HomeMy WebLinkAboutB17-2154 039-150-070_ a BUTTE COUNTY
DEPARTMENT OF DEVELOPMENT SERVICES <.� AREA5.
,
' INSPECTION CARD MUST BE ON JOB SITE. ."
24 Hour Inspection Line (IVR) : 530:538,4365 .(Cut.off time for inspections is 3pm)
,f,� • Development Services cannot guarantee inspections on the date requested. _
I DEVELOPMENT 'SERVICES Office: 530.538.7601, Fax: 530.538.7785 www.ButteCount,.net/dds
t` Permit No: B 17-2154 Issued:.. 9/12/2017
* W APN: 039-150-070
Address: 1191. CROUCH AVE, CHICO
Owner: ENNS FAMILY TRUSTt
m Permit Type: SOLAR ROOF -RES,
Description: Install 9.66kw roof mount to existing meter, ,
SETBACKS f6r Zoning- AG_ SRA. PW
Front: : Centerline of Road:" r
Rear: SRA:
Street: AG:
Interior
Total Setback from Centerline of Road:
ALL PLAN REVISIONS MUST BE APPROVED BY^THE COUNTY BEFORE=PROCEEDING • a y
InspectionType `
IVR INSP DATE
Setbacks
131= _ ' • .
Foundations / Footings :
1'11
Pier/Column' Footings
122
Eufer Ground
216 '
Masonry Grout I
120,•-
Do Not. Pour Concrete Until Above are Signed. -
Pre -Slab
124
Gas Test Underground/floor ' .
404 '
Gas Piping Vnderground/floor
403
Underfloor Framing
149
Underfloor Ducts
319',
Shear Transfer
.136
'Under Floor Plumbing
412: _
Under Slab Plumbing
411
Do Not'Install Floor Sheathing or Slab Until Above Signed
ShearwallB.W.P.-Interior
134
ShearwallB.W.P.-Exterior
135'
Roof Nail/Drag.Trusses-
129
Do Not Install Siding/Stucco or Roofing Until Above Signed
Rough Framing
153
Rough Plumbing _
406
' Inspection Type . ' -'IVR- INSP:' DATE
T'Bar Ceilin 145
Stucco Lath, 142,' f
Swimming Pools
Setbacks ., 131
Pool Plumbing Test 504
-Gas Test 404
Pre=Gunite- , 506
' Pre -Deck b • • 505
Pool Fencing/Alarms/Barriers 503
i Pre -Plaster' `: - 507
Manufactured Homes 1'
'
Setbacks' ? • 131
Blockin nde inin 612
Tiedown/Soft Set System 611 t.
PermanentFoundation System 613
Underground Electric ' 218
Continuity Test 602'
Skirtin /Ste s/Landin s 610
Permit Final
802 (W-1) a ;
Electrical Final
803
Mechanical Final
809 '
Plumbing Final
813
Fire Sprinkler Test or -Final
702
,.
Public.Works Final ' - 538.7681
i Fire .De' `artment/CDF 538.6226
Env. HealthFinal , ' 538.7281
Sewer District Final
11
'PROJECT FINAL .
4 . *Project Ficial is a Certificate of Occupancy for (ResidentialOnly)
PERMITS BECOME NULL AND VOID I YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A 1 YEAR
RENEWAL 30 DAYS PRIOR TO EXPIRATION .
PROJECT OWNER:
ENNS, ED & ELIZABETH
1191 CROUCH AVE
CHICO, CA 95928
APN:039-150-070 PH#:530.342.3539
EMAIL:ironbellforge@gmail.com
LEASE #:1179205
CONTRACTOR:
ALTERNATIVE ENERGY SYSTEMS INC.
13620 HIGHWAY 99
CHICO, CA 95973
CSLB: 853351. C-10, C-46
BUILDING JURISDICTION:
BUTTE COUNTY
DEPT. OF DEVELOPMENT SERVICES
7 COUNTY CENTER DRIVE
OROVILLE, CA 95965
OFFICE#: (530) 538-7601
FAX#: (530) 538-2140
MON-FRI 8AM-3PM
INSPECTION LINE: (530) 538-4365
REQUESTS PHONED IN BY 2PM WILL BE
INSPECTED THE NEXT BUSINESS DAY
bqkwe�
SCOPE:
INSTALL PHOTOVOLTAIC SOLAR SYSTEM ON A TRUSS
ROOF, MOUNTED IN ACCORDANCE WITH ALL
APPLICABLE BUILDING -CODES SPECIFICALLY .
REFERENCING THE 2016 CALIFORNIA ELECTRICAL
CODE/ 2014 NEC USING THE FOLLOWING SPECIFIC
EQUIPMENT:
1. MODULES: SUNPOWER
(28) SPR -X21 -345 -D -AC
9.66kW SYSTEM
512 SQFT COVERED
cool
PAGE # CONTENT
PV -1.0 SCOPE
PV -2.0 SITE PLAN
PV -3.0 ARRAY LAYOUT
PV -4.0 ELECTRICAL DIAGRAM
PV -4.1 LABEL DIAGRAM
PV -5.0 GENERAL NOTES
ATTACHMENT MODULE SPECS
INVERTER SPECS
RACKING SPECS
WIRE CALCS
2. INVERTER(S): SUNPOWER:
(28) MODULE INTEGRATED 320W EACH .{ ,
SITE MAP
1. .. * .v., :af r t. i�P?i�4 �, l:t J ,:rte •i�].:siE•� s+lla .....aT t ...__ ... _ .. ,. r.. -� -
m
a
3
S
ENNS, ED &ELIZABETH
13620 HWY 99
m
m
o
S
ENNS, ED &ELIZABETH
13620 HWY 99
o
m
Energy For Life
CHINO, CA 95973
C
m
0
m
1191 CROUCH AVE
i.'
a
A
o
-
PHONE#: (530) 345 6980
p
D A'z
`"
o o
CHINO, CA 95928
+
FAX#: (530) 892-2360
` ,
v
o
APN:039 150-070 PH#:530.342.3539
Energy Systems Alternative Ener 5 Inc. design@solarenergyforlife.com
Ln
Ci
cn
00
Ke
UJ
UJI Q.
ca uj
a-•
Or- x� w "I U 0r1 O
06 Z)
X _ -acs s - 1' r -I
U
�1C7 Z w. �' F. �' '"� ow o
m
m:� Z` vi U O
Wk `� F Z Z a
� � .,. _ DATE MODIFIED
--� Uf O:' - Y k w w 08/29/2017
Q'. DESIGNER
).SHANER
ZpZ .. ,,,,.• �, i. +� CORDINATOR
B. AG�IAR
h
SHEET
a PV -2.0
Jy
SITE PLAN
f
"To-
mmmmmmmmmn�iof"wrm-
INN
.0
F911M
o�rorommmmmmmem
,e�� .
e�� . o�� .
m'�:
e�� .
