Loading...
HomeMy WebLinkAboutB17-2154 039-150-070_ a BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES <.� AREA5. , ' INSPECTION CARD MUST BE ON JOB SITE. ." 24 Hour Inspection Line (IVR) : 530:538,4365 .(Cut.off time for inspections is 3pm) ,f,� • Development Services cannot guarantee inspections on the date requested. _ I DEVELOPMENT 'SERVICES Office: 530.538.7601, Fax: 530.538.7785 www.ButteCount,.net/dds t` Permit No: B 17-2154 Issued:.. 9/12/2017 * W APN: 039-150-070 Address: 1191. CROUCH AVE, CHICO Owner: ENNS FAMILY TRUSTt m Permit Type: SOLAR ROOF -RES, Description: Install 9.66kw roof mount to existing meter, , SETBACKS f6r Zoning- AG_ SRA. PW Front: : Centerline of Road:" r Rear: SRA: Street: AG: Interior Total Setback from Centerline of Road: ALL PLAN REVISIONS MUST BE APPROVED BY^THE COUNTY BEFORE=PROCEEDING • a y InspectionType ` IVR INSP DATE Setbacks 131= _ ' • . Foundations / Footings : 1'11 Pier/Column' Footings 122 Eufer Ground 216 ' Masonry Grout I 120,•- Do Not. Pour Concrete Until Above are Signed. - Pre -Slab 124 Gas Test Underground/floor ' . 404 ' Gas Piping Vnderground/floor 403 Underfloor Framing 149 Underfloor Ducts 319', Shear Transfer .136 'Under Floor Plumbing 412: _ Under Slab Plumbing 411 Do Not'Install Floor Sheathing or Slab Until Above Signed ShearwallB.W.P.-Interior 134 ShearwallB.W.P.-Exterior 135' Roof Nail/Drag.Trusses- 129 Do Not Install Siding/Stucco or Roofing Until Above Signed Rough Framing 153 Rough Plumbing _ 406 ' Inspection Type . ' -'IVR- INSP:' DATE T'Bar Ceilin 145 Stucco Lath, 142,' f Swimming Pools Setbacks ., 131 Pool Plumbing Test 504 -Gas Test 404 Pre=Gunite- , 506 ' Pre -Deck b • • 505 Pool Fencing/Alarms/Barriers 503 i Pre -Plaster' `: - 507 Manufactured Homes 1' ' Setbacks' ? • 131 Blockin nde inin 612 Tiedown/Soft Set System 611 t. PermanentFoundation System 613 Underground Electric ' 218 Continuity Test 602' Skirtin /Ste s/Landin s 610 Permit Final 802 (W-1) a ; Electrical Final 803 Mechanical Final 809 ' Plumbing Final 813 Fire Sprinkler Test or -Final 702 ,. Public.Works Final ' - 538.7681 i Fire .De' `artment/CDF 538.6226 Env. HealthFinal , ' 538.7281 Sewer District Final 11 'PROJECT FINAL . 4 . *Project Ficial is a Certificate of Occupancy for (ResidentialOnly) PERMITS BECOME NULL AND VOID I YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A 1 YEAR RENEWAL 30 DAYS PRIOR TO EXPIRATION . PROJECT OWNER: ENNS, ED & ELIZABETH 1191 CROUCH AVE CHICO, CA 95928 APN:039-150-070 PH#:530.342.3539 EMAIL:ironbellforge@gmail.com LEASE #:1179205 CONTRACTOR: ALTERNATIVE ENERGY SYSTEMS INC. 13620 HIGHWAY 99 CHICO, CA 95973 CSLB: 853351. C-10, C-46 BUILDING JURISDICTION: BUTTE COUNTY DEPT. OF DEVELOPMENT SERVICES 7 COUNTY CENTER DRIVE OROVILLE, CA 95965 OFFICE#: (530) 538-7601 FAX#: (530) 538-2140 MON-FRI 8AM-3PM INSPECTION LINE: (530) 538-4365 REQUESTS PHONED IN BY 2PM WILL BE INSPECTED THE NEXT BUSINESS DAY bqkwe� SCOPE: INSTALL PHOTOVOLTAIC SOLAR SYSTEM ON A TRUSS ROOF, MOUNTED IN ACCORDANCE WITH ALL APPLICABLE BUILDING -CODES SPECIFICALLY . REFERENCING THE 2016 CALIFORNIA ELECTRICAL CODE/ 2014 NEC USING THE FOLLOWING SPECIFIC EQUIPMENT: 1. MODULES: SUNPOWER (28) SPR -X21 -345 -D -AC 9.66kW SYSTEM 512 SQFT COVERED cool PAGE # CONTENT PV -1.0 SCOPE PV -2.0 SITE PLAN PV -3.0 ARRAY LAYOUT PV -4.0 ELECTRICAL DIAGRAM PV -4.1 LABEL DIAGRAM PV -5.0 GENERAL NOTES ATTACHMENT MODULE SPECS INVERTER SPECS RACKING SPECS WIRE CALCS 2. INVERTER(S): SUNPOWER: (28) MODULE INTEGRATED 320W EACH .{ , SITE MAP 1. .. * .v., :af r t. i�P?i�4 �, l:t J ,:rte •i�].:siE•� s+lla .....aT t ...__ ... _ .. ,. r.. -� - m a 3 S ENNS, ED &ELIZABETH 13620 HWY 99 m m o S ENNS, ED &ELIZABETH 13620 HWY 99 o m Energy For Life CHINO, CA 95973 C m 0 m 1191 CROUCH AVE i.' a A o - PHONE#: (530) 345 6980 p D A'z `" o o CHINO, CA 95928 + FAX#: (530) 892-2360 ` , v o APN:039 150-070 PH#:530.342.3539 Energy Systems Alternative Ener 5 Inc. design@solarenergyforlife.com Ln Ci cn 00 Ke UJ UJI Q. ca uj a-• Or- x� w "I U 0r1 O 06 Z) X _ -acs s - 1' r -I U �1C7 Z w. �' F. �' '"� ow o m m:� Z` vi U O Wk `� F Z Z a � � .,. _ DATE MODIFIED --� Uf O:' - Y k w w 08/29/2017 Q'. DESIGNER ).SHANER ZpZ .. ,,,,.