Loading...
HomeMy WebLinkAboutB17-2150 064-090-014Ph tovoltaic System Conduit Conductor Schedule (ALL CONDUCTORS MUST BE COPPER) DC System Size (Wa �s)425S Tag N Description wire Gauge it of Conductors/Color I Conduit Type Conduit Size 1 2 AC System Size (Watts) 3450 1 Enphase Engage Cable THWN-2 112 AWG 3(L1, L2, G) IN/A-FreeAir N/A-FreeAir r,I oo ul ---k4odule/Inverter Count 15 1 Bare Copper Ground(EGC/GEC) 16 AWG _ -Free A -Free Air 1 BARE !!!/A ir N/A u, m Lr - 2 THWN - 2 110 AWG 2(1L1 11.2) B/R 3/4" EMT Wn 44, 11 r- nd 18 AWG 1(GRN) 3/4" Z ED 0 Y So &_41, Cf 3E LO 4--, 1, Ole Existing einformation: Type;YU6SP-29b count: 34 Existing PVCondblner Panel Existing inverter Inforrnation: Type: M215-60-2LL-S22-IG count: 34 0 VISIBLE LOCKABLE 'KNIFE' A/C DISCONNECT A/240V UNFUSED NEIVIA3 o R EQUIVALENT on ,r u — r.� oa oc I u, 5 cq 14 iin disconnect derated from 200A to o - S-� 6� 175A - do . z 20AT 20A Rapid Shuttle— Point ol 1, terconne�tion, Load L z Disconnect, Square D Sidc 7 5.12(D)(2)(3)(b) 20A OU22IRB, 240V/30A, I Unfused, NEMA3, or ow 5 5A A equivalent LI L2N z z Ln 2�A SHEET Inverter: Enphase IQ6-6012-US M Existing 240V/200A NAME: Service Panel, Sing.le .Y. OtEnvoy-S P '�S . I It hase,.ith 7 A ba N, P, % p, �75A Disconnect 120A E -P 40A SHEET �5. F.tinuous, 2 ;51.. 2 PV Ci rcu: t 1:,l 5 e, NUMBER: e, oupu;,t M.du es prwecfict. — 60A.,,-k.r,.n cornbirte, ouput; i Parallel Mth �GKAICclrcu t breakers, NEIVIA4 junction Box ith Weversible VjtsjjTe o=ck bj:e:�Kni a- NC IvIinIrnumGECsize4 G­.dSpIIc.tTYP) DIsC—ect AWG copper, LL; SOLAR MODULE Enphase L_ - Iq6.tt2-_-_ .. MICRO -INVERTER AT EACH MODULE, ATTACHED WITH ECOLIBRIUM SOLAR HARDWARE 96 BARE CU GROUND (ATTACHED TO FIRST MODULE IN ARRAY). BALANCE OF ARRAY GROUNDING CONNECTIONS MADE THROUGH ARRAY HARDWARE MICROINVERTER CONNECTION TO ENGAGE TRUNK CABLE . Inverter Make/Model IQ6-60-2-US Max. Dc Volt Rating 48 Volts Max. Power at 40 C . 230 Watts Nominal AC Voltage 240 Volts Max. AC Current 0.96 Amps Max. bCPD Rating 20 Amps Max. Lanel /Sircu-it 16 15 i,.� Cic. it CuFe�l 15 Amps inverter Make/Model M215-60-2LL-S22-IG Max. Dc Volt Rating 45 Volts Max. Power at 40 C 215 Watts Nominal AC Voltage 240 Volts AC Current 0.9 Amps -Max. Max. OCPD Rating 20 Amps Max. Panels/Circuit 17 15 Short Circuit Current is Amps Other Notes PV Module Rating @ STC 14.4 Module Make/Model JKM28SM-608 240 Max. Power -Point Current (imp) 8.9 Amps Max. Power -Point Voltage (Vmp) 32 Volts Open -Circuit Voltage (Voc) 38.7 Volts Short -Circuit Current (Isc) 9.65 7m`pT Max. Series Fuse (OCPD) 15 Amps Nom. Max. Power at STC (Pmax) 285 Watts Max. System Voltage 1000 V DC (UL) Voc Temperature Coefficient Voc Temperature Coefficient -0.29 7%_/C AC Outpu Current According to art. 690.8(B)(1) 14.4 �ps Nominal AC Voltage 240 1 . Vo ts THIS PANEL IS FED BY MULTIPLE SOURCES (UTILITY AND SOLAR� Rooftop conductor ampacities designed in compliance with art. 690.8, Tables 310.15(8)(2)(a), 310.15(B)(3)(a), 310.15(B)(3)(c), 310.15(B)(16), Chapter 9 Table 4, 5, & 9. Loacation specific temperature obtained from ASHRA 2013 data tables. ASHRAE 