■�� o
�o�-�
a
oi�:ai��T�
q:
e�� a
s�o�:
■
"To-
mmmmmmmmmn�iof"wrm-
.0
F911M
o�rorommmmmmmem
o
omm
■■■■■■■
■
:Q
o
Ln 4
rl
r
LALL ROOF PENETRATIONS'
TO BE 72" O.C. MAXIMUM
• }` ARRAY LAYOUT ,
n m ° ^o m • a �" ENNS, ED &ELIZABETH _ 13620 HWY 99
p o m EneryyForuFe' CHICO, CA 95973
< Z 3 1191 CROUCH AVE -
s W > $ = A CHICO; CA 95928 PHONE#: (530) 345-6980
i
0 0 > T FAX#: (530) 892-2360
Z o APN:039-150-070 PH#:530.342.3539 Alternative Energy Systems Inc.
p A o design@solarenergyforlife.com
-\'I
(12) PV MODULES/INVERTERS
SUNPOWER:SPR-X21-345-D-AC
(12) PV MODULES/INVERTERS
SUN POWER: SPR -X21 -34S -D -AC
1.33A/1P/240V
4
(4) PV MODULES/INVERTERS
SUNPOWER:SPR-X21-345-D-AC
1.33A/1P/240V
'SERVICE VOLTAGE
120V-N-Ll-L2=240V
.
AC -2
AC -3
AC -1
-
(1) 3/4" EMT w/
(1) 3/4" EMT./
ON ROOF w/
(1) 1$14 THWN-2 CU. GRD.
(3) #8 THWN-2 CU. &
(3) #8 THWN-2 CU. &
(4) TRANSITION CABLE(S)
CAT -5
(1) #10 THWN-2 CU. GRD.
(1) #10 THWN-2 CU. GRD.
WIRE RUN: 5'
AC -1
WIRE RUN: 30'
WIRE RUN: 10'
IMP: 20A
(3) 430-2 WIRE NM CABLE CU.
IMAX: 47A
II��
IMAX: 47A
WIRE RUN: 30'
I
1 I
ROUTER
IMAX: 20A
n
'SERVICE VOLTAGE
120V-N-Ll-L2=240V
(N)AC DISTRIBUTION PANEL
125A/ 1P/ 240V
m8
20A
1P
240V
m
20A
1P
240V
D m
20A
1P
240V
(1) 1$14 THWN-2 CU. GRD.
15A
1P
240V
WIRE RUN: 30'
(N)AC DISTRIBUTION PANEL
125A/ 1P/ 240V
m8
AC -MONITORING
m
(1) 1/2" EMT w/
D m
(2) 114 THWN-2 CU. &
(1) 1$14 THWN-2 CU. GRD.
C) m
m 3
WIRE RUN: 30'
D ?
3 S
CAT -5
SUNPOWER
A
m
CHICO, CA 95928
PVSSX
�-
Circ
[�
MONITORING
- - -
APN:039-150-070 PH#:530.342.3539
ROUTER
20OA/ 1P/ 240V
SCIR: 10000
METER#: 1008261140
120% RULE
DOWNSIZE MAIN BREAKER IN
ACCORDANCE TO NEC 2014
ARTICLE 705.12(D)(2)
ELECTRICAL DIAGRAM
13620 HWY 99
For Life
Ener-ryy CHICO, CA 95973
�. PHONE#: (530) 345 6980
����®� FAM (530) 892-2360
Alternative Energy systems Inc.
design@solarenergyforlife.com
m8
m
ENNS, ED &ELIZABETH
D m
<
0
Z
C) m
m 3
1191 CROUCH AVE
D ?
3 S
>
p ;
A
m
CHICO, CA 95928
n z
o
o
APN:039-150-070 PH#:530.342.3539
,
'
-PV ARRAY�3
.• af.4
AC DISCONNECT
MAIN
SUB PANEL
HEE
j"'.
METER
..
++.,��
UH
.
�
i -
vacs ears
"
i
AMPS
.
PHASE
-p •+yI• -'i ., xL
••
- -
a
.
VOLTS
! •�-
•
i
- ti �
' .. s ,
. - -
t
vacs
�`• -
WARNING
UTILITY INTERACTIVE POWER
j
FLOWING THROUGH THIS PANEL
KW SOLAR GENERATOR
AC •,RATING VOLTAGE:
PHASE
WARNING
PHOTOVOLTAIC SYSTEM EQUIPPED
DUAL POWER SUPPLY
WITH RAPID SHUTDOWN
PHOTOVOLTAIC
SYSTEM
-
PER NEC 690.54 Interactive Point of
a
Interconnectin installed at all Electrical
Per NEC 705.10, Point of Connection, a«
e ••
- - _
. ,
Distribution Panel covers that porvidea �
;,
- Located On Main Service Panel. + '
v • - .. +'
path from PV to Utility.,.-
AC PHOTOVOLTAIC
DISCONNECT
FOR UTILITY
OPERATION
a
Per NEC 690.14, Disconnection means at
the single AC Disconnect or Main Breaker.
- 4
• ' -SOLAR
00 NOT RELOCATE-
-
Solar breaker label @ any breaker passing
- - ,— --
- Bi -Directional Power-
r�♦
LABEL DIAGRAM
r
m
8
m
D
ENNS, ED &'ELIZABETH y'
13620 HWY 99
L
• „
a
Energy For Life .
CH ICO, CA 95973
'
5 ` .0
a
m
0
1191 CROUCH AVE, +'
y
8
A
o
(�
PHONE#: (530) 345-6980
m A
3
=
m
CHICO, CA 95928 -
r
.®�l�'1J
FAX#:(530)892-2360
,
Z APN:039 150-070 PH#:530.342.3539
p
Alternative Energy Inca
f ! =
design@solarenergyforlife.com
ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE 2014
NATIONAL ELECTRIC CODE (NEC), OR LOCAL MUNICIPAL CODE, AND
FIRE DISTRICT REGULATIONS.