• �, i. +� CORDINATOR B. AG�IAR h SHEET a PV -2.0 Jy SITE PLAN f "To- mmmmmmmmmn�iof"wrm- INN .0 F911M o�rorommmmmmmem ,e�� . e�� . o�� . m'�: e�� . ■�� o �o�-� a oi�:ai��T� q: e�� a s�o�: ■ "To- mmmmmmmmmn�iof"wrm- .0 F911M o�rorommmmmmmem o omm ■■■■■■■ ■ :Q o Ln 4 rl r LALL ROOF PENETRATIONS' TO BE 72" O.C. MAXIMUM • }` ARRAY LAYOUT , n m ° ^o m • a �" ENNS, ED &ELIZABETH _ 13620 HWY 99 p o m EneryyForuFe' CHICO, CA 95973 < Z 3 1191 CROUCH AVE - s W > $ = A CHICO; CA 95928 PHONE#: (530) 345-6980 i 0 0 > T FAX#: (530) 892-2360 Z o APN:039-150-070 PH#:530.342.3539 Alternative Energy Systems Inc. p A o design@solarenergyforlife.com -\'I (12) PV MODULES/INVERTERS SUNPOWER:SPR-X21-345-D-AC (12) PV MODULES/INVERTERS SUN POWER: SPR -X21 -34S -D -AC 1.33A/1P/240V 4 (4) PV MODULES/INVERTERS SUNPOWER:SPR-X21-345-D-AC 1.33A/1P/240V 'SERVICE VOLTAGE 120V-N-Ll-L2=240V . AC -2 AC -3 AC -1 - (1) 3/4" EMT w/ (1) 3/4" EMT./ ON ROOF w/ (1) 1$14 THWN-2 CU. GRD. (3) #8 THWN-2 CU. & (3) #8 THWN-2 CU. & (4) TRANSITION CABLE(S) CAT -5 (1) #10 THWN-2 CU. GRD. (1) #10 THWN-2 CU. GRD. WIRE RUN: 5' AC -1 WIRE RUN: 30' WIRE RUN: 10' IMP: 20A (3) 430-2 WIRE NM CABLE CU. IMAX: 47A II�� IMAX: 47A WIRE RUN: 30' I 1 I ROUTER IMAX: 20A n 'SERVICE VOLTAGE 120V-N-Ll-L2=240V (N)AC DISTRIBUTION PANEL 125A/ 1P/ 240V m8 20A 1P 240V m 20A 1P 240V D m 20A 1P 240V (1) 1$14 THWN-2 CU. GRD. 15A 1P 240V WIRE RUN: 30' (N)AC DISTRIBUTION PANEL 125A/ 1P/ 240V m8 AC -MONITORING m (1) 1/2" EMT w/ D m (2) 114 THWN-2 CU. & (1) 1$14 THWN-2 CU. GRD. C) m m 3 WIRE RUN: 30' D ? 3 S CAT -5 SUNPOWER A m CHICO, CA 95928 PVSSX �- Circ [� MONITORING - - - APN:039-150-070 PH#:530.342.3539 ROUTER 20OA/ 1P/ 240V SCIR: 10000 METER#: 1008261140 120% RULE DOWNSIZE MAIN BREAKER IN ACCORDANCE TO NEC 2014 ARTICLE 705.12(D)(2) ELECTRICAL DIAGRAM 13620 HWY 99 For Life Ener-ryy CHICO, CA 95973 �. PHONE#: (530) 345 6980 ����®� FAM (530) 892-2360 Alternative Energy systems Inc. design@solarenergyforlife.com m8 m ENNS, ED &ELIZABETH D m < 0 Z C) m m 3 1191 CROUCH AVE D ? 3 S > p ; A m CHICO, CA 95928 n z o o APN:039-150-070 PH#:530.342.3539 , ' -PV ARRAY�3 .• af.4 AC DISCONNECT MAIN SUB PANEL HEE j"'. METER .. ++.,�� UH . � i - vacs ears " i AMPS . PHASE -p •+yI• -'i ., xL •• - - a . VOLTS ! •�- • i - ti � ' .. s , . - - t vacs �`• - WARNING UTILITY INTERACTIVE POWER j FLOWING THROUGH THIS PANEL KW SOLAR GENERATOR AC •,RATING VOLTAGE: PHASE WARNING PHOTOVOLTAIC SYSTEM EQUIPPED DUAL POWER SUPPLY WITH RAPID SHUTDOWN PHOTOVOLTAIC SYSTEM - PER NEC 690.54 Interactive Point of a Interconnectin installed at all Electrical Per NEC 705.10, Point of Connection, a« e •• - - _ . , Distribution Panel covers that porvidea � ;, - Located On Main Service Panel. + ' v • - .. +' path from PV to Utility.,.- AC PHOTOVOLTAIC DISCONNECT FOR UTILITY OPERATION a Per NEC 690.14, Disconnection means at the single AC Disconnect or Main Breaker. - 4 • ' -SOLAR 00 NOT RELOCATE- - Solar breaker label @ any breaker passing - - ,— -- - Bi -Directional Power- r�♦ LABEL DIAGRAM r m 8 m D ENNS, ED &'ELIZABETH y' 13620 HWY 99 L • „ a Energy For Life . CH ICO, CA 95973 ' 5 ` .0 a m 0 1191 CROUCH AVE, +' y 8 A o (� PHONE#: (530) 345-6980 m A 3 = m CHICO, CA 95928 - r .®�l�'1J FAX#:(530)892-2360 , Z APN:039 150-070 PH#:530.342.3539 p Alternative Energy Inca f ! = design@solarenergyforlife.com ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE 2014 NATIONAL ELECTRIC CODE (NEC), OR LOCAL MUNICIPAL CODE, AND FIRE DISTRICT REGULATIONS. 1. ALL EQUIPMENT SHALL BE LISTED AND LABELED PER RECOGNIZED ELECTRICAL TESTING LABORATORY AN INSTALLED PER THE LISTING REQUIREMENTS AND THE MANUFACTURER'S INSTRUCTIONS. 2. ALL INVERTERS SHALL BE IEEE 929 COMPLIANT AND SHALL BE INSPECTED BY LOCAL UTILITY BEFORE COMMISSIONING, TESTING, AND OPERATION OF THE SYSTEM. 3. ALL OUTDOOR EQUIPMENT SHALL BE MINIMUM NEMA 3R, INCLUDING OUTDOOR MOUNTED TRANSITION BOXES, COMBINER BOXES, AND SWITCHES. 4. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ART.250,690. 5. NEC. ART. 690.9(A). ALL CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE OVERCURRENT DEVICES LOCATED SO AS TO PROVIDE OVERCURRENT PROTECTION FROM ALL SOURCES. 6. NEC ART. 690.18. DUE TO THE FACT THAT PV MODULES ARE ENERGIZED WHENEVER THEY ARE EXPOSED TO LIGHT, PV CONTRACTOR SHALL DISABLE THE ARRAY DURING INSTALLATION AND SERVICE BY SHORT CIRCUITING, OPEN CIRCUITING, OR COVERING THE ARRAY WITH AN OPAQUE COVERING. 7. PHOTOVOLTAIC SYSTEM SHALL BACKFEED THE DISTRIBUTION SYSTEM ON SITE PER THE REQUIREMENTS OF NEC ART.690.64(B). ALL BACKFEED BREAKERS SHALL BE IDENTIFIED AS SUCH AND SHALL BE SECURED IN PLACE BY ADDITIONAL FASTENER PER THE REQUIREMENTS OF NEC 408.16(F) (408.36 IN 2014 NEC. 8. FALL ARREST PROTECTION PER OSHA REQUIREMENTS SHALL BE PROVIDED FOR ALL ROOF WORK. 9. ALL CONDUCTORS AND TERMINATIONS SHALL BE RATED FOR 75' C MINIMUM. 10. NEC ART. 690.14. - SEE SHEET RE -4.1 FOR LABEL DIAGRAM 11. NEC ART. 690.53. - SEE SHEET RE -4.1 FOR LABEL DIAGRAM 12. NEC ART. 690.17. EACH AC DISCONNECT SHALL ALSO BE LABELED WITH: "WARNING! -ELECTRICAL SHOCK HAZARD - DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIZE MAY BE ENERGIZED IN THE OPEN POSITION". 