company Name DOMINICK'S - CIVIL ENGINEERING AND SURVEYING Seal — 11�1E� 10 Address PO BOX 1216 - 406 PINE STREETcP Q Tq��c ,-�a��FO��\ City State ZIP Code RED BLUFF California 96080 -M Signature Date Telephone 08/16/2017 (530) 529-3560 ,G Copy all pages o this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner. Comme'lits (including type of equipment and location, per C2(e), if applicable) FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 2 of 6 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 2243 DURHAM DAYTON HWY City State ZIP Code Company NAIC Number DURHAM California 95938 SECTION E — BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), complete Items E1—E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B,and C. For Items E1—E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. E1. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. b) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the LAG. ' E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or 9 (see pages 1-2 of Instructions), the next higher floor (elevation C2.b in the diagrams) of the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E3. Attached garage (top of slab) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E4. Top of platform of machinery and/or equipment servicing the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G. SECTION F — PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA -issued or community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner or Owner's Authorized Representative's Name JOSEPH F DOMINICK, III Address City State ZIP Code PO BOX 1216 RED BLUFF California 96080 Signature---- Date Telephone r _ 08/16/2017 (530) 529-3560 Comments° Com" ❑ Check here if attachments. FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 3 of 6 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 2243 DURHAM DAYTON:HWY City State ZIP Code Company NAIC Number DURHAM California 95938 SECTION G — COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8—G10. In Puerto Rico only, enter meters. G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2 ❑ A community official completed Section E for a building located in Zone A (without a FEMA -issued or community -issued BOE) or Zone AO. G3. ❑ The following information (Items G4—G10) is provided for community floodplain management purposes. G4. Permit Number G5. Date Permit Issued G6. Date Certificate of Compliance/Occupancy Issued G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement G8. Elevation of as -built lowest floor (including basement) of the building: ❑ feet ❑ meters Datum G9. BFE or (in Zone AO) depth of flooding at the building site: ❑ feet ❑ meters Datum G10. Community's design flood elevation: ❑ feet ❑ meters Datum Local Official's Name Title Community Name Telephone R Signature Date Comments (including type of equipment and location; per C2(e), if applicable) ❑ Check here if attachments. FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 4 of 6 Sign !n I by...y NISi I wick 0.rdl :r ((.._........... _..._..._.__... ----—......._...._.......... Enter keyword or item k ! INDUSTRIES HOME PRODUCTS RESOURCES ABOUT NSi CONTACT US CROSS-REFERENCE . SALES REP LOCATOR Home i Products ! Connector Bloks"' and Terminal Bloks"° ( Single, Primary, and Multiple Connector Blocks / Connector Blok Large Connector Blok Large Mouse over image for enlarged view Zoom Product information Documents Part ii AL -P2 -P2 (2) 350 MCM - 6 A1ArG Primary (2) 350 MCM - 6 AWG Secondary, Power DiSTRibution Block In Stock BliiiE COUIY7.i° BUILDING pl1/ISION AP OVEM Lj Type: ............................ _............ ...y...................................... ................„......................... Splicer/Reducer ...._...._..................... _._.... .......................................................................................... _.......................... :..._............ _..__ .................... ..................... • .. .. Wire Size: (2) 350 MCM-6 AWG(Line) - (2) 350 MCM-6 AWG(Load) Amperage Rating: 620 Amps Per Pole . ......... _..r. ............ ............ .............................. ..... ... _...........,-..._.... _..._.. Size: L=5.50 - H=3.25 - W=2.90 Voltage Rating: 600 V Application:. _ Terminate, Splice, Tap Power Connectors Color: - -... ....... ........... -........._.......__.__.._........ ( Black ..................................... ......................_........... ...-........... ........ ........ .... ,__.._. ......... _..._-... ..............._....._........-..._....._..._._.......... ........ ... .... ,....._._.-_.,..._..._..... Material: .... ..............-_._.... __...... Aluminum body -Glass Filled Polyester Base Mounting: ....................... ................... ............_...................... -........ _.........._....... _............._.......................... 2 Mounting Holes _................................................................................................................ -............... ............................... _..._.._.... _......... ............... .......................................... :................................... ................... Number Ot Terminals: ............... ............... ,..........._............. ............... .................. .... 14 ..... __....... .......__.._.......................... Standard:?Recognized _................. ............. ........ .................. .................. ..:..................................................... ...I ...................... ......... .._...... _.._................... ........... . to UL1059 Related Products • Connector BloksTM Drawn -SD F I „`,�i�• I Approved -KM -YI - p j i Z_?D i Title - Connector Bloks'" E -1 ....... _.... � ►I Fn--s--F' INDUSTRI123 Dual Rated Connector Bloks Insulator A B C D E F G H I. J Cat. No S 1.04 2.34 2.90 2.25 0.18 0.35 0.20 0.46 0.1 90.63 1.25 M 1.71 2.62 4.00 3.50 0.25 0.37 0.20 0.79 0.20 1.25 1.87 L 2.90 3.25 5.50 1 5.00 0.25 0.50 0.27 1.36 0.29 1 2.25 3.25 Insulator Block Part Temp . Line Side Load Side Amps Per L W H Insulator Block Size Number Rating Pole AS-11-11 90 C. It I I' 1 115 2.90 1.04 2.34 S 2-14 AWG 1 2-14 AWG AS-K1-K1 90 C U (!2) 175 2.90. 1.04 2.34 S 2/0-14 AWG 2/0-14 AWG AM-N1-N1 90C I(t 310 4.00 1.71 2.62 M 250MCM-6AWG 250MCW6AWG AM•P1-Pt 90 C I( ( 350 4.00 1.71 2.62 M 350MCM-6AWG 350MCM-6AWG AM-R1-R1 90 C , 380 4.00 1.71 2.62 M 500MCM.4AWG SOOMCM-4AWG j AS-K2-K2 90 C �1 i 350 2.90 1.04 2.34 S 2/0.14AWG 2/014 AWG AL-P2-P2 90C �" � 620 5.50 2.90 3.25 L 350MCM-6AWG 350MCtvLBAWG AL-R2-R2 90 CT�j Ir! 1 760 5.50 2.90 3.25 L 5OOMCM4AWG 5 ' NF Panelboards — Ready to Install (RTI) 20" Wide Enclosures -600Y/347 Vac Max. NF Main Lug Interiors Use 1-LINE6 Panelboards on 600 V 303W systems Single Phase 3 -Wire — Available Factory Assembled Only Three Phase 4 -Wire 1. "C' suffix indicates Copper bussing. 2. Type 1 enclosure catalogue numbers consist of MH plus the box height (example: MH44). Type 3R enclosure catalogue numbers add VJP to the Type 1 catalogue number (example: MH44VJP). . 3. Trim catalogue numbers consist of "NC" plus the box height plus "S" for surface trim or' F' for Bush Gm (example: NC44S). Trims for 400A and 60DA panels are vented and require a "V' after the height in the catalogue number (example: NC62VS). Add "HR" suffix to part number for hinged trims. 4. The maximum total amperage of two branch breakers mounted across from each other is 170A. 5. Embossed mounting holes add a 0.25 inch standoff to back of MH box. 6. End osures types 4 and 4X stainless steel are available factory assembled only. 7. Equipment ground bars must be ordered separately. 