1. ALL EQUIPMENT SHALL BE LISTED AND LABELED PER RECOGNIZED ELECTRICAL TESTING LABORATORY AN
INSTALLED PER THE LISTING REQUIREMENTS AND THE MANUFACTURER'S INSTRUCTIONS.
2. ALL INVERTERS SHALL BE IEEE 929 COMPLIANT AND SHALL BE INSPECTED BY LOCAL UTILITY BEFORE
COMMISSIONING, TESTING, AND OPERATION OF THE SYSTEM.
3. ALL OUTDOOR EQUIPMENT SHALL BE MINIMUM NEMA 3R, INCLUDING OUTDOOR MOUNTED TRANSITION
BOXES, COMBINER BOXES, AND SWITCHES.
4. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ART.250,690.
5. NEC. ART. 690.9(A). ALL CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE OVERCURRENT
DEVICES LOCATED SO AS TO PROVIDE OVERCURRENT PROTECTION FROM ALL SOURCES.
6. NEC ART. 690.18. DUE TO THE FACT THAT PV MODULES ARE ENERGIZED WHENEVER THEY ARE EXPOSED
TO LIGHT, PV CONTRACTOR SHALL DISABLE THE ARRAY DURING INSTALLATION AND SERVICE BY SHORT
CIRCUITING, OPEN CIRCUITING, OR COVERING THE ARRAY WITH AN OPAQUE COVERING.
7. PHOTOVOLTAIC SYSTEM SHALL BACKFEED THE DISTRIBUTION SYSTEM ON SITE PER THE REQUIREMENTS OF
NEC ART.690.64(B). ALL BACKFEED BREAKERS SHALL BE IDENTIFIED AS SUCH AND SHALL BE SECURED IN
PLACE BY ADDITIONAL FASTENER PER THE REQUIREMENTS OF NEC 408.16(F) (408.36 IN 2014 NEC.
8. FALL ARREST PROTECTION PER OSHA REQUIREMENTS SHALL BE PROVIDED FOR ALL ROOF WORK.
9. ALL CONDUCTORS AND TERMINATIONS SHALL BE RATED FOR 75' C MINIMUM.
10. NEC ART. 690.14. - SEE SHEET RE -4.1 FOR LABEL DIAGRAM
11. NEC ART. 690.53. - SEE SHEET RE -4.1 FOR LABEL DIAGRAM
12. NEC ART. 690.17. EACH AC DISCONNECT SHALL ALSO BE LABELED WITH: "WARNING! -ELECTRICAL SHOCK
HAZARD - DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIZE MAY BE ENERGIZED IN
THE OPEN POSITION".
13. GROUNDING OF ALL DWELLINS SHALL BE CONFIRMED.
14. CONTRACTOR TO PROVIDE GROUND FAULT PROTECTION FOR ROOF MOUNTED PHOTOVOLTAIC ARRAYS
LOCATED ON DWELLINGS PER 2014 NEC ART.690.17.
15. WHERE MORE THAN ONE NOMINAL VOLTAGE SYSTEM EXIST, THE DIFFERENT SYSTEMS SHALL
BE IDENTIFIED BY PHASE AND SYSTEM PER 2014 NEC ART.210AD
16. PROVIDE AN ACCESSIBLE DISCONNECT DEVICE THAT IS LOCKABLE IN OPEN POSITION AND IS
LOCATED WITHIN 10'-0" OF THE METER PER LOCAL ELECTRICAL UTILITY REGULATIONS.
17. PHOTOVOLTAIC SOURCE CURRENTS MUST BERATED AT BOTH 125% OF THE PARALLEL
MODULE AND AT A CONTINUOUS LOAD OF ANOTHER 125% FOR A TOTAL OF 156% OF THE
LOAD.
18. PROVIDE PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE
DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECT MEANS IF THEY ARE
NOT IN THE SAME LOCATION PER 2014 NEC ART.690.56.
19. INSTALLATION OF PV PANEL ARRAYS SHOULD RESIST SLIDING AND POP-UP RESULTING FROM
SEISMIC EVENTS AND SHOULD COMPLY WITH CBC SECTION 1613A AND ASCE STANDARD 7-05,
CHAPTER 13.
20. PV SYSTEM INSTALLER WILL BE RESPONSIBLE FOR FURNISHING AND INSTALLATION OF ALL
RELATED EQUIPMENT, CABLES, ADDITIONAL CONDUITS, BOXES WIREWAYS AND OTHER
ACCESSORIES NECESSARY FOR COMPLETE AND OPERATIONAL PHOTOVOLTAIC SYSTEMS.
21. PV SYSTEM CONTRACTOR SHALL COORDINATE ALL THE WORK WITH THE ENGINEER, THE
CONSTRUCTION MANAGER AND ALL OTHER CONTRACTORS TO ENSURE THAT PV SYSTEM IS
INSTALLED AS SPECIFIED IN THESE DRAWINGS.
22. DRAWING IN GENERAL OR DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF THE
EQUIPMENT AND WORK INCLUDED. THE INTENTION OF THE DRAWING IS TO INDICATE SIZE,
CAPACITY, APPROXIMATE LOCATION AND GENERAL RELATIONSHIP, BUT NOT EXACT DETAIL
OR PHYSICAL PLACEMENT.
23. FIELD VERIFIES EXACT AIC RATING REQUIRED OF THE MAIN SWITCHBOARD FROM LOCAL
UTILITY.
24. A PV SYSTEM WITH MULTIPLE INVERTERS, WHERE INVERTERS ARE REMOTELY LOCATED FROM
EACH OTHER, WILL HAVE A DIRECTORY CREATED FOR EACH LOCATION. AS PER 2014 NEC
690.5(H) AND IN ACCORDANCE WITH 2014 NEC 705.10.
25. A NON FOLDING LADDER WILL BE IN PLACE AND SECURED TO THE ROOF TO PROVIDE ACCESS
FOR ALL INSPECTIONS. ALL J BOXES WILL BE OPENED UPON REQUEST.