13. GROUNDING OF ALL DWELLINS SHALL BE CONFIRMED. 14. CONTRACTOR TO PROVIDE GROUND FAULT PROTECTION FOR ROOF MOUNTED PHOTOVOLTAIC ARRAYS LOCATED ON DWELLINGS PER 2014 NEC ART.690.17. 15. WHERE MORE THAN ONE NOMINAL VOLTAGE SYSTEM EXIST, THE DIFFERENT SYSTEMS SHALL BE IDENTIFIED BY PHASE AND SYSTEM PER 2014 NEC ART.210AD 16. PROVIDE AN ACCESSIBLE DISCONNECT DEVICE THAT IS LOCKABLE IN OPEN POSITION AND IS LOCATED WITHIN 10'-0" OF THE METER PER LOCAL ELECTRICAL UTILITY REGULATIONS. 17. PHOTOVOLTAIC SOURCE CURRENTS MUST BERATED AT BOTH 125% OF THE PARALLEL MODULE AND AT A CONTINUOUS LOAD OF ANOTHER 125% FOR A TOTAL OF 156% OF THE LOAD. 18. PROVIDE PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECT MEANS IF THEY ARE NOT IN THE SAME LOCATION PER 2014 NEC ART.690.56. 19. INSTALLATION OF PV PANEL ARRAYS SHOULD RESIST SLIDING AND POP-UP RESULTING FROM SEISMIC EVENTS AND SHOULD COMPLY WITH CBC SECTION 1613A AND ASCE STANDARD 7-05, CHAPTER 13. 20. PV SYSTEM INSTALLER WILL BE RESPONSIBLE FOR FURNISHING AND INSTALLATION OF ALL RELATED EQUIPMENT, CABLES, ADDITIONAL CONDUITS, BOXES WIREWAYS AND OTHER ACCESSORIES NECESSARY FOR COMPLETE AND OPERATIONAL PHOTOVOLTAIC SYSTEMS. 21. PV SYSTEM CONTRACTOR SHALL COORDINATE ALL THE WORK WITH THE ENGINEER, THE CONSTRUCTION MANAGER AND ALL OTHER CONTRACTORS TO ENSURE THAT PV SYSTEM IS INSTALLED AS SPECIFIED IN THESE DRAWINGS. 22. DRAWING IN GENERAL OR DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF THE EQUIPMENT AND WORK INCLUDED. THE INTENTION OF THE DRAWING IS TO INDICATE SIZE, CAPACITY, APPROXIMATE LOCATION AND GENERAL RELATIONSHIP, BUT NOT EXACT DETAIL OR PHYSICAL PLACEMENT. 23. FIELD VERIFIES EXACT AIC RATING REQUIRED OF THE MAIN SWITCHBOARD FROM LOCAL UTILITY. 24. A PV SYSTEM WITH MULTIPLE INVERTERS, WHERE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, WILL HAVE A DIRECTORY CREATED FOR EACH LOCATION. AS PER 2014 NEC 690.5(H) AND IN ACCORDANCE WITH 2014 NEC 705.10. 25. A NON FOLDING LADDER WILL BE IN PLACE AND SECURED TO THE ROOF TO PROVIDE ACCESS FOR ALL INSPECTIONS. ALL J BOXES WILL BE OPENED UPON REQUEST. 26. SMOKE AND CARBON MONOXIDE ALARMS WILL BE INSTALLED IN ACCORDANCE WITH CRC R314 R315 " m ENNS, ED &ELIZABETH 13620 HWY 99 Z o m Energy ForLl/e CHICO, CA 95973 < Z Z3 1191 CROUCH AVE D A CHICO, CA 95928ti� PHONE#1: (530) 345-6980 fq4wo���%yUI p D >FAM Z o APN:039 150-070 PH#:530.342.3539 (530) 892-2360 Alternative Energy Systems Inc. design@solarenergyforlife.com June 22, 2017 To Whom it May Concern, In order to meet future advanced grid requirements, SunPower® is transitioning from Type C AC modules to Type D AC modules. The purpose of this letter is to demonstrate the mechanical and electrical equivalency of Type C AC modules and Type D AC modules. Type D AC modules are drop-in replacements for Type C AC modules and are available at the same DC and AC power levels. Type D AC modules have the same form, fit, and function as Type C AC modules. The AC electrical output specifications of Type C AC modules and Type D AC modules are equivalent, ensuring interchangeability for AC conductors, overcurrent protection devices, and grounding. SunPower Type D AC modules are certified per UL 1741 SA to the following SRDs: IEEE 1547, IEEE 1547a, and CPUC Rule 21 Phase 1. These additional certifications and functionality enable Type D AC modules to meet California CPUC Rule 21 Phase 1 smart inverter requirements. The following table lists the Type C AC module models and their respective Type D equivalents, as of the date of this letter: Where Type D AC modules are substituted in the field for Type C AC modules, no changes to the physical layout, structural loading, electrical design, or interconnection are required. Should you have any questions or concerns, please contact SunPower Technical Support at 1-800-786-7693. Best Regards, MAX:— "41-4 Matt Mayberry Director, Residential Product Management Type C AC M sd E19 -320 -C -AC s- DAC Modules - E19 -320 -D -AC E20 -327 -C -AC E20 -327 -D -AC X21-335-BLK-C-AC X21-335-BLK-D-AC X21 -335 -C -AC X21 -335 -D -AC X21 -345 -C -AC X21 -345 -D -AC X22 -360 -C -AC X22 -360 -D -AC Where Type D AC modules are substituted in the field for Type C AC modules, no changes to the physical layout, structural loading, electrical design, or interconnection are required. Should you have any questions or concerns, please contact SunPower Technical Support at 1-800-786-7693. Best Regards, MAX:— "41-4 Matt Mayberry Director, Residential Product Management r Design -Driven Advantages ##1 module aesthetics and efficiency' Unmatched module reliability2 No