8. Additional panelboards with various maximum circuit numbers are available as Factory -assembled. Please contact your Schneider Electric Sales professional for details. F � 400A, 42 circuits Main lug interior with deadfront 400A interior Main lugs close-up DE5-12 Schneider 06112 QEleccrlc Enclosure Interior only Type 1 Type 3R, 12 Mains Rating (order branch (Amps) Max No. of Circuits circuit breakers Height Box Mono Flat Front Enclosure & Trim (4) separately) (In) 20" W x 5.75" D (F) flush (S) surface 20" W x 6.5" D (3) Catalogue No. Catalogue No. Catalogue No. Catalogue No. 18 NF4181-1 MH26 NC26() MH26WP 26 18 NF418LIC MH26 NC26() MH26WP 26 125 30 NF430L1 MH32 NC32() MH32WP 32 30 NF4306C MH32 NC32() MH32WP 32 30 NF43012 MH38 NC38() MH38WP 38 30 NF4301_2C MH38 NC38() MH38WP 38. 42 NF4421_2 MH44 NC44() MH44WP 44 42 NF4421_2C MH44 NC44() MH44WP 44 250 54 NF4541-2 MH50 NC50() MH50WP 56 54 NF454L2C MH50 NC50() MH50WP 56 66 NF4661_2 MH62 NC62() MH62WP 62 66 NF4661_2C MH62 NC62() MH62WP 62 30 NF4301_4 MH50 NC50V() MH50WP 50 30 NF4301_4C MH50 NC50V() MH50WP 50 42 NF4421_4 MH56 NC56V() MH56WP 56 42 NF442L4C MH56 NC56VO MH56WP 56 400 66 NF4661_4 MH74 NC74V() MH74WP 74 66 NF4661_4C MH74 NC74V() MH74WP 74 84 NF484L4 MH86 NC86V() MH86WP 86 84 NF4841_4C MH86 NC86V() MH86WP 86 30 NF4301-6C MH50 NC50V() 50 600 42 NF4421_6C MH56 NC56V() Factory Assembled 56 66 NF4661_6C MH74 NC74V() Only 74 84 NF484L6C MH86 NC86VO 86 800 Factory Assembled Only 1. "C' suffix indicates Copper bussing. 2. Type 1 enclosure catalogue numbers consist of MH plus the box height (example: MH44). Type 3R enclosure catalogue numbers add VJP to the Type 1 catalogue number (example: MH44VJP). . 3. Trim catalogue numbers consist of "NC" plus the box height plus "S" for surface trim or' F' for Bush Gm (example: NC44S). Trims for 400A and 60DA panels are vented and require a "V' after the height in the catalogue number (example: NC62VS). Add "HR" suffix to part number for hinged trims. 4. The maximum total amperage of two branch breakers mounted across from each other is 170A. 5. Embossed mounting holes add a 0.25 inch standoff to back of MH box. 6. End osures types 4 and 4X stainless steel are available factory assembled only. 7. Equipment ground bars must be ordered separately. 8. Additional panelboards with various maximum circuit numbers are available as Factory -assembled. Please contact your Schneider Electric Sales professional for details. F � 400A, 42 circuits Main lug interior with deadfront 400A interior Main lugs close-up DE5-12 Schneider 06112 QEleccrlc NQ Panelboards - Ready to Install (RTI) 20" Wide Enclosures — 240 Vac, 48 Vdc NQ Ready to Install Main Circuit Breaker Box Selection Table Main Circuit Breaker Interior, Order MLO Interior+ MCB Mounting Kit + MCB ` InteriorOnly Type 1 Enclosure Type 3R, 5,12 Enclosure Max no. 0 Single (ober branch =4't Main Vertical Circuit Breaker Tye Mains Rating Pole 00!008 breakers separately) Box 20"W x 5.75"D Front Box 20"W x 6.5"D Surge Circuit Breakers Redng Catalogue No. Kit Breaker Frames Catalogue No. I Catalogue No. Catalogue No. NO RTI 20" wide Single Phase 3 -Wire O6112 Schneider DE5-7 VElectric 18. NO181-7 MH38 NC38(S) or (F) MH38WP - 18 NO18L1C HD/HG/hUML MH38 NC38(S)or(F) MH38WP - 100 30 NO30Ll NOMB2HJ 100A max MH44 NC44(S)or(F) MFI44WP - 30 NO30LIC MH44 NC44(S)or(F) MH44WP - 30 NO301-2 HD/HG/FU/HL or MH44 NC44(S) or (F) MH44WP - 30 N0301-2G JO/JG/JJ/JLJD/JG/JJ/JL MH44 NC44(S)or(F) MH44WP - 42 NO421-2 MH50 NC50(S)or(F) MH50WP - 42 NO4212C 101-50 NC50(S)or(F) MH50WP - 225 72 NO721-2 NQMB2Q QBIQD/QJ/QL MH56 NC56(S)or(F) MH56WP - 72 NO721-2C MH56 NC56(S)or(F) MH56WP - 84 NO841-2 MH62 NC62(S) or (F) MH62WP - 84 NO84L2C NQMB2KI KI MH62 NC62(S)or(F) MH62WP - 30 NO301-4 MH62 NC62V(S) or (F) MH62WP - 30 NO301-4C MH62 NC62V(S) or (F) MH62WP - 400 42 NO421-4 NQMB4LA LAILH MH62 NC62V(S) or (F) MH62WP - 42 NO421-4C MH62 NC62V(S) or (F) MH62WP - 84 NO841-4C MH80 NC80V(S) or (F) MH80WP - 600 600 