26. SMOKE AND CARBON MONOXIDE ALARMS WILL BE INSTALLED IN ACCORDANCE WITH CRC R314
R315
"
m
ENNS, ED &ELIZABETH
13620 HWY 99
Z
o
m
Energy ForLl/e CHICO, CA 95973
<
Z
Z3
1191 CROUCH AVE
D
A
CHICO, CA 95928ti�
PHONE#1: (530) 345-6980
fq4wo���%yUI
p
D
>FAM
Z
o
APN:039 150-070 PH#:530.342.3539
(530) 892-2360
Alternative Energy Systems Inc.
design@solarenergyforlife.com
June 22, 2017
To Whom it May Concern,
In order to meet future advanced grid requirements, SunPower® is transitioning from Type C AC modules to Type D AC
modules. The purpose of this letter is to demonstrate the mechanical and electrical equivalency of Type C AC modules
and Type D AC modules. Type D AC modules are drop-in replacements for Type C AC modules and are available at the
same DC and AC power levels. Type D AC modules have the same form, fit, and function as Type C AC modules. The AC
electrical output specifications of Type C AC modules and Type D AC modules are equivalent, ensuring interchangeability
for AC conductors, overcurrent protection devices, and grounding.
SunPower Type D AC modules are certified per UL 1741 SA to the following SRDs: IEEE 1547, IEEE 1547a, and CPUC Rule
21 Phase 1. These additional certifications and functionality enable Type D AC modules to meet California CPUC Rule 21
Phase 1 smart inverter requirements. The following table lists the Type C AC module models and their respective Type D
equivalents, as of the date of this letter:
Where Type D AC modules are substituted in the field for Type C AC modules, no changes to the physical layout, structural
loading, electrical design, or interconnection are required.
Should you have any questions or concerns, please contact SunPower Technical Support at 1-800-786-7693.
Best Regards,
MAX:— "41-4
Matt Mayberry
Director, Residential Product Management
Type C AC M sd
E19 -320 -C -AC
s- DAC Modules -
E19 -320 -D -AC
E20 -327 -C -AC
E20 -327 -D -AC
X21-335-BLK-C-AC
X21-335-BLK-D-AC
X21 -335 -C -AC
X21 -335 -D -AC
X21 -345 -C -AC
X21 -345 -D -AC
X22 -360 -C -AC
X22 -360 -D -AC
Where Type D AC modules are substituted in the field for Type C AC modules, no changes to the physical layout, structural
loading, electrical design, or interconnection are required.
Should you have any questions or concerns, please contact SunPower Technical Support at 1-800-786-7693.
Best Regards,
MAX:— "41-4
Matt Mayberry
Director, Residential Product Management
r
Design -Driven Advantages
##1 module aesthetics and efficiency'
Unmatched module reliability2
No electrolytic capacitors
25 -year Combined Power and Product
Warranty
California Rule 21 Phase 1 compliant
Maximize Value for Roof
Size system for roof, not string inverter
Optimize performance of each module
Expand Deployment Options
Complex roofs and partial shading
Small systems
System expandability
Simplify & Speed' Installation
Factory -integrated microinverter
Robust, double -locking AC connectors
Design Flexibility offsite and onsite
No DC string sizing process
Fewer installation steps than competing
systems
Intuitive commissioning
Component of Complete System
Built for use with SunPower InvisiMountT"A
and the SunPower Monitoring System (PVS5x)
Superior system reliability and aesthetics
r
Optimize System and Installation Efficiency
X
SERIES
SunPower'''AC modules, which include a factory -integrated SunPower
microinverter, provide a revolutionary combination of high efficiency, high
reliability, and module -level DC -to -AC power conversion. Designed
specifically for use with SunPower InvisiMountl'� and the SunPower
Monitoring System, SunPower AC modules enable rapid installation, best -
in -class system aesthetics, and intuitive visibility into system performance.
All this comes with the best Combined Power and Product Warranty in
the industry.
Grid Support Utility -Interactive Smart Inverter
SanPower's new Type D AC module is UL tested and certified to UL 1741
SA and provides advanced smart inverter functions. SunPower Type D AC
modules are fully compliant with the Cali ornia Rule 21 Phase 1
requirements, and the Rule 21 grid profile is easily set during
commissioning with SunPower PVS5x monitoring hardware.
sunpower.com
.,, ... ,4
i
"s
.-
Optimize System and Installation Efficiency
X
SERIES
SunPower'''AC modules, which include a factory -integrated SunPower
microinverter, provide a revolutionary combination of high efficiency, high
reliability, and module -level DC -to -AC power conversion. Designed
specifically for use with SunPower InvisiMountl'� and the SunPower
Monitoring System, SunPower AC modules enable rapid installation, best -
in -class system aesthetics, and intuitive visibility into system performance.
All this comes with the best Combined Power and Product Warranty in
the industry.
Grid Support Utility -Interactive Smart Inverter
SanPower's new Type D AC module is UL tested and certified to UL 1741
SA and provides advanced smart inverter functions. SunPower Type D AC
modules are fully compliant with the Cali ornia Rule 21 Phase 1
requirements, and the Rule 21 grid profile is easily set during
commissioning with SunPower PVS5x monitoring hardware.
sunpower.com
r
9nay Z86£l5
alnpoAi�
Papu@wwoaab
' (gl 9.OZ) sql S -S -v
-spelap jq suononnsul uonellelsul pue /tales aql peal aseald
mom
aweJ3
u.®v®
ouneb le1u@wuOJ1AU3
OUneoa anna@uaJ
-nue tpm, ssep paadwal UOISSI SUeJ1-gnlH
sse19 ?uoJ j
Ill ua9 uoaxelni augle2s/uaoUOV\1 96
slla� JeloS
wwizosrs m�
anaowr
ww sss t
ADU@lay)3 UOISJanuo> DD JV/J4
T
%0.96
.
r Iul r 11
r
OE,
luaJJnD -xeW i
d H,1,
A ot7Z@
Lul rlpl
e
bD&
ww9pOt
Lul 9'E
�3
A Ot7Z@
I
ww LU
aaJi uonepeJDap paanpul-Ienualod ]Sal Old
pale) aJu V ssep
gulpuoq pue nulpunoiS paleJna?ul -
:(EOLZ In) Dul>taeJ ]unoingS1AUI pm pasn uaLiM
8 'ssep E00-S3D1 Pue CD3
(L)(3) - (V)EE'069 'SJo1a@uuOD DV S 1.069 D3N -
(leJJe agl aplslno .