electrolytic capacitors 25 -year Combined Power and Product Warranty California Rule 21 Phase 1 compliant Maximize Value for Roof Size system for roof, not string inverter Optimize performance of each module Expand Deployment Options Complex roofs and partial shading Small systems System expandability Simplify & Speed' Installation Factory -integrated microinverter Robust, double -locking AC connectors Design Flexibility offsite and onsite No DC string sizing process Fewer installation steps than competing systems Intuitive commissioning Component of Complete System Built for use with SunPower InvisiMountT"A and the SunPower Monitoring System (PVS5x) Superior system reliability and aesthetics r Optimize System and Installation Efficiency X SERIES SunPower'''AC modules, which include a factory -integrated SunPower microinverter, provide a revolutionary combination of high efficiency, high reliability, and module -level DC -to -AC power conversion. Designed specifically for use with SunPower InvisiMountl'� and the SunPower Monitoring System, SunPower AC modules enable rapid installation, best - in -class system aesthetics, and intuitive visibility into system performance. All this comes with the best Combined Power and Product Warranty in the industry. Grid Support Utility -Interactive Smart Inverter SanPower's new Type D AC module is UL tested and certified to UL 1741 SA and provides advanced smart inverter functions. SunPower Type D AC modules are fully compliant with the Cali ornia Rule 21 Phase 1 requirements, and the Rule 21 grid profile is easily set during commissioning with SunPower PVS5x monitoring hardware. sunpower.com .,, ... ,4 i "s .- Optimize System and Installation Efficiency X SERIES SunPower'''AC modules, which include a factory -integrated SunPower microinverter, provide a revolutionary combination of high efficiency, high reliability, and module -level DC -to -AC power conversion. Designed specifically for use with SunPower InvisiMountl'� and the SunPower Monitoring System, SunPower AC modules enable rapid installation, best - in -class system aesthetics, and intuitive visibility into system performance. All this comes with the best Combined Power and Product Warranty in the industry. Grid Support Utility -Interactive Smart Inverter SanPower's new Type D AC module is UL tested and certified to UL 1741 SA and provides advanced smart inverter functions. SunPower Type D AC modules are fully compliant with the Cali ornia Rule 21 Phase 1 requirements, and the Rule 21 grid profile is easily set during commissioning with SunPower PVS5x monitoring hardware. sunpower.com r 9nay Z86£l5 alnpoAi� Papu@wwoaab ' (gl 9.OZ) sql S -S -v -spelap jq suononnsul uonellelsul pue /tales aql peal aseald mom aweJ3 u.®v® ouneb le1u@wuOJ1AU3 OUneoa anna@uaJ -nue tpm, ssep paadwal UOISSI SUeJ1-gnlH sse19 ?uoJ j Ill ua9 uoaxelni augle2s/uaoUOV\1 96 slla� JeloS wwizosrs m� anaowr ww sss t ADU@lay)3 UOISJanuo> DD JV/J4 T %0.96 . r Iul r 11 r OE, luaJJnD -xeW i d H,1, A ot7Z@ Lul rlpl e bD& ww9pOt Lul 9'E �3 A Ot7Z@ I ww LU aaJi uonepeJDap paanpul-Ienualod ]Sal Old pale) aJu V ssep gulpuoq pue nulpunoiS paleJna?ul - :(EOLZ In) Dul>taeJ ]unoingS1AUI pm pasn uaLiM 8 'ssep E00-S3D1 Pue CD3 (L)(3) - (V)EE'069 'SJo1a@uuOD DV S 1.069 D3N - (leJJe agl aplslno . pue aplsul) uMopingS P!ded Z L 069 :)3N 9.069 D3N :g11M @aUepJOaae UI U011ellelSUl S@lg2u3 SUOneal111J@D (DUpeJ aJy Z adGi) alnPOIN DV LVL L in, (uona@Uuoaslp yeaq peol) salgea pue SJolaauuo7 EOL6 in 'EOL9 in Dulpun6jD ivauldlnb3 - ivawdlnb3 uMopm IS pdey Ad - L asegd I.Z @Ind . VD 't7 LOZ-eLt'S L 3331 'EOOZ-Lt7S L 3331 :SoaS HS LbL L in of pals!I in - AiueJJeM lanpoJd pallwll Je@f-SZ I' /oueJJe!,,, Jamod pallwll Jea/-SZ sanueJJe/� • • •slaagselep/wo) jamoduns mmm aaagselep papuava aas •spelap ajow jo3 uonewjolul L DuaJa!a.i ajow loi meyworjamoduns-mm. aaS -uolnnpad auunp sanleA JaMoo pa.inseaw 10 aaejane uo paseas alnpow aql ulgllm, pauleluo° 611n1 sl a.010A ao pV •agellOA pue :H SaaV-1 ''ivaiinD SILOS :pjepuelsuollejq!le�19'b.SZ'S'Ll•VV'a3uelPeJn:w!M000L1suoPipuoa!salPJePuels, t •uopewolul a.low jot !0181£# ap!nD uonnllnsul xournbj agl aaS 3uluolsslwwoo ,. nuunp las alUo.id sguiiias iliiejaP Lc aVle Va'sSunlas llne!ap 6LOZ eLtS L rn lac /uoaej, •spelap jot s.rwywoo jamoduns,m m aaS -E LOZ gad'.laded ailgm Jar+,odunS'„aged uonepeBao alnpoh lamodunS„ le la .Z •neadwe:) palsal a jam, sJa.mvepuew lsagiel lg2la dol aql •10lno awl •£ LOZ gaj'3Sa aaloqunejj ,.'ljodad apgnd annenlul /aplgelno alnpopy A&ul rues L#� t I OZ -gaj /aunS alnpov,, uologd •slaued -egos uo7lps OOZ•£ Jano 10 lsaq'IH, (WW CE) `£) ul £XeIN alnpoAi� Papu@wwoaab ' (gl 9.OZ) sql S -S -v - 1OGM .UneJ VINVV ]saynlq) pa71poue >laelq I ssep aweJ3 p@leJ J00p]np ouneb le1u@wuOJ1AU3 OUneoa anna@uaJ -nue tpm, ssep paadwal UOISSI SUeJ1-gnlH sse19 ?uoJ j Ill ua9 uoaxelni augle2s/uaoUOV\1 96 slla� JeloS %S'S6 A 8OZcD (s/w EZ) qdw ZS 1e Ileq Jalawe!P (ww SZ) gain L @auelslsa8 ]aedwl "'Joh zwfi? l L L9 'ed 0009 'isd SZ 1.:MouS >peq,2 1uOJ} zw/3OJ SOE'ed OOOE'1sd Z9 :PuliVl PeOI xelN (D oOS) 3 oZZ L 'dwal lualgwV ,xelN (D oS8+ 01 > e017-) 3 oS9 L+ of 3 Oti- dwai D'uneJadp • •M-10 I M_eI •_ (woud) ,Jarrod IeulwoN nUlYaeJ1 lulod JaMod wnwlxew Iana1-alnpow paleJgalul • sapolp ssed!