2013 - Highest Monthly 2% D.B. Design Temp.: 38.7 *C Lowest Min. Mean Extreme D.B.: -3.8 *C PV Module Rating @ STC Module Make/Model YL265P-29b Max. Power -Point Current (imp) 8.7 Amps Max. Power -Point Voltage (Vmp) 30.5 Volts Open -Circuit Voltage (Voc) 37.8 volts Short -Circuit Current (Isc) 9.18 Amps Max. Series Fuse (OCPD) is mps Nom. Max. Power at STC (Pmax) 265 Watts Max. System Voltage 1000 V (IEC) / 600 V JUL) Voc Temperature Coefficient -0.32 1 %/C Designed according to, and all code citations are relevant to, the CEC 2016. Utility Service Provided by PGE No battery back-ups are tied to the designed inverteds). Inverter(s) used in this design is/are compliant with 690.12 (Rapid Shutdown). See manufacturer data sheet Array grounding and bonding designed in compliance with 690.47(C)(3). Conductor Calculations - Wire gauge calculated from art. code 310.15(B)(16) with ambient temperature calculations from ti art. 310.15(2)(a). of modules per Circuit X (1.251art. 210.19(A)(1)(a))) X (0.96 Max AC current per micro -inverter) �; For.'On Roof" conductors we use the 90*C column ampacity, 0.5"-3.5" off -the -roof temperature system output current w/ continuous duty = 18 < 20A (System OCPD) adjustment from 310.15(8)(3)(c), and raceway fill adjustments from 310.15(B)(16). Z For "Off Roof" conductors we use the 75*C column ampacity, or the 90*C column ampacity with t; 0, the relevant ambient temperature and raceway fill adjustments, whichever is less. The rating of the conductor after adjustments MUST be greater than, or equal to, the continuous U duty uprated output current. Calculation Example - Wire Rating (90*C) x Ambient Temperature Adjustment x Conduit Fill AOJustment >= Continuous Duty Output Current (On Roof, Tag 2): 10gauge wire rated for40A, 40AxO.65x 1 (2 Conductors)= 26A>= 18A 0 (A 4bg C F__ OCPD Calculations eakers sized according to continuous duty output current. PV circuit nominal current based off # of modules per Circuit X (1.251art. 210.19(A)(1)(a))) X (0.96 Max AC current per micro -inverter) 0 Circuit Ill = 15 modules, Output Current w/ continuous duty = 18 < 20A Breaker system output current w/ continuous duty = 18 < 20A (System OCPD) Z t; '7 Inverter Grounded Systems Per 690.,5(g Main Service Panel Signage WARNING (Installed on the Face of the Service Meter) o, ELECTRICAL SHOCK HAZARD Per 690.54, 690.56(B), & 705.10 0 w IF A GROUND FAULT IS INDICATED, Note: Roofline placard not needed unless PV disconnect is not at the NORMALLY GROUNDED CONDUCTORS same location as the main service < 0 MAY BE UNGROUNDED AND ENERGIZED CAUTION: SOLAR ELECTRICAL SYSTEM CONNECTED Or U Combiner Boxes, J -Boxes, Disconnects, Devices, & Inverters In Un -Grounded Systems Per 690.35(F) (String -systems) WARNING ELECTRICAL SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED CID AND MAY BE ENERGIZED Conduit, Ra Eve 10') 4 ;Eah,,knd,1-,B;;;j(La1eled AC Disconnect and Any Load Centers (Combiner Panel) WARNING: DUAL POWER SOURCE Pe r 690.17(E) & 70532 PHOTOVOLTAIC AC DISCONNECT SECOND SOURCE IS A PHOTOVOLTAIC SYSTEM RATED AC OUTPUT CURRENT: 