pue aplsul) uMopingS P!ded Z L 069 :)3N
9.069 D3N
:g11M @aUepJOaae UI U011ellelSUl S@lg2u3 SUOneal111J@D
(DUpeJ aJy Z adGi) alnPOIN DV LVL L in,
(uona@Uuoaslp yeaq peol)
salgea pue SJolaauuo7 EOL6 in 'EOL9 in
Dulpun6jD ivauldlnb3 -
ivawdlnb3 uMopm IS pdey Ad -
L asegd I.Z @Ind
. VD 't7 LOZ-eLt'S L 3331 'EOOZ-Lt7S L 3331 :SoaS
HS LbL L in of pals!I in
- AiueJJeM lanpoJd pallwll Je@f-SZ
I'
/oueJJe!,,, Jamod pallwll Jea/-SZ sanueJJe/�
• •
•slaagselep/wo) jamoduns mmm aaagselep papuava aas •spelap ajow jo3
uonewjolul L DuaJa!a.i ajow loi meyworjamoduns-mm. aaS
-uolnnpad auunp sanleA JaMoo pa.inseaw 10 aaejane uo paseas
alnpow aql ulgllm, pauleluo° 611n1 sl a.010A ao pV •agellOA pue :H SaaV-1 ''ivaiinD SILOS
:pjepuelsuollejq!le�19'b.SZ'S'Ll•VV'a3uelPeJn:w!M000L1suoPipuoa!salPJePuels,
t •uopewolul a.low jot !0181£# ap!nD uonnllnsul xournbj agl aaS 3uluolsslwwoo
,. nuunp las alUo.id sguiiias iliiejaP Lc aVle Va'sSunlas llne!ap 6LOZ eLtS L rn lac /uoaej,
•spelap jot s.rwywoo jamoduns,m m aaS -E LOZ gad'.laded ailgm Jar+,odunS'„aged uonepeBao
alnpoh lamodunS„ le la .Z •neadwe:) palsal a jam, sJa.mvepuew lsagiel lg2la dol aql
•10lno awl •£ LOZ gaj'3Sa aaloqunejj ,.'ljodad apgnd annenlul /aplgelno alnpopy A&ul rues L#�
t I OZ -gaj /aunS alnpov,, uologd •slaued -egos uo7lps OOZ•£ Jano 10 lsaq'IH,
(WW CE)
`£) ul £XeIN
alnpoAi�
Papu@wwoaab
' (gl 9.OZ) sql S -S -v
- 1OGM
.UneJ VINVV ]saynlq) pa71poue >laelq I ssep
aweJ3
p@leJ J00p]np
ouneb le1u@wuOJ1AU3
OUneoa anna@uaJ
-nue tpm, ssep paadwal UOISSI SUeJ1-gnlH
sse19 ?uoJ j
Ill ua9 uoaxelni augle2s/uaoUOV\1 96
slla� JeloS
%S'S6
A 8OZcD
(s/w EZ) qdw ZS 1e Ileq Jalawe!P (ww SZ) gain L
@auelslsa8 ]aedwl
"'Joh zwfi? l L L9 'ed 0009 'isd SZ 1.:MouS
>peq,2 1uOJ} zw/3OJ SOE'ed OOOE'1sd Z9 :PuliVl
PeOI xelN
(D oOS) 3 oZZ L
'dwal lualgwV ,xelN
(D oS8+ 01 > e017-) 3 oS9 L+ of 3 Oti-
dwai D'uneJadp
• •M-10 I M_eI •_
(woud) ,Jarrod IeulwoN
nUlYaeJ1
lulod JaMod wnwlxew Iana1-alnpow paleJgalul •
sapolp ssed!(q aagi .
aaueJaloi apegS
Do/%6Z 0-
(JaMod) POD dwai
%O' LZ %S' LZ
slaua!auA laued •DAV
%0-/S+ %0-/S+
aaueJalOi JaMod
M SEE M SVE
(woud) ,Jarrod IeulwoN
DV-a-SK-LZX-MdS DV-a-StE-LZX-SdS
”
%S'S6
A 8OZcD
suonellelsul aseu,d E Jo; 2upueleq asegd @Arae ON
VA OZE 'M OH
JaMod 1
a/wl (alod omo) 0 L
(asegd algins) Z 1-
A 80Z@
A OvZ@
11naJID gaue)8 V OZ Jad s1lun .Xev
”
%S'S6
A 8OZcD
ADU@lay)3 UOISJanuo> DD JV/J4
%0.96
A ObZc�
V vs, L
A 80Z@I
luaJJnD -xeW i
d H,1,
A ot7Z@
A 8'8ZZ / 8OZ / EB I.
A 80Z@
agelloA
A b9Z / OvZ / Z' I I.Z
A Ot7Z@
I
JVA-1IOA
JaMod anllaead
JpA 69 L+
.rel S8.0 / 00• L /,Peal 58'0
OO'l, 100 I. / 66.0 •
Jolaea J81AOd
S'09 / 0.09 / S 85
S'09 / 0'09 / S'6S
(zH) /auanbad
•Xew / 'w0u / •U1W
'X2�w / •w0U / -Ulw
(s'un)as llnesap)
'
aluoJd (18S07
lZ alnb V�
L OZ-eLbS L 3331
Module* / Mid Clamp and Rail Module* / End Clamp and Rail
Mid Clamp End Clamp Rail & Rail Splice End Cap
i
Temperature-- -40° C to 90° C (-/-0° F to 194° F) -
Max. Load 2--00 Pa uplift
540G Pa downforce
Warranties
Component
Material
Weight
Mid Clamp -
Black oxide stainless steel AISI 304
63 g (2.2 07) '
End Clamp
Black anodi_ed aluminum alloy 6063-T6
110; (3.38 oz)
Rail
Black anodized aluminum alloy 6005-T6
830 9/m (9 oz/ft)
Rail Splice
Aluminum alloy 6005-T5
830 g/m (9 oz/.-'()
Ground Lug
Assembly
301 stainless
(A2-70 bolt; tin-plated copper lug)
1065 g/m. (3.75 d)
End Cap
Black acetal (POM) copolymer
10.4.g (037 oz)
Temperature-- -40° C to 90° C (-/-0° F to 194° F) -
Max. Load 2--00 Pa uplift
540G Pa downforce
Warranties
Composition Shingle Rafter Attachment
Application
Shingle Roof Decking Attachment
Curved and Flat Tile Roof Attachment
Curved
Certifications
Universal Interface for Other Roof Attachments
Temperature-- -40° C to 90° C (-/-0° F to 194° F) -
Max. Load 2--00 Pa uplift
540G Pa downforce
'•• - 5 • I.