(q aagi . aaueJaloi apegS Do/%6Z 0- (JaMod) POD dwai %O' LZ %S' LZ slaua!auA laued •DAV %0-/S+ %0-/S+ aaueJalOi JaMod M SEE M SVE (woud) ,Jarrod IeulwoN DV-a-SK-LZX-MdS DV-a-StE-LZX-SdS ” %S'S6 A 8OZcD suonellelsul aseu,d E Jo; 2upueleq asegd @Arae ON VA OZE 'M OH JaMod 1 a/wl (alod omo) 0 L (asegd algins) Z 1- A 80Z@ A OvZ@ 11naJID gaue)8 V OZ Jad s1lun .Xev ” %S'S6 A 8OZcD ADU@lay)3 UOISJanuo> DD JV/J4 %0.96 A ObZc� V vs, L A 80Z@I luaJJnD -xeW i d H,1, A ot7Z@ A 8'8ZZ / 8OZ / EB I. A 80Z@ agelloA A b9Z / OvZ / Z' I I.Z A Ot7Z@ I JVA-1IOA JaMod anllaead JpA 69 L+ .rel S8.0 / 00• L /,Peal 58'0 OO'l, 100 I. / 66.0 • Jolaea J81AOd S'09 / 0.09 / S 85 S'09 / 0'09 / S'6S (zH) /auanbad •Xew / 'w0u / •U1W 'X2�w / •w0U / -Ulw (s'un)as llnesap) ' aluoJd (18S07 lZ alnb V� L OZ-eLbS L 3331 Module* / Mid Clamp and Rail Module* / End Clamp and Rail Mid Clamp End Clamp Rail & Rail Splice End Cap i Temperature-- -40° C to 90° C (-/-0° F to 194° F) - Max. Load 2--00 Pa uplift 540G Pa downforce Warranties Component Material Weight Mid Clamp - Black oxide stainless steel AISI 304 63 g (2.2 07) ' End Clamp Black anodi_ed aluminum alloy 6063-T6 110; (3.38 oz) Rail Black anodized aluminum alloy 6005-T6 830 9/m (9 oz/ft) Rail Splice Aluminum alloy 6005-T5 830 g/m (9 oz/.-'() Ground Lug Assembly 301 stainless (A2-70 bolt; tin-plated copper lug) 1065 g/m. (3.75 d) End Cap Black acetal (POM) copolymer 10.4.g (037 oz) Temperature-- -40° C to 90° C (-/-0° F to 194° F) - Max. Load 2--00 Pa uplift 540G Pa downforce Warranties Composition Shingle Rafter Attachment Application Shingle Roof Decking Attachment Curved and Flat Tile Roof Attachment Curved Certifications Universal Interface for Other Roof Attachments Temperature-- -40° C to 90° C (-/-0° F to 194° F) - Max. Load 2--00 Pa uplift 540G Pa downforce '•• - 5 • I. Refer to roof attachment hardware manufacturers documentation INIod.11e frame that is compatible with the IrvisnVount system required for hardware interoperability.. ' ~ JO 2015 San Power Corporation, All Rights Reserved. SUN=OWcR, the SUNJ30WER logo, ard1VVISINIODUT are trademarks or registered - ` - trademarks of Sun?ower Corporation. All other trademarks are the property of :heir respective owners. sunpower.com Specifications included in this datasheet are subject to change without notice. Document #509506 Rev 3 Warranties 25 -year product warranty 5 -year finish warranty UL 2703 Listed Certifications Class A fire i sting when distance between roof surface acd bottom of Sun?ower module frame is 5 3.5" '•• - 5 • I. Refer to roof attachment hardware manufacturers documentation INIod.11e frame that is compatible with the IrvisnVount system required for hardware interoperability.. ' ~ JO 2015 San Power Corporation, All Rights Reserved. SUN=OWcR, the SUNJ30WER logo, ard1VVISINIODUT are trademarks or registered - ` - trademarks of Sun?ower Corporation. All other trademarks are the property of :heir respective owners. sunpower.com Specifications included in this datasheet are subject to change without notice. Document #509506 Rev 3 INVISIMOUNT RACKING DETAIL SOLAR MODULE r- END CLA 11Y V 1J 11'IV MY 1 1\/"I1L CLAMP EACH MID CLAMP GROUNDS THE AIL INVISIMOUNT RAIL r GreenFasten" GF1 — Product Guide I 2 jt, I rV�4 F Consult an engineer or go to www.ecofastensolar.com for engineering data. Installation Instructions with Compression Bracket 3 4a 4b 4c 1. Locate the rafters and snap horizontal and vertical lines to mark the installation position for each GreenFasten flashing. 2. Drill a pilot hole (1/4" diameter) for the lag bolt. Backfill with sealant. EcoFasten Solar recommends an EPDM mastic. 3. Insert the flashing so the top part is under the next row of shingles and pushed far enough up slope to prevent water infiltration through vertical joint in shingles. The leading edge of flashing must butt against upper row of nails to prevent turning when tourqued. See page 2.2 for vertical adjustment when leading edge of flashing hits nails in upper shingle courses. 