A MCB available factory assembled NO RTI 20" wide Three Phase 4 -Wire 18 NO418LI MH38 NC38(S) or (F) MH38WP - 18 NO418LIC HD/HG/FU/HL MH38 NC38(S)or(F) MH38WP - 100 30 NO430L1 NQMB2HJ 100A max MH44 NC44(S)or(F) MH44WP - 30 NO430LIC MH44 NC44(S)or(F) MFI44WP - 30 NO4301-2 MH44 NC44(S) or (F) MH44WP - 30 NO4301-2C MH44 NC44(S)or(F) MH44WP - 30 NQ430L2TVS212 NOMB2HJ HD/HGIFU/HLor MH62 NC62(S)or(F) MH62WP 120 30 NO430L2TVS216 JD/JG/JJ/JL MH62 NC62(S)or(F) MH62WP 160 30 NO4301-2TVS212C MH62 NC62(S)or(F) MH62WP 120 30 NO430LZlVS216C MH62 NC62(S)or(F) MH62WP 160 42 NO4421-2 MH50 NC50(S) or (F) MH50WP - 42 NO4421-2C MH50 NC50(S)or(F) MH50WP - 42 NO4421-2TVS212 MH68 NC68(S)or(F) MH68WP 120 42 NO442L2TVS216 MH68 NC68(S)or(F) MH68WP 160 225 42 NQ442L2TVS212C MH68 NC68(S)or(F) MH68WP 120 42 NO4421-2TVS216C MH68 NC68(S)or(F) MH68WP 160 54 NO4541-2 NOMB2O OBrOD/QJ/QL MFI50 NC50(S)or(F) MH50WP - 54 NO4541-2C MH50 NC50(S) or (F) MH50WP - 72 NO4721-2 MH56 NC56(S)or(F) MH56WP - 72 NO4721-2C MH56 NC56(S)or(F) MH56WP - 72 NO4721-2TVS212 MH74 NC74(S) or (F)' N/A 120 72 NO472LZTVS212C MH74 NC74(S)or(F) N/A 120 84 NO4841-2 MH62 NC62(S) or (F) MH56WP - 84 NO484L2C NQMB2Kl KI MH62 NC62(S)or(F) MH56WP - 30 - NO430L4 MH62 NC62V(S) or (F) MH62WP - 30 NO430L4C MH62 NC62V(S) or (F) MH62WP - 42 NO4421-4 MH62 NC62V(S) or (F) MH62WP - 42 NO4421-4C MH62 NC62V(S) or (F) MH62WP - 42 NO4421-4TVS212 MH80 NC80V(S) or (F) MH80WP 120 400 42 NO4421-4TVS216 NQMB4LA LA/LH MH80 NCSOV(S) or (F) MH80WP 160 42 NO4421-4TVS212C MH80 NC80V(S) or (F) MH80WP 120 42 NO4421-4TVS216C MH80 NC80V(S) or (F) MH80WP 160 72 NO4721-4 MH74 NC74V(S) or (F) MH74WP - 72 NO4721-4C MH74 NC74V(S) or'(F) MH74WP - 84 NO4841-4C MH80 NC80V(S) or (F) MH80WP - 600 600 A MCB available factory assembled O6112 Schneider DE5-7 VElectric r- gamut A Grainger Company HOME / ELECTRICAL / RELAYS. CONTACTORS, & SWITCHES / HAND -OPERATED SWITCHES & INDICATOR LIGHTS / SAFETY & DISCONNECT SWITCHES Product.Specs Phase: Number of Poles: Enclosure Material: Switch Rating: Output Power - Three Phase: Enclosure Height: Schneider Electric Heavy Duty Safety Disconnect Switch: Three Phase, 3 Poles, Steel, 200 A•@600V AC Switch Rating, Outdoor, Galvanized Item # 575R518 $1,720.20 Each Three 3 Steel 200 A @600V AC 125 hp @ 600V AC 291/4 in . Ent, osure Idth. 18 % in Enclosure Depth: 1 8 /2 i n 1 Enclosure Type: Outdoor NEMA Rating: NEMA 3R Application: Industrial; Commercial Current Type: AC/DC Duty: Heavy Duty Electrical Operating Life Cycles: Not Rated Enclosure Material Finish: Galvanized Flammability Rating: Not Rated For Fuse Clip Type: Class R Fusab le: Yes _.._...,. _.._.._._,,...,.. IP Rating: 14 Lead Size: 6/0 AWG Maximum Operating Temperature: Not Rated Mechanical Operating Life Cycles: Not Rated Minimum Operating Temperature: Not Rated Mounting Location: Indoor/Outdoor Mounting Style: Not Rated Neutral Assembly Included: No Number of Wires: 3 Pole -Throw Configuration: 3PST RoHS Compliant: Not Rated Specifications Met: UL Listed Termination Style: Not Rated Voltage: 600V DC; 600V AC Manufacturer Part Number: H364RB Compliance and Restrictions Country Of Origin USA About Install safety and disconnect switches on manufacturing equipment that may require an immediate disconnection of power from the source. Use these switches on devices that require frequent repairs, maintenance, or emergency stops. Similar Products 9�4 Standard -Duty Disconnect Switches Standard -Duty Double -Throw Disconnect ; 22 items 13 items ` {. 4 i Y �f� Heavy Duty Disconnect Switches Hazardous -Location Disconnect Switches i • - Y 18 items 4 items t r � � 4 t 1 r Air Conditioning Disconnect Swiltcies E 2 items , View More , support@Qamut.com 844 GO GAMUT (844.464.2688) Associated Products (1) Schneider Electric Safety Switch Bolt -On Hub: Bolt -On Hub. 0.75 in Compatible Conduit Trade Size, NEMA 3R. Rainticiht Item #630A767