Refer to roof attachment hardware manufacturers documentation
INIod.11e frame that is compatible with the IrvisnVount system required for hardware interoperability.. '
~ JO 2015 San Power Corporation, All Rights Reserved. SUN=OWcR, the SUNJ30WER logo, ard1VVISINIODUT are trademarks or registered - ` -
trademarks of Sun?ower Corporation. All other trademarks are the property of :heir respective owners. sunpower.com
Specifications included in this datasheet are subject to change without notice. Document #509506 Rev 3
Warranties
25 -year product warranty
5 -year finish warranty
UL 2703 Listed
Certifications
Class A fire i sting when distance between
roof surface acd bottom of Sun?ower
module frame is 5 3.5"
'•• - 5 • I.
Refer to roof attachment hardware manufacturers documentation
INIod.11e frame that is compatible with the IrvisnVount system required for hardware interoperability.. '
~ JO 2015 San Power Corporation, All Rights Reserved. SUN=OWcR, the SUNJ30WER logo, ard1VVISINIODUT are trademarks or registered - ` -
trademarks of Sun?ower Corporation. All other trademarks are the property of :heir respective owners. sunpower.com
Specifications included in this datasheet are subject to change without notice. Document #509506 Rev 3
INVISIMOUNT RACKING DETAIL
SOLAR MODULE
r- END CLA
11Y V 1J 11'IV MY 1 1\/"I1L
CLAMP
EACH MID CLAMP
GROUNDS THE
AIL
INVISIMOUNT RAIL
r
GreenFasten" GF1 — Product Guide
I
2
jt, I rV�4
F
Consult an engineer or go to www.ecofastensolar.com
for engineering data.
Installation Instructions with Compression Bracket
3 4a 4b 4c
1. Locate the rafters and snap horizontal and vertical lines to mark the installation position for
each GreenFasten flashing.
2. Drill a pilot hole (1/4" diameter) for the lag bolt. Backfill with sealant. EcoFasten Solar
recommends an EPDM mastic.
3. Insert the flashing so the top part is under the next row of shingles and pushed far enough
up slope to prevent water infiltration through vertical joint in shingles. The leading edge of
flashing must butt against upper row of nails to prevent turning when tourqued. See page
2.2 for vertical adjustment when leading edge of flashing hits nails in upper shingle courses.
4. Line up pilot hole with GreenFasten flashing hole.
4a Insert the lag bolt through the EPDM washer, the top compression component bracket (L-
102-3, L-102-6*, SCL-101-3*, Z-101*, Conduit Mount Bracket*) and the gasketed hole in the
flashing and into the rafter.
4b Insert the lag bolt through the EPDM washer, the Comp Mount Slide compression
bracket and the Basketed hole in the flashing and into the rafter.
4c Insert the lag bolt through the SS washer, the third -party bracket, the EPDM bonded
washer, the CP -SQ -Slotted compression bracket and the gasketed hole in the flashing
and into the rafter.
5. Torque: The range is between 100-140 torque inch -pounds depending on the type of wood
and time of year. The visual indicator for proper torque is when the EPDM on the underside
of the bonded washer begins to push out the sides as the washer compresses. If using an
impact wrench to install the fasteners be careful not to over torque the fastener. You may
need to stop and use a ratchet to finish the install.
*not pictured.
877-859-3947 EcoFasten Sola&All content protected under copyright. All rights reserved. 7/24/2014
EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 B2 8,153,700 B2 8,181,398 B2 8,166,713 B2 8,146,299 B2 8,209,914 B2 8,245,454 132 8,272,174 82 8,225,557 B2
2.1
GreenFasten" GF1 - Product Guide Installation Instructions
* Use for vertical adjustment when leading edge of flashing hits nails in upper shingle courses
. Slide flashing up under shingles until leading edge 2. Remove flashing and cut "V" notch at marks where nail shafts
engages nails. Measure remaining distance to adjust engaged leading edge of flashing the distance desired in Step 1.
—'^^^ Notch depth not to exceed 2"length by 1 /2" width..
shingle .
// Placement of "V" notch
1 � 7Ti
lip
3. Reinstall flashing with notched area upslope. 4. Position notched leading edge underneath nail heads as shown.
A.ate. Nails�'�A 7<t • • • _
w '4tr�.23s
neath shingle
lel �i•)�t3 -� 'ie� 9r ert !M1h 'rt lt3 St;- 7r' YY%fA
dj`ky
1 t.r �.i, ri 'n`'� (, ��{i 7 �,�_ � i xr;�. �.,r �'j�z f ia•>•'�A e� .'�l;r�' 4^y. n+��'1r �f'it
ti rrR i i"k rX,ry,F 4x.: .+.✓ ,y +. +u oSYt, 5 (Trj �' r ) r {# t ♦r T, r K(,) ry",
ty'y a.. ,�+y ,+..'�,•. J? tk < Ty a,�.t �i 'S. xTiZ;� ).y #yn��l kr.L .tet �i3,+ ��� Y djj!. �G � � ♦.,
� t � � r^" "'tn Yy .,-jb 9 ? ti . " a e - �• r » r � y � 3' ay t � +� , ✓fir
+c I t '? fr' ti ;F F+f ,�'+s 3n�rk, t+''� � t'di � J'�i' �`.r'•d rs 1_f e3"`^�r�' � r't rc � �_ }�)''•
� � ".X�S^,, �a tF'! a?, -�•:� kr � ,�. +.. rS+ *Y`u' �" rsS. Y.t' .a r n � y r t].Fr»,.
r
t,d t • 1 _� r , , 877-859-3947 EcoFasten Solan'All content protected under copyright. All rights reserved. 7/24/2014 2.2
EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 B2 8,153,700 B2 8,181,398 B2 8,166,713 B2 8,146,299 B2 8,209,914 B2 8,245,454 B2 8,272,174 B2 8,225,557 B2
GreenFAten" GF.1 - Product Guide 71 Cut Sheets: GF1
r Cf � J r � - • �yy:. .� R • } `ti 4y w . ` 7 • Tom- • e .. . ' l _ • • - . � • •' ,
tA ^ "y-
;�.)k . .
4
SECTION -A -A
t* C* Y 1 if 877-859-3947 Eco Fasten Sola&All content protected under copyright. All rights reserved. 7/24/2014 3.1
EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 B2 8,153,700 B2 8,181,398 B2 8,166,713 B2 8,146,299 B2 8,209,914 B2 8,245,454 B2 8,272,174 B2 8,225,557 82
GreenFasten" GIF 1 — Product -Guide . ' ; - Cut Sheets: GF,1- 812
Vi
Py VY' T. F.' V � T • .,� .