4. Line up pilot hole with GreenFasten flashing hole. 4a Insert the lag bolt through the EPDM washer, the top compression component bracket (L- 102-3, L-102-6*, SCL-101-3*, Z-101*, Conduit Mount Bracket*) and the gasketed hole in the flashing and into the rafter. 4b Insert the lag bolt through the EPDM washer, the Comp Mount Slide compression bracket and the Basketed hole in the flashing and into the rafter. 4c Insert the lag bolt through the SS washer, the third -party bracket, the EPDM bonded washer, the CP -SQ -Slotted compression bracket and the gasketed hole in the flashing and into the rafter. 5. Torque: The range is between 100-140 torque inch -pounds depending on the type of wood and time of year. The visual indicator for proper torque is when the EPDM on the underside of the bonded washer begins to push out the sides as the washer compresses. If using an impact wrench to install the fasteners be careful not to over torque the fastener. You may need to stop and use a ratchet to finish the install. *not pictured. 877-859-3947 EcoFasten Sola&All content protected under copyright. All rights reserved. 7/24/2014 EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 B2 8,153,700 B2 8,181,398 B2 8,166,713 B2 8,146,299 B2 8,209,914 B2 8,245,454 132 8,272,174 82 8,225,557 B2 2.1 GreenFasten" GF1 - Product Guide Installation Instructions * Use for vertical adjustment when leading edge of flashing hits nails in upper shingle courses . Slide flashing up under shingles until leading edge 2. Remove flashing and cut "V" notch at marks where nail shafts engages nails. Measure remaining distance to adjust engaged leading edge of flashing the distance desired in Step 1. —'^^^ Notch depth not to exceed 2"length by 1 /2" width.. shingle . // Placement of "V" notch 1 � 7Ti lip 3. Reinstall flashing with notched area upslope. 4. Position notched leading edge underneath nail heads as shown. A.ate. Nails�'�A 7<t • • • _ w '4tr�.23s neath shingle lel �i•)�t3 -� 'ie� 9r ert !M1h 'rt lt3 St;- 7r' YY%fA dj`ky 1 t.r �.i, ri 'n`'� (, ��{i 7 �,�_ � i xr;�. �.,r �'j�z f ia•>•'�A e� .'�l;r�' 4^y. n+��'1r �f'it ti rrR i i"k rX,ry,F 4x.: .+.✓ ,y +. +u oSYt, 5 (Trj �' r ) r {# t ♦r T, r K(,) ry", ty'y a.. ,�+y ,+..'�,•. J? tk < Ty a,�.t �i 'S. xTiZ;� ).y #yn��l kr.L .tet �i3,+ ��� Y djj!. �G � � ♦., � t � � r^" "'tn Yy .,-jb 9 ? ti . " a e - �• r » r � y � 3' ay t � +� , ✓fir +c I t '? fr' ti ;F F+f ,�'+s 3n�rk, t+''� � t'di � J'�i' �`.r'•d rs 1_f e3"`^�r�' � r't rc � �_ }�)''• � � ".X�S^,, �a tF'! a?, -�•:� kr � ,�. +.. rS+ *Y`u' �" rsS. Y.t' .a r n � y r t].Fr»,. r t,d t • 1 _� r , , 877-859-3947 EcoFasten Solan'All content protected under copyright. All rights reserved. 7/24/2014 2.2 EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 B2 8,153,700 B2 8,181,398 B2 8,166,713 B2 8,146,299 B2 8,209,914 B2 8,245,454 B2 8,272,174 B2 8,225,557 B2 GreenFAten" GF.1 - Product Guide 71 Cut Sheets: GF1 r Cf � J r � - • �yy:. .� R • } `ti 4y w . ` 7 • Tom- • e .. . ' l _ • • - . � • •' , tA ^ "y- ;�.)k . . 4 SECTION -A -A t* C* Y 1 if 877-859-3947 Eco Fasten Sola&All content protected under copyright. All rights reserved. 7/24/2014 3.1 EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 B2 8,153,700 B2 8,181,398 B2 8,166,713 B2 8,146,299 B2 8,209,914 B2 8,245,454 B2 8,272,174 B2 8,225,557 82 GreenFasten" GIF 1 — Product -Guide . ' ; - Cut Sheets: GF,1- 812 Vi Py VY' T. F.' V � T • .,� . 8"4X R— 1 /32 _ . '��� ' ��'� ear+�, � _ t - .• . K f�R:;•7 5 t . [ E f `� C : 166, ,.. r ����� `I ;�y�': - .. /� ' —a►1. .5/`64 4 16 DETAIL A SCALE: 2:1 }7-� ��� � � - .. .. ----. - .V : .. z ---,.. .-.. t.... . ,� � .s ..,=:r..: .. � T—. - `ate•, _ • Finish Options BLK = Matte Black ' fy MILL =Mill Finish' 877-859-3947 EcoFasten SolaO All content protected under copyright. All rights reserved. 7/24/2014 r 3,2 EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 132 8,153,700 B218,181,398 82 8,166,713 132 8,146,299 132 8,209,914 82 8,245,454 132 8,272,174 132 8,225,557 B2 t' +oeq. � — 1' — 1.50—+♦ * • cc 1. ° .' 0 Iy6 ll 'S0 r *s t 1 mm 2.00 — +• t e r ,-jl 1.00 1t. Ol t� tn1, 1.00 _ 00.38±.00 T 0.50 !I t / V 0 0.88±.01 X 820 •� y � - � :�jj� 2.00. , 1877-859-3947 EcoFasten Solan' All content protected under copyright. All rights reserved. 7/24/2014 ' 3.3 EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 B2 8,153,700 B2 8,181,398 62 8,166,713 B2 8,146,299 B2 8,209,914 B2 8,245,454 B2 8,272,174 B2 8,225,557 B2 4 f. . dill GreenFasten"-GF 1 — Product Guide +. Cut Sheets: Bracket Options - SCL-101-3" 3/8" 1" 46 SERRATIONS WWI to ! R1 /16"• ►.j'# 1'7/8" t ., 3/4" 1 /16" R.005 j..i, R.010 F 2X R.01 60.000 ! Ry f • .006 >� ,• 0 3/8"+.002 Y 1/8" _ o DETAIL A ' 7/8'.'X-82 SCALE 3:1 , Y z 877-859-3947 EcoFasten Sola&All content protected under copyright. All rights reserved. 