14.4 A -6 RATED AC OUTPUT CURRENT: 14.4 A NOM. OPERATING AC VOLTAGE: 240 V DC Disconnect Per 690.17 WARNING ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE WARNING ELECTRICAL SHOCK HAZARD ENERGIZED IN THE OPEN POSITION DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE 0i U Ca ENERGIZED IN THE OPEN POSITION Inverter Output Connection (Solar Breaker) at C) 'Main Service Panel Per 705.12 I 4 WARNING MAIN BREAKER DE -RATED TO 175 DUE TO SOLAR C IRCUITI i MAX OF 65 AMPS PV SOURCE ALLOWED INVERTER OUTPUT CONNECTION DO NOT INCREASE MAIN BREAKER RATING z DO NOT RELOCATE THIS OVERCURRENT DEVICE z U o, Rapid Shutdown Per 690.56(C) -- I Rapid Shutdown Disconnect Per 690.12(5) Installed On AC Disconnect - z z F- . PHOTOVOLTAIC SYSTEM EQUIPPED MOM.:, "A- SHEET WITH RAPID SHUTDOWN NAME: 33 3 920 SHEET NUMBER: % ALL STICKERS DESCRIBED HER IN SHALL BE MADE OF WEATHERPROOF ADHESIVE, THEY SHALL BE REFLECTIVE, THEY SHALL CONTAIN NO SMALLER THAN 3/8"WHITE A RIAL FONT TEXT, AND HAVE A RED BACKGROUND, UNLESS OTHERWISE DEPICTED OR DESCRIBED. . ui J CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED WARNING: DUAL POWER SOURCE WARNING WARNING C, C4 9 Property of Vivint Solar SECOND SOURCE IS A PHOTOVOLTAIC SYSTEM 11� ELECTRICAL SHOCK HAZARD J��12 ELECTRICAL SHOCK HAZARD MAIN BREAKER DE -RATED TO 1- DUE TO SOLAR RATED AC OUTPUT CURRENT: *** A IF A GROUND FAULT IS INDICATED, THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE CIRCUITS NOM. OPERATING AC VOLTAGE: *** V NORMALLY GROUNDED CONDUCTORS UNGROUNDED AND MAY BE ENERGIZED C2 MAX OF —AMPS PV SOURCE ALLOWED Property of Vivint Solar MAY BE UNGROUNDED AND ENERGIZED Property of Vivint Solar 0 DO NOT INCREASE MAIN BREAKER RATING WARNING: PHOTOVOLTAIC POWER SOURCE Property of Vivint Solar CARD SHOWING ADDITIONAL POWER 5 F 13 SITE PLAN PLA 0 z Property of Vivint Solar Property of Vivint Solar WARNING SOURCE AND DISCONNECT LOCATIONS. PLACARD 10 2 Y S - INVERTER OUTPUT CONNECTION SHALL BE MOUNTED ON EXTERIOR OF ELECTRICAL �CT WARNING PHOTOVOLTAIC AC DISCONNECT C3 < ELECTRICAL SHOCK HAZARD RATED AC OUTPUT CURRENT: *** A DO NOT RELOCATE THIS OVERCURRENT DEVICE PANEL (only when necessary) DO NOT TOUCH TERMINALS. TERMINALS GIN BOTH 6 NOM. OPERATING AC VOLTAGE: — V Property of Vivint Solar Property of Vivint Solar THE LINE AND LOAD SIDES MAY BE ENERGIZED IN Property of Vivint Solar PHOTOVOLTAIC POWER SOURCE DC DISCONNECT . 11 THE OPEN POSITION PHOTOVOLTAIC SYSTEM E QUIPPED WITH RAPID RATED MAXIMUM POWER POINT CURRENT (IMP) ... A PV rapid shutdown disconnect Property of Vivint Solar 7 SHUTDOWN RATED MAXIMUM POWER POINT VOLTAGE (VMPl ... V placard indicated an E.3 Property ofVivint Solar MAXIMUM SYSTEM VOLTAGE (VOC) ... V PHOTOVOLTAIC DC DISCONNECT SHORT CIRCUIT CURRENT (ISCI ... A (13 8 Property of Vivint Solar Property of Vivint Solar 0 value calculated for each account, for specific value see the C previous warning label page 14 4 7 koom� ARRAY 8 12 6 6 6 2 4 13 IF APPLICABLE EVERY 10'AND WITHIN I'OF ELBOWS -$, 3 3 3 3 1 2 0 oa 5 5 5 5 5 5 5 0,' (D q. z MICRO -INVERTER SYSTEMS DC 'T z . t� DISCONNECT