8"4X R— 1 /32 _ .
'��� ' ��'� ear+�, � _ t - .• .
K f�R:;•7
5 t .
[ E f `�
C : 166, ,..
r
����� `I ;�y�': - .. /� ' —a►1. .5/`64
4 16
DETAIL A
SCALE: 2:1
}7-� ��� � � - .. .. ----. - .V : .. z ---,.. .-.. t.... . ,� � .s ..,=:r..: .. � T—. - `ate•, _ •
Finish Options
BLK = Matte Black '
fy MILL =Mill Finish'
877-859-3947 EcoFasten SolaO All content protected under copyright. All rights reserved. 7/24/2014 r 3,2
EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 132 8,153,700 B218,181,398 82 8,166,713 132 8,146,299 132 8,209,914 82 8,245,454 132 8,272,174 132 8,225,557 B2
t' +oeq. � — 1' — 1.50—+♦ *
• cc 1. ° .'
0
Iy6 ll 'S0 r *s t
1
mm
2.00 — +•
t e r ,-jl 1.00
1t. Ol
t� tn1, 1.00 _ 00.38±.00 T 0.50
!I t / V 0 0.88±.01 X 820
•� y � - � :�jj� 2.00. ,
1877-859-3947 EcoFasten Solan' All content protected under copyright. All rights reserved. 7/24/2014 ' 3.3
EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 B2 8,153,700 B2 8,181,398 62 8,166,713 B2 8,146,299 B2 8,209,914 B2 8,245,454 B2 8,272,174 B2 8,225,557 B2
4
f.
. dill GreenFasten"-GF 1 — Product Guide +. Cut Sheets: Bracket Options - SCL-101-3"
3/8"
1" 46 SERRATIONS
WWI
to
! R1 /16"•
►.j'#
1'7/8"
t
.,
3/4" 1 /16"
R.005
j..i, R.010
F 2X R.01
60.000 !
Ry f •
.006
>� ,• 0 3/8"+.002 Y 1/8"
_
o DETAIL A '
7/8'.'X-82 SCALE 3:1
, Y z
877-859-3947 EcoFasten Sola&All content protected under copyright. All rights reserved. 7/24/2014 3.$
y''#� EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 132 8,153,700 B2 8,181,398 82 8,166,713 B2 8,146,299 132 8,209,914 132 8,245,454 132 8,272,174 B2 8,225,557 B2
GreenFasten'" GF1 — Product Guide a _Cut Sheets: Bracket Options - -102- "
,
fil
a
Tis ua +t -
( •
r
46 SERRATIONS
t I 14 r
tf !r!i 4 i to
7-1 712
r P�Y
it
w 4
N
X .
N
1 7/8"
A ,.
R1/1,6,
1/4
00
�t 1,
16"10
—j
A 05
,.
,o 11 t `n R.010
o 2 X R.01
q,.Q► •` w 60.00
3/8"+.006
-.002 -1/8"
.875 ±.010 X 820 DETAIL A y
SCALE 3: 1
Pu
,t rF
�9I ' 877-859-3947 •EcoFasten Solar'All content protected under copyright. All rights reserved. 7/24/2014 3.6
f! EcoFasten Solar by the following U.S. Patents: 8,151,522 B2 8,153,700 B2 8,181,398 B2 8,166,713 B2 8,146,299 B2 8,209,914 B2 8,245,454 82 8,272,174 B2 8,225,557 B2
1 'fit•+ a�� c i. ar products are pec ,
AC Circuit Ampacity Calculator Meter #:x'.10082611.40 '
Customer Name: ENNS, ED & ELIZABETH `
Location: 1191 CROUCH AVE, CHICO; CA 95928 _
Wire Note: AC -1 Description: AC MODULES TO AC DISTRIBUTION PANEL
Wire Calculation
3.84 kWatts 240• IVAC split Voltage Configuration I TRUE ITL Inverter?
10Minimum Wire and Conduit Size based on Voltage Drop and Ampacity Minimum Ground Size Based on NEC -
20.00 A Minimum Ciruit Breaker/Fuse Size 8 Actual Ground Size Based on NEC `
20.00 A Ampacity After Derate 10 Wire Size Based on Ampacity f 3.0 A
0.992 % of Voltage Drop 10 Wire Size Based on Voltage Drop 30 A
16 A Circuit Ampacity lFactor 1 Phases
:0.82 Conditions of Use Derate Factor
19.51 A Minimum Conductor Ampacity Based on Conditions of Use
20.00 A Minimum Conductor Ampacity Based on 1.25 Rule F
Conditions of lJse.'. - " = ,: - "��_ - _x,77 7 -
a` ,
0$2 Derate Total
50 °C Temp Coef (ambient + Sunlight) 122 °F r 0.82° Derate
50 °C Ambient Temp 1.22 °F -
none Sunlight Exposure 32 °F *C Temp adder
3 or less Number of Current Carrying Conductors 1 Derate applied to Temp Coeficient
V Ita a Dro :;Allowable Tolerance Solar Generation 1/0, Distribution 3% ' H "
o g _ p ( ° ).
240 V Circuit Voltage 16 A Circuit Amps 1.24 Resistance -
60 ft One Way Distance 10 Wire Size 0.992 % of Loss
Coriduit Siz79
e (.Conduit Fi11 Can Not`be more than 40%s) t' �- -= =
PVC Conduit Type 0.16 w Wire Size Diameter 13 Conduit Fill percentage
3/4 Conduit Size I 0.21-2 Ground Wire Size Diameter E0,409 Conduit Internal Diameter
600 V System Voltage THWN-2 Wire Type
13 A
AC Circuit Ampacity Calculator - : Meter #: .400,8261140
Customer Name: ENNS, ED & ELIZABETH ,
Location: 1191 CROUCH AVE, CHICO, CA 95,928 '
Wire Note: AC-2 Description: AC DISTRIBUTION PANEL TO MAIN
Wire Calculation o
8.96 kWatts 240 - VAC Split Voltage Configuration TRUE TL Inverter?