7/24/2014 3.$ y''#� EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 132 8,153,700 B2 8,181,398 82 8,166,713 B2 8,146,299 132 8,209,914 132 8,245,454 132 8,272,174 B2 8,225,557 B2 GreenFasten'" GF1 — Product Guide a _Cut Sheets: Bracket Options - -102- " , fil a Tis ua +t - ( • r 46 SERRATIONS t I 14 r tf !r!i 4 i to 7-1 712 r P�Y it w 4 N X . N 1 7/8" A ,. R1/1,6, 1/4 00 �t 1, 16"10 —j A 05 ,. ,o 11 t `n R.010 o 2 X R.01 q,.Q► •` w 60.00 3/8"+.006 -.002 -1/8" .875 ±.010 X 820 DETAIL A y SCALE 3: 1 Pu ,t rF �9I ' 877-859-3947 •EcoFasten Solar'All content protected under copyright. All rights reserved. 7/24/2014 3.6 f! EcoFasten Solar by the following U.S. Patents: 8,151,522 B2 8,153,700 B2 8,181,398 B2 8,166,713 B2 8,146,299 B2 8,209,914 B2 8,245,454 82 8,272,174 B2 8,225,557 B2 1 'fit•+ a�� c i. ar products are pec , AC Circuit Ampacity Calculator Meter #:x'.10082611.40 ' Customer Name: ENNS, ED & ELIZABETH ` Location: 1191 CROUCH AVE, CHICO; CA 95928 _ Wire Note: AC -1 Description: AC MODULES TO AC DISTRIBUTION PANEL Wire Calculation 3.84 kWatts 240• IVAC split Voltage Configuration I TRUE ITL Inverter? 10Minimum Wire and Conduit Size based on Voltage Drop and Ampacity Minimum Ground Size Based on NEC - 20.00 A Minimum Ciruit Breaker/Fuse Size 8 Actual Ground Size Based on NEC ` 20.00 A Ampacity After Derate 10 Wire Size Based on Ampacity f 3.0 A 0.992 % of Voltage Drop 10 Wire Size Based on Voltage Drop 30 A 16 A Circuit Ampacity lFactor 1 Phases :0.82 Conditions of Use Derate Factor 19.51 A Minimum Conductor Ampacity Based on Conditions of Use 20.00 A Minimum Conductor Ampacity Based on 1.25 Rule F Conditions of lJse.'. - " = ,: - "��_ - _x,77 7 - a` , 0$2 Derate Total 50 °C Temp Coef (ambient + Sunlight) 122 °F r 0.82° Derate 50 °C Ambient Temp 1.22 °F - none Sunlight Exposure 32 °F *C Temp adder 3 or less Number of Current Carrying Conductors 1 Derate applied to Temp Coeficient V Ita a Dro :;Allowable Tolerance Solar Generation 1/0, Distribution 3% ' H " o g _ p ( ° ). 240 V Circuit Voltage 16 A Circuit Amps 1.24 Resistance - 60 ft One Way Distance 10 Wire Size 0.992 % of Loss Coriduit Siz79 e (.Conduit Fi11 Can Not`be more than 40%s) t' �- -= = PVC Conduit Type 0.16 w Wire Size Diameter 13 Conduit Fill percentage 3/4 Conduit Size I 0.21-2 Ground Wire Size Diameter E0,409 Conduit Internal Diameter 600 V System Voltage THWN-2 Wire Type 13 A AC Circuit Ampacity Calculator - : Meter #: .400,8261140 Customer Name: ENNS, ED & ELIZABETH , Location: 1191 CROUCH AVE, CHICO, CA 95,928 ' Wire Note: AC-2 Description: AC DISTRIBUTION PANEL TO MAIN Wire Calculation o 8.96 kWatts 240 - VAC Split Voltage Configuration TRUE TL Inverter? 10 Minimum-Wire and Conduit Size based on Voltage Drop and Ampacity. Minimum Ground Size Based on NEC 46:67 A . Minimum Ciruit Breaker/Fuse Size 10 Actual Ground Size Based on NEC 46.67 A Ampacity After Derate LO Wire Size Based on Ampacity ]3_6 A • 0 % of Voltage Drop Wire Size Based on Voltage Drop A 37.333 A Circuit Ampacity 1 Factor 1Phases 0.82 Conditions of Use Derate Factor ' 45.53'A Minimum Conductor Ampacity Based on Conditions of Use 46.671A Minimum Conductor Ampacity Based on 1.25 Rule , Coriditions,.of Use�� , - _ 0.82 Derate Total. 50 °C Temp Coef (ambient + Sunlight) 122 °F 0.82 Derate 50 °C Ambient Temp 122 °F none Sunlight Exposure 32 °F 0 °C Temp adder - 3 or less Number of Current Carrying Conductors Derate applied to Temp Coeficient Voltage Drop: Allowable Tole-ranee (So.lar Ge.ne:ration 1%; Distribution 3%,)'�• - 1 :2401V Circuit Voltage 37333 JA Circuit Amps 1.24 Resistance ft One Way Distance r 10, Wire Size 0 % of Loss Conduit Size (Conduit.Fill Can Not be more than 40%) ':� $, EMT Conduit Type - s0 ,16y Wire Size Diameter % Conduit Fill percentage ' 1 Conduit Size 0,16 Ground Wire Size Diameter 0:86.4 Conduit Internal Diameter 600 V System Voltage THWN-2 Wire Type Carbon monoxide alarms required by Sections R3.15.1 and R31.5.2 shall be. installed in the following locations: 1. Outside of each separate dwelling unit sleeping area in the immediate vicinity of the bedroom(s). 2. On every level of a, dwelling unit including basements. 