INSIDE SHEET (OR) VISIBLE/LOCKABLE VIViNT SOLAR METER VISIBLE/LOCKABLE --F-WAIN SERVICE SOLAR INVERTERS COMBINER PANEL SUB PANEL T NAME: CT, (MAY BE ON ROOFTOP (WHEN USED) A/C DISCONNECT (WHERE REQUIRED) A/C DISCONNECT WHEN REQUIRED) DISCONNECT PANEL -0 _J. 5 INTEGRATED WITH (WHERE REQUIRED) STRING -INVERTER 10 10 E ARRAY) TYPICAL SOLAR GENERATION INSTALLATION! INSIDE PANEL SYSTEMS (NOT ALL DEVICES ARE REQUIRED IN EVERY JURISDICTION) SOL SHEET NUMBER: ALL STICKERS DESCRIBED HERIN SHALL BE MADE. OF WEATHERPROOF THESE PLACARDS SHALL BE PLACED ON ALL INTERIOR AND EXTERIOR DIRECT-CURRENT (DC) CONDUIT, ENCLOSURES, RACE -WAYS, CABLE ADHESIVE, THEY SHALL BE REFLECTIVE, THEY SHALL CONTAIN NO ASSEMBLIES, JUNCTION BOXES COMBINER BOXES, AND DISCONNECTS TO ALERT THE FIRE SERVICE TO AVOID CUTTING THEM. MARKINGS SMALLER THAN 3/8"WHITE ARIAL FONT TEXT, AND HAVE A RED SHALL BE PLACED ON ALL OC CONDUIT EVERY 10 FT (3048 MM), WITHIN 1 FT (305MM) OF TURNS OR BENDS AND WITHIN 1 FT (305 MM), ABOVE -IT BACKGROUND, UNLESS OTHERWISE DEPICTED OR DESCRIBED. AND BELOW PENETRATIONS OF ROFF/CEILING ASSEMBLIES, WALLS OR BARRIERS U; -Al Vi A u j %; < Ir It'll u m It j 4 "1 't !r7 - I hii; 1 46 04 M. jiv �,it X M 3"r fl; ist 3ow 0 22-1 for Aux: z 0 7� c x E 5.1 zo� r m M ZWj!NWSTALLE�:WV,1TVIN � X ELEC. SOLAR 1 0 0 vivint. solar 5807991 RESIDENCE STA EER __I IER: 1.877.40!�� PHOTO Sr9m 47 QUAIL COVEY CT CHICO, CA 95973 [DRAWN BY: PD I S: JARRETT Last Modified: 9/8/2017 UTILITY ACCOUNT NUMBER: 78100565825 Ww\�.Iinkos ar cor� '0 -4 Edgle''',-,PERC 60' 0i.f '28 Z00-Waff oAnK0 PERC 4 I J7 Z' a I 111 M I C Positive �.\�efr',fol�ler6nce 8f 0 - �3%' KEY FEATUk ES F,000�v High Voltage l00-3Vs:andar4z!: 1500V option lowers BOS cos'.sandyields better LCOE Q20—vi It. q'r Innovative Solar Cells Four busbor cell technology improves module efficiency PID -Free L =__ Worlcl's I st PID -Free module a 185 C /857.RH, Low -Light 126'rforrinance New glass iechnology improves light absorption and retention Strength and Durability JL420L Cejtified for nig'h snow (5400PO I and wind (24GOP loods Weather Resistance Cenlified for salt mist and ammonia resistance LINEAR PERFdRMANCE WARRANTY 4. 10 Year Product Warranty 25 Year Unear Power Warranty 9110`1:2-000 Quality Standards -.ISO -,.IS014?01:2004 Environmental standards CHSAS18001 Occupational H I ealth & Safety Standards 44. 100% W Unearperforimoncewoffanty Nomenclature: 97% A hj Standard performonce warron ty 95% 'Ile r, JKM300M "Orn T J1hko S Code Fra..113..kshaet Code Collin 90% "'d I Black/White �wl 100 Bla.Wfflack V 1500V ov .2% It years CE LISTED A, Module Type JKM28OM-BD-V JKM285M-60-V JKM29OM-60-V JKM295M-60-V JKM30OM-60-V STICK_j�Wn_� C Jlli��_-770C 7_ Maximum Power (Pmax) 28OWp 209Wp 285Wp 212Wp 29OWp 216Wp 295Wp 224Wp 30OWp 227ft V -_221�� ;�j 32.2 Maximum Power Current (Imp) BAIA T.01A 8.9A 7 12A 9,02A 7 15A 9.1A 7,32A 9.3A 7.4A Short-circuit Current (Isc) 9.49A 7,62A 9.51A 7.72A 9.55A 7,81A 9.61 A 8.01A 9.B3A 8.12A 117.72% WN Operating Temperature(C) AO'C-85C Maximum system voltage 1500VOC(UL)i Maximum sed'es fuse rating 5A Power tolerance 0-21% & Temperature coefficients of Pinax -0.39%rC Temperattirecoe4icient�_&Voc Temperature coefficients of Isc 0.05%rc ing cell temperature (NO Nom�ZlTperA 'CT) .3. 