10 Minimum-Wire and Conduit Size based on Voltage Drop and Ampacity. Minimum Ground Size Based on NEC
46:67 A . Minimum Ciruit Breaker/Fuse Size 10 Actual Ground Size Based on NEC
46.67 A Ampacity After Derate LO
Wire Size Based on Ampacity ]3_6
A
• 0 % of Voltage Drop Wire Size Based on Voltage Drop A
37.333 A Circuit Ampacity 1 Factor 1Phases
0.82 Conditions of Use Derate Factor '
45.53'A Minimum Conductor Ampacity Based on Conditions of Use
46.671A Minimum Conductor Ampacity Based on 1.25 Rule ,
Coriditions,.of Use�� , - _
0.82 Derate Total.
50 °C Temp Coef (ambient + Sunlight) 122 °F 0.82 Derate
50 °C Ambient Temp 122 °F
none Sunlight Exposure 32 °F 0 °C Temp adder -
3 or less Number of Current Carrying Conductors Derate applied to Temp Coeficient
Voltage Drop: Allowable Tole-ranee (So.lar Ge.ne:ration 1%; Distribution 3%,)'�• - 1
:2401V Circuit Voltage 37333 JA Circuit Amps 1.24 Resistance
ft One Way Distance r 10, Wire Size 0 % of Loss
Conduit Size (Conduit.Fill Can Not be more than 40%) ':� $,
EMT Conduit Type - s0
,16y Wire Size Diameter % Conduit Fill percentage '
1 Conduit Size 0,16 Ground Wire Size Diameter 0:86.4 Conduit Internal Diameter
600 V System Voltage THWN-2 Wire Type
Carbon monoxide alarms required by Sections R3.15.1 and R31.5.2 shall be. installed in the
following locations:
1. Outside of each separate dwelling unit sleeping area in the immediate vicinity of the
bedroom(s).
2. On every level of a, dwelling unit including basements.
8315.1.5 Multiple -purpose alarms: Carbon monoxide alarms combined with smoke alarms
shall comply with Section R315, alb applicable, standards, and requirements, for listing and
approval by the Office of the State Fire Marshal, for smoke alarms.
Y
Bute County's Interpretation of 2013. CRC, Sections 314 & 315 for
Smoke Alarms & Carbon Monoxide Alarms:
Where alterations, repairs or additions exceeding 51,000 in valuation, existing dwellings shall be;
retrofitted with smoke alarms and those that have attached aarazes or fuel -burning appliances shall have
carbon monoxide alarms installed. Existing smoke alarms can be replaced with dual function alarms for
Smoke and Carbon Monoxide and in most cases will comply with the aforementioned code requirements
for Carbon Monoxide Alarms.
DECLARATION OF INS7ALLATION UNDER THE PENALTY OF iPERJUR
As Owner/Contractor, Vwe: affirm anddeclare under the penalty of perjury, under the laws
of the State of California, by our signatures below as Owner/Contractor,. that.!/we will
comply prior to final inspection with Items A & B as specified herein:
A. Both Owner/Contractor have read and clearly understand the aforementioned 2010
California Residential Code (CRC) Carbon Monoxide Alarm requirements.
B. Both Owner/Contractor are responsible for installing Carbon Monoxide Alarms prior to
final inspection as per the aforementioned building code and maintaining such
installation. Smoke Alarms will also be installed prior to final inspection -as per the 2010
CRC. .
Smoke and Carbon Monoxide alarms are now- installed in the following locations
Owner's name (print): L L 2 �
9A - _ ,
Owner's signature:
®ate:
Contractor's name (print)"_ (M �q 4 L4 Pf, CSLB License: aJr,35/ — G`10l
Contractor's signature: /% Date: `7 �•,S' ' 7
Project Address: 641'10)uc_� #: 7
Page 2 of 2
L Butte County Department of Development Services FORM NO
PERMIT CENTER
: 7 County Center Drive, Oroville, CA 9'5965 DBI 01
.:•�1 Main Phone(530) 538-7601 Fax.(530) 538-7735
Declaration of Installation
-for Smoke Alarms and Carbon, Ftielaoxide Alarms
The newly' adopted 2013 California Residential Code requires the instal'l'ation: of Carbon
Monoxide Detectors in dwelling units and in sleeping units within which, fuel'-burniing; appliances
are installed and in dwelling: units. that have attached: garages. -The policyfor Carbon Monoxide
Alarms in Butte Co unty. states.,.'Any- permit obtained i'n which the value of'work. exceeds $1000
associated with a Residential Group R Dwelling Unit or�Sleeping Unit shall: conform th, the
following 2013 California Residential Code requirements. for Smoke and Carbon Monoxide
Alarms (Section 8314 & R345).°
2.013 California Residential Code requirements for Carbon. blo noxide Alarms:
R315.1 New construction: An approved carbon monoxide alarm shall be, install'edi [n,dweling
units and in sleeping units: within which fuel burning appliances are. installed anal ini dwelling,
units that have. attached garages.
R315.1.2 Power supply:. For new- construction required! carbon monoxide, alarms shaft receive
their primary power from the building wiring where. such wiring is served; from a comrnerciall
source and: shall! be equipped with a battery, back-up. Alarm wiring, shall' be, directly connected to
the permanent building wiring without a disconnecting; switch other than as requiredi fo-over
curre.nt p.rotestion.
Erceptions:-
1_ In dwelling unitswhere there is no commercial. power supply the carbonmonoxi&alarm maybe solely
battery operated.
2. In existing dwelling units a carbon monoxide alarm is permitted to be: solely battery operated where
repairs or alterations do not resultin the removal of wall.and ceiling finishes
or there is no access by mewls of attic, basement or crawl space.
IR315..9.3 interconnection. Where more than: one carbon, monoxide alarm is required to be
installed within the dwelling unit or within a sleeping unit th&alarm! shall be interconnected ina
manner that activation of one alarm shall activate all of the alarms in the individ'uat unit.
,Exception:
1. Interconnection is not required in existing dwelling units where repairs, do! not result in. the.
removal of wall -and ceilingrnishes there is no access by means of attic, basement.orcrwM
space, and' no previous rne;hod for interconnection existed'.
RM.2 Where required in existing dwellings: Where a permit is required for: alterations,
repairs or additions exceeding one thousand dollars ($1,000), existing, dwellings -or sleeping
units that have attached' garages or fuel -burning appliances shall be provided`with a carbon
monoxide alarm in accordance with Section R315.1. Carbon monoxide alarms shall only be
required in the specific dwelling unit or sleeping unit for which the permit was obtained:.
R3'15.2.6 Alarm requirements: No person shall install, market, distribute, offer for.sal.e or sell
any carbon monoxide device in the State of California unless the device and instructions have
been approved and listed by the State Fire Marshal.
PZee l of ?