8315.1.5 Multiple -purpose alarms: Carbon monoxide alarms combined with smoke alarms shall comply with Section R315, alb applicable, standards, and requirements, for listing and approval by the Office of the State Fire Marshal, for smoke alarms. Y Bute County's Interpretation of 2013. CRC, Sections 314 & 315 for Smoke Alarms & Carbon Monoxide Alarms: Where alterations, repairs or additions exceeding 51,000 in valuation, existing dwellings shall be; retrofitted with smoke alarms and those that have attached aarazes or fuel -burning appliances shall have carbon monoxide alarms installed. Existing smoke alarms can be replaced with dual function alarms for Smoke and Carbon Monoxide and in most cases will comply with the aforementioned code requirements for Carbon Monoxide Alarms. DECLARATION OF INS7ALLATION UNDER THE PENALTY OF iPERJUR As Owner/Contractor, Vwe: affirm anddeclare under the penalty of perjury, under the laws of the State of California, by our signatures below as Owner/Contractor,. that.!/we will comply prior to final inspection with Items A & B as specified herein: A. Both Owner/Contractor have read and clearly understand the aforementioned 2010 California Residential Code (CRC) Carbon Monoxide Alarm requirements. B. Both Owner/Contractor are responsible for installing Carbon Monoxide Alarms prior to final inspection as per the aforementioned building code and maintaining such installation. Smoke Alarms will also be installed prior to final inspection -as per the 2010 CRC. . Smoke and Carbon Monoxide alarms are now- installed in the following locations Owner's name (print): L L 2 � 9A - _ , Owner's signature: ®ate: Contractor's name (print)"_ (M �q 4 L4 Pf, CSLB License: aJr,35/ — G`10l Contractor's signature: /% Date: `7 �•,S' ' 7 Project Address: 641'10)uc_� #: 7 Page 2 of 2 L Butte County Department of Development Services FORM NO PERMIT CENTER : 7 County Center Drive, Oroville, CA 9'5965 DBI 01 .:•�1 Main Phone(530) 538-7601 Fax.(530) 538-7735 Declaration of Installation -for Smoke Alarms and Carbon, Ftielaoxide Alarms The newly' adopted 2013 California Residential Code requires the instal'l'ation: of Carbon Monoxide Detectors in dwelling units and in sleeping units within which, fuel'-burniing; appliances are installed and in dwelling: units. that have attached: garages. -The policyfor Carbon Monoxide Alarms in Butte Co unty. states.,.'Any- permit obtained i'n which the value of'work. exceeds $1000 associated with a Residential Group R Dwelling Unit or�Sleeping Unit shall: conform th, the following 2013 California Residential Code requirements. for Smoke and Carbon Monoxide Alarms (Section 8314 & R345).° 2.013 California Residential Code requirements for Carbon. blo noxide Alarms: R315.1 New construction: An approved carbon monoxide alarm shall be, install'edi [n,dweling units and in sleeping units: within which fuel burning appliances are. installed anal ini dwelling, units that have. attached garages. R315.1.2 Power supply:. For new- construction required! carbon monoxide, alarms shaft receive their primary power from the building wiring where. such wiring is served; from a comrnerciall source and: shall! be equipped with a battery, back-up. Alarm wiring, shall' be, directly connected to the permanent building wiring without a disconnecting; switch other than as requiredi fo-over curre.nt p.rotestion. Erceptions:- 1_ In dwelling unitswhere there is no commercial. power supply the carbonmonoxi&alarm maybe solely battery operated. 2. In existing dwelling units a carbon monoxide alarm is permitted to be: solely battery operated where repairs or alterations do not resultin the removal of wall.and ceiling finishes or there is no access by mewls of attic, basement or crawl space. IR315..9.3 interconnection. Where more than: one carbon, monoxide alarm is required to be installed within the dwelling unit or within a sleeping unit th&alarm! shall be interconnected ina manner that activation of one alarm shall activate all of the alarms in the individ'uat unit. ,Exception: 1. Interconnection is not required in existing dwelling units where repairs, do! not result in. the. removal of wall -and ceilingrnishes there is no access by means of attic, basement.orcrwM space, and' no previous rne;hod for interconnection existed'. RM.2 Where required in existing dwellings: Where a permit is required for: alterations, repairs or additions exceeding one thousand dollars ($1,000), existing, dwellings -or sleeping units that have attached' garages or fuel -burning appliances shall be provided`with a carbon monoxide alarm in accordance with Section R315.1. Carbon monoxide alarms shall only be required in the specific dwelling unit or sleeping unit for which the permit was obtained:. R3'15.2.6 Alarm requirements: No person shall install, market, distribute, offer for.sal.e or sell any carbon monoxide device in the State of California unless the device and instructions have been approved and listed by the State Fire Marshal. PZee l of ?