45t2 It Cell Temperature 25'C ST�: Irradiance 100OW/m, A' NOCT: :i Irradiance � OW/m2 Wind Spe 80 Ambient Temperature 20'C AM=1.5 ed 1 m/s Power measurement tolerance: t 3% CAUT ION. READ SAFETY AND INSTALI.ATION INSTRUCTIONS BEFORE USING THE PRODUCT. (ON Jinko Solar Ca_ Ltd. All rights reserved specifications included in this datasheet are subject to chance without notice. US-MKT-300M-60-V_vl..0,_rev2017 gineer rawings g Q9212— 129 061 4G—, f W 7 1 1147 0.­� (3 109, 1 CLIMnt-Volrage&P mr-VolLige Tomperatum Dapende C- (290.4 "C' 7 t 1111 v.C. r J. veduq., V; ell 1- ... ..... K"'� Mechanical 6aracteristic-s, Cell Type Mono-crystalOe PERC 156x ��61nin'(6 inch) Nn nf rplk 60 (6. 10) Dimcnsions 1650-992,40min (G4.97�39.06- 1,57 int:11) Weight 19.0 kq (41 9 lbs.) Front Glass 3.Zmm, HIgh Transtnisslon, Low Iron, AR Coating -Tempered Glass Packagiriy Confiyuratiotis Frame Anodized Aluminium Alloy Junction Box IP67 Rated 26pcs/ Uox . 52pcs/pallet, 728 pcs/40'.HQ Container Output Cables 12 AWG, Length:900mm (35.43 inchl Fire rype 'Type 1 -0 Module Type JKM28OM-BD-V JKM285M-60-V JKM29OM-60-V JKM295M-60-V JKM30OM-60-V STICK_j�Wn_� C Jlli��_-770C 7_ Maximum Power (Pmax) 28OWp 209Wp 285Wp 212Wp 29OWp 216Wp 295Wp 224Wp 30OWp 227ft V -_221�� ;�j 32.2 Maximum Power Current (Imp) BAIA T.01A 8.9A 7 12A 9,02A 7 15A 9.1A 7,32A 9.3A 7.4A Short-circuit Current (Isc) 9.49A 7,62A 9.51A 7.72A 9.55A 7,81A 9.61 A 8.01A 9.B3A 8.12A 117.72% WN Operating Temperature(C) AO'C-85C Maximum system voltage 1500VOC(UL)i Maximum sed'es fuse rating 5A Power tolerance 0-21% & Temperature coefficients of Pinax -0.39%rC Temperattirecoe4icient�_&Voc Temperature coefficients of Isc 0.05%rc ing cell temperature (NO Nom�ZlTperA 'CT) .3. 45t2 It Cell Temperature 25'C ST�: Irradiance 100OW/m, A' NOCT: :i Irradiance � OW/m2 Wind Spe 80 Ambient Temperature 20'C AM=1.5 ed 1 m/s Power measurement tolerance: t 3% CAUT ION. READ SAFETY AND INSTALI.ATION INSTRUCTIONS BEFORE USING THE PRODUCT. (ON Jinko Solar Ca_ Ltd. All rights reserved specifications included in this datasheet are subject to chance without notice. US-MKT-300M-60-V_vl..0,_rev2017 _6 i Enphaso Microinv_-'arler S Enphase IQ 6 and IQ 6+ Microinverters To learn more about Enphase offerings, visit enphase.com Designed for higher powered modules, the smart grid - ready Enphase IQ 6 Micro" and Enphase IQ 6+ Micro'm are built on the sixth -generation platform and achieve the highest efficiency for module -level power electronics and reduced cost per watt. Part of the Enphase IQ System, the IQ 6 and IQ 6+ Micro integrate seamlessly with the Enph 3se IQ Envoy', Enphase IQ Battery", and the Enphase Enlighten' monitoring and analysis software. The IQ 6 and IQ 6+ Micro are very reliable as they have fewer parts and undergo over 1 mikion hours of testing. Enphase provides an industry-leading warranty of up to' 25 years. Easy to Install Lightweight Simple cable management Built-in rapid shutdown (NEC 2014) Productive Optimized for high powered modules Supports 60 and 72 -cell modules Maximizes energy production Smart Grid Ready Complies with fixed power factor, voltage 3nd frequency ride -through requirements Remotely updates to respond to changingi grid requirements Configurable for varying grid profiles Enphase IQ 6 and IQ 6+ Microinverters INPUT DATA (DC) -6 ' IQ6-60-2-US AND 106 -60 -5 -US 106PLUS-72-2-US AND IQ6PLUS-72-5-US ommonly is,� morfule pairings' 'I 4�,W .-330 W + 235 W - 400 W + Module compatibility 60 -c -,?Il PV modules oniy 60 -cell -dod 72-ce.11 PV mudulLs Maximum input DC voltage 48 V 62 V Peak power tracking voltage 2/V -37V 2/V -45V Operating range 16 V - 48 V 16 V - 62 V Min/Max startjoltage 22 V / 48 V 22 V / 62 V Max DC shurt L:irr;uit current (module Isc) 15A 15 A Overvoltage class DC port 11 11 6 DC port backfeed under single fault 0 A 0 A PV array configuration 1 x I unqrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ6-60-2-US AND IQ6-60-5-US IQ6PLUS-72-2-US AND 106PLUS-72-5-US Peak output power 240 VA 290 VA Maximum continuous output power 230 VA 280 VA Nominal voltage/range2 240 V / 211-264 V 208 V (10) 1183-229 V 240 V / 211-264 V 208 V (10) 183-229 V Nominal output current 0.96 A 1.11 A IJ 7 A 1.35 A Nominal frequency 60 Hz 60 Hz ExItended fieque!iuy imiye 47- 68 Hz 47 - 68 Hz Power factor at raledPower 1.0 1.0 Maximum units per 20 A branch circuit 16 (240 VAC) 13 (240 VAC) 14 (single-phase 208 VAC) 11 (single-phase 208 VAC) Ovcrvoltage class AC port III III AC port backfeed under single fault 0 A 0 A Power factor (adjustable) 0.7 leading,, . 03 lagging 0.7 leading— 0.7 lagging, EFFICIENCY @240 V @208 V (10) @240 V @208 V (14)) CEC weighted efficiency 97.0% 96.5% 97,0% 96.5% - MECHANICAL DATA .Ambient.temperature-range- �40OC-to.+650C Relative humidity range 4% to 100% (condensing) Connector type MC4 or Arriphenol'H4 LITX Dimensions (WxHxD) 219 mm x 191 mm x 37.9 rnm (without bracket) Weight 1.5 kg (3.3 lbs) Cooling Natural convection - No fans Approved for wet locations Yes Pollution degree PD3 Environmental category UV exposure rating: Outdoor - NEMA 250, type,6 (IP67.) FEATURES Communication 'Power line Monitoring Enlighten Manager and MyEnlighten monitoring options Compatible with Enphase IQ Envoy Compliance! L62109 --T UL-174T/IEEE1547, FCC Part 15�01ass.Bi -ICES�000 dass�Elj: U CAN/CSA-,C22..2 NO. 1 G7.1-01 This product is UL Listed a t Down:Equipment an �h' ----2- .4s.PV k'pid1§ku` 6'conforms.wit NEC G14'and, NE&4017'section!69012 and.C22,.1-2015,Rule 64�218 RApid,Shittdowwof PV Systerns,,forAC: and DC candUCtOFS, when installed according manufacturer's -instructions. 1. No enforced DC/AC ratio. See the compatibility calculator at ennhase.com/eii-us/suaporlimodul�-comoatibilit 2. Nominal voltage range can be extended beyond nominal if required by the utility, To learn more about Enphase offerings, visit enphase.com ID ,,, 2017 E.9phase Energy. Ail rights reserved. All tf3demarks c, brands used are the pioperty of EnPhase Energy, Inc, ENPHASE. 